========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0057 Injection acquisition : SIG0058 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -5.43444104e-03 0.00000000e+00 5.43444104e-03 3.14159265 0.00563264 0.25 -4.65465320e-03 6.51795300e-04 4.70006739e-03 3.00246640 0.00454096 0.50 1.16302882e-02 -1.38614316e-02 1.80942778e-02 -0.87269993 0.12702069 0.75 4.88405943e-03 -7.24962159e-03 8.74134141e-03 -0.97794129 0.02899321 1.00 -1.56284744e-03 -1.34400547e-02 1.35306157e-02 -1.68655924 0.04886281 1.25 3.98451828e-03 -8.12012989e-03 9.04504811e-03 -1.11461928 0.02976355 1.50 2.82983936e-03 -5.09218362e-03 5.82566089e-03 -1.06357051 0.00820805 1.75 7.95809184e-04 -8.75595246e-03 8.79204275e-03 -1.48015756 0.02004315 2.00 4.84336424e-03 -1.31141170e-02 1.39799228e-02 -1.21701073 0.03492294 2.25 4.31784436e-03 -9.12485892e-03 1.00948913e-02 -1.12882113 0.02892420 2.50 7.76969605e-03 -9.25747110e-03 1.20858987e-02 -0.87255336 0.03094011 2.75 5.73033048e-03 -8.87701534e-03 1.05658927e-02 -0.99757380 0.03395782 3.00 4.44777792e-03 -1.06064497e-02 1.15012827e-02 -1.17372395 0.03707313 3.25 2.84336830e-03 -1.12778169e-02 1.16307307e-02 -1.32382294 0.04712300 3.50 1.83928177e-03 -1.09021411e-02 1.10562035e-02 -1.40366185 0.04348610 3.75 4.07359384e-03 -1.31717366e-02 1.37872699e-02 -1.27085881 0.06908429 4.00 4.09242091e-03 -1.28397729e-02 1.34761892e-02 -1.26224583 0.05600890 4.25 -2.20718989e-04 -1.59503491e-02 1.59518762e-02 -1.58463332 0.06079583 4.50 -1.37570065e-03 -1.61048690e-02 1.61635194e-02 -1.65601088 0.05622445 4.75 2.13049708e-03 -1.54089806e-02 1.55555682e-02 -1.43340407 0.04396182 5.00 2.10061271e-03 -1.66170427e-02 1.67492890e-02 -1.44505017 0.04777509 5.25 -1.00305955e-03 -1.25345079e-02 1.25745781e-02 -1.65065001 0.01951020 5.50 5.52983467e-04 -1.14524085e-02 1.14657512e-02 -1.52254846 0.01616619 5.75 -6.27270282e-04 -2.20967629e-02 2.21056644e-02 -1.59917613 0.06169838 6.00 1.45505236e-03 -2.53340188e-02 2.53757696e-02 -1.51342463 0.06887623 6.25 2.06993226e-03 -2.01027739e-02 2.02090607e-02 -1.46819043 0.05937658 6.50 2.75486864e-03 -2.13342733e-02 2.15114044e-02 -1.44237816 0.05561974 6.75 1.71561868e-03 -1.52013610e-02 1.52978666e-02 -1.45841233 0.03071477 7.00 -8.06136988e-04 -1.85509985e-02 1.85685057e-02 -1.61422419 0.04516929 7.25 5.19952798e-03 -2.42049036e-02 2.47570686e-02 -1.35919891 0.07322908 7.50 2.51354870e-03 -2.63981720e-02 2.65175680e-02 -1.47586575 0.08258991 7.75 1.17167704e-03 -2.93459112e-02 2.93692924e-02 -1.53089111 0.09796086 8.00 5.68967089e-04 -2.80603502e-02 2.80661180e-02 -1.55052256 0.08845621 8.25 5.43205081e-04 -2.51013838e-02 2.51072607e-02 -1.54915926 0.07106991 8.50 2.09336706e-03 -2.65902955e-02 2.66725702e-02 -1.49223164 0.06856628 8.75 3.43075596e-03 -2.64836642e-02 2.67049537e-02 -1.44197140 0.05171191 9.00 4.50773972e-03 -2.78186341e-02 2.81814854e-02 -1.41015233 0.06101094 9.25 4.32268907e-03 -3.06166276e-02 3.09202769e-02 -1.43053578 0.05798303 9.50 2.35340141e-03 -3.34085596e-02 3.34913475e-02 -1.50046943 0.06857235 9.75 7.82239832e-03 -3.07621344e-02 3.17411220e-02 -1.32178731 0.04920672 10.00 4.82474350e-03 -3.33278659e-02 3.36752847e-02 -1.42702905 0.07160567 10.25 -7.57223912e-03 -3.26023699e-02 3.34701857e-02 -1.79901047 0.07112294 10.50 -2.17775664e-03 -3.78012904e-02 3.78639694e-02 -1.62834336 0.09617725 10.75 -9.51712107e-04 -4.69413441e-02 4.69509908e-02 -1.59106805 0.15574024 11.00 -7.31349734e-04 -3.84004743e-02 3.84074381e-02 -1.58983936 0.08702511 11.25 -1.96281237e-03 -3.37189083e-02 3.37759886e-02 -1.62894174 0.05746869 11.50 8.67771107e-04 -4.49238794e-02 4.49322598e-02 -1.55148225 0.10904787 11.75 -5.47405017e-03 -4.68689375e-02 4.71875251e-02 -1.68706441 0.12279544 12.00 7.90622284e-03 -4.67396916e-02 4.74036616e-02 -1.40322817 0.11985481 12.25 1.53273448e-02 -3.65542595e-02 3.96376258e-02 -1.17376017 0.08607052 12.50 -2.82962839e-03 -3.58870129e-02 3.59983956e-02 -1.64948179 0.05310335 12.75 -1.31729085e-02 -4.51019513e-02 4.69862909e-02 -1.85496173 0.08053288 13.00 -8.38631103e-04 -4.72450659e-02 4.72525084e-02 -1.58854512 0.06807163 13.25 2.61505354e-04 -4.76477874e-02 4.76485050e-02 -1.56530808 0.06031079 13.50 -1.47448032e-02 -4.98118832e-02 5.19483679e-02 -1.85858833 0.06042973 13.75 -2.48142573e-02 -5.63330490e-02 6.15561514e-02 -1.98571532 0.06949012 14.00 4.87396872e-02 -5.01570030e-02 6.99377012e-02 -0.79972846 0.06712624 14.25 5.43980496e-02 -3.84638387e-02 6.66229292e-02 -0.61546266 0.05090491 14.50 3.48701994e-02 -5.04181236e-02 6.13018596e-02 -0.96571647 0.06368796 14.75 4.69564261e-02 -5.17943086e-02 6.99110603e-02 -0.83434988 0.07920187 15.00 1.95166961e-02 -6.40616795e-02 6.69686509e-02 -1.27507459 0.07086644 15.25 2.45230285e-02 -6.76789107e-02 7.19848170e-02 -1.22316747 0.08224113 15.50 4.22506299e-02 -3.45727858e-02 5.45929780e-02 -0.68578747 0.03986716 15.75 4.38437079e-02 -2.57530966e-02 5.08477404e-02 -0.53109145 0.03648336 16.00 7.44028123e-03 -7.40374953e-02 7.44104059e-02 -1.47063916 0.10103097 16.25 1.54868045e-03 -7.94334562e-02 7.94485517e-02 -1.55130222 0.11325955 16.50 1.46315298e-02 -7.20901402e-02 7.35599754e-02 -1.37055471 0.09007878 16.75 8.51571318e-03 -6.57628606e-02 6.63119235e-02 -1.44202168 0.07261850 17.00 1.89138469e-02 -2.31144617e-02 2.98665690e-02 -0.88501461 0.01370374 17.25 1.16914987e-02 -2.70868412e-02 2.95023407e-02 -1.16332327 0.01372904 17.50 2.26510718e-02 -4.58352982e-02 5.11267603e-02 -1.11181232 0.04774037 17.75 1.74412065e-02 -5.29093984e-02 5.57099643e-02 -1.25237085 0.05212515 18.00 4.28453034e-02 -8.67134588e-02 9.67209592e-02 -1.11187815 0.11883788 18.25 3.89357687e-02 -6.85821175e-02 7.88638125e-02 -1.05444674 0.09077158 18.50 3.55878846e-02 -5.77569707e-02 6.78407341e-02 -1.01857475 0.06263919 18.75 3.01152777e-02 -5.55192668e-02 6.31610556e-02 -1.07378412 0.05765606 19.00 2.85426451e-02 -2.91723424e-04 2.85441358e-02 -0.01022026 0.01110091 19.25 2.07412378e-02 -3.79575485e-02 4.32547620e-02 -1.07069621 0.02377459 19.50 4.76122885e-03 -8.81063750e-02 8.82349285e-02 -1.51680929 0.07487141 19.75 1.26894990e-02 -8.71817627e-02 8.81004150e-02 -1.42625910 0.08464115 20.00 -1.13726218e-02 -6.83903712e-02 6.93294988e-02 -1.73557831 0.04897060 20.25 1.79997768e-02 -7.70972468e-02 7.91705591e-02 -1.34143623 0.06231246 20.50 5.16748761e-02 -8.95389540e-02 1.03380448e-01 -1.04736897 0.07874784 20.75 3.35069733e-02 -9.14827554e-02 9.74259298e-02 -1.21970524 0.09456298 21.00 5.49693814e-02 -9.21394500e-02 1.07290778e-01 -1.03288870 0.08382721 21.25 9.22601141e-03 -6.00618536e-02 6.07663191e-02 -1.41837916 0.03594647 21.50 -9.89913131e-03 -4.60788245e-03 1.09190376e-02 -2.70593750 0.00131048 21.75 4.41111073e-02 -7.75703295e-02 8.92353394e-02 -1.05374013 0.06453618 22.00 1.04741833e-01 -9.29468054e-02 1.40035568e-01 -0.72580414 0.11484777 22.25 5.07633841e-02 -1.00326184e-01 1.12437825e-01 -1.10237346 0.08522457 22.50 1.11257446e-01 -1.36130196e-01 1.75811403e-01 -0.88560303 0.15142299 22.75 6.80089198e-02 -8.85152295e-02 1.11625082e-01 -0.91566676 0.06369635 23.00 1.00572249e-01 -7.06922446e-02 1.22931569e-01 -0.61266969 0.06782575 23.25 1.05172519e-01 -5.71417393e-02 1.19693096e-01 -0.49769579 0.08554164 23.50 9.92351269e-02 -4.65086463e-02 1.09593178e-01 -0.43827196 0.07818866 23.75 7.95537909e-02 -2.92009128e-02 8.47437251e-02 -0.35179034 0.04449783 24.00 1.46604289e-01 -4.75935369e-03 1.46681522e-01 -0.03245255 0.08532335 24.25 1.47165575e-01 -3.21320754e-02 1.50632589e-01 -0.21496602 0.09898225 24.50 1.71916149e-01 -3.77524024e-02 1.76012517e-01 -0.21616661 0.10352296 24.75 9.10652211e-02 -5.37986271e-02 1.05769404e-01 -0.53360531 0.03859078 25.00 8.10217457e-02 -3.68153164e-02 8.89937683e-02 -0.42649707 0.03374002 25.25 6.63429429e-02 -5.91172697e-02 8.88607768e-02 -0.72786837 0.04893854 25.50 7.25612222e-02 -3.49248000e-02 8.05287068e-02 -0.44858813 0.03309831 25.75 8.16035932e-02 -1.84188831e-02 8.36564503e-02 -0.22199171 0.03102457 26.00 5.02721919e-02 -5.40196082e-02 7.37930305e-02 -0.82131474 0.02470464 26.25 5.34472928e-02 -8.45062276e-02 9.99895775e-02 -1.00684640 0.07610090 26.50 4.59940970e-02 -8.80837082e-02 9.93689922e-02 -1.08957554 0.07845352 26.75 1.61056466e-02 -7.60697615e-02 7.77560317e-02 -1.36215538 0.05805779 27.00 1.12512313e-02 -8.27416179e-02 8.35030870e-02 -1.43564496 0.06194464 27.25 6.68942635e-03 -6.03183508e-02 6.06881526e-02 -1.46034566 0.03467433 27.50 1.05806384e-02 -6.20527065e-02 6.29482986e-02 -1.40191004 0.03660762 27.75 5.61485035e-02 -5.63633033e-02 7.95580065e-02 -0.78730729 0.05058308 28.00 4.15136863e-02 -6.85975491e-02 8.01811069e-02 -1.02657861 0.04790029 28.25 5.93167179e-02 -5.68040549e-02 8.21290063e-02 -0.76376318 0.05896654 28.50 3.69838804e-02 -6.82718710e-02 7.76457068e-02 -1.07433639 0.05112749 28.75 3.34955698e-02 -5.40015975e-02 6.35462487e-02 -1.01560561 0.02728155 29.00 2.41197799e-02 -6.13328064e-02 6.59050599e-02 -1.19611319 0.03282456 29.25 3.77459009e-02 -6.78382384e-02 7.76323362e-02 -1.06304483 0.04204550 29.50 1.93221115e-02 -6.35869511e-02 6.64578388e-02 -1.27579366 0.03236701 29.75 3.44860431e-03 -3.00136272e-02 3.02111021e-02 -1.45639673 0.00569459 30.00 1.27035867e-02 -5.00889171e-02 5.16747591e-02 -1.32241285 0.01845562 30.25 -7.15769088e-03 -8.65858992e-02 8.68812435e-02 -1.65327457 0.04449390 30.50 4.13204667e-02 -5.06289723e-02 6.53503925e-02 -0.88628948 0.02612679 30.75 4.30018732e-02 -3.63087428e-03 4.31548879e-02 -0.08423546 0.00975521 31.00 1.11175829e-02 -3.14589975e-02 3.33656886e-02 -1.23109653 0.00612843 31.25 2.31460632e-02 -2.23744206e-04 2.31471446e-02 -0.00966632 0.00194535 31.50 2.28029342e-02 -4.52316608e-02 5.06544859e-02 -1.10384494 0.01258577 31.75 1.12379300e-02 -4.93425216e-02 5.06060817e-02 -1.34686265 0.01116041 32.00 -4.47105333e-02 -6.49764948e-02 7.88731682e-02 -2.17349315 0.02673014 32.25 -3.30842226e-02 -3.26325624e-02 4.64698817e-02 -2.36306721 0.00692930 32.50 -3.14407758e-02 -9.33235256e-02 9.84774229e-02 -1.89575421 0.02983578 32.75 3.40442711e-03 -1.00512330e-01 1.00569969e-01 -1.53693853 0.02096104 33.00 2.46645326e-03 -8.03998443e-02 8.04376675e-02 -1.54012861 0.01978136 33.25 2.60933359e-02 -8.55168358e-02 8.94091236e-02 -1.27464423 0.02664911 33.50 6.29103648e-02 -1.02751008e-01 1.20480221e-01 -1.02141063 0.05165977 33.75 4.85031454e-02 -7.28815357e-02 8.75458357e-02 -0.98359725 0.02486098 34.00 2.01374714e-02 -1.44204845e-02 2.47682888e-02 -0.62145116 0.00241888 34.25 -5.54319307e-02 8.04757669e-03 5.60130559e-02 2.99742049 0.01182279 34.50 -8.68084478e-02 -7.99081280e-03 8.71754535e-02 -3.04980024 0.02799727 34.75 -6.07898886e-02 -3.51802503e-02 7.02357499e-02 -2.61696810 0.01453634 35.00 -5.94730412e-02 -2.31219399e-02 6.38096132e-02 -2.77079579 0.00942728 35.25 -1.02283269e-01 8.86851438e-02 1.35376962e-01 2.42728066 0.04032553 35.50 -1.20582444e-01 -7.21933398e-02 1.40541823e-01 -2.60212573 0.05726152 35.75 -1.17222207e-01 -1.67902609e-01 2.04773855e-01 -2.18028361 0.12250944 36.00 -4.45729513e-02 -2.53220149e-01 2.57113189e-01 -1.74503588 0.18015507 36.25 1.23961047e-02 -4.15206605e-01 4.15391609e-01 -1.54094992 0.35291395 36.50 8.32408771e-02 -4.28391408e-01 4.36403761e-01 -1.37887754 0.34732212 36.75 2.50794974e-02 -2.60312751e-01 2.61518087e-01 -1.47474905 0.14054746 37.00 1.53321756e-02 1.08026115e-01 1.09108740e-01 1.42980773 0.02264631 37.25 -2.05247691e-02 1.17733073e-01 1.19508755e-01 1.74339482 0.03287059 37.50 -7.81576805e-02 -2.62132006e-02 8.24363689e-02 -2.81799344 0.01215899 37.75 9.15312622e-03 -2.51981183e-02 2.68090448e-02 -1.22236977 0.00116212 38.00 7.12520101e-02 5.52086171e-02 9.01378963e-02 0.65920755 0.01567354 38.25 6.48832442e-02 2.86153330e-02 7.09131347e-02 0.41536788 0.01116129 38.50 -5.25791038e-02 1.37296755e-01 1.47020275e-01 1.93652691 0.04052824 38.75 -4.87046395e-02 4.95548321e-02 6.94825395e-02 2.34754218 0.00908109 39.00 6.63738015e-02 3.08262254e-02 7.31829058e-02 0.43479189 0.00972988 39.25 4.96270238e-02 1.91897269e-02 5.32079609e-02 0.36897026 0.00547069 39.50 3.36985986e-03 2.07413706e-02 2.10133388e-02 1.40973321 0.00068020 39.75 2.38881540e-03 1.76308980e-02 1.77919927e-02 1.43612612 0.00067067 40.00 -2.03929095e-02 5.61458803e-02 5.97346686e-02 1.91919329 0.00984447 40.25 -1.23674389e-02 2.00569080e-02 2.35633848e-02 2.12334500 0.00152119 40.50 -4.30966933e-02 -6.78704367e-02 8.03972708e-02 -2.13654350 0.01423151 40.75 1.77778526e-03 -6.04816424e-02 6.05077647e-02 -1.54141099 0.00830270 41.00 -8.07016479e-03 -9.03317577e-02 9.06915322e-02 -1.65989895 0.01871357 41.25 -3.21904845e-04 -1.43531202e-01 1.43531563e-01 -1.57303907 0.05779523 41.50 9.03701525e-02 -1.14943961e-01 1.46215179e-01 -0.90452034 0.04723301 41.75 4.81888717e-02 -6.78926939e-02 8.32561423e-02 -0.95353676 0.01893869 42.00 1.03581688e-02 -3.46140864e-02 3.61306883e-02 -1.28003031 0.00292875 42.25 6.52010920e-02 1.61496375e-03 6.52210894e-02 0.02476390 0.01221835 42.50 2.20715356e-02 1.24646811e-01 1.26585861e-01 1.39554035 0.04970614 42.75 -3.19253819e-04 1.67800328e-01 1.67800631e-01 1.57269891 0.07387649 43.00 -5.88095583e-03 2.41997659e-01 2.42069107e-01 1.59509325 0.15958787 43.25 -1.51129256e-02 1.41474913e-01 1.42279835e-01 1.67721682 0.06647259 43.50 -4.02089143e-02 1.28181246e-01 1.34339825e-01 1.87476310 0.06581825 43.75 -5.77898654e-02 4.51742274e-02 7.33510692e-02 2.47811147 0.02598172 44.00 -4.37550436e-02 5.66478661e-02 7.15785203e-02 2.22848255 0.02963469 44.25 -1.00753671e-01 5.80342899e-02 1.16272443e-01 2.61900586 0.09304675 44.50 -1.13150250e-01 8.49848542e-02 1.41511146e-01 2.49740090 0.17480453 44.75 -1.63476642e-01 4.25259843e-02 1.68917352e-01 2.88709822 0.28830803 45.00 -2.05487112e-01 8.97934060e-03 2.05683208e-01 3.09792261 0.38170586 45.25 -2.37771791e-01 -9.30769183e-02 2.55340434e-01 -2.76847443 0.32545871 45.50 -2.10844031e-01 -8.71459243e-02 2.28143853e-01 -2.74965705 0.24305003 45.75 -1.25535142e-01 -2.72878154e-02 1.28466715e-01 -2.92755048 0.06543160 46.00 -1.23521329e-01 -9.66122117e-03 1.23898579e-01 -3.06353656 0.07156556 46.25 -3.40441828e-02 -1.40306913e-01 1.44378102e-01 -1.80883679 0.14118249 46.50 -2.15270509e-02 -2.05281373e-01 2.06407016e-01 -1.67528051 0.28003224 46.75 9.75301326e-03 -2.42046796e-01 2.42243210e-01 -1.53052420 0.23087710 47.00 3.88851509e-02 -2.73340343e-01 2.76092373e-01 -1.42948540 0.21229123 47.25 -6.09742666e-02 -1.64328640e-01 1.75276248e-01 -1.92610016 0.07222442 47.50 -7.73233273e-02 -1.42701410e-01 1.62304003e-01 -2.06736389 0.06679640 47.75 -8.11230693e-02 -1.56502427e-01 1.76278082e-01 -2.04901612 0.06727742 48.00 -7.26174270e-02 -1.62474875e-01 1.77964535e-01 -1.99110729 0.05748135 48.25 -1.37171209e-01 -5.42249952e-02 1.47500137e-01 -2.76513689 0.03188135 48.50 -2.80887599e-01 -6.40917397e-02 2.88106915e-01 -2.91725755 0.08698883 48.75 -5.12553979e-01 -3.80107277e-02 5.13961474e-01 -3.06756869 0.25743132 49.00 -5.55262077e-01 -2.92026872e-02 5.56029469e-01 -3.08904844 0.22653209 49.25 -1.15451937e+00 -2.99290721e-01 1.19268182e+00 -2.88794219 0.39180037 49.50 -1.42081267e+00 -3.48152949e-01 1.46284623e+00 -2.90128963 0.39783110 49.75 -2.46800190e+00 1.54722009e+00 2.91288918e+00 2.58161957 0.44454009 50.00 -1.44021816e+00 1.97651058e+00 2.44557200e+00 2.20050398 0.38758962 50.25 -4.79353116e-01 1.21497900e+00 1.30612151e+00 1.94658362 0.48713152 50.50 -4.92190911e-01 5.92025997e-01 7.69900432e-01 2.26437306 0.34261662 50.75 -3.98072341e-01 4.87453769e-02 4.01045758e-01 3.01974570 0.18220751 51.00 -3.11474683e-01 -6.27849951e-02 3.17739569e-01 -2.94268472 0.10513384 51.25 -5.24632451e-01 3.97103998e-03 5.24647480e-01 3.13402361 0.24555953 51.50 -5.34459069e-01 -7.13161531e-02 5.39196152e-01 -3.00894012 0.23780364 51.75 -5.29114722e-01 -1.39074268e-01 5.47086868e-01 -2.88456317 0.19728617 52.00 -3.62793663e-01 -1.67707226e-01 3.99681067e-01 -2.70858515 0.11782325 52.25 -5.26688886e-01 -1.57344765e-01 5.49689510e-01 -2.85128921 0.14369429 52.50 -4.31550511e-01 -2.94470661e-02 4.32554012e-01 -3.07346276 0.18998092 52.75 -4.49349676e-01 1.56167047e-02 4.49620966e-01 3.10685262 0.34860105 53.00 -3.16394903e-01 -2.28321517e-01 3.90174896e-01 -2.51649389 0.31310412 53.25 -3.08037074e-01 -3.86522076e-01 4.94253127e-01 -2.24367206 0.38386585 53.50 -9.30211404e-03 -3.80658366e-01 3.80772006e-01 -1.59522837 0.17182886 53.75 1.75697789e-01 -1.78817587e-01 2.50689933e-01 -0.79419811 0.06146122 54.00 -9.50369080e-02 2.48163783e-01 2.65739115e-01 1.93652767 0.06450380 54.25 -2.52937657e-01 4.68009866e-01 5.31987493e-01 2.06628078 0.28457322 54.50 -3.86855369e-01 2.08964425e-01 4.39685350e-01 2.64633426 0.41981109 54.75 -4.08332203e-01 1.13674589e-01 4.23859765e-01 2.87007983 0.52501592 55.00 -4.36829475e-01 1.81734329e-02 4.37207347e-01 3.10001359 0.37057873 55.25 -5.62059482e-01 -6.41324901e-02 5.65706494e-01 -3.02798133 0.49956506 55.50 -5.27806774e-01 -2.80555666e-01 5.97738632e-01 -2.65302480 0.50651096 55.75 -5.57450427e-01 -3.30163244e-01 6.47887912e-01 -2.60687360 0.59760442 56.00 -4.24117866e-01 -3.94738246e-01 5.79391273e-01 -2.39205796 0.31710203 56.25 -3.70485016e-01 -5.57115849e-01 6.69056961e-01 -2.15764790 0.28856501 56.50 -5.19976856e-01 -3.43842788e-01 6.23380938e-01 -2.55733860 0.24288466 56.75 -5.00302477e-01 -3.37374687e-01 6.03427086e-01 -2.54829556 0.21225097 57.00 -3.50985925e-01 3.60074195e-02 3.52828079e-01 3.03936095 0.08969614 57.25 -3.51091087e-01 1.02854588e-01 3.65846986e-01 2.85660980 0.09128015 57.50 -7.11036446e-02 1.73414595e-01 1.87425585e-01 1.95991163 0.02965294 57.75 -3.81057295e-02 2.22610693e-01 2.25848549e-01 1.74032976 0.03933677 58.00 3.04819512e-01 3.96924707e-01 5.00463942e-01 0.91590397 0.14889792 58.25 5.97321932e-01 3.42273344e-01 6.88436295e-01 0.52033986 0.23677829 58.50 1.18311823e+00 1.99509981e-01 1.19982206e+00 0.16705896 0.59237116 58.75 1.47116739e+00 1.65701848e-02 1.47126071e+00 0.01126281 0.58296565 59.00 2.36846452e+00 -6.98176312e-01 2.46922546e+00 -0.28666108 0.65620527 59.25 1.97190557e+00 -9.30193631e-01 2.18029167e+00 -0.44077138 0.45612615 59.50 8.12726886e-01 -1.92202696e+00 2.08679482e+00 -1.17074913 0.37002078 59.75 3.85229561e-01 -1.77316711e+00 1.81453119e+00 -1.35686573 0.30309768 60.00 -4.47093076e-01 -1.76356085e+00 1.81935129e+00 -1.81908258 0.31208510 60.25 -1.78918684e-01 -1.24030951e+00 1.25314787e+00 -1.71406130 0.22434188 60.50 -1.18040148e-01 -9.85893470e-01 9.92934747e-01 -1.68995820 0.17716408 60.75 -2.57469919e-01 -3.35946574e-01 4.23262164e-01 -2.22471195 0.05197589 61.00 -6.03415641e-01 3.16981245e-02 6.04247638e-01 3.08910973 0.13857938 61.25 -3.99314750e-01 -3.73052727e-01 5.46461899e-01 -2.39018337 0.11968870 61.50 -4.50384907e-01 -2.37438652e-01 5.09140135e-01 -2.65642999 0.06728346 61.75 -5.39514655e-01 -1.93467848e-01 5.73154317e-01 -2.79728046 0.10118800 62.00 -8.97162022e-01 2.87184724e-02 8.97621549e-01 3.10959323 0.26805977 62.25 -6.08931165e-01 -1.85174273e-01 6.36464198e-01 -2.84638120 0.15993627 62.50 -9.15267852e-01 -3.18318153e-01 9.69041634e-01 -2.80689079 0.28392501 62.75 -8.84732270e-01 -1.85030248e-01 9.03873543e-01 -2.93542716 0.30513345 63.00 -1.03843059e+00 -1.57773961e-01 1.05034790e+00 -2.99081082 0.38443996 63.25 -1.01247743e+00 -7.28730455e-02 1.01509656e+00 -3.06974157 0.38394666 63.50 -1.27835271e+00 8.84610702e-02 1.28140978e+00 3.07250352 0.56909927 63.75 -1.06927680e+00 -1.62985862e-01 1.08162714e+00 -2.99033069 0.55603080 64.00 -1.30076208e+00 -2.40605628e-01 1.32282768e+00 -2.95868717 0.67566870 64.25 -1.17772887e+00 -2.88572391e-01 1.21256724e+00 -2.90130230 0.57796010 64.50 -1.33655009e+00 -4.50017517e-01 1.41027725e+00 -2.81681443 0.63522881 64.75 -1.05635746e+00 -3.21769750e-01 1.10427662e+00 -2.84591821 0.47352607 65.00 -1.13895697e+00 -2.91065750e-01 1.17556040e+00 -2.89139296 0.51378112 65.25 -9.69130181e-01 -1.41102195e-01 9.79348323e-01 -2.99701183 0.42761373 65.50 -9.99229549e-01 -1.99293565e-01 1.01891001e+00 -2.94472866 0.47228412 65.75 -9.69959022e-01 -2.01104891e-01 9.90587544e-01 -2.93715580 0.41763371 66.00 -1.25959460e+00 -1.65671991e-01 1.27044314e+00 -3.01081531 0.49669614 66.25 -1.07850935e+00 -5.59638325e-02 1.07996036e+00 -3.08974917 0.36653320 66.50 -1.12860475e+00 5.59490389e-02 1.12999069e+00 3.09205957 0.40771706 66.75 -1.03173877e+00 -1.83779755e-01 1.04797896e+00 -2.96531526 0.31031241 67.00 -1.01382755e+00 -3.12001511e-01 1.06075032e+00 -2.84304455 0.29487955 67.25 -8.48669117e-01 2.94595770e-02 8.49180273e-01 3.10689391 0.21662080 67.50 -1.15746430e+00 2.29541256e-01 1.18000542e+00 2.94581887 0.36144398 67.75 -1.45360301e+00 4.16866024e-01 1.51219674e+00 2.86230687 0.63758698 68.00 -1.72831451e+00 5.56756446e-01 1.81577774e+00 2.82995116 0.64584629 68.25 -2.47105862e+00 1.57117160e+00 2.92826073e+00 2.57524381 0.70977920 68.50 -2.09252635e+00 1.94972006e+00 2.86008301e+00 2.39150825 0.60566156 68.75 3.49454182e-01 7.50412003e-01 8.27790069e-01 1.13497715 0.14233158 69.00 3.20983899e-01 2.96127799e-01 4.36717686e-01 0.74514180 0.18390812 69.25 -1.54295655e-01 2.62082773e-01 3.04129132e-01 2.10288689 0.35263741 69.50 -2.20652536e-01 1.99035907e-01 2.97157928e-01 2.40765539 0.42660102 69.75 -3.30247026e-01 1.43387476e-01 3.60032035e-01 2.73197013 0.66335838 70.00 -3.94382425e-01 1.11950904e-01 4.09964025e-01 2.86500463 0.72098079 70.25 -4.59307161e-01 1.00789330e-01 4.70235641e-01 2.92557870 0.85371626 70.50 -4.49024789e-01 7.81971548e-02 4.55782905e-01 2.96917296 0.85168066 70.75 -4.56419414e-01 2.91910102e-02 4.57351940e-01 3.07772310 0.88645792 71.00 -4.53523838e-01 -4.79275783e-03 4.53549162e-01 -3.13102523 0.83265721 71.25 -5.09936463e-01 -6.43679770e-02 5.13982911e-01 -3.01602928 0.83467999 71.50 -4.98569924e-01 -1.24455154e-01 5.13868713e-01 -2.89696765 0.73540647 71.75 -5.08745906e-01 -2.08650324e-01 5.49870307e-01 -2.75238689 0.64347104 72.00 -6.11884233e-01 -2.06442304e-01 6.45771430e-01 -2.81619749 0.61252674 72.25 -7.14983725e-01 3.82737624e-02 7.16007408e-01 3.08811274 0.70463122 72.50 -6.65794675e-01 6.89381538e-02 6.69354180e-01 3.03841766 0.76169139 72.75 -6.46354862e-01 6.81702817e-02 6.49939839e-01 3.03651232 0.82811117 73.00 -5.88071624e-01 7.40740830e-02 5.92718487e-01 3.01629157 0.80379776 73.25 -5.38633743e-01 3.87698687e-02 5.40027233e-01 3.06973841 0.88452416 73.50 -5.81948713e-01 -2.15601828e-03 5.81952707e-01 -3.13788785 0.91457886 73.75 -5.95404793e-01 -1.11973468e-02 5.95510074e-01 -3.12278859 0.94672476 74.00 -5.98119876e-01 -3.46987952e-02 5.99125523e-01 -3.08364449 0.92436371 74.25 -6.01548689e-01 -1.47900732e-02 6.01730480e-01 -3.11701095 0.94833472 74.50 -6.02400798e-01 -2.40387092e-02 6.02880238e-01 -3.10170897 0.92842268 74.75 -6.06564850e-01 -2.42514327e-02 6.07049462e-01 -3.10163234 0.94023196 75.00 -6.07048944e-01 3.47971119e-03 6.07058917e-01 3.13586054 0.88245426 75.25 -5.86806874e-01 5.05286658e-02 5.88978313e-01 3.05569670 0.82278670 75.50 -6.11497152e-01 6.70138902e-02 6.15158214e-01 3.03243838 0.66455605 75.75 -6.08902592e-01 5.61900456e-02 6.11489729e-01 3.04957243 0.68333610 76.00 -5.61005538e-01 2.35318760e-01 6.08360199e-01 2.74442472 0.52074777 76.25 -5.40457848e-01 2.63623165e-01 6.01325085e-01 2.68777079 0.45425405 76.50 -4.85194387e-01 1.06271641e-01 4.96696340e-01 2.92596871 0.29571963 76.75 -5.24631118e-01 1.18943316e-01 5.37945464e-01 2.91864360 0.28039712 77.00 -1.01976987e+00 4.11546707e-01 1.09968235e+00 2.75801402 0.48804983 77.25 -1.16300353e+00 4.43703303e-01 1.24476898e+00 2.77712246 0.72433166 77.50 -1.45288173e+00 3.18273958e-01 1.48733440e+00 2.92593539 0.83407319 77.75 -1.67044624e+00 4.40782282e-01 1.72762255e+00 2.88360216 0.76117653 78.00 -2.50599168e+00 1.99995347e+00 3.20621399e+00 2.46803046 0.70371039 78.25 -2.15794741e+00 3.51467052e+00 4.12427519e+00 2.12143394 0.70828602 78.50 8.73515528e-01 4.06895691e+00 4.16166310e+00 1.35932796 0.68706383 78.75 1.85521229e+00 2.78754977e+00 3.34846925e+00 0.98357751 0.68289468 79.00 1.91118754e+00 1.05112713e+00 2.18117080e+00 0.50283276 0.77297280 79.25 1.58225493e+00 5.71248895e-01 1.68221757e+00 0.34647125 0.77158000 79.50 1.31303082e+00 3.78474509e-01 1.36648926e+00 0.28063777 0.87399926 79.75 1.20774207e+00 2.99296903e-01 1.24427471e+00 0.24292137 0.86039571 80.00 1.11017165e+00 6.89608050e-02 1.11231141e+00 0.06203754 0.87495714 80.25 1.02499044e+00 4.77633982e-02 1.02610270e+00 0.04656519 0.86919738 80.50 9.57779899e-01 1.05549815e-01 9.63578279e-01 0.10975968 0.82913751 80.75 1.00462087e+00 1.10801073e-01 1.01071261e+00 0.10984746 0.79434229 81.00 1.05611839e+00 -1.11381352e-01 1.06197545e+00 -0.10507453 0.89164755 81.25 9.52512414e-01 -1.67124189e-01 9.67062766e-01 -0.17368826 0.84100869 81.50 8.54011528e-01 -1.77054552e-01 8.72172004e-01 -0.20442500 0.87276442 81.75 7.89565201e-01 -1.98853685e-01 8.14221097e-01 -0.24672109 0.82644077 82.00 7.60232940e-01 -1.92696226e-01 7.84274161e-01 -0.24824185 0.81412410 82.25 7.40018841e-01 -2.07769842e-01 7.68632677e-01 -0.27371601 0.79382395 82.50 7.49192404e-01 -2.03895701e-01 7.76442345e-01 -0.26571838 0.84474632 82.75 7.40945248e-01 -2.24210211e-01 7.74125364e-01 -0.29384063 0.77816108 83.00 7.04473730e-01 -2.29015184e-01 7.40763923e-01 -0.31431050 0.80417573 83.25 6.98445784e-01 -2.16997335e-01 7.31378394e-01 -0.30123141 0.72659657 83.50 8.03635007e-01 -2.10894704e-01 8.30846437e-01 -0.25663908 0.75076572 83.75 7.69950655e-01 -2.60759108e-01 8.12907943e-01 -0.32654575 0.69054896 84.00 6.63617654e-01 -2.70890070e-01 7.16777386e-01 -0.38755703 0.67136345 84.25 6.27750968e-01 -2.82025127e-01 6.88192887e-01 -0.42224066 0.51315678 84.50 5.91377215e-01 -2.32379122e-01 6.35395206e-01 -0.37441031 0.50771939 84.75 6.30697572e-01 -2.13329029e-01 6.65799296e-01 -0.32616271 0.64102787 85.00 7.04991033e-01 -2.27529043e-01 7.40798098e-01 -0.31218675 0.80421234 85.25 7.45397828e-01 -2.76444562e-01 7.95009131e-01 -0.35514361 0.73696183 85.50 7.24677714e-01 -3.73521072e-01 8.15276505e-01 -0.47591575 0.75270417 85.75 7.01682188e-01 -4.28264162e-01 8.22051146e-01 -0.54798721 0.68866077 86.00 6.72589821e-01 -4.38220535e-01 8.02754200e-01 -0.57745848 0.68129828 86.25 6.79516390e-01 -5.02673126e-01 8.45235349e-01 -0.63690960 0.63069559 86.50 6.44469281e-01 -5.41120715e-01 8.41517844e-01 -0.69844738 0.64587684 86.75 5.97228565e-01 -6.08716863e-01 8.52770882e-01 -0.79492426 0.55307526 87.00 4.70533981e-01 -7.02144003e-01 8.45226850e-01 -0.98039375 0.58645377 87.25 2.96492392e-01 -5.02037733e-01 5.83051991e-01 -1.03733365 0.32005495 87.50 1.80212980e-01 -3.55506208e-01 3.98574187e-01 -1.10162856 0.20845643 87.75 2.43819685e-01 -7.18350385e-02 2.54181651e-01 -0.28651707 0.12850869 88.00 3.44776286e-01 -9.72495054e-02 3.58229192e-01 -0.27492304 0.26440978 88.25 3.95820140e-01 4.71406480e-02 3.98617391e-01 0.11853779 0.21045736 88.50 4.53011856e-01 1.59729737e-02 4.53293368e-01 0.03524490 0.19907733 88.75 4.04329634e-01 3.55675188e-03 4.04345277e-01 0.00879644 0.16087793 89.00 4.27043346e-01 -1.03179304e-01 4.39331297e-01 -0.23706975 0.13338262 89.25 4.66572408e-01 1.77162700e-01 4.99075579e-01 0.36289450 0.11646308 89.50 4.36076846e-01 1.47397382e-01 4.60314027e-01 0.32595167 0.09366073 89.75 3.52218337e-01 -1.00914267e-01 3.66389747e-01 -0.27903567 0.03972484 90.00 5.14830978e-01 -4.82277368e-01 7.05437734e-01 -0.75276174 0.11891837 90.25 5.29221046e-01 -6.29908644e-01 8.22714906e-01 -0.87204549 0.42964197 90.50 4.84137795e-01 -4.56318598e-01 6.65293970e-01 -0.75582626 0.47280882 90.75 6.02451049e-01 -2.42042068e-01 6.49254672e-01 -0.38202460 0.61088669 91.00 6.93261129e-01 -2.18708217e-01 7.26941729e-01 -0.30559507 0.53100197 91.25 8.87025895e-01 -2.76388079e-01 9.29088428e-01 -0.30205529 0.56638703 91.50 6.99232031e-01 -4.61183351e-01 8.37624926e-01 -0.58306433 0.62243518 91.75 5.88322319e-01 -4.69352757e-01 7.52605582e-01 -0.67338683 0.84664289 92.00 6.20869193e-01 -3.69962518e-01 7.22738417e-01 -0.53738337 0.85186680 92.25 7.80491633e-01 -2.40148191e-01 8.16601704e-01 -0.29849533 0.88929814 92.50 8.32945435e-01 -2.61872538e-01 8.73141067e-01 -0.30460887 0.81021708 92.75 7.83474599e-01 -3.77052836e-01 8.69483346e-01 -0.44854130 0.75962997 93.00 7.72859873e-01 -3.69295945e-01 8.56558158e-01 -0.44575516 0.63130145 93.25 6.14431583e-01 -3.91281506e-01 7.28441752e-01 -0.56705303 0.49247871 93.50 5.62429870e-01 -3.54935605e-01 6.65061382e-01 -0.56295615 0.47784328 93.75 5.85126151e-01 -3.00784124e-01 6.57908581e-01 -0.47482436 0.60979726 94.00 6.03393504e-01 -2.55117693e-01 6.55109730e-01 -0.40000986 0.53861918 94.25 6.14152885e-01 -2.60137154e-01 6.66974591e-01 -0.40065938 0.64998880 94.50 6.18005755e-01 -2.42705606e-01 6.63955664e-01 -0.37421815 0.52950349 94.75 6.30525832e-01 -2.93965132e-01 6.95685507e-01 -0.43626210 0.64579993 95.00 5.33852964e-01 -3.49531087e-01 6.38099498e-01 -0.57969518 0.46632349 95.25 4.76777949e-01 -3.83437938e-01 6.11834835e-01 -0.67731337 0.48453920 95.50 2.22786436e-01 -3.31319466e-01 3.99257291e-01 -0.97881997 0.17852088 95.75 5.09094394e-02 -2.68284815e-01 2.73072359e-01 -1.38326706 0.13012991 96.00 -7.33109194e-02 -8.99857133e-02 1.16068598e-01 -2.25443368 0.02514528 96.25 -8.94588944e-02 -3.47376624e-02 9.59666556e-02 -2.77120548 0.01755111 96.50 1.03362931e-02 3.56981631e-02 3.71644696e-02 1.28895689 0.00182690 96.75 -1.31689496e-01 1.90740397e-02 1.33063677e-01 2.99775195 0.02400623 97.00 -4.15288791e-01 7.42026481e-03 4.15355078e-01 3.12372683 0.21790499 97.25 -5.31340328e-01 9.16528594e-02 5.39187158e-01 2.97077984 0.41980363 97.50 -9.38550154e-01 2.31943120e-01 9.66785396e-01 2.89931777 0.73819404 97.75 -1.13707054e+00 3.41264513e-01 1.18717769e+00 2.85002020 0.83109781 98.00 -1.35832593e+00 6.81611463e-01 1.51975114e+00 2.67650402 0.82979900 98.25 -1.47329735e+00 9.71214481e-01 1.76461402e+00 2.55876913 0.86001075 98.50 -1.71707993e+00 1.25521548e+00 2.12695307e+00 2.51035144 0.90840009 98.75 -1.93098289e+00 1.39698817e+00 2.38333188e+00 2.51529486 0.92012515 99.00 -2.46660459e+00 1.85997679e+00 3.08928016e+00 2.49549590 0.88886977 99.25 -2.74410420e+00 2.32105618e+00 3.59407981e+00 2.43952224 0.83909139 99.50 -3.59430725e+00 3.61046278e+00 5.09455456e+00 2.35395216 0.80485810 99.75 -4.17377125e+00 5.35735984e+00 6.79129376e+00 2.23264565 0.82398637 100.00 -4.22307529e+00 9.68083977e+00 1.05618665e+01 1.98214053 0.86440162 100.25 -2.09914111e+00 1.17478255e+01 1.19338928e+01 1.74761367 0.79981379 100.50 6.31768717e+00 1.20613049e+01 1.36157353e+01 1.08829209 0.84049355 100.75 8.76282881e+00 9.63692163e+00 1.30252611e+01 0.83286816 0.85792009 101.00 9.74094875e+00 5.98652768e+00 1.14334857e+01 0.55106635 0.89268945 101.25 9.01939399e+00 3.97370004e+00 9.85595049e+00 0.41498670 0.89489547 101.50 8.51900064e+00 2.69668813e+00 8.93563085e+00 0.30657012 0.95042298 101.75 7.97644895e+00 2.02683415e+00 8.22993283e+00 0.24883592 0.94841556 102.00 7.39677070e+00 1.08515207e+00 7.47594622e+00 0.14566707 0.95645263 102.25 7.09093732e+00 5.82236060e-01 7.11480083e+00 0.08192610 0.96162703 102.50 6.67097001e+00 7.03967863e-02 6.67134144e+00 0.01055231 0.97489781 102.75 5.97299903e+00 -1.61946793e-01 5.97519407e+00 -0.02710650 0.96874810 103.00 5.59759884e+00 -1.71599854e-01 5.60022850e+00 -0.03064638 0.99020166 103.25 5.38932353e+00 -1.19339422e-01 5.39064468e+00 -0.02214006 0.98752345 103.50 5.07313695e+00 9.12879060e-02 5.07395821e+00 0.01799243 0.98984620 103.75 4.87397178e+00 1.21548105e-01 4.87548714e+00 0.02493304 0.99207798 104.00 4.79718926e+00 1.95630696e-01 4.80117654e+00 0.04075769 0.99463255 104.25 4.81281861e+00 2.82583421e-01 4.82110737e+00 0.05864741 0.98963662 104.50 4.88241601e+00 3.93922688e-01 4.89828145e+00 0.08050753 0.99124116 104.75 5.07331328e+00 3.63138697e-01 5.08629309e+00 0.07145634 0.98806237 105.00 5.17506833e+00 2.79176707e-01 5.18259316e+00 0.05389424 0.98871205 105.25 5.13705746e+00 2.54912061e-01 5.14337822e+00 0.04958152 0.98642852 105.50 5.15857241e+00 2.20119424e-01 5.16326659e+00 0.04264474 0.99214606 105.75 5.25603314e+00 1.58995923e-01 5.25843742e+00 0.03024095 0.99123666 106.00 5.36022141e+00 1.07956970e-01 5.36130845e+00 0.02013767 0.99223495 106.25 5.47863550e+00 3.19865250e-02 5.47872888e+00 0.00583834 0.98907432 106.50 5.63423326e+00 -1.08273373e-01 5.63527351e+00 -0.01921469 0.99118080 106.75 5.71927607e+00 -2.78218877e-01 5.72603917e+00 -0.04860750 0.99076381 107.00 5.67524348e+00 -3.80858407e-01 5.68800859e+00 -0.06700826 0.98806517 107.25 5.50027367e+00 -8.44766600e-01 5.56476783e+00 -0.15239546 0.97803361 107.50 5.53033121e+00 -9.99933333e-01 5.62000266e+00 -0.17887638 0.98509869 107.75 5.43154895e+00 -1.28119720e+00 5.58060841e+00 -0.23164634 0.97149945 108.00 5.34629299e+00 -1.56237452e+00 5.56990690e+00 -0.28431791 0.97170231 108.25 4.85450982e+00 -2.17139404e+00 5.31800881e+00 -0.42060150 0.95933438 108.50 4.32223574e+00 -2.31845559e+00 4.90478931e+00 -0.49234333 0.96171936 108.75 3.75757126e+00 -2.06824497e+00 4.28916997e+00 -0.50316614 0.95230233 109.00 3.51740156e+00 -1.81426577e+00 3.95773597e+00 -0.47620533 0.94392625 109.25 3.10115030e+00 -1.64689986e+00 3.51132630e+00 -0.48818651 0.94929844 109.50 2.87521061e+00 -1.48646893e+00 3.23673074e+00 -0.47715083 0.94777477 109.75 2.76401325e+00 -9.41383455e-01 2.91992672e+00 -0.32826344 0.92638108 110.00 2.81788430e+00 -6.09832790e-01 2.88311775e+00 -0.21312837 0.86896357 110.25 1.96069071e+00 -9.14925065e-01 2.16365338e+00 -0.43660038 0.72477832 110.50 1.74495506e+00 -7.20022993e-01 1.88767085e+00 -0.39134774 0.82762445 110.75 1.90029216e+00 -1.97270181e-01 1.91050407e+00 -0.10343993 0.94060829 111.00 1.94328182e+00 -4.43228686e-02 1.94378722e+00 -0.02280430 0.94914985 111.25 1.93471746e+00 9.45136953e-02 1.93702465e+00 0.04881261 0.94853089 111.50 1.86255324e+00 2.45505896e-01 1.87866381e+00 0.13105596 0.89721173 111.75 1.82128765e+00 6.78898759e-01 1.94370579e+00 0.35680326 0.88344568 112.00 1.73256601e+00 8.56733451e-01 1.93281587e+00 0.45922846 0.87584929 112.25 1.55726859e+00 9.33317583e-01 1.81553496e+00 0.53992661 0.86631511 112.50 1.38095820e+00 1.21563317e+00 1.83978519e+00 0.72181397 0.81371749 112.75 9.84859164e-01 1.48536910e+00 1.78220900e+00 0.98530868 0.82937001 113.00 5.43287063e-01 2.11516262e+00 2.18382091e+00 1.31937772 0.71885947 113.25 6.68746211e-01 3.66768336e+00 3.72815272e+00 1.39044281 0.86514729 113.50 1.45610912e+00 4.65618297e+00 4.87855446e+00 1.26770565 0.87502048 113.75 2.72554362e+00 5.55998969e+00 6.19209766e+00 1.11501409 0.91052223 114.00 4.01041150e+00 4.36298258e+00 5.92613005e+00 0.82747942 0.86583077 114.25 4.45843011e+00 3.10000370e+00 5.43025064e+00 0.60757329 0.95562092 114.50 4.30953534e+00 2.80114672e+00 5.13989473e+00 0.57636686 0.94931872 114.75 3.90556537e+00 2.62928459e+00 4.70813958e+00 0.59252227 0.94197547 115.00 3.59540500e+00 2.44708403e+00 4.34915593e+00 0.59759660 0.91984385 115.25 3.44541341e+00 2.39804856e+00 4.19779829e+00 0.60804433 0.94227748 115.50 3.05216194e+00 2.25799885e+00 3.79661050e+00 0.63694308 0.92692969 115.75 2.53824900e+00 2.31862174e+00 3.43783576e+00 0.74020904 0.90221626 116.00 2.04553677e+00 2.64819192e+00 3.34621295e+00 0.91309533 0.86636230 116.25 1.98412769e+00 3.09691762e+00 3.67799694e+00 1.00100213 0.90028701 116.50 2.04227025e+00 3.48136061e+00 4.03617882e+00 1.04026579 0.89311745 116.75 2.05910688e+00 3.70293510e+00 4.23693870e+00 1.06330155 0.88138688 117.00 2.24297134e+00 2.79055453e+00 3.58023952e+00 0.89375923 0.83263019 117.25 2.01406089e+00 2.56959242e+00 3.26485015e+00 0.90600833 0.90637246 117.50 1.12451727e+00 2.85529134e+00 3.06875019e+00 1.19561478 0.89737657 117.75 5.86637540e-01 3.16338028e+00 3.21731541e+00 1.38743295 0.94292111 118.00 9.86115473e-02 3.49928634e+00 3.50067552e+00 1.54262331 0.84898969 118.25 -4.40699971e-01 4.10075785e+00 4.12437043e+00 1.67785338 0.83799434 118.50 -5.03706171e-01 4.38194655e+00 4.41080213e+00 1.68524432 0.70763499 118.75 -3.89838496e-02 4.76036747e+00 4.76052710e+00 1.57898540 0.57257692 119.00 9.13370459e-01 4.69867256e+00 4.78662401e+00 1.37880169 0.46679854 119.25 1.35870538e+00 4.25279448e+00 4.46456506e+00 1.26156033 0.42057886 119.50 3.99378109e+00 3.95751711e+00 5.62247535e+00 0.78083743 0.57283992 119.75 4.37113008e+00 3.05965757e+00 5.33556770e+00 0.61070547 0.68120250 120.00 3.37051630e+00 2.68896697e+00 4.31171932e+00 0.67339243 0.77814104 120.25 3.14797737e+00 3.01035619e+00 4.35568662e+00 0.76305474 0.83757596 120.50 2.69190288e+00 2.88809970e+00 3.94809587e+00 0.82054439 0.87764876 120.75 2.36039237e+00 2.80622258e+00 3.66692478e+00 0.87147552 0.87732989 121.00 1.70944068e+00 2.94264724e+00 3.40313975e+00 1.04452489 0.90327849 121.25 1.47467568e+00 2.98155507e+00 3.32631012e+00 1.11147844 0.88799494 121.50 9.22920943e-01 3.42514333e+00 3.54730741e+00 1.30759282 0.89171783 121.75 1.14316551e+00 3.84448026e+00 4.01084229e+00 1.28177027 0.87178175 122.00 1.95894395e+00 4.09449825e+00 4.53898417e+00 1.12455053 0.89934962 122.25 2.32993105e+00 3.65387215e+00 4.33351594e+00 1.00314437 0.90665375 122.50 2.31276592e+00 3.39826093e+00 4.11060379e+00 0.97322769 0.93231441 122.75 2.41189329e+00 3.27679870e+00 4.06873924e+00 0.93628205 0.87143033 123.00 3.67364990e+00 2.79928166e+00 4.61862332e+00 0.65113016 0.78710657 123.25 4.03684112e+00 7.95906461e-01 4.11455384e+00 0.19466399 0.66605907 123.50 2.32823559e+00 -1.25827704e+00 2.64649619e+00 -0.49547566 0.56246299 123.75 7.77006512e-01 -3.71554763e-01 8.61273512e-01 -0.44604580 0.15514066 124.00 2.89606706e-01 3.67454238e-01 4.67861797e-01 0.90332682 0.25546860 124.25 2.38715958e-01 4.15686131e-01 4.79354012e-01 1.04951104 0.33480611 124.50 1.89576353e-01 5.38235062e-01 5.70645403e-01 1.23214647 0.49601523 124.75 1.38421963e-01 5.92664265e-01 6.08614468e-01 1.34135057 0.54574192 125.00 2.39119507e-02 5.19222887e-01 5.19773208e-01 1.52477550 0.55053318 125.25 -8.55398742e-02 4.36985086e-01 4.45278604e-01 1.76410212 0.43747970 125.50 -2.07859930e-01 4.10437152e-01 4.60070001e-01 2.03957904 0.48880140 125.75 -2.94792773e-01 3.17187913e-01 4.33025347e-01 2.31961629 0.42527996 126.00 -3.25235185e-01 3.03096787e-01 4.44573490e-01 2.39141352 0.59601789 126.25 -4.74689720e-01 2.39235952e-01 5.31567654e-01 2.67476305 0.62118759 126.50 -5.68152353e-01 1.91299525e-01 5.99493623e-01 2.81681101 0.79068421 126.75 -7.51067867e-01 1.59773323e-01 7.67873984e-01 2.93198892 0.79077272 127.00 -9.00574605e-01 2.23059332e-01 9.27787737e-01 2.89879346 0.86578601 127.25 -6.74659659e-01 4.08171175e-01 7.88523534e-01 2.59750253 0.70548243 127.50 -4.96831064e-01 3.98159695e-01 6.36688502e-01 2.46599952 0.68956827 127.75 -3.99349680e-01 2.49848448e-01 4.71067314e-01 2.58253448 0.59454952 128.00 -3.56914212e-01 1.95344735e-01 4.06875067e-01 2.64081270 0.57716986 128.25 -2.79124916e-01 4.74601389e-02 2.83131036e-01 2.97317150 0.37082025 128.50 -1.95368581e-01 -4.33314275e-03 1.95416628e-01 -3.11941697 0.23392035 128.75 -1.95449363e-02 -3.01382730e-01 3.02015818e-01 -1.63555653 0.35755555 129.00 1.03202913e-02 -5.40303639e-01 5.40402194e-01 -1.55169774 0.61979679 129.25 -2.05486963e-01 -8.88416012e-01 9.11870552e-01 -1.79809514 0.87383541 129.50 -2.66319577e-01 -1.01184528e+00 1.04630636e+00 -1.82816117 0.91744105 129.75 -4.57302385e-01 -1.37263311e+00 1.44680583e+00 -1.89238821 0.93945331 130.00 -6.08558772e-01 -1.53265783e+00 1.64905542e+00 -1.94876659 0.95597984 130.25 -1.05678602e+00 -1.62770926e+00 1.94067878e+00 -2.14664230 0.95935892 130.50 -1.42884438e+00 -1.50166638e+00 2.07282372e+00 -2.33135001 0.94572893 130.75 -1.94682885e+00 -1.13476173e+00 2.25340337e+00 -2.61385876 0.95877765 131.00 -1.85454413e+00 -8.36688546e-01 2.03454704e+00 -2.71777789 0.92371433 131.25 -1.50622496e+00 -3.21944905e-01 1.54024743e+00 -2.93101835 0.94053611 131.50 -1.30651905e+00 -3.76184159e-01 1.35959794e+00 -2.86124703 0.91518134 131.75 -1.11684376e+00 -5.60498231e-01 1.24959923e+00 -2.67645885 0.96108842 132.00 -1.08946060e+00 -5.88023230e-01 1.23802089e+00 -2.64666230 0.95877264 132.25 -1.08656346e+00 -5.50371039e-01 1.21800182e+00 -2.67273906 0.94970449 132.50 -1.05764851e+00 -4.64251985e-01 1.15505423e+00 -2.72796805 0.92261363 132.75 -8.59307505e-01 -3.67064577e-01 9.34422705e-01 -2.73789115 0.87619985 133.00 -7.59161240e-01 -4.25571889e-01 8.70308693e-01 -2.63066162 0.89247045 133.25 -6.43654586e-01 -4.38265437e-01 7.78696231e-01 -2.54379973 0.92446926 133.50 -5.52640772e-01 -4.64662451e-01 7.22027020e-01 -2.44246176 0.87160395 133.75 -4.06709816e-01 -4.41376048e-01 6.00188046e-01 -2.31534138 0.84872961 134.00 -2.92204272e-01 -4.18813435e-01 5.10674094e-01 -2.17997401 0.65552642 134.25 9.97504670e-03 -5.36174260e-01 5.36267040e-01 -1.55219436 0.71978741 134.50 1.38236597e-01 -5.47053135e-01 5.64248606e-01 -1.32328452 0.83182925 134.75 2.56219366e-01 -5.16825037e-01 5.76850485e-01 -1.11054929 0.89691161 135.00 4.72365618e-01 -4.96434351e-01 6.85256406e-01 -0.81023692 0.86783280 135.25 7.87510870e-01 -5.29259317e-01 9.48835494e-01 -0.59173133 0.91412383 135.50 1.14072182e+00 -5.95535305e-01 1.28682111e+00 -0.48114640 0.89905989 135.75 1.46467899e+00 -9.43982444e-01 1.74252329e+00 -0.57249754 0.94104714 136.00 1.71398342e+00 -1.19649897e+00 2.09029877e+00 -0.60943677 0.93151048 136.25 1.98260232e+00 -1.50233581e+00 2.48751379e+00 -0.64844874 0.95280268 136.50 2.23135699e+00 -1.54739848e+00 2.71539980e+00 -0.60633581 0.94296710 136.75 2.65391185e+00 -1.65493007e+00 3.12762556e+00 -0.55757855 0.94250044 137.00 3.49320486e+00 -1.93286991e+00 3.99230088e+00 -0.50539073 0.92408223 137.25 4.32825927e+00 -2.27025007e+00 4.88752123e+00 -0.48306910 0.92809081 137.50 5.23977171e+00 -3.00931016e+00 6.04244613e+00 -0.52132373 0.84837510 137.75 5.79097542e+00 -4.56916929e+00 7.37649675e+00 -0.66800709 0.81410201 138.00 4.40014718e+00 -6.33534965e+00 7.71349145e+00 -0.96374490 0.63548121 138.25 2.23104602e+00 -7.14468748e+00 7.48492656e+00 -1.26812427 0.49460592 138.50 -2.43122316e+00 -6.46526171e+00 6.90727551e+00 -1.93048201 0.61621608 138.75 -3.13342919e+00 -5.97431517e+00 6.74617078e+00 -2.05383827 0.75784448 139.00 -2.34498430e+00 -5.89308912e+00 6.34251139e+00 -1.94950923 0.80731855 139.25 -2.03811282e+00 -5.67698635e+00 6.03175579e+00 -1.91547802 0.84998786 139.50 -1.52144740e+00 -4.77658230e+00 5.01303707e+00 -1.87915815 0.82933756 139.75 -1.21572668e+00 -4.91215756e+00 5.06036394e+00 -1.81341447 0.86456477 140.00 1.14178385e-01 -5.54843279e+00 5.54960748e+00 -1.55022074 0.89546106 140.25 1.01613734e+00 -5.91789102e+00 6.00449575e+00 -1.40074857 0.91338749 140.50 2.44922898e+00 -7.23072439e+00 7.63427127e+00 -1.24420092 0.91317245 140.75 2.71950160e+00 -8.41144351e+00 8.84013975e+00 -1.25809397 0.87601352 141.00 2.25973722e+00 -1.38759423e+01 1.40587406e+01 -1.40936064 0.85028598 141.25 6.54596267e-01 -1.63964005e+01 1.64094620e+01 -1.53089435 0.86047812 141.50 -6.64005258e+00 -1.57993666e+01 1.71379778e+01 -1.96865665 0.89174611 141.75 -8.47188612e+00 -1.49062458e+01 1.71455247e+01 -2.08761460 0.90852539 142.00 -9.38595092e+00 -1.19725382e+01 1.52130781e+01 -2.23567789 0.88045643 142.25 -9.48489989e+00 -1.05704413e+01 1.42020264e+01 -2.30211996 0.83074613 142.50 -1.14448839e+01 -9.41746192e+00 1.48214020e+01 -2.45307120 0.81921175 142.75 -1.16258343e+01 -8.84395398e+00 1.46073798e+01 -2.49126873 0.85281899 143.00 -1.14557592e+01 -7.93536695e+00 1.39357263e+01 -2.53578505 0.88352311 143.25 -1.11602850e+01 -7.25405159e+00 1.33106433e+01 -2.56522585 0.84501951 143.50 -1.27945797e+01 -7.22788753e+00 1.46950205e+01 -2.62736832 0.87201450 143.75 -1.29237368e+01 -5.65858663e+00 1.41082449e+01 -2.72889312 0.81886132 144.00 -1.31213820e+01 -5.26869951e+00 1.41396556e+01 -2.75976335 0.84875398 144.25 -1.35033083e+01 -4.95299615e+00 1.43830284e+01 -2.79003146 0.80461415 144.50 -1.49560898e+01 -4.02939824e+00 1.54893729e+01 -2.87842594 0.80131325 144.75 -1.52658792e+01 -4.20780251e+00 1.58351719e+01 -2.87263668 0.76991518 145.00 -1.79599198e+01 -3.98240105e+00 1.83961474e+01 -2.92338496 0.78843481 145.25 -1.84964280e+01 -1.74483747e+00 1.85785442e+01 -3.04753724 0.72417188 145.50 -2.20717669e+01 2.58502141e+00 2.22226287e+01 3.02500487 0.81470079 145.75 -2.21734644e+01 5.74994327e+00 2.29068630e+01 2.88786500 0.74666266 146.00 -2.46613408e+01 1.04956743e+01 2.68018826e+01 2.73922051 0.67113642 146.25 -2.18507629e+01 1.68239066e+01 2.75771586e+01 2.48544786 0.61663180 146.50 -1.71393715e+01 2.48403727e+01 3.01794992e+01 2.17476606 0.65567769 146.75 -5.06345985e+00 2.66331248e+01 2.71101819e+01 1.75867301 0.61169925 147.00 5.37336144e+00 2.67120404e+01 2.72471304e+01 1.37228680 0.71511149 147.25 9.73550185e+00 1.85392090e+01 2.09399682e+01 1.08724712 0.66086981 147.50 1.21707572e+01 1.49876362e+01 1.93069047e+01 0.88874899 0.69374863 147.75 1.19432303e+01 6.33025286e+00 1.35171318e+01 0.48738086 0.56485232 148.00 9.78515629e+00 2.92853240e+00 1.02139897e+01 0.29079900 0.49958636 148.25 5.83489947e+00 4.13234546e-01 5.84951405e+00 0.07070314 0.40162543 148.50 5.16104997e+00 5.09650880e-01 5.18615279e+00 0.09843034 0.42996074 148.75 2.73328442e+00 1.20449061e-01 2.73593708e+00 0.04403903 0.21453297 149.00 2.50949869e+00 -3.58603012e-01 2.53499109e+00 -0.14193736 0.22165634 149.25 2.06114752e+00 -8.36605966e-02 2.06284468e+00 -0.04056706 0.20365818 149.50 1.29112716e+00 2.75370388e-01 1.32016598e+00 0.21013068 0.10176021 149.75 1.91216845e-01 5.11725808e-01 5.46284893e-01 1.21319174 0.01928155 150.00 4.90301199e-01 9.29718462e-01 1.05108120e+00 1.08549695 0.06902001 150.25 -1.74647667e-01 8.64091324e-01 8.81564305e-01 1.77022677 0.06674369 150.50 -1.05815911e-01 1.38372359e+00 1.38776367e+00 1.64711964 0.16910023 150.75 6.24544611e-01 1.96537377e-01 6.54738811e-01 0.30487796 0.03875255 151.00 5.08420997e-01 -8.44369975e-02 5.15384824e-01 -0.16457482 0.02646835 151.25 -1.37683312e-01 3.30022117e-01 3.57590956e-01 1.96603686 0.01817638 151.50 -3.95254492e-01 5.19575265e-01 6.52828132e-01 2.22112690 0.07661162 151.75 -6.66426735e-01 5.17932842e-01 8.44025486e-01 2.48092270 0.13405238 152.00 -3.13931002e-01 2.43162070e-01 3.97089998e-01 2.48255022 0.03677953 152.25 6.35009663e-01 3.22455463e-01 7.12190142e-01 0.46986506 0.11344014 152.50 4.98557591e-01 1.19634689e-02 4.98701109e-01 0.02399156 0.04462436 152.75 -2.92743976e-01 -5.43963326e-01 6.17733871e-01 -2.06451057 0.04393481 153.00 -2.94428998e-01 -6.58887254e-01 7.21679186e-01 -1.99103424 0.05118656 153.25 9.95314574e-02 3.65839333e-01 3.79137084e-01 1.30516238 0.01409515 153.50 -3.82422373e-02 6.69488504e-01 6.70579843e-01 1.62785590 0.05646152 153.75 -5.14151656e-02 1.54847282e+00 1.54932617e+00 1.60398792 0.20716312 154.00 1.59330136e-01 1.76131124e+00 1.76850315e+00 1.48058079 0.24282751 154.25 5.13160496e-01 1.55387299e+00 1.63641528e+00 1.25182685 0.23531959 154.50 1.18156601e+00 1.45019012e+00 1.87060141e+00 0.88711618 0.31471603 154.75 1.96669506e+00 1.43314211e+00 2.43347196e+00 0.62973296 0.49469112 155.00 1.94985851e+00 8.29737980e-01 2.11905954e+00 0.40232585 0.36761507 155.25 1.91432259e+00 1.37083268e-01 1.91922453e+00 0.07148726 0.34674928 155.50 1.68328638e+00 -2.14792401e-01 1.69693513e+00 -0.12691713 0.29086117 155.75 1.84013692e+00 -5.54402102e-01 1.92183911e+00 -0.29263351 0.35890126 156.00 1.59338661e+00 -7.00347640e-01 1.74050789e+00 -0.41411642 0.34648579 156.25 1.55640043e+00 -1.06245254e+00 1.88445953e+00 -0.59897590 0.41939951 156.50 1.35121711e+00 -1.83134781e+00 2.27587839e+00 -0.93513183 0.38335403 156.75 1.32047933e+00 -2.61557041e+00 2.92999560e+00 -1.10327363 0.58111740 157.00 1.02790174e+00 -2.49904143e+00 2.70218246e+00 -1.18057094 0.51840411 157.25 6.64898358e-01 -3.07017512e+00 3.14134765e+00 -1.35752296 0.59226046 157.50 -7.21894672e-01 -3.61902144e+00 3.69031816e+00 -1.76768447 0.52823129 157.75 -1.33071916e+00 -4.00234905e+00 4.21777328e+00 -1.89178277 0.55096431 158.00 -3.59513440e+00 -4.09434021e+00 5.44872583e+00 -2.29136480 0.51463074 158.25 -6.66045407e+00 -3.31079077e+00 7.43794218e+00 -2.68028230 0.59013864 158.50 -6.97062488e+00 2.03915122e+00 7.26276455e+00 2.85699855 0.50506713 158.75 -5.68133433e+00 5.17668718e+00 7.68606856e+00 2.40263797 0.54264129 159.00 -1.85575757e+00 4.89380762e+00 5.23385032e+00 1.93324869 0.41426829 159.25 -1.29639128e-02 4.03197285e+00 4.03199369e+00 1.57401159 0.37349179 159.50 5.18487070e-01 3.16568888e+00 3.20786766e+00 1.40845436 0.39113160 159.75 7.50372850e-02 3.22170362e+00 3.22257736e+00 1.54750936 0.47756710 160.00 -2.78321237e-01 3.89311025e+00 3.90304626e+00 1.64216562 0.56765116 160.25 -3.05703463e-01 4.65791608e+00 4.66793710e+00 1.63633329 0.61853577 160.50 -4.04368717e-01 4.92667838e+00 4.94324529e+00 1.65269011 0.55082845 160.75 -8.83172315e-02 5.81079669e+00 5.81146781e+00 1.58599397 0.56975455 161.00 -1.25796445e+00 5.96967766e+00 6.10078077e+00 1.77848346 0.56118834 161.25 -1.95331599e+00 5.77940894e+00 6.10057465e+00 1.89672169 0.52184427 161.50 -2.74793136e+00 6.90028659e+00 7.42731996e+00 1.94977969 0.38886569 161.75 -3.97118694e+00 6.87031617e+00 7.93546281e+00 2.09489800 0.37924109 162.00 -6.08681877e+00 6.76548732e+00 9.10061434e+00 2.30343829 0.37126373 162.25 -5.38283968e+00 5.62000519e+00 7.78199341e+00 2.33464290 0.27504209 162.50 -4.48502549e+00 2.06651808e+00 4.93821330e+00 2.70982724 0.06303671 162.75 -3.70413627e+00 2.80096489e-01 3.71471123e+00 3.06611907 0.03638719 163.00 -9.30562099e-01 -2.22585476e-01 9.56812476e-01 -2.90680930 0.00115905 163.25 -7.78678159e-01 -7.10538953e-01 1.05413722e+00 -2.40191765 0.00150231 163.50 -2.83243543e+00 2.13178996e+00 3.54502735e+00 2.49640729 0.02002117 163.75 -1.69967952e+00 2.20872299e+00 2.78699976e+00 2.22668018 0.01836234 164.00 -5.05036873e-01 6.22691173e+00 6.24735880e+00 1.65172470 0.11313619 164.25 -1.69435525e+00 4.23930433e+00 4.56536318e+00 1.95102480 0.08249551 164.50 -2.24569197e+00 6.02326712e+00 6.42828743e+00 1.92766861 0.21640383 164.75 -2.54087736e+00 4.73507791e+00 5.37373432e+00 2.06329912 0.21324066 165.00 -6.05048096e+00 5.29093311e+00 8.03755516e+00 2.42306581 0.44251902 165.25 -6.00466758e+00 4.61008673e+00 7.57026633e+00 2.48682766 0.47471721 165.50 -7.56055712e+00 4.78344124e+00 8.94669403e+00 2.57748705 0.68134999 165.75 -7.34421866e+00 3.09992385e+00 7.97164197e+00 2.74218908 0.60625837 166.00 -6.52592373e+00 2.91926920e+00 7.14911276e+00 2.72095778 0.62552752 166.25 -6.68939278e+00 2.07390848e+00 7.00350427e+00 2.84096015 0.66159746 166.50 -7.37587323e+00 1.67583922e+00 7.56385768e+00 2.91817995 0.81224866 166.75 -7.32149579e+00 1.11634892e+00 7.40611474e+00 2.99028254 0.78761247 167.00 -7.63293152e+00 5.32796730e-01 7.65150416e+00 3.07190332 0.79493645 167.25 -7.36657792e+00 -1.66887585e-01 7.36846807e+00 -3.11894183 0.67923883 167.50 -7.82794193e+00 -9.41402633e-01 7.88434613e+00 -3.02190562 0.60312438 167.75 -8.99801439e+00 -8.78912589e-01 9.04083792e+00 -3.04422304 0.50410888 168.00 -1.20368251e+01 -6.85404583e-01 1.20563236e+01 -3.08471177 0.55560998 168.25 -1.51455523e+01 1.20828448e+00 1.51936732e+01 3.06198309 0.73544362 168.50 -1.69144603e+01 2.60028078e+00 1.71131653e+01 2.98905559 0.85323238 168.75 -1.75209751e+01 3.88824155e+00 1.79472279e+01 2.92321245 0.85255335 169.00 -1.89752289e+01 3.65220377e+00 1.93235065e+01 2.95144574 0.87838171 169.25 -2.11370127e+01 8.41948328e+00 2.27521648e+01 2.76252770 0.79278194 169.50 -2.38745673e+01 1.44740256e+01 2.79193908e+01 2.59658811 0.79405516 169.75 -1.68401729e+01 2.61936932e+01 3.11400223e+01 2.14217082 0.77233490 170.00 -9.57638299e+00 3.15136750e+01 3.29365879e+01 1.86580916 0.81922081 170.25 5.64839363e+00 2.84048412e+01 2.89609971e+01 1.37450370 0.81339431 170.50 1.15627470e+01 2.23042051e+01 2.51231902e+01 1.09252857 0.80672740 170.75 1.12415291e+01 8.44264010e+00 1.40588103e+01 0.64415512 0.65333249 171.00 1.15024985e+01 4.49264519e+00 1.23487381e+01 0.37235935 0.78478247 171.25 7.26916850e+00 1.96770302e+00 7.53078123e+00 0.26435635 0.54372092 171.50 4.46233579e+00 -2.98865536e-02 4.46243587e+00 -0.00669741 0.34389748 171.75 9.97162293e-01 -3.66251093e-01 1.06229586e+00 -0.35199711 0.02956706 172.00 -1.06190988e+00 4.33022304e-01 1.14680465e+00 2.75440010 0.02861968 172.25 -1.52188604e+00 2.20003783e+00 2.67512683e+00 2.17596693 0.14019185 172.50 -3.68685534e-01 3.69461030e+00 3.71296031e+00 1.67025715 0.21823266 172.75 5.26317811e-01 5.07514847e+00 5.10236635e+00 1.46746081 0.58836177 173.00 4.69171662e-01 4.19408146e+00 4.22024186e+00 1.45939430 0.54922668 173.25 -4.36787226e-01 2.87423645e+00 2.90723550e+00 1.72160880 0.53848734 173.50 -8.01266291e-01 2.86092023e+00 2.97100862e+00 1.84387265 0.62767945 173.75 -7.94726052e-01 2.87720962e+00 2.98494970e+00 1.84029099 0.58829589 174.00 -9.24247268e-01 2.78381085e+00 2.93322960e+00 1.89135354 0.43585605 174.25 3.62234068e-01 5.10495019e+00 5.11778565e+00 1.49995764 0.64347959 174.50 6.40499561e-01 5.51743747e+00 5.55448971e+00 1.45522719 0.80972743 174.75 4.31492523e-02 5.26327845e+00 5.26345532e+00 1.56259834 0.82440366 175.00 1.26994286e-01 4.95364265e+00 4.95527023e+00 1.54516540 0.83821001 175.25 3.92368896e-01 4.71398107e+00 4.73028232e+00 1.48775261 0.83743457 175.50 3.00292560e-01 4.86089531e+00 4.87016210e+00 1.50909752 0.82140511 175.75 2.50921653e-01 4.80919901e+00 4.81574052e+00 1.51866824 0.80276732 176.00 9.04100489e-01 4.98861550e+00 5.06987991e+00 1.39150959 0.78675330 176.25 1.78978844e+00 4.56706752e+00 4.90524703e+00 1.19730075 0.77645487 176.50 2.23966842e+00 3.89975209e+00 4.49713031e+00 1.04948041 0.78220516 176.75 3.10535674e+00 3.13557354e+00 4.41305584e+00 0.79023984 0.82734361 177.00 3.08431961e+00 2.76621433e+00 4.14306278e+00 0.73107964 0.81370621 177.25 3.13537231e+00 2.42453108e+00 3.96344680e+00 0.65823667 0.84498977 177.50 3.14871961e+00 1.99655812e+00 3.72836151e+00 0.56510620 0.78383364 177.75 3.44132622e+00 1.59055899e+00 3.79112174e+00 0.43294774 0.78750551 178.00 3.43111612e+00 1.14363044e+00 3.61669025e+00 0.32173090 0.70101359 178.25 3.33102965e+00 8.73418235e-01 3.44363441e+00 0.25643390 0.64599196 178.50 2.89162902e+00 6.61162667e-01 2.96625260e+00 0.22478311 0.49564487 178.75 3.13671735e+00 1.29931320e-01 3.13940725e+00 0.04139904 0.43671808 179.00 4.08779499e+00 -2.17350236e+00 4.62970630e+00 -0.48868899 0.58440165 179.25 3.01508505e+00 -3.82361496e+00 4.86937051e+00 -0.90308047 0.65988007 179.50 2.74084619e-01 -4.18686002e+00 4.19582164e+00 -1.50542655 0.57420995 179.75 -1.08758296e+00 -3.58399521e+00 3.74537826e+00 -1.86542026 0.67043044 180.00 -1.60093788e+00 -2.23365879e+00 2.74813276e+00 -2.19266471 0.64541769 180.25 -2.20417855e+00 -1.62536824e+00 2.73865386e+00 -2.50620238 0.63862631 180.50 -2.26690457e+00 -4.71761982e-01 2.31547311e+00 -2.93641281 0.55470876 180.75 -2.23580404e+00 -4.47866120e-02 2.23625257e+00 -3.12156379 0.70450529 181.00 -1.94174801e+00 4.07197881e-01 1.98398474e+00 2.93488123 0.67643384 181.25 -1.72048173e+00 6.46417008e-01 1.83790977e+00 2.78219212 0.65303034 181.50 -1.56264602e+00 8.91268263e-01 1.79895016e+00 2.62325367 0.63883092 181.75 -1.42781637e+00 9.98595363e-01 1.74236974e+00 2.53127862 0.66083287 182.00 -1.13118567e+00 1.37656755e+00 1.78171806e+00 2.25865570 0.75753408 182.25 -1.03859970e+00 1.51167826e+00 1.83408302e+00 2.17277856 0.79725132 182.50 -8.60861670e-01 1.35223643e+00 1.60300536e+00 2.13770847 0.68459820 182.75 -7.64850335e-01 1.35170471e+00 1.55309422e+00 2.08572035 0.66816854 183.00 -3.77585843e-01 1.30334041e+00 1.35693305e+00 1.85278275 0.62323495 183.25 -1.82117587e-01 1.28297663e+00 1.29583790e+00 1.71180355 0.61831965 183.50 2.77461625e-02 1.16231400e+00 1.16264512e+00 1.54692937 0.62572781 183.75 8.87157278e-02 1.10638412e+00 1.10993527e+00 1.49078224 0.56952051 184.00 1.61705866e-01 1.04559711e+00 1.05802746e+00 1.41735784 0.46357338 184.25 1.48599891e-01 9.09628881e-01 9.21686839e-01 1.40886354 0.36965103 184.50 1.81155035e-01 9.75272413e-01 9.91954347e-01 1.38714128 0.48517650 184.75 1.96113382e-01 9.38989589e-01 9.59250700e-01 1.36490030 0.43967976 185.00 4.10481188e-01 9.22317566e-01 1.00953677e+00 1.15206304 0.42265220 185.25 7.25703387e-01 7.82612745e-01 1.06729945e+00 0.82311067 0.32267572 185.50 5.30318086e-01 -8.93747864e-02 5.37796546e-01 -0.16696161 0.06105058 185.75 -2.96041319e-01 -3.79485082e-01 4.81299689e-01 -2.23329299 0.07039533 186.00 -8.50416309e-01 -1.75653296e-01 8.68367422e-01 -2.93790724 0.26475080 186.25 -6.25384944e-01 1.92014803e-01 6.54198757e-01 2.84369468 0.21215836 186.50 -6.13185784e-01 3.50948830e-01 7.06513897e-01 2.62176209 0.36495661 186.75 -5.78747363e-01 4.59080704e-01 7.38717540e-01 2.47099242 0.31096057 187.00 -6.08225081e-01 5.64396978e-01 8.29747973e-01 2.39355325 0.34406872 187.25 -6.32571913e-01 8.04161127e-01 1.02314336e+00 2.23732738 0.50062766 187.50 -5.63435805e-01 9.71437715e-01 1.12300986e+00 2.09638161 0.65477489 187.75 -4.55325840e-01 1.11414686e+00 1.20359663e+00 1.95876015 0.65282318 188.00 -3.55435229e-01 1.31307565e+00 1.36033153e+00 1.83515030 0.69171148 188.25 -3.02590938e-01 1.17042894e+00 1.20891074e+00 1.82378693 0.55874702 188.50 -2.40964428e-01 1.16044372e+00 1.18519765e+00 1.77553531 0.62357665 188.75 -6.70469551e-02 1.08837589e+00 1.09043907e+00 1.63232134 0.56609851 189.00 -5.94951175e-03 1.08374447e+00 1.08376080e+00 1.57628605 0.59342303 189.25 -1.51715532e-01 6.87550171e-01 7.04090080e-01 1.78797706 0.32273611 189.50 -2.19208557e-01 5.51363113e-01 5.93341111e-01 1.94921102 0.31648974 189.75 -2.85999322e-01 5.05410858e-01 5.80720025e-01 2.08574582 0.28417621 190.00 -3.87681002e-01 5.43540035e-01 6.67631881e-01 2.19036097 0.38064084 190.25 -5.64782505e-01 6.76263863e-01 8.81085745e-01 2.26660642 0.54869978 190.50 -6.00693716e-01 7.26290491e-01 9.42513033e-01 2.26182733 0.66916334 190.75 -6.64398555e-01 8.79196333e-01 1.10200346e+00 2.21792814 0.72923428 191.00 -7.17885087e-01 8.61973529e-01 1.12176529e+00 2.26524274 0.76520597 191.25 -4.20486562e-01 1.13986614e+00 1.21495011e+00 1.92420059 0.64557054 191.50 -2.95033567e-01 1.36218009e+00 1.39376447e+00 1.78409102 0.53521653 191.75 1.67002390e-01 6.55104877e-01 6.76056357e-01 1.32118808 0.10308148 192.00 -1.53236832e-01 -3.06020478e-02 1.56262638e-01 -2.94448148 0.00919725 192.25 -4.04656572e-01 -3.24933590e-02 4.05959061e-01 -3.06146597 0.08536138 192.50 -5.78231890e-01 1.52329477e-01 5.97960189e-01 2.88400501 0.18411412 192.75 -6.06360251e-01 1.48201107e-01 6.24208557e-01 2.90188112 0.27476266 193.00 -5.72357744e-01 1.74635822e-01 5.98407100e-01 2.84544841 0.30871181 193.25 -3.78240916e-01 1.85290051e-01 4.21187124e-01 2.68607933 0.15768898 193.50 -3.38386534e-01 1.19765021e-01 3.58955577e-01 2.80142135 0.13472003 193.75 -5.28641786e-01 1.33132376e-01 5.45148024e-01 2.89488435 0.24842666 194.00 -3.79942827e-01 8.01261890e-02 3.88299830e-01 2.93374809 0.11878520 194.25 -2.70367201e-01 -2.22484728e-02 2.71281068e-01 -3.05948781 0.08285904 194.50 -2.10260035e-01 -3.35608115e-02 2.12921607e-01 -2.98331208 0.05232022 194.75 -2.41753580e-01 -8.29870550e-02 2.55600557e-01 -2.81092479 0.08178052 195.00 -1.49949168e-01 -1.54234783e-01 2.15111880e-01 -2.34210653 0.04474596 195.25 7.14483467e-03 -1.49317579e-01 1.49488422e-01 -1.52298287 0.03100812 195.50 8.23286402e-02 -3.24090089e-01 3.34383598e-01 -1.32202823 0.10218850 195.75 8.23311588e-02 -7.24989523e-01 7.29649387e-01 -1.45771890 0.40138380 196.00 9.09047406e-02 -8.33620684e-01 8.38562530e-01 -1.46217743 0.37842809 196.25 1.09240973e-01 -1.26199138e+00 1.26671064e+00 -1.48444919 0.54683845 196.50 -2.71243854e-01 -1.54773546e+00 1.57132374e+00 -1.74428657 0.59227700 196.75 -9.05369356e-01 -1.92211987e+00 2.12467373e+00 -2.01099764 0.79965773 197.00 -1.24728357e+00 -2.09577101e+00 2.43884654e+00 -2.10763689 0.78888167 197.25 -1.61485433e+00 -2.15631932e+00 2.69396873e+00 -2.21358914 0.85581091 197.50 -1.77837422e+00 -2.22066864e+00 2.84499281e+00 -2.24604210 0.77077001 197.75 -2.41927735e+00 -2.57865477e+00 3.53586811e+00 -2.32431662 0.81735691 198.00 -3.06227444e+00 -1.68121198e+00 3.49342218e+00 -2.63951167 0.70270674 198.25 -4.03448240e+00 -1.26461286e+00 4.22803665e+00 -2.83784156 0.81603142 198.50 -4.20506546e+00 2.31555182e-01 4.21143602e+00 3.08658244 0.72564266 198.75 -4.28726964e+00 1.26921995e+00 4.47119674e+00 2.85376927 0.80810721 199.00 -3.62566322e+00 1.69714359e+00 4.00321498e+00 2.70379578 0.72036189 199.25 -2.77617826e+00 2.24760411e+00 3.57195884e+00 2.46102319 0.69057611 199.50 -1.77105997e+00 2.25996153e+00 2.87125052e+00 2.23549921 0.70259336 199.75 -1.61030169e+00 2.26178316e+00 2.77646080e+00 2.18950487 0.74708888 200.00 -1.26008685e+00 1.75864921e+00 2.16348467e+00 2.19251601 0.66342228 200.25 -8.62164753e-01 1.40182803e+00 1.64573688e+00 2.12219326 0.59954170 200.50 -4.90920527e-01 1.16287539e+00 1.26225280e+00 1.97025978 0.45540667 200.75 -3.76322760e-01 1.09754735e+00 1.16027110e+00 1.90111065 0.42921772 201.00 -4.90098167e-01 7.23664270e-01 8.74005829e-01 2.16608683 0.22982015 201.25 -5.63356380e-01 7.22156240e-01 9.15903950e-01 2.23328677 0.27814349 201.50 -4.63331818e-01 6.31638814e-01 7.83354303e-01 2.20367901 0.24652613 201.75 -4.55135171e-01 6.18697312e-01 7.68071864e-01 2.20504003 0.24814734 202.00 -4.98493771e-01 4.54774098e-01 6.74770717e-01 2.40202532 0.19014808 202.25 -4.63193926e-01 4.58406585e-01 6.51678763e-01 2.36138904 0.19365351 202.50 -2.38913155e-01 4.97237916e-01 5.51656633e-01 2.01870681 0.14863683 202.75 -2.89812985e-01 4.40655694e-01 5.27417299e-01 2.15255560 0.13416481 203.00 -1.20973326e-01 4.87961377e-01 5.02733380e-01 1.81381241 0.10797292 203.25 -1.83519006e-01 5.25974741e-01 5.57071498e-01 1.90650173 0.13572962 203.50 -2.92511639e-01 4.01044010e-01 4.96386298e-01 2.20096651 0.10886923 203.75 -2.13860933e-01 3.82334539e-01 4.38082410e-01 2.08079389 0.08893820 204.00 8.97531175e-02 1.54543376e-01 1.78715632e-01 1.04464158 0.01605637 204.25 3.65563235e-02 8.38872657e-02 9.15064923e-02 1.15983116 0.00530266 204.50 1.47849287e-01 2.06157347e-02 1.49279671e-01 0.13854421 0.01550400 204.75 7.23754302e-02 -2.61553655e-02 7.69565205e-02 -0.34678078 0.00407590 205.00 6.94609537e-03 -6.42121405e-02 6.45867419e-02 -1.46304115 0.00341299 205.25 -1.01422769e-01 -5.66444167e-02 1.16168705e-01 -2.63224846 0.00903057 205.50 -2.50065029e-01 -8.77523715e-02 2.65015089e-01 -2.80410007 0.04890051 205.75 -2.51618124e-01 -3.83689370e-02 2.54526728e-01 -2.99026960 0.03887068 206.00 -2.60061103e-01 2.61262700e-02 2.61370158e-01 3.04146655 0.03759459 206.25 -2.50994418e-01 1.44524057e-01 2.89629765e-01 2.61915296 0.04933316 206.50 -3.78858422e-01 3.91680348e-02 3.80877722e-01 3.03857429 0.11840283 206.75 -4.04857828e-01 9.03633829e-02 4.14819722e-01 2.92199422 0.12040189 207.00 -5.89600265e-01 1.67510540e-01 6.12934135e-01 2.86477807 0.28211112 207.25 -5.17223979e-01 1.22945998e-01 5.31635554e-01 2.90822014 0.20447474 207.50 -4.32660657e-01 1.12989743e-01 4.47171026e-01 2.88614682 0.16754875 207.75 -3.83616655e-01 2.04802529e-01 4.34862983e-01 2.65121536 0.16513590 208.00 -4.88072470e-01 2.52662100e-01 5.49593371e-01 2.66390655 0.29860765 208.25 -4.56960135e-01 1.62928585e-01 4.85137391e-01 2.79909567 0.18713387 208.50 -3.33524339e-01 1.10627020e-01 3.51392690e-01 2.82132093 0.09431543 208.75 -3.38102943e-01 3.60936132e-01 4.94558886e-01 2.32354242 0.11685902 209.00 -1.40073311e-01 3.34188075e-01 3.62356457e-01 1.96769743 0.05223840 209.25 -5.08477372e-02 3.02596903e-01 3.06839336e-01 1.73727884 0.02552308 209.50 -1.23424468e-01 2.65451889e-01 2.92742728e-01 2.00602098 0.01892938 209.75 -2.26014635e-01 3.53450430e-01 4.19535245e-01 2.13972076 0.04615650 210.00 -1.43394904e-01 2.07607054e-01 2.52314858e-01 2.17525569 0.01752845 210.25 2.76136398e-01 2.14407265e-01 3.49602325e-01 0.66021795 0.02983099 210.50 3.60777348e-01 1.94218911e-01 4.09733182e-01 0.49384292 0.04322772 210.75 1.36386440e-01 -3.41202360e-02 1.40589657e-01 -0.24514169 0.00604710 211.00 1.91674566e-01 -3.97352037e-02 1.95749906e-01 -0.20441017 0.01335335 211.25 3.71211332e-02 -2.06125024e-01 2.09440932e-01 -1.39261585 0.01251833 211.50 4.79921757e-02 -3.21308034e-01 3.24872439e-01 -1.42252746 0.02990551 211.75 -6.87767783e-02 1.65016387e-01 1.78775427e-01 1.96569046 0.00950397 212.00 -2.56683969e-01 1.44106347e-01 2.94369325e-01 2.63002744 0.02790325 212.25 -1.09741008e-01 2.94658603e-01 3.14430885e-01 1.92731583 0.02889440 212.50 -3.42735795e-02 3.30703144e-01 3.32474432e-01 1.67406615 0.03808002 212.75 -1.51201530e-01 2.68681965e-01 3.08304883e-01 2.08337781 0.03238368 213.00 -1.35082188e-01 3.03207353e-01 3.31936585e-01 1.98991087 0.03674913 213.25 -1.37595670e-01 1.75538023e-01 2.23038485e-01 2.23561251 0.01840158 213.50 -1.97709604e-01 1.28543890e-01 2.35823280e-01 2.56510136 0.02028122 213.75 -2.50955380e-01 7.09976726e-02 2.60805046e-01 2.86588797 0.02970291 214.00 -1.61119628e-01 4.06227366e-02 1.66161792e-01 2.89461236 0.01062331 214.25 -1.11341500e-02 2.36383926e-01 2.36646001e-01 1.61786352 0.01947651 214.50 -9.09463409e-02 2.80297068e-01 2.94682343e-01 1.88454346 0.02846619 214.75 -9.25794593e-02 1.80886425e-01 2.03201513e-01 2.04384714 0.01267492 215.00 -1.30657387e-01 1.91889111e-01 2.32148193e-01 2.16858848 0.01738907 215.25 -1.39155028e-01 3.09048836e-01 3.38932597e-01 1.99387371 0.03588498 215.50 -5.63388960e-02 2.48202542e-01 2.54516352e-01 1.79400178 0.02298285 215.75 -9.60722892e-02 2.32502633e-01 2.51569789e-01 1.96263806 0.02513624 216.00 -1.17308076e-01 3.11191654e-01 3.32567933e-01 1.93128782 0.04119259 216.25 -8.03333921e-02 3.22906338e-01 3.32749090e-01 1.81462862 0.04669363 216.50 -1.01415031e-01 4.24323578e-01 4.36274578e-01 1.80539934 0.08510722 216.75 -1.23501002e-01 7.17811647e-01 7.28358468e-01 1.74118027 0.23486278 217.00 -1.45064505e-01 6.38018572e-01 6.54302230e-01 1.79436277 0.18935419 217.25 -2.88223914e-01 6.04135058e-01 6.69367009e-01 2.01594465 0.20269414 217.50 -3.21367774e-01 6.17082004e-01 6.95749556e-01 2.05093426 0.18479353 217.75 -3.05658768e-01 6.83072142e-01 7.48341389e-01 1.99154977 0.21875786 218.00 -4.54757075e-01 7.38646286e-01 8.67411282e-01 2.12265309 0.34036586 218.25 -6.87139572e-01 8.07849099e-01 1.06055691e+00 2.27562650 0.49696710 218.50 -5.73884368e-01 7.79182350e-01 9.67712975e-01 2.20561509 0.41689704 218.75 -7.17792150e-01 8.69689198e-01 1.12764572e+00 2.26080060 0.51312318 219.00 -8.10915167e-01 1.05671145e+00 1.33199943e+00 2.22533765 0.60266637 219.25 -8.27117674e-01 1.31866163e+00 1.55659634e+00 2.13100500 0.76806519 219.50 -6.38242549e-01 1.27224621e+00 1.42336361e+00 2.03577577 0.78735158 219.75 -5.51393923e-01 1.30233353e+00 1.41425170e+00 1.97130180 0.82437053 220.00 -4.51818674e-01 1.37254875e+00 1.44500179e+00 1.88880626 0.77684186 220.25 -2.05261818e-01 1.42217092e+00 1.43690728e+00 1.71413641 0.76596708 220.50 2.24561499e-01 1.31732627e+00 1.33632943e+00 1.40195170 0.66914854 220.75 4.21004421e-01 1.23149581e+00 1.30147095e+00 1.24138767 0.68021898 221.00 5.95011374e-01 7.98493517e-01 9.95806423e-01 0.93039523 0.52994139 221.25 6.06872492e-01 5.54805316e-01 8.22254924e-01 0.74060747 0.47912738 221.50 -4.72816837e-02 -1.83344522e-01 1.89342999e-01 -1.82318168 0.03633916 221.75 -3.72292362e-01 -1.64383377e-01 4.06968669e-01 -2.72579313 0.20596351 222.00 -5.27581933e-01 8.03709555e-02 5.33668611e-01 2.99041661 0.31254933 222.25 -4.30303797e-01 2.17594052e-01 4.82191383e-01 2.67341503 0.27147651 222.50 -5.36629848e-01 3.52298159e-01 6.41938927e-01 2.56066071 0.52009214 222.75 -6.58952419e-01 4.01734059e-01 7.71756791e-01 2.59410365 0.69217219 223.00 -7.92327789e-01 4.79345664e-01 9.26042974e-01 2.59751648 0.80258185 223.25 -7.59326170e-01 5.32346485e-01 9.27345141e-01 2.53014391 0.80131024 223.50 -6.57157409e-01 4.99298219e-01 8.25320890e-01 2.49185862 0.82127623 223.75 -6.43149613e-01 5.16054255e-01 8.24592881e-01 2.46539852 0.82534544 224.00 -6.05863577e-01 5.68501289e-01 8.30821515e-01 2.38799865 0.83254197 224.25 -6.55084424e-01 5.59300191e-01 8.61366534e-01 2.43490624 0.83300776 224.50 -6.31595382e-01 6.87474699e-01 9.33559955e-01 2.31385714 0.80138092 224.75 -5.51189350e-01 7.88774968e-01 9.62276285e-01 2.18071085 0.78730764 225.00 -3.82544837e-01 6.97733400e-01 7.95721339e-01 2.07230875 0.79742622 225.25 -3.77018939e-01 6.41277992e-01 7.43895653e-01 2.10228471 0.77136538 225.50 -3.62966498e-01 5.53715729e-01 6.62076874e-01 2.15103564 0.72559342 225.75 -3.29001272e-01 5.08484894e-01 6.05639105e-01 2.14507570 0.69454218 226.00 -3.38503609e-01 5.27101600e-01 6.26434985e-01 2.14166729 0.69880588 226.25 -3.17447082e-01 4.45183128e-01 5.46772957e-01 2.19024087 0.65520176 226.50 -2.74909838e-01 3.07699525e-01 4.12618972e-01 2.29997306 0.60558945 226.75 -2.53897001e-01 2.99310662e-01 3.92492750e-01 2.27428663 0.55021528 227.00 -1.36711867e-01 3.26288896e-01 3.53771930e-01 1.96756567 0.32038841 227.25 5.18386624e-02 2.20183904e-01 2.26203887e-01 1.33957361 0.09327203 227.50 7.33894734e-02 -5.15882227e-01 5.21076278e-01 -1.42948439 0.10919195 227.75 -5.56144542e-01 -7.58831384e-01 9.40809131e-01 -2.20326076 0.31366934 228.00 -1.18185727e+00 -6.03007431e-01 1.32680239e+00 -2.66980237 0.54121863 228.25 -1.19551768e+00 -2.96858250e-01 1.23182277e+00 -2.89820580 0.51486429 228.50 -1.28334180e+00 -2.23242034e-01 1.30261398e+00 -2.96936239 0.68133225 228.75 -1.19981220e+00 -3.34384377e-01 1.24553692e+00 -2.86979238 0.54353155 229.00 -1.14528301e+00 -7.47956772e-01 1.36788614e+00 -2.56305813 0.48297159 229.25 -9.50769001e-01 -1.93828423e-01 9.70325281e-01 -2.94048362 0.16776240 229.50 -8.01641611e-01 1.01082707e+00 1.29011652e+00 2.24128823 0.31632706 229.75 -8.17736273e-01 9.08409680e-01 1.22225233e+00 2.30371333 0.44099410 230.00 -7.57636381e-01 7.17034899e-01 1.04314521e+00 2.38372010 0.43352221 230.25 -7.96728321e-01 4.06048432e-01 8.94232267e-01 2.67025902 0.31226279 230.50 -9.05421644e-01 2.88960279e-01 9.50413802e-01 2.83266599 0.40162185 230.75 -8.89565665e-01 1.75716392e-01 9.06754279e-01 2.94657269 0.25640889 231.00 -1.11615092e+00 1.06097200e-01 1.12118219e+00 3.04682109 0.31431908 231.25 -9.86352479e-01 -4.45806929e-02 9.87359433e-01 -3.09642587 0.23307759 231.50 -9.54735818e-01 -1.16297017e-01 9.61792846e-01 -3.02037914 0.22399391 231.75 -6.34858400e-01 -2.13150701e-01 6.69685306e-01 -2.81767293 0.09118722 232.00 -6.11431017e-01 -4.55475783e-01 7.62434310e-01 -2.50134165 0.09967304 232.25 -4.07832089e-02 -3.30633166e-01 3.33138951e-01 -1.69352521 0.01334352 232.50 4.24931304e-01 -1.87150839e-01 4.64318910e-01 -0.41486381 0.02092065 232.75 5.60845176e-01 7.24626176e-02 5.65506978e-01 0.12849071 0.04810225 233.00 7.35463048e-01 -4.15235673e-03 7.35474769e-01 -0.00564585 0.08498292 233.25 1.14569263e+00 1.06930289e-01 1.15067184e+00 0.09306284 0.28347990 233.50 9.99730952e-01 4.05279774e-01 1.07875561e+00 0.38514328 0.31927168 233.75 1.13985641e+00 5.28070864e-01 1.25623703e+00 0.43384122 0.50579125 234.00 1.10292409e+00 6.12580767e-01 1.26162464e+00 0.50699122 0.54263934 234.25 8.78363997e-01 5.19107420e-01 1.02029203e+00 0.53377076 0.43947560 234.50 9.87201867e-01 5.14549026e-01 1.11325120e+00 0.48047888 0.51349008 234.75 8.36097694e-01 5.91013069e-01 1.02389248e+00 0.61532239 0.64129717 235.00 8.32188097e-01 5.78788911e-01 1.01367334e+00 0.60770113 0.65864168 235.25 8.79988224e-01 5.67473185e-01 1.04709364e+00 0.57275657 0.74504638 235.50 8.05923354e-01 5.28612905e-01 9.63817439e-01 0.58051842 0.67928419 235.75 6.47531296e-01 4.95377907e-01 8.15288936e-01 0.65304824 0.61336044 236.00 4.00045820e-01 4.71833072e-01 6.18597693e-01 0.86754912 0.52840408 236.25 2.75237198e-01 5.16657362e-01 5.85397596e-01 1.08131137 0.54652498 236.50 1.86199367e-01 5.37999863e-01 5.69310158e-01 1.23760407 0.45460551 236.75 -1.13231426e-01 6.91146905e-01 7.00360907e-01 1.73318491 0.46816256 237.00 -3.19036000e-01 8.11700877e-01 8.72148086e-01 1.94529377 0.46379716 237.25 -4.24644051e-01 1.10916930e+00 1.18767803e+00 1.93643025 0.52280755 237.50 -4.03152572e-01 9.95389851e-01 1.07393340e+00 1.95562259 0.34912995 237.75 -7.60559848e-01 6.31216866e-01 9.88375441e-01 2.44886204 0.24300953 238.00 -7.36044831e-01 -1.16792101e-01 7.45253237e-01 -2.98422934 0.10426749 238.25 -2.79668558e-01 -1.35048334e+00 1.37913732e+00 -1.77499765 0.31174873 238.50 2.54318970e-01 -1.41960010e+00 1.44220060e+00 -1.39352846 0.44367063 238.75 3.59936833e-01 -1.36814196e+00 1.41469677e+00 -1.31354133 0.62971079 239.00 4.10557179e-01 -9.45344567e-01 1.03064715e+00 -1.16108025 0.59018640 239.25 4.40183274e-01 -7.04942947e-01 8.31087164e-01 -1.01261134 0.66903862 239.50 5.10600206e-01 -4.64539525e-01 6.90296704e-01 -0.73819829 0.54281748 239.75 5.43897670e-01 -2.44476980e-01 5.96316752e-01 -0.42243037 0.55367900 240.00 6.58166795e-01 -2.37658652e-01 6.99760791e-01 -0.34652181 0.63489432 240.25 7.19705076e-01 -3.02357741e-01 7.80637944e-01 -0.39772438 0.74177823 240.50 8.04832675e-01 -2.24136105e-01 8.35459531e-01 -0.27160592 0.71800140 240.75 9.26024226e-01 -1.16398637e-01 9.33311047e-01 -0.12504139 0.79844414 241.00 1.08510858e+00 -2.15749684e-01 1.10634920e+00 -0.19626813 0.75328049 241.25 1.16078491e+00 -3.70845435e-01 1.21858440e+00 -0.30922951 0.76000001 241.50 9.92360917e-01 -5.50400902e-01 1.13477810e+00 -0.50639695 0.79288555 241.75 9.35032629e-01 -5.86283407e-01 1.10363683e+00 -0.56005000 0.81833471 242.00 9.39909472e-01 -7.72617182e-01 1.21670338e+00 -0.68801973 0.83583881 242.25 9.19747601e-01 -8.49441866e-01 1.25199326e+00 -0.74568011 0.82072295 242.50 8.83253051e-01 -9.29400944e-01 1.28215524e+00 -0.81085141 0.89798364 242.75 8.03818288e-01 -1.01261948e+00 1.29287356e+00 -0.89984675 0.89163950 243.00 5.89435587e-01 -1.08791245e+00 1.23733092e+00 -1.07426721 0.83184855 243.25 4.46002587e-01 -1.17686784e+00 1.25854528e+00 -1.20854596 0.80424522 243.50 1.44718420e-01 -1.15938780e+00 1.16838499e+00 -1.44661548 0.74051163 243.75 -3.37903947e-02 -1.14272333e+00 1.14322282e+00 -1.60035777 0.71181667 244.00 -1.85152880e-01 -1.07027004e+00 1.08616737e+00 -1.74209729 0.64244071 244.25 -2.52418469e-01 -1.07504196e+00 1.10427818e+00 -1.80141753 0.72539856 244.50 -2.50589722e-01 -8.24674364e-01 8.61906616e-01 -1.86579526 0.55340777 244.75 -4.57683200e-01 -7.07223315e-01 8.42400575e-01 -2.14516904 0.42480226 245.00 -8.55016977e-01 -5.13328442e-01 9.97276351e-01 -2.60089951 0.58228949 245.25 -8.82890867e-01 -3.70236135e-01 9.57377188e-01 -2.74452132 0.57253071 245.50 -8.91005974e-01 -1.23160205e-01 8.99477672e-01 -3.00423702 0.52316829 245.75 -7.43893405e-01 -6.58877555e-03 7.43922583e-01 -3.13273574 0.47270595 246.00 -5.43347402e-01 9.39317572e-02 5.51406904e-01 2.97040856 0.32097280 246.25 -4.10852784e-01 1.00893226e-01 4.23059633e-01 2.90078748 0.19649773 246.50 -2.70251727e-01 1.58589285e-01 3.13347343e-01 2.61092024 0.11398560 246.75 -2.90240484e-01 9.80660375e-02 3.06360060e-01 2.81575699 0.10771166 247.00 -2.18824664e-01 2.31304611e-01 3.18411772e-01 2.32847634 0.10181720 247.25 -3.65604047e-02 1.82132611e-01 1.85765850e-01 1.76889860 0.03022284 247.50 -4.13331984e-02 1.28105018e-01 1.34608057e-01 1.88290207 0.01684279 247.75 4.78068052e-02 -6.78884648e-02 8.30321280e-02 -0.95725961 0.00537246 248.00 1.70919149e-01 1.57154642e-01 2.32187289e-01 0.74346723 0.02766843 248.25 1.62618223e-01 2.87658260e-01 3.30442069e-01 1.05626921 0.07360959 248.50 6.97650948e-02 2.38713390e-01 2.48699118e-01 1.28646043 0.05042056 248.75 9.18719297e-02 9.31932999e-02 1.30864214e-01 0.79253807 0.01035488 249.00 -5.50050350e-02 8.29668008e-02 9.95441807e-02 2.15623981 0.00470316 249.25 -2.08869245e-02 -7.17417418e-02 7.47204198e-02 -1.85410542 0.00246875 249.50 1.72060300e-01 -1.58354579e-01 2.33839517e-01 -0.74394159 0.02410791 249.75 3.64212998e-01 -2.16584340e-01 4.23745070e-01 -0.53648669 0.02509594 250.00 3.78321952e-01 -2.34810833e-01 4.45268039e-01 -0.55547525 0.02966910 250.25 -3.06026929e-02 -2.14119840e-01 2.16295702e-01 -1.71275812 0.00978969 250.50 -1.43784649e-01 -3.49828096e-01 3.78224433e-01 -1.96076231 0.03745078 250.75 -3.64877680e-01 -1.93915392e-01 4.13205639e-01 -2.65310028 0.04863214 251.00 -5.16110408e-01 -7.28873314e-02 5.21231730e-01 -3.00129615 0.06123915 251.25 -4.49679589e-01 -1.92437301e-01 4.89125595e-01 -2.73723177 0.07611831 251.50 -2.55796593e-01 -4.25494677e-02 2.59311308e-01 -2.97676083 0.03637738 251.75 -1.61140727e-01 9.26680778e-02 1.85886273e-01 2.61970167 0.02065839 252.00 -9.34896417e-02 5.68722441e-03 9.36624665e-02 3.08083486 0.00453235 252.25 2.59492919e-01 -2.61290999e-01 3.68252035e-01 -0.78885079 0.12624873 252.50 2.77282470e-01 -4.32786451e-01 5.13993852e-01 -1.00099294 0.24140396 252.75 -1.74400439e-02 -5.85473738e-01 5.85733432e-01 -1.60057544 0.37404919 253.00 -8.27814067e-02 -7.84742780e-01 7.89096947e-01 -1.67589622 0.53127897 253.25 -1.45060027e-01 -6.71792447e-01 6.87275421e-01 -1.78346106 0.38919979 253.50 -3.67925321e-01 -7.28208607e-01 8.15877943e-01 -2.03863284 0.45482083 253.75 -7.91755692e-01 -6.36546745e-01 1.01590789e+00 -2.46443649 0.50546210 254.00 -8.75368877e-01 -5.24091531e-01 1.02026595e+00 -2.60212270 0.57682408 254.25 -8.26766229e-01 -4.93415087e-01 9.62808831e-01 -2.60352852 0.55330091 254.50 -8.06453978e-01 -4.01637782e-01 9.00933364e-01 -2.67952278 0.55487240 254.75 -7.52471719e-01 -2.78421182e-01 8.02329136e-01 -2.78720497 0.59419483 255.00 -7.62913486e-01 -1.87883211e-01 7.85708017e-01 -2.90012702 0.63278943 255.25 -7.65146638e-01 -1.37516723e-01 7.77406089e-01 -2.96376516 0.60080399 255.50 -8.20842813e-01 -9.56111283e-02 8.26392407e-01 -3.02563596 0.65465467 255.75 -8.75136986e-01 -1.82982990e-01 8.94062368e-01 -2.93547153 0.65434834 256.00 -9.17038208e-01 -1.76401871e-01 9.33850467e-01 -2.95155350 0.63379667 256.25 -8.74399642e-01 -2.28387824e-01 9.03734326e-01 -2.88610665 0.46182449 256.50 -1.04422683e+00 -1.52500969e-01 1.05530385e+00 -2.99657585 0.48579428 256.75 -1.41224138e+00 2.48662467e-01 1.43396609e+00 2.96730270 0.54047906 257.00 -1.34985618e+00 5.54004194e-01 1.45912040e+00 2.75213831 0.60994864 257.25 -8.71550379e-01 8.40361888e-01 1.21070565e+00 2.37441099 0.65947369 257.50 -6.85465634e-01 8.53038722e-01 1.09432088e+00 2.24770269 0.58819796 257.75 -5.67363462e-01 8.48309637e-01 1.02055404e+00 2.16028578 0.59827731 258.00 -4.99210520e-01 7.61717616e-01 9.10727659e-01 2.15094068 0.58262292 258.25 -4.02132825e-01 7.73268699e-01 8.71582061e-01 2.05034931 0.61028724 258.50 -3.01796295e-01 7.85914930e-01 8.41868922e-01 1.93743947 0.59965031 258.75 -2.42088711e-01 6.86292603e-01 7.27739295e-01 1.90991763 0.64131741 259.00 -2.11893227e-01 5.26197935e-01 5.67259205e-01 1.95361720 0.52979565 259.25 -9.81293305e-02 4.00168637e-01 4.12024639e-01 1.81127108 0.45482791 259.50 -1.53404357e-01 4.00193010e-01 4.28587614e-01 1.93684639 0.40202122 259.75 -2.89416172e-01 4.07859417e-01 5.00111012e-01 2.18793481 0.49293050 260.00 -2.78020738e-01 4.02983765e-01 4.89582930e-01 2.17471532 0.41784967 260.25 -2.61196284e-01 4.32304323e-01 5.05084673e-01 2.11429497 0.49727710 260.50 -2.57448636e-01 4.76873827e-01 5.41930297e-01 2.06582693 0.50626580 260.75 -3.29525489e-01 5.57960648e-01 6.48002417e-01 2.10426733 0.61540131 261.00 -3.16986565e-01 5.79534936e-01 6.60561295e-01 2.07130806 0.48980639 261.25 -3.36833109e-01 6.55992676e-01 7.37416391e-01 2.04516244 0.65336846 261.50 -1.55768646e-01 7.43190623e-01 7.59339300e-01 1.77740009 0.59506114 261.75 5.96654436e-02 7.14143296e-01 7.16631434e-01 1.48744163 0.60671705 262.00 2.01060234e-01 6.12280796e-01 6.44447818e-01 1.25351116 0.63175541 262.25 2.47786697e-01 5.72539006e-01 6.23858286e-01 1.16234964 0.73504805 262.50 2.37444226e-01 4.94282842e-01 5.48356899e-01 1.12296651 0.68668838 262.75 2.20011638e-01 4.08909512e-01 4.64340510e-01 1.07717808 0.68037593 263.00 2.44112987e-01 3.54371419e-01 4.30314133e-01 0.96758474 0.62834433 263.25 2.32245949e-01 3.26644063e-01 4.00792371e-01 0.95272179 0.61032342 263.50 1.70868797e-01 3.17849021e-01 3.60865828e-01 1.07753977 0.60505422 263.75 1.34162332e-01 3.08109471e-01 3.36052045e-01 1.16011858 0.67801299 264.00 1.06540210e-01 2.65211698e-01 2.85811233e-01 1.18881013 0.63498027 264.25 1.03307762e-01 2.56663225e-01 2.76674005e-01 1.18813391 0.70343285 264.50 9.13875557e-02 2.63676065e-01 2.79064066e-01 1.23716236 0.61794408 264.75 1.16151707e-01 2.58794916e-01 2.83665344e-01 1.14892614 0.62453345 265.00 1.00741628e-01 2.00733709e-01 2.24594963e-01 1.10565622 0.56073515 265.25 8.23700097e-02 2.01127744e-01 2.17341178e-01 1.18209231 0.56594502 265.50 5.05491264e-02 2.49766100e-01 2.54829980e-01 1.37110773 0.62118936 265.75 4.39301165e-02 2.34327655e-01 2.38409951e-01 1.38547443 0.59613923 266.00 9.13139941e-02 1.87843940e-01 2.08862614e-01 1.11831727 0.48382591 266.25 8.66582637e-02 2.03230474e-01 2.20935014e-01 1.16773718 0.52167351 266.50 7.68850041e-02 2.15677827e-01 2.28972114e-01 1.22835967 0.65531666 266.75 6.95324760e-02 2.04771331e-01 2.16254626e-01 1.24345087 0.58714276 267.00 2.73974668e-02 2.20854852e-01 2.22547719e-01 1.44737494 0.61505410 267.25 5.74847788e-02 2.22059380e-01 2.29379311e-01 1.31748588 0.58874240 267.50 1.19318047e-01 1.65511280e-01 2.04036222e-01 0.94617696 0.53480596 267.75 1.04145470e-01 1.77566164e-01 2.05854369e-01 1.04035023 0.44149993 268.00 6.65336246e-02 1.01677956e-01 1.21511851e-01 0.99136468 0.22125772 268.25 5.82658627e-02 5.55330485e-02 8.04911811e-02 0.76138836 0.10750940 268.50 5.46835553e-03 2.13486364e-02 2.20378581e-02 1.32004215 0.01058996 268.75 -6.95820832e-02 4.38341669e-02 8.22380720e-02 2.57943210 0.11213965 269.00 -1.59822452e-01 6.58906877e-02 1.72872204e-01 2.75054998 0.45171315 269.25 -1.80339699e-01 8.71490806e-02 2.00293208e-01 2.69143497 0.48474131 269.50 -1.95375894e-01 1.95463009e-01 2.76364846e-01 2.35597160 0.56032859 269.75 -1.99944905e-01 3.08855765e-01 3.67926417e-01 2.14532263 0.63268577 270.00 -1.90338574e-01 3.80246316e-01 4.25224686e-01 2.03489705 0.71481852 270.25 -1.80612256e-01 3.98427364e-01 4.37453027e-01 1.99640183 0.70873071 270.50 -1.41849139e-01 3.71274262e-01 3.97449061e-01 1.93574240 0.59327978 270.75 -1.18241857e-02 4.45274893e-01 4.45431860e-01 1.59734489 0.59608595 271.00 6.34090638e-02 5.23183006e-01 5.27011543e-01 1.45018595 0.73306282 271.25 -1.21958939e-03 6.25784745e-01 6.25785933e-01 1.57274522 0.72980088 271.50 3.46347128e-02 7.67874778e-01 7.68655474e-01 1.52572224 0.77598199 271.75 1.84876147e-01 8.75034604e-01 8.94351580e-01 1.36257979 0.74862626 272.00 3.72305023e-01 1.08127377e+00 1.14357510e+00 1.23918988 0.76244788 272.25 7.33160813e-01 1.19254139e+00 1.39988562e+00 1.01957379 0.72031939 272.50 1.15871926e+00 1.05130131e+00 1.56456536e+00 0.73683143 0.69132663 272.75 1.69984339e+00 5.51246102e-01 1.78699183e+00 0.31359166 0.63098607 273.00 2.09169591e+00 -8.96934269e-02 2.09361809e+00 -0.04285447 0.62097269 273.25 1.61176538e+00 -3.82186775e-01 1.65645838e+00 -0.23282298 0.45343490 273.50 1.45009798e+00 -5.15676847e-01 1.53906035e+00 -0.34166842 0.36726076 273.75 7.03161033e-01 -7.17846708e-01 1.00485787e+00 -0.79573249 0.11797875 274.00 1.65477838e-01 -8.82486177e-01 8.97866787e-01 -1.38543559 0.10434950 274.25 -6.48913734e-01 -5.64220495e-01 8.59903367e-01 -2.42589497 0.08654578 274.50 -1.35916932e+00 -6.43910072e-01 1.50398185e+00 -2.69916253 0.23582479 274.75 -1.00601578e+00 -8.13209630e-01 1.29359099e+00 -2.46178288 0.38221875 275.00 -1.28046432e+00 -5.97866094e-01 1.41316408e+00 -2.70476281 0.51392980 275.25 -1.38814533e+00 -1.16589693e-01 1.39303289e+00 -3.05779977 0.54538105 275.50 -1.37260523e+00 1.03675073e-02 1.37264438e+00 3.13403964 0.51183468 275.75 -1.19058502e+00 1.01241280e-01 1.19488179e+00 3.05676183 0.42339387 276.00 -1.18696750e+00 2.53927726e-01 1.21382500e+00 2.93083963 0.48361402 276.25 -9.55831132e-01 3.81825413e-01 1.02927343e+00 2.76154366 0.35225102 276.50 -7.87581573e-01 6.28012163e-01 1.00731525e+00 2.46844327 0.33080168 276.75 -5.69910018e-01 9.10710316e-01 1.07433268e+00 2.12996085 0.38120540 277.00 -3.57114315e-01 8.31637773e-01 9.05070174e-01 1.97639710 0.35434594 277.25 1.80142843e-01 9.34944492e-01 9.52141085e-01 1.38045137 0.44815530 277.50 2.83416139e-01 8.63130965e-01 9.08471118e-01 1.25353005 0.56276804 277.75 2.65290960e-01 8.27884708e-01 8.69351702e-01 1.26069038 0.68308912 278.00 2.56913565e-01 7.61789195e-01 8.03944872e-01 1.24552474 0.69102430 278.25 2.10107110e-01 6.32652161e-01 6.66628648e-01 1.25015145 0.71350011 278.50 2.37641966e-01 5.71822009e-01 6.19236719e-01 1.17692525 0.74479366 278.75 3.46742158e-01 6.01616769e-01 6.94386680e-01 1.04794766 0.84806865 279.00 4.64472751e-01 5.31531448e-01 7.05875780e-01 0.85262443 0.79525343 279.25 4.46979956e-01 3.07463093e-01 5.42516944e-01 0.60253702 0.77386041 279.50 3.72241243e-01 2.31435292e-01 4.38321614e-01 0.55624778 0.76950109 279.75 2.99468270e-01 1.67301783e-01 3.43032260e-01 0.50946978 0.79147704 280.00 2.39157247e-01 1.63567735e-01 2.89742286e-01 0.59986173 0.67523060 280.25 1.89683038e-01 1.61853487e-01 2.49351572e-01 0.70639747 0.60082000 280.50 1.39399211e-01 1.74889037e-01 2.23647749e-01 0.89784310 0.52716973 280.75 9.78919770e-02 1.73110739e-01 1.98872238e-01 1.05614025 0.62355027 281.00 9.83507371e-02 1.71880300e-01 1.98029556e-01 1.05106523 0.55934920 281.25 8.69660377e-02 1.77417642e-01 1.97585707e-01 1.11503800 0.63496376 281.50 1.01274220e-01 1.48718734e-01 1.79927011e-01 0.97295105 0.50796526 281.75 1.14904731e-01 1.45899101e-01 1.85713879e-01 0.90368507 0.59342042 282.00 8.17166372e-02 1.59831325e-01 1.79509502e-01 1.09817503 0.52399640 282.25 7.37376969e-02 1.57827556e-01 1.74203287e-01 1.13372785 0.54274624 282.50 6.13704178e-02 1.51932543e-01 1.63859165e-01 1.18690489 0.51329481 282.75 5.19351516e-02 1.44999580e-01 1.54019928e-01 1.22685775 0.62005116 283.00 6.37990952e-02 1.73405545e-01 1.84769607e-01 1.21824857 0.64492187 283.25 5.90528196e-02 1.75071620e-01 1.84762841e-01 1.24547407 0.66588749 283.50 6.29383726e-02 2.02648124e-01 2.12196844e-01 1.26966196 0.68055019 283.75 5.56463618e-02 2.10200034e-01 2.17440962e-01 1.31200242 0.71702342 284.00 1.00897100e-01 2.35610218e-01 2.56305286e-01 1.16618680 0.71363572 284.25 1.27189538e-01 2.29747177e-01 2.62604158e-01 1.06518840 0.72162083 284.50 1.70915182e-01 2.04245585e-01 2.66323597e-01 0.87400850 0.77508537 284.75 1.85732213e-01 1.77920323e-01 2.57200498e-01 0.76391973 0.80986832 285.00 1.95384213e-01 1.26424689e-01 2.32719128e-01 0.57430343 0.77139800 285.25 2.02963579e-01 1.07602178e-01 2.29722536e-01 0.48747967 0.78331259 285.50 1.81426050e-01 6.77533725e-02 1.93664481e-01 0.35741017 0.75355917 285.75 1.75881177e-01 6.01785015e-02 1.85891475e-01 0.32966831 0.81364113 286.00 1.50224144e-01 6.64530428e-02 1.64265944e-01 0.41648175 0.79197197 286.25 1.44389404e-01 5.48683904e-02 1.54463071e-01 0.36314953 0.75236457 286.50 1.54782885e-01 4.01297971e-02 1.59900413e-01 0.25367955 0.78603639 286.75 1.47654279e-01 4.07291004e-02 1.53168684e-01 0.26914789 0.80630864 287.00 1.25625454e-01 3.72269683e-02 1.31025196e-01 0.28808919 0.75101973 287.25 1.16807837e-01 3.73737618e-02 1.22641220e-01 0.30966609 0.73121389 287.50 1.09200603e-01 3.47563908e-02 1.14598335e-01 0.30814212 0.72285974 287.75 1.14006785e-01 3.21747551e-02 1.18459959e-01 0.27506417 0.70549022 288.00 1.11495404e-01 2.03559254e-03 1.11513985e-01 0.01825516 0.74530535 288.25 1.07793966e-01 1.19674735e-03 1.07800609e-01 0.01110172 0.72872257 288.50 1.03101602e-01 -1.77062254e-04 1.03101754e-01 -0.00171736 0.77805402 288.75 1.03851264e-01 -5.71781804e-04 1.03852838e-01 -0.00550572 0.72756918 289.00 8.94309709e-02 -5.01392675e-03 8.95714130e-02 -0.05600614 0.70730382 289.25 9.46606859e-02 -9.60075238e-03 9.51463079e-02 -0.10107717 0.71007077 289.50 1.00474879e-01 -1.08213587e-02 1.01055941e-01 -0.10728857 0.71831826 289.75 8.44067973e-02 -5.88093864e-03 8.46114229e-02 -0.06956134 0.63167156 290.00 6.55979000e-02 -1.14209718e-02 6.65847061e-02 -0.17237786 0.65861206 290.25 7.05946558e-02 -1.85007825e-02 7.29786571e-02 -0.25630655 0.60584284 290.50 8.57292136e-02 -1.64405429e-02 8.72914058e-02 -0.18947255 0.72589620 290.75 7.86786233e-02 -2.10893392e-02 8.14560372e-02 -0.26188792 0.57576529 291.00 8.05374301e-02 -3.18720676e-02 8.66147005e-02 -0.37683056 0.63527313 291.25 6.83049759e-02 -3.17126167e-02 7.53077672e-02 -0.43466530 0.49513999 291.50 5.78570295e-02 -2.86847733e-02 6.45774890e-02 -0.46027167 0.52522233 291.75 4.95107364e-02 -3.37573785e-02 5.99238986e-02 -0.59841970 0.43769599 292.00 3.90853616e-02 -4.28562626e-02 5.80027993e-02 -0.83138508 0.45122081 292.25 3.19498988e-02 -3.41811693e-02 4.67883358e-02 -0.81912549 0.23714239 292.50 3.34632034e-02 -2.59998681e-02 4.23766342e-02 -0.66053897 0.23373686 292.75 1.70925517e-02 -4.15165053e-02 4.48973889e-02 -1.18024036 0.20259971 293.00 3.80569120e-03 -5.64406767e-02 5.65688366e-02 -1.50347007 0.29059099 293.25 3.64782493e-03 -5.30960964e-02 5.32212559e-02 -1.50220180 0.20319687 293.50 -7.46521233e-03 -3.63723124e-02 3.71305064e-02 -1.77322943 0.13522456 293.75 -2.87981462e-03 -3.07856518e-02 3.09200532e-02 -1.66406895 0.09646416 294.00 -4.59340644e-03 -2.33902430e-02 2.38370059e-02 -1.76470996 0.05178938 294.25 -2.34879387e-02 -2.40744091e-02 3.36342153e-02 -2.34386455 0.09840657 294.50 -3.44871382e-02 -8.97935677e-03 3.56369408e-02 -2.88687967 0.10323013 294.75 -2.30109198e-02 -1.68115092e-03 2.30722495e-02 -3.06866339 0.02857857 295.00 -2.95795799e-02 1.26793944e-02 3.21825820e-02 2.73663142 0.06268743 295.25 -4.51530908e-02 1.03541678e-02 4.63250516e-02 2.91617733 0.11019248 295.50 -3.74926965e-02 3.52539854e-02 5.14640241e-02 2.38695884 0.12576705 295.75 -2.80475206e-02 5.14107472e-02 5.85638826e-02 2.07022242 0.10017317 296.00 -2.70189253e-02 7.62842086e-02 8.09277629e-02 1.91119692 0.15919667 296.25 -5.03624826e-03 5.30135366e-02 5.32522193e-02 1.66551137 0.06819988 296.50 5.03825363e-03 6.06135344e-02 6.08225661e-02 1.48786603 0.09413168 296.75 5.25959560e-02 5.24521283e-02 7.42802824e-02 0.78402900 0.22348953 297.00 4.78608972e-02 5.41513299e-02 7.22705473e-02 0.84698370 0.21797040 297.25 4.28006179e-02 5.66250046e-02 7.09808709e-02 0.92355488 0.21271356 297.50 4.51771811e-02 4.39474729e-02 6.30266457e-02 0.77160142 0.17405176 297.75 4.75932812e-02 4.27552506e-02 6.39775888e-02 0.73190073 0.17043089 298.00 3.64155477e-02 4.09957764e-02 5.48338016e-02 0.84449669 0.11456948 298.25 5.26744828e-02 1.50005799e-02 5.47687733e-02 0.27743463 0.12554437 298.50 3.82751884e-02 2.16642509e-02 4.39810166e-02 0.51505402 0.07331589 298.75 1.18834589e-02 3.23297797e-02 3.44446114e-02 1.21855544 0.03893006 299.00 3.15185021e-03 3.75318804e-02 3.76639909e-02 1.48701496 0.02817403 299.25 3.77610811e-02 6.57434433e-02 7.58162224e-02 1.04943541 0.10337389 299.50 8.27608273e-02 7.51419089e-02 1.11783993e-01 0.73718485 0.18933464 299.75 1.51554562e-01 6.13432164e-02 1.63498549e-01 0.38460303 0.39130479 300.00 1.28558708e-01 3.65936386e-02 1.33665388e-01 0.27731112 0.23757527 300.25 1.24024581e-01 6.16001820e-02 1.38479887e-01 0.46098584 0.25129740 300.50 1.30615247e-01 5.09642626e-02 1.40205916e-01 0.37201765 0.29454408 300.75 1.32929290e-01 3.33227160e-02 1.37042328e-01 0.24561857 0.39302299 301.00 1.36717008e-01 3.32493164e-02 1.40702016e-01 0.23856670 0.35290264 301.25 8.55242359e-02 2.73993325e-02 8.98060040e-02 0.31003783 0.14550418 301.50 1.00098885e-01 2.72255353e-02 1.03735319e-01 0.26556234 0.16568524 301.75 1.20327121e-01 3.96264242e-02 1.26684133e-01 0.31813644 0.24190119 302.00 1.10459628e-01 5.69449548e-02 1.24274121e-01 0.47599216 0.13647037 302.25 1.57043063e-01 8.30344815e-02 1.77643600e-01 0.48637206 0.20402652 302.50 1.84348038e-01 -2.35074363e-02 1.85840789e-01 -0.12683211 0.24844230 302.75 2.14857220e-01 -4.13661679e-02 2.18803073e-01 -0.19020134 0.36472126 303.00 2.00045805e-01 -1.76865706e-02 2.00826141e-01 -0.08818331 0.26602554 303.25 2.05276397e-01 -4.85701144e-02 2.10944199e-01 -0.23233561 0.29156213 303.50 2.00168570e-01 -4.56291786e-02 2.05303382e-01 -0.22412409 0.27599248 303.75 2.22700056e-01 -2.52955491e-02 2.24132059e-01 -0.11310100 0.35464704 304.00 1.56084225e-01 -5.51707061e-02 1.65547854e-01 -0.33976059 0.17325543 304.25 1.52737556e-01 -4.75492537e-02 1.59967786e-01 -0.30180351 0.18530679 304.50 9.99015660e-02 -9.24213888e-02 1.36095687e-01 -0.74652392 0.11164066 304.75 1.30571088e-01 -6.52751810e-02 1.45978280e-01 -0.46358411 0.11752832 305.00 1.53105526e-01 -5.66637741e-02 1.63254664e-01 -0.35446454 0.12491253 305.25 1.54114189e-01 -5.94020583e-02 1.65165940e-01 -0.36789360 0.12370329 305.50 1.24355500e-01 -6.89817293e-02 1.42206784e-01 -0.50645515 0.05184628 305.75 1.40544440e-01 -1.75896733e-01 2.25149728e-01 -0.89665520 0.10763796 306.00 -5.88817326e-03 -2.16555172e-01 2.16635207e-01 -1.59797981 0.09701378 306.25 -9.43867724e-02 -2.51396002e-01 2.68530841e-01 -1.92996196 0.17020571 306.50 -2.04676551e-01 -2.04779691e-01 2.89529294e-01 -2.35594260 0.24693550 306.75 -2.26542401e-01 -1.99076456e-01 3.01583976e-01 -2.42063692 0.32275872 307.00 -1.61382965e-01 -1.98674855e-01 2.55961246e-01 -2.25299052 0.37412790 307.25 -1.65713026e-01 -2.01810942e-01 2.61129208e-01 -2.25828930 0.39666007 307.50 -1.24552200e-01 -1.79834456e-01 2.18754845e-01 -2.17653427 0.41839940 307.75 -1.21528640e-01 -1.96020501e-01 2.30636613e-01 -2.12577705 0.51588941 308.00 -1.03153588e-01 -1.88544728e-01 2.14918071e-01 -2.07141346 0.45067551 308.25 -1.09325630e-01 -1.74336514e-01 2.05779769e-01 -2.13090104 0.40759675 308.50 -7.15967849e-02 -1.63649823e-01 1.78626325e-01 -1.98320670 0.38256010 308.75 -7.18167443e-02 -1.58161249e-01 1.73702693e-01 -1.99703215 0.36658900 309.00 -1.09716736e-01 -1.65784962e-01 1.98802454e-01 -2.15542317 0.51873453 309.25 -1.17469035e-01 -1.59949348e-01 1.98450922e-01 -2.20424752 0.42643244 309.50 -6.23677652e-02 -1.62620492e-01 1.74169924e-01 -1.93701319 0.44240078 309.75 -6.64403727e-02 -1.43301096e-01 1.57954193e-01 -2.00493666 0.38463536 310.00 -6.27751688e-02 -1.49464699e-01 1.62112362e-01 -1.96842429 0.46649572 310.25 -6.55864717e-02 -1.47734158e-01 1.61638382e-01 -1.98860709 0.38796486 310.50 -4.77345308e-02 -1.49649146e-01 1.57077854e-01 -1.87957038 0.38519088 310.75 4.18026042e-03 -1.71353257e-01 1.71404240e-01 -1.54640559 0.38034911 311.00 6.64026425e-02 -2.07492381e-01 2.17858667e-01 -1.26107117 0.54337291 311.25 6.01082768e-02 -3.07534006e-01 3.13353107e-01 -1.37777720 0.59845580 311.50 9.84680542e-02 -4.22335696e-01 4.33662769e-01 -1.34173717 0.74928453 311.75 1.15536783e-01 -4.66631409e-01 4.80721978e-01 -1.32808009 0.62857971 312.00 1.57434475e-01 -6.04487355e-01 6.24652365e-01 -1.31601340 0.71879480 312.25 1.59908098e-01 -6.56649712e-01 6.75839807e-01 -1.33192463 0.57646649 312.50 1.27695608e-01 -7.45847596e-01 7.56699943e-01 -1.40123164 0.44353170 312.75 -1.00493177e-01 -6.01585408e-01 6.09921209e-01 -1.73631526 0.17839571 313.00 -4.10571733e-01 -2.31543882e-01 4.71361557e-01 -2.62809878 0.07122721 313.25 -3.10194194e-01 2.33820213e-02 3.11074199e-01 3.06635628 0.03791660 313.50 -2.32513157e-01 1.85878651e-01 2.97679763e-01 2.46719764 0.03350469 313.75 2.73372815e-01 6.85576212e-01 7.38070076e-01 1.19136888 0.25526610 314.00 3.54932838e-01 7.66308836e-01 8.44515572e-01 1.13704267 0.47335260 314.25 1.37598725e-01 4.99593041e-01 5.18195538e-01 1.30203818 0.54572640 314.50 8.20004975e-02 4.74002150e-01 4.81042742e-01 1.39949573 0.69793553 314.75 5.96947791e-02 3.88893463e-01 3.93448335e-01 1.41848609 0.62371185 315.00 3.91534120e-02 3.43556682e-01 3.45780542e-01 1.45732098 0.62856402 315.25 -1.79949986e-03 3.04270173e-01 3.04275495e-01 1.57671041 0.62334471 315.50 2.37009861e-03 2.77710908e-01 2.77721021e-01 1.56226212 0.60278090 315.75 4.98779887e-02 2.94355014e-01 2.98550981e-01 1.40294232 0.62090531 316.00 4.45509791e-02 2.72849733e-01 2.76462957e-01 1.40894432 0.58367663 316.25 3.08197803e-02 1.97014359e-01 1.99410422e-01 1.41561980 0.43367927 316.50 9.48515529e-03 1.81077975e-01 1.81326228e-01 1.51846255 0.43847105 316.75 -6.70031482e-02 1.85398526e-01 1.97134561e-01 1.91759131 0.45778501 317.00 -8.15152696e-02 1.74537689e-01 1.92634743e-01 2.00772619 0.45141640 317.25 -6.37804782e-02 1.79739839e-01 1.90720631e-01 1.91178430 0.50068707 317.50 -6.24875298e-02 1.85269567e-01 1.95523666e-01 1.89609375 0.53188729 317.75 -6.55364033e-02 1.92675249e-01 2.03516023e-01 1.89865960 0.49376085 318.00 -3.79649749e-02 2.12564415e-01 2.15928159e-01 1.74753730 0.50427713 318.25 -1.68008040e-02 2.26805582e-01 2.27426997e-01 1.64473708 0.53472926 318.50 2.98005292e-02 2.11518418e-01 2.13607380e-01 1.43082900 0.46261073 318.75 1.00185139e-01 2.75505217e-01 2.93155567e-01 1.22202076 0.42974402 319.00 1.21957849e-01 2.66332547e-01 2.92927880e-01 1.14137925 0.45387201 319.25 5.62041242e-02 2.68196030e-01 2.74021922e-01 1.36422214 0.50428172 319.50 1.09334431e-01 2.25432469e-01 2.50547034e-01 1.11922170 0.41162845 319.75 1.75053387e-01 1.53185897e-01 2.32614719e-01 0.71887589 0.39822504 320.00 1.23055979e-01 1.31884938e-01 1.80378521e-01 0.82001572 0.23299441 320.25 1.02510453e-01 1.38545545e-01 1.72346340e-01 0.93378780 0.16401788 320.50 1.54319842e-01 1.68260187e-01 2.28311419e-01 0.82858644 0.26258087 320.75 1.94299429e-01 1.42799815e-01 2.41130784e-01 0.63379749 0.34833948 321.00 2.25756938e-01 1.40359372e-01 2.65832557e-01 0.55624283 0.31259060 321.25 2.50467232e-01 9.85138213e-02 2.69144585e-01 0.37473470 0.20100402 321.50 2.85429637e-01 2.82728921e-02 2.86826488e-01 0.09873174 0.23587742 321.75 2.36841005e-01 -7.30028786e-02 2.47836805e-01 -0.29899535 0.23433818 322.00 1.75209692e-01 -6.95584455e-02 1.88512104e-01 -0.37791847 0.16113428 322.25 5.60229683e-02 -5.78913902e-02 8.05604495e-02 -0.80179868 0.03539379 322.50 2.99032935e-02 -6.18441999e-02 6.86943376e-02 -1.12041437 0.03483007 322.75 1.01829295e-02 -1.07155563e-01 1.07638315e-01 -1.47605144 0.14674152 323.00 -1.41450510e-02 -1.07093877e-01 1.08023983e-01 -1.70211706 0.20814765 323.25 -2.31930723e-02 -9.27382218e-02 9.55944370e-02 -1.81586142 0.25848927 323.50 -5.30910351e-02 -5.40835795e-02 7.57871465e-02 -2.34693375 0.20143033 323.75 -7.27721730e-02 -4.67070768e-02 8.64716149e-02 -2.57098509 0.29090403 324.00 -5.36130951e-02 -2.76002415e-02 6.03003922e-02 -2.66617202 0.13996325 324.25 -4.59636054e-02 -2.93225218e-03 4.60570421e-02 -3.07788390 0.10738418 324.50 -5.94466194e-02 1.55852223e-02 6.14556727e-02 2.88519147 0.20394095 324.75 -5.73327034e-02 1.11671912e-02 5.84101450e-02 2.94922255 0.21678018 325.00 -3.29548419e-02 1.11424099e-02 3.47875683e-02 2.81554796 0.08702963 325.25 -2.65812453e-02 2.83818695e-02 3.88856415e-02 2.32344561 0.11659411 325.50 -3.60078259e-02 3.65677428e-02 5.13202040e-02 2.34847969 0.18054871 325.75 -3.20567018e-02 4.58252850e-02 5.59248503e-02 2.18121470 0.25275227 326.00 -1.95645103e-02 3.38020706e-02 3.90557299e-02 2.09547888 0.12685842 326.25 -1.57856323e-02 3.12311149e-02 3.49938383e-02 2.03879099 0.09588000 326.50 -9.94346610e-03 2.89433242e-02 3.06037340e-02 1.90171313 0.11496278 326.75 -1.35713573e-02 2.47815222e-02 2.82543020e-02 2.07182597 0.13151622 327.00 -5.82476487e-04 2.74724291e-02 2.74786034e-02 1.59199537 0.11402913 327.25 4.94483433e-03 2.47065560e-02 2.51965335e-02 1.37326366 0.12874721 327.50 -9.45284653e-03 9.28925124e-03 1.32531693e-02 2.36492303 0.03419661 327.75 -2.01620826e-02 1.74245422e-04 2.01628355e-02 3.13295064 0.07085128 328.00 -1.06468886e-02 1.44009066e-02 1.79092810e-02 2.20742759 0.03148656 328.25 -2.08620261e-02 1.91611303e-02 2.83261902e-02 2.39866673 0.08152672 328.50 -2.56473657e-02 2.38435157e-02 3.50185752e-02 2.39262649 0.12084330 328.75 -9.13277720e-03 1.78937023e-02 2.00896043e-02 2.04272181 0.04280863 329.00 6.13739426e-03 4.40173547e-03 7.55267393e-03 0.62217616 0.00963705 329.25 -2.81207338e-03 7.05023344e-03 7.59035890e-03 1.95032167 0.00932502 329.50 3.58696045e-03 9.52378096e-03 1.01768703e-02 1.21059565 0.02069902 329.75 2.70705861e-03 1.52394238e-02 1.54779910e-02 1.39499488 0.04561574 330.00 -1.14388217e-03 1.96824911e-02 1.97157024e-02 1.62884777 0.06898482 330.25 -1.10479848e-02 2.84637204e-02 3.05326276e-02 1.94103927 0.12336936 330.50 -1.32502634e-02 2.71718698e-02 3.02304480e-02 2.02451227 0.16787626 330.75 -4.63153680e-03 3.73678736e-02 3.76538061e-02 1.69411178 0.20737024 331.00 4.65421793e-03 3.14016468e-02 3.17446872e-02 1.42365184 0.20458582 331.25 1.94486758e-02 2.19910678e-02 2.93574191e-02 0.84667290 0.15313646 331.50 4.26583862e-02 4.57396435e-03 4.29029028e-02 0.10681500 0.34233972 331.75 4.07026955e-02 -5.70867500e-03 4.11010753e-02 -0.13934407 0.31603970 332.00 3.48849061e-02 -1.38834897e-02 3.75460778e-02 -0.37876366 0.39181369 332.25 3.76358981e-02 -2.28777049e-02 4.40437307e-02 -0.54618563 0.42510100 332.50 4.02098951e-02 -4.05538480e-02 5.71091083e-02 -0.78965689 0.55901289 332.75 3.02525337e-02 -5.40988460e-02 6.19830698e-02 -1.06091076 0.51452691 333.00 1.89634443e-02 -6.65937279e-02 6.92411498e-02 -1.29337618 0.64872300 333.25 -8.08452525e-04 -7.57431177e-02 7.57474322e-02 -1.58146953 0.57199547 333.50 -2.93173687e-02 -7.23016189e-02 7.80194348e-02 -1.95602393 0.60273823 333.75 -3.44321964e-02 -4.12502646e-02 5.37323038e-02 -2.26634920 0.49270139 334.00 -2.88885341e-02 -2.86222273e-02 4.06666854e-02 -2.36082501 0.53352154 334.25 -1.72232608e-02 -2.21912660e-02 2.80907992e-02 -2.23081068 0.23399734 334.50 -8.38156280e-03 -2.44459478e-02 2.58428899e-02 -1.90109716 0.18042879 334.75 8.17417647e-03 -3.99757599e-02 4.08029232e-02 -1.36909842 0.31584115 335.00 5.23451321e-03 -5.15290232e-02 5.17942116e-02 -1.46955982 0.50905511 335.25 -8.71206682e-03 -7.06489632e-02 7.11841002e-02 -1.69349176 0.48340126 335.50 -1.73910393e-02 -8.66392385e-02 8.83674482e-02 -1.76889310 0.65208887 335.75 -2.35046685e-02 -8.39536787e-02 8.71819340e-02 -1.84377895 0.59045625 336.00 -2.67479880e-02 -9.73986189e-02 1.01004682e-01 -1.83881284 0.69335902 336.25 -2.17785722e-02 -9.62894890e-02 9.87216891e-02 -1.79323180 0.62671415 336.50 -2.88553505e-02 -1.03157120e-01 1.07116864e-01 -1.84354753 0.69259847 336.75 -6.03169610e-02 -1.20665029e-01 1.34900648e-01 -2.03434081 0.65631157 337.00 -9.35766888e-02 -1.32436196e-01 1.62160237e-01 -2.18592437 0.69069159 337.25 -1.46159664e-01 -1.02884161e-01 1.78739469e-01 -2.52824317 0.74664177 337.50 -1.63365749e-01 -8.66378779e-02 1.84917522e-01 -2.65397590 0.78888191 337.75 -1.87565003e-01 -5.79956216e-02 1.96326571e-01 -2.84171446 0.79362726 338.00 -1.85515574e-01 -3.42089149e-02 1.88643256e-01 -2.95924191 0.81395648 338.25 -1.69159230e-01 1.20389823e-03 1.69163514e-01 3.13447582 0.78307150 338.50 -1.62347472e-01 2.06319128e-02 1.63653224e-01 3.01518536 0.77989963 338.75 -1.64347713e-01 2.32166185e-02 1.65979463e-01 3.00125601 0.76112960 339.00 -1.66945660e-01 3.12547676e-02 1.69846148e-01 2.95651983 0.72072266 339.25 -1.38072388e-01 3.10680211e-02 1.41524578e-01 2.92026626 0.62378566 339.50 -1.16328212e-01 3.80010876e-02 1.22377839e-01 2.82584987 0.63282341 339.75 -1.13632324e-01 5.60526946e-02 1.26705208e-01 2.68333448 0.74775488 340.00 -1.13642222e-01 5.46528494e-02 1.26101105e-01 2.69332499 0.70091121 340.25 -1.09526876e-01 7.23463815e-02 1.31263611e-01 2.55784678 0.68160364 340.50 -1.02855244e-01 7.14041696e-02 1.25210849e-01 2.53475641 0.66162980 340.75 -9.01668947e-02 6.00715931e-02 1.08345121e-01 2.55389470 0.66053146 341.00 -8.98924755e-02 6.78799325e-02 1.12642543e-01 2.49482048 0.60604798 341.25 -7.35997352e-02 8.27608905e-02 1.10753266e-01 2.29767148 0.55470035 341.50 -5.64566091e-02 7.68996980e-02 9.53987016e-02 2.20408190 0.48044670 341.75 -4.96175198e-02 7.99082833e-02 9.40597257e-02 2.12646417 0.50423476 342.00 -3.22672024e-02 7.13685556e-02 7.83239624e-02 1.99541244 0.33261841 342.25 -8.99070042e-03 5.68900914e-02 5.75961387e-02 1.72753634 0.26890079 342.50 -4.03450529e-03 5.04278433e-02 5.05889772e-02 1.65063179 0.15197231 342.75 -1.26701753e-02 4.64621209e-02 4.81587170e-02 1.83702209 0.16172261 343.00 7.78404469e-03 6.98030101e-03 1.04554270e-02 0.73101369 0.00696047 343.25 2.18300945e-02 -2.00182149e-02 2.96189459e-02 -0.74212882 0.07903378 343.50 2.27816117e-02 -2.03315711e-02 3.05348099e-02 -0.72863111 0.07252808 343.75 2.96423024e-02 -1.55568233e-02 3.34765715e-02 -0.48330457 0.11697408 344.00 4.64252269e-02 -4.37268708e-02 6.37757079e-02 -0.75547595 0.26684016 344.25 6.01901283e-02 -6.32983478e-02 8.73471945e-02 -0.81056297 0.54342663 344.50 6.84064607e-02 -9.13208655e-02 1.14100589e-01 -0.92788549 0.54886694 344.75 8.42860825e-02 -1.22853687e-01 1.48987155e-01 -0.96948148 0.62932587 345.00 1.07145297e-01 -2.01943276e-01 2.28607089e-01 -1.08299187 0.67567594 345.25 1.11488963e-01 -2.82901804e-01 3.04077654e-01 -1.19539455 0.81865879 345.50 5.55155711e-02 -3.28170626e-01 3.32833199e-01 -1.40321609 0.76751638 345.75 -9.96738787e-03 -3.90072369e-01 3.90199695e-01 -1.59634343 0.83877918 346.00 -1.20451990e-01 -4.48736965e-01 4.64621939e-01 -1.83303912 0.84337959 346.25 -1.88779694e-01 -4.57818372e-01 4.95212514e-01 -1.96190052 0.89674073 346.50 -3.06787309e-01 -4.43311394e-01 5.39113573e-01 -2.17615710 0.89088308 346.75 -3.57833877e-01 -4.12572552e-01 5.46132946e-01 -2.28526201 0.92180361 347.00 -4.11666364e-01 -4.02725859e-01 5.75896964e-01 -2.36717218 0.92938911 347.25 -4.35633436e-01 -3.87329253e-01 5.82924044e-01 -2.41482270 0.93519947 347.50 -5.08406172e-01 -4.11037967e-01 6.53780579e-01 -2.46170025 0.91546782 347.75 -5.79976587e-01 -4.05115395e-01 7.07454114e-01 -2.53187208 0.92692004 348.00 -6.93732648e-01 -3.92425117e-01 7.97033537e-01 -2.62679689 0.93143463 348.25 -7.62586557e-01 -3.73518695e-01 8.49149264e-01 -2.68613427 0.94141248 348.50 -8.63593946e-01 -3.38020454e-01 9.27390064e-01 -2.76851216 0.91710276 348.75 -9.39231075e-01 -2.46596507e-01 9.71063772e-01 -2.88483616 0.91021093 349.00 -1.08939099e+00 -1.29892386e-01 1.09710745e+00 -3.02291898 0.95082521 349.25 -1.13447529e+00 -8.36065561e-02 1.13755186e+00 -3.06802940 0.94114323 349.50 -1.18505855e+00 1.21590772e-01 1.19128002e+00 3.03934727 0.95061876 349.75 -1.22221453e+00 1.91051725e-01 1.23705664e+00 2.98653145 0.94949029 350.00 -1.22718542e+00 3.80597003e-01 1.28484946e+00 2.84086096 0.96778485 350.25 -1.23873599e+00 4.83074038e-01 1.32959670e+00 2.76975970 0.96560412 350.50 -1.20343102e+00 7.29662586e-01 1.40735700e+00 2.59654009 0.96192391 350.75 -1.14575630e+00 8.53593086e-01 1.42876823e+00 2.50129663 0.95204905 351.00 -1.00958430e+00 9.97525563e-01 1.41926661e+00 2.36220243 0.95910970 351.25 -9.48011789e-01 1.10536478e+00 1.45621346e+00 2.27971263 0.95806713 351.50 -7.92302678e-01 1.25178489e+00 1.48145501e+00 2.13508377 0.95989888 351.75 -6.61242250e-01 1.33893299e+00 1.49331272e+00 2.02951796 0.95830511 352.00 -4.89964350e-01 1.46673031e+00 1.54640320e+00 1.89319364 0.96013639 352.25 -3.10167910e-01 1.48571029e+00 1.51774148e+00 1.77660771 0.95540849 352.50 -1.49283886e-01 1.34723777e+00 1.35548342e+00 1.68115351 0.95115093 352.75 -8.84387074e-02 1.15049207e+00 1.15388622e+00 1.64751578 0.94582458 353.00 -6.50063851e-02 1.06264542e+00 1.06463191e+00 1.63189430 0.95372254 353.25 -1.32685348e-01 1.02610503e+00 1.03464822e+00 1.69939246 0.93799882 353.50 -2.27511588e-01 1.02103857e+00 1.04607901e+00 1.79003837 0.94625409 353.75 -3.68209821e-01 1.10134488e+00 1.16126612e+00 1.89344132 0.93118549 354.00 -4.84910263e-01 1.26498276e+00 1.35473959e+00 1.93685298 0.93861297 354.25 -4.76549838e-01 1.65578870e+00 1.72300202e+00 1.85103095 0.93317409 354.50 -4.35096051e-01 2.08655392e+00 2.13143516e+00 1.77637421 0.94741980 354.75 -1.02519032e-01 2.48934489e+00 2.49145502e+00 1.61195620 0.89527704 355.00 4.88163834e-01 3.01246350e+00 3.05176019e+00 1.41014478 0.91763050 355.25 1.86908242e+00 3.09224340e+00 3.61323101e+00 1.02711690 0.90165661 355.50 3.03458948e+00 3.02285935e+00 4.28327118e+00 0.78346169 0.92712159 355.75 3.77121247e+00 1.71291940e+00 4.14199666e+00 0.42634878 0.81717642 356.00 4.19699684e+00 9.26561919e-02 4.19801950e+00 0.02207320 0.83597062 356.25 2.92234349e+00 -1.83088780e+00 3.44851295e+00 -0.55968697 0.63448173 356.50 1.59393166e+00 -2.75093766e+00 3.17935153e+00 -1.04565117 0.72306628 356.75 8.27480598e-03 -1.95785847e+00 1.95787595e+00 -1.56656989 0.70754446 357.00 -3.87598997e-01 -1.53988444e+00 1.58791596e+00 -1.81738051 0.78013862 357.25 -4.61767344e-01 -6.65641412e-01 8.10128119e-01 -2.17729364 0.71694181 357.50 -3.88322490e-01 -4.34948706e-01 5.83073523e-01 -2.29961962 0.81847706 357.75 -2.88556013e-01 -2.82898890e-01 4.04099437e-01 -2.36609368 0.81974506 358.00 -2.33379168e-01 -2.28539046e-01 3.26643432e-01 -2.36667242 0.78358800 358.25 -1.94180743e-01 -9.83248619e-02 2.17655553e-01 -2.67287205 0.41937018 358.50 -1.29956559e-01 4.92186733e-02 1.38964690e-01 2.77955435 0.24598009 358.75 -7.33444088e-03 9.84615851e-02 9.87343798e-02 1.64514939 0.31531016 359.00 2.72303577e-02 9.83532287e-02 1.02053172e-01 1.30069904 0.48882186 359.25 1.06714936e-01 8.53036863e-02 1.36619166e-01 0.67435078 0.73101857 359.50 1.19531097e-01 6.30753889e-02 1.35152461e-01 0.48555360 0.77079797 359.75 1.17554202e-01 3.58215873e-02 1.22890913e-01 0.29578509 0.81188942 360.00 1.12202563e-01 2.40632508e-02 1.14753889e-01 0.21126243 0.82191765 360.25 1.11931016e-01 1.95844539e-02 1.13631436e-01 0.17321555 0.84798304 360.50 1.04118158e-01 2.13192719e-02 1.06278418e-01 0.20196861 0.82956208 360.75 8.93941688e-02 2.27806310e-02 9.22511494e-02 0.24952266 0.83749399 361.00 8.58346641e-02 2.16981623e-02 8.85347378e-02 0.24760301 0.81285268 361.25 6.74386042e-02 1.40349865e-03 6.74532071e-02 0.02080850 0.65898043 361.50 4.59910777e-02 2.19320379e-04 4.59916006e-02 0.00476872 0.43457966 361.75 1.82222539e-02 1.68044902e-02 2.47879291e-02 0.74494364 0.13071689 362.00 7.22470980e-03 3.94623214e-02 4.01182159e-02 1.38972293 0.22066846 362.25 -1.52095288e-02 4.96289358e-02 5.19072349e-02 1.86817365 0.46762750 362.50 -2.92468655e-02 7.15802645e-02 7.73247270e-02 1.95868450 0.64398470 362.75 -4.85683243e-02 1.12335540e-01 1.22385275e-01 1.97887638 0.86213498 363.00 -3.89454464e-02 1.35318514e-01 1.40811392e-01 1.85102853 0.84199239 363.25 -1.36312513e-02 1.67056332e-01 1.67611542e-01 1.65221269 0.90947248 363.50 -1.67413909e-03 1.70040613e-01 1.70048855e-01 1.58064153 0.92065709 363.75 6.25893507e-03 1.62325504e-01 1.62446125e-01 1.53225749 0.94534512 364.00 6.39233324e-03 1.62695440e-01 1.62820970e-01 1.53152635 0.93475246 364.25 5.45873051e-04 1.61576846e-01 1.61577768e-01 1.56741793 0.94780986 364.50 -7.55267269e-03 1.63027116e-01 1.63201971e-01 1.61709093 0.92233289 364.75 -2.78519456e-02 1.66340174e-01 1.68655816e-01 1.73669703 0.92376820 365.00 -3.21567140e-02 1.93543469e-01 1.96196658e-01 1.73543958 0.89280727 365.25 -2.68337622e-02 2.25150910e-01 2.26744313e-01 1.68941803 0.90504399 365.50 -1.52248173e-02 2.32694528e-01 2.33192063e-01 1.63613155 0.87315062 365.75 -1.39430146e-03 2.42616074e-01 2.42620080e-01 1.57654321 0.91158409 366.00 1.12462712e-02 2.46926184e-01 2.47182157e-01 1.52528271 0.93418250 366.25 1.27581348e-02 2.52053351e-01 2.52376032e-01 1.52022269 0.96306635 366.50 1.79149123e-02 2.53764744e-01 2.54396324e-01 1.50031672 0.95437548 366.75 2.29524675e-02 2.54574213e-01 2.55606818e-01 1.48087922 0.96458976 367.00 2.86585509e-02 2.54095840e-01 2.55706880e-01 1.45848457 0.96181619 367.25 2.74298730e-02 2.55125152e-01 2.56595481e-01 1.46369239 0.97078538 367.50 1.20754899e-02 2.41356310e-01 2.41658201e-01 1.52080621 0.94732903 367.75 -2.24539941e-03 2.49647114e-01 2.49657212e-01 1.57979038 0.94704396 368.00 -1.73774377e-02 2.89336038e-01 2.89857410e-01 1.63078397 0.96628185 368.25 -1.69090498e-02 3.11568410e-01 3.12026906e-01 1.62501388 0.97168858 368.50 4.69333969e-03 3.42139797e-01 3.42171986e-01 1.55707958 0.96518705 368.75 1.35577118e-02 3.52181955e-01 3.52442820e-01 1.53231900 0.96618033 369.00 5.30680133e-02 3.47015798e-01 3.51050108e-01 1.41904523 0.94403851 369.25 5.52978326e-02 3.35934164e-01 3.40455008e-01 1.40765024 0.93986346 369.50 5.15715119e-02 3.03940074e-01 3.08284268e-01 1.40272052 0.94361403 369.75 3.15466414e-02 3.08005028e-01 3.09616356e-01 1.46872975 0.94861402 370.00 3.82018255e-02 3.48633325e-01 3.50720080e-01 1.46165581 0.93701686 370.25 5.25040398e-02 3.55658852e-01 3.59513411e-01 1.42423019 0.94316855 370.50 3.87983757e-02 3.24401204e-01 3.26713109e-01 1.45176177 0.95385756 370.75 1.90930441e-02 3.27819384e-01 3.28374927e-01 1.51261948 0.95123339 371.00 -2.37426673e-02 3.61863404e-01 3.62641473e-01 1.63631465 0.96668640 371.25 -3.68614704e-02 3.90106684e-01 3.91844347e-01 1.66500735 0.95818727 371.50 -8.16700627e-02 4.69216859e-01 4.76271414e-01 1.74312601 0.96442604 371.75 -9.79062568e-02 5.31847651e-01 5.40784207e-01 1.75284520 0.96322460 372.00 -7.69375378e-02 6.37749598e-01 6.42373672e-01 1.69085523 0.97471667 372.25 -4.42068241e-02 7.13686770e-01 7.15054577e-01 1.63265878 0.96136794 372.50 6.43448248e-02 8.52524353e-01 8.54949138e-01 1.49546351 0.96834478 372.75 2.04919593e-01 9.26031535e-01 9.48433679e-01 1.35301789 0.95335313 373.00 4.67027713e-01 9.54375873e-01 1.06251974e+00 1.11570168 0.95270055 373.25 5.80827874e-01 7.72186898e-01 9.66247186e-01 0.92589789 0.90539683 373.50 7.56345101e-01 4.80494078e-01 8.96064992e-01 0.56596052 0.95261109 373.75 6.95798222e-01 3.45171103e-01 7.76709892e-01 0.46050614 0.95162662 374.00 6.27231509e-01 2.60674873e-01 6.79242781e-01 0.39387844 0.98300673 374.25 5.56085940e-01 2.31605796e-01 6.02389257e-01 0.39464297 0.97241579 374.50 4.74945131e-01 1.84944544e-01 5.09683589e-01 0.37133684 0.98208313 374.75 4.11193231e-01 1.70485782e-01 4.45135120e-01 0.39303940 0.97026940 375.00 3.48221765e-01 1.61754791e-01 3.83957042e-01 0.43486014 0.97408160 375.25 2.86918947e-01 1.81770834e-01 3.39651465e-01 0.56470744 0.96270376 375.50 2.45739595e-01 2.18953342e-01 3.29132974e-01 0.72781897 0.95955292 375.75 2.35737194e-01 2.91098711e-01 3.74580411e-01 0.89009695 0.93153760 376.00 2.47337099e-01 3.46236703e-01 4.25506163e-01 0.95049871 0.97051882 376.25 2.76994765e-01 3.73730350e-01 4.65188644e-01 0.93297552 0.97942378 376.50 2.87530986e-01 3.85908100e-01 4.81247472e-01 0.93045383 0.98589528 376.75 3.20257281e-01 4.22329934e-01 5.30025753e-01 0.92199759 0.97970340 377.00 3.61426594e-01 4.46272776e-01 5.74272212e-01 0.89006105 0.99020659 377.25 4.11804785e-01 4.30209274e-01 5.95536061e-01 0.80725238 0.98359960 377.50 4.57018577e-01 3.93938449e-01 6.03368446e-01 0.71140504 0.97983834 377.75 4.67366616e-01 3.13637683e-01 5.62850024e-01 0.59104778 0.97536537 378.00 4.51892212e-01 2.76459304e-01 5.29751185e-01 0.54903737 0.97392996 378.25 3.66165935e-01 2.33961969e-01 4.34529280e-01 0.56856842 0.95000759 378.50 3.16238367e-01 2.42521424e-01 3.98526468e-01 0.65422612 0.95582123 378.75 2.85770355e-01 2.89845771e-01 4.07032268e-01 0.79247814 0.95586937 379.00 2.64099377e-01 3.20972880e-01 4.15658599e-01 0.88230136 0.96334708 379.25 2.56942862e-01 3.51707913e-01 4.35566402e-01 0.93985496 0.94934131 379.50 2.55541333e-01 3.80480932e-01 4.58330790e-01 0.97936738 0.95748286 379.75 2.64026696e-01 4.32792356e-01 5.06970729e-01 1.02301698 0.96871778 380.00 2.67157184e-01 4.34859727e-01 5.10368439e-01 1.01989027 0.96848537 380.25 2.67332334e-01 4.60898283e-01 5.32816858e-01 1.04519414 0.96154434 380.50 2.47559395e-01 4.81488435e-01 5.41402593e-01 1.09588943 0.96284263 380.75 2.06891615e-01 5.41222898e-01 5.79418990e-01 1.20566992 0.95279634 381.00 1.97757296e-01 6.09400049e-01 6.40684297e-01 1.25700636 0.94610517 381.25 1.92847908e-01 7.45792690e-01 7.70322693e-01 1.31775776 0.94236830 381.50 2.30885550e-01 8.63626302e-01 8.93956669e-01 1.30956142 0.92945086 381.75 3.34227823e-01 1.10231190e+00 1.15186795e+00 1.27640065 0.95360081 382.00 4.24697256e-01 1.17840916e+00 1.25260365e+00 1.22488774 0.93330048 382.25 8.20217691e-01 1.30626980e+00 1.54243245e+00 1.01010836 0.95199708 382.50 1.02804605e+00 1.30138724e+00 1.65845936e+00 0.90220635 0.93951855 382.75 1.47675825e+00 1.12621657e+00 1.85719646e+00 0.65153390 0.95218284 383.00 1.70544003e+00 8.64961657e-01 1.91224589e+00 0.46937350 0.94552180 383.25 1.83274581e+00 3.96384403e-01 1.87512075e+00 0.21299831 0.96482838 383.50 1.78567383e+00 1.32711857e-01 1.79059864e+00 0.07418394 0.96863828 383.75 1.58142553e+00 -1.49171471e-01 1.58844542e+00 -0.09404894 0.97431371 384.00 1.37014687e+00 -2.50090627e-01 1.39278418e+00 -0.18054084 0.96299005 384.25 1.21180366e+00 -3.04924332e-01 1.24957872e+00 -0.24651078 0.98122253 384.50 1.08714905e+00 -3.07478131e-01 1.12979461e+00 -0.27563083 0.97409284 384.75 9.89660985e-01 -2.70030266e-01 1.02583878e+00 -0.26636747 0.98416994 385.00 9.34332007e-01 -2.18232695e-01 9.59479968e-01 -0.22945715 0.98361202 385.25 8.91645437e-01 -1.79282230e-01 9.09490903e-01 -0.19842320 0.98749642 385.50 8.60285387e-01 -1.72109530e-01 8.77332683e-01 -0.19745418 0.98873690 385.75 8.48941981e-01 -1.62206400e-01 8.64299372e-01 -0.18879339 0.99214624 386.00 8.19946083e-01 -1.51302417e-01 8.33788943e-01 -0.18247465 0.98609595 386.25 7.90714144e-01 -1.32110908e-01 8.01674590e-01 -0.16554883 0.99058612 386.50 7.97049451e-01 -8.70490991e-02 8.01788858e-01 -0.10878303 0.98650682 386.75 8.30663622e-01 -4.26691783e-02 8.31758807e-01 -0.05132247 0.98572209 387.00 8.82104242e-01 -7.84273936e-02 8.85583847e-01 -0.08867627 0.98715410 387.25 9.00457877e-01 -1.02145537e-01 9.06232917e-01 -0.11295448 0.99050117 387.50 8.96428204e-01 -1.34114343e-01 9.06405087e-01 -0.14850820 0.98691354 387.75 9.01711427e-01 -1.64262392e-01 9.16550943e-01 -0.18019149 0.99093385 388.00 9.11093632e-01 -2.02764149e-01 9.33383580e-01 -0.21898155 0.98716892 388.25 9.24095881e-01 -2.29130294e-01 9.52078720e-01 -0.24304906 0.99096113 388.50 9.29307948e-01 -2.59551200e-01 9.64873094e-01 -0.27235497 0.98922892 388.75 9.39956606e-01 -2.96382370e-01 9.85576446e-01 -0.30544732 0.98684690 389.00 9.29281428e-01 -3.66852436e-01 9.99071910e-01 -0.37598965 0.98660044 389.25 9.15325213e-01 -4.04597627e-01 1.00075945e+00 -0.41620307 0.98968439 389.50 8.83826994e-01 -4.98281541e-01 1.01461059e+00 -0.51335918 0.98869649 389.75 8.52389267e-01 -5.41851394e-01 1.01003485e+00 -0.56624631 0.98793990 390.00 7.63583486e-01 -6.04435377e-01 9.73859263e-01 -0.66958403 0.97740973 390.25 6.91246089e-01 -6.08471947e-01 9.20901333e-01 -0.72179783 0.98043809 390.50 6.30529914e-01 -5.96659623e-01 8.68084488e-01 -0.75780528 0.98016827 390.75 6.02867021e-01 -6.11301437e-01 8.58567465e-01 -0.79234471 0.97804204 391.00 5.02341809e-01 -5.86162087e-01 7.71967153e-01 -0.86225153 0.97850161 391.25 4.62120048e-01 -5.61758809e-01 7.27411780e-01 -0.88240769 0.97432280 391.50 4.08500369e-01 -5.12585078e-01 6.55451000e-01 -0.89792305 0.96997665 391.75 4.04100190e-01 -4.92223985e-01 6.36852742e-01 -0.88340008 0.96700441 392.00 3.91301023e-01 -4.26019406e-01 5.78453995e-01 -0.82785094 0.97282454 392.25 4.02094205e-01 -4.11364782e-01 5.75239718e-01 -0.79679416 0.96064399 392.50 4.48417010e-01 -4.50445895e-01 6.35593674e-01 -0.78765533 0.95104662 392.75 4.25590208e-01 -4.71985194e-01 6.35528952e-01 -0.83704144 0.93527348 393.00 3.51345518e-01 -4.89621842e-01 6.02638549e-01 -0.94836528 0.92134206 393.25 2.86428919e-01 -4.83479045e-01 5.61955081e-01 -1.03595941 0.90206146 393.50 1.48825043e-01 -4.68256756e-01 4.91338257e-01 -1.26306500 0.87007731 393.75 9.90322592e-02 -3.97458316e-01 4.09610183e-01 -1.32660475 0.82704995 394.00 5.76247590e-02 -2.75795760e-01 2.81751511e-01 -1.36481960 0.68010483 394.25 5.86742660e-02 -1.75075453e-01 1.84645834e-01 -1.24742333 0.44044008 394.50 1.16563799e-01 -8.70274077e-02 1.45467828e-01 -0.64132638 0.33234646 394.75 2.11063777e-01 -3.05444125e-03 2.11085878e-01 -0.01447064 0.47633200 395.00 3.34883078e-01 2.18924758e-02 3.35597909e-01 0.06528060 0.61835919 395.25 4.47870777e-01 -2.09984412e-02 4.48362764e-01 -0.04685074 0.63274901 395.50 6.65839296e-01 -6.76785986e-02 6.69270020e-01 -0.10129615 0.77729232 395.75 6.81708031e-01 -2.64115285e-01 7.31083253e-01 -0.36962488 0.75128331 396.00 5.57648939e-01 -5.01538664e-01 7.50008914e-01 -0.73247281 0.80955799 396.25 3.13978241e-01 -4.43246509e-01 5.43184871e-01 -0.95448142 0.83831315 396.50 2.20232047e-01 -3.75687010e-01 4.35480061e-01 -1.04057713 0.88033029 396.75 1.83209626e-01 -2.82785348e-01 3.36947059e-01 -0.99591623 0.80507136 397.00 1.82446066e-01 -2.24457867e-01 2.89254043e-01 -0.88828109 0.75879487 397.25 2.66999157e-01 -1.63358288e-01 3.13008754e-01 -0.54907318 0.81874609 397.50 3.39708888e-01 -1.75521102e-01 3.82373882e-01 -0.47690312 0.91084792 397.75 3.55449956e-01 -2.63697928e-01 4.42584758e-01 -0.63827806 0.93838432 398.00 3.50650366e-01 -3.07106438e-01 4.66122348e-01 -0.71929397 0.96691708 398.25 2.82141636e-01 -3.06426223e-01 4.16534432e-01 -0.82663524 0.96020263 398.50 2.50527197e-01 -2.89204788e-01 3.82626823e-01 -0.85693661 0.96735387 398.75 2.29522778e-01 -2.45978632e-01 3.36431558e-01 -0.81999173 0.96185858 399.00 2.21785821e-01 -2.28607355e-01 3.18512595e-01 -0.80054274 0.96672095 399.25 2.24200106e-01 -1.95325409e-01 2.97351144e-01 -0.71667950 0.96978902 399.50 2.26164119e-01 -1.83126532e-01 2.91007793e-01 -0.68063151 0.97234636 399.75 2.33807820e-01 -1.73029410e-01 2.90869857e-01 -0.63710245 0.97218934 400.00 2.29251216e-01 -1.66617742e-01 2.83403585e-01 -0.62848120 0.97888173 400.25 2.16669340e-01 -1.51233001e-01 2.64229111e-01 -0.60937560 0.96255873 400.50 2.03204234e-01 -1.32015963e-01 2.42322461e-01 -0.57614413 0.93912835 400.75 1.83053900e-01 -9.25808319e-02 2.05133958e-01 -0.46824277 0.92709296 401.00 1.81383436e-01 -6.37869651e-02 1.92272535e-01 -0.33816107 0.91159469 401.25 1.95466752e-01 1.18599838e-02 1.95826225e-01 0.06060090 0.85056163 401.50 2.15869184e-01 8.08271899e-02 2.30504965e-01 0.35826797 0.82904337 401.75 2.98832482e-01 1.60496287e-01 3.39204821e-01 0.49286802 0.89438659 402.00 3.80029875e-01 2.00282377e-01 4.29576229e-01 0.48502723 0.90007233 402.25 5.22442259e-01 1.85227200e-01 5.54305899e-01 0.34071451 0.92983657 402.50 6.04833865e-01 1.49914014e-01 6.23135793e-01 0.24296337 0.92223946 402.75 7.40341713e-01 -3.89471210e-02 7.41365450e-01 -0.05255850 0.95984906 403.00 7.39300021e-01 -1.25421156e-01 7.49863312e-01 -0.16804853 0.94427057 403.25 7.06423258e-01 -2.91853226e-01 7.64337704e-01 -0.39178423 0.95789498 403.50 6.69783556e-01 -3.64892238e-01 7.62729543e-01 -0.49883540 0.93749856 403.75 5.90191271e-01 -4.89546274e-01 7.66799381e-01 -0.69245426 0.96440747 404.00 5.17267791e-01 -5.33173378e-01 7.42859218e-01 -0.80053882 0.94781143 404.25 3.87121676e-01 -5.90214460e-01 7.05844389e-01 -0.99028464 0.94546538 404.50 3.05557455e-01 -5.54227975e-01 6.32877560e-01 -1.06693957 0.92098337 404.75 1.58191445e-01 -4.57134416e-01 4.83731752e-01 -1.23764461 0.88664202 405.00 1.30539718e-01 -3.40422361e-01 3.64592926e-01 -1.20462590 0.84038428 405.25 1.38280407e-01 -2.43106022e-01 2.79681978e-01 -1.05362871 0.82115650 405.50 1.84431161e-01 -2.08602886e-01 2.78442126e-01 -0.84682113 0.83771570 405.75 2.53456725e-01 -2.18770654e-01 3.34814740e-01 -0.71207778 0.88278375 406.00 2.86096890e-01 -2.71092681e-01 3.94135347e-01 -0.75847630 0.89796800 406.25 2.74190711e-01 -3.31212297e-01 4.29979222e-01 -0.87930893 0.93920306 406.50 2.30294163e-01 -3.56017464e-01 4.24009241e-01 -0.99663026 0.92065592 406.75 1.40878567e-01 -3.65588212e-01 3.91792690e-01 -1.20298473 0.90028987 407.00 6.28882937e-02 -3.26977119e-01 3.32969929e-01 -1.38078421 0.86291649 407.25 1.93845176e-02 -2.87708957e-01 2.88361238e-01 -1.50352256 0.89176792 407.50 1.52330524e-02 -2.41755053e-01 2.42234497e-01 -1.50786924 0.85749532 407.75 1.53983112e-02 -2.11890844e-01 2.12449612e-01 -1.49825289 0.84629672 408.00 -2.74956374e-03 -1.67111290e-01 1.67133908e-01 -1.58724833 0.73558452 408.25 -1.35131178e-02 -1.31193418e-01 1.31887517e-01 -1.67343586 0.72165492 408.50 2.46584721e-03 -1.16127355e-01 1.16153532e-01 -1.54956553 0.58710575 408.75 1.41189776e-02 -1.07964189e-01 1.08883477e-01 -1.44075964 0.56658745 409.00 1.07349325e-03 -1.16277778e-01 1.16282733e-01 -1.56156444 0.53890478 409.25 -3.82809359e-04 -1.13756996e-01 1.13757640e-01 -1.57416146 0.53114089 409.50 -5.51737700e-02 -1.20657272e-01 1.32673744e-01 -1.99968513 0.49146956 409.75 -8.20719081e-02 -1.15778113e-01 1.41916769e-01 -2.18745213 0.54667276 410.00 -1.05603604e-01 -9.85032309e-02 1.44412630e-01 -2.39096800 0.52806785 410.25 -1.25069183e-01 -6.88630426e-02 1.42774015e-01 -2.63828921 0.52982818 410.50 -1.62344433e-01 -9.09720402e-05 1.62344458e-01 -3.14103229 0.54731655 410.75 -1.95920169e-01 2.74815689e-02 1.97838190e-01 3.00223268 0.66939598 411.00 -2.45709285e-01 5.99363419e-02 2.52913855e-01 2.90233321 0.72267408 411.25 -2.61420107e-01 9.08667676e-02 2.76762067e-01 2.80706728 0.71685528 411.50 -3.22133308e-01 1.69722550e-01 3.64109341e-01 2.65668041 0.73341721 411.75 -3.37473081e-01 2.32088181e-01 4.09576616e-01 2.53915353 0.71495237 412.00 -3.33111556e-01 3.21744700e-01 4.63123051e-01 2.37355053 0.78548488 412.25 -3.33081198e-01 3.86340543e-01 5.10100088e-01 2.28229852 0.79843233 412.50 -3.50359219e-01 5.05448437e-01 6.15003825e-01 2.17692037 0.74634580 412.75 -3.05024268e-01 6.10800187e-01 6.82727378e-01 2.03395157 0.76590050 413.00 -1.86602463e-01 8.81539380e-01 9.01072782e-01 1.77939507 0.73752710 413.25 4.30430250e-02 9.52623165e-01 9.53595090e-01 1.52564335 0.74552482 413.50 3.72974219e-01 8.12611709e-01 8.94118313e-01 1.14049805 0.79224379 413.75 4.50935211e-01 5.49408105e-01 7.10768479e-01 0.88352113 0.65421223 414.00 3.38191746e-01 2.37209061e-01 4.13088121e-01 0.61166766 0.65079961 414.25 2.37441044e-01 1.86076181e-01 3.01666363e-01 0.66470599 0.46444579 414.50 3.61633240e-02 1.34411775e-01 1.39191635e-01 1.30797129 0.16633422 414.75 -1.10328319e-01 1.89637839e-01 2.19396554e-01 2.09771424 0.25003379 415.00 -2.34804380e-01 2.25723559e-01 3.25705729e-01 2.37591022 0.42701968 415.25 -2.74351073e-01 2.61200390e-01 3.78806223e-01 2.38074496 0.35909459 415.50 -2.81215622e-01 4.58398624e-01 5.37783901e-01 2.12106429 0.59888279 415.75 -3.16600664e-01 4.99566301e-01 5.91441012e-01 2.13566379 0.57367911 416.00 -3.56095360e-01 5.29353776e-01 6.37980662e-01 2.16296303 0.64888816 416.25 -3.00657859e-01 4.76072718e-01 5.63063390e-01 2.13408309 0.52980818 416.50 -3.18781933e-01 4.35517254e-01 5.39719556e-01 2.20265260 0.55623448 416.75 -4.53070054e-01 3.99691738e-01 6.04173782e-01 2.41870757 0.56399753 417.00 -6.55567646e-01 4.10425911e-01 7.73445775e-01 2.58223011 0.69402119 417.25 -8.33503948e-01 3.97419202e-01 9.23401783e-01 2.69667229 0.73128630 417.50 -1.06180174e+00 4.55320473e-01 1.15530934e+00 2.73649196 0.80026494 417.75 -1.34448128e+00 5.22657120e-01 1.44249796e+00 2.77082846 0.73736429 418.00 -1.64766244e+00 5.92113554e-01 1.75082552e+00 2.79659861 0.81036885 418.25 -2.01299799e+00 4.43278297e-01 2.06122695e+00 2.92484394 0.75687154 418.50 -2.35868021e+00 5.06946422e-01 2.41254368e+00 2.92988531 0.81045573 418.75 -3.10730976e+00 4.32730362e-01 3.13729652e+00 3.00322054 0.76963349 419.00 -3.62150923e+00 5.11686899e-01 3.65747900e+00 3.00123069 0.77763468 419.25 -3.75748192e+00 5.78435950e-01 3.80174415e+00 2.98884926 0.60590222 419.50 -3.81346043e+00 7.23304508e-01 3.88144946e+00 2.95414784 0.45432761 419.75 -2.49762195e+00 -3.43106234e-01 2.52107859e+00 -3.00507397 0.12768950 420.00 -8.72634040e-01 -2.24541422e+00 2.40901955e+00 -1.94146222 0.08225848 420.25 1.74037310e+00 -1.81123604e-01 1.74977264e+00 -0.10369840 0.03768241 420.50 3.28782429e+00 -4.56732194e-01 3.31939646e+00 -0.13803286 0.11235578 420.75 4.05806376e+00 -2.59522896e+00 4.81695909e+00 -0.56897540 0.26309145 421.00 4.69425952e+00 -2.53418049e+00 5.33461743e+00 -0.49501456 0.36260595 421.25 7.24017946e+00 -1.22053871e+00 7.34233705e+00 -0.16700828 0.63789919 421.50 7.69210823e+00 -9.29443485e-01 7.74805745e+00 -0.12024784 0.70992253 421.75 6.33851138e+00 -1.04895052e+00 6.42471974e+00 -0.16400210 0.77721173 422.00 5.80497490e+00 -1.00764082e+00 5.89178017e+00 -0.17186975 0.72215026 422.25 6.14363853e+00 -4.48945026e-02 6.14380256e+00 -0.00730735 0.79366285 422.50 6.41517495e+00 4.46013327e-01 6.43066074e+00 0.06941304 0.82279436 422.75 6.14440159e+00 1.78568210e+00 6.39861950e+00 0.28282865 0.67641016 423.00 5.89406264e+00 1.84553601e+00 6.17624300e+00 0.30344762 0.51472799 423.25 7.29240711e+00 -1.25587541e+00 7.39975840e+00 -0.17054395 0.39453054 423.50 6.02858146e+00 -4.86187358e+00 7.74477948e+00 -0.67867398 0.40434973 423.75 3.41979000e+00 -7.91349667e+00 8.62081163e+00 -1.16288812 0.62702059 424.00 2.78305880e+00 -6.96627179e+00 7.50162376e+00 -1.19071695 0.68799083 424.25 2.31512321e+00 -6.39736623e+00 6.80338814e+00 -1.22357131 0.79610049 424.50 1.72035034e+00 -5.90208653e+00 6.14770125e+00 -1.28717267 0.81838719 424.75 1.77019767e+00 -5.49536894e+00 5.77344607e+00 -1.25916664 0.86542619 425.00 1.64407004e+00 -4.67894496e+00 4.95938426e+00 -1.23289599 0.86262141 425.25 1.49175761e+00 -4.37891885e+00 4.62604270e+00 -1.24245914 0.91031789 425.50 1.74248027e+00 -4.02692824e+00 4.38775438e+00 -1.16241589 0.91963723 425.75 1.85371257e+00 -4.23323936e+00 4.62131645e+00 -1.15805475 0.94669587 426.00 1.78263137e+00 -4.04510199e+00 4.42047788e+00 -1.15571247 0.95793168 426.25 1.63743965e+00 -4.16547089e+00 4.47575204e+00 -1.19625379 0.92465701 426.50 1.43983548e+00 -4.31232106e+00 4.54634350e+00 -1.24854598 0.90962075 426.75 1.15590134e+00 -4.16824905e+00 4.32555292e+00 -1.30028286 0.92564700 427.00 7.06752055e-01 -4.04671224e+00 4.10796524e+00 -1.39789178 0.90629958 427.25 4.00072571e-01 -3.88775920e+00 3.90828986e+00 -1.46825158 0.91063670 427.50 2.12398882e-01 -3.67382250e+00 3.67995721e+00 -1.51304647 0.79605964 427.75 -1.89563304e-01 -3.55369800e+00 3.55875030e+00 -1.62408837 0.74720540 428.00 -3.27958708e-01 -2.70086439e+00 2.72070310e+00 -1.69163207 0.73772036 428.25 -5.34014586e-01 -2.08553140e+00 2.15281508e+00 -1.82146737 0.53583969 428.50 -9.43090471e-01 -1.52391560e+00 1.79213236e+00 -2.12496820 0.59182566 428.75 -7.91938166e-01 -1.03201584e+00 1.30085463e+00 -2.22532197 0.47210146 429.00 4.46772457e-02 -5.09082875e-01 5.11039558e-01 -1.48326034 0.12804466 429.25 5.91778585e-01 -4.01025467e-01 7.14858950e-01 -0.59557572 0.41089325 429.50 9.94232674e-01 -5.95939296e-01 1.15915584e+00 -0.53997542 0.71512129 429.75 1.16095982e+00 -7.95476229e-01 1.40734151e+00 -0.60071599 0.86145092 430.00 1.24474522e+00 -1.02611356e+00 1.61316450e+00 -0.68941691 0.89272316 430.25 1.17803460e+00 -1.12585556e+00 1.62951412e+00 -0.76275380 0.89555271 430.50 1.05938190e+00 -1.05064966e+00 1.49203040e+00 -0.78125974 0.87675635 430.75 1.07866033e+00 -9.33311597e-01 1.42638657e+00 -0.71328152 0.86116364 431.00 1.29155160e+00 -7.63896077e-01 1.50054749e+00 -0.53411354 0.89895173 431.25 1.48350932e+00 -7.62122462e-01 1.66782210e+00 -0.47457076 0.90692513 431.50 1.93255793e+00 -9.92295691e-01 2.17242512e+00 -0.47435938 0.89467752 431.75 2.14695120e+00 -1.41570571e+00 2.57169635e+00 -0.58295693 0.92906805 432.00 2.09943821e+00 -2.22983753e+00 3.06264857e+00 -0.81550941 0.95546936 432.25 1.83974250e+00 -2.45747746e+00 3.06982865e+00 -0.92817230 0.94480123 432.50 1.16872354e+00 -2.48303927e+00 2.74433940e+00 -1.13087644 0.94115791 432.75 8.56202950e-01 -2.38841460e+00 2.53724414e+00 -1.22658549 0.92616844 433.00 4.76609404e-01 -2.03670938e+00 2.09173173e+00 -1.34092321 0.89486474 433.25 4.25557637e-01 -1.78999972e+00 1.83989084e+00 -1.33738771 0.84153406 433.50 4.26930668e-01 -1.58078633e+00 1.63742335e+00 -1.30701471 0.80636191 433.75 3.74323270e-01 -1.58046686e+00 1.62419007e+00 -1.33823808 0.81930347 434.00 5.43451707e-01 -1.21261402e+00 1.32882373e+00 -1.14946906 0.80588924 434.25 6.66171861e-01 -1.07848759e+00 1.26764366e+00 -1.01747034 0.83119396 434.50 7.16884787e-01 -9.97353739e-01 1.22826637e+00 -0.94757268 0.71501366 434.75 7.67948504e-01 -9.60250318e-01 1.22956317e+00 -0.89621527 0.75379979 435.00 7.95486308e-01 -9.56437399e-01 1.24401405e+00 -0.87701205 0.76673358 435.25 7.94056194e-01 -1.14593368e+00 1.39416256e+00 -0.96482853 0.78923466 435.50 7.28377296e-01 -1.29860446e+00 1.48892815e+00 -1.05962895 0.79341470 435.75 6.89102066e-01 -1.36407038e+00 1.52825052e+00 -1.10301273 0.81838472 436.00 5.92889710e-01 -1.49866368e+00 1.61167957e+00 -1.19407821 0.79289884 436.25 2.78073330e-01 -1.52907535e+00 1.55415450e+00 -1.39090508 0.76027134 436.50 -2.93987012e-02 -1.87655155e+00 1.87678182e+00 -1.58646139 0.78410309 436.75 -1.65190826e-01 -2.01093097e+00 2.01770448e+00 -1.65275874 0.65953229 437.00 -5.79356828e-01 -2.36427301e+00 2.43422292e+00 -1.81110747 0.58706632 437.25 2.07346580e-01 -2.57436795e+00 2.58270458e+00 -1.49042710 0.55529549 437.50 1.12167393e+00 -3.21290960e+00 3.40307809e+00 -1.23491042 0.71315330 437.75 1.68268435e+00 -2.98540099e+00 3.42695867e+00 -1.05754309 0.73134835 438.00 2.24918884e+00 -2.69643077e+00 3.51135150e+00 -0.87558478 0.78753589 438.25 2.37979888e+00 -2.20859807e+00 3.24674424e+00 -0.74810378 0.81971762 438.50 2.57334245e+00 -1.99364551e+00 3.25525940e+00 -0.65914134 0.85771098 438.75 2.78731566e+00 -1.88186382e+00 3.36311463e+00 -0.59385459 0.82726659 439.00 3.08274672e+00 -1.85102260e+00 3.59577697e+00 -0.54074730 0.85596510 439.25 3.41263127e+00 -1.88538869e+00 3.89881299e+00 -0.50474035 0.82561064 439.50 3.93585629e+00 -2.18748349e+00 4.50289337e+00 -0.50727258 0.85561882 439.75 3.62999566e+00 -3.00442795e+00 4.71205431e+00 -0.69138493 0.83192258 440.00 3.34359681e+00 -3.41421935e+00 4.77875856e+00 -0.79584828 0.85441552 440.25 3.13714419e+00 -4.29666498e+00 5.32005673e+00 -0.94013070 0.83695588 440.50 2.77148781e+00 -4.64329894e+00 5.40752899e+00 -1.03267481 0.83473498 440.75 1.17405619e+00 -5.02866017e+00 5.16389689e+00 -1.34143198 0.80102149 441.00 1.09838671e-01 -4.96709151e+00 4.96830580e+00 -1.54868665 0.85435220 441.25 -5.21090317e-01 -3.69022504e+00 3.72683458e+00 -1.71107712 0.87761780 441.50 -2.45387970e-01 -3.12050677e+00 3.13014021e+00 -1.64927205 0.89284004 441.75 2.41236323e-01 -2.52525222e+00 2.53674865e+00 -1.47555575 0.91296063 442.00 3.97215623e-01 -2.35157026e+00 2.38488216e+00 -1.40346083 0.92575330 442.25 5.80321580e-01 -1.92830696e+00 2.01373804e+00 -1.27846934 0.90883049 442.50 7.11340162e-01 -1.75887306e+00 1.89727153e+00 -1.18647725 0.91114035 442.75 1.04320089e+00 -1.57228733e+00 1.88689045e+00 -0.98499443 0.89850765 443.00 1.31738756e+00 -1.40407294e+00 1.92533914e+00 -0.81723992 0.86637243 443.25 1.91988251e+00 -1.26287999e+00 2.29800233e+00 -0.58183219 0.79898892 443.50 2.24451724e+00 -1.12580542e+00 2.51103474e+00 -0.46491097 0.78522957 443.75 3.15773313e+00 -1.06326212e+00 3.33193710e+00 -0.32479267 0.71092931 444.00 3.48353217e+00 -1.17908488e+00 3.67766740e+00 -0.32636995 0.61711269 444.25 4.69620317e+00 -2.44339871e+00 5.29381917e+00 -0.47974941 0.57340789 444.50 3.87627592e+00 -1.58471419e+00 4.18770033e+00 -0.38808996 0.31019869 444.75 -8.39685417e-01 8.75094648e-01 1.21279110e+00 2.33554799 0.03257333 445.00 -2.38050170e+00 -1.66746822e-01 2.38633460e+00 -3.07165996 0.29059020 445.25 -1.90706781e+00 -1.20610113e+00 2.25645464e+00 -2.57766292 0.70944725 445.50 -1.33550022e+00 -1.59539588e+00 2.08058858e+00 -2.26775135 0.74855165 445.75 -1.00063961e+00 -1.91255299e+00 2.15850378e+00 -2.05282788 0.83252861 446.00 -7.24368255e-01 -2.09753035e+00 2.21908606e+00 -1.90331672 0.86077373 446.25 -4.51331336e-01 -2.40787002e+00 2.44980367e+00 -1.75608639 0.93121481 446.50 -5.17871524e-01 -2.65463005e+00 2.70467219e+00 -1.76345896 0.92339196 446.75 -6.70804052e-01 -3.18696337e+00 3.25679499e+00 -1.77825181 0.93279317 447.00 -8.27568103e-01 -3.39031564e+00 3.48985804e+00 -1.81021217 0.93926488 447.25 -1.02913612e+00 -3.54167196e+00 3.68816505e+00 -1.85358791 0.95798330 447.50 -1.38392888e+00 -3.42995518e+00 3.69862835e+00 -1.95430175 0.96454514 447.75 -1.86887394e+00 -3.16758625e+00 3.67781082e+00 -2.10382998 0.95207139 448.00 -2.29787445e+00 -2.93113885e+00 3.72448680e+00 -2.23567550 0.95498521 448.25 -2.59816963e+00 -2.67716385e+00 3.73064227e+00 -2.34122135 0.95739860 448.50 -2.83590284e+00 -2.06497875e+00 3.50805960e+00 -2.51221911 0.93325918 448.75 -3.03544490e+00 -1.45492373e+00 3.36611479e+00 -2.69463238 0.92575241 449.00 -2.70002717e+00 -8.51690143e-01 2.83116987e+00 -2.83603376 0.83074215 449.25 -2.40396292e+00 -4.27868711e-01 2.44174310e+00 -2.96545242 0.83659977 449.50 -2.09500286e+00 -1.00604171e-01 2.09741703e+00 -3.09360850 0.80790029 449.75 -1.85371175e+00 9.48224287e-02 1.85613538e+00 3.09048446 0.81491319 450.00 -1.36080026e+00 1.86409678e-01 1.37350861e+00 3.00545464 0.77065365 450.25 -1.16539689e+00 1.96230317e-01 1.18180212e+00 2.97477676 0.79458535 450.50 -1.15083517e+00 1.69353190e-01 1.16322916e+00 2.99548452 0.82152397 450.75 -9.90255333e-01 1.58268236e-01 1.00282324e+00 2.98310736 0.75557288 451.00 -7.70648869e-01 2.20946383e-01 8.01696316e-01 2.86238029 0.78391273 451.25 -7.14353101e-01 2.15157120e-01 7.46051566e-01 2.84904305 0.82697683 451.50 -7.09975489e-01 2.08870016e-01 7.40062077e-01 2.85547160 0.73139629 451.75 -7.42447348e-01 2.65685475e-01 7.88553636e-01 2.79794088 0.67916430 452.00 -8.97480940e-01 5.67792308e-01 1.06200760e+00 2.57751033 0.74729318 452.25 -9.69164103e-01 6.99126229e-01 1.19501320e+00 2.51666770 0.77351423 452.50 -7.63873530e-01 1.00564417e+00 1.26286300e+00 2.22040449 0.79595870 452.75 -7.05951925e-01 9.79964643e-01 1.20776605e+00 2.19507295 0.68269600 453.00 -6.14535641e-01 1.33719245e+00 1.47164455e+00 2.00158141 0.75277902 453.25 -5.84384019e-01 1.40498321e+00 1.52167096e+00 1.96496527 0.68521658 453.50 -7.01884090e-01 1.48409165e+00 1.64169708e+00 2.01256133 0.62918532 453.75 -7.21031784e-01 1.76362729e+00 1.90532623e+00 1.95889543 0.67119828 454.00 -1.03138879e+00 1.90361643e+00 2.16506774e+00 2.06732598 0.54949033 454.25 -1.45230307e+00 2.24714371e+00 2.67560069e+00 2.14455796 0.54659827 454.50 -2.89648973e+00 2.33444009e+00 3.72011604e+00 2.46323121 0.50708564 454.75 -3.23604757e+00 2.23660594e+00 3.93375266e+00 2.53682858 0.47853490 455.00 -2.68521774e+00 3.61957342e+00 4.50685102e+00 2.20906763 0.35755874 455.25 -2.58211371e+00 3.38027621e+00 4.25365471e+00 2.22311943 0.27618357 455.50 -2.31584229e+00 1.77870273e+00 2.92008715e+00 2.48663382 0.14571155 455.75 -1.75803586e+00 1.19995564e+00 2.12851677e+00 2.54267115 0.09562338 456.00 -2.28445275e+00 1.90365609e+00 2.97365614e+00 2.44686847 0.20943640 456.25 -2.87873229e+00 2.02118052e+00 3.51742382e+00 2.52945343 0.32889892 456.50 -3.87975010e+00 1.08893222e+00 4.02966924e+00 2.86796211 0.51351674 456.75 -4.34428690e+00 1.02111216e+00 4.46267842e+00 2.91073603 0.68619358 457.00 -4.50632889e+00 2.21418300e-01 4.51176530e+00 3.09249718 0.82120334 457.25 -4.33850194e+00 -5.04733287e-01 4.36776313e+00 -3.02577514 0.85875661 457.50 -4.21547880e+00 -1.05307400e+00 4.34502318e+00 -2.89679165 0.92083701 457.75 -3.55331688e+00 -1.39668460e+00 3.81795610e+00 -2.76707896 0.92149314 458.00 -3.33417837e+00 -1.49604555e+00 3.65443534e+00 -2.71982041 0.93735787 458.25 -3.17314273e+00 -1.72912724e+00 3.61368452e+00 -2.64265355 0.91958007 458.50 -3.01870857e+00 -1.99289099e+00 3.61721107e+00 -2.55809428 0.93153510 458.75 -2.76762067e+00 -1.93141192e+00 3.37491869e+00 -2.53230433 0.92701441 459.00 -2.60102584e+00 -1.88619684e+00 3.21295409e+00 -2.51417029 0.91715624 459.25 -2.67133329e+00 -1.94066241e+00 3.30184678e+00 -2.51331696 0.94035453 459.50 -2.68217077e+00 -1.94400017e+00 3.31257855e+00 -2.51442466 0.95332195 459.75 -2.52104827e+00 -2.03552377e+00 3.24022243e+00 -2.46234872 0.94571032 460.00 -2.61440810e+00 -1.93938160e+00 3.25520056e+00 -2.50335686 0.94854608 460.25 -2.72746023e+00 -1.88928211e+00 3.31789484e+00 -2.53579017 0.93314741 460.50 -2.74089938e+00 -1.91620554e+00 3.34430457e+00 -2.53146049 0.93667641 460.75 -2.84412116e+00 -1.77085486e+00 3.35036597e+00 -2.58469443 0.94365232 461.00 -2.90983013e+00 -1.46205619e+00 3.25648886e+00 -2.67598366 0.93844659 461.25 -2.82791610e+00 -1.07607905e+00 3.02573224e+00 -2.77799121 0.93693322 461.50 -2.69725476e+00 -1.02900914e+00 2.88687427e+00 -2.77713348 0.91987957 461.75 -2.68279008e+00 -7.03006050e-01 2.77336982e+00 -2.88531202 0.93147686 462.00 -2.67432366e+00 -5.26114714e-01 2.72558319e+00 -2.94734509 0.94979321 462.25 -2.47185392e+00 -3.13376712e-01 2.49163937e+00 -3.01548739 0.93307337 462.50 -2.34479016e+00 -3.00792464e-01 2.36400444e+00 -3.01400827 0.92251452 462.75 -2.03786525e+00 -1.60370755e-01 2.04416573e+00 -3.06305904 0.90915222 463.00 -1.93774393e+00 -2.03059569e-01 1.94835436e+00 -3.03718198 0.91302671 463.25 -1.79122948e+00 -3.38505694e-01 1.82293422e+00 -2.95481581 0.93482947 463.50 -1.81371693e+00 -3.68638026e-01 1.85080067e+00 -2.94107402 0.91619266 463.75 -1.86410566e+00 -3.34233602e-01 1.89383262e+00 -2.96417811 0.93081829 464.00 -1.82687176e+00 -3.44113160e-01 1.85899820e+00 -2.95541214 0.91793840 464.25 -1.81823176e+00 -2.72601291e-01 1.83855329e+00 -2.99277450 0.90651554 464.50 -1.82710543e+00 -1.85988044e-01 1.83654725e+00 -3.04014826 0.92062869 464.75 -1.82647800e+00 -9.29922210e-02 1.82884374e+00 -3.09072317 0.91714750 465.00 -1.79609683e+00 -1.52229706e-02 1.79616134e+00 -3.13311727 0.92839483 465.25 -1.57760379e+00 1.34102172e-01 1.58329312e+00 3.05679280 0.91611191 465.50 -1.47969095e+00 1.54560011e-01 1.48774127e+00 3.03751582 0.92908381 465.75 -1.39538950e+00 1.92908385e-01 1.40866089e+00 3.00421644 0.94783787 466.00 -1.37940241e+00 2.07508269e-01 1.39492318e+00 2.99227882 0.95158797 466.25 -1.31537431e+00 2.15840728e-01 1.33296542e+00 2.97895134 0.95282693 466.50 -1.25298187e+00 2.37361152e-01 1.27526620e+00 2.95437413 0.95223087 466.75 -1.20757622e+00 2.62134307e-01 1.23570010e+00 2.92783426 0.96060665 467.00 -1.16764222e+00 2.91200994e-01 1.20340616e+00 2.89718601 0.95250575 467.25 -1.14255127e+00 3.63045551e-01 1.19884339e+00 2.83393213 0.96420824 467.50 -1.03159478e+00 3.92189122e-01 1.10363041e+00 2.77829055 0.96278924 467.75 -1.00374511e+00 4.17853770e-01 1.08724699e+00 2.74711852 0.98079008 468.00 -9.58903162e-01 4.42972991e-01 1.05627664e+00 2.70883907 0.96819392 468.25 -9.31902456e-01 5.06349186e-01 1.06058082e+00 2.64386935 0.96703434 468.50 -8.79628833e-01 5.66669616e-01 1.04635622e+00 2.56929535 0.94785145 468.75 -8.17422636e-01 6.54782385e-01 1.04733936e+00 2.46622224 0.95438310 469.00 -7.52632520e-01 7.01210061e-01 1.02866479e+00 2.39154978 0.95222087 469.25 -6.92927136e-01 7.65188973e-01 1.03230915e+00 2.30667665 0.95400202 469.50 -5.81858207e-01 8.46654511e-01 1.02731827e+00 2.17290980 0.93401480 469.75 -4.78467580e-01 9.05379208e-01 1.02403259e+00 2.05696126 0.93445692 470.00 -4.17986123e-01 9.81365195e-01 1.06667242e+00 1.97344860 0.91517075 470.25 -3.17384616e-01 9.95264372e-01 1.04464547e+00 1.87949639 0.90010166 470.50 -1.10297905e-01 1.05370899e+00 1.05946602e+00 1.67509238 0.90956169 470.75 -2.91743622e-02 1.11103360e+00 1.11141658e+00 1.59704905 0.93498285 471.00 1.82741979e-01 1.14965656e+00 1.16408970e+00 1.41316157 0.92299129 471.25 3.23516660e-01 1.18972902e+00 1.23293073e+00 1.30529148 0.93483109 471.50 5.31429109e-01 1.17901887e+00 1.29325265e+00 1.14732850 0.92365726 471.75 6.90680339e-01 1.14660403e+00 1.33855898e+00 1.02863570 0.92593620 472.00 9.88600754e-01 1.08183895e+00 1.46550570e+00 0.83040080 0.91838786 472.25 1.13194796e+00 1.01017561e+00 1.51715555e+00 0.72861272 0.93378792 472.50 1.47031836e+00 7.89571179e-01 1.66890945e+00 0.49281304 0.94113274 472.75 1.59208349e+00 7.00716988e-01 1.73946375e+00 0.41461225 0.95784035 473.00 1.76982237e+00 4.60178454e-01 1.82867040e+00 0.25438110 0.96156067 473.25 1.85353143e+00 2.78380432e-01 1.87431972e+00 0.14907499 0.96357066 473.50 1.88070465e+00 -5.02942244e-02 1.88137702e+00 -0.02673585 0.96084929 473.75 1.94079842e+00 -2.52436274e-01 1.95714654e+00 -0.12934213 0.94528184 474.00 1.97538891e+00 -6.78989282e-01 2.08882450e+00 -0.33107314 0.95596115 474.25 1.91208375e+00 -8.88994367e-01 2.10864299e+00 -0.43520410 0.95791923 474.50 1.68506720e+00 -1.14890706e+00 2.03947025e+00 -0.59841792 0.95482925 474.75 1.59011338e+00 -1.21365382e+00 2.00035401e+00 -0.65192723 0.95320751 475.00 1.34345538e+00 -1.38942854e+00 1.93271417e+00 -0.80221879 0.93226003 475.25 1.22266645e+00 -1.33519078e+00 1.81042748e+00 -0.82936145 0.91899691 475.50 9.84539912e-01 -1.37422760e+00 1.69050890e+00 -0.94912744 0.89587548 475.75 9.02834356e-01 -1.40016812e+00 1.66600739e+00 -0.99808233 0.89536160 476.00 6.99625703e-01 -1.31537544e+00 1.48986197e+00 -1.08196891 0.86303026 476.25 5.69860874e-01 -1.28497849e+00 1.40567106e+00 -1.15337855 0.86850884 476.50 3.79279593e-01 -1.28252672e+00 1.33743329e+00 -1.28326301 0.85418078 476.75 3.25062582e-01 -1.21966314e+00 1.26223764e+00 -1.31033243 0.82112512 477.00 1.89772904e-01 -9.67471629e-01 9.85908265e-01 -1.37710209 0.76034021 477.25 2.78877439e-01 -7.94119058e-01 8.41663653e-01 -1.23307212 0.66734818 477.50 4.64188426e-01 -5.50865579e-01 7.20363645e-01 -0.87058318 0.64205665 477.75 5.66066574e-01 -5.24553568e-01 7.71743359e-01 -0.74735286 0.70117070 478.00 7.89171108e-01 -6.12059748e-01 9.98703245e-01 -0.65966791 0.82525845 478.25 8.58308428e-01 -6.85584678e-01 1.09850795e+00 -0.67398598 0.89402784 478.50 9.23942684e-01 -7.79305220e-01 1.20871283e+00 -0.70068278 0.91520601 478.75 1.08169620e+00 -8.24794922e-01 1.36027693e+00 -0.65145415 0.89712372 479.00 1.32341057e+00 -9.75992164e-01 1.64437716e+00 -0.63544167 0.91783267 479.25 1.40911000e+00 -1.28567192e+00 1.90749660e+00 -0.73962383 0.91950679 479.50 1.25904084e+00 -1.61061238e+00 2.04432289e+00 -0.90730426 0.94281955 479.75 1.03912679e+00 -1.82016710e+00 2.09589904e+00 -1.05205150 0.93825989 480.00 8.56021837e-01 -1.98168567e+00 2.15866891e+00 -1.16303981 0.95086668 480.25 6.85698185e-01 -1.97324010e+00 2.08898504e+00 -1.23635166 0.95291103 480.50 5.80608937e-01 -1.98437359e+00 2.06756990e+00 -1.28615099 0.95386213 480.75 4.42477601e-01 -2.02623780e+00 2.07398796e+00 -1.35579751 0.95181993 481.00 3.80910551e-01 -2.01430818e+00 2.05000739e+00 -1.38390083 0.95396044 481.25 2.36294477e-01 -2.00366949e+00 2.01755458e+00 -1.45340766 0.94996988 481.50 2.99719887e-02 -1.99016215e+00 1.99038782e+00 -1.55573739 0.93914542 481.75 -2.41625601e-01 -1.79133355e+00 1.80755604e+00 -1.70487298 0.92342131 482.00 -2.56618217e-01 -1.57247518e+00 1.59327684e+00 -1.73256412 0.89268924 482.25 -1.44157241e-01 -1.28794262e+00 1.29598515e+00 -1.68226071 0.85446912 482.50 2.55545480e-02 -1.18177123e+00 1.18204750e+00 -1.54917576 0.83326787 482.75 4.60123087e-01 -1.25339877e+00 1.33518603e+00 -1.21896933 0.79098798 483.00 6.96546641e-01 -1.62163166e+00 1.76489843e+00 -1.16509125 0.82415406 483.25 5.02065365e-01 -2.21262865e+00 2.26887531e+00 -1.34766561 0.86266640 483.50 2.62124372e-01 -2.59375279e+00 2.60696427e+00 -1.47007839 0.89699890 483.75 -1.07493528e-01 -2.92009324e+00 2.92207107e+00 -1.60759139 0.86699880 484.00 -7.82283022e-01 -2.86297809e+00 2.96793030e+00 -1.83752648 0.82627518 484.25 -1.74585995e+00 -1.90851148e+00 2.58658907e+00 -2.31171509 0.81615509 484.50 -1.74272509e+00 -1.41585661e+00 2.24538208e+00 -2.45931327 0.80927670 484.75 -1.42887255e+00 -9.42949454e-01 1.71196683e+00 -2.55827153 0.81095971 485.00 -1.09815419e+00 -8.98922186e-01 1.41915599e+00 -2.45562733 0.80548147 485.25 -8.43226447e-01 -1.28028050e+00 1.53301957e+00 -2.15321187 0.85278793 485.50 -8.58780763e-01 -1.46047012e+00 1.69424832e+00 -2.10235795 0.89920816 485.75 -1.20049054e+00 -1.44629423e+00 1.87961287e+00 -2.26359132 0.94734436 486.00 -1.37831202e+00 -1.36933365e+00 1.94288926e+00 -2.35946214 0.93586294 486.25 -1.64858855e+00 -1.11255958e+00 1.98887733e+00 -2.54794204 0.94622882 486.50 -1.67674165e+00 -9.40994519e-01 1.92274107e+00 -2.63018806 0.93154663 486.75 -1.59032555e+00 -6.70028311e-01 1.72570950e+00 -2.74284721 0.93858278 487.00 -1.59848598e+00 -6.65510599e-01 1.73149120e+00 -2.74708154 0.92231086 487.25 -1.56617301e+00 -5.91195127e-01 1.67403989e+00 -2.78065167 0.92281625 487.50 -1.59873368e+00 -4.87172582e-01 1.67131281e+00 -2.84580753 0.92127715 487.75 -1.64154137e+00 -3.69464702e-01 1.68260579e+00 -2.92020985 0.94841545 488.00 -1.64138823e+00 -2.74914868e-01 1.66425164e+00 -2.97564374 0.92705775 488.25 -1.60775327e+00 -1.24383473e-01 1.61255754e+00 -3.06438168 0.90874427 488.50 -1.74038639e+00 1.87747608e-02 1.74048766e+00 3.13080538 0.87313447 488.75 -1.73703784e+00 3.41618384e-02 1.73737374e+00 3.12192847 0.86805409 489.00 -1.80963531e+00 1.38427162e-01 1.81492205e+00 3.06524682 0.85571011 489.25 -2.01393728e+00 9.57384171e-02 2.01621160e+00 3.09409048 0.88595512 489.50 -2.25189355e+00 3.11171240e-01 2.27329103e+00 3.00428017 0.86872205 489.75 -2.53373686e+00 9.08417398e-01 2.69166206e+00 2.79734017 0.90337460 490.00 -2.62575715e+00 1.44341297e+00 2.99633803e+00 2.63896978 0.91547376 490.25 -2.65955956e+00 1.93656908e+00 3.28991745e+00 2.51222017 0.92436659 490.50 -2.52712220e+00 2.73450092e+00 3.72341804e+00 2.31680143 0.89757718 490.75 -2.40405463e+00 3.47369682e+00 4.22445834e+00 2.17618288 0.93742569 491.00 -1.68238760e+00 4.45286899e+00 4.76009141e+00 1.93203794 0.90262594 491.25 -7.22541516e-01 5.32321961e+00 5.37203251e+00 1.70570578 0.93031820 491.50 8.86015247e-01 5.31431180e+00 5.38766489e+00 1.40559334 0.90415046 491.75 1.93033611e+00 4.91844763e+00 5.28368475e+00 1.19679937 0.89897989 492.00 3.12782219e+00 4.00956483e+00 5.08526123e+00 0.90831396 0.89364798 492.25 3.60113770e+00 3.46946887e+00 5.00054067e+00 0.76677832 0.91210974 492.50 3.82205830e+00 2.27643997e+00 4.44862997e+00 0.53718218 0.90079827 492.75 4.19428411e+00 1.69074231e+00 4.52223714e+00 0.38318134 0.93563067 493.00 4.23304221e+00 8.28669946e-01 4.31339080e+00 0.19331752 0.93177500 493.25 4.26980976e+00 5.78045357e-01 4.30875989e+00 0.13456157 0.94495220 493.50 4.22681069e+00 -5.77708938e-02 4.22720547e+00 -0.01366688 0.95251085 493.75 4.12905909e+00 -2.89195511e-01 4.13917420e+00 -0.06992489 0.95517782 494.00 3.65118134e+00 -9.25157654e-01 3.76656898e+00 -0.24816279 0.95355235 494.25 3.58647678e+00 -1.07086900e+00 3.74293683e+00 -0.29015834 0.96556338 494.50 3.19920368e+00 -1.36003106e+00 3.47628949e+00 -0.40196847 0.94400399 494.75 2.93717838e+00 -1.59121119e+00 3.34050443e+00 -0.49648581 0.94595525 495.00 2.56010836e+00 -1.79201958e+00 3.12497824e+00 -0.61071121 0.96438001 495.25 2.38951094e+00 -1.88089671e+00 3.04097599e+00 -0.66685455 0.96592457 495.50 2.04129119e+00 -1.94438445e+00 2.81913118e+00 -0.76108920 0.96456382 495.75 1.86131763e+00 -1.93969862e+00 2.68829575e+00 -0.80601630 0.96123286 496.00 1.41639978e+00 -1.85561325e+00 2.33441403e+00 -0.91883395 0.95484724 496.25 1.22586199e+00 -1.73813865e+00 2.12693761e+00 -0.95654030 0.93451403 496.50 8.53087383e-01 -1.50073699e+00 1.72625884e+00 -1.05390178 0.92141179 496.75 7.89060556e-01 -1.32244036e+00 1.53995619e+00 -1.03282892 0.88401635 497.00 8.61903485e-01 -9.56293631e-01 1.28739082e+00 -0.83726575 0.87107415 497.25 9.25996308e-01 -9.19474103e-01 1.30495279e+00 -0.78186401 0.88514224 497.50 9.61206873e-01 -8.09640535e-01 1.25675632e+00 -0.70001653 0.88598313 497.75 1.03291012e+00 -7.66670393e-01 1.28634631e+00 -0.63851817 0.87029840 498.00 1.07465985e+00 -7.17913793e-01 1.29239855e+00 -0.58895150 0.86214928 498.25 1.09146090e+00 -7.16126173e-01 1.30542085e+00 -0.58066346 0.87239100 498.50 1.19522495e+00 -5.65352903e-01 1.32219007e+00 -0.44182311 0.86759151 498.75 1.24262651e+00 -5.68064974e-01 1.36631565e+00 -0.42878278 0.85811610 499.00 1.31352262e+00 -6.13789777e-01 1.44985502e+00 -0.43713502 0.85329932 499.25 1.27681537e+00 -6.58468499e-01 1.43660651e+00 -0.47613774 0.84369666 499.50 1.25011972e+00 -5.26512022e-01 1.35647124e+00 -0.39862152 0.83308577 499.75 1.19503816e+00 -4.42529895e-01 1.27434254e+00 -0.35464911 0.81912937 500.00 1.12474510e+00 -4.09759574e-01 1.19706076e+00 -0.34936873 0.82563248 500.25 1.11714223e+00 -1.82764567e-01 1.13199366e+00 -0.16216350 0.78928328 500.50 1.14320507e+00 2.87021465e-06 1.14320507e+00 0.00000251 0.85158104 500.75 1.14610251e+00 1.10088520e-01 1.15137763e+00 0.09576090 0.86188141 501.00 1.20813023e+00 2.44298793e-01 1.23258288e+00 0.19952186 0.85596214 501.25 1.23944904e+00 4.68219103e-01 1.32493888e+00 0.36119161 0.83978719 501.50 1.37823481e+00 6.40931073e-01 1.51997494e+00 0.43528863 0.88994149 501.75 1.41139452e+00 8.95389458e-01 1.67145349e+00 0.56533072 0.88861028 502.00 1.44513819e+00 1.20044740e+00 1.87869592e+00 0.69317034 0.90214698 502.25 1.62067047e+00 1.48673585e+00 2.19930814e+00 0.74232309 0.90916936 502.50 1.69667171e+00 1.73821147e+00 2.42900679e+00 0.79749107 0.90172826 502.75 1.77464706e+00 2.28739354e+00 2.89508918e+00 0.91096286 0.87217376 503.00 1.93087104e+00 2.96450237e+00 3.53787185e+00 0.99348630 0.91998028 503.25 2.22290044e+00 3.68878585e+00 4.30678853e+00 1.02845968 0.91491911 503.50 2.47235986e+00 4.37728591e+00 5.02724529e+00 1.05664949 0.92622418 503.75 3.21322496e+00 5.13369008e+00 6.05636760e+00 1.01154332 0.90729146 504.00 3.64888706e+00 5.36033058e+00 6.48440596e+00 0.97312713 0.91556972 504.25 4.13562057e+00 5.53113442e+00 6.90628739e+00 0.92876984 0.91683477 504.50 3.75596593e+00 6.21108805e+00 7.25843611e+00 1.02691385 0.91927601 504.75 3.16407894e+00 7.32662063e+00 7.98064943e+00 1.16312905 0.88558509 505.00 2.14516566e+00 8.32363846e+00 8.59562057e+00 1.31856536 0.85776145 505.25 6.57034828e-01 9.40336754e+00 9.42629385e+00 1.50103741 0.84453831 505.50 -4.89779882e-01 1.02725251e+01 1.02841945e+01 1.61843887 0.83161736 505.75 -2.91160724e+00 1.01176364e+01 1.05282488e+01 1.85100054 0.76421681 506.00 -4.88514141e+00 9.25460735e+00 1.04648155e+01 2.05648310 0.71531884 506.25 -7.00387389e+00 8.33310188e+00 1.08855334e+01 2.26974232 0.66787609 506.50 -6.70339023e+00 6.62036250e+00 9.42149883e+00 2.36242597 0.52351543 506.75 -3.73530553e+00 7.11316119e+00 8.03427467e+00 2.05434206 0.61402276 507.00 -3.40734205e+00 5.98000223e+00 6.88261626e+00 2.08870591 0.64995594 507.25 -5.14090692e+00 4.75538573e+00 7.00304344e+00 2.39513092 0.72314238 507.50 -5.47838565e+00 4.00318132e+00 6.78514333e+00 2.51054353 0.76915947 507.75 -6.61550302e+00 3.10740838e+00 7.30895800e+00 2.70246431 0.87885766 508.00 -5.99916223e+00 2.55383391e+00 6.52012386e+00 2.73913058 0.85597897 508.25 -5.08568347e+00 1.73425778e+00 5.37325101e+00 2.81295104 0.83955871 508.50 -4.88771189e+00 1.94291678e+00 5.25971987e+00 2.76323424 0.84729102 508.75 -4.08076755e+00 1.51071639e+00 4.35142825e+00 2.78703333 0.82593187 509.00 -3.79682792e+00 9.30281586e-01 3.90913368e+00 2.90131078 0.85010552 509.25 -3.84683127e+00 5.12931443e-01 3.88087741e+00 3.00903586 0.91598089 509.50 -3.69137143e+00 4.28523464e-01 3.71616138e+00 3.02602208 0.91421098 509.75 -3.55263410e+00 2.41803800e-01 3.56085357e+00 3.07363422 0.91472384 510.00 -3.18686110e+00 -9.27178666e-02 3.18820957e+00 -3.11250707 0.85730426 510.25 -2.66624032e+00 -5.64846478e-01 2.72541538e+00 -2.93282802 0.87006586 510.50 -2.27963085e+00 -6.37632827e-01 2.36712746e+00 -2.86885399 0.86793153 510.75 -2.06040456e+00 -8.14075323e-01 2.21539739e+00 -2.76531356 0.88596000 511.00 -1.69858106e+00 -1.10719556e+00 2.02757481e+00 -2.56392813 0.77761330 511.25 -1.29113329e+00 -1.53402212e+00 2.00505587e+00 -2.27043176 0.68895155 511.50 -1.50527040e+00 -1.78843751e+00 2.33759442e+00 -2.27043323 0.68824795 511.75 -1.82957192e+00 -2.02635343e+00 2.73009920e+00 -2.30520519 0.73970557 512.00 -2.20696241e+00 -2.19359330e+00 3.11167714e+00 -2.35923253 0.69462327 512.25 -2.25799312e+00 -2.49688227e+00 3.36644531e+00 -2.30599581 0.66878498 512.50 -2.21019852e+00 -2.73299603e+00 3.51486057e+00 -2.25082513 0.64103857 512.75 -2.24572722e+00 -2.69992679e+00 3.51182223e+00 -2.26461327 0.64293938 513.00 -1.90346637e+00 -2.36931622e+00 3.03921760e+00 -2.24759616 0.59883880 513.25 -1.99174976e+00 -2.29897284e+00 3.04176646e+00 -2.28471477 0.60120836 513.50 -1.31865266e+00 -1.98409986e+00 2.38233019e+00 -2.15737375 0.35556142 513.75 -2.25884894e-01 -2.03686769e+00 2.04935452e+00 -1.68124320 0.29821903 514.00 7.97609239e-01 -1.59001316e+00 1.77885422e+00 -1.10584007 0.24842599 514.25 1.41755439e+00 -1.49307669e+00 2.05881967e+00 -0.81133940 0.34568296 514.50 2.07041971e+00 -1.20016826e+00 2.39312382e+00 -0.52533974 0.55054522 514.75 2.37326371e+00 -3.19197916e-01 2.39463315e+00 -0.13369514 0.54181099 515.00 1.60347273e+00 9.34385113e-01 1.85585569e+00 0.52762112 0.42770488 515.25 1.44076578e+00 1.21074610e+00 1.88194371e+00 0.69886442 0.54708617 515.50 1.13188176e+00 1.77751011e+00 2.10729650e+00 1.00377126 0.64692111 515.75 9.90539227e-01 2.13813251e+00 2.35643344e+00 1.13695949 0.71091262 516.00 3.98318826e-01 2.51870933e+00 2.55001070e+00 1.41395124 0.75920004 516.25 2.90405947e-01 2.62935667e+00 2.64534537e+00 1.46079464 0.79554983 516.50 1.15441423e-01 2.87254824e+00 2.87486698e+00 1.53063013 0.81177216 516.75 1.12989659e-02 2.91281485e+00 2.91283677e+00 1.56691729 0.84045512 517.00 1.97721977e-01 2.65992299e+00 2.66726157e+00 1.49659906 0.77487771 517.25 2.53847888e-01 2.53937961e+00 2.55203596e+00 1.47116279 0.77258243 517.50 4.03917164e-01 2.57850937e+00 2.60995396e+00 1.41541154 0.80759263 517.75 2.97800111e-01 2.20071232e+00 2.22077005e+00 1.43629346 0.74538558 518.00 -2.52512267e-01 1.81191461e+00 1.82942532e+00 1.70926660 0.73443553 518.25 -2.86928648e-01 1.77853296e+00 1.80152923e+00 1.73074698 0.69903189 518.50 -1.02286756e-01 1.96128845e+00 1.96395391e+00 1.62290196 0.73781595 518.75 5.86537904e-02 1.99455509e+00 1.99541732e+00 1.54139784 0.73023043 519.00 2.03848404e-01 2.10673240e+00 2.11657166e+00 1.47433615 0.79699100 519.25 1.63033771e-01 2.12045878e+00 2.12671706e+00 1.49406121 0.84110525 519.50 1.62632182e-01 2.08231041e+00 2.08865168e+00 1.49285276 0.83473629 519.75 2.33225520e-01 2.05498531e+00 2.06817764e+00 1.45778733 0.85858762 520.00 3.69194521e-01 2.09565632e+00 2.12792857e+00 1.39641438 0.87470631 520.25 6.00478362e-01 2.22900215e+00 2.30846807e+00 1.30765001 0.86449221 520.50 8.86239935e-01 2.29419057e+00 2.45941692e+00 1.20215803 0.84816454 520.75 1.39810083e+00 1.89802048e+00 2.35736456e+00 0.93592005 0.81442089 521.00 1.81247632e+00 1.36027966e+00 2.26614897e+00 0.64382674 0.84915427 521.25 2.04570884e+00 4.46182952e-01 2.09380130e+00 0.21474376 0.74079526 521.50 1.89850592e+00 -5.05772029e-01 1.96472137e+00 -0.26035836 0.70046755 521.75 7.15635889e-01 -1.21453441e+00 1.40969094e+00 -1.03833616 0.47393624 522.00 -1.79812756e-01 -1.53416118e+00 1.54466280e+00 -1.68746992 0.60841457 522.25 -1.06022424e+00 -6.16283193e-01 1.22632802e+00 -2.61505438 0.36499956 522.50 -1.42340842e+00 3.39765577e-01 1.46339748e+00 2.90727857 0.61125735 522.75 -1.48150709e+00 7.99739079e-01 1.68358126e+00 2.64660299 0.67730312 523.00 -1.50529962e+00 1.20714866e+00 1.92954265e+00 2.46567448 0.79820453 523.25 -9.86703553e-01 1.52599716e+00 1.81720974e+00 2.14477480 0.79340548 523.50 -7.93314669e-01 1.80261717e+00 1.96946105e+00 1.98537901 0.85690086 523.75 -2.72499161e-01 2.09839998e+00 2.11601944e+00 1.69993410 0.79988566 524.00 4.14446198e-01 2.37686007e+00 2.41272241e+00 1.39816482 0.86095576 524.25 8.13405255e-01 2.36529347e+00 2.50124795e+00 1.23957336 0.86560621 524.50 1.19472731e+00 2.07408476e+00 2.39357493e+00 1.04819112 0.83690753 524.75 1.64540487e+00 1.44416615e+00 2.18928597e+00 0.72035520 0.86389982 525.00 1.80391883e+00 1.16669174e+00 2.14832325e+00 0.57408994 0.89546096 525.25 1.78795417e+00 6.23515350e-01 1.89355525e+00 0.33554401 0.76675975 525.50 1.82909691e+00 3.13531575e-01 1.85577411e+00 0.16976346 0.80398495 525.75 1.58875275e+00 -8.71521034e-02 1.59114134e+00 -0.05480075 0.79573468 526.00 1.32512442e+00 -2.97596431e-01 1.35813047e+00 -0.22091464 0.77444889 526.25 1.06593677e+00 -5.88204027e-01 1.21745849e+00 -0.50423859 0.82019777 526.50 9.29546856e-01 -5.39935938e-01 1.07498287e+00 -0.52622655 0.78605139 526.75 7.43772368e-01 -5.07445345e-01 9.00387757e-01 -0.59871971 0.81251596 527.00 5.71694480e-01 -5.36385623e-01 7.83928642e-01 -0.75354405 0.79023612 527.25 4.07579188e-01 -4.70702553e-01 6.22640898e-01 -0.85714623 0.79111222 527.50 3.83341524e-01 -4.19393135e-01 5.68191276e-01 -0.83027900 0.78843225 527.75 3.08853484e-01 -3.33965033e-01 4.54888027e-01 -0.82444307 0.73497003 528.00 2.81623904e-01 -3.31763378e-01 4.35176932e-01 -0.86695878 0.71680472 528.25 2.14872548e-01 -3.45940535e-01 4.07240796e-01 -1.01498790 0.74069005 528.50 2.02143206e-01 -3.25773709e-01 3.83393251e-01 -1.01543814 0.78078738 528.75 1.80460332e-01 -3.05510830e-01 3.54827844e-01 -1.03725505 0.82497822 529.00 1.49885432e-01 -2.86600102e-01 3.23427367e-01 -1.08893607 0.78774584 529.25 1.58209333e-01 -2.57363481e-01 3.02102887e-01 -1.01961550 0.81498716 529.50 1.50518959e-01 -2.49053430e-01 2.91004412e-01 -1.02717408 0.80792941 529.75 1.51241113e-01 -2.42596228e-01 2.85879003e-01 -1.01332874 0.86877760 530.00 1.46761368e-01 -2.28148102e-01 2.71275608e-01 -0.99916510 0.78727557 530.25 1.45927049e-01 -2.19246510e-01 2.63369960e-01 -0.98354338 0.78309185 530.50 1.46424144e-01 -2.24846884e-01 2.68320985e-01 -0.99356595 0.77501428 530.75 1.50990008e-01 -2.02867783e-01 2.52889937e-01 -0.93096743 0.79053486 531.00 1.48795277e-01 -2.29902311e-01 2.73852346e-01 -0.99638432 0.79975748 531.25 1.60237983e-01 -2.16604495e-01 2.69432215e-01 -0.93387321 0.77292271 531.50 1.60378312e-01 -2.04444911e-01 2.59844039e-01 -0.90560473 0.70647851 531.75 1.71966351e-01 -1.82265394e-01 2.50585513e-01 -0.81446428 0.69083040 532.00 1.85600401e-01 -1.59040964e-01 2.44420820e-01 -0.70848619 0.67751033 532.25 2.00119069e-01 -1.26353678e-01 2.36670433e-01 -0.56318296 0.66388659 532.50 3.08152875e-01 -1.47717849e-01 3.41729070e-01 -0.44700414 0.76168117 532.75 3.91067411e-01 -1.56492224e-01 4.21216733e-01 -0.38065023 0.84978974 533.00 4.27170792e-01 -1.86110221e-01 4.65952680e-01 -0.41088270 0.88577922 533.25 4.51099731e-01 -2.54730416e-01 5.18052654e-01 -0.51404969 0.91469971 533.50 4.73497361e-01 -3.19999844e-01 5.71488977e-01 -0.59431403 0.91694091 533.75 5.04043319e-01 -3.56229141e-01 6.17218656e-01 -0.61523722 0.93089831 534.00 5.22726361e-01 -4.89691943e-01 7.16268838e-01 -0.75278052 0.89841402 534.25 5.42603740e-01 -6.03178833e-01 8.11322084e-01 -0.83821687 0.90660355 534.50 4.97652595e-01 -7.18062234e-01 8.73654094e-01 -0.96475045 0.93021128 534.75 4.61025337e-01 -7.87862689e-01 9.12837323e-01 -1.04136043 0.94040552 535.00 3.92944939e-01 -9.17368323e-01 9.97983148e-01 -1.16610063 0.91139085 535.25 2.88075712e-01 -1.04916013e+00 1.08799108e+00 -1.30282300 0.92166730 535.50 1.22322850e-01 -1.06417132e+00 1.07117855e+00 -1.45635203 0.92050367 535.75 2.05157772e-02 -1.08441378e+00 1.08460783e+00 -1.55187981 0.89566563 536.00 -2.59980484e-01 -1.00959585e+00 1.04253232e+00 -1.82283014 0.89564189 536.25 -3.45403957e-01 -9.25460979e-01 9.87816743e-01 -1.92800877 0.92141557 536.50 -4.61071898e-01 -8.11284003e-01 9.33150057e-01 -2.08759869 0.88272991 536.75 -5.06996975e-01 -7.17651985e-01 8.78675312e-01 -2.18584895 0.86697188 537.00 -5.45437379e-01 -5.32944081e-01 7.62582014e-01 -2.36777920 0.77694439 537.25 -5.63958060e-01 -4.38698700e-01 7.14496496e-01 -2.48047806 0.68651380 537.50 -5.36010803e-01 -1.96784734e-01 5.70991955e-01 -2.78974100 0.55134351 537.75 -3.95209412e-01 -1.57779294e-02 3.95524238e-01 -3.10169088 0.28854185 538.00 2.09903808e-02 3.01316622e-01 3.02046855e-01 1.50124648 0.10081044 538.25 3.23237844e-01 1.52799880e-01 3.57533924e-01 0.44158360 0.08465596 538.50 8.01776478e-01 -6.56630710e-01 1.03634425e+00 -0.68620133 0.52431614 538.75 7.01241301e-01 -8.37154915e-01 1.09204749e+00 -0.87351697 0.65057051 539.00 6.84755471e-01 -7.45092227e-01 1.01195478e+00 -0.82757117 0.66913833 539.25 6.55991685e-01 -9.68865362e-01 1.17005349e+00 -0.97562453 0.55804398 539.50 1.92808622e-01 -1.37715951e+00 1.39059105e+00 -1.43169590 0.55008393 539.75 -5.00537541e-02 -1.28520619e+00 1.28618052e+00 -1.60972274 0.47623933 540.00 -1.90400241e-01 -1.29118350e+00 1.30514638e+00 -1.71720301 0.47283191 540.25 -4.52244517e-01 -1.34189729e+00 1.41605559e+00 -1.89586006 0.58299801 540.50 -7.17480248e-01 -1.40871017e+00 1.58089919e+00 -2.04186984 0.66081717 540.75 -5.85084968e-01 -1.17671940e+00 1.31415104e+00 -2.03221511 0.59593211 541.00 -7.59006774e-01 -9.53038421e-01 1.21834868e+00 -2.24334277 0.65159809 541.25 -7.64049157e-01 -8.78314274e-01 1.16413362e+00 -2.28673283 0.59691367 541.50 -6.52875416e-01 -4.86760675e-01 8.14360033e-01 -2.50093637 0.38981192 541.75 -4.76307202e-01 -4.06528682e-01 6.26206132e-01 -2.43506958 0.25982303 542.00 -3.54702901e-01 -3.71935098e-01 5.13955120e-01 -2.33248397 0.18695119 542.25 -6.13567027e-02 -4.41708023e-01 4.45949125e-01 -1.70882093 0.13680827 542.50 1.45593724e-01 -6.37628398e-01 6.54039377e-01 -1.34630860 0.22166551 542.75 2.95606218e-01 -8.31924845e-01 8.82882769e-01 -1.22938284 0.11499128 543.00 -4.18389075e-02 -1.17628596e-01 1.24847830e-01 -1.91252809 0.00087776 543.25 -1.07261707e+00 7.19577255e-01 1.29162642e+00 2.55069171 0.24076364 543.50 -1.16726679e+00 4.01959775e-01 1.23453774e+00 2.80995131 0.40653011 543.75 -1.31792215e+00 1.06779685e-01 1.32224078e+00 3.06074801 0.54950262 544.00 -1.44005959e+00 2.88037563e-01 1.46858342e+00 2.94417997 0.62065318 544.25 -1.12342704e+00 4.47748627e-01 1.20936642e+00 2.76233169 0.64150133 544.50 -1.10496012e+00 6.53917615e-01 1.28395682e+00 2.60722290 0.72782554 544.75 -9.63606678e-01 8.31403703e-01 1.27270183e+00 2.42971201 0.78604782 545.00 -7.43677080e-01 7.83652255e-01 1.08035478e+00 2.33002721 0.77999427 545.25 -7.17547465e-01 5.65331642e-01 9.13495610e-01 2.47429407 0.78402370 545.50 -7.91442170e-01 5.05008219e-01 9.38836520e-01 2.57363843 0.81554472 545.75 -8.73645466e-01 3.09958317e-01 9.27000841e-01 2.80065936 0.67756810 546.00 -9.30342158e-01 2.45907773e-01 9.62292660e-01 2.88318268 0.67618273 546.25 -1.14175176e+00 4.42535295e-01 1.22451401e+00 2.77182728 0.77375532 546.50 -1.16758429e+00 7.14212565e-01 1.36870474e+00 2.59261382 0.77156342 546.75 -9.00555220e-01 9.32441372e-01 1.29632041e+00 2.33880060 0.84736654 547.00 -7.40508553e-01 9.86281193e-01 1.23333025e+00 2.21481484 0.81034404 547.25 -5.46500187e-01 9.84780545e-01 1.12625715e+00 2.07742904 0.74510403 547.50 -5.06868705e-01 8.34413940e-01 9.76300418e-01 2.11667923 0.62782443 547.75 -4.69089864e-01 7.41275734e-01 8.77231449e-01 2.13499517 0.57828561 548.00 -6.03567129e-01 8.28676680e-01 1.02518209e+00 2.20029722 0.58738659 548.25 -7.18896077e-01 1.23890170e+00 1.43237181e+00 2.09658128 0.48740122 548.50 -4.44136959e-01 1.79075024e+00 1.84500517e+00 1.81390801 0.50691101 548.75 1.52093659e-01 1.92646507e+00 1.93245961e+00 1.49201014 0.55868629 549.00 6.61470132e-01 1.60284567e+00 1.73397145e+00 1.17940278 0.51317050 549.25 1.17337721e+00 1.15872816e+00 1.64908005e+00 0.77911677 0.59722359 549.50 1.20596155e+00 8.66702994e-01 1.48509843e+00 0.62315456 0.63470448 549.75 1.26528125e+00 7.14466902e-01 1.45306558e+00 0.51403668 0.72087097 550.00 1.24007532e+00 5.79753856e-01 1.36890516e+00 0.43732358 0.68561281 550.25 1.09013985e+00 5.55903466e-01 1.22369668e+00 0.47156617 0.67328032 550.50 9.89495277e-01 6.29222924e-01 1.17261349e+00 0.56640122 0.63998941 550.75 9.88545449e-01 7.06475995e-01 1.21504339e+00 0.62049869 0.74207751 551.00 9.81642926e-01 6.42014372e-01 1.17294727e+00 0.57919623 0.70357897 551.25 9.54976040e-01 6.37196343e-01 1.14804112e+00 0.58839807 0.69675166 551.50 1.00524307e+00 7.25970167e-01 1.23997835e+00 0.62545973 0.67027467 551.75 1.12174010e+00 8.13618688e-01 1.38574031e+00 0.62751684 0.75164904 552.00 1.30707007e+00 8.26423270e-01 1.54641766e+00 0.56381124 0.74124498 552.25 1.75765702e+00 8.81013278e-01 1.96609832e+00 0.46464151 0.81877539 552.50 2.08789275e+00 6.19837312e-01 2.17795648e+00 0.28858479 0.81210665 552.75 2.21429251e+00 4.92016531e-01 2.26829706e+00 0.21864809 0.85130197 553.00 2.28251285e+00 3.68441213e-01 2.31205836e+00 0.16003865 0.81820538 553.25 2.51634580e+00 9.37519951e-02 2.51809167e+00 0.03723997 0.85192698 553.50 2.36684902e+00 -1.61325341e-01 2.37234065e+00 -0.06805512 0.88648244 553.75 2.18164088e+00 -3.18440796e-01 2.20475882e+00 -0.14494034 0.87891363 554.00 2.31487682e+00 -3.69371065e-01 2.34416077e+00 -0.15823014 0.82611814 554.25 2.41396975e+00 -4.17667519e-01 2.44983594e+00 -0.17132485 0.84595715 554.50 2.42409697e+00 -4.19128145e-01 2.46006393e+00 -0.17120806 0.88933195 554.75 2.44835796e+00 -6.12256931e-01 2.52375023e+00 -0.24504303 0.88890465 555.00 2.48109326e+00 -9.95003642e-01 2.67317340e+00 -0.38139775 0.86956955 555.25 2.44205763e+00 -1.19398913e+00 2.71831851e+00 -0.45475044 0.83487946 555.50 2.33727296e+00 -1.25000194e+00 2.65053764e+00 -0.49110794 0.80205308 555.75 2.43068262e+00 -1.40024241e+00 2.80515540e+00 -0.52263776 0.82849088 556.00 2.61378298e+00 -1.45538503e+00 2.99165624e+00 -0.50805790 0.88056400 556.25 2.72140961e+00 -1.45838319e+00 3.08754786e+00 -0.49194769 0.89411428 556.50 2.61191609e+00 -1.74888778e+00 3.14336033e+00 -0.59001708 0.87711722 556.75 2.66472094e+00 -2.02355523e+00 3.34596973e+00 -0.64948196 0.87708133 557.00 2.56666608e+00 -2.93796807e+00 3.90120893e+00 -0.85274876 0.83245937 557.25 2.35913789e+00 -3.26225684e+00 4.02589757e+00 -0.94469440 0.81659790 557.50 1.46367664e+00 -3.63238879e+00 3.91619683e+00 -1.18774812 0.83717948 557.75 1.03068587e+00 -3.51020914e+00 3.65839877e+00 -1.28519818 0.84594754 558.00 6.32847034e-01 -3.42584865e+00 3.48381032e+00 -1.38812846 0.79894239 558.25 2.98912490e-01 -3.26326444e+00 3.27692592e+00 -1.47945201 0.78424365 558.50 1.96523794e-02 -2.98614639e+00 2.98621106e+00 -1.56421524 0.76535001 558.75 -1.10098592e-01 -2.73781114e+00 2.74002401e+00 -1.61098876 0.72068513 559.00 1.60774633e-01 -2.54612329e+00 2.55119428e+00 -1.50773518 0.70725891 559.25 2.57392688e-01 -2.57273843e+00 2.58558196e+00 -1.47108194 0.70603543 559.50 4.99069376e-01 -2.37075639e+00 2.42271668e+00 -1.36331514 0.69834632 559.75 5.53603571e-01 -2.45600966e+00 2.51762991e+00 -1.34909383 0.72573117 560.00 5.86057451e-01 -2.50530553e+00 2.57293978e+00 -1.34100189 0.78337126 560.25 7.45002235e-01 -2.65741829e+00 2.75987324e+00 -1.29746484 0.76189078 560.50 8.54481640e-01 -3.29012568e+00 3.39927432e+00 -1.31669904 0.77512101 560.75 8.75905734e-01 -3.13737233e+00 3.25734800e+00 -1.29854399 0.74437039 561.00 8.46009135e-01 -3.12424625e+00 3.23676476e+00 -1.30634996 0.78418797 561.25 8.02577986e-01 -3.42185386e+00 3.51471410e+00 -1.34041580 0.77726926 561.50 9.66859594e-01 -3.91965924e+00 4.03714578e+00 -1.32895489 0.77926276 561.75 5.26527476e-01 -3.92458332e+00 3.95974562e+00 -1.43743131 0.73235817 562.00 9.02972840e-02 -4.66024579e+00 4.66112051e+00 -1.55142267 0.63223561 562.25 7.25860246e-01 -4.92864033e+00 4.98180375e+00 -1.42457352 0.47031600 562.50 -5.48964440e-02 -4.26508670e+00 4.26543998e+00 -1.58366674 0.24805971 562.75 -1.60399175e+00 -1.99014516e+00 2.55606481e+00 -2.24916524 0.10934922 563.00 -2.33451489e+00 1.62122926e-01 2.34013752e+00 3.07225788 0.11379883 563.25 -1.97655624e+00 1.34458574e+00 2.39054081e+00 2.54423353 0.22699298 563.50 -2.18765923e+00 2.04895956e+00 2.99734686e+00 2.38892109 0.42527335 563.75 -1.55143626e+00 1.49536407e+00 2.15477799e+00 2.37459605 0.33376171 564.00 -9.69755048e-01 1.35669715e+00 1.66764865e+00 2.19138038 0.33608612 564.25 -7.67026416e-01 6.30752646e-01 9.93065166e-01 2.45338042 0.23584773 564.50 -7.37621935e-01 2.11345069e-01 7.67302325e-01 2.86254620 0.24920606 564.75 -9.06483649e-01 -2.20518669e-01 9.32920730e-01 -2.90295974 0.30339293 565.00 -1.06078965e+00 -2.90142364e-01 1.09975328e+00 -2.87460714 0.41363565 565.25 -1.20301042e+00 -1.95273927e-01 1.21875591e+00 -2.98067509 0.37727767 565.50 -1.40165596e+00 2.89691900e-03 1.40165896e+00 3.13952587 0.40919708 565.75 -1.43998009e+00 4.27831203e-01 1.50219247e+00 2.85279016 0.57088708 566.00 -1.00929854e+00 5.19475047e-01 1.13513782e+00 2.66626287 0.43922724 566.25 -2.80736618e-01 2.32803228e-01 3.64705898e-01 2.44926402 0.08649329 566.50 -6.92030810e-02 -8.25021118e-02 1.07683169e-01 -2.26875437 0.00875241 566.75 1.11444489e-01 -7.28889411e-01 7.37359917e-01 -1.41907503 0.29986162 567.00 1.72746432e-01 -9.68007984e-01 9.83300964e-01 -1.39419974 0.43925272 567.25 -2.43548912e-01 -1.57377161e+00 1.59250530e+00 -1.72433330 0.60943985 567.50 -5.52763441e-01 -1.74095951e+00 1.82660544e+00 -1.87823444 0.74573262 567.75 -1.18435939e+00 -2.03247860e+00 2.35237676e+00 -2.09841063 0.80802236 568.00 -1.49123011e+00 -2.02843190e+00 2.51759870e+00 -2.20473459 0.79131333 568.25 -1.78579912e+00 -1.42859118e+00 2.28690866e+00 -2.46686814 0.79078262 568.50 -1.88505246e+00 -1.22537461e+00 2.24832509e+00 -2.56518368 0.84401113 568.75 -2.01925348e+00 -8.75335374e-01 2.20081726e+00 -2.73254910 0.80243855 569.00 -1.99296582e+00 -4.98551757e-01 2.05437743e+00 -2.89646746 0.80441989 569.25 -1.67872117e+00 -3.50891909e-01 1.71500143e+00 -2.93553605 0.80857852 569.50 -1.48131090e+00 -3.24819438e-01 1.51650573e+00 -2.92573077 0.74844547 569.75 -1.40207243e+00 -2.43336318e-01 1.42303185e+00 -2.96974964 0.76693017 570.00 -1.37490185e+00 -5.88164079e-02 1.37615932e+00 -3.09884010 0.75996665 570.25 -1.46478232e+00 -5.97231302e-02 1.46599935e+00 -3.10084252 0.79715326 570.50 -1.42587866e+00 1.16925726e-01 1.43066473e+00 3.05977314 0.77730302 570.75 -1.15483286e+00 1.96960087e-01 1.17150851e+00 2.97266518 0.62545692 571.00 -6.61942888e-01 1.96102682e-01 6.90380076e-01 2.85357685 0.36325213 571.25 -1.61402738e-01 1.73634813e-01 2.37065165e-01 2.31970114 0.08576974 571.50 -3.63329070e-03 -3.28643535e-03 4.89912835e-03 -2.40627816 0.00003218 571.75 2.35780350e-01 -4.43644944e-01 5.02407415e-01 -1.08229719 0.27226498 572.00 3.84815886e-01 -7.17070564e-01 8.13801855e-01 -1.07826041 0.51084840 572.25 7.15606483e-01 -1.07753179e+00 1.29350972e+00 -0.98456140 0.69966389 572.50 7.06825208e-01 -1.41534805e+00 1.58202781e+00 -1.10762861 0.73732560 572.75 7.30817612e-01 -1.90890052e+00 2.04401457e+00 -1.20516355 0.81293232 573.00 5.68293520e-01 -2.44740630e+00 2.51251968e+00 -1.34263724 0.79502717 573.25 9.94721369e-02 -3.14658527e+00 3.14815717e+00 -1.53919413 0.77087134 573.50 -3.80066180e-01 -3.32908487e+00 3.35070983e+00 -1.68446953 0.75103827 573.75 -6.52138111e-01 -3.42378319e+00 3.48533721e+00 -1.75901471 0.78438953 574.00 -1.46245275e+00 -3.83537378e+00 4.10473630e+00 -1.93508444 0.82666697 574.25 -2.12181041e+00 -4.33629530e+00 4.82758080e+00 -2.02585873 0.85539469 574.50 -2.99000294e+00 -3.87957281e+00 4.89808155e+00 -2.22741696 0.81027666 574.75 -3.50171122e+00 -3.61692838e+00 5.03429761e+00 -2.34001063 0.82906718 575.00 -4.23317854e+00 -3.08403015e+00 5.23746528e+00 -2.51196951 0.82804896 575.25 -4.78205664e+00 -2.48317740e+00 5.38834258e+00 -2.66264834 0.84523764 575.50 -5.57013296e+00 -1.71852726e+00 5.82921239e+00 -2.84233290 0.78961715 575.75 -5.77236664e+00 -9.87714085e-01 5.85626125e+00 -2.97212313 0.78804791 576.00 -4.75491869e+00 5.54355321e-01 4.78712456e+00 3.02553095 0.69948365 576.25 -4.35229460e+00 1.04583410e+00 4.47618557e+00 2.90576887 0.73546631 576.50 -4.08563549e+00 5.96179575e-01 4.12890391e+00 2.99669442 0.67673049 576.75 -3.37670395e+00 2.13740367e-01 3.38346191e+00 3.07837847 0.51673100 577.00 -1.86096486e+00 -9.18839092e-01 2.07544103e+00 -2.68296285 0.22834461 577.25 -1.27378248e+00 -1.46400960e+00 1.94057876e+00 -2.28682404 0.19291368 577.50 8.73156671e-02 -3.23870184e+00 3.23987865e+00 -1.54384277 0.26698941 577.75 1.03755770e+00 -3.78264883e+00 3.92236640e+00 -1.30308664 0.27237441 578.00 3.19055727e+00 -4.64763532e+00 5.63739033e+00 -0.96919483 0.34525222 578.25 4.29269362e+00 -4.55328185e+00 6.25776271e+00 -0.81484804 0.45144465 578.50 7.30051996e+00 -2.14332859e+00 7.60864305e+00 -0.28556182 0.51320340 578.75 7.20073185e+00 -1.71293917e+00 7.40166872e+00 -0.23354330 0.55478914 579.00 5.38096079e+00 -2.28798174e+00 5.84718732e+00 -0.40203960 0.48070699 579.25 4.43497650e+00 -2.18481405e+00 4.94392850e+00 -0.45773635 0.42247142 579.50 3.54133135e+00 -3.19517925e+00 4.76971678e+00 -0.73405883 0.42648250 579.75 3.17321797e+00 -3.74797899e+00 4.91087149e+00 -0.86825164 0.45652033 580.00 2.45606914e+00 -3.84183762e+00 4.55982367e+00 -1.00198315 0.54805858 580.25 1.39466015e+00 -3.68964373e+00 3.94443250e+00 -1.20940409 0.47395858 580.50 6.49664074e-02 -2.55446860e+00 2.55529460e+00 -1.54536935 0.36416662 580.75 -3.27776815e-01 -2.68989172e+00 2.70978876e+00 -1.69205354 0.43981371 581.00 -1.67867614e+00 -1.72510435e+00 2.40706016e+00 -2.34255515 0.38906781 581.25 -2.11731129e+00 -7.26808263e-01 2.23858378e+00 -2.81092642 0.40043091 581.50 -2.07985680e+00 2.29039060e-01 2.09242998e+00 3.03191208 0.44682873 581.75 -1.54022288e+00 7.50798202e-01 1.71347146e+00 2.68802667 0.38660260 582.00 -8.17466385e-01 1.62937616e+00 1.82294211e+00 2.03580711 0.37957322 582.25 -4.75862638e-01 2.21526457e+00 2.26579839e+00 1.78239159 0.48322389 582.50 9.59095442e-02 2.26640074e+00 2.26842918e+00 1.52850356 0.52573440 582.75 1.08112856e+00 2.27831851e+00 2.52181962e+00 1.12773223 0.63082338 583.00 1.76043151e+00 2.14468730e+00 2.77467165e+00 0.88348040 0.70412912 583.25 2.54372260e+00 1.10720281e+00 2.77424273e+00 0.41053607 0.54250757 583.50 2.93266385e+00 2.68186836e-01 2.94490092e+00 0.09119455 0.58587859 583.75 2.65882240e+00 -1.22196397e-01 2.66162892e+00 -0.04592652 0.42791328 584.00 1.59581943e+00 -4.86025982e-01 1.66819091e+00 -0.29563686 0.19553180 584.25 1.60361889e+00 4.17992147e-01 1.65719974e+00 0.25498199 0.21442088 584.50 1.90457318e+00 5.88188791e-01 1.99333014e+00 0.29953764 0.24345682 584.75 3.26145498e+00 6.15473664e-01 3.31902040e+00 0.18651793 0.46315907 585.00 3.83806349e+00 1.04971705e+00 3.97902466e+00 0.26697276 0.54629684 585.25 4.74517027e+00 2.02420559e+00 5.15888061e+00 0.40321010 0.48463173 585.50 6.34242888e+00 1.39635151e+00 6.49432072e+00 0.21670327 0.50282314 585.75 8.05846053e+00 -1.19455063e+00 8.14651689e+00 -0.14716392 0.55949774 586.00 9.55767918e+00 -2.25463106e+00 9.82000980e+00 -0.23166216 0.63191166 586.25 1.11708404e+01 -6.32828679e+00 1.28388040e+01 -0.51542323 0.58407912 586.50 1.06779794e+01 -1.08568959e+01 1.52279819e+01 -0.79370619 0.65571750 586.75 -2.11494697e-01 -1.64303855e+01 1.64317466e+01 -1.58366778 0.59927849 587.00 -4.84499147e+00 -1.80415469e+01 1.86807751e+01 -1.83315278 0.63114532 587.25 -1.39055039e+01 -9.77258753e+00 1.69960732e+01 -2.52899962 0.49709371 587.50 -1.80914176e+01 -4.02464471e+00 1.85336762e+01 -2.92269566 0.60497220 587.75 -1.07519421e+01 4.91349262e+00 1.18214495e+01 2.71294395 0.46154545 588.00 -6.77844717e+00 7.64032934e+00 1.02138131e+01 2.29649054 0.48049286 588.25 1.35713134e+00 8.01519322e+00 8.12927597e+00 1.40306729 0.40611937 588.50 2.92724014e+00 4.95164764e+00 5.75217778e+00 1.03689857 0.26084848 588.75 2.80417077e+00 -2.41045903e-01 2.81451183e+00 -0.08574899 0.12213780 589.00 3.65665967e+00 -1.37997697e+00 3.90838795e+00 -0.36086201 0.25455544 589.25 3.14346282e+00 -4.00821141e+00 5.09383129e+00 -0.90572954 0.49233015 589.50 2.75577101e+00 -4.63460173e+00 5.39201327e+00 -1.03435101 0.55864491 589.75 1.50008729e+00 -4.56626568e+00 4.80635455e+00 -1.25338842 0.49075145 590.00 1.02977947e+00 -5.18632939e+00 5.28757585e+00 -1.37478912 0.55779734 590.25 9.56190380e-01 -5.70798790e+00 5.78752330e+00 -1.40481950 0.53899191 590.50 -7.48853700e-03 -5.68101043e+00 5.68101537e+00 -1.57211450 0.58866864 590.75 -1.22873652e+00 -5.63697735e+00 5.76934200e+00 -1.78541707 0.61069939 591.00 -1.31213246e+00 -5.10594977e+00 5.27185116e+00 -1.82233454 0.62625211 591.25 -1.02694356e+00 -4.45733988e+00 4.57411105e+00 -1.79723872 0.61519075 591.50 -1.24831073e+00 -4.12491237e+00 4.30966144e+00 -1.86466166 0.63101854 591.75 -1.63445055e+00 -3.96329603e+00 4.28709039e+00 -1.96194370 0.59346478 592.00 -1.86294885e+00 -4.49587041e+00 4.86656236e+00 -1.96362798 0.65585754 592.25 -2.09947348e+00 -5.04332978e+00 5.46287142e+00 -1.96526404 0.71677189 592.50 -1.70903571e+00 -5.08455366e+00 5.36409255e+00 -1.89505553 0.61791923 592.75 -1.43581213e+00 -5.78000607e+00 5.95567180e+00 -1.81427809 0.62099421 593.00 -2.60232731e+00 -7.26187152e+00 7.71407061e+00 -1.91489480 0.68705744 593.25 -3.67724275e+00 -7.84356818e+00 8.66277531e+00 -2.00919248 0.76702849 593.50 -4.73255251e+00 -8.17454246e+00 9.44564438e+00 -2.09558501 0.75838083 593.75 -6.56629967e+00 -8.35249041e+00 1.06245182e+01 -2.23703412 0.75075647 594.00 -7.83185033e+00 -7.52777302e+00 1.08630220e+01 -2.37598909 0.64812322 594.25 -1.13810481e+01 -7.42321267e+00 1.35879484e+01 -2.56364202 0.78331007 594.50 -1.27842329e+01 -5.06588097e+00 1.37513549e+01 -2.76431451 0.74497536 594.75 -1.40038184e+01 -2.59765802e+00 1.42427089e+01 -2.95818095 0.73847464 595.00 -1.28503403e+01 4.42953607e-01 1.28579724e+01 3.10713611 0.72578904 595.25 -1.23036299e+01 2.08308374e+00 1.24787237e+01 2.97387666 0.77128585 595.50 -9.68313846e+00 2.86343210e+00 1.00976440e+01 2.85407331 0.77911613 595.75 -9.11819440e+00 2.58553388e+00 9.47768192e+00 2.86528799 0.79123812 596.00 -9.83015480e+00 3.23269279e+00 1.03480552e+01 2.82387825 0.81686066 596.25 -1.12459726e+01 4.40237277e+00 1.20769527e+01 2.76846808 0.86321041 596.50 -1.25218655e+01 4.75001763e+00 1.33925271e+01 2.77902436 0.86817382 596.75 -1.29332005e+01 5.32934304e+00 1.39881940e+01 2.75072730 0.83780267 597.00 -1.15038868e+01 8.48465618e+00 1.42943626e+01 2.50610928 0.81426676 597.25 -1.05869265e+01 1.05486862e+01 1.49451595e+01 2.35800377 0.85351899 597.50 -9.05230987e+00 1.12186923e+01 1.44153866e+01 2.24972759 0.86353946 597.75 -7.69225827e+00 1.25602167e+01 1.47285397e+01 2.12030571 0.86326570 598.00 -5.41026867e+00 1.39853270e+01 1.49953452e+01 1.93991815 0.90125850 598.25 -4.69809964e+00 1.43657644e+01 1.51144741e+01 1.88686720 0.89058637 598.50 -1.43623105e+00 1.47358449e+01 1.48056707e+01 1.66795458 0.81822147 598.75 1.45990259e+00 1.40168990e+01 1.40927206e+01 1.46701747 0.80153219 599.00 3.50123511e+00 1.15732385e+01 1.20912570e+01 1.27702137 0.81453159 599.25 5.18252832e+00 1.01223912e+01 1.13719569e+01 1.09760551 0.75697844 599.50 6.89462426e+00 7.29913905e+00 1.00405814e+01 0.81388993 0.74164959 599.75 5.92575924e+00 5.85247615e+00 8.32863132e+00 0.77917634 0.70375029 600.00 5.52971366e+00 3.92588871e+00 6.78161746e+00 0.61738088 0.80903078 600.25 5.03411557e+00 3.19328219e+00 5.96149065e+00 0.56527923 0.82666410 600.50 3.84973893e+00 2.94159718e+00 4.84494415e+00 0.65246612 0.82555180 600.75 3.63231225e+00 2.96872631e+00 4.69116491e+00 0.68520725 0.81904840 601.00 3.93538638e+00 2.85724402e+00 4.86324062e+00 0.62798889 0.87305260 601.25 4.14478409e+00 2.62622201e+00 4.90675831e+00 0.56477464 0.83198848 601.50 4.50183723e+00 2.23963473e+00 5.02817086e+00 0.46164039 0.77475732 601.75 4.28555246e+00 1.65167017e+00 4.59281768e+00 0.36786087 0.72126234 602.00 3.81179988e+00 -2.40024752e-01 3.81934945e+00 -0.06288585 0.63361920 602.25 2.71791132e+00 -1.43262948e+00 3.07237192e+00 -0.48509714 0.57527546 602.50 1.39151438e+00 -1.89545610e+00 2.35139663e+00 -0.93752853 0.58708539 602.75 1.41043978e-01 -1.55000456e+00 1.55640854e+00 -1.48005039 0.34407913 603.00 -7.19419345e-01 -8.68191829e-01 1.12752882e+00 -2.26275896 0.27862737 603.25 -1.11090134e+00 1.33291415e-01 1.11886924e+00 3.02217859 0.30429357 603.50 -1.07306673e+00 7.91232332e-01 1.33323697e+00 2.50623285 0.54161079 603.75 -9.10574909e-01 1.10195999e+00 1.42949728e+00 2.26138308 0.58052122 604.00 -7.17020054e-01 1.54474410e+00 1.70304201e+00 2.00536931 0.64872012 604.25 -8.09082313e-01 1.71921895e+00 1.90008631e+00 2.01065705 0.72843734 604.50 -5.30889256e-01 1.87461394e+00 1.94833796e+00 1.84676922 0.69798249 604.75 -7.00247079e-01 2.12617048e+00 2.23851443e+00 1.88895457 0.72955198 605.00 -7.68529362e-01 2.29562374e+00 2.42085227e+00 1.89384849 0.76366547 605.25 -4.94660999e-01 2.23596890e+00 2.29003197e+00 1.78851852 0.56779427 605.50 -4.57681820e-03 2.21382124e+00 2.21382598e+00 1.57286371 0.52743211 605.75 2.23434958e-01 2.10767070e+00 2.11948082e+00 1.46518042 0.34977500 606.00 6.64363913e-01 2.20281351e+00 2.30081871e+00 1.27787422 0.28788685 606.25 3.87846354e-01 7.24329203e-01 8.21631054e-01 1.07918793 0.04180601 606.50 -2.63448259e-01 -2.56839918e-01 3.67928972e-01 -2.36889512 0.01032878 606.75 1.46152627e-01 -5.03789356e-01 5.24561060e-01 -1.28844056 0.02232849 607.00 5.64609183e-01 -7.05967889e-01 9.03976874e-01 -0.89619802 0.06956859 607.25 -3.17113455e-01 -1.30843595e+00 1.34631556e+00 -1.80857224 0.19655278 607.50 -2.98065385e-01 -1.36447156e+00 1.39664799e+00 -1.78586531 0.22741834 607.75 -6.33320488e-01 -1.64178849e+00 1.75970574e+00 -1.93895849 0.35195320 608.00 -7.13349456e-01 -1.98381450e+00 2.10817158e+00 -1.91598426 0.48000320 608.25 -6.64972075e-01 -1.78028609e+00 1.90042270e+00 -1.92826864 0.48871382 608.50 -6.31989408e-01 -1.87291045e+00 1.97666490e+00 -1.89623568 0.53027948 608.75 -1.82556503e-01 -1.96853623e+00 1.97698300e+00 -1.66326902 0.49943385 609.00 1.69275473e-01 -2.28677444e+00 2.29303108e+00 -1.49690740 0.50740508 609.25 1.84534949e+00 -2.91240408e+00 3.44781268e+00 -1.00602431 0.35440464 609.50 4.41306177e+00 -2.63168036e+00 5.13817630e+00 -0.53772316 0.41777300 609.75 5.48495816e+00 1.17103836e+00 5.60857351e+00 0.21034196 0.47981931 610.00 4.97475539e+00 1.88177080e+00 5.31876419e+00 0.36162917 0.56524652 610.25 4.03521603e+00 1.50669383e+00 4.30733035e+00 0.35735505 0.59391049 610.50 3.47972514e+00 2.05827911e+00 4.04289500e+00 0.53415067 0.68699419 610.75 3.42452033e+00 1.88796892e+00 3.91046879e+00 0.50384766 0.81033593 611.00 3.07345866e+00 1.11954864e+00 3.27101472e+00 0.34932474 0.74222239 611.25 2.71230748e+00 6.09020553e-01 2.77984135e+00 0.22087622 0.72621876 611.50 2.39898551e+00 3.89436634e-01 2.43038935e+00 0.16093006 0.69208416 611.75 1.99693505e+00 1.77544879e-02 1.99701397e+00 0.00889063 0.71647429 612.00 1.74408135e+00 -2.02911576e-01 1.75584534e+00 -0.11582225 0.62682316 612.25 1.27042353e+00 -5.14498227e-01 1.37065108e+00 -0.38479352 0.42654791 612.50 8.74259959e-01 -6.43672116e-01 1.08565384e+00 -0.63464156 0.32664346 612.75 4.24357205e-01 -5.24078803e-01 6.74342368e-01 -0.89015646 0.17909369 613.00 -3.05179384e-02 -1.78715266e-01 1.81302208e-01 -1.73992787 0.01350320 613.25 -2.66064410e-01 1.59138110e-02 2.66539902e-01 3.08185195 0.02419322 613.50 -1.48396372e-01 1.74072243e-01 2.28741402e-01 2.27673926 0.01488323 613.75 -2.61256182e-01 7.76425994e-01 8.19202122e-01 1.89538125 0.15899094 614.00 6.00868858e-02 5.99707861e-01 6.02710505e-01 1.47093600 0.10510796 614.25 4.75227250e-01 4.56549568e-01 6.58998063e-01 0.76535562 0.13585988 614.50 5.25618519e-01 8.21668398e-02 5.32002084e-01 0.15506907 0.20080246 614.75 5.24718954e-01 2.48534568e-02 5.25307220e-01 0.04732990 0.20636984 615.00 3.74636186e-01 -2.14901024e-02 3.75252044e-01 -0.05729980 0.17120539 615.25 2.87788558e-01 -1.05393210e-02 2.87981477e-01 -0.03660539 0.12083054 615.50 2.38520585e-01 1.57328500e-02 2.39038892e-01 0.06586473 0.11873501 615.75 2.17097487e-01 5.56988640e-02 2.24128718e-01 0.25114463 0.08808326 616.00 4.72310367e-02 3.84222115e-02 6.08854429e-02 0.68291559 0.00924106 616.25 -3.92734824e-02 -7.19109681e-02 8.19365227e-02 -2.07067146 0.01507551 616.50 7.22970511e-02 -1.16303181e-01 1.36942665e-01 -1.01462712 0.05329922 616.75 1.59946234e-01 -2.08441258e-01 2.62736666e-01 -0.91628689 0.17712456 617.00 1.17010519e-01 -1.68263266e-01 2.04948745e-01 -0.96316331 0.14823340 617.25 3.12052201e-02 -2.09131193e-01 2.11446498e-01 -1.42267555 0.12536988 617.50 -4.20675976e-03 -3.83476905e-01 3.83499979e-01 -1.58176593 0.28149766 617.75 1.69789103e-02 -4.10799811e-01 4.11150542e-01 -1.52948849 0.26839366 618.00 -1.01430373e-01 -4.64210520e-01 4.75162632e-01 -1.78591620 0.31230630 618.25 3.87944424e-02 -5.66185189e-01 5.67512711e-01 -1.50238426 0.33972191 618.50 -3.18020431e-01 -7.95564148e-01 8.56772612e-01 -1.95108030 0.54990003 618.75 -4.47912935e-01 -9.40344582e-01 1.04157282e+00 -2.01532805 0.64108728 619.00 -7.04176669e-01 -9.20662415e-01 1.15908760e+00 -2.22373939 0.66617876 619.25 -7.12910747e-01 -8.89992257e-01 1.14031923e+00 -2.24616517 0.68647786 619.50 -7.44260694e-01 -9.89111806e-01 1.23784738e+00 -2.21586586 0.70413950 619.75 -9.19269381e-01 -1.21767943e+00 1.52571275e+00 -2.21744865 0.65673137 620.00 -1.05810788e+00 -1.79121357e+00 2.08039380e+00 -2.10436526 0.82711702 620.25 -1.52276791e+00 -1.90095062e+00 2.43565912e+00 -2.24618084 0.85586898 620.50 -2.44705834e+00 -1.64173102e+00 2.94675674e+00 -2.55066512 0.83147814 620.75 -2.77016765e+00 -1.27591349e+00 3.04988263e+00 -2.70996647 0.83135446 621.00 -3.18447605e+00 -8.23212860e-01 3.28915903e+00 -2.88862253 0.86749286 621.25 -3.41749631e+00 -5.23389840e-01 3.45734262e+00 -2.98962337 0.85450174 621.50 -3.42089155e+00 2.06849297e-01 3.42713957e+00 3.08119970 0.90209509 621.75 -3.52923285e+00 4.00210532e-01 3.55185205e+00 3.02867628 0.92396200 622.00 -3.78382394e+00 6.76522619e-01 3.84382706e+00 2.96466873 0.92797092 622.25 -3.78630353e+00 9.87234834e-01 3.91289242e+00 2.88653305 0.88111369 622.50 -3.82150847e+00 1.27284008e+00 4.02790875e+00 2.82007670 0.79293473 622.75 -3.77852615e+00 1.42277809e+00 4.03751871e+00 2.78146978 0.73726816 623.00 -3.69622175e+00 1.54771320e+00 4.00717748e+00 2.74504604 0.79094953 623.25 -3.65192495e+00 1.83502682e+00 4.08703795e+00 2.67596136 0.79963847 623.50 -3.29537034e+00 2.08048800e+00 3.89716512e+00 2.57844963 0.80404364 623.75 -3.14499850e+00 2.29940523e+00 3.89593121e+00 2.51027762 0.70218620 624.00 -3.15016138e+00 3.16739375e+00 4.46720269e+00 2.35346680 0.74781288 624.25 -3.12991378e+00 3.16985908e+00 4.45470166e+00 2.34985382 0.72277594 624.50 -2.68412007e+00 2.79254103e+00 3.87334300e+00 2.33640017 0.54643266 624.75 -2.34529419e+00 2.55839817e+00 3.47070685e+00 2.31276396 0.59794490 625.00 -1.72246372e+00 2.55720059e+00 3.08320549e+00 2.16356567 0.58770857 625.25 -1.16814753e+00 3.00243342e+00 3.22167272e+00 1.94184225 0.66432542 625.50 -2.80572196e-01 2.95125408e+00 2.96456092e+00 1.66558026 0.64654615 625.75 -2.09444004e-01 2.59277525e+00 2.60122093e+00 1.65140116 0.55212106 626.00 -5.29715815e-02 2.64288792e+00 2.64341872e+00 1.59083671 0.52244948 626.25 -1.56468939e-01 2.84920292e+00 2.85349607e+00 1.62565796 0.64796761 626.50 -3.90531602e-01 2.65259954e+00 2.68119363e+00 1.71697221 0.70304376 626.75 7.15715177e-02 2.46464739e+00 2.46568636e+00 1.54176523 0.82298525 627.00 2.78350184e-01 2.58704309e+00 2.60197440e+00 1.46361470 0.86764489 627.25 2.91118528e-01 2.47420556e+00 2.49127340e+00 1.45367342 0.84414334 627.50 1.71630969e-01 2.39118933e+00 2.39734095e+00 1.49914280 0.78133387 627.75 4.96623074e-01 2.04978951e+00 2.10909258e+00 1.33309661 0.77813470 628.00 6.08494853e-01 1.97211766e+00 2.06385902e+00 1.27151502 0.80157093 628.25 6.67162177e-01 1.80972656e+00 1.92878604e+00 1.21760122 0.79965969 628.50 7.32822320e-01 1.64374960e+00 1.79970589e+00 1.15142094 0.77109432 628.75 6.79939257e-01 1.51917661e+00 1.66439628e+00 1.14996427 0.75507045 629.00 6.66403341e-01 1.56332112e+00 1.69943118e+00 1.16784698 0.78373564 629.25 3.58233195e-01 1.37887015e+00 1.42464519e+00 1.31661376 0.61708388 629.50 3.38184755e-01 1.37877293e+00 1.41964211e+00 1.33026538 0.52028707 629.75 -7.83590506e-02 1.14163698e+00 1.14432300e+00 1.63932629 0.33663843 630.00 1.25581706e-01 8.26280898e-01 8.35769638e-01 1.41996633 0.27623858 630.25 3.75969512e-01 1.21795867e+00 1.27466717e+00 1.27138786 0.46010126 630.50 1.11612751e-01 1.13076370e+00 1.13625875e+00 1.47240939 0.36448641 630.75 2.86749883e-01 8.79307582e-01 9.24882327e-01 1.25556194 0.29859622 631.00 5.70515594e-02 8.53901276e-01 8.55805042e-01 1.50408265 0.24505577 631.25 -1.66424729e-01 6.90087818e-01 7.09872092e-01 1.80744216 0.20228394 631.50 -7.74994095e-02 8.21402613e-01 8.25050550e-01 1.66486794 0.27609003 631.75 -2.92729780e-01 7.68301568e-01 8.22178827e-01 1.93482469 0.29549341 632.00 -4.98426758e-01 7.05657389e-01 8.63933784e-01 2.18575778 0.35561942 632.25 -7.66051721e-01 6.66966581e-01 1.01571633e+00 2.42522898 0.39343100 632.50 -9.21371225e-01 5.04009309e-01 1.05021441e+00 2.64103954 0.36039866 632.75 -9.66795599e-01 3.43931949e-01 1.02614956e+00 2.79980968 0.26856964 633.00 -1.12778655e+00 4.95469487e-01 1.23182487e+00 2.72764797 0.35760418 633.25 -1.23922818e+00 6.80061374e-01 1.41356639e+00 2.63968799 0.57621918 633.50 -1.26093088e+00 5.62750061e-01 1.38080930e+00 2.72182215 0.56082200 633.75 -1.30065367e+00 2.42469606e-01 1.32306140e+00 2.95728693 0.49812917 634.00 -1.39340115e+00 1.76799652e-01 1.40457285e+00 3.01538354 0.52135858 634.25 -1.79500266e+00 1.00215231e-01 1.79779800e+00 3.08582042 0.55100437 634.50 -2.08062077e+00 -1.35709865e-01 2.08504195e+00 -3.07645926 0.57485548 634.75 -2.45210916e+00 -4.29091093e-01 2.48936910e+00 -2.96835807 0.56981491 635.00 -3.24984596e+00 -4.06745307e-01 3.27520083e+00 -3.01708176 0.56893538 635.25 -4.63772890e+00 -7.62551054e-01 4.70000143e+00 -2.97862743 0.60042050 635.50 -5.08618227e+00 -7.35339968e-02 5.08671380e+00 -3.12713606 0.49356774 635.75 -5.04460373e+00 1.05671503e+00 5.15409288e+00 2.93510397 0.38820635 636.00 -5.52471787e+00 1.79302968e+00 5.80839590e+00 2.82777068 0.41863907 636.25 -7.03613187e+00 2.01460978e+00 7.31886632e+00 2.86272987 0.44065636 636.50 -7.11420202e+00 2.22746986e+00 7.45476306e+00 2.83815957 0.42898341 636.75 -7.08015171e+00 3.42977983e+00 7.86714293e+00 2.69048509 0.48046287 637.00 -5.85232484e+00 4.17382907e+00 7.18822337e+00 2.52206801 0.25708939 637.25 -6.07806003e-01 1.19991173e+00 1.34507111e+00 2.03966404 0.00790745 637.50 6.77245117e+00 -6.96631754e-01 6.80818556e+00 -0.10250207 0.23969271 637.75 9.11558002e+00 1.64743978e+00 9.26325304e+00 0.17879792 0.46759908 638.00 9.09246959e+00 1.54794582e+00 9.22329331e+00 0.16862809 0.52729291 638.25 9.24824008e+00 7.72695654e-01 9.28046352e+00 0.08335696 0.66009460 638.50 8.26071673e+00 1.73333086e+00 8.44060879e+00 0.20682759 0.81346098 638.75 8.18504404e+00 1.51197137e+00 8.32352109e+00 0.18266457 0.85207697 639.00 7.62350917e+00 1.09166896e+00 7.70127478e+00 0.14223078 0.87770191 639.25 7.26228997e+00 1.12132805e+00 7.34834894e+00 0.15319442 0.87829725 639.50 6.48520062e+00 8.63139581e-01 6.54238771e+00 0.13231611 0.87832657 639.75 5.96774412e+00 6.22745842e-01 6.00014852e+00 0.10397565 0.90067683 640.00 5.48038994e+00 1.66027610e-01 5.48290426e+00 0.03028559 0.91329541 640.25 5.34017332e+00 1.51682869e-01 5.34232709e+00 0.02839647 0.89466076 640.50 4.58051814e+00 9.57088538e-01 4.67944066e+00 0.20598409 0.80816217 640.75 4.27958263e+00 1.13416668e+00 4.42731991e+00 0.25906260 0.82585068 641.00 3.84446302e+00 1.21513607e+00 4.03192902e+00 0.30613787 0.81372150 641.25 3.75972273e+00 1.35058229e+00 3.99494525e+00 0.34486836 0.75113599 641.50 3.48015041e+00 2.43522223e+00 4.24755861e+00 0.61055565 0.72499963 641.75 3.32075025e+00 2.78661588e+00 4.33504444e+00 0.69816273 0.70248539 642.00 3.94828419e+00 2.25169198e+00 4.54522439e+00 0.51829216 0.75505190 642.25 4.17540111e+00 3.03334012e+00 5.16092304e+00 0.62827678 0.78908070 642.50 4.65382957e+00 3.47173306e+00 5.80612264e+00 0.64093291 0.78602329 642.75 4.82356870e+00 2.83803916e+00 5.59654191e+00 0.53182353 0.77354662 643.00 5.29272459e+00 2.03213431e+00 5.66943590e+00 0.36659286 0.78160451 643.25 5.19416707e+00 1.80017312e+00 5.49727158e+00 0.33362114 0.77938655 643.50 4.67478143e+00 1.48791003e+00 4.90585952e+00 0.30814594 0.65521030 643.75 4.73889233e+00 1.75767977e+00 5.05435838e+00 0.35517588 0.65710966 644.00 4.03700804e+00 2.57245200e+00 4.78695552e+00 0.56733670 0.57045624 644.25 3.11323772e+00 2.39661280e+00 3.92886777e+00 0.65606170 0.50166673 644.50 3.23171133e+00 3.16307712e+00 4.52205872e+00 0.77466574 0.50998621 644.75 4.97163929e+00 3.73170171e+00 6.21633292e+00 0.64388362 0.47671546 645.00 6.97033921e+00 3.06701974e+00 7.61526354e+00 0.41451535 0.43092266 645.25 5.74561699e+00 1.56137475e+00 5.95399074e+00 0.26534275 0.22975986 645.50 4.21278490e-01 2.73257300e-01 5.02140536e-01 0.57541726 0.00127146 645.75 9.32824606e-01 -2.09198602e-01 9.55994665e-01 -0.22061341 0.00650404 646.00 3.88527490e+00 3.94314902e-02 3.88547498e+00 0.01014861 0.08606183 646.25 1.88210796e+00 9.63455032e-01 2.11437366e+00 0.47312390 0.02050732 646.50 -1.10216645e+00 -5.30797909e-01 1.22332224e+00 -2.69277712 0.00398598 646.75 2.33433875e+00 -1.27576147e+00 2.66020765e+00 -0.50016706 0.01362912 647.00 6.14242620e+00 -1.34752359e+00 6.28849899e+00 -0.21595856 0.07109575 647.25 8.05859299e+00 -4.60706847e+00 9.28256435e+00 -0.51934798 0.24255188 647.50 1.00376552e+01 -6.99344221e+00 1.22336730e+01 -0.60852170 0.43528056 647.75 6.55044359e+00 -7.00218202e+00 9.58847560e+00 -0.81871800 0.35956460 648.00 7.56389434e+00 -6.63065237e+00 1.00587300e+01 -0.71974614 0.37643805 648.25 8.31319910e+00 -5.64611593e+00 1.00492738e+01 -0.59661221 0.34117889 648.50 7.24780862e+00 -8.55843462e+00 1.12150583e+01 -0.86812716 0.39074816 648.75 5.78742008e+00 -9.40625547e+00 1.10440877e+01 -1.01922192 0.48732288 649.00 3.25979585e+00 -9.74651332e+00 1.02771976e+01 -1.24803424 0.58885166 649.25 3.68493102e-01 -8.63801762e+00 8.64587391e+00 -1.52816272 0.64081984 649.50 -1.66538694e+00 -7.42263558e+00 7.60716982e+00 -1.79150722 0.59287623 649.75 -2.86302385e+00 -4.62294462e+00 5.43769460e+00 -2.12529162 0.47839627 650.00 -3.80951729e+00 -3.16006405e+00 4.94958854e+00 -2.44911014 0.46828089 650.25 -2.85939531e+00 8.09308336e-01 2.97172030e+00 2.86577202 0.29516338 650.50 -1.39472900e+00 1.49127331e+00 2.04185334e+00 2.32275435 0.27764615 650.75 -9.05830986e-02 1.70061783e+00 1.70302857e+00 1.62401086 0.33926997 651.00 5.02371984e-01 1.96129528e+00 2.02461275e+00 1.32004446 0.36214476 651.25 1.86802376e+00 2.42058286e+00 3.05756998e+00 0.91353572 0.45648437 651.50 2.33233344e+00 2.47632649e+00 3.40176016e+00 0.81533374 0.54015746 651.75 2.61064133e+00 2.29354293e+00 3.47502336e+00 0.72082930 0.62662409 652.00 3.04249079e+00 1.99815421e+00 3.63996847e+00 0.58110539 0.63758882 652.25 3.78341426e+00 1.63423080e+00 4.12127817e+00 0.40773926 0.66405719 652.50 3.73724545e+00 1.47619378e+00 4.01822743e+00 0.37618441 0.66838589 652.75 4.33144919e+00 1.16650295e+00 4.48577543e+00 0.26306869 0.72895783 653.00 4.53141122e+00 4.23099511e-01 4.55112084e+00 0.09310044 0.77431326 653.25 4.11595250e+00 -1.81320128e+00 4.49763981e+00 -0.41495097 0.65862870 653.50 2.99059461e+00 -2.88705219e+00 4.15676876e+00 -0.76778368 0.63630822 653.75 3.94890886e-01 -3.79924721e+00 3.81971441e+00 -1.46722897 0.59589229 654.00 -1.51645638e+00 -2.88542417e+00 3.25964915e+00 -2.05468029 0.54784832 654.25 -3.38647232e+00 -1.56678527e+00 3.73135510e+00 -2.70826069 0.71953315 654.50 -3.32811770e+00 -6.65471046e-01 3.39399752e+00 -2.94424115 0.72631820 654.75 -3.11763150e+00 4.03622048e-01 3.14365026e+00 3.01284446 0.85520412 655.00 -2.96655949e+00 3.51128628e-01 2.98726740e+00 3.02377855 0.84064749 655.25 -3.04940317e+00 3.08829114e-01 3.06500165e+00 3.04066152 0.83167431 655.50 -3.25157714e+00 -3.78872619e-02 3.25179786e+00 -3.12994122 0.81637726 655.75 -3.39022545e+00 7.83870654e-02 3.39113154e+00 3.11847528 0.64826376 656.00 -3.44612743e+00 4.79888306e-01 3.47938027e+00 3.00322808 0.61383868 656.25 -3.47924286e+00 2.39687120e-01 3.48748919e+00 3.07281073 0.61192250 656.50 -2.95598036e+00 -1.60890660e-01 2.96035567e+00 -3.08721744 0.52954474 656.75 -3.23024469e+00 -7.90391454e-01 3.32553746e+00 -2.90162285 0.54015328 657.00 -3.34327348e+00 -2.02477534e+00 3.90860496e+00 -2.59704622 0.57548222 657.25 -4.15645408e+00 -3.08541539e+00 5.17647550e+00 -2.50302545 0.66334053 657.50 -5.56350333e+00 -3.69718392e+00 6.67995047e+00 -2.55506213 0.72219902 657.75 -7.16922401e+00 -2.89537679e+00 7.73181607e+00 -2.75776145 0.71251171 658.00 -8.57342372e+00 -5.61725953e-01 8.59180600e+00 -3.07616672 0.82855239 658.25 -8.66828116e+00 3.41122797e-01 8.67499066e+00 3.10225996 0.88103726 658.50 -7.66297972e+00 1.31820186e+00 7.77553306e+00 2.97123785 0.86360404 658.75 -6.10092839e+00 2.06792484e+00 6.44186621e+00 2.81479342 0.81866119 659.00 -3.78620150e+00 8.22134150e-01 3.87443239e+00 2.92777236 0.64957206 659.25 -3.34094667e+00 2.10486946e-01 3.34757067e+00 3.07867363 0.61294006 659.50 -3.52471467e+00 -1.13767267e+00 3.70377006e+00 -2.82937890 0.69469210 659.75 -3.56499273e+00 -1.65355780e+00 3.92981254e+00 -2.70729574 0.72832665 660.00 -3.18593931e+00 -2.23491604e+00 3.89166532e+00 -2.52986498 0.51817531 660.25 -2.08718775e+00 -3.09105786e+00 3.72974415e+00 -2.16470682 0.33664009 660.50 -8.93753311e-01 -4.04310019e+00 4.14070696e+00 -1.78835407 0.48233263 660.75 -8.03984616e-01 -4.99548778e+00 5.05977168e+00 -1.73037010 0.58476727 661.00 -1.32549989e+00 -8.07723334e+00 8.18527021e+00 -1.73344979 0.72985168 661.25 -2.13736593e+00 -9.97713451e+00 1.02035066e+01 -1.78183298 0.77899473 661.50 -4.50457123e+00 -1.12561443e+01 1.21240235e+01 -1.95146456 0.85612995 661.75 -5.78120053e+00 -1.08637657e+01 1.23062457e+01 -2.05983534 0.84820926 662.00 -8.54987675e+00 -9.54072825e+00 1.28111626e+01 -2.30147756 0.85345578 662.25 -9.92744637e+00 -9.59475000e+00 1.38062819e+01 -2.37323479 0.87200274 662.50 -9.34928062e+00 -8.87117207e+00 1.28882405e+01 -2.38242868 0.83740097 662.75 -9.26186209e+00 -7.26244338e+00 1.17696718e+01 -2.47660778 0.82835811 663.00 -8.94226356e+00 -6.67257697e+00 1.11573904e+01 -2.50053805 0.88176959 663.25 -8.75697856e+00 -7.13906564e+00 1.12982712e+01 -2.45762605 0.88477499 663.50 -8.93706777e+00 -8.21400116e+00 1.21384099e+01 -2.39832823 0.89282998 663.75 -9.01636667e+00 -8.63909347e+00 1.24871455e+01 -2.37755988 0.89583305 664.00 -8.88548086e+00 -9.91426054e+00 1.33133141e+01 -2.30152594 0.91111025 664.25 -8.85224540e+00 -1.11076655e+01 1.42036080e+01 -2.24367427 0.85423098 664.50 -9.01921741e+00 -1.18879561e+01 1.49221239e+01 -2.21983289 0.74543674 664.75 -8.37446757e+00 -1.10740896e+01 1.38840617e+01 -2.21826749 0.62735994 665.00 -4.70314030e+00 -8.90834117e+00 1.00736325e+01 -2.05655149 0.20808013 665.25 -2.20189123e+00 -4.48320373e-01 2.24706834e+00 -2.94073128 0.01395764 665.50 -6.10315679e-01 4.50126792e+00 4.54245508e+00 1.70556200 0.16198413 665.75 -1.53318239e+00 2.42707047e+00 2.87076981e+00 2.13419970 0.18462134 666.00 -2.60780573e+00 1.49990414e+00 3.00838215e+00 2.61963854 0.41234850 666.25 -3.48733339e+00 1.06572927e+00 3.64654261e+00 2.84500615 0.56998306 666.50 -4.07657592e+00 8.81739990e-01 4.17084364e+00 2.92857974 0.68416192 666.75 -4.33638786e+00 3.99315167e-01 4.35473447e+00 3.04976687 0.70358934 667.00 -4.99676240e+00 6.74399227e-02 4.99721749e+00 3.12809675 0.74848226 667.25 -5.48299872e+00 7.38138843e-01 5.53246093e+00 3.00777400 0.83079673 667.50 -5.39320874e+00 1.00270653e+00 5.48562857e+00 2.95777127 0.80987268 667.75 -4.42734582e+00 9.50688216e-01 4.52826667e+00 2.93007366 0.70035218 668.00 -3.24598247e+00 9.09235750e-01 3.37092151e+00 2.86848092 0.57095415 668.25 -2.68340817e+00 5.68114940e-01 2.74288790e+00 2.93295947 0.43901867 668.50 -1.97062089e+00 4.91689816e-01 2.03103559e+00 2.89707513 0.26208811 668.75 -1.88789444e+00 -7.75361746e-01 2.04091432e+00 -2.75189472 0.27930534 669.00 -1.64630514e+00 -1.67384221e+00 2.34777945e+00 -2.34790075 0.32841195 669.25 -2.79673849e+00 -1.07190935e+00 2.99511867e+00 -2.77559030 0.34284659 669.50 -3.02202144e+00 -1.11605325e+00 3.22151958e+00 -2.78782255 0.30677484 669.75 -4.20546973e+00 9.68145426e-01 4.31546998e+00 2.91532387 0.51032685 670.00 -4.17143700e+00 1.97432772e+00 4.61506842e+00 2.69953490 0.56552734 670.25 -3.03061765e+00 2.91449126e+00 4.20462872e+00 2.37572511 0.56970856 670.50 -2.44398913e+00 3.26262975e+00 4.07649798e+00 2.21371199 0.65423820 670.75 -2.50344853e+00 2.69088393e+00 3.67533820e+00 2.32012554 0.75397758 671.00 -2.54841140e+00 2.65679712e+00 3.68143608e+00 2.33537495 0.74747400 671.25 -2.05795291e+00 2.42826685e+00 3.18302530e+00 2.27383644 0.64372907 671.50 -1.77917566e+00 2.62420967e+00 3.17047984e+00 2.16659405 0.72406287 671.75 -8.65990859e-01 2.37529305e+00 2.52823204e+00 1.92040293 0.68274831 672.00 -3.16894833e-01 2.47685150e+00 2.49704138e+00 1.69804760 0.68629694 672.25 4.86334195e-01 3.14057360e+00 3.17800621e+00 1.41716142 0.72349937 672.50 1.11483933e+00 3.23333350e+00 3.42013337e+00 1.23876540 0.76978558 672.75 1.90614785e+00 2.17814676e+00 2.89442964e+00 0.85189627 0.66178996 673.00 2.20026501e+00 2.09857182e+00 3.04058708e+00 0.76174660 0.61515475 673.25 2.52134042e+00 5.34393956e-01 2.57735027e+00 0.20885752 0.34900969 673.50 2.49626514e+00 -3.52850879e-01 2.52107981e+00 -0.14042124 0.31618911 673.75 2.80233151e+00 -1.87345796e+00 3.37089107e+00 -0.58929526 0.47265180 674.00 2.30315809e+00 -2.76999840e+00 3.60241979e+00 -0.87716140 0.49866526 674.25 1.94306818e+00 -2.55701275e+00 3.21151493e+00 -0.92099071 0.39816605 674.50 1.86200280e+00 -2.94060206e+00 3.48054520e+00 -1.00631881 0.37705677 674.75 1.68859353e+00 -4.51614468e+00 4.82150504e+00 -1.21298902 0.46489899 675.00 8.01845783e-01 -5.85077431e+00 5.90546498e+00 -1.43459532 0.58086252 675.25 -1.19258192e-01 -6.08618357e+00 6.08735188e+00 -1.59038873 0.70380119 675.50 -1.48926310e+00 -6.40911642e+00 6.57986914e+00 -1.79911103 0.69851325 675.75 -3.06006668e+00 -7.50899318e+00 8.10857488e+00 -1.95776881 0.77370658 676.00 -4.44807038e+00 -6.62115023e+00 7.97652559e+00 -2.16234245 0.78228329 676.25 -5.89725791e+00 -5.47548315e+00 8.04727076e+00 -2.39326397 0.75405032 676.50 -7.13746709e+00 -4.57034152e+00 8.47534413e+00 -2.57204467 0.79945642 676.75 -7.63114416e+00 -4.04476750e+00 8.63681106e+00 -2.65420736 0.80982959 677.00 -8.71411844e+00 -2.52814456e+00 9.07344340e+00 -2.85922407 0.86645934 677.25 -8.13627597e+00 -1.48771509e+00 8.27117180e+00 -2.96074089 0.87888330 677.50 -8.18737102e+00 -1.16024651e+00 8.26917265e+00 -3.00081828 0.90833877 677.75 -8.52999164e+00 -8.58972678e-01 8.57313195e+00 -3.04123069 0.91367975 678.00 -8.87744663e+00 3.09333451e-01 8.88283433e+00 3.10676188 0.89487990 678.25 -8.84961242e+00 1.18189369e+00 8.92818641e+00 3.00882514 0.91614611 678.50 -8.63380109e+00 1.98830699e+00 8.85979040e+00 2.91524567 0.90263454 678.75 -7.82084617e+00 2.91665537e+00 8.34700625e+00 2.78463496 0.89395138 679.00 -6.99292352e+00 3.97418749e+00 8.04332926e+00 2.62479639 0.92869674 679.25 -6.76163889e+00 4.57373336e+00 8.16325899e+00 2.54686551 0.94543213 679.50 -5.93793292e+00 5.24007159e+00 7.91943165e+00 2.41854522 0.94269257 679.75 -5.53039849e+00 5.77279607e+00 7.99440317e+00 2.33475273 0.93281144 680.00 -4.27970449e+00 6.32762569e+00 7.63902594e+00 2.16547446 0.93135086 680.25 -3.43886267e+00 6.14597115e+00 7.04263714e+00 2.08092770 0.91867426 680.50 -1.92969627e+00 5.54558083e+00 5.87172841e+00 1.90566162 0.86695906 680.75 -1.18457903e+00 5.02177660e+00 5.15959956e+00 1.80245006 0.86412365 681.00 -1.17720730e+00 4.39065325e+00 4.54572909e+00 1.83275196 0.86266681 681.25 -9.87118754e-01 4.13763742e+00 4.25375679e+00 1.80498935 0.86723755 681.50 -4.78776609e-01 3.67035252e+00 3.70144764e+00 1.70050823 0.76597918 681.75 -1.78015039e-01 3.37156270e+00 3.37625894e+00 1.62354632 0.74261645 682.00 -7.25700485e-01 1.88910458e+00 2.02369892e+00 1.93756513 0.47388004 682.25 -8.49421186e-01 1.06417528e+00 1.36161131e+00 2.24443672 0.24893745 682.50 -7.31465787e-01 2.09400085e-02 7.31765455e-01 3.11297301 0.07217918 682.75 -8.57603329e-01 -3.73777704e-01 9.35517634e-01 -2.73057650 0.10199445 683.00 -1.44680493e+00 -1.33309090e+00 1.96732708e+00 -2.39707756 0.21904147 683.25 -2.46046431e+00 -2.20712374e+00 3.30534111e+00 -2.41041783 0.39158444 683.50 -5.46078715e+00 -4.43457383e+00 7.03460314e+00 -2.45953159 0.69367118 683.75 -7.01408719e+00 -4.26542570e+00 8.20921894e+00 -2.59522197 0.73513917 684.00 -9.43441413e+00 -2.04524411e+00 9.65355859e+00 -2.92811052 0.69154782 684.25 -1.12503752e+01 2.41650168e-01 1.12529701e+01 3.12011666 0.61080419 684.50 -1.27626204e+01 4.72684938e+00 1.36098342e+01 2.78689025 0.66738525 684.75 -1.13255122e+01 7.01073685e+00 1.33198220e+01 2.58730396 0.72692901 685.00 -7.19731623e+00 1.13468778e+01 1.34370010e+01 2.13605482 0.72021210 685.25 -3.36352785e+00 1.17212634e+01 1.21943157e+01 1.85024684 0.65674191 685.50 5.67069354e-01 1.17866306e+01 1.18002639e+01 1.52272216 0.71049771 685.75 2.39774992e+00 1.01294733e+01 1.04093917e+01 1.33836426 0.66554830 686.00 4.57565660e+00 8.83924494e+00 9.95333534e+00 1.09312671 0.74139596 686.25 6.57063464e+00 6.12602797e+00 8.98339904e+00 0.75039486 0.68672978 686.50 7.70974864e+00 2.69913986e+00 8.16857270e+00 0.33675892 0.80610940 686.75 7.25478561e+00 -8.29787602e-01 7.30208612e+00 -0.11388307 0.75732274 687.00 6.27271106e+00 -4.17921871e+00 7.53742483e+00 -0.58771684 0.81056712 687.25 5.06118007e+00 -6.85521159e+00 8.52111904e+00 -0.93482750 0.79095170 687.50 2.07979884e+00 -9.56946166e+00 9.79286269e+00 -1.35678742 0.82689562 687.75 -7.58151707e-01 -1.12713035e+01 1.12967729e+01 -1.63795905 0.84277242 688.00 -2.44931978e+00 -1.21890393e+01 1.24326926e+01 -1.76909985 0.87131362 688.25 -5.99348403e+00 -1.26207728e+01 1.39716054e+01 -2.01415525 0.87064924 688.50 -8.97603928e+00 -1.34498253e+01 1.61699438e+01 -2.15928721 0.90061599 688.75 -1.17183261e+01 -1.45942283e+01 1.87165880e+01 -2.24732890 0.87199216 689.00 -1.46730776e+01 -1.57132334e+01 2.14989514e+01 -2.32197679 0.91221462 689.25 -1.92184654e+01 -1.43424201e+01 2.39802925e+01 -2.50047447 0.89918296 689.50 -2.20381065e+01 -1.42833559e+01 2.62619953e+01 -2.56653960 0.88935978 689.75 -1.63711107e+01 -1.60113256e+01 2.28992536e+01 -2.36730454 0.54262879 690.00 -9.08531568e+00 -2.18822779e+01 2.36933967e+01 -1.96432906 0.25560016 690.25 9.84076016e+00 8.49017509e+00 1.29970625e+01 0.71185314 0.16429039 690.50 6.19368974e+00 1.39917249e+01 1.53013123e+01 1.15405635 0.46581077 690.75 -1.69679828e+00 8.84889461e+00 9.01010878e+00 1.76024923 0.43156563 691.00 -4.59952628e+00 7.89300785e+00 9.13538258e+00 2.09842370 0.59537173 691.25 -7.31845544e+00 6.79954093e+00 9.98967201e+00 2.39293349 0.71419052 691.50 -7.60467219e+00 6.61569887e+00 1.00796087e+01 2.42562893 0.72151514 691.75 -9.13753241e+00 5.92059346e+00 1.08879716e+01 2.56666535 0.76850812 692.00 -9.76948233e+00 4.59555466e+00 1.07963840e+01 2.70190501 0.75926307 692.25 -1.03048034e+01 3.36434557e+00 1.08401012e+01 2.82601980 0.61606973 692.50 -1.08245288e+01 3.75244016e+00 1.14564929e+01 2.80789568 0.59324363 692.75 -1.22959220e+01 4.43986281e+00 1.30729522e+01 2.79507762 0.73356191 693.00 -1.20642588e+01 2.92268370e+00 1.24132356e+01 2.90391214 0.68137870 693.25 -1.44091853e+01 1.00950974e+00 1.44445052e+01 3.07164679 0.72591025 693.50 -1.43595510e+01 1.68333559e+00 1.44578810e+01 3.02489767 0.73510462 693.75 -1.48207614e+01 4.27097925e+00 1.54238851e+01 2.86101908 0.64423953 694.00 -1.49952176e+01 4.54037011e+00 1.56675305e+01 2.84758014 0.64874787 694.25 -1.54418347e+01 4.32542859e+00 1.60361963e+01 2.86848097 0.58485962 694.50 -1.62511908e+01 7.22710026e+00 1.77857297e+01 2.72314489 0.63455207 694.75 -1.83881828e+01 7.08308960e+00 1.97052131e+01 2.77391146 0.68075699 695.00 -1.75079183e+01 7.61187530e+00 1.90910410e+01 2.73147795 0.65547255 695.25 -1.55902872e+01 1.01847231e+01 1.86221814e+01 2.56291957 0.68297705 695.50 -1.55777642e+01 8.31144451e+00 1.76563543e+01 2.65147023 0.65144294 695.75 -1.25186252e+01 8.54505148e+00 1.51569747e+01 2.54264908 0.60214590 696.00 -1.06632047e+01 8.40637636e+00 1.35783319e+01 2.47399360 0.56992078 696.25 -1.12227463e+01 5.68214533e+00 1.25792213e+01 2.67291287 0.42292225 696.50 -9.70000122e+00 2.28703920e+00 9.96597070e+00 2.91004429 0.35805067 696.75 -8.60491805e+00 -3.36950032e-01 8.61151264e+00 -3.10245481 0.33610624 697.00 -1.02353776e+01 -5.73433436e+00 1.17322438e+01 -2.63091671 0.28486451 697.25 -1.80052440e+01 -1.18307853e+01 2.15442868e+01 -2.56026027 0.43052743 697.50 -1.82321220e+01 -1.17756625e+01 2.17042968e+01 -2.56812308 0.41970284 697.75 -1.83027390e+01 -1.15172578e+01 2.16249274e+01 -2.57993285 0.34838270 698.00 -2.34862624e+01 -2.55484073e+00 2.36248118e+01 -3.03323849 0.34384726 698.25 -2.69836823e+01 -2.35806693e+00 2.70865204e+01 -3.05442547 0.31937378 698.50 -1.45185445e+01 -7.40371948e+00 1.62973371e+01 -2.67001744 0.11872799 698.75 -3.35430517e+00 -5.66237863e+00 6.58132927e+00 -2.10559736 0.02071840 699.00 2.72897419e+00 -2.25613189e+00 3.54082353e+00 -0.69083009 0.00735432 699.25 9.98691878e+00 -4.30252388e+00 1.08742935e+01 -0.40678648 0.08130179 699.50 7.48639114e+00 -3.65059860e+00 8.32904090e+00 -0.45370377 0.07256558 699.75 9.42896748e+00 -2.74235563e+00 9.81967118e+00 -0.28303548 0.08910844 700.00 9.56268277e+00 -3.30859215e+00 1.01188776e+01 -0.33309794 0.09839753 700.25 9.71858711e+00 2.50701901e+00 1.00367365e+01 0.25245747 0.08117234 700.50 7.92418886e+00 1.69073404e+01 1.86721967e+01 1.13251442 0.19945713 700.75 6.52591710e+00 1.86328235e+01 1.97425861e+01 1.23390977 0.21741189 701.00 -1.57121078e+00 1.62020132e+01 1.62780200e+01 1.66747030 0.16927758 701.25 -1.18102292e+01 1.44178577e+01 1.86374927e+01 2.25709892 0.19150588 701.50 -2.01588335e+01 1.63970325e+01 2.59854045e+01 2.45873908 0.22947018 701.75 -3.07261910e+01 2.15326980e+01 3.75200733e+01 2.53033471 0.33771848 702.00 -4.16446629e+01 6.13090103e+00 4.20935374e+01 2.99542325 0.37579825 702.25 -3.86387778e+01 5.31465838e+00 3.90025736e+01 3.00490310 0.25523010 702.50 -1.55918322e+01 -3.11858000e+00 1.59006532e+01 -2.94418392 0.04164484 702.75 -1.29065836e+01 -1.21517066e+00 1.29636622e+01 -3.04771816 0.03581593 703.00 -2.07355366e+01 -2.34600829e+01 3.13103492e+01 -2.29462498 0.24792028 703.25 -1.37714576e+01 -2.63144792e+01 2.97002502e+01 -2.05294225 0.24344424 703.50 -5.31269729e+00 -2.01009304e+01 2.07911557e+01 -1.82918887 0.10889309 703.75 -6.87040584e+00 -1.02743399e+01 1.23597952e+01 -2.16020226 0.03401549 704.00 -2.01129642e+01 -1.03751739e+01 2.26312961e+01 -2.66534947 0.13635770 704.25 -2.17638086e+01 -2.05602955e+01 2.99397581e+01 -2.38462247 0.29476290 704.50 -2.01289810e+01 -3.04213093e+01 3.64778280e+01 -2.15533431 0.63212720 704.75 -1.33640927e+01 -2.46449661e+01 2.80352159e+01 -2.06768126 0.59481240 705.00 -2.05954562e+00 -2.42842520e+01 2.43714305e+01 -1.65540379 0.61818928 705.25 2.45357739e-01 -2.39522448e+01 2.39535015e+01 -1.56055306 0.65869723 705.50 5.81610276e+00 -2.09462041e+01 2.17386872e+01 -1.29995085 0.63541373 705.75 5.43784334e+00 -1.83421718e+01 1.91312677e+01 -1.28258423 0.62466569 706.00 7.14270298e+00 -1.54030191e+01 1.69785512e+01 -1.13659080 0.69494553 706.25 8.85412009e+00 -1.45170578e+01 1.70041292e+01 -1.02312084 0.73233912 706.50 1.11477801e+01 -1.24467298e+01 1.67091019e+01 -0.84039569 0.77895029 706.75 1.16593160e+01 -1.03892696e+01 1.56165480e+01 -0.72785958 0.76102988 707.00 1.27042179e+01 -9.43680694e+00 1.58256272e+01 -0.63888294 0.84261407 707.25 1.21332865e+01 -8.70735616e+00 1.49343461e+01 -0.62246837 0.82378999 707.50 1.31079400e+01 -7.52212780e+00 1.51129249e+01 -0.52097742 0.88298261 707.75 1.18872037e+01 -7.04307948e+00 1.38170395e+01 -0.53488102 0.85296186 708.00 1.20513229e+01 -6.26568565e+00 1.35828274e+01 -0.47945383 0.83896939 708.25 1.29688181e+01 -5.22544673e+00 1.39819718e+01 -0.38302443 0.83227508 708.50 1.41811500e+01 -4.45323989e+00 1.48639282e+01 -0.30427386 0.87245873 708.75 1.34326215e+01 -5.29889856e+00 1.44400016e+01 -0.37573859 0.86293509 709.00 1.25656947e+01 -6.23674911e+00 1.40283186e+01 -0.46070844 0.88436659 709.25 1.01553435e+01 -6.42949416e+00 1.20195423e+01 -0.56441312 0.88998086 709.50 9.45119231e+00 -6.18560394e+00 1.12954297e+01 -0.57951724 0.92557019 709.75 7.94547799e+00 -5.35016498e+00 9.57887706e+00 -0.59262197 0.87876442 710.00 7.13944138e+00 -4.58324316e+00 8.48396965e+00 -0.57070315 0.89749181 710.25 6.38400105e+00 -3.77480005e+00 7.41650759e+00 -0.53399094 0.91120982 710.50 6.08500638e+00 -3.19550165e+00 6.87302942e+00 -0.48355950 0.92692972 710.75 5.18696399e+00 -2.61540526e+00 5.80903952e+00 -0.46702318 0.91874029 711.00 4.89920456e+00 -2.40488744e+00 5.45762668e+00 -0.45631942 0.91928304 711.25 4.60364439e+00 -1.82786025e+00 4.95324286e+00 -0.37795755 0.92036304 711.50 4.49941422e+00 -1.65849264e+00 4.79534422e+00 -0.35314961 0.93890616 711.75 4.11412224e+00 -1.54357801e+00 4.39415918e+00 -0.35893734 0.94108357 712.00 3.82081939e+00 -1.47041569e+00 4.09399354e+00 -0.36737212 0.93759559 712.25 3.27037071e+00 -1.09624466e+00 3.44921396e+00 -0.32343412 0.93519564 712.50 3.00148515e+00 -1.15146991e+00 3.21477777e+00 -0.36631810 0.94078091 712.75 2.69782644e+00 -1.00567124e+00 2.87917387e+00 -0.35681497 0.91133519 713.00 2.42795279e+00 -8.24605285e-01 2.56416236e+00 -0.32740669 0.88655747 713.25 1.80943895e+00 -8.63345916e-01 2.00485298e+00 -0.44518853 0.86167702 713.50 1.53180734e+00 -9.04161670e-01 1.77874733e+00 -0.53322553 0.84686658 713.75 1.06449471e+00 -6.60803772e-01 1.25292084e+00 -0.55554996 0.80562361 714.00 9.12823255e-01 -6.22371136e-01 1.10480411e+00 -0.59841264 0.76392373 714.25 5.38932524e-01 -4.23407516e-01 6.85362816e-01 -0.66592396 0.66373325 714.50 3.84404156e-01 -4.38115175e-01 5.82847718e-01 -0.85060620 0.58932209 714.75 4.93903102e-02 -3.52625476e-01 3.56067590e-01 -1.43163713 0.37630477 715.00 -1.33883859e-01 -2.63946124e-01 2.95960207e-01 -2.04021862 0.36210191 715.25 -3.71452337e-01 -1.70646150e-01 4.08774935e-01 -2.71094713 0.68382196 715.50 -4.77610319e-01 -5.70475802e-02 4.81005242e-01 -3.02271209 0.73126887 715.75 -6.27060429e-01 1.20061266e-01 6.38450851e-01 2.95241538 0.86039462 716.00 -6.53315427e-01 1.94789372e-01 6.81735980e-01 2.85182922 0.89067943 716.25 -6.75516759e-01 2.20107414e-01 7.10471791e-01 2.82660516 0.93358613 716.50 -7.03359403e-01 2.05358383e-01 7.32725402e-01 2.85752093 0.92452243 716.75 -7.74210266e-01 1.72712754e-01 7.93240967e-01 2.92210407 0.94297375 717.00 -8.43710104e-01 1.71606700e-01 8.60985249e-01 2.94093449 0.95193412 717.25 -9.23455957e-01 2.17384909e-01 9.48697583e-01 2.91039820 0.97147609 717.50 -9.40165867e-01 2.29409627e-01 9.67750295e-01 2.90225978 0.96512917 717.75 -9.26400262e-01 2.41576905e-01 9.57380199e-01 2.88650398 0.95939044 718.00 -8.78615340e-01 2.69583950e-01 9.19043210e-01 2.84388330 0.92106794 718.25 -8.30439788e-01 2.59182523e-01 8.69945872e-01 2.83906975 0.92928910 718.50 -7.94098140e-01 2.48299006e-01 8.32012171e-01 2.83854335 0.92029696 718.75 -7.31902575e-01 2.22234297e-01 7.64898334e-01 2.84680052 0.89568872 719.00 -6.46535161e-01 7.99694001e-02 6.51462063e-01 3.01852853 0.82188843 719.25 -5.69833060e-01 -2.89216086e-02 5.70566539e-01 -3.09088164 0.77372475 719.50 -5.90751063e-01 -1.86320470e-01 6.19436951e-01 -2.83607170 0.79754153 719.75 -5.32340745e-01 -3.89069472e-01 6.59364636e-01 -2.51045053 0.87254466 720.00 -4.71794649e-01 -4.95232164e-01 6.83992023e-01 -2.33196256 0.87380240 720.25 -4.75392265e-01 -5.99150988e-01 7.64839664e-01 -2.24152640 0.85570781 720.50 -6.51036478e-01 -8.64151761e-01 1.08194582e+00 -2.21645848 0.90328453 720.75 -7.89510168e-01 -1.04857734e+00 1.31257028e+00 -2.21617294 0.91695998 721.00 -1.20005726e+00 -1.22834429e+00 1.71725570e+00 -2.34454660 0.94650105 721.25 -1.39819463e+00 -1.16242171e+00 1.81828833e+00 -2.44801222 0.96185593 721.50 -1.54874630e+00 -8.80779355e-01 1.78168106e+00 -2.62450230 0.95991490 721.75 -1.60199026e+00 -6.25517852e-01 1.71978062e+00 -2.76933481 0.95408578 722.00 -1.42716825e+00 -3.67057679e-01 1.47361480e+00 -2.88985565 0.94336702 722.25 -1.36099827e+00 -3.10941119e-01 1.39606614e+00 -2.91698218 0.95308210 722.50 -1.06185138e+00 -3.07408432e-01 1.10545389e+00 -2.85979437 0.92897874 722.75 -9.90555877e-01 -3.46975232e-01 1.04956789e+00 -2.80466543 0.92700004 723.00 -8.93698196e-01 -4.69336968e-01 1.00944225e+00 -2.65801811 0.86879126 723.25 -7.91348585e-01 -5.06881307e-01 9.39766589e-01 -2.57190464 0.80453384 723.50 -8.13408733e-01 -6.59280279e-01 1.04703594e+00 -2.46047271 0.75351579 723.75 -7.92969210e-01 -7.69999549e-01 1.10530515e+00 -2.37088961 0.80393444 724.00 -7.27668693e-01 -8.11383447e-01 1.08988294e+00 -2.30185433 0.84052115 724.25 -6.93018592e-01 -8.94112334e-01 1.13124340e+00 -2.23016336 0.87342960 724.50 -7.39685409e-01 -1.20437565e+00 1.41338431e+00 -2.12156624 0.86818878 724.75 -9.13224687e-01 -1.30568143e+00 1.59335599e+00 -2.18113549 0.86502915 725.00 -1.30827541e+00 -1.02795674e+00 1.66381478e+00 -2.47561110 0.78593073 725.25 -1.41424164e+00 -9.28398698e-01 1.69174571e+00 -2.56068675 0.74255488 725.50 -1.41925573e+00 -7.17208845e-01 1.59018092e+00 -2.67368097 0.69246695 725.75 -1.26428791e+00 -4.60697239e-01 1.34560985e+00 -2.79215384 0.58329728 726.00 -7.32099691e-01 -2.80496531e-01 7.83995065e-01 -2.77570489 0.33398337 726.25 -4.49565004e-01 -5.20685001e-01 6.87911013e-01 -2.28302466 0.32328840 726.50 -5.11008351e-01 -7.67251459e-01 9.21848326e-01 -2.15835430 0.60268546 726.75 -6.17708394e-01 -7.35000310e-01 9.60098493e-01 -2.26970190 0.61099789 727.00 -6.24783082e-01 -6.79423193e-01 9.23022088e-01 -2.31432368 0.64259542 727.25 -6.78352477e-01 -7.36213850e-01 1.00108587e+00 -2.31531331 0.68318046 727.50 -7.37415283e-01 -7.03916941e-01 1.01945101e+00 -2.37943154 0.74605268 727.75 -7.20041059e-01 -5.85279162e-01 9.27906689e-01 -2.45907051 0.64415530 728.00 -5.98600505e-01 -4.15194894e-01 7.28498019e-01 -2.53516862 0.60607208 728.25 -5.59501946e-01 -3.93269994e-01 6.83888672e-01 -2.52892772 0.59467783 728.50 -5.75186621e-01 -3.52516599e-01 6.74616633e-01 -2.59176113 0.62712886 728.75 -4.46470142e-01 -3.55143978e-01 5.70493499e-01 -2.46963322 0.52710239 729.00 -4.36664438e-01 -3.83068427e-01 5.80876278e-01 -2.42148385 0.64049577 729.25 -4.61075402e-01 -3.58928242e-01 5.84311569e-01 -2.48012525 0.63050396 729.50 -3.86699703e-01 -2.52726068e-01 4.61960091e-01 -2.56272863 0.59354892 729.75 -2.04838372e-01 -3.33302071e-01 3.91214812e-01 -2.12186224 0.46650193 730.00 -1.36050989e-01 -4.00874985e-01 4.23332759e-01 -1.89798353 0.61872662 730.25 -1.30571335e-01 -5.10590771e-01 5.27021640e-01 -1.82115686 0.60814586 730.50 -7.40811990e-02 -5.97390389e-01 6.01966196e-01 -1.69417448 0.67560227 730.75 -1.35097831e-01 -6.89645917e-01 7.02753808e-01 -1.76424118 0.77287279 731.00 -1.15175368e-01 -7.02159020e-01 7.11542447e-01 -1.73337882 0.82681290 731.25 -1.84957909e-01 -5.73547549e-01 6.02632740e-01 -1.88274775 0.73230025 731.50 -2.13138267e-01 -4.90729875e-01 5.35017506e-01 -1.98054220 0.65388558 731.75 -1.64067378e-01 -4.11980097e-01 4.43447522e-01 -1.94978543 0.60893309 732.00 -1.66770322e-01 -3.61777091e-01 3.98365415e-01 -2.00273978 0.56537053 732.25 -7.85202420e-02 -4.26674361e-01 4.33839185e-01 -1.75278858 0.47698985 732.50 -5.60870709e-03 -4.42589759e-01 4.42625296e-01 -1.58346812 0.45332748 732.75 9.96874972e-02 -3.46723884e-01 3.60770077e-01 -1.29083483 0.36373363 733.00 1.63727844e-01 -3.48146425e-01 3.84724239e-01 -1.13120249 0.37139014 733.25 2.03882237e-01 -3.68701539e-01 4.21317922e-01 -1.06567295 0.33651252 733.50 3.12952955e-01 -3.13220591e-01 4.42771601e-01 -0.78582558 0.35203393 733.75 5.62621589e-01 -3.79092913e-01 6.78420584e-01 -0.59292297 0.62383965 734.00 5.68472043e-01 -5.60288640e-01 7.98175308e-01 -0.77814839 0.65547211 734.25 6.44402031e-01 -8.07639121e-01 1.03321582e+00 -0.89734719 0.70642385 734.50 7.29365594e-01 -8.85483613e-01 1.14719458e+00 -0.88177518 0.72262251 734.75 6.27046490e-01 -1.29877612e+00 1.44222284e+00 -1.12100479 0.79005740 735.00 3.83877296e-01 -1.38039238e+00 1.43277525e+00 -1.29955697 0.79284244 735.25 -8.49321723e-02 -1.48961274e+00 1.49203204e+00 -1.62775094 0.80795539 735.50 -2.48583875e-01 -1.52878896e+00 1.54886721e+00 -1.73198744 0.79455532 735.75 -5.89600931e-01 -1.26981369e+00 1.40002002e+00 -2.00549542 0.79101230 736.00 -6.39210948e-01 -9.88278189e-01 1.17698106e+00 -2.14491343 0.75255817 736.25 -7.97389851e-01 -5.66778449e-01 9.78298720e-01 -2.52366030 0.64445517 736.50 -8.43147838e-01 -1.83076281e-01 8.62794994e-01 -2.92777743 0.51988954 736.75 -5.68854309e-01 2.89128694e-01 6.38114901e-01 2.67135499 0.39458696 737.00 -4.17706372e-01 4.54087455e-01 6.16987868e-01 2.31448740 0.29418918 737.25 1.88578142e-01 8.23750830e-01 8.45060439e-01 1.34574803 0.41268391 737.50 5.82852933e-01 7.33120043e-01 9.36580236e-01 0.89909281 0.46015250 737.75 1.27783257e+00 6.14715576e-01 1.41800258e+00 0.44838204 0.59122403 738.00 1.55474150e+00 3.76518032e-01 1.59968339e+00 0.23759960 0.60223867 738.25 2.06464844e+00 -3.67475958e-01 2.09709603e+00 -0.17614026 0.70278755 738.50 2.09375367e+00 -6.79183991e-01 2.20115772e+00 -0.31367629 0.73857670 738.75 1.70005338e+00 -8.77584708e-01 1.91320057e+00 -0.47653142 0.73945130 739.00 1.46349924e+00 -1.05425613e+00 1.80368678e+00 -0.62426452 0.71827029 739.25 1.23507193e+00 -1.23836960e+00 1.74898883e+00 -0.78673140 0.69629731 739.50 1.31437905e+00 -1.28388921e+00 1.83737960e+00 -0.77366402 0.75627039 739.75 1.34661252e+00 -1.28007310e+00 1.85794306e+00 -0.76007150 0.76141383 740.00 1.29025933e+00 -1.16852923e+00 1.74075549e+00 -0.73593039 0.71219531 740.25 1.36224551e+00 -1.33265960e+00 1.90570051e+00 -0.77442014 0.70985557 740.50 1.21820533e+00 -1.52474047e+00 1.95162950e+00 -0.89669038 0.72073220 740.75 1.10345927e+00 -1.66791880e+00 1.99989387e+00 -0.98632456 0.75645777 741.00 9.59973562e-01 -2.13385141e+00 2.33984425e+00 -1.14804357 0.76443219 741.25 7.85728086e-01 -2.27725233e+00 2.40899290e+00 -1.23855294 0.81312343 741.50 5.14527573e-01 -1.95739310e+00 2.02388892e+00 -1.31374778 0.73373163 741.75 3.69159120e-01 -1.68797916e+00 1.72787502e+00 -1.35548743 0.63138161 742.00 3.21568332e-01 -1.75720509e+00 1.78638628e+00 -1.38979918 0.61839968 742.25 4.81685491e-01 -2.00026043e+00 2.05744081e+00 -1.33448429 0.68028994 742.50 2.87295336e-01 -2.28997351e+00 2.30792488e+00 -1.44599047 0.72183406 742.75 2.46753086e-01 -2.31699180e+00 2.33009401e+00 -1.46469905 0.66996795 743.00 2.20422378e-01 -1.78143442e+00 1.79501939e+00 -1.44768895 0.52973231 743.25 1.01514222e-01 -1.69367988e+00 1.69671939e+00 -1.51093087 0.40871067 743.50 -9.30816464e-02 -1.36751182e+00 1.37067602e+00 -1.63875793 0.30483896 743.75 -3.31602660e-01 -1.32045683e+00 1.36145751e+00 -1.81683563 0.30932456 744.00 -6.37438394e-01 -1.08909196e+00 1.26192274e+00 -2.10033200 0.25712109 744.25 -3.88243815e-01 -8.12808974e-01 9.00772828e-01 -2.01641022 0.19320662 744.50 3.83175561e-01 -9.24997023e-01 1.00122076e+00 -1.17807026 0.31105548 744.75 3.03978745e-01 -1.20428254e+00 1.24205456e+00 -1.32354620 0.45224992 745.00 1.93066438e-01 -1.25706870e+00 1.27180831e+00 -1.41840248 0.47431936 745.25 4.93792791e-03 -1.29718941e+00 1.29719881e+00 -1.56698971 0.44987327 745.50 -1.41176344e-01 -1.65008005e+00 1.65610837e+00 -1.65614575 0.61936286 745.75 -1.86904549e-01 -1.42909142e+00 1.44126180e+00 -1.70084378 0.59004962 746.00 -3.86304398e-01 -1.19684543e+00 1.25764465e+00 -1.88300889 0.58291413 746.25 -5.86329112e-01 -1.27430603e+00 1.40272510e+00 -2.00203114 0.58219640 746.50 -5.86061082e-01 -1.26014146e+00 1.38975684e+00 -2.00611618 0.60216276 746.75 -5.21439000e-01 -1.15751760e+00 1.26954544e+00 -1.99404969 0.58415058 747.00 -8.13886019e-01 -1.11491037e+00 1.38037516e+00 -2.20137493 0.65973612 747.25 -8.03655624e-01 -1.09396889e+00 1.35743519e+00 -2.20438384 0.63391569 747.50 -8.30159891e-01 -1.10931553e+00 1.38554913e+00 -2.21324269 0.59154129 747.75 -1.03967077e+00 -6.30299071e-01 1.21580929e+00 -2.59659117 0.49966151 748.00 -1.18569574e+00 -1.38053593e-01 1.19370565e+00 -3.02568199 0.62559368 748.25 -1.11422570e+00 7.24211654e-02 1.11657680e+00 3.07668710 0.49392884 748.50 -5.35791741e-01 3.25363242e-01 6.26844502e-01 2.59585426 0.25769678 748.75 -5.14890757e-02 5.61035720e-01 5.63393471e-01 1.66231500 0.16023164 749.00 5.76071507e-01 5.26044893e-01 7.80116409e-01 0.74003789 0.29629946 749.25 8.79268015e-01 4.69213465e-01 9.96631084e-01 0.49019683 0.39938035 749.50 1.31431337e+00 1.58420890e-01 1.32382657e+00 0.11995639 0.62085287 749.75 1.36141648e+00 -2.78743271e-02 1.36170180e+00 -0.02047164 0.59135293 750.00 1.47704132e+00 -4.64197976e-01 1.54826704e+00 -0.30450164 0.68037424 750.25 1.77818865e+00 -7.03661288e-01 1.91235302e+00 -0.37680957 0.69405564 750.50 1.87193394e+00 -1.22322789e+00 2.23616260e+00 -0.57880145 0.74055678 750.75 1.76743890e+00 -1.82371928e+00 2.53964412e+00 -0.80106881 0.76716334 751.00 1.65610523e+00 -2.14569445e+00 2.71047767e+00 -0.91347156 0.76040967 751.25 1.00435890e+00 -2.49683282e+00 2.69126568e+00 -1.18834908 0.65003672 751.50 2.41394496e-01 -2.35133009e+00 2.36368875e+00 -1.46849179 0.47988789 751.75 -5.30884428e-01 -1.61951173e+00 1.70430529e+00 -1.88756337 0.25303149 752.00 -8.09610543e-01 -1.41085206e+00 1.62664463e+00 -2.09176224 0.26691076 752.25 -2.07061099e-01 -7.09399849e-02 2.18876176e-01 -2.81152173 0.00484313 752.50 -2.75390826e-01 6.38166360e-01 6.95051372e-01 1.97818874 0.04408706 752.75 6.45677369e-01 1.55449271e+00 1.68325484e+00 1.17711730 0.28106855 753.00 6.91848767e-01 1.86425679e+00 1.98849393e+00 1.21543833 0.36468191 753.25 1.54120816e+00 1.69072544e+00 2.28776641e+00 0.83162769 0.32615870 753.50 1.69716124e+00 1.67435053e+00 2.38407340e+00 0.77863254 0.39889571 753.75 2.38022262e+00 1.79025641e+00 2.97833472e+00 0.64486817 0.49177078 754.00 2.77385975e+00 1.41144742e+00 3.11231132e+00 0.47069361 0.48756074 754.25 3.24442382e+00 1.09887843e+00 3.42546635e+00 0.32657056 0.40731326 754.50 3.63685488e+00 1.13279604e+00 3.80919155e+00 0.30195246 0.41706693 754.75 4.52772518e+00 1.87826868e+00 4.90185562e+00 0.39323124 0.36250799 755.00 4.30969143e+00 2.07401556e+00 4.78277960e+00 0.44853099 0.20402045 755.25 4.58316498e+00 1.41900130e+00 4.79780845e+00 0.30025134 0.10856067 755.50 5.73866461e+00 -4.45517399e-01 5.75593235e+00 -0.07747892 0.13241961 755.75 4.82817273e+00 -6.90886532e+00 8.42874082e+00 -0.96085113 0.36139829 756.00 2.83580867e+00 -8.06483330e+00 8.54887987e+00 -1.23267329 0.40148389 756.25 -1.39851178e-01 -6.99894693e+00 7.00034402e+00 -1.59077541 0.19581481 756.50 -4.51967537e+00 -3.48720587e+00 5.70859617e+00 -2.48443462 0.13653287 756.75 -5.58457579e+00 -2.82693857e+00 6.25931852e+00 -2.67299361 0.30024419 757.00 -5.34949958e+00 -3.12951900e+00 6.19766366e+00 -2.61226698 0.36552750 757.25 -5.28704343e+00 -1.22601152e+00 5.42733199e+00 -2.91373014 0.42654736 757.50 -4.55269517e+00 -4.81047424e-01 4.57803888e+00 -3.03632114 0.42913956 757.75 -4.50881761e+00 -2.49213716e-01 4.51569969e+00 -3.08637632 0.48031082 758.00 -4.31986101e+00 5.65812916e-01 4.35675835e+00 3.01135462 0.54004424 758.25 -3.33185961e+00 1.24784854e+00 3.55786656e+00 2.78324275 0.57325020 758.50 -3.24583843e+00 1.28545586e+00 3.49111213e+00 2.76451165 0.66450478 758.75 -3.03109212e+00 1.81319953e+00 3.53202662e+00 2.60249768 0.70231104 759.00 -2.36088852e+00 1.92075380e+00 3.04353245e+00 2.45863046 0.65389645 759.25 -1.87212863e+00 2.08083776e+00 2.79906259e+00 2.30344536 0.66116011 759.50 -1.60561056e+00 1.95708022e+00 2.53143206e+00 2.25785981 0.66169790 759.75 -1.45175009e+00 1.82538754e+00 2.33229887e+00 2.24267134 0.70167369 760.00 -8.43879010e-01 1.50320633e+00 1.72387965e+00 2.08233915 0.65028510 760.25 -7.11791598e-01 1.43599086e+00 1.60272176e+00 2.03098177 0.74672263 760.50 -5.10293620e-01 1.28897233e+00 1.38630778e+00 1.94775617 0.72087328 760.75 -4.65065836e-01 1.19227136e+00 1.27976452e+00 1.94271064 0.76631922 761.00 -4.31679029e-01 9.55044488e-01 1.04807288e+00 1.99531127 0.74931743 761.25 -4.08389261e-01 8.59684737e-01 9.51756079e-01 2.01428169 0.78701037 761.50 -4.54911777e-01 7.81163618e-01 9.03969758e-01 2.09813788 0.70629223 761.75 -5.27920621e-01 5.45007140e-01 7.58770693e-01 2.34027070 0.63637246 762.00 -4.62943121e-01 5.46732840e-01 7.16402912e-01 2.27339747 0.64397185 762.25 -4.20214349e-01 5.25149644e-01 6.72578805e-01 2.24564714 0.61375657 762.50 -2.69292248e-01 4.64828273e-01 5.37199812e-01 2.09588392 0.55402514 762.75 -2.20677449e-01 4.31462796e-01 4.84622204e-01 2.04357258 0.55074271 763.00 -1.71377223e-01 3.20423290e-01 3.63374789e-01 2.06193086 0.43157701 763.25 -2.10719237e-01 2.65666842e-01 3.39089174e-01 2.24135936 0.38363747 763.50 -1.45916659e-01 2.51044516e-01 2.90370488e-01 2.09730613 0.29964763 763.75 -1.24721876e-01 2.61970283e-01 2.90144749e-01 2.01513501 0.30905733 764.00 -2.39809288e-02 6.72701651e-02 7.14168052e-02 1.91323834 0.02953001 764.25 4.84100753e-02 -3.36444956e-02 5.89532652e-02 -0.60735531 0.02524821 764.50 9.86963171e-02 -1.47099374e-01 1.77141720e-01 -0.97983424 0.18071465 764.75 1.57084656e-01 -2.44809217e-01 2.90873068e-01 -1.00030530 0.35612024 765.00 1.44862924e-01 -4.90534900e-01 5.11478010e-01 -1.28364208 0.67386131 765.25 8.57462601e-02 -6.21228098e-01 6.27117829e-01 -1.43363597 0.72653146 765.50 -6.63649267e-02 -8.81748901e-01 8.84242856e-01 -1.64591979 0.86731683 765.75 -1.43800807e-01 -9.48428787e-01 9.59268386e-01 -1.72127028 0.88234414 766.00 -4.06730126e-01 -1.10967995e+00 1.18187097e+00 -1.92211996 0.90357220 766.25 -5.47499686e-01 -1.19753013e+00 1.31675142e+00 -1.99961396 0.90847081 766.50 -1.06135265e+00 -1.23479893e+00 1.62824993e+00 -2.28079985 0.91662555 766.75 -1.19590587e+00 -1.15554199e+00 1.66296968e+00 -2.37335835 0.90805101 767.00 -1.43081881e+00 -6.83231883e-01 1.58557506e+00 -2.69609747 0.84799419 767.25 -1.58984351e+00 -5.29097391e-01 1.67557347e+00 -2.82032361 0.82110045 767.50 -1.76659673e+00 -4.63069900e-02 1.76720354e+00 -3.11538611 0.76477911 767.75 -1.82676936e+00 4.69341926e-01 1.88609865e+00 2.89010744 0.80336621 768.00 -1.57047982e+00 9.73147066e-01 1.84754488e+00 2.58685013 0.80062170 768.25 -1.37136751e+00 1.20410046e+00 1.82496761e+00 2.42104968 0.75792674 768.50 -9.95076360e-01 1.57717785e+00 1.86485038e+00 2.13364290 0.70500105 768.75 -4.32290702e-01 1.61146622e+00 1.66844197e+00 1.83288497 0.63129587 769.00 3.26801849e-01 1.69889648e+00 1.73004298e+00 1.38075639 0.72427653 769.25 6.99782790e-01 1.49025933e+00 1.64638052e+00 1.13178675 0.68797730 769.50 1.21940278e+00 9.00487036e-01 1.51585621e+00 0.63607815 0.58375534 769.75 1.45585590e+00 5.91621690e-01 1.57147466e+00 0.38598893 0.62165648 770.00 1.77266192e+00 4.38324287e-01 1.82604996e+00 0.24240663 0.67011168 770.25 1.97243305e+00 -1.63588429e-02 1.97250088e+00 -0.00829355 0.64799987 770.50 2.11641727e+00 -6.82256385e-01 2.22366720e+00 -0.31184573 0.59135767 770.75 1.47859623e+00 -1.27551794e+00 1.95273983e+00 -0.71179503 0.44414711 771.00 1.03026937e+00 -1.64983852e+00 1.94510208e+00 -1.01258053 0.41340199 771.25 6.95884467e-01 -1.74840438e+00 1.88180049e+00 -1.19200564 0.32873855 771.50 -3.66252576e-01 -2.16517703e+00 2.19593546e+00 -1.73836603 0.49693215 771.75 -1.07963545e+00 -1.55435769e+00 1.89252227e+00 -2.17787964 0.42782383 772.00 -1.35260432e+00 -1.31947041e+00 1.88958742e+00 -2.36859393 0.55055111 772.25 -1.33691815e+00 -1.35164370e+00 1.90112883e+00 -2.35071743 0.62742447 772.50 -1.36336127e+00 -1.29738499e+00 1.88201003e+00 -2.38098556 0.65486919 772.75 -1.49253026e+00 -1.41720865e+00 2.05818535e+00 -2.38207475 0.63719417 773.00 -1.51579320e+00 -1.66055169e+00 2.24834627e+00 -2.31065208 0.69834011 773.25 -1.68265947e+00 -1.16731177e+00 2.04791593e+00 -2.53508698 0.61776332 773.50 -2.06027361e+00 -1.30968302e+00 2.44131050e+00 -2.57534731 0.65482003 773.75 -2.33968909e+00 -1.32116558e+00 2.68693571e+00 -2.62755197 0.61261016 774.00 -2.40261089e+00 -1.07062249e+00 2.63035579e+00 -2.72239717 0.61198208 774.25 -2.80431407e+00 -4.95177116e-01 2.84769693e+00 -2.96681734 0.68453475 774.50 -3.04809073e+00 1.26110255e-01 3.05069843e+00 3.10024271 0.76119309 774.75 -2.83709387e+00 4.99886156e-01 2.88079638e+00 2.96718623 0.81170107 775.00 -2.59041911e+00 7.44101052e-01 2.69517301e+00 2.86187263 0.77872794 775.25 -2.23373154e+00 1.47715285e+00 2.67797258e+00 2.55731895 0.85282180 775.50 -2.13555203e+00 1.67476155e+00 2.71392865e+00 2.47654251 0.87845330 775.75 -1.57580179e+00 1.61473972e+00 2.25622154e+00 2.34399092 0.82775659 776.00 -1.32242534e+00 1.65755814e+00 2.12044989e+00 2.24420375 0.83550875 776.25 -9.29659439e-01 1.70054414e+00 1.93807044e+00 2.07108972 0.83618637 776.50 -6.62964125e-01 1.71769981e+00 1.84119909e+00 1.93914133 0.84614987 776.75 -3.01967233e-01 1.61948405e+00 1.64739576e+00 1.75513836 0.91022348 777.00 -1.91843621e-01 1.54069831e+00 1.55259629e+00 1.69467604 0.89478721 777.25 1.29139532e-01 1.28144916e+00 1.28793981e+00 1.47035925 0.78692603 777.50 5.86748336e-02 1.13375673e+00 1.13527401e+00 1.51908988 0.75102278 777.75 2.24471637e-01 8.93812012e-01 9.21567918e-01 1.32474534 0.77193504 778.00 3.16379265e-01 8.16426466e-01 8.75584385e-01 1.20109712 0.71041853 778.25 9.96760776e-02 4.50294389e-01 4.61194489e-01 1.35295148 0.40074933 778.50 8.98196261e-02 4.99537057e-01 5.07547866e-01 1.39289157 0.48541363 778.75 6.26783344e-02 5.79866590e-01 5.83244233e-01 1.46312341 0.61807312 779.00 9.34556187e-02 6.13115241e-01 6.20196945e-01 1.41953315 0.62725536 779.25 1.77143037e-01 5.99556163e-01 6.25177773e-01 1.28351266 0.53921302 779.50 3.25697503e-01 5.89122637e-01 6.73159970e-01 1.06576628 0.57262531 779.75 5.56312697e-01 5.45959129e-01 7.79458265e-01 0.77600550 0.71972534 780.00 7.15169582e-01 4.34550167e-01 8.36840115e-01 0.54600241 0.70076043 780.25 8.34088385e-01 3.61875817e-02 8.34873029e-01 0.04335860 0.68391345 780.50 6.78207488e-01 -1.21132493e-01 6.88940112e-01 -0.17674317 0.52943052 780.75 5.58206054e-01 -3.76488458e-01 6.73303466e-01 -0.59337959 0.55657332 781.00 4.33378379e-01 -5.08841878e-01 6.68383779e-01 -0.86531871 0.60503376 781.25 1.85416385e-01 -5.61427659e-01 5.91253120e-01 -1.25181546 0.48637012 781.50 -5.56626818e-02 -4.66822782e-01 4.70129604e-01 -1.68947330 0.31598599 781.75 -4.27592218e-02 -2.78063704e-01 2.81332142e-01 -1.72337606 0.15539709 782.00 1.69753392e-02 -6.40772541e-03 1.81444506e-02 -0.36093666 0.00055738 782.25 6.03260006e-02 1.91066444e-01 2.00363700e-01 1.26496872 0.06984358 782.50 3.58111784e-01 1.53144386e-01 3.89483315e-01 0.40410808 0.17125346 782.75 7.94817054e-01 6.30969078e-02 7.97317609e-01 0.07921931 0.44849599 783.00 9.18350898e-01 -2.61725570e-01 9.54918135e-01 -0.27763469 0.33262633 783.25 7.46294118e-01 -1.02477701e+00 1.26772348e+00 -0.94136098 0.31525793 783.50 7.96196626e-01 -1.61836696e+00 1.80361878e+00 -1.11358904 0.44976652 783.75 6.71321481e-01 -1.86143930e+00 1.97879478e+00 -1.22466858 0.51292745 784.00 -6.36864329e-01 -2.31538493e+00 2.40137534e+00 -1.83921613 0.49094876 784.25 -1.52274338e+00 -2.51838286e+00 2.94295763e+00 -2.11462886 0.68809352 784.50 -2.11995916e+00 -1.95204212e+00 2.88178682e+00 -2.39740812 0.72030165 784.75 -2.26007296e+00 -1.67016029e+00 2.81022511e+00 -2.50517842 0.66975233 785.00 -2.72912317e+00 -6.12503494e-01 2.79701158e+00 -2.92081859 0.69742434 785.25 -3.17314778e+00 -8.43783256e-02 3.17426945e+00 -3.11500756 0.77088461 785.50 -2.90554605e+00 5.52029734e-01 2.95752171e+00 2.95383868 0.74389168 785.75 -2.83159558e+00 1.13613940e+00 3.05102381e+00 2.76002082 0.74272595 786.00 -2.33468664e+00 2.61108657e+00 3.50264682e+00 2.30036647 0.78709063 786.25 -1.80714924e+00 2.93183881e+00 3.44404809e+00 2.12317851 0.83653657 786.50 -1.06032537e+00 3.00329388e+00 3.18497472e+00 1.91018940 0.90109397 786.75 -6.11364839e-01 2.91334074e+00 2.97679714e+00 1.77764495 0.86681889 787.00 3.14404410e-02 2.50528397e+00 2.50548125e+00 1.55824733 0.88871431 787.25 4.17602551e-01 2.34245427e+00 2.37938730e+00 1.39437413 0.88864185 787.50 9.15249041e-01 1.74869659e+00 1.97373265e+00 1.08861286 0.89102070 787.75 9.59759598e-01 1.61899743e+00 1.88209754e+00 1.03567957 0.89213761 788.00 8.95993470e-01 1.43097969e+00 1.68834451e+00 1.01137773 0.89017442 788.25 9.02606644e-01 1.23337358e+00 1.52836813e+00 0.93903273 0.86276792 788.50 8.71831266e-01 1.09862716e+00 1.40252322e+00 0.89999195 0.88894611 788.75 9.39516916e-01 1.02279130e+00 1.38881031e+00 0.82780967 0.88201662 789.00 1.08139199e+00 8.74357058e-01 1.39065053e+00 0.67993129 0.91690703 789.25 1.12727817e+00 7.59291865e-01 1.35914687e+00 0.59276119 0.90141746 789.50 1.12815125e+00 5.13310747e-01 1.23944067e+00 0.42700556 0.88000413 789.75 9.86668586e-01 4.10438856e-01 1.06863228e+00 0.39420974 0.86611167 790.00 9.08673084e-01 4.16975137e-01 9.99777495e-01 0.43021689 0.88208420 790.25 7.71380630e-01 4.45111458e-01 8.90590976e-01 0.52336019 0.79799879 790.50 6.40575279e-01 6.06872644e-01 8.82400756e-01 0.75838747 0.74878402 790.75 7.50502147e-01 9.43138438e-01 1.20530643e+00 0.89865240 0.76395734 791.00 1.01797345e+00 1.41657630e+00 1.74440774e+00 0.94768580 0.88842349 791.25 1.39090514e+00 1.58901152e+00 2.11177052e+00 0.85178099 0.86015044 791.50 2.07439372e+00 1.62280225e+00 2.63374191e+00 0.66385590 0.89116387 791.75 2.84342822e+00 1.52951816e+00 3.22870096e+00 0.49351634 0.88536589 792.00 3.52349560e+00 1.43016750e+00 3.80268331e+00 0.38557750 0.91489795 792.25 3.90418199e+00 6.96013490e-01 3.96573723e+00 0.17642044 0.88188461 792.50 4.21410276e+00 -6.27114789e-02 4.21456935e+00 -0.01488024 0.89707780 792.75 4.62099519e+00 -7.30577373e-01 4.67839073e+00 -0.15680173 0.83166396 793.00 5.82296359e+00 -1.63560292e+00 6.04831397e+00 -0.27383233 0.86187462 793.25 6.14854269e+00 -3.28795483e+00 6.97246184e+00 -0.49106235 0.82448972 793.50 5.61832828e+00 -4.99677537e+00 7.51886805e+00 -0.72691131 0.79383764 793.75 3.33894644e+00 -7.14472849e+00 7.88642558e+00 -1.13362454 0.78356227 794.00 1.64230668e+00 -8.03612873e+00 8.20222751e+00 -1.36920681 0.81301892 794.25 -1.10495459e+00 -8.08364098e+00 8.15880972e+00 -1.70664464 0.76619991 794.50 -3.31280248e+00 -7.21951379e+00 7.94330156e+00 -2.00100021 0.73697320 794.75 -5.32063029e+00 -5.21079209e+00 7.44724519e+00 -2.36662368 0.76349515 795.00 -5.52616499e+00 -4.06210816e+00 6.85851458e+00 -2.50771659 0.76560678 795.25 -5.39281291e+00 -2.19633380e+00 5.82291278e+00 -2.75483433 0.82940641 795.50 -5.39101496e+00 -1.56991719e+00 5.61495167e+00 -2.85821951 0.83247129 795.75 -5.12876861e+00 -5.54589330e-01 5.15866618e+00 -3.03387814 0.82103571 796.00 -4.98088903e+00 2.04521989e-01 4.98508623e+00 3.10055436 0.79413162 796.25 -4.48123808e+00 1.51626363e+00 4.73080861e+00 2.81532656 0.83106031 796.50 -4.47523401e+00 2.03069768e+00 4.91441273e+00 2.71561344 0.86374385 796.75 -4.06377083e+00 2.87530849e+00 4.97811533e+00 2.52581959 0.84356254 797.00 -3.27884566e+00 3.38954268e+00 4.71591226e+00 2.33959575 0.80958777 797.25 -1.61139852e+00 4.24837003e+00 4.54370477e+00 1.93332983 0.81151005 797.50 -7.73084904e-01 4.46423189e+00 4.53067618e+00 1.74226884 0.81602537 797.75 7.67564549e-01 3.97062505e+00 4.04413385e+00 1.37984092 0.73837929 798.00 1.49989346e+00 3.62350372e+00 3.92166542e+00 1.17833540 0.72596821 798.25 2.48434646e+00 2.85231523e+00 3.78254934e+00 0.85424032 0.69362394 798.50 2.95908773e+00 2.18591680e+00 3.67891729e+00 0.63623826 0.72595056 798.75 3.69328611e+00 1.16428482e+00 3.87245677e+00 0.30538242 0.66563739 799.00 3.82789247e+00 2.22389502e-02 3.82795707e+00 0.00580965 0.66617658 799.25 3.63476590e+00 -1.78767585e+00 4.05059355e+00 -0.45708782 0.72059425 799.50 3.05590745e+00 -2.60608500e+00 4.01624817e+00 -0.70611872 0.71480762 799.75 1.66412176e+00 -3.15755642e+00 3.56923855e+00 -1.08576057 0.66608988 800.00 6.50425866e-01 -3.24946254e+00 3.31391922e+00 -1.37324295 0.73284120 800.25 1.14601540e-01 -3.05042408e+00 3.05257605e+00 -1.53324494 0.71134892 800.50 -2.88585990e-01 -2.41556005e+00 2.43273760e+00 -1.68970235 0.70483519 800.75 -4.90855390e-01 -1.98565443e+00 2.04542478e+00 -1.81313873 0.75567156 801.00 -4.52653048e-01 -1.92545609e+00 1.97794741e+00 -1.80169238 0.75280605 801.25 -4.41820158e-01 -2.11483050e+00 2.16048909e+00 -1.77674928 0.87265106 801.50 -6.59847424e-01 -2.09399927e+00 2.19550257e+00 -1.87606040 0.87510317 801.75 -8.96699978e-01 -2.15767910e+00 2.33658939e+00 -1.96466579 0.87479872 802.00 -1.29951549e+00 -2.14525808e+00 2.50816122e+00 -2.11544171 0.89637037 802.25 -1.51589045e+00 -2.03617791e+00 2.53849253e+00 -2.21075423 0.92504231 802.50 -1.67044744e+00 -1.71305105e+00 2.39268438e+00 -2.34360357 0.90266969 802.75 -1.83490777e+00 -1.55046702e+00 2.40225613e+00 -2.44001807 0.91968288 803.00 -1.90254758e+00 -1.25716220e+00 2.28038245e+00 -2.55767768 0.90734062 803.25 -1.93439019e+00 -9.43245140e-01 2.15210985e+00 -2.68789893 0.92493836 803.50 -1.73062182e+00 -5.96459917e-01 1.83052351e+00 -2.80969134 0.92086335 803.75 -1.54341046e+00 -4.64147439e-01 1.61169125e+00 -2.84946769 0.93033608 804.00 -1.40758256e+00 -3.49829239e-01 1.45040310e+00 -2.89799616 0.91134840 804.25 -1.33034564e+00 -2.57163458e-01 1.35497327e+00 -2.95064208 0.91965945 804.50 -1.24087304e+00 -1.92799342e-01 1.25576172e+00 -2.98745120 0.91622996 804.75 -1.15863504e+00 -1.54669457e-01 1.16891308e+00 -3.00888442 0.89531603 805.00 -9.33494817e-01 -2.70621138e-02 9.33887002e-01 -3.11261066 0.85371816 805.25 -8.04874018e-01 -1.97119482e-02 8.05115362e-01 -3.11710682 0.86108432 805.50 -6.34931981e-01 -1.17109349e-01 6.45641712e-01 -2.95919861 0.75214601 805.75 -5.41855719e-01 -1.51061620e-01 5.62518651e-01 -2.86971033 0.72350913 806.00 -4.19110379e-01 -3.05917832e-01 5.18882674e-01 -2.51106587 0.64921185 806.25 -3.33362172e-01 -4.55345830e-01 5.64331607e-01 -2.20274766 0.71195468 806.50 -2.24785401e-01 -6.53718862e-01 6.91286357e-01 -1.90198754 0.81665990 806.75 -2.52463170e-01 -7.97479141e-01 8.36487078e-01 -1.87739071 0.86785652 807.00 -2.47366247e-01 -9.55108362e-01 9.86621530e-01 -1.82422079 0.85729128 807.25 -1.90817148e-01 -1.09545840e+00 1.11195337e+00 -1.74325529 0.83717063 807.50 -4.08126932e-01 -1.25193253e+00 1.31677738e+00 -1.88593021 0.87730439 807.75 -4.74654543e-01 -1.34072521e+00 1.42226616e+00 -1.91105523 0.90872372 808.00 -6.41895650e-01 -1.50949631e+00 1.64030764e+00 -1.97286880 0.92760192 808.25 -7.19573056e-01 -1.49013125e+00 1.65477386e+00 -2.02066443 0.88688082 808.50 -5.89292361e-01 -1.70794640e+00 1.80675023e+00 -1.90303648 0.81512854 808.75 -7.65917432e-01 -1.91930172e+00 2.06648218e+00 -1.95049249 0.82565423 809.00 -8.56089586e-01 -2.46361158e+00 2.60811644e+00 -1.90523665 0.85655376 809.25 -9.85931110e-01 -2.68099093e+00 2.85653156e+00 -1.92319465 0.82806400 809.50 -1.64218288e+00 -3.16973970e+00 3.56987597e+00 -2.04880413 0.79168384 809.75 -2.49459671e+00 -3.59776586e+00 4.37800547e+00 -2.17706134 0.78333927 810.00 -3.85542513e+00 -3.56872067e+00 5.25357689e+00 -2.39479315 0.77092696 810.25 -5.01382032e+00 -2.93627505e+00 5.81034468e+00 -2.61180167 0.69308722 810.50 -6.24280565e+00 -1.68988649e+00 6.46748319e+00 -2.87723462 0.73733147 810.75 -6.58452610e+00 -9.12733082e-01 6.64748566e+00 -3.00385251 0.61805049 811.00 -6.41985948e+00 1.18870608e+00 6.52898291e+00 2.95850545 0.57594085 811.25 -5.31684125e+00 2.38308385e+00 5.82648174e+00 2.72022478 0.44983505 811.50 -2.23089162e+00 4.11173115e+00 4.67794939e+00 2.06791529 0.33362543 811.75 -1.08445936e+00 4.36168786e+00 4.49448252e+00 1.81448795 0.42620089 812.00 -3.55567702e-01 4.29886052e+00 4.31354033e+00 1.65332056 0.50587211 812.25 6.11667438e-01 4.45546439e+00 4.49725471e+00 1.43436440 0.51476902 812.50 1.18233322e+00 4.39741103e+00 4.55358492e+00 1.30813773 0.49928936 812.75 1.79270166e+00 3.06044592e+00 3.54684486e+00 1.04090961 0.41370232 813.00 2.15574299e+00 1.74025954e+00 2.77051098e+00 0.67915618 0.37121171 813.25 2.18565823e+00 3.68171671e-01 2.21645037e+00 0.16688222 0.32475508 813.50 2.35226106e+00 -6.52388702e-02 2.35316557e+00 -0.02772743 0.38279973 813.75 1.03645908e+00 -6.68776852e-01 1.23349499e+00 -0.57302989 0.14161952 814.00 4.65643516e-01 -1.11241350e+00 1.20593850e+00 -1.17436877 0.11958282 814.25 7.54428852e-01 -9.38977907e-01 1.20450920e+00 -0.89395070 0.16929849 814.50 1.10667159e+00 -1.30505078e+00 1.71110477e+00 -0.86746963 0.36206841 814.75 1.26318467e+00 -1.37609874e+00 1.86796233e+00 -0.82815418 0.34493805 815.00 8.49570343e-01 -1.45890056e+00 1.68824187e+00 -1.04346631 0.24354929 815.25 1.12696064e-01 -1.97948394e+00 1.98268935e+00 -1.51392568 0.31084534 815.50 -2.12418124e-01 -2.28312160e+00 2.29298184e+00 -1.66356772 0.34931354 815.75 -1.08533697e+00 -1.95832591e+00 2.23897225e+00 -2.07687118 0.50445693 816.00 -1.23141742e+00 -1.79134674e+00 2.17377827e+00 -2.17303308 0.53012215 816.25 -1.53521658e+00 -2.05175037e+00 2.56253186e+00 -2.21317474 0.52536372 816.50 -1.86695024e+00 -2.22206002e+00 2.90224980e+00 -2.26956691 0.57829704 816.75 -2.25792289e+00 -1.67654104e+00 2.81229544e+00 -2.50289935 0.59831955 817.00 -2.39678959e+00 -1.62431015e+00 2.89533829e+00 -2.54598876 0.60343394 817.25 -2.99861977e+00 -1.76016211e+00 3.47705208e+00 -2.61079369 0.65225839 817.50 -3.41727311e+00 -1.41873923e+00 3.70007790e+00 -2.74807999 0.70140436 817.75 -3.86139357e+00 -8.88434912e-01 3.96228177e+00 -2.91544694 0.76340414 818.00 -3.92066927e+00 -4.41617157e-01 3.94546236e+00 -3.02942721 0.71361817 818.25 -4.07322334e+00 2.10893147e-01 4.07867924e+00 3.08986335 0.72111931 818.50 -3.81721716e+00 5.87109713e-01 3.86210366e+00 2.98898286 0.73029752 818.75 -3.17330964e+00 1.08413937e+00 3.35339414e+00 2.81238204 0.68689555 819.00 -2.89932135e+00 8.02405673e-01 3.00830835e+00 2.87159429 0.65473906 819.25 -3.43142134e+00 6.79255466e-01 3.49800520e+00 2.94616745 0.71989932 819.50 -3.92683905e+00 1.13320765e+00 4.08708020e+00 2.86064547 0.75306583 819.75 -3.98075547e+00 2.08626103e+00 4.49431854e+00 2.65886188 0.74972543 820.00 -3.41063340e+00 2.32334282e+00 4.12678349e+00 2.54359201 0.61758714 820.25 -3.46644675e+00 4.80339083e+00 5.92358140e+00 2.19591612 0.79937069 820.50 -3.28754467e+00 5.25880143e+00 6.20184992e+00 2.12950418 0.85275316 820.75 -1.70095540e+00 5.53420848e+00 5.78970749e+00 1.86898524 0.87141472 821.00 -5.09080940e-01 5.32846722e+00 5.35273074e+00 1.66604706 0.79806291 821.25 8.19264796e-01 4.83781497e+00 4.90669425e+00 1.40304183 0.76405844 821.50 1.45672669e+00 4.60188177e+00 4.82694194e+00 1.26422584 0.75805589 821.75 1.75571756e+00 4.38753806e+00 4.72578400e+00 1.19015196 0.83939999 822.00 1.74998621e+00 4.10736857e+00 4.46463081e+00 1.16802804 0.83438387 822.25 2.07349352e+00 3.72382712e+00 4.26219002e+00 1.06273373 0.82554368 822.50 2.85364741e+00 3.31936335e+00 4.37738239e+00 0.86069940 0.82367380 822.75 3.27248584e+00 2.55530997e+00 4.15196010e+00 0.66295254 0.86417349 823.00 3.02722561e+00 1.60180077e+00 3.42488841e+00 0.48668038 0.79988372 823.25 2.46798583e+00 1.11827653e+00 2.70951960e+00 0.42543970 0.85381104 823.50 2.12013217e+00 1.09481131e+00 2.38612074e+00 0.47667208 0.87411077 823.75 1.95820818e+00 1.19980086e+00 2.29654118e+00 0.54970793 0.85470942 824.00 1.97130169e+00 1.35708334e+00 2.39326253e+00 0.60291174 0.87168695 824.25 2.08283227e+00 1.27864784e+00 2.44399889e+00 0.55057644 0.87788915 824.50 2.10515066e+00 1.10865757e+00 2.37923957e+00 0.48473216 0.90237747 824.75 2.23185071e+00 1.03166360e+00 2.45875728e+00 0.43299074 0.92298736 825.00 2.53495337e+00 1.00990716e+00 2.72871785e+00 0.37912009 0.92238957 825.25 2.62157867e+00 1.03826851e+00 2.81969435e+00 0.37709403 0.94040407 825.50 2.82087947e+00 6.40701122e-01 2.89272517e+00 0.22333912 0.92497190 825.75 2.97221995e+00 3.96216989e-01 2.99851285e+00 0.13252542 0.92991387 826.00 2.96739765e+00 -6.37431316e-02 2.96808221e+00 -0.02147785 0.89851828 826.25 2.88641292e+00 -4.39188784e-01 2.91963463e+00 -0.15099910 0.89250622 826.50 2.52710535e+00 -6.53092036e-01 2.61013231e+00 -0.25290143 0.90354073 826.75 2.39452455e+00 -6.74759334e-01 2.48777973e+00 -0.27467022 0.90335450 827.00 2.12750772e+00 -7.89739111e-01 2.26935606e+00 -0.35543842 0.87116268 827.25 2.01549385e+00 -8.08583018e-01 2.17164038e+00 -0.38152628 0.85861586 827.50 2.08607476e+00 -8.56643765e-01 2.25511562e+00 -0.38965240 0.88040878 827.75 2.12632210e+00 -9.12857709e-01 2.31399111e+00 -0.40551811 0.88973866 828.00 2.23444331e+00 -8.49280446e-01 2.39040043e+00 -0.36322209 0.85282364 828.25 2.35443386e+00 -9.20807745e-01 2.52809132e+00 -0.37280632 0.88090497 828.50 2.57026589e+00 -1.11741354e+00 2.80265584e+00 -0.41009679 0.91156215 828.75 2.71215741e+00 -1.25408133e+00 2.98806255e+00 -0.43311163 0.91812989 829.00 2.86213248e+00 -1.73333644e+00 3.34608092e+00 -0.54453439 0.89895211 829.25 2.79970434e+00 -2.03215363e+00 3.45947869e+00 -0.62786236 0.90482152 829.50 2.42792021e+00 -2.59261479e+00 3.55196397e+00 -0.81819059 0.92799459 829.75 2.35333096e+00 -2.76713227e+00 3.63251808e+00 -0.86603618 0.93920235 830.00 2.18762449e+00 -3.08099418e+00 3.77865400e+00 -0.95336484 0.93948786 830.25 2.12151521e+00 -3.16109725e+00 3.80701492e+00 -0.97970834 0.93914478 830.50 2.03975477e+00 -3.22701028e+00 3.81761639e+00 -1.00711619 0.90424122 830.75 1.92305997e+00 -3.15404972e+00 3.69407489e+00 -1.02326670 0.90573549 831.00 1.59169417e+00 -3.27533564e+00 3.64160870e+00 -1.11844069 0.92815334 831.25 1.46151736e+00 -3.42332674e+00 3.72225724e+00 -1.16729296 0.91627225 831.50 1.18847122e+00 -3.36953058e+00 3.57298197e+00 -1.23170822 0.84812609 831.75 1.05289832e+00 -3.38499746e+00 3.54496864e+00 -1.26923438 0.78696126 832.00 8.92734332e-01 -3.55028041e+00 3.66080122e+00 -1.32444910 0.74515035 832.25 9.14130193e-01 -3.56459242e+00 3.67993929e+00 -1.31975886 0.76727718 832.50 5.37616869e-01 -3.64364520e+00 3.68309411e+00 -1.42430412 0.82470397 832.75 6.66055703e-01 -3.40738197e+00 3.47187012e+00 -1.37775614 0.67535832 833.00 8.44395680e-01 -2.64564128e+00 2.77712475e+00 -1.26185115 0.55206718 833.25 7.63259615e-01 -2.90352112e+00 3.00216591e+00 -1.31373833 0.50235793 833.50 7.65143602e-01 -3.07880171e+00 3.17245405e+00 -1.32721115 0.39987067 833.75 1.21642370e+00 -2.79912768e+00 3.05201612e+00 -1.16084577 0.37026456 834.00 1.31596169e+00 -2.99058991e+00 3.26732049e+00 -1.15626084 0.42444183 834.25 1.01895913e+00 -3.59207593e+00 3.73380332e+00 -1.29438899 0.27330577 834.50 1.28834680e+00 -4.00516865e+00 4.20728100e+00 -1.25957829 0.15399204 834.75 2.16756672e-01 -4.55368637e+00 4.55884228e+00 -1.52323197 0.22999912 835.00 -5.88376431e-01 -5.50636405e+00 5.53770999e+00 -1.67724631 0.35833169 835.25 -2.28895871e+00 -2.71215777e+00 3.54896207e+00 -2.27177469 0.16448163 835.50 -3.16778896e+00 -1.06463608e+00 3.34190617e+00 -2.81737056 0.14540471 835.75 -3.86282731e+00 1.55242696e+00 4.16310753e+00 2.75945908 0.21062462 836.00 -4.42953456e+00 5.18941584e-01 4.45982923e+00 3.02496940 0.26327304 836.25 -5.51635553e+00 4.77831536e-01 5.53701195e+00 3.05518745 0.36967521 836.50 -4.73137216e+00 6.50761899e-01 4.77591599e+00 3.00490837 0.34288607 836.75 -3.79707161e+00 2.23636596e+00 4.40670915e+00 2.60932201 0.28517225 837.00 -3.86789175e+00 2.41050020e+00 4.55753199e+00 2.58428317 0.28593536 837.25 -3.61246186e+00 1.41430122e+00 3.87944953e+00 2.76842989 0.25165569 837.50 -3.19265737e+00 1.28803352e+00 3.44268666e+00 2.75812756 0.26003101 837.75 -3.25717255e+00 1.11618862e+00 3.44311633e+00 2.81144812 0.28235430 838.00 -3.35288144e+00 4.99225220e-01 3.38984362e+00 2.99378417 0.29493696 838.25 -3.04278553e+00 7.62758336e-01 3.13693227e+00 2.89597630 0.22036018 838.50 -1.80472720e+00 1.34263003e+00 2.24937672e+00 2.50197365 0.12140541 838.75 5.17647356e-02 2.16071398e+00 2.16133396e+00 1.54684367 0.12119422 839.00 2.75174895e-01 2.82874814e+00 2.84210085e+00 1.47382347 0.23322293 839.25 1.40214051e+00 3.80708507e+00 4.05707959e+00 1.21791459 0.47703146 839.50 1.11456648e+00 3.41249646e+00 3.58990119e+00 1.25510601 0.41432309 839.75 9.31337455e-01 3.21516955e+00 3.34734293e+00 1.28884353 0.50742340 840.00 1.11950894e+00 3.29956996e+00 3.48431660e+00 1.24369497 0.61362771 840.25 6.30509481e-01 1.59582349e+00 1.71586562e+00 1.19452142 0.36287695 840.50 5.32339228e-01 1.33842636e+00 1.44040626e+00 1.19224392 0.30023680 840.75 5.10087348e-01 1.38587248e+00 1.47676391e+00 1.21812189 0.38867327 841.00 1.14773371e-01 9.22966894e-01 9.30075704e-01 1.44707878 0.23888099 841.25 -8.32968455e-02 9.74014970e-01 9.77570215e-01 1.65610782 0.38607529 841.50 -4.66997180e-01 1.03819615e+00 1.13839255e+00 1.99349718 0.47081931 841.75 -8.79754411e-01 1.10692144e+00 1.41394586e+00 2.24234368 0.61389055 842.00 -1.01823002e+00 1.38482520e+00 1.71887556e+00 2.20480789 0.71606934 842.25 -1.17135672e+00 1.71359030e+00 2.07568501e+00 2.17040925 0.79028816 842.50 -1.20097763e+00 1.84826619e+00 2.20418583e+00 2.14702115 0.78048658 842.75 -1.12872382e+00 1.79495644e+00 2.12035046e+00 2.13214560 0.66473987 843.00 -1.28130235e+00 1.69124413e+00 2.12180169e+00 2.21914965 0.69226072 843.25 -1.56402856e+00 1.95559729e+00 2.50410585e+00 2.24539717 0.77995452 843.50 -1.67906624e+00 2.29671460e+00 2.84502397e+00 2.20207376 0.81029914 843.75 -1.69883781e+00 2.62915836e+00 3.13025935e+00 2.14446220 0.82346065 844.00 -1.38576770e+00 2.41806875e+00 2.78700710e+00 2.09119297 0.73845583 844.25 -1.25650418e+00 2.49438934e+00 2.79298781e+00 2.03742522 0.73016471 844.50 -1.30965596e+00 2.79382708e+00 3.08555805e+00 2.00914742 0.74458457 844.75 -9.78330748e-01 3.00295686e+00 3.15830349e+00 1.88574181 0.71196284 845.00 -3.39383280e-02 3.40091086e+00 3.40108019e+00 1.58077518 0.69904531 845.25 5.09155502e-01 3.48310805e+00 3.52012514e+00 1.42564587 0.74353844 845.50 8.79053949e-01 3.44397462e+00 3.55439123e+00 1.32088823 0.77951889 845.75 2.16192788e+00 3.41048800e+00 4.03798967e+00 1.00581851 0.75711901 846.00 2.27969941e+00 2.31588811e+00 3.24967186e+00 0.79327266 0.71660903 846.25 2.23977627e+00 1.33114157e+00 2.60548184e+00 0.53623182 0.67017052 846.50 1.88008905e+00 7.38597879e-01 2.01996576e+00 0.37432968 0.71134699 846.75 1.57704113e+00 6.80702706e-01 1.71767718e+00 0.40747526 0.71131050 847.00 9.75972391e-01 7.06077679e-01 1.20460276e+00 0.62629850 0.61786196 847.25 7.55810322e-01 7.17282620e-01 1.04199021e+00 0.75924983 0.65606000 847.50 6.40777251e-01 6.83483990e-01 9.36880916e-01 0.81763647 0.53068733 847.75 6.18231918e-01 7.23449993e-01 9.51625240e-01 0.86366050 0.51547297 848.00 5.14331954e-01 6.99816448e-01 8.68493189e-01 0.93699528 0.48650844 848.25 5.17966073e-01 6.58950742e-01 8.38155673e-01 0.90462158 0.47465580 848.50 6.14570970e-01 5.06415830e-01 7.96338163e-01 0.68921380 0.57406553 848.75 5.25825916e-01 5.20666190e-01 7.39990659e-01 0.78046771 0.59271964 849.00 3.54406708e-01 5.05967821e-01 6.17743920e-01 0.95976636 0.48652690 849.25 2.59004304e-01 4.91106326e-01 5.55219463e-01 1.08547799 0.41564834 849.50 2.95429041e-01 3.10860657e-01 4.28850401e-01 0.81084522 0.34471497 849.75 2.56457540e-01 3.15025491e-01 4.06216112e-01 0.88752576 0.34625498 850.00 1.59828011e-01 4.73077753e-01 4.99347127e-01 1.24498878 0.52915142 850.25 1.07614383e-01 4.90217682e-01 5.01890657e-01 1.35470041 0.53314903 850.50 -9.21325908e-03 3.23164663e-01 3.23295969e-01 1.59929809 0.36007665 850.75 4.23865392e-02 2.81410137e-01 2.84584405e-01 1.42129819 0.31367628 851.00 6.10028291e-02 3.20590465e-01 3.26342751e-01 1.38276151 0.26269041 851.25 -5.85501217e-02 3.03056129e-01 3.08660224e-01 1.76164393 0.20726357 851.50 -1.74165162e-01 2.74899068e-01 3.25427413e-01 2.13552776 0.22258880 851.75 -2.84960907e-01 3.76896858e-01 4.72497577e-01 2.21817177 0.35466209 852.00 -3.66723512e-01 3.41069184e-01 5.00813661e-01 2.39242417 0.46935854 852.25 -4.16632725e-01 3.08513181e-01 5.18423775e-01 2.50420452 0.38591330 852.50 -5.61964678e-01 2.90072652e-01 6.32413190e-01 2.66508819 0.44494861 852.75 -6.72403894e-01 4.62160502e-01 8.15916249e-01 2.53942365 0.57973005 853.00 -7.60156927e-01 4.78940421e-01 8.98455609e-01 2.57936678 0.68987448 853.25 -9.04848220e-01 4.08504175e-01 9.92786967e-01 2.71752397 0.69775775 853.50 -9.61124077e-01 2.39230149e-01 9.90449674e-01 2.89764331 0.68050804 853.75 -1.13769444e+00 1.85110946e-01 1.15265550e+00 2.98029900 0.68384733 854.00 -1.44200363e+00 1.51190583e-01 1.44990795e+00 3.03712676 0.72418631 854.25 -1.61899624e+00 1.20461201e-01 1.62347150e+00 3.06732464 0.66115487 854.50 -2.05340901e+00 9.08353738e-02 2.05541715e+00 3.09738510 0.73020928 854.75 -2.25787328e+00 5.16280608e-01 2.31614711e+00 2.91679929 0.64310301 855.00 -2.43869008e+00 1.05436908e+00 2.65685970e+00 2.73351251 0.68524734 855.25 -1.98659373e+00 1.12593495e+00 2.28348071e+00 2.62596802 0.64010928 855.50 -1.73508779e+00 1.06160298e+00 2.03409207e+00 2.59250985 0.53787068 855.75 -1.70892217e+00 1.25000106e+00 2.11729017e+00 2.51006584 0.57180565 856.00 -1.32689707e+00 1.43740146e+00 1.95621543e+00 2.31624020 0.47903069 856.25 -1.23594757e+00 1.67677662e+00 2.08306174e+00 2.20598846 0.47164531 856.50 -1.35925637e+00 1.77608384e+00 2.23652670e+00 2.22402463 0.49960207 856.75 -1.19775337e+00 1.32964825e+00 1.78957469e+00 2.30405583 0.35941422 857.00 -1.18959900e+00 1.67358828e+00 2.05330064e+00 2.18873884 0.41130008 857.25 -1.28795220e+00 1.80776788e+00 2.21964988e+00 2.18983214 0.37088306 857.50 -1.02709091e+00 1.95778818e+00 2.21084832e+00 2.05394382 0.35861705 857.75 -6.99573002e-01 2.16569846e+00 2.27588492e+00 1.88324014 0.41028631 858.00 -6.08333768e-01 1.91796794e+00 2.01213096e+00 1.87793567 0.45321805 858.25 -5.00179957e-01 2.01055900e+00 2.07184157e+00 1.81462319 0.47879929 858.50 -3.36530721e-01 1.76695619e+00 1.79871818e+00 1.75900016 0.44777401 858.75 -2.41248707e-01 1.53123868e+00 1.55012672e+00 1.72706314 0.46207584 859.00 -4.37352114e-01 1.67825761e+00 1.73430836e+00 1.82572530 0.59120524 859.25 -2.71065858e-01 1.76223457e+00 1.78296028e+00 1.72341952 0.60000464 859.50 -1.19685802e-01 1.83431743e+00 1.83821792e+00 1.63595211 0.64264857 859.75 -2.46872420e-01 1.91389061e+00 1.92974695e+00 1.69907782 0.77217812 860.00 -1.27280288e-01 1.85803014e+00 1.86238456e+00 1.63919229 0.73601767 860.25 -1.37237619e-01 1.83331637e+00 1.83844583e+00 1.64551455 0.70135506 860.50 -7.78161342e-02 1.65891366e+00 1.66073775e+00 1.61766985 0.70834240 860.75 1.35433961e-02 1.31132255e+00 1.31139248e+00 1.56046865 0.73109977 861.00 -2.67402077e-04 1.21742503e+00 1.21742505e+00 1.57101597 0.73183105 861.25 -1.55202138e-01 1.09833530e+00 1.10924666e+00 1.71117362 0.78766792 861.50 -2.76577543e-01 1.04375095e+00 1.07977368e+00 1.82982732 0.78049068 861.75 -4.36507567e-01 1.00577792e+00 1.09641601e+00 1.98026525 0.83541001 862.00 -4.82407947e-01 1.05228015e+00 1.15758841e+00 2.00064725 0.82565664 862.25 -7.15492566e-01 1.15122485e+00 1.35545132e+00 2.12687879 0.75802349 862.50 -9.06062469e-01 1.20494826e+00 1.50759727e+00 2.21554513 0.82076435 862.75 -8.93826680e-01 1.32846918e+00 1.60117347e+00 2.16304997 0.79264937 863.00 -9.19170447e-01 1.50252498e+00 1.76137890e+00 2.11981115 0.78982182 863.25 -9.52326678e-01 1.57765719e+00 1.84280447e+00 2.11388321 0.81574111 863.50 -7.52314388e-01 1.60242474e+00 1.77023783e+00 2.00973532 0.80358172 863.75 -6.28062320e-01 1.64158063e+00 1.75762603e+00 1.93620989 0.87274925 864.00 -5.17322350e-01 1.71788429e+00 1.79408719e+00 1.86329796 0.88276176 864.25 -4.56542375e-01 1.80173568e+00 1.85867759e+00 1.81896332 0.86797414 864.50 -3.91112476e-01 1.71909411e+00 1.76302398e+00 1.79449930 0.81879623 864.75 -3.92056429e-01 1.83188399e+00 1.87336788e+00 1.78163383 0.89183050 865.00 -3.16274919e-01 1.83611965e+00 1.86316000e+00 1.74137422 0.88974579 865.25 -1.76300264e-01 1.68766546e+00 1.69684898e+00 1.67488279 0.90790371 865.50 -1.49247658e-01 1.53062729e+00 1.53788646e+00 1.66799656 0.93089905 865.75 -1.19800653e-01 1.41743641e+00 1.42249013e+00 1.65511517 0.92238635 866.00 -1.58812532e-01 1.37777353e+00 1.38689629e+00 1.68555737 0.94347470 866.25 -1.88185579e-01 1.35028923e+00 1.36333958e+00 1.70927125 0.95906423 866.50 -2.46091926e-01 1.29235568e+00 1.31557761e+00 1.75896477 0.95205605 866.75 -2.88215438e-01 1.25546964e+00 1.28812738e+00 1.79645422 0.94255428 867.00 -2.41373636e-01 1.14697346e+00 1.17209614e+00 1.77821369 0.92293297 867.25 -2.12215264e-01 1.11732786e+00 1.13730245e+00 1.75849173 0.91714770 867.50 -2.58662407e-01 1.12020959e+00 1.14968507e+00 1.79772442 0.93892366 867.75 -2.38256697e-01 1.08705460e+00 1.11285847e+00 1.78656090 0.94650636 868.00 -2.52864020e-01 9.95861856e-01 1.02746341e+00 1.81945606 0.94793884 868.25 -2.69665903e-01 9.37656046e-01 9.75663139e-01 1.85083460 0.94153515 868.50 -3.48577939e-01 8.93485432e-01 9.59073927e-01 1.94276763 0.89293901 868.75 -3.66273049e-01 8.60924097e-01 9.35599405e-01 1.97304108 0.86756507 869.00 -4.46740274e-01 8.26606423e-01 9.39603667e-01 2.06627871 0.89327305 869.25 -4.86198095e-01 8.41919462e-01 9.72222695e-01 2.09449814 0.91526034 869.50 -4.66859171e-01 7.76893015e-01 9.06377538e-01 2.11190018 0.89173916 869.75 -4.72622795e-01 7.90188877e-01 9.20744681e-01 2.10982769 0.89035430 870.00 -4.73447522e-01 7.83271255e-01 9.15241179e-01 2.11448073 0.83018299 870.25 -4.86801619e-01 6.93665251e-01 8.47435718e-01 2.18271710 0.81247754 870.50 -4.39678709e-01 5.49278941e-01 7.03579933e-01 2.24582090 0.69641900 870.75 -5.96207981e-01 4.49137372e-01 7.46450491e-01 2.49596801 0.69904002 871.00 -6.89174089e-01 3.47344107e-01 7.71756991e-01 2.67474974 0.71482449 871.25 -6.87844252e-01 2.95297593e-01 7.48552192e-01 2.73607808 0.73043768 871.50 -9.16923702e-01 1.84122803e-01 9.35227396e-01 2.94342324 0.79464913 871.75 -1.04008280e+00 1.60168689e-01 1.05234321e+00 2.98879686 0.76337805 872.00 -1.18587998e+00 -2.00244042e-03 1.18588168e+00 -3.13990409 0.72320713 872.25 -1.40786901e+00 -8.60240572e-02 1.41049470e+00 -3.08056621 0.76991753 872.50 -1.87748391e+00 5.95721746e-02 1.87842878e+00 3.10987350 0.87262567 872.75 -2.18198979e+00 3.63437795e-01 2.21205029e+00 2.97654528 0.85437448 873.00 -2.46272768e+00 8.71141988e-01 2.61226262e+00 2.80159829 0.94484656 873.25 -2.44496592e+00 1.03777279e+00 2.65609313e+00 2.74018553 0.93035369 873.50 -2.40545086e+00 1.36370111e+00 2.76511745e+00 2.62585099 0.92074201 873.75 -2.31167444e+00 1.60859117e+00 2.81627489e+00 2.53365371 0.93940967 874.00 -2.21181210e+00 1.67770248e+00 2.77611209e+00 2.49266136 0.96025388 874.25 -2.06987478e+00 1.75475028e+00 2.71358253e+00 2.43840236 0.94445222 874.50 -2.06874016e+00 1.82796782e+00 2.76064344e+00 2.41790469 0.95250760 874.75 -2.23870500e+00 1.76023347e+00 2.84784514e+00 2.47527801 0.92293056 875.00 -2.58766850e+00 1.87986129e+00 3.19842253e+00 2.51332216 0.93496829 875.25 -2.69548855e+00 2.39112012e+00 3.60320884e+00 2.41596043 0.91548463 875.50 -2.58695524e+00 2.84742003e+00 3.84709478e+00 2.30830203 0.94363446 875.75 -2.34407630e+00 3.26450845e+00 4.01891890e+00 2.19353314 0.94447867 876.00 -2.14147498e+00 3.69014048e+00 4.26650347e+00 2.09662210 0.95061447 876.25 -1.77835525e+00 3.99948617e+00 4.37703519e+00 1.98918889 0.93954867 876.50 -1.07820695e+00 4.14458346e+00 4.28253456e+00 1.82530343 0.94420477 876.75 -4.53788825e-01 4.41354015e+00 4.43680751e+00 1.67325372 0.94962813 877.00 -2.17013225e-01 4.45106620e+00 4.45635334e+00 1.61951309 0.96254921 877.25 4.14969783e-01 4.02977642e+00 4.05108602e+00 1.46818213 0.94437881 877.50 6.95952810e-01 3.96077860e+00 4.02145713e+00 1.39686076 0.93000252 877.75 8.11240077e-01 3.42028375e+00 3.51517445e+00 1.33791471 0.88347438 878.00 8.95380223e-01 3.36750396e+00 3.48450695e+00 1.31092068 0.91164786 878.25 8.98708200e-01 3.36284075e+00 3.48085827e+00 1.30965246 0.87908849 878.50 1.01709647e+00 3.16616154e+00 3.32551713e+00 1.25996933 0.89571959 878.75 1.43609347e+00 2.92040421e+00 3.25440089e+00 1.11377469 0.92530404 879.00 1.61727237e+00 2.86542080e+00 3.29032009e+00 1.05695707 0.92628799 879.25 1.80177240e+00 2.43403566e+00 3.02835159e+00 0.93357045 0.91803661 879.50 1.96469055e+00 2.34684911e+00 3.06067145e+00 0.87380335 0.92820737 879.75 2.03635086e+00 2.10191033e+00 2.92655973e+00 0.80123911 0.91232563 880.00 2.16437306e+00 2.08085454e+00 3.00241009e+00 0.76572719 0.91985031 880.25 2.27378024e+00 1.93722635e+00 2.98712613e+00 0.70564525 0.93896680 880.50 2.46591381e+00 1.93194754e+00 3.13259512e+00 0.66457458 0.93536447 880.75 3.03296358e+00 2.06608985e+00 3.66982225e+00 0.59800466 0.91845046 881.00 3.28010802e+00 1.94096109e+00 3.81135653e+00 0.53432157 0.90921150 881.25 3.58185024e+00 1.65547564e+00 3.94591570e+00 0.43294023 0.85461943 881.50 4.07273441e+00 1.98046816e+00 4.52873268e+00 0.45260729 0.78474145 881.75 4.77102042e+00 2.17006625e+00 5.24135701e+00 0.42687424 0.67277796 882.00 4.45258196e+00 3.24024991e+00 5.50678723e+00 0.62909126 0.58725642 882.25 3.83461636e+00 5.01996185e+00 6.31698501e+00 0.91847508 0.62276116 882.50 2.40751109e+00 5.56844080e+00 6.06660058e+00 1.16271732 0.61231446 882.75 4.96217008e-01 5.87099792e+00 5.89193074e+00 1.48647668 0.69556456 883.00 -1.84060358e-01 5.18011280e+00 5.18338180e+00 1.60631350 0.76483852 883.25 -1.46898836e-01 4.32822374e+00 4.33071588e+00 1.60472305 0.82347958 883.50 -1.59162279e-01 4.16542703e+00 4.16846674e+00 1.60898806 0.85408692 883.75 -4.05942243e-02 3.68679147e+00 3.68701495e+00 1.58180660 0.89603777 884.00 -2.72033985e-02 3.33849546e+00 3.33860629e+00 1.57894455 0.85260090 884.25 1.19352550e-01 2.91716330e+00 2.91960387e+00 1.52990523 0.82867979 884.50 1.83800503e-01 2.58680513e+00 2.59332670e+00 1.49986245 0.80610568 884.75 8.27540694e-02 2.45000690e+00 2.45140410e+00 1.53703209 0.78809828 885.00 -8.69702659e-02 2.42441929e+00 2.42597872e+00 1.60665357 0.77013913 885.25 -3.43563473e-02 2.30260751e+00 2.30286381e+00 1.58571585 0.68115928 885.50 4.53199755e-02 2.17115246e+00 2.17162541e+00 1.54992566 0.65217553 885.75 -6.93796462e-02 2.05545827e+00 2.05662885e+00 1.60453737 0.57275331 886.00 -1.47585032e-01 1.91852335e+00 1.92419156e+00 1.64757149 0.41350084 886.25 3.57972116e-02 2.00315075e+00 2.00347058e+00 1.55292778 0.33724105 886.50 6.04229481e-01 2.56798748e+00 2.63811542e+00 1.33970672 0.57631777 886.75 8.01278617e-01 2.91025052e+00 3.01854361e+00 1.30212355 0.68643096 887.00 1.44497739e+00 2.28579277e+00 2.70422045e+00 1.00706774 0.72141244 887.25 1.60828823e+00 1.73894533e+00 2.36865402e+00 0.82441271 0.76123836 887.50 1.35199741e+00 1.45121726e+00 1.98341335e+00 0.82077842 0.66907088 887.75 1.21680004e+00 1.34906422e+00 1.81674891e+00 0.83690019 0.59156677 888.00 6.99510791e-01 1.38893174e+00 1.55513559e+00 1.10424716 0.42265523 888.25 3.72908784e-01 1.27408600e+00 1.32753761e+00 1.28606187 0.35828389 888.50 5.67412846e-01 1.22590717e+00 1.35085371e+00 1.13730672 0.38023438 888.75 8.80280237e-01 1.45148869e+00 1.69756082e+00 1.02563512 0.40403302 889.00 1.42879363e+00 1.79236631e+00 2.29216671e+00 0.89779260 0.54121654 889.25 1.29150128e+00 1.62652554e+00 2.07691138e+00 0.89970956 0.48456868 889.50 1.05135060e+00 1.21468428e+00 1.60648560e+00 0.85735279 0.25487289 889.75 7.57015838e-01 4.25128812e-01 8.68220874e-01 0.51169419 0.06659209 890.00 -6.25293355e-02 -1.55224012e-01 1.67345187e-01 -1.95374245 0.00137973 890.25 -1.34540538e-01 -1.26498570e+00 1.27212027e+00 -1.67675535 0.07545451 890.50 -9.22969957e-01 -2.13261570e+00 2.32377349e+00 -1.97924474 0.31866837 890.75 -1.45349803e+00 -2.10435541e+00 2.55753166e+00 -2.17525973 0.54300775 891.00 -1.27052467e+00 -1.54171784e+00 1.99778047e+00 -2.26005869 0.70251502 891.25 -1.05356492e+00 -1.48286330e+00 1.81903343e+00 -2.18853033 0.77687149 891.50 -9.82134292e-01 -1.05388519e+00 1.44057688e+00 -2.32096830 0.73792672 891.75 -7.72892521e-01 -8.56385819e-01 1.15358551e+00 -2.30499371 0.65155646 892.00 -5.42106056e-01 -7.75373335e-01 9.46088148e-01 -2.18095488 0.60266846 892.25 -5.85858858e-01 -7.64079988e-01 9.62833749e-01 -2.22493197 0.55165889 892.50 -6.67939220e-01 -8.89660104e-01 1.11249175e+00 -2.21479660 0.60177750 892.75 -7.84802309e-01 -8.40400193e-01 1.14986397e+00 -2.32199801 0.61435128 893.00 -1.14051609e+00 -6.23300389e-01 1.29972318e+00 -2.64143492 0.60369739 893.25 -1.09580732e+00 -6.37447413e-01 1.26772745e+00 -2.61472661 0.60837433 893.50 -1.30034966e+00 -5.68546554e-01 1.41920908e+00 -2.72941230 0.76988798 893.75 -1.38944385e+00 -4.76793990e-01 1.46897472e+00 -2.81102919 0.84747842 894.00 -1.40660153e+00 -4.09596272e-01 1.46502456e+00 -2.85823267 0.90767721 894.25 -1.38010426e+00 -3.82897617e-01 1.43223544e+00 -2.87095841 0.89388398 894.50 -1.40063668e+00 -3.21303828e-01 1.43701749e+00 -2.91609570 0.92408329 894.75 -1.37665950e+00 -2.51489716e-01 1.39944219e+00 -2.96090394 0.92738418 895.00 -1.35648513e+00 -2.22344328e-01 1.37458681e+00 -2.97912528 0.94140690 895.25 -1.29821500e+00 -2.27260701e-01 1.31795660e+00 -2.96829237 0.92381368 895.50 -1.35007029e+00 -2.18872452e-01 1.36769695e+00 -2.98087168 0.94944038 895.75 -1.36161676e+00 -1.74663469e-01 1.37277366e+00 -3.01401285 0.94170903 896.00 -1.46065728e+00 -1.01954978e-01 1.46421122e+00 -3.07190493 0.93438552 896.25 -1.52716024e+00 1.12843143e-02 1.52720193e+00 3.13420370 0.91793655 896.50 -1.49106079e+00 4.41566924e-02 1.49171448e+00 3.11198703 0.91014084 896.75 -1.47610969e+00 1.05251817e-01 1.47985735e+00 3.07040961 0.85098309 897.00 -1.41287795e+00 2.38968630e-01 1.43294456e+00 2.97404228 0.76683684 897.25 -1.23233942e+00 3.55333041e-01 1.28254513e+00 2.86086692 0.77850439 897.50 -1.23555406e+00 3.26196209e-01 1.27788803e+00 2.88347402 0.78651894 897.75 -1.25843073e+00 3.26253783e-01 1.30003439e+00 2.88792305 0.70433793 898.00 -1.08551741e+00 3.58228988e-01 1.14309932e+00 2.82283825 0.65852679 898.25 -9.66861648e-01 4.04998908e-01 1.04825835e+00 2.74491719 0.65673560 898.50 -9.50464170e-01 4.20021876e-01 1.03913450e+00 2.72548472 0.66830957 898.75 -9.27976499e-01 4.19949517e-01 1.01857645e+00 2.71662576 0.70466457 899.00 -8.50161883e-01 3.74541458e-01 9.29008359e-01 2.72662248 0.74921702 899.25 -7.48809125e-01 3.03127460e-01 8.07837461e-01 2.75694428 0.68533439 899.50 -7.41835063e-01 3.87399745e-01 8.36897738e-01 2.66032891 0.71255793 899.75 -6.05600757e-01 3.86835111e-01 7.18605371e-01 2.57315780 0.71461167 900.00 -5.82062888e-01 3.45045513e-01 6.76648810e-01 2.60648583 0.67752447 900.25 -5.71740279e-01 3.53175954e-01 6.72026934e-01 2.58824484 0.74941486 900.50 -6.19824298e-01 3.30711410e-01 7.02532702e-01 2.65146144 0.77838133 900.75 -6.84361783e-01 2.24637192e-01 7.20286691e-01 2.82443007 0.82415642 901.00 -6.54568413e-01 2.56394642e-01 7.02992190e-01 2.76826160 0.83236163 901.25 -6.57754083e-01 3.08975972e-01 7.26709423e-01 2.70244155 0.82668662 901.50 -6.24633637e-01 2.93387673e-01 6.90103982e-01 2.70248112 0.78036620 901.75 -5.20925409e-01 3.78311244e-01 6.43803292e-01 2.51347923 0.76079270 902.00 -5.32962248e-01 4.05596477e-01 6.69744175e-01 2.49107413 0.79927205 902.25 -5.04414898e-01 3.46386337e-01 6.11896955e-01 2.53984251 0.84552519 902.50 -4.85939901e-01 3.34704022e-01 5.90054548e-01 2.53843897 0.83738936 902.75 -4.48293461e-01 3.61328369e-01 5.75782265e-01 2.46319867 0.85558794 903.00 -4.66204677e-01 3.37296124e-01 5.75426343e-01 2.51527253 0.88235533 903.25 -4.57977501e-01 3.08824844e-01 5.52373222e-01 2.54830810 0.90068824 903.50 -4.48632095e-01 3.26213254e-01 5.54694370e-01 2.51289060 0.90785302 903.75 -4.37604761e-01 3.13279277e-01 5.38183828e-01 2.52027804 0.94948261 904.00 -4.34694196e-01 3.00273179e-01 5.28320950e-01 2.53708904 0.95353600 904.25 -4.25424686e-01 2.91141021e-01 5.15508736e-01 2.54144483 0.92797318 904.50 -4.27296902e-01 2.73146253e-01 5.07140531e-01 2.57281718 0.93706527 904.75 -4.07163177e-01 2.32391084e-01 4.68814962e-01 2.62295322 0.95104449 905.00 -4.23134104e-01 2.25475470e-01 4.79459755e-01 2.65199612 0.95276581 905.25 -4.32919785e-01 2.22556516e-01 4.86776071e-01 2.66674256 0.96754623 905.50 -4.29271348e-01 2.13130517e-01 4.79268722e-01 2.68075402 0.97773914 905.75 -4.21625624e-01 2.01145608e-01 4.67148501e-01 2.69645544 0.98106589 906.00 -4.13194015e-01 1.90922623e-01 4.55171113e-01 2.70875063 0.98065718 906.25 -4.22401990e-01 1.90595230e-01 4.63411246e-01 2.71772660 0.98573098 906.50 -4.28198698e-01 1.84762698e-01 4.66359710e-01 2.73423928 0.97606053 906.75 -4.24921976e-01 1.76086870e-01 4.59962250e-01 2.74873605 0.97368150 907.00 -4.19344891e-01 1.73301295e-01 4.53743844e-01 2.74970201 0.97384002 907.25 -4.28147503e-01 1.72906341e-01 4.61743313e-01 2.75777379 0.97791157 907.50 -4.21413116e-01 1.72463627e-01 4.55338025e-01 2.75313703 0.96896797 907.75 -4.14309240e-01 1.71861551e-01 4.48540454e-01 2.74838060 0.95299237 908.00 -3.83794959e-01 1.55045095e-01 4.13929405e-01 2.75766084 0.93804759 908.25 -3.66452033e-01 1.40548604e-01 3.92480576e-01 2.77535693 0.93755278 908.50 -3.41550426e-01 1.35489164e-01 3.67442522e-01 2.76394418 0.90635175 908.75 -3.15616899e-01 1.33085837e-01 3.42528636e-01 2.74254684 0.86977372 909.00 -2.70741779e-01 1.22220378e-01 2.97050385e-01 2.71755196 0.76895152 909.25 -2.57042304e-01 8.40771308e-02 2.70443543e-01 2.82546749 0.74795369 909.50 -2.34249671e-01 9.34885110e-02 2.52216197e-01 2.76186434 0.80958947 909.75 -2.25387063e-01 8.55889363e-02 2.41090842e-01 2.77867110 0.82495774 910.00 -2.11184497e-01 3.54326475e-02 2.14136322e-01 2.97536041 0.75723682 910.25 -2.05065946e-01 6.02889611e-03 2.05154551e-01 3.11220133 0.72054877 910.50 -1.90031787e-01 -3.86081202e-02 1.93914071e-01 -2.94115411 0.76433315 910.75 -1.75747168e-01 -3.78152026e-02 1.79769454e-01 -2.92965573 0.68262943 911.00 -1.39673356e-01 -6.28757181e-02 1.53173112e-01 -2.71860354 0.55964850 911.25 -1.11696384e-01 -8.55490409e-02 1.40693712e-01 -2.48798856 0.52280664 911.50 -6.20554662e-02 -1.65043905e-01 1.76324619e-01 -1.93043789 0.56884941 911.75 -5.71422718e-02 -2.16303222e-01 2.23723765e-01 -1.82907263 0.64705724 912.00 -6.23312179e-02 -2.79895886e-01 2.86752311e-01 -1.78991509 0.76994391 912.25 -8.58004124e-02 -3.25446110e-01 3.36566310e-01 -1.82857029 0.83689041 912.50 -9.83689435e-02 -3.75663258e-01 3.88328897e-01 -1.82690025 0.87395479 912.75 -1.30571044e-01 -4.06201977e-01 4.26671822e-01 -1.88180827 0.88441521 913.00 -1.70992649e-01 -4.16305116e-01 4.50053814e-01 -1.96052584 0.90926340 913.25 -1.69882922e-01 -4.26340552e-01 4.58940599e-01 -1.94998102 0.88899229 913.50 -1.59949958e-01 -4.40403434e-01 4.68550076e-01 -1.91917271 0.87399188 913.75 -1.86353092e-01 -4.78648640e-01 5.13645788e-01 -1.94207220 0.86431875 914.00 -2.83711667e-01 -5.97921167e-01 6.61817219e-01 -2.01383400 0.89533323 914.25 -3.23239587e-01 -6.11028155e-01 6.91259168e-01 -2.05738116 0.90717560 914.50 -4.28674516e-01 -6.17929214e-01 7.52062733e-01 -2.17730017 0.92624459 914.75 -5.07239698e-01 -6.32294100e-01 8.10609610e-01 -2.24689016 0.92504898 915.00 -6.45008518e-01 -5.76324687e-01 8.64977534e-01 -2.41237209 0.93533927 915.25 -7.50779682e-01 -4.60333600e-01 8.80668584e-01 -2.59156684 0.91583234 915.50 -8.61114209e-01 -3.82763866e-01 9.42351239e-01 -2.72332329 0.93315007 915.75 -8.67834994e-01 -3.05739308e-01 9.20116353e-01 -2.80286924 0.91230898 916.00 -9.23238169e-01 -1.00397934e-01 9.28681034e-01 -3.03327286 0.91220412 916.25 -8.74145078e-01 7.58953017e-02 8.77433596e-01 3.05498751 0.90441289 916.50 -9.22368038e-01 2.39525798e-01 9.52961387e-01 2.88751901 0.91010659 916.75 -8.98788691e-01 4.67266565e-01 1.01299514e+00 2.66216406 0.87892262 917.00 -8.64379926e-01 6.78536047e-01 1.09889209e+00 2.47606678 0.92050787 917.25 -7.60690265e-01 8.52008332e-01 1.14217681e+00 2.29963051 0.88932798 917.50 -6.34430600e-01 9.97955119e-01 1.18254666e+00 2.13707484 0.92641217 917.75 -5.23212562e-01 1.09563988e+00 1.21415737e+00 2.01631555 0.92009000 918.00 -4.62357007e-01 1.17416315e+00 1.26191644e+00 1.94592551 0.91413117 918.25 -3.56226277e-01 1.29314686e+00 1.34131501e+00 1.83960168 0.89012568 918.50 -2.36404975e-01 1.37194738e+00 1.39216627e+00 1.74143408 0.89407926 918.75 -2.68427662e-01 1.45191725e+00 1.47652196e+00 1.75361020 0.89578001 919.00 -3.26860917e-01 1.50056943e+00 1.53575606e+00 1.78527070 0.88613198 919.25 -4.43307120e-01 1.46355045e+00 1.52921585e+00 1.86491010 0.84446557 919.50 -5.49007619e-01 1.46419484e+00 1.56373779e+00 1.92952781 0.80645924 919.75 -8.74168510e-01 1.39106713e+00 1.64293589e+00 2.13184815 0.63497559 920.00 -8.49015179e-01 1.38486837e+00 1.62440363e+00 2.12076755 0.48818743 920.25 -1.05979002e+00 1.39299401e+00 1.75031060e+00 2.22117376 0.41913110 920.50 -9.34078932e-01 1.59980194e+00 1.85253062e+00 2.09927230 0.50134056 920.75 -8.11834578e-01 1.59872898e+00 1.79304482e+00 2.04066445 0.49469744 921.00 -6.41606423e-01 1.31364810e+00 1.46196106e+00 2.02513366 0.33797008 921.25 -2.05403127e-01 7.88771933e-01 8.15077669e-01 1.82554723 0.11095925 921.50 -1.02088510e-01 6.12590945e-01 6.21039234e-01 1.73592915 0.07157541 921.75 -3.63651023e-01 7.01531551e-01 7.90182627e-01 2.04902958 0.16935681 922.00 -4.15330410e-01 9.41591246e-01 1.02912265e+00 1.98621953 0.28454264 922.25 -6.83269437e-01 8.13694378e-01 1.06252325e+00 2.26928763 0.40705644 922.50 -8.59377017e-01 7.51336321e-01 1.14150564e+00 2.42317047 0.47133184 922.75 -1.25020627e+00 7.21760833e-01 1.44359080e+00 2.61802153 0.58753010 923.00 -1.52225612e+00 5.15527880e-01 1.60718159e+00 2.81505542 0.63472738 923.25 -1.67491820e+00 2.09265014e-01 1.68794040e+00 3.01729630 0.68712043 923.50 -1.54364937e+00 2.28196047e-01 1.56042520e+00 2.99482667 0.64189725 923.75 -1.27250566e+00 2.42887975e-01 1.29547876e+00 2.95298750 0.64332437 924.00 -1.26997806e+00 1.95424941e-01 1.28492614e+00 2.98890971 0.70848753 924.25 -1.39325547e+00 1.90447431e-01 1.40621158e+00 3.00574219 0.83259078 924.50 -1.37502349e+00 1.48664933e-01 1.38303683e+00 3.03389290 0.83789574 924.75 -1.36547843e+00 1.89579533e-02 1.36561003e+00 3.12770980 0.79901960 925.00 -1.44179022e+00 -1.29161107e-01 1.44756404e+00 -3.05224731 0.83320246 925.25 -1.45821265e+00 -4.00357475e-01 1.51217401e+00 -2.87364154 0.85941131 925.50 -1.40806251e+00 -4.72408805e-01 1.48519700e+00 -2.81789092 0.83857605 925.75 -1.40740123e+00 -4.61625298e-01 1.48117390e+00 -2.82465123 0.77541072 926.00 -1.48647883e+00 -5.92615964e-01 1.60025404e+00 -2.76223251 0.78561533 926.25 -1.56284629e+00 -8.08141206e-01 1.75942625e+00 -2.66436215 0.80776289 926.50 -1.59369236e+00 -9.46705023e-01 1.85367358e+00 -2.60557259 0.74147592 926.75 -1.46568189e+00 -8.80432950e-01 1.70979109e+00 -2.60065969 0.73153916 927.00 -1.35009409e+00 -7.27835454e-01 1.53378568e+00 -2.64715662 0.55161427 927.25 -1.45314652e+00 -6.15494452e-01 1.57812174e+00 -2.74094250 0.47840021 927.50 -1.42954085e+00 -7.45674190e-01 1.61233279e+00 -2.66080062 0.55382704 927.75 -1.40845856e+00 -7.33118684e-01 1.58783454e+00 -2.66167092 0.46781590 928.00 -1.57396324e+00 -5.12206983e-01 1.65520883e+00 -2.82697641 0.45777702 928.25 -1.58612645e+00 -4.65976135e-01 1.65315785e+00 -2.85584974 0.46401342 928.50 -1.73788719e+00 -1.60417392e-01 1.74527523e+00 -3.04954750 0.37681755 928.75 -1.88074435e+00 -5.45008488e-02 1.88153385e+00 -3.11262242 0.38772668 929.00 -1.36092273e+00 5.14176884e-01 1.45481564e+00 2.78035641 0.28645288 929.25 -9.25137238e-01 9.58829460e-01 1.33237864e+00 2.33831274 0.26598167 929.50 -1.26538692e+00 1.25834725e+00 1.78455648e+00 2.35898387 0.45491266 929.75 -1.46325138e+00 1.13610764e+00 1.85252400e+00 2.48139177 0.50130886 930.00 -7.74773502e-01 9.86656206e-01 1.25449769e+00 2.23647951 0.25697307 930.25 -6.52343942e-01 9.61076676e-01 1.16155973e+00 2.16712709 0.25232171 930.50 -9.58806595e-01 8.38060519e-01 1.27344239e+00 2.42329173 0.28049812 930.75 -1.08985878e+00 9.17880487e-01 1.42488482e+00 2.44164359 0.30422424 931.00 -2.89165992e-01 1.10339244e+00 1.14065413e+00 1.82710228 0.28090419 931.25 -1.28525398e-01 1.13928990e+00 1.14651657e+00 1.68313323 0.25564238 931.50 -3.29318076e-01 1.16749350e+00 1.21305048e+00 1.84572603 0.27309920 931.75 -2.47183734e-01 1.25720453e+00 1.28127398e+00 1.76493380 0.37612539 932.00 -3.31251770e-01 1.14532342e+00 1.19226401e+00 1.85233518 0.41518041 932.25 -2.63158826e-01 8.98680006e-01 9.36417813e-01 1.85566055 0.28911868 932.50 -4.16434128e-01 9.89696244e-01 1.07373928e+00 1.96907837 0.38806708 932.75 -4.12940542e-01 1.09485072e+00 1.17013588e+00 1.93146466 0.36139560 933.00 1.77535741e-02 1.24527294e+00 1.24539949e+00 1.55654052 0.39661834 933.25 -1.10854277e-03 1.17961988e+00 1.17962040e+00 1.57173607 0.40669661 933.50 -1.08787095e-01 7.88488016e-01 7.95957275e-01 1.70790000 0.22672631 933.75 -2.43162835e-01 6.26625377e-01 6.72151417e-01 1.94095991 0.13956565 934.00 8.06262723e-02 6.67316160e-01 6.72169215e-01 1.45055745 0.12533788 934.25 -3.79493008e-02 5.77091646e-01 5.78338064e-01 1.63646136 0.10080696 934.50 -2.35458420e-01 1.97040577e-01 3.07027127e-01 2.44478955 0.03843234 934.75 -2.09160962e-01 1.00272619e-01 2.31954534e-01 2.69455712 0.01457401 935.00 2.40765627e-01 1.52561262e-01 2.85031623e-01 0.56479574 0.01462191 935.25 3.99310995e-01 4.50828482e-01 6.02242136e-01 0.84592301 0.05262575 935.50 3.37533486e-01 5.07114519e-01 6.09174844e-01 0.98353520 0.04928589 935.75 6.49939230e-01 3.78980093e-01 7.52360893e-01 0.52790094 0.07252396 936.00 9.83999240e-01 6.15651283e-01 1.16072435e+00 0.55907547 0.12850371 936.25 9.98802590e-01 7.60583810e-01 1.25542596e+00 0.65081781 0.16858520 936.50 1.44244985e+00 9.25790990e-01 1.71398674e+00 0.57060220 0.25720086 936.75 1.53845890e+00 1.23027730e+00 1.96988274e+00 0.67454678 0.36048758 937.00 1.81527148e+00 1.40332052e+00 2.29445397e+00 0.65809923 0.38403837 937.25 2.03229940e+00 1.33467083e+00 2.43137555e+00 0.58109139 0.46535418 937.50 2.17722827e+00 8.90921052e-01 2.35245898e+00 0.38841187 0.43519404 937.75 2.19002493e+00 1.13231418e+00 2.46542990e+00 0.47718062 0.43936797 938.00 2.10659566e+00 1.30874855e+00 2.48003388e+00 0.55590704 0.45540388 938.25 1.87160733e+00 1.52754759e+00 2.41584677e+00 0.68452253 0.49470741 938.50 2.04752792e+00 1.54528342e+00 2.56520397e+00 0.64650672 0.44971628 938.75 1.76272259e+00 1.47676833e+00 2.29957292e+00 0.69735500 0.31816695 939.00 1.93750885e+00 1.91195237e+00 2.72204012e+00 0.77875928 0.41609122 939.25 2.26268124e+00 1.49000090e+00 2.70921189e+00 0.58233523 0.53678349 939.50 2.57184910e+00 1.52144998e+00 2.98817969e+00 0.53420402 0.60395677 939.75 2.29035040e+00 2.39978691e+00 3.31733058e+00 0.80872726 0.45731257 940.00 1.57118500e+00 2.86167084e+00 3.26462591e+00 1.06868690 0.33998911 940.25 2.46396821e+00 2.02698834e+00 3.19058319e+00 0.68840133 0.37384123 940.50 3.39021040e+00 1.20850240e+00 3.59916721e+00 0.34242553 0.45547034 940.75 3.79738465e+00 7.33608960e-01 3.86759774e+00 0.19083701 0.44760460 941.00 4.36103270e+00 6.54707525e-01 4.40990342e+00 0.14901387 0.49306967 941.25 4.88049482e+00 1.12543333e+00 5.00857564e+00 0.22663646 0.62657742 941.50 5.19559451e+00 1.13835339e+00 5.31883923e+00 0.21569144 0.71067305 941.75 5.46885466e+00 1.28901025e+00 5.61871149e+00 0.23147543 0.79033412 942.00 5.60597853e+00 1.05483316e+00 5.70435520e+00 0.18598757 0.83767766 942.25 5.37829894e+00 1.12591855e+00 5.49488781e+00 0.20636452 0.89967565 942.50 5.22947461e+00 1.18617218e+00 5.36231378e+00 0.22305021 0.87229939 942.75 5.43828457e+00 8.08128585e-01 5.49800062e+00 0.14752038 0.81914055 943.00 5.39763819e+00 4.36455262e-01 5.41525541e+00 0.08068487 0.82814818 943.25 5.47678037e+00 6.28462554e-01 5.51272060e+00 0.11425064 0.87473891 943.50 5.53811390e+00 4.77404438e-01 5.55865276e+00 0.08599085 0.90708192 943.75 5.75870938e+00 8.15046768e-01 5.81610135e+00 0.14059904 0.94257080 944.00 5.93367597e+00 6.66324841e-01 5.97097139e+00 0.11182697 0.93133262 944.25 6.36522806e+00 6.86246046e-02 6.36559798e+00 0.01078075 0.92509633 944.50 6.55615282e+00 -3.02620174e-01 6.56313330e+00 -0.04612545 0.92041009 944.75 6.36352313e+00 -1.10333011e+00 6.45846452e+00 -0.17167680 0.88604939 945.00 6.28221137e+00 -1.55775996e+00 6.47246443e+00 -0.24306117 0.90501335 945.25 6.04227854e+00 -2.00185347e+00 6.36526097e+00 -0.31992639 0.92900082 945.50 5.81697205e+00 -2.11382451e+00 6.18913709e+00 -0.34855264 0.92679736 945.75 5.65225128e+00 -2.28386378e+00 6.09622656e+00 -0.38400377 0.94850368 946.00 5.42083322e+00 -2.46667916e+00 5.95566444e+00 -0.42703471 0.93469603 946.25 4.93571058e+00 -2.85137391e+00 5.70013790e+00 -0.52386315 0.93764482 946.50 4.63059555e+00 -2.71741951e+00 5.36905802e+00 -0.53068696 0.92750090 946.75 4.09186044e+00 -2.67099125e+00 4.88646254e+00 -0.57831104 0.91946149 947.00 3.95545079e+00 -2.37124704e+00 4.61176793e+00 -0.54004327 0.93999228 947.25 3.90842591e+00 -2.24993809e+00 4.50976879e+00 -0.52233276 0.94553238 947.50 3.83735766e+00 -2.22506448e+00 4.43578919e+00 -0.52546621 0.93950165 947.75 3.68368337e+00 -2.23222490e+00 4.30724404e+00 -0.54480227 0.93738422 948.00 3.56888818e+00 -2.30762413e+00 4.24995199e+00 -0.57397760 0.90935840 948.25 3.67172684e+00 -2.40729816e+00 4.39051961e+00 -0.58032361 0.93865030 948.50 3.52768749e+00 -2.76682081e+00 4.48328857e+00 -0.66510393 0.93427244 948.75 3.49217892e+00 -3.13418068e+00 4.69237703e+00 -0.73142425 0.93543186 949.00 3.39411599e+00 -2.79957508e+00 4.39973227e+00 -0.68970000 0.92886694 949.25 3.13986283e+00 -2.69681579e+00 4.13902814e+00 -0.70963606 0.91774719 949.50 2.75890191e+00 -2.71498563e+00 3.87074756e+00 -0.77737547 0.89635029 949.75 2.39013126e+00 -2.84043752e+00 3.71225171e+00 -0.87127767 0.88146519 950.00 1.98610436e+00 -2.62381384e+00 3.29074606e+00 -0.92285998 0.83116675 950.25 1.89216388e+00 -2.50607581e+00 3.14017517e+00 -0.92408341 0.83197757 950.50 1.63950058e+00 -1.96169372e+00 2.55660016e+00 -0.87462900 0.75973253 950.75 1.36305137e+00 -1.85977322e+00 2.30578955e+00 -0.93832110 0.79428757 951.00 1.47632291e+00 -1.71792111e+00 2.26512301e+00 -0.86088991 0.84554610 951.25 1.57100107e+00 -1.57626668e+00 2.22545748e+00 -0.78707124 0.85858700 951.50 1.70921484e+00 -1.31522740e+00 2.15667301e+00 -0.65585982 0.83002136 951.75 1.71328684e+00 -1.15230470e+00 2.06474161e+00 -0.59207815 0.81566606 952.00 1.79029867e+00 -9.85823626e-01 2.04377531e+00 -0.50334026 0.85342788 952.25 1.93167968e+00 -9.30812313e-01 2.14424764e+00 -0.44903610 0.89577112 952.50 1.94519226e+00 -1.00965577e+00 2.19161532e+00 -0.47877272 0.87994174 952.75 2.07814121e+00 -1.05692305e+00 2.33147104e+00 -0.47049643 0.89571674 953.00 2.43143578e+00 -1.02777016e+00 2.63973321e+00 -0.39992170 0.92802808 953.25 2.43933538e+00 -1.10940536e+00 2.67976442e+00 -0.42683695 0.93235864 953.50 2.50738793e+00 -1.22742221e+00 2.79169474e+00 -0.45523034 0.92753738 953.75 2.61316342e+00 -1.22482063e+00 2.88596754e+00 -0.43830527 0.93525778 954.00 2.50980462e+00 -1.20190396e+00 2.78274907e+00 -0.44661213 0.94180354 954.25 2.49244868e+00 -1.31161761e+00 2.81649448e+00 -0.48441588 0.93881683 954.50 2.54419734e+00 -1.43579076e+00 2.92137557e+00 -0.51378564 0.91591727 954.75 2.62850674e+00 -1.39638796e+00 2.97639833e+00 -0.48833210 0.90816961 955.00 2.45654804e+00 -1.33114506e+00 2.79402496e+00 -0.49658479 0.85969294 955.25 2.30760999e+00 -1.27696348e+00 2.63736604e+00 -0.50542731 0.84990761 955.50 2.45905769e+00 -1.51741614e+00 2.88955298e+00 -0.55287810 0.84945929 955.75 2.51595440e+00 -1.69148858e+00 3.03169262e+00 -0.59189588 0.84311713 956.00 2.45504615e+00 -1.39166793e+00 2.82205443e+00 -0.51569548 0.74479258 956.25 2.38393312e+00 -1.38335711e+00 2.75623185e+00 -0.52579592 0.65601804 956.50 2.52824858e+00 -1.99995551e+00 3.22364125e+00 -0.66925597 0.67214496 956.75 2.15869957e+00 -2.08642780e+00 3.00219333e+00 -0.76837517 0.62694294 957.00 1.94654042e+00 -1.99513354e+00 2.78739618e+00 -0.79772558 0.58891794 957.25 2.11974197e+00 -1.62349789e+00 2.67002836e+00 -0.65359598 0.55294150 957.50 1.78934680e+00 -1.78407397e+00 2.52679281e+00 -0.78392259 0.47488991 957.75 1.74575411e+00 -2.24027314e+00 2.84015513e+00 -0.90883060 0.37049671 958.00 2.42735505e+00 -2.38296455e+00 3.40155444e+00 -0.77617024 0.40015799 958.25 3.51943573e+00 -2.71680420e+00 4.44606038e+00 -0.65739744 0.53730363 958.50 2.91099239e+00 -2.72385664e+00 3.98663664e+00 -0.75219994 0.41486859 958.75 1.63219642e+00 -4.39714992e+00 4.69030837e+00 -1.21536644 0.39137885 959.00 5.18634227e-01 -5.33544773e+00 5.36059549e+00 -1.47389538 0.44528581 959.25 -2.07778014e-02 -5.40233583e+00 5.40237578e+00 -1.57464239 0.42877091 959.50 -6.02264658e-01 -5.93345665e+00 5.96394421e+00 -1.67195304 0.42202479 959.75 1.23919799e+00 -5.49945588e+00 5.63734216e+00 -1.34916684 0.25917200 960.00 9.41971401e-01 -5.08280556e+00 5.16935416e+00 -1.38755025 0.19485037 960.25 3.54205679e-01 -3.50862320e+00 3.52645693e+00 -1.47018430 0.10423242 960.50 -4.40071499e-01 -2.50161997e+00 2.54003256e+00 -1.74492929 0.05308118 960.75 2.79861075e-01 -1.86159183e+00 1.88251066e+00 -1.42157947 0.03798785 961.00 1.19869811e-01 -2.34009253e+00 2.34316065e+00 -1.51961667 0.05604119 961.25 2.58375259e-01 -3.33590327e+00 3.34589426e+00 -1.49349779 0.14163243 961.50 -2.79462246e-01 -3.05355350e+00 3.06631508e+00 -1.66206242 0.11617101 961.75 4.02987090e-01 -1.65230267e+00 1.70073593e+00 -1.33157247 0.03683469 962.00 3.67359360e-01 -5.79550427e-01 6.86171697e-01 -1.00584433 0.00637651 962.25 1.67759221e-01 -1.09346436e+00 1.10625831e+00 -1.41856340 0.01756622 962.50 1.30557311e-01 -1.41387137e+00 1.41988642e+00 -1.47871714 0.02466446 962.75 9.99067368e-01 -1.80811840e+00 2.06577534e+00 -1.06600103 0.05824338 963.00 1.22274123e+00 -1.55127344e+00 1.97523300e+00 -0.90328110 0.05413317 963.25 1.22287496e+00 2.58577389e-01 1.24991417e+00 0.20838092 0.02820039 963.50 1.00204610e+00 4.75054278e-02 1.00317154e+00 0.04737296 0.01960358 963.75 2.23145142e+00 3.33134356e-02 2.23170008e+00 0.01492793 0.07814860 964.00 2.58463545e+00 7.12094084e-01 2.68093610e+00 0.26884071 0.11434770 964.25 3.21448001e+00 7.80688869e-01 3.30792334e+00 0.23825341 0.16951628 964.50 3.15681150e+00 4.00170163e-01 3.18207401e+00 0.12609151 0.16360553 964.75 2.90534497e+00 1.62116199e+00 3.32704006e+00 0.50895911 0.21133205 965.00 2.46019106e+00 1.54971939e+00 2.90760558e+00 0.56212826 0.21581469 965.25 2.53161812e+00 1.76508290e+00 3.08619636e+00 0.60885460 0.26740724 965.50 2.39623742e+00 1.60507496e+00 2.88413235e+00 0.59019034 0.23802545 965.75 1.17788541e+00 9.77395779e-01 1.53059353e+00 0.69264260 0.08771241 966.00 1.19931841e+00 5.99241923e-01 1.34069218e+00 0.46336923 0.06640907 966.25 9.71756369e-02 1.37043940e+00 1.37388036e+00 1.50000643 0.07582173 966.50 -2.50325048e-01 1.20629798e+00 1.23199734e+00 1.77540739 0.07753929 966.75 -2.19686447e-01 9.57044263e-01 9.81934751e-01 1.79643424 0.06144828 967.00 -9.02799439e-01 1.40361002e+00 1.66888223e+00 2.14237510 0.16657534 967.25 -1.01924274e+00 1.56519289e+00 1.86780206e+00 2.14800979 0.22534522 967.50 -1.51826839e+00 1.20265439e+00 1.93688319e+00 2.47167362 0.30212773 967.75 -2.04235640e+00 6.89170426e-01 2.15549891e+00 2.81615168 0.47476769 968.00 -2.00078968e+00 4.00017930e-01 2.04038567e+00 2.94426438 0.54345680 968.25 -2.05551399e+00 3.43037987e-01 2.08394166e+00 2.97622988 0.65669652 968.50 -2.00071333e+00 1.13716167e-01 2.00394241e+00 3.08481593 0.65360980 968.75 -2.05369725e+00 2.09172577e-02 2.05380377e+00 3.13140783 0.76704516 969.00 -2.21052432e+00 -3.16660344e-01 2.23309014e+00 -2.99930941 0.77935066 969.25 -2.31945379e+00 -5.02111131e-01 2.37317961e+00 -2.92840406 0.84225617 969.50 -2.25656740e+00 -6.40780421e-01 2.34578259e+00 -2.86491336 0.83841651 969.75 -2.23039117e+00 -5.70550830e-01 2.30221047e+00 -2.89115560 0.86935723 970.00 -2.09308941e+00 -7.81587599e-01 2.23425657e+00 -2.78421371 0.88064566 970.25 -2.22466950e+00 -9.70501684e-01 2.42714398e+00 -2.73023580 0.92930369 970.50 -2.45099007e+00 -1.26969995e+00 2.76034242e+00 -2.66362094 0.90434353 970.75 -2.50761080e+00 -1.50338441e+00 2.92374360e+00 -2.60151984 0.89578475 971.00 -2.46705450e+00 -1.48529647e+00 2.87966378e+00 -2.59966529 0.88866154 971.25 -2.49762148e+00 -1.53116861e+00 2.92960584e+00 -2.59163227 0.87385327 971.50 -2.77046105e+00 -1.47458511e+00 3.13844798e+00 -2.65247710 0.85925233 971.75 -2.84795710e+00 -1.45835569e+00 3.19963450e+00 -2.66833510 0.85960203 972.00 -2.69792965e+00 -1.29815978e+00 2.99400120e+00 -2.69312311 0.84099223 972.25 -2.79693877e+00 -1.17871495e+00 3.03516645e+00 -2.74274939 0.85719847 972.50 -2.75045025e+00 -1.27330124e+00 3.03088644e+00 -2.70802774 0.84418675 972.75 -2.76008774e+00 -1.25137515e+00 3.03051549e+00 -2.71592950 0.78451289 973.00 -2.82555646e+00 -1.25437473e+00 3.09147623e+00 -2.72379047 0.83740022 973.25 -2.73077966e+00 -1.44140590e+00 3.08784853e+00 -2.65592443 0.82989522 973.50 -2.80907864e+00 -2.03953260e+00 3.47139973e+00 -2.51359632 0.83583506 973.75 -2.71486600e+00 -2.02004535e+00 3.38394454e+00 -2.50189874 0.85511962 974.00 -2.70258786e+00 -2.15074324e+00 3.45393654e+00 -2.46941254 0.81466220 974.25 -2.91600122e+00 -2.13513853e+00 3.61412226e+00 -2.50957174 0.75058683 974.50 -3.60713146e+00 -2.10452053e+00 4.17617098e+00 -2.61344364 0.79608135 974.75 -3.78287337e+00 -1.87100181e+00 4.22028183e+00 -2.68227593 0.78687455 975.00 -4.17574739e+00 -1.46337503e+00 4.42474098e+00 -2.80452034 0.74338552 975.25 -4.45513425e+00 -1.54351970e+00 4.71494159e+00 -2.80807621 0.74214670 975.50 -5.21935716e+00 -1.58313989e+00 5.45417464e+00 -2.84709199 0.80007517 975.75 -5.81012510e+00 -1.53028959e+00 6.00827262e+00 -2.88405820 0.82161122 976.00 -6.40311089e+00 -1.67993588e+00 6.61981976e+00 -2.88501301 0.82615303 976.25 -6.58753622e+00 -1.56235321e+00 6.77027185e+00 -2.90872709 0.77998822 976.50 -6.85814181e+00 4.46072189e-01 6.87263337e+00 3.07664142 0.74155453 976.75 -7.32182551e+00 1.35551462e+00 7.44624393e+00 2.95853188 0.78019281 977.00 -7.59512968e+00 2.28716781e+00 7.93203198e+00 2.84909388 0.82139467 977.25 -7.14991566e+00 2.90647146e+00 7.71808722e+00 2.75549173 0.82436132 977.50 -5.96587161e+00 3.56418590e+00 6.94946366e+00 2.60306559 0.78091151 977.75 -5.96560779e+00 3.30950724e+00 6.82211950e+00 2.63509886 0.79496389 978.00 -6.34600218e+00 3.32157937e+00 7.16272527e+00 2.65939064 0.83716767 978.25 -5.69312889e+00 3.97236167e+00 6.94200071e+00 2.53238060 0.81592882 978.50 -5.33971292e+00 4.48289683e+00 6.97200818e+00 2.44320322 0.77526071 978.75 -5.10398109e+00 5.19253197e+00 7.28100345e+00 2.34759462 0.67940412 979.00 -4.21818659e+00 6.42567535e+00 7.68650778e+00 2.15169812 0.73680013 979.25 -3.47443795e+00 5.10223599e+00 6.17288677e+00 2.16863174 0.61053698 979.50 -2.80431386e+00 5.19199670e+00 5.90093264e+00 2.06602437 0.58957849 979.75 -1.76303539e+00 6.02255787e+00 6.27530852e+00 1.85557808 0.53662107 980.00 -1.21639053e+00 6.52759511e+00 6.63996264e+00 1.75502913 0.52616887 980.25 -7.44529149e-01 6.09111936e+00 6.13645327e+00 1.69242489 0.56506257 980.50 2.96794376e-01 5.92710470e+00 5.93453090e+00 1.52076403 0.55862789 980.75 2.50617651e+00 4.42890065e+00 5.08881928e+00 1.05585149 0.46146687 981.00 2.60256666e+00 4.25599179e+00 4.98866910e+00 1.02195909 0.53232969 981.25 2.25946228e+00 3.52654914e+00 4.18828350e+00 1.00098625 0.51519243 981.50 2.38144587e+00 2.82818855e+00 3.69728750e+00 0.87094206 0.44614301 981.75 2.83069159e+00 2.08965059e+00 3.51844489e+00 0.63591403 0.43639912 982.00 2.57986319e+00 2.14142921e+00 3.35282167e+00 0.69280060 0.44431648 982.25 2.14642735e+00 1.81923831e+00 2.81367702e+00 0.70307916 0.47264395 982.50 1.91771880e+00 1.36440695e+00 2.35356150e+00 0.61838516 0.42223695 982.75 1.28356692e+00 1.13685818e+00 1.71464006e+00 0.72485943 0.32465282 983.00 8.82475160e-01 1.15723675e+00 1.45532103e+00 0.91929822 0.28592270 983.25 7.65423976e-01 1.15685713e+00 1.38715258e+00 0.98628119 0.25196088 983.50 8.66250341e-01 1.23746066e+00 1.51052923e+00 0.96005524 0.30404401 983.75 9.39181675e-01 1.54682531e+00 1.80962172e+00 1.02512345 0.31180995 984.00 1.13319569e+00 1.69551227e+00 2.03933674e+00 0.98162922 0.37124055 984.25 1.18356639e+00 1.44085497e+00 1.86464271e+00 0.88312219 0.39897688 984.50 9.39301889e-01 1.34570031e+00 1.64109639e+00 0.96141237 0.31543000 984.75 8.24379580e-01 1.48599303e+00 1.69934605e+00 1.06430076 0.36818170 985.00 9.97108260e-01 1.43895132e+00 1.75065868e+00 0.96482373 0.36142510 985.25 1.13245716e+00 2.08162698e+00 2.36973207e+00 1.07255200 0.46487809 985.50 1.48573511e+00 1.79687747e+00 2.33156117e+00 0.87990080 0.54079376 985.75 1.71012969e+00 1.28704779e+00 2.14033539e+00 0.64516460 0.51806157 986.00 1.66047610e+00 1.18972426e+00 2.04270035e+00 0.62171143 0.42939748 986.25 1.56258327e+00 1.18334330e+00 1.96009384e+00 0.64815635 0.34466256 986.50 1.71857144e+00 1.33997779e+00 2.17922653e+00 0.66224251 0.43253288 986.75 1.70007969e+00 6.97054694e-01 1.83743196e+00 0.38910832 0.32095934 987.00 1.75152846e+00 1.67645698e-01 1.75953319e+00 0.09542326 0.33967844 987.25 1.92874483e+00 1.31503660e-01 1.93322265e+00 0.06807560 0.44122609 987.50 1.10767727e+00 1.25609737e-01 1.11477655e+00 0.11291685 0.18466605 987.75 6.05933012e-01 6.32923892e-01 8.76211999e-01 0.80718164 0.14698162 988.00 7.71527984e-01 8.25595759e-01 1.12998398e+00 0.81923846 0.15668532 988.25 3.19417728e-01 1.24637780e+00 1.28665664e+00 1.31991886 0.11883495 988.50 -1.30835023e-01 1.24538516e+00 1.25223880e+00 1.67546825 0.12152768 988.75 -1.81378612e-01 6.02195667e-01 6.28917977e-01 1.86334953 0.03803460 989.00 -1.15762335e-01 7.37738334e-01 7.46765537e-01 1.72644232 0.05618224 989.25 -4.13042478e-02 1.13017895e+00 1.13093347e+00 1.60732671 0.14639438 989.50 -4.97630432e-01 1.30616728e+00 1.39775141e+00 1.93480396 0.22236665 989.75 -3.17915764e-01 1.14063404e+00 1.18410998e+00 1.84261626 0.21002173 990.00 -3.13981668e-01 1.34248055e+00 1.37870900e+00 1.80054827 0.30920341 990.25 -4.91568468e-01 1.09507390e+00 1.20034428e+00 1.99272736 0.22180591 990.50 -5.51926048e-01 1.03361296e+00 1.17174149e+00 2.06125502 0.26280286 990.75 -8.64261035e-02 1.01767688e+00 1.02134015e+00 1.65551794 0.25462103 991.00 9.85941489e-02 8.53610858e-01 8.59285926e-01 1.45580343 0.25484341 991.25 -4.88347404e-02 8.28275587e-01 8.29713975e-01 1.62968768 0.23555934 991.50 -7.95376965e-02 8.40738521e-01 8.44492454e-01 1.66512015 0.21639348 991.75 5.39452011e-02 8.77094423e-01 8.78751791e-01 1.50936926 0.25521299 992.00 1.91313859e-01 5.78989119e-01 6.09778150e-01 1.25166340 0.20872789 992.25 1.59547058e-01 4.71767562e-01 4.98015960e-01 1.24468119 0.21069426 992.50 4.24395326e-01 3.82713116e-01 5.71472416e-01 0.73380013 0.25443580 992.75 5.23392823e-01 3.90274226e-01 6.52881321e-01 0.64071911 0.31100288 993.00 4.18864643e-01 4.73519653e-01 6.32193366e-01 0.84656780 0.41716555 993.25 3.51705074e-01 4.37597227e-01 5.61415882e-01 0.89379200 0.36626881 993.50 1.40796857e-01 1.23809231e-01 1.87489948e-01 0.72128647 0.03169423 993.75 1.63632232e-01 6.30260239e-02 1.75350469e-01 0.36765581 0.03095670 994.00 -8.13970887e-02 1.20647718e-01 1.45538166e-01 2.16431750 0.02054122 994.25 -1.54549862e-01 1.74431931e-01 2.33049690e-01 2.29583274 0.04689133 994.50 -1.06193426e-01 4.99585157e-02 1.17357986e-01 2.70186465 0.01301746 994.75 -2.71012373e-01 1.91975628e-02 2.71691466e-01 3.07087430 0.08766519 995.00 -2.17402188e-01 1.45731157e-01 2.61727494e-01 2.55105835 0.10591141 995.25 -2.74181540e-01 1.55487754e-01 3.15201457e-01 2.62571735 0.12464073 995.50 -3.09757034e-01 1.19409950e-01 3.31976138e-01 2.77365233 0.13744897 995.75 -2.91807602e-01 8.22519212e-02 3.03178257e-01 2.86685039 0.12507158 996.00 -4.35312297e-01 7.33183858e-02 4.41443520e-01 2.97473162 0.19778647 996.25 -5.76386783e-01 -1.13034052e-02 5.76497607e-01 -3.12198437 0.24497106 996.50 -6.92960214e-01 -6.06542127e-02 6.95609654e-01 -3.05428602 0.30041461 996.75 -6.91729862e-01 9.70597792e-02 6.98506122e-01 3.00218820 0.30081541 997.00 -7.62130655e-01 4.65525751e-02 7.63551097e-01 3.08058631 0.32144217 997.25 -8.45531190e-01 3.81078581e-02 8.46389510e-01 3.09655341 0.28282837 997.50 -7.94526001e-01 -1.39930392e-01 8.06754040e-01 -2.96726234 0.24904386 997.75 -6.41587506e-01 -3.49481435e-01 7.30596880e-01 -2.64281716 0.16339047 998.00 -1.28435180e+00 -7.44008461e-01 1.48428708e+00 -2.61654246 0.51029925 998.25 -1.39372874e+00 -8.43827827e-01 1.62927137e+00 -2.59717818 0.59809151 998.50 -1.59623845e+00 -9.40352845e-01 1.85263074e+00 -2.60922233 0.58757790 998.75 -2.11789753e+00 -1.07019791e+00 2.37293353e+00 -2.67370490 0.68870381 999.00 -2.65129154e+00 -9.34953640e-01 2.81131378e+00 -2.80256715 0.80210490 999.25 -2.96966837e+00 -6.45937868e-01 3.03910611e+00 -2.92741693 0.75069577 999.50 -3.43424353e+00 -8.43389852e-01 3.53628832e+00 -2.90077601 0.63140574 999.75 -3.11228526e+00 -5.72860174e-01 3.16456764e+00 -2.95956591 0.53092254 1000.00 -3.04055870e+00 0.00000000e+00 3.04055870e+00 3.14159265 0.60918311