========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0053 Injection acquisition : SIG0054 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 1.81274893e-02 0.00000000e+00 1.81274893e-02 0.00000000 0.32557202 0.25 1.65841240e-02 9.19919036e-04 1.66096183e-02 0.05541307 0.28531105 0.50 -4.22896618e-03 3.54951615e-03 5.52116110e-03 2.44332329 0.02500528 0.75 -4.58161337e-03 9.74069757e-04 4.68401462e-03 2.93210767 0.01627561 1.00 -3.28719613e-03 -1.47276219e-03 3.60203926e-03 -2.72037826 0.01053191 1.25 -8.63989672e-04 -7.81353154e-04 1.16489953e-03 -2.40637682 0.00161177 1.50 1.14068953e-04 4.85073030e-03 4.85207132e-03 1.54728483 0.02598422 1.75 -6.86137546e-04 1.81554239e-03 1.94087065e-03 1.93212828 0.00486639 2.00 -1.74720033e-03 -1.17184845e-03 2.10379129e-03 -2.55080247 0.00527454 2.25 -1.45612510e-03 -2.20877859e-03 2.64556292e-03 -2.15364288 0.00651486 2.50 1.12668223e-04 -1.89779128e-03 1.90113279e-03 -1.51149785 0.00225616 2.75 -2.06242843e-03 -2.03311949e-03 2.89606386e-03 -2.36335066 0.00642958 3.00 -3.78308397e-03 -4.97399498e-03 6.24918798e-03 -2.22102959 0.02667381 3.25 -1.95159669e-04 8.87262789e-05 2.14382016e-04 2.71489153 0.00002686 3.50 8.49268617e-04 2.19979907e-03 2.35804434e-03 1.20235904 0.00254443 3.75 -5.82061108e-03 3.63287077e-04 5.83193714e-03 3.07925960 0.01845020 4.00 -7.41819829e-03 -2.30122846e-03 7.76693751e-03 -2.84079182 0.03100040 4.25 2.33842329e-03 -1.28013762e-03 2.66589119e-03 -0.50087273 0.00302100 4.50 1.99949678e-03 1.28207966e-03 2.37522959e-03 0.57016486 0.00240269 4.75 -4.49126336e-03 -4.84999224e-03 6.61013399e-03 -2.31781071 0.01503700 5.00 -3.15081545e-03 -6.86247613e-03 7.55123941e-03 -2.00122240 0.01713593 5.25 -4.23105969e-03 -1.18897531e-03 4.39494350e-03 -2.86764648 0.00576753 5.50 -6.11778372e-03 -1.77647056e-03 6.37048863e-03 -2.85898648 0.01133564 5.75 -3.29736104e-03 -2.45660436e-03 4.11187242e-03 -2.50128551 0.00481329 6.00 4.80190211e-04 -2.55866570e-03 2.60333494e-03 -1.38528211 0.00156142 6.25 -8.13477943e-04 6.98519818e-03 7.03240641e-03 1.68673148 0.00982772 6.50 -4.48144827e-03 4.08812144e-03 6.06598018e-03 2.40206038 0.00809126 6.75 4.09416469e-03 -7.15827981e-03 8.24640251e-03 -1.05125864 0.01402797 7.00 6.26350780e-03 -4.40996974e-03 7.66024563e-03 -0.61345462 0.01084493 7.25 -6.29095772e-03 5.14875819e-03 8.12932101e-03 2.45570977 0.00983377 7.50 -9.52035169e-03 1.05109313e-03 9.57819884e-03 3.03163312 0.01486028 7.75 -4.06375420e-03 -1.30987941e-02 1.37146821e-02 -1.87161985 0.02709680 8.00 -1.10840825e-03 -4.26472951e-03 4.40641427e-03 -1.82507182 0.00310193 8.25 -2.28842747e-03 1.59160175e-03 2.78748927e-03 2.53389308 0.00116524 8.50 -5.31035332e-03 -5.23315983e-03 7.45558946e-03 -2.36351578 0.00801931 8.75 5.70073413e-03 -5.28686176e-03 7.77491331e-03 -0.74774873 0.00712654 9.00 1.92279994e-03 -1.13804810e-03 2.23434847e-03 -0.53442030 0.00065865 9.25 -1.49281678e-03 -7.84831956e-03 7.98903135e-03 -1.75875946 0.00763135 9.50 -1.25141334e-03 -8.25273167e-03 8.34707227e-03 -1.72128614 0.00819696 9.75 3.92143935e-03 -8.01875661e-03 8.92626149e-03 -1.11596047 0.00675551 10.00 -1.32002254e-03 2.57341412e-03 2.89221710e-03 2.04474703 0.00082445 10.25 -1.06092141e-02 6.29630105e-04 1.06278811e-02 3.08231470 0.01111576 10.50 3.37269730e-04 -8.43468312e-04 9.08399507e-04 -1.19041014 0.00008673 10.75 5.06446614e-03 9.03985261e-03 1.03618412e-02 1.06012708 0.00816815 11.00 -6.52820335e-04 1.38998339e-03 1.53565237e-03 2.00987913 0.00019096 11.25 3.00590166e-05 -1.06555767e-02 1.06556191e-02 -1.56797537 0.00827288 11.50 7.15712381e-03 -6.92826763e-03 9.96119037e-03 -0.76915182 0.00765581 11.75 3.39473346e-04 -1.06475671e-03 1.11756387e-03 -1.26215765 0.00009203 12.00 -6.18270465e-03 -9.98754592e-03 1.17463573e-02 -2.12509934 0.01165068 12.25 -1.18392656e-02 -2.09811820e-02 2.40910401e-02 -2.08453708 0.03985315 12.50 -2.93735997e-03 -5.22307020e-03 5.99237398e-03 -2.08309604 0.00245919 12.75 -6.65987337e-03 5.30991240e-03 8.51757495e-03 2.46850065 0.00454300 13.00 -2.34326904e-03 -7.29159644e-03 7.65886991e-03 -1.88173763 0.00401166 13.25 1.15652930e-02 -8.45601945e-03 1.43269071e-02 -0.63133068 0.01167621 13.50 4.74513915e-03 7.24905388e-03 8.66401337e-03 0.99120300 0.00357084 13.75 9.72760348e-04 6.88901697e-03 6.95735708e-03 1.43051921 0.00215961 14.00 5.94248859e-03 -1.84691593e-03 6.22288270e-03 -0.30133390 0.00129576 14.25 1.04200148e-02 2.25749574e-03 1.06617539e-02 0.21335268 0.00293249 14.50 -5.92532778e-03 1.03831290e-02 1.19548683e-02 2.08936951 0.00563078 14.75 -9.54958695e-03 -5.25614925e-03 1.09005374e-02 -2.63843784 0.00488349 15.00 -1.20639430e-03 6.96875057e-03 7.07240212e-03 1.74221229 0.00217235 15.25 -2.81236828e-03 7.05863699e-03 7.59827425e-03 1.94994798 0.00233594 15.50 -2.94875673e-03 6.67527215e-03 7.29756292e-03 1.98676280 0.00190569 15.75 -3.54804266e-03 -9.47796455e-04 3.67245488e-03 -2.88055568 0.00053497 16.00 1.83938464e-02 -1.81688101e-03 1.84833612e-02 -0.09845719 0.01515742 16.25 1.84052808e-02 7.80746474e-03 1.99927704e-02 0.40119029 0.01613231 16.50 -4.56472180e-03 7.10804959e-03 8.44754722e-03 2.14166195 0.00241253 16.75 -7.95287066e-03 -4.06562010e-03 8.93182056e-03 -2.66901402 0.00279692 17.00 -6.90542238e-03 -7.00838970e-03 9.83882028e-03 -2.34879426 0.00292514 17.25 -9.42689197e-03 -4.14635179e-03 1.02984720e-02 -2.72721738 0.00306441 17.50 -8.21261173e-03 -8.75196889e-03 1.20018311e-02 -2.32441206 0.00349966 17.75 1.17818118e-03 -5.09861157e-03 5.23296768e-03 -1.34370356 0.00071738 18.00 8.38805846e-03 1.13832964e-02 1.41399775e-02 0.93574873 0.00548968 18.25 2.57438897e-03 1.14220893e-02 1.17086123e-02 1.34911368 0.00421108 18.50 1.58680281e-03 -1.08770139e-02 1.09921506e-02 -1.42593237 0.00382133 18.75 9.99988612e-03 -7.98514957e-03 1.27968877e-02 -0.67384032 0.00443391 19.00 -2.28229693e-03 6.97283552e-03 7.33684636e-03 1.88711847 0.00105265 19.25 -9.24942501e-03 7.92557772e-04 9.28331896e-03 3.05611420 0.00187228 19.50 4.62984697e-03 -8.21374450e-03 9.42873701e-03 -1.05751801 0.00153218 19.75 4.72583678e-03 9.32652733e-03 1.04555079e-02 1.10179581 0.00213929 20.00 -2.09747583e-02 4.65697761e-02 5.10752830e-02 1.99397804 0.05268119 20.25 -2.55925055e-03 8.04562583e-03 8.44285842e-03 1.87876770 0.00178245 20.50 1.24531999e-02 2.51738382e-03 1.27050939e-02 0.19945965 0.00352356 20.75 9.17842435e-03 1.59297562e-02 1.83847928e-02 1.04807488 0.00681659 21.00 1.21175294e-03 2.73349686e-02 2.73618138e-02 1.52649556 0.00900160 21.25 1.29867060e-02 -8.71962354e-03 1.56424540e-02 -0.59129090 0.00437395 21.50 2.07312484e-02 2.98641246e-04 2.07333993e-02 0.01440437 0.00788523 21.75 4.03392480e-03 8.65124640e-03 9.54550227e-03 1.13448468 0.00149925 22.00 7.82187930e-03 5.07033084e-03 9.32148329e-03 0.57512579 0.00128208 22.25 1.90518337e-02 2.77717109e-02 3.36784841e-02 0.96951749 0.01655720 22.50 1.27008302e-02 5.79011601e-02 5.92777819e-02 1.35486263 0.03589753 22.75 3.26856679e-03 1.32026107e-02 1.36011933e-02 1.32810628 0.00229375 23.00 -9.38635925e-03 1.95846650e-02 2.17178002e-02 2.01772353 0.00557075 23.25 2.94374909e-02 -1.77697839e-02 3.43850416e-02 -0.54309508 0.01321027 23.50 7.54205667e-02 -2.07056477e-02 7.82111611e-02 -0.26793462 0.05178399 23.75 6.31049633e-02 -2.31962839e-02 6.72332059e-02 -0.35225190 0.03099709 24.00 1.00331916e-01 5.23317738e-03 1.00468301e-01 0.05211143 0.05034468 24.25 6.36625391e-02 -3.58974908e-02 7.30858996e-02 -0.51343069 0.03452465 24.50 4.96093969e-02 -6.17532945e-03 4.99922690e-02 -0.12384200 0.01585085 24.75 4.73494936e-02 5.63661472e-03 4.76838125e-02 0.11848517 0.01600354 25.00 4.86712945e-02 9.97335288e-03 4.96826195e-02 0.20211455 0.01707920 25.25 2.92244105e-02 2.77103908e-02 4.02732160e-02 0.75881226 0.01580046 25.50 2.58045338e-02 4.18435449e-02 4.91605148e-02 1.01819441 0.02455191 25.75 1.44751036e-02 2.50734085e-02 2.89517606e-02 1.04722853 0.00657479 26.00 2.91304026e-02 8.20246437e-03 3.02631918e-02 0.27447087 0.00637266 26.25 4.52422167e-02 -5.60788423e-03 4.55884474e-02 -0.12332344 0.02190356 26.50 2.73884670e-02 -9.11896966e-03 2.88666544e-02 -0.32140484 0.01065249 26.75 -7.44227908e-04 -6.06715742e-03 6.11263236e-03 -1.69285159 0.00040892 27.00 -7.23826022e-03 7.73954904e-03 1.05968406e-02 2.32273821 0.00128603 27.25 -9.15435108e-03 2.51373531e-02 2.67523581e-02 1.92004142 0.00842143 27.50 -1.26419930e-03 2.79242352e-03 3.06526165e-03 1.99591386 0.00009707 27.75 5.93687743e-02 -3.98417293e-02 7.14983550e-02 -0.59105795 0.03934128 28.00 5.06146422e-02 -1.58880911e-02 5.30497261e-02 -0.30416259 0.02569242 28.25 4.01524424e-03 -1.80178061e-02 1.84597812e-02 -1.35153049 0.00296023 28.50 -5.35782379e-03 -1.71422452e-02 1.79600347e-02 -1.87372755 0.00289587 28.75 2.83702223e-02 2.99788257e-02 4.12746836e-02 0.81295981 0.01560795 29.00 1.06991934e-02 4.74507192e-03 1.17042064e-02 0.41743380 0.00133411 29.25 -2.91446058e-02 -4.88577404e-03 2.95512916e-02 -2.97549802 0.00728652 29.50 5.35768959e-03 -9.28476788e-04 5.43754604e-03 -0.17159375 0.00026676 29.75 3.96436376e-03 4.91239593e-02 4.92836642e-02 1.49026961 0.01818492 30.00 1.17072732e-02 2.03568956e-02 2.34832588e-02 1.04888606 0.00509107 30.25 5.60433309e-02 -9.33943125e-03 5.68161941e-02 -0.16512917 0.03060176 30.50 4.23547332e-02 -1.39108024e-03 4.23775711e-02 -0.03283176 0.01776105 30.75 1.76952313e-02 -5.16640450e-03 1.84340160e-02 -0.28406988 0.00297227 31.00 4.15657373e-03 -7.90206421e-03 8.92859025e-03 -1.08655700 0.00079988 31.25 3.82617308e-02 -3.47562990e-02 5.16910085e-02 -0.73742724 0.01871803 31.50 1.59708520e-02 1.54789803e-02 2.22411094e-02 0.76975956 0.00396004 31.75 -1.11510162e-02 5.21520397e-02 5.33308579e-02 1.78144191 0.02046340 32.00 1.61400730e-03 2.65993000e-02 2.66482228e-02 1.51019207 0.00644965 32.25 2.71614223e-02 2.13320920e-02 3.45369514e-02 0.66576375 0.01013591 32.50 4.98804635e-03 1.58860008e-02 1.66506945e-02 1.26655454 0.00224187 32.75 -3.18189360e-02 4.07315502e-03 3.20785798e-02 3.01427467 0.00797060 33.00 2.07520069e-02 -2.03452312e-02 2.90615592e-02 -0.77550060 0.00759448 33.25 4.90715226e-02 1.73479718e-03 4.91021777e-02 0.03533771 0.01908600 33.50 2.51212996e-02 1.27011624e-02 2.81495864e-02 0.46811228 0.00554929 33.75 2.07016391e-02 1.47378500e-02 2.54118492e-02 0.61867929 0.00413545 34.00 2.93902389e-02 -3.48127339e-02 4.55599888e-02 -0.86965682 0.01149475 34.25 5.31062971e-02 -9.58621829e-03 5.39645659e-02 -0.17858690 0.01208145 34.50 2.07167660e-02 2.30264824e-02 3.09742358e-02 0.83815084 0.00661047 34.75 5.56537378e-02 5.02438331e-04 5.56560057e-02 0.00902769 0.02165246 35.00 1.29896905e-02 2.59596963e-02 2.90282258e-02 1.10684545 0.00573078 35.25 -1.11191460e-02 2.81948017e-02 3.03081218e-02 1.94643869 0.00600701 35.50 2.60855255e-02 1.67818508e-02 3.10174976e-02 0.57167876 0.00642752 35.75 2.95248606e-02 2.50897818e-02 3.87455100e-02 0.70436920 0.00908381 36.00 5.79015169e-02 -2.22072222e-02 6.20140821e-02 -0.36623179 0.01852852 36.25 1.23318342e-01 -1.77863924e-02 1.24594419e-01 -0.14324369 0.04805919 36.50 4.58379657e-02 -9.47129913e-02 1.05222002e-01 -1.12005716 0.02082599 36.75 8.89392965e-03 -3.51275183e-02 3.62359563e-02 -1.32281775 0.00378025 37.00 5.89822341e-02 3.30882940e-02 6.76294250e-02 0.51123973 0.01759010 37.25 3.15441515e-02 1.34365591e-02 3.42866536e-02 0.40268383 0.00519842 37.50 2.59649916e-02 -4.48101936e-03 2.63488201e-02 -0.17089591 0.00346384 37.75 4.76253171e-02 -6.81016176e-03 4.81097613e-02 -0.14203173 0.01224727 38.00 7.13587477e-02 4.27243209e-02 8.31711397e-02 0.53948204 0.03766299 38.25 4.15451910e-02 1.66936469e-02 4.47736613e-02 0.38207349 0.01071941 38.50 4.48409327e-02 -1.90597738e-02 4.87235489e-02 -0.40191555 0.00946115 38.75 3.92163425e-02 1.82604193e-02 4.32592699e-02 0.43577793 0.00850107 39.00 -1.52218379e-02 3.11632164e-02 3.46821338e-02 2.02516559 0.00541817 39.25 -1.25950567e-03 1.90712082e-03 2.28548996e-03 2.15446364 0.00002659 39.50 5.37617719e-02 2.53907515e-02 5.94560205e-02 0.44122888 0.01729668 39.75 4.09049773e-02 1.34175374e-02 4.30493610e-02 0.31695846 0.00984827 40.00 4.36097442e-04 -4.07150670e-02 4.07174024e-02 -1.56008578 0.00873777 40.25 2.65982141e-02 -3.29752285e-02 4.23654421e-02 -0.89203668 0.00927545 40.50 1.52527245e-02 -4.22730063e-04 1.52585814e-02 -0.02770796 0.00107105 40.75 2.45151007e-03 1.74809977e-02 1.76520588e-02 1.43146641 0.00160751 41.00 -3.81331852e-02 4.23765594e-02 5.70080047e-02 2.30353687 0.01561323 41.25 -4.69265035e-03 -1.98662471e-02 2.04129552e-02 -1.80275676 0.00193024 41.50 4.03134437e-02 8.51746838e-03 4.12034102e-02 0.20821886 0.00632396 41.75 2.58096518e-02 1.69832367e-02 3.08960913e-02 0.58199172 0.00372504 42.00 3.42844512e-02 2.87349996e-02 4.47339222e-02 0.69756538 0.00667811 42.25 7.87190656e-02 6.41593993e-02 1.01553532e-01 0.68384625 0.03387494 42.50 9.92535168e-02 1.18504183e-01 1.54578465e-01 0.87357300 0.06697059 42.75 3.99634681e-02 2.49641610e-02 4.71199333e-02 0.55836524 0.00818324 43.00 6.23451013e-02 7.01230429e-03 6.27382186e-02 0.11200489 0.01607288 43.25 3.14470230e-02 1.00204136e-02 3.30049079e-02 0.30847266 0.00460847 43.50 4.74478764e-02 1.85318996e-02 5.09385147e-02 0.37235406 0.01086048 43.75 9.51172442e-03 -8.55638218e-03 1.27939274e-02 -0.73257285 0.00062586 44.00 4.72036812e-02 -1.20590866e-02 4.87196991e-02 -0.25011948 0.00742702 44.25 4.72116113e-02 7.61847652e-02 8.96273099e-02 1.01601816 0.02145549 44.50 8.15895457e-02 1.41916606e-01 1.63698433e-01 1.04902826 0.05638395 44.75 1.72486417e-01 4.03306408e-02 1.77138716e-01 0.22969269 0.08235913 45.00 1.69448310e-01 8.57641077e-02 1.89916329e-01 0.46854537 0.09184254 45.25 4.19919249e-02 2.19795426e-02 4.73964350e-02 0.48221000 0.00677790 45.50 -2.50177514e-02 -1.46950125e-02 2.90143288e-02 -2.61050170 0.00239932 45.75 -1.39356669e-02 2.77290295e-02 3.10338829e-02 2.03649461 0.00329471 46.00 -2.51216579e-02 3.82416733e-02 4.57550355e-02 2.15201972 0.00659460 46.25 1.19766642e-02 7.74319583e-02 7.83527195e-02 1.41733898 0.01484345 46.50 -3.46500413e-03 9.43879326e-02 9.44515117e-02 1.60749009 0.02055813 46.75 8.30449778e-02 1.23423536e-01 1.48761008e-01 0.97852822 0.04677214 47.00 5.38433514e-02 1.11941267e-01 1.24217365e-01 1.12246681 0.03149950 47.25 8.06844106e-03 6.11938717e-02 6.17234937e-02 1.43970203 0.00717759 47.50 2.75951487e-02 6.28042536e-02 6.85993186e-02 1.15680613 0.00739355 47.75 1.99126013e-01 1.39448999e-01 2.43099142e-01 0.61093082 0.05185433 48.00 2.25338326e-01 2.65319707e-01 3.48097555e-01 0.86670376 0.08657198 48.25 2.16159555e-01 2.75462085e-01 3.50148988e-01 0.90544451 0.04780172 48.50 2.58296351e-01 1.65935762e-01 3.07004368e-01 0.57103090 0.03146392 48.75 2.63537139e-01 5.31032814e-03 2.63590636e-01 0.02014748 0.01751566 49.00 2.89454219e-01 -2.95773405e-02 2.90961447e-01 -0.10182971 0.02166020 49.25 1.02418362e+00 -3.83799878e-01 1.09373417e+00 -0.35854040 0.12839661 49.50 1.34245307e+00 2.18199537e-01 1.36007033e+00 0.16112885 0.14412825 49.75 1.75980136e+00 9.50773724e-01 2.00021787e+00 0.49534485 0.16346589 50.00 2.18627206e+00 6.30329823e-01 2.27532442e+00 0.28070024 0.08062525 50.25 1.13425265e+00 -3.41223251e+00 3.59581142e+00 -1.24987900 0.08399057 50.50 4.00344014e-01 -1.64048349e+00 1.68862708e+00 -1.33143465 0.04745745 50.75 -4.78077585e-01 -1.24954347e-01 4.94137396e-01 -2.88594332 0.02348327 51.00 -1.97760053e-01 -2.27653216e-01 3.01554349e-01 -2.28604128 0.02061992 51.25 5.54428300e-02 -1.93092057e-01 2.00894126e-01 -1.29118682 0.01745224 51.50 -7.59210907e-02 -9.16260110e-02 1.18993016e-01 -2.26273321 0.00964928 51.75 -1.59624901e-01 -1.07164413e-02 1.59984221e-01 -3.07455810 0.02098997 52.00 -1.46348730e-01 -1.41864107e-01 2.03821921e-01 -2.37175334 0.03902942 52.25 -1.73271483e-01 -1.96023217e-01 2.61625894e-01 -2.29466365 0.06410608 52.50 -1.89373166e-01 -1.12368089e-01 2.20201689e-01 -2.60606346 0.05055250 52.75 -2.41703763e-01 -6.46226192e-02 2.50193509e-01 -2.88034036 0.07101743 53.00 -1.61530093e-01 -3.73660511e-02 1.65795635e-01 -2.91426560 0.03241521 53.25 -1.18388590e-01 -4.25557403e-02 1.25804806e-01 -2.79651686 0.01613023 53.50 -1.07941211e-02 -1.83463480e-02 2.12861817e-02 -2.10260752 0.00063468 53.75 -2.68368272e-02 7.10159546e-03 2.77605467e-02 2.88290083 0.00115190 54.00 -4.86193700e-02 -5.82788541e-02 7.58964292e-02 -2.26607773 0.00777309 54.25 -1.04514679e-01 -6.56985018e-02 1.23448821e-01 -2.58040482 0.02070038 54.50 -1.52051255e-01 -8.75263802e-02 1.75443584e-01 -2.61927953 0.04859259 54.75 -2.19223249e-01 -8.87542069e-02 2.36508228e-01 -2.75690568 0.09646251 55.00 -6.25092553e-02 -8.71902454e-02 1.07282552e-01 -2.19279421 0.01560018 55.25 -4.73096781e-02 -9.18784635e-02 1.03343397e-01 -2.04630530 0.01255320 55.50 -4.52112596e-02 -6.45574492e-02 7.88144798e-02 -2.18174104 0.00912300 55.75 -4.86917220e-02 -2.33141075e-02 5.39854740e-02 -2.69503989 0.00379046 56.00 -7.09121930e-02 1.78203511e-02 7.31170570e-02 2.89538928 0.00608007 56.25 -9.76698034e-02 -4.24790913e-03 9.77621359e-02 -3.09812749 0.01105880 56.50 -6.53474488e-02 6.93974158e-03 6.57149076e-02 3.03579161 0.00493500 56.75 -6.90888210e-02 -5.15138762e-03 6.92806032e-02 -3.06716856 0.00460555 57.00 -9.71919746e-02 2.65362399e-01 2.82601279e-01 1.92188374 0.08480066 57.25 -1.23068596e-01 2.57021577e-01 2.84966612e-01 2.01736165 0.10137423 57.50 -1.39094430e-01 1.47051267e-01 2.02413773e-01 2.32839471 0.04785506 57.75 -1.49541785e-01 1.80587259e-01 2.34466423e-01 2.26242983 0.06113887 58.00 -1.51681994e-01 3.07205469e-01 3.42611482e-01 2.02942960 0.11360204 58.25 -1.63190019e-01 3.23063415e-01 3.61940537e-01 2.03854197 0.12197739 58.50 -2.34056611e-01 5.06683734e-01 5.58131618e-01 2.00353366 0.26184230 58.75 -1.80181469e-01 4.77125401e-01 5.10013735e-01 1.93187920 0.20520034 59.00 -9.12192870e-02 7.35151223e-01 7.40788957e-01 1.69424768 0.41335168 59.25 -4.49521366e-02 5.60808090e-01 5.62606798e-01 1.65078132 0.29497756 59.50 -1.56359637e-01 2.75097840e-01 3.16428756e-01 2.08763997 0.16931388 59.75 -2.42195577e-01 1.62070468e-01 2.91419858e-01 2.55185768 0.11259778 60.00 -4.08756824e-01 3.17671992e-01 5.17684881e-01 2.48093065 0.26274088 60.25 -4.11566420e-01 2.18986549e-01 4.66199557e-01 2.65261107 0.20316380 60.50 -4.82767594e-01 3.48288115e-01 5.95289141e-01 2.51662152 0.24293672 60.75 -3.30284406e-01 3.60714562e-01 4.89083616e-01 2.31218501 0.15761503 61.00 -2.79022628e-01 3.22902472e-01 4.26754770e-01 2.28342404 0.13126396 61.25 -3.10262180e-01 1.72109607e-01 3.54801828e-01 2.63513047 0.07512992 61.50 -4.72074142e-01 3.36243119e-01 5.79580392e-01 2.52268076 0.20176981 61.75 -4.20353535e-01 2.89852304e-01 5.10599111e-01 2.53791859 0.16639958 62.00 -5.20443361e-01 4.12757982e-01 6.64251793e-01 2.47107987 0.29647943 62.25 -4.45510164e-01 4.07301996e-01 6.03634179e-01 2.40096711 0.20293703 62.50 -4.55358205e-01 4.85869510e-01 6.65898097e-01 2.32378934 0.23316394 62.75 -3.89536691e-01 4.35748575e-01 5.84478960e-01 2.30025786 0.18935329 63.00 -4.27037000e-01 5.00683304e-01 6.58061068e-01 2.27697645 0.28461971 63.25 -5.13999738e-01 4.78900283e-01 7.02524883e-01 2.39153022 0.26381398 63.50 -8.16139341e-01 4.62899559e-01 9.38274707e-01 2.62565364 0.45177968 63.75 -9.51308273e-01 3.52582228e-01 1.01454505e+00 2.78665978 0.40065176 64.00 -1.07979456e+00 3.49441746e-01 1.13492988e+00 2.82861057 0.43074896 64.25 -1.04234397e+00 3.10759864e-01 1.08768224e+00 2.85184718 0.31417689 64.50 -1.15804098e+00 3.89995472e-01 1.22194738e+00 2.81675074 0.35419350 64.75 -8.93141670e-01 2.96534580e-01 9.41081717e-01 2.82103094 0.20674485 65.00 -7.73791949e-01 4.97676599e-01 9.20019552e-01 2.57003673 0.16591662 65.25 -8.29699951e-01 3.72273607e-01 9.09389712e-01 2.71983314 0.13983332 65.50 -1.16790955e+00 2.27319975e-01 1.18982649e+00 2.94935781 0.17767801 65.75 -1.30177846e+00 4.79432277e-01 1.38725718e+00 2.78871747 0.17913163 66.00 -1.40215762e+00 9.12210132e-01 1.67277414e+00 2.56481260 0.23388500 66.25 -1.34186494e+00 7.48174721e-01 1.53634857e+00 2.63296119 0.18722753 66.50 -1.60006200e+00 9.62428046e-01 1.86720811e+00 2.60007518 0.23743485 66.75 -1.65242602e+00 1.18128129e+00 2.03124033e+00 2.52095178 0.27474851 67.00 -2.11899001e+00 9.68202962e-01 2.32970720e+00 2.71300130 0.32546248 67.25 -2.77813828e+00 1.67482000e+00 3.24392885e+00 2.59907509 0.33827207 67.50 -3.36618111e+00 1.89970648e+00 3.86523738e+00 2.62779847 0.38634634 67.75 -4.56438883e+00 2.14256678e+00 5.04224531e+00 2.70271566 0.42695547 68.00 -6.95736059e+00 2.63429780e+00 7.43938111e+00 2.77963925 0.53976700 68.25 -1.33427192e+01 4.82078656e+00 1.41869002e+01 2.79488258 0.67914886 68.50 -1.64347132e+01 7.69195296e+00 1.81456864e+01 2.70384585 0.66492161 68.75 -7.34031935e+00 1.63207142e+01 1.78954184e+01 1.99344632 0.30832970 69.00 7.40773069e+00 6.67458432e+00 9.97118598e+00 0.73338363 0.10846583 69.25 9.10548877e+00 4.73320405e-03 9.10549000e+00 0.00051982 0.45902518 69.50 6.79013733e+00 9.70293707e-01 6.85911327e+00 0.14193661 0.58580793 69.75 4.84979351e+00 1.11817359e-01 4.85108237e+00 0.02305202 0.61348148 70.00 4.21061197e+00 -3.34821804e-02 4.21074509e+00 -0.00795169 0.67217988 70.25 3.57622070e+00 -1.76028259e-01 3.58055030e+00 -0.04918217 0.79127159 70.50 3.19531648e+00 -7.69738477e-02 3.19624348e+00 -0.02408493 0.81450960 70.75 2.88638873e+00 -8.54087574e-02 2.88765208e+00 -0.02958155 0.82637134 71.00 2.46427840e+00 1.00935055e-02 2.46429907e+00 0.00409590 0.70957941 71.25 1.80583597e+00 -4.07797405e-02 1.80629636e+00 -0.02257836 0.58841531 71.50 1.45899943e+00 -4.25096039e-03 1.45900562e+00 -0.00291361 0.43174613 71.75 1.43641657e+00 -8.75873728e-02 1.43908447e+00 -0.06090090 0.56596835 72.00 1.46127070e+00 -6.64147842e-04 1.46127085e+00 -0.00045450 0.61202419 72.25 1.44480407e+00 8.25813066e-02 1.44716221e+00 0.05709532 0.73697758 72.50 1.33853325e+00 7.06743327e-02 1.34039775e+00 0.05275085 0.71695756 72.75 1.29260975e+00 -1.75409546e-02 1.29272877e+00 -0.01356935 0.78126965 73.00 9.65070607e-01 1.32264527e-02 9.65161238e-01 0.01370431 0.62551994 73.25 8.87243869e-01 4.11762219e-02 8.88198831e-01 0.04637586 0.76344695 73.50 8.14914261e-01 2.28706168e-02 8.15235131e-01 0.02805769 0.77312138 73.75 7.07644950e-01 1.55072130e-02 7.07814841e-01 0.02191033 0.79526222 74.00 5.69899512e-01 8.58291641e-02 5.76326383e-01 0.14948064 0.65960212 74.25 5.06136499e-01 1.13441842e-01 5.18693751e-01 0.22048897 0.67935260 74.50 3.09898764e-01 1.27362693e-01 3.35049995e-01 0.38993729 0.29125169 74.75 1.79278661e-01 1.61781451e-01 2.41483076e-01 0.73414068 0.23738377 75.00 4.89820428e-03 2.83375524e-01 2.83417854e-01 1.55351284 0.17376845 75.25 -1.51756251e-01 4.67070231e-01 4.91105447e-01 1.88494772 0.34187824 75.50 -1.25894095e-01 5.36449332e-01 5.51023783e-01 1.80130531 0.25834852 75.75 -1.17114956e-01 5.13145186e-01 5.26340094e-01 1.79518268 0.24158623 76.00 -1.31416236e-01 4.26920649e-01 4.46689453e-01 1.86941516 0.11252011 76.25 -4.99178322e-02 5.56559286e-01 5.58793369e-01 1.66024704 0.11566120 76.50 1.37872485e-01 5.78190985e-01 5.94401915e-01 1.33671279 0.12223920 76.75 -2.27154405e-01 6.70561857e-01 7.07991757e-01 1.89741604 0.16691489 77.00 -6.36863912e-01 1.03445432e+00 1.21478039e+00 2.12264525 0.55512194 77.25 -8.39614601e-01 1.08838229e+00 1.37460128e+00 2.22787438 0.64003194 77.50 -1.33996618e+00 1.02763847e+00 1.68865337e+00 2.48735434 0.56372117 77.75 -1.81754466e+00 1.57919370e+00 2.40776272e+00 2.42625020 0.48090663 78.00 -2.39725080e+00 5.89297002e+00 6.36191065e+00 1.95714962 0.57784950 78.25 -3.80024196e-01 7.79978068e+00 7.80903304e+00 1.61948025 0.55398350 78.50 5.27108674e+00 5.99332503e+00 7.98149737e+00 0.84942734 0.55556014 78.75 5.30365166e+00 3.35819884e+00 6.27743740e+00 0.56446435 0.52388197 79.00 4.36179772e+00 2.27586958e-01 4.36773113e+00 0.05213006 0.51595677 79.25 3.45868051e+00 -5.33887130e-01 3.49964374e+00 -0.15315273 0.49548093 79.50 2.48703878e+00 -6.70480011e-01 2.57583100e+00 -0.26332936 0.54529854 79.75 2.06809223e+00 -7.05916721e-01 2.18525144e+00 -0.32893662 0.47301779 80.00 1.52111007e+00 -9.95464435e-01 1.81789034e+00 -0.57948517 0.45302143 80.25 1.16538623e+00 -8.11014946e-01 1.41981348e+00 -0.60798209 0.37250472 80.50 8.76915022e-01 -7.55571373e-01 1.15752670e+00 -0.71120403 0.37219416 80.75 8.32226115e-01 -6.34652692e-01 1.04660611e+00 -0.65151422 0.31511835 81.00 5.00998782e-01 -8.85962264e-01 1.01780593e+00 -1.05614187 0.28655517 81.25 2.29071870e-01 -6.50103943e-01 6.89281553e-01 -1.23201890 0.19178910 81.50 3.54864911e-02 -4.14631560e-01 4.16147355e-01 -1.48541878 0.10213357 81.75 1.24042442e-02 -1.55195936e-01 1.55690860e-01 -1.49103953 0.01355541 82.00 -5.79398072e-02 -6.82247924e-02 8.95077849e-02 -2.27485398 0.00513486 82.25 -1.08247262e-01 -4.05114322e-03 1.08323042e-01 -3.10418521 0.00753514 82.50 -2.84046769e-01 7.23664582e-02 2.93120233e-01 2.89213009 0.04448221 82.75 -1.30070176e-01 1.71131217e-01 2.14951493e-01 2.22070548 0.02775157 83.00 -2.25587007e-02 1.47993268e-01 1.49702714e-01 1.72206252 0.01985315 83.25 -2.33487804e-02 1.98219561e-01 1.99589979e-01 1.68804854 0.03553722 83.50 -6.07075669e-02 1.64204017e-01 1.75066753e-01 1.92491953 0.03015595 83.75 -5.44383898e-02 1.17604110e-01 1.29592689e-01 2.00432209 0.01570805 84.00 -5.84765302e-02 7.00427740e-02 9.12441493e-02 2.26644013 0.00895109 84.25 -5.08588387e-02 8.65617417e-02 1.00396995e-01 2.10200671 0.00953429 84.50 -1.07199643e-02 6.08791888e-02 6.18158011e-02 1.74509539 0.00428756 84.75 1.85562491e-02 5.30891071e-02 5.62386670e-02 1.23454005 0.00430567 85.00 1.15980935e-02 5.65431524e-02 5.77203938e-02 1.36848321 0.00574296 85.25 1.96884198e-02 8.73997113e-02 8.95898622e-02 1.34922614 0.01159750 85.50 4.60982347e-02 7.58594751e-02 8.87677149e-02 1.02474939 0.01300439 85.75 2.40610986e-02 6.29134347e-02 6.73575291e-02 1.20551220 0.00720665 86.00 1.55336980e-02 7.74485446e-02 7.89909668e-02 1.37285469 0.01128812 86.25 -1.64635945e-01 6.50854952e-02 1.77034223e-01 2.76511878 0.04990791 86.50 -2.04846672e-01 3.97240214e-02 2.08662782e-01 2.95004930 0.07141529 86.75 -7.20432989e-02 3.17068491e-02 7.87118873e-02 2.72699510 0.01187201 87.00 -5.69187749e-02 1.56941067e-02 5.90427974e-02 2.87254964 0.00767838 87.25 -4.95282362e-02 2.64112038e-02 5.61301868e-02 2.65169593 0.00478229 87.50 -1.58494118e-02 3.84474706e-02 4.15861979e-02 1.96180584 0.00200633 87.75 -3.43665808e-02 1.21974903e-01 1.26723869e-01 1.84542822 0.01247230 88.00 -1.25431863e-01 2.23185283e-01 2.56017232e-01 2.08281179 0.05073696 88.25 -1.89689799e-01 1.37683837e-01 2.34390825e-01 2.51373618 0.03493064 88.50 -1.46524342e-01 1.46955037e-01 2.07521483e-01 2.35472694 0.02882492 88.75 -2.89340607e-02 3.00754638e-01 3.02143231e-01 1.66670603 0.07442172 89.00 2.99449236e-02 2.98534720e-01 3.00032794e-01 1.47082438 0.06741315 89.25 2.46400882e-01 2.66548181e-01 3.62989432e-01 0.82465537 0.11804472 89.50 2.35233976e-01 2.63453487e-01 3.53189416e-01 0.84192545 0.12902720 89.75 1.61365917e-01 2.30298252e-01 2.81204985e-01 0.95961257 0.12210496 90.00 1.94723070e-01 1.30501339e-01 2.34409201e-01 0.59043746 0.09868255 90.25 2.88289864e-01 -2.50686070e-02 2.89377748e-01 -0.08673807 0.15207653 90.50 1.80805911e-01 -5.43645639e-02 1.88802234e-01 -0.29207973 0.07249522 90.75 5.03809783e-02 7.34528263e-02 8.90705376e-02 0.96959918 0.02826802 91.00 7.04808729e-02 1.00665629e-01 1.22886624e-01 0.95997082 0.05561389 91.25 1.76720623e-01 1.08114530e-01 2.07168845e-01 0.54903786 0.18221590 91.50 1.80805070e-01 -2.67746617e-02 1.82776792e-01 -0.14701734 0.10779633 91.75 8.77569138e-02 -2.12152077e-01 2.29586105e-01 -1.17857754 0.22737219 92.00 -7.85570066e-03 -2.18645460e-01 2.18786538e-01 -1.60670982 0.24975194 92.25 -8.45890722e-03 -1.54286913e-01 1.54518623e-01 -1.62556732 0.22075072 92.50 -1.90646707e-02 -1.09615676e-01 1.11261215e-01 -1.74299666 0.06054389 92.75 -3.40589053e-02 -1.00720692e-01 1.06323406e-01 -1.89687741 0.03633731 93.00 -8.03832062e-02 -1.43256779e-01 1.64267966e-01 -2.08213135 0.07960061 93.25 -1.49499717e-01 -2.82803213e-01 3.19887203e-01 -2.05708876 0.28251785 93.50 -2.15411483e-01 -3.44936993e-01 4.06673870e-01 -2.12903253 0.27450001 93.75 -3.67157906e-01 -3.57871138e-01 5.12715008e-01 -2.36900261 0.44576791 94.00 -3.86826175e-01 -1.79286737e-01 4.26354575e-01 -2.70758432 0.38453253 94.25 -3.67850842e-01 -9.00067193e-02 3.78702325e-01 -2.90162478 0.47643596 94.50 -3.64295588e-01 -1.51701527e-01 3.94619600e-01 -2.74700808 0.40286495 94.75 -3.76023443e-01 -2.02090394e-01 4.26888928e-01 -2.64844282 0.49493936 95.00 -3.08918831e-01 -2.51346515e-01 3.98253581e-01 -2.45859409 0.36398196 95.25 -2.84860812e-01 -3.54696797e-01 4.54923620e-01 -2.24743119 0.38685984 95.50 -4.88232895e-01 -5.11635814e-01 7.07207583e-01 -2.33279277 0.44601188 95.75 -7.54048902e-01 -6.33983570e-01 9.85152228e-01 -2.44248009 0.66794757 96.00 -1.12290340e+00 -4.84420672e-01 1.22293722e+00 -2.73431355 0.69248730 96.25 -1.16857991e+00 -3.01664857e-01 1.20688885e+00 -2.88896148 0.72688025 96.50 -1.10597316e+00 -1.96837019e-01 1.12335277e+00 -2.96546059 0.67822729 96.75 -1.15652995e+00 -2.93757783e-01 1.19325402e+00 -2.89285351 0.67087243 97.00 -1.62437437e+00 -3.36763459e-01 1.65891583e+00 -2.93716973 0.82510474 97.25 -1.80065475e+00 -3.22286102e-01 1.82926921e+00 -2.96448524 0.88600786 97.50 -2.13800048e+00 -9.49893763e-02 2.14010958e+00 -3.09719278 0.90484398 97.75 -2.30012190e+00 1.53842598e-02 2.30017335e+00 3.13490430 0.92956515 98.00 -2.61109467e+00 1.93277902e-01 2.61823829e+00 3.06770561 0.91698441 98.25 -2.81848264e+00 3.15812415e-01 2.83612092e+00 3.03000759 0.86453868 98.50 -2.21955004e+00 1.67893244e+00 2.78302291e+00 2.49398955 0.79406754 98.75 -1.70447362e+00 1.72919352e+00 2.42803224e+00 2.34899534 0.81897267 99.00 -1.83183170e+00 9.95118089e-01 2.08467441e+00 2.64395687 0.88906016 99.25 -2.05580586e+00 1.07788287e+00 2.32124303e+00 2.65868546 0.87851374 99.50 -2.94827427e+00 1.78911542e+00 3.44865991e+00 2.59616272 0.89098691 99.75 -3.07616621e+00 2.41022952e+00 3.90794126e+00 2.47698324 0.82413044 100.00 -2.74905807e+00 4.87855647e+00 5.59978871e+00 2.08394378 0.86082759 100.25 -1.74713222e+00 5.46365220e+00 5.73619790e+00 1.88029397 0.80399368 100.50 1.81753157e+00 5.38261025e+00 5.68118950e+00 1.24515027 0.84223362 100.75 2.23775641e+00 4.18211311e+00 4.74316601e+00 1.07948174 0.84336685 101.00 2.32624500e+00 2.56723848e+00 3.46440892e+00 0.83460624 0.90037308 101.25 2.32554521e+00 2.03313298e+00 3.08897883e+00 0.71841117 0.89295901 101.50 1.98126807e+00 1.39051858e+00 2.42052992e+00 0.61195486 0.92154272 101.75 1.87941699e+00 1.21016788e+00 2.23533321e+00 0.57207928 0.89983752 102.00 1.62077070e+00 9.26323480e-01 1.86680820e+00 0.51922462 0.90239331 102.25 1.50820074e+00 7.26902748e-01 1.67423328e+00 0.44911729 0.90390948 102.50 1.39551240e+00 4.76799220e-01 1.47471772e+00 0.32923117 0.91286373 102.75 1.15065906e+00 3.55599278e-01 1.20435340e+00 0.29972928 0.88492880 103.00 9.52990197e-01 2.70599407e-01 9.90663593e-01 0.27666567 0.91821803 103.25 8.81083570e-01 2.36130732e-01 9.12176507e-01 0.26184715 0.90727075 103.50 7.72436895e-01 2.00365598e-01 7.98000708e-01 0.25380047 0.92208581 103.75 6.78631437e-01 1.59441723e-01 6.97109955e-01 0.23076076 0.89948829 104.00 6.10668105e-01 1.12927832e-01 6.21021924e-01 0.18285930 0.93731353 104.25 5.32872594e-01 1.05828520e-01 5.43279741e-01 0.19604909 0.91222149 104.50 4.84986484e-01 1.14331409e-01 4.98280604e-01 0.23151448 0.92636383 104.75 4.35488461e-01 7.03900266e-02 4.41140517e-01 0.16024871 0.87969729 105.00 3.86154828e-01 5.27930201e-02 3.89746910e-01 0.13587230 0.88339976 105.25 2.82690584e-01 5.31041091e-02 2.87635207e-01 0.18568838 0.76621071 105.50 2.29385135e-01 5.23656086e-02 2.35286415e-01 0.22444070 0.79487840 105.75 1.66562298e-01 5.88339318e-02 1.76647759e-01 0.33954479 0.66938866 106.00 1.37726062e-01 6.18913935e-02 1.50993420e-01 0.42233855 0.73677960 106.25 7.47359598e-02 5.91927599e-02 9.53375398e-02 0.66985928 0.44125560 106.50 2.11986740e-02 6.19566029e-02 6.54828559e-02 1.24112866 0.35668261 106.75 -2.00294475e-02 6.57677848e-02 6.87501293e-02 1.86642036 0.31352934 107.00 -5.84783724e-02 7.25712126e-02 9.32003269e-02 2.24906795 0.38172047 107.25 -1.00075660e-01 1.06069083e-01 1.45827940e-01 2.32712882 0.60564101 107.50 -1.26982155e-01 1.17694275e-01 1.73136969e-01 2.39413612 0.72402583 107.75 -1.97852340e-01 1.72726102e-01 2.62640162e-01 2.42389362 0.80039764 108.00 -2.34367623e-01 1.97951876e-01 3.06778630e-01 2.44022953 0.85459166 108.25 -2.38724263e-01 2.73939318e-01 3.63362111e-01 2.28761184 0.85122869 108.50 -2.37701916e-01 3.11876084e-01 3.92133769e-01 2.22203947 0.87923045 108.75 -2.00237949e-01 4.18702714e-01 4.64119811e-01 2.01688015 0.86438914 109.00 -1.68716521e-01 4.41649614e-01 4.72778644e-01 1.93570240 0.88889856 109.25 -1.46056439e-01 3.96973951e-01 4.22990308e-01 1.92334943 0.88134990 109.50 -1.56085992e-01 4.12643799e-01 4.41177676e-01 1.93242063 0.88203818 109.75 -1.88937228e-01 4.20318860e-01 4.60831010e-01 1.99324209 0.90325428 110.00 -2.06075936e-01 4.11257831e-01 4.60000321e-01 2.03531312 0.78776668 110.25 -1.14020971e-01 6.34184129e-01 6.44352614e-01 1.74868739 0.60782690 110.50 1.47771026e-01 5.86906323e-01 6.05223354e-01 1.32414347 0.64678066 110.75 1.23775599e-01 3.92969553e-01 4.12001782e-01 1.26565821 0.85615495 111.00 7.74949716e-02 3.87773675e-01 3.95441391e-01 1.37354896 0.84201331 111.25 3.35143609e-03 4.04201641e-01 4.04215535e-01 1.56250502 0.80489543 111.50 4.24061107e-03 3.99783893e-01 3.99806383e-01 1.56018947 0.71796973 111.75 3.90187107e-02 3.70450953e-01 3.72500159e-01 1.46585565 0.68831324 112.00 1.13431627e-01 3.45318324e-01 3.63471428e-01 1.25341629 0.65854438 112.25 1.65210753e-01 2.98738523e-01 3.41378526e-01 1.06563137 0.70961166 112.50 1.90694364e-01 1.73789063e-01 2.58005773e-01 0.73904984 0.50967558 112.75 1.48425935e-01 2.57036333e-02 1.50635105e-01 0.17147417 0.36266553 113.00 2.92268790e-02 -4.30574607e-02 5.20399403e-02 -0.97444905 0.05675511 113.25 -1.35499975e-01 -9.23280618e-02 1.63965588e-01 -2.54346746 0.46743458 113.50 -2.93405854e-01 -4.66611487e-02 2.97093012e-01 -2.98388061 0.71564411 113.75 -4.44827257e-01 8.23951967e-03 4.44903561e-01 3.12307181 0.91815134 114.00 -4.61675620e-01 9.81238485e-02 4.71987995e-01 2.93217041 0.89927657 114.25 -4.30866297e-01 2.42547260e-01 4.94444071e-01 2.62887714 0.93992178 114.50 -4.02639347e-01 2.75546006e-01 4.87897577e-01 2.54144784 0.94561142 114.75 -3.88812985e-01 2.84667471e-01 4.81882876e-01 2.50961704 0.94876382 115.00 -3.88030892e-01 2.83498618e-01 4.80561588e-01 2.51061814 0.91472648 115.25 -4.24504395e-01 2.99622362e-01 5.19593630e-01 2.52697341 0.91354009 115.50 -4.52657472e-01 3.94949221e-01 6.00735944e-01 2.42417334 0.90429834 115.75 -4.26550180e-01 4.70692177e-01 6.35213492e-01 2.30703672 0.91261747 116.00 -3.04227628e-01 4.23074709e-01 5.21101390e-01 2.19421799 0.84914533 116.25 -2.45155207e-01 3.69334546e-01 4.43293450e-01 2.15679465 0.87481965 116.50 -3.09892241e-01 3.35329079e-01 4.56594779e-01 2.31679146 0.84042406 116.75 -3.57206847e-01 2.92272009e-01 4.61540528e-01 2.45584325 0.82705139 117.00 -5.00233436e-01 2.11448512e-01 5.43087436e-01 2.74167201 0.80343438 117.25 -6.27805245e-01 2.20964744e-01 6.65556041e-01 2.80316938 0.86715597 117.50 -7.93131474e-01 3.32443815e-01 8.59986294e-01 2.74468447 0.90093428 117.75 -9.03201718e-01 4.09397830e-01 9.91655145e-01 2.71601943 0.91914844 118.00 -1.17412044e+00 6.55725102e-01 1.34481754e+00 2.63226070 0.91641251 118.25 -1.36809625e+00 9.23816732e-01 1.65079517e+00 2.54766637 0.88616143 118.50 -1.47752840e+00 1.75941880e+00 2.29753013e+00 2.26932838 0.78347181 118.75 -7.16822670e-01 2.40791027e+00 2.51234285e+00 1.86013703 0.70042857 119.00 1.09382945e+00 2.09388664e+00 2.36237680e+00 1.08939608 0.78107592 119.25 1.17562830e+00 1.42055987e+00 1.84393390e+00 0.87946251 0.81372477 119.50 9.84759733e-01 6.48271589e-01 1.17898591e+00 0.58219092 0.82962548 119.75 8.08670265e-01 4.69877220e-01 9.35271190e-01 0.52636854 0.84938550 120.00 5.47983985e-01 3.26905831e-01 6.38086099e-01 0.53788693 0.85537085 120.25 4.85778406e-01 2.96729046e-01 5.69235265e-01 0.54834624 0.85725888 120.50 3.64204867e-01 2.43440501e-01 4.38073582e-01 0.58921297 0.80799160 120.75 2.94692763e-01 2.21274745e-01 3.68519114e-01 0.64405505 0.74211364 121.00 2.09727817e-01 1.75386184e-01 2.73397276e-01 0.69646076 0.62028966 121.25 1.00424176e-01 1.50433724e-01 1.80873769e-01 0.98217257 0.36910191 121.50 -8.94107274e-02 1.38478488e-01 1.64834977e-01 2.14411813 0.48803511 121.75 -1.47865009e-01 1.92504605e-01 2.42738715e-01 2.22578841 0.62013519 122.00 -2.55058142e-01 3.53123404e-01 4.35603941e-01 2.19632710 0.84491603 122.25 -2.63018588e-01 4.36790328e-01 5.09867206e-01 2.11280410 0.82628601 122.50 -2.51980070e-01 6.28200241e-01 6.76852642e-01 1.95226290 0.84181391 122.75 -1.78879120e-01 7.63666220e-01 7.84336557e-01 1.80088539 0.79146537 123.00 8.54980457e-02 1.02852397e+00 1.03207144e+00 1.48786007 0.79130559 123.25 5.06969283e-01 9.59851224e-01 1.08551012e+00 1.08486371 0.74068557 123.50 8.05951283e-01 5.56041113e-01 9.79152281e-01 0.60392811 0.74669650 123.75 5.75836530e-01 2.87100365e-01 6.43439452e-01 0.46251067 0.67368640 124.00 4.07278396e-01 1.80939841e-01 4.45662336e-01 0.41807510 0.80123646 124.25 3.62451200e-01 2.12102768e-01 4.19950541e-01 0.52945851 0.77643468 124.50 4.15666581e-01 2.78541733e-01 5.00364071e-01 0.59038167 0.87623904 124.75 5.16897782e-01 2.13191494e-01 5.59136772e-01 0.39118790 0.88207542 125.00 5.16270612e-01 8.78282918e-02 5.23688031e-01 0.16850742 0.87938353 125.25 4.42267345e-01 6.73564793e-03 4.42318633e-01 0.01522863 0.83303004 125.50 3.85806299e-01 -7.77795903e-02 3.93568501e-01 -0.19893614 0.84615964 125.75 3.09191835e-01 -1.68317720e-01 3.52037563e-01 -0.49851787 0.78981270 126.00 3.04946870e-01 -2.10848427e-01 3.70742030e-01 -0.60494891 0.84786437 126.25 2.39704339e-01 -2.88930960e-01 3.75418793e-01 -0.87825059 0.80584669 126.50 1.64964695e-01 -3.71564780e-01 4.06538727e-01 -1.15296583 0.86609148 126.75 1.03899033e-02 -3.86633434e-01 3.86773012e-01 -1.54393004 0.82504955 127.00 -7.26422584e-02 -3.43053717e-01 3.50660449e-01 -1.77946578 0.83720229 127.25 -1.67218684e-02 -2.76152857e-01 2.76658673e-01 -1.63127542 0.63379078 127.50 2.82222994e-02 -3.80640809e-01 3.81685635e-01 -1.49678757 0.71840503 127.75 -7.96095983e-02 -5.63969335e-01 5.69560443e-01 -1.71102924 0.83959072 128.00 -1.77456630e-01 -6.30844119e-01 6.55328283e-01 -1.84501038 0.88073104 128.25 -4.28889458e-01 -6.95367674e-01 8.16995942e-01 -2.12346339 0.87953964 128.50 -5.80090446e-01 -7.39898962e-01 9.40189024e-01 -2.23571283 0.89875417 128.75 -1.03100781e+00 -6.69646324e-01 1.22939144e+00 -2.56556440 0.81847346 129.00 -1.41632884e+00 -3.99524254e-01 1.47160015e+00 -2.86665215 0.84914758 129.25 -1.56309987e+00 2.91109824e-01 1.58997677e+00 2.95746336 0.92256696 129.50 -1.39002279e+00 4.63433746e-01 1.46524202e+00 2.81978200 0.92813400 129.75 -1.14009649e+00 8.05986311e-01 1.39622131e+00 2.52622034 0.95281801 130.00 -1.11334578e+00 9.29252280e-01 1.45018917e+00 2.44607877 0.95542768 130.25 -9.10105101e-01 1.38148646e+00 1.65432649e+00 2.15332381 0.92966310 130.50 -5.99890089e-01 1.62935893e+00 1.73628299e+00 1.92357052 0.86565804 130.75 4.49923142e-01 1.61442238e+00 1.67594464e+00 1.29900293 0.85570130 131.00 7.51423553e-01 1.12533244e+00 1.35314835e+00 0.98205466 0.84213761 131.25 5.82343626e-01 3.15489682e-01 6.62312492e-01 0.49649385 0.80853365 131.50 3.95861339e-01 2.62230567e-01 4.74837941e-01 0.58506404 0.80020530 131.75 2.49867643e-01 2.69662693e-01 3.67629986e-01 0.82348156 0.85505297 132.00 2.19916894e-01 2.29673217e-01 3.17983061e-01 0.80709524 0.83100959 132.25 2.08822310e-01 1.48760616e-01 2.56391260e-01 0.61898575 0.81060697 132.50 1.75894574e-01 9.98360909e-02 2.02252679e-01 0.51624802 0.63807183 132.75 4.25114972e-02 4.86643465e-02 6.46176912e-02 0.85277933 0.20666196 133.00 2.61106834e-02 7.36130672e-02 7.81066671e-02 1.22993903 0.33038220 133.25 1.41213835e-03 6.81040715e-02 6.81187103e-02 1.55006429 0.31145499 133.50 -1.36803995e-02 5.50988128e-02 5.67717579e-02 1.81416348 0.18396108 133.75 -2.50071409e-02 7.45905132e-02 7.86708444e-02 1.89427898 0.32975210 134.00 2.52222779e-02 7.70116941e-02 8.10368085e-02 1.25429381 0.22351538 134.25 7.32132906e-02 2.67240587e-03 7.32620479e-02 0.03648545 0.19682960 134.50 4.74504535e-02 -4.14383074e-02 6.29974512e-02 -0.71786428 0.17836448 134.75 4.66848958e-02 -4.05225752e-02 6.18187560e-02 -0.71485266 0.24059452 135.00 3.65358963e-02 -1.07349401e-01 1.13396497e-01 -1.24274806 0.47768223 135.25 2.54662612e-02 -1.58972252e-01 1.60999091e-01 -1.41195277 0.77503435 135.50 -1.19866532e-02 -2.09554677e-01 2.09897219e-01 -1.62793466 0.76744198 135.75 -5.37204477e-02 -3.00690110e-01 3.05451189e-01 -1.74758828 0.86556432 136.00 -1.23892839e-01 -3.59323430e-01 3.80082574e-01 -1.90282646 0.86607667 136.25 -1.87834487e-01 -4.18749223e-01 4.58947390e-01 -1.99245277 0.92297306 136.50 -3.15376641e-01 -4.84496722e-01 5.78099904e-01 -2.14782967 0.92422554 136.75 -4.16275538e-01 -5.28227909e-01 6.72539997e-01 -2.23821455 0.94781307 137.00 -6.36075597e-01 -5.37645345e-01 8.32859341e-01 -2.43986044 0.93434970 137.25 -8.38465869e-01 -4.92408366e-01 9.72363621e-01 -2.61058381 0.95166041 137.50 -1.02628589e+00 -2.36896145e-01 1.05327229e+00 -2.91473743 0.91274607 137.75 -1.06364945e+00 3.58270820e-02 1.06425267e+00 3.10792222 0.92229495 138.00 -8.96365188e-01 1.40914356e-01 9.07373907e-01 2.98566243 0.87249252 138.25 -7.38387193e-01 1.56836154e-01 7.54859739e-01 2.93229942 0.87659185 138.50 -7.15606319e-01 7.29316767e-02 7.19313168e-01 3.04002741 0.81107079 138.75 -7.44931414e-01 8.37189609e-02 7.49621022e-01 3.02967746 0.83470454 139.00 -8.06054453e-01 1.79719030e-01 8.25846663e-01 2.92221942 0.85690940 139.25 -8.20794365e-01 1.74512410e-01 8.39141211e-01 2.93209815 0.89037704 139.50 -9.30639898e-01 1.67353428e-01 9.45567443e-01 2.96366807 0.88834315 139.75 -1.02906446e+00 2.45610070e-01 1.05796879e+00 2.90730262 0.89404193 140.00 -1.07455248e+00 4.73746265e-01 1.17435027e+00 2.72635065 0.91378510 140.25 -1.06461942e+00 5.90400149e-01 1.21736882e+00 2.63525177 0.91851723 140.50 -1.14871090e+00 8.31223092e-01 1.41790993e+00 2.51519365 0.92282257 140.75 -1.16760385e+00 1.02030692e+00 1.55058858e+00 2.42341615 0.94185230 141.00 -1.24833835e+00 1.28168735e+00 1.78915374e+00 2.34301397 0.95337321 141.25 -1.24130816e+00 1.53669703e+00 1.97541988e+00 2.25026124 0.93082486 141.50 -8.03443658e-01 2.20593771e+00 2.34769736e+00 1.92008152 0.91772222 141.75 -2.18039622e-01 2.54026273e+00 2.54960311e+00 1.65641996 0.89463427 142.00 9.99598965e-01 2.49729492e+00 2.68992194e+00 1.19005489 0.89110872 142.25 1.37002012e+00 1.93000698e+00 2.36682954e+00 0.95348856 0.87769876 142.50 1.61342869e+00 1.03750932e+00 1.91822255e+00 0.57147130 0.90207973 142.75 1.51666522e+00 6.89104500e-01 1.66587467e+00 0.42646968 0.88780797 143.00 1.18536639e+00 3.08117722e-01 1.22475712e+00 0.25430679 0.88746228 143.25 1.06048508e+00 1.71222104e-01 1.07421861e+00 0.16007499 0.88562990 143.50 9.43317910e-01 5.91789329e-02 9.45172379e-01 0.06265277 0.89534149 143.75 8.58998610e-01 -7.93639723e-03 8.59035272e-01 -0.00923886 0.83957208 144.00 7.37936278e-01 -7.82179521e-02 7.42070077e-01 -0.10560124 0.86854153 144.25 7.05574067e-01 -1.15585143e-01 7.14978804e-01 -0.16237491 0.84440177 144.50 6.75585502e-01 -1.55344021e-01 6.93215360e-01 -0.22601125 0.88159355 144.75 6.27948895e-01 -1.78033084e-01 6.52698701e-01 -0.27626540 0.86326297 145.00 6.10606202e-01 -2.23817420e-01 6.50333893e-01 -0.35134154 0.89928795 145.25 6.19545240e-01 -2.90609211e-01 6.84317191e-01 -0.43859772 0.88145532 145.50 5.98834156e-01 -3.63724402e-01 7.00640983e-01 -0.54583381 0.90994409 145.75 5.89754973e-01 -4.31892494e-01 7.30987041e-01 -0.63209301 0.85451647 146.00 5.13991799e-01 -5.67534612e-01 7.65691260e-01 -0.83486449 0.83227495 146.25 5.22938494e-01 -6.85539540e-01 8.62223364e-01 -0.91914519 0.82709000 146.50 5.28149009e-01 -8.02463041e-01 9.60670759e-01 -0.98870616 0.90318943 146.75 4.33921907e-01 -8.95302072e-01 9.94914078e-01 -1.11949151 0.88323425 147.00 4.39469567e-01 -9.78193832e-01 1.07237898e+00 -1.14855268 0.90627724 147.25 3.63203995e-01 -1.24692318e+00 1.29874346e+00 -1.28735845 0.85663778 147.50 2.50093090e-01 -1.64661645e+00 1.66550061e+00 -1.42006530 0.86440709 147.75 -4.04324372e-01 -1.61086324e+00 1.66083069e+00 -1.81671460 0.78398003 148.00 -8.72271702e-01 -1.31454782e+00 1.57762286e+00 -2.15663998 0.82142699 148.25 -8.65052754e-01 -8.25614033e-01 1.19580717e+00 -2.37951758 0.71742361 148.50 -8.42422489e-01 -6.16024812e-01 1.04362935e+00 -2.51019733 0.79113830 148.75 -6.88068129e-01 -5.47592846e-01 8.79372319e-01 -2.46939282 0.78514416 149.00 -6.23580441e-01 -5.15395317e-01 8.09002410e-01 -2.45089494 0.84190283 149.25 -5.88156435e-01 -4.17476945e-01 7.21259309e-01 -2.52431578 0.83046691 149.50 -5.61035244e-01 -3.64790090e-01 6.69202776e-01 -2.56507062 0.84499834 149.75 -4.30699698e-01 -3.47414404e-01 5.53352508e-01 -2.46282334 0.71941675 150.00 -3.60095068e-01 -3.89528282e-01 5.30472186e-01 -2.31695065 0.64691744 150.25 -4.08948730e-01 -4.63981559e-01 6.18480356e-01 -2.29323403 0.76356743 150.50 -4.67232916e-01 -4.42425277e-01 6.43464625e-01 -2.38345912 0.79785927 150.75 -4.89964904e-01 -3.32792149e-01 5.92297410e-01 -2.54495209 0.77301361 151.00 -4.56217240e-01 -3.29692533e-01 5.62877728e-01 -2.51581625 0.77875073 151.25 -4.28641626e-01 -4.00043191e-01 5.86317490e-01 -2.39069143 0.81551370 151.50 -3.83925946e-01 -4.04105366e-01 5.57404950e-01 -2.33059270 0.78445590 151.75 -2.34979169e-01 -4.30262058e-01 4.90245498e-01 -2.07066374 0.78800160 152.00 -2.25165257e-01 -4.81346132e-01 5.31407087e-01 -2.00833931 0.78069515 152.25 -2.23004579e-01 -6.50298936e-01 6.87473452e-01 -1.90115552 0.81234678 152.50 -2.29895429e-01 -6.80762990e-01 7.18533338e-01 -1.89647405 0.78734215 152.75 -2.53945108e-01 -5.69045229e-01 6.23137698e-01 -1.99054009 0.73154545 153.00 -2.28452023e-01 -6.28614768e-01 6.68839931e-01 -1.91937741 0.75074139 153.25 -1.88924390e-01 -6.77802356e-01 7.03639438e-01 -1.84262771 0.70727802 153.50 -1.82231830e-01 -5.55525607e-01 5.84651297e-01 -1.88777081 0.65102943 153.75 -1.12462788e-01 -4.92726319e-01 5.05397966e-01 -1.79519816 0.74125475 154.00 -1.35516924e-02 -5.18122754e-01 5.18299949e-01 -1.59694573 0.78306922 154.25 1.12240970e-01 -5.98837185e-01 6.09265139e-01 -1.38551452 0.82179588 154.50 2.48125145e-01 -6.86697223e-01 7.30150096e-01 -1.22406276 0.80179925 154.75 4.14555090e-01 -9.01136750e-01 9.91919031e-01 -1.13962811 0.85180047 155.00 4.72164392e-01 -1.02939795e+00 1.13251903e+00 -1.14074749 0.78104241 155.25 4.37647870e-01 -1.18331277e+00 1.26165160e+00 -1.21654862 0.66784750 155.50 2.05623143e-01 -1.24756384e+00 1.26439568e+00 -1.40744520 0.61199992 155.75 1.56828823e-01 -1.38457850e+00 1.39343206e+00 -1.45800875 0.66103780 156.00 3.39791244e-01 -1.45801340e+00 1.49708422e+00 -1.34183232 0.62857219 156.25 8.22556489e-01 -1.70536813e+00 1.89337784e+00 -1.12138139 0.74573146 156.50 6.54656623e-01 -1.53306036e+00 1.66698811e+00 -1.16721090 0.41023315 156.75 1.52448228e-02 -1.28635340e+00 1.28644373e+00 -1.55894569 0.18770610 157.00 1.32839536e-01 -1.77157709e+00 1.77655051e+00 -1.49595261 0.40594497 157.25 2.09225648e-01 -2.35544014e+00 2.36471428e+00 -1.48220228 0.55357178 157.50 -3.55457706e-02 -2.35223898e+00 2.35250754e+00 -1.58590664 0.48427872 157.75 -4.09547268e-01 -2.76704805e+00 2.79719215e+00 -1.71773826 0.48552560 158.00 -9.00878330e-01 -3.26927532e+00 3.39112709e+00 -1.83968219 0.49581266 158.25 -1.43311640e+00 -3.37426244e+00 3.66598822e+00 -1.97242970 0.49400506 158.50 -3.53999947e+00 -2.01538824e+00 4.07349801e+00 -2.62403843 0.48430028 158.75 -4.42287035e+00 -1.06990569e+00 4.55043737e+00 -2.90424908 0.59772446 159.00 -2.92575177e+00 -2.11615046e-01 2.93339468e+00 -3.06938995 0.60447867 159.25 -2.09725773e+00 9.41660813e-02 2.09937067e+00 3.09672317 0.63090838 159.50 -1.18137056e+00 -1.95624181e-01 1.19745782e+00 -2.97749088 0.50808267 159.75 -8.79137244e-01 -2.54199215e-01 9.15150007e-01 -2.86012295 0.55568690 160.00 -4.23728085e-01 -6.11343952e-01 7.43832587e-01 -2.17688257 0.61335327 160.25 -2.25932687e-01 -7.34003444e-01 7.67988694e-01 -1.86940163 0.71077017 160.50 1.07334308e-01 -9.10847496e-01 9.17149832e-01 -1.45349724 0.80010240 160.75 2.54958734e-01 -9.82406917e-01 1.01495187e+00 -1.31687364 0.82922603 161.00 6.15977115e-01 -9.37993728e-01 1.12216756e+00 -0.98972801 0.82008189 161.25 7.96135952e-01 -9.02595742e-01 1.20354124e+00 -0.84798647 0.84369502 161.50 1.24406547e+00 -8.33322342e-01 1.49737271e+00 -0.59019494 0.86112713 161.75 1.49209515e+00 -8.08028768e-01 1.69683778e+00 -0.49632459 0.87934439 162.00 1.95529144e+00 -6.36508448e-01 2.05628491e+00 -0.31471231 0.87645454 162.25 2.31888652e+00 -7.14486172e-01 2.42646351e+00 -0.29888599 0.87365104 162.50 3.24012223e+00 -8.82774964e-01 3.35822627e+00 -0.26599501 0.88590682 162.75 3.41154065e+00 -1.28413286e+00 3.64521698e+00 -0.36000494 0.83670812 163.00 3.36218190e+00 -2.79388018e+00 4.37150244e+00 -0.69334329 0.73793848 163.25 2.28315269e+00 -2.92458437e+00 3.71025335e+00 -0.90794991 0.69840299 163.50 5.86724690e-01 -2.13722897e+00 2.21630177e+00 -1.30287094 0.69108427 163.75 5.41721371e-01 -1.73757819e+00 1.82006594e+00 -1.26857842 0.67601340 164.00 5.71092194e-01 -1.20146069e+00 1.33028346e+00 -1.12707749 0.72512296 164.25 5.72117507e-01 -9.53760907e-01 1.11219527e+00 -1.03048402 0.71450286 164.50 7.09075106e-01 -6.96788300e-01 9.94133513e-01 -0.77665870 0.78054370 164.75 8.70971708e-01 -5.39407013e-01 1.02447628e+00 -0.55450175 0.77375642 165.00 8.94611220e-01 -3.42702871e-01 9.58005477e-01 -0.36583095 0.80627407 165.25 9.35091894e-01 -2.49994847e-01 9.67932990e-01 -0.26123828 0.82947123 165.50 9.88489870e-01 -2.05454890e-01 1.00961574e+00 -0.20492947 0.89981107 165.75 9.81549369e-01 -8.58017651e-02 9.85292397e-01 -0.08719298 0.88249599 166.00 1.01904397e+00 8.18259953e-03 1.01907682e+00 0.00802951 0.92869546 166.25 9.72666660e-01 7.73686699e-02 9.75738870e-01 0.07937572 0.91104849 166.50 9.16951740e-01 1.52919965e-01 9.29615516e-01 0.16524914 0.93283749 166.75 9.18048331e-01 2.51633679e-01 9.51909789e-01 0.26752588 0.90835219 167.00 9.47826418e-01 4.47143542e-01 1.04800394e+00 0.44079884 0.90964929 167.25 8.78567428e-01 5.91656347e-01 1.05921573e+00 0.59267241 0.84349900 167.50 9.26227993e-01 7.77181207e-01 1.20909426e+00 0.69812134 0.77758783 167.75 1.47052623e+00 6.68540008e-01 1.61536161e+00 0.42669455 0.76421036 168.00 1.78900109e+00 5.44977655e-01 1.87016725e+00 0.29569613 0.83307696 168.25 1.80721285e+00 2.61057998e-01 1.82597085e+00 0.14346101 0.88806610 168.50 1.86836856e+00 1.33119110e-01 1.87310484e+00 0.07112865 0.93715641 168.75 1.71175776e+00 2.67453863e-02 1.71196669e+00 0.01562324 0.94560161 169.00 1.70620322e+00 2.65797067e-02 1.70641024e+00 0.01557702 0.94915723 169.25 1.81087248e+00 -6.81492808e-02 1.81215437e+00 -0.03761564 0.92364732 169.50 1.84182910e+00 -2.43705946e-01 1.85788241e+00 -0.13155316 0.91079523 169.75 1.83917368e+00 -3.90900264e-01 1.88025606e+00 -0.20942486 0.88612185 170.00 1.94072718e+00 -5.20620945e-01 2.00934520e+00 -0.26209006 0.89437205 170.25 2.04854704e+00 -1.07672934e+00 2.31427981e+00 -0.48392222 0.86454604 170.50 2.09162964e+00 -1.49128730e+00 2.56882314e+00 -0.61938347 0.85041929 170.75 8.53783090e-01 -2.48337462e+00 2.62604171e+00 -1.23965593 0.69005538 171.00 -3.21126782e-01 -2.39375723e+00 2.41520104e+00 -1.70415192 0.69751887 171.25 -1.42141705e+00 -9.20841187e-01 1.69362774e+00 -2.56674216 0.62974144 171.50 -1.30216123e+00 -3.57009970e-01 1.35021479e+00 -2.87400080 0.68345995 171.75 -1.02575564e+00 -4.56008708e-02 1.02676875e+00 -3.09716602 0.65116778 172.00 -8.07855542e-01 1.02824736e-02 8.07920978e-01 3.12886523 0.48205483 172.25 -2.49478243e-01 -3.87615529e-01 4.60961161e-01 -2.14267547 0.11868119 172.50 -9.15735450e-02 -5.53475999e-01 5.61000352e-01 -1.73476264 0.17789280 172.75 2.61047560e-01 -1.71602816e-01 3.12399352e-01 -0.58153340 0.12016794 173.00 3.45881765e-01 -6.79780482e-02 3.52498525e-01 -0.19406211 0.18537525 173.25 1.81443719e-01 9.24835375e-02 2.03654187e-01 0.47138479 0.11241407 173.50 1.98142729e-01 1.64538063e-01 2.57552548e-01 0.69300565 0.13879377 173.75 1.42966280e-01 2.49579981e-01 2.87627405e-01 1.05059626 0.08762324 174.00 5.24051303e-02 2.73146145e-02 5.90964114e-02 0.48047933 0.00304857 174.25 2.14952131e-01 -4.41868230e-01 4.91377606e-01 -1.11803760 0.36088957 174.50 2.79398154e-01 -2.93407862e-01 4.05156145e-01 -0.80985132 0.51021025 174.75 3.15777393e-01 -8.45829718e-02 3.26909225e-01 -0.26171274 0.59044648 175.00 3.62559666e-01 2.67111795e-03 3.62569505e-01 0.00736726 0.63672555 175.25 3.85052266e-01 5.34062832e-02 3.88738317e-01 0.13781952 0.73245768 175.50 3.96978371e-01 1.07595919e-01 4.11301239e-01 0.26467834 0.74504282 175.75 4.56730374e-01 1.59177387e-01 4.83673522e-01 0.33535127 0.81176361 176.00 5.19353501e-01 2.03346862e-01 5.57743674e-01 0.37319072 0.81723313 176.25 6.00500402e-01 2.46270048e-01 6.49037495e-01 0.38918973 0.90688500 176.50 6.56857292e-01 2.34397780e-01 6.97426570e-01 0.34276183 0.91946664 176.75 7.09970062e-01 2.01833836e-01 7.38101881e-01 0.27697774 0.93602372 177.00 7.47481456e-01 1.39165191e-01 7.60325903e-01 0.18407130 0.92860802 177.25 7.89805000e-01 8.63913364e-02 7.94515829e-01 0.10894998 0.94729553 177.50 8.44016272e-01 1.98895468e-02 8.44250591e-01 0.02356100 0.93694489 177.75 8.96489377e-01 -2.59737949e-02 8.96865565e-01 -0.02896468 0.94914965 178.00 9.81081383e-01 -6.26680211e-02 9.83080852e-01 -0.06378981 0.94178632 178.25 1.05550801e+00 -1.53418872e-01 1.06659951e+00 -0.14433992 0.93222725 178.50 1.23828683e+00 -3.72310374e-01 1.29304652e+00 -0.29206741 0.83320769 178.75 1.47235040e+00 -7.20531457e-01 1.63920142e+00 -0.45511153 0.83404724 179.00 9.75420826e-01 -1.79123849e+00 2.03960317e+00 -1.07214618 0.71501656 179.25 2.95875672e-01 -2.04978285e+00 2.07102683e+00 -1.42744159 0.76183964 179.50 -6.55084083e-01 -1.40232903e+00 1.54779258e+00 -2.00781216 0.71259039 179.75 -8.56964463e-01 -1.20022651e+00 1.47476499e+00 -2.19085811 0.86097027 180.00 -8.59898180e-01 -8.27720611e-01 1.19354359e+00 -2.37525903 0.86858194 180.25 -8.85519820e-01 -6.54655406e-01 1.10123524e+00 -2.50498165 0.88095194 180.50 -8.04391696e-01 -3.66786893e-01 8.84069356e-01 -2.71377652 0.82016233 180.75 -7.72886611e-01 -2.52694273e-01 8.13147041e-01 -2.82559923 0.86091348 181.00 -7.22024731e-01 -1.02729117e-01 7.29296225e-01 -3.00026201 0.86702009 181.25 -6.95918128e-01 -5.04254536e-02 6.97742623e-01 -3.06926018 0.86039884 181.50 -5.51012112e-01 -4.08065615e-02 5.52521062e-01 -3.06767013 0.77604995 181.75 -5.38537188e-01 -2.55940455e-03 5.38543269e-01 -3.13684018 0.78123579 182.00 -5.72520738e-01 -5.31413076e-02 5.74981734e-01 -3.04903797 0.82684081 182.25 -5.79050886e-01 -7.59462785e-02 5.84010074e-01 -3.01118055 0.86437317 182.50 -5.94385408e-01 -6.49882966e-02 5.97927664e-01 -3.03268828 0.85234437 182.75 -6.43747176e-01 -6.11061785e-02 6.46640852e-01 -3.04695358 0.82940174 183.00 -7.29839591e-01 -2.63144887e-02 7.30313824e-01 -3.10555310 0.85628333 183.25 -7.62391041e-01 5.02154786e-02 7.64042992e-01 3.07582188 0.85035593 183.50 -8.20058585e-01 2.47225431e-01 8.56514155e-01 2.84878513 0.84428124 183.75 -8.60021507e-01 3.11372625e-01 9.14652888e-01 2.79422157 0.84605477 184.00 -9.66631705e-01 4.18766275e-01 1.05344295e+00 2.73277843 0.87623211 184.25 -9.56153145e-01 5.07323900e-01 1.08240768e+00 2.65377471 0.84096477 184.50 -1.03241873e+00 7.73233870e-01 1.28987560e+00 2.49876149 0.83995506 184.75 -1.02304314e+00 1.05929325e+00 1.47265728e+00 2.33878787 0.84401618 185.00 -8.45214834e-01 1.60725463e+00 1.81594481e+00 2.05492893 0.82408712 185.25 -1.86760352e-01 1.82397905e+00 1.83351547e+00 1.67283245 0.65747507 185.50 1.28386236e+00 1.46093541e+00 1.94489970e+00 0.84982113 0.69404059 185.75 1.32834130e+00 5.62332933e-01 1.44246627e+00 0.40045926 0.57423832 186.00 6.88127097e-01 -3.61519729e-01 7.77312946e-01 -0.48373518 0.62634042 186.25 3.78530471e-01 -2.76656320e-01 4.68853961e-01 -0.63114465 0.48655298 186.50 1.03081358e-01 -2.30842158e-01 2.52811923e-01 -1.15081949 0.39905845 186.75 -3.05659825e-02 -2.09392666e-01 2.11611833e-01 -1.71574702 0.38398141 187.00 -9.80087429e-02 -1.67518302e-01 1.94082702e-01 -2.10016025 0.49941462 187.25 -1.53461311e-01 -9.80274132e-02 1.82098182e-01 -2.57314823 0.44061898 187.50 -2.28665619e-01 -3.80365880e-02 2.31807565e-01 -2.97676035 0.68892083 187.75 -2.45571520e-01 -9.41600386e-03 2.45751974e-01 -3.10326820 0.71847873 188.00 -2.66030665e-01 1.71922896e-02 2.66585614e-01 3.07705718 0.80561396 188.25 -2.65989839e-01 3.70106175e-02 2.68552379e-01 3.00333736 0.75295052 188.50 -2.59948881e-01 5.31149568e-02 2.65319844e-01 2.94003859 0.75497117 188.75 -2.41172753e-01 7.14019164e-02 2.51520438e-01 2.85375326 0.73238186 189.00 -2.31377567e-01 8.42098023e-02 2.46225241e-01 2.79254491 0.75143816 189.25 -2.38131401e-01 7.95653902e-02 2.51072132e-01 2.81913077 0.64670541 189.50 -2.33308060e-01 4.95773130e-02 2.38517422e-01 2.93220992 0.58461658 189.75 -2.04146791e-01 6.68241055e-02 2.14805431e-01 2.82525154 0.43383866 190.00 -1.76001578e-01 7.98766829e-02 1.93279176e-01 2.71554938 0.37467344 190.25 -1.68002222e-01 1.53833725e-01 2.27792804e-01 2.40019005 0.46976776 190.50 -1.79074493e-01 1.62499107e-01 2.41813221e-01 2.40468300 0.62726237 190.75 -1.95227977e-01 1.68805582e-01 2.58087751e-01 2.42864974 0.72230037 191.00 -2.06828019e-01 1.99955498e-01 2.87680431e-01 2.37308767 0.77665176 191.25 -2.34718566e-01 2.68621334e-01 3.56721497e-01 2.28894046 0.77459368 191.50 -2.24308128e-01 3.15440313e-01 3.87061658e-01 2.18893006 0.76782630 191.75 -1.14831078e-01 3.34232140e-01 3.53408121e-01 1.90172859 0.68071544 192.00 -5.64711771e-02 3.07018730e-01 3.12169016e-01 1.75269715 0.63476677 192.25 -4.34722329e-02 2.21037526e-01 2.25271887e-01 1.76499133 0.44934910 192.50 -4.13719541e-02 1.87414535e-01 1.91926669e-01 1.78806289 0.33938591 192.75 -7.78428191e-02 1.42073449e-01 1.62001140e-01 2.07203003 0.20113372 193.00 -1.19761036e-01 1.62934979e-01 2.02214028e-01 2.20464336 0.23803171 193.25 -1.56497709e-01 2.60602385e-01 3.03982131e-01 2.11160025 0.44996452 193.50 -1.25215964e-01 3.01019526e-01 3.26024221e-01 1.96499616 0.45540148 193.75 -6.53556914e-02 3.51957089e-01 3.57973685e-01 1.75439732 0.52014922 194.00 -2.24794312e-02 3.54286038e-01 3.54998481e-01 1.63416133 0.50847701 194.25 1.77670110e-02 3.72767874e-01 3.73191043e-01 1.52316997 0.65821472 194.50 4.77372265e-02 3.62767690e-01 3.65895121e-01 1.43995637 0.63959233 194.75 5.22626211e-02 2.91877783e-01 2.96519850e-01 1.39361741 0.56804099 195.00 3.15935467e-02 2.65477316e-01 2.67350626e-01 1.45234684 0.53383186 195.25 7.12421258e-02 2.58228778e-01 2.67875983e-01 1.30160508 0.68200887 195.50 8.96694682e-02 2.54829184e-01 2.70145380e-01 1.23244705 0.68114374 195.75 5.82919767e-02 2.36726448e-01 2.43797797e-01 1.32935779 0.61246155 196.00 3.67569068e-02 2.29995329e-01 2.32913978e-01 1.41232059 0.51180069 196.25 4.54235678e-02 1.83269062e-01 1.88814326e-01 1.32784051 0.36949779 196.50 6.94700713e-02 1.00091889e-01 1.21837913e-01 0.96406609 0.19690219 196.75 6.47573371e-02 3.78296129e-02 7.49972820e-02 0.52870215 0.14228410 197.00 -1.84174107e-02 -3.98143897e-02 4.38678316e-02 -2.00406385 0.03962473 197.25 -1.07397569e-01 -9.33320090e-02 1.42285283e-01 -2.42615232 0.49928516 197.50 -2.14144217e-01 -7.28737461e-02 2.26204174e-01 -2.81358329 0.50032334 197.75 -3.89186421e-01 3.54097585e-02 3.90793962e-01 3.05085842 0.75796721 198.00 -4.74318290e-01 1.50295523e-01 4.97560634e-01 2.83473483 0.78272580 198.25 -5.01945123e-01 2.83283855e-01 5.76366766e-01 2.62778215 0.82295223 198.50 -3.80056595e-01 4.11789109e-01 5.60368883e-01 2.31614181 0.65893298 198.75 -2.79206225e-01 6.87620477e-01 7.42144215e-01 1.95650473 0.72737646 199.00 -4.33079648e-02 6.74891897e-01 6.76280010e-01 1.63487869 0.73477903 199.25 8.90173116e-02 7.18472472e-01 7.23966004e-01 1.44752651 0.81514722 199.50 2.86383972e-01 7.15306156e-01 7.70505468e-01 1.18997483 0.75075286 199.75 3.70922661e-01 7.17413443e-01 8.07629660e-01 1.09361949 0.79302992 200.00 4.41121744e-01 5.13123143e-01 6.76671082e-01 0.86070925 0.72587434 200.25 5.45968044e-01 2.91768832e-01 6.19039705e-01 0.49079241 0.71814962 200.50 4.98825164e-01 9.28100510e-03 4.98911496e-01 0.01860358 0.50632754 200.75 4.50648176e-01 -2.00444358e-01 4.93215693e-01 -0.41851388 0.51807935 201.00 2.01062831e-01 -3.14581002e-01 3.73346312e-01 -1.00209003 0.26392614 201.25 6.60629161e-02 -3.61623563e-01 3.67608365e-01 -1.39010464 0.29243773 201.50 -9.41987073e-02 -1.32708986e-01 1.62742347e-01 -2.18807860 0.08098541 201.75 -1.25040412e-01 -4.31311509e-02 1.32270181e-01 -2.80943479 0.06004398 202.00 -1.12945374e-01 -1.00054591e-02 1.13387683e-01 -3.05323659 0.04086964 202.25 -1.37907074e-01 -2.95182476e-02 1.41030805e-01 -2.93072998 0.07067554 202.50 -9.36764582e-02 -1.26621516e-02 9.45283497e-02 -3.00723797 0.03758947 202.75 -1.14104726e-01 -3.43853703e-02 1.19173161e-01 -2.84889850 0.05687103 203.00 -9.24194343e-02 -5.34469651e-02 1.06761088e-01 -2.61727534 0.03732104 203.25 -6.91725417e-02 -1.16729040e-01 1.35685332e-01 -2.10574999 0.06100995 203.50 -9.46605569e-02 -1.10299698e-01 1.45350075e-01 -2.28003877 0.05608811 203.75 -7.81732989e-02 -3.88562589e-02 8.72976146e-02 -2.68030556 0.02219069 204.00 1.87929945e-02 4.68064123e-02 5.04382482e-02 1.18899347 0.00727552 204.25 3.97901895e-02 1.77533704e-02 4.35711067e-02 0.41966814 0.00518444 204.50 1.77241677e-01 -8.18347877e-02 1.95221783e-01 -0.43255166 0.06734165 204.75 2.95094531e-01 -6.62459958e-02 3.02438943e-01 -0.22082969 0.13564315 205.00 3.09152491e-01 -1.40819755e-01 3.39713800e-01 -0.42742044 0.14665486 205.25 2.42329108e-01 -1.36396754e-01 2.78078175e-01 -0.51266099 0.09013941 205.50 3.79999970e-01 -3.27565312e-02 3.81409187e-01 -0.08598884 0.13491735 205.75 1.74044918e-01 -1.04298075e-02 1.74357146e-01 -0.05985437 0.02857940 206.00 6.17670359e-02 9.53366467e-04 6.17743930e-02 0.01543365 0.00283642 206.25 -1.71054814e-02 8.02088795e-02 8.20125713e-02 1.78091039 0.00498149 206.50 -1.22883577e-01 1.96257628e-01 2.31554378e-01 2.13021070 0.02818705 206.75 -6.98922159e-02 1.84568708e-01 1.97358886e-01 1.93278814 0.02660005 207.00 -6.42918916e-02 2.18992685e-01 2.28235062e-01 1.85635294 0.04208236 207.25 2.03431884e-02 1.81055768e-01 1.82195051e-01 1.45890691 0.04103286 207.50 1.13735804e-01 1.28639571e-01 1.71708976e-01 0.84681127 0.04207913 207.75 9.10832495e-02 1.46255298e-01 1.72298493e-01 1.01380302 0.03678332 208.00 6.28841353e-02 1.56707222e-01 1.68853688e-01 1.18918336 0.03360540 208.25 1.97529423e-03 4.01857950e-02 4.02343126e-02 1.52168182 0.00199392 208.50 1.56326924e-02 -2.11181672e-01 2.11759486e-01 -1.49690624 0.06243608 208.75 1.34250986e-02 -1.46211032e-01 1.46826085e-01 -1.47923306 0.02191379 209.00 -3.15361625e-02 5.11504423e-02 6.00907421e-02 2.12328704 0.00235501 209.25 -2.20471914e-01 3.36080141e-02 2.23018752e-01 2.99032047 0.05412339 209.50 -3.72807597e-01 -5.34004347e-02 3.76612680e-01 -2.99932180 0.12624798 209.75 -2.89077939e-01 5.38664409e-02 2.94053819e-01 2.95736669 0.06176945 210.00 -2.67038038e-01 1.86990081e-01 3.25997859e-01 2.53070723 0.07455098 210.25 -2.40473847e-01 2.70349426e-01 3.61823829e-01 2.29777588 0.11008545 210.50 -1.84328422e-01 2.31170517e-01 2.95663280e-01 2.24393152 0.07733127 210.75 -2.81759940e-02 1.64087992e-01 1.66489507e-01 1.74085062 0.03009295 211.00 5.62649592e-02 7.26805495e-02 9.19141334e-02 0.91202344 0.00942295 211.25 -6.11325123e-02 -6.06236190e-02 8.60953381e-02 -2.36037408 0.00767650 211.50 -3.87930017e-02 -1.25379604e-01 1.31243826e-01 -1.87085853 0.01721401 211.75 -2.49619183e-01 -2.76557045e-02 2.51146520e-01 -3.03125107 0.06250656 212.00 -3.01088240e-01 7.60980351e-03 3.01184391e-01 3.11632370 0.07556336 212.25 -8.53888554e-02 3.68587637e-02 9.30044358e-02 2.73409635 0.00781200 212.50 -6.57593838e-02 7.40441057e-02 9.90294206e-02 2.29700395 0.00914361 212.75 -1.92712372e-01 -5.84623760e-02 2.01384974e-01 -2.84705068 0.02941451 213.00 -3.13923319e-01 -1.87732809e-01 3.65775146e-01 -2.60262940 0.08502190 213.25 -1.56720868e-01 -6.07727759e-02 1.68091525e-01 -2.77166740 0.02080495 213.50 -1.04495161e-01 6.28069406e-02 1.21917802e-01 2.60040058 0.01361293 213.75 -2.96501811e-01 2.34387212e-01 3.77955935e-01 2.47266605 0.11138940 214.00 -3.34721791e-01 1.63010755e-01 3.72305229e-01 2.68839603 0.12169355 214.25 -3.41099690e-01 6.65053533e-02 3.47522605e-01 2.94903504 0.10847659 214.50 -2.19395428e-01 1.78464793e-02 2.20120082e-01 3.06042746 0.04698297 214.75 -2.32844719e-01 -2.41657359e-01 3.35581499e-01 -2.33762423 0.06695753 215.00 -2.50016684e-01 -3.71274064e-01 4.47607833e-01 -2.16344734 0.11379499 215.25 -2.31093579e-01 -4.38858793e-01 4.95985163e-01 -2.05547991 0.14815777 215.50 -2.18022312e-01 -3.37505839e-01 4.01800846e-01 -2.14434095 0.09272352 215.75 -3.38202332e-01 -4.15827922e-01 5.35997834e-01 -2.25360830 0.13947525 216.00 -3.73065923e-01 -2.35484112e-01 4.41169978e-01 -2.57853793 0.09654179 216.25 -2.46552547e-01 -3.52617051e-02 2.49061331e-01 -2.99953696 0.03051832 216.50 -2.60176588e-01 1.49072359e-01 2.99857341e-01 2.62128827 0.04928127 216.75 -4.48859887e-01 2.68627484e-01 5.23102211e-01 2.60230169 0.12263098 217.00 -3.22377238e-01 3.81952542e-01 4.99814794e-01 2.27181096 0.10439421 217.25 -4.39401478e-01 6.09915386e-01 7.51711672e-01 2.19510266 0.21147117 217.50 -3.77642383e-01 4.17101218e-01 5.62660818e-01 2.30658546 0.17472100 217.75 -4.64131169e-01 5.13201128e-01 6.91948798e-01 2.30602855 0.35206704 218.00 -5.15276759e-01 5.14036460e-01 7.27834886e-01 2.35739947 0.38562189 218.25 -7.04022332e-01 6.03287099e-01 9.27147652e-01 2.43309791 0.52960223 218.50 -6.89281810e-01 5.76356713e-01 8.98496786e-01 2.44518266 0.55077841 218.75 -7.41440367e-01 6.33767880e-01 9.75395071e-01 2.43433049 0.62757171 219.00 -7.30320356e-01 6.16945905e-01 9.56028280e-01 2.44014817 0.64835243 219.25 -8.25900258e-01 5.24340631e-01 9.78286427e-01 2.57592612 0.76985461 219.50 -8.33480749e-01 4.44595711e-01 9.44645703e-01 2.65156747 0.71230453 219.75 -8.26569359e-01 4.58064477e-01 9.45007921e-01 2.63554935 0.73383644 220.00 -8.46788410e-01 4.78370295e-01 9.72568122e-01 2.62736444 0.79700118 220.25 -9.34029939e-01 4.39067256e-01 1.03208138e+00 2.70216759 0.85926007 220.50 -1.02557279e+00 3.42902331e-01 1.08137947e+00 2.81892557 0.88332169 220.75 -1.08687697e+00 3.48881032e-01 1.14149880e+00 2.83098826 0.90497619 221.00 -1.12074576e+00 4.12239973e-01 1.19415780e+00 2.78912588 0.82754221 221.25 -1.21757260e+00 5.22035623e-01 1.32476573e+00 2.73654906 0.82465003 221.50 -1.01307592e+00 5.37741229e-01 1.14694745e+00 2.65360931 0.77800660 221.75 -9.11138252e-01 4.93621164e-01 1.03625999e+00 2.64509528 0.80190093 222.00 -9.36096258e-01 4.82514554e-01 1.05313651e+00 2.66565842 0.79071470 222.25 -9.62443201e-01 5.32866873e-01 1.10011091e+00 2.63594335 0.80839366 222.50 -9.42963967e-01 5.16921494e-01 1.07535523e+00 2.64014171 0.81099325 222.75 -8.91132350e-01 5.44365280e-01 1.04424634e+00 2.59321942 0.82704514 223.00 -7.63106305e-01 4.18349499e-01 8.70257166e-01 2.64011772 0.81960925 223.25 -7.86460386e-01 4.10700722e-01 8.87240115e-01 2.66033209 0.84520067 223.50 -8.46539098e-01 3.77885530e-01 9.27052274e-01 2.72174590 0.89393989 223.75 -8.50730196e-01 3.33370060e-01 9.13716292e-01 2.76812017 0.90722890 224.00 -8.29186562e-01 2.58903162e-01 8.68666335e-01 2.83894692 0.89778032 224.25 -8.10203524e-01 2.01806740e-01 8.34958509e-01 2.89747861 0.88895503 224.50 -9.56448598e-01 6.78448317e-02 9.58851836e-01 3.07077716 0.86824090 224.75 -1.05681607e+00 4.89174731e-02 1.05794760e+00 3.09533808 0.88167983 225.00 -1.18942958e+00 6.37679428e-02 1.19113773e+00 3.08803173 0.92484853 225.25 -1.22846603e+00 1.88135561e-02 1.22861009e+00 3.12627918 0.92295021 225.50 -1.28894818e+00 -1.22286539e-01 1.29473603e+00 -3.04700265 0.93270196 225.75 -1.33755126e+00 -1.50695127e-01 1.34601352e+00 -3.02940082 0.91613221 226.00 -1.46220670e+00 -1.79663126e-01 1.47320307e+00 -3.01933423 0.89216699 226.25 -1.53350860e+00 -2.73729402e-01 1.55774722e+00 -2.96495421 0.82761702 226.50 -2.01954894e+00 -3.08496267e-02 2.01978455e+00 -3.12631834 0.73932546 226.75 -1.80856950e+00 4.58805552e-01 1.86585803e+00 2.89314950 0.73923253 227.00 -1.75595002e+00 6.05736035e-01 1.85749202e+00 2.80941306 0.83399473 227.25 -1.68899210e+00 3.66945212e-01 1.72839321e+00 2.92766030 0.75218692 227.50 -1.68187744e+00 4.56811027e-02 1.68249770e+00 3.11443855 0.78018334 227.75 -1.95721778e+00 1.64512472e-01 1.96411960e+00 3.05773552 0.74716361 228.00 -2.54157947e+00 4.96766199e-01 2.58967235e+00 2.94857041 0.76321496 228.25 -2.76356643e+00 7.42078557e-01 2.86146466e+00 2.87925885 0.71275615 228.50 -2.88222238e+00 9.97298660e-01 3.04988696e+00 2.80847034 0.66669742 228.75 -1.86885792e+00 1.46959616e+00 2.37746562e+00 2.47522395 0.54314204 229.00 -1.27530535e+00 1.82333782e+00 2.22507630e+00 2.18114265 0.52452139 229.25 -6.66597594e-01 1.02450148e+00 1.22227477e+00 2.14763227 0.35880652 229.50 -7.44237774e-01 8.99471864e-01 1.16745000e+00 2.26203247 0.52151093 229.75 -1.19874884e+00 9.25931244e-01 1.51471035e+00 2.48389978 0.63651875 230.00 -1.66347975e+00 9.85507789e-01 1.93349178e+00 2.60675237 0.76265670 230.25 -1.65292875e+00 1.17607439e+00 2.02862624e+00 2.52318393 0.66978698 230.50 -1.86259561e+00 1.53665695e+00 2.41465877e+00 2.45178763 0.70783245 230.75 -1.30602214e+00 1.59991770e+00 2.06529186e+00 2.25540107 0.64336926 231.00 -1.13063721e+00 1.73493564e+00 2.07083127e+00 2.14835747 0.65734490 231.25 -6.93389050e-01 1.62492671e+00 1.76668480e+00 1.97412310 0.65110082 231.50 -6.04091847e-01 1.68626299e+00 1.79120346e+00 1.91479559 0.69630390 231.75 -4.85056232e-01 1.18002586e+00 1.27582937e+00 1.96079691 0.51028287 232.00 -3.88465806e-01 1.13921131e+00 1.20362290e+00 1.89942681 0.46466433 232.25 -4.03118703e-01 9.38962602e-01 1.02183925e+00 1.97632330 0.51496479 232.50 -5.02679964e-01 8.89852059e-01 1.02201949e+00 2.08500922 0.58440425 232.75 -5.69051337e-01 6.88333717e-01 8.93097268e-01 2.26161211 0.52905406 233.00 -6.73416600e-01 6.23461238e-01 9.17711192e-01 2.39469517 0.58130875 233.25 -8.17279562e-01 6.15510570e-01 1.02313203e+00 2.49609696 0.62588366 233.50 -9.67636976e-01 6.96229534e-01 1.19208090e+00 2.51788894 0.69738010 233.75 -1.21479693e+00 5.68766275e-01 1.34135254e+00 2.70370822 0.61838429 234.00 -1.32120299e+00 6.16489868e-01 1.45795648e+00 2.70500995 0.58617279 234.25 -1.41482573e+00 8.04412181e-01 1.62751676e+00 2.62461228 0.56705763 234.50 -1.58470314e+00 9.81149836e-01 1.86385060e+00 2.58721986 0.66269610 234.75 -2.05760629e+00 1.29880395e+00 2.43323557e+00 2.57853243 0.75478643 235.00 -2.10453128e+00 1.49362817e+00 2.58069312e+00 2.52437287 0.76989282 235.25 -2.08618177e+00 1.44746441e+00 2.53915489e+00 2.53501676 0.76849863 235.50 -2.21604335e+00 1.45537410e+00 2.65121895e+00 2.56049079 0.77273969 235.75 -2.52793779e+00 1.78875133e+00 3.09678878e+00 2.52578881 0.86728114 236.00 -2.62644847e+00 1.74909802e+00 3.15556262e+00 2.55408250 0.86943144 236.25 -2.93056303e+00 2.04330151e+00 3.57257341e+00 2.53272242 0.86599961 236.50 -2.95229092e+00 2.36736636e+00 3.78423641e+00 2.46570986 0.83223574 236.75 -2.50588121e+00 2.98069985e+00 3.89409967e+00 2.26986777 0.83454378 237.00 -2.19255511e+00 2.63642162e+00 3.42899648e+00 2.26453475 0.76679803 237.25 -2.88654671e+00 1.97701543e+00 3.49867717e+00 2.54106835 0.73552180 237.50 -2.95434369e+00 1.66532182e+00 3.39137780e+00 2.62830280 0.63231514 237.75 -3.65948847e+00 1.22639127e+00 3.85951958e+00 2.81822919 0.59012592 238.00 -2.54581990e+00 7.71914915e-01 2.66027284e+00 2.84719464 0.26461079 238.25 -5.40110858e-01 -3.48713787e-01 6.42900493e-01 -2.56829300 0.00897156 238.50 1.42764732e+00 -3.93423833e-01 1.48086433e+00 -0.26890066 0.05843989 238.75 3.66129761e+00 -3.87521710e-01 3.68174867e+00 -0.10545012 0.35784030 239.00 2.86184416e+00 -2.86078816e-01 2.87610728e+00 -0.09963212 0.41496987 239.25 2.50457604e+00 -1.90128398e-01 2.51178223e+00 -0.07576709 0.60270775 239.50 2.07161704e+00 3.44096850e-01 2.09999996e+00 0.16459787 0.69602618 239.75 1.80619514e+00 7.35276036e-01 1.95012096e+00 0.38659969 0.80730128 240.00 1.46259542e+00 1.00859121e+00 1.77663772e+00 0.60370518 0.80963098 240.25 1.38307369e+00 1.08438133e+00 1.75749131e+00 0.66493150 0.82607102 240.50 1.24637260e+00 1.03003330e+00 1.61691474e+00 0.69064727 0.83661480 240.75 1.25820042e+00 1.03919760e+00 1.63187008e+00 0.69035889 0.87014670 241.00 1.09291432e+00 7.88540302e-01 1.34768599e+00 0.62501181 0.77036505 241.25 1.04274956e+00 5.24869992e-01 1.16739675e+00 0.46632555 0.74232919 241.50 6.90024227e-01 4.57808630e-01 8.28083435e-01 0.58578451 0.73917782 241.75 4.67444767e-01 4.41690952e-01 6.43113914e-01 0.75707794 0.68350136 242.00 1.18932384e-01 5.12376477e-01 5.25998637e-01 1.34271621 0.51777052 242.25 -2.03441613e-01 5.80831166e-01 6.15429389e-01 1.90770228 0.55350595 242.50 -6.90211306e-01 7.60274124e-01 1.02684390e+00 2.30792899 0.79307842 242.75 -8.57643376e-01 8.93272630e-01 1.23834089e+00 2.33584838 0.88025204 243.00 -1.24334291e+00 1.21332121e+00 1.73725357e+00 2.36841440 0.86999971 243.25 -1.47328391e+00 1.42271588e+00 2.04809324e+00 2.37365405 0.87037269 243.50 -1.92910586e+00 1.90754503e+00 2.71296470e+00 2.36181413 0.85108364 243.75 -2.11461553e+00 2.12128235e+00 2.99523582e+00 2.35462061 0.83847011 244.00 -2.27188388e+00 3.01938700e+00 3.77864449e+00 2.21585220 0.67403137 244.25 -2.00720998e+00 4.32371461e+00 4.76690675e+00 2.00542298 0.78378564 244.50 -1.06190477e+00 5.78453481e+00 5.88119756e+00 1.75235137 0.83852878 244.75 -1.00191394e-01 6.41360115e+00 6.41438369e+00 1.58641676 0.86029995 245.00 1.85296055e+00 6.32998835e+00 6.59562092e+00 1.28602499 0.86653484 245.25 2.61556764e+00 5.71400456e+00 6.28418986e+00 1.14151882 0.84674726 245.50 3.25265928e+00 3.20030895e+00 4.56308775e+00 0.77728574 0.80255694 245.75 2.80660690e+00 2.33540264e+00 3.65118444e+00 0.69401524 0.82869289 246.00 2.31729412e+00 2.03710780e+00 3.08539467e+00 0.72114121 0.87484416 246.25 1.98729165e+00 1.98307543e+00 2.80747507e+00 0.78433624 0.84787840 246.50 1.40106744e+00 1.80036456e+00 2.28129404e+00 0.90948192 0.74032273 246.75 1.25123075e+00 1.77713604e+00 2.17342837e+00 0.95734307 0.70423494 247.00 1.16926833e+00 1.81738334e+00 2.16103462e+00 0.99908888 0.75147623 247.25 1.17833485e+00 1.78171393e+00 2.13611272e+00 0.98648418 0.70691628 247.50 8.33114231e-01 2.02378142e+00 2.18855444e+00 1.18027697 0.76341040 247.75 8.25727217e-01 2.07673476e+00 2.23487196e+00 1.19235336 0.74248702 248.00 1.05572194e+00 2.08008902e+00 2.33266353e+00 1.10113739 0.78108506 248.25 1.01356622e+00 2.07183935e+00 2.30647670e+00 1.11581726 0.71169703 248.50 1.08647963e+00 2.41080053e+00 2.64431412e+00 1.14738393 0.64213136 248.75 1.05744225e+00 2.15702927e+00 2.40228212e+00 1.11499455 0.53263660 249.00 9.82292903e-01 1.82372280e+00 2.07144012e+00 1.07673241 0.45390666 249.25 8.35591800e-01 1.84227568e+00 2.02291704e+00 1.14498169 0.43649027 249.50 1.18114634e+00 2.35543852e+00 2.63499475e+00 1.10598542 0.45706128 249.75 1.69690453e+00 1.94133060e+00 2.57841995e+00 0.85247995 0.24327998 250.00 2.89600748e+00 2.44910089e+00 3.79275026e+00 0.70198179 0.40249062 250.25 2.23456692e+00 1.89548454e+00 2.93021347e+00 0.70348064 0.48845095 250.50 2.73277065e+00 1.39154442e+00 3.06666452e+00 0.47098561 0.60237495 250.75 2.17206655e+00 8.96849341e-01 2.34993868e+00 0.39157857 0.47646812 251.00 2.30736572e+00 9.22062570e-01 2.48478086e+00 0.38017616 0.58095464 251.25 2.26177785e+00 8.52496256e-01 2.41710341e+00 0.36044784 0.64248276 251.50 2.28797105e+00 9.62844719e-01 2.48231374e+00 0.39833253 0.68248727 251.75 2.46049146e+00 1.30659652e+00 2.78589531e+00 0.48816291 0.71108398 252.00 2.84156269e+00 1.81498205e+00 3.37174114e+00 0.56840939 0.75219821 252.25 3.08442982e+00 1.89161804e+00 3.61827668e+00 0.55012677 0.73129594 252.50 3.62282382e+00 1.44621936e+00 3.90082079e+00 0.37981370 0.74536657 252.75 4.11140002e+00 3.23909899e-01 4.12413963e+00 0.07862096 0.77314800 253.00 4.35992342e+00 -2.84434130e-01 4.36919157e+00 -0.06514601 0.81590116 253.25 3.71481225e+00 -1.38008548e+00 3.96288607e+00 -0.35570639 0.73182390 253.50 3.34343158e+00 -1.88889588e+00 3.84011229e+00 -0.51425413 0.76978262 253.75 1.87943448e+00 -1.61054222e+00 2.47510004e+00 -0.70850307 0.69595164 254.00 1.43561420e+00 -1.46544633e+00 2.05146803e+00 -0.79568098 0.68773917 254.25 7.40726722e-01 -1.21836189e+00 1.42586177e+00 -1.02453759 0.64276048 254.50 5.21214945e-01 -1.03809271e+00 1.16159437e+00 -1.10547890 0.67651008 254.75 5.81452126e-01 -4.30405577e-01 7.23419336e-01 -0.63721590 0.49745204 255.00 6.11825000e-01 -2.20224128e-01 6.50252641e-01 -0.34550802 0.49871496 255.25 5.99984658e-01 1.13118621e-02 6.00091283e-01 0.01885135 0.49337059 255.50 6.53471058e-01 1.46982880e-01 6.69797275e-01 0.22124437 0.52348044 255.75 8.05662820e-01 4.11476996e-01 9.04657890e-01 0.47219553 0.71268114 256.00 8.66613410e-01 4.69295421e-01 9.85523716e-01 0.49631553 0.77660025 256.25 1.14284790e+00 6.71438338e-01 1.32549265e+00 0.53118750 0.73957634 256.50 1.55256761e+00 6.87792779e-01 1.69809455e+00 0.41702037 0.75654486 256.75 2.32051382e+00 5.90654325e-01 2.39450557e+00 0.24924327 0.82245139 257.00 2.52018294e+00 3.01233459e-01 2.53812207e+00 0.11896400 0.79151358 257.25 2.62968567e+00 -4.78742861e-01 2.67290880e+00 -0.18008105 0.76819778 257.50 2.08552602e+00 -9.65049096e-01 2.29798576e+00 -0.43339501 0.67491647 257.75 1.36650978e+00 -1.64046989e+00 2.13506216e+00 -0.87625539 0.76986178 258.00 9.56272196e-01 -1.39486841e+00 1.69118727e+00 -0.96982449 0.70652719 258.25 6.81147924e-01 -1.36624302e+00 1.52662454e+00 -1.10830501 0.69953448 258.50 4.97193052e-01 -1.34412916e+00 1.43313787e+00 -1.21650458 0.64783856 258.75 1.40964390e-01 -1.17774207e+00 1.18614811e+00 -1.45167264 0.65161389 259.00 -3.30765468e-02 -9.04197394e-01 9.04802181e-01 -1.60736114 0.49281137 259.25 -2.55657259e-01 -7.80149698e-01 8.20971489e-01 -1.88747089 0.50746162 259.50 -2.65046867e-01 -6.93317602e-01 7.42252746e-01 -1.93594095 0.39214015 259.75 -4.27028149e-01 -7.65796908e-01 8.76811236e-01 -2.07947546 0.56114186 260.00 -6.45855441e-01 -6.84532686e-01 9.41123929e-01 -2.32713053 0.51997005 260.25 -9.09698102e-01 -5.41834476e-01 1.05883674e+00 -2.60439989 0.57312763 260.50 -1.13193397e+00 -5.13358307e-01 1.24290436e+00 -2.71581270 0.52405556 260.75 -1.49418396e+00 -5.03034491e-01 1.57658790e+00 -2.81684958 0.58740574 261.00 -2.08688857e+00 -3.30523518e-01 2.11290078e+00 -2.98451637 0.57237926 261.25 -3.03923501e+00 -2.72204761e-02 3.03935691e+00 -3.13263654 0.66357217 261.50 -2.71094373e+00 9.76631609e-01 2.88149704e+00 2.79581116 0.51651570 261.75 -2.64976829e+00 2.62550494e+00 3.73022092e+00 2.36079391 0.65362984 262.00 -1.72077613e+00 3.88910500e+00 4.25278828e+00 1.98736291 0.72473382 262.25 -5.65264656e-01 4.40127543e+00 4.43742600e+00 1.69852909 0.81275830 262.50 3.95115747e-01 3.45632667e+00 3.47883752e+00 1.45697377 0.76522984 262.75 8.95890630e-01 2.90302447e+00 3.03811967e+00 1.27146298 0.82484383 263.00 9.14881742e-01 2.35017456e+00 2.52196929e+00 1.19956321 0.82316167 263.25 9.12187346e-01 2.14414748e+00 2.33011892e+00 1.16856046 0.87669957 263.50 7.98964002e-01 2.12299041e+00 2.26835441e+00 1.21085229 0.86460902 263.75 7.31802904e-01 2.01336497e+00 2.14223575e+00 1.22217001 0.86854494 264.00 8.31861615e-01 2.09129165e+00 2.25066535e+00 1.19221032 0.91820330 264.25 8.20020170e-01 2.09672520e+00 2.25137506e+00 1.19798958 0.94888139 264.50 8.15221514e-01 2.04055731e+00 2.19737576e+00 1.19071308 0.93382048 264.75 8.74058574e-01 2.00869476e+00 2.19062389e+00 1.16037049 0.92366412 265.00 9.23772496e-01 1.95500852e+00 2.16227055e+00 1.12937679 0.90936036 265.25 8.87861152e-01 2.00252506e+00 2.19052597e+00 1.15346890 0.91691862 265.50 8.15249034e-01 2.12602293e+00 2.27697266e+00 1.20462762 0.89245572 265.75 8.40640126e-01 2.14172214e+00 2.30079324e+00 1.19676640 0.87052658 266.00 9.10686748e-01 2.15382673e+00 2.33844392e+00 1.17077135 0.88631586 266.25 1.03368574e+00 2.09711921e+00 2.33803661e+00 1.11283882 0.86689099 266.50 1.22459286e+00 2.14494726e+00 2.46990413e+00 1.05203383 0.87040611 266.75 1.26521448e+00 2.15920349e+00 2.50258414e+00 1.04076171 0.86627283 267.00 1.22754125e+00 2.14899203e+00 2.47487864e+00 1.05180955 0.86502164 267.25 1.24598425e+00 2.24873167e+00 2.57085023e+00 1.06482369 0.86850678 267.50 1.25418837e+00 2.24595174e+00 2.57240893e+00 1.06151026 0.83229493 267.75 1.22322716e+00 2.25888055e+00 2.56881802e+00 1.07448760 0.78996774 268.00 1.42171034e+00 2.45457371e+00 2.83658111e+00 1.04580488 0.84314248 268.25 1.57272665e+00 2.52005705e+00 2.97054821e+00 1.01285616 0.86033524 268.50 1.67611405e+00 2.39496419e+00 2.92321942e+00 0.96017150 0.89624707 268.75 1.65074019e+00 2.44649923e+00 2.95132201e+00 0.97722830 0.91258803 269.00 1.63847248e+00 2.28976574e+00 2.81560282e+00 0.94970134 0.92333896 269.25 1.73273863e+00 2.26481616e+00 2.85162680e+00 0.91772116 0.89160613 269.50 1.41142708e+00 2.50565659e+00 2.87583751e+00 1.05780217 0.89752952 269.75 1.37023809e+00 2.80648418e+00 3.12312438e+00 1.11660083 0.87276301 270.00 1.41266569e+00 3.32530115e+00 3.61292846e+00 1.16907528 0.84721815 270.25 1.45533809e+00 3.46896255e+00 3.76187588e+00 1.17356689 0.79818293 270.50 1.91073994e+00 3.92326494e+00 4.36382114e+00 1.11758006 0.81700217 270.75 2.50398292e+00 4.47943720e+00 5.13179190e+00 1.06107342 0.81786783 271.00 3.08365669e+00 5.11877580e+00 5.97585176e+00 1.02859877 0.84607101 271.25 4.12427076e+00 5.80152066e+00 7.11809324e+00 0.95279579 0.81769421 271.50 6.31786063e+00 7.22200458e+00 9.59545273e+00 0.85207561 0.83847882 271.75 9.48682985e+00 6.52984996e+00 1.15168955e+01 0.60283503 0.74063414 272.00 1.31069556e+01 5.56080908e+00 1.42377977e+01 0.40124706 0.77706858 272.25 1.55057721e+01 6.37530476e-01 1.55188728e+01 0.04109254 0.74260249 272.50 1.77704622e+01 -3.78259348e+00 1.81685811e+01 -0.20972835 0.80164109 272.75 1.50707197e+01 -9.57196255e+00 1.78535447e+01 -0.56585522 0.76404613 273.00 1.17837191e+01 -1.24178475e+01 1.71189652e+01 -0.81159413 0.84469063 273.25 6.20465835e+00 -1.31425151e+01 1.45335298e+01 -1.12971200 0.81596879 273.50 2.20227791e+00 -1.32164897e+01 1.33987174e+01 -1.40568228 0.83322627 273.75 -6.96204569e-01 -1.01469954e+01 1.01708514e+01 -1.63930086 0.83233361 274.00 -1.56088189e+00 -8.99819182e+00 9.13256855e+00 -1.74255336 0.88384919 274.25 -2.00999774e+00 -6.62834562e+00 6.92640286e+00 -1.86522546 0.85302028 274.50 -1.78719989e+00 -5.71118568e+00 5.98428987e+00 -1.87407266 0.87611323 274.75 -1.53023844e+00 -4.31159979e+00 4.57509808e+00 -1.91184036 0.84052348 275.00 -1.46073321e+00 -3.85035967e+00 4.11813199e+00 -1.93339777 0.85934479 275.25 -1.31153136e+00 -3.20219599e+00 3.46037189e+00 -1.95952751 0.85523638 275.50 -1.22844355e+00 -3.04210093e+00 3.28076998e+00 -1.95458647 0.86570456 275.75 -9.09689326e-01 -2.73354838e+00 2.88094106e+00 -1.89205509 0.83411791 276.00 -6.67616875e-01 -2.67507491e+00 2.75712497e+00 -1.81536969 0.82494774 276.25 -7.85008888e-01 -2.48226647e+00 2.60343730e+00 -1.87709102 0.77579699 276.50 -8.35803306e-01 -2.52017758e+00 2.65515766e+00 -1.89102626 0.79106977 276.75 -7.73430468e-01 -2.59110902e+00 2.70407852e+00 -1.86087089 0.76239164 277.00 -7.23387413e-01 -2.69984182e+00 2.79507338e+00 -1.83258430 0.75865104 277.25 -8.17003350e-01 -2.81416353e+00 2.93036019e+00 -1.85334739 0.70420142 277.50 -9.41959917e-01 -2.61576616e+00 2.78020163e+00 -1.91644805 0.58232126 277.75 -1.11593613e+00 -2.32197915e+00 2.57621827e+00 -2.01880137 0.44603478 278.00 -1.39672747e+00 -1.89892498e+00 2.35727888e+00 -2.20497596 0.33633883 278.25 -2.04126696e+00 -1.06504480e+00 2.30240988e+00 -2.66069153 0.22736459 278.50 -1.96015239e+00 -1.15978893e-01 1.96358053e+00 -3.08249325 0.19812038 278.75 -1.96062126e+00 9.91715514e-01 2.19716531e+00 2.67330230 0.35295739 279.00 -1.13840955e+00 1.05124205e+00 1.54954385e+00 2.39598232 0.28498040 279.25 -8.21181613e-01 1.07589594e+00 1.35347379e+00 2.22272602 0.38505017 279.50 -5.15505748e-01 8.16222344e-01 9.65383391e-01 2.13410987 0.31586132 279.75 -4.85828248e-01 4.91281767e-01 6.90931878e-01 2.35061327 0.24023346 280.00 -4.89856390e-01 3.77021804e-01 6.18146199e-01 2.48562878 0.26205826 280.25 -5.88162246e-01 4.73063841e-01 7.54800785e-01 2.46423015 0.53066377 280.50 -5.87839967e-01 5.76556091e-01 8.23391009e-01 2.36588494 0.59637036 280.75 -6.51450981e-01 7.44723872e-01 9.89445313e-01 2.28948759 0.75567943 281.00 -5.58977523e-01 7.22800985e-01 9.13727057e-01 2.22907419 0.71418925 281.25 -5.38796753e-01 6.88154012e-01 8.73989637e-01 2.23506004 0.78167062 281.50 -4.45274225e-01 6.35721703e-01 7.76151544e-01 2.18180626 0.69957134 281.75 -3.39610218e-01 6.29233185e-01 7.15031119e-01 2.06571337 0.76533968 282.00 -3.67982339e-01 6.09646560e-01 7.12095450e-01 2.11385829 0.72180857 282.25 -3.65999717e-01 5.95996437e-01 6.99405137e-01 2.12151695 0.74162416 282.50 -2.54233826e-01 6.74811088e-01 7.21113613e-01 1.93109874 0.75964602 282.75 -2.10498892e-01 7.45117025e-01 7.74279771e-01 1.84612591 0.81759824 283.00 -1.63026629e-01 8.24511910e-01 8.40474611e-01 1.76600345 0.80261574 283.25 -8.24177548e-02 8.66328717e-01 8.70240273e-01 1.66564537 0.82262076 283.50 -2.12216302e-02 8.55156402e-01 8.55419680e-01 1.59560732 0.80408121 283.75 4.97057415e-02 8.81494011e-01 8.82894304e-01 1.51446791 0.77921940 284.00 3.52970200e-01 9.62408407e-01 1.02509410e+00 1.21927174 0.80771401 284.25 4.89171131e-01 8.79513926e-01 1.00639612e+00 1.06321811 0.83256121 284.50 7.17366243e-01 7.69189707e-01 1.05179234e+00 0.82024548 0.83508297 284.75 8.28621919e-01 6.95421158e-01 1.08176932e+00 0.69822008 0.88758296 285.00 9.05554463e-01 4.84263324e-01 1.02690791e+00 0.49107514 0.85902904 285.25 8.83219953e-01 3.47220875e-01 9.49020453e-01 0.37457057 0.82044578 285.50 8.41859141e-01 2.17526245e-01 8.69508183e-01 0.25285748 0.89986064 285.75 8.06859144e-01 1.83526977e-01 8.27468325e-01 0.22365325 0.92444388 286.00 7.66843547e-01 9.55831839e-02 7.72777569e-01 0.12400540 0.94975630 286.25 7.60368176e-01 8.82051049e-02 7.65467115e-01 0.11548697 0.95211527 286.50 6.80832259e-01 2.75687789e-02 6.81390198e-01 0.04047065 0.93955077 286.75 6.51510306e-01 -1.03277361e-02 6.51592159e-01 -0.01585066 0.94112101 287.00 5.88908821e-01 -2.52471684e-02 5.89449759e-01 -0.04284486 0.93879793 287.25 5.76869162e-01 -3.36711619e-02 5.77850999e-01 -0.05830265 0.94614203 287.50 5.68824177e-01 -2.00916167e-02 5.69178898e-01 -0.03530663 0.96514439 287.75 5.56237502e-01 -2.43359885e-02 5.56769610e-01 -0.04372319 0.95739773 288.00 5.05208168e-01 -6.23827417e-02 5.09045086e-01 -0.12285739 0.95831640 288.25 4.85865054e-01 -7.21867118e-02 4.91198302e-01 -0.14749463 0.95271806 288.50 4.72230352e-01 -6.94102291e-02 4.77304185e-01 -0.14593886 0.94936110 288.75 4.71394297e-01 -6.51206542e-02 4.75871077e-01 -0.13727591 0.94428348 289.00 4.60315302e-01 -7.43494669e-02 4.66281053e-01 -0.16013557 0.95178149 289.25 4.31647238e-01 -7.76717898e-02 4.38579805e-01 -0.17803748 0.92958592 289.50 4.06788447e-01 -7.14639440e-02 4.13018082e-01 -0.17390383 0.91730554 289.75 4.12441270e-01 -7.89377752e-02 4.19927344e-01 -0.18910467 0.92781631 290.00 4.17703474e-01 -7.28686053e-02 4.24011823e-01 -0.17271250 0.94157810 290.25 4.07843337e-01 -6.62888271e-02 4.13195348e-01 -0.16112603 0.92645970 290.50 3.99172355e-01 -7.20742634e-02 4.05627007e-01 -0.17863459 0.94168218 290.75 4.02141285e-01 -6.13895028e-02 4.06800054e-01 -0.15148703 0.91374075 291.00 3.96199329e-01 -3.53519108e-02 3.97773385e-01 -0.08899192 0.92824829 291.25 3.98858032e-01 -4.15671719e-02 4.01018153e-01 -0.10384061 0.91040900 291.50 3.94238178e-01 -4.45150091e-02 3.96743402e-01 -0.11243777 0.90618937 291.75 3.96583323e-01 -4.77536432e-02 3.99448048e-01 -0.11983568 0.92106839 292.00 4.05429075e-01 -3.60519173e-02 4.07028838e-01 -0.08868960 0.94812817 292.25 4.04282103e-01 -4.46825684e-02 4.06743840e-01 -0.11007648 0.90842041 292.50 3.96570054e-01 -5.40387277e-02 4.00234921e-01 -0.13543115 0.89485483 292.75 3.90501770e-01 -3.35676618e-02 3.91941858e-01 -0.08574954 0.89339294 293.00 3.78215630e-01 -3.91903699e-02 3.80240645e-01 -0.10325064 0.92967467 293.25 3.95137825e-01 -5.61126150e-02 3.99102150e-01 -0.14106450 0.90381776 293.50 4.13323677e-01 -6.48855817e-02 4.18385708e-01 -0.15571406 0.91493776 293.75 4.03879479e-01 -7.31915005e-02 4.10457829e-01 -0.17927550 0.89936271 294.00 4.13196534e-01 -7.82811872e-02 4.20546454e-01 -0.18723364 0.87618629 294.25 4.21594042e-01 -6.46308506e-02 4.26519265e-01 -0.15211688 0.85740397 294.50 4.21151120e-01 -5.82967134e-02 4.25166758e-01 -0.13754825 0.89114230 294.75 4.20040452e-01 -7.41514976e-02 4.26535375e-01 -0.17473387 0.87711494 295.00 4.25899187e-01 -8.79258999e-02 4.34880537e-01 -0.20358750 0.87680910 295.25 4.35683225e-01 -1.45166028e-01 4.59230931e-01 -0.32162307 0.84076985 295.50 4.31186130e-01 -1.65440409e-01 4.61835477e-01 -0.36636463 0.84600559 295.75 4.04308082e-01 -1.77023629e-01 4.41364238e-01 -0.41269864 0.78035243 296.00 3.79435847e-01 -1.71385787e-01 4.16346790e-01 -0.42425496 0.72199875 296.25 2.92133656e-01 -2.68058769e-01 3.96481495e-01 -0.74244849 0.63848780 296.50 2.61164321e-01 -2.67000909e-01 3.73492019e-01 -0.79644840 0.67006412 296.75 3.04616753e-01 -2.12853162e-01 3.71615170e-01 -0.60989141 0.73426055 297.00 3.10291050e-01 -1.90401789e-01 3.64051338e-01 -0.55037639 0.67589813 297.25 2.69743611e-01 -1.48537033e-01 3.07936464e-01 -0.50334983 0.51562319 297.50 3.05804176e-01 -1.53507650e-01 3.42170707e-01 -0.46523054 0.51144994 297.75 2.79870756e-01 -1.46835832e-01 3.16051264e-01 -0.48317718 0.48698824 298.00 2.45659590e-01 -1.74878190e-01 3.01547700e-01 -0.61864941 0.45855769 298.25 2.34191210e-01 -2.53016685e-01 3.44765088e-01 -0.82401846 0.51603950 298.50 1.87144624e-01 -2.33295279e-01 2.99081590e-01 -0.89472800 0.39175230 298.75 1.91923318e-01 -3.06890640e-01 3.61961911e-01 -1.01192368 0.29301835 299.00 1.75607194e-01 -3.17591664e-01 3.62908186e-01 -1.06570340 0.29402329 299.25 1.12035714e-01 -3.54389903e-01 3.71677555e-01 -1.26460160 0.18255317 299.50 1.06003626e-01 -2.25043094e-01 2.48759247e-01 -1.13058640 0.08465408 299.75 1.19195886e-01 1.97027289e-02 1.20813314e-01 0.16381579 0.03964683 300.00 1.65981915e-01 9.09639062e-02 1.89273423e-01 0.50133336 0.08840752 300.25 3.57864353e-01 8.92964492e-02 3.68837025e-01 0.24453247 0.13215669 300.50 2.96401095e-01 -2.89209556e-02 2.97808715e-01 -0.09726582 0.10969384 300.75 2.08603301e-01 -8.88563118e-02 2.26739457e-01 -0.40268207 0.12340471 301.00 2.69104085e-01 -4.06527814e-02 2.72157412e-01 -0.14993343 0.25846896 301.25 2.61913107e-01 -6.43532907e-02 2.69703211e-01 -0.24093199 0.25404358 301.50 2.23811521e-01 -2.52151628e-02 2.25227444e-01 -0.11218942 0.16045662 301.75 2.68690239e-01 6.44850761e-02 2.76320049e-01 0.23554294 0.17227450 302.00 3.48836051e-01 9.03466141e-02 3.60345808e-01 0.25342598 0.20661979 302.25 3.94971248e-01 1.46676739e-01 4.21326895e-01 0.35557611 0.27334794 302.50 3.55050715e-01 1.02790327e-01 3.69630710e-01 0.28180432 0.28189242 302.75 3.74150506e-01 1.50242423e-02 3.74452039e-01 0.04013405 0.30620464 303.00 4.60898856e-01 -1.46320697e-01 4.83567474e-01 -0.30740457 0.32086691 303.25 4.28178014e-01 -2.18907718e-01 4.80891880e-01 -0.47261021 0.37367023 303.50 3.48723218e-01 -1.16210600e-01 3.67576912e-01 -0.32167191 0.33177383 303.75 3.55568946e-01 -7.55516538e-02 3.63506984e-01 -0.20936724 0.41758669 304.00 2.91979756e-01 -5.94681432e-02 2.97974223e-01 -0.20092396 0.28556083 304.25 2.95624609e-01 -6.75612383e-02 3.03246484e-01 -0.22467870 0.33223545 304.50 3.11117271e-01 -1.62740253e-01 3.51110162e-01 -0.48194327 0.38239508 304.75 3.77596852e-01 -1.76049203e-01 4.16620576e-01 -0.43627336 0.48567637 305.00 3.95363305e-01 -1.25584069e-01 4.14829484e-01 -0.30756269 0.35428932 305.25 4.23042780e-01 -1.05351535e-01 4.35963461e-01 -0.24406817 0.37726414 305.50 3.75054528e-01 -1.16991363e-01 3.92877689e-01 -0.30236696 0.27846164 305.75 3.16945520e-01 -1.33220715e-01 3.43805499e-01 -0.39790581 0.20206299 306.00 4.37582536e-01 -2.05427074e-01 4.83403308e-01 -0.43891771 0.28530495 306.25 4.57927330e-01 -1.92858912e-01 4.96882279e-01 -0.39861037 0.36715578 306.50 4.59810320e-01 -1.07408965e-01 4.72188750e-01 -0.22947920 0.38449927 306.75 4.52691902e-01 -6.29133395e-02 4.57042719e-01 -0.13809155 0.41590716 307.00 3.86975913e-01 -1.42770621e-01 4.12472796e-01 -0.35344662 0.47556222 307.25 4.04461990e-01 -1.83920496e-01 4.44315485e-01 -0.42677939 0.47314765 307.50 4.56511975e-01 -2.15264999e-01 5.04719925e-01 -0.44062391 0.43809433 307.75 4.25403161e-01 -2.37971912e-01 4.87440745e-01 -0.51003392 0.48433367 308.00 4.09501195e-01 -2.18816975e-01 4.64297423e-01 -0.49074854 0.54006833 308.25 4.00818431e-01 -2.28600294e-01 4.61425518e-01 -0.51832043 0.57185499 308.50 4.45554186e-01 -3.20484638e-01 5.48843271e-01 -0.62355821 0.64263064 308.75 4.46463762e-01 -3.80122161e-01 5.86364007e-01 -0.70531006 0.64164236 309.00 3.86384687e-01 -3.81522945e-01 5.43003576e-01 -0.77906709 0.52125366 309.25 4.09360280e-01 -3.45847669e-01 5.35897797e-01 -0.70149610 0.47644788 309.50 3.56393212e-01 -2.73734325e-01 4.49384693e-01 -0.65496489 0.54286324 309.75 3.62648761e-01 -2.96828489e-01 4.68637680e-01 -0.68592086 0.62290188 310.00 3.40418395e-01 -3.13057669e-01 4.62482203e-01 -0.74355309 0.64254950 310.25 3.57776389e-01 -3.18686243e-01 4.79129279e-01 -0.72767624 0.54069905 310.50 3.85068023e-01 -2.39406427e-01 4.53423444e-01 -0.55624081 0.52955643 310.75 4.32372386e-01 -2.72552107e-01 5.11107162e-01 -0.56244748 0.59722710 311.00 5.09478444e-01 -3.79167699e-01 6.35087733e-01 -0.63979625 0.74837400 311.25 4.57765639e-01 -4.45104945e-01 6.38488678e-01 -0.77137637 0.71760832 311.50 4.35707440e-01 -4.48152495e-01 6.25045304e-01 -0.79947758 0.72798527 311.75 4.30939257e-01 -4.96733869e-01 6.57611724e-01 -0.85620395 0.71866412 312.00 3.92650793e-01 -5.11497748e-01 6.44829118e-01 -0.91609514 0.65617993 312.25 3.91319123e-01 -5.21565997e-01 6.52044281e-01 -0.92711778 0.53288518 312.50 5.24727469e-01 -5.89577699e-01 7.89265975e-01 -0.84353050 0.58018108 312.75 4.98071609e-01 -6.04762372e-01 7.83462095e-01 -0.88184040 0.52237322 313.00 4.30251775e-01 -6.30218320e-01 7.63080415e-01 -0.97177384 0.42948637 313.25 3.26929346e-01 -5.20215507e-01 6.14415959e-01 -1.00972008 0.25325906 313.50 1.53268093e-01 -6.04424521e-01 6.23554416e-01 -1.32245402 0.16425125 313.75 -2.29771249e-02 -4.18198781e-01 4.18829522e-01 -1.62568421 0.04038462 314.00 -5.31019243e-01 -1.02449221e-01 5.40811685e-01 -2.95100490 0.07888973 314.25 -7.70445575e-01 -8.63240801e-02 7.75266555e-01 -3.03001366 0.43540099 314.50 -7.84028755e-01 -3.33062394e-02 7.84735875e-01 -3.09913729 0.56483048 314.75 -7.34577243e-01 -9.69207334e-02 7.40943557e-01 -3.01040955 0.56743249 315.00 -7.54175974e-01 -1.40020630e-01 7.67063998e-01 -2.95802240 0.64050497 315.25 -7.27099683e-01 -1.26779543e-01 7.38069781e-01 -2.96896478 0.54079923 315.50 -7.11458407e-01 2.38458424e-02 7.11857913e-01 3.10808835 0.53947147 315.75 -5.52426433e-01 8.95400854e-03 5.52498994e-01 3.12538556 0.55931991 316.00 -5.23211648e-01 2.42105429e-02 5.23771495e-01 3.09535269 0.60804129 316.25 -5.66136730e-01 6.06076598e-03 5.66169171e-01 3.13088758 0.72421131 316.50 -5.81783676e-01 1.67940955e-02 5.82026020e-01 3.11273410 0.77624104 316.75 -6.53294802e-01 1.21115016e-01 6.64426780e-01 2.95828280 0.82884314 317.00 -6.65818231e-01 1.45241176e-01 6.81475543e-01 2.92681776 0.82631685 317.25 -6.69554916e-01 2.47320790e-01 7.13772624e-01 2.78775741 0.79592480 317.50 -6.63816666e-01 2.89581507e-01 7.24230637e-01 2.73024265 0.79560677 317.75 -5.89357561e-01 4.58921135e-01 7.46961139e-01 2.47998738 0.76356179 318.00 -5.45770169e-01 5.28806086e-01 7.59934835e-01 2.37197994 0.71818095 318.25 -4.56565552e-01 5.95777793e-01 7.50601946e-01 2.22467032 0.53754364 318.50 -4.37984179e-01 6.07875658e-01 7.49228241e-01 2.19515917 0.45488589 318.75 -3.94046022e-01 6.74187341e-01 7.80897457e-01 2.09972258 0.37051988 319.00 -2.57654811e-01 8.75211506e-01 9.12349266e-01 1.85709978 0.37251693 319.25 2.98687710e-01 1.02141126e+00 1.06418763e+00 1.28630211 0.47172874 319.50 4.41768687e-01 8.49182301e-01 9.57220013e-01 1.09109732 0.49282967 319.75 4.16254697e-01 5.83864331e-01 7.17053366e-01 0.95144478 0.54037061 320.00 3.62974248e-01 5.23516979e-01 6.37040291e-01 0.96455547 0.52397442 320.25 3.54495575e-01 3.55643685e-01 5.02144942e-01 0.78701490 0.39701757 320.50 4.25323252e-01 3.46847020e-01 5.48819391e-01 0.68411518 0.38891729 320.75 6.25985809e-01 3.52014114e-01 7.18172799e-01 0.51226458 0.56661234 321.00 6.58160602e-01 2.71433401e-01 7.11935017e-01 0.39116047 0.42484421 321.25 8.78129259e-01 1.18190628e-01 8.86047414e-01 0.13378964 0.45580453 321.50 8.11111633e-01 3.59786591e-02 8.11909197e-01 0.04432816 0.43709889 321.75 5.64327005e-01 -2.42812083e-01 6.14347357e-01 -0.40632456 0.38595636 322.00 3.91406148e-01 -3.05685902e-01 4.96631295e-01 -0.66304408 0.36216982 322.25 2.94183683e-01 -1.51611792e-01 3.30953433e-01 -0.47586343 0.44190669 322.50 1.83529322e-01 -1.58083611e-01 2.42226011e-01 -0.71104850 0.34803298 322.75 1.63900865e-01 -1.97364266e-01 2.56546578e-01 -0.87776297 0.42963270 323.00 1.53588363e-01 -1.38922337e-01 2.07096115e-01 -0.73530169 0.35171271 323.25 9.03754813e-02 -9.08852181e-02 1.28171177e-01 -0.78821033 0.18601131 323.50 7.34120421e-02 -5.09657828e-02 8.93691163e-02 -0.60685162 0.10588725 323.75 6.01119888e-02 -4.86647623e-02 7.73415172e-02 -0.68054812 0.08526375 324.00 4.82129237e-02 -4.84017525e-02 6.83170231e-02 -0.78735261 0.06501336 324.25 5.77637369e-02 -4.31999641e-02 7.21310349e-02 -0.64213872 0.10919254 324.50 8.91017163e-02 -1.68885421e-02 9.06881398e-02 -0.18732013 0.16521382 324.75 7.80426555e-02 3.76784174e-03 7.81335569e-02 0.04824180 0.16464051 325.00 7.41532730e-02 1.88855958e-02 7.65204131e-02 0.24938154 0.13434341 325.25 8.11488623e-02 1.61274835e-02 8.27359267e-02 0.19618324 0.18160796 325.50 1.34025933e-01 1.65337020e-02 1.35041898e-01 0.12274183 0.32120497 325.75 1.61760366e-01 4.01598003e-02 1.66671010e-01 0.24334717 0.40636174 326.00 1.95195276e-01 1.81680060e-02 1.96038955e-01 0.09280867 0.44098903 326.25 2.01524748e-01 -1.67954720e-02 2.02223421e-01 -0.08314982 0.50701566 326.50 2.77414401e-01 -3.92845034e-02 2.80182123e-01 -0.14067411 0.56510750 326.75 2.70563881e-01 -6.79215593e-02 2.78959051e-01 -0.24595447 0.60037411 327.00 1.79431499e-01 -5.68997182e-02 1.88237193e-01 -0.30708019 0.47065072 327.25 1.58999616e-01 -8.11533043e-02 1.78512567e-01 -0.47193245 0.48759904 327.50 1.36873905e-01 -7.02737902e-02 1.53859909e-01 -0.47432582 0.32011081 327.75 1.32597662e-01 -9.43567233e-02 1.62743145e-01 -0.61846998 0.29089822 328.00 1.00718657e-01 -1.46174032e-01 1.77513649e-01 -0.96746910 0.28216668 328.25 1.21609879e-01 -1.58930169e-01 2.00119367e-01 -0.91765181 0.30452413 328.50 5.60988843e-02 -1.23950893e-01 1.36054800e-01 -1.14579098 0.14281050 328.75 -5.08515487e-03 -1.63342934e-01 1.63422070e-01 -1.60191805 0.21995630 329.00 -4.08031231e-02 -1.18925842e-01 1.25730866e-01 -1.90130847 0.14707037 329.25 -7.62833333e-02 -5.94881201e-02 9.67366702e-02 -2.47927134 0.07532130 329.50 -2.13806838e-01 2.42984189e-02 2.15183124e-01 3.02843157 0.32863464 329.75 -1.97290175e-01 6.52716108e-02 2.07807113e-01 2.82208718 0.26170841 330.00 -1.69139690e-02 2.12376429e-01 2.13048891e-01 1.65027004 0.27178889 330.25 5.90712372e-02 1.84217126e-01 1.93456353e-01 1.26049395 0.20144408 330.50 1.46141304e-01 3.09222043e-02 1.49376917e-01 0.20851564 0.12951002 330.75 1.55978493e-01 -4.95882250e-02 1.63671263e-01 -0.30781235 0.11453035 331.00 -8.07744958e-03 -1.56942731e-01 1.57150457e-01 -1.62221845 0.09815750 331.25 -9.59407189e-02 -1.05710799e-01 1.42756417e-01 -2.30778203 0.10071939 331.50 -2.48770751e-01 -7.62898290e-02 2.60205735e-01 -2.84403044 0.38526290 331.75 -3.47289471e-01 -7.11864282e-03 3.47362422e-01 -3.12109780 0.49810532 332.00 -5.00114639e-01 7.67531481e-02 5.05970056e-01 2.98930972 0.68900752 332.25 -6.00054519e-01 1.62315619e-01 6.21620290e-01 2.87741350 0.71321408 332.50 -6.04752611e-01 2.84276648e-01 6.68235686e-01 2.70217364 0.76143079 332.75 -6.24058503e-01 4.92149863e-01 7.94770724e-01 2.47382457 0.68496645 333.00 -7.02846457e-01 7.60192840e-01 1.03531942e+00 2.31701780 0.72210854 333.25 -6.94271016e-01 9.42866917e-01 1.17090148e+00 2.20549783 0.69985696 333.50 -6.34715840e-01 1.18897430e+00 1.34778488e+00 2.06114398 0.68787540 333.75 -5.19627131e-01 1.32408868e+00 1.42240050e+00 1.94476968 0.54943470 334.00 -2.38524803e-01 1.76643554e+00 1.78246699e+00 1.70501619 0.42837434 334.25 9.11531005e-01 1.04958680e+00 1.39015151e+00 0.85567870 0.31102159 334.50 1.44005404e+00 8.70641053e-01 1.68278682e+00 0.54378705 0.54598334 334.75 9.35912107e-01 8.70015137e-01 1.27783325e+00 0.74892507 0.48701410 335.00 8.02754372e-01 1.07520800e+00 1.34182220e+00 0.92947234 0.56067065 335.25 5.19387764e-01 1.40364777e+00 1.49665985e+00 1.21639254 0.56247382 335.50 2.63227722e-01 1.64136683e+00 1.66233988e+00 1.41177930 0.57329899 335.75 -6.68625755e-01 1.29465899e+00 1.45712124e+00 2.04751663 0.21181623 336.00 -8.54272685e-01 8.87392030e-01 1.23176558e+00 2.33718087 0.09979314 336.25 4.01727713e-02 1.37979132e-01 1.43708359e-01 1.28747746 0.00104140 336.50 -5.64892092e-01 -2.20609447e-01 6.06441757e-01 -2.76927335 0.01529572 336.75 -1.48739946e+00 2.13492812e-01 1.50264311e+00 2.99903207 0.10994233 337.00 -1.98466958e+00 -2.50723919e-01 2.00044391e+00 -3.01592803 0.19674027 337.25 -2.61097888e+00 -1.03992848e+00 2.81045582e+00 -2.76256072 0.56976513 337.50 -2.60427844e+00 -9.97086598e-01 2.78862831e+00 -2.77594469 0.69140813 337.75 -2.09686014e+00 -1.02408379e+00 2.33357452e+00 -2.68727678 0.72675395 338.00 -1.92025235e+00 -8.57941815e-01 2.10319596e+00 -2.72141473 0.78147662 338.25 -1.91514293e+00 -6.63430052e-01 2.02679843e+00 -2.80811711 0.80204501 338.50 -1.87006660e+00 -5.83029234e-01 1.95884460e+00 -2.83937367 0.82058703 338.75 -1.60596739e+00 -2.52095588e-01 1.62563324e+00 -2.98588896 0.82654930 339.00 -1.41918738e+00 -1.64854051e-01 1.42873009e+00 -3.02595005 0.82268251 339.25 -1.14371714e+00 -1.96602497e-02 1.14388611e+00 -3.12440456 0.79989854 339.50 -1.03819633e+00 -2.04556605e-02 1.03839783e+00 -3.12189213 0.77213325 339.75 -8.98755660e-01 -4.47957321e-02 8.99871321e-01 -3.09179192 0.78859836 340.00 -8.40721757e-01 -6.79684617e-02 8.43464750e-01 -3.06092273 0.80692856 340.25 -8.07252189e-01 9.98004417e-03 8.07313878e-01 3.12923030 0.81454742 340.50 -7.75015603e-01 -1.84709643e-02 7.75235682e-01 -3.11776414 0.80375522 340.75 -7.68393720e-01 1.37842562e-02 7.68517348e-01 3.12365552 0.83592752 341.00 -7.35722327e-01 7.88518692e-03 7.35764581e-01 3.13087545 0.80576891 341.25 -7.36367599e-01 3.05651867e-02 7.37001677e-01 3.10010841 0.84962716 341.50 -7.14039692e-01 3.94660982e-02 7.15129537e-01 3.08637726 0.80815558 341.75 -6.82138163e-01 7.17817414e-02 6.85904579e-01 3.03674801 0.81936724 342.00 -6.90754633e-01 1.26526674e-01 7.02247081e-01 2.96042930 0.78900799 342.25 -6.40860118e-01 2.13706621e-01 6.75553263e-01 2.81972051 0.81703847 342.50 -5.62847785e-01 2.09923930e-01 6.00720971e-01 2.78460509 0.72353092 342.75 -5.21651861e-01 2.59044497e-01 5.82430009e-01 2.68068076 0.73783195 343.00 -4.68312656e-01 2.92914373e-01 5.52372676e-01 2.58265719 0.66286265 343.25 -4.14082849e-01 3.10438954e-01 5.17529661e-01 2.49828196 0.67518885 343.50 -3.83173967e-01 3.05665704e-01 4.90156926e-01 2.46824324 0.55171514 343.75 -3.90313565e-01 3.26234980e-01 5.08698281e-01 2.44538396 0.62684919 344.00 -3.24389568e-01 3.81005846e-01 5.00393891e-01 2.27610441 0.54642715 344.25 -3.35867995e-01 4.43180681e-01 5.56072321e-01 2.21930757 0.63101328 344.50 -3.49101442e-01 5.64873521e-01 6.64043606e-01 2.12435840 0.67865619 344.75 -3.33149586e-01 6.92527058e-01 7.68493574e-01 2.01918041 0.77611486 345.00 -1.99645963e-01 8.48351027e-01 8.71526233e-01 1.80192492 0.77606997 345.25 -1.05072057e-01 9.41614096e-01 9.47458307e-01 1.68192378 0.81861222 345.50 3.44241396e-02 1.05901652e+00 1.05957586e+00 1.53830201 0.80667372 345.75 1.44170491e-01 1.17900237e+00 1.18778438e+00 1.44911864 0.86196221 346.00 4.62347239e-01 1.29868372e+00 1.37852979e+00 1.22877551 0.89481708 346.25 6.81432110e-01 1.34297958e+00 1.50596941e+00 1.10124373 0.92605952 346.50 1.07133517e+00 1.23843300e+00 1.63752110e+00 0.85761634 0.91876076 346.75 1.26771337e+00 1.15857580e+00 1.71738029e+00 0.74044720 0.93879474 347.00 1.42598430e+00 1.04590506e+00 1.76843112e+00 0.63283239 0.91536613 347.25 1.57897658e+00 1.02605050e+00 1.88306841e+00 0.57624864 0.91414158 347.50 1.76087241e+00 1.03995732e+00 2.04503860e+00 0.53347320 0.91273380 347.75 1.86044191e+00 1.03586140e+00 2.12937853e+00 0.50803555 0.89924543 348.00 2.40103869e+00 1.14070924e+00 2.65823332e+00 0.44352169 0.90257389 348.25 2.60315239e+00 1.12921507e+00 2.83752164e+00 0.40929017 0.92022511 348.50 3.10784402e+00 1.30081086e+00 3.36909533e+00 0.39640101 0.90596819 348.75 3.50250796e+00 1.20143404e+00 3.70283753e+00 0.33044403 0.90375799 349.00 4.10223494e+00 7.22040835e-01 4.16529404e+00 0.17422701 0.89678772 349.25 4.53255478e+00 5.27612521e-01 4.56315985e+00 0.11588357 0.87950720 349.50 5.27241276e+00 -3.12587475e-01 5.28167088e+00 -0.05921805 0.85675360 349.75 5.45112124e+00 -7.31096163e-01 5.49992948e+00 -0.13332290 0.83645814 350.00 5.97096039e+00 -1.73478638e+00 6.21786554e+00 -0.28275292 0.88149612 350.25 5.98020235e+00 -1.98080573e+00 6.29971519e+00 -0.31985385 0.87344127 350.50 5.71433438e+00 -2.68114442e+00 6.31206407e+00 -0.43870238 0.86733953 350.75 5.74873092e+00 -2.72529572e+00 6.36200786e+00 -0.44268854 0.83462619 351.00 6.97336333e+00 -3.15433312e+00 7.65360134e+00 -0.42479840 0.82372145 351.25 7.13358097e+00 -3.39830900e+00 7.90167587e+00 -0.44457526 0.81677937 351.50 6.78244656e+00 -4.34648578e+00 8.05565143e+00 -0.56991125 0.79899850 351.75 5.67156307e+00 -5.10104264e+00 7.62805766e+00 -0.73248729 0.63907117 352.00 4.48825932e+00 -6.28382048e+00 7.72210280e+00 -0.95056622 0.64515492 352.25 2.66259413e+00 -5.12170917e+00 5.77246155e+00 -1.09138380 0.46371511 352.50 1.21784547e+00 -4.79124711e+00 4.94360157e+00 -1.32188620 0.46569091 352.75 1.61913766e+00 -3.36851043e+00 3.73744155e+00 -1.12273298 0.35992952 353.00 1.90030773e+00 -1.92340634e+00 2.70382348e+00 -0.79143897 0.25487401 353.25 3.35939049e+00 4.29838909e-04 3.35939052e+00 0.00012795 0.22878614 353.50 5.38813134e+00 1.73578464e+00 5.66082217e+00 0.31165170 0.38486847 353.75 8.05607843e+00 6.32693660e-01 8.08088491e+00 0.07837531 0.31183989 354.00 1.57729869e+01 -2.92576161e+00 1.60420447e+01 -0.18340736 0.57956366 354.25 1.72148417e+01 -7.51233281e+00 1.87825962e+01 -0.41147585 0.58115783 354.50 2.04666016e+01 -1.34326204e+01 2.44809532e+01 -0.58080461 0.73637344 354.75 1.44864166e+01 -1.72705398e+01 2.25416905e+01 -0.87284430 0.57475189 355.00 8.95419284e+00 -2.53856751e+01 2.69185823e+01 -1.23169489 0.61934504 355.25 -4.58258611e+00 -2.71915173e+01 2.75749653e+01 -1.73775742 0.53627943 355.50 -1.42980180e+01 -2.63000272e+01 2.99353428e+01 -2.06875147 0.51359685 355.75 -1.89049935e+01 -7.40737466e+00 2.03043833e+01 -2.76815691 0.48906961 356.00 -1.85643502e+01 -2.41181732e+00 1.87203622e+01 -3.01239966 0.66400226 356.25 -1.23474312e+01 1.79534994e+00 1.24772729e+01 2.99720184 0.72172723 356.50 -8.84213913e+00 2.62473628e+00 9.22348442e+00 2.85303375 0.74008852 356.75 -4.48197546e+00 2.05305695e+00 4.92982219e+00 2.71204830 0.62607150 357.00 -2.88923092e+00 1.35218837e+00 3.18999510e+00 2.70386313 0.62231581 357.25 -1.08620679e+00 2.64575421e-01 1.11796482e+00 2.90266787 0.32338402 357.50 -5.00296336e-01 -1.61643711e-01 5.25761460e-01 -2.82908388 0.17150544 357.75 1.17143453e-01 -7.87561512e-01 7.96225925e-01 -1.42313695 0.28328614 358.00 5.81455708e-01 -1.21900458e+00 1.35057873e+00 -1.12572377 0.43217574 358.25 3.16722372e-01 -3.03924155e+00 3.05569996e+00 -1.46696014 0.75368107 358.50 2.60176288e-01 -3.37285429e+00 3.38287418e+00 -1.49381047 0.89378689 358.75 -5.28153453e-01 -3.13120846e+00 3.17543894e+00 -1.73789745 0.94066573 359.00 -6.92582869e-01 -3.12539505e+00 3.20121309e+00 -1.78887083 0.96478633 359.25 -1.09966498e+00 -2.91797082e+00 3.11830351e+00 -1.93119623 0.97037333 359.50 -1.24670512e+00 -2.69723969e+00 2.97142652e+00 -2.00376184 0.97156851 359.75 -1.43681364e+00 -2.17145219e+00 2.60377381e+00 -2.15534096 0.96455147 360.00 -1.41653538e+00 -1.88016589e+00 2.35405953e+00 -2.21647613 0.96858313 360.25 -1.37367573e+00 -1.61574756e+00 2.12076052e+00 -2.27539469 0.97487845 360.50 -1.37508889e+00 -1.47296845e+00 2.01506961e+00 -2.32184088 0.96659600 360.75 -1.42846852e+00 -1.00677489e+00 1.74760350e+00 -2.52765702 0.94034515 361.00 -1.41530676e+00 -6.68419920e-01 1.56520875e+00 -2.70036660 0.88301074 361.25 -1.13364827e+00 -1.49353383e-02 1.13374665e+00 -3.12841884 0.69038248 361.50 -5.16107243e-01 8.85614918e-02 5.23650479e-01 2.97165258 0.24905352 361.75 1.78559099e-01 -2.67256508e-01 3.21417786e-01 -0.98178907 0.21959026 362.00 1.33208097e-01 -4.16498523e-01 4.37281850e-01 -1.26124896 0.43959707 362.25 2.58408408e-01 -5.08078338e-01 5.70016231e-01 -1.10029278 0.68535280 362.50 3.23563866e-01 -6.30366339e-01 7.08558606e-01 -1.09656941 0.81190073 362.75 3.35148752e-01 -7.95797787e-01 8.63492214e-01 -1.17219276 0.91422373 363.00 2.40040895e-01 -8.50436848e-01 8.83664226e-01 -1.29569687 0.89871813 363.25 1.45985886e-01 -9.05677813e-01 9.17368072e-01 -1.41098133 0.93449703 363.50 6.50676414e-02 -8.47615289e-01 8.50109097e-01 -1.49418105 0.91285820 363.75 1.60832656e-02 -7.75148161e-01 7.75314996e-01 -1.55005067 0.92579748 364.00 9.33562372e-03 -6.64598042e-01 6.64663607e-01 -1.55675023 0.84666306 364.25 6.09946177e-02 -5.14865836e-01 5.18466173e-01 -1.45287890 0.86127532 364.50 1.04680927e-01 -4.98629044e-01 5.09498793e-01 -1.36386401 0.80740043 364.75 2.57410583e-01 -5.01365409e-01 5.63584494e-01 -1.09647115 0.80185604 365.00 3.81188017e-01 -6.02808788e-01 7.13219979e-01 -1.00692684 0.87281987 365.25 3.85992254e-01 -6.67393091e-01 7.70975718e-01 -1.04644195 0.94580926 365.50 3.78718034e-01 -6.61615785e-01 7.62340341e-01 -1.05090778 0.94877400 365.75 4.03514157e-01 -6.74782201e-01 7.86228143e-01 -1.03185482 0.96380078 366.00 3.97968458e-01 -7.17192772e-01 8.20209952e-01 -1.06420084 0.94445876 366.25 3.84094124e-01 -7.47594011e-01 8.40490989e-01 -1.09619059 0.95391865 366.50 3.79071867e-01 -7.63793594e-01 8.52687595e-01 -1.11011193 0.95826147 366.75 3.77187871e-01 -7.79856726e-01 8.66283558e-01 -1.12030350 0.96523546 367.00 3.29419002e-01 -8.01689358e-01 8.66731046e-01 -1.18092369 0.95940401 367.25 3.32866705e-01 -7.87512713e-01 8.54971646e-01 -1.17089148 0.95844116 367.50 3.79883120e-01 -7.88705930e-01 8.75424599e-01 -1.12193319 0.95117580 367.75 4.02698626e-01 -8.23458889e-01 9.16651910e-01 -1.11596069 0.95734410 368.00 3.72398649e-01 -8.95190064e-01 9.69559696e-01 -1.17657379 0.95208243 368.25 3.15456000e-01 -9.14440255e-01 9.67322835e-01 -1.23860808 0.94831965 368.50 2.34918032e-01 -8.79261865e-01 9.10103241e-01 -1.30971809 0.92111445 368.75 2.37845182e-01 -8.67041237e-01 8.99072209e-01 -1.30306410 0.93553683 369.00 2.63192620e-01 -9.28922270e-01 9.65487928e-01 -1.29470132 0.91736118 369.25 2.26183431e-01 -9.78970650e-01 1.00475991e+00 -1.34373843 0.91446720 369.50 1.48013300e-01 -9.57810573e-01 9.69179566e-01 -1.41747614 0.91535256 369.75 1.83886627e-01 -1.01788871e+00 1.03436537e+00 -1.39206907 0.91704331 370.00 4.13324063e-02 -1.17861774e+00 1.17934225e+00 -1.53574215 0.94584579 370.25 -8.97011276e-02 -1.09994132e+00 1.10359286e+00 -1.65216709 0.95169450 370.50 -9.70255058e-02 -9.25820103e-01 9.30890333e-01 -1.67521469 0.97435891 370.75 -4.38892099e-02 -9.11754287e-01 9.12810025e-01 -1.61889630 0.97092388 371.00 4.01351873e-02 -9.63117119e-01 9.63953016e-01 -1.52914825 0.97078530 371.25 2.73402387e-02 -9.95970871e-01 9.96346057e-01 -1.54335238 0.96481510 371.50 -4.35439107e-02 -1.08645534e+00 1.08732758e+00 -1.61085377 0.97168982 371.75 -1.17219622e-01 -1.11605748e+00 1.12219639e+00 -1.67544275 0.97022140 372.00 -2.22646850e-01 -1.18719377e+00 1.20789100e+00 -1.75618335 0.98008460 372.25 -3.24861096e-01 -1.17780730e+00 1.22178753e+00 -1.83992337 0.96525847 372.50 -5.96341888e-01 -1.18070522e+00 1.32275790e+00 -2.03849380 0.97005637 372.75 -6.98990022e-01 -1.09046238e+00 1.29525876e+00 -2.14082098 0.96532529 373.00 -8.08133412e-01 -9.22432990e-01 1.22636138e+00 -2.29024278 0.96594412 373.25 -8.26599185e-01 -7.30233138e-01 1.10295360e+00 -2.41801441 0.95587476 373.50 -8.03892727e-01 -5.43975773e-01 9.70645743e-01 -2.54669175 0.97116987 373.75 -7.30297937e-01 -4.61057388e-01 8.63660230e-01 -2.57845595 0.97541085 374.00 -6.84829695e-01 -4.15126591e-01 8.00825697e-01 -2.59664513 0.98517546 374.25 -6.68896215e-01 -3.62760696e-01 7.60931974e-01 -2.64465925 0.97755499 374.50 -5.99470814e-01 -2.94657153e-01 6.67973124e-01 -2.68474496 0.97705152 374.75 -5.36172357e-01 -2.32292593e-01 5.84329227e-01 -2.73276139 0.96331351 375.00 -4.79984419e-01 -1.80767369e-01 5.12895588e-01 -2.78141043 0.96954738 375.25 -3.78814685e-01 -1.95395047e-01 4.26239123e-01 -2.66538002 0.92814876 375.50 -2.79201511e-01 -2.22068631e-01 3.56746353e-01 -2.46968099 0.92298741 375.75 -2.17815063e-01 -2.98811549e-01 3.69772556e-01 -2.20068086 0.88259346 376.00 -2.06327019e-01 -3.93365962e-01 4.44193223e-01 -2.05386438 0.93187428 376.25 -2.96018744e-01 -5.21619481e-01 5.99761602e-01 -2.08697544 0.92753982 376.50 -3.69701594e-01 -5.88512265e-01 6.95000687e-01 -2.13169125 0.96237948 376.75 -5.33703768e-01 -5.54500169e-01 7.69616885e-01 -2.33708606 0.96038292 377.00 -6.30366353e-01 -4.90653006e-01 7.98812939e-01 -2.48018578 0.96709719 377.25 -6.72963688e-01 -3.25610521e-01 7.47597710e-01 -2.69095188 0.95321655 377.50 -6.99082634e-01 -2.26378245e-01 7.34822181e-01 -2.82842670 0.97019703 377.75 -6.35351970e-01 -9.01170785e-02 6.41711161e-01 -3.00069446 0.95580547 378.00 -5.89533013e-01 -9.01067357e-03 5.89601870e-01 -3.12630942 0.95718928 378.25 -4.82461786e-01 8.15172526e-02 4.89299946e-01 2.97421243 0.93851171 378.50 -4.15515542e-01 9.85180634e-02 4.27035097e-01 2.90879306 0.92993004 378.75 -3.06937675e-01 1.28974209e-01 3.32934051e-01 2.74379744 0.87585687 379.00 -2.40270642e-01 1.27785771e-01 2.72138172e-01 2.65279792 0.83276591 379.25 -1.10370192e-01 9.30761186e-02 1.44377086e-01 2.44099621 0.58661806 379.50 -8.10448788e-02 5.81096354e-02 9.97246314e-02 2.51954445 0.39941342 379.75 -2.86974263e-02 -6.24966757e-02 6.87704642e-02 -2.00126075 0.25869182 380.00 -3.12516896e-02 -1.08019143e-01 1.12449115e-01 -1.85242289 0.54438221 380.25 -4.76815988e-02 -1.73917012e-01 1.80334860e-01 -1.83838416 0.74747219 380.50 -6.06139652e-02 -1.92965365e-01 2.02261427e-01 -1.87515490 0.84678179 380.75 -8.33834280e-02 -2.05563110e-01 2.21830990e-01 -1.95615032 0.90634521 381.00 -9.31486233e-02 -2.11556524e-01 2.31155421e-01 -1.98555565 0.90578797 381.25 -9.39934335e-02 -2.02519063e-01 2.23268306e-01 -2.00533137 0.89838935 381.50 -9.20446931e-02 -2.12474523e-01 2.31554850e-01 -1.97959479 0.90187451 381.75 -8.67538254e-02 -2.40611662e-01 2.55773724e-01 -1.91684347 0.91977295 382.00 -8.73966956e-02 -2.63946326e-01 2.78039287e-01 -1.89054942 0.92224940 382.25 -1.13494712e-01 -3.14679826e-01 3.34521214e-01 -1.91694249 0.91690106 382.50 -1.44214486e-01 -3.16132335e-01 3.47472979e-01 -1.99878088 0.90354316 382.75 -2.32316927e-01 -3.11805752e-01 3.88836703e-01 -2.21113438 0.92693019 383.00 -2.53938615e-01 -2.55670371e-01 3.60350050e-01 -2.35279630 0.89796510 383.25 -2.87326657e-01 -1.93731884e-01 3.46538094e-01 -2.54835390 0.93598422 383.50 -2.59196908e-01 -1.56569614e-01 3.02815259e-01 -2.59819566 0.91080680 383.75 -2.21692738e-01 -1.23061913e-01 2.53558483e-01 -2.63484138 0.88377642 384.00 -1.86404995e-01 -1.03804922e-01 2.13359518e-01 -2.63348384 0.81713744 384.25 -1.25821045e-01 -1.18867799e-01 1.73090985e-01 -2.38460353 0.82012835 384.50 -9.23015155e-02 -1.33864568e-01 1.62601637e-01 -2.17445009 0.78334068 384.75 -5.23959338e-02 -1.57966653e-01 1.66429557e-01 -1.89106701 0.78303431 385.00 -4.11528836e-02 -1.92135173e-01 1.96492963e-01 -1.78179541 0.77106464 385.25 -2.01875631e-02 -2.46888900e-01 2.47712872e-01 -1.65238263 0.85278180 385.50 -2.69126241e-02 -2.89767316e-01 2.91014410e-01 -1.66340732 0.86094882 385.75 -4.87853411e-02 -3.39598175e-01 3.43084436e-01 -1.71347625 0.90139237 386.00 -1.01590988e-01 -3.92775998e-01 4.05701508e-01 -1.82389820 0.87367627 386.25 -1.64477192e-01 -4.37778355e-01 4.67656535e-01 -1.93018829 0.90339052 386.50 -2.35804798e-01 -3.86280146e-01 4.52566298e-01 -2.11886440 0.86966758 386.75 -2.72532197e-01 -3.03064438e-01 4.07580485e-01 -2.30319965 0.90538522 387.00 -2.53381180e-01 -2.47034989e-01 3.53876120e-01 -2.36887564 0.92058690 387.25 -2.33339944e-01 -2.31897265e-01 3.28973967e-01 -2.35929543 0.92389567 387.50 -2.11885052e-01 -2.50942451e-01 3.28431712e-01 -2.27200529 0.90918122 387.75 -1.96885996e-01 -2.60397072e-01 3.26451727e-01 -2.21818946 0.92628970 388.00 -1.91314399e-01 -2.75309894e-01 3.35256226e-01 -2.17809507 0.91392325 388.25 -1.96682416e-01 -2.82832840e-01 3.44497297e-01 -2.17842946 0.94225942 388.50 -2.20081391e-01 -2.85554315e-01 3.60523349e-01 -2.22742463 0.95188776 388.75 -2.23461805e-01 -2.77167632e-01 3.56029598e-01 -2.24932659 0.95318138 389.00 -2.26800534e-01 -2.68200629e-01 3.51240743e-01 -2.27275233 0.95854065 389.25 -2.23033564e-01 -2.62822790e-01 3.44702465e-01 -2.27448180 0.96284031 389.50 -2.12359697e-01 -2.55912647e-01 3.32547626e-01 -2.26345356 0.95901038 389.75 -2.05608462e-01 -2.56770278e-01 3.28946524e-01 -2.24599362 0.96232694 390.00 -1.77284208e-01 -2.79042186e-01 3.30596781e-01 -2.13679035 0.95465997 390.25 -1.71520321e-01 -2.88772321e-01 3.35870025e-01 -2.10676566 0.95659100 390.50 -1.74853108e-01 -3.05442193e-01 3.51949631e-01 -2.09071882 0.95905480 390.75 -1.75447757e-01 -3.14060175e-01 3.59743949e-01 -2.08025159 0.94527656 391.00 -2.00220728e-01 -3.31570488e-01 3.87333614e-01 -2.11404608 0.95235777 391.25 -2.08931061e-01 -3.36069323e-01 3.95720581e-01 -2.12701214 0.95386187 391.50 -1.99390160e-01 -3.19391913e-01 3.76520425e-01 -2.12887812 0.92951086 391.75 -2.04596067e-01 -3.42751901e-01 3.99172163e-01 -2.10894934 0.91967573 392.00 -2.12690373e-01 -3.81609357e-01 4.36878583e-01 -2.07926581 0.94267693 392.25 -2.16279020e-01 -3.95064039e-01 4.50391174e-01 -2.07168202 0.94784425 392.50 -2.46847701e-01 -4.28884323e-01 4.94849018e-01 -2.09304968 0.96205617 392.75 -2.81325724e-01 -4.56427777e-01 5.36162735e-01 -2.12316148 0.94970192 393.00 -3.44057888e-01 -4.82746070e-01 5.92806544e-01 -2.19000157 0.91717720 393.25 -3.88815708e-01 -4.76427003e-01 6.14947432e-01 -2.25528211 0.91877926 393.50 -4.43516051e-01 -4.14237136e-01 6.06876341e-01 -2.39031567 0.91467752 393.75 -4.98513990e-01 -3.53078739e-01 6.10885254e-01 -2.52534292 0.91207295 394.00 -5.20655654e-01 -2.67504062e-01 5.85355220e-01 -2.66697948 0.91622603 394.25 -4.64852951e-01 -1.93331686e-01 5.03453480e-01 -2.74745617 0.89039206 394.50 -3.65344444e-01 -1.44975098e-01 3.93057682e-01 -2.76383275 0.84014864 394.75 -2.71531628e-01 -1.70309278e-01 3.20522503e-01 -2.58140061 0.71779580 395.00 -1.91735963e-01 -3.23836226e-01 3.76341044e-01 -2.10536968 0.76925602 395.25 -2.11663146e-01 -4.71218748e-01 5.16573708e-01 -1.99297009 0.83383827 395.50 -2.46943458e-01 -5.88243523e-01 6.37974540e-01 -1.96825260 0.84933763 395.75 -4.84606941e-01 -6.58739413e-01 8.17790622e-01 -2.20505521 0.81559503 396.00 -8.28988497e-01 -6.52523027e-01 1.05499205e+00 -2.47474771 0.90951692 396.25 -9.38120824e-01 -3.39835678e-01 9.97777013e-01 -2.79404532 0.91055908 396.50 -9.22696796e-01 -1.43603346e-01 9.33804743e-01 -2.98719691 0.96175617 396.75 -8.30020872e-01 -4.16085339e-02 8.31063125e-01 -3.09150508 0.95417371 397.00 -7.60524321e-01 5.68981690e-03 7.60545604e-01 3.13411135 0.96959603 397.25 -6.87215498e-01 4.70389873e-02 6.88823495e-01 3.07325058 0.96446769 397.50 -6.20562268e-01 7.35408031e-02 6.24904615e-01 3.02363606 0.95857677 397.75 -5.17214667e-01 1.01418225e-01 5.27064198e-01 2.94796399 0.95324803 398.00 -4.59734787e-01 8.12864307e-02 4.66865675e-01 2.96658979 0.96508888 398.25 -4.27820285e-01 3.84669345e-02 4.29546158e-01 3.05192002 0.95755169 398.50 -3.97276485e-01 1.71215187e-02 3.97645259e-01 3.09852207 0.96528360 398.75 -3.95568455e-01 -2.05487459e-02 3.96101822e-01 -3.08969192 0.96817148 399.00 -3.95970256e-01 -2.97479171e-02 3.97086115e-01 -3.06660687 0.97129465 399.25 -3.90205206e-01 -3.86542410e-02 3.92115102e-01 -3.04285348 0.97365816 399.50 -3.88313671e-01 -4.49201988e-02 3.90903225e-01 -3.02642437 0.97763965 399.75 -3.97672036e-01 -4.33661530e-02 4.00029588e-01 -3.03297182 0.97061227 400.00 -3.93591826e-01 -2.94197361e-02 3.94689811e-01 -3.06698458 0.96986118 400.25 -3.75583612e-01 -2.10278594e-03 3.75589498e-01 -3.13599400 0.95634364 400.50 -3.46871538e-01 7.86175092e-03 3.46960618e-01 3.11893180 0.93874706 400.75 -2.82767733e-01 2.23288690e-02 2.83647967e-01 3.06279077 0.92406045 401.00 -2.46160452e-01 3.37363963e-03 2.46183568e-01 3.12788847 0.87987136 401.25 -1.71607061e-01 -7.85595812e-02 1.88734181e-01 -2.71228148 0.76580712 401.50 -1.57054161e-01 -1.38088625e-01 2.09127898e-01 -2.42036511 0.75366259 401.75 -1.52127404e-01 -2.89924440e-01 3.27412474e-01 -2.05401908 0.86924002 402.00 -1.96472267e-01 -3.72279342e-01 4.20943298e-01 -2.05640057 0.86651489 402.25 -3.16823252e-01 -5.17227010e-01 6.06548228e-01 -2.12038686 0.93413749 402.50 -4.21716041e-01 -5.72737485e-01 7.11247247e-01 -2.20548230 0.92956939 402.75 -6.61236375e-01 -5.73100881e-01 8.75030378e-01 -2.42747660 0.93196275 403.00 -8.27344481e-01 -4.81517469e-01 9.57265879e-01 -2.61451091 0.93123121 403.25 -9.62151303e-01 -2.68740497e-01 9.98977769e-01 -2.86922196 0.94296679 403.50 -1.03437306e+00 -1.63583590e-01 1.04722835e+00 -2.98474410 0.93324832 403.75 -1.06718526e+00 8.67115849e-02 1.07070223e+00 3.06051815 0.92054054 404.00 -9.64207027e-01 2.80409278e-01 1.00415365e+00 2.85858036 0.90183885 404.25 -8.19070642e-01 5.29968069e-01 9.75573098e-01 2.56730402 0.93361857 404.50 -6.98211324e-01 6.09853442e-01 9.27049229e-01 2.42364059 0.89016070 404.75 -3.70519144e-01 6.58402322e-01 7.55498546e-01 2.08337941 0.86670257 405.00 -1.64695443e-01 5.62421564e-01 5.86039763e-01 1.85566475 0.79934758 405.25 -2.06281832e-02 4.13254684e-01 4.13769206e-01 1.62067132 0.81114727 405.50 7.90126145e-03 1.97736182e-01 1.97893981e-01 1.53085897 0.42045196 405.75 -2.47299683e-02 -2.02393718e-02 3.19562748e-02 -2.45572360 0.03321084 406.00 -1.54683299e-01 -9.34161751e-02 1.80702808e-01 -2.59829656 0.48326719 406.25 -2.95518130e-01 -9.46792332e-02 3.10314554e-01 -2.83154156 0.80738409 406.50 -3.67820055e-01 -2.64641214e-02 3.68770854e-01 -3.06976786 0.85581223 406.75 -4.12098366e-01 4.55721791e-02 4.14610524e-01 3.03145448 0.85419110 407.00 -4.10551474e-01 1.32537658e-01 4.31414816e-01 2.82932618 0.84953974 407.25 -4.09699038e-01 1.97412940e-01 4.54780354e-01 2.69257126 0.89939394 407.50 -3.54875895e-01 2.35021414e-01 4.25643003e-01 2.55664447 0.87175830 407.75 -3.01862142e-01 2.42118640e-01 3.86965358e-01 2.46558258 0.87422667 408.00 -2.92650182e-01 2.92046262e-01 4.13443041e-01 2.35722737 0.84916973 408.25 -2.84439373e-01 3.15672216e-01 4.24917292e-01 2.30419635 0.89175941 408.50 -2.31205421e-01 3.42123165e-01 4.12921551e-01 2.16509254 0.83896498 408.75 -1.81474275e-01 3.79510355e-01 4.20667353e-01 2.01683609 0.87820113 409.00 -7.58596535e-02 4.53116573e-01 4.59422807e-01 1.73667548 0.84776882 409.25 1.04536043e-02 4.63519228e-01 4.63637091e-01 1.54824746 0.85094247 409.50 1.34843554e-01 3.92671197e-01 4.15178820e-01 1.24001269 0.81383978 409.75 1.95105132e-01 3.51412454e-01 4.01941196e-01 1.06396752 0.83593991 410.00 2.51234957e-01 2.90258754e-01 3.83886895e-01 0.85734073 0.72831923 410.25 2.97868173e-01 2.88375807e-01 4.14591431e-01 0.76920774 0.77261841 410.50 3.59091582e-01 2.32565770e-01 4.27824265e-01 0.57472163 0.79864833 410.75 4.16679974e-01 1.59681169e-01 4.46228951e-01 0.36595994 0.80178756 411.00 4.91753056e-01 9.05597659e-02 5.00022139e-01 0.18211654 0.85198136 411.25 5.54790120e-01 5.80170243e-02 5.57815428e-01 0.10419600 0.83690555 411.50 6.40052886e-01 -6.56586614e-02 6.43411810e-01 -0.10222560 0.84917410 411.75 6.44738298e-01 -1.32682319e-01 6.58249247e-01 -0.20295904 0.84265765 412.00 6.67457659e-01 -2.25587577e-01 7.04549134e-01 -0.32592703 0.75121036 412.25 6.94871912e-01 -3.25459351e-01 7.67313993e-01 -0.43802756 0.72445206 412.50 7.81960208e-01 -4.18069785e-01 8.86704072e-01 -0.49097664 0.73710624 412.75 7.11004031e-01 -4.93090936e-01 8.65254531e-01 -0.60635937 0.64827112 413.00 6.92291883e-01 -7.97982803e-01 1.05643012e+00 -0.85620005 0.76246164 413.25 6.09867841e-01 -8.58034838e-01 1.05269301e+00 -0.95287681 0.67017810 413.50 1.86341431e-02 -8.91422228e-01 8.91616969e-01 -1.54989554 0.46568205 413.75 -1.43017464e-01 -9.74409953e-01 9.84849609e-01 -1.71652919 0.56584297 414.00 -2.88782332e-01 -1.11537312e+00 1.15215122e+00 -1.82414404 0.65469732 414.25 -5.34337448e-01 -9.78213658e-01 1.11463827e+00 -2.07074664 0.46883805 414.50 -1.23630793e+00 -6.25438069e-01 1.38550715e+00 -2.67324270 0.42014192 414.75 -9.78433752e-01 -6.26898975e-02 9.80440018e-01 -3.07760843 0.20371585 415.00 -2.73249794e-01 1.19068880e+00 1.22164040e+00 1.79637918 0.38903386 415.25 5.22748798e-01 1.42483928e+00 1.51770659e+00 1.21916117 0.62854262 415.50 9.75924680e-01 1.40340878e+00 1.70938152e+00 0.96316707 0.83505366 415.75 1.23782943e+00 1.18324071e+00 1.71239022e+00 0.76285463 0.81518843 416.00 1.63044603e+00 9.67992693e-01 1.89614454e+00 0.53577286 0.84890669 416.25 1.97809719e+00 7.75263273e-01 2.12459447e+00 0.37352476 0.86987299 416.50 2.27461253e+00 4.49081819e-01 2.31852035e+00 0.19492533 0.90787199 416.75 2.41108465e+00 1.90984260e-01 2.41863684e+00 0.07904589 0.93147609 417.00 2.59128528e+00 2.08703165e-01 2.59967621e+00 0.08036693 0.95907240 417.25 2.83444483e+00 1.57159923e-01 2.83879847e+00 0.05538974 0.94442261 417.50 3.03103459e+00 1.50516368e-01 3.03476949e+00 0.04961765 0.95307456 417.75 3.40261409e+00 1.81724123e-01 3.40746332e+00 0.05335652 0.94612337 418.00 3.87182461e+00 3.05512441e-01 3.88385938e+00 0.07874343 0.94930993 418.25 4.70312463e+00 3.69325749e-01 4.71760350e+00 0.07836692 0.93800482 418.50 5.34479852e+00 2.58971753e-01 5.35106883e+00 0.04841518 0.94485559 418.75 6.45667937e+00 5.35801517e-01 6.47887272e+00 0.08279436 0.84328779 419.00 7.82137942e+00 5.98043377e-01 7.84421009e+00 0.07631415 0.86693789 419.25 1.00833415e+01 4.47118802e-03 1.00833425e+01 0.00044342 0.75590165 419.50 1.26937869e+01 -1.24755763e+00 1.27549452e+01 -0.09796635 0.74395221 419.75 9.95283510e+00 -3.60642398e+00 1.05860862e+01 -0.34763566 0.40656973 420.00 4.86473229e+00 -6.15617918e+00 7.84628335e+00 -0.90204768 0.20488513 420.25 -6.05702286e-01 -1.08328270e+01 1.08497472e+01 -1.62665176 0.35570161 420.50 -9.73528552e-01 -1.19623617e+01 1.20019104e+01 -1.65200001 0.50069014 420.75 -2.77092502e+00 -1.27787733e+01 1.30757437e+01 -1.78432872 0.58160546 421.00 -4.20950170e+00 -1.30529685e+01 1.37149514e+01 -1.88275981 0.64631479 421.25 -5.79903260e+00 -1.23433795e+01 1.36377343e+01 -2.01000088 0.75770855 421.50 -6.82778974e+00 -1.18009938e+01 1.36338610e+01 -2.09531505 0.78445445 421.75 -7.28385346e+00 -9.39560034e+00 1.18883063e+01 -2.23025687 0.81430449 422.00 -7.17472536e+00 -9.04957255e+00 1.15486557e+01 -2.24114680 0.83573139 422.25 -5.54554214e+00 -7.67723809e+00 9.47064002e+00 -2.19635585 0.88592317 422.50 -4.28757435e+00 -7.14339359e+00 8.33134838e+00 -2.11137414 0.87549306 422.75 -2.30010703e+00 -6.08441412e+00 6.50465891e+00 -1.93222308 0.86484926 423.00 -9.23654320e-01 -5.76815934e+00 5.84164355e+00 -1.72957817 0.84879313 423.25 1.70590829e+00 -5.69010331e+00 5.94031975e+00 -1.27952056 0.83630002 423.50 3.07950290e+00 -5.04971335e+00 5.91463803e+00 -1.02317499 0.76782249 423.75 6.29802106e+00 -3.06548725e+00 7.00444725e+00 -0.45298197 0.77581007 424.00 7.14343964e+00 -2.36081651e+00 7.52344233e+00 -0.31918700 0.78197306 424.25 7.99534984e+00 7.85124101e-01 8.03380600e+00 0.09788377 0.78837237 424.50 6.98477099e+00 2.14580013e+00 7.30694766e+00 0.29805941 0.75110597 424.75 5.81138467e+00 3.38813750e+00 6.72693596e+00 0.52783858 0.80873368 425.00 5.23614447e+00 4.56376507e+00 6.94587364e+00 0.71689474 0.81442787 425.25 4.88239840e+00 5.85306091e+00 7.62208214e+00 0.87556946 0.87481975 425.50 4.42406573e+00 5.81638122e+00 7.30771155e+00 0.92053192 0.85730916 425.75 4.46984733e+00 5.89991333e+00 7.40192627e+00 0.92244107 0.88474337 426.00 3.99836310e+00 5.72458643e+00 6.98267837e+00 0.96110837 0.87398007 426.25 4.09372580e+00 5.19865648e+00 6.61699480e+00 0.90374961 0.86832901 426.50 4.28466907e+00 4.51684528e+00 6.22577548e+00 0.81177117 0.85802545 426.75 4.46885711e+00 4.04990506e+00 6.03095472e+00 0.73625783 0.90816147 427.00 3.75150981e+00 3.36682198e+00 5.04076543e+00 0.73140883 0.87612519 427.25 3.41348029e+00 2.74361158e+00 4.37941231e+00 0.67702812 0.91176991 427.50 2.83689773e+00 1.95891303e+00 3.44751055e+00 0.60433002 0.86920497 427.75 2.43348941e+00 1.65096965e+00 2.94067535e+00 0.59610720 0.87652269 428.00 2.04897917e+00 1.29242711e+00 2.42253658e+00 0.56273516 0.86468049 428.25 1.66020001e+00 1.08418489e+00 1.98285677e+00 0.57851266 0.86406511 428.50 9.98303995e-01 7.05291627e-01 1.22231221e+00 0.61506829 0.74048696 428.75 6.08037279e-01 5.02967670e-01 7.89104435e-01 0.69110692 0.58298791 429.00 -1.26713935e-01 3.82063443e-01 4.02528130e-01 1.89103724 0.29979935 429.25 -5.00523922e-01 4.08175723e-01 6.45857273e-01 2.45747353 0.60657692 429.50 -1.03456822e+00 7.24025912e-01 1.26275291e+00 2.53097817 0.79489711 429.75 -1.39761614e+00 1.06776492e+00 1.75882142e+00 2.48919783 0.87839419 430.00 -1.50439494e+00 1.71074314e+00 2.27812340e+00 2.29210220 0.88218929 430.25 -1.53797325e+00 2.00707629e+00 2.52858003e+00 2.22463260 0.93399483 430.50 -1.44691398e+00 2.06178342e+00 2.51883126e+00 2.18271450 0.92014830 430.75 -1.42827579e+00 2.05221742e+00 2.50031359e+00 2.17881051 0.91775164 431.00 -1.55717970e+00 2.01587216e+00 2.54726308e+00 2.22851728 0.93723835 431.25 -1.64740375e+00 2.10393248e+00 2.67216597e+00 2.23509237 0.94506648 431.50 -1.70749181e+00 2.45725403e+00 2.99226096e+00 2.17807644 0.92680955 431.75 -1.86309863e+00 2.89900033e+00 3.44606143e+00 2.14200091 0.93910872 432.00 -1.77629617e+00 3.52409956e+00 3.94645484e+00 2.03767275 0.93731901 432.25 -1.45060984e+00 3.73673432e+00 4.00842267e+00 1.94109131 0.92006594 432.50 -6.17569228e-01 3.62750367e+00 3.67969762e+00 1.73942590 0.88995388 432.75 -1.98233580e-01 3.45607528e+00 3.46175575e+00 1.62809155 0.90988063 433.00 -8.34497127e-02 3.16840185e+00 3.16950061e+00 1.59712835 0.95080956 433.25 -1.59748252e-01 3.06195359e+00 3.06611795e+00 1.62292107 0.94614160 433.50 -3.60950013e-01 2.88001278e+00 2.90254345e+00 1.69547555 0.93850673 433.75 -3.36765303e-01 2.84786022e+00 2.86770269e+00 1.68850176 0.92663066 434.00 -3.43769814e-01 2.85137414e+00 2.87202231e+00 1.69078008 0.92794112 434.25 -4.14793055e-01 2.87424884e+00 2.90402474e+00 1.71412037 0.92046996 434.50 -6.43595119e-01 2.86974825e+00 2.94103208e+00 1.79141473 0.90656432 434.75 -8.95728729e-01 2.93288120e+00 3.06661411e+00 1.86720822 0.91634001 435.00 -1.40242497e+00 3.26168830e+00 3.55040933e+00 1.97686825 0.89077989 435.25 -1.51379714e+00 3.62573156e+00 3.92905983e+00 1.96631003 0.80777684 435.50 -1.09479436e+00 4.13585350e+00 4.27830094e+00 1.82956939 0.52938196 435.75 1.21164363e+00 2.64586097e+00 2.91009631e+00 1.14135975 0.21170136 436.00 4.15805726e+00 2.86746560e-01 4.16793279e+00 0.06885266 0.47972205 436.25 3.31132613e+00 -9.75664850e-03 3.31134050e+00 -0.00294644 0.62197011 436.50 3.21141713e+00 1.27669241e-01 3.21395386e+00 0.03973387 0.82600486 436.75 3.05377208e+00 2.17544757e-01 3.06151101e+00 0.07111790 0.85704813 437.00 3.19048033e+00 1.49307027e-01 3.19397203e+00 0.04676355 0.87028401 437.25 3.23244028e+00 6.14767468e-02 3.23302483e+00 0.01901639 0.88187867 437.50 3.29969563e+00 -1.39601302e-02 3.29972516e+00 -0.00423071 0.91142019 437.75 3.42461003e+00 -3.96850490e-01 3.44752725e+00 -0.11536738 0.84493459 438.00 3.33667339e+00 -1.07541023e+00 3.50569487e+00 -0.31178802 0.85238342 438.25 3.07282305e+00 -1.62420384e+00 3.47566966e+00 -0.48624197 0.80072425 438.50 3.07855238e+00 -2.29960677e+00 3.84261317e+00 -0.64156336 0.87978336 438.75 2.84137371e+00 -2.57927870e+00 3.83745791e+00 -0.73708460 0.83756160 439.00 2.69208451e+00 -2.86041588e+00 3.92801451e+00 -0.81570520 0.85136372 439.25 2.52296434e+00 -3.17003097e+00 4.05147447e+00 -0.89857262 0.77660625 439.50 2.31068119e+00 -3.47486598e+00 4.17300146e+00 -0.98396935 0.72440664 439.75 3.08283318e+00 -3.76320353e+00 4.86472622e+00 -0.88445454 0.67008839 440.00 3.77355070e+00 -4.78170287e+00 6.09133542e+00 -0.90269734 0.69429388 440.25 4.97956207e+00 -5.20608819e+00 7.20412331e+00 -0.80763423 0.65413512 440.50 6.36435176e+00 -4.33694338e+00 7.70156161e+00 -0.59816278 0.58068261 440.75 6.79123635e+00 3.18041030e+00 7.49906000e+00 0.43797654 0.53255073 441.00 4.45441843e+00 4.87806089e+00 6.60585510e+00 0.83076144 0.59007591 441.25 1.53227134e+00 5.18384647e+00 5.40556377e+00 1.28339417 0.73698785 441.50 3.19773279e-01 5.00405330e+00 5.01426011e+00 1.50698025 0.79002603 441.75 -1.05402344e+00 4.30682025e+00 4.43392220e+00 1.81081223 0.82385526 442.00 -1.22079447e+00 4.30624211e+00 4.47594239e+00 1.84704221 0.83423147 442.25 -8.66453010e-01 4.56209366e+00 4.64364505e+00 1.75848533 0.81249309 442.50 -8.73799719e-01 4.86678301e+00 4.94460340e+00 1.74844715 0.83950277 442.75 3.63636354e-01 4.96100002e+00 4.97430925e+00 1.49762817 0.76706849 443.00 1.17781171e+00 4.13175995e+00 4.29635667e+00 1.29309894 0.78164007 443.25 1.12531663e+00 3.18935747e+00 3.38206130e+00 1.23159822 0.87397530 443.50 9.98761189e-01 3.03665458e+00 3.19668499e+00 1.25303943 0.90462814 443.75 1.09519566e+00 3.18780204e+00 3.37068767e+00 1.23987176 0.88765311 444.00 1.34130908e+00 3.01342115e+00 3.29845677e+00 1.15201492 0.87253539 444.25 1.86802496e+00 2.42724672e+00 3.06284898e+00 0.91486466 0.85934001 444.50 2.20986257e+00 1.98764816e+00 2.97224458e+00 0.73250797 0.82818983 444.75 2.22443326e+00 7.16550867e-01 2.33699561e+00 0.31163153 0.70912958 445.00 1.52727785e+00 1.05388952e-01 1.53090968e+00 0.06889523 0.58804314 445.25 7.77518942e-01 -2.10524922e-01 8.05516262e-01 -0.26442472 0.43101890 445.50 3.30793155e-01 -2.13116018e-01 3.93500379e-01 -0.57232781 0.14149081 445.75 -2.74065616e-01 -1.84788524e-01 3.30543130e-01 -2.54835895 0.10411284 446.00 -5.71725554e-01 -2.20607298e-02 5.72151016e-01 -3.10302556 0.24668194 446.25 -9.02780107e-01 4.74517486e-01 1.01989155e+00 2.65766130 0.56190866 446.50 -1.05222993e+00 8.34647155e-01 1.34306504e+00 2.47100111 0.68681987 446.75 -1.23042320e+00 1.32456742e+00 1.80787723e+00 2.31936396 0.80824060 447.00 -9.70455314e-01 1.78240404e+00 2.02946980e+00 2.06937953 0.81144708 447.25 -4.79025003e-01 2.15619633e+00 2.20876608e+00 1.78940793 0.88913947 447.50 -1.49574689e-01 2.31023210e+00 2.31506910e+00 1.63545053 0.90907499 447.75 1.78944237e-01 2.52799265e+00 2.53431803e+00 1.50012909 0.91815958 448.00 6.51840338e-01 2.50453595e+00 2.58797143e+00 1.31618108 0.90199092 448.25 1.16784754e+00 2.14508562e+00 2.44238821e+00 1.07224007 0.88591915 448.50 1.39372882e+00 1.45152753e+00 2.01231514e+00 0.80570943 0.82755409 448.75 1.59268824e+00 9.40233868e-01 1.84951225e+00 0.53328921 0.86390533 449.00 1.54144781e+00 4.29271436e-01 1.60010478e+00 0.27160410 0.81618378 449.25 1.29891070e+00 1.74003212e-01 1.31051369e+00 0.13316806 0.84138257 449.50 1.02080350e+00 -8.18341152e-02 1.02407842e+00 -0.07999530 0.70146636 449.75 8.33243260e-01 -1.99519976e-01 8.56797848e-01 -0.23502473 0.59502955 450.00 6.25554983e-01 -2.11637211e-01 6.60385755e-01 -0.32623103 0.65054945 450.25 4.82815517e-01 -2.09983532e-01 5.26501574e-01 -0.41023837 0.68436624 450.50 3.25359804e-01 -2.08747920e-01 3.86567841e-01 -0.57044106 0.59767008 450.75 2.50877677e-01 -2.08204961e-01 3.26019807e-01 -0.69271234 0.54515419 451.00 1.95122224e-01 -1.89089564e-01 2.71712248e-01 -0.76969806 0.52181434 451.25 1.66674414e-01 -1.79350861e-01 2.44840952e-01 -0.82201624 0.49107792 451.50 1.29958557e-01 -1.57215400e-01 2.03975265e-01 -0.88002873 0.33310645 451.75 1.23327064e-01 -1.72526809e-01 2.12073253e-01 -0.95018758 0.32148421 452.00 1.49216063e-01 -2.35820045e-01 2.79063662e-01 -1.00664056 0.46823649 452.25 1.28159598e-01 -2.98026463e-01 3.24414326e-01 -1.16467499 0.50892587 452.50 5.87704778e-03 -3.65250289e-01 3.65297568e-01 -1.55470725 0.53441599 452.75 -5.66207826e-02 -3.95037219e-01 3.99074325e-01 -1.71315699 0.60574719 453.00 -1.19943200e-01 -3.90056021e-01 4.08080961e-01 -1.86912185 0.42958934 453.25 -1.70870313e-01 -3.31297399e-01 3.72766187e-01 -2.04697317 0.33277156 453.50 -1.87460915e-01 -4.58525861e-01 4.95366087e-01 -1.95889486 0.51028229 453.75 -1.89137842e-01 -5.12821247e-01 5.46588286e-01 -1.92413641 0.49089671 454.00 -1.34952699e-01 -7.17793413e-01 7.30369506e-01 -1.75663739 0.40892071 454.25 -1.82845339e-01 -9.66530289e-01 9.83673329e-01 -1.75776387 0.37033475 454.50 -1.08811609e+00 -1.37607509e+00 1.75430308e+00 -2.23986468 0.53824989 454.75 -1.46247088e+00 -1.13736417e+00 1.85267869e+00 -2.48059771 0.52623252 455.00 -1.77518753e+00 -5.48706277e-01 1.85805526e+00 -2.84181044 0.66995816 455.25 -1.74955430e+00 -3.78799826e-01 1.79009206e+00 -2.92837157 0.68354879 455.50 -1.57664484e+00 -2.37007938e-01 1.59435934e+00 -2.99238562 0.74603817 455.75 -1.24667917e+00 -2.01175009e-01 1.26280653e+00 -2.98160313 0.67081510 456.00 -8.80377416e-01 -1.60738252e-01 8.94930825e-01 -2.96100297 0.50065917 456.25 -8.59085746e-01 -4.84285872e-01 9.86185137e-01 -2.62827510 0.48409548 456.50 -7.54600210e-01 -7.90989406e-01 1.09319976e+00 -2.33265495 0.62010118 456.75 -9.70257049e-01 -9.89761760e-01 1.38601121e+00 -2.34624353 0.71937318 457.00 -1.25946646e+00 -1.23898151e+00 1.76672889e+00 -2.36439338 0.86111725 457.25 -1.45196592e+00 -1.35555452e+00 1.98638694e+00 -2.39052141 0.84969478 457.50 -1.87654981e+00 -1.46051588e+00 2.37792889e+00 -2.48022512 0.87380825 457.75 -2.14105835e+00 -1.28189147e+00 2.49547122e+00 -2.60211589 0.87885122 458.00 -2.50826916e+00 -1.04517182e+00 2.71731454e+00 -2.74678127 0.91597006 458.25 -2.78301675e+00 -7.61131609e-01 2.88522157e+00 -2.87462936 0.92991757 458.50 -3.06161098e+00 -4.20074486e-01 3.09029519e+00 -3.00523706 0.95060091 458.75 -3.12532129e+00 -1.55505990e-01 3.12918764e+00 -3.09187685 0.94366114 459.00 -3.18028730e+00 -9.07047126e-02 3.18158052e+00 -3.11307947 0.96507869 459.25 -3.24612389e+00 1.20973428e-01 3.24837727e+00 3.10434285 0.96875072 459.50 -3.34227441e+00 3.45157222e-01 3.36004936e+00 3.03868728 0.97844580 459.75 -3.48349495e+00 6.41463350e-01 3.54206328e+00 2.95948906 0.97884655 460.00 -3.57382581e+00 7.89654027e-01 3.66002520e+00 2.92413179 0.98120330 460.25 -3.51856419e+00 1.13041349e+00 3.69569055e+00 2.83073697 0.96617327 460.50 -3.55640255e+00 1.38339288e+00 3.81598938e+00 2.77061651 0.96676445 460.75 -3.50488317e+00 1.68583075e+00 3.88924561e+00 2.69326443 0.93828115 461.00 -3.31992160e+00 2.00285586e+00 3.87728140e+00 2.59876188 0.94572714 461.25 -3.09992731e+00 2.26284272e+00 3.83796906e+00 2.51103683 0.95052023 461.50 -3.10329574e+00 2.35835889e+00 3.89773025e+00 2.49175200 0.93712926 461.75 -2.66010217e+00 3.27757025e+00 4.22120958e+00 2.25257534 0.89261253 462.00 -2.28482385e+00 3.54623956e+00 4.21855841e+00 2.14315043 0.90446669 462.25 -1.42086326e+00 3.33217164e+00 3.62246053e+00 1.97385861 0.91940028 462.50 -1.17525044e+00 3.20728185e+00 3.41582647e+00 1.92203418 0.93898399 462.75 -7.76348443e-01 2.94032068e+00 3.04108576e+00 1.82894044 0.92284179 463.00 -7.05023553e-01 2.67807063e+00 2.76931770e+00 1.82821367 0.92675396 463.25 -7.25975534e-01 2.36321274e+00 2.47220851e+00 1.86884414 0.93152533 463.50 -6.90982060e-01 2.28810708e+00 2.39016531e+00 1.86407645 0.93484472 463.75 -5.20554348e-01 2.36695013e+00 2.42351599e+00 1.78727624 0.92156976 464.00 -6.22797042e-01 2.47882791e+00 2.55586853e+00 1.81694790 0.91970245 464.25 -4.19053429e-01 2.60870577e+00 2.64214905e+00 1.73007216 0.90485403 464.50 -2.02344455e-01 2.58346764e+00 2.59137962e+00 1.64895957 0.91482633 464.75 1.67522664e-01 2.49314777e+00 2.49876963e+00 1.50370394 0.91347401 465.00 4.98410214e-01 2.42468714e+00 2.47538289e+00 1.36806373 0.89081979 465.25 6.81626666e-01 1.75399309e+00 1.88178285e+00 1.20014364 0.82002068 465.50 4.54590145e-01 1.38462778e+00 1.45734220e+00 1.25357161 0.80350312 465.75 2.08753721e-01 1.28715948e+00 1.30397762e+00 1.41001454 0.88008296 466.00 9.67898519e-02 1.28791278e+00 1.29154466e+00 1.49578484 0.91151344 466.25 -1.83924759e-02 1.23130793e+00 1.23144529e+00 1.58573256 0.93323402 466.50 -8.33359595e-02 1.16284421e+00 1.16582655e+00 1.64233964 0.92010164 466.75 -1.34721182e-01 1.13159619e+00 1.13958753e+00 1.68929269 0.95275998 467.00 -1.90800941e-01 1.20307706e+00 1.21811306e+00 1.72808050 0.95947239 467.25 -1.50581508e-01 1.28332598e+00 1.29213016e+00 1.68759915 0.96135544 467.50 -2.88637224e-02 1.16323370e+00 1.16359174e+00 1.59560458 0.95809595 467.75 -1.95382577e-02 1.05291644e+00 1.05309770e+00 1.58935052 0.97031769 468.00 -7.21345087e-02 9.82477395e-01 9.85121931e-01 1.64408586 0.96413959 468.25 -7.36160542e-02 9.39909550e-01 9.42788039e-01 1.64895925 0.96107162 468.50 -1.21943828e-01 8.70459456e-01 8.78959591e-01 1.70998185 0.96591195 468.75 -1.57056484e-01 8.14968531e-01 8.29964123e-01 1.76117716 0.97033228 469.00 -2.24119081e-01 7.70366906e-01 8.02305759e-01 1.85390689 0.95529083 469.25 -3.31544242e-01 7.23104569e-01 7.95488404e-01 2.00069724 0.95217850 469.50 -4.65410993e-01 7.31826339e-01 8.67281490e-01 2.13723695 0.95635398 469.75 -5.90457159e-01 7.68859338e-01 9.69424746e-01 2.22569632 0.95560484 470.00 -6.52901412e-01 8.97529539e-01 1.10988266e+00 2.19970385 0.94518364 470.25 -6.44185543e-01 1.03187831e+00 1.21644887e+00 2.12888090 0.96105722 470.50 -5.82225533e-01 1.13858214e+00 1.27881033e+00 2.04349070 0.96282772 470.75 -4.98740754e-01 1.20644043e+00 1.30546576e+00 1.96279957 0.95710028 471.00 -3.84056027e-01 1.17234483e+00 1.23364964e+00 1.88737485 0.94752517 471.25 -2.89369413e-01 1.12386332e+00 1.16051860e+00 1.82280007 0.94403220 471.50 -1.40794288e-01 1.11747557e+00 1.12631020e+00 1.69612909 0.92772354 471.75 -1.23300555e-01 1.05568906e+00 1.06286519e+00 1.68706582 0.91427527 472.00 -6.18643098e-02 8.81135021e-01 8.83304091e-01 1.64089110 0.92855046 472.25 -2.78419843e-02 8.11428928e-01 8.11906448e-01 1.60509516 0.93063745 472.50 -1.21733911e-01 6.29367501e-01 6.41032446e-01 1.76185956 0.89334855 472.75 -2.25287534e-01 5.79987163e-01 6.22205418e-01 1.94129362 0.91071374 473.00 -3.55496496e-01 5.22741067e-01 6.32167685e-01 2.16801559 0.92342283 473.25 -4.32166282e-01 4.96025833e-01 6.57882454e-01 2.28750281 0.94149649 473.50 -5.55864969e-01 5.42413110e-01 7.76658127e-01 2.36844201 0.96824560 473.75 -6.05340297e-01 5.62263309e-01 8.26182125e-01 2.39307127 0.97290932 474.00 -6.68358184e-01 5.64013316e-01 8.74536267e-01 2.44066300 0.97605870 474.25 -6.93318635e-01 5.70160290e-01 8.97648866e-01 2.45336310 0.97805171 474.50 -7.35857016e-01 5.58693348e-01 9.23917640e-01 2.49220303 0.96770993 474.75 -7.90051039e-01 5.49924482e-01 9.62599387e-01 2.53351456 0.96371730 475.00 -9.02775149e-01 5.48635146e-01 1.05641066e+00 2.59551550 0.95628583 475.25 -9.93992631e-01 5.50282369e-01 1.13614789e+00 2.63598353 0.94402230 475.50 -1.21279623e+00 6.25570840e-01 1.36462947e+00 2.66537822 0.96142170 475.75 -1.31216258e+00 6.73460963e-01 1.47489671e+00 2.66740523 0.95452457 476.00 -1.51683864e+00 9.60911759e-01 1.79559206e+00 2.57690691 0.90801994 476.25 -1.52451095e+00 1.20505286e+00 1.94326685e+00 2.47270079 0.86847199 476.50 -1.25166458e+00 1.80791736e+00 2.19891551e+00 2.17635201 0.89979391 476.75 -1.05842366e+00 1.84807390e+00 2.12970368e+00 2.09091331 0.92227889 477.00 -6.92432270e-01 1.85599080e+00 1.98095035e+00 1.92788228 0.90680051 477.25 -6.19700267e-01 1.83425325e+00 1.93610780e+00 1.89660529 0.90746542 477.50 -5.52918699e-01 1.76850793e+00 1.85292725e+00 1.87381511 0.92439272 477.75 -3.71506981e-01 1.63004452e+00 1.67184407e+00 1.79488088 0.92047333 478.00 -2.74330173e-01 1.59466257e+00 1.61808706e+00 1.74115903 0.96017359 478.25 -2.27589302e-01 1.56487838e+00 1.58134159e+00 1.71521952 0.95928824 478.50 -1.99531795e-01 1.48690483e+00 1.50023295e+00 1.70419213 0.96182801 478.75 -1.89555562e-01 1.40447826e+00 1.41721222e+00 1.70495079 0.96783004 479.00 -2.04988066e-01 1.38362009e+00 1.39872251e+00 1.71787985 0.96961508 479.25 -3.05852376e-01 1.36220987e+00 1.39612371e+00 1.79166015 0.96588441 479.50 -3.66693040e-01 1.40484071e+00 1.45190950e+00 1.82612057 0.97049436 479.75 -3.37618380e-01 1.41679111e+00 1.45646257e+00 1.80473131 0.96322589 480.00 -3.01950268e-01 1.47115353e+00 1.50182112e+00 1.77323222 0.97412673 480.25 -3.05247103e-01 1.47721711e+00 1.50842507e+00 1.77456500 0.96010889 480.50 -3.60618760e-01 1.50707938e+00 1.54962387e+00 1.80566343 0.96511936 480.75 -3.72197765e-01 1.46700876e+00 1.51348798e+00 1.81926560 0.95592149 481.00 -3.36502650e-01 1.46878604e+00 1.50683989e+00 1.79601220 0.96334686 481.25 -2.83292977e-01 1.56343095e+00 1.58888994e+00 1.75005092 0.94749385 481.50 -1.99879257e-01 1.60768549e+00 1.62006307e+00 1.69448895 0.93337597 481.75 -7.50640273e-02 1.58745439e+00 1.58922813e+00 1.61804692 0.88221524 482.00 7.24975155e-03 1.45466265e+00 1.45468072e+00 1.56581257 0.84218814 482.25 -1.99016953e-01 1.13991410e+00 1.15715682e+00 1.74364360 0.75519860 482.50 -3.83735529e-01 9.82313939e-01 1.05460591e+00 1.94321168 0.77416379 482.75 -1.11100892e+00 9.32925278e-01 1.45075511e+00 2.44310289 0.73455071 483.00 -1.73991464e+00 9.89439821e-01 2.00157291e+00 2.62452744 0.73405774 483.25 -2.76571166e+00 1.94809755e+00 3.38293439e+00 2.52793663 0.73122856 483.50 -2.93234913e+00 3.08086460e+00 4.25328087e+00 2.33150132 0.72033272 483.75 -1.96622618e+00 4.39676150e+00 4.81638423e+00 1.99131828 0.69870110 484.00 -1.46797139e+00 4.10050091e+00 4.35534702e+00 1.91457853 0.45474398 484.25 3.17915047e+00 1.04037336e+00 3.34505223e+00 0.31626457 0.17167206 484.50 3.76663958e+00 -2.53412924e-01 3.77515454e+00 -0.06717702 0.29379429 484.75 2.05918252e+00 -7.95433318e-01 2.20747522e+00 -0.36862832 0.42491077 485.00 1.89554072e+00 -6.10447136e-02 1.89652342e+00 -0.03219325 0.49851759 485.25 1.94579714e+00 1.06940157e+00 2.22030318e+00 0.50253269 0.66985914 485.50 2.28728556e+00 1.35080268e+00 2.65637782e+00 0.53345697 0.70203504 485.75 3.68346448e+00 8.08497462e-01 3.77115085e+00 0.21606738 0.64964464 486.00 4.31851220e+00 -5.11392256e-01 4.34868597e+00 -0.11786970 0.65782553 486.25 3.57235772e+00 -2.46310325e+00 4.33919547e+00 -0.60363707 0.74710888 486.50 2.49306139e+00 -2.56237292e+00 3.57506784e+00 -0.79910761 0.71961111 486.75 1.47218233e+00 -2.59179389e+00 2.98072413e+00 -1.05422598 0.81226729 487.00 1.06467019e+00 -2.45135954e+00 2.67258044e+00 -1.16105958 0.83641242 487.25 4.21908422e-01 -2.27698279e+00 2.31574121e+00 -1.38758150 0.86430803 487.50 -6.94884371e-03 -2.23110663e+00 2.23111745e+00 -1.57391084 0.88976070 487.75 -3.94144485e-01 -2.01126703e+00 2.04952311e+00 -1.76431222 0.88820021 488.00 -6.00295662e-01 -1.57553925e+00 1.68602455e+00 -1.93482530 0.89693971 488.25 -6.40953791e-01 -1.27671543e+00 1.42857413e+00 -2.03606933 0.94895420 488.50 -6.49309813e-01 -1.01898064e+00 1.20827347e+00 -2.13813133 0.91929448 488.75 -6.81033819e-01 -7.29576985e-01 9.98042905e-01 -2.32179519 0.91454291 489.00 -5.99816488e-01 -5.82235318e-01 8.35929294e-01 -2.37106683 0.83317197 489.25 -4.70825049e-01 -5.35044262e-01 7.12705121e-01 -2.29243654 0.74923940 489.50 -4.44794963e-01 -5.92214335e-01 7.40648620e-01 -2.21498247 0.85044943 489.75 -4.87413197e-01 -6.30823400e-01 7.97188677e-01 -2.22864399 0.91243466 490.00 -5.87405905e-01 -5.84977172e-01 8.29001803e-01 -2.35826611 0.90689616 490.25 -6.30296848e-01 -4.84407666e-01 7.94937043e-01 -2.48633182 0.91339330 490.50 -6.56004136e-01 -4.31389084e-01 7.85135636e-01 -2.55989245 0.92895610 490.75 -7.03865458e-01 -4.05062449e-01 8.12097390e-01 -2.61939563 0.94089308 491.00 -7.59819281e-01 -3.35977263e-01 8.30786412e-01 -2.72526043 0.96312389 491.25 -7.87123853e-01 -2.88607540e-01 8.38366431e-01 -2.79015294 0.97333259 491.50 -8.02930311e-01 -1.91229007e-01 8.25388161e-01 -2.90778450 0.97008808 491.75 -8.19378317e-01 -1.39872368e-01 8.31231078e-01 -2.97251691 0.97654843 492.00 -8.23937619e-01 -5.67674531e-02 8.25890878e-01 -3.07280360 0.97576439 492.25 -8.12981891e-01 -3.07203334e-02 8.13562102e-01 -3.10382339 0.97851564 492.50 -8.45830322e-01 1.66350666e-02 8.45993888e-01 3.12192804 0.97644592 492.75 -8.51843640e-01 3.46602966e-02 8.52548487e-01 3.10092652 0.98532785 493.00 -8.32183169e-01 9.02003205e-02 8.37057301e-01 3.03362417 0.98196945 493.25 -8.41321171e-01 1.37650574e-01 8.52507474e-01 2.97941716 0.98378869 493.50 -8.42561111e-01 1.75566550e-01 8.60658376e-01 2.93615974 0.98554398 493.75 -8.23075959e-01 2.06957681e-01 8.48696363e-01 2.89525520 0.98504227 494.00 -8.25984881e-01 2.42017543e-01 8.60711052e-01 2.85656576 0.98194669 494.25 -8.38007666e-01 2.78072340e-01 8.82938885e-01 2.82119973 0.98137856 494.50 -7.96679468e-01 3.36153957e-01 8.64695124e-01 2.74231349 0.98333247 494.75 -7.74455753e-01 3.60483133e-01 8.54242238e-01 2.70595157 0.98285188 495.00 -7.48144147e-01 4.18034041e-01 8.57013491e-01 2.63204777 0.98246774 495.25 -7.22547120e-01 4.55506431e-01 8.54143108e-01 2.57910701 0.97752049 495.50 -6.39393046e-01 4.86112552e-01 8.03199153e-01 2.49154989 0.97813054 495.75 -6.20688593e-01 4.81483662e-01 7.85544936e-01 2.48182979 0.97046810 496.00 -5.65016040e-01 4.51009765e-01 7.22947393e-01 2.46793514 0.94905581 496.25 -5.20161087e-01 4.48452468e-01 6.86787575e-01 2.43009191 0.94857600 496.50 -4.31777332e-01 4.03254471e-01 5.90801010e-01 2.39033903 0.94831266 496.75 -4.19857340e-01 3.44325253e-01 5.42991773e-01 2.45471486 0.93258955 497.00 -4.20789333e-01 2.37500194e-01 4.83187339e-01 2.62774898 0.90948886 497.25 -4.31911022e-01 1.91493931e-01 4.72458524e-01 2.72427066 0.91712612 497.50 -4.40438480e-01 1.17457115e-01 4.55831360e-01 2.88097573 0.91958400 497.75 -4.63617144e-01 7.80497159e-02 4.70141058e-01 2.97480707 0.92245498 498.00 -5.24931531e-01 2.88846756e-02 5.25725629e-01 3.08662248 0.93903588 498.25 -5.97426205e-01 -8.78552453e-03 5.97490799e-01 -3.12688809 0.92370069 498.50 -6.86051434e-01 -6.36536358e-02 6.88998081e-01 -3.04907493 0.94892716 498.75 -7.50474986e-01 -1.00936152e-01 7.57232337e-01 -3.00789859 0.93514981 499.00 -8.46210924e-01 -9.83229383e-02 8.51903943e-01 -3.02591935 0.94655977 499.25 -8.70891913e-01 -9.90779523e-02 8.76509649e-01 -3.02831362 0.94652222 499.50 -9.23262851e-01 -8.69915830e-02 9.27352051e-01 -3.04764810 0.94168689 499.75 -9.89418236e-01 -9.47804081e-02 9.93947569e-01 -3.04608999 0.93341145 500.00 -1.03726540e+00 -9.19602092e-02 1.04133385e+00 -3.05316745 0.94107095 500.25 -1.07758336e+00 -1.15637158e-01 1.08377021e+00 -3.03469019 0.94863130 500.50 -1.08701512e+00 -1.24116331e-01 1.09407803e+00 -3.02790414 0.96052236 500.75 -1.13043649e+00 -1.39379341e-01 1.13899660e+00 -3.01891488 0.94379904 501.00 -1.18398842e+00 -1.96353558e-01 1.20015970e+00 -2.97724765 0.94702151 501.25 -1.25668707e+00 -2.51618484e-01 1.28162953e+00 -2.94398205 0.93134996 501.50 -1.35109629e+00 -2.75371103e-01 1.37887289e+00 -2.94053337 0.94949555 501.75 -1.44864569e+00 -3.14996119e-01 1.48249684e+00 -2.92748376 0.95718861 502.00 -1.47774970e+00 -3.30938596e-01 1.51435284e+00 -2.92128006 0.94523425 502.25 -1.59470264e+00 -5.31895430e-01 1.68106789e+00 -2.81965706 0.93025412 502.50 -1.73921282e+00 -6.27342557e-01 1.84889694e+00 -2.79541320 0.94801328 502.75 -2.08302977e+00 -7.03810339e-01 2.19871826e+00 -2.81575732 0.93705066 503.00 -2.35001181e+00 -7.33235456e-01 2.46174526e+00 -2.83915105 0.96259722 503.25 -2.60105565e+00 -5.73588496e-01 2.66354919e+00 -2.92454505 0.95701511 503.50 -2.78081002e+00 -4.62847190e-01 2.81906578e+00 -2.97666132 0.95952144 503.75 -2.99287505e+00 -2.75336071e-01 3.00551344e+00 -3.04985370 0.94603109 504.00 -3.04768532e+00 -2.58329435e-01 3.05861405e+00 -3.05703228 0.95143486 504.25 -2.99190608e+00 -2.11429937e-01 2.99936737e+00 -3.07104263 0.97148395 504.50 -3.05382402e+00 -2.41601829e-01 3.06336621e+00 -3.06264258 0.96329574 504.75 -3.39723475e+00 -4.49872387e-01 3.42689205e+00 -3.00993555 0.92659748 505.00 -3.56818531e+00 -5.27306748e-01 3.60693760e+00 -2.99487447 0.92334027 505.25 -3.97212454e+00 -6.74047329e-01 4.02890968e+00 -2.97349952 0.90332069 505.50 -4.21483834e+00 -9.12498268e-01 4.31248366e+00 -2.92838644 0.89864092 505.75 -4.37509133e+00 -5.67461478e-01 4.41173850e+00 -3.01260995 0.87638959 506.00 -4.50517837e+00 -2.92238545e-01 4.51464678e+00 -3.07681615 0.84694797 506.25 -3.95650808e+00 1.75930219e-01 3.96041761e+00 3.09715589 0.78813113 506.50 -3.40446737e+00 -6.92890622e-02 3.40517239e+00 -3.12124307 0.77410797 506.75 -2.73530595e+00 -6.32455692e-01 2.80747197e+00 -2.91436648 0.77796575 507.00 -2.37428442e+00 -1.28527339e+00 2.69984336e+00 -2.64542958 0.75013552 507.25 -1.76142166e+00 -2.45392614e+00 3.02065552e+00 -2.19336722 0.76970739 507.50 -1.23886910e+00 -2.97389385e+00 3.22162091e+00 -1.96551486 0.72100437 507.75 -5.13274784e-01 -3.60899185e+00 3.64530838e+00 -1.71207000 0.71605138 508.00 -1.62498192e-01 -3.47562126e+00 3.47941789e+00 -1.61751602 0.71353003 508.25 2.70246153e-01 -3.12579965e+00 3.13746019e+00 -1.48455413 0.74258518 508.50 5.78398519e-01 -2.94698160e+00 3.00320585e+00 -1.37699168 0.74278284 508.75 1.28162305e+00 -2.59092784e+00 2.89058207e+00 -1.11143149 0.77039368 509.00 1.63092916e+00 -2.08732647e+00 2.64893596e+00 -0.90753224 0.75559022 509.25 1.83320369e+00 -1.27016490e+00 2.23023645e+00 -0.60592213 0.71142530 509.50 2.07617380e+00 -8.60216272e-01 2.24732501e+00 -0.39279648 0.71035149 509.75 2.37861384e+00 -6.86325334e-01 2.47565068e+00 -0.28091019 0.77870497 510.00 2.38895573e+00 -3.58539302e-01 2.41571106e+00 -0.14897016 0.77921408 510.25 2.16520425e+00 2.72608003e-01 2.18229800e+00 0.12524505 0.75379896 510.50 1.88088468e+00 5.06976769e-01 1.94801248e+00 0.26328458 0.68526000 510.75 1.44244871e+00 7.67287296e-01 1.63382621e+00 0.48886713 0.63329998 511.00 8.78627300e-01 8.75523825e-01 1.24037410e+00 0.78362895 0.38355092 511.25 5.71498841e-01 8.55198723e-01 1.02857950e+00 0.98168843 0.25568147 511.50 6.62116009e-01 7.55625395e-01 1.00467276e+00 0.85125936 0.17009214 511.75 7.27559575e-01 1.09181221e+00 1.31202014e+00 0.98299364 0.23250156 512.00 3.92534314e-02 1.15659959e+00 1.15726550e+00 1.53687070 0.14534835 512.25 -2.21046294e-01 6.35080410e-01 6.72449694e-01 1.90574211 0.04998817 512.50 -3.03849985e-01 9.78004937e-01 1.02411839e+00 1.87202544 0.08689338 512.75 -7.16963318e-01 1.27647246e+00 1.46404179e+00 2.08255925 0.15107012 513.00 -1.05757814e+00 1.35286136e+00 1.71717948e+00 2.23430000 0.26531289 513.25 -1.16470677e+00 1.59542004e+00 1.97532452e+00 2.20139459 0.28690028 513.50 -8.27487831e-01 1.37959571e+00 1.60873255e+00 2.11107213 0.23156799 513.75 -8.74483321e-01 1.30472483e+00 1.57067755e+00 2.16127111 0.26031813 514.00 -7.99413560e-01 1.81119603e+00 1.97977097e+00 1.98645317 0.66207363 514.25 -9.07064993e-01 1.57856783e+00 1.82061619e+00 2.09233943 0.71397634 514.50 -9.15099408e-01 1.08820681e+00 1.42183015e+00 2.26999775 0.72427938 514.75 -8.55313013e-01 1.04324519e+00 1.34904443e+00 2.25752912 0.83664861 515.00 -7.51202503e-01 8.26365265e-01 1.11677426e+00 2.30858578 0.85386000 515.25 -6.63747204e-01 6.69397511e-01 9.42684136e-01 2.35195619 0.86164295 515.50 -5.12023832e-01 4.92281768e-01 7.10288493e-01 2.37584939 0.89424121 515.75 -4.60186132e-01 4.10096879e-01 6.16401433e-01 2.41368620 0.89481528 516.00 -3.66208683e-01 2.51860117e-01 4.44457330e-01 2.53913539 0.88484606 516.25 -3.54625648e-01 1.96930728e-01 4.05636613e-01 2.63467414 0.88351588 516.50 -3.43229469e-01 1.30150916e-01 3.67077280e-01 2.77914921 0.88252568 516.75 -3.27715321e-01 1.10358445e-01 3.45798089e-01 2.81676941 0.88739649 517.00 -2.89051073e-01 6.11313605e-02 2.95444692e-01 2.93317399 0.84966420 517.25 -2.75526445e-01 4.50679679e-02 2.79188007e-01 2.97945807 0.81942166 517.50 -2.41271265e-01 1.56206824e-02 2.41776403e-01 3.07693965 0.80228053 517.75 -2.26680268e-01 -5.49892527e-03 2.26746956e-01 -3.11733890 0.75800567 518.00 -2.09023589e-01 -3.40126128e-02 2.11772799e-01 -2.98028504 0.73919673 518.25 -2.07820003e-01 -6.30787529e-02 2.17182142e-01 -2.84690424 0.67652345 518.50 -2.36535119e-01 -8.32321320e-02 2.50751770e-01 -2.80324340 0.71035913 518.75 -2.39925334e-01 -4.79058227e-02 2.44661264e-01 -2.94451470 0.61791486 519.00 -2.32096492e-01 -6.44637348e-03 2.32185997e-01 -3.11382525 0.69505758 519.25 -2.21972528e-01 1.47225735e-02 2.22460238e-01 3.07536355 0.71420489 519.50 -2.07944113e-01 5.53208054e-02 2.15177010e-01 2.88157832 0.70374061 519.75 -1.85937334e-01 4.53608391e-02 1.91390433e-01 2.90230892 0.59326220 520.00 -1.61854945e-01 2.91201205e-02 1.64453655e-01 2.96358212 0.58079047 520.25 -1.61769942e-01 2.21204692e-02 1.63275317e-01 3.00569518 0.62215604 520.50 -1.81257562e-01 4.29998697e-03 1.81308559e-01 3.11787403 0.72126368 520.75 -2.05024215e-01 3.21134417e-02 2.07523979e-01 2.98622261 0.72574744 521.00 -2.52302870e-01 8.10553521e-02 2.65003223e-01 2.83074525 0.79463118 521.25 -2.52848194e-01 1.84719125e-01 3.13134738e-01 2.51065393 0.79717820 521.50 -1.66388310e-01 2.70965907e-01 3.17974201e-01 2.12148725 0.82028628 521.75 -2.34925002e-02 3.03319502e-01 3.04227904e-01 1.64809335 0.72521375 522.00 1.00714083e-01 3.11657013e-01 3.27526214e-01 1.25823244 0.80987821 522.25 2.36912523e-01 2.15159438e-01 3.20033010e-01 0.73731661 0.70736377 522.50 2.96830773e-01 8.68916610e-02 3.09287356e-01 0.28477500 0.74188886 522.75 2.94373286e-01 -4.45525034e-02 2.97725640e-01 -0.15020701 0.81103787 523.00 2.72175528e-01 -9.35216699e-02 2.87794754e-01 -0.33096902 0.86649031 523.25 2.26943421e-01 -1.67810356e-01 2.82247466e-01 -0.63670642 0.77566395 523.50 1.93061643e-01 -2.15363124e-01 2.89230139e-01 -0.83994764 0.81797285 523.75 1.01506975e-01 -2.14418462e-01 2.37231833e-01 -1.12864940 0.73559785 524.00 4.57769747e-02 -2.12579847e-01 2.17452806e-01 -1.35869507 0.78893120 524.25 2.82727522e-02 -2.08423415e-01 2.10332281e-01 -1.43596874 0.78706888 524.50 2.55729622e-02 -2.10329455e-01 2.11878399e-01 -1.44980494 0.79308776 524.75 2.71973579e-02 -2.23901963e-01 2.25547745e-01 -1.44991858 0.79005547 525.00 4.11614912e-03 -2.49444199e-01 2.49478158e-01 -1.55429654 0.83090430 525.25 -4.66231521e-02 -3.18817078e-01 3.22208081e-01 -1.71600498 0.85267159 525.50 -8.41935501e-02 -3.37361545e-01 3.47708737e-01 -1.81536530 0.87347437 525.75 -1.35335108e-01 -3.55505333e-01 3.80394049e-01 -1.93454069 0.85109171 526.00 -2.02278812e-01 -3.42638859e-01 3.97892078e-01 -2.10409427 0.83716792 526.25 -2.82107527e-01 -2.91743381e-01 4.05831070e-01 -2.33940450 0.90575760 526.50 -3.11858151e-01 -2.45077534e-01 3.96633967e-01 -2.47553196 0.90919620 526.75 -3.69950861e-01 -1.95521483e-01 4.18440307e-01 -2.65540067 0.93219407 527.00 -3.88403065e-01 -1.69083874e-01 4.23611021e-01 -2.73100424 0.94074960 527.25 -3.93511197e-01 -1.01285292e-01 4.06337018e-01 -2.88967220 0.95403080 527.50 -3.98060307e-01 -6.24210287e-02 4.02924798e-01 -2.98604638 0.96353199 527.75 -3.88585864e-01 -2.97466897e-02 3.89722772e-01 -3.06519052 0.97180570 528.00 -3.82059777e-01 -7.26518738e-03 3.82128848e-01 -3.12257911 0.97101622 528.25 -3.59041699e-01 2.99982526e-02 3.60292710e-01 3.05823537 0.97250522 528.50 -3.40658842e-01 4.09267318e-02 3.43108501e-01 3.02202578 0.96951829 528.75 -3.27614676e-01 5.42261296e-02 3.32072054e-01 2.97756179 0.97640398 529.00 -3.24916176e-01 5.80150916e-02 3.30054954e-01 2.96490066 0.97530726 529.25 -3.37067970e-01 4.63823951e-02 3.40244240e-01 3.00484598 0.96840011 529.50 -3.75406999e-01 6.11867849e-02 3.80360668e-01 2.98002547 0.95287106 529.75 -3.92233476e-01 1.17655931e-01 4.09499717e-01 2.85016887 0.97703738 530.00 -3.69907100e-01 1.43151425e-01 3.96640383e-01 2.77234933 0.97547573 530.25 -3.55079883e-01 1.68706016e-01 3.93120138e-01 2.69804535 0.98404350 530.50 -3.44029065e-01 1.89401349e-01 3.92719835e-01 2.63833587 0.98002750 530.75 -3.30153605e-01 2.11981001e-01 3.92348502e-01 2.57081389 0.98258602 531.00 -3.14986720e-01 2.18199811e-01 3.83181147e-01 2.53576458 0.98026432 531.25 -3.08164821e-01 2.34859689e-01 3.87459198e-01 2.49037747 0.98414474 531.50 -2.94755373e-01 2.44847471e-01 3.83185352e-01 2.44842217 0.97856993 531.75 -2.90044857e-01 2.51905186e-01 3.84164342e-01 2.42645354 0.96928767 532.00 -2.87671905e-01 2.52998914e-01 3.83097345e-01 2.42023637 0.96614800 532.25 -2.80170481e-01 2.45409435e-01 3.72453070e-01 2.42223677 0.96454705 532.50 -2.96208155e-01 2.45460076e-01 3.84694581e-01 2.44961030 0.96382912 532.75 -3.17445840e-01 2.50322447e-01 4.04268709e-01 2.47387149 0.97168512 533.00 -3.55046772e-01 2.65150037e-01 4.43128370e-01 2.50014069 0.96808270 533.25 -3.59680024e-01 2.88111743e-01 4.60844980e-01 2.46622863 0.96433687 533.50 -3.72135697e-01 3.71887480e-01 5.26103863e-01 2.35652811 0.95804886 533.75 -3.90246599e-01 4.21515290e-01 5.74428018e-01 2.31769399 0.96345075 534.00 -3.61371916e-01 5.42352065e-01 6.51717289e-01 2.15854853 0.96046883 534.25 -3.20479451e-01 5.97741736e-01 6.78234665e-01 2.06294428 0.95896000 534.50 -1.77223727e-01 6.93295236e-01 7.15588244e-01 1.82106224 0.93316556 534.75 -1.27243176e-01 7.39704959e-01 7.50569285e-01 1.74114794 0.94548384 535.00 2.05454042e-02 7.32526139e-01 7.32814204e-01 1.54275635 0.92311454 535.25 1.13475007e-01 7.01732381e-01 7.10848023e-01 1.41047716 0.94161380 535.50 1.90797882e-01 6.26031065e-01 6.54460638e-01 1.27496565 0.91595750 535.75 2.46801317e-01 5.68654183e-01 6.19901984e-01 1.16131937 0.90055557 536.00 3.00389339e-01 4.13029774e-01 5.10712590e-01 0.94199363 0.87494812 536.25 2.89176791e-01 3.39202286e-01 4.45736926e-01 0.86484099 0.86182205 536.50 2.41452990e-01 2.26180316e-01 3.30842987e-01 0.75275026 0.80600165 536.75 2.05701189e-01 1.94961341e-01 2.83412956e-01 0.75859936 0.76509758 537.00 1.35427063e-01 1.80537481e-01 2.25686223e-01 0.92721031 0.68782662 537.25 1.15186795e-01 1.71889382e-01 2.06915339e-01 0.98040563 0.64832069 537.50 6.84088564e-02 1.13099921e-01 1.32179286e-01 1.02681589 0.35966074 537.75 1.78439526e-02 1.11211196e-01 1.12633640e-01 1.41170131 0.18740921 538.00 1.87508341e-03 1.84454309e-01 1.84463840e-01 1.56063111 0.19201231 538.25 -2.88255321e-02 2.44868861e-01 2.46559669e-01 1.68797528 0.23660671 538.50 5.33571300e-02 2.32898837e-01 2.38932735e-01 1.34558286 0.19732605 538.75 5.41709316e-02 2.46524348e-01 2.52405911e-01 1.35449530 0.24642926 539.00 1.37223749e-01 2.34265742e-01 2.71497321e-01 1.04091243 0.38454589 539.25 2.06754081e-01 1.82851191e-01 2.76010522e-01 0.72412341 0.50846231 539.50 2.31958733e-01 1.38578739e-01 2.70201629e-01 0.53852649 0.62501606 539.75 1.99706396e-01 1.49793863e-01 2.49641435e-01 0.64354619 0.54836019 540.00 1.54859082e-01 1.73358517e-01 2.32453244e-01 0.84170192 0.67243630 540.25 1.35576556e-01 1.60477177e-01 2.10080763e-01 0.86930912 0.62481884 540.50 1.36632916e-01 1.58390373e-01 2.09179502e-01 0.85901317 0.66814552 540.75 1.52391208e-01 1.71842755e-01 2.29680240e-01 0.84531866 0.71517313 541.00 1.75506146e-01 1.69462303e-01 2.43966964e-01 0.76787997 0.80145758 541.25 1.80710672e-01 1.52132759e-01 2.36221767e-01 0.69974829 0.77541610 541.50 1.75130010e-01 1.38285112e-01 2.23144107e-01 0.66837587 0.77679118 541.75 1.72718144e-01 1.31123955e-01 2.16852597e-01 0.64934971 0.73348562 542.00 1.67588579e-01 8.95815206e-02 1.90028368e-01 0.49089037 0.64727679 542.25 1.29477180e-01 7.82964634e-02 1.51309868e-01 0.54387734 0.52192141 542.50 1.10755070e-01 1.16377064e-01 1.60655864e-01 0.81014520 0.52169175 542.75 9.27501686e-02 2.15352613e-01 2.34476741e-01 1.16411628 0.56721773 543.00 1.48152640e-01 2.58395039e-01 2.97854329e-01 1.05019758 0.61504539 543.25 2.65268217e-01 1.65704847e-01 3.12770401e-01 0.55836130 0.72523517 543.50 2.53250921e-01 1.11446378e-01 2.76688135e-01 0.41455971 0.72800957 543.75 2.68598056e-01 1.43693070e-01 3.04618801e-01 0.49123406 0.76538224 544.00 2.93311472e-01 1.36470843e-01 3.23505657e-01 0.43548473 0.84661356 544.25 3.27829686e-01 8.91747879e-02 3.39741734e-01 0.26558952 0.82881213 544.50 3.28172504e-01 5.51488423e-02 3.32774078e-01 0.16649270 0.82480879 544.75 3.00068935e-01 -1.12508075e-02 3.00279781e-01 -0.03747652 0.88183267 545.00 2.77997145e-01 -2.58528347e-02 2.79196672e-01 -0.09273006 0.87688052 545.25 2.61121527e-01 -5.97974205e-02 2.67880913e-01 -0.22512057 0.83546568 545.50 2.63372280e-01 -5.67538863e-02 2.69417819e-01 -0.21224371 0.81694614 545.75 2.73520518e-01 -6.54518708e-02 2.81242637e-01 -0.23487750 0.79396450 546.00 2.59133872e-01 -7.35731042e-02 2.69375881e-01 -0.27663935 0.75871219 546.25 2.99412617e-01 -1.21544921e-01 3.23142512e-01 -0.38562046 0.77153106 546.50 3.12487898e-01 -1.53196529e-01 3.48019918e-01 -0.45581552 0.79584268 546.75 2.94348900e-01 -1.99265667e-01 3.55454752e-01 -0.59510248 0.78457031 547.00 2.64317278e-01 -2.34979191e-01 3.53664875e-01 -0.72670680 0.79137089 547.25 1.86353732e-01 -2.82679927e-01 3.38578875e-01 -0.98795335 0.82557627 547.50 1.72962204e-01 -2.50004778e-01 3.04003805e-01 -0.96557087 0.76385486 547.75 1.59603562e-01 -2.78898759e-01 3.21337540e-01 -1.05102108 0.77707493 548.00 1.75285374e-01 -2.93763636e-01 3.42084838e-01 -1.03281533 0.76743088 548.25 2.05221534e-01 -2.66673131e-01 3.36497306e-01 -0.91489258 0.65546472 548.50 2.24837785e-01 -3.34037575e-01 4.02657585e-01 -0.97835908 0.62152656 548.75 2.67296224e-01 -5.77340749e-01 6.36215068e-01 -1.13720223 0.63728471 549.00 1.85113059e-02 -6.32857510e-01 6.33128184e-01 -1.54155431 0.53580496 549.25 -3.18910314e-01 -7.33406323e-01 7.99742848e-01 -1.98096724 0.70610291 549.50 -4.85894236e-01 -5.91792263e-01 7.65709665e-01 -2.25824472 0.65220267 549.75 -6.75001537e-01 -4.33982295e-01 8.02475986e-01 -2.57019989 0.66011737 550.00 -6.75023414e-01 -2.92055840e-01 7.35495223e-01 -2.73325159 0.77358182 550.25 -6.53780153e-01 -1.57767218e-01 6.72546640e-01 -2.90480429 0.88140407 550.50 -5.62788310e-01 -1.12774157e-01 5.73976212e-01 -2.94382723 0.84558654 550.75 -5.11740697e-01 -1.25190411e-01 5.26831263e-01 -2.90166840 0.88607195 551.00 -5.06120298e-01 -9.13198125e-02 5.14292781e-01 -2.96308223 0.85548267 551.25 -5.00878151e-01 -6.04969988e-02 5.04518393e-01 -3.02139303 0.85708547 551.50 -4.66826603e-01 -6.22860702e-02 4.70963514e-01 -3.00895162 0.82234482 551.75 -4.33886959e-01 -3.56987213e-02 4.35353066e-01 -3.05950101 0.81976049 552.00 -4.36369079e-01 -2.56576698e-02 4.37122739e-01 -3.08286218 0.82954771 552.25 -4.82927366e-01 -2.85372631e-02 4.83769796e-01 -3.08256904 0.86288032 552.50 -4.69901781e-01 -1.78449407e-02 4.70240497e-01 -3.10363500 0.89512342 552.75 -4.47796693e-01 2.70058637e-03 4.47804837e-01 3.13556190 0.89424140 553.00 -4.41610560e-01 5.56334032e-02 4.45101070e-01 3.01627440 0.89615662 553.25 -4.28158919e-01 6.37630920e-02 4.32880805e-01 2.99375530 0.88328186 553.50 -4.36285157e-01 3.56201308e-02 4.37736829e-01 3.06012919 0.91914332 553.75 -4.54385339e-01 2.38444392e-02 4.55010542e-01 3.08916449 0.94460751 554.00 -4.95151884e-01 3.09150348e-03 4.95161535e-01 3.13534919 0.94858286 554.25 -5.21958030e-01 -1.81112414e-02 5.22272153e-01 -3.10690791 0.96345784 554.50 -5.69932342e-01 4.82281812e-03 5.69952747e-01 3.13313077 0.95061880 554.75 -5.99414607e-01 3.42816196e-02 6.00394121e-01 3.08446306 0.95213907 555.00 -6.18468101e-01 7.10697650e-02 6.22538114e-01 3.02718191 0.96069094 555.25 -6.21180694e-01 1.02652282e-01 6.29605389e-01 2.97781927 0.96507450 555.50 -6.80716627e-01 1.59152072e-01 6.99074036e-01 2.91191746 0.94465766 555.75 -7.20631088e-01 2.07127051e-01 7.49807162e-01 2.86171254 0.95480762 556.00 -7.18170393e-01 3.02394557e-01 7.79237565e-01 2.74306190 0.94158631 556.25 -7.14917047e-01 3.53902059e-01 7.97717401e-01 2.68193268 0.92655456 556.50 -6.60268482e-01 4.83634629e-01 8.18447874e-01 2.50939780 0.90941314 556.75 -6.31555948e-01 5.36901779e-01 8.28930900e-01 2.43702577 0.89079047 557.00 -5.59190927e-01 6.23048836e-01 8.37188357e-01 2.30223258 0.90132469 557.25 -5.25747916e-01 6.32110865e-01 8.22176999e-01 2.26458982 0.92637225 557.50 -4.59203253e-01 6.84187721e-01 8.24002709e-01 2.16190710 0.92647493 557.75 -4.28727777e-01 6.87933506e-01 8.10592386e-01 2.12810819 0.91720839 558.00 -2.93821683e-01 6.36571539e-01 7.01109481e-01 2.00322927 0.91005108 558.25 -2.58420899e-01 6.39501722e-01 6.89741846e-01 1.95482983 0.90292259 558.50 -1.96219223e-01 6.05163243e-01 6.36179640e-01 1.88434231 0.90939362 558.75 -1.89560056e-01 5.93897943e-01 6.23416219e-01 1.87975482 0.90820022 559.00 -1.64414361e-01 5.84900964e-01 6.07569930e-01 1.84482271 0.90559306 559.25 -1.47477170e-01 5.67009435e-01 5.85874743e-01 1.82525477 0.88904507 559.50 -1.21260747e-01 6.01050279e-01 6.13160343e-01 1.76987218 0.87086942 559.75 -1.21819654e-01 6.03414585e-01 6.15588490e-01 1.77000261 0.87214566 560.00 -1.14150062e-01 5.75250494e-01 5.86466851e-01 1.76668701 0.85160089 560.25 -1.32633727e-01 5.30202499e-01 5.46540388e-01 1.81592250 0.77543908 560.50 -2.01277437e-01 5.10449604e-01 5.48699740e-01 1.94639141 0.76561783 560.75 -1.87382036e-01 5.13607633e-01 5.46721893e-01 1.92062556 0.73995648 561.00 -1.23410790e-01 5.67612417e-01 5.80873548e-01 1.78488525 0.75732860 561.25 -8.81979927e-02 5.55104090e-01 5.62067110e-01 1.72836472 0.70295778 561.50 -4.40677779e-02 6.60689765e-01 6.62157787e-01 1.63739733 0.69622116 561.75 1.15465372e-02 6.61254647e-01 6.61355450e-01 1.55333654 0.64963109 562.00 1.36053145e-01 6.15612670e-01 6.30467618e-01 1.35328814 0.57675390 562.25 2.47747760e-01 5.24063070e-01 5.79673231e-01 1.12919016 0.54677447 562.50 2.59595969e-01 4.08335190e-01 4.83867434e-01 1.00450945 0.61413919 562.75 2.51415605e-01 3.24874566e-01 4.10795923e-01 0.91218314 0.58982718 563.00 2.43299635e-01 2.74153384e-01 3.66544390e-01 0.84495384 0.61175703 563.25 1.92097907e-01 2.18362494e-01 2.90832915e-01 0.84929916 0.60725939 563.50 1.88599886e-01 1.93911301e-01 2.70502329e-01 0.79928292 0.68431497 563.75 1.42689706e-01 1.72473668e-01 2.23847087e-01 0.87962157 0.53120112 564.00 1.44847249e-01 1.67577158e-01 2.21501308e-01 0.85802352 0.58930364 564.25 1.34098570e-01 1.61251891e-01 2.09725055e-01 0.87707638 0.51912617 564.50 9.65677762e-02 1.45727755e-01 1.74819661e-01 0.98557355 0.46712413 564.75 8.38082403e-02 1.69909769e-01 1.89454877e-01 1.11256212 0.58190153 565.00 8.09031826e-02 1.75798976e-01 1.93521587e-01 1.13949021 0.64699281 565.25 1.05789748e-01 1.75997615e-01 2.05345152e-01 1.02957849 0.67328077 565.50 1.28420955e-01 1.54787150e-01 2.01124348e-01 0.87822889 0.67288444 565.75 1.10959737e-01 4.38638391e-02 1.19315127e-01 0.37645944 0.32012910 566.00 9.35063374e-02 4.32609130e-03 9.36063577e-02 0.04623225 0.23679360 566.25 6.14358773e-02 -1.15837283e-01 1.31120719e-01 -1.08315393 0.32196427 566.50 3.44361185e-02 -1.50607942e-01 1.54494655e-01 -1.34601293 0.33545143 566.75 -1.97239396e-01 -2.16270443e-01 2.92705114e-01 -2.31020374 0.65327928 567.00 -2.56167724e-01 -2.18962462e-01 3.36996235e-01 -2.43434043 0.76302731 567.25 -4.59724950e-01 -1.80602988e-01 4.93927595e-01 -2.76726515 0.86582741 567.50 -5.43298112e-01 -1.30420049e-01 5.58732698e-01 -2.90599807 0.87109664 567.75 -6.77722852e-01 -1.34706537e-02 6.77856713e-01 -3.12171892 0.91814940 568.00 -7.17746933e-01 6.55350828e-02 7.20732618e-01 3.05053846 0.94428227 568.25 -7.59210322e-01 2.12664817e-01 7.88433027e-01 2.86847900 0.96424800 568.50 -7.88519692e-01 2.82858626e-01 8.37718513e-01 2.79716973 0.96183300 568.75 -8.00761155e-01 3.42785221e-01 8.71045427e-01 2.73712098 0.95551216 569.00 -8.25323440e-01 4.04152206e-01 9.18965607e-01 2.68622743 0.95747266 569.25 -8.64052232e-01 4.93623395e-01 9.95113218e-01 2.62255188 0.97005863 569.50 -8.95067193e-01 5.33085185e-01 1.04178937e+00 2.60442861 0.96409816 569.75 -9.64292763e-01 6.64133004e-01 1.17086856e+00 2.53847362 0.96441178 570.00 -9.71943436e-01 7.88244015e-01 1.25140028e+00 2.46018160 0.95113055 570.25 -9.34568618e-01 1.01829569e+00 1.38215217e+00 2.31334675 0.95342530 570.50 -8.53629227e-01 1.12522670e+00 1.41238025e+00 2.21979695 0.95337334 570.75 -6.32600443e-01 1.26004187e+00 1.40992511e+00 2.03608032 0.93459991 571.00 -5.04142217e-01 1.26502357e+00 1.36177972e+00 1.95002962 0.91703614 571.25 -4.55827704e-01 1.25003160e+00 1.33054796e+00 1.92046489 0.91333146 571.50 -4.28807609e-01 1.25418418e+00 1.32546367e+00 1.90023842 0.87245304 571.75 -4.11297595e-01 1.32572027e+00 1.38805618e+00 1.87162516 0.89875239 572.00 -4.65348329e-01 1.38147646e+00 1.45774699e+00 1.89570722 0.91697767 572.25 -4.81238861e-01 1.45448877e+00 1.53203408e+00 1.89032339 0.90993946 572.50 -5.25874110e-01 1.56775960e+00 1.65360628e+00 1.89443298 0.90923895 572.75 -4.60129915e-01 1.69355881e+00 1.75495327e+00 1.83608647 0.91626093 573.00 -1.72041497e-01 2.00596776e+00 2.01333180e+00 1.65635180 0.90293905 573.25 3.98760990e-02 2.20827368e+00 2.20863368e+00 1.55274070 0.92585502 573.50 3.01173735e-01 2.10896570e+00 2.13036193e+00 1.42894903 0.91115994 573.75 3.60329985e-01 2.20660574e+00 2.23583242e+00 1.40892896 0.91351507 574.00 4.63709783e-01 2.28737483e+00 2.33390453e+00 1.37078123 0.89678918 574.25 6.56164264e-01 2.42679172e+00 2.51393508e+00 1.30672715 0.90942882 574.50 9.60476480e-01 2.45072030e+00 2.63221296e+00 1.19727829 0.88158312 574.75 1.40322346e+00 2.41531833e+00 2.79334902e+00 1.04448826 0.88395657 575.00 1.77179092e+00 2.48171988e+00 3.04929117e+00 0.95077798 0.89494959 575.25 2.06026179e+00 2.42704890e+00 3.18358995e+00 0.86695559 0.92285274 575.50 2.30723768e+00 2.10365308e+00 3.12229115e+00 0.73927591 0.88791089 575.75 2.72618039e+00 1.90047034e+00 3.32322840e+00 0.60878934 0.89025812 576.00 3.04878831e+00 1.34601460e+00 3.33269642e+00 0.41575590 0.84028499 576.25 3.33644773e+00 9.66327286e-01 3.47356761e+00 0.28191386 0.84547842 576.50 3.74765382e+00 2.83651353e-01 3.75837295e+00 0.07554368 0.81146298 576.75 3.73372452e+00 -5.62813484e-01 3.77590490e+00 -0.14961145 0.82901936 577.00 2.88807144e+00 -1.65905296e+00 3.33067761e+00 -0.52142092 0.76564248 577.25 2.10800374e+00 -2.05331382e+00 2.94274997e+00 -0.77225647 0.77593505 577.50 1.35461698e+00 -1.85076836e+00 2.29354108e+00 -0.93896627 0.77855130 577.75 8.56355438e-01 -1.70899172e+00 1.91154319e+00 -1.10627861 0.79612042 578.00 5.30644195e-01 -1.44440724e+00 1.53879678e+00 -1.21872419 0.88423172 578.25 4.63182463e-01 -1.29443172e+00 1.37480598e+00 -1.22716587 0.91379595 578.50 3.96094497e-01 -1.02321322e+00 1.09720379e+00 -1.20145250 0.93007871 578.75 3.53234541e-01 -9.28869887e-01 9.93767533e-01 -1.20740100 0.92257485 579.00 3.25495023e-01 -7.64464025e-01 8.30874393e-01 -1.16826350 0.89679931 579.25 2.95640477e-01 -6.61091054e-01 7.24185524e-01 -1.15027262 0.89524843 579.50 2.97120043e-01 -5.43323294e-01 6.19258041e-01 -1.07036952 0.91785619 579.75 2.99734403e-01 -4.76643332e-01 5.63053797e-01 -1.00943740 0.90304234 580.00 2.95367551e-01 -3.62395127e-01 4.67517078e-01 -0.88694999 0.90932903 580.25 3.15771082e-01 -3.19683432e-01 4.49342712e-01 -0.79155486 0.88599902 580.50 3.81783133e-01 -2.37649381e-01 4.49706114e-01 -0.55677950 0.91313886 580.75 3.98971490e-01 -2.13744171e-01 4.52619951e-01 -0.49182757 0.92293308 581.00 4.20949743e-01 -1.82497968e-01 4.58807361e-01 -0.40908064 0.94861156 581.25 4.42990226e-01 -1.94079616e-01 4.83639574e-01 -0.41292454 0.95299730 581.50 4.64268951e-01 -2.04658163e-01 5.07376214e-01 -0.41519208 0.95518721 581.75 4.64865756e-01 -2.06328720e-01 5.08597790e-01 -0.41772433 0.96046002 582.00 4.51512458e-01 -1.98353864e-01 4.93160983e-01 -0.41392851 0.96397400 582.25 4.49354512e-01 -1.73378391e-01 4.81642548e-01 -0.36823913 0.94989723 582.50 4.43225931e-01 -1.13740639e-01 4.57587324e-01 -0.25119948 0.96192298 582.75 4.57864918e-01 -7.34724615e-02 4.63722423e-01 -0.15911111 0.96420749 583.00 4.86812355e-01 -4.43193161e-02 4.88825604e-01 -0.09078956 0.96737593 583.25 5.37030437e-01 -3.71926618e-02 5.38316807e-01 -0.06914574 0.97318032 583.50 5.71248549e-01 -2.97398847e-02 5.72022173e-01 -0.05201424 0.98213370 583.75 6.16766955e-01 -3.68103742e-02 6.17864451e-01 -0.05961208 0.97915905 584.00 6.53589916e-01 -5.07464583e-02 6.55557001e-01 -0.07748720 0.98481426 584.25 7.09830532e-01 -6.76306764e-02 7.13045085e-01 -0.09499047 0.97923343 584.50 7.34372717e-01 -1.08155793e-01 7.42294391e-01 -0.14622525 0.98774947 584.75 7.52123008e-01 -1.30460003e-01 7.63353674e-01 -0.17174684 0.98169165 585.00 7.98032636e-01 -1.60187240e-01 8.13950883e-01 -0.19809515 0.98129791 585.25 8.20105532e-01 -2.57916042e-01 8.59705628e-01 -0.30469796 0.96980369 585.50 7.71709753e-01 -3.46603505e-01 8.45972773e-01 -0.42213613 0.96948187 585.75 6.91989108e-01 -3.47699473e-01 7.74431306e-01 -0.46561670 0.94607321 586.00 6.15914052e-01 -3.41008153e-01 7.04014687e-01 -0.50565031 0.90707388 586.25 5.79188887e-01 -2.80561454e-01 6.43563903e-01 -0.45109320 0.89478159 586.50 5.91123968e-01 -2.25378341e-01 6.32631759e-01 -0.36425704 0.89000189 586.75 6.57534741e-01 -1.46978349e-01 6.73761509e-01 -0.21991427 0.82964811 587.00 7.36438967e-01 -1.51541064e-01 7.51869035e-01 -0.20294266 0.85407216 587.25 9.26576857e-01 -2.39817575e-01 9.57108741e-01 -0.25326342 0.87342724 587.50 9.78485277e-01 -3.56536370e-01 1.04141808e+00 -0.34942394 0.87801770 587.75 9.37362883e-01 -5.55582169e-01 1.08964247e+00 -0.53504024 0.89502601 588.00 9.24866964e-01 -5.81287104e-01 1.09237063e+00 -0.56111858 0.87825026 588.25 8.63856832e-01 -7.65860296e-01 1.15446551e+00 -0.72533947 0.85226531 588.50 8.75455347e-01 -9.12935534e-01 1.26486100e+00 -0.80635259 0.85834612 588.75 6.52524183e-01 -1.17612601e+00 1.34501308e+00 -1.06426921 0.81240946 589.00 5.19165678e-01 -1.23718634e+00 1.34170155e+00 -1.17347934 0.82285312 589.25 1.48899417e-01 -1.24363834e+00 1.25252041e+00 -1.45163469 0.83287382 589.50 -5.68789782e-02 -1.21902204e+00 1.22034829e+00 -1.61742203 0.77252387 589.75 -3.28148398e-01 -9.74186303e-01 1.02796903e+00 -1.89570277 0.58600001 590.00 -3.83433083e-01 -8.70246738e-01 9.50973351e-01 -1.98580805 0.59803786 590.25 -4.17746778e-01 -7.87103324e-01 8.91091473e-01 -2.05873201 0.58012342 590.50 -6.12114011e-01 -5.13137197e-01 7.98744856e-01 -2.44392844 0.47406084 590.75 -7.06839493e-01 -1.03654392e-01 7.14399259e-01 -2.99598560 0.47210806 591.00 -5.83960199e-01 1.24118847e-01 5.97005026e-01 2.93216252 0.43496654 591.25 -5.37879075e-01 3.07968203e-01 6.19805061e-01 2.62159381 0.51652780 591.50 -4.19630650e-01 3.65360190e-01 5.56397296e-01 2.42521981 0.46007245 591.75 -3.61282216e-01 5.40185403e-01 6.49865455e-01 2.16028235 0.62741946 592.00 -1.76437500e-01 6.98034664e-01 7.19987905e-01 1.81837399 0.64144913 592.25 3.09255962e-02 8.98412519e-01 8.98944630e-01 1.53638742 0.70201036 592.50 3.25444754e-01 8.17796037e-01 8.80173077e-01 1.19205546 0.65757534 592.75 5.28906173e-01 7.68658908e-01 9.33047832e-01 0.96810875 0.72753725 593.00 7.32442181e-01 6.44778890e-01 9.75813182e-01 0.72183162 0.74917952 593.25 8.48637420e-01 5.36366015e-01 1.00392927e+00 0.56364007 0.87752807 593.50 9.19957964e-01 4.72845486e-01 1.03436237e+00 0.47477368 0.81983588 593.75 1.11926016e+00 3.54034683e-01 1.17391817e+00 0.30635334 0.79733424 594.00 1.17467705e+00 1.95114663e-01 1.19077114e+00 0.16459794 0.70742388 594.25 1.25471469e+00 -1.53300381e-01 1.26404508e+00 -0.12157690 0.77768544 594.50 1.17075808e+00 -4.04483774e-01 1.23866121e+00 -0.33265027 0.80509382 594.75 1.13594876e+00 -5.60071930e-01 1.26651496e+00 -0.45806678 0.85393481 595.00 9.40631297e-01 -5.79522802e-01 1.10482302e+00 -0.55217359 0.80497531 595.25 8.06145247e-01 -5.81694413e-01 9.94101881e-01 -0.62505968 0.77823430 595.50 6.44758157e-01 -4.60933089e-01 7.92573273e-01 -0.62065149 0.73526070 595.75 5.23587615e-01 -4.31865987e-01 6.78713652e-01 -0.68969344 0.73694777 596.00 7.32177465e-01 -2.35773601e-01 7.69202854e-01 -0.31153153 0.75211652 596.25 9.19648045e-01 -1.65841485e-01 9.34481635e-01 -0.17841399 0.85661271 596.50 1.07533695e+00 -3.40248600e-01 1.12788238e+00 -0.30644407 0.83105813 596.75 1.30118903e+00 -5.10775222e-01 1.39784985e+00 -0.37406316 0.88110958 597.00 1.34763116e+00 -8.35142812e-01 1.58542526e+00 -0.55478746 0.86991702 597.25 1.31021861e+00 -1.07454580e+00 1.69449741e+00 -0.68689365 0.84663874 597.50 9.20563402e-01 -1.46574815e+00 1.73085373e+00 -1.01000662 0.78935330 597.75 5.73572938e-01 -1.61873885e+00 1.71735302e+00 -1.23026641 0.84107481 598.00 2.87835136e-01 -1.54309545e+00 1.56971100e+00 -1.38638463 0.84293246 598.25 1.36960022e-01 -1.43552294e+00 1.44204166e+00 -1.47567649 0.82708850 598.50 4.17825643e-03 -1.30489633e+00 1.30490302e+00 -1.56759435 0.83182551 598.75 -4.14433181e-02 -1.21682593e+00 1.21753147e+00 -1.60484171 0.81824710 599.00 -9.53984518e-02 -1.07591009e+00 1.08013119e+00 -1.65923273 0.79905614 599.25 -1.70536476e-01 -1.06910393e+00 1.08261993e+00 -1.72897717 0.82089946 599.50 -2.33480791e-01 -9.59024259e-01 9.87036377e-01 -1.80960708 0.71583651 599.75 -2.94508212e-01 -7.59291706e-01 8.14407135e-01 -1.94080426 0.62654021 600.00 -4.37846767e-01 -5.79132362e-01 7.26019342e-01 -2.21815133 0.63838282 600.25 -3.36396576e-01 -5.02820510e-01 6.04972001e-01 -2.16042584 0.59115415 600.50 -2.22402858e-01 -3.25350108e-01 3.94101159e-01 -2.17041701 0.52973719 600.75 -7.14449944e-02 -2.67325559e-01 2.76708044e-01 -1.83195106 0.34975267 601.00 1.36521835e-01 -2.68860017e-01 3.01535935e-01 -1.10094382 0.43199959 601.25 1.50056867e-01 -3.40845414e-01 3.72414634e-01 -1.15608082 0.37144671 601.50 2.06571541e-01 -6.01182899e-01 6.35682846e-01 -1.23982682 0.43931019 601.75 1.53662250e-01 -7.69722252e-01 7.84910462e-01 -1.37375332 0.53421481 602.00 -6.80390437e-02 -9.00229603e-01 9.02797126e-01 -1.64623256 0.58951198 602.25 -2.25535957e-01 -7.72649626e-01 8.04893728e-01 -1.85480490 0.50809659 602.50 -2.68025493e-01 -5.47795178e-01 6.09850164e-01 -2.02583161 0.49842952 602.75 -2.80836414e-01 -3.89340229e-01 4.80057190e-01 -2.19568398 0.42252980 603.00 -2.09815570e-01 -3.31533132e-01 3.92347794e-01 -2.13503108 0.37871397 603.25 -5.37409564e-02 -3.18237216e-01 3.22742957e-01 -1.73808875 0.31577188 603.50 1.45438504e-01 -3.56539925e-01 3.85062432e-01 -1.18348410 0.49830649 603.75 1.78241189e-01 -4.88965647e-01 5.20439550e-01 -1.22123891 0.69589338 604.00 1.26985760e-01 -6.43952336e-01 6.56353559e-01 -1.37609697 0.76095583 604.25 8.21066569e-03 -9.02521102e-01 9.02558449e-01 -1.56169910 0.85651195 604.50 -1.88035021e-01 -1.01428611e+00 1.03156846e+00 -1.75410184 0.92368390 604.75 -4.73095438e-01 -9.74995595e-01 1.08371385e+00 -2.02255688 0.87343982 605.00 -6.59322730e-01 -9.49081574e-01 1.15562204e+00 -2.17795337 0.90543313 605.25 -8.71140405e-01 -6.61180065e-01 1.09363828e+00 -2.49236767 0.85063824 605.50 -9.59350231e-01 -4.12011096e-01 1.04408142e+00 -2.73594290 0.88981570 605.75 -7.94565080e-01 -7.30654639e-02 7.97917432e-01 -3.04989399 0.78252299 606.00 -6.69698506e-01 1.09760526e-01 6.78633526e-01 2.97914152 0.82634528 606.25 -5.45262935e-01 1.63750894e-01 5.69320668e-01 2.84984646 0.73629775 606.50 -4.57838982e-01 1.79905925e-01 4.91917346e-01 2.76718220 0.63016223 606.75 -3.18550157e-01 1.13691025e-01 3.38230471e-01 2.79878279 0.43838253 607.00 -2.29330701e-01 9.01856556e-02 2.46426506e-01 2.76691362 0.31970376 607.25 -2.25790279e-01 9.46387922e-02 2.44821877e-01 2.74469196 0.30742455 607.50 -2.42243739e-01 4.71654152e-02 2.46792636e-01 2.94929618 0.27612783 607.75 -9.61318064e-02 1.03688421e-01 1.41395237e-01 2.31839543 0.06303018 608.00 -1.64493356e-02 1.76754016e-01 1.77517782e-01 1.66359248 0.09633260 608.25 1.16505332e-01 1.79963927e-01 2.14384018e-01 0.99626403 0.12650378 608.50 1.95218400e-01 1.52335397e-01 2.47621277e-01 0.66263342 0.17376402 608.75 2.77415091e-01 3.11182100e-02 2.79154932e-01 0.11170507 0.27912651 609.00 3.97208617e-01 -7.31200617e-02 4.03882692e-01 -0.18204669 0.53291311 609.25 4.18542907e-01 -3.10389591e-01 5.21075679e-01 -0.63810058 0.55419204 609.50 3.62722447e-01 -4.63766463e-01 5.88767276e-01 -0.90705141 0.57054058 609.75 2.40669337e-01 -6.55538154e-01 6.98320844e-01 -1.21894100 0.74581009 610.00 1.43487407e-01 -7.54111033e-01 7.67640597e-01 -1.38277034 0.79707844 610.25 -1.41345036e-01 -7.77537055e-01 7.90279881e-01 -1.75061828 0.77818050 610.50 -2.91638820e-01 -7.85637833e-01 8.38021483e-01 -1.92624259 0.83415990 610.75 -4.65633621e-01 -7.16208020e-01 8.54264946e-01 -2.14726813 0.89726808 611.00 -5.86969466e-01 -6.20372315e-01 8.54046230e-01 -2.32853511 0.88427337 611.25 -7.54186183e-01 -4.35272744e-01 8.70780776e-01 -2.61814987 0.87124661 611.50 -8.04942428e-01 -3.01826301e-01 8.59669371e-01 -2.78285151 0.82332788 611.75 -8.16724193e-01 -1.49258381e-01 8.30250848e-01 -2.96083489 0.82207713 612.00 -8.00320663e-01 -1.35925167e-02 8.00436081e-01 -3.12461045 0.85086831 612.25 -6.98527683e-01 1.61099865e-01 7.16864067e-01 2.91492814 0.81519423 612.50 -5.99254495e-01 2.68825286e-01 6.56789909e-01 2.71990397 0.76497601 612.75 -5.13904544e-01 3.81226091e-01 6.39868122e-01 2.50334555 0.73624877 613.00 -3.43124616e-01 3.05095419e-01 4.59148905e-01 2.41479443 0.51866327 613.25 -2.03400647e-01 2.75268575e-01 3.42263950e-01 2.20716654 0.46252875 613.50 -2.82354739e-01 1.92806316e-01 3.41904188e-01 2.54246880 0.41784094 613.75 -3.24325751e-01 1.08111038e-01 3.41870135e-01 2.81983529 0.42420205 614.00 -3.21910510e-01 1.38310789e-01 3.50365881e-01 2.73578493 0.45598356 614.25 -3.30168614e-01 2.13919025e-01 3.93411569e-01 2.56668919 0.64879167 614.50 -3.01044279e-01 2.73136933e-01 4.06486706e-01 2.40476000 0.69343477 614.75 -2.33765335e-01 3.23668103e-01 3.99258404e-01 2.19629160 0.71573072 615.00 -2.29115218e-01 3.07731950e-01 3.83657055e-01 2.21078649 0.68259852 615.25 -2.14888826e-01 2.93962374e-01 3.64130588e-01 2.20203130 0.72571962 615.50 -1.55141409e-01 3.39348550e-01 3.73130400e-01 1.99960030 0.73361810 615.75 -9.77161529e-02 4.09328058e-01 4.20830020e-01 1.80513381 0.81942571 616.00 8.79877817e-03 4.33883354e-01 4.33972561e-01 1.55051997 0.87138182 616.25 8.44229489e-02 3.78582433e-01 3.87881288e-01 1.35138868 0.81739737 616.50 1.11666951e-01 3.12664130e-01 3.32006575e-01 1.22776901 0.71602868 616.75 1.51717983e-01 2.43417541e-01 2.86828251e-01 1.01343276 0.67202675 617.00 2.10515596e-01 1.98080364e-01 2.89054747e-01 0.75497350 0.81321860 617.25 2.22270939e-01 1.67972886e-01 2.78602334e-01 0.64714698 0.88247495 617.50 2.14073062e-01 1.09401641e-01 2.40407976e-01 0.47244701 0.81030638 617.75 1.98272389e-01 6.31743115e-02 2.08093570e-01 0.30845412 0.78466657 618.00 1.55479769e-01 -3.62006634e-03 1.55521906e-01 -0.02327899 0.65399311 618.25 1.45901395e-01 -3.08112163e-02 1.49119241e-01 -0.20812051 0.72547015 618.50 1.13600742e-01 -1.63334591e-02 1.14768944e-01 -0.14280086 0.61120592 618.75 8.42574351e-02 -6.28728933e-03 8.44916882e-02 -0.07448196 0.48624049 619.00 8.08377691e-02 -1.78739978e-02 8.27902453e-02 -0.21760833 0.61918277 619.25 7.79316668e-02 -1.51488899e-02 7.93903871e-02 -0.19199250 0.53607549 619.50 6.20536606e-02 -1.89847658e-02 6.48928203e-02 -0.29689840 0.23978244 619.75 6.95101788e-02 -1.29355590e-02 7.07035617e-02 -0.18399119 0.28457702 620.00 6.45468953e-02 -1.96953012e-02 6.74848619e-02 -0.29615806 0.26425134 620.25 6.95651076e-02 -4.16369081e-02 8.10736475e-02 -0.53933902 0.31541249 620.50 6.79801105e-02 -8.98043940e-02 1.12632698e-01 -0.92284310 0.38447245 620.75 4.81150122e-02 -1.30860649e-01 1.39425837e-01 -1.21845745 0.47640849 621.00 7.48597285e-03 -2.25635748e-01 2.25759896e-01 -1.53763125 0.68504488 621.25 -5.07567614e-02 -2.45008171e-01 2.50210417e-01 -1.77507033 0.67509118 621.50 -1.54002330e-01 -2.68655317e-01 3.09664976e-01 -2.09130231 0.69455800 621.75 -2.46944499e-01 -2.57140172e-01 3.56514591e-01 -2.33597113 0.77501999 622.00 -3.27342550e-01 -2.42878370e-01 4.07606486e-01 -2.50325055 0.72095346 622.25 -3.70734630e-01 -1.55097593e-01 4.01869916e-01 -2.74536633 0.58249297 622.50 -4.58402051e-01 3.74321722e-02 4.59927829e-01 3.06011548 0.57856942 622.75 -4.68572007e-01 1.75019746e-01 5.00191601e-01 2.78412253 0.60490308 623.00 -3.07294139e-01 3.19051192e-01 4.42971050e-01 2.33742581 0.62171376 623.25 -1.60380026e-01 2.70258949e-01 3.14263666e-01 2.10637164 0.53957688 623.50 -5.09854208e-02 1.40467525e-01 1.49434396e-01 1.91897818 0.28347170 623.75 -5.67833912e-02 1.07829338e-01 1.21866811e-01 2.05550014 0.14369728 624.00 -1.49428659e-01 7.15054913e-02 1.65656148e-01 2.69527139 0.25994815 624.25 -2.51566865e-01 6.20486217e-02 2.59106000e-01 2.89977070 0.48013514 624.50 -3.31807991e-01 1.25785621e-01 3.54850061e-01 2.77923967 0.66033146 624.75 -3.04340552e-01 1.36558901e-01 3.33573837e-01 2.71981679 0.68339844 625.00 -2.85812424e-01 1.56884605e-01 3.26039140e-01 2.63958854 0.71364474 625.25 -3.56816102e-01 2.42383308e-01 4.31355304e-01 2.54489840 0.78827889 625.50 -3.83685464e-01 3.01396336e-01 4.87908072e-01 2.47573754 0.81416843 625.75 -3.55332067e-01 3.41264356e-01 4.92668487e-01 2.37638667 0.85117781 626.00 -3.28515361e-01 4.01567768e-01 5.18824647e-01 2.25646604 0.88947906 626.25 -3.21903044e-01 4.56081348e-01 5.58239882e-01 2.18540552 0.92872738 626.50 -3.20945056e-01 4.87372586e-01 5.83556139e-01 2.15313836 0.92768740 626.75 -3.30057003e-01 5.11764535e-01 6.08966801e-01 2.14360563 0.90194507 627.00 -3.08343137e-01 5.68666697e-01 6.46882758e-01 2.06764772 0.88451905 627.25 -2.24640637e-01 6.33358838e-01 6.72016989e-01 1.91163561 0.89234252 627.50 -1.87179296e-01 6.75689760e-01 7.01136749e-01 1.84103916 0.90251085 627.75 -1.06006165e-01 7.51578498e-01 7.59017487e-01 1.71091674 0.86736722 628.00 2.73801612e-03 8.19350474e-01 8.19355049e-01 1.56745465 0.85818633 628.25 1.54978078e-01 8.35575437e-01 8.49826168e-01 1.38740564 0.88987438 628.50 2.35897728e-01 8.38381894e-01 8.70937391e-01 1.29651523 0.90216706 628.75 4.36758327e-01 8.30257251e-01 9.38128423e-01 1.08652514 0.87949664 629.00 4.81998061e-01 7.23820679e-01 8.69619748e-01 0.98331906 0.82858560 629.25 5.34849785e-01 4.16900077e-01 6.78137130e-01 0.66209752 0.71305892 629.50 4.85154938e-01 2.91409900e-01 5.65946149e-01 0.54089971 0.59444191 629.75 3.37010628e-01 2.93948730e-01 4.47193492e-01 0.71725554 0.53301615 630.00 3.12177005e-01 3.89498117e-01 4.99162564e-01 0.89515038 0.54818112 630.25 4.35537935e-01 4.78503152e-01 6.47038298e-01 0.83236937 0.61220950 630.50 5.90427707e-01 5.31486829e-01 7.94407406e-01 0.73291044 0.65656784 630.75 6.97421768e-01 3.36220760e-01 7.74236089e-01 0.44921804 0.51490583 631.00 6.79439447e-01 1.08668533e-01 6.88074714e-01 0.15859531 0.46214127 631.25 5.84227183e-01 -6.51516972e-02 5.87848744e-01 -0.11105888 0.50445836 631.50 4.31587266e-01 -9.04035908e-02 4.40953941e-01 -0.20648232 0.37228357 631.75 2.30346122e-01 -4.33520395e-02 2.34390135e-01 -0.18602786 0.18853113 632.00 1.66536669e-01 3.66277282e-02 1.70517016e-01 0.21649109 0.10871537 632.25 1.71408509e-01 2.72085297e-01 3.21576252e-01 1.00862334 0.27997559 632.50 2.76315221e-01 3.44614055e-01 4.41711385e-01 0.89495230 0.47151426 632.75 2.99811433e-01 3.29487974e-01 4.45476398e-01 0.83252131 0.48744768 633.00 3.81440152e-01 2.82439016e-01 4.74624470e-01 0.63736384 0.48479300 633.25 5.95886532e-01 2.66395199e-01 6.52722882e-01 0.42040377 0.69366798 633.50 5.75483352e-01 3.10978723e-01 6.54132139e-01 0.49542612 0.69489049 633.75 5.60862523e-01 1.89518337e-01 5.92016867e-01 0.32585953 0.64225964 634.00 6.68178944e-01 6.46700095e-02 6.71301208e-01 0.09648494 0.70352907 634.25 6.55813628e-01 -3.60869593e-02 6.56805743e-01 -0.05497080 0.65239944 634.50 6.02228906e-01 -1.42663430e-01 6.18896202e-01 -0.23260453 0.62046928 634.75 6.15612088e-01 -1.99470062e-01 6.47121742e-01 -0.31334443 0.70772892 635.00 5.43221710e-01 -1.68780416e-01 5.68837987e-01 -0.30124657 0.62256015 635.25 4.94425991e-01 -2.03968602e-01 5.34846007e-01 -0.39126648 0.56796329 635.50 3.87552254e-01 -2.84950135e-01 4.81033605e-01 -0.63399800 0.51296417 635.75 2.75668183e-01 -3.11838538e-01 4.16216555e-01 -0.84688641 0.49739185 636.00 1.04134965e-01 -2.84434443e-01 3.02897743e-01 -1.21984024 0.29409499 636.25 -1.78429495e-03 -2.49674337e-01 2.49680713e-01 -1.57794269 0.30286688 636.50 -5.49526971e-03 -2.04796666e-01 2.04870379e-01 -1.59762270 0.31892629 636.75 -5.43573281e-02 -7.00710085e-02 8.86829485e-02 -2.23057250 0.06672643 637.00 -1.42929480e-01 3.75733202e-02 1.47785623e-01 2.88452873 0.12169800 637.25 -3.92775297e-02 2.08486889e-01 2.12154441e-01 1.75700708 0.14847288 637.50 2.81558675e-01 4.09077752e-01 4.96608392e-01 0.96798177 0.33021842 637.75 6.06285704e-01 5.01359208e-01 7.86729566e-01 0.69095064 0.47834684 638.00 9.78069414e-01 3.33442597e-01 1.03334590e+00 0.32856219 0.53712633 638.25 9.86759110e-01 -1.53637960e-03 9.86760306e-01 -0.00155699 0.45493354 638.50 9.67958821e-01 -6.03023007e-01 1.14043019e+00 -0.55714840 0.49258000 638.75 8.78227648e-01 -9.29393890e-01 1.27869340e+00 -0.81369644 0.55368996 639.00 3.39327721e-01 -1.13415218e+00 1.18382620e+00 -1.28008223 0.50570694 639.25 7.95320907e-04 -1.11759621e+00 1.11759649e+00 -1.57008469 0.51739967 639.50 -2.94355895e-01 -8.41259975e-01 8.91270855e-01 -1.90738103 0.55704844 639.75 -3.67523593e-01 -6.65665543e-01 7.60384249e-01 -2.07526150 0.52688702 640.00 -4.35726912e-01 -4.41877675e-01 6.20575395e-01 -2.34918602 0.50609780 640.25 -4.62515424e-01 -4.10691945e-01 6.18537300e-01 -2.41547338 0.56250744 640.50 -3.65469690e-01 -3.60196117e-01 5.13136763e-01 -2.36346158 0.60091517 640.75 -3.43835713e-01 -3.09884701e-01 4.62873120e-01 -2.40808294 0.59436702 641.00 -3.56217545e-01 -2.64643726e-01 4.43764848e-01 -2.50263348 0.60963398 641.25 -2.87976777e-01 -2.39519245e-01 3.74566540e-01 -2.44780070 0.47667110 641.50 -2.49381227e-01 -1.78375728e-01 3.06608703e-01 -2.52068955 0.35175025 641.75 -2.85387641e-01 -1.84304199e-01 3.39726572e-01 -2.56817352 0.43386668 642.00 -3.12391132e-01 -1.67096670e-01 3.54273223e-01 -2.65041975 0.58191698 642.25 -3.29350188e-01 -1.51566248e-01 3.62551891e-01 -2.71029063 0.61540563 642.50 -3.20512707e-01 -7.53799433e-02 3.29257545e-01 -2.91060490 0.51591618 642.75 -2.70832910e-01 -1.16046981e-01 2.94647870e-01 -2.73677656 0.49196676 643.00 -2.39410432e-01 -5.37667621e-02 2.45373633e-01 -2.92067814 0.43397125 643.25 -2.54462198e-01 -3.87578150e-02 2.57396928e-01 -2.99044170 0.55040077 643.50 -2.15999253e-01 -9.56593459e-02 2.36233757e-01 -2.72468478 0.59777513 643.75 -2.04917405e-01 -8.79522054e-02 2.22994917e-01 -2.73616313 0.53136646 644.00 -1.83986951e-01 -8.06460155e-02 2.00885485e-01 -2.72849026 0.40415319 644.25 -1.76353545e-01 -1.07788050e-01 2.06685356e-01 -2.59297538 0.45380145 644.50 -1.88998976e-01 -1.18678814e-01 2.23170952e-01 -2.58088654 0.56175006 644.75 -2.13445336e-01 -1.08679856e-01 2.39520819e-01 -2.67063638 0.64469183 645.00 -2.22850985e-01 -1.35418326e-01 2.60769409e-01 -2.59555755 0.72118559 645.25 -2.17917620e-01 -1.61783995e-01 2.71407719e-01 -2.50296753 0.80467741 645.50 -2.28949562e-01 -1.80812205e-01 2.91737819e-01 -2.47313495 0.84295841 645.75 -2.62596642e-01 -1.90192385e-01 3.24237782e-01 -2.51475933 0.84955628 646.00 -3.06473905e-01 -1.90300580e-01 3.60750004e-01 -2.58592134 0.83021873 646.25 -3.06997163e-01 -2.03405164e-01 3.68267455e-01 -2.55643598 0.83369510 646.50 -3.06429198e-01 -2.48699243e-01 3.94651957e-01 -2.45981589 0.82650858 646.75 -3.63193775e-01 -3.39950693e-01 4.97469790e-01 -2.38923837 0.86073947 647.00 -4.21713590e-01 -3.85651391e-01 5.71462464e-01 -2.40083136 0.89335460 647.25 -4.96593634e-01 -4.46586054e-01 6.67865511e-01 -2.40916510 0.86762423 647.50 -6.19851608e-01 -4.32898530e-01 7.56053670e-01 -2.53194765 0.85436577 647.75 -7.75168766e-01 -3.02210340e-01 8.31996217e-01 -2.76985469 0.89048936 648.00 -8.49768866e-01 -2.70754346e-01 8.91860438e-01 -2.83314097 0.91689529 648.25 -8.96963218e-01 -1.60052994e-01 9.11131151e-01 -2.96501238 0.88554147 648.50 -9.15001403e-01 -1.07220591e-01 9.21262081e-01 -3.02494383 0.88083225 648.75 -1.00472069e+00 -6.12430621e-02 1.00658551e+00 -3.08071267 0.90459626 649.00 -1.03490990e+00 -9.77138296e-03 1.03495603e+00 -3.13215116 0.91133080 649.25 -1.03367647e+00 7.29125751e-02 1.03624480e+00 3.07117216 0.90291931 649.50 -1.03224783e+00 1.22688620e-01 1.03951339e+00 3.02329186 0.85515324 649.75 -9.91871880e-01 1.45944337e-01 1.00255153e+00 2.99550063 0.86363505 650.00 -9.77864123e-01 1.53079736e-01 9.89773534e-01 2.98630796 0.91594185 650.25 -9.87840905e-01 2.16745041e-01 1.01133974e+00 2.92560241 0.95158375 650.50 -1.00183314e+00 2.55614608e-01 1.03392866e+00 2.89177576 0.96130805 650.75 -9.79023882e-01 2.85430101e-01 1.01978336e+00 2.85791013 0.95882596 651.00 -9.47737592e-01 2.96119051e-01 9.92921465e-01 2.83875484 0.96019440 651.25 -8.78825796e-01 2.83710328e-01 9.23485967e-01 2.82932573 0.96129585 651.50 -8.83590113e-01 2.73576704e-01 9.24973351e-01 2.84133419 0.95864144 651.75 -8.99631735e-01 2.37560244e-01 9.30468769e-01 2.88342182 0.95972803 652.00 -8.83761665e-01 2.31103609e-01 9.13478822e-01 2.88582016 0.95730325 652.25 -8.68388045e-01 2.49569515e-01 9.03539008e-01 2.86174074 0.93151854 652.50 -8.00416540e-01 2.60173439e-01 8.41639386e-01 2.82731774 0.89601562 652.75 -5.42845679e-01 2.35912378e-01 5.91891951e-01 2.73163184 0.76449625 653.00 -4.01088564e-01 9.84841410e-02 4.13002617e-01 2.90081401 0.67995561 653.25 -2.87107819e-01 -1.31723785e-01 3.15882977e-01 -2.71144848 0.59966629 653.50 -2.48018230e-01 -2.83350865e-01 3.76564410e-01 -2.28979865 0.58500819 653.75 -2.39928755e-01 -5.08151278e-01 5.61946198e-01 -2.01192500 0.66855733 654.00 -3.22700678e-01 -6.56456502e-01 7.31485383e-01 -2.02768502 0.71723919 654.25 -5.18005443e-01 -8.44491128e-01 9.90704246e-01 -2.12100589 0.79442777 654.50 -6.14930973e-01 -9.56371468e-01 1.13700769e+00 -2.14222314 0.77912128 654.75 -7.47273984e-01 -9.95932617e-01 1.24511051e+00 -2.21450595 0.73106870 655.00 -8.10896386e-01 -8.09822857e-01 1.14602182e+00 -2.35685687 0.75590213 655.25 -8.80915307e-01 -7.61555913e-01 1.16446519e+00 -2.42873758 0.66236339 655.50 -7.86344456e-01 -6.59456359e-01 1.02626522e+00 -2.44373339 0.58233369 655.75 -5.64084183e-01 -5.94811366e-01 8.19750893e-01 -2.32968651 0.61273532 656.00 -6.28489061e-01 -4.75578242e-01 7.88145396e-01 -2.49381674 0.59378575 656.25 -6.32394855e-01 -3.41264260e-01 7.18599017e-01 -2.64673975 0.56723024 656.50 -3.82053226e-01 -2.66997673e-01 4.66103449e-01 -2.53163931 0.41342318 656.75 -2.32743859e-01 -2.41585120e-01 3.35459497e-01 -2.33755713 0.35669021 657.00 -1.09273461e-01 -1.40203807e-01 1.77757691e-01 -2.23284332 0.16437358 657.25 -5.57473957e-02 -4.29497829e-02 7.03736881e-02 -2.48514048 0.04761631 657.50 -9.16469903e-02 -3.87065100e-02 9.94855002e-02 -2.74197424 0.08384626 657.75 -1.13397379e-01 -1.99617837e-02 1.15140950e-01 -2.96734398 0.14246444 658.00 -4.39534634e-02 4.96895557e-02 6.63397233e-02 2.29501605 0.02702292 658.25 -3.64920052e-03 1.08197058e-01 1.08258579e-01 1.60451090 0.05231366 658.50 5.80517265e-02 2.01071101e-01 2.09283517e-01 1.28972700 0.17111726 658.75 7.13698559e-02 1.77792915e-01 1.91582821e-01 1.18906533 0.14106423 659.00 6.61803667e-02 1.98273733e-01 2.09027066e-01 1.24864128 0.10261370 659.25 1.48270148e-01 2.21432097e-01 2.66488668e-01 0.98076815 0.12600890 659.50 2.33358184e-01 2.48165984e-01 3.40649964e-01 0.81614041 0.13411666 659.75 3.55733766e-01 1.11889835e-01 3.72915336e-01 0.30473548 0.12312185 660.00 4.49758995e-01 -9.64585792e-02 4.59986316e-01 -0.21126690 0.13775124 660.25 4.88617234e-01 -2.98444449e-02 4.89527826e-01 -0.06100361 0.13797668 660.50 5.97111274e-01 2.78201775e-02 5.97759012e-01 0.04655761 0.28044588 660.75 6.71265979e-01 -9.35195912e-02 6.77749163e-01 -0.13842722 0.37653063 661.00 8.23180360e-01 -2.64082114e-01 8.64502902e-01 -0.31043491 0.57492369 661.25 7.50416083e-01 -8.58479968e-02 7.55310649e-01 -0.11390534 0.50382703 661.50 6.21767077e-01 -9.91212260e-03 6.21846081e-01 -0.01594051 0.45134712 661.75 6.51643573e-01 9.65289236e-04 6.51644288e-01 0.00148131 0.36962706 662.00 8.63815125e-01 2.76443301e-01 9.06971592e-01 0.30972653 0.39232683 662.25 9.31930322e-01 2.57237240e-01 9.66780804e-01 0.26932006 0.38313966 662.50 9.80214191e-01 5.02895957e-01 1.10169152e+00 0.47403065 0.41804619 662.75 1.00008323e+00 3.34721637e-01 1.05461132e+00 0.32297446 0.42976904 663.00 1.25908478e+00 1.34526930e-01 1.26625115e+00 0.10644120 0.57797284 663.25 1.12367678e+00 1.04091466e-01 1.12848772e+00 0.09237109 0.60559661 663.50 9.32044639e-01 6.04340630e-02 9.34001866e-01 0.06474967 0.66971491 663.75 8.05840006e-01 2.04614359e-01 8.31411542e-01 0.24865937 0.63055421 664.00 7.16771115e-01 3.25415955e-01 7.87182555e-01 0.42617751 0.64710899 664.25 5.04324982e-01 3.15016752e-01 5.94625295e-01 0.55833354 0.44796817 664.50 2.06540406e-01 4.48763365e-01 4.94011637e-01 1.13945666 0.43308640 664.75 7.05882313e-02 4.09431135e-01 4.15471483e-01 1.40006905 0.30333106 665.00 -2.81410671e-01 1.85308655e-01 3.36944006e-01 2.55926590 0.20684536 665.25 -4.79492281e-01 9.85803702e-02 4.89521131e-01 2.93882481 0.31523528 665.50 -5.19187123e-01 -1.57744333e-01 5.42621915e-01 -2.84662633 0.30468970 665.75 -5.03802621e-01 -2.06041694e-01 5.44307138e-01 -2.75337490 0.23426815 666.00 -4.69165586e-01 -3.97536068e-02 4.70846787e-01 -3.05706199 0.15370346 666.25 -5.61486390e-01 8.52747706e-02 5.67924953e-01 2.99087117 0.25743839 666.50 -6.03795207e-01 1.36487192e-01 6.19029406e-01 2.91928016 0.27600133 666.75 -6.06565922e-01 1.85230136e-01 6.34217960e-01 2.84521189 0.25303912 667.00 -8.04450848e-01 1.00252635e-02 8.04513314e-01 3.12913105 0.33958719 667.25 -8.25685388e-01 1.08144493e-01 8.32737408e-01 3.01135856 0.46088154 667.50 -8.39058343e-01 2.03090059e-01 8.63287018e-01 2.90411474 0.51818337 667.75 -9.45550756e-01 3.89058978e-02 9.46350834e-01 3.10046957 0.63936142 668.00 -1.02179438e+00 1.65492655e-02 1.02192839e+00 3.12539779 0.72628014 668.25 -9.46862899e-01 1.72818501e-02 9.47020598e-01 3.12334299 0.76049761 668.50 -8.90496257e-01 -1.88635708e-02 8.90696030e-01 -3.12041261 0.82516308 668.75 -8.07341873e-01 -1.24688139e-01 8.16913724e-01 -2.98836053 0.85050915 669.00 -7.54189357e-01 -1.74322440e-01 7.74073575e-01 -2.91444293 0.85053157 669.25 -7.75425247e-01 -2.94081568e-01 8.29317962e-01 -2.77909943 0.83848668 669.50 -8.01122641e-01 -3.74369299e-01 8.84279287e-01 -2.70444074 0.84775707 669.75 -8.87055523e-01 -2.47736948e-01 9.21000053e-01 -2.86925165 0.80022372 670.00 -9.54500973e-01 -1.57488588e-01 9.67406204e-01 -2.97807019 0.81154220 670.25 -1.11774510e+00 -5.39897972e-02 1.11904826e+00 -3.09332774 0.77202656 670.50 -1.18246981e+00 1.06950024e-01 1.18729657e+00 3.05139178 0.76131430 670.75 -1.01015009e+00 2.24099388e-01 1.03470950e+00 2.92328071 0.73576869 671.00 -9.13394737e-01 2.56614553e-01 9.48757595e-01 2.86770699 0.68412275 671.25 -7.18078599e-01 3.22466389e-01 7.87160369e-01 2.71951374 0.64911239 671.50 -6.18809756e-01 2.95450611e-01 6.85723398e-01 2.69614738 0.63850828 671.75 -4.03117526e-01 2.89753669e-01 4.96448314e-01 2.51837215 0.57613910 672.00 -3.57770972e-01 3.03479343e-01 4.69147930e-01 2.43811524 0.65237731 672.25 -2.48174110e-01 2.71959432e-01 3.68174308e-01 2.31049707 0.57522758 672.50 -1.78579183e-01 2.04816536e-01 2.71735787e-01 2.28786689 0.49272945 672.75 -8.12299932e-02 1.10988445e-01 1.37538165e-01 2.20259807 0.33253129 673.00 -3.49691867e-02 8.76384336e-02 9.43575066e-02 1.95045463 0.20468684 673.25 7.40535597e-03 2.49879327e-02 2.60621580e-02 1.28268481 0.02216367 673.50 1.67486046e-03 4.18182179e-03 4.50475205e-03 1.18985058 0.00069169 673.75 8.72357492e-03 -2.09930799e-02 2.27334591e-02 -1.17696110 0.01503075 674.00 -4.22545467e-03 3.82346361e-03 5.69853851e-03 2.40609652 0.00080890 674.25 -1.14211556e-02 7.60219798e-02 7.68751209e-02 1.71991601 0.18982723 674.50 3.91291285e-03 1.40431982e-01 1.40486485e-01 1.54294013 0.36825798 674.75 4.67916257e-03 2.51142376e-01 2.51185962e-01 1.55216697 0.64771131 675.00 -2.82690095e-03 3.17395883e-01 3.17408472e-01 1.57970264 0.65587281 675.25 -1.19919680e-03 4.78789059e-01 4.78790561e-01 1.57330097 0.77753407 675.50 -5.13938905e-03 5.28919533e-01 5.28944501e-01 1.58051279 0.75410404 675.75 -8.86921447e-02 6.16971338e-01 6.23313668e-01 1.71357227 0.75222187 676.00 -2.24126592e-01 6.61086341e-01 6.98045758e-01 1.89766304 0.75712821 676.25 -3.80020939e-01 7.83516413e-01 8.70812198e-01 2.02238808 0.79488009 676.50 -4.76164443e-01 8.22986144e-01 9.50809534e-01 2.09531793 0.83308295 676.75 -6.02603601e-01 8.18211818e-01 1.01617010e+00 2.20559385 0.86368378 677.00 -6.31639839e-01 8.48791534e-01 1.05802455e+00 2.21055172 0.84455720 677.25 -6.74090853e-01 7.65256390e-01 1.01981166e+00 2.29294087 0.82968492 677.50 -6.09496407e-01 7.88744132e-01 9.96796457e-01 2.22869470 0.87006985 677.75 -5.66549366e-01 7.88537573e-01 9.70963279e-01 2.19381835 0.91269018 678.00 -5.51393354e-01 6.88989779e-01 8.82463340e-01 2.24571560 0.92078415 678.25 -5.00872296e-01 6.10470975e-01 7.89650472e-01 2.25789414 0.91682179 678.50 -4.84226248e-01 5.07050698e-01 7.01124432e-01 2.33317326 0.94361437 678.75 -4.75964514e-01 4.63290275e-01 6.64213894e-01 2.36968760 0.95400632 679.00 -5.24258582e-01 3.70322313e-01 6.41861104e-01 2.52660204 0.92428096 679.25 -5.69385843e-01 3.00428626e-01 6.43783813e-01 2.65608124 0.93063847 679.50 -6.50045203e-01 2.92204143e-01 7.12700517e-01 2.71914331 0.92429325 679.75 -6.77440240e-01 3.04286893e-01 7.42641092e-01 2.71942787 0.93379273 680.00 -6.60908022e-01 3.94893212e-01 7.69896137e-01 2.60301267 0.91459828 680.25 -6.65224709e-01 4.36655394e-01 7.95733527e-01 2.56072947 0.91770104 680.50 -6.68217198e-01 4.73075030e-01 8.18727187e-01 2.52554039 0.85691390 680.75 -5.92300191e-01 5.85603529e-01 8.32917168e-01 2.36187967 0.82703856 681.00 -4.88861555e-01 6.19189368e-01 7.88911334e-01 2.23911345 0.84042541 681.25 -4.56244264e-01 6.08800352e-01 7.60786893e-01 2.21392309 0.82044810 681.50 -4.08691299e-01 5.24595660e-01 6.65003146e-01 2.23263769 0.77193969 681.75 -4.02430310e-01 5.56198077e-01 6.86517629e-01 2.19714540 0.79662330 682.00 -3.23319181e-01 6.43391302e-01 7.20060872e-01 2.03646061 0.84212700 682.25 -2.31368138e-01 6.56696297e-01 6.96262337e-01 1.90953768 0.82928158 682.50 -1.27652451e-01 6.51687836e-01 6.64072424e-01 1.76422699 0.79986915 682.75 -5.72994060e-02 6.46056485e-01 6.48592478e-01 1.65925588 0.77685901 683.00 6.33342251e-02 6.45058272e-01 6.48160009e-01 1.47292629 0.85690538 683.25 7.97483382e-02 6.28300534e-01 6.33341423e-01 1.44454437 0.89342638 683.50 1.00637879e-01 6.04190225e-01 6.12514335e-01 1.40574507 0.91857243 683.75 1.00151237e-01 5.77835145e-01 5.86450105e-01 1.39917978 0.91021348 684.00 1.12844166e-01 5.39662204e-01 5.51333928e-01 1.36466486 0.88000868 684.25 1.33496848e-01 5.34790739e-01 5.51201000e-01 1.32617115 0.88592610 684.50 1.63139858e-01 5.53626828e-01 5.77163130e-01 1.28423220 0.89437329 684.75 1.66958596e-01 5.51077007e-01 5.75813373e-01 1.27661900 0.89360745 685.00 1.82453181e-01 5.52011040e-01 5.81382277e-01 1.25157584 0.87992003 685.25 1.94975226e-01 5.42333469e-01 5.76316693e-01 1.22567309 0.82815914 685.50 2.36043779e-01 4.80069815e-01 5.34961394e-01 1.11382172 0.74648442 685.75 2.55084055e-01 5.06450337e-01 5.67062447e-01 1.10421669 0.67633142 686.00 2.32947017e-01 5.37687422e-01 5.85979587e-01 1.16196815 0.60084425 686.25 2.48435887e-01 4.73875897e-01 5.35050236e-01 1.08792678 0.50056578 686.50 4.07442047e-01 3.24109591e-01 5.20630433e-01 0.67197514 0.45632092 686.75 5.09365714e-01 1.88072068e-01 5.42977470e-01 0.35370068 0.50404189 687.00 5.61608619e-01 7.08876342e-02 5.66064747e-01 0.12555849 0.56186935 687.25 5.65717050e-01 1.14409968e-02 5.65832729e-01 0.02022113 0.54994837 687.50 5.10519366e-01 6.99033786e-02 5.15282938e-01 0.13607978 0.51206283 687.75 4.62726361e-01 1.24712105e-01 4.79237722e-01 0.26326056 0.44437139 688.00 4.93486372e-01 2.47786930e-01 5.52202102e-01 0.46533821 0.52444619 688.25 5.20696414e-01 4.61792322e-02 5.22740162e-01 0.08845601 0.29771721 688.50 5.92849421e-01 -1.80640209e-01 6.19759083e-01 -0.29576157 0.34290666 688.75 3.89762663e-01 -5.25024744e-01 6.53885246e-01 -0.93219627 0.43412305 689.00 1.79554794e-01 -5.93817523e-01 6.20370191e-01 -1.27716326 0.58069682 689.25 1.54086738e-01 -4.95164068e-01 5.18584783e-01 -1.26911156 0.66168770 689.50 1.24423793e-01 -4.70382314e-01 4.86560172e-01 -1.31220260 0.75783047 689.75 6.53568578e-02 -4.17630415e-01 4.22713475e-01 -1.41556093 0.82545129 690.00 5.92849637e-02 -3.79365777e-01 3.83970180e-01 -1.41577627 0.84044718 690.25 7.48609420e-02 -3.33689538e-01 3.41983725e-01 -1.35010723 0.63285178 690.50 4.45048224e-02 -2.69083024e-01 2.72738616e-01 -1.40688580 0.42138608 690.75 -1.01910169e-01 -2.27953688e-01 2.49696950e-01 -1.99120702 0.38768349 691.00 -9.74734425e-02 -1.57836847e-01 1.85508873e-01 -2.12402635 0.33318239 691.25 1.31765171e-02 -1.09619246e-01 1.10408332e-01 -1.45116769 0.23521720 691.50 3.41890299e-02 -9.37328920e-02 9.97734675e-02 -1.22104250 0.20017494 691.75 1.15004952e-01 -9.15345010e-02 1.46985386e-01 -0.67224690 0.27943529 692.00 1.39559040e-01 -1.02958548e-01 1.73427761e-01 -0.63560964 0.34031889 692.25 1.45723212e-01 -9.89740836e-02 1.76156532e-01 -0.59662414 0.31288348 692.50 1.76642700e-01 -8.19631620e-02 1.94732133e-01 -0.43443956 0.32363561 692.75 2.02734211e-01 -4.69977485e-02 2.08110424e-01 -0.22779581 0.38712800 693.00 2.41628025e-01 -6.80372507e-02 2.51024241e-01 -0.27447182 0.44003827 693.25 2.72896750e-01 -1.40863449e-01 3.07107713e-01 -0.47650652 0.58875246 693.50 2.69334533e-01 -1.73493655e-01 3.20376558e-01 -0.57225651 0.59377472 693.75 2.17794546e-01 -2.30117034e-01 3.16841149e-01 -0.81290221 0.51124724 694.00 2.69409044e-01 -2.22956442e-01 3.49701026e-01 -0.69133083 0.55449116 694.25 4.09537647e-01 -2.04677146e-01 4.57836017e-01 -0.46346851 0.66037557 694.50 3.76365023e-01 -2.91189618e-01 4.75859248e-01 -0.65849072 0.60995290 694.75 2.73338742e-01 -5.15889758e-01 5.83829008e-01 -1.08356310 0.71478423 695.00 2.01199555e-01 -5.51089137e-01 5.86668985e-01 -1.22073818 0.73271192 695.25 5.18731913e-02 -4.93493442e-01 4.96212258e-01 -1.46606667 0.72549182 695.50 9.33731049e-03 -4.51210404e-01 4.51307007e-01 -1.55010536 0.77459489 695.75 -2.52610026e-02 -3.98737820e-01 3.99537191e-01 -1.63406419 0.82758155 696.00 -6.58166097e-02 -3.59636177e-01 3.65609089e-01 -1.75180217 0.80591669 696.25 -7.96439243e-02 -2.71370331e-01 2.82816214e-01 -1.85626812 0.71506369 696.50 -4.86476862e-02 -2.47878309e-01 2.52606914e-01 -1.76458962 0.66837837 696.75 -3.22154465e-02 -2.36243172e-01 2.38429594e-01 -1.70632599 0.57121261 697.00 3.38761510e-02 -2.35180504e-01 2.37607793e-01 -1.42773714 0.52369121 697.25 5.44820866e-02 -2.52105441e-01 2.57925282e-01 -1.35796104 0.67469350 697.50 6.34844262e-02 -2.79178336e-01 2.86305459e-01 -1.34720119 0.78972235 697.75 7.07375683e-02 -3.12873437e-01 3.20770309e-01 -1.34844461 0.86170587 698.00 3.85019091e-02 -3.56590939e-01 3.58663484e-01 -1.46324079 0.80033898 698.25 -3.55735136e-03 -3.87016271e-01 3.87032619e-01 -1.57998780 0.75982311 698.50 -6.30230420e-02 -3.68025670e-01 3.73382910e-01 -1.74039755 0.57087423 698.75 -1.04579491e-01 -3.43526334e-01 3.59092205e-01 -1.86631176 0.45115993 699.00 -1.19604290e-01 -3.09119430e-01 3.31451366e-01 -1.93997567 0.36264075 699.25 -1.26332103e-01 -3.35494282e-01 3.58491580e-01 -1.93092973 0.41695954 699.50 -1.56940687e-01 -3.32161892e-01 3.67371612e-01 -2.01218862 0.37642573 699.75 -1.74551101e-01 -2.59633809e-01 3.12854282e-01 -2.16268692 0.43641686 700.00 -1.63622896e-01 -2.12149915e-01 2.67917969e-01 -2.22776602 0.42009101 700.25 -1.48202571e-01 -1.82014386e-01 2.34719490e-01 -2.25415737 0.46748164 700.50 -1.70878663e-01 -1.78602809e-01 2.47181069e-01 -2.33409635 0.51379507 700.75 -1.81433629e-01 -1.84693074e-01 2.58900934e-01 -2.34729222 0.63838750 701.00 -1.90571215e-01 -1.83261603e-01 2.64390248e-01 -2.37574516 0.63013801 701.25 -2.14354453e-01 -1.71022799e-01 2.74220038e-01 -2.46816378 0.68325339 701.50 -2.64230707e-01 -1.11748926e-01 2.86889681e-01 -2.74148358 0.71486434 701.75 -2.78104302e-01 -7.10872048e-02 2.87045978e-01 -2.89133775 0.75755116 702.00 -2.51937151e-01 2.71100854e-02 2.53391565e-01 3.03439858 0.76926540 702.25 -2.45002015e-01 6.85485159e-02 2.54410861e-01 2.86878096 0.81830942 702.50 -1.75427640e-01 1.39458386e-01 2.24105998e-01 2.46993095 0.73905134 702.75 -1.41085345e-01 1.83824757e-01 2.31725303e-01 2.22540315 0.72252070 703.00 1.17176681e-02 2.48703135e-01 2.48979021e-01 1.52371606 0.66423296 703.25 6.29895707e-02 2.36530226e-01 2.44773842e-01 1.31053009 0.62727985 703.50 1.50303805e-01 1.49495699e-01 2.11991032e-01 0.78270268 0.50211019 703.75 1.95219663e-01 1.18338895e-01 2.28286686e-01 0.54495363 0.45975178 704.00 3.14352031e-01 5.50262749e-02 3.19131775e-01 0.17329095 0.68192812 704.25 3.24623483e-01 1.02694938e-02 3.24785881e-01 0.03162455 0.69232804 704.50 2.69553912e-01 1.10407517e-02 2.69779928e-01 0.04093646 0.67198639 704.75 2.76625295e-01 5.02758245e-03 2.76670979e-01 0.01817270 0.62942095 705.00 3.19898312e-01 -1.30793104e-02 3.20165580e-01 -0.04086308 0.62203759 705.25 3.27838854e-01 -3.44265590e-02 3.29641475e-01 -0.10462715 0.62448603 705.50 3.26266856e-01 -6.66835983e-02 3.33011656e-01 -0.20160700 0.77228379 705.75 3.21230073e-01 -8.39610865e-02 3.32021420e-01 -0.25565433 0.81392991 706.00 3.17921047e-01 -1.06077645e-01 3.35151098e-01 -0.32204483 0.87542771 706.25 3.30942797e-01 -1.02091656e-01 3.46331982e-01 -0.29922502 0.89352503 706.50 3.75199839e-01 -9.29355304e-02 3.86538397e-01 -0.24280910 0.93140081 706.75 3.94730538e-01 -1.08730097e-01 4.09431840e-01 -0.26878822 0.93217517 707.00 4.31208321e-01 -1.20877119e-01 4.47830206e-01 -0.27330714 0.94158579 707.25 4.52210441e-01 -1.57849951e-01 4.78968568e-01 -0.33583987 0.92352124 707.50 4.86656269e-01 -1.88175976e-01 5.21770565e-01 -0.36896351 0.94132295 707.75 5.12955560e-01 -2.30619970e-01 5.62413528e-01 -0.42251337 0.92915105 708.00 5.42774251e-01 -2.52546746e-01 5.98651607e-01 -0.43549505 0.94607768 708.25 5.72390322e-01 -2.96792886e-01 6.44760962e-01 -0.47834955 0.93138813 708.50 5.75587027e-01 -3.37268818e-01 6.67121189e-01 -0.53002921 0.94761238 708.75 5.79399861e-01 -3.73059582e-01 6.89113671e-01 -0.57205553 0.92646947 709.00 5.99412395e-01 -4.32975129e-01 7.39434028e-01 -0.62555759 0.94654888 709.25 6.32622073e-01 -5.03575728e-01 8.08578506e-01 -0.67230543 0.94628267 709.50 6.32201740e-01 -5.50018628e-01 8.37973467e-01 -0.71599392 0.96057873 709.75 6.02356806e-01 -6.48464026e-01 8.85064582e-01 -0.82224305 0.96513271 710.00 5.82090284e-01 -7.09047237e-01 9.17375105e-01 -0.88341262 0.97346996 710.25 5.50871082e-01 -7.62417850e-01 9.40606149e-01 -0.94510791 0.97599192 710.50 5.39037558e-01 -8.00601736e-01 9.65155235e-01 -0.97822199 0.97986785 710.75 4.94301390e-01 -8.63433625e-01 9.94912805e-01 -1.05085542 0.97411179 711.00 4.57166608e-01 -9.02080442e-01 1.01131124e+00 -1.10173037 0.98396487 711.25 3.83006439e-01 -9.82978447e-01 1.05495998e+00 -1.19925390 0.97048794 711.50 3.00298784e-01 -1.02762227e+00 1.07060118e+00 -1.28648606 0.97401562 711.75 1.95443505e-01 -1.02357026e+00 1.04206250e+00 -1.38212446 0.96752562 712.00 1.18987978e-01 -1.02323304e+00 1.03012815e+00 -1.45502998 0.97467422 712.25 3.53217009e-02 -9.82611050e-01 9.83245696e-01 -1.53486502 0.98285062 712.50 -9.88875852e-03 -9.36108175e-01 9.36160405e-01 -1.58135963 0.97690501 712.75 -6.23027607e-02 -8.35174175e-01 8.37494798e-01 -1.64525693 0.97366962 713.00 -8.04011012e-02 -7.95504562e-01 7.99557281e-01 -1.67152359 0.97851848 713.25 -7.85172587e-02 -7.43797128e-01 7.47929895e-01 -1.67596955 0.97992562 713.50 -7.49899548e-02 -7.12738355e-01 7.16672489e-01 -1.67562451 0.97752089 713.75 -5.78418671e-02 -6.54717513e-01 6.57267605e-01 -1.65891384 0.97215537 714.00 -4.80423368e-02 -6.33599241e-01 6.35418024e-01 -1.64647600 0.97081383 714.25 -3.68033045e-03 -6.00026187e-01 6.00037473e-01 -1.57692987 0.97142353 714.50 3.22022343e-02 -5.83514648e-01 5.84402540e-01 -1.51566557 0.96873535 714.75 1.03675416e-01 -5.29805245e-01 5.39853860e-01 -1.37755236 0.95916523 715.00 1.47827745e-01 -5.17796643e-01 5.38485288e-01 -1.29270050 0.94616102 715.25 2.04806152e-01 -5.08683566e-01 5.48365325e-01 -1.18803341 0.95291844 715.50 2.37860065e-01 -4.99195106e-01 5.52967598e-01 -1.12613529 0.95292413 715.75 3.08351227e-01 -4.80236153e-01 5.70707668e-01 -1.00000717 0.92361876 716.00 3.42784655e-01 -4.68101578e-01 5.80189975e-01 -0.93872831 0.89706689 716.25 4.16384662e-01 -4.60656066e-01 6.20951043e-01 -0.83583352 0.88389107 716.50 4.43521072e-01 -4.41183126e-01 6.25582522e-01 -0.78275554 0.84032351 716.75 5.59961894e-01 -4.18538578e-01 6.99093602e-01 -0.64186145 0.84258456 717.00 5.40609071e-01 -3.86646184e-01 6.64645348e-01 -0.62085778 0.79257757 717.25 6.05769604e-01 -2.42559899e-01 6.52527485e-01 -0.38086503 0.67916015 717.50 6.26034777e-01 -8.80032249e-02 6.32189931e-01 -0.13965732 0.52520939 717.75 6.92831793e-01 1.88345542e-01 7.17976278e-01 0.26543428 0.47108398 718.00 7.16516604e-01 2.94253327e-01 7.74584446e-01 0.38967241 0.33824083 718.25 8.36587284e-01 3.80069263e-01 9.18874817e-01 0.42643164 0.30282959 718.50 3.03097727e-02 1.00338317e-01 1.04816316e-01 1.27743626 0.00542603 718.75 -3.34984838e-01 -2.21299033e-02 3.35715019e-01 -3.07562610 0.09058472 719.00 -4.34624564e-01 -1.78034834e-02 4.34989052e-01 -3.10065264 0.16526208 719.25 -4.44908858e-01 -8.14414504e-02 4.52301450e-01 -2.96054509 0.14800621 719.50 -4.50372952e-01 -2.96679083e-01 5.39309071e-01 -2.55909721 0.25905808 719.75 -3.76188474e-01 -4.12882965e-01 5.58560749e-01 -2.30972459 0.33970033 720.00 -2.27919459e-01 -6.73835624e-01 7.11337984e-01 -1.89695809 0.53416274 720.25 -1.42057572e-01 -7.10165025e-01 7.24233883e-01 -1.76822515 0.57590140 720.50 -7.45029986e-02 -4.84849709e-01 4.90540454e-01 -1.72326580 0.40601099 720.75 1.60959392e-02 -3.85871660e-01 3.86207221e-01 -1.52910730 0.31675725 721.00 1.35730809e-01 -3.06936672e-01 3.35608362e-01 -1.15443848 0.34615730 721.25 1.39736916e-01 -2.56182667e-01 2.91814949e-01 -1.07144685 0.35639099 721.50 1.19053783e-01 -1.39557908e-02 1.19868959e-01 -0.11669003 0.08307212 721.75 1.46403886e-01 6.36164561e-02 1.59628166e-01 0.40991243 0.17542122 722.00 1.14850868e-02 1.20724352e-01 1.21269437e-01 1.47594699 0.10017327 722.25 -3.60389916e-02 1.20432820e-01 1.25709479e-01 1.86156087 0.08065757 722.50 -5.90391394e-02 7.80781309e-02 9.78867433e-02 2.21822477 0.06419817 722.75 -1.26985706e-01 1.24526948e-02 1.27594824e-01 3.04384144 0.08931540 723.00 -2.07841475e-01 -1.05317885e-01 2.33002008e-01 -2.67258177 0.13848271 723.25 -2.73521827e-01 -1.71237329e-01 3.22701739e-01 -2.58224129 0.23134696 723.50 -1.75355883e-01 -3.17694501e-01 3.62876676e-01 -2.07514605 0.18939910 723.75 -1.48286183e-02 -4.45906412e-01 4.46152907e-01 -1.60403908 0.25658320 724.00 7.61382688e-02 -4.04089921e-01 4.11200317e-01 -1.38456062 0.30027128 724.25 1.43222923e-01 -3.65096471e-01 3.92183935e-01 -1.19695595 0.26821469 724.50 2.46994827e-01 -3.99120040e-01 4.69364732e-01 -1.01663282 0.33953573 724.75 2.17336353e-01 -4.43067431e-01 4.93501610e-01 -1.11475613 0.37976199 725.00 3.60182955e-01 -4.72653336e-01 5.94249895e-01 -0.91963109 0.50544167 725.25 4.33930443e-01 -4.39656349e-01 6.17732413e-01 -0.79195255 0.56826650 725.50 3.87243629e-01 -3.98149015e-01 5.55409998e-01 -0.79928254 0.42165100 725.75 4.16107140e-01 -4.09735381e-01 5.83976227e-01 -0.77768285 0.37283537 726.00 4.41366167e-01 -4.14589590e-01 6.05548199e-01 -0.75412570 0.38217722 726.25 4.40797047e-01 -4.89206990e-01 6.58502480e-01 -0.83740470 0.57065803 726.50 5.11097032e-01 -4.82787424e-01 7.03067474e-01 -0.75692206 0.62201294 726.75 5.61307517e-01 -3.81238824e-01 6.78534575e-01 -0.59662790 0.55613787 727.00 5.36261902e-01 -3.60327577e-01 6.46074911e-01 -0.59163390 0.50467137 727.25 4.78214592e-01 -4.78094553e-01 6.76212687e-01 -0.78527264 0.51833562 727.50 4.88274873e-01 -4.70983882e-01 6.78408556e-01 -0.76737475 0.52728187 727.75 4.91996124e-01 -5.26728707e-01 7.20765785e-01 -0.81947914 0.60742230 728.00 4.38856095e-01 -5.94332718e-01 7.38800414e-01 -0.93475976 0.62783090 728.25 4.45916622e-01 -5.93407241e-01 7.42276086e-01 -0.92636706 0.56440589 728.50 5.71443379e-01 -5.52700736e-01 7.95000401e-01 -0.76872690 0.66039402 728.75 6.27569597e-01 -6.60873451e-01 9.11371119e-01 -0.81124055 0.74311199 729.00 7.44260968e-01 -7.03511895e-01 1.02413543e+00 -0.75725955 0.76964604 729.25 7.72749935e-01 -6.02399132e-01 9.79809765e-01 -0.66214800 0.69058612 729.50 8.24839597e-01 -5.96575690e-01 1.01797000e+00 -0.62616849 0.66588685 729.75 7.19406466e-01 -7.08299092e-01 1.00957083e+00 -0.77761844 0.69636930 730.00 7.00839104e-01 -6.95565912e-01 9.87414496e-01 -0.78162192 0.62022060 730.25 5.03754156e-01 -5.90326691e-01 7.76050161e-01 -0.86436173 0.53001002 730.50 5.37578481e-01 -6.57370221e-01 8.49191516e-01 -0.88531279 0.68204886 730.75 5.65909610e-01 -6.85395348e-01 8.88830957e-01 -0.88059842 0.70780221 731.00 6.39948807e-01 -6.42742297e-01 9.07001728e-01 -0.78757600 0.69898744 731.25 5.69659737e-01 -6.70178096e-01 8.79574270e-01 -0.86629502 0.69478464 731.50 4.70331076e-01 -6.48688540e-01 8.01254106e-01 -0.94345592 0.56393518 731.75 4.24720252e-01 -4.67444510e-01 6.31578706e-01 -0.83324991 0.40131436 732.00 4.82628221e-01 -3.77816051e-01 6.12923297e-01 -0.66418365 0.41726103 732.25 3.93148359e-01 -3.80698945e-01 5.47263482e-01 -0.76931186 0.34017952 732.50 3.85034557e-01 -3.94538955e-01 5.51282684e-01 -0.79758935 0.36758932 732.75 3.38072685e-01 -3.01124795e-01 4.52735334e-01 -0.72765885 0.31946059 733.00 3.25071342e-01 -2.68894706e-01 4.21871711e-01 -0.69109980 0.30796286 733.25 2.11453711e-01 -2.37070161e-01 3.17671108e-01 -0.84244898 0.21068825 733.50 2.78503098e-01 -2.33905983e-01 3.63697655e-01 -0.69858273 0.23920311 733.75 3.57144644e-01 -3.39562163e-01 4.92802963e-01 -0.76016696 0.41154650 734.00 4.38220634e-01 -3.41010031e-01 5.55270354e-01 -0.66128734 0.42889894 734.25 5.59064721e-01 -1.86087047e-01 5.89221310e-01 -0.32131928 0.40381770 734.50 4.87114695e-01 -1.78397078e-01 5.18754512e-01 -0.35106175 0.33763122 734.75 3.58596709e-01 -2.44019233e-01 4.33747606e-01 -0.59750737 0.15379896 735.00 2.64342068e-01 -3.08086031e-01 4.05947942e-01 -0.86166819 0.13308319 735.25 1.56722098e-01 -3.75065927e-01 4.06492639e-01 -1.17499553 0.18153458 735.50 4.63203448e-02 -2.03866112e-01 2.09062111e-01 -1.34737972 0.07198336 735.75 -1.38493736e-01 2.36406613e-01 2.73986499e-01 2.10073045 0.10106990 736.00 -2.33423709e-01 2.92213142e-01 3.73998861e-01 2.24481318 0.18934649 736.25 -2.27627932e-01 4.01642942e-01 4.61661703e-01 2.08640237 0.46122142 736.50 -1.90890631e-01 5.09340325e-01 5.43936393e-01 1.92937422 0.60351104 736.75 -7.97958597e-02 6.53914809e-01 6.58765479e-01 1.69222390 0.51978717 737.00 1.75609103e-03 7.05226089e-01 7.05228275e-01 1.56830622 0.51550288 737.25 -7.90921257e-02 7.86806648e-01 7.90771943e-01 1.67098273 0.59867915 737.50 -1.54796960e-01 7.20455571e-01 7.36897774e-01 1.78243850 0.65635805 737.75 -2.84132939e-01 7.39493498e-01 7.92200834e-01 1.93763128 0.63492292 738.00 -3.36084231e-01 7.34852066e-01 8.08059509e-01 1.99974527 0.61879394 738.25 -4.18419800e-01 7.17772241e-01 8.30826166e-01 2.09857897 0.67638461 738.50 -3.47312711e-01 5.95004960e-01 6.88953570e-01 2.09915473 0.65322086 738.75 -2.17821577e-01 5.00609751e-01 5.45945384e-01 1.98120111 0.56459976 739.00 -1.96822005e-01 4.27806860e-01 4.70911468e-01 2.00199458 0.44440440 739.25 -2.56372685e-01 3.12605807e-01 4.04288690e-01 2.25768269 0.37884905 739.50 -2.93601809e-01 2.46341079e-01 3.83257028e-01 2.44350111 0.36861677 739.75 -2.80693685e-01 1.35639369e-01 3.11748269e-01 2.69145152 0.34916568 740.00 -2.85504453e-01 1.49144934e-01 3.22113340e-01 2.66019318 0.38052626 740.25 -3.04709004e-01 1.29072021e-01 3.30918666e-01 2.74091597 0.40477642 740.50 -3.64033097e-01 -9.84710636e-03 3.64166255e-01 -3.11454922 0.45305585 740.75 -3.31276750e-01 -3.40732919e-03 3.31294272e-01 -3.13130757 0.45870729 741.00 -3.27006715e-01 -5.01006881e-02 3.30822416e-01 -2.98956486 0.41505429 741.25 -3.35227963e-01 -1.36938574e-01 3.62118710e-01 -2.75378547 0.46061430 741.50 -2.98939635e-01 -1.76737925e-01 3.47276834e-01 -2.60765694 0.47119932 741.75 -2.77548980e-01 -2.43158775e-01 3.68998138e-01 -2.42214383 0.57241611 742.00 -3.53652292e-01 -3.12870596e-01 4.72184237e-01 -2.41730405 0.53710041 742.25 -3.62402118e-01 -3.28457759e-01 4.89101007e-01 -2.40528850 0.37960539 742.50 -3.86776406e-01 -4.72822675e-01 6.10866001e-01 -2.25642637 0.30805485 742.75 -4.54788793e-01 -3.55276210e-01 5.77108336e-01 -2.47842726 0.21866915 743.00 -1.29975728e-01 3.53995971e-02 1.34710138e-01 2.87568672 0.01074334 743.25 -1.99921779e-02 2.50696098e-01 2.51491989e-01 1.65037458 0.03911149 743.50 -6.12345855e-02 3.48552125e-01 3.53890178e-01 1.74470435 0.15424796 743.75 -9.23943415e-02 2.55797574e-01 2.71972634e-01 1.91741471 0.19448496 744.00 -1.00964288e-01 2.45172769e-02 1.03898432e-01 2.90337241 0.06847655 744.25 -1.29486975e-01 -3.23843433e-02 1.33475176e-01 -2.89652241 0.09954734 744.50 -1.95098011e-01 -9.87489729e-02 2.18665483e-01 -2.67303669 0.30995611 744.75 -2.04322256e-01 -1.08060559e-01 2.31137770e-01 -2.65511420 0.45363505 745.00 -2.70653328e-01 -1.32432094e-01 3.01316252e-01 -2.68653739 0.67598207 745.25 -3.24153809e-01 -1.36392337e-01 3.51679629e-01 -2.74331518 0.76758475 745.50 -3.92269934e-01 -1.48687322e-01 4.19504017e-01 -2.77928182 0.86085872 745.75 -4.13308949e-01 -1.33236319e-01 4.34253617e-01 -2.82974591 0.88826676 746.00 -4.45162159e-01 -1.24381786e-01 4.62212263e-01 -2.86913317 0.88905387 746.25 -4.82794283e-01 -1.03989297e-01 4.93866473e-01 -2.92944329 0.88661171 746.50 -5.07573662e-01 -6.44575929e-02 5.11650079e-01 -3.01527718 0.90545272 746.75 -5.03213767e-01 -2.25265751e-02 5.03717721e-01 -3.09685710 0.88643017 747.00 -4.94709253e-01 5.25707122e-02 4.97494648e-01 3.03572409 0.86000841 747.25 -4.81494697e-01 6.32605126e-02 4.85632614e-01 3.01095727 0.82412307 747.50 -4.49073061e-01 9.73504661e-02 4.59503784e-01 2.92811489 0.82488776 747.75 -3.98473352e-01 9.98848969e-02 4.10801661e-01 2.89598449 0.76820564 748.00 -3.36468068e-01 7.30178204e-02 3.44299815e-01 2.92789358 0.78082384 748.25 -3.25167797e-01 5.46342590e-02 3.29725641e-01 2.97512881 0.75379032 748.50 -3.00418889e-01 1.02120245e-03 3.00420624e-01 3.13819340 0.68986476 748.75 -2.96780729e-01 -5.40302824e-02 3.01658868e-01 -2.96151036 0.67018154 749.00 -3.44940677e-01 -1.19959534e-01 3.65204546e-01 -2.80690711 0.75445185 749.25 -3.97432603e-01 -1.44588503e-01 4.22916669e-01 -2.79267153 0.66012144 749.50 -4.85923174e-01 -2.81706534e-01 5.61675976e-01 -2.61620739 0.58438174 749.75 -5.73624004e-01 -2.81945196e-01 6.39169454e-01 -2.68475550 0.59406636 750.00 -7.76872444e-01 -1.49565957e-01 7.91138907e-01 -2.95139657 0.69895437 750.25 -8.33874753e-01 1.00982936e-01 8.39967057e-01 3.02107865 0.72345266 750.50 -9.25761940e-01 1.24789660e-01 9.34134695e-01 3.00760359 0.81600980 750.75 -8.56230291e-01 1.75389933e-01 8.74009119e-01 2.93954792 0.76508484 751.00 -6.23048494e-01 1.87821872e-01 6.50743022e-01 2.84880037 0.61551952 751.25 -6.46045309e-01 2.75881695e-01 7.02485054e-01 2.73800257 0.72709695 751.50 -6.98057427e-01 3.24626700e-01 7.69848469e-01 2.70629965 0.77520412 751.75 -6.69880812e-01 4.30469390e-01 7.96268923e-01 2.57043294 0.77962635 752.00 -6.59172460e-01 5.20654622e-01 8.39993790e-01 2.47306467 0.81250049 752.25 -6.10357831e-01 5.09464738e-01 7.95041509e-01 2.44604927 0.77078985 752.50 -5.98383552e-01 5.10908096e-01 7.86822698e-01 2.43488868 0.71623329 752.75 -6.21594693e-01 4.81827191e-01 7.86471490e-01 2.48219082 0.76840464 753.00 -6.04779921e-01 4.72045225e-01 7.67193227e-01 2.47884067 0.76402659 753.25 -5.46126000e-01 4.07437302e-01 6.81365367e-01 2.50062434 0.60207483 753.50 -4.88194981e-01 3.95815933e-01 6.28493908e-01 2.46031647 0.57701689 753.75 -5.78126303e-01 4.54260517e-01 7.35243252e-01 2.47560371 0.68740620 754.00 -6.17524405e-01 4.99610198e-01 7.94321560e-01 2.46135569 0.75794750 754.25 -5.42345119e-01 5.62862617e-01 7.81634539e-01 2.33763224 0.65557983 754.50 -5.37954550e-01 6.02349798e-01 8.07601621e-01 2.29978242 0.67243428 754.75 -5.61837087e-01 6.96436166e-01 8.94809614e-01 2.24962847 0.78220981 755.00 -5.96003291e-01 7.14305762e-01 9.30297073e-01 2.26615269 0.77878382 755.25 -5.22020871e-01 9.38339004e-01 1.07377180e+00 2.07848214 0.72682666 755.50 -4.63871802e-01 1.00438976e+00 1.10633441e+00 2.00345630 0.65641736 755.75 -3.56404606e-01 1.00193395e+00 1.06343589e+00 1.91255484 0.49904535 756.00 -2.31900401e-01 9.21515344e-01 9.50246455e-01 1.81732841 0.43893555 756.25 -4.02209896e-02 8.93226669e-01 8.94131763e-01 1.61579480 0.41010750 756.50 4.15397956e-02 7.29873436e-01 7.31054572e-01 1.51394396 0.24147869 756.75 2.75294162e-01 -6.55099617e-02 2.82981326e-01 -0.23361850 0.03591212 757.00 4.50494180e-01 -1.94714500e-01 4.90773616e-01 -0.40797369 0.16383105 757.25 3.59670353e-01 -9.79009126e-03 3.59803570e-01 -0.02721290 0.14476609 757.50 4.55520598e-01 -1.62466275e-01 4.83626205e-01 -0.34259622 0.30067601 757.75 6.02976726e-01 -2.36947145e-01 6.47861777e-01 -0.37442475 0.52108924 758.00 6.30821373e-01 -1.60536133e-01 6.50928149e-01 -0.24919768 0.58068468 758.25 6.83225504e-01 -9.23645731e-02 6.89440573e-01 -0.13437434 0.77827952 758.50 6.37215212e-01 -1.00392623e-01 6.45075116e-01 -0.15626454 0.79206043 758.75 6.83733547e-01 -9.45907184e-02 6.90245585e-01 -0.13747182 0.86815093 759.00 6.97843380e-01 -1.22199984e-01 7.08461869e-01 -0.17335327 0.87508856 759.25 7.35318907e-01 -1.79202910e-01 7.56840524e-01 -0.23904783 0.89547163 759.50 6.76129233e-01 -2.08551440e-01 7.07562324e-01 -0.29919011 0.88338263 759.75 6.30046569e-01 -2.58688486e-01 6.81086200e-01 -0.38959905 0.90417013 760.00 5.76840581e-01 -3.07652693e-01 6.53754721e-01 -0.48996324 0.86016083 760.25 4.99777854e-01 -3.71126925e-01 6.22505500e-01 -0.63873780 0.86509162 760.50 4.11381772e-01 -3.68063687e-01 5.52001666e-01 -0.72987976 0.84603194 760.75 3.39348061e-01 -3.96024209e-01 5.21528792e-01 -0.86231747 0.85444043 761.00 2.86436377e-01 -3.53199629e-01 4.54748036e-01 -0.88939852 0.84216728 761.25 2.38647088e-01 -2.85415307e-01 3.72040764e-01 -0.87440408 0.78162497 761.50 2.17251875e-01 -2.74197175e-01 3.49832057e-01 -0.90075595 0.71800293 761.75 2.20248626e-01 -2.81332432e-01 3.57291749e-01 -0.90658393 0.71800312 762.00 1.93972577e-01 -3.02030278e-01 3.58953548e-01 -0.99990350 0.65893722 762.25 1.03064122e-01 -3.30483096e-01 3.46181007e-01 -1.26849555 0.62248899 762.50 4.59019051e-02 -3.16610009e-01 3.19920119e-01 -1.42682016 0.61607616 762.75 -1.68347789e-02 -2.67549507e-01 2.68078623e-01 -1.63363559 0.55941787 763.00 -3.80660555e-02 -1.76438490e-01 1.80498104e-01 -1.78328627 0.47988913 763.25 -2.86266817e-02 -1.16739444e-01 1.20198106e-01 -1.81126980 0.36218573 763.50 3.11532329e-02 -5.44427353e-02 6.27258746e-02 -1.05105365 0.17002584 763.75 4.58616469e-02 -4.58890110e-02 6.48775153e-02 -0.78569641 0.21273519 764.00 1.00593483e-01 -3.31743439e-02 1.05922547e-01 -0.31855476 0.40627531 764.25 1.17280964e-01 -5.73738121e-02 1.30562548e-01 -0.45497010 0.49952672 764.50 1.34786350e-01 -9.86174062e-02 1.67011236e-01 -0.63165801 0.70125072 764.75 1.22356191e-01 -1.04152969e-01 1.60682539e-01 -0.70520633 0.70444009 765.00 8.79053154e-02 -1.13555914e-01 1.43604631e-01 -0.91203952 0.76320754 765.25 7.62830153e-02 -1.08795919e-01 1.32874567e-01 -0.95929430 0.76606848 765.50 6.76243041e-02 -9.35711556e-02 1.15449589e-01 -0.94499434 0.63399632 765.75 6.75023336e-02 -9.53796164e-02 1.16849631e-01 -0.95490603 0.60750144 766.00 9.39064542e-02 -8.37169933e-02 1.25805235e-01 -0.72809545 0.56918806 766.25 1.00952271e-01 -8.35703493e-02 1.31054814e-01 -0.69147591 0.55285846 766.50 1.00365288e-01 -1.20354874e-01 1.56711477e-01 -0.87571706 0.60863436 766.75 9.52046136e-02 -1.34995846e-01 1.65190184e-01 -0.95656153 0.66480497 767.00 8.84082783e-02 -1.38990670e-01 1.64725317e-01 -1.00427366 0.68784835 767.25 7.85050986e-02 -1.46592722e-01 1.66290338e-01 -1.07912877 0.72321404 767.50 3.03045251e-02 -1.72469450e-01 1.75111608e-01 -1.39686230 0.67988671 767.75 2.63059474e-02 -1.91714068e-01 1.93510430e-01 -1.43443339 0.70565475 768.00 4.07205032e-02 -2.19994630e-01 2.23731528e-01 -1.38777008 0.78265473 768.25 2.18018856e-02 -2.46225718e-01 2.47189050e-01 -1.48248234 0.76366901 768.50 -7.00760563e-02 -2.74453404e-01 2.83258406e-01 -1.82078469 0.76092790 768.75 -1.27513427e-01 -2.88186864e-01 3.15137022e-01 -1.98736890 0.75636001 769.00 -1.84733588e-01 -2.70598493e-01 3.27643164e-01 -2.16980686 0.67108721 769.25 -2.11147177e-01 -2.59028153e-01 3.34183654e-01 -2.25470793 0.62057584 769.50 -2.48860966e-01 -2.23309286e-01 3.34363302e-01 -2.41025715 0.57818750 769.75 -2.90998445e-01 -1.61013384e-01 3.32573909e-01 -2.63620901 0.56562254 770.00 -3.81895499e-01 -1.18053707e-01 3.99725969e-01 -2.84178484 0.55195935 770.25 -4.08743037e-01 -1.77872208e-03 4.08746907e-01 -3.13724099 0.36240184 770.50 -4.11580886e-01 2.64267356e-01 4.89117635e-01 2.57080612 0.39443083 770.75 -2.33318853e-01 3.87542292e-01 4.52356845e-01 2.11271995 0.43632225 771.00 -9.61392174e-02 4.19036385e-01 4.29923529e-01 1.79632260 0.57628277 771.25 -8.43106538e-04 3.36907919e-01 3.36908974e-01 1.57329881 0.48125787 771.50 5.32879140e-03 3.16178233e-01 3.16223135e-01 1.55394416 0.50162217 771.75 -4.55761356e-03 2.60693836e-01 2.60733672e-01 1.58827717 0.49593116 772.00 -3.15961922e-02 2.45839597e-01 2.47861709e-01 1.69861920 0.56835070 772.25 1.37123273e-02 2.80008007e-01 2.80343561e-01 1.52186422 0.72361134 772.50 3.11703075e-02 2.84943137e-01 2.86642947e-01 1.46183824 0.76100996 772.75 2.79159044e-02 2.64911166e-01 2.66377971e-01 1.46580545 0.78900809 773.00 2.55958767e-03 2.65158683e-01 2.65171036e-01 1.56114359 0.78154543 773.25 3.86283996e-02 2.74989232e-01 2.77689091e-01 1.43123709 0.81892776 773.50 6.09080857e-02 2.81786378e-01 2.88293874e-01 1.35792137 0.83250776 773.75 7.38957912e-02 2.67125884e-01 2.77158485e-01 1.30091271 0.83049583 774.00 9.20590651e-02 2.69839025e-01 2.85110454e-01 1.24201579 0.83841016 774.25 1.42575855e-01 2.67073774e-01 3.02747875e-01 1.08044115 0.87897759 774.50 1.74759754e-01 2.58164548e-01 3.11752956e-01 0.97572082 0.89897224 774.75 1.94939437e-01 2.41304467e-01 3.10208365e-01 0.89128302 0.92258201 775.00 2.11054671e-01 2.10839096e-01 2.98323982e-01 0.78488719 0.89778103 775.25 2.45987934e-01 1.41343316e-01 2.83704065e-01 0.52152949 0.84730927 775.50 2.44273546e-01 1.07643912e-01 2.66939651e-01 0.41506768 0.83242605 775.75 2.46072896e-01 6.41246902e-02 2.54290869e-01 0.25492273 0.84585070 776.00 2.22077215e-01 3.28095929e-02 2.24487770e-01 0.14667853 0.81839388 776.25 1.42228038e-01 7.83007242e-03 1.42443410e-01 0.05499743 0.65474377 776.50 1.34950617e-01 1.54599050e-02 1.35833272e-01 0.11406247 0.61852148 776.75 1.18165703e-01 1.49687107e-02 1.19110015e-01 0.12600447 0.56777445 777.00 1.02824723e-01 2.04135176e-02 1.04831462e-01 0.19597913 0.59816213 777.25 6.37449735e-02 3.05232586e-02 7.06759575e-02 0.44657186 0.28848598 777.50 5.56804729e-02 4.90712138e-02 7.42179161e-02 0.72238715 0.31057219 777.75 5.93295342e-02 6.02150268e-02 8.45330887e-02 0.79280525 0.41707685 778.00 7.40413712e-02 6.65394412e-02 9.95470837e-02 0.73208491 0.53194127 778.25 9.31840978e-02 4.40577613e-02 1.03074548e-01 0.44165461 0.59879311 778.50 9.37832235e-02 3.26749335e-02 9.93123572e-02 0.33525688 0.62798492 778.75 8.44667940e-02 2.49878991e-02 8.80853812e-02 0.28762768 0.57429448 779.00 6.70699282e-02 2.89199519e-02 7.30392969e-02 0.40710280 0.43398960 779.25 4.36183467e-02 3.37683963e-02 5.51621678e-02 0.65879677 0.24734365 779.50 3.64471238e-02 5.73048790e-02 6.79134890e-02 1.00431081 0.38195838 779.75 2.90434530e-02 8.52470989e-02 9.00588143e-02 1.24243294 0.58053416 780.00 4.48736712e-02 1.02272617e-01 1.11684084e-01 1.15732439 0.65370830 780.25 9.25825198e-02 1.22531278e-01 1.53575509e-01 0.92373182 0.70354573 780.50 1.17306925e-01 1.01511077e-01 1.55130311e-01 0.71333601 0.81241941 780.75 1.24540325e-01 8.24551541e-02 1.49362462e-01 0.58481768 0.84264460 781.00 1.16367081e-01 7.29586808e-02 1.37347249e-01 0.56001476 0.74107565 781.25 9.03491977e-02 6.98354225e-02 1.14192661e-01 0.65802812 0.62577471 781.50 9.19582291e-02 6.43124210e-02 1.12215878e-01 0.61030006 0.68856702 781.75 7.62043391e-02 7.13999533e-02 1.04427270e-01 0.75286056 0.69128317 782.00 7.43785327e-02 8.72861170e-02 1.14677951e-01 0.86507088 0.70437875 782.25 7.82795451e-02 9.71896906e-02 1.24793923e-01 0.89275284 0.73032580 782.50 1.03908786e-01 1.24685744e-01 1.62307026e-01 0.87603912 0.78875584 782.75 1.25037150e-01 1.45129772e-01 1.91564453e-01 0.85963264 0.84103601 783.00 1.60812101e-01 1.36782195e-01 2.11115846e-01 0.70482577 0.81380741 783.25 2.01241998e-01 1.25728963e-01 2.37289094e-01 0.55843033 0.83223142 783.50 2.38507551e-01 8.21285189e-02 2.52251750e-01 0.33162674 0.83609903 783.75 2.64078382e-01 5.32282902e-02 2.69389389e-01 0.19889748 0.89977846 784.00 2.70531177e-01 2.42073441e-02 2.71612064e-01 0.08924311 0.89612567 784.25 2.75357049e-01 -8.98947092e-03 2.75503748e-01 -0.03263501 0.88831270 784.50 2.66223167e-01 -6.96292902e-02 2.75178147e-01 -0.25581452 0.89041668 784.75 2.62640876e-01 -1.07286575e-01 2.83708722e-01 -0.38780517 0.89291569 785.00 2.50823696e-01 -1.26966078e-01 2.81127927e-01 -0.46859252 0.88616614 785.25 2.27623580e-01 -1.48285884e-01 2.71663759e-01 -0.57739543 0.87722011 785.50 1.76832937e-01 -1.86050449e-01 2.56680068e-01 -0.81079346 0.86607110 785.75 1.49167983e-01 -1.91505159e-01 2.42745367e-01 -0.90903931 0.83534141 786.00 1.14107971e-01 -1.97314348e-01 2.27933282e-01 -1.04648143 0.87858375 786.25 1.09694741e-01 -2.05119494e-01 2.32608992e-01 -1.07970982 0.87864314 786.50 8.16055795e-02 -1.95835221e-01 2.12157734e-01 -1.17597227 0.84531487 786.75 6.47468720e-02 -1.99676611e-01 2.09911663e-01 -1.25723508 0.85924887 787.00 2.83895852e-02 -2.29368950e-01 2.31119198e-01 -1.44765006 0.82928244 787.25 -2.96357305e-03 -2.15035432e-01 2.15055853e-01 -1.58457724 0.79044261 787.50 -5.55246209e-02 -2.19492174e-01 2.26406267e-01 -1.81856698 0.85414298 787.75 -9.02888218e-02 -2.05488248e-01 2.24449307e-01 -1.98478934 0.83484463 788.00 -1.15816056e-01 -1.61203673e-01 1.98494290e-01 -2.19379486 0.79307073 788.25 -1.14972089e-01 -1.39381308e-01 1.80681295e-01 -2.26052170 0.76933406 788.50 -1.22527993e-01 -1.27579790e-01 1.76888982e-01 -2.33599876 0.79019182 788.75 -1.35647981e-01 -1.14044402e-01 1.77218792e-01 -2.44250034 0.81389663 789.00 -1.50291415e-01 -8.23480516e-02 1.71373017e-01 -2.64034583 0.88235586 789.25 -1.54632711e-01 -6.88128000e-02 1.69252701e-01 -2.72289779 0.89294111 789.50 -1.36438722e-01 -4.82994463e-02 1.44735487e-01 -2.80135791 0.85123850 789.75 -1.23212910e-01 -3.29291109e-02 1.27537239e-01 -2.88044224 0.78069012 790.00 -1.17335731e-01 -4.05051252e-02 1.24130331e-01 -2.80919406 0.80029978 790.25 -1.14446315e-01 -5.11321117e-02 1.25349320e-01 -2.72142126 0.78601864 790.50 -1.39506780e-01 -6.33743122e-02 1.53226777e-01 -2.71519010 0.79263074 790.75 -1.80059188e-01 -4.51377417e-02 1.85630620e-01 -2.89597146 0.78192801 791.00 -2.33629561e-01 -2.43123448e-02 2.34891171e-01 -3.03790223 0.82982649 791.25 -2.72124823e-01 2.19649038e-02 2.73009847e-01 3.06105098 0.78921701 791.50 -2.91030941e-01 9.99807368e-02 3.07725781e-01 2.81068450 0.79739638 791.75 -2.66631635e-01 1.86421416e-01 3.25338859e-01 2.53142250 0.77123461 792.00 -2.41564859e-01 2.55115532e-01 3.51336756e-01 2.32891878 0.84367081 792.25 -1.62172983e-01 2.98112006e-01 3.39368302e-01 2.06902148 0.79615671 792.50 -1.04428239e-01 3.20760127e-01 3.37331167e-01 1.88553907 0.81803178 792.75 -2.04373711e-02 3.40643723e-01 3.41256256e-01 1.63072082 0.74653730 793.00 7.74325354e-02 3.81153419e-01 3.88939232e-01 1.37037069 0.86700811 793.25 1.45880995e-01 3.83205658e-01 4.10033951e-01 1.20705009 0.87838586 793.50 2.09443415e-01 3.62410545e-01 4.18578484e-01 1.04677219 0.87236792 793.75 3.03192560e-01 2.66266311e-01 4.03513912e-01 0.72064437 0.82153611 794.00 3.14685461e-01 1.72240797e-01 3.58739225e-01 0.50080079 0.81033622 794.25 3.24715632e-01 8.25751331e-02 3.35050585e-01 0.24902146 0.86894497 794.50 3.35443621e-01 3.48688673e-02 3.37251035e-01 0.10357653 0.90012441 794.75 3.05141629e-01 -3.77630864e-02 3.07469453e-01 -0.12312988 0.86728800 795.00 2.88287822e-01 -6.47098986e-02 2.95461062e-01 -0.22080309 0.88809125 795.25 2.62022466e-01 -1.12755155e-01 2.85253392e-01 -0.40637340 0.87124333 795.50 2.56949722e-01 -1.40741797e-01 2.92969987e-01 -0.50110690 0.89193828 795.75 2.38690533e-01 -2.07922371e-01 3.16551549e-01 -0.71661461 0.87073255 796.00 2.14094153e-01 -2.31507490e-01 3.15328438e-01 -0.82445655 0.86718210 796.25 1.91200353e-01 -2.51759781e-01 3.16133773e-01 -0.92127110 0.84449911 796.50 1.58835051e-01 -2.93697623e-01 3.33896492e-01 -1.07503499 0.86778055 796.75 1.22719995e-01 -3.41096543e-01 3.62501102e-01 -1.22543479 0.87574996 797.00 9.25389241e-02 -3.66136350e-01 3.77649678e-01 -1.32323634 0.86517193 797.25 3.39251810e-02 -4.26833735e-01 4.28179817e-01 -1.49148204 0.89826482 797.50 9.88757698e-03 -4.34992454e-01 4.35104814e-01 -1.54806978 0.87276001 797.75 -9.43997655e-02 -4.56265723e-01 4.65928885e-01 -1.77481422 0.86109852 798.00 -1.35534909e-01 -4.75041346e-01 4.93997967e-01 -1.84872385 0.87555413 798.25 -2.29608751e-01 -4.91559535e-01 5.42541201e-01 -2.00778143 0.86818022 798.50 -2.61125968e-01 -4.83208048e-01 5.49251116e-01 -2.06623978 0.87093130 798.75 -3.55727129e-01 -4.75906367e-01 5.94162150e-01 -2.21267815 0.85524695 799.00 -4.47315448e-01 -5.03734158e-01 6.73675895e-01 -2.29694136 0.83719505 799.25 -5.10094517e-01 -4.76320402e-01 6.97909407e-01 -2.39042038 0.78412232 799.50 -5.94134559e-01 -4.22993318e-01 7.29327924e-01 -2.52289237 0.69782710 799.75 -8.59621483e-01 -2.30225309e-01 8.89917293e-01 -2.87991220 0.75149724 800.00 -9.17110908e-01 -8.19369233e-02 9.20763855e-01 -3.05248680 0.63716574 800.25 -1.11266154e+00 2.75181449e-01 1.14618521e+00 2.89913963 0.58973834 800.50 -8.68711679e-01 6.52441663e-01 1.08643458e+00 2.49742301 0.51874019 800.75 -5.87738313e-01 1.05947043e+00 1.21157497e+00 2.07727696 0.61247827 801.00 -1.77538748e-01 1.07043571e+00 1.08505881e+00 1.73515666 0.57253386 801.25 6.07112254e-03 1.03223954e+00 1.03225740e+00 1.56491489 0.75448049 801.50 1.53192977e-01 8.25480520e-01 8.39574998e-01 1.38730346 0.82997730 801.75 2.24763768e-01 7.50759486e-01 7.83682689e-01 1.27990673 0.90974632 802.00 2.89722013e-01 6.18770251e-01 6.83238954e-01 1.13289252 0.91076849 802.25 2.99383866e-01 5.26427617e-01 6.05604438e-01 1.05370312 0.94174406 802.50 3.02488824e-01 4.41522404e-01 5.35202319e-01 0.97013770 0.94611940 802.75 2.96071105e-01 3.87858571e-01 4.87947098e-01 0.91880702 0.96618858 803.00 2.70716846e-01 3.13504518e-01 4.14213343e-01 0.85850643 0.94615185 803.25 2.57892598e-01 2.58474937e-01 3.65127218e-01 0.78652592 0.95955813 803.50 2.41735765e-01 2.15708373e-01 3.23985003e-01 0.72856202 0.94056586 803.75 2.21080200e-01 1.65512033e-01 2.76171483e-01 0.64263754 0.92409901 804.00 1.60456458e-01 1.25698219e-01 2.03829137e-01 0.66452370 0.88635880 804.25 1.18915018e-01 1.17644890e-01 1.67275526e-01 0.78002905 0.88255438 804.50 7.75042068e-02 1.12956856e-01 1.36989611e-01 0.96943313 0.85424793 804.75 6.13921576e-02 1.09841630e-01 1.25833941e-01 1.06113420 0.79959583 805.00 3.75679040e-02 1.21729407e-01 1.27394647e-01 1.27145185 0.77309486 805.25 1.86732121e-02 1.24532225e-01 1.25924437e-01 1.42195838 0.77443192 805.50 -2.38690109e-02 1.36461658e-01 1.38533439e-01 1.74395824 0.78708348 805.75 -4.89359817e-02 1.46926184e-01 1.54861338e-01 1.89230544 0.82778846 806.00 -9.82502563e-02 1.79792290e-01 2.04886262e-01 2.07092174 0.78834553 806.25 -1.21692341e-01 2.15409150e-01 2.47406806e-01 2.08503420 0.78505861 806.50 -1.55603288e-01 3.18423640e-01 3.54409365e-01 2.02533692 0.85829851 806.75 -1.37386889e-01 3.73222458e-01 3.97706123e-01 1.92351274 0.88908506 807.00 -7.65378952e-02 4.35536846e-01 4.42210802e-01 1.74475245 0.80935223 807.25 -2.14185242e-02 4.74621583e-01 4.75104620e-01 1.61589331 0.77971560 807.50 1.55275508e-01 4.83032819e-01 5.07376771e-01 1.25976998 0.83255029 807.75 1.93887426e-01 5.03581421e-01 5.39617069e-01 1.20327265 0.87144641 808.00 2.81311080e-01 4.85521766e-01 5.61130385e-01 1.04566197 0.87676127 808.25 3.14693730e-01 4.57999432e-01 5.55693822e-01 0.96877721 0.90285652 808.50 3.70766224e-01 3.98788166e-01 5.44517762e-01 0.82179529 0.82481112 808.75 3.86584633e-01 3.37655633e-01 5.13282578e-01 0.71794160 0.80525693 809.00 4.28099861e-01 2.46271309e-01 4.93881614e-01 0.52203419 0.80602799 809.25 3.93343264e-01 2.20174151e-01 4.50772204e-01 0.51029849 0.76115258 809.50 3.62244582e-01 1.62159272e-01 3.96883820e-01 0.42089906 0.75036473 809.75 3.47724302e-01 1.03032058e-01 3.62667610e-01 0.28806241 0.70894217 810.00 3.29961654e-01 5.87325459e-02 3.35148034e-01 0.17615318 0.76914716 810.25 3.09754298e-01 5.27483567e-02 3.14213486e-01 0.16867293 0.76279212 810.50 2.93451794e-01 5.32789527e-02 2.98249229e-01 0.17960306 0.71993482 810.75 2.96904693e-01 5.67355402e-02 3.02276890e-01 0.18881383 0.71661802 811.00 3.16535953e-01 7.23352624e-02 3.24695857e-01 0.22466369 0.74645686 811.25 3.46108974e-01 4.62009970e-02 3.49178972e-01 0.13270237 0.73247887 811.50 3.59373310e-01 -8.62245323e-03 3.59476735e-01 -0.02398842 0.71569658 811.75 3.60818702e-01 -5.03762204e-02 3.64318404e-01 -0.13871973 0.73772072 812.00 3.60218689e-01 -6.05578070e-02 3.65273530e-01 -0.16655657 0.77831528 812.25 3.56774361e-01 -8.94885531e-02 3.67826244e-01 -0.24575663 0.78552706 812.50 3.37426830e-01 -1.28807835e-01 3.61176306e-01 -0.36466274 0.82102070 812.75 3.28437532e-01 -1.88514411e-01 3.78693670e-01 -0.52106243 0.83822261 813.00 3.08138603e-01 -2.17149048e-01 3.76965658e-01 -0.61388155 0.86544716 813.25 2.67957393e-01 -1.85117039e-01 3.25683102e-01 -0.60455524 0.82893742 813.50 2.53975422e-01 -1.74775867e-01 3.08301993e-01 -0.60273575 0.88734118 813.75 2.86352695e-01 -1.84888637e-01 3.40854330e-01 -0.57332351 0.88189298 814.00 3.11623486e-01 -1.83631097e-01 3.61703714e-01 -0.53249416 0.84742755 814.25 3.22150805e-01 -2.03565084e-01 3.81077269e-01 -0.56354128 0.74698717 814.50 3.11345101e-01 -2.39067851e-01 3.92541984e-01 -0.65483064 0.75373100 814.75 3.34728088e-01 -2.73217967e-01 4.32077482e-01 -0.68456436 0.81401809 815.00 3.65926878e-01 -3.09758812e-01 4.79429871e-01 -0.70246134 0.85791279 815.25 3.56993097e-01 -3.74300225e-01 5.17247262e-01 -0.80906021 0.83423919 815.50 3.55943499e-01 -4.68801240e-01 5.88617344e-01 -0.92139312 0.79365321 815.75 3.28998380e-01 -5.90811140e-01 6.76237930e-01 -1.06270250 0.74947754 816.00 2.07526920e-01 -6.41400840e-01 6.74138309e-01 -1.25787409 0.70150695 816.25 3.09296433e-02 -7.84694803e-01 7.85304130e-01 -1.53140058 0.74078831 816.50 -2.01054069e-02 -8.32500530e-01 8.32743273e-01 -1.59494226 0.78886281 816.75 -1.52901089e-01 -7.10717687e-01 7.26978937e-01 -1.78270265 0.79050218 817.00 -2.42469765e-01 -6.82720911e-01 7.24499434e-01 -1.91205360 0.80628278 817.25 -3.84162388e-01 -6.18855129e-01 7.28397152e-01 -2.12634303 0.77694018 817.50 -4.42568584e-01 -5.97975674e-01 7.43936730e-01 -2.20793860 0.78968314 817.75 -4.79284546e-01 -5.17661981e-01 7.05469775e-01 -2.31771851 0.79096450 818.00 -5.01474173e-01 -5.38693000e-01 7.35979955e-01 -2.32042817 0.77760777 818.25 -7.17893167e-01 -5.60125128e-01 9.10555192e-01 -2.47902048 0.74150035 818.50 -8.29979457e-01 -4.78777663e-01 9.58172192e-01 -2.61836553 0.76542560 818.75 -9.64851576e-01 -2.50978624e-01 9.96959795e-01 -2.88711081 0.77938455 819.00 -9.80039514e-01 -9.82725504e-02 9.84954285e-01 -3.04165265 0.80500326 819.25 -8.80328921e-01 1.67598911e-01 8.96140839e-01 2.95346190 0.81074049 819.50 -7.83410498e-01 2.92616526e-01 8.36275337e-01 2.78412347 0.79653864 819.75 -6.79737528e-01 3.83326447e-01 7.80373162e-01 2.62811526 0.86776451 820.00 -6.03003404e-01 4.00793466e-01 7.24050072e-01 2.55497916 0.84410645 820.25 -4.48530095e-01 4.02718748e-01 6.02794854e-01 2.40995926 0.81744549 820.50 -4.25508643e-01 3.87618631e-01 5.75591703e-01 2.40275869 0.80853780 820.75 -3.74447769e-01 3.88904649e-01 5.39868463e-01 2.33725808 0.88380308 821.00 -3.61724431e-01 3.94082236e-01 5.34925577e-01 2.31340834 0.88786417 821.25 -3.60152731e-01 4.06605185e-01 5.43173790e-01 2.29568550 0.92167610 821.50 -3.02580548e-01 4.21820687e-01 5.19122028e-01 2.19305233 0.90982500 821.75 -2.31703601e-01 4.11683852e-01 4.72408883e-01 2.08342828 0.86560954 822.00 -1.96885991e-01 3.73408284e-01 4.22134860e-01 2.05601910 0.87674475 822.25 -1.62159133e-01 3.29497048e-01 3.67238191e-01 2.02813730 0.92683348 822.50 -1.53684253e-01 3.15220395e-01 3.50688961e-01 2.02443070 0.91634199 822.75 -1.60170874e-01 3.02810205e-01 3.42562008e-01 2.05733331 0.92364488 823.00 -1.49506355e-01 2.78207771e-01 3.15834947e-01 2.06390742 0.89588331 823.25 -1.49439691e-01 2.63556293e-01 3.02975479e-01 2.08660701 0.89659912 823.50 -1.69638439e-01 3.00593516e-01 3.45157445e-01 2.08458620 0.92158512 823.75 -1.75773995e-01 3.39261788e-01 3.82092997e-01 2.04882459 0.94336682 824.00 -1.44650814e-01 3.76718426e-01 4.03535166e-01 1.93741300 0.95371041 824.25 -1.35085235e-01 3.93366294e-01 4.15914729e-01 1.90158675 0.97106842 824.50 -1.06027000e-01 3.94385316e-01 4.08388910e-01 1.83342773 0.97017310 824.75 -7.44479634e-02 3.91567380e-01 3.98581876e-01 1.75868191 0.96594532 825.00 -1.28923667e-02 4.00880936e-01 4.01088193e-01 1.60294534 0.94983452 825.25 3.20926212e-02 3.92677986e-01 3.93987229e-01 1.48924999 0.95351848 825.50 7.26321214e-02 3.59313351e-01 3.66580836e-01 1.37134253 0.92811293 825.75 9.87019476e-02 3.28051063e-01 3.42577837e-01 1.27853814 0.89422521 826.00 1.32603275e-01 2.88644370e-01 3.17646346e-01 1.14015276 0.88113420 826.25 1.29656004e-01 2.83042673e-01 3.11325929e-01 1.14124396 0.89395645 826.50 1.39151965e-01 2.33695690e-01 2.71987031e-01 1.03373587 0.88007177 826.75 1.45765640e-01 2.16673394e-01 2.61141688e-01 0.97859840 0.87310933 827.00 1.54331871e-01 1.63578848e-01 2.24891898e-01 0.81447668 0.76325392 827.25 1.48847323e-01 1.20022637e-01 1.91209202e-01 0.67859928 0.62396538 827.50 1.27780736e-01 5.57979472e-02 1.39432160e-01 0.41171314 0.55469640 827.75 1.11063565e-01 2.54376309e-02 1.13939407e-01 0.22515328 0.42483311 828.00 3.03299459e-02 -5.01364839e-02 5.85966947e-02 -1.02674682 0.11068530 828.25 -1.34289612e-02 -5.28942066e-02 5.45722832e-02 -1.81942661 0.10032373 828.50 -6.22346706e-02 -8.25269340e-02 1.03362706e-01 -2.21692485 0.26127681 828.75 -1.01705524e-01 -8.64310417e-02 1.33470366e-01 -2.43720508 0.34395933 829.00 -2.30004022e-01 -5.62666600e-02 2.36786375e-01 -2.90167128 0.58500149 829.25 -2.80902520e-01 4.81729846e-03 2.80943824e-01 3.12444497 0.63792639 829.50 -3.23986160e-01 1.57671134e-01 3.60315443e-01 2.68867381 0.81409622 829.75 -3.21176583e-01 2.22861862e-01 3.90924299e-01 2.53497779 0.78611229 830.00 -2.03243913e-01 3.55085417e-01 4.09137802e-01 2.09065964 0.78276829 830.25 -1.64145496e-01 3.64482350e-01 3.99738824e-01 1.99394326 0.81760586 830.50 -1.03548784e-01 3.63495738e-01 3.77957012e-01 1.84831462 0.87801906 830.75 -8.92146924e-02 3.63615237e-01 3.74399922e-01 1.81139815 0.88898080 831.00 -4.70455165e-02 3.68279884e-01 3.71272614e-01 1.69785211 0.89179599 831.25 7.92285125e-03 3.30618070e-01 3.30712987e-01 1.54683715 0.81971017 831.50 6.94911001e-02 3.14859152e-01 3.22436503e-01 1.35357333 0.86487278 831.75 6.17006916e-02 2.92184162e-01 2.98627795e-01 1.36268328 0.88367562 832.00 5.97214939e-02 2.40168151e-01 2.47482115e-01 1.32707421 0.86477132 832.25 5.49910888e-02 2.10318969e-01 2.17389256e-01 1.31505635 0.86562632 832.50 5.05247848e-02 1.97039768e-01 2.03414414e-01 1.31978522 0.85208416 832.75 4.34355345e-02 1.86507356e-01 1.91498406e-01 1.34198571 0.82165304 833.00 6.31823494e-03 1.73907292e-01 1.74022028e-01 1.53448125 0.81953242 833.25 -1.72584119e-02 1.76096732e-01 1.76940418e-01 1.66848964 0.84965862 833.50 -3.81492230e-02 1.87974000e-01 1.91806120e-01 1.77102630 0.88977654 833.75 -5.68918420e-02 2.01385586e-01 2.09267379e-01 1.84612367 0.87640429 834.00 -7.30546118e-02 2.19843227e-01 2.31663594e-01 1.89161949 0.92320251 834.25 -6.98939415e-02 2.54892279e-01 2.64301413e-01 1.83842768 0.92072347 834.50 -6.96485212e-02 2.83563957e-01 2.91992182e-01 1.81164688 0.93638563 834.75 -5.01225789e-02 2.99997716e-01 3.04156050e-01 1.73634377 0.92191112 835.00 -4.50653190e-02 3.16172439e-01 3.19367960e-01 1.71237668 0.92053633 835.25 5.58962437e-03 3.27227882e-01 3.27275619e-01 1.55371624 0.91863485 835.50 1.28160736e-02 3.45526560e-01 3.45764161e-01 1.53372189 0.95080617 835.75 3.57490337e-02 3.48448730e-01 3.50277762e-01 1.46855921 0.94224123 836.00 6.15826883e-02 3.47794375e-01 3.53204409e-01 1.39554640 0.95614292 836.25 7.44231031e-02 3.35593161e-01 3.43746372e-01 1.35256232 0.95767355 836.50 8.40663983e-02 3.37445328e-01 3.47759269e-01 1.32664044 0.94971409 836.75 1.15247182e-01 3.26021769e-01 3.45791999e-01 1.23101100 0.92793302 837.00 1.32450653e-01 3.20993463e-01 3.47246279e-01 1.17945200 0.92157907 837.25 1.54791129e-01 3.04453712e-01 3.41544077e-01 1.10043341 0.90522537 837.50 1.60484825e-01 2.70619364e-01 3.14627112e-01 1.03551917 0.91659519 837.75 1.84522535e-01 2.32071738e-01 2.96489219e-01 0.89904428 0.93997370 838.00 1.82923446e-01 2.19628825e-01 2.85828284e-01 0.87632837 0.92490793 838.25 1.51282844e-01 1.72853975e-01 2.29706324e-01 0.85184964 0.87072542 838.50 1.39492867e-01 1.45100785e-01 2.01277167e-01 0.80510061 0.85310048 838.75 1.05920707e-01 1.22119348e-01 1.61654976e-01 0.85631324 0.79401733 839.00 8.55640095e-02 1.25572564e-01 1.51952850e-01 0.97266914 0.72312468 839.25 1.63242031e-04 1.30988869e-01 1.30988971e-01 1.56955010 0.63740605 839.50 -1.21141684e-02 1.44867345e-01 1.45372971e-01 1.65422472 0.71337326 839.75 -5.74849094e-02 1.87966431e-01 1.96560154e-01 1.86758892 0.73327507 840.00 -7.46094204e-02 2.25676690e-01 2.37689996e-01 1.89008769 0.82943906 840.25 -4.56690720e-02 2.98312372e-01 3.01787898e-01 1.72270831 0.87193278 840.50 -2.25068254e-02 3.26143990e-01 3.26919653e-01 1.63969595 0.90267700 840.75 -1.36023143e-02 3.54274583e-01 3.54535616e-01 1.60917231 0.93555721 841.00 -1.37229085e-02 3.66950630e-01 3.67207139e-01 1.60817606 0.90718836 841.25 2.94138721e-02 3.61869255e-01 3.63062713e-01 1.48969148 0.88189563 841.50 6.27150929e-02 3.83808726e-01 3.88898857e-01 1.40882581 0.89943293 841.75 8.71908769e-02 4.21624532e-01 4.30545579e-01 1.36687339 0.94262844 842.00 9.59106235e-02 4.30457699e-01 4.41013240e-01 1.35156657 0.95314227 842.25 1.18533418e-01 4.26223778e-01 4.42399006e-01 1.29954909 0.93804634 842.50 1.65935743e-01 4.15932468e-01 4.47810774e-01 1.19119652 0.93254730 842.75 1.94658756e-01 4.22222763e-01 4.64934504e-01 1.13880508 0.95487953 843.00 1.84141291e-01 4.23009164e-01 4.61351024e-01 1.16022320 0.90263730 843.25 2.21535366e-01 4.37646611e-01 4.90522654e-01 1.10220348 0.89926101 843.50 2.63701555e-01 4.67050402e-01 5.36353045e-01 1.05680509 0.92809083 843.75 3.02359134e-01 4.64207980e-01 5.53994670e-01 0.99347679 0.95541373 844.00 3.57657574e-01 4.29882597e-01 5.59211934e-01 0.87685198 0.94641669 844.25 4.35347190e-01 4.06634379e-01 5.95716958e-01 0.75130990 0.96127094 844.50 4.95688216e-01 3.64398629e-01 6.15217984e-01 0.63392058 0.92646151 844.75 5.58971544e-01 3.21680618e-01 6.44924497e-01 0.52219988 0.92394321 845.00 5.96419488e-01 2.31334562e-01 6.39712346e-01 0.37000789 0.91421255 845.25 5.93640401e-01 1.71067708e-01 6.17796962e-01 0.28056600 0.93726635 845.50 6.10756825e-01 1.17168098e-01 6.21894093e-01 0.18953804 0.89079071 845.75 5.89732770e-01 7.17913424e-02 5.94086473e-01 0.12113932 0.87536115 846.00 5.65618003e-01 -1.59156443e-02 5.65841880e-01 -0.02813108 0.85875625 846.25 5.52730191e-01 -9.53939241e-02 5.60901654e-01 -0.17090320 0.85827477 846.50 4.52894071e-01 -1.63642490e-01 4.81551559e-01 -0.34672912 0.81955099 846.75 4.24098786e-01 -2.01186843e-01 4.69399537e-01 -0.44294786 0.83215909 847.00 3.60922706e-01 -2.35425896e-01 4.30918267e-01 -0.57798265 0.71335090 847.25 2.90909839e-01 -2.50946663e-01 3.84191049e-01 -0.71177913 0.64915368 847.50 2.50000772e-01 -2.24245528e-01 3.35836929e-01 -0.73114372 0.63176803 847.75 2.03873190e-01 -2.44908026e-01 3.18660037e-01 -0.87658079 0.59903970 848.00 1.52840443e-01 -1.96678924e-01 2.49083922e-01 -0.91017164 0.47907535 848.25 1.13637387e-01 -1.55346732e-01 1.92473538e-01 -0.93923548 0.37718937 848.50 4.27138608e-02 -1.55028952e-01 1.60805627e-01 -1.30194504 0.29463862 848.75 7.11461813e-03 -1.47472657e-01 1.47644174e-01 -1.52259006 0.28060212 849.00 -1.93439506e-02 -6.74865337e-02 7.02041356e-02 -1.84994629 0.09076315 849.25 -2.49093666e-03 -3.96790047e-02 3.97571148e-02 -1.63349125 0.02929823 849.50 -1.20656043e-02 1.91559034e-02 2.26390689e-02 2.13288535 0.00595882 849.75 4.72415482e-02 8.14148231e-02 9.41283023e-02 1.04502000 0.13748390 850.00 1.22974353e-01 9.36341806e-02 1.54564068e-01 0.65076504 0.54205856 850.25 1.30473758e-01 8.28532439e-02 1.54557632e-01 0.56577118 0.53140786 850.50 1.41247143e-01 5.04744316e-02 1.49994746e-01 0.34320616 0.63833065 850.75 1.63217904e-01 3.89706008e-02 1.67805816e-01 0.23437621 0.66652685 851.00 1.26572174e-01 1.85771041e-02 1.27928199e-01 0.14573036 0.49947942 851.25 1.14452361e-01 2.63314051e-04 1.14452664e-01 0.00230064 0.51206743 851.50 9.95546582e-02 -2.55021336e-02 1.02769104e-01 -0.25076986 0.50299571 851.75 9.59550251e-02 -1.87684185e-02 9.77733111e-02 -0.19315737 0.47169989 852.00 9.04671437e-02 -2.31126698e-03 9.04966631e-02 -0.02554258 0.54206598 852.25 9.45145712e-02 -8.98810539e-03 9.49409828e-02 -0.09481244 0.54543384 852.50 1.06679529e-01 3.20372603e-04 1.06680011e-01 0.00300312 0.64515922 852.75 1.12110079e-01 -1.58577135e-03 1.12121294e-01 -0.01414383 0.62929039 853.00 1.24539511e-01 -1.30533385e-02 1.25221721e-01 -0.10443152 0.61852927 853.25 1.16551140e-01 -3.53943128e-02 1.21806920e-01 -0.29483000 0.60563536 853.50 1.10789780e-01 -5.22205316e-02 1.22480036e-01 -0.44046435 0.60491209 853.75 1.02906974e-01 -6.67735015e-02 1.22672515e-01 -0.57558216 0.62708086 854.00 8.34317291e-02 -6.66059725e-02 1.06757712e-01 -0.67372124 0.56130161 854.25 6.53907478e-02 -7.09851019e-02 9.65133907e-02 -0.82639677 0.46938538 854.50 5.53654325e-02 -6.90928063e-02 8.85389576e-02 -0.89525116 0.50827334 854.75 5.06592229e-02 -5.14238924e-02 7.21856881e-02 -0.79288868 0.42744338 855.00 3.94172174e-02 -4.16578862e-02 5.73506453e-02 -0.81302808 0.37255921 855.25 3.27668055e-02 -3.72932395e-02 4.96432196e-02 -0.84991642 0.39611480 855.50 3.09990625e-02 -3.49604341e-02 4.67244458e-02 -0.84538375 0.37980690 855.75 8.20468232e-03 -5.64905971e-02 5.70833108e-02 -1.42656506 0.36877289 856.00 -6.81809384e-03 -6.53841414e-02 6.57386671e-02 -1.67469829 0.45640763 856.25 -2.58606358e-02 -6.45678028e-02 6.95541058e-02 -1.95175009 0.42365490 856.50 -4.95565076e-02 -6.63207010e-02 8.27905963e-02 -2.21251928 0.48065182 856.75 -8.71168271e-02 -5.20442249e-02 1.01478781e-01 -2.60308176 0.59004154 857.00 -1.08399674e-01 -3.85291487e-02 1.15043403e-01 -2.80008329 0.69798197 857.25 -1.34110158e-01 -1.21382852e-02 1.34658355e-01 -3.05132879 0.65802657 857.50 -1.50107902e-01 1.68590133e-02 1.51051675e-01 3.02974872 0.68912713 857.75 -1.58170058e-01 7.82556036e-02 1.76470130e-01 2.68214895 0.69510066 858.00 -1.54838183e-01 1.28133713e-01 2.00980376e-01 2.45028728 0.78014991 858.25 -1.21832781e-01 1.54564558e-01 1.96808102e-01 2.23832056 0.85370436 858.50 -9.67874946e-02 1.49042843e-01 1.77712093e-01 2.14674526 0.86605964 858.75 -7.20659666e-02 1.37233025e-01 1.55004537e-01 2.05434974 0.83248814 859.00 -6.32693270e-02 1.21948126e-01 1.37383963e-01 2.04938762 0.78497406 859.25 -7.65157220e-02 1.15398999e-01 1.38461492e-01 2.15629340 0.76337315 859.50 -9.70522849e-02 1.18297589e-01 1.53014593e-01 2.25785787 0.80153332 859.75 -1.37843906e-01 1.16806930e-01 1.80678724e-01 2.43861839 0.82393725 860.00 -1.53845888e-01 1.30653317e-01 2.01838665e-01 2.43753531 0.83989841 860.25 -1.44887685e-01 1.75324582e-01 2.27444829e-01 2.26142696 0.87450336 860.50 -1.27868386e-01 1.99284304e-01 2.36779556e-01 2.14127070 0.87896914 860.75 -1.05579875e-01 2.37742414e-01 2.60131824e-01 1.98872761 0.95205287 861.00 -9.02508880e-02 2.48318391e-01 2.64210610e-01 1.91940119 0.96232840 861.25 -6.49118725e-02 2.60490919e-01 2.68456831e-01 1.81501300 0.95702196 861.50 -5.96872968e-02 2.62305086e-01 2.69010282e-01 1.79453575 0.95174453 861.75 -4.19845625e-02 2.55496733e-01 2.58923317e-01 1.73366600 0.94940192 862.00 -3.56116863e-02 2.43853045e-01 2.46439647e-01 1.71580872 0.92826642 862.25 -4.04436550e-02 2.33874264e-01 2.37345446e-01 1.74203188 0.92421057 862.50 -2.91904692e-02 2.40236738e-01 2.42003665e-01 1.69171069 0.92749006 862.75 -2.68636151e-02 2.34000855e-01 2.35537797e-01 1.68509730 0.94315022 863.00 -4.10906233e-02 2.27776606e-01 2.31453282e-01 1.74927551 0.92644063 863.25 -4.28492089e-02 2.31939371e-01 2.35864212e-01 1.75347973 0.88464071 863.50 -5.84034669e-02 2.38998161e-01 2.46030661e-01 1.81046716 0.88107954 863.75 -6.90578170e-02 2.58026381e-01 2.67107834e-01 1.83230590 0.90313315 864.00 -7.09006820e-02 2.81912358e-01 2.90691390e-01 1.81718533 0.91966647 864.25 -7.98021522e-02 3.10542446e-01 3.20632179e-01 1.82233038 0.92914168 864.50 -7.81099938e-02 3.25310165e-01 3.34556235e-01 1.80644465 0.92214153 864.75 -7.21291367e-02 3.36841640e-01 3.44477725e-01 1.78174429 0.92320738 865.00 -6.00444516e-02 3.50902591e-01 3.56002760e-01 1.74026929 0.91022527 865.25 -5.49384613e-02 3.82109859e-01 3.86039090e-01 1.71359435 0.92554305 865.50 -3.78206113e-02 3.98642555e-01 4.00432622e-01 1.66538670 0.94572757 865.75 -3.85946470e-02 4.00356636e-01 4.02212609e-01 1.66690003 0.94907054 866.00 -2.61324902e-02 4.32082203e-01 4.32871733e-01 1.63120311 0.94000865 866.25 -2.01190053e-02 4.60668582e-01 4.61107707e-01 1.61444208 0.94046387 866.50 1.87641998e-02 4.95547021e-01 4.95902153e-01 1.53294878 0.93490116 866.75 5.55791537e-02 5.17214369e-01 5.20192028e-01 1.46374846 0.93497785 867.00 1.17888969e-01 5.37550577e-01 5.50325751e-01 1.35490648 0.94599326 867.25 1.44320540e-01 5.35889637e-01 5.54982992e-01 1.30772754 0.94769367 867.50 1.93547276e-01 5.21714500e-01 5.56458954e-01 1.21555194 0.94521240 867.75 2.20804757e-01 5.23512650e-01 5.68172716e-01 1.17166011 0.94790990 868.00 2.67882818e-01 4.87490017e-01 5.56244300e-01 1.06832596 0.95173422 868.25 2.70033889e-01 4.74065498e-01 5.45578956e-01 1.05301992 0.96263554 868.50 3.05210407e-01 4.34312535e-01 5.30830265e-01 0.95823131 0.94707582 868.75 3.21163411e-01 4.23513854e-01 5.31516623e-01 0.92198508 0.94158840 869.00 3.31059396e-01 4.12750271e-01 5.29115403e-01 0.89478741 0.92168288 869.25 3.31227088e-01 3.97921364e-01 5.17738153e-01 0.87661307 0.91656649 869.50 3.35392033e-01 4.29904180e-01 5.45257205e-01 0.90827347 0.91872196 869.75 3.58775094e-01 4.22998783e-01 5.54659840e-01 0.86736534 0.90523945 870.00 3.70241370e-01 4.07574734e-01 5.50632214e-01 0.83335903 0.85545843 870.25 3.91154884e-01 3.82586438e-01 5.47151283e-01 0.77432457 0.81652297 870.50 4.18956650e-01 2.95193229e-01 5.12507285e-01 0.61380076 0.77060839 870.75 3.78522847e-01 2.49896375e-01 4.53572204e-01 0.58350420 0.72314738 871.00 3.81373128e-01 2.32820398e-01 4.46823009e-01 0.54808925 0.78022257 871.25 4.32029221e-01 2.32526442e-01 4.90629997e-01 0.49375352 0.83566995 871.50 4.59103115e-01 1.68424982e-01 4.89022131e-01 0.35161216 0.87704321 871.75 4.12978685e-01 1.11862121e-01 4.27860408e-01 0.26451935 0.84934075 872.00 3.34748639e-01 8.54142818e-02 3.45473951e-01 0.24982870 0.83630896 872.25 2.98566471e-01 8.80005189e-02 3.11265207e-01 0.28662734 0.76561436 872.50 2.08684522e-01 8.03170734e-02 2.23606936e-01 0.36739838 0.64877622 872.75 1.59943187e-01 1.12018874e-01 1.95269176e-01 0.61097199 0.60395876 873.00 1.12646040e-01 1.82777371e-01 2.14701415e-01 1.01847629 0.58335863 873.25 1.11051524e-01 2.32691368e-01 2.57832724e-01 1.12551530 0.61730572 873.50 1.83972016e-01 3.07692162e-01 3.58497098e-01 1.03191550 0.73579760 873.75 1.83083338e-01 3.32361965e-01 3.79452216e-01 1.06729672 0.72082718 874.00 2.56889400e-01 3.55646778e-01 4.38721774e-01 0.94524958 0.83422895 874.25 3.27750196e-01 3.25689420e-01 4.62053882e-01 0.78224444 0.88131818 874.50 3.58530652e-01 3.00274295e-01 4.67663213e-01 0.69720025 0.92761654 874.75 3.51544433e-01 2.65885765e-01 4.40770607e-01 0.64754393 0.90894686 875.00 3.33991280e-01 2.43291147e-01 4.13207886e-01 0.62955646 0.90645032 875.25 3.06316730e-01 2.30329217e-01 3.83251206e-01 0.64473616 0.92200349 875.50 2.74660226e-01 2.36530267e-01 3.62470422e-01 0.71094553 0.93664452 875.75 2.55030670e-01 2.27556530e-01 3.41793237e-01 0.72852862 0.91445720 876.00 2.23540147e-01 2.29655700e-01 3.20487032e-01 0.79889163 0.89661053 876.25 2.23343097e-01 2.60897348e-01 3.43437862e-01 0.86279614 0.90750703 876.50 2.20411988e-01 2.91132950e-01 3.65157280e-01 0.92277709 0.90574797 876.75 1.85271777e-01 3.19666751e-01 3.69475930e-01 1.04552846 0.84074676 877.00 1.70820204e-01 3.57260852e-01 3.95998559e-01 1.12479029 0.83607980 877.25 1.61181981e-01 3.67242441e-01 4.01056905e-01 1.15721307 0.77961588 877.50 1.70501127e-01 3.65012552e-01 4.02870696e-01 1.13380492 0.73339980 877.75 1.51193158e-01 3.94955752e-01 4.22905920e-01 1.20519585 0.65366759 878.00 1.57001681e-01 4.15130521e-01 4.43827532e-01 1.20922457 0.68118790 878.25 1.85011973e-01 4.72551252e-01 5.07478192e-01 1.19762397 0.60333139 878.50 1.79630527e-01 4.87273882e-01 5.19329339e-01 1.21760977 0.50703579 878.75 1.04972960e-01 3.08009112e-01 3.25405801e-01 1.24233084 0.31308775 879.00 8.48935510e-02 2.40634518e-01 2.55170308e-01 1.23163778 0.22484104 879.25 6.72182596e-02 2.07899643e-01 2.18496123e-01 1.25808404 0.17105692 879.50 2.02332455e-02 1.70945404e-01 1.72138652e-01 1.45298358 0.10559818 879.75 -1.34454725e-01 9.74586473e-03 1.34807474e-01 3.06923484 0.07234182 880.00 -1.61908369e-01 -2.77038405e-02 1.64261446e-01 -2.97212568 0.11306756 880.25 -9.51806766e-02 -6.37595491e-02 1.14562827e-01 -2.55136933 0.10607159 880.50 -8.61737260e-02 -7.81228060e-02 1.16314590e-01 -2.40515770 0.11799107 880.75 -7.52605997e-02 -1.02148000e-01 1.26879359e-01 -2.20578279 0.11603217 881.00 -2.36766311e-02 -1.01653792e-01 1.04374692e-01 -1.79963091 0.09191675 881.25 -2.40303227e-02 -9.75353139e-02 1.00451948e-01 -1.81236090 0.14314891 881.50 -8.24286903e-03 -9.31798169e-02 9.35436966e-02 -1.65902861 0.16087873 881.75 2.02121028e-03 -4.22637921e-02 4.23120953e-02 -1.52300905 0.03941168 882.00 -1.70700412e-02 -3.20042620e-02 3.62720153e-02 -2.06078045 0.03666224 882.25 -9.20988363e-03 -2.58110340e-02 2.74049527e-02 -1.91353358 0.02951421 882.50 1.66029518e-03 -1.10699610e-02 1.11937758e-02 -1.42192396 0.00494689 882.75 5.25357760e-02 2.02997940e-02 5.63213050e-02 0.36872705 0.07972950 883.00 7.65615853e-02 4.37003549e-02 8.81555294e-02 0.51866231 0.17497947 883.25 6.56197754e-02 8.41226090e-02 1.06689120e-01 0.90833943 0.28865155 883.50 7.49285621e-02 1.08080468e-01 1.31513030e-01 0.96460384 0.31417179 883.75 5.01908594e-02 1.16715921e-01 1.27050103e-01 1.16467648 0.20778532 884.00 1.02425208e-01 1.73564167e-01 2.01532735e-01 1.03766670 0.29457562 884.25 2.03021043e-01 1.65696896e-01 2.62055348e-01 0.68451498 0.40972451 884.50 2.29029293e-01 3.70567887e-02 2.32007807e-01 0.16040920 0.32115039 884.75 2.59490551e-01 4.46595388e-02 2.63305565e-01 0.17043501 0.34240800 885.00 2.83326754e-01 3.93754453e-02 2.86049778e-01 0.13809088 0.32105419 885.25 2.59937380e-01 1.73702743e-02 2.60517117e-01 0.06672564 0.30807254 885.50 2.84404147e-01 -1.16948050e-02 2.84644493e-01 -0.04109722 0.45195462 885.75 3.32927328e-01 7.23648633e-03 3.33005964e-01 0.02173251 0.56940796 886.00 3.30861125e-01 -6.64180268e-02 3.37461758e-01 -0.19810980 0.53372668 886.25 3.34990590e-01 -6.11750364e-02 3.40530587e-01 -0.18062682 0.55037208 886.50 2.39153411e-01 2.41363031e-02 2.40368290e-01 0.10058336 0.41516248 886.75 2.10829603e-01 1.04522325e-01 2.35316888e-01 0.46025534 0.33706315 887.00 2.46296667e-01 1.83671476e-01 3.07241370e-01 0.64076443 0.34129534 887.25 2.61205516e-01 2.44991059e-01 3.58118612e-01 0.75337717 0.36958947 887.50 3.47240561e-01 1.93808611e-01 3.97665418e-01 0.50907073 0.43012634 887.75 3.97632608e-01 1.19262534e-01 4.15132802e-01 0.29139392 0.47559037 888.00 3.77517879e-01 9.55133626e-02 3.89413085e-01 0.24780353 0.54903584 888.25 3.24543173e-01 9.42454235e-02 3.37950397e-01 0.28262091 0.43942574 888.50 1.84357952e-01 1.44672170e-01 2.34345666e-01 0.66536357 0.29656162 888.75 1.92363100e-01 1.16014509e-01 2.24639552e-01 0.54269703 0.30964060 889.00 1.11433477e-01 1.70448818e-01 2.03642381e-01 0.99177889 0.30960393 889.25 8.74124081e-02 1.83157334e-01 2.02947131e-01 1.12551126 0.33851769 889.50 -7.08154073e-03 1.38950011e-01 1.39130348e-01 1.62171693 0.18856728 889.75 -7.02487731e-02 1.34412800e-01 1.51663083e-01 2.05238718 0.30600772 890.00 -8.38207672e-02 1.77106524e-01 1.95940404e-01 2.01283940 0.44943688 890.25 -8.16697233e-02 1.47769050e-01 1.68836121e-01 2.07569855 0.33780883 890.50 -7.36141216e-02 1.35192379e-01 1.53935110e-01 2.06941776 0.29965401 890.75 -3.58429574e-02 1.30637713e-01 1.35465603e-01 1.83857594 0.24242113 891.00 5.84835177e-03 9.79490521e-02 9.81234937e-02 1.51115903 0.17905895 891.25 1.59476370e-02 8.81763227e-02 8.96068692e-02 1.39186976 0.18545603 891.50 6.32554512e-02 3.88638146e-02 7.42404754e-02 0.55093666 0.14519598 891.75 8.11720594e-02 6.50441454e-03 8.14322457e-02 0.07996035 0.20094610 892.00 5.56555117e-02 -1.58656276e-02 5.78727407e-02 -0.27770242 0.15612892 892.25 4.13831503e-02 -1.23019713e-02 4.31729502e-02 -0.28895038 0.08354534 892.50 2.22806956e-03 -1.88656840e-03 2.91949213e-03 -0.70259130 0.00045507 892.75 -1.09546189e-02 6.54557512e-03 1.27612002e-02 2.60300061 0.00812464 893.00 -5.33327149e-02 4.64211662e-02 7.07057505e-02 2.42536995 0.23793530 893.25 -8.58545900e-02 8.19390898e-02 1.18680348e-01 2.37952546 0.38329646 893.50 -1.07299777e-01 1.05650317e-01 1.50582973e-01 2.36394010 0.53263692 893.75 -1.33174196e-01 1.39287902e-01 1.92708293e-01 2.33375952 0.61482820 894.00 -1.82878727e-01 2.22631739e-01 2.88113728e-01 2.25847470 0.76079855 894.25 -1.95696375e-01 2.52322204e-01 3.19317344e-01 2.23046944 0.74785926 894.50 -1.98139468e-01 3.01650376e-01 3.60904694e-01 2.15197292 0.71009199 894.75 -2.27286688e-01 3.62410503e-01 4.27785707e-01 2.13094208 0.69155983 895.00 -2.14337990e-01 4.31319883e-01 4.81640546e-01 2.03198901 0.64721465 895.25 -1.41198104e-01 4.79214216e-01 4.99582995e-01 1.85733312 0.56350382 895.50 -2.00753313e-01 5.65694504e-01 6.00260081e-01 1.91181140 0.56884690 895.75 -2.95989236e-01 8.33778048e-01 8.84757290e-01 1.91191643 0.70542416 896.00 -2.81646147e-01 1.00796906e+00 1.04657832e+00 1.84326659 0.80619437 896.25 -1.18501381e-01 1.03641594e+00 1.04316852e+00 1.68463962 0.76375839 896.50 -7.96160100e-02 1.02532162e+00 1.02840806e+00 1.64829062 0.77679376 896.75 6.62266184e-03 9.00037834e-01 9.00062199e-01 1.56343826 0.65863387 897.00 4.28046725e-02 9.14623956e-01 9.15625044e-01 1.52403015 0.65446191 897.25 1.24061133e-01 1.08260346e+00 1.08968868e+00 1.45669886 0.75172638 897.50 2.55117092e-01 1.10704102e+00 1.13605658e+00 1.34430103 0.72760619 897.75 4.89137757e-01 9.03969385e-01 1.02782119e+00 1.07481186 0.65063097 898.00 5.69238497e-01 8.85768183e-01 1.05290918e+00 0.99960577 0.69349620 898.25 6.19215334e-01 6.65978179e-01 9.09370422e-01 0.82176796 0.55595376 898.50 6.02421300e-01 4.43569715e-01 7.48107956e-01 0.63468274 0.41021796 898.75 5.72812989e-01 3.26540561e-01 6.59350786e-01 0.51811749 0.35508845 899.00 6.18273743e-01 3.74933381e-01 7.23075004e-01 0.54512651 0.46306790 899.25 6.26214078e-01 1.45204501e-01 6.42828452e-01 0.22785014 0.37602434 899.50 5.48007991e-01 1.27518663e-01 5.62648885e-01 0.22862638 0.33973610 899.75 3.90053311e-01 8.89072349e-02 4.00057599e-01 0.22410731 0.21858994 900.00 3.47930853e-01 -1.32840417e-01 3.72427785e-01 -0.36471999 0.19348332 900.25 3.98712184e-01 -2.89467526e-01 4.92709706e-01 -0.62796742 0.33229965 900.50 3.72731276e-01 -3.06820054e-01 4.82770287e-01 -0.68870835 0.32372655 900.75 1.63282367e-01 -3.96614622e-01 4.28910584e-01 -1.18025296 0.25311058 901.00 1.14609874e-01 -2.95770606e-01 3.17199739e-01 -1.20111567 0.14386851 901.25 1.45285277e-02 -2.66488210e-01 2.66883952e-01 -1.51633178 0.14216773 901.50 -1.71989234e-02 -2.60209682e-01 2.60777456e-01 -1.63679673 0.20490761 901.75 -8.54336591e-02 -2.08101962e-01 2.24956300e-01 -1.96035362 0.17964186 902.00 -1.53546021e-01 -1.62067842e-01 2.23254039e-01 -2.32920027 0.22207589 902.25 -2.01641729e-01 -1.76607506e-01 2.68047754e-01 -2.42228257 0.33465445 902.50 -1.74962331e-01 -1.76343527e-01 2.48412674e-01 -2.35226291 0.30189302 902.75 -1.96330395e-01 -1.65081614e-01 2.56510357e-01 -2.44244303 0.40329137 903.00 -2.22160365e-01 -1.70451088e-01 2.80015716e-01 -2.48714676 0.45551072 903.25 -2.51785922e-01 -1.27930241e-01 2.82422197e-01 -2.67149296 0.62734314 903.50 -2.47335525e-01 -1.04766995e-01 2.68609354e-01 -2.74092327 0.69478198 903.75 -2.39268429e-01 -1.24526265e-01 2.69733520e-01 -2.66172246 0.70181102 904.00 -2.12085149e-01 -1.44784324e-01 2.56792933e-01 -2.54259200 0.70690740 904.25 -1.83910767e-01 -1.31412666e-01 2.26036411e-01 -2.52117097 0.74513845 904.50 -1.89912132e-01 -1.21609633e-01 2.25511687e-01 -2.57203345 0.81405286 904.75 -2.08302040e-01 -1.09992737e-01 2.35559212e-01 -2.65576201 0.82846129 905.00 -1.96525199e-01 -1.14738199e-01 2.27567590e-01 -2.61314433 0.77385591 905.25 -2.03844672e-01 -8.04938084e-02 2.19161820e-01 -2.76550944 0.82076099 905.50 -2.10086447e-01 -6.62502064e-02 2.20284827e-01 -2.83611586 0.86368173 905.75 -2.00042547e-01 -5.93113745e-02 2.08650089e-01 -2.85335565 0.88622217 906.00 -1.84380507e-01 -5.41937618e-02 1.92179955e-01 -2.85571992 0.85854671 906.25 -1.84796421e-01 -4.32577401e-02 1.89791858e-01 -2.91164968 0.87058265 906.50 -1.72200235e-01 -2.16113682e-02 1.73551065e-01 -3.01674402 0.82954196 906.75 -1.71369108e-01 -1.13658628e-02 1.71745608e-01 -3.07536577 0.83959020 907.00 -1.56776830e-01 9.94386110e-03 1.57091868e-01 3.07825065 0.71168376 907.25 -1.46833627e-01 1.78073838e-02 1.47909489e-01 3.02090611 0.66649556 907.50 -1.12930507e-01 4.75568753e-02 1.22535529e-01 2.74301614 0.64396470 907.75 -9.64610717e-02 5.96981540e-02 1.13439887e-01 2.58740390 0.68498703 908.00 -6.85004406e-02 6.54604945e-02 9.47490723e-02 2.37888338 0.61451278 908.25 -4.94441601e-02 6.91000521e-02 8.49678891e-02 2.19187882 0.58803393 908.50 -2.41806705e-02 5.70856735e-02 6.19957978e-02 1.97146837 0.39052507 908.75 -7.09015744e-03 3.64146162e-02 3.70984447e-02 1.76309671 0.19567248 909.00 1.62529252e-02 4.22714518e-03 1.67936396e-02 0.25444786 0.04670111 909.25 2.13279423e-02 -8.44959549e-03 2.29407233e-02 -0.37720454 0.12423685 909.50 2.82539814e-02 -2.49420977e-02 3.76881374e-02 -0.72322037 0.27935319 909.75 2.60462404e-02 -3.29912540e-02 4.20336708e-02 -0.90249732 0.34524017 910.00 1.21842985e-02 -3.41324297e-02 3.62419630e-02 -1.22792453 0.28131294 910.25 1.14808040e-02 -3.80027994e-02 3.96991388e-02 -1.27741022 0.32274019 910.50 1.21241467e-02 -5.95579894e-02 6.07795116e-02 -1.36997162 0.41869346 910.75 4.59875214e-03 -6.84607904e-02 6.86150738e-02 -1.50372357 0.45108910 911.00 -1.43937969e-02 -6.25345450e-02 6.41697024e-02 -1.79702952 0.47406478 911.25 -1.89752042e-02 -6.03068859e-02 6.32216645e-02 -1.87563332 0.44032002 911.50 -2.60553588e-02 -7.25626399e-02 7.70987577e-02 -1.91553192 0.41595417 911.75 -2.20407971e-02 -6.55825597e-02 6.91872016e-02 -1.89501424 0.36357299 912.00 -1.59201280e-02 -6.00137349e-02 6.20894424e-02 -1.83009875 0.30768602 912.25 -6.51702205e-03 -6.83664366e-02 6.86763513e-02 -1.66583403 0.31273985 912.50 -2.25207744e-03 -8.17667300e-02 8.17977383e-02 -1.59833208 0.33100648 912.75 -9.51355872e-03 -7.56901760e-02 7.62857165e-02 -1.69583143 0.30460435 913.00 -1.66608295e-02 -8.41347701e-02 8.57685419e-02 -1.76629261 0.23265666 913.25 -2.67504086e-02 -6.45861794e-02 6.99067874e-02 -1.96346815 0.12934544 913.50 -7.83351923e-02 -3.27285373e-03 7.84035326e-02 -3.09983682 0.19488583 913.75 -8.20826186e-02 2.18930136e-02 8.49521060e-02 2.88094118 0.19544311 914.00 -5.83611783e-02 5.53817865e-02 8.04560092e-02 2.38238258 0.18197809 914.25 -2.57736959e-02 6.83984330e-02 7.30932900e-02 1.93115908 0.16663669 914.50 2.44277801e-02 1.02177859e-01 1.05057276e-01 1.33612977 0.43412180 914.75 4.38820861e-02 9.05585098e-02 1.00630419e-01 1.11956741 0.41258585 915.00 7.91306198e-02 6.37934640e-02 1.01642811e-01 0.67849744 0.52505331 915.25 7.58728599e-02 5.75282891e-02 9.52165685e-02 0.64874093 0.49361188 915.50 6.73029680e-02 4.62640132e-02 8.16703644e-02 0.60221896 0.50142959 915.75 7.16692621e-02 3.61089765e-02 8.02517371e-02 0.46670527 0.40097869 916.00 8.58224624e-02 1.52794788e-02 8.71719997e-02 0.17618982 0.51025365 916.25 7.87127276e-02 1.74607246e-02 8.06261148e-02 0.21829370 0.43530593 916.50 6.14516436e-02 1.62924182e-02 6.35747386e-02 0.25916330 0.30584866 916.75 5.53479301e-02 2.00103527e-02 5.88541212e-02 0.34691602 0.20771916 917.00 5.70014392e-02 4.42200444e-02 7.21427501e-02 0.65979137 0.28301908 917.25 7.02588130e-02 8.32129518e-02 1.08906823e-01 0.86960587 0.38646122 917.50 1.05368078e-01 1.16262237e-01 1.56905512e-01 0.83451328 0.49724729 917.75 1.45147431e-01 1.21644392e-01 1.89380925e-01 0.69752995 0.50510548 918.00 2.03648339e-01 1.12536247e-01 2.32673705e-01 0.50483784 0.50303679 918.25 3.08159575e-01 6.27470953e-02 3.14482943e-01 0.20087278 0.63458519 918.50 3.40605445e-01 2.88678706e-02 3.41826598e-01 0.08455251 0.69121744 918.75 3.17125942e-01 -7.07550345e-02 3.24923280e-01 -0.21951799 0.62999811 919.00 3.16965287e-01 -1.25875011e-01 3.41044735e-01 -0.37802594 0.67862836 919.25 3.40196288e-01 -1.84548611e-01 3.87029333e-01 -0.49704894 0.76348323 919.50 3.21466845e-01 -1.92876554e-01 3.74889714e-01 -0.54041137 0.69997010 919.75 2.64279627e-01 -2.24454383e-01 3.46732594e-01 -0.70409127 0.68809431 920.00 2.40544571e-01 -2.49667382e-01 3.46692216e-01 -0.80400595 0.74203122 920.25 1.83180872e-01 -2.55524359e-01 3.14400906e-01 -0.94882964 0.79110475 920.50 1.67507887e-01 -2.58088957e-01 3.07682957e-01 -0.99510218 0.79672033 920.75 1.34940597e-01 -2.57352387e-01 2.90584266e-01 -1.08786550 0.75469802 921.00 1.34190888e-01 -2.66563378e-01 2.98434631e-01 -1.10442379 0.76616018 921.25 9.97657562e-02 -2.87285907e-01 3.04115765e-01 -1.23655571 0.78722025 921.50 8.14622071e-02 -2.74964702e-01 2.86778100e-01 -1.28277035 0.80454120 921.75 8.46692188e-02 -2.34132745e-01 2.48971924e-01 -1.22379929 0.73053990 922.00 9.80857046e-02 -2.44344298e-01 2.63296299e-01 -1.18906283 0.76774350 922.25 9.88598037e-02 -3.12072113e-01 3.27356479e-01 -1.26401235 0.81884258 922.50 7.48332461e-02 -3.13581029e-01 3.22386532e-01 -1.33653686 0.81439927 922.75 3.78206236e-02 -2.82254305e-01 2.84776916e-01 -1.43759489 0.75628061 923.00 1.66655564e-02 -2.74512882e-01 2.75018296e-01 -1.51016119 0.70536888 923.25 1.26880223e-02 -2.47489104e-01 2.47814129e-01 -1.51957418 0.57228354 923.50 -1.33344486e-02 -2.53305405e-01 2.53656137e-01 -1.62338957 0.57697331 923.75 -5.62293173e-02 -2.63761006e-01 2.69687976e-01 -1.78083496 0.66800248 924.00 -7.66938118e-02 -2.71014319e-01 2.81657064e-01 -1.84657369 0.71724437 924.25 -1.01380377e-01 -2.55248707e-01 2.74645013e-01 -1.94887166 0.65772374 924.50 -8.39299296e-02 -2.73656229e-01 2.86237602e-01 -1.86838706 0.62408222 924.75 -6.75258554e-02 -2.27517691e-01 2.37326865e-01 -1.85930913 0.49635950 925.00 -7.87893257e-02 -2.24769469e-01 2.38178656e-01 -1.90794673 0.49000731 925.25 -8.57752914e-02 -1.83344055e-01 2.02416509e-01 -2.00838481 0.43617235 925.50 -8.41038716e-02 -1.55688339e-01 1.76952876e-01 -2.06608955 0.41312037 925.75 -3.94902699e-02 -1.42508444e-01 1.47878795e-01 -1.84112153 0.31334584 926.00 -5.66559539e-02 -1.38133637e-01 1.49301034e-01 -1.96002471 0.30079471 926.25 -1.08182483e-01 -1.41898698e-01 1.78433994e-01 -2.22218148 0.35044592 926.50 -8.45348584e-02 -1.41416177e-01 1.64756418e-01 -2.10957717 0.29260620 926.75 -6.68471864e-02 -1.37494171e-01 1.52882940e-01 -2.02332853 0.34656533 927.00 -6.30011494e-02 -1.38650890e-01 1.52293185e-01 -1.99729241 0.34904151 927.25 -3.30275738e-02 -1.54263478e-01 1.57759441e-01 -1.78171062 0.39157710 927.50 -2.82120684e-02 -1.39683522e-01 1.42504060e-01 -1.77008669 0.26097016 927.75 -1.66656312e-02 -1.24816598e-01 1.25924288e-01 -1.70353220 0.21069892 928.00 5.31459582e-02 -1.11520359e-01 1.23536566e-01 -1.12607728 0.24363359 928.25 5.76614941e-02 -1.20345859e-01 1.33446520e-01 -1.12398244 0.33421925 928.50 5.05452754e-02 -1.70773343e-01 1.78096489e-01 -1.28303285 0.45147871 928.75 5.24600021e-02 -2.14324076e-01 2.20650995e-01 -1.33074649 0.54238050 929.00 1.26539928e-02 -2.48970961e-01 2.49292324e-01 -1.52001485 0.48462467 929.25 -6.89035066e-03 -2.81177266e-01 2.81261679e-01 -1.59529679 0.50010735 929.50 -4.73957113e-02 -3.29816768e-01 3.33204823e-01 -1.71352238 0.52550175 929.75 -1.34241915e-01 -3.87942469e-01 4.10512182e-01 -1.90393505 0.54141767 930.00 -2.32282438e-01 -3.20237638e-01 3.95610005e-01 -2.19832994 0.52804018 930.25 -2.87855126e-01 -2.89083956e-01 4.07958463e-01 -2.35406458 0.51122872 930.50 -2.75640496e-01 -2.25311625e-01 3.56009847e-01 -2.45632493 0.46051820 930.75 -2.68191926e-01 -1.75058770e-01 3.20269390e-01 -2.56329582 0.41522710 931.00 -2.22043354e-01 -7.32447979e-02 2.33812000e-01 -2.82296494 0.23827179 931.25 -2.58984113e-01 -9.20041277e-03 2.59147483e-01 -3.10608258 0.25844599 931.50 -3.53494404e-01 1.31542680e-01 3.77176047e-01 2.78534845 0.28245567 931.75 -1.93617928e-01 2.57055947e-01 3.21816192e-01 2.21635070 0.16166320 932.00 1.52543100e-01 2.12003584e-01 2.61179856e-01 0.94708238 0.10964192 932.25 2.05520619e-01 8.09287077e-02 2.20880467e-01 0.37512777 0.07889910 932.50 3.32613386e-01 7.63761259e-02 3.41269655e-01 0.22571156 0.21875307 932.75 3.14978295e-01 1.15450224e-02 3.15189807e-01 0.03663699 0.22660811 933.00 3.46149336e-01 -8.40390798e-02 3.56204899e-01 -0.23817449 0.27791910 933.25 3.01398341e-01 -1.95963240e-01 3.59503201e-01 -0.57650190 0.24360388 933.50 9.79807337e-02 -4.24866454e-01 4.36018036e-01 -1.34414357 0.33407391 933.75 8.45167855e-02 -3.86691346e-01 3.95819763e-01 -1.35561619 0.25807245 934.00 -2.64327041e-02 -2.17202969e-01 2.18805434e-01 -1.69189671 0.09802073 934.25 -6.88745205e-02 -2.20241436e-01 2.30759593e-01 -1.87388417 0.13816832 934.50 -1.30620395e-01 -3.91615151e-01 4.12824556e-01 -1.89273534 0.24593866 934.75 -1.61269192e-01 -4.02335601e-01 4.33453213e-01 -1.95202019 0.28825765 935.00 -1.30443736e-01 -4.12181289e-01 4.32329716e-01 -1.87729549 0.29112131 935.25 -1.24891480e-01 -4.34719274e-01 4.52303802e-01 -1.85055425 0.29479656 935.50 -1.44711195e-01 -4.42588823e-01 4.65645999e-01 -1.88680476 0.38931955 935.75 -2.33965682e-01 -4.30369526e-01 4.89854947e-01 -2.06874278 0.51087697 936.00 -3.00583139e-01 -3.78128168e-01 4.83043616e-01 -2.24243445 0.63546585 936.25 -2.92196820e-01 -2.98805526e-01 4.17927893e-01 -2.34501276 0.52976767 936.50 -2.67030872e-01 -2.63921845e-01 3.75446703e-01 -2.36204998 0.51218918 936.75 -2.95763061e-01 -2.39287329e-01 3.80439501e-01 -2.46135727 0.55883232 937.00 -2.96684325e-01 -2.12105699e-01 3.64705931e-01 -2.52092298 0.57122108 937.25 -2.77212349e-01 -1.83735807e-01 3.32574102e-01 -2.55627310 0.52135825 937.50 -2.59533265e-01 -1.82207807e-01 3.17107554e-01 -2.52948578 0.49974876 937.75 -2.90055120e-01 -1.93102966e-01 3.48454772e-01 -2.55422787 0.55513698 938.00 -2.93065699e-01 -1.39800317e-01 3.24702375e-01 -2.69649159 0.49681325 938.25 -2.43386065e-01 -1.31493828e-01 2.76635868e-01 -2.64625152 0.46695070 938.50 -2.49057922e-01 -1.23753007e-01 2.78109071e-01 -2.68044059 0.46750897 938.75 -2.51650822e-01 -1.01261322e-01 2.71260007e-01 -2.75902918 0.43015736 939.00 -2.62204217e-01 -8.66713925e-02 2.76157530e-01 -2.82234991 0.50888377 939.25 -1.77813560e-01 -9.40480268e-02 2.01153408e-01 -2.65508254 0.30784261 939.50 -1.53254570e-01 -6.69289510e-02 1.67231719e-01 -2.72983920 0.18050276 939.75 -1.59239397e-01 -3.29831426e-04 1.59239738e-01 -3.13952136 0.21583314 940.00 -1.54898059e-01 1.27240551e-02 1.55419787e-01 3.05963197 0.24340711 940.25 -1.03591857e-01 -2.50450292e-03 1.03622127e-01 -3.11742072 0.16109315 940.50 -9.59139045e-02 -9.11590109e-03 9.63461298e-02 -3.04683475 0.15692628 940.75 -6.84881864e-02 -9.46732612e-03 6.91394384e-02 -3.00423018 0.05340087 941.00 -7.30011070e-02 -2.00191471e-02 7.56962871e-02 -2.87394176 0.05810192 941.25 -1.10711337e-01 -9.57450394e-02 1.46369781e-01 -2.42855924 0.19439468 941.50 -1.01619841e-01 -1.34936083e-01 1.68921102e-01 -2.21627601 0.28558098 941.75 -1.16513114e-01 -1.56285543e-01 1.94937110e-01 -2.21142043 0.35964893 942.00 -1.43070421e-01 -1.59787610e-01 2.14478963e-01 -2.30105235 0.49145338 942.25 -1.44775557e-01 -1.73786586e-01 2.26189609e-01 -2.26537634 0.56514778 942.50 -1.63804979e-01 -1.40402133e-01 2.15742509e-01 -2.43297390 0.54618809 942.75 -1.98915163e-01 -9.73425469e-02 2.21456121e-01 -2.68648745 0.57006491 943.00 -2.16570363e-01 -8.07710335e-02 2.31142126e-01 -2.78461593 0.62172905 943.25 -2.11282831e-01 -7.82980825e-02 2.25324265e-01 -2.78669896 0.68999307 943.50 -2.06440905e-01 -7.38777021e-02 2.19261857e-01 -2.79792958 0.68290156 943.75 -1.88759057e-01 -4.48149823e-02 1.94006093e-01 -2.90848955 0.66786269 944.00 -1.70061131e-01 -2.31551628e-02 1.71630270e-01 -3.00626695 0.61661991 944.25 -1.72147028e-01 -1.23441593e-02 1.72589042e-01 -3.07000811 0.70058174 944.50 -1.57496894e-01 -1.79760465e-02 1.58519431e-01 -3.02794855 0.65339163 944.75 -1.46781504e-01 -2.68573590e-02 1.49218389e-01 -2.96061949 0.65015986 945.00 -1.43921103e-01 -3.12289802e-02 1.47270272e-01 -2.92791825 0.62995782 945.25 -1.66525392e-01 -5.13001169e-02 1.74248122e-01 -2.84275619 0.78960361 945.50 -1.83946324e-01 -5.37069558e-02 1.91626426e-01 -2.85751828 0.78816080 945.75 -1.97430639e-01 -3.94374549e-02 2.01330996e-01 -2.94443415 0.72442577 946.00 -1.90607909e-01 -3.95280220e-02 1.94663400e-01 -2.93711235 0.76529956 946.25 -2.09652202e-01 -4.60866021e-02 2.14657916e-01 -2.92521016 0.81957125 946.50 -2.32914757e-01 -4.44082745e-02 2.37110478e-01 -2.95319069 0.87044217 946.75 -2.46605172e-01 -3.28015935e-02 2.48777120e-01 -3.00935627 0.88140373 947.00 -2.58003591e-01 -1.69230006e-02 2.58558003e-01 -3.07609437 0.82221042 947.25 -2.75660681e-01 2.11542075e-02 2.76471176e-01 3.06500274 0.83598931 947.50 -2.54116106e-01 3.69702522e-02 2.56791345e-01 2.99712059 0.79535812 947.75 -2.53825378e-01 7.26546396e-02 2.64018975e-01 2.86280825 0.80736517 948.00 -2.71334948e-01 1.02837038e-01 2.90169107e-01 2.77931623 0.77759641 948.25 -2.43456728e-01 1.54219703e-01 2.88192462e-01 2.57693402 0.75163727 948.50 -2.13996192e-01 1.70162655e-01 2.73403913e-01 2.46980578 0.76395267 948.75 -1.89428988e-01 1.74113749e-01 2.57291545e-01 2.39829735 0.73896995 949.00 -1.59723282e-01 1.45644390e-01 2.16156922e-01 2.40226659 0.58863109 949.25 -1.54936860e-01 1.25757539e-01 1.99550468e-01 2.45977649 0.43427243 949.50 -1.58103966e-01 1.33173967e-01 2.06717608e-01 2.44157477 0.23911542 949.75 -1.17119095e-01 1.43321129e-01 1.85088704e-01 2.25592517 0.22607082 950.00 -1.11389715e-01 1.41609524e-01 1.80169160e-01 2.23731149 0.38917362 950.25 -9.91819672e-02 1.27169422e-01 1.61273446e-01 2.23317284 0.36082521 950.50 -1.05534634e-01 7.76680061e-02 1.31033882e-01 2.50714563 0.26584109 950.75 -1.13653142e-01 5.89982809e-02 1.28054027e-01 2.66277558 0.26963204 951.00 -8.95858093e-02 8.98132493e-02 1.26854393e-01 2.35492670 0.29659855 951.25 -9.46170615e-02 1.05618797e-01 1.41801688e-01 2.30130580 0.36156377 951.50 -1.21058463e-01 1.20679869e-01 1.70935023e-01 2.35776062 0.48007129 951.75 -1.36244862e-01 1.11292944e-01 1.75922659e-01 2.45665559 0.47590240 952.00 -1.51507306e-01 1.34474430e-01 2.02577976e-01 2.41568353 0.53742780 952.25 -1.19253555e-01 1.56153506e-01 1.96482386e-01 2.22300438 0.57101011 952.50 -9.19886337e-02 1.49849115e-01 1.75831357e-01 2.12135565 0.51479876 952.75 -9.06035057e-02 1.48146062e-01 1.73655553e-01 2.11968871 0.47347026 953.00 -1.10212725e-01 1.79628260e-01 2.10744292e-01 2.12112684 0.59763967 953.25 -1.10901069e-01 2.14138623e-01 2.41152228e-01 2.04865630 0.65594471 953.50 -1.03710999e-01 2.58987345e-01 2.78981032e-01 1.95168897 0.65568076 953.75 -8.35502272e-02 2.79506034e-01 2.91726350e-01 1.86126293 0.65676741 954.00 -8.09384367e-03 3.15187914e-01 3.15291819e-01 1.59647011 0.65986288 954.25 1.66778429e-02 3.21737974e-01 3.22169947e-01 1.51900596 0.68181091 954.50 3.78212673e-02 2.99205498e-01 3.01586436e-01 1.44505754 0.70933532 954.75 7.26473631e-02 2.80442074e-01 2.89698803e-01 1.31732218 0.67081252 955.00 1.46876377e-01 2.64625738e-01 3.02654012e-01 1.06409618 0.73180454 955.25 1.39265691e-01 2.50345686e-01 2.86474947e-01 1.06313406 0.72868248 955.50 1.93247360e-01 2.40301981e-01 3.08365991e-01 0.89350848 0.69201140 955.75 2.16346578e-01 2.06916481e-01 2.99366451e-01 0.76312233 0.65742299 956.00 2.19209307e-01 1.59567158e-01 2.71135387e-01 0.62922046 0.71578952 956.25 2.08454788e-01 1.18777546e-01 2.39919787e-01 0.51791759 0.59045260 956.50 2.29126040e-01 7.11295042e-02 2.39912794e-01 0.30100552 0.52234080 956.75 2.23047564e-01 4.53541549e-02 2.27611984e-01 0.20060358 0.52393347 957.00 2.37271633e-01 6.58016960e-03 2.37362858e-01 0.02772554 0.67579195 957.25 2.07501398e-01 -8.94291123e-04 2.07503325e-01 -0.00430978 0.66046454 957.50 1.96144888e-01 1.82340928e-03 1.96153363e-01 0.00929597 0.59654106 957.75 1.82301169e-01 -3.04295255e-02 1.84823355e-01 -0.16539416 0.62426626 958.00 1.96442824e-01 -2.50265281e-02 1.98030579e-01 -0.12671593 0.68667949 958.25 1.94864168e-01 -4.53884230e-02 2.00080366e-01 -0.22884312 0.63410255 958.50 2.06112695e-01 -6.77967496e-02 2.16976594e-01 -0.31778277 0.68027210 958.75 1.82104490e-01 -8.55740487e-02 2.01208755e-01 -0.43929314 0.64197087 959.00 1.30028640e-01 -1.13906179e-01 1.72864296e-01 -0.71940083 0.47974532 959.25 7.70234659e-02 -1.57624750e-01 1.75437100e-01 -1.11626920 0.51850710 959.50 4.26179557e-02 -1.52610402e-01 1.58449439e-01 -1.29847411 0.60586476 959.75 1.55321883e-02 -1.15565971e-01 1.16605071e-01 -1.43719587 0.51455236 960.00 8.81171156e-03 -9.96525107e-02 1.00041337e-01 -1.48260133 0.54115270 960.25 3.64511657e-03 -8.39151788e-02 8.39943100e-02 -1.52738551 0.47546279 960.50 -1.17853424e-02 -7.79191839e-02 7.88054155e-02 -1.72090937 0.46795968 960.75 -2.17918860e-02 -7.18877775e-02 7.51181660e-02 -1.86512913 0.51394012 961.00 -1.31556488e-02 -5.34831948e-02 5.50774293e-02 -1.81198530 0.36625677 961.25 3.00527026e-04 -5.45950987e-02 5.45959259e-02 -1.56529173 0.26792915 961.50 -5.99704290e-03 -5.86641832e-02 5.89699153e-02 -1.67266909 0.28872811 961.75 -2.44234190e-02 -5.41793244e-02 5.94298123e-02 -1.99430582 0.26292897 962.00 -2.35091385e-02 -3.04915371e-02 3.85021224e-02 -2.22760589 0.10395810 962.25 -7.28639958e-03 -1.21015773e-02 1.41258554e-02 -2.11276093 0.01490783 962.50 -6.69107411e-03 -1.66796413e-02 1.79716695e-02 -1.95229555 0.02100891 962.75 1.39695409e-02 -2.88582824e-02 3.20616365e-02 -1.11997059 0.06130606 963.00 2.16318693e-02 -3.97287913e-02 4.52362093e-02 -1.07219445 0.10652824 963.25 6.20443746e-03 -2.82191836e-02 2.88932063e-02 -1.35437389 0.05801429 963.50 6.63022249e-03 -2.51664334e-02 2.60251651e-02 -1.31319478 0.05370335 963.75 1.08556696e-02 -1.74033364e-02 2.05115012e-02 -1.01308239 0.02661386 964.00 1.41844942e-02 -1.94095966e-02 2.40402229e-02 -0.93969819 0.04100110 964.25 3.00740271e-02 -4.31447707e-02 5.25919989e-02 -0.96205352 0.22546795 964.50 2.60391953e-02 -4.35352630e-02 5.07282842e-02 -1.03176229 0.21347695 964.75 1.34867003e-02 -4.55774266e-02 4.75309678e-02 -1.28309838 0.15480357 965.00 -9.77372732e-03 -4.61505519e-02 4.71741368e-02 -1.77949197 0.16905336 965.25 -1.87596035e-02 -2.35716111e-02 3.01254639e-02 -2.24300521 0.07436248 965.50 -1.47251643e-02 -6.24428073e-03 1.59944211e-02 -2.74052263 0.01901957 965.75 7.07073824e-03 8.49384761e-03 1.10517323e-02 0.87657717 0.00614677 966.00 -1.77389548e-02 9.14045581e-03 1.99554115e-02 2.66579915 0.01404830 966.25 -2.69471308e-02 4.84347463e-02 5.54262800e-02 2.07850895 0.07594561 966.50 1.18767646e-02 2.86370904e-02 3.10022658e-02 1.17765342 0.03185136 966.75 2.76623772e-02 -4.68794332e-03 2.80567982e-02 -0.16787501 0.03817911 967.00 1.85051015e-02 -2.26222290e-02 2.92267690e-02 -0.88517261 0.04117026 967.25 1.56743090e-02 -1.79671330e-02 2.38432764e-02 -0.85344767 0.02505297 967.50 -5.10266263e-03 -2.43589766e-02 2.48876859e-02 -1.77728824 0.02912037 967.75 -1.01707033e-02 -2.09043870e-02 2.32472923e-02 -2.02361354 0.02296206 968.00 -9.02259849e-03 -1.30007768e-02 1.58249007e-02 -2.17748717 0.01600248 968.25 -2.81976882e-02 -4.89720962e-03 2.86197883e-02 -2.96963373 0.06499016 968.50 -4.68885461e-02 2.35504931e-02 5.24705773e-02 2.67613439 0.20306761 968.75 -5.17006820e-02 1.58868523e-02 5.40865288e-02 2.84346570 0.21115706 969.00 -3.37376232e-02 1.42855433e-02 3.66374667e-02 2.74105202 0.11274340 969.25 -3.33745868e-02 2.48118072e-02 4.15871232e-02 2.50230696 0.14756421 969.50 -3.63096188e-02 2.55163888e-02 4.43787620e-02 2.52902704 0.19642251 969.75 -3.99347681e-02 2.30572047e-02 4.61131260e-02 2.61797781 0.21363735 970.00 -5.08451835e-02 5.04150085e-02 7.16024145e-02 2.36044268 0.45638377 970.25 -5.23888913e-02 6.50147142e-02 8.34955627e-02 2.24906419 0.47781660 970.50 -6.50601704e-02 8.19829334e-02 1.04661488e-01 2.24161151 0.51720327 970.75 -5.39501485e-02 8.89089952e-02 1.03997250e-01 2.11620223 0.47684333 971.00 -4.38065534e-02 1.12332786e-01 1.20572256e-01 1.94262742 0.43553828 971.25 -1.70483831e-02 1.08671829e-01 1.10000971e-01 1.72640752 0.31245072 971.50 -1.60865574e-03 8.74698440e-02 8.74846351e-02 1.58918523 0.23090612 971.75 6.91258854e-03 8.95763211e-02 8.98426468e-02 1.49377915 0.22769377 972.00 7.54620585e-02 7.91893446e-02 1.09386812e-01 0.80949471 0.27385647 972.25 9.52268683e-02 4.87105278e-02 1.06962012e-01 0.47282175 0.24148675 972.50 1.41629760e-01 5.22280807e-02 1.50952844e-01 0.35329309 0.37130174 972.75 1.51476713e-01 4.24098721e-02 1.57301595e-01 0.27298662 0.39397474 973.00 1.11399326e-01 5.91602519e-03 1.11556306e-01 0.05305663 0.28062326 973.25 1.14548003e-01 3.70554838e-03 1.14607923e-01 0.03233803 0.37831564 973.50 1.10333665e-01 -2.52897437e-03 1.10362645e-01 -0.02291714 0.41272775 973.75 1.13460047e-01 -4.41585504e-03 1.13545947e-01 -0.03890028 0.34161947 974.00 1.65147012e-01 -3.49174916e-02 1.68798006e-01 -0.20836406 0.48724750 974.25 1.30880472e-01 -6.47838365e-02 1.46036446e-01 -0.45962736 0.50542250 974.50 9.02203176e-02 -5.26241553e-02 1.04446194e-01 -0.52803836 0.37762952 974.75 9.62683744e-02 -5.04756160e-02 1.08698610e-01 -0.48291526 0.43019943 975.00 9.68802319e-02 -5.42190378e-02 1.11020194e-01 -0.51022196 0.51452989 975.25 8.80720137e-02 -6.80633560e-02 1.11307233e-01 -0.65794341 0.48841757 975.50 9.14738206e-02 -9.97298607e-02 1.35327399e-01 -0.82855065 0.56120555 975.75 9.81323104e-02 -9.35920064e-02 1.35607574e-01 -0.76172117 0.55709176 976.00 5.99636411e-02 -7.83586574e-02 9.86697392e-02 -0.91760903 0.33515748 976.25 4.90106223e-02 -9.91391864e-02 1.10592131e-01 -1.11166948 0.46718751 976.50 3.64810930e-02 -1.18349978e-01 1.23845014e-01 -1.27179024 0.42749383 976.75 2.57461197e-02 -1.02520146e-01 1.05703562e-01 -1.32475226 0.38306821 977.00 2.04121792e-02 -9.07396796e-02 9.30072390e-02 -1.34952645 0.32732603 977.25 2.34238947e-02 -1.16686620e-01 1.19014479e-01 -1.37268750 0.44147722 977.50 2.29755144e-02 -1.14214316e-01 1.16502293e-01 -1.37228426 0.51117600 977.75 2.38896757e-02 -1.18853691e-01 1.21230839e-01 -1.37243874 0.54298027 978.00 1.91118816e-02 -1.23682470e-01 1.25150379e-01 -1.41748512 0.59702532 978.25 9.64039354e-03 -1.28588145e-01 1.28949014e-01 -1.49596523 0.54560550 978.50 1.45983106e-02 -1.52789797e-01 1.53485611e-01 -1.47554042 0.61710300 978.75 3.38534250e-02 -1.44888220e-01 1.48790627e-01 -1.34126219 0.60136026 979.00 5.49259124e-02 -1.49609426e-01 1.59373261e-01 -1.21894433 0.64151466 979.25 7.78851928e-02 -1.72072574e-01 1.88878464e-01 -1.14575752 0.65140411 979.50 6.79671415e-02 -1.90557555e-01 2.02315877e-01 -1.22818726 0.61213256 979.75 9.73133344e-03 -2.09098404e-01 2.09324727e-01 -1.52429039 0.59511566 980.00 -2.36802084e-02 -2.27313865e-01 2.28543968e-01 -1.67459598 0.64919280 980.25 -1.02987916e-02 -2.72346742e-01 2.72541397e-01 -1.60859332 0.70858033 980.50 4.75706335e-03 -3.00313571e-01 3.00351245e-01 -1.55495733 0.79558960 980.75 3.56041389e-03 -2.99448009e-01 2.99469175e-01 -1.55890696 0.83268258 981.00 -2.97689761e-03 -2.91594766e-01 2.91609961e-01 -1.58100499 0.84711584 981.25 -3.94830658e-03 -3.26495979e-01 3.26519852e-01 -1.58288871 0.81216047 981.50 1.66334288e-02 -3.49899973e-01 3.50295107e-01 -1.52329442 0.84547472 981.75 3.84480769e-02 -3.39377291e-01 3.41548240e-01 -1.45798724 0.72395594 982.00 3.00510783e-02 -3.35293608e-01 3.36637596e-01 -1.48140900 0.61823164 982.25 -6.97115007e-03 -3.71256062e-01 3.71321506e-01 -1.58957132 0.59561259 982.50 2.32416955e-02 -3.82816707e-01 3.83521587e-01 -1.51015842 0.57822487 982.75 -3.14549368e-02 -3.32733463e-01 3.34216951e-01 -1.66505115 0.46454616 983.00 -7.79923022e-02 -3.25794081e-01 3.34999377e-01 -1.80576578 0.46053751 983.25 -1.09301502e-01 -2.92885718e-01 3.12616158e-01 -1.92797765 0.25369705 983.50 -1.26832811e-01 -3.19033006e-01 3.43319998e-01 -1.94919221 0.22403570 983.75 -1.57771575e-01 -1.71047795e-01 2.32699845e-01 -2.31584099 0.12661848 984.00 -1.90311640e-01 -1.25072048e-01 2.27731283e-01 -2.56017536 0.13980685 984.25 -8.43618640e-02 1.59046075e-02 8.58480090e-02 2.95525141 0.01368471 984.50 -5.78016825e-03 5.08451696e-02 5.11726647e-02 1.68399212 0.00302675 984.75 -5.28568606e-02 9.09499392e-02 1.05193817e-01 2.09725092 0.01772448 985.00 -1.66871318e-01 1.23992465e-01 2.07894608e-01 2.50255930 0.07489861 985.25 -1.73048194e-01 2.34655485e-01 2.91562814e-01 2.20622109 0.15152529 985.50 -1.67840117e-01 2.86729911e-01 3.32241398e-01 2.10038130 0.15164071 985.75 -3.54441870e-02 2.65525149e-01 2.67880375e-01 1.70349895 0.11105989 986.00 5.29477014e-02 2.64737107e-01 2.69979990e-01 1.37339975 0.12241233 986.25 -2.77493300e-02 2.56597300e-01 2.58093393e-01 1.67852118 0.14767070 986.50 -5.53880361e-02 2.17008625e-01 2.23965573e-01 1.82069525 0.15189752 986.75 -8.28857852e-03 1.60789396e-01 1.61002889e-01 1.62230002 0.07550017 987.00 -3.11674867e-02 1.76354517e-01 1.79087487e-01 1.74572203 0.10320694 987.25 -9.34147911e-02 2.29426388e-01 2.47715140e-01 1.95746561 0.20250097 987.50 -3.91884675e-02 1.81920309e-01 1.86093350e-01 1.78296966 0.12826791 987.75 1.69968890e-02 8.96557922e-02 9.12527003e-02 1.38344038 0.03934105 988.00 4.03538732e-02 5.05656032e-02 6.46940129e-02 0.89724562 0.02125107 988.25 2.28932127e-02 -1.00256220e-02 2.49922445e-02 -0.41277121 0.00397272 988.50 2.86217789e-02 -4.37300257e-02 5.22639587e-02 -0.99125653 0.01527738 988.75 8.31898734e-02 3.92911971e-02 9.20019195e-02 0.44124917 0.04701818 989.00 6.66149097e-02 3.60255616e-02 7.57323398e-02 0.49575498 0.04825267 989.25 6.67362356e-02 1.94945538e-02 6.95252671e-02 0.28420584 0.05524318 989.50 1.01935104e-01 5.44392750e-02 1.15561239e-01 0.49052148 0.14394661 989.75 8.23826038e-02 7.60325968e-02 1.12106419e-01 0.74533503 0.14156987 990.00 6.48139723e-02 5.41263125e-02 8.44423395e-02 0.69578149 0.07713154 990.25 9.17930606e-02 5.69827319e-02 1.08041648e-01 0.55555451 0.12659891 990.50 7.20926866e-02 3.83456581e-02 8.16562610e-02 0.48883597 0.12555993 990.75 5.58746659e-02 6.39514657e-02 8.49221306e-02 0.85270069 0.11537701 991.00 6.40116405e-02 1.15805926e-01 1.32319698e-01 1.06584481 0.20371575 991.25 8.61631601e-02 1.17775276e-01 1.45928427e-01 0.93918240 0.24728094 991.50 1.37406044e-01 1.32562481e-01 1.90927296e-01 0.76745887 0.37843435 991.75 1.20847087e-01 1.27531587e-01 1.75693836e-01 0.81230421 0.40940091 992.00 1.39857028e-01 1.26107402e-01 1.88316397e-01 0.73374691 0.60038326 992.25 1.51063121e-01 1.03552340e-01 1.83147901e-01 0.60092155 0.61362511 992.50 1.70970894e-01 1.20396393e-01 2.09108436e-01 0.61353407 0.71377613 992.75 1.66527272e-01 1.41468570e-01 2.18505580e-01 0.70421646 0.72694420 993.00 1.59084646e-01 1.28452980e-01 2.04470273e-01 0.67926746 0.69960145 993.25 1.63913280e-01 1.10871182e-01 1.97888813e-01 0.59471183 0.71605524 993.50 1.63422685e-01 9.19836890e-02 1.87531258e-01 0.51266102 0.80972123 993.75 1.58312249e-01 7.88605806e-02 1.76866501e-01 0.46215302 0.78497530 994.00 1.45910891e-01 6.90415559e-02 1.61420955e-01 0.44195920 0.80963942 994.25 1.43366916e-01 6.18212935e-02 1.56127976e-01 0.40711906 0.82336442 994.50 1.45751961e-01 4.54276310e-02 1.52667298e-01 0.30213552 0.75484502 994.75 1.40859507e-01 4.87711684e-02 1.49063837e-01 0.33332106 0.73986356 995.00 1.29469717e-01 5.22512454e-02 1.39615903e-01 0.38358782 0.67456592 995.25 1.31199399e-01 4.37445691e-02 1.38299926e-01 0.32182900 0.62447458 995.50 1.22931755e-01 4.96876548e-02 1.32593663e-01 0.38411230 0.69474943 995.75 1.21521867e-01 5.54178597e-02 1.33561609e-01 0.42785880 0.70870170 996.00 1.30920892e-01 4.20723108e-02 1.37514942e-01 0.31093317 0.57025742 996.25 1.32959568e-01 3.04316554e-02 1.36397699e-01 0.22500347 0.52163890 996.50 1.37916522e-01 2.50259497e-02 1.40168703e-01 0.17950407 0.62677352 996.75 1.35258123e-01 2.85364592e-03 1.35288222e-01 0.02109465 0.60665529 997.00 1.20007363e-01 -1.94843158e-02 1.21578804e-01 -0.16095486 0.44610667 997.25 1.13397550e-01 -2.67727445e-02 1.16515168e-01 -0.23185065 0.37943704 997.50 1.00115858e-01 -3.71493480e-02 1.06786044e-01 -0.35531510 0.45494544 997.75 9.14895113e-02 -4.19200784e-02 1.00636095e-01 -0.42964833 0.41305510 998.00 7.62103481e-02 -4.87858891e-02 9.04880110e-02 -0.56941806 0.30998415 998.25 5.56290229e-02 -2.75168409e-02 6.20625872e-02 -0.45935766 0.19220642 998.50 4.02552808e-02 -1.26115209e-02 4.21845717e-02 -0.30360316 0.11383293 998.75 3.77377458e-02 4.50900417e-03 3.80061649e-02 0.11891884 0.09958103 999.00 5.70815480e-02 1.06964039e-02 5.80750909e-02 0.18523987 0.20874705 999.25 7.73606737e-02 1.02652524e-02 7.80387675e-02 0.13192274 0.29432538 999.50 9.73946217e-02 2.56062273e-02 1.00704475e-01 0.25709385 0.44577767 999.75 1.00964416e-01 1.05397458e-02 1.01513051e-01 0.10401396 0.48929609 1000.00 1.13947567e-01 0.00000000e+00 1.13947567e-01 0.00000000 0.53682032