========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0053 Injection acquisition : SIG0054 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -3.08262952e-02 0.00000000e+00 3.08262952e-02 3.14159265 0.04430072 0.25 -2.98995438e-02 1.44959471e-02 3.32282290e-02 2.69016126 0.05071355 0.50 -1.34845069e-02 1.46860407e-03 1.35642443e-02 3.03310975 0.00796715 0.75 -2.19078614e-02 2.71153135e-03 2.20750265e-02 3.01844913 0.01793612 1.00 -1.84662388e-02 1.68772727e-02 2.50168804e-02 2.40112203 0.01539821 1.25 -1.77736450e-02 6.02483152e-03 1.87670203e-02 2.81477271 0.00992030 1.50 2.81485184e-03 3.13511229e-03 4.21335020e-03 0.83917188 0.00033898 1.75 -1.96517515e-02 1.76166512e-03 1.97305550e-02 3.05218745 0.00947397 2.00 -2.94679492e-02 -1.25638847e-02 3.20345318e-02 -2.73857265 0.02074126 2.25 -2.54397365e-02 -5.19535033e-04 2.54450410e-02 -3.12117331 0.01521450 2.50 -3.55590045e-02 3.39277575e-03 3.57204945e-02 3.04646805 0.03009036 2.75 -2.16949320e-02 1.15093578e-02 2.45588149e-02 2.65383674 0.01579021 3.00 -1.39563204e-02 2.22852080e-02 2.62946643e-02 2.13030075 0.01556686 3.25 -1.49354277e-02 6.72580757e-03 1.63799721e-02 2.71846787 0.00829544 3.50 -1.31868797e-02 2.46283087e-03 1.34148922e-02 2.95695606 0.00550870 3.75 -1.66114715e-02 4.00962868e-04 1.66163100e-02 3.11745963 0.00956328 4.00 -1.86898086e-02 6.38885576e-04 1.87007251e-02 3.10742233 0.01271057 4.25 -1.49082529e-02 1.19496748e-03 1.49560674e-02 3.06160889 0.00759520 4.50 -1.32753817e-02 5.61276514e-03 1.44131499e-02 2.74159113 0.00647685 4.75 -2.22387148e-02 -5.10354276e-03 2.28168049e-02 -2.91600955 0.01415031 5.00 -1.76897279e-02 -9.90243394e-03 2.02727569e-02 -2.63126847 0.01020180 5.25 -2.20440102e-02 8.74188060e-03 2.37141068e-02 2.76405108 0.01078070 5.50 -2.53254623e-02 7.07626645e-03 2.62954861e-02 2.86912825 0.01353958 5.75 -3.46241353e-02 1.23103063e-02 3.67474405e-02 2.79998992 0.02191498 6.00 -2.80834149e-02 1.50690156e-02 3.18708868e-02 2.64911059 0.01659729 6.25 -1.64907294e-03 1.04110676e-02 1.05408620e-02 1.72788737 0.00236502 6.50 -6.98679478e-03 8.43358790e-03 1.09517444e-02 2.26264492 0.00248179 6.75 -5.41564049e-03 -9.21696036e-03 1.06902535e-02 -2.10202849 0.00241642 7.00 -5.59029477e-03 -5.48723357e-03 7.83333440e-03 -2.36549785 0.00141294 7.25 -1.97842184e-02 2.20977467e-03 1.99072450e-02 3.03035988 0.00891190 7.50 -2.16816280e-02 3.62321240e-03 2.19822806e-02 2.97601286 0.01087659 7.75 -1.87301884e-02 3.79613554e-04 1.87340349e-02 3.12132796 0.00813713 8.00 -1.48837831e-02 3.14768946e-03 1.52129862e-02 2.93317908 0.00507330 8.25 -2.71641925e-02 1.13420559e-02 2.94369765e-02 2.74606016 0.01697733 8.50 -2.93483352e-02 5.59922488e-03 2.98776857e-02 2.95307308 0.01858391 8.75 -1.60823398e-02 3.23707980e-03 1.64048877e-02 2.94296505 0.00487011 9.00 -1.85414380e-02 1.15811263e-02 2.18610935e-02 2.58327544 0.00835897 9.25 -2.66910804e-02 1.35105338e-02 2.99156865e-02 2.67301200 0.01412602 9.50 -9.44375492e-03 6.50197346e-03 1.14656080e-02 2.53863030 0.00199004 9.75 5.84507202e-03 1.20337908e-02 1.33782281e-02 1.11863655 0.00229564 10.00 -1.12096209e-02 2.04565320e-03 1.13947487e-02 2.96108809 0.00181215 10.25 -1.53508006e-02 -4.38658488e-03 1.59652500e-02 -2.86325434 0.00269586 10.50 -1.47119128e-02 7.49141405e-03 1.65094416e-02 2.67060633 0.00370288 10.75 -1.32825972e-02 1.87490853e-02 2.29772842e-02 2.18716412 0.00704532 11.00 -1.98635521e-02 1.13239019e-02 2.28646333e-02 2.62346040 0.00766735 11.25 -2.16924507e-02 5.28579250e-03 2.23271588e-02 2.90258076 0.00769807 11.50 -1.05907796e-02 2.31483476e-03 1.08408059e-02 2.92640601 0.00185314 11.75 -1.33616521e-02 6.93881646e-03 1.50559264e-02 2.66261801 0.00349002 12.00 -2.48905064e-02 6.56671833e-03 2.57421658e-02 2.88364588 0.00943327 12.25 -2.07126265e-02 8.72225007e-03 2.24742195e-02 2.74302329 0.00687521 12.50 -1.22967189e-02 1.02360450e-02 1.59995598e-02 2.44739314 0.00318697 12.75 -1.47625771e-02 1.53173174e-02 2.12733142e-02 2.33775435 0.00475697 13.00 -1.52962450e-02 5.33128904e-04 1.53055329e-02 3.10675318 0.00264696 13.25 -2.05533017e-03 -3.04159655e-03 3.67092518e-03 -2.16505458 0.00013674 13.50 -1.08264778e-02 2.19020599e-02 2.44317999e-02 2.02988417 0.00551631 13.75 -3.05336282e-02 2.69598210e-02 4.07324735e-02 2.41827486 0.01323933 14.00 -8.20383485e-03 6.23184739e-04 8.22747017e-03 3.06577565 0.00057675 14.25 -3.66295624e-03 -2.31061947e-03 4.33084412e-03 -2.57882821 0.00015392 14.50 -1.48789811e-02 5.01500494e-03 1.57014125e-02 2.81649816 0.00214030 14.75 -2.61690358e-02 1.18166976e-02 2.87132857e-02 2.71744829 0.00678575 15.00 -1.84553212e-02 -2.91952757e-02 3.45392965e-02 -2.13450914 0.01003112 15.25 -9.29050081e-03 -8.85231921e-03 1.28326521e-02 -2.38034159 0.00136180 15.50 -3.26857826e-02 5.48088374e-04 3.26903776e-02 3.12482582 0.00851342 15.75 -3.40913031e-02 -3.09210061e-03 3.42312435e-02 -3.05113958 0.00950748 16.00 -1.25482880e-02 -8.14317371e-03 1.49589709e-02 -2.56595804 0.00210773 16.25 -1.77942782e-02 -1.74970173e-02 2.49555996e-02 -2.36461736 0.00585618 16.50 -2.72274862e-02 -1.95269124e-02 3.35057653e-02 -2.51943164 0.00907554 16.75 -2.39071491e-02 -2.38180405e-02 3.37468640e-02 -2.35806161 0.00897301 17.00 1.18642999e-02 2.49874704e-02 2.76610790e-02 1.12750305 0.00518923 17.25 -6.55334879e-03 3.09020360e-02 3.15892736e-02 1.77976884 0.00700494 17.50 -4.45575693e-02 -2.74509984e-03 4.46420492e-02 -3.08006249 0.01155774 17.75 -2.12004543e-02 -1.13945136e-03 2.12310530e-02 -3.08789776 0.00277672 18.00 -2.49343658e-02 1.98153556e-02 3.18491902e-02 2.47009141 0.00583008 18.25 -2.46764729e-02 7.60595750e-03 2.58220623e-02 2.84260526 0.00407203 18.50 -7.25712603e-03 -2.57175735e-02 2.67218911e-02 -1.84583048 0.00509751 18.75 -4.94883003e-03 -1.15131664e-02 1.25317165e-02 -1.97676012 0.00116040 19.00 -1.78638455e-02 7.27389296e-03 1.92879884e-02 2.75490755 0.00260503 19.25 -2.47174717e-02 -5.74257441e-03 2.53757870e-02 -2.91331383 0.00447551 19.50 -2.19795135e-02 -2.59689861e-02 3.40218643e-02 -2.27318241 0.00786593 19.75 -4.35139895e-02 5.04486465e-03 4.38054556e-02 3.02617134 0.01240455 20.00 -6.28015126e-02 3.31918575e-02 7.10332977e-02 2.65539019 0.02986246 20.25 -4.22080195e-02 2.01177002e-02 4.67572322e-02 2.69681345 0.01316644 20.50 -7.24503067e-03 2.59029627e-02 2.68970992e-02 1.84352582 0.00409108 20.75 -1.32569834e-02 1.91109485e-02 2.32588900e-02 2.17727163 0.00288799 21.00 -1.90847028e-02 -1.69085605e-02 2.54975548e-02 -2.41658069 0.00318224 21.25 -2.92264291e-02 -2.16354375e-02 3.63631175e-02 -2.50434813 0.00681807 21.50 -1.95096341e-02 -1.48132208e-02 2.44960677e-02 -2.49218051 0.00264558 21.75 -3.47424271e-02 -1.33656433e-02 3.72246781e-02 -2.77433930 0.00701176 22.00 -5.90139224e-02 -3.82794795e-02 7.03417486e-02 -2.56616587 0.02281500 22.25 -3.78358693e-02 -1.30328168e-02 4.00175876e-02 -2.80986474 0.00701154 22.50 -1.88780803e-02 -8.87454272e-03 2.08599958e-02 -2.70215172 0.00175300 22.75 -3.35412311e-02 -1.13411157e-03 3.35603992e-02 -3.10779307 0.00508621 23.00 -2.29275707e-02 -1.82049672e-02 2.92761734e-02 -2.47050824 0.00412396 23.25 -1.95169342e-02 1.02049836e-02 2.20239054e-02 2.65981028 0.00252891 23.50 -5.37970512e-02 2.07305786e-02 5.76530971e-02 2.77378089 0.01570067 23.75 -5.98669690e-02 -1.39154535e-02 6.14629468e-02 -2.91320849 0.01896272 24.00 -4.62306627e-02 -4.55229385e-02 6.48815236e-02 -2.36390765 0.02170243 24.25 -2.73071993e-02 -6.82989146e-03 2.81483668e-02 -2.89650744 0.00407155 24.50 -4.30545091e-02 -1.16388195e-02 4.45999201e-02 -2.87757556 0.00915021 24.75 -4.63091555e-02 1.86223748e-02 4.99132320e-02 2.75925004 0.01144757 25.00 -4.41221740e-02 1.82183504e-02 4.77354640e-02 2.75000939 0.01002182 25.25 -1.29051547e-02 3.40771169e-02 3.64388929e-02 1.93281074 0.00518015 25.50 -1.46519431e-02 3.27335420e-02 3.58631316e-02 1.99166305 0.00541227 25.75 -8.90456300e-03 -2.45359910e-02 2.61018408e-02 -1.91893309 0.00268523 26.00 -1.57056885e-03 -6.40082433e-03 6.59069333e-03 -1.81141241 0.00017612 26.25 -3.24716882e-02 -1.41936337e-02 3.54382529e-02 -2.72951131 0.00560077 26.50 -3.35622618e-02 -2.25126920e-02 4.04134473e-02 -2.55075191 0.00727636 26.75 -5.77538323e-03 -1.09242446e-02 1.23569483e-02 -2.05712050 0.00056386 27.00 -1.52130335e-05 9.13922265e-03 9.13923532e-03 1.57246091 0.00029639 27.25 -5.34045883e-03 9.56015615e-04 5.42535403e-03 2.96445517 0.00010614 27.50 -8.84113414e-03 -8.53076274e-03 1.22857465e-02 -2.37405888 0.00053380 27.75 9.40878083e-03 -2.06774998e-02 2.27174857e-02 -1.14377141 0.00174443 28.00 -1.33790813e-03 -1.13339417e-02 1.14126347e-02 -1.68829695 0.00044658 28.25 -3.91543362e-02 3.54842586e-03 3.93147983e-02 3.05121291 0.00539296 28.50 -2.80786871e-02 -1.35460003e-02 3.11754197e-02 -2.69209961 0.00329480 28.75 5.24810435e-02 -1.79328201e-02 5.54603098e-02 -0.32926237 0.00946363 29.00 3.72597982e-03 -1.06316811e-02 1.12656810e-02 -1.23371169 0.00037662 29.25 -5.12010494e-02 -3.31166689e-03 5.13080364e-02 -3.07700295 0.00656266 29.50 -3.62300108e-03 4.86856484e-03 6.06869512e-03 2.21055065 0.00009630 29.75 -9.34563752e-03 1.17246899e-01 1.17618775e-01 1.65033719 0.03197617 30.00 -1.88217457e-02 3.25971854e-02 3.76408635e-02 2.09443541 0.00384995 30.25 3.47690316e-02 -4.48377457e-02 5.67389548e-02 -0.91121073 0.00793250 30.50 4.67881046e-03 -2.01077938e-02 2.06449664e-02 -1.34217800 0.00112723 30.75 -2.35897554e-02 -1.22615371e-02 2.65861214e-02 -2.66224475 0.00188603 31.00 -1.14136849e-02 -1.07190811e-02 1.56579342e-02 -2.38756770 0.00068479 31.25 9.11402324e-03 -9.39310483e-02 9.43721741e-02 -1.47407025 0.01590765 31.50 -1.36926732e-02 -2.08836354e-02 2.49722952e-02 -2.15114382 0.00135755 31.75 -3.81906231e-02 1.31733111e-02 4.03987601e-02 2.80943652 0.00412381 32.00 1.68006793e-02 -1.81630369e-02 2.47418418e-02 -0.82434336 0.00132839 32.25 6.56376990e-02 -6.33087684e-02 9.11937919e-02 -0.76733891 0.01315109 32.50 -2.64148965e-02 2.44625881e-03 2.65279275e-02 3.04924699 0.00140008 32.75 -5.06051988e-02 4.65905393e-02 6.87863685e-02 2.39747592 0.00884243 33.00 -2.95452785e-02 -1.03291961e-02 3.12988142e-02 -2.80526920 0.00204867 33.25 1.88443221e-02 -1.23157915e-03 1.88845244e-02 -0.06526264 0.00076675 33.50 -1.10944114e-02 -3.18502726e-02 3.37272268e-02 -1.90598279 0.00231779 33.75 -2.99883682e-02 -8.77378399e-02 9.27212531e-02 -1.90014309 0.01872717 34.00 -3.50726203e-02 -2.26567231e-02 4.17542309e-02 -2.56803834 0.00307078 34.25 2.25130424e-02 -1.77818366e-02 2.86885133e-02 -0.66851874 0.00106161 34.50 1.90386945e-02 -7.06130429e-02 7.31346273e-02 -1.30743863 0.00804248 34.75 5.07203768e-02 -1.29793587e-01 1.39351828e-01 -1.19826582 0.02604436 35.00 3.45159194e-02 1.30727996e-02 3.69086275e-02 0.36205162 0.00198675 35.25 7.90979605e-03 3.55213737e-02 3.63913845e-02 1.35169396 0.00196966 35.50 -4.42385451e-02 -6.31698148e-02 7.71198702e-02 -2.18173129 0.00960433 35.75 -1.98243572e-02 -9.23001264e-02 9.44050765e-02 -1.78236361 0.01430325 36.00 -1.58809254e-01 -4.46697429e-02 1.64972013e-01 -2.86739813 0.03565094 36.25 -3.37583466e-01 5.62214391e-02 3.42233030e-01 2.97656639 0.07662745 36.50 5.21071027e-03 2.65993354e-01 2.66044387e-01 1.55120921 0.02370741 36.75 9.05667458e-02 9.10689819e-02 1.28436346e-01 0.78816323 0.01062686 37.00 9.43229813e-02 -3.82082741e-02 1.01767858e-01 -0.38487728 0.01062243 37.25 5.27913600e-02 -1.30181092e-02 5.43727768e-02 -0.24177182 0.00319286 37.50 6.62380515e-02 5.78972118e-03 6.64906034e-02 0.08718620 0.00646891 37.75 1.00524101e-01 -2.13302848e-02 1.02762230e-01 -0.20908949 0.01449777 38.00 7.97851728e-02 -5.44540067e-02 9.65966492e-02 -0.59888955 0.01439508 38.25 6.41951137e-02 -3.74906199e-02 7.43408313e-02 -0.52857954 0.00782896 38.50 7.78913456e-02 -9.21605334e-03 7.84346693e-02 -0.11777181 0.00717350 38.75 9.65681075e-02 3.35763447e-02 1.02238791e-01 0.33462079 0.01314354 39.00 -3.31377509e-02 6.55412323e-02 7.34422471e-02 2.03891516 0.00667660 39.25 -1.76574768e-03 2.28487331e-02 2.29168599e-02 1.64792293 0.00073376 39.50 1.14585375e-01 -4.79443010e-02 1.24211369e-01 -0.39628035 0.02313104 39.75 4.63102202e-02 -1.29288885e-02 4.80811049e-02 -0.27224818 0.00397737 40.00 -3.18849647e-02 -3.05036179e-02 4.41262017e-02 -2.37833189 0.00268294 40.25 6.22204581e-03 -4.58733623e-02 4.62934037e-02 -1.43598375 0.00328035 40.50 5.55999328e-02 -1.38915131e-02 5.73090452e-02 -0.24483528 0.00462175 40.75 9.33260920e-03 3.30288850e-02 3.43220751e-02 1.29541623 0.00174152 41.00 -1.22599635e-02 5.55723543e-03 1.34606676e-02 2.71601178 0.00027281 41.25 -2.29579574e-02 3.74230927e-02 4.39039369e-02 2.12106166 0.00306385 41.50 2.05087653e-02 4.78850269e-02 5.20920844e-02 1.16614079 0.00393673 41.75 -1.21336199e-02 1.84592621e-02 2.20900224e-02 2.15229938 0.00084814 42.00 -1.22805933e-03 -3.50979328e-02 3.51194109e-02 -1.60577156 0.00211277 42.25 -5.00677399e-03 -2.35089383e-02 2.40361804e-02 -1.78063444 0.00107722 42.50 -1.29101192e-02 -2.37307525e-02 2.70151771e-02 -2.06904052 0.00151922 42.75 -2.77902421e-02 -2.60422012e-02 3.80853488e-02 -2.38865497 0.00262225 43.00 5.38591311e-02 -6.57560392e-02 8.49980159e-02 -0.88453200 0.01127363 43.25 1.63773598e-02 4.54757986e-03 1.69970114e-02 0.27085123 0.00043054 43.50 -2.94734983e-02 -1.42923999e-02 3.27560651e-02 -2.69007861 0.00149435 43.75 -4.48360351e-02 3.14831476e-02 5.47855696e-02 2.52940240 0.00457339 44.00 -1.00968415e-01 3.31550301e-02 1.06272653e-01 2.82431545 0.01809411 44.25 -7.44425387e-03 -2.23299934e-02 2.35381715e-02 -1.89258407 0.00074776 44.50 2.26218074e-02 -3.14587592e-02 3.87478993e-02 -0.94737016 0.00177280 44.75 8.54436291e-02 -3.01698579e-02 9.06136528e-02 -0.33943085 0.01109307 45.00 8.82052544e-02 -8.89609112e-03 8.86527346e-02 -0.10051680 0.00983179 45.25 1.09621025e-01 -2.70390079e-02 1.12906497e-01 -0.24183169 0.01684441 45.50 1.01884708e-01 5.24742690e-02 1.14603851e-01 0.47560374 0.01553895 45.75 9.96100694e-02 -2.67594513e-02 1.03141816e-01 -0.26244570 0.01487763 46.00 8.01521270e-02 1.70011114e-02 8.19353480e-02 0.20901274 0.00884340 46.25 -3.14289744e-02 -2.34498298e-03 3.15163350e-02 -3.06711851 0.00104157 46.50 -7.55518189e-03 -3.96303719e-02 4.03441092e-02 -1.75917707 0.00176864 46.75 2.25499949e-02 -1.49082601e-01 1.50778394e-01 -1.42067590 0.02179206 47.00 7.75903905e-03 -9.50601648e-02 9.53762949e-02 -1.48935447 0.00871955 47.25 -8.03720222e-03 -7.85612516e-02 7.89713041e-02 -1.67274655 0.00579781 47.50 5.47601723e-02 -1.19487761e-01 1.31438204e-01 -1.14106899 0.01461229 47.75 -4.87071486e-02 -2.14464546e-01 2.19925960e-01 -1.79411866 0.02853965 48.00 -1.21560922e-01 -2.97259917e-01 3.21154972e-01 -1.95898418 0.05802616 48.25 -1.40123350e-01 -3.61690131e-01 3.87884395e-01 -1.94040471 0.07670376 48.50 -1.20756826e-01 -2.51986331e-01 2.79426774e-01 -2.01768196 0.03859545 48.75 -1.09985933e-01 -9.44828012e-03 1.10391012e-01 -3.05589859 0.00499702 49.00 -1.55124676e-01 -5.57931487e-02 1.64853088e-01 -2.79633234 0.01380490 49.25 -6.53792847e-01 -8.82542819e-02 6.59722598e-01 -3.00741557 0.12761213 49.50 -7.61742066e-01 -2.93574725e-01 8.16355984e-01 -2.77373626 0.16746424 49.75 -1.18687686e+00 -5.16994365e-01 1.29458868e+00 -2.73078459 0.23810948 50.00 -1.47635561e+00 -3.77130536e-01 1.52376288e+00 -2.89149406 0.11038919 50.25 -2.96937840e-01 1.91604811e+00 1.93892043e+00 1.72454734 0.06993486 50.50 -2.07206323e-02 9.94253898e-01 9.94469787e-01 1.59163369 0.04248090 50.75 3.15117698e-01 2.83554785e-02 3.16390893e-01 0.08974207 0.01459132 51.00 1.40272364e-01 7.35118186e-02 1.58367685e-01 0.48271365 0.00686628 51.25 8.05964327e-02 1.07525987e-01 1.34378654e-01 0.92758132 0.00730454 51.50 1.79961706e-01 -9.19356365e-04 1.79964054e-01 -0.00510858 0.01813079 51.75 1.33859686e-01 -1.73652900e-01 2.19257258e-01 -0.91408656 0.02654778 52.00 2.18855031e-01 -7.91524757e-02 2.32728681e-01 -0.34702987 0.03056737 52.25 4.04820216e-01 -5.26309398e-02 4.08227171e-01 -0.12928548 0.09308160 52.50 3.42098653e-01 -1.61667218e-02 3.42480439e-01 -0.04722235 0.06427861 52.75 3.26115377e-01 -7.65586756e-02 3.34981298e-01 -0.23058401 0.05622129 53.00 3.02073551e-01 -4.96016197e-02 3.06118850e-01 -0.16275141 0.04446838 53.25 3.11501442e-01 6.99799721e-02 3.19265321e-01 0.22098487 0.04055883 53.50 -2.76489795e-02 2.73055953e-02 3.88595111e-02 2.36244292 0.00098250 53.75 -4.16006369e-02 -3.08676867e-02 5.18018057e-02 -2.50323102 0.00179489 54.00 2.33584820e-01 -6.09550459e-02 2.41407096e-01 -0.25526206 0.03011586 54.25 4.01352609e-01 -4.93102188e-02 4.04370392e-01 -0.12224746 0.07600002 54.50 3.85526481e-01 -2.65523360e-02 3.86439768e-01 -0.06876433 0.07556120 54.75 5.28295796e-01 -5.93805510e-02 5.31622514e-01 -0.11193040 0.13643441 55.00 3.21484586e-01 7.59247585e-02 3.30328485e-01 0.23191968 0.05157673 55.25 2.26093025e-01 1.90769497e-01 2.95822678e-01 0.70086347 0.03754381 55.50 1.88253029e-01 1.47230235e-01 2.38989424e-01 0.66372251 0.03414286 55.75 3.91471943e-01 1.60004892e-01 4.22908793e-01 0.38800637 0.08326218 56.00 3.42567609e-01 6.83959680e-02 3.49328750e-01 0.19706558 0.05869140 56.25 2.41622462e-01 9.06903686e-02 2.58081687e-01 0.35906797 0.03444420 56.50 2.70051543e-01 -1.02865026e-01 2.88979324e-01 -0.36394095 0.03790216 56.75 2.99700725e-01 -9.47394108e-02 3.14318438e-01 -0.30617338 0.03974199 57.00 4.40165824e-01 -3.93595578e-01 5.90477292e-01 -0.72960054 0.15206379 57.25 5.23816243e-01 -3.50961680e-01 6.30521655e-01 -0.59031307 0.18109359 57.50 5.71537210e-01 -1.55093334e-01 5.92206657e-01 -0.26498062 0.16727997 57.75 6.72292892e-01 -1.28433733e-01 6.84450843e-01 -0.18876394 0.20635762 58.00 6.66679709e-01 -3.06414361e-01 7.33724468e-01 -0.43081891 0.19808617 58.25 7.10874795e-01 -2.93226285e-01 7.68976352e-01 -0.39122408 0.21545766 58.50 1.00465796e+00 -5.22219459e-01 1.13227681e+00 -0.47936048 0.39055783 58.75 1.02004423e+00 -4.52637526e-01 1.11596190e+00 -0.41763847 0.32664869 59.00 1.67334456e+00 -4.72401740e-01 1.73874823e+00 -0.27514939 0.58522049 59.25 1.73512895e+00 -4.46312086e-01 1.79161015e+00 -0.25176353 0.58178991 59.50 1.71729054e+00 -3.03477896e-01 1.74389955e+00 -0.17491311 0.65227840 59.75 1.43915034e+00 -2.66582885e-01 1.46363252e+00 -0.18316024 0.53312175 60.00 1.63397501e+00 -4.82142188e-01 1.70362420e+00 -0.28693066 0.52868267 60.25 1.39306950e+00 -4.53323025e-01 1.46497249e+00 -0.31460546 0.47969602 60.50 1.38640750e+00 -5.29961574e-01 1.48424561e+00 -0.36511623 0.46268599 60.75 9.87353166e-01 -5.04687423e-01 1.10886233e+00 -0.47252926 0.31034215 61.00 1.02701253e+00 -5.64967627e-01 1.17215322e+00 -0.50292599 0.32896903 61.25 9.47212800e-01 -2.01554827e-01 9.68419556e-01 -0.20966024 0.24965932 61.50 1.28210118e+00 -3.36858328e-01 1.32561570e+00 -0.25693216 0.43837966 61.75 1.18517843e+00 -3.94701640e-01 1.24917464e+00 -0.32147880 0.40553677 62.00 1.39240219e+00 -5.50546260e-01 1.49729257e+00 -0.37652864 0.54447442 62.25 1.19535168e+00 -4.07646970e-01 1.26294960e+00 -0.32865863 0.42529564 62.50 1.16094733e+00 -3.48195633e-01 1.21203915e+00 -0.29138680 0.41561038 62.75 1.11799850e+00 -4.02166336e-01 1.18813232e+00 -0.34530762 0.42715646 63.00 1.46563960e+00 -3.84693249e-01 1.51528490e+00 -0.25668462 0.58706952 63.25 1.49931051e+00 -4.39144133e-01 1.56229945e+00 -0.28492797 0.55149284 63.50 1.81076229e+00 -5.26538875e-01 1.88576331e+00 -0.28297952 0.69407441 63.75 1.78511359e+00 -4.92062040e-01 1.85168992e+00 -0.26896806 0.63580072 64.00 1.88549250e+00 -6.03968383e-01 1.97986357e+00 -0.30999677 0.65783727 64.25 1.67740038e+00 -4.24732207e-01 1.73033797e+00 -0.24799624 0.50864675 64.50 1.78991262e+00 -4.99000019e-01 1.85816797e+00 -0.27188128 0.52607535 64.75 1.39940204e+00 -2.65982387e-01 1.42445523e+00 -0.18782816 0.40106700 65.00 1.19877412e+00 -3.85328365e-01 1.25918121e+00 -0.31100442 0.34089197 65.25 9.30846559e-01 -3.32151539e-01 9.88331908e-01 -0.34274412 0.24695960 65.50 1.15309604e+00 -3.16028636e-01 1.19561891e+00 -0.26750107 0.27191839 65.75 1.34152118e+00 -2.58208810e-01 1.36614453e+00 -0.19014928 0.31726344 66.00 1.43095573e+00 -4.58953897e-01 1.50275513e+00 -0.31036719 0.36728885 66.25 1.15014510e+00 -4.75545939e-01 1.24457932e+00 -0.39206086 0.28705428 66.50 1.39844487e+00 -5.10972997e-01 1.48887254e+00 -0.35031595 0.36605008 66.75 1.55721594e+00 -6.62172261e-01 1.69215649e+00 -0.40206399 0.44268619 67.00 1.79760624e+00 -6.00436231e-01 1.89523398e+00 -0.32236832 0.50721965 67.25 2.03448971e+00 -9.31490755e-01 2.23759322e+00 -0.42936263 0.46136355 67.50 2.30912499e+00 -9.90366757e-01 2.51254543e+00 -0.40516314 0.51889331 67.75 2.93533141e+00 -9.43107469e-01 3.08311891e+00 -0.31087726 0.55879172 68.00 3.90582624e+00 -1.07853197e+00 4.05200072e+00 -0.26942031 0.63331459 68.25 6.62765715e+00 -1.92618806e+00 6.90188668e+00 -0.28283735 0.73118898 68.50 7.89151102e+00 -3.01609444e+00 8.44824076e+00 -0.36506347 0.71065478 68.75 4.12426443e+00 -6.61121222e+00 7.79215529e+00 -1.01303968 0.33987631 69.00 -1.94131457e+00 -2.78522344e+00 3.39502163e+00 -2.17950937 0.08128813 69.25 -2.48022326e+00 1.66907207e-02 2.48027942e+00 3.13486323 0.29536244 69.50 -1.54298500e+00 -3.67071168e-01 1.58604664e+00 -2.90803729 0.33546479 69.75 -7.48359949e-01 -3.02628113e-02 7.48971595e-01 -3.10117583 0.20366234 70.00 -4.97032137e-01 -2.54363924e-02 4.97682585e-01 -3.09046071 0.15836615 70.25 -1.80426292e-01 5.26151662e-03 1.80502992e-01 3.11243933 0.05720244 70.50 -5.26535848e-02 -3.84635633e-02 6.52061784e-02 -2.51068731 0.01051000 70.75 -1.15738925e-02 -7.76562004e-03 1.39377130e-02 -2.55062356 0.00062533 71.00 2.28131546e-02 -3.30923233e-02 4.01938041e-02 -0.96723414 0.00323762 71.25 1.77267425e-01 4.84326044e-02 1.83764679e-01 0.26670850 0.05485667 71.50 2.26845347e-01 2.03784492e-01 3.04937585e-01 0.73189781 0.10326077 71.75 4.07122124e-01 2.94452242e-01 5.02444571e-01 0.62616205 0.34317234 72.00 5.07728812e-01 2.37830583e-01 5.60670967e-01 0.43806638 0.42745178 72.25 6.34946408e-01 1.89690531e-01 6.62675968e-01 0.29031003 0.61988934 72.50 6.86390088e-01 1.54703678e-01 7.03608258e-01 0.22168315 0.64047789 72.75 7.17189346e-01 1.64969574e-01 7.35918146e-01 0.22608961 0.72245120 73.00 6.57641175e-01 1.63622974e-01 6.77690484e-01 0.24385158 0.62430152 73.25 6.18519784e-01 1.11528304e-01 6.28494459e-01 0.17839789 0.73698653 73.50 6.56461138e-01 1.26553434e-01 6.68548425e-01 0.19044497 0.79364328 73.75 6.81091008e-01 1.53698750e-01 6.98217922e-01 0.22194779 0.85640182 74.00 6.15577230e-01 1.36651890e-01 6.30562499e-01 0.21844749 0.76924239 74.25 5.70645126e-01 1.40943200e-01 5.87793200e-01 0.24214300 0.79150239 74.50 4.74724178e-01 1.60022664e-01 5.00969358e-01 0.32512375 0.59237107 74.75 4.68874368e-01 1.46968200e-01 4.91368319e-01 0.30374920 0.64758830 75.00 4.67215101e-01 1.34727316e-01 4.86252404e-01 0.28074629 0.44646232 75.25 3.80054065e-01 1.14677086e-01 3.96978496e-01 0.29305133 0.29636160 75.50 2.11125661e-01 2.72565385e-01 3.44769393e-01 0.91174420 0.14305819 75.75 1.41073164e-01 3.99346333e-01 4.23531736e-01 1.23122006 0.19238046 76.00 7.47891733e-02 4.72646049e-01 4.78526602e-01 1.41386243 0.15541281 76.25 4.41904079e-03 5.72755263e-01 5.72772310e-01 1.56308107 0.19613565 76.50 1.80621970e-01 5.63369729e-01 5.91616216e-01 1.26054014 0.11063502 76.75 6.52882247e-01 3.20866444e-01 7.27468558e-01 0.45679345 0.12496207 77.00 1.23252342e+00 2.14953896e-01 1.25112716e+00 0.17266486 0.56404978 77.25 1.05195375e+00 2.16823415e-01 1.07406661e+00 0.20326836 0.61792513 77.50 7.07442434e-01 2.23841927e-01 7.42010785e-01 0.30644311 0.51321562 77.75 5.00326982e-01 4.28798583e-01 6.58934984e-01 0.70856507 0.41585013 78.00 1.31130916e-01 1.23966835e+00 1.24658451e+00 1.46540920 0.49929873 78.25 3.59257647e-01 1.71491147e+00 1.75213796e+00 1.36429217 0.56499631 78.50 1.29299790e+00 1.65280888e+00 2.09848059e+00 0.90693957 0.60162509 78.75 1.40154588e+00 1.22531311e+00 1.86164526e+00 0.71840976 0.56059669 79.00 1.35352438e+00 6.84805515e-01 1.51690041e+00 0.46839030 0.52317365 79.25 1.21357369e+00 5.74538488e-01 1.34270458e+00 0.44216408 0.48639400 79.50 1.14105680e+00 4.82785012e-01 1.23898830e+00 0.40026311 0.52874567 79.75 1.06839789e+00 4.24684681e-01 1.14970915e+00 0.37834653 0.44189365 80.00 9.64395441e-01 4.73780678e-01 1.07448904e+00 0.45664103 0.40894627 80.25 7.05784565e-01 4.42367393e-01 8.32959040e-01 0.55987396 0.26643939 80.50 6.83545407e-01 6.61540478e-01 9.51246618e-01 0.76904013 0.32413134 80.75 7.73699581e-01 5.19626984e-01 9.31999595e-01 0.59141943 0.29790870 81.00 4.85794751e-01 3.92929638e-01 6.24812164e-01 0.68010726 0.19331489 81.25 4.04126733e-01 5.12217753e-01 6.52445740e-01 0.90281452 0.18951977 81.50 2.23061938e-01 8.56968454e-01 8.85523326e-01 1.31615488 0.27455258 81.75 3.09252930e-01 7.01503535e-01 7.66645019e-01 1.15558340 0.14955610 82.00 3.34947406e-01 7.58161147e-01 8.28853479e-01 1.15479145 0.15036408 82.25 3.08157794e-01 7.24012196e-01 7.86863956e-01 1.16839630 0.11456647 82.50 6.85285438e-01 6.86968957e-01 9.70331118e-01 0.78662499 0.10464398 82.75 9.08799048e-01 4.11379514e-01 9.97571458e-01 0.42506610 0.12841106 83.00 1.34485446e+00 7.83648888e-01 1.55651505e+00 0.52760300 0.27217078 83.25 1.10898805e+00 7.22544624e-01 1.32360312e+00 0.57745361 0.26927318 83.50 1.18102328e+00 6.51919895e-01 1.34900539e+00 0.50437420 0.31056818 83.75 1.06958178e+00 5.19947304e-01 1.18926464e+00 0.45248375 0.28243427 84.00 1.21543862e+00 5.50354124e-01 1.33423413e+00 0.42518237 0.31582457 84.25 1.12982236e+00 4.42946785e-01 1.21354869e+00 0.37363414 0.24906278 84.50 1.48544349e+00 1.86714942e-01 1.49713221e+00 0.12504065 0.37127908 84.75 1.45466471e+00 3.49164085e-01 1.49598295e+00 0.23557394 0.39544970 85.00 1.65309465e+00 6.55333226e-01 1.77825296e+00 0.37742339 0.47737800 85.25 1.57388766e+00 1.84673150e-01 1.58468500e+00 0.11680159 0.43033771 85.50 1.54155883e+00 9.18555225e-03 1.54158619e+00 0.00595854 0.48518081 85.75 1.39804005e+00 2.93598949e-01 1.42853643e+00 0.20699941 0.46373506 86.00 1.62480471e+00 5.46132136e-01 1.71413262e+00 0.32425799 0.58525406 86.25 1.32492206e+00 6.24720314e-01 1.46481874e+00 0.44060086 0.46726968 86.50 1.24364944e+00 4.89546421e-01 1.33653268e+00 0.37500902 0.44941725 86.75 1.12897518e+00 5.92867942e-01 1.27517738e+00 0.48355530 0.44716426 87.00 9.36509666e-01 6.92881524e-01 1.16496144e+00 0.63697674 0.43640981 87.25 4.77075401e-01 5.56124956e-01 7.32718162e-01 0.86175881 0.18508040 87.50 1.92686443e-01 6.29021041e-01 6.57871974e-01 1.27354464 0.11068668 87.75 2.10667800e-01 4.35850008e-01 4.84093123e-01 1.12055778 0.03060099 88.00 5.24794869e-01 3.08863728e-01 6.08938795e-01 0.53195176 0.03604721 88.25 1.03556432e+00 -2.02471325e-01 1.05517207e+00 -0.19308212 0.08866592 88.50 9.21512606e-01 -9.92248351e-02 9.26839280e-01 -0.10726278 0.08991524 88.75 8.62545301e-01 -5.84483754e-01 1.04192402e+00 -0.59555201 0.18671255 89.00 8.55811562e-01 -7.10551323e-01 1.11233835e+00 -0.69292537 0.20952108 89.25 8.85829932e-01 -8.95162480e-01 1.25936910e+00 -0.79063820 0.31569500 89.50 9.91211176e-01 -7.74363695e-01 1.25783096e+00 -0.66319044 0.35362077 89.75 9.37535862e-01 -5.76210307e-01 1.10045073e+00 -0.55108628 0.43666087 90.00 9.06701232e-01 -3.25877690e-01 9.63485025e-01 -0.34503337 0.40791738 90.25 1.01704162e+00 1.51667511e-01 1.02828824e+00 0.14803523 0.43912226 90.50 1.32530265e+00 3.38671134e-01 1.36789080e+00 0.25018828 0.55308398 90.75 1.84112073e+00 1.75722920e-01 1.84948752e+00 0.09515521 0.78632360 91.00 1.89208329e+00 6.74600986e-02 1.89328552e+00 0.03563878 0.83051987 91.25 2.02454528e+00 -6.60144548e-02 2.02562127e+00 -0.03259550 0.88834428 91.50 1.83688212e+00 1.41178392e-01 1.84229945e+00 0.07670682 0.82269541 91.75 1.94661432e+00 5.40215795e-01 2.02018326e+00 0.27070342 0.88718267 92.00 2.26384508e+00 5.94098517e-01 2.34050157e+00 0.25664187 0.92186216 92.25 2.39786299e+00 5.12419656e-01 2.45200343e+00 0.21053180 0.95256328 92.50 2.28007706e+00 3.81191512e-01 2.31172195e+00 0.16565161 0.90132706 92.75 2.08097254e+00 2.44944913e-01 2.09533881e+00 0.11716781 0.86002562 93.00 2.00708425e+00 2.55992796e-01 2.02334365e+00 0.12685968 0.85489278 93.25 2.04778325e+00 2.60239023e-01 2.06425303e+00 0.12640570 0.87563887 93.50 2.08376026e+00 2.93561506e-01 2.10433723e+00 0.13995956 0.84021324 93.75 2.27112553e+00 2.85420509e-01 2.28899018e+00 0.12501817 0.90525732 94.00 2.24080418e+00 1.19599997e-01 2.24399365e+00 0.05332310 0.90052485 94.25 2.24939711e+00 1.06427687e-01 2.25191345e+00 0.04727861 0.94492451 94.50 2.19692578e+00 3.12462857e-02 2.19714798e+00 0.01422177 0.92743468 94.75 2.13325573e+00 -1.88074369e-02 2.13333863e+00 -0.00881608 0.94246457 95.00 2.03914458e+00 2.82602810e-02 2.03934040e+00 0.01385800 0.92260760 95.25 1.97800992e+00 2.17274082e-02 1.97812925e+00 0.01098404 0.92555156 95.50 1.95779906e+00 7.26646953e-02 1.95914709e+00 0.03709847 0.89243807 95.75 1.99712504e+00 7.85249274e-02 1.99866820e+00 0.03929874 0.92265888 96.00 2.02050225e+00 8.32703834e-02 2.02221742e+00 0.04118941 0.89489387 96.25 2.05837723e+00 1.24609789e-01 2.06214559e+00 0.06046409 0.90679553 96.50 1.93009662e+00 2.72834209e-02 1.93028944e+00 0.01413484 0.89917019 96.75 1.86073662e+00 -9.23172868e-03 1.86075952e+00 -0.00496129 0.90475611 97.00 1.80232468e+00 -7.15045555e-02 1.80374254e+00 -0.03965272 0.91821069 97.25 1.74406136e+00 -4.17572535e-02 1.74456118e+00 -0.02393796 0.93062867 97.50 1.43762782e+00 2.27800589e-03 1.43762962e+00 0.00158456 0.88108299 97.75 1.25539415e+00 1.15869542e-01 1.26073003e+00 0.09203659 0.84707977 98.00 8.50846841e-01 4.69756889e-01 9.71911457e-01 0.50445798 0.61558143 98.25 6.49170876e-01 7.91879182e-01 1.02396068e+00 0.88410710 0.34857365 98.50 2.35316038e+00 2.50438226e+00 3.43646537e+00 0.81651947 0.66420421 98.75 3.43665006e+00 1.97183229e+00 3.96215677e+00 0.52090626 0.74986434 99.00 3.39750586e+00 -2.31566055e-01 3.40538822e+00 -0.06805241 0.88354293 99.25 2.98419470e+00 -4.42038651e-01 3.01675590e+00 -0.14705728 0.90591070 99.50 1.93542019e+00 -1.05631573e-01 1.93830063e+00 -0.05452401 0.87831639 99.75 1.69753785e+00 8.11446121e-02 1.69947616e+00 0.04776500 0.85520684 100.00 1.50646169e+00 7.06295165e-01 1.66381480e+00 0.43841343 0.86032130 100.25 1.66009924e+00 9.02052368e-01 1.88934591e+00 0.49774073 0.87932103 100.50 2.35828968e+00 1.16151359e+00 2.62881038e+00 0.45764871 0.95702296 100.75 2.47110450e+00 1.10886351e+00 2.70849326e+00 0.42179891 0.96553430 101.00 2.62789434e+00 1.07081326e+00 2.83768738e+00 0.38693761 0.97413120 101.25 2.76806322e+00 1.03469910e+00 2.95512711e+00 0.35771727 0.97113319 101.50 2.98388260e+00 9.55358975e-01 3.13309211e+00 0.30985997 0.98036822 101.75 3.06620477e+00 8.73964902e-01 3.18832658e+00 0.27766828 0.97301986 102.00 3.16527003e+00 7.52689200e-01 3.25353275e+00 0.23346017 0.97719463 102.25 3.25942028e+00 5.95434253e-01 3.31336121e+00 0.18068861 0.97951629 102.50 3.30277036e+00 3.51693346e-01 3.32144250e+00 0.10608459 0.98198824 102.75 3.20308759e+00 2.41661037e-01 3.21219086e+00 0.07530361 0.98136103 103.00 3.14252610e+00 2.79462384e-01 3.15492781e+00 0.08869589 0.98747439 103.25 3.23469571e+00 2.03546736e-01 3.24109358e+00 0.06284323 0.98681459 103.50 3.29959553e+00 9.35725381e-02 3.30092206e+00 0.02835119 0.99137708 103.75 3.38022139e+00 1.12867443e-01 3.38210521e+00 0.03337815 0.98821851 104.00 3.43661290e+00 6.79572002e-02 3.43728475e+00 0.01977189 0.99296478 104.25 3.43988142e+00 2.00195848e-02 3.43993967e+00 0.00581978 0.99235786 104.50 3.57189649e+00 -5.31175931e-03 3.57190044e+00 -0.00148710 0.99109201 104.75 3.62175995e+00 -3.24886602e-01 3.63630258e+00 -0.08946461 0.98580177 105.00 3.60914440e+00 -5.86011708e-01 3.65640985e+00 -0.16096388 0.99021711 105.25 3.47283345e+00 -7.13254874e-01 3.54532152e+00 -0.20256444 0.98826495 105.50 3.36633281e+00 -7.83161567e-01 3.45623185e+00 -0.22857934 0.99205068 105.75 3.17615743e+00 -7.61793094e-01 3.26623710e+00 -0.23540068 0.99126076 106.00 3.13597370e+00 -6.77081198e-01 3.20823471e+00 -0.21264369 0.99431196 106.25 3.29587128e+00 -5.06446788e-01 3.33455482e+00 -0.15246842 0.99057826 106.50 3.47163844e+00 -4.60519393e-01 3.50204962e+00 -0.13188193 0.99150754 106.75 3.79041025e+00 -5.22148995e-01 3.82620562e+00 -0.13689369 0.97963166 107.00 4.02811778e+00 -8.77185078e-01 4.12252187e+00 -0.21441796 0.96506795 107.25 3.83829628e+00 -1.44457577e+00 4.10113612e+00 -0.35996123 0.97645787 107.50 3.81909448e+00 -1.59157151e+00 4.13746088e+00 -0.39485407 0.98630399 107.75 3.83509738e+00 -1.86954426e+00 4.26651704e+00 -0.45358385 0.97847680 108.00 3.86389162e+00 -2.13686779e+00 4.41541191e+00 -0.50517045 0.97411115 108.25 3.53160224e+00 -2.79992039e+00 4.50685795e+00 -0.67034675 0.95589554 108.50 3.21665950e+00 -3.09179166e+00 4.46162236e+00 -0.76560701 0.95675211 108.75 2.22756715e+00 -3.53388152e+00 4.17736449e+00 -1.00836212 0.91742527 109.00 1.74450739e+00 -3.52881890e+00 3.93647925e+00 -1.11167078 0.92670577 109.25 1.45551896e+00 -3.08518884e+00 3.41129383e+00 -1.12998153 0.93771687 109.50 1.18857737e+00 -3.10448443e+00 3.32423521e+00 -1.20515412 0.91873401 109.75 6.08915745e-01 -2.75662201e+00 2.82307338e+00 -1.35339536 0.88214319 110.00 5.83032029e-01 -2.39484311e+00 2.46479206e+00 -1.33198886 0.72122067 110.25 4.48199172e-01 -3.36740551e+00 3.39710206e+00 -1.43847479 0.47479835 110.50 -1.31642814e+00 -3.01479033e+00 3.28967229e+00 -1.98249866 0.51499223 110.75 -1.16346141e+00 -1.48246996e+00 1.88450514e+00 -2.23620794 0.74647811 111.00 -9.65372905e-01 -1.14994395e+00 1.50143796e+00 -2.26916036 0.67508635 111.25 -6.12138520e-01 -6.07159898e-01 8.62181368e-01 -2.36027765 0.42625517 111.50 -4.23266327e-01 -4.27399306e-01 6.01518537e-01 -2.35133600 0.21155638 111.75 -1.78335005e-01 1.01734697e-01 2.05312744e-01 2.62316977 0.03802230 112.00 5.30532096e-02 3.03151080e-01 3.07758380e-01 1.39754499 0.09407088 112.25 1.63089065e-01 3.36687373e-01 3.74107512e-01 1.11971195 0.22784092 112.50 2.80164023e-01 6.20937530e-01 6.81216042e-01 1.14694893 0.41647920 112.75 5.31671969e-01 1.02372147e+00 1.15355135e+00 1.09178711 0.75796163 113.00 9.16930858e-01 1.21721892e+00 1.52393704e+00 0.92518664 0.80273438 113.25 1.54989205e+00 1.25012974e+00 1.99122819e+00 0.67874724 0.89675929 113.50 1.99298514e+00 9.05567177e-01 2.18907325e+00 0.42648811 0.93323095 113.75 2.30240101e+00 6.18448935e-01 2.38401542e+00 0.26241623 0.97494056 114.00 2.29213958e+00 3.23341885e-01 2.31483344e+00 0.14014084 0.95737732 114.25 2.15346506e+00 -9.59434313e-02 2.15560128e+00 -0.04452360 0.96804136 114.50 2.01131891e+00 -1.63178747e-01 2.01792741e+00 -0.08095292 0.96396064 114.75 1.90622241e+00 -1.61307598e-01 1.91303529e+00 -0.08442048 0.96400091 115.00 1.85998209e+00 -8.41707478e-02 1.86188563e+00 -0.04522267 0.93350509 115.25 1.82197738e+00 4.88185021e-02 1.82263129e+00 0.02678783 0.92849682 115.50 1.87314559e+00 6.77545615e-02 1.87437059e+00 0.03615578 0.91360392 115.75 1.91783554e+00 1.35269257e-01 1.92260004e+00 0.07041564 0.91620353 116.00 2.08457077e+00 1.98951283e-01 2.09404319e+00 0.09515172 0.91703703 116.25 2.19833001e+00 2.12643871e-01 2.20859056e+00 0.09642973 0.95127670 116.50 2.49332889e+00 3.61750468e-02 2.49359131e+00 0.01450772 0.93845967 116.75 2.66361777e+00 -1.66959791e-01 2.66884530e+00 -0.06259969 0.94944527 117.00 2.42215243e+00 -4.09524113e-01 2.45652853e+00 -0.16749048 0.92307600 117.25 2.27950255e+00 -2.45785871e-01 2.29271511e+00 -0.10740938 0.91897624 117.50 2.63333596e+00 1.03596055e-01 2.63537291e+00 0.03931996 0.93669650 117.75 2.92131828e+00 7.03685898e-02 2.92216568e+00 0.02408330 0.95203258 118.00 3.61727478e+00 -3.00556053e-01 3.62973977e+00 -0.08289866 0.95014290 118.25 4.07996921e+00 -7.58369887e-01 4.14985225e+00 -0.18377901 0.93937216 118.50 4.33077998e+00 -2.01104100e+00 4.77492839e+00 -0.43473133 0.86819908 118.75 3.24393659e+00 -3.04444955e+00 4.44879733e+00 -0.75368571 0.77061423 119.00 8.26411712e-01 -2.55331064e+00 2.68371972e+00 -1.25777434 0.71062414 119.25 7.77475285e-01 -1.61366540e+00 1.79119621e+00 -1.12180876 0.69107343 119.50 1.33591127e+00 -6.67585019e-01 1.49342850e+00 -0.46342564 0.76013434 119.75 1.75795879e+00 -5.41587256e-01 1.83949337e+00 -0.29885062 0.87380954 120.00 2.21723645e+00 -6.04867917e-01 2.29826079e+00 -0.26632218 0.93185129 120.25 2.41971304e+00 -6.51215925e-01 2.50581192e+00 -0.26290021 0.92646939 120.50 3.00387607e+00 -9.74651060e-01 3.15803991e+00 -0.31374746 0.93720268 120.75 3.12373072e+00 -1.20583014e+00 3.34839065e+00 -0.36839899 0.92278297 121.00 3.17311423e+00 -1.76263321e+00 3.62981126e+00 -0.50704841 0.92227399 121.25 3.03372358e+00 -1.98541491e+00 3.62565182e+00 -0.57949589 0.90501748 121.50 2.82144966e+00 -1.79225204e+00 3.34256572e+00 -0.56591752 0.91191807 121.75 3.24819802e+00 -1.75959470e+00 3.69417974e+00 -0.49645943 0.87944289 122.00 4.38583545e+00 -2.62283348e+00 5.11026497e+00 -0.53896506 0.91415780 122.25 4.35011960e+00 -3.47480062e+00 5.56756499e+00 -0.67399829 0.86786567 122.50 3.85959357e+00 -5.68190948e+00 6.86881051e+00 -0.97411385 0.86769531 122.75 3.14598347e+00 -6.75640361e+00 7.45293242e+00 -1.13502087 0.80191913 123.00 4.39323221e-01 -9.00933541e+00 9.02004043e+00 -1.52207181 0.74647557 123.25 -3.74533821e+00 -8.10216386e+00 8.92595191e+00 -2.00380202 0.66703012 123.50 -6.94788977e+00 -3.92064799e+00 7.97775989e+00 -2.62784193 0.66983710 123.75 -4.60515189e+00 -1.26794580e+00 4.77651656e+00 -2.87291779 0.53797508 124.00 -2.61342092e+00 -1.31086211e-01 2.61670642e+00 -3.09147580 0.64385245 124.25 -2.01811885e+00 -4.45391271e-01 2.06668263e+00 -2.92437833 0.59973979 124.50 -1.64062004e+00 -7.17861395e-01 1.79079845e+00 -2.72913610 0.76173433 124.75 -1.80016456e+00 -6.47095767e-01 1.91293632e+00 -2.79651096 0.80132973 125.00 -1.78157738e+00 -4.08779835e-01 1.82787278e+00 -2.91604834 0.82948850 125.25 -1.49658013e+00 -1.33156738e-01 1.50249220e+00 -3.05285232 0.75371544 125.50 -1.22932700e+00 9.28069161e-02 1.23282521e+00 3.06624150 0.79867685 125.75 -9.82338496e-01 3.17528838e-01 1.03238243e+00 2.82895552 0.72403927 126.00 -9.09420404e-01 3.99480834e-01 9.93292710e-01 2.72769779 0.79041825 126.25 -6.15858392e-01 5.31461127e-01 8.13469414e-01 2.42962262 0.65957520 126.50 -3.88458213e-01 6.65215984e-01 7.70332453e-01 2.09933674 0.71557020 126.75 -2.39336379e-02 5.54341762e-01 5.54858188e-01 1.61394441 0.56579333 127.00 1.99009169e-01 3.92927884e-01 4.40450873e-01 1.10198008 0.52294358 127.25 9.36554719e-02 3.58262398e-02 1.00273959e-01 0.36535789 0.04113382 127.50 -1.86061016e-01 3.47577802e-02 1.89279700e-01 2.95691280 0.15157915 127.75 -2.93659996e-01 3.24962434e-01 4.37991755e-01 2.30563738 0.55687190 128.00 -2.03145508e-01 4.51039647e-01 4.94676521e-01 1.99397778 0.68501043 128.25 8.29634028e-02 4.97284801e-01 5.04157812e-01 1.40548604 0.70557254 128.50 1.78137476e-01 5.35970066e-01 5.64798081e-01 1.24991789 0.81439785 128.75 3.24969793e-01 5.73177974e-01 6.58891764e-01 1.05502424 0.78649970 129.00 5.19751621e-01 5.89521487e-01 7.85924507e-01 0.84821234 0.83509124 129.25 6.78730138e-01 4.46122985e-01 8.12219378e-01 0.58148341 0.90181255 129.50 6.89128115e-01 4.02835949e-01 7.98232022e-01 0.52898835 0.92491958 129.75 7.66158681e-01 3.01067708e-01 8.23189462e-01 0.37442045 0.94708779 130.00 7.96946816e-01 2.63074247e-01 8.39245069e-01 0.31884012 0.95755400 130.25 8.42158292e-01 2.28695572e-01 8.72658154e-01 0.26516423 0.96364367 130.50 8.82774611e-01 1.93869587e-01 9.03812166e-01 0.21618201 0.94943257 130.75 1.03820385e+00 1.06545460e-02 1.03825852e+00 0.01026212 0.95771343 131.00 9.99818261e-01 -1.24969764e-01 1.00759813e+00 -0.12434759 0.96274100 131.25 8.17754410e-01 -2.51857947e-01 8.55660388e-01 -0.29876836 0.97101750 131.50 7.78340295e-01 -2.03605150e-01 8.04530094e-01 -0.25585574 0.96683424 131.75 7.66226570e-01 -1.10595358e-01 7.74166965e-01 -0.14334767 0.96916372 132.00 7.72893033e-01 -1.28298732e-01 7.83469339e-01 -0.16449806 0.96731486 132.25 7.88150165e-01 -2.05416487e-01 8.14479353e-01 -0.25495916 0.96603065 132.50 7.42513408e-01 -2.59630141e-01 7.86596447e-01 -0.33637538 0.93912470 132.75 6.53482803e-01 -3.02967485e-01 7.20297904e-01 -0.43412215 0.91879389 133.00 6.71850301e-01 -3.38738933e-01 7.52414042e-01 -0.46699248 0.92748967 133.25 6.18146989e-01 -3.94050347e-01 7.33063010e-01 -0.56751651 0.93671496 133.50 5.33421067e-01 -4.13315983e-01 6.74809704e-01 -0.65921010 0.90705219 133.75 4.13174482e-01 -3.83318929e-01 5.63601414e-01 -0.74793196 0.90032149 134.00 3.16415185e-01 -3.45444599e-01 4.68455484e-01 -0.82923044 0.73323301 134.25 9.58652201e-02 -1.81228254e-01 2.05021512e-01 -1.08423829 0.26632502 134.50 1.54185407e-01 4.93223225e-02 1.61882152e-01 0.30960288 0.28588624 134.75 3.03693770e-01 1.71760924e-01 3.48900732e-01 0.51472060 0.83950783 135.00 4.02829020e-01 1.97353823e-01 4.48575246e-01 0.45555080 0.90974993 135.25 4.70837901e-01 2.14455382e-01 5.17377463e-01 0.42739846 0.96873809 135.50 5.43744390e-01 2.02074435e-01 5.80079338e-01 0.35581726 0.95916521 135.75 6.49331103e-01 2.01120301e-01 6.79764854e-01 0.30036351 0.97604473 136.00 6.79966242e-01 1.54084563e-01 6.97205954e-01 0.22284271 0.97657083 136.25 6.91071215e-01 1.44299764e-01 7.05975811e-01 0.20584828 0.98738407 136.50 7.18151732e-01 1.48408007e-01 7.33325881e-01 0.20378414 0.98501732 136.75 7.47073786e-01 1.48956957e-01 7.61779113e-01 0.19680627 0.98673827 137.00 8.26947022e-01 1.81500970e-01 8.46630958e-01 0.21605730 0.97832479 137.25 9.19356642e-01 2.24434193e-01 9.46354765e-01 0.23943781 0.98272312 137.50 1.07717238e+00 2.06336082e-01 1.09675654e+00 0.18926084 0.96464530 137.75 1.23679095e+00 1.23088653e-01 1.24290091e+00 0.09919596 0.96424746 138.00 1.37717495e+00 -7.08191872e-02 1.37899463e+00 -0.05137827 0.92003609 138.25 1.48975364e+00 -3.13606726e-01 1.52240437e+00 -0.20747976 0.91595377 138.50 1.25869340e+00 -7.14355279e-01 1.44727763e+00 -0.51620767 0.82557506 138.75 1.06164141e+00 -9.16725701e-01 1.40266479e+00 -0.71227859 0.83251329 139.00 5.52977841e-01 -1.09365049e+00 1.22550230e+00 -1.10265826 0.77877967 139.25 3.16883221e-01 -1.15790990e+00 1.20048753e+00 -1.30366862 0.81978308 139.50 3.35011581e-02 -1.05384273e+00 1.05437509e+00 -1.53901751 0.78543974 139.75 -1.74887720e-01 -9.70992826e-01 9.86616837e-01 -1.74899801 0.79194324 140.00 -3.40453971e-01 -6.52463427e-01 7.35946621e-01 -2.05172971 0.72461989 140.25 -3.71328403e-01 -4.80915930e-01 6.07589430e-01 -2.22830927 0.67194514 140.50 -4.79633176e-01 -2.38237234e-01 5.35541747e-01 -2.68058278 0.61424996 140.75 -5.80368741e-01 -1.04599302e-01 5.89719331e-01 -2.96327787 0.69973180 141.00 -6.88289054e-01 9.33544094e-02 6.94591151e-01 3.00678274 0.78766197 141.25 -6.87029748e-01 2.98697631e-01 7.49152955e-01 2.73147872 0.74608166 141.50 -4.37813976e-01 8.48621007e-01 9.54902451e-01 2.04709255 0.77534154 141.75 -1.11071245e-01 1.09818098e+00 1.10378363e+00 1.67159466 0.79235126 142.00 6.17760937e-01 1.11063507e+00 1.27088113e+00 1.06318782 0.82906262 142.25 8.38223252e-01 7.45685992e-01 1.12190277e+00 0.72704116 0.79955403 142.50 9.04689561e-01 1.27985775e-01 9.13697740e-01 0.14053668 0.81638087 142.75 7.53175138e-01 -5.94472972e-02 7.55517551e-01 -0.07876562 0.75932744 143.00 4.01495828e-01 -1.61434304e-01 4.32735409e-01 -0.38230004 0.60808069 143.25 2.79620200e-01 -1.59535997e-01 3.21930413e-01 -0.51848003 0.45528896 143.50 1.84415695e-01 -1.30224820e-01 2.25760165e-01 -0.61484040 0.22778385 143.75 9.99222699e-02 -2.91926623e-02 1.04099335e-01 -0.28424291 0.04677002 144.00 7.72747103e-03 6.51369083e-02 6.55936783e-02 1.45271394 0.03091272 144.25 -8.12432569e-02 8.23751571e-02 1.15698458e-01 2.34927667 0.06835099 144.50 -2.92663607e-01 5.87456459e-02 2.98501320e-01 2.94349763 0.37296826 144.75 -3.69695163e-01 1.24184733e-01 3.89995336e-01 2.81752385 0.46650585 145.00 -4.01104122e-01 2.31942758e-01 4.63337846e-01 2.61731131 0.52968219 145.25 -5.09106393e-01 3.58634587e-01 6.22742392e-01 2.52789346 0.57998308 145.50 -6.33291128e-01 5.22458640e-01 8.20987626e-01 2.45179875 0.67855404 145.75 -7.16819633e-01 7.92991031e-01 1.06895517e+00 2.30578627 0.69142908 146.00 -6.04117185e-01 1.30475778e+00 1.43782837e+00 2.00441736 0.72626403 146.25 -4.45789860e-01 1.70943148e+00 1.76660255e+00 1.82589722 0.77093456 146.50 -3.25297385e-01 1.93134567e+00 1.95854908e+00 1.73766061 0.86982434 146.75 -7.37147790e-02 2.00480529e+00 2.00616004e+00 1.60754882 0.86593503 147.00 -1.07032314e-01 2.11128023e+00 2.11399151e+00 1.62144842 0.88055116 147.25 1.20614074e-01 2.62244983e+00 2.62522206e+00 1.52483582 0.85026950 147.50 5.01434602e-01 3.41815784e+00 3.45474163e+00 1.42513794 0.86393427 147.75 1.93138210e+00 3.23788292e+00 3.77016214e+00 1.03295776 0.80152188 148.00 2.91138137e+00 2.51418687e+00 3.84672291e+00 0.71232062 0.85834846 148.25 2.81931545e+00 1.32894968e+00 3.11683282e+00 0.44048502 0.81297750 148.50 2.70449729e+00 7.35415168e-01 2.80270246e+00 0.26550336 0.88715855 148.75 2.42179611e+00 4.76492831e-01 2.46822645e+00 0.19427038 0.89283027 149.00 2.20712425e+00 3.26563100e-01 2.23115237e+00 0.14689291 0.93113908 149.25 1.99595370e+00 1.74581984e-01 2.00357431e+00 0.08724591 0.92127404 149.50 1.90263283e+00 8.96939480e-02 1.90474584e+00 0.04710714 0.93458462 149.75 1.85092861e+00 -8.66958216e-02 1.85295787e+00 -0.04680489 0.93367158 150.00 1.80527775e+00 -1.44196322e-01 1.81102743e+00 -0.07970565 0.92550912 150.25 1.61858501e+00 -1.90743148e-01 1.62978538e+00 -0.11730459 0.90458608 150.50 1.48416014e+00 -1.70784573e-01 1.49395404e+00 -0.11456762 0.90293348 150.75 1.24503784e+00 -1.49620651e-01 1.25399584e+00 -0.11960004 0.85686086 151.00 1.12924043e+00 -1.47375250e-01 1.13881667e+00 -0.12977483 0.84369616 151.25 1.09267543e+00 -1.62695990e-01 1.10472150e+00 -0.14781095 0.85054698 151.50 1.04970624e+00 -9.56305675e-02 1.05405331e+00 -0.09085143 0.82723995 151.75 1.10008791e+00 2.36975148e-02 1.10034312e+00 0.02153814 0.83038885 152.00 1.10283992e+00 5.85712487e-02 1.10439417e+00 0.05305963 0.79520222 152.25 1.06133663e+00 1.10027617e-01 1.06702461e+00 0.10329991 0.70837449 152.50 1.20700057e+00 8.53311511e-02 1.21001313e+00 0.07057943 0.73981970 152.75 1.36591627e+00 1.34003927e-02 1.36598200e+00 0.00981024 0.87337932 153.00 1.38159393e+00 -1.80302504e-02 1.38171157e+00 -0.01304958 0.91362865 153.25 1.35104032e+00 -1.02697983e-01 1.35493794e+00 -0.07586810 0.91569790 153.50 1.28554204e+00 -1.68204035e-01 1.29649950e+00 -0.13010380 0.89738520 153.75 1.24051726e+00 -2.21446990e-01 1.26012771e+00 -0.17665109 0.91163774 154.00 1.29755783e+00 -2.61454829e-01 1.32363702e+00 -0.19883517 0.91430556 154.25 1.35941283e+00 -3.64290650e-01 1.40737732e+00 -0.26182484 0.90191997 154.50 1.32716105e+00 -4.10815885e-01 1.38928980e+00 -0.30019038 0.87157714 154.75 1.26617556e+00 -5.07756761e-01 1.36419115e+00 -0.38138200 0.86481437 155.00 1.26555776e+00 -5.46931861e-01 1.37868448e+00 -0.40792517 0.80154017 155.25 1.22844441e+00 -4.84698210e-01 1.32060896e+00 -0.37581018 0.67501304 155.50 9.63054200e-01 -4.70629518e-01 1.07189810e+00 -0.45455418 0.50458088 155.75 8.23893118e-01 -4.28924840e-01 9.28857572e-01 -0.47999728 0.49656353 156.00 9.08777775e-01 -4.05422940e-01 9.95110448e-01 -0.41962172 0.46589459 156.25 1.08212405e+00 -6.26445616e-01 1.25037057e+00 -0.52476306 0.61458497 156.50 9.63254062e-01 -3.80735882e-01 1.03576938e+00 -0.37641358 0.32750430 156.75 7.46820361e-01 1.71782581e-01 7.66322326e-01 0.22608606 0.15108049 157.00 8.96661863e-01 -1.60157806e-01 9.10852908e-01 -0.17675167 0.29234334 157.25 9.03758651e-01 -5.10025022e-01 1.03774044e+00 -0.51378431 0.40386491 157.50 9.48935871e-01 -5.94625542e-01 1.11984768e+00 -0.55976594 0.38179961 157.75 8.30435593e-01 -7.79372641e-01 1.13887883e+00 -0.75368890 0.34485683 158.00 6.62517283e-01 -1.05289979e+00 1.24399643e+00 -1.00916021 0.35813014 158.25 4.12119819e-01 -1.11951271e+00 1.19295911e+00 -1.21806726 0.30559436 158.50 -7.84482003e-01 -6.39068577e-01 1.01184023e+00 -2.45798982 0.19944603 158.75 -1.26754401e+00 -2.51260288e-01 1.29220724e+00 -2.94590336 0.34490468 159.00 -7.10661947e-01 1.91337599e-01 7.35969076e-01 2.87859066 0.22140328 159.25 -3.44058688e-01 3.82789102e-01 5.14688136e-01 2.30295938 0.16702297 159.50 2.30175298e-01 2.52750097e-01 3.41852716e-01 0.83211009 0.09580780 159.75 4.80680777e-01 2.32639982e-01 5.34018137e-01 0.45074984 0.28029907 160.00 8.86432713e-01 -1.33841525e-01 8.96480066e-01 -0.14985697 0.59486473 160.25 9.98355968e-01 -3.87129427e-01 1.07078655e+00 -0.36991635 0.71228532 160.50 1.00323351e+00 -8.49156520e-01 1.31436078e+00 -0.70241179 0.79590439 160.75 1.00501800e+00 -9.74189039e-01 1.39968048e+00 -0.76982300 0.82600365 161.00 9.32467528e-01 -1.02739218e+00 1.38745464e+00 -0.83379476 0.79447401 161.25 9.67776115e-01 -9.57745629e-01 1.36156796e+00 -0.78018898 0.77391242 161.50 1.00339338e+00 -9.13371523e-01 1.35685143e+00 -0.73846713 0.71413162 161.75 1.07068753e+00 -8.80124094e-01 1.38599791e+00 -0.68802292 0.74526685 162.00 1.15507088e+00 -7.49919544e-01 1.37715942e+00 -0.57584157 0.72882730 162.25 1.24890190e+00 -6.69514193e-01 1.41704100e+00 -0.49209508 0.69781193 162.50 1.58549750e+00 -5.25552294e-01 1.67033157e+00 -0.32007684 0.74797325 162.75 1.74705028e+00 -3.98641183e-01 1.79195409e+00 -0.22433874 0.70637933 163.00 2.62872621e+00 -7.36932850e-02 2.62975896e+00 -0.02802650 0.66521110 163.25 2.92811017e+00 -4.49844853e-01 2.96246342e+00 -0.15243793 0.68601287 163.50 2.90659623e+00 -1.29525951e+00 3.18213746e+00 -0.41921189 0.75889037 163.75 2.87938536e+00 -1.38804105e+00 3.19648526e+00 -0.44919416 0.77700422 164.00 2.78217372e+00 -1.59509455e+00 3.20699504e+00 -0.52057586 0.80719971 164.25 2.53491785e+00 -1.83353483e+00 3.12852337e+00 -0.62620044 0.82229792 164.50 2.51113124e+00 -1.79099356e+00 3.08438617e+00 -0.61954465 0.85373797 164.75 2.61282340e+00 -1.64964571e+00 3.09001247e+00 -0.56316343 0.84632056 165.00 2.55106778e+00 -1.47346871e+00 2.94602391e+00 -0.52377781 0.85443456 165.25 2.57173103e+00 -1.34072811e+00 2.90023316e+00 -0.48056795 0.86280595 165.50 2.66421586e+00 -1.24932161e+00 2.94259250e+00 -0.43848131 0.90481178 165.75 2.55324958e+00 -1.06703121e+00 2.76724394e+00 -0.39585095 0.88503819 166.00 2.58629658e+00 -9.33769152e-01 2.74970086e+00 -0.34648028 0.91956373 166.25 2.67036085e+00 -7.65129822e-01 2.77781402e+00 -0.27905065 0.91083736 166.50 2.85269889e+00 -5.96827054e-01 2.91446281e+00 -0.20624012 0.93545150 166.75 2.94902032e+00 -4.23193300e-01 2.97923034e+00 -0.14252995 0.91194564 167.00 3.21697694e+00 -1.54824664e-01 3.22070044e+00 -0.04809027 0.89949926 167.25 3.23019769e+00 -6.64628598e-02 3.23088137e+00 -0.02057257 0.83388705 167.50 3.61900528e+00 1.19308059e-01 3.62097136e+00 0.03295515 0.77510737 167.75 4.53892317e+00 -4.89235647e-01 4.56521358e+00 -0.10737219 0.79259224 168.00 5.05215790e+00 -8.94925034e-01 5.13080796e+00 -0.17531859 0.84722292 168.25 5.15149546e+00 -1.15216805e+00 5.27876848e+00 -0.22003579 0.87884125 168.50 5.56406420e+00 -1.37434403e+00 5.73128536e+00 -0.24215656 0.92674556 168.75 5.57929331e+00 -1.68555520e+00 5.82834540e+00 -0.29339061 0.94425563 169.00 5.88391805e+00 -1.77382175e+00 6.14548088e+00 -0.29280440 0.94399267 169.25 6.66987613e+00 -2.53266497e+00 7.13453849e+00 -0.36289965 0.91652382 169.50 6.86189616e+00 -3.50165859e+00 7.70371546e+00 -0.47185743 0.90906847 169.75 6.98080939e+00 -4.09552893e+00 8.09351944e+00 -0.53057076 0.88433352 170.00 7.56077229e+00 -4.58686325e+00 8.84333603e+00 -0.54530654 0.89152901 170.25 8.40715261e+00 -7.00585025e+00 1.09435896e+01 -0.69473054 0.87558547 170.50 8.82321015e+00 -8.97641937e+00 1.25867050e+01 -0.79400539 0.87145044 170.75 3.35116158e+00 -1.35570009e+01 1.39650477e+01 -1.32846366 0.75896315 171.00 -1.95418560e+00 -1.30216087e+01 1.31674270e+01 -1.71975720 0.76919968 171.25 -6.46305080e+00 -5.94481580e+00 8.78133592e+00 -2.39793688 0.68495632 171.50 -5.56933092e+00 -3.01516865e+00 6.33314211e+00 -2.64538542 0.68661271 171.75 -3.68144475e+00 -6.47338081e-01 3.73792483e+00 -2.96753395 0.49898132 172.00 -2.13771184e+00 -3.68457363e-01 2.16923322e+00 -2.97090907 0.21184497 172.25 -1.08076301e+00 -1.91112441e+00 2.19555123e+00 -2.08547058 0.08827959 172.50 -2.66589640e+00 -3.10398717e+00 4.09166713e+00 -2.28041275 0.22493260 172.75 -2.85896232e+00 -4.64553575e+00 5.45478395e+00 -2.12247802 0.62727467 173.00 -2.07660566e+00 -4.21672559e+00 4.70032613e+00 -2.02840082 0.64958141 173.25 -1.87552858e+00 -3.16667797e+00 3.68041530e+00 -2.10551267 0.69059649 173.50 -1.38234888e+00 -2.94920756e+00 3.25710203e+00 -2.00910727 0.68106991 173.75 -5.37087026e-01 -2.25212047e+00 2.31527732e+00 -1.80490416 0.50107016 174.00 -9.18036708e-01 -1.66877161e+00 1.90462334e+00 -2.07373722 0.27163357 174.25 -3.00391729e+00 -1.87117180e+00 3.53903984e+00 -2.58449727 0.64432470 174.50 -3.10565244e+00 -2.09016920e+00 3.74351231e+00 -2.54920381 0.81354506 174.75 -2.80725345e+00 -2.21421710e+00 3.57539219e+00 -2.47375010 0.88849496 175.00 -2.44819156e+00 -2.30956604e+00 3.36567040e+00 -2.38532298 0.88434026 175.25 -2.34444027e+00 -2.13517082e+00 3.17101792e+00 -2.40287654 0.89697888 175.50 -2.28778847e+00 -1.96487152e+00 3.01574140e+00 -2.43198199 0.88744343 175.75 -2.33984422e+00 -1.81499517e+00 2.96126298e+00 -2.48185127 0.92207460 176.00 -2.29662144e+00 -1.42562969e+00 2.70312598e+00 -2.58605475 0.87702770 176.25 -2.05828643e+00 -9.01396288e-01 2.24701097e+00 -2.72881690 0.88738148 176.50 -1.77039733e+00 -6.96743970e-01 1.90256639e+00 -2.76665695 0.87406229 176.75 -1.44918048e+00 -5.63796260e-01 1.55498883e+00 -2.77056586 0.87243860 177.00 -1.17703499e+00 -5.65347181e-01 1.30576752e+00 -2.69381696 0.81503877 177.25 -1.00673431e+00 -6.38061486e-01 1.19190454e+00 -2.57669502 0.83549756 177.50 -9.49075108e-01 -7.04680309e-01 1.18208202e+00 -2.50291426 0.82404914 177.75 -8.92790651e-01 -6.35046132e-01 1.09560884e+00 -2.52331991 0.82689510 178.00 -6.56188947e-01 -5.46797573e-01 8.54149589e-01 -2.44687826 0.73230708 178.25 -5.61262648e-01 -5.42186329e-01 7.80372844e-01 -2.37348067 0.72088196 178.50 -5.93871710e-01 -4.89483014e-01 7.69595497e-01 -2.45225482 0.54683712 178.75 -6.65578885e-01 -4.49957153e-01 8.03403194e-01 -2.54712968 0.54346803 179.00 -3.89756167e-01 -8.67939702e-02 3.99303222e-01 -2.92248002 0.16721785 179.25 -5.64120858e-02 -1.44280822e-01 1.54917007e-01 -1.94350977 0.03562582 179.50 1.53942275e-01 -6.03515332e-01 6.22839450e-01 -1.32104599 0.35806804 179.75 2.31691995e-01 -8.00005169e-01 8.32880214e-01 -1.28889581 0.62023636 180.00 3.15474790e-01 -9.88868086e-01 1.03797131e+00 -1.26197701 0.74726363 180.25 3.25534508e-01 -9.81088269e-01 1.03368608e+00 -1.25041776 0.75385437 180.50 2.23795359e-01 -1.13804357e+00 1.15983945e+00 -1.37662476 0.69404168 180.75 1.46044485e-01 -1.23599065e+00 1.24458904e+00 -1.45318181 0.74607274 181.00 -3.21578581e-02 -1.43744885e+00 1.43780851e+00 -1.59316408 0.80033174 181.25 -1.79862745e-01 -1.55008581e+00 1.56048602e+00 -1.68631379 0.83442774 181.50 -2.27046826e-01 -1.31894908e+00 1.33834859e+00 -1.74126779 0.78886408 181.75 -1.59510847e-01 -1.27398940e+00 1.28393641e+00 -1.69535394 0.78711223 182.00 -1.61085534e-01 -1.61970674e+00 1.62769729e+00 -1.66992388 0.82378499 182.25 -2.89365000e-01 -1.70712860e+00 1.73147918e+00 -1.73870430 0.86319846 182.50 -6.21536407e-01 -1.56728481e+00 1.68602764e+00 -1.94834136 0.86435251 182.75 -7.83900022e-01 -1.49083298e+00 1.68436404e+00 -2.05488080 0.85388395 183.00 -1.01876355e+00 -1.47933147e+00 1.79619063e+00 -2.17387421 0.88260407 183.25 -1.10078862e+00 -1.37307714e+00 1.75985125e+00 -2.24656975 0.85577607 183.50 -1.22560810e+00 -1.13263625e+00 1.66882597e+00 -2.39559827 0.78483821 183.75 -1.23034226e+00 -1.04862162e+00 1.61658571e+00 -2.43576441 0.79491503 184.00 -1.34877273e+00 -8.49850027e-01 1.59418724e+00 -2.57934052 0.84259751 184.25 -1.34335927e+00 -7.89802948e-01 1.55833335e+00 -2.61009447 0.82298784 184.50 -1.51693611e+00 -6.18803671e-01 1.63829580e+00 -2.75426886 0.84694521 184.75 -1.47258874e+00 -2.88221702e-01 1.50052968e+00 -2.94831151 0.78020079 185.00 -1.22990424e+00 1.25130678e-01 1.23625326e+00 3.04020135 0.73707610 185.25 -8.74505462e-01 3.14381007e-01 9.29298241e-01 2.79648353 0.46548124 185.50 -7.53538530e-02 3.66633790e-01 3.74297394e-01 1.77350248 0.11236654 185.75 1.29873815e-01 -1.62354428e-01 2.07909038e-01 -0.89609192 0.03755489 186.00 -1.25689102e-01 -8.89343988e-01 8.98181763e-01 -1.71119439 0.55200307 186.25 -2.05329160e-01 -7.25059007e-01 7.53571913e-01 -1.84676028 0.46375534 186.50 -3.38601939e-01 -7.53243753e-01 8.25849517e-01 -1.99325522 0.58141489 186.75 -4.27878001e-01 -8.72129466e-01 9.71436766e-01 -2.02690613 0.64209656 187.00 -3.84182083e-01 -9.67960273e-01 1.04141393e+00 -1.94862623 0.78391505 187.25 -4.94733791e-01 -9.05008441e-01 1.03140768e+00 -2.07107322 0.76492628 187.50 -5.89359334e-01 -9.34382385e-01 1.10472389e+00 -2.13351799 0.84839746 187.75 -5.99023069e-01 -9.28378823e-01 1.10486012e+00 -2.14381494 0.83987705 188.00 -6.04239708e-01 -9.27017561e-01 1.10655645e+00 -2.14844320 0.86971023 188.25 -5.60953337e-01 -9.11883534e-01 1.07060741e+00 -2.12228763 0.83364371 188.50 -5.08096376e-01 -9.39672062e-01 1.06824413e+00 -2.06648432 0.86255969 188.75 -4.38332535e-01 -8.52700217e-01 9.58766433e-01 -2.04562250 0.79305923 189.00 -3.54989024e-01 -7.75250535e-01 8.52660894e-01 -2.00020236 0.77951559 189.25 -1.41432062e-01 -8.03486683e-01 8.15839370e-01 -1.74503433 0.63149138 189.50 -3.55437425e-03 -9.47458265e-01 9.47464932e-01 -1.57454779 0.64571089 189.75 1.77554043e-01 -9.27432061e-01 9.44275206e-01 -1.38163821 0.56843172 190.00 2.90158393e-01 -1.02253735e+00 1.06290852e+00 -1.29430150 0.61989973 190.25 2.63919296e-01 -1.05204939e+00 1.08464801e+00 -1.32500646 0.63337284 190.50 1.64066376e-01 -1.16109932e+00 1.17263353e+00 -1.43042303 0.74868866 190.75 9.75320090e-02 -1.13135588e+00 1.13555212e+00 -1.48480087 0.77612415 191.00 -2.92764265e-02 -1.06993925e+00 1.07033971e+00 -1.59815220 0.78699671 191.25 -3.32592399e-01 -9.41618492e-01 9.98630606e-01 -1.91033111 0.63572154 191.50 -6.23269521e-01 -6.93580519e-01 9.32479937e-01 -2.30285182 0.49764784 191.75 -4.95022824e-01 3.84634698e-01 6.26890299e-01 2.48103181 0.22139216 192.00 -1.31316910e-02 9.06743003e-01 9.06838086e-01 1.58527758 0.44748919 192.25 5.71488083e-01 9.14799549e-01 1.07863657e+00 1.01240270 0.56515434 192.50 8.48769568e-01 8.01711309e-01 1.16754049e+00 0.75689404 0.61719617 192.75 1.22509106e+00 7.09579760e-01 1.41575123e+00 0.52498925 0.64591337 193.00 1.37233803e+00 6.74038260e-01 1.52893402e+00 0.45655105 0.64835763 193.25 1.49676860e+00 1.56745612e-01 1.50495363e+00 0.10434235 0.72443561 193.50 1.53486776e+00 1.41643660e-01 1.54138962e+00 0.09202331 0.72651942 193.75 1.14353341e+00 1.54511228e-01 1.15392477e+00 0.13430400 0.62814495 194.00 1.16561467e+00 1.16371081e-01 1.17140931e+00 0.09950693 0.61564763 194.25 1.27939328e+00 2.06358543e-01 1.29592863e+00 0.15991677 0.76358768 194.50 1.31399847e+00 2.25088005e-01 1.33313788e+00 0.16965342 0.74969574 194.75 1.46088971e+00 1.22429671e-01 1.46601083e+00 0.08360950 0.84549827 195.00 1.38513162e+00 3.71565379e-02 1.38562990e+00 0.02681884 0.81061099 195.25 1.31486681e+00 8.09183477e-03 1.31489171e+00 0.00615403 0.84978993 195.50 1.33450554e+00 3.11447919e-02 1.33486892e+00 0.02333384 0.84373211 195.75 1.39007741e+00 6.07508786e-02 1.39140428e+00 0.04367544 0.87123049 196.00 1.34510090e+00 3.14459892e-02 1.34546842e+00 0.02337391 0.82018548 196.25 1.31757001e+00 -2.02786654e-01 1.33308408e+00 -0.15271129 0.77598640 196.50 1.26728547e+00 -4.39476200e-01 1.34132464e+00 -0.33380824 0.77138770 196.75 1.08770485e+00 -5.27531355e-01 1.20888013e+00 -0.45157167 0.81764465 197.00 8.79346740e-01 -4.58846628e-01 9.91862348e-01 -0.48093825 0.72654301 197.25 6.75834843e-01 -3.97586847e-01 7.84109708e-01 -0.53176467 0.81671358 197.50 5.57433176e-01 -2.33189521e-01 6.04242582e-01 -0.39620527 0.58869070 197.75 4.09871727e-01 4.18695638e-02 4.12004724e-01 0.10179973 0.47749641 198.00 4.53265222e-01 2.78482567e-01 5.31979230e-01 0.55093476 0.46334174 198.25 5.29017161e-01 5.34454732e-01 7.51998017e-01 0.79051116 0.64742954 198.50 8.45424766e-01 4.88562950e-01 9.76440879e-01 0.52400386 0.59028219 198.75 1.23949221e+00 6.85429406e-01 1.41638781e+00 0.50513751 0.72961278 199.00 1.22253821e+00 4.17805763e-01 1.29196027e+00 0.32930877 0.70697550 199.25 1.26407862e+00 3.31438487e-01 1.30680765e+00 0.25642548 0.80558022 199.50 1.13909141e+00 1.83122880e-01 1.15371714e+00 0.15939838 0.69536200 199.75 8.95931402e-01 9.39212052e-02 9.00840869e-01 0.10444930 0.68139948 200.00 8.49863374e-01 2.24323573e-01 8.78970318e-01 0.25806672 0.65823229 200.25 8.07927902e-01 2.68754162e-01 8.51455398e-01 0.32113202 0.63751214 200.50 6.91494554e-01 5.13855088e-01 8.61517133e-01 0.63907557 0.49973631 200.75 7.40907733e-01 6.59049135e-01 9.91609818e-01 0.72699244 0.54845754 201.00 8.41353306e-01 8.51167752e-01 1.19681324e+00 0.79119681 0.47033235 201.25 9.36319598e-01 9.68529815e-01 1.34712449e+00 0.80230614 0.50996521 201.50 1.03923254e+00 5.89945402e-01 1.19500621e+00 0.51631125 0.43617725 201.75 1.16452442e+00 6.24150810e-01 1.32124235e+00 0.49200829 0.50689727 202.00 8.54369663e-01 4.58253695e-01 9.69507076e-01 0.49231439 0.29470722 202.25 7.89213245e-01 4.31770735e-01 8.99601864e-01 0.50060636 0.29053252 202.50 1.10586015e+00 5.99132990e-01 1.25773090e+00 0.49651043 0.46684528 202.75 1.13307153e+00 7.29129674e-01 1.34739793e+00 0.57179106 0.53330166 203.00 8.68118745e-01 5.13991952e-01 1.00886961e+00 0.53457238 0.33926442 203.25 8.54420521e-01 4.25210846e-01 9.54378694e-01 0.46177379 0.32062561 203.50 8.22122073e-01 6.84053384e-01 1.06949228e+00 0.69398525 0.33142202 203.75 6.70797061e-01 7.81590483e-01 1.02997688e+00 0.86153436 0.33739176 204.00 6.68018203e-01 9.60457078e-01 1.16992569e+00 0.96308264 0.38494927 204.25 5.71125031e-01 9.13942511e-01 1.07771736e+00 1.01226707 0.30952983 204.50 3.88655726e-01 1.01286944e+00 1.08487685e+00 1.20440491 0.27749742 204.75 2.89817728e-01 1.16478938e+00 1.20030355e+00 1.32693274 0.29010548 205.00 7.83250887e-03 1.24272870e+00 1.24275339e+00 1.56449374 0.25392043 205.25 7.34704052e-02 1.00906358e+00 1.01173475e+00 1.49811410 0.15229509 205.50 -1.49835923e-01 6.53954920e-01 6.70900768e-01 1.79603134 0.06246799 205.75 6.63456166e-02 4.56334769e-01 4.61132478e-01 1.42641988 0.02728309 206.00 9.80579679e-02 2.37454553e-01 2.56904710e-01 1.17917225 0.00593204 206.25 2.09514555e-01 2.60139522e-01 3.34019340e-01 0.89277560 0.00821345 206.50 5.34996642e-01 -1.76234998e-01 5.63276292e-01 -0.31821837 0.01554736 206.75 6.27751327e-01 -2.20327148e-01 6.65293755e-01 -0.33754617 0.02719679 207.00 9.40918311e-01 -2.60834675e-01 9.76402579e-01 -0.27042234 0.05153277 207.25 7.78017930e-01 -5.17353022e-01 9.34326521e-01 -0.58682211 0.05401523 207.50 5.68301426e-01 -1.47303108e+00 1.57885626e+00 -1.20258738 0.12053595 207.75 2.86085147e-01 -1.24224383e+00 1.27476055e+00 -1.34444579 0.09548835 208.00 3.06227696e-02 -1.29427404e+00 1.29463626e+00 -1.54714055 0.12970065 208.25 2.11984192e-01 -1.10307422e+00 1.12325866e+00 -1.38093521 0.10348996 208.50 -1.82424895e-01 -1.54764523e+00 1.55835958e+00 -1.68812748 0.19586517 208.75 9.30056282e-02 -1.10465291e+00 1.10856128e+00 -1.48679999 0.11046163 209.00 3.23898730e-01 -3.20542538e-01 4.55694970e-01 -0.78019030 0.02149826 209.25 2.99442675e-03 -2.89665484e-01 2.89680961e-01 -1.56045916 0.01227383 209.50 -1.93199469e-01 -3.47953012e-01 3.97991625e-01 -2.07765815 0.02474287 209.75 1.02487236e-01 -1.45091991e-01 1.77638169e-01 -0.95581438 0.00474703 210.00 1.70678462e-01 -4.82939372e-02 1.77379372e-01 -0.27574467 0.00574270 210.25 5.16825593e-01 2.99232834e-01 5.97200957e-01 0.52482188 0.06203819 210.50 5.36629649e-01 3.78923954e-01 6.56928263e-01 0.61482034 0.08134593 210.75 5.66854563e-01 1.14193800e-01 5.78242440e-01 0.19879101 0.06615704 211.00 5.55417207e-01 8.90517063e-02 5.62510871e-01 0.15897993 0.07146513 211.25 7.50385596e-01 2.25523694e-01 7.83542902e-01 0.29195556 0.08811350 211.50 6.12344547e-01 4.53584001e-02 6.14022173e-01 0.07393830 0.05246606 211.75 8.23395042e-01 1.10152776e-01 8.30730419e-01 0.13298916 0.10305292 212.00 8.38110128e-01 8.46457486e-02 8.42373723e-01 0.10065467 0.10927802 212.25 5.86424878e-01 -5.62343642e-02 5.89114964e-01 -0.09560123 0.05073876 212.50 4.43302323e-01 -1.30065705e-01 4.61989218e-01 -0.28539247 0.03337225 212.75 7.45871381e-01 1.15174716e-01 7.54711423e-01 0.15320627 0.08463827 213.00 7.96779932e-01 3.44302863e-02 7.97523482e-01 0.04318492 0.09611771 213.25 4.44077053e-01 -1.62659179e-01 4.72929633e-01 -0.35110914 0.02918281 213.50 4.47007608e-01 -8.01421499e-02 4.54134964e-01 -0.17740114 0.02840663 213.75 5.45418408e-01 1.51371129e-01 5.66033973e-01 0.27071878 0.05059160 214.00 5.92476616e-01 -1.46398493e-02 5.92657460e-01 -0.02470455 0.06378997 214.25 8.56586772e-01 -9.01575753e-02 8.61318342e-01 -0.10486602 0.12005859 214.50 8.43671115e-01 2.53549051e-02 8.44052025e-01 0.03004402 0.11759842 214.75 8.54145129e-01 -3.44202538e-01 9.20890486e-01 -0.38307183 0.10727407 215.00 6.33205247e-01 -4.95780928e-01 8.04206201e-01 -0.66427040 0.07786812 215.25 8.58896874e-01 -6.34125227e-01 1.06762289e+00 -0.63597222 0.13291424 215.50 7.67694891e-01 -4.65109375e-01 8.97598004e-01 -0.54471123 0.09893578 215.75 5.65004145e-01 -2.35270978e-01 6.12031140e-01 -0.39456878 0.05041278 216.00 4.52506544e-01 -8.11376558e-02 4.59723277e-01 -0.17742174 0.02838854 216.25 4.97793307e-01 6.83623150e-02 5.02465504e-01 0.13647702 0.03407797 216.50 3.60407332e-01 -2.71842982e-02 3.61431087e-01 -0.07528404 0.01708725 216.75 1.95990562e-01 8.26601679e-02 2.12708730e-01 0.39911962 0.00640338 217.00 3.44979410e-01 1.49175581e-01 3.75851230e-01 0.40813761 0.01873492 217.25 4.00842901e-01 2.16179880e-01 4.55421532e-01 0.49460139 0.03101901 217.50 3.99887061e-01 -1.50777240e-01 4.27368036e-01 -0.36056633 0.02875714 217.75 5.73336479e-01 -5.22325386e-01 7.75589148e-01 -0.73887443 0.14418399 218.00 5.75014798e-01 -5.43447038e-01 7.91186894e-01 -0.75718139 0.12553337 218.25 4.33399856e-01 -7.73281782e-01 8.86453693e-01 -1.05995164 0.17968365 218.50 3.76785223e-01 -6.14671983e-01 7.20963765e-01 -1.02088309 0.16145123 218.75 3.74023499e-01 -5.97562994e-01 7.04964616e-01 -1.01153948 0.21489231 219.00 5.08118376e-01 -6.91076588e-01 8.57771027e-01 -0.93679819 0.28455135 219.25 5.57797057e-01 -7.39211709e-01 9.26051568e-01 -0.92436814 0.45998929 219.50 5.11421694e-01 -6.27869981e-01 8.09798038e-01 -0.88725557 0.35650403 219.75 5.03702791e-01 -5.21671206e-01 7.25160223e-01 -0.80292014 0.34709864 220.00 4.79738336e-01 -3.53178180e-01 5.95721157e-01 -0.63460344 0.25869894 220.25 3.72620237e-01 -3.05356163e-01 4.81755360e-01 -0.68650878 0.25748996 220.50 3.65299043e-01 -3.41286973e-01 4.99920183e-01 -0.75142801 0.25477363 220.75 4.17218643e-01 -2.67533157e-01 4.95626256e-01 -0.57018537 0.27534831 221.00 3.74777403e-01 7.38034000e-02 3.81975187e-01 0.19443801 0.11993136 221.25 4.97633046e-01 2.30638929e-01 5.48482419e-01 0.43400050 0.21914547 221.50 1.06991800e+00 2.84572197e-01 1.10711601e+00 0.25995720 0.48874354 221.75 1.38627363e+00 3.54363900e-01 1.43084882e+00 0.25026418 0.66828928 222.00 1.44026359e+00 2.32048701e-01 1.45883714e+00 0.15974267 0.68733301 222.25 1.55176328e+00 2.58998783e-01 1.57322905e+00 0.16538165 0.72597392 222.50 2.03946266e+00 -1.86492641e-01 2.04797155e+00 -0.09118845 0.72108457 222.75 2.29832525e+00 -4.28592873e-01 2.33794585e+00 -0.18436291 0.81012021 223.00 2.14054170e+00 -5.49323068e-01 2.20990375e+00 -0.25120704 0.79310050 223.25 2.00226357e+00 -7.38572297e-01 2.13413881e+00 -0.35338445 0.81994784 223.50 1.88656243e+00 -8.75700961e-01 2.07989662e+00 -0.43458168 0.85394723 223.75 1.88508311e+00 -8.83886596e-01 2.08201677e+00 -0.43844698 0.86399281 224.00 1.85599230e+00 -8.85738878e-01 2.05651180e+00 -0.44526785 0.88861377 224.25 1.94673895e+00 -8.91851685e-01 2.14130614e+00 -0.42959091 0.89951617 224.50 1.76701106e+00 -1.25891408e+00 2.16960659e+00 -0.61903554 0.86943118 224.75 1.66713737e+00 -1.41740295e+00 2.18823631e+00 -0.70461113 0.86317093 225.00 1.34772186e+00 -1.45584092e+00 1.98389188e+00 -0.82394394 0.87693250 225.25 1.22577387e+00 -1.35554994e+00 1.82757688e+00 -0.83563088 0.85370105 225.50 1.27188941e+00 -1.03266584e+00 1.63832274e+00 -0.68196396 0.83519217 225.75 1.23317729e+00 -1.02313292e+00 1.60235053e+00 -0.69257372 0.80893482 226.00 1.30134320e+00 -7.46949460e-01 1.50047580e+00 -0.52106998 0.77631765 226.25 1.33412297e+00 -6.35379774e-01 1.47769806e+00 -0.44447000 0.68158541 226.50 2.00662431e+00 -8.73284287e-01 2.18841645e+00 -0.41047890 0.68252064 226.75 1.81619340e+00 -1.32608750e+00 2.24879224e+00 -0.63067341 0.64814296 227.00 1.46139294e+00 -1.62579202e+00 2.18606245e+00 -0.83860001 0.74388351 227.25 1.70768728e+00 -1.37648020e+00 2.19337493e+00 -0.67841869 0.67435547 227.50 1.79948494e+00 -1.76763646e+00 2.52243626e+00 -0.77647006 0.66819453 227.75 1.14439167e+00 -1.67002970e+00 2.02450772e+00 -0.97003688 0.53144023 228.00 2.13392360e-01 -7.47608042e-01 7.77466452e-01 -1.29275631 0.17356286 228.25 3.40823841e-01 -8.62596938e-02 3.51570228e-01 -0.24788640 0.03812604 228.50 1.00723535e+00 2.60567199e-01 1.04039335e+00 0.25314572 0.24663741 228.75 1.65598646e+00 1.21904590e-01 1.66046737e+00 0.07348194 0.34482224 229.00 1.94954671e+00 -3.71550975e-01 1.98463661e+00 -0.18832483 0.34991800 229.25 1.43559830e+00 -1.37109751e+00 1.98515765e+00 -0.76242117 0.35838872 229.50 1.12004246e+00 -2.01927322e+00 2.30910360e+00 -1.06437016 0.56918885 229.75 1.12664267e+00 -1.51266182e+00 1.88612552e+00 -0.93062637 0.51643383 230.00 1.37872844e+00 -1.29478516e+00 1.89139121e+00 -0.75401036 0.65375993 230.25 1.37077539e+00 -8.85309568e-01 1.63180826e+00 -0.57344934 0.47736518 230.50 1.61541706e+00 -8.83450786e-01 1.84121090e+00 -0.50045014 0.48993888 230.75 1.42415580e+00 -1.25986681e+00 1.90144264e+00 -0.72426445 0.46388358 231.00 1.62820508e+00 -1.23654642e+00 2.04452900e+00 -0.64952409 0.51222772 231.25 1.79063153e+00 -1.40993638e+00 2.27909672e+00 -0.66700828 0.54838985 231.50 1.75307161e+00 -1.71169257e+00 2.45013296e+00 -0.77345592 0.59268762 231.75 1.68971314e+00 -1.47684324e+00 2.24414715e+00 -0.71827474 0.46754720 232.00 1.56317880e+00 -1.71171379e+00 2.31807939e+00 -0.83072278 0.46209972 232.25 1.43055616e+00 -1.92189439e+00 2.39586497e+00 -0.93092302 0.48663476 232.50 1.39070961e+00 -2.00035919e+00 2.43629023e+00 -0.96327892 0.48180338 232.75 8.83861003e-01 -2.30187368e+00 2.46573168e+00 -1.20418083 0.43592361 233.00 9.21631098e-01 -2.72631035e+00 2.87787630e+00 -1.24480618 0.53217466 233.25 9.11442430e-01 -2.57407591e+00 2.73067649e+00 -1.23048669 0.56761639 233.50 6.92461463e-01 -2.57422913e+00 2.66573789e+00 -1.30801902 0.60674665 233.75 4.78556203e-01 -2.44495258e+00 2.49134686e+00 -1.37750767 0.53775307 234.00 3.29499842e-01 -2.48022542e+00 2.50201684e+00 -1.43871896 0.49249133 234.25 -1.87772300e-01 -2.41924913e+00 2.42652525e+00 -1.64825697 0.40889566 234.50 -5.65539853e-01 -2.41715336e+00 2.48243141e+00 -1.80063137 0.48499266 234.75 -8.23408802e-01 -2.90135424e+00 3.01593410e+00 -1.84732671 0.62581705 235.00 -1.00702904e+00 -2.84546861e+00 3.01841003e+00 -1.91094683 0.63777331 235.25 -8.15106012e-01 -2.64444977e+00 2.76722106e+00 -1.86978888 0.63603535 235.50 -8.11080780e-01 -2.55277527e+00 2.67852825e+00 -1.87843432 0.61850825 235.75 -1.20093428e+00 -2.35484489e+00 2.64339510e+00 -2.04239956 0.71831253 236.00 -1.06435696e+00 -2.07741577e+00 2.33420479e+00 -2.04427238 0.71022801 236.25 -8.21366954e-01 -1.63654902e+00 1.83110250e+00 -2.03595448 0.68236986 236.50 -4.20141048e-01 -1.44983992e+00 1.50948809e+00 -1.85285490 0.54954705 236.75 2.61216836e-01 -1.39123257e+00 1.41554311e+00 -1.38519791 0.52744426 237.00 5.64367362e-01 -1.45203253e+00 1.55785397e+00 -1.20009167 0.45551696 237.25 1.08582725e+00 -2.12338722e+00 2.38490966e+00 -1.09809761 0.59101242 237.50 1.12885890e+00 -2.18426523e+00 2.45872670e+00 -1.09378816 0.50043192 237.75 1.29718625e+00 -2.09195581e+00 2.46149778e+00 -1.01574064 0.43693870 238.00 9.58131600e-01 -1.27052276e+00 1.59130269e+00 -0.92466113 0.15898825 238.25 4.78460505e-01 2.54119886e-01 5.41757669e-01 0.48823247 0.01021274 238.50 -6.12499419e-01 9.46332377e-01 1.12725352e+00 2.14522532 0.05469997 238.75 -2.07274414e+00 2.00737031e+00 2.88544690e+00 2.37221567 0.33178505 239.00 -1.82457300e+00 1.49015733e+00 2.35576644e+00 2.45674202 0.37772541 239.25 -1.85450003e+00 1.21692008e+00 2.21812192e+00 2.56087232 0.54691052 239.50 -1.87000440e+00 8.30183243e-01 2.04600114e+00 2.72378361 0.66870877 239.75 -1.87719638e+00 5.95211661e-01 1.96930017e+00 2.83454544 0.78276192 240.00 -1.85316007e+00 2.98450101e-01 1.87703882e+00 2.98191447 0.74283302 240.25 -1.89225667e+00 1.92748997e-01 1.90204823e+00 3.04008081 0.78856028 240.50 -1.87077800e+00 1.76468902e-01 1.87908264e+00 3.04754180 0.78443767 240.75 -2.01794074e+00 3.01271281e-01 2.04030616e+00 2.99339090 0.85107789 241.00 -2.07859457e+00 4.94471986e-01 2.13659962e+00 2.90804593 0.81868713 241.25 -2.07772118e+00 7.78932328e-01 2.21893237e+00 2.78291191 0.84466410 241.50 -1.84561087e+00 8.56231124e-01 2.03455431e+00 2.70721651 0.91325042 241.75 -1.77193527e+00 8.27185786e-01 1.95550273e+00 2.70483451 0.92257447 242.00 -1.80258626e+00 7.30343732e-01 1.94492138e+00 2.75664217 0.89802294 242.25 -1.80243557e+00 6.66697593e-01 1.92178554e+00 2.78731208 0.85903363 242.50 -1.93628185e+00 6.46760165e-01 2.04144217e+00 2.81922269 0.90221799 242.75 -2.02008584e+00 7.56680176e-01 2.15715361e+00 2.78319181 0.92134012 243.00 -2.19651468e+00 1.33990239e+00 2.57293901e+00 2.59384320 0.90199403 243.25 -2.21853115e+00 1.64142529e+00 2.75973866e+00 2.50460614 0.89079733 243.50 -1.86287844e+00 2.18734893e+00 2.87311876e+00 2.27625354 0.85441613 243.75 -1.98402921e+00 2.22852426e+00 2.98373797e+00 2.29821990 0.80433481 244.00 -1.69301253e+00 2.96467815e+00 3.41403105e+00 2.08966542 0.62925307 244.25 -1.09585147e+00 3.96670038e+00 4.11528886e+00 1.84033611 0.75791125 244.50 5.36206593e-02 5.25520352e+00 5.25547707e+00 1.56059333 0.80026526 244.75 1.25003017e+00 5.63274936e+00 5.76978689e+00 1.35241363 0.82641226 245.00 3.52121059e+00 5.17904538e+00 6.26270189e+00 0.97369101 0.83981865 245.25 4.37407072e+00 4.27785028e+00 6.11821033e+00 0.77427734 0.81385986 245.50 4.97811903e+00 1.00624434e+00 5.07879875e+00 0.19944610 0.76634975 245.75 4.37687801e+00 -4.60753905e-02 4.37712052e+00 -0.01052661 0.79614130 246.00 3.67559045e+00 -6.02999408e-01 3.72472461e+00 -0.16260664 0.82580314 246.25 3.29633700e+00 -7.96179051e-01 3.39112646e+00 -0.23699538 0.80896831 246.50 2.76378758e+00 -8.95190874e-01 2.90514862e+00 -0.31323669 0.71257504 246.75 2.29362696e+00 -9.87632381e-01 2.49722694e+00 -0.40660307 0.65212222 247.00 1.80237677e+00 -1.43017185e+00 2.30085930e+00 -0.67076014 0.68421355 247.25 1.55117926e+00 -1.24366371e+00 1.98817920e+00 -0.67580936 0.54320011 247.50 1.41647804e+00 -7.94693982e-01 1.62417627e+00 -0.51127601 0.53513652 247.75 1.43968839e+00 -9.29719437e-01 1.71379138e+00 -0.57340165 0.54134031 248.00 1.09993899e+00 -1.04796687e+00 1.51924335e+00 -0.76120624 0.48782276 248.25 1.07913199e+00 -9.16812760e-01 1.41600547e+00 -0.70425223 0.41949217 248.50 1.24713705e+00 -7.43637635e-01 1.45201507e+00 -0.53767661 0.42076295 248.75 1.28950892e+00 -6.76919695e-01 1.45638372e+00 -0.48340293 0.34617703 249.00 1.07041733e+00 -6.22395456e-01 1.23821216e+00 -0.52666902 0.28421018 249.25 9.42915490e-01 -7.73531027e-01 1.21960644e+00 -0.68703343 0.24833912 249.50 7.65829115e-01 -9.57235518e-01 1.22588501e+00 -0.89602946 0.21599972 249.75 1.19740059e+00 -8.09655023e-01 1.44544437e+00 -0.59455798 0.09682911 250.00 1.73766405e+00 -5.97246726e-01 1.83743844e+00 -0.33105733 0.13132788 250.25 1.01309696e+00 -4.04220927e-01 1.09076121e+00 -0.37963996 0.12742050 250.50 9.90630903e-01 -1.01200031e+00 1.41615473e+00 -0.79606842 0.32421674 250.75 7.39420813e-01 -7.80853827e-01 1.07539567e+00 -0.81264506 0.20194253 251.00 7.92443326e-01 -8.79266072e-01 1.18367025e+00 -0.83728805 0.28736914 251.25 8.18547221e-01 -1.11385161e+00 1.38227528e+00 -0.93704248 0.39984459 251.50 8.14156933e-01 -1.18330535e+00 1.43633668e+00 -0.96814496 0.49223897 251.75 1.06096635e+00 -1.03277895e+00 1.48063566e+00 -0.77193631 0.47535047 252.00 1.31060579e+00 -8.84193629e-01 1.58097625e+00 -0.59350574 0.53549140 252.25 1.54591883e+00 -8.69950021e-01 1.77388784e+00 -0.51257159 0.55702377 252.50 1.85554320e+00 -1.28908927e+00 2.25937861e+00 -0.60717583 0.66605135 252.75 1.92551497e+00 -1.98247984e+00 2.76366319e+00 -0.79997363 0.73114488 253.00 1.92418185e+00 -2.52553779e+00 3.17503022e+00 -0.91972898 0.79357002 253.25 1.42632930e+00 -3.21706614e+00 3.51908082e+00 -1.15347511 0.73476699 253.50 1.17716301e+00 -3.58489770e+00 3.77322200e+00 -1.25352188 0.78037288 253.75 3.21081953e-01 -3.08942954e+00 3.10606963e+00 -1.46723891 0.73640783 254.00 -1.45553062e-05 -2.96947964e+00 2.96947964e+00 -1.57080123 0.74755811 254.25 -8.13111124e-01 -3.03788344e+00 3.14481883e+00 -1.83232319 0.81691945 254.50 -8.88486552e-01 -2.92723073e+00 3.05909923e+00 -1.86548356 0.85866415 254.75 -6.68348972e-01 -2.72766607e+00 2.80835406e+00 -1.81108808 0.80609717 255.00 -6.44837940e-01 -2.72251433e+00 2.79783849e+00 -1.80336437 0.82801579 255.25 -8.11523302e-01 -2.89795077e+00 3.00943329e+00 -1.84383610 0.83778918 255.50 -9.67462475e-01 -2.88329545e+00 3.04127873e+00 -1.89453204 0.82009406 255.75 -1.55357139e+00 -3.01902802e+00 3.39530768e+00 -2.04605025 0.83017395 256.00 -1.77191945e+00 -2.91744214e+00 3.41338061e+00 -2.11660546 0.83476441 256.25 -2.40872081e+00 -2.97488092e+00 3.82777383e+00 -2.25141580 0.76204552 256.50 -3.03017551e+00 -2.72752019e+00 4.07692654e+00 -2.40871151 0.76541916 256.75 -4.39082837e+00 -2.50933196e+00 5.05728392e+00 -2.62239724 0.83713945 257.00 -4.69368612e+00 -1.77011787e+00 5.01637385e+00 -2.78095813 0.78976442 257.25 -4.92297068e+00 -1.02969330e-03 4.92297079e+00 -3.14138349 0.75958215 257.50 -4.03503848e+00 1.09066386e+00 4.17984249e+00 2.87760285 0.66443324 257.75 -2.50079359e+00 2.24339192e+00 3.35957972e+00 2.41039759 0.71426642 258.00 -1.63548548e+00 1.85280030e+00 2.47137243e+00 2.29397644 0.64005046 258.25 -1.19184959e+00 1.68875274e+00 2.06697636e+00 2.18537582 0.69403533 258.50 -9.01497794e-01 1.56465307e+00 1.80577892e+00 2.09350543 0.59114132 258.75 -5.18942668e-01 1.24636634e+00 1.35008538e+00 1.96532993 0.56403965 259.00 -2.52827867e-01 8.90147044e-01 9.25355980e-01 1.84753750 0.35408649 259.25 -1.02294645e-01 7.27773313e-01 7.34927336e-01 1.71043988 0.37127615 259.50 -1.06038599e-02 6.10210549e-01 6.10302676e-01 1.58817196 0.23634554 259.75 2.40123169e-01 6.85398253e-01 7.26243693e-01 1.23381768 0.43357118 260.00 3.09586114e-01 6.11614301e-01 6.85503913e-01 1.10221801 0.32998670 260.25 4.25549110e-01 4.30188718e-01 6.05106915e-01 0.79081987 0.30071210 260.50 5.15647512e-01 4.34705622e-01 6.74434085e-01 0.70043288 0.26648263 260.75 6.73443598e-01 3.34933979e-01 7.52134994e-01 0.46152156 0.36036207 261.00 8.33412523e-01 2.66002109e-01 8.74833445e-01 0.30895186 0.34571410 261.25 1.18390284e+00 2.46950998e-01 1.20938444e+00 0.20564194 0.50498977 261.50 1.17285734e+00 -1.57561952e-02 1.17296317e+00 -0.01343322 0.40318030 261.75 1.19564796e+00 -7.18640235e-01 1.39499743e+00 -0.54118876 0.50427998 262.00 7.49731964e-01 -1.28235248e+00 1.48543795e+00 -1.04173739 0.55525264 262.25 3.34353203e-01 -1.45427944e+00 1.49222007e+00 -1.34481354 0.66438911 262.50 -1.81234031e-02 -1.18858875e+00 1.18872691e+00 -1.58604298 0.49902228 262.75 -2.34325324e-01 -1.08246781e+00 1.10754003e+00 -1.78398022 0.56075807 263.00 -2.26541209e-01 -9.53504283e-01 9.80046599e-01 -1.80405946 0.47396866 263.25 -3.24488618e-01 -8.16459605e-01 8.78577914e-01 -1.94908848 0.50735210 263.50 -1.32859214e-01 -7.99929655e-01 8.10887800e-01 -1.73538253 0.46651998 263.75 -6.24508886e-02 -7.29144780e-01 7.31814337e-01 -1.65623731 0.46015097 264.00 -2.13831605e-01 -7.81726325e-01 8.10444324e-01 -1.83780252 0.50499776 264.25 -2.22543489e-01 -7.65963640e-01 7.97637701e-01 -1.85355228 0.58456940 264.50 -2.00096173e-01 -7.89750675e-01 8.14705227e-01 -1.81894071 0.58555595 264.75 -1.65408310e-01 -7.52022734e-01 7.69998767e-01 -1.78730009 0.52550005 265.00 -1.46543095e-01 -6.54354716e-01 6.70563176e-01 -1.79111166 0.41703124 265.25 -2.18363086e-01 -6.75822348e-01 7.10224108e-01 -1.88331533 0.47503729 265.50 -2.18612709e-01 -7.83523036e-01 8.13449362e-01 -1.84288907 0.51377884 265.75 -2.50050637e-01 -7.85934277e-01 8.24753302e-01 -1.87882674 0.51287748 266.00 -2.00800215e-01 -7.01903826e-01 7.30061441e-01 -1.84943350 0.48531828 266.25 -2.12415148e-01 -7.01479807e-01 7.32935273e-01 -1.86482917 0.47087109 266.50 -3.39712487e-01 -7.82373820e-01 8.52943942e-01 -1.98043979 0.53218083 266.75 -2.55074256e-01 -7.81482072e-01 8.22056631e-01 -1.88629223 0.50045097 267.00 -1.66822076e-01 -7.94053476e-01 8.11388025e-01 -1.77787397 0.53720354 267.25 -2.12120909e-01 -7.33751262e-01 7.63797221e-01 -1.85221509 0.48547606 267.50 -4.55319096e-01 -6.38664010e-01 7.84351450e-01 -2.19014376 0.46116528 267.75 -3.50963834e-01 -5.72730982e-01 6.71711538e-01 -2.12056722 0.36059830 268.00 -3.25427528e-01 -4.93166142e-01 5.90860322e-01 -2.15408158 0.37531407 268.25 -2.19120318e-01 -4.73291362e-01 5.21553858e-01 -2.00438468 0.31960091 268.50 -2.16995409e-02 -3.89862834e-01 3.90466259e-01 -1.62639838 0.31030449 268.75 3.94696050e-02 -5.83293572e-01 5.84627437e-01 -1.50323253 0.50134985 269.00 2.06173399e-02 -7.23991096e-01 7.24284600e-01 -1.54232668 0.70018111 269.25 6.17589137e-02 -7.53600714e-01 7.56127105e-01 -1.48902728 0.62001994 269.50 1.21548300e-01 -7.89425390e-01 7.98728011e-01 -1.41802543 0.68508669 269.75 5.28949450e-02 -9.18758936e-01 9.20280315e-01 -1.51328764 0.66169864 270.00 -1.98559197e-03 -1.11413524e+00 1.11413701e+00 -1.57257851 0.67524064 270.25 7.37698546e-02 -1.03309515e+00 1.03572563e+00 -1.49951068 0.57803106 270.50 -2.14472076e-02 -1.05822994e+00 1.05844725e+00 -1.59106061 0.61382996 270.75 -2.22394660e-01 -1.19358303e+00 1.21412513e+00 -1.75500919 0.63886121 271.00 -3.01048456e-01 -1.35386121e+00 1.38692839e+00 -1.78959929 0.73794589 271.25 -4.77445218e-01 -1.49727677e+00 1.57155709e+00 -1.87947910 0.71345340 271.50 -9.55309142e-01 -1.79627529e+00 2.03450743e+00 -2.05958080 0.78155347 271.75 -1.42934128e+00 -1.62142614e+00 2.16149004e+00 -2.29331470 0.68297499 272.00 -2.08624996e+00 -1.49266622e+00 2.56524684e+00 -2.52055404 0.71212355 272.25 -2.48540967e+00 -6.61370005e-01 2.57190037e+00 -2.88151845 0.61943048 272.50 -2.80008768e+00 1.95961279e-01 2.80693638e+00 3.07172259 0.67758771 272.75 -2.55395615e+00 1.06715056e+00 2.76794190e+00 2.74580035 0.62782912 273.00 -1.89427788e+00 1.57309108e+00 2.46229654e+00 2.44856218 0.69949201 273.25 -8.72939149e-01 1.76171178e+00 1.96612593e+00 2.03084245 0.62538028 273.50 -8.20985752e-02 1.72480918e+00 1.72676196e+00 1.61835907 0.61852097 273.75 3.91052222e-01 1.10227371e+00 1.16958504e+00 1.22987955 0.52019263 274.00 4.53603301e-01 9.11407676e-01 1.01804710e+00 1.10899419 0.54676731 274.25 5.64524157e-01 5.80789113e-01 8.09940441e-01 0.79959852 0.43286291 274.50 6.19022017e-01 3.71719244e-01 7.22055021e-01 0.54078294 0.44184948 274.75 5.48389195e-01 1.86608878e-01 5.79269870e-01 0.32799438 0.34516422 275.00 5.41176982e-01 1.12516761e-01 5.52749986e-01 0.20499079 0.37546916 275.25 6.52572605e-01 -4.81199576e-02 6.54344355e-01 -0.07360564 0.43614985 275.50 6.37436125e-01 -1.20801802e-01 6.48781850e-01 -0.18729092 0.41078983 275.75 7.00696283e-01 -2.13300388e-01 7.32442719e-01 -0.29549961 0.43273861 276.00 6.91103374e-01 -2.55272074e-01 7.36741274e-01 -0.35382467 0.41272522 276.25 6.15755331e-01 -4.66021229e-01 7.72224328e-01 -0.64785709 0.40310285 276.50 6.04550634e-01 -5.57446853e-01 8.22331115e-01 -0.74488344 0.39878629 276.75 7.11696780e-01 -7.67987282e-01 1.04705147e+00 -0.82342207 0.48870337 277.00 7.18503369e-01 -8.98585673e-01 1.15052306e+00 -0.89630323 0.52029537 277.25 7.64277647e-01 -9.53792776e-01 1.22222788e+00 -0.89526097 0.45029461 277.50 8.06759905e-01 -9.76315357e-01 1.26651223e+00 -0.88020467 0.38090828 277.75 3.77120335e-01 -1.35285500e+00 1.40443454e+00 -1.29893889 0.31808664 278.00 1.36783396e-01 -1.45808714e+00 1.46448892e+00 -1.47725990 0.30370813 278.25 -5.55619528e-01 -1.16576514e+00 1.29140289e+00 -2.01556040 0.20130037 278.50 -6.20669988e-01 -9.25323492e-01 1.11420590e+00 -2.16162743 0.17100603 278.75 -8.14486723e-01 -7.30634324e-01 1.09417327e+00 -2.41041045 0.20770118 279.00 -6.72326933e-01 -5.70380386e-01 8.81678678e-01 -2.43804705 0.16100632 279.25 -9.37407457e-01 -4.65387395e-01 1.04657449e+00 -2.68077927 0.32028890 279.50 -8.36231704e-01 -5.37757612e-01 9.94216632e-01 -2.57010281 0.29691459 279.75 -7.88789907e-01 -3.45364638e-01 8.61084346e-01 -2.72889595 0.32489068 280.00 -6.55706993e-01 -2.78651575e-01 7.12459375e-01 -2.73975288 0.25011967 280.25 -6.26268595e-01 -3.37540917e-01 7.11439543e-01 -2.64725604 0.39437879 280.50 -6.96405018e-01 -4.59836612e-01 8.34523612e-01 -2.55801032 0.47640794 280.75 -8.70844119e-01 -5.36019218e-01 1.02258793e+00 -2.58984177 0.68362678 281.00 -8.32055046e-01 -3.84632292e-01 9.16655660e-01 -2.70858375 0.58497602 281.25 -7.61573491e-01 -2.21281464e-01 7.93069775e-01 -2.85882036 0.63105899 281.50 -6.96477123e-01 -1.69654967e-01 7.16842514e-01 -2.90265583 0.46425529 281.75 -6.71650959e-01 -1.28253214e-01 6.83786441e-01 -2.95291186 0.49946200 282.00 -5.30463020e-01 -1.31633565e-01 5.46551381e-01 -2.89835740 0.37620541 282.25 -5.04078105e-01 -1.10214935e-01 5.15986500e-01 -2.92633369 0.43426930 282.50 -5.23269832e-01 -1.61302722e-01 5.47567242e-01 -2.84257597 0.47355402 282.75 -5.18651362e-01 -1.40904488e-01 5.37450751e-01 -2.87632051 0.55576150 283.00 -4.72811959e-01 -1.96942200e-01 5.12188811e-01 -2.74691468 0.46589970 283.25 -4.19600619e-01 -2.30861676e-01 4.78917313e-01 -2.63860063 0.47134907 283.50 -3.39658864e-01 -2.00549868e-01 3.94446946e-01 -2.60822854 0.37160894 283.75 -3.34268991e-01 -2.00581746e-01 3.89831752e-01 -2.60112839 0.37186950 284.00 -3.80148078e-01 -2.39117374e-01 4.49098742e-01 -2.58011413 0.37756580 284.25 -4.07599469e-01 -2.22232546e-01 4.64246305e-01 -2.64242451 0.47423105 284.50 -4.28862153e-01 -2.25057361e-01 4.84327949e-01 -2.65831981 0.46671676 284.75 -5.12945922e-01 -2.41415317e-01 5.66916991e-01 -2.70170378 0.57801153 285.00 -5.13656414e-01 -2.32191273e-01 5.63698234e-01 -2.71704675 0.52143540 285.25 -4.94359616e-01 -2.22740219e-01 5.42221943e-01 -2.71827052 0.50036027 285.50 -4.72209974e-01 -2.20102174e-01 5.20986782e-01 -2.70542204 0.58748858 285.75 -4.72274617e-01 -1.85331564e-01 5.07337267e-01 -2.76763493 0.63765608 286.00 -4.30835236e-01 -1.65364144e-01 4.61480553e-01 -2.77510994 0.64728413 286.25 -4.27890515e-01 -1.59833740e-01 4.56768122e-01 -2.78410359 0.65410902 286.50 -4.43045394e-01 -1.04189179e-01 4.55131416e-01 -2.91062346 0.64782652 286.75 -4.24945144e-01 -8.41964227e-02 4.33205971e-01 -2.94599119 0.60724221 287.00 -3.76213475e-01 -6.86495109e-02 3.82425593e-01 -2.96110354 0.61546119 287.25 -3.55730102e-01 -8.63502521e-02 3.66060475e-01 -2.90345765 0.61194354 287.50 -3.32663704e-01 -1.45159528e-01 3.62955133e-01 -2.73014352 0.69062677 287.75 -3.11235716e-01 -1.47165801e-01 3.44275245e-01 -2.69990526 0.61859041 288.00 -3.04479960e-01 -1.08879125e-01 3.23361577e-01 -2.79817181 0.62299588 288.25 -3.11673099e-01 -1.07092670e-01 3.29558737e-01 -2.81062559 0.59834894 288.50 -2.98198236e-01 -2.03732415e-01 3.61149671e-01 -2.54222334 0.62833651 288.75 -3.00985529e-01 -2.15628047e-01 3.70253620e-01 -2.51994015 0.59126547 289.00 -3.64338977e-01 -1.77654763e-01 4.05344428e-01 -2.68790734 0.65014034 289.25 -3.34873707e-01 -1.78104455e-01 3.79290913e-01 -2.65278652 0.53847136 289.50 -3.07245056e-01 -1.82371784e-01 3.57293985e-01 -2.60591370 0.57304317 289.75 -2.91645727e-01 -1.82564092e-01 3.44073942e-01 -2.58228967 0.58259146 290.00 -2.70022660e-01 -1.88713315e-01 3.29431255e-01 -2.53161907 0.63159843 290.25 -2.37554573e-01 -2.09287125e-01 3.16596393e-01 -2.41937085 0.51616876 290.50 -2.33433341e-01 -2.24246364e-01 3.23693615e-01 -2.37626474 0.59949229 290.75 -2.36746871e-01 -2.51282888e-01 3.45242192e-01 -2.32641819 0.49633110 291.00 -2.12126532e-01 -3.13382970e-01 3.78426415e-01 -2.16584487 0.57100374 291.25 -2.38869655e-01 -3.29403030e-01 4.06896876e-01 -2.19820890 0.53565054 291.50 -2.43261393e-01 -3.28743561e-01 4.08960186e-01 -2.20784928 0.60678704 291.75 -2.68662177e-01 -3.02367164e-01 4.04481480e-01 -2.29723793 0.60962186 292.00 -3.28755289e-01 -3.19512780e-01 4.58441334e-01 -2.37045076 0.74600144 292.25 -3.43932887e-01 -2.89890838e-01 4.49807213e-01 -2.44125230 0.63668909 292.50 -2.94596438e-01 -2.48587350e-01 3.85464307e-01 -2.44069541 0.57820732 292.75 -2.56195618e-01 -2.35633730e-01 3.48079659e-01 -2.39797711 0.43514578 293.00 -2.35793949e-01 -2.76208164e-01 3.63166265e-01 -2.27742412 0.55379207 293.25 -2.32095970e-01 -3.08717683e-01 3.86231986e-01 -2.21545261 0.49017623 293.50 -2.14982494e-01 -3.34360932e-01 3.97510636e-01 -2.14221037 0.53543893 293.75 -2.64157405e-01 -2.79911639e-01 3.84876162e-01 -2.32724627 0.44090181 294.00 -2.92625914e-01 -2.83913767e-01 4.07721661e-01 -2.37130444 0.45551792 294.25 -2.68928697e-01 -3.27562411e-01 4.23815735e-01 -2.25821155 0.42839907 294.50 -2.05997764e-01 -3.55564565e-01 4.10927291e-01 -2.09589662 0.45494782 294.75 -2.28815208e-01 -4.12989395e-01 4.72140487e-01 -2.07674072 0.48376257 295.00 -2.36557180e-01 -4.87164243e-01 5.41560984e-01 -2.02284148 0.59026855 295.25 -2.43436970e-01 -4.81182471e-01 5.39257016e-01 -2.03916397 0.45495162 295.50 -2.60833696e-01 -5.25349005e-01 5.86537121e-01 -2.03163683 0.48617720 295.75 -2.09385917e-01 -4.80789960e-01 5.24405805e-01 -1.98153015 0.34883815 296.00 -2.48386685e-01 -4.91256598e-01 5.50480690e-01 -2.03892581 0.36727220 296.25 -4.43577898e-01 -5.27733201e-01 6.89393707e-01 -2.26976938 0.36838056 296.50 -4.65502765e-01 -5.13111696e-01 6.92803317e-01 -2.30758349 0.42189866 296.75 -4.91354654e-01 -5.67580202e-01 7.50717445e-01 -2.28433521 0.58650702 297.00 -4.88339986e-01 -6.28943464e-01 7.96269943e-01 -2.23100851 0.55568233 297.25 -5.64378978e-01 -6.53705524e-01 8.63628706e-01 -2.28299191 0.55774236 297.50 -6.23521427e-01 -6.64483954e-01 9.11217809e-01 -2.32440213 0.56162532 297.75 -6.08513715e-01 -5.76892583e-01 8.38507003e-01 -2.38286352 0.60587559 298.00 -5.77179830e-01 -5.05589193e-01 7.67305016e-01 -2.42221650 0.55564057 298.25 -6.36961229e-01 -3.72074265e-01 7.37671245e-01 -2.61291686 0.51694663 298.50 -6.26145672e-01 -3.82441210e-01 7.33702720e-01 -2.59327976 0.52672648 298.75 -6.35149132e-01 -4.88132687e-01 8.01054268e-01 -2.48633593 0.58904207 299.00 -6.14011939e-01 -5.07297771e-01 7.96468260e-01 -2.45107794 0.45148689 299.25 -6.80751286e-01 -2.81575840e-01 7.36686681e-01 -2.74939593 0.33841017 299.50 -8.40455688e-01 -3.04794999e-01 8.94016642e-01 -2.79368916 0.39990074 299.75 -1.01674357e+00 -5.86266786e-01 1.17365934e+00 -2.61854758 0.60662152 300.00 -1.05350893e+00 -6.29811187e-01 1.22741322e+00 -2.60277590 0.58113936 300.25 -1.20982447e+00 -4.10549976e-01 1.27758622e+00 -2.81443984 0.49284962 300.50 -1.06061336e+00 -2.31280199e-01 1.08553730e+00 -2.92689097 0.43798993 300.75 -8.64913069e-01 -2.18863922e-01 8.92174890e-01 -2.89374800 0.45320293 301.00 -9.53489490e-01 -1.56153775e-01 9.66191601e-01 -2.97926285 0.50792077 301.25 -9.21356265e-01 -9.63649167e-02 9.26381975e-01 -3.03738126 0.54982464 301.50 -8.48118109e-01 -1.80622165e-01 8.67138221e-01 -2.93175936 0.42855665 301.75 -7.91933930e-01 -2.41542799e-01 8.27950647e-01 -2.84555163 0.32226470 302.00 -1.00351587e+00 -1.60534019e-01 1.01627519e+00 -2.98296510 0.27687168 302.25 -1.33592549e+00 -1.60522816e-01 1.34553502e+00 -3.02200747 0.45142061 302.50 -1.02110525e+00 -5.95353019e-03 1.02112261e+00 -3.13576224 0.30315358 302.75 -8.75581015e-01 2.40753051e-01 9.08077170e-01 2.87326013 0.24472910 303.00 -1.22270375e+00 1.78116813e-01 1.23560919e+00 2.99693564 0.25269588 303.25 -9.81309966e-01 1.16468381e-01 9.88197416e-01 3.02345865 0.21319818 303.50 -7.55254656e-01 2.04259783e-01 7.82388430e-01 2.87746001 0.16626294 303.75 -8.55063622e-01 3.48540667e-01 9.23371212e-01 2.75453499 0.26191200 304.00 -8.44747320e-01 3.26831585e-01 9.05768690e-01 2.77243133 0.26043293 304.25 -7.82278544e-01 2.63733017e-01 8.25539112e-01 2.81642504 0.26837881 304.50 -8.42956031e-01 2.94160949e-01 8.92807669e-01 2.80584145 0.22731620 304.75 -8.96066509e-01 5.30357320e-01 1.04125601e+00 2.60717053 0.31526971 305.00 -8.14967931e-01 4.64580018e-01 9.38087055e-01 2.62347940 0.22048016 305.25 -7.50974190e-01 4.61120586e-01 8.81245953e-01 2.59092089 0.21906369 305.50 -5.35180538e-01 4.12161404e-01 6.75496285e-01 2.48532903 0.07338183 305.75 -2.75810209e-01 3.94048174e-01 4.80983612e-01 2.18148224 0.03266517 306.00 -5.30321382e-01 2.94995653e-01 6.06846936e-01 2.63395733 0.05691203 306.25 -2.91671033e-01 -2.20318673e-02 2.92501957e-01 -3.06619913 0.01813530 306.50 -1.23333673e-01 4.80875242e-02 1.32376753e-01 2.76982531 0.00460041 306.75 -2.40044467e-01 1.69536524e-01 2.93877490e-01 2.52667014 0.02819805 307.00 -2.16211174e-01 2.77519356e-01 3.51801456e-01 2.23265349 0.06074002 307.25 -3.45488767e-01 3.93510973e-01 5.23653868e-01 2.29130302 0.10782894 307.50 -4.79104704e-01 4.85589206e-01 6.82157016e-01 2.34947277 0.17076789 307.75 -3.03268117e-01 4.56543380e-01 5.48090694e-01 2.15713793 0.13253556 308.00 -2.97379394e-01 4.74137079e-01 5.59678902e-01 2.13097704 0.18217258 308.25 -2.63087117e-01 5.78117370e-01 6.35164958e-01 1.99786311 0.23780155 308.50 -1.98315296e-01 9.13030095e-01 9.34319491e-01 1.78467973 0.40486101 308.75 -1.25843824e-01 1.02487612e+00 1.03257335e+00 1.69297405 0.41630864 309.00 -1.01892025e-01 9.96104048e-01 1.00130178e+00 1.67273233 0.35392952 309.25 -7.24934481e-02 8.64898437e-01 8.67931222e-01 1.65441816 0.26510253 309.50 3.56748996e-01 7.60810146e-01 8.40298712e-01 1.13233128 0.37332867 309.75 4.08264056e-01 7.41737173e-01 8.46672058e-01 1.06763374 0.37740343 310.00 4.59340959e-01 8.46608816e-01 9.63192921e-01 1.07367869 0.43311138 310.25 3.24545229e-01 8.58235162e-01 9.17549562e-01 1.20926320 0.33397320 310.50 4.24971205e-01 7.63764019e-01 8.74034325e-01 1.06303987 0.38278183 310.75 4.86672090e-01 8.76191652e-01 1.00227817e+00 1.06378596 0.40624558 311.00 6.31574442e-01 8.89916872e-01 1.09125538e+00 0.95358959 0.48554866 311.25 8.09429232e-01 8.29427603e-01 1.15893306e+00 0.79760019 0.44739143 311.50 1.06364833e+00 8.55749372e-01 1.36515741e+00 0.67750411 0.55140044 311.75 1.37735410e+00 8.82514990e-01 1.63582915e+00 0.56983239 0.56187807 312.00 1.66138409e+00 1.07489674e+00 1.97878753e+00 0.57425540 0.63927620 312.25 1.87534868e+00 8.59190771e-01 2.06279942e+00 0.42961066 0.50592445 312.50 2.45262481e+00 9.37404224e-01 2.62566090e+00 0.36507193 0.53535325 312.75 2.54070678e+00 4.59442492e-01 2.58191370e+00 0.17889925 0.41704901 313.00 2.86351382e+00 -1.69617020e-01 2.86853295e+00 -0.05916474 0.42167613 313.25 2.21487512e+00 -4.43114789e-01 2.25876571e+00 -0.19745623 0.23928774 313.50 1.71432606e+00 -1.07599646e+00 2.02402623e+00 -0.56050254 0.15631278 313.75 2.12857720e-01 -9.88792068e-01 1.01144360e+00 -1.35876167 0.02690116 314.00 -1.79722033e+00 -1.51965205e+00 2.35358094e+00 -2.43968370 0.16219199 314.25 -2.43429310e+00 -1.76715849e+00 3.00809442e+00 -2.51366651 0.53006881 314.50 -2.48093906e+00 -1.71377242e+00 3.01530671e+00 -2.53708436 0.71274775 314.75 -1.80545548e+00 -1.61920859e+00 2.42518163e+00 -2.41052496 0.64824721 315.00 -1.65058666e+00 -1.57401829e+00 2.28078274e+00 -2.37993507 0.71526098 315.25 -1.82279071e+00 -1.39307696e+00 2.29417292e+00 -2.48903058 0.69855839 315.50 -1.77015103e+00 -1.19057721e+00 2.13328591e+00 -2.54950385 0.71030966 315.75 -1.72187846e+00 -1.00294046e+00 1.99267534e+00 -2.61416350 0.73434095 316.00 -1.69045412e+00 -8.56757715e-01 1.89516989e+00 -2.67250311 0.75538014 316.25 -1.44104523e+00 -7.12829483e-01 1.60771180e+00 -2.68222502 0.68467777 316.50 -1.45881944e+00 -5.89130508e-01 1.57328602e+00 -2.75777981 0.74707803 316.75 -1.41496996e+00 -4.42315786e-01 1.48249224e+00 -2.83861915 0.77402807 317.00 -1.33125188e+00 -4.37259008e-01 1.40122340e+00 -2.82423719 0.74069839 317.25 -1.23812954e+00 -4.97540681e-01 1.33435808e+00 -2.75949363 0.69685892 317.50 -1.24020119e+00 -4.80232394e-01 1.32993313e+00 -2.77215065 0.70379870 317.75 -1.14087457e+00 -4.38599016e-01 1.22227815e+00 -2.77457070 0.64684978 318.00 -1.03893210e+00 -3.73926301e-01 1.10417426e+00 -2.79611313 0.58430939 318.25 -9.73937809e-01 -2.24252700e-01 9.99421898e-01 -2.91528341 0.50897111 318.50 -9.90472631e-01 -1.87686173e-01 1.00809828e+00 -2.95432151 0.49504633 318.75 -1.09838912e+00 -1.79407165e-01 1.11294456e+00 -2.97968576 0.57737175 319.00 -1.07953106e+00 -1.96708885e-01 1.09730657e+00 -2.96135315 0.51356368 319.25 -9.75538389e-01 -6.02937910e-02 9.77399862e-01 -3.07986551 0.46721404 319.50 -9.82725397e-01 -7.92635276e-02 9.85916788e-01 -3.06111004 0.44875650 319.75 -9.47646132e-01 7.81883051e-02 9.50866238e-01 3.05927120 0.52366706 320.00 -8.67701113e-01 6.21545174e-02 8.69924367e-01 3.07008354 0.50198678 320.25 -8.84459430e-01 5.56914447e-02 8.86211048e-01 3.07870903 0.59808486 320.50 -8.86169116e-01 3.49222633e-02 8.86856959e-01 3.10220491 0.53000538 320.75 -7.66317672e-01 1.77008421e-02 7.66522077e-01 3.11849819 0.49734390 321.00 -7.82558741e-01 -4.58437770e-02 7.83900399e-01 -3.08307763 0.40248931 321.25 -8.38380882e-01 -4.53466460e-02 8.39606349e-01 -3.08755695 0.50272605 321.50 -8.08533550e-01 3.64591020e-02 8.09355156e-01 3.09653031 0.46870663 321.75 -7.87957390e-01 4.94010137e-02 7.89504470e-01 3.07897957 0.51898698 322.00 -6.28174297e-01 1.32601119e-01 6.42017138e-01 2.93355702 0.31522286 322.25 -5.65714148e-01 5.85117785e-02 5.68732033e-01 3.03852919 0.36700883 322.50 -5.09614462e-01 1.00045646e-01 5.19341921e-01 2.94774157 0.32759734 322.75 -5.25962443e-01 1.02401234e-01 5.35838133e-01 2.94930510 0.44281256 323.00 -5.31301990e-01 3.74019410e-02 5.32616851e-01 3.07131183 0.39772622 323.25 -6.19095216e-01 -7.63277106e-02 6.23782660e-01 -3.01892256 0.52887586 323.50 -5.34515081e-01 -6.90400886e-02 5.38955384e-01 -3.01313988 0.38164880 323.75 -4.27693204e-01 -4.93898700e-02 4.30535523e-01 -3.02662224 0.36469607 324.00 -3.72754447e-01 -1.36323180e-01 3.96900349e-01 -2.79098396 0.29126213 324.25 -3.32287293e-01 -1.47644935e-01 3.63612255e-01 -2.72346459 0.35674105 324.50 -4.57820577e-01 -1.77738773e-01 4.91111751e-01 -2.77127555 0.37961455 324.75 -5.16675421e-01 -1.30977688e-01 5.33018429e-01 -2.89332174 0.50403034 325.00 -4.84364580e-01 -1.56710593e-01 5.09084724e-01 -2.82868319 0.40392807 325.25 -4.54271570e-01 -1.68261993e-01 4.84432407e-01 -2.78686133 0.42600504 325.50 -4.49484149e-01 -2.71774528e-01 5.25259359e-01 -2.59777093 0.39271425 325.75 -4.42968629e-01 -3.02639853e-01 5.36481208e-01 -2.54222539 0.42621585 326.00 -5.66847676e-01 -3.14033470e-01 6.48022614e-01 -2.63568380 0.43989045 326.25 -6.00961436e-01 -2.17331207e-01 6.39052033e-01 -2.79458671 0.47007148 326.50 -6.54372361e-01 -1.97118448e-01 6.83417054e-01 -2.84900519 0.40955619 326.75 -6.41929863e-01 -1.06050246e-01 6.50630927e-01 -2.97786614 0.43294795 327.00 -4.45025241e-01 -1.77755465e-01 4.79212344e-01 -2.76157963 0.33938826 327.25 -3.48734058e-01 -2.57944048e-01 4.33763271e-01 -2.50474314 0.32954049 327.50 -3.13851233e-01 -2.84712067e-01 4.23749404e-01 -2.40483793 0.28272963 327.75 -3.53857435e-01 -2.96833589e-01 4.61871480e-01 -2.44360700 0.28662215 328.00 -3.32140111e-01 -4.51307736e-01 5.60353215e-01 -2.20524489 0.29969857 328.25 -3.94889067e-01 -4.69368661e-01 6.13387573e-01 -2.27022935 0.31483291 328.50 -3.04907580e-01 -4.95646068e-01 5.81922380e-01 -2.12229708 0.28983430 328.75 -3.31190938e-01 -4.66108136e-01 5.71790374e-01 -2.18856466 0.30479930 329.00 -2.20437932e-01 -6.35828736e-01 6.72956955e-01 -1.90452280 0.37989622 329.25 -2.30070729e-01 -7.48156611e-01 7.82732939e-01 -1.86913492 0.43085133 329.50 -5.45806047e-01 -7.82070443e-01 9.53697236e-01 -2.18011072 0.53218757 329.75 -6.60308758e-01 -8.90997858e-01 1.10900173e+00 -2.20856999 0.54010682 330.00 -9.03261356e-01 -9.71027216e-01 1.32618812e+00 -2.32005472 0.65485483 330.25 -1.03517622e+00 -8.83258446e-01 1.36078481e+00 -2.43521799 0.63420084 330.50 -1.23704029e+00 -7.26913785e-01 1.43480742e+00 -2.61032333 0.69144102 330.75 -1.15403087e+00 -6.07726783e-01 1.30426957e+00 -2.65688261 0.57814763 331.00 -9.51521667e-01 -2.89552844e-01 9.94602600e-01 -2.84619097 0.47638431 331.25 -8.78346992e-01 -2.79716924e-01 9.21810716e-01 -2.83328879 0.46654380 331.50 -9.10207349e-01 -2.37678811e-01 9.40727716e-01 -2.88617018 0.60338991 331.75 -9.15303486e-01 -2.49612846e-01 9.48729173e-01 -2.87535624 0.58774787 332.00 -9.34088962e-01 -2.92045387e-01 9.78679057e-01 -2.83856872 0.64317059 332.25 -9.42587748e-01 -3.16168340e-01 9.94200222e-01 -2.81795998 0.59148988 332.50 -9.04754863e-01 -2.61614395e-01 9.41819226e-01 -2.86011485 0.62431753 332.75 -7.83930043e-01 -3.21909691e-01 8.47450389e-01 -2.75195130 0.49280546 333.00 -6.18556737e-01 -5.90093143e-01 8.54881486e-01 -2.37974005 0.51975996 333.25 -4.94035985e-01 -7.82826968e-01 9.25683324e-01 -2.13376455 0.45899456 333.50 -5.50715669e-01 -1.08074176e+00 1.21296764e+00 -2.04207213 0.56314308 333.75 -7.57286157e-01 -1.25011338e+00 1.46159700e+00 -2.11545059 0.44307782 334.00 -1.30959171e+00 -1.00720032e+00 1.65211469e+00 -2.48598239 0.35999507 334.25 -6.22570843e-01 -7.59006154e-01 9.81674486e-01 -2.25776033 0.12373404 334.50 -9.02824242e-02 -9.75307440e-01 9.79477166e-01 -1.66310145 0.17078180 334.75 4.04479687e-01 -1.13964256e+00 1.20929276e+00 -1.22974693 0.22780600 335.00 5.75420114e-01 -1.50882593e+00 1.61482630e+00 -1.20645321 0.37963048 335.25 3.66192495e-01 -2.13279838e+00 2.16400690e+00 -1.40075848 0.48312481 335.50 4.96921412e-01 -2.67888955e+00 2.72458806e+00 -1.38738570 0.54552502 335.75 1.58496848e+00 -2.34968987e+00 2.83428432e+00 -0.97736020 0.26052950 336.00 1.81990320e+00 -2.02261981e+00 2.72085254e+00 -0.83810542 0.15843929 336.25 7.75432464e-01 -1.11253848e+00 1.35611112e+00 -0.96209077 0.02520259 336.50 1.73849329e+00 -8.53294550e-02 1.74058612e+00 -0.04904306 0.03279971 336.75 2.72536249e+00 -3.05283133e-01 2.74240742e+00 -0.11155060 0.09150779 337.00 3.81584507e+00 5.41562462e-01 3.85408401e+00 0.14098309 0.17797292 337.25 5.02116612e+00 2.08346712e+00 5.43626200e+00 0.39331633 0.51220205 337.50 5.00990130e+00 2.30198506e+00 5.51346046e+00 0.43071534 0.65013934 337.75 4.27349159e+00 1.99636906e+00 4.71680186e+00 0.43702542 0.66592358 338.00 4.22560392e+00 1.73924586e+00 4.56954097e+00 0.39046364 0.74274534 338.25 4.21716929e+00 1.04545287e+00 4.34482319e+00 0.24300493 0.75573766 338.50 4.05412993e+00 6.26998991e-01 4.10232827e+00 0.15344119 0.75800130 338.75 3.67934971e+00 -3.63144667e-01 3.69722712e+00 -0.09837943 0.81022803 339.00 3.36057552e+00 -5.77557260e-01 3.40984460e+00 -0.17019989 0.82995109 339.25 2.84990814e+00 -6.84511908e-01 2.93096109e+00 -0.23572213 0.80836030 339.50 2.37478678e+00 -7.27192493e-01 2.48363065e+00 -0.29714774 0.75896197 339.75 2.16097948e+00 -8.36993356e-01 2.31741023e+00 -0.36952890 0.80224992 340.00 2.03340078e+00 -8.13111232e-01 2.18994717e+00 -0.38040077 0.81088474 340.25 2.00394317e+00 -9.86049947e-01 2.23340161e+00 -0.45727131 0.83174173 340.50 1.87253377e+00 -1.03646362e+00 2.14024287e+00 -0.50553299 0.82879850 340.75 1.86867107e+00 -1.02470598e+00 2.13118603e+00 -0.50158384 0.87175371 341.00 1.80106493e+00 -1.03777207e+00 2.07865479e+00 -0.52273500 0.83747383 341.25 1.92485595e+00 -1.08414755e+00 2.20917323e+00 -0.51294814 0.86877025 341.50 2.01003824e+00 -1.20336526e+00 2.34272100e+00 -0.53944672 0.86646129 341.75 2.10854493e+00 -1.32961916e+00 2.49275928e+00 -0.56260622 0.90217381 342.00 2.09357929e+00 -1.54457309e+00 2.60168797e+00 -0.63562572 0.88263006 342.25 2.06358159e+00 -1.87831901e+00 2.79042135e+00 -0.73843443 0.91650452 342.50 1.95826197e+00 -2.05359377e+00 2.83761119e+00 -0.80915621 0.88483992 342.75 1.80946204e+00 -2.40731475e+00 3.01153071e+00 -0.92623902 0.89029512 343.00 1.64863847e+00 -2.65291745e+00 3.12345639e+00 -1.01475854 0.88100356 343.25 1.50163986e+00 -2.83242292e+00 3.20586055e+00 -1.08331215 0.90901857 343.50 1.41389133e+00 -2.93181000e+00 3.25493449e+00 -1.12144210 0.88619657 343.75 1.46549165e+00 -3.09931652e+00 3.42832738e+00 -1.12910898 0.91776418 344.00 1.51818088e+00 -3.20638783e+00 3.54764656e+00 -1.12858372 0.89569373 344.25 1.52678690e+00 -3.43511302e+00 3.75913284e+00 -1.15255498 0.91367857 344.50 1.42924667e+00 -3.84210173e+00 4.09932820e+00 -1.21466185 0.92359257 344.75 1.30245574e+00 -4.18005725e+00 4.37827244e+00 -1.26874252 0.94242562 345.00 9.76825104e-01 -4.71333719e+00 4.81349507e+00 -1.36644229 0.94410086 345.25 8.44031104e-01 -4.95456212e+00 5.02594014e+00 -1.40206181 0.95781507 345.50 6.47054931e-01 -5.03537312e+00 5.07677679e+00 -1.44299482 0.94485307 345.75 4.34102645e-01 -5.32434521e+00 5.34201245e+00 -1.48944462 0.95313867 346.00 -7.69250198e-02 -5.57519248e+00 5.57572315e+00 -1.58459318 0.96451032 346.25 -4.29665921e-01 -5.72243546e+00 5.73854340e+00 -1.64574015 0.97422631 346.50 -1.03520121e+00 -5.79922465e+00 5.89089535e+00 -1.74744258 0.97242775 346.75 -1.29129950e+00 -5.74214470e+00 5.88554842e+00 -1.79199754 0.97580768 347.00 -1.13687030e+00 -5.37564881e+00 5.49454950e+00 -1.77921059 0.95733000 347.25 -1.06948213e+00 -5.24145823e+00 5.34945571e+00 -1.77207621 0.95244679 347.50 -8.23622594e-01 -5.10891128e+00 5.17487474e+00 -1.73063403 0.94595892 347.75 -5.62052396e-01 -5.17565518e+00 5.20608389e+00 -1.67896784 0.93434081 348.00 3.51257182e-01 -5.82688725e+00 5.83746492e+00 -1.51058706 0.93079020 348.25 5.91619053e-01 -5.94398288e+00 5.97335296e+00 -1.47159064 0.93764006 348.50 1.20624409e+00 -6.37184779e+00 6.48501882e+00 -1.38370200 0.91840242 348.75 1.46642093e+00 -7.13805398e+00 7.28712597e+00 -1.36817832 0.90832368 349.00 1.88623414e+00 -8.93403074e+00 9.13097938e+00 -1.36272294 0.89723710 349.25 2.09652155e+00 -9.93395863e+00 1.01527797e+01 -1.36280259 0.89358204 349.50 1.77252950e+00 -1.13000437e+01 1.14382187e+01 -1.41520378 0.89773266 349.75 1.20211378e+00 -1.17430999e+01 1.18044683e+01 -1.46878400 0.87895154 350.00 2.16311842e-01 -1.37556122e+01 1.37573129e+01 -1.55507227 0.88512198 350.25 3.05664877e-01 -1.43352803e+01 1.43385387e+01 -1.54947700 0.88181867 350.50 -3.20633829e-01 -1.49994899e+01 1.50029165e+01 -1.59216939 0.86366459 350.75 -1.29321433e-01 -1.55006466e+01 1.55011860e+01 -1.57913910 0.82982083 351.00 1.24943725e+00 -1.98420401e+01 1.98813392e+01 -1.50791016 0.83494345 351.25 9.52379597e-01 -2.09516363e+01 2.09732709e+01 -1.52537150 0.83212005 351.50 -1.31462973e+00 -2.24535662e+01 2.24920182e+01 -1.62927838 0.79321197 351.75 -4.58302747e+00 -2.14661232e+01 2.19499109e+01 -1.78113877 0.66681613 352.00 -9.41468078e+00 -2.05652085e+01 2.26177809e+01 -2.00011489 0.69749720 352.25 -1.04238477e+01 -1.51229342e+01 1.83673553e+01 -2.17428741 0.54584646 352.50 -1.44563314e+01 -1.26005863e+01 1.91770772e+01 -2.42467396 0.60324589 352.75 -1.21950061e+01 -1.14645713e+01 1.67378185e+01 -2.38705738 0.60351208 353.00 -1.29270459e+01 -9.37862574e+00 1.59708214e+01 -2.51395407 0.67661474 353.25 -8.83456447e+00 -7.65048632e+00 1.16867220e+01 -2.42789874 0.51972741 353.50 -7.16497583e+00 -6.22138800e+00 9.48907515e+00 -2.42656683 0.46420166 353.75 -4.01362478e+00 -5.52182913e+00 6.82640321e+00 -2.19932594 0.26336272 354.00 -4.59262998e-01 -8.17492560e+00 8.18781602e+00 -1.62691681 0.39291595 354.25 3.18990431e+00 -1.15159448e+01 1.19495805e+01 -1.30057268 0.45160885 354.50 5.73648041e+00 -1.83916459e+01 1.92655092e+01 -1.26845192 0.66248096 354.75 1.19090445e+00 -2.12566703e+01 2.12900043e+01 -1.51482986 0.53282407 355.00 -4.54674436e+00 -2.88514454e+01 2.92075125e+01 -1.72710239 0.60602158 355.25 -1.86474404e+01 -2.94230531e+01 3.48345100e+01 -2.13567712 0.55794681 355.50 -2.98542358e+01 -2.79021704e+01 4.08632660e+01 -2.38997988 0.55932454 355.75 -3.33680238e+01 -7.32510962e+00 3.41625855e+01 -2.92549563 0.59452126 356.00 -3.41011085e+01 -1.83167895e+00 3.41502657e+01 -3.08793104 0.75461725 356.25 -2.66097342e+01 3.93743723e+00 2.68994678e+01 2.99468881 0.83277019 356.50 -2.21614881e+01 5.62849025e+00 2.28650707e+01 2.89287521 0.86856361 356.75 -1.55230378e+01 5.18319857e+00 1.63655202e+01 2.81932893 0.86337744 357.00 -1.31509009e+01 4.22559261e+00 1.38131035e+01 2.83069656 0.91334235 357.25 -1.01163249e+01 2.41175618e+00 1.03998364e+01 2.90755881 0.93133278 357.50 -8.86142933e+00 1.51630451e+00 8.99022297e+00 2.97212109 0.94873215 357.75 -8.40635440e+00 -1.66875051e-01 8.40801056e+00 -3.12174420 0.90114676 358.00 -8.80895855e+00 -7.67384956e-01 8.84232042e+00 -3.05469787 0.84617937 358.25 -7.30185243e+00 3.12198979e+00 7.94127629e+00 2.73755453 0.76041368 358.50 -6.10670878e+00 3.59600553e+00 7.08682918e+00 2.60940351 0.85498964 358.75 -4.11397067e+00 2.78222894e+00 4.96644264e+00 2.54695868 0.87823549 359.00 -3.48282601e+00 2.33379287e+00 4.19245348e+00 2.55122657 0.90309569 359.25 -2.77894257e+00 1.55476281e+00 3.18430671e+00 2.63150027 0.89170425 359.50 -2.62373409e+00 1.30489026e+00 2.93031042e+00 2.68007459 0.90508804 359.75 -2.15701654e+00 1.05558111e+00 2.40145202e+00 2.68648443 0.87172607 360.00 -1.89416469e+00 8.07436981e-01 2.05908095e+00 2.73864170 0.85159154 360.25 -1.53278040e+00 6.16759466e-01 1.65221306e+00 2.75903664 0.86008137 360.50 -1.33909226e+00 5.69714763e-01 1.45524671e+00 2.73934220 0.80867517 360.75 -9.56442007e-01 4.94440665e-01 1.07668607e+00 2.66447060 0.68533131 361.00 -7.67975239e-01 5.48165320e-01 9.43541830e-01 2.52167815 0.59988703 361.25 -5.60272909e-01 5.85742551e-01 8.10555407e-01 2.33397363 0.46784434 361.50 -3.47748500e-02 3.29001263e-01 3.30833978e-01 1.67610355 0.07930875 361.75 5.14446181e-01 -4.45152454e-01 6.80305505e-01 -0.71331213 0.41768528 362.00 4.63287105e-01 -6.38891103e-01 7.89187419e-01 -0.94339472 0.48821422 362.25 2.93409470e-01 -9.61412163e-01 1.00518778e+00 -1.27458861 0.70894049 362.50 2.28977244e-01 -1.15763717e+00 1.18006542e+00 -1.37551986 0.78898192 362.75 9.08158023e-02 -1.46772607e+00 1.47053301e+00 -1.50899994 0.89901611 363.00 -1.40795904e-01 -1.49723755e+00 1.50384300e+00 -1.66455772 0.87540824 363.25 -4.49660308e-01 -1.42557793e+00 1.49481330e+00 -1.87634208 0.90359011 363.50 -5.47693711e-01 -1.17083584e+00 1.29260394e+00 -2.00833742 0.85610738 363.75 -5.24697237e-01 -8.76696564e-01 1.02171623e+00 -2.11010741 0.87553249 364.00 -4.00467078e-01 -7.77389821e-01 8.74476309e-01 -2.04648497 0.78999453 364.25 -2.09501253e-01 -7.36418514e-01 7.65638950e-01 -1.84796066 0.85029717 364.50 -1.56181379e-01 -7.98000532e-01 8.13140500e-01 -1.76406917 0.78359295 364.75 -1.79017036e-01 -9.30444658e-01 9.47509557e-01 -1.76087309 0.82589467 365.00 -2.96470132e-01 -9.14589456e-01 9.61440801e-01 -1.88426514 0.82327062 365.25 -3.01462049e-01 -7.96282147e-01 8.51436800e-01 -1.93270803 0.86770656 365.50 -1.20849631e-01 -7.63579383e-01 7.73083506e-01 -1.72776166 0.82464910 365.75 -1.16109718e-03 -8.33743790e-01 8.33744598e-01 -1.57218896 0.88980946 366.00 -2.81616944e-02 -8.91149692e-01 8.91594557e-01 -1.60238734 0.82679033 366.25 -1.88920415e-01 -1.01497935e+00 1.03241175e+00 -1.75482268 0.87721678 366.50 -3.14277322e-01 -9.66245725e-01 1.01607137e+00 -1.88525985 0.87489099 366.75 -4.34009860e-01 -8.72732977e-01 9.74693494e-01 -2.03228138 0.87370443 367.00 -5.20419281e-01 -6.69866773e-01 8.48267482e-01 -2.23129214 0.80323923 367.25 -5.70617979e-01 -5.21043428e-01 7.72716722e-01 -2.40157533 0.78698890 367.50 -3.09823170e-01 -2.76078582e-01 4.14981663e-01 -2.41372521 0.41872464 367.75 -1.51574801e-01 -1.28709428e-01 1.98849282e-01 -2.43759347 0.15926018 368.00 1.15997167e-01 -1.09360206e-01 1.59420819e-01 -0.75595585 0.09204007 368.25 2.21123599e-01 -1.96718453e-01 2.95962491e-01 -0.72705686 0.27430669 368.50 2.79657683e-01 -1.12405085e-01 3.01402261e-01 -0.38217606 0.20501323 368.75 4.01485682e-01 -9.46898940e-02 4.12500823e-01 -0.23161613 0.37801474 369.00 6.93075294e-01 -1.50509785e-01 7.09229552e-01 -0.21384195 0.54746033 369.25 8.26765061e-01 -2.87416665e-01 8.75299266e-01 -0.33457089 0.58433843 369.50 9.94019684e-01 -6.57752242e-01 1.19193672e+00 -0.58456284 0.70008271 369.75 1.15053135e+00 -9.55716829e-01 1.49569952e+00 -0.69316696 0.75494359 370.00 1.03509154e+00 -1.65384368e+00 1.95105444e+00 -1.01157146 0.87429109 370.25 6.53478281e-01 -1.67466690e+00 1.79764932e+00 -1.19875462 0.88530460 370.50 3.87713804e-01 -1.41640447e+00 1.46851068e+00 -1.30361028 0.94560827 370.75 4.30070720e-01 -1.38662542e+00 1.45178886e+00 -1.27004799 0.94056068 371.00 4.52058405e-01 -1.50064177e+00 1.56725318e+00 -1.27819920 0.94522881 371.25 3.95991945e-01 -1.56654707e+00 1.61582157e+00 -1.32320280 0.94187160 371.50 1.45251359e-01 -1.74109661e+00 1.74714492e+00 -1.48756385 0.95967096 371.75 2.26275837e-02 -1.76110274e+00 1.76124810e+00 -1.55794850 0.95844808 372.00 -1.61568837e-01 -1.78117424e+00 1.78848711e+00 -1.66125793 0.96997730 372.25 -2.99420745e-01 -1.70976568e+00 1.73578555e+00 -1.74416216 0.95335409 372.50 -6.72298545e-01 -1.62010269e+00 1.75405760e+00 -1.96414328 0.95789159 372.75 -7.96198427e-01 -1.52310391e+00 1.71865571e+00 -2.05247572 0.95512181 373.00 -9.51491769e-01 -1.33161895e+00 1.63662629e+00 -2.19121256 0.94902854 373.25 -1.01284853e+00 -1.08249491e+00 1.48244979e+00 -2.32296807 0.94108881 373.50 -1.02510885e+00 -8.36035843e-01 1.32280160e+00 -2.45743679 0.95319370 373.75 -8.87006682e-01 -7.05223829e-01 1.13319085e+00 -2.46987097 0.94853331 374.00 -8.17479167e-01 -6.39382636e-01 1.03782578e+00 -2.47783762 0.96208555 374.25 -8.31253360e-01 -5.54831217e-01 9.99409740e-01 -2.55303865 0.94809056 374.50 -7.19264828e-01 -4.16795308e-01 8.31300320e-01 -2.61640250 0.94251743 374.75 -6.42837155e-01 -2.90036390e-01 7.05238056e-01 -2.71775642 0.90244816 375.00 -5.50542976e-01 -1.82447082e-01 5.79986643e-01 -2.82158779 0.90592102 375.25 -3.44048245e-01 -1.84355589e-01 3.90328296e-01 -2.64968405 0.75896997 375.50 -1.52467171e-01 -2.13304145e-01 2.62192480e-01 -2.19137811 0.62842719 375.75 2.19260949e-02 -3.30496935e-01 3.31223456e-01 -1.50455059 0.58804925 376.00 1.36829724e-01 -5.14019703e-01 5.31919757e-01 -1.31063389 0.79135228 376.25 7.21327288e-02 -8.73050918e-01 8.76025705e-01 -1.48836211 0.84875487 376.50 -2.87490089e-02 -1.06865291e+00 1.06903955e+00 -1.59769194 0.93497684 376.75 -3.49820102e-01 -1.13039756e+00 1.18328896e+00 -1.87091514 0.92530740 377.00 -5.64018199e-01 -1.06145956e+00 1.20200371e+00 -2.05921683 0.94021886 377.25 -6.80737373e-01 -7.98944128e-01 1.04962617e+00 -2.27647716 0.92378327 377.50 -7.25304621e-01 -6.67698424e-01 9.85843791e-01 -2.39752490 0.94697109 377.75 -6.24408874e-01 -5.26212297e-01 8.16569546e-01 -2.44133043 0.93174298 378.00 -5.68253076e-01 -4.65888918e-01 7.34822456e-01 -2.45485772 0.94042680 378.25 -5.02982624e-01 -4.43503219e-01 6.70586777e-01 -2.41895432 0.91849636 378.50 -4.70291769e-01 -4.45660993e-01 6.47910541e-01 -2.38307889 0.92012281 378.75 -4.41823289e-01 -4.50806574e-01 6.31216592e-01 -2.34613099 0.91035825 379.00 -4.29198845e-01 -4.35810490e-01 6.11671834e-01 -2.34855120 0.91422836 379.25 -3.74950822e-01 -4.48426436e-01 5.84529202e-01 -2.26719336 0.90048813 379.50 -3.78176340e-01 -4.61529497e-01 5.96679831e-01 -2.25725390 0.88853616 379.75 -4.10686268e-01 -5.08931597e-01 6.53968334e-01 -2.24976539 0.86928659 380.00 -4.12182544e-01 -5.08585835e-01 6.54640360e-01 -2.25187582 0.87563031 380.25 -3.89950449e-01 -5.00828377e-01 6.34736494e-01 -2.23235841 0.87401039 380.50 -3.73902897e-01 -5.36315573e-01 6.53787251e-01 -2.17962015 0.89708050 380.75 -3.25278683e-01 -6.16299225e-01 6.96872267e-01 -2.05643066 0.92554168 381.00 -3.10176559e-01 -6.23248009e-01 6.96166344e-01 -2.03258427 0.89828211 381.25 -2.66444514e-01 -6.96933564e-01 7.46129394e-01 -1.93596012 0.88875127 381.50 -2.95087464e-01 -8.18361101e-01 8.69937643e-01 -1.91686832 0.91562629 381.75 -4.83307941e-01 -9.61087963e-01 1.07576793e+00 -2.03674198 0.90273564 382.00 -6.08904402e-01 -1.04193732e+00 1.20681314e+00 -2.09966356 0.90617195 382.25 -1.03808447e+00 -1.06239617e+00 1.48536359e+00 -2.34462065 0.88219208 382.50 -1.20527461e+00 -8.53061538e-01 1.47661805e+00 -2.52566855 0.84822294 382.75 -1.55367000e+00 -4.11042422e-01 1.60712362e+00 -2.88295600 0.89735300 383.00 -1.41089986e+00 -6.93341955e-02 1.41260244e+00 -3.09249033 0.82772748 383.25 -1.25115497e+00 3.62183967e-01 1.30252293e+00 2.85981523 0.90416903 383.50 -9.68473759e-01 4.00722218e-01 1.04810291e+00 2.74927503 0.86227443 383.75 -6.86697055e-01 3.60903845e-01 7.75760550e-01 2.65770294 0.83364757 384.00 -5.16924947e-01 3.20749835e-01 6.08351755e-01 2.58623877 0.72168363 384.25 -3.55483409e-01 1.33280106e-01 3.79647258e-01 2.78288653 0.54948512 384.50 -2.93030822e-01 4.62052986e-02 2.96651297e-01 2.98519964 0.46367224 384.75 -2.42383990e-01 -1.01336706e-01 2.62714915e-01 -2.74559504 0.41325872 385.00 -2.97816720e-01 -2.49571571e-01 3.88562438e-01 -2.44410431 0.55588471 385.25 -4.28107564e-01 -4.30934584e-01 6.07437817e-01 -2.35290360 0.80270330 385.50 -5.83913974e-01 -4.18192497e-01 7.18220366e-01 -2.52008432 0.82326030 385.75 -7.33696171e-01 -3.80188800e-01 8.26349560e-01 -2.66350477 0.88141139 386.00 -8.30233489e-01 -3.23669030e-01 8.91094432e-01 -2.76986416 0.86223474 386.25 -8.98095625e-01 -2.47104050e-01 9.31469894e-01 -2.87309420 0.90601679 386.50 -9.38772573e-01 -1.39992843e-01 9.49153275e-01 -2.99356025 0.85851546 386.75 -9.44895889e-01 -9.20670132e-02 9.49370621e-01 -3.04446311 0.87963087 387.00 -9.86865026e-01 1.10181152e-01 9.92996710e-01 3.03040548 0.87466518 387.25 -1.00794281e+00 2.28307487e-01 1.03347619e+00 2.91884298 0.90595226 387.50 -8.91539551e-01 3.14171375e-01 9.45275845e-01 2.80278850 0.86130621 387.75 -8.44994763e-01 3.62341081e-01 9.19405899e-01 2.73650046 0.88455545 388.00 -7.94313845e-01 3.85035501e-01 8.82715595e-01 2.69022760 0.87030512 388.25 -7.40294237e-01 4.28603516e-01 8.55415999e-01 2.61678462 0.89570746 388.50 -6.93390751e-01 4.18043105e-01 8.09660899e-01 2.59904583 0.88988964 388.75 -6.90331662e-01 4.15295910e-01 8.05623048e-01 2.60000562 0.91041261 389.00 -6.20572742e-01 4.15291602e-01 7.46711218e-01 2.55183344 0.88954288 389.25 -6.28623256e-01 4.61512528e-01 7.79846787e-01 2.50830390 0.90299374 389.50 -6.33738455e-01 5.63635080e-01 8.48120825e-01 2.41467535 0.89672146 389.75 -5.85850343e-01 6.31804541e-01 8.61624978e-01 2.31847247 0.90851916 390.00 -4.34694716e-01 7.29259501e-01 8.48986994e-01 2.10832617 0.88130565 390.25 -3.42337306e-01 7.58831272e-01 8.32478065e-01 1.99459586 0.88832735 390.50 -1.97503774e-01 6.84173178e-01 7.12110018e-01 1.85183122 0.83853749 390.75 -8.87194525e-02 6.48261243e-01 6.54304043e-01 1.70680892 0.78502341 391.00 -2.21554963e-02 5.43009215e-01 5.43461014e-01 1.61157503 0.72005571 391.25 -9.81827724e-03 4.59522688e-01 4.59627566e-01 1.59215933 0.59355339 391.50 5.77975341e-02 4.20623012e-01 4.24575404e-01 1.43424213 0.58333580 391.75 5.21557914e-02 3.54058768e-01 3.57879642e-01 1.42453989 0.47387801 392.00 1.49252977e-02 2.49923248e-01 2.50368517e-01 1.51114764 0.41976791 392.25 3.20401922e-03 2.50979379e-01 2.50999830e-01 1.55803095 0.48933387 392.50 -2.73932028e-02 2.34702880e-01 2.36296064e-01 1.68698503 0.54827126 392.75 -2.52117948e-02 2.13196607e-01 2.14682156e-01 1.68850573 0.47321757 393.00 -2.75378578e-02 1.97207483e-01 1.99120881e-01 1.70953820 0.35282815 393.25 -5.98242526e-02 1.25705534e-01 1.39215022e-01 2.01498514 0.17318366 393.50 -8.04050261e-02 5.34901624e-02 9.65720751e-02 2.55456526 0.08363309 393.75 -1.41967566e-01 2.70194294e-02 1.44515879e-01 2.95352077 0.17172200 394.00 -1.55782421e-01 1.03283154e-01 1.86910601e-01 2.55613544 0.29807098 394.25 -1.48105940e-01 1.60217228e-01 2.18185540e-01 2.31693353 0.40525383 394.50 -1.17052995e-01 2.15615614e-01 2.45339553e-01 2.06815523 0.62850957 394.75 -3.77483563e-02 2.43862823e-01 2.46767127e-01 1.72437087 0.49513046 395.00 5.37366989e-02 1.43241390e-01 1.52989309e-01 1.21189604 0.24099168 395.25 5.93344428e-02 4.44467692e-02 7.41356284e-02 0.64291771 0.05854462 395.50 5.09974374e-02 -4.41571085e-02 6.74580525e-02 -0.71363509 0.04845089 395.75 -2.47314389e-02 -1.66045862e-01 1.67877551e-01 -1.71865279 0.15031512 396.00 -2.03544176e-01 -2.64525056e-01 3.33771983e-01 -2.22664243 0.42695865 396.25 -3.97658919e-01 -1.20076934e-01 4.15392689e-01 -2.84833902 0.55159141 396.50 -4.76460195e-01 -9.00176069e-03 4.76545223e-01 -3.12270190 0.78834569 396.75 -4.55403362e-01 6.67212937e-02 4.60265090e-01 2.99611733 0.75689174 397.00 -4.06308940e-01 1.25788268e-01 4.25334743e-01 2.84136314 0.76326735 397.25 -3.60950798e-01 2.10894003e-01 4.18045164e-01 2.61281699 0.74364269 397.50 -3.02772130e-01 2.80361524e-01 4.12642153e-01 2.39460692 0.70447308 397.75 -1.67441970e-01 2.91533983e-01 3.36197675e-01 2.09214050 0.63243935 398.00 -1.04798347e-01 2.33716338e-01 2.56136722e-01 1.99231869 0.59047741 398.25 -8.73768410e-02 1.07186635e-01 1.38288420e-01 2.25472754 0.24867370 398.50 -8.88226565e-02 6.69236151e-02 1.11212565e-01 2.49588587 0.26278549 398.75 -1.19419588e-01 2.58260068e-02 1.22180279e-01 2.92860986 0.26889964 399.00 -1.62311403e-01 3.12096488e-02 1.65284705e-01 2.95162862 0.45879794 399.25 -2.09960032e-01 2.74404580e-02 2.11745588e-01 3.01163552 0.62672801 399.50 -2.28456671e-01 1.93882546e-02 2.29277899e-01 3.05692930 0.69757321 399.75 -2.31033101e-01 2.07912014e-02 2.31966738e-01 3.05184211 0.68554314 400.00 -2.50840561e-01 4.69602962e-02 2.55198464e-01 2.95652319 0.74869732 400.25 -2.34390243e-01 7.52742662e-02 2.46180830e-01 2.83084750 0.71828439 400.50 -2.18641059e-01 9.24548953e-02 2.37385383e-01 2.74153469 0.66418799 400.75 -1.81637344e-01 1.06609328e-01 2.10612614e-01 2.61083511 0.66281587 401.00 -1.60328438e-01 9.06340611e-02 1.84173128e-01 2.62707687 0.58198884 401.25 -1.25148181e-01 -2.67559740e-03 1.25176779e-01 -3.12021648 0.34275318 401.50 -1.30472396e-01 -6.37353364e-02 1.45207573e-01 -2.68718995 0.39924840 401.75 -2.18640967e-01 -1.42239655e-01 2.60837099e-01 -2.56482197 0.58353502 402.00 -2.63768479e-01 -1.83901799e-01 3.21548880e-01 -2.53274219 0.60987491 402.25 -3.85911982e-01 -2.66940555e-01 4.69239084e-01 -2.53644973 0.78453679 402.50 -4.76438665e-01 -2.33058655e-01 5.30386781e-01 -2.68664796 0.75758178 402.75 -6.84443479e-01 -8.00255094e-02 6.89105912e-01 -3.02520056 0.80517532 403.00 -7.24284109e-01 6.02917903e-02 7.26789220e-01 3.05854085 0.80001727 403.25 -6.41277865e-01 1.89911865e-01 6.68807758e-01 2.85367539 0.79007417 403.50 -6.07273602e-01 2.50190335e-01 6.56792533e-01 2.75079344 0.71065093 403.75 -5.27977853e-01 4.47357542e-01 6.92018341e-01 2.43866607 0.70868144 404.00 -4.19061830e-01 5.20616343e-01 6.68321924e-01 2.24853861 0.69021572 404.25 -2.61279618e-01 5.55943021e-01 6.14279807e-01 2.01013718 0.77078135 404.50 -1.95577076e-01 5.52893935e-01 5.86465767e-01 1.91079327 0.67106284 404.75 -6.92169951e-02 4.80704650e-01 4.85662386e-01 1.71380408 0.62850665 405.00 -4.92516988e-02 4.01119998e-01 4.04132383e-01 1.69297025 0.53766349 405.25 -7.96449080e-02 3.51150588e-01 3.60069503e-01 1.79383408 0.62019641 405.50 -7.98519984e-02 2.57839541e-01 2.69921416e-01 1.87112506 0.41482719 405.75 -8.78511378e-02 1.62916366e-01 1.85093394e-01 2.06534154 0.35864588 406.00 -1.30768152e-01 1.47139193e-01 1.96850837e-01 2.29735422 0.33583174 406.25 -1.77331600e-01 1.37182555e-01 2.24199799e-01 2.48316197 0.48301133 406.50 -2.17625945e-01 1.75718867e-01 2.79710873e-01 2.46233442 0.50310518 406.75 -2.21142832e-01 2.19266835e-01 3.11419488e-01 2.36045413 0.57098413 407.00 -2.61000483e-01 2.07775905e-01 3.33604674e-01 2.46924972 0.56004688 407.25 -2.60050996e-01 2.25306428e-01 3.44077763e-01 2.42765811 0.66896502 407.50 -2.24679451e-01 2.40183482e-01 3.28890500e-01 2.32285502 0.54995619 407.75 -2.14171777e-01 2.50408205e-01 3.29505416e-01 2.27835383 0.57487965 408.00 -2.29774230e-01 2.20632627e-01 3.18551335e-01 2.37648803 0.44886380 408.25 -2.53548956e-01 2.25349964e-01 3.39219220e-01 2.41500955 0.56919526 408.50 -1.88784052e-01 3.04575328e-01 3.58337200e-01 2.12566718 0.49344289 408.75 -2.13750092e-01 3.37422792e-01 3.99428645e-01 2.13546934 0.64420110 409.00 -2.02754772e-01 3.38961584e-01 3.94973990e-01 2.10986507 0.53111184 409.25 -2.18314647e-01 3.57579004e-01 4.18955880e-01 2.11892647 0.55789180 409.50 -1.06442821e-01 3.85141339e-01 3.99579686e-01 1.84043893 0.52329371 409.75 -1.00483195e-01 3.69391631e-01 3.82814641e-01 1.83639319 0.55718890 410.00 2.95384733e-02 2.79549435e-01 2.81105689e-01 1.46552238 0.32819746 410.25 6.63383333e-02 2.97931681e-01 3.05227883e-01 1.35170748 0.40862571 410.50 1.60873249e-02 2.81635798e-01 2.82094886e-01 1.51373731 0.31464907 410.75 3.34879443e-02 2.61523358e-01 2.63658699e-01 1.44343985 0.30888984 411.00 -2.80462827e-02 2.26479625e-01 2.28209584e-01 1.69400486 0.25569574 411.25 -4.92509803e-03 2.36401157e-01 2.36452455e-01 1.59162696 0.23913947 411.50 -5.15075085e-02 2.04290196e-01 2.10683430e-01 1.81777787 0.19998892 411.75 -7.45437752e-02 1.49165148e-01 1.66754358e-01 2.03423583 0.11411729 412.00 -1.29642105e-01 1.22466588e-01 1.78339958e-01 2.38464881 0.09857768 412.25 -1.82096155e-01 8.45626036e-02 2.00773114e-01 2.70684130 0.09543222 412.50 -2.23341232e-01 7.01204541e-02 2.34090119e-01 2.83737725 0.11492341 412.75 -2.60145969e-01 5.72847297e-02 2.66378425e-01 2.92484944 0.11241595 413.00 -2.67804691e-01 1.55592073e-01 3.09722853e-01 2.61526775 0.12739828 413.25 -1.97594564e-01 2.61903175e-01 3.28080607e-01 2.21714353 0.10786854 413.50 -1.34373652e-01 3.84674910e-01 4.07469097e-01 1.90686294 0.18882889 413.75 -1.94318985e-01 3.01457985e-01 3.58659706e-01 2.14336409 0.16108249 414.00 -3.78604690e-01 2.37850272e-01 4.47117728e-01 2.58067506 0.29152087 414.25 -4.97773249e-01 3.45788153e-01 6.06092117e-01 2.53445282 0.28055815 414.50 -9.23516296e-01 6.80536526e-01 1.14717580e+00 2.50653024 0.42166214 414.75 -6.85884857e-01 8.79942454e-01 1.11567771e+00 2.23289027 0.26520609 415.00 3.31884299e-01 1.39541900e+00 1.43434353e+00 1.33729617 0.36814721 415.25 9.05726200e-01 1.33173968e+00 1.61054976e+00 0.97354613 0.52309762 415.50 1.11681051e+00 1.27357624e+00 1.69388965e+00 0.85088613 0.72510752 415.75 1.27512727e+00 1.11378940e+00 1.69306715e+00 0.71796457 0.67467767 416.00 1.43849673e+00 9.53294138e-01 1.72570060e+00 0.58525256 0.75049510 416.25 1.64466580e+00 7.10253398e-01 1.79147579e+00 0.40766061 0.75854713 416.50 1.80501874e+00 4.36129937e-01 1.85696041e+00 0.23707687 0.81646140 416.75 1.69294828e+00 2.85487811e-01 1.71685094e+00 0.16706175 0.81250376 417.00 1.70626050e+00 3.24047238e-01 1.73675891e+00 0.18768148 0.86331666 417.25 1.84429417e+00 2.74088411e-01 1.86454966e+00 0.14753442 0.83895758 417.50 1.86137498e+00 2.34119512e-01 1.87604072e+00 0.12512068 0.87791215 417.75 2.02858449e+00 2.94511414e-01 2.04985170e+00 0.14417344 0.84877690 418.00 2.27776234e+00 3.77970034e-01 2.30890940e+00 0.16444078 0.88603950 418.25 2.71119431e+00 3.02537494e-01 2.72802191e+00 0.11112854 0.88678140 418.50 3.02858657e+00 2.12733718e-01 3.03604879e+00 0.07012673 0.91216489 418.75 3.60723887e+00 3.49916197e-01 3.62417075e+00 0.09670133 0.79875816 419.00 4.54187101e+00 3.86833428e-01 4.55831464e+00 0.08496545 0.85408461 419.25 5.53248187e+00 4.66203398e-02 5.53267829e+00 0.00842646 0.74589867 419.50 6.78319497e+00 -5.74294331e-01 6.80746267e+00 -0.08446286 0.73384519 419.75 6.03161634e+00 -2.40946497e+00 6.49506868e+00 -0.38005157 0.42003174 420.00 3.41103442e+00 -3.94292188e+00 5.21361571e+00 -0.85759915 0.23087636 420.25 -3.92669139e-01 -6.60285000e+00 6.61451564e+00 -1.63019601 0.37077775 420.50 -7.38224695e-01 -7.42212348e+00 7.45874605e+00 -1.66993300 0.52799616 420.75 -2.45163471e+00 -7.87881508e+00 8.25143865e+00 -1.87246719 0.60556177 421.00 -3.39622927e+00 -7.78795901e+00 8.49627441e+00 -1.98202033 0.65798112 421.25 -4.33050826e+00 -6.90716368e+00 8.15243595e+00 -2.13080310 0.75688312 421.50 -5.07842935e+00 -6.63690137e+00 8.35696742e+00 -2.22394255 0.79132569 421.75 -5.70885255e+00 -5.14920508e+00 7.68799781e+00 -2.40769106 0.80366682 422.00 -5.87150830e+00 -4.81615472e+00 7.59407374e+00 -2.45462044 0.83212669 422.25 -4.95543445e+00 -4.15741549e+00 6.46841821e+00 -2.44354240 0.88268678 422.50 -4.23474288e+00 -4.01427167e+00 5.83501708e+00 -2.38291510 0.87437365 422.75 -2.99755313e+00 -3.75611894e+00 4.80559613e+00 -2.24434425 0.87303308 423.00 -2.15881117e+00 -3.83331092e+00 4.39940203e+00 -2.08369569 0.86586766 423.25 -7.46948181e-01 -4.44510024e+00 4.50742141e+00 -1.73727951 0.85380710 423.50 2.91204173e-01 -4.43974124e+00 4.44928108e+00 -1.50529980 0.79271300 423.75 2.93943601e+00 -4.22297153e+00 5.14526701e+00 -0.96272044 0.79952947 424.00 3.71151141e+00 -4.08335112e+00 5.51806790e+00 -0.83306521 0.79298170 424.25 5.55152093e+00 -2.61761803e+00 6.13769572e+00 -0.44059997 0.79865408 424.50 5.53342141e+00 -1.51585010e+00 5.73729501e+00 -0.26738461 0.76228906 424.75 5.33779369e+00 -3.74069069e-01 5.35088489e+00 -0.06996496 0.81066696 425.00 5.63920814e+00 5.12539653e-01 5.66245224e+00 0.09063955 0.82309841 425.25 6.22521967e+00 1.14469889e+00 6.32958889e+00 0.18184947 0.88885584 425.50 5.99645232e+00 1.04672241e+00 6.08712315e+00 0.17281575 0.86770129 425.75 6.26252075e+00 7.92863053e-01 6.31251123e+00 0.12593446 0.89626809 426.00 6.06403750e+00 7.27188466e-01 6.10748343e+00 0.11934829 0.87413486 426.25 5.84472699e+00 1.18877696e-02 5.84473908e+00 0.00203393 0.86639224 426.50 5.64693415e+00 -8.21030463e-01 5.70630847e+00 -0.14438231 0.85158240 426.75 5.56714252e+00 -1.57390333e+00 5.78534766e+00 -0.27552265 0.91033018 427.00 4.57635720e+00 -1.88648260e+00 4.94993554e+00 -0.39099938 0.88123208 427.25 3.91189053e+00 -2.22035377e+00 4.49809497e+00 -0.51624838 0.90965756 427.50 2.99300275e+00 -2.15309465e+00 3.68698821e+00 -0.62361204 0.87328329 427.75 2.24756869e+00 -1.95603676e+00 2.97953768e+00 -0.71615621 0.86381569 428.00 1.56059818e+00 -1.87426688e+00 2.43892251e+00 -0.87646466 0.82799314 428.25 1.29170390e+00 -1.63430554e+00 2.08313551e+00 -0.90195580 0.82735929 428.50 8.49195699e-01 -1.05713999e+00 1.35597872e+00 -0.89404922 0.71429891 428.75 5.68654446e-01 -7.04669390e-01 9.05498111e-01 -0.89181346 0.54678017 429.00 2.47526519e-01 -2.26528705e-01 3.35536334e-01 -0.74113307 0.16457713 429.25 1.09191975e-01 -4.29805098e-02 1.17346545e-01 -0.37499720 0.03036710 429.50 1.10695633e-01 2.27249561e-01 2.52776356e-01 1.11751344 0.10443026 429.75 2.14810161e-01 3.90578130e-01 4.45751815e-01 1.06796847 0.23728106 430.00 5.46193108e-01 4.69123581e-01 7.20002671e-01 0.70963656 0.40291000 430.25 8.25159995e-01 4.89425797e-01 9.59388675e-01 0.53535150 0.59103968 430.50 8.84906756e-01 4.37993668e-01 9.87369445e-01 0.45960769 0.62115891 430.75 7.29514235e-01 4.09631040e-01 8.36653218e-01 0.51163866 0.53922846 431.00 5.54113463e-01 6.91712034e-01 8.86288479e-01 0.89540002 0.58779089 431.25 5.19947553e-01 8.04698036e-01 9.58062830e-01 0.99713946 0.62839081 431.50 5.84347879e-01 1.00867202e+00 1.16571080e+00 1.04571854 0.59789949 431.75 9.21224019e-01 1.26582126e+00 1.56555331e+00 0.94167628 0.68477666 432.00 1.58740885e+00 1.45227132e+00 2.15150154e+00 0.74096961 0.76524063 432.25 1.95389208e+00 1.34931302e+00 2.37451887e+00 0.60437380 0.77639133 432.50 2.30112637e+00 2.70964585e-01 2.31702489e+00 0.11721326 0.69371488 432.75 2.15055004e+00 -4.64817982e-01 2.20020937e+00 -0.21286469 0.72844189 433.00 1.54236310e+00 -7.76773698e-01 1.72692249e+00 -0.46654396 0.78218742 433.25 1.28675359e+00 -8.23150726e-01 1.52751822e+00 -0.56910831 0.73707129 433.50 8.90637576e-01 -6.87255107e-01 1.12496883e+00 -0.65720995 0.65074453 433.75 6.33208818e-01 -6.89633093e-01 9.36241000e-01 -0.82802616 0.54434148 434.00 3.56854852e-01 -5.01045654e-01 6.15135865e-01 -0.95191586 0.38543040 434.25 2.72443225e-01 -3.42701986e-01 4.37801281e-01 -0.89912029 0.20364267 434.50 -8.16935976e-02 -2.25424389e-01 2.39770722e-01 -1.91847414 0.08753541 434.75 -1.47341592e-01 -1.59922056e-01 2.17450244e-01 -2.31527380 0.06210696 435.00 -1.43449442e-01 -3.74200285e-03 1.43498240e-01 -3.11551270 0.02647995 435.25 -1.42474539e-01 3.91452840e-03 1.42528305e-01 3.11412428 0.01561707 435.50 -1.82634682e-01 3.98244401e-01 4.38125587e-01 2.00077854 0.04560701 435.75 -2.14368215e-01 9.00599938e-01 9.25761297e-01 1.80447610 0.09849522 436.00 -2.39018429e-01 2.03206997e+00 2.04607873e+00 1.68788147 0.42110527 436.25 1.53703741e-01 2.26312153e+00 2.26833505e+00 1.50298377 0.61011628 436.50 2.07518322e-01 2.54937932e+00 2.55781132e+00 1.48957585 0.80162917 436.75 3.64773967e-01 2.61723589e+00 2.64253358e+00 1.43231465 0.81856860 437.00 7.25897164e-01 2.84292953e+00 2.93413956e+00 1.32080357 0.85321877 437.25 1.17175211e+00 3.07655250e+00 3.29213887e+00 1.20689341 0.87911983 437.50 1.54850302e+00 3.25111750e+00 3.60105909e+00 1.12628890 0.91320977 437.75 1.89278369e+00 3.29181814e+00 3.79719591e+00 1.04896473 0.86190666 438.00 2.68158740e+00 2.99386363e+00 4.01922012e+00 0.84036501 0.88443173 438.25 3.05108984e+00 2.80707267e+00 4.14593851e+00 0.74376801 0.84911993 438.50 3.52209430e+00 2.78388491e+00 4.48945023e+00 0.66886358 0.90166313 438.75 3.63862612e+00 2.50553395e+00 4.41783888e+00 0.60302944 0.86300757 439.00 3.86174029e+00 2.48858559e+00 4.59413716e+00 0.57244307 0.88839461 439.25 3.98166384e+00 2.48718810e+00 4.69465138e+00 0.55835514 0.84868127 439.50 4.17475857e+00 2.48198598e+00 4.85683678e+00 0.53638185 0.84234991 439.75 4.14389812e+00 3.31407800e+00 5.30612897e+00 0.67458782 0.73564231 440.00 4.89459191e+00 4.19714702e+00 6.44771844e+00 0.70883618 0.73544194 440.25 4.67719837e+00 4.92611605e+00 6.79284947e+00 0.81131234 0.65986747 440.50 3.56920655e+00 5.68222663e+00 6.71021124e+00 1.00994566 0.57329157 440.75 -3.14630157e+00 4.68795644e+00 5.64589666e+00 2.16189336 0.45777668 441.00 -4.14048316e+00 2.49212414e+00 4.83262698e+00 2.59978306 0.51908452 441.25 -3.66592673e+00 3.35307223e-01 3.68122938e+00 3.05038057 0.63619853 441.50 -3.18610046e+00 -1.63863898e-01 3.19031151e+00 -3.09020707 0.68902908 441.75 -1.89329333e+00 -7.19823596e-01 2.02551368e+00 -2.77827390 0.59504927 442.00 -1.65546338e+00 -8.32458140e-01 1.85298288e+00 -2.67566360 0.60870897 442.25 -1.17995077e+00 -8.25649446e-01 1.44013222e+00 -2.53104650 0.51717346 442.50 -1.13108094e+00 -7.77424393e-01 1.37249145e+00 -2.53942164 0.54403007 442.75 -1.17529149e+00 -3.62414828e-01 1.22990024e+00 -2.84248238 0.36428784 443.00 -6.71549296e-01 -1.03814691e-01 6.79526266e-01 -2.98821693 0.17406079 443.25 -1.11819095e-02 -2.60404051e-02 2.83396859e-02 -1.97639308 0.00061571 443.50 2.95318295e-01 -8.49955482e-02 3.07306262e-01 -0.28023610 0.08835228 443.75 7.03317373e-01 -2.85935806e-01 7.59219739e-01 -0.38614274 0.32097604 444.00 9.82950568e-01 -4.48537996e-01 1.08045275e+00 -0.42809550 0.47368334 444.25 1.33785633e+00 -8.14681956e-01 1.56638637e+00 -0.54697132 0.69036831 444.50 1.20002965e+00 -1.22322519e+00 1.71357843e+00 -0.79496993 0.67648850 444.75 7.67090485e-01 -1.86984327e+00 2.02107439e+00 -1.18149091 0.78450471 445.00 3.77872244e-01 -1.99191155e+00 2.02743657e+00 -1.38332073 0.80300993 445.25 1.50575023e-01 -2.01672060e+00 2.02233400e+00 -1.49627130 0.87323300 445.50 1.02474249e-01 -1.92858258e+00 1.93130312e+00 -1.51771176 0.87269136 445.75 2.26655556e-02 -1.84057549e+00 1.84071504e+00 -1.55848256 0.87100368 446.00 -1.37099636e-01 -1.80359038e+00 1.80879368e+00 -1.64666526 0.84026941 446.25 -4.09925546e-01 -1.73830945e+00 1.78598956e+00 -1.80238382 0.89109523 446.50 -4.43884546e-01 -1.70482190e+00 1.76166149e+00 -1.82551096 0.87477408 446.75 -5.50145845e-01 -1.69118509e+00 1.77841712e+00 -1.88530132 0.88235077 447.00 -7.22673577e-01 -1.63203307e+00 1.78487788e+00 -1.98765140 0.85103905 447.25 -8.87991301e-01 -1.37259546e+00 1.63479260e+00 -2.14501965 0.85765707 447.50 -1.00754036e+00 -1.24003441e+00 1.59775558e+00 -2.25311891 0.88769810 447.75 -1.20816303e+00 -1.15554616e+00 1.67180885e+00 -2.37845111 0.89825579 448.00 -1.22391442e+00 -9.88966272e-01 1.57353767e+00 -2.46197120 0.83197793 448.25 -1.07608008e+00 -7.27920073e-01 1.29915972e+00 -2.54684388 0.79866416 448.50 -9.50085892e-01 -4.50056240e-01 1.05129150e+00 -2.69920506 0.70434680 448.75 -9.56176593e-01 -2.60688229e-01 9.91076197e-01 -2.87542550 0.75051879 449.00 -8.57241711e-01 -5.42623294e-02 8.58957363e-01 -3.07837824 0.67771750 449.25 -7.09106046e-01 2.38995661e-02 7.09508684e-01 3.10790161 0.63987842 449.50 -6.23402731e-01 5.54613174e-02 6.25864939e-01 3.05286079 0.47800128 449.75 -6.20427315e-01 6.19093436e-02 6.23508477e-01 3.04213687 0.42866191 450.00 -4.10354941e-01 1.34987188e-01 4.31986942e-01 2.82379023 0.32738206 450.25 -3.27019767e-01 1.84991657e-01 3.75717768e-01 2.62678359 0.37282930 450.50 -2.43649753e-01 2.04138019e-01 3.17864016e-01 2.44420419 0.34430495 450.75 -1.92239460e-01 2.08340312e-01 2.83481385e-01 2.31602224 0.32580532 451.00 -1.54081983e-01 2.48152214e-01 2.92097208e-01 2.12645432 0.32714217 451.25 -9.06903033e-02 2.98906930e-01 3.12362104e-01 1.86537541 0.36924802 451.50 -5.49822630e-02 3.40620883e-01 3.45029905e-01 1.73083366 0.29600234 451.75 5.03854488e-02 3.24377074e-01 3.28266933e-01 1.41669791 0.24186938 452.00 1.05638793e-01 3.40864056e-01 3.56858318e-01 1.27026845 0.27464223 452.25 1.06498492e-01 4.02284009e-01 4.16142226e-01 1.31199861 0.37046092 452.50 3.55273626e-01 4.98673141e-01 6.12286086e-01 0.95177149 0.49919545 452.75 4.53167522e-01 5.61192810e-01 7.21316971e-01 0.89149425 0.55774924 453.00 6.80279871e-01 4.96324454e-01 8.42091840e-01 0.63030934 0.60074853 453.25 8.13420539e-01 3.05497761e-01 8.68896919e-01 0.35927182 0.57426851 453.50 9.58675284e-01 2.80502178e-01 9.98869247e-01 0.28464809 0.67391976 453.75 1.05526932e+00 2.28303591e-01 1.07968322e+00 0.21306260 0.64866358 454.00 1.50906200e+00 -3.30916895e-02 1.50942478e+00 -0.02192513 0.55940016 454.25 1.70277099e+00 -3.13663996e-01 1.73141969e+00 -0.18216584 0.52571037 454.50 1.63736739e+00 -8.51167766e-01 1.84538845e+00 -0.47939272 0.48025068 454.75 1.28286157e+00 -1.02209431e+00 1.64024711e+00 -0.67274386 0.35904570 455.00 4.85309606e-01 -1.56282384e+00 1.63644241e+00 -1.26970374 0.43703705 455.25 2.77945217e-01 -1.50235705e+00 1.52785151e+00 -1.38785866 0.39656080 455.50 -3.97254726e-01 -1.01737340e+00 1.09218128e+00 -1.94306108 0.31278653 455.75 -7.60697527e-01 -6.39869753e-01 9.94029189e-01 -2.44225201 0.28914394 456.00 -1.14530550e+00 -1.39813693e-01 1.15380785e+00 -3.02011824 0.34350970 456.25 -1.00802036e+00 4.85745219e-01 1.11895195e+00 2.69254554 0.24476340 456.50 -7.82906009e-01 1.21156134e+00 1.44250570e+00 2.14449269 0.40842538 456.75 -2.50339447e-01 1.63049245e+00 1.64959858e+00 1.72314275 0.46821264 457.00 4.47431500e-01 1.97137930e+00 2.02151708e+00 1.34761361 0.65834915 457.25 9.16572322e-01 2.08000479e+00 2.27299906e+00 1.15573768 0.63009602 457.50 1.74240626e+00 1.98827419e+00 2.64371213e+00 0.85120731 0.67686409 457.75 2.11733257e+00 1.52788335e+00 2.61103902e+00 0.62508102 0.69390650 458.00 2.64817924e+00 1.00364222e+00 2.83198711e+00 0.36226705 0.77534003 458.25 2.93106054e+00 3.66781246e-01 2.95392017e+00 0.12448892 0.79405394 458.50 3.15994417e+00 -4.25240690e-01 3.18842858e+00 -0.13376858 0.85308025 458.75 3.21010093e+00 -7.98632861e-01 3.30795442e+00 -0.24383712 0.83588996 459.00 3.25720489e+00 -9.52049751e-01 3.39349118e+00 -0.28436885 0.88197491 459.25 3.07678251e+00 -1.48899382e+00 3.41814178e+00 -0.45072139 0.90530786 459.50 2.92877858e+00 -1.93942881e+00 3.51270951e+00 -0.58490193 0.92577764 459.75 2.82031320e+00 -2.44681497e+00 3.73377423e+00 -0.71460549 0.93369860 460.00 2.73951534e+00 -2.73440909e+00 3.87065077e+00 -0.78446533 0.94094600 460.25 2.32946081e+00 -3.16120156e+00 3.92677769e+00 -0.93573794 0.91607256 460.50 1.96391603e+00 -3.49978306e+00 4.01315931e+00 -1.05943020 0.92418166 460.75 1.41623474e+00 -3.67723210e+00 3.94052747e+00 -1.20316898 0.85119490 461.00 8.10590759e-01 -3.87841657e+00 3.96221813e+00 -1.36476167 0.87978183 461.25 1.11615881e-01 -3.86854139e+00 3.87015124e+00 -1.54195214 0.89625662 461.50 -5.91471502e-02 -3.75960993e+00 3.76007516e+00 -1.58652729 0.88834688 461.75 -1.45756642e+00 -3.93982721e+00 4.20080210e+00 -1.92513837 0.82379781 462.00 -2.07320528e+00 -3.77381031e+00 4.30578964e+00 -2.07315310 0.85047952 462.25 -2.57748323e+00 -2.75525915e+00 3.77291304e+00 -2.32287015 0.83074094 462.50 -2.72350172e+00 -2.21410741e+00 3.50994776e+00 -2.45899699 0.83883716 462.75 -2.70345798e+00 -1.39684940e+00 3.04300399e+00 -2.66468246 0.80142119 463.00 -2.53693541e+00 -1.00029622e+00 2.72701921e+00 -2.76601565 0.79375681 463.25 -2.13749736e+00 -5.88232948e-01 2.21696030e+00 -2.87304326 0.78513578 463.50 -1.99979697e+00 -4.24319943e-01 2.04431782e+00 -2.93251201 0.78652670 463.75 -2.22125399e+00 -3.16013651e-01 2.24362072e+00 -3.00027288 0.75195548 464.00 -2.32682854e+00 -2.33017548e-01 2.33846706e+00 -3.04178159 0.72877085 464.25 -2.45580348e+00 2.90001497e-01 2.47286708e+00 3.02404878 0.77803841 464.50 -2.28596617e+00 6.53453863e-01 2.37752882e+00 2.86316331 0.80073917 464.75 -1.78715023e+00 1.14930079e+00 2.12480546e+00 2.57008950 0.78818168 465.00 -1.53827177e+00 1.48413683e+00 2.13750840e+00 2.37410377 0.79510206 465.25 -1.04087442e+00 1.31190043e+00 1.67466483e+00 2.24150581 0.70910722 465.50 -9.15086392e-01 1.05505140e+00 1.39660895e+00 2.28527039 0.69670357 465.75 -1.01942391e+00 9.52291534e-01 1.39502125e+00 2.39022904 0.76738788 466.00 -9.17346460e-01 8.88502635e-01 1.27709101e+00 2.37216558 0.76635225 466.25 -8.46617680e-01 8.14296183e-01 1.17466581e+00 2.37565210 0.80394685 466.50 -1.00198339e+00 8.12905586e-01 1.29026594e+00 2.46000147 0.78816713 466.75 -1.12596207e+00 9.14627067e-01 1.45063202e+00 2.45939226 0.88170605 467.00 -1.30061329e+00 1.03721913e+00 1.66355597e+00 2.46838735 0.89588273 467.25 -1.43485851e+00 1.39008841e+00 1.99778996e+00 2.37204128 0.92773524 467.50 -1.13002495e+00 1.66799218e+00 2.01473430e+00 2.16624514 0.92999837 467.75 -9.49192423e-01 1.80422882e+00 2.03867797e+00 2.05509990 0.96552671 468.00 -7.76130783e-01 1.89160024e+00 2.04463455e+00 1.96015362 0.94967535 468.25 -5.89525372e-01 2.06368975e+00 2.14624219e+00 1.84905106 0.96397903 468.50 -4.82887197e-01 2.08126850e+00 2.13655297e+00 1.79877840 0.96716415 468.75 -4.01888395e-01 2.07940696e+00 2.11788753e+00 1.76171309 0.97674260 469.00 -3.47303535e-01 2.15055436e+00 2.17841773e+00 1.73090882 0.96209159 469.25 -3.97639111e-01 2.15910397e+00 2.19541495e+00 1.75292407 0.96057852 469.50 -4.85957541e-01 2.28094672e+00 2.33213908e+00 1.78070867 0.94332921 469.75 -6.33786347e-01 2.49237831e+00 2.57169881e+00 1.81980834 0.91069197 470.00 -5.54394603e-01 3.08105174e+00 3.13053242e+00 1.74882805 0.88569740 470.25 -3.02221406e-01 3.65241657e+00 3.66489898e+00 1.65335385 0.93333294 470.50 1.51334209e-01 4.15731020e+00 4.16006372e+00 1.53441044 0.94230742 470.75 5.93872578e-01 4.49382604e+00 4.53289721e+00 1.43940469 0.93768893 471.00 1.54307344e+00 4.43370164e+00 4.69454853e+00 1.23587513 0.92890279 471.25 2.29499692e+00 4.23576861e+00 4.81754571e+00 1.07426000 0.94072188 471.50 3.12388367e+00 4.12400557e+00 5.17359363e+00 0.92252026 0.94229034 471.75 3.31277061e+00 3.84098156e+00 5.07223703e+00 0.85910133 0.94024426 472.00 3.66861386e+00 3.16403049e+00 4.84456568e+00 0.71168306 0.96720415 472.25 3.93601463e+00 2.96193532e+00 4.92597929e+00 0.64511287 0.97591183 472.50 3.89939566e+00 2.47136399e+00 4.61659252e+00 0.56488904 0.96992599 472.75 3.68416982e+00 2.38020834e+00 4.38617134e+00 0.57360306 0.97545895 473.00 3.72754315e+00 2.36045717e+00 4.41206709e+00 0.56450809 0.98002378 473.25 3.76074787e+00 2.23705601e+00 4.37580211e+00 0.53661925 0.97972215 473.50 3.70326419e+00 2.34670664e+00 4.38419864e+00 0.56482105 0.97887601 473.75 3.74186182e+00 2.38112920e+00 4.43523462e+00 0.56671864 0.97454405 474.00 4.22981345e+00 2.36837520e+00 4.84773379e+00 0.51043067 0.96783485 474.25 4.47766447e+00 2.39641935e+00 5.07861249e+00 0.49140486 0.96990945 474.50 4.85528705e+00 2.21477558e+00 5.33657598e+00 0.42796269 0.96052358 474.75 5.12077149e+00 2.08316682e+00 5.52828045e+00 0.38636086 0.95869429 475.00 5.48334379e+00 1.90099262e+00 5.80351894e+00 0.33371847 0.95073598 475.25 5.60967006e+00 1.79988987e+00 5.89134974e+00 0.31047820 0.93156494 475.50 5.92253418e+00 1.43110942e+00 6.09298657e+00 0.23709321 0.93892431 475.75 5.97860452e+00 1.19173536e+00 6.09622385e+00 0.19675448 0.93382575 476.00 6.55200638e+00 8.47462125e-01 6.60658608e+00 0.12862976 0.88252645 476.25 6.93093111e+00 3.22356280e-01 6.93842342e+00 0.04647632 0.84289364 476.50 7.20291679e+00 -1.47958189e+00 7.35331033e+00 -0.20259613 0.87091453 476.75 6.90724202e+00 -1.90472004e+00 7.16505064e+00 -0.26906981 0.88737929 477.00 6.22161243e+00 -2.94086000e+00 6.88165087e+00 -0.44155743 0.85271388 477.25 6.02677156e+00 -3.03293705e+00 6.74690171e+00 -0.46623950 0.85474271 477.50 5.65559903e+00 -3.05840209e+00 6.42958970e+00 -0.49573249 0.88477359 477.75 4.73476767e+00 -3.12555441e+00 5.67336895e+00 -0.58346241 0.88213085 478.00 4.30559677e+00 -3.27416437e+00 5.40909566e+00 -0.65015170 0.94005416 478.25 4.16528581e+00 -3.18740348e+00 5.24491629e+00 -0.65317754 0.93887005 478.50 4.18886411e+00 -2.80689949e+00 5.04234740e+00 -0.59036615 0.94615806 478.75 4.29012434e+00 -2.76178046e+00 5.10221503e+00 -0.57197112 0.95869569 479.00 4.51284877e+00 -2.94441468e+00 5.38844893e+00 -0.57809662 0.96510306 479.25 4.86223666e+00 -3.12690908e+00 5.78090873e+00 -0.57150998 0.96360449 479.50 4.93411441e+00 -3.51557392e+00 6.05844411e+00 -0.61906839 0.97409652 479.75 4.51715632e+00 -3.71700420e+00 5.84985653e+00 -0.68852761 0.96085914 480.00 4.19968752e+00 -4.03968052e+00 5.82721151e+00 -0.76598079 0.97247364 480.25 4.11538085e+00 -3.96830781e+00 5.71697703e+00 -0.76720637 0.95802610 480.50 4.34300006e+00 -3.85665234e+00 5.80821976e+00 -0.72615436 0.96420972 480.75 4.55933010e+00 -3.87722694e+00 5.98501293e+00 -0.70472275 0.95942886 481.00 4.68749699e+00 -4.16229567e+00 6.26875851e+00 -0.72612152 0.96612000 481.25 4.64046126e+00 -5.12294585e+00 6.91219610e+00 -0.83477564 0.94028251 481.50 4.11777693e+00 -5.86959949e+00 7.16995711e+00 -0.95903549 0.92933946 481.75 3.00110656e+00 -6.14574636e+00 6.83935954e+00 -1.11653424 0.87582138 482.00 2.25273739e+00 -5.84170714e+00 6.26101973e+00 -1.20273895 0.85777950 482.25 2.63641974e+00 -4.67735470e+00 5.36920441e+00 -1.05752904 0.84981205 482.50 3.00109161e+00 -4.14871830e+00 5.12039201e+00 -0.94455212 0.89605409 482.75 4.37574806e+00 -3.94510907e+00 5.89160900e+00 -0.73369013 0.86501576 483.00 5.65955703e+00 -3.99318832e+00 6.92648098e+00 -0.61445146 0.83285989 483.25 7.70473652e+00 -5.87317608e+00 9.68799061e+00 -0.65131488 0.78288473 483.50 8.01667593e+00 -8.22913097e+00 1.14885025e+01 -0.79847495 0.75434397 483.75 5.86034327e+00 -1.02146028e+01 1.17763209e+01 -1.04992296 0.71237583 484.00 4.60128013e+00 -9.05361676e+00 1.01557745e+01 -1.10058988 0.46175254 484.25 -7.26029659e+00 -4.48137093e+00 8.53197468e+00 -2.58859049 0.19940813 484.50 -9.27391470e+00 -2.09440889e+00 9.50747298e+00 -2.91948006 0.32814192 484.75 -4.84349648e+00 2.85007335e-01 4.85187462e+00 3.08281712 0.40654359 485.00 -3.91559041e+00 -1.18539326e+00 4.09108854e+00 -2.84762694 0.45164333 485.25 -3.03777273e+00 -3.97769356e+00 5.00500841e+00 -2.22300923 0.60347511 485.50 -3.70762270e+00 -5.36006098e+00 6.51741665e+00 -2.17593872 0.67234167 485.75 -7.57130492e+00 -5.46572159e+00 9.33802820e+00 -2.51631971 0.63029677 486.00 -1.03250351e+01 -2.90712638e+00 1.07264968e+01 -2.86713710 0.65366514 486.25 -1.01075277e+01 2.34981025e+00 1.03770769e+01 2.91316900 0.75975752 486.50 -7.60954059e+00 3.59818025e+00 8.41736355e+00 2.69989902 0.73075576 486.75 -5.17116017e+00 4.47814001e+00 6.84066045e+00 2.42789215 0.81616584 487.00 -4.16387880e+00 4.42510652e+00 6.07613811e+00 2.32578959 0.83445817 487.25 -2.83802474e+00 4.38319025e+00 5.22175653e+00 2.14539745 0.86073577 487.50 -1.92368242e+00 4.49895998e+00 4.89297404e+00 1.97485344 0.87790922 487.75 -9.86315153e-01 4.32194783e+00 4.43306335e+00 1.79516474 0.89900674 488.00 -3.19894559e-01 3.56278101e+00 3.57711351e+00 1.66034408 0.89043048 488.25 -7.93420262e-02 2.91565548e+00 2.91673482e+00 1.59800203 0.92785334 488.50 8.79103210e-02 2.50698852e+00 2.50852939e+00 1.53574458 0.89167037 488.75 3.06051792e-01 2.08476002e+00 2.10710513e+00 1.42503319 0.88264309 489.00 2.02359935e-01 2.01085350e+00 2.02100998e+00 1.47050014 0.76895808 489.25 -1.73060877e-01 2.10644872e+00 2.11354590e+00 1.65276987 0.73078836 489.50 -3.00633715e-01 2.53714439e+00 2.55489379e+00 1.68873933 0.80557599 489.75 -3.39486686e-01 3.09541428e+00 3.11397508e+00 1.68003381 0.85730984 490.00 1.58016668e-01 3.68250815e+00 3.68589684e+00 1.52791257 0.85751910 490.25 7.91418672e-01 3.88357071e+00 3.96339059e+00 1.36976272 0.87471097 490.50 1.48652438e+00 3.92451328e+00 4.19661283e+00 1.20871642 0.89620657 490.75 2.29489166e+00 4.13184530e+00 4.72638057e+00 1.06380472 0.91386739 491.00 3.26766848e+00 3.91626327e+00 5.10046814e+00 0.87543814 0.93409838 491.25 4.00412726e+00 3.61832639e+00 5.39678802e+00 0.73482758 0.95661058 491.50 4.67504267e+00 2.77043905e+00 5.43427608e+00 0.53496194 0.95472330 491.75 5.04271888e+00 2.21060427e+00 5.50597720e+00 0.41314503 0.96801228 492.00 5.16079373e+00 1.27512424e+00 5.31598850e+00 0.24222769 0.96838402 492.25 5.05494310e+00 9.43199456e-01 5.14218581e+00 0.18446826 0.97602030 492.50 5.13251001e+00 4.83428314e-01 5.15522666e+00 0.09391239 0.97146863 492.75 5.10391653e+00 3.08623146e-01 5.11323892e+00 0.06039437 0.98209803 493.00 4.90362294e+00 -1.01003687e-01 4.90466305e+00 -0.02059486 0.97758640 493.25 4.88444017e+00 -4.20939479e-01 4.90254483e+00 -0.08596727 0.98166866 493.50 4.83604792e+00 -6.86077093e-01 4.88447144e+00 -0.14092688 0.98159113 493.75 4.65478306e+00 -8.89769571e-01 4.73906058e+00 -0.18887326 0.98224080 494.00 4.68260714e+00 -1.03060723e+00 4.79468048e+00 -0.21663864 0.97979091 494.25 4.72357234e+00 -1.25430398e+00 4.88727063e+00 -0.25955153 0.97821605 494.50 4.41188057e+00 -1.58349315e+00 4.68744501e+00 -0.34459534 0.98043660 494.75 4.24322332e+00 -1.71503126e+00 4.57671021e+00 -0.38410569 0.98078121 495.00 4.05780831e+00 -2.02191162e+00 4.53364477e+00 -0.46226808 0.97888065 495.25 3.92208545e+00 -2.23216117e+00 4.51279268e+00 -0.51740868 0.97276522 495.50 3.47205479e+00 -2.37005087e+00 4.20384414e+00 -0.59895757 0.97251561 495.75 3.37098116e+00 -2.32520405e+00 4.09512977e+00 -0.60382762 0.96356549 496.00 3.03993964e+00 -2.16022713e+00 3.72931820e+00 -0.61781475 0.94116967 496.25 2.78466153e+00 -2.14541659e+00 3.51527412e+00 -0.65645533 0.93855936 496.50 2.29048522e+00 -1.89457361e+00 2.97249588e+00 -0.69107766 0.93785958 496.75 2.23572471e+00 -1.59918586e+00 2.74879254e+00 -0.62091249 0.91964247 497.00 2.23402869e+00 -1.01388405e+00 2.45333346e+00 -0.42603988 0.88571620 497.25 2.29116912e+00 -7.34645401e-01 2.40606729e+00 -0.31028534 0.89475166 497.50 2.34431521e+00 -3.09273566e-01 2.36462765e+00 -0.13116745 0.90772610 497.75 2.46235037e+00 -1.17621818e-01 2.46515805e+00 -0.04773183 0.91085237 498.00 2.81080230e+00 1.08529862e-01 2.81289678e+00 0.03859253 0.92467293 498.25 3.19399642e+00 2.98928018e-01 3.20795434e+00 0.09331876 0.91137637 498.50 3.66806965e+00 5.76907671e-01 3.71316003e+00 0.15600035 0.94145349 498.75 3.99043051e+00 7.74379642e-01 4.06487386e+00 0.19167675 0.92505649 499.00 4.47942286e+00 8.19508168e-01 4.55377017e+00 0.18094840 0.94071697 499.25 4.58856067e+00 8.67869557e-01 4.66991291e+00 0.18692951 0.93985258 499.50 4.87533812e+00 8.65868479e-01 4.95163104e+00 0.17576896 0.93220834 499.75 5.25460759e+00 9.07742816e-01 5.33243827e+00 0.17106342 0.92259543 500.00 5.58231692e+00 9.35947007e-01 5.66023489e+00 0.16611775 0.93111371 500.25 5.79934978e+00 1.15545404e+00 5.91333509e+00 0.19666329 0.93743467 500.50 5.85759565e+00 1.21922240e+00 5.98313714e+00 0.20521376 0.95036418 500.75 6.15507101e+00 1.34754459e+00 6.30085515e+00 0.21553178 0.92747450 501.00 6.53034833e+00 1.69825732e+00 6.74755713e+00 0.25442066 0.93292015 501.25 6.99645909e+00 2.03621767e+00 7.28674291e+00 0.28321229 0.91935668 501.50 7.64205710e+00 2.14558740e+00 7.93754257e+00 0.27371373 0.94121100 501.75 8.31788437e+00 2.30843249e+00 8.63226858e+00 0.27071346 0.95042929 502.00 8.62500663e+00 2.32403783e+00 8.93263070e+00 0.26320236 0.93957557 502.25 9.46892130e+00 3.41699285e+00 1.00665938e+01 0.34632025 0.92320511 502.50 1.03809975e+01 3.86441359e+00 1.10769491e+01 0.35636492 0.94348346 502.75 1.24044625e+01 4.06970058e+00 1.30550049e+01 0.31701837 0.93226805 503.00 1.39862747e+01 4.05545049e+00 1.45623679e+01 0.28221988 0.95907637 503.25 1.52664936e+01 2.84626091e+00 1.55295534e+01 0.18432223 0.95338049 503.50 1.62245693e+01 2.12198895e+00 1.63627469e+01 0.13005044 0.95578405 503.75 1.72164974e+01 1.05525765e+00 1.72488073e+01 0.06121681 0.94148399 504.00 1.74596256e+01 9.84938598e-01 1.74873849e+01 0.05635263 0.94628014 504.25 1.72160260e+01 7.88927182e-01 1.72340929e+01 0.04579313 0.96761731 504.50 1.76557892e+01 8.37141152e-01 1.76756244e+01 0.04737906 0.95991460 504.75 1.95953097e+01 1.71580978e+00 1.96702864e+01 0.08733951 0.92023031 505.00 2.05053276e+01 1.96869108e+00 2.05996166e+01 0.09571539 0.91774271 505.25 2.26999898e+01 2.42749832e+00 2.28294170e+01 0.10653343 0.90117443 505.50 2.38584716e+01 3.64653724e+00 2.41355319e+01 0.15166664 0.89581124 505.75 2.40529028e+01 1.65700248e+00 2.41099106e+01 0.06878125 0.87265374 506.00 2.43586016e+01 2.64067919e-01 2.43600329e+01 0.01084042 0.84199090 506.25 2.07751426e+01 -1.64504938e+00 2.08401713e+01 -0.07901867 0.77733429 506.50 1.77759881e+01 2.29173728e-01 1.77774654e+01 0.01289161 0.75821142 506.75 1.44997619e+01 4.00899332e+00 1.50437736e+01 0.26974799 0.76591586 507.00 1.28491664e+01 7.78375172e+00 1.50229115e+01 0.54465774 0.73323240 507.25 9.68843271e+00 1.42276011e+01 1.72130869e+01 0.97296324 0.75353301 507.50 6.79229493e+00 1.69851405e+01 1.82929021e+01 1.19037934 0.70275998 507.75 2.71478877e+00 2.01951374e+01 2.03767921e+01 1.43716956 0.69001081 508.00 6.81016972e-01 1.91529022e+01 1.91650057e+01 1.53525444 0.68733246 508.25 -1.75689736e+00 1.67049480e+01 1.67970823e+01 1.67558338 0.71834780 508.50 -3.70748541e+00 1.55102701e+01 1.59472232e+01 1.80542793 0.71447190 508.75 -7.90640834e+00 1.33408442e+01 1.55077212e+01 2.10579150 0.74524920 509.00 -9.94375240e+00 1.03469903e+01 1.43505547e+01 2.33632411 0.73371074 509.25 -1.11978721e+01 5.43499349e+00 1.24471480e+01 2.68972590 0.71598377 509.50 -1.23340774e+01 3.01358834e+00 1.26968965e+01 2.90195729 0.72798331 509.75 -1.34608963e+01 1.82947687e+00 1.35846500e+01 3.00650985 0.79696798 510.00 -1.30380592e+01 -3.27940062e-01 1.30421828e+01 -3.11644543 0.79985094 510.25 -1.14703778e+01 -4.21333439e+00 1.22197281e+01 -2.78956937 0.82833108 510.50 -9.51583059e+00 -5.42466506e+00 1.09534480e+01 -2.62347323 0.75961095 510.75 -6.77033772e+00 -7.03107872e+00 9.76081661e+00 -2.33730440 0.67957541 511.00 -3.14717931e+00 -7.68769674e+00 8.30695003e+00 -1.95936155 0.37081090 511.25 -1.39970091e+00 -8.04680844e+00 8.16763667e+00 -1.74301802 0.26244707 511.50 -3.05788081e+00 -9.09669391e+00 9.59689925e+00 -1.89508242 0.18483228 511.75 -4.01627987e+00 -1.30401455e+01 1.36446290e+01 -1.86957036 0.26713795 512.00 1.42958555e+00 -1.19653661e+01 1.20504648e+01 -1.45188305 0.16900048 512.25 1.18244368e+00 -6.75696401e+00 6.85964545e+00 -1.39755425 0.05681105 512.50 1.88145793e+00 -1.00535171e+01 1.02280541e+01 -1.38579207 0.09361574 512.75 6.06666741e+00 -1.19071319e+01 1.33635416e+01 -1.09957872 0.13568387 513.00 9.72222606e+00 -1.31996220e+01 1.63936481e+01 -0.93595675 0.24852633 513.25 1.13138810e+01 -1.66915450e+01 2.01646121e+01 -0.97511114 0.28567639 513.50 7.50984200e+00 -1.52079806e+01 1.69611439e+01 -1.11211355 0.22058071 513.75 7.31755551e+00 -1.46657562e+01 1.63899671e+01 -1.10798490 0.23615221 514.00 6.08917153e+00 -2.11845469e+01 2.20423011e+01 -1.29090692 0.66570924 514.25 6.84271515e+00 -1.88005233e+01 2.00070594e+01 -1.22173591 0.70896236 514.50 6.71452857e+00 -1.34720223e+01 1.50525838e+01 -1.10842522 0.70858329 514.75 5.87765584e+00 -1.30927608e+01 1.43515582e+01 -1.14883748 0.82720116 515.00 4.93766755e+00 -1.03867722e+01 1.15006782e+01 -1.12703769 0.82937095 515.25 4.23011033e+00 -8.58290053e+00 9.56869975e+00 -1.11288245 0.84027073 515.50 3.01545263e+00 -6.73666293e+00 7.38075755e+00 -1.14992491 0.89286211 515.75 2.58865473e+00 -5.95270404e+00 6.49121088e+00 -1.16059516 0.89801326 516.00 1.92342833e+00 -4.65927874e+00 5.04068000e+00 -1.17929008 0.89777173 516.25 1.87136187e+00 -4.22943747e+00 4.62494720e+00 -1.15422935 0.89078499 516.50 1.33831447e+00 -3.71369444e+00 3.94748173e+00 -1.22491076 0.85160781 516.75 9.25941092e-01 -3.56691488e+00 3.68513889e+00 -1.31681086 0.87823510 517.00 2.50737202e-01 -3.17099039e+00 3.18088812e+00 -1.49188830 0.87885914 517.25 -2.34551400e-01 -3.01019864e+00 3.01932280e+00 -1.64855812 0.84970072 517.50 -8.12779015e-01 -2.43479467e+00 2.56687257e+00 -1.89298329 0.83857562 517.75 -1.18368815e+00 -1.97689357e+00 2.30417574e+00 -2.11030481 0.80428761 518.00 -1.75773499e+00 -1.23813036e+00 2.15002304e+00 -2.52792668 0.83717522 518.25 -1.90368455e+00 -5.35424294e-01 1.97754749e+00 -2.86741887 0.72670532 518.50 -1.68050463e+00 3.92794514e-01 1.72579933e+00 2.91197883 0.73929670 518.75 -1.27719976e+00 6.47308923e-01 1.43186874e+00 2.67250485 0.53811084 519.00 -6.68753516e-01 9.99207016e-01 1.20235017e+00 2.16060891 0.52008175 519.25 -5.08805499e-01 8.07594697e-01 9.54511514e-01 2.13300154 0.42957517 519.50 -3.86157431e-01 5.34285896e-01 6.59226046e-01 2.19663096 0.32608534 519.75 -4.34491034e-01 5.00831108e-01 6.63034130e-01 2.28538556 0.29380014 520.00 -4.95362411e-01 6.23575364e-01 7.96385681e-01 2.24210753 0.50414391 520.25 -5.46740494e-01 5.77351778e-01 7.95147938e-01 2.32896922 0.54586366 520.50 -5.87897402e-01 6.37648585e-01 8.67305640e-01 2.31562165 0.67282883 520.75 -6.48612164e-01 6.96130022e-01 9.51469783e-01 2.32087315 0.71122911 521.00 -6.16606115e-01 6.98118561e-01 9.31435788e-01 2.29427412 0.73375173 521.25 -7.19345082e-01 7.62294132e-01 1.04811721e+00 2.32721508 0.74726571 521.50 -8.75484054e-01 9.14224992e-01 1.26581186e+00 2.33455137 0.85706298 521.75 -8.79493846e-01 1.06940692e+00 1.38460846e+00 2.25905494 0.86245949 522.00 -8.42679648e-01 1.20583964e+00 1.47110782e+00 2.18073815 0.89746297 522.25 -6.11541751e-01 1.39923825e+00 1.52703995e+00 1.98283180 0.82849507 522.50 -3.98268068e-01 1.54607002e+00 1.59654313e+00 1.82291530 0.86016583 522.75 -2.47638313e-01 1.59509760e+00 1.61420602e+00 1.72481639 0.89742902 523.00 -1.37390480e-01 1.59388503e+00 1.59979550e+00 1.65678227 0.92275495 523.25 1.01152794e-01 1.49103517e+00 1.49446236e+00 1.50305947 0.84417198 523.50 3.22924196e-01 1.36737856e+00 1.40499259e+00 1.33888254 0.84614604 523.75 5.15736597e-01 1.05035058e+00 1.17013699e+00 1.11436351 0.72493049 524.00 5.92242249e-01 7.87388631e-01 9.85257193e-01 0.92591424 0.70738011 524.25 5.34862535e-01 5.93659132e-01 7.99067642e-01 0.83745165 0.57882657 524.50 4.07923119e-01 3.91698236e-01 5.65534066e-01 0.76511024 0.37271576 524.75 5.24606763e-02 3.59169068e-01 3.62980085e-01 1.42576068 0.21279014 525.00 -2.65632473e-02 2.71660240e-01 2.72955843e-01 1.66826761 0.17471774 525.25 -1.90628120e-01 2.27835671e-01 2.97065941e-01 2.26751307 0.19296359 525.50 -2.99057281e-01 2.53940322e-01 3.92327598e-01 2.43760036 0.28701927 525.75 -4.49120351e-01 4.14221584e-01 6.10973494e-01 2.39659537 0.49258009 526.00 -4.71950232e-01 5.11420720e-01 6.95908165e-01 2.31607808 0.54423511 526.25 -4.52813219e-01 6.64738870e-01 8.04311865e-01 2.16878601 0.68336840 526.50 -3.51501169e-01 7.42918732e-01 8.21876703e-01 2.01272224 0.69311563 526.75 -1.66471778e-01 8.29765895e-01 8.46300357e-01 1.76879277 0.71088476 527.00 -1.01948034e-01 8.62909289e-01 8.68910722e-01 1.68839575 0.76071313 527.25 1.19675307e-01 7.10315410e-01 7.20326427e-01 1.40388197 0.72937820 527.50 2.23999367e-01 6.20799657e-01 6.59975705e-01 1.22451154 0.74891653 527.75 2.58737328e-01 5.25334230e-01 5.85594619e-01 1.11315104 0.76235354 528.00 2.60627270e-01 4.48878390e-01 5.19055279e-01 1.04474956 0.68409137 528.25 2.06107971e-01 2.82075066e-01 3.49352027e-01 0.93977196 0.53745310 528.50 1.46623213e-01 2.36719647e-01 2.78450279e-01 1.01623697 0.43890171 528.75 1.32073573e-01 1.64035529e-01 2.10596970e-01 0.89292166 0.41996021 529.00 1.33710135e-01 1.38972044e-01 1.92851313e-01 0.80469263 0.36894508 529.25 1.13086582e-01 1.70171061e-01 2.04320251e-01 0.98426297 0.37635500 529.50 1.50109737e-01 1.87716609e-01 2.40354859e-01 0.89626185 0.43359086 529.75 1.74939473e-01 1.14997850e-01 2.09352155e-01 0.58153038 0.49226001 530.00 1.86631614e-01 4.85831330e-02 1.92851446e-01 0.25466371 0.39228559 530.25 1.98800873e-01 -8.49921831e-03 1.98982471e-01 -0.04272640 0.53088818 530.50 1.99368819e-01 -6.97801811e-02 2.11227838e-01 -0.33667971 0.52599979 530.75 1.79168152e-01 -1.17494812e-01 2.14257457e-01 -0.58042746 0.60664726 531.00 1.59178646e-01 -1.21204900e-01 2.00071160e-01 -0.65078225 0.54455071 531.25 1.73234380e-01 -1.31695947e-01 2.17609680e-01 -0.65000881 0.67504941 531.50 2.09578359e-01 -1.47874051e-01 2.56495271e-01 -0.61446033 0.67275790 531.75 2.65456405e-01 -1.77295504e-01 3.19219045e-01 -0.58884859 0.75360115 532.00 3.09072706e-01 -2.18778565e-01 3.78668718e-01 -0.61597814 0.78296754 532.25 3.37078191e-01 -2.52895597e-01 4.21399916e-01 -0.64366619 0.83045156 532.50 4.49772146e-01 -3.58348592e-01 5.75072775e-01 -0.67274607 0.84851547 532.75 5.21736598e-01 -4.63153854e-01 6.97653618e-01 -0.72598668 0.92162599 533.00 5.52862540e-01 -6.55195673e-01 8.57285459e-01 -0.86990520 0.92713719 533.25 5.47078461e-01 -8.07267664e-01 9.75179945e-01 -0.97519991 0.94751264 533.50 4.76317567e-01 -1.06316323e+00 1.16498690e+00 -1.14959083 0.93768221 533.75 4.28988063e-01 -1.19154524e+00 1.26641653e+00 -1.22521714 0.95933604 534.00 2.58962115e-01 -1.45004860e+00 1.47299095e+00 -1.39407085 0.95744895 534.25 1.71006059e-01 -1.59974503e+00 1.60885898e+00 -1.46430489 0.96574974 534.50 -1.17815609e-01 -1.85411476e+00 1.85785415e+00 -1.63425379 0.95474861 534.75 -2.27600790e-01 -1.97685736e+00 1.98991636e+00 -1.68542425 0.96350026 535.00 -6.59034437e-01 -2.09338034e+00 2.19466801e+00 -1.87579184 0.95052851 535.25 -9.03071084e-01 -2.12066604e+00 2.30494291e+00 -1.97338090 0.96615498 535.50 -1.22777212e+00 -2.11687111e+00 2.44715502e+00 -2.09637548 0.95675573 535.75 -1.45572977e+00 -2.09829862e+00 2.55382189e+00 -2.17732662 0.95221472 536.00 -1.97726474e+00 -1.77647024e+00 2.65808622e+00 -2.40963548 0.93842048 536.25 -2.05219193e+00 -1.53221366e+00 2.56108774e+00 -2.50025634 0.94574295 536.50 -2.13877330e+00 -1.18880546e+00 2.44695927e+00 -2.63428049 0.94329314 536.75 -2.14899681e+00 -1.09748386e+00 2.41301846e+00 -2.66942498 0.93803181 537.00 -2.27999763e+00 -1.01786757e+00 2.49688677e+00 -2.72170850 0.91371437 537.25 -2.44207816e+00 -9.99600881e-01 2.63873979e+00 -2.75307439 0.90411840 537.50 -2.59540622e+00 -8.89777401e-01 2.74369045e+00 -2.81132156 0.87019656 537.75 -2.59039201e+00 -8.36985736e-01 2.72225566e+00 -2.82906968 0.75639291 538.00 -2.51950447e+00 -4.75563225e-01 2.56399360e+00 -2.95503484 0.46667371 538.25 -2.29988297e+00 -2.60181784e-01 2.31455314e+00 -3.02894332 0.31403943 538.50 -1.14629250e+00 1.28525142e+00 1.72216657e+00 2.29910815 0.15547371 538.75 -7.53693709e-01 1.42750622e+00 1.61425779e+00 2.05657601 0.19572840 539.00 -5.11548132e-01 2.09311822e+00 2.15472164e+00 1.81049301 0.48864418 539.25 -3.87901180e-01 2.75094050e+00 2.77815424e+00 1.71087953 0.67705278 539.50 4.09228386e-02 3.25564697e+00 3.25590416e+00 1.55822719 0.81172761 539.75 6.77354754e-01 2.78061054e+00 2.86192321e+00 1.33185087 0.69838280 540.00 1.62540932e+00 2.03595002e+00 2.60519634e+00 0.89705971 0.81426421 540.25 1.81166778e+00 1.59638828e+00 2.41466265e+00 0.72231415 0.78579795 540.50 2.06978111e+00 1.01304247e+00 2.30439773e+00 0.45516741 0.83424425 540.75 1.98493526e+00 4.75153737e-01 2.04101423e+00 0.23495863 0.79545599 541.00 1.90915640e+00 -1.52890659e-02 1.90921762e+00 -0.00800811 0.82257687 541.25 1.60260379e+00 -3.27722534e-01 1.63576923e+00 -0.20171276 0.76893028 541.50 1.42077160e+00 -5.47174345e-01 1.52249522e+00 -0.36761751 0.75023879 541.75 1.32437862e+00 -7.09579266e-01 1.50249175e+00 -0.49186240 0.72543362 542.00 1.17494295e+00 -9.02176998e-01 1.48135555e+00 -0.65482600 0.68949756 542.25 1.05568564e+00 -1.01502829e+00 1.46449807e+00 -0.76576623 0.63200604 542.50 9.88141069e-01 -1.16310074e+00 1.52618023e+00 -0.86654917 0.54371968 542.75 4.44466278e-01 -1.95394739e+00 2.00386144e+00 -1.34713124 0.63126652 543.00 -2.11301379e-01 -2.01011402e+00 2.02118942e+00 -1.67553078 0.57334652 543.25 -8.71952243e-01 -1.02940961e+00 1.34906815e+00 -2.27357008 0.48204595 543.50 -6.78570232e-01 -7.86198046e-01 1.03853981e+00 -2.28284859 0.39228721 543.75 -4.72501439e-01 -1.11845240e+00 1.21416366e+00 -1.97051363 0.55874942 544.00 -5.54535736e-01 -1.15489495e+00 1.28112928e+00 -2.01844730 0.71835341 544.25 -6.86738413e-01 -1.12141986e+00 1.31498751e+00 -2.12027122 0.70653760 544.50 -7.05096377e-01 -1.13114687e+00 1.33291191e+00 -2.12820568 0.73053607 544.75 -8.00508836e-01 -1.01501606e+00 1.29269950e+00 -2.23858809 0.82718592 545.00 -8.06186468e-01 -1.02623155e+00 1.30502406e+00 -2.23668222 0.83901122 545.25 -1.01404319e+00 -9.81590424e-01 1.41131264e+00 -2.37245494 0.81634924 545.50 -1.21116597e+00 -9.97216431e-01 1.56887336e+00 -2.45277374 0.83984310 545.75 -1.42935075e+00 -9.13443496e-01 1.69629673e+00 -2.57294531 0.82978680 546.00 -1.48952673e+00 -7.89537912e-01 1.68584103e+00 -2.65418756 0.78861471 546.25 -1.97474472e+00 -2.33514649e-01 1.98850341e+00 -3.02388870 0.76498178 546.50 -2.03836228e+00 1.51971376e-01 2.04401959e+00 3.06717471 0.75472880 546.75 -1.73044732e+00 8.32356689e-01 1.92022540e+00 2.69325484 0.71478190 547.00 -1.39233035e+00 1.05177432e+00 1.74493926e+00 2.49464085 0.67438601 547.25 -7.47316533e-01 9.98941924e-01 1.24754438e+00 2.21308551 0.54738237 547.50 -3.54989881e-01 6.65737611e-01 7.54469603e-01 2.06067158 0.25403884 547.75 -3.74210865e-02 3.47354357e-01 3.49364261e-01 1.67811415 0.04199063 548.00 -3.27393940e-01 1.87045004e-01 3.77057854e-01 2.62253231 0.03524353 548.25 -4.94428151e-01 -4.94608388e-01 6.99354455e-01 -2.35601226 0.08610616 548.50 -5.61020555e-01 -5.59743153e-01 7.92500133e-01 -2.35733425 0.08196259 548.75 -1.54627340e+00 -1.00362963e+00 1.84342992e+00 -2.56587606 0.19883854 549.00 -1.50376358e+00 -3.82605796e-01 1.55167396e+00 -2.89244693 0.11860760 549.25 -2.25289446e+00 9.92513082e-01 2.46183177e+00 2.72662492 0.23651116 549.50 -2.82266526e+00 1.96534635e+00 3.43948040e+00 2.53337224 0.38854548 549.75 -2.56829719e+00 3.77610897e+00 4.56674385e+00 2.16807133 0.60295883 550.00 -8.07610986e-01 4.67974623e+00 4.74892202e+00 1.74168887 0.65406576 550.25 2.34033633e-01 4.82383055e+00 4.82950442e+00 1.52231820 0.77272799 550.50 1.09327986e+00 4.86427655e+00 4.98562406e+00 1.34971326 0.80952183 550.75 1.88381937e+00 4.79341542e+00 5.15030162e+00 1.19633768 0.87938699 551.00 2.57979464e+00 4.48592862e+00 5.17483294e+00 1.04889744 0.85884154 551.25 3.38135579e+00 4.22832019e+00 5.41407967e+00 0.89624293 0.91227035 551.50 3.72573668e+00 4.15008236e+00 5.57712268e+00 0.83922568 0.89900464 551.75 4.30522918e+00 3.76467724e+00 5.71907274e+00 0.71851441 0.90247547 552.00 4.90083787e+00 3.35096646e+00 5.93693423e+00 0.59973905 0.89626553 552.25 6.37091938e+00 2.80372637e+00 6.96056717e+00 0.41457550 0.90182450 552.50 7.37572353e+00 2.16145097e+00 7.68590710e+00 0.28506791 0.91756789 552.75 7.87447399e+00 8.34686092e-01 7.91858836e+00 0.10560463 0.90350116 553.00 8.37739653e+00 -9.95986316e-01 8.43639505e+00 -0.11833426 0.90525669 553.25 8.35674971e+00 -2.27739993e+00 8.66151350e+00 -0.26606118 0.90871761 553.50 7.89680075e+00 -3.87920537e+00 8.79816438e+00 -0.45661314 0.92523877 553.75 7.27049474e+00 -4.94929048e+00 8.79520153e+00 -0.59768005 0.94392731 554.00 6.71018119e+00 -4.93024699e+00 8.32669604e+00 -0.63366378 0.92956031 554.25 6.12196267e+00 -4.62534583e+00 7.67282549e+00 -0.64703294 0.93248803 554.50 5.64909029e+00 -4.48900978e+00 7.21549928e+00 -0.67146590 0.91082696 554.75 5.53942558e+00 -5.00521262e+00 7.46574773e+00 -0.73477939 0.91445549 555.00 5.29636488e+00 -5.35590587e+00 7.53241054e+00 -0.79098762 0.90965988 555.25 4.92798721e+00 -5.44216395e+00 7.34181220e+00 -0.83493997 0.88507323 555.50 5.54062483e+00 -6.49204352e+00 8.53493717e+00 -0.86430363 0.87574511 555.75 5.92173387e+00 -7.18855666e+00 9.31355351e+00 -0.88172722 0.91869181 556.00 5.70631458e+00 -8.24277600e+00 1.00252373e+01 -0.96526992 0.90475835 556.25 5.62831438e+00 -9.39687700e+00 1.09535026e+01 -1.03114494 0.89082674 556.50 4.24983862e+00 -1.15345569e+01 1.22925640e+01 -1.21778571 0.87064990 556.75 2.84025215e+00 -1.31687892e+01 1.34716013e+01 -1.35836974 0.82209947 557.00 -1.06109222e+00 -1.51107980e+01 1.51480075e+01 -1.64090204 0.84944056 557.25 -2.77219113e+00 -1.50648195e+01 1.53177619e+01 -1.75277799 0.86234177 557.50 -6.63753933e+00 -1.43993947e+01 1.58555825e+01 -2.00272679 0.84422538 557.75 -8.48668848e+00 -1.28881973e+01 1.54314455e+01 -2.15311350 0.82882435 558.00 -9.27160344e+00 -7.87288343e+00 1.21632612e+01 -2.43759845 0.80003714 558.25 -9.33568179e+00 -6.39154384e+00 1.13140084e+01 -2.54125269 0.79496370 558.50 -8.43954613e+00 -3.74152868e+00 9.23173741e+00 -2.72429688 0.76414742 558.75 -8.21994616e+00 -3.10777221e+00 8.78781901e+00 -2.78012711 0.80360678 559.00 -8.29428295e+00 -2.71678899e+00 8.72789047e+00 -2.82505647 0.85588803 559.25 -7.73013255e+00 -2.26762198e+00 8.05587107e+00 -2.85624937 0.83981660 559.50 -7.75061849e+00 -1.85932852e+00 7.97052003e+00 -2.90614770 0.81590567 559.75 -7.37958627e+00 -1.25705013e+00 7.48588462e+00 -2.97287056 0.80675942 560.00 -6.77582179e+00 -1.18175164e+00 6.87810278e+00 -2.96892230 0.79924370 560.25 -5.93007053e+00 -9.16908914e-01 6.00053818e+00 -2.98818723 0.68296137 560.50 -4.85000745e+00 -1.20189120e+00 4.99671040e+00 -2.89867412 0.53686054 560.75 -4.73112052e+00 -1.57154914e+00 4.98530521e+00 -2.82088702 0.57627586 561.00 -5.24227345e+00 -1.04038722e+00 5.34451462e+00 -2.94567727 0.61926584 561.25 -5.53672996e+00 -1.09309977e+00 5.64360220e+00 -2.94667239 0.59975679 561.50 -7.28506696e+00 -1.83070109e+00 7.51156888e+00 -2.89539551 0.59203371 561.75 -7.61185747e+00 -8.47290949e-01 7.65886911e+00 -3.03073701 0.52156853 562.00 -7.76038444e+00 1.97648885e+00 8.00812555e+00 2.89220519 0.48797135 562.25 -6.76038119e+00 4.55511630e+00 8.15179970e+00 2.54867074 0.47584320 562.50 -5.15802732e+00 5.90755877e+00 7.84248025e+00 2.28856244 0.57337761 562.75 -3.40777866e+00 5.20729710e+00 6.22325465e+00 2.15027507 0.55639954 563.00 -2.23578029e+00 5.21331226e+00 5.67250723e+00 1.97593175 0.60972291 563.25 -7.33789799e-01 4.47517851e+00 4.53493883e+00 1.73331894 0.62207234 563.50 -1.03933923e-01 3.93840054e+00 3.93977170e+00 1.59718008 0.66703602 563.75 6.08417008e-02 2.89767245e+00 2.89831112e+00 1.54980266 0.49265527 564.00 9.31987724e-01 2.52571054e+00 2.69217660e+00 1.21729609 0.47812188 564.25 9.27022852e-01 1.69689801e+00 1.93360653e+00 1.07079485 0.27670133 564.50 6.57755989e-01 6.25809919e-01 9.07899221e-01 0.76051477 0.08959959 564.75 4.67175832e-01 -4.00245788e-01 6.15182858e-01 -0.70839098 0.06042647 565.00 1.57002322e-01 -1.05335138e+00 1.06498773e+00 -1.42283533 0.17262569 565.25 -6.72984329e-01 -1.02734492e+00 1.22814718e+00 -2.15072846 0.21460263 565.50 -6.26991300e-01 -7.32695613e-01 9.64344830e-01 -2.27860889 0.14320455 565.75 -5.13303276e-01 -1.09611117e+00 1.21034703e+00 -2.00875971 0.18883843 566.00 -3.96047750e-01 -1.50445565e+00 1.55571225e+00 -1.82820606 0.27272065 566.25 9.41304936e-02 -2.70545220e+00 2.70708924e+00 -1.53601747 0.48727996 566.50 1.60251853e-01 -3.35781397e+00 3.36163581e+00 -1.52310746 0.55413378 566.75 -2.11419289e+00 -5.34504301e+00 5.74798194e+00 -1.94745433 0.76154814 567.00 -2.90373906e+00 -5.78743431e+00 6.47503640e+00 -2.03582831 0.84610587 567.25 -5.71941993e+00 -5.95645811e+00 8.25779375e+00 -2.33589575 0.90525914 567.50 -6.82614584e+00 -5.56469410e+00 8.80693406e+00 -2.45765013 0.91218210 567.75 -8.67118876e+00 -4.08978717e+00 9.58727665e+00 -2.70087918 0.92119832 568.00 -9.44300055e+00 -3.04703265e+00 9.92243253e+00 -2.82946388 0.93902742 568.25 -1.02832764e+01 -1.14793750e+00 1.03471510e+01 -3.03042143 0.95662785 568.50 -1.06454010e+01 -3.07744000e-01 1.06498483e+01 -3.11269207 0.95844356 568.75 -1.04596420e+01 7.49250583e-01 1.04864430e+01 3.07008227 0.95128169 569.00 -1.04288477e+01 1.67545587e+00 1.05625763e+01 2.98229793 0.94732341 569.25 -1.05307213e+01 2.86372823e+00 1.09131586e+01 2.87607318 0.96267136 569.50 -1.03885100e+01 3.04199818e+00 1.08247352e+01 2.85673289 0.95971878 569.75 -1.09016508e+01 3.92879932e+00 1.15879875e+01 2.79569565 0.95443719 570.00 -1.10021219e+01 5.11191132e+00 1.21317074e+01 2.70663959 0.93896352 570.25 -1.07923561e+01 7.39571431e+00 1.30832542e+01 2.54081886 0.94587394 570.50 -9.93077487e+00 8.52746749e+00 1.30896139e+01 2.43207458 0.94265482 570.75 -7.52713675e+00 1.02017862e+01 1.26781004e+01 2.20646004 0.92152581 571.00 -5.99847897e+00 1.03403769e+01 1.19542940e+01 2.09645685 0.89847096 571.25 -5.06467476e+00 1.01909388e+01 1.13800775e+01 2.03202360 0.89599632 571.50 -4.56872852e+00 1.00706398e+01 1.10585291e+01 1.99669650 0.84944212 571.75 -3.79459667e+00 9.98778232e+00 1.06843231e+01 1.93387679 0.87468230 572.00 -4.03938958e+00 1.01527682e+01 1.09268188e+01 1.94945730 0.89785779 572.25 -4.05919575e+00 1.04017736e+01 1.11657496e+01 1.94286134 0.89532627 572.50 -4.74922385e+00 1.12416480e+01 1.22036788e+01 1.97051944 0.90860603 572.75 -4.08378828e+00 1.19094136e+01 1.25901334e+01 1.90113581 0.91616817 573.00 -2.29582376e+00 1.38267316e+01 1.40160377e+01 1.73533755 0.89206716 573.25 -1.07095765e+00 1.55256538e+01 1.55625472e+01 1.63966711 0.92428222 573.50 2.35503489e-01 1.48917935e+01 1.48936555e+01 1.55498333 0.90495369 573.75 5.07325981e-01 1.59495952e+01 1.59576617e+01 1.53899897 0.90459153 574.00 1.09202263e+00 1.71228410e+01 1.71576280e+01 1.50710680 0.88283550 574.25 2.57636674e+00 1.86297284e+01 1.88070318e+01 1.43337466 0.89580225 574.50 5.57486745e+00 1.93782985e+01 2.01642654e+01 1.29067461 0.85016836 574.75 9.54576125e+00 1.95057204e+01 2.17162309e+01 1.11567861 0.85065954 575.00 1.33462679e+01 2.09429484e+01 2.48340483e+01 1.00342378 0.87256694 575.25 1.65701685e+01 2.10147630e+01 2.67617403e+01 0.90310620 0.90805795 575.50 2.00318453e+01 1.80275057e+01 2.69493189e+01 0.73278324 0.85640450 575.75 2.47031796e+01 1.59464695e+01 2.94030095e+01 0.57322147 0.86061965 576.00 2.77305378e+01 9.58874932e+00 2.93415548e+01 0.33291312 0.80605510 576.25 3.04240095e+01 5.44996033e+00 3.09082905e+01 0.17725354 0.81621464 576.50 3.41938248e+01 -2.27533286e+00 3.42694440e+01 -0.06644426 0.78108022 576.75 3.33602826e+01 -1.07416355e+01 3.50469854e+01 -0.31150591 0.80744092 577.00 2.37102478e+01 -2.09163074e+01 3.16175231e+01 -0.72287264 0.76301080 577.25 1.60225579e+01 -2.37197738e+01 2.86242909e+01 -0.97670757 0.78503424 577.50 9.43994586e+00 -2.12891767e+01 2.32882292e+01 -1.15343175 0.80741830 577.75 5.08150066e+00 -1.96547574e+01 2.03010132e+01 -1.31779823 0.83419953 578.00 2.38243006e+00 -1.73640096e+01 1.75266882e+01 -1.43444264 0.91838005 578.25 2.02651882e+00 -1.61995972e+01 1.63258607e+01 -1.44634596 0.94447339 578.50 1.73721877e+00 -1.45936484e+01 1.46966834e+01 -1.45231450 0.96466839 578.75 1.36824788e+00 -1.40300914e+01 1.40966509e+01 -1.47358136 0.96356468 579.00 4.68249635e-01 -1.35120663e+01 1.35201773e+01 -1.53615600 0.95260589 579.25 -2.58356488e-01 -1.30906862e+01 1.30932354e+01 -1.59052967 0.95188597 579.50 -1.33797238e+00 -1.30283965e+01 1.30969189e+01 -1.67313419 0.97012275 579.75 -2.13291075e+00 -1.27288810e+01 1.29063441e+01 -1.73681861 0.96521786 580.00 -3.10837166e+00 -1.18400768e+01 1.22412987e+01 -1.82753243 0.97227847 580.25 -3.73031771e+00 -1.08377464e+01 1.14617633e+01 -1.90229194 0.95697267 580.50 -5.48299848e+00 -9.94411515e+00 1.13555580e+01 -2.07469937 0.96364497 580.75 -6.16154862e+00 -9.15038117e+00 1.10315075e+01 -2.16342208 0.95820549 581.00 -7.15081551e+00 -7.24856821e+00 1.01821365e+01 -2.34940592 0.96570706 581.25 -7.23678668e+00 -6.05816692e+00 9.43782115e+00 -2.44461500 0.95624234 581.50 -7.24391134e+00 -4.11805957e+00 8.33262660e+00 -2.62466787 0.96475100 581.75 -6.65595639e+00 -2.92175667e+00 7.26900389e+00 -2.72795011 0.95377680 582.00 -5.55011732e+00 -1.77261042e+00 5.82631530e+00 -2.83244994 0.94586115 582.25 -4.52868034e+00 -1.56233689e+00 4.79059935e+00 -2.80939051 0.90137527 582.50 -3.72011719e+00 -1.42559289e+00 3.98391604e+00 -2.77564208 0.93163331 582.75 -3.51165728e+00 -1.46550966e+00 3.80518796e+00 -2.74623895 0.93690136 583.00 -3.38705783e+00 -1.47534682e+00 3.69442945e+00 -2.73079187 0.94398235 583.25 -3.56553597e+00 -1.55671372e+00 3.89055322e+00 -2.72993770 0.94803490 583.50 -3.69982412e+00 -1.56079340e+00 4.01556653e+00 -2.74238792 0.96448082 583.75 -4.02341441e+00 -1.41801152e+00 4.26598409e+00 -2.80274592 0.94494347 584.00 -4.22104140e+00 -1.16925889e+00 4.37999507e+00 -2.87136132 0.95349066 584.25 -4.47325172e+00 -6.67498611e-01 4.52277960e+00 -2.99346563 0.92266999 584.50 -4.49433867e+00 -1.43762878e-01 4.49663739e+00 -3.10961601 0.94296378 584.75 -4.24138601e+00 5.05511067e-01 4.27140453e+00 3.02296689 0.90796856 585.00 -4.27178152e+00 1.14607044e+00 4.42284917e+00 2.87947659 0.91862042 585.25 -4.13568458e+00 1.85871065e+00 4.53416941e+00 2.71921084 0.87011338 585.50 -3.61256097e+00 2.47827057e+00 4.38091563e+00 2.54031447 0.85647597 585.75 -2.61943126e+00 2.61418859e+00 3.70072994e+00 2.35719622 0.75966315 586.00 -1.89421556e+00 2.52269479e+00 3.15468566e+00 2.21485393 0.61234128 586.25 -1.18563954e+00 1.95479856e+00 2.28625864e+00 2.11600181 0.49021549 586.50 -1.37424203e+00 1.48850787e+00 2.02588174e+00 2.31630095 0.42884812 586.75 -2.13346627e+00 1.38520292e+00 2.54371096e+00 2.56572839 0.37184981 587.00 -2.49315025e+00 1.98275370e+00 3.18545294e+00 2.46973610 0.48287278 587.25 -3.67328971e+00 3.63739298e+00 5.16949562e+00 2.36110463 0.66591253 587.50 -3.20368589e+00 4.27560523e+00 5.34269626e+00 2.21384552 0.64565344 587.75 -1.81112054e+00 5.74804634e+00 6.02662379e+00 1.87603406 0.68842903 588.00 -1.63352525e+00 5.96508685e+00 6.18471227e+00 1.83809093 0.62337237 588.25 -1.83902785e+00 6.67629564e+00 6.92495104e+00 1.83958673 0.56705055 588.50 -1.82863356e+00 8.45338587e+00 8.64890938e+00 1.78383350 0.64182090 588.75 1.14863462e+00 1.05695340e+01 1.06317642e+01 1.46254703 0.67688748 589.00 2.35120178e+00 1.03995535e+01 1.06620291e+01 1.34844769 0.70187738 589.25 6.46931564e+00 9.55576055e+00 1.15396969e+01 0.97566924 0.78483318 589.50 8.30946819e+00 8.96299376e+00 1.22222142e+01 0.82321640 0.76908737 589.75 9.17457909e+00 6.42958418e+00 1.12032341e+01 0.61126554 0.64126967 590.00 9.53200366e+00 6.92164579e+00 1.17799947e+01 0.62806029 0.65787544 590.25 1.13927319e+01 8.10172387e+00 1.39797092e+01 0.61815738 0.69378094 590.50 1.36814598e+01 5.34869737e+00 1.46898232e+01 0.37267599 0.64922214 590.75 1.57963448e+01 1.48515282e+00 1.58660073e+01 0.09374320 0.65893818 591.00 1.62981362e+01 -5.84051906e-01 1.63085977e+01 -0.03582017 0.74839621 591.25 1.73230443e+01 -3.56495937e+00 1.76860623e+01 -0.20295939 0.82714978 591.50 1.62400691e+01 -5.86023759e+00 1.72650580e+01 -0.34630833 0.82402925 591.75 1.61093900e+01 -7.01914957e+00 1.75721628e+01 -0.41091367 0.88083678 592.00 1.39763397e+01 -7.55281956e+00 1.58865715e+01 -0.49544322 0.86746093 592.25 1.28378308e+01 -8.20858665e+00 1.52378081e+01 -0.56889171 0.85017921 592.50 1.30440990e+01 -9.43242284e+00 1.60971774e+01 -0.62607350 0.85589755 592.75 1.27980628e+01 -1.08431111e+01 1.67738925e+01 -0.70289321 0.90984368 593.00 1.20667032e+01 -1.07878958e+01 1.61859205e+01 -0.72950240 0.89209440 593.25 1.19066360e+01 -1.18850567e+01 1.68232742e+01 -0.78449115 0.90012508 593.50 1.17127914e+01 -1.32769198e+01 1.77049734e+01 -0.84790752 0.87948467 593.75 1.11186120e+01 -1.43983674e+01 1.81916606e+01 -0.91322957 0.83637930 594.00 9.12449966e+00 -1.46039068e+01 1.72200635e+01 -1.01234189 0.75179190 594.25 6.45992701e+00 -1.70526123e+01 1.82351925e+01 -1.20867794 0.79888807 594.50 3.17190848e+00 -1.70213567e+01 1.73143752e+01 -1.38656076 0.80712905 594.75 1.58195194e+00 -1.69996448e+01 1.70730927e+01 -1.47800562 0.86136653 595.00 7.95396352e-01 -1.58091279e+01 1.58291244e+01 -1.52052624 0.85639055 595.25 7.97529932e-02 -1.55062915e+01 1.55064966e+01 -1.56565311 0.85605577 595.50 -1.99459997e-01 -1.44828363e+01 1.44842098e+01 -1.58456762 0.84202534 595.75 -1.53100213e+00 -1.43988805e+01 1.44800458e+01 -1.67672618 0.83495799 596.00 -1.78531734e+00 -1.38301334e+01 1.39448896e+01 -1.69917531 0.82374992 596.25 -1.42830894e+00 -1.31888619e+01 1.32659770e+01 -1.67867251 0.85324044 596.50 -7.24707727e-01 -1.37126239e+01 1.37317609e+01 -1.62359688 0.84457606 596.75 -5.86657843e-01 -1.53563998e+01 1.53676017e+01 -1.60898058 0.89180469 597.00 -1.93215131e+00 -1.72969024e+01 1.74044834e+01 -1.68204020 0.91441152 597.25 -3.46245542e+00 -1.90859638e+01 1.93974898e+01 -1.75025827 0.90499105 597.50 -8.64633640e+00 -1.92301270e+01 2.10845184e+01 -1.99333795 0.85276863 597.75 -1.20985296e+01 -1.75518900e+01 2.13176748e+01 -2.17430538 0.90130346 598.00 -1.41416132e+01 -1.42248591e+01 2.00582113e+01 -2.35325984 0.90958906 598.25 -1.47471428e+01 -1.18913975e+01 1.89442222e+01 -2.46299014 0.90818183 598.50 -1.51853813e+01 -9.92782262e+00 1.81426974e+01 -2.56256823 0.92582983 598.75 -1.52967020e+01 -8.84970375e+00 1.76721914e+01 -2.61710450 0.91813532 599.00 -1.41451166e+01 -6.85138203e+00 1.57170531e+01 -2.69053209 0.90552004 599.25 -1.42489068e+01 -6.11498737e+00 1.55056253e+01 -2.73620809 0.90159483 599.50 -1.46316392e+01 -4.60735707e+00 1.53399023e+01 -2.83653189 0.83825832 599.75 -1.34201940e+01 -3.04053788e+00 1.37603225e+01 -2.91878971 0.79314794 600.00 -1.31639769e+01 -7.02324246e-01 1.31826987e+01 -3.08829121 0.80246893 600.25 -1.27120055e+01 -7.62637139e-01 1.27348616e+01 -3.08167102 0.81483191 600.50 -1.33448304e+01 8.13628327e-01 1.33696107e+01 3.08069848 0.85217687 600.75 -1.23141644e+01 1.49461463e+00 1.24045362e+01 3.02080983 0.82592073 601.00 -1.06220388e+01 3.23772239e+00 1.11045286e+01 2.84572726 0.73529872 601.25 -9.47050606e+00 5.38644983e+00 1.08951515e+01 2.62446016 0.65107311 601.50 -7.92496378e+00 8.52120139e+00 1.16368348e+01 2.31995646 0.62065000 601.75 -6.10374651e+00 9.82122215e+00 1.15633960e+01 2.12686432 0.60709843 602.00 -1.90664677e+00 1.06218572e+01 1.07916242e+01 1.74840705 0.61828761 602.25 1.24671062e+00 8.18776765e+00 8.28213900e+00 1.41969194 0.47379878 602.50 3.88262150e+00 4.03570234e+00 5.60014670e+00 0.80472824 0.48526034 602.75 4.66410333e+00 1.61327252e+00 4.93523131e+00 0.33300978 0.43717763 603.00 4.25704572e+00 -8.90997046e-01 4.34928891e+00 -0.20632108 0.48994703 603.25 2.85061721e+00 -2.61314968e+00 3.86711388e+00 -0.74196326 0.44490742 603.50 9.84120252e-01 -4.35543280e+00 4.46523096e+00 -1.34857561 0.61854975 603.75 -1.40503933e-01 -4.60680388e+00 4.60894602e+00 -1.60128610 0.71057246 604.00 -1.01662212e+00 -4.43270205e+00 4.54778716e+00 -1.79624341 0.73928481 604.25 -2.48172112e+00 -3.79507146e+00 4.53447980e+00 -2.14993118 0.68824121 604.50 -3.39937602e+00 -3.10837475e+00 4.60627299e+00 -2.40088083 0.71193055 604.75 -3.38704429e+00 -1.51083788e+00 3.70873295e+00 -2.72201688 0.53081803 605.00 -3.08228849e+00 -9.78856799e-01 3.23398561e+00 -2.83409129 0.51224658 605.25 -2.26694946e+00 -1.66207594e-01 2.27303428e+00 -3.06840587 0.26275380 605.50 -1.54903299e+00 4.34128973e-01 1.60871724e+00 2.86834467 0.15025819 605.75 -4.30153136e-01 1.90024246e-01 4.70256243e-01 2.72561260 0.01310976 606.00 1.62880630e-02 -1.79202956e-01 1.79941658e-01 -1.48015368 0.00272820 606.25 2.44502623e-01 -6.94231893e-01 7.36029520e-01 -1.23217044 0.03296039 606.50 3.53627250e-01 -7.93705485e-01 8.68919231e-01 -1.15165783 0.04333971 606.75 -3.42920608e-01 -1.53704764e+00 1.57483650e+00 -1.79030486 0.11579650 607.00 -6.67686642e-02 -1.43713038e+00 1.43868058e+00 -1.61722265 0.11354673 607.25 8.74415593e-01 -8.29317386e-01 1.20514313e+00 -0.75893411 0.08573752 607.50 1.24968841e+00 -1.14791655e+00 1.69688937e+00 -0.74297633 0.15035876 607.75 2.31019909e+00 -3.01374964e+00 3.79732890e+00 -0.91678514 0.39628699 608.00 2.86922549e+00 -4.43241372e+00 5.28003280e+00 -0.99630179 0.62124635 608.25 2.11661578e+00 -4.60888776e+00 5.07167711e+00 -1.14027963 0.67977143 608.50 1.37076933e+00 -4.99990442e+00 5.18440477e+00 -1.30321206 0.73288269 608.75 2.06406065e-01 -5.27229418e+00 5.27633295e+00 -1.53166712 0.80372729 609.00 -9.15275320e-02 -5.41314579e+00 5.41391952e+00 -1.58770310 0.85249702 609.25 -8.71385511e-01 -5.57181272e+00 5.63953984e+00 -1.72593143 0.85962915 609.50 -1.56033609e+00 -5.27262374e+00 5.49865527e+00 -1.85851650 0.85298429 609.75 -2.25427380e+00 -4.62638750e+00 5.14637850e+00 -2.02420362 0.90545206 610.00 -2.47214410e+00 -4.37949540e+00 5.02906318e+00 -2.08468974 0.89863286 610.25 -2.35370560e+00 -3.94023591e+00 4.58970468e+00 -2.10926608 0.89143898 610.50 -2.19821012e+00 -3.71423983e+00 4.31598253e+00 -2.10518912 0.91211765 610.75 -1.52318760e+00 -3.53892527e+00 3.85280321e+00 -1.97724006 0.92027467 611.00 -1.13122384e+00 -3.57987156e+00 3.75435051e+00 -1.87686267 0.91799986 611.25 -7.32090667e-01 -4.04977174e+00 4.11541102e+00 -1.74963821 0.92692329 611.50 -8.04591500e-01 -4.57190599e+00 4.64216457e+00 -1.74499854 0.92710087 611.75 -9.97398186e-01 -5.37555590e+00 5.46730321e+00 -1.75425333 0.95686215 612.00 -1.31020686e+00 -5.78390530e+00 5.93044708e+00 -1.79356308 0.95419269 612.25 -2.10372303e+00 -6.35739497e+00 6.69642602e+00 -1.89036394 0.96929716 612.50 -2.64904791e+00 -6.50020742e+00 7.01927000e+00 -1.95777961 0.96242494 612.75 -3.24511350e+00 -6.62718341e+00 7.37904612e+00 -2.02614348 0.97309639 613.00 -4.13100820e+00 -6.25415028e+00 7.49530683e+00 -2.15453334 0.95761520 613.25 -5.09255729e+00 -5.82995630e+00 7.74096442e+00 -2.28878494 0.97569470 613.50 -5.44683173e+00 -5.32186567e+00 7.61513165e+00 -2.36779853 0.96324980 613.75 -6.15656665e+00 -4.75584680e+00 7.77954958e+00 -2.48385663 0.96861109 614.00 -6.89105251e+00 -3.86186814e+00 7.89940696e+00 -2.63078637 0.95772528 614.25 -7.07943217e+00 -2.82607345e+00 7.62266692e+00 -2.76178049 0.96854838 614.50 -6.62933041e+00 -1.81866619e+00 6.87426857e+00 -2.87384355 0.95942797 614.75 -5.78650982e+00 -9.86231436e-01 5.86995301e+00 -2.97277846 0.95097440 615.00 -4.74620423e+00 -7.54384811e-01 4.80578308e+00 -2.98396635 0.92009519 615.25 -4.30314500e+00 -9.01412068e-01 4.39654417e+00 -2.93510094 0.94749635 615.50 -4.26439195e+00 -1.24307685e+00 4.44187784e+00 -2.85795073 0.93790513 615.75 -4.48326893e+00 -1.34041562e+00 4.67936046e+00 -2.85107029 0.95574120 616.00 -4.82448560e+00 -1.09478348e+00 4.94714182e+00 -2.91844927 0.96446028 616.25 -4.90697546e+00 -7.19056732e-01 4.95938007e+00 -2.99609056 0.96248066 616.50 -4.34922432e+00 -9.52482258e-02 4.35026717e+00 -3.11969610 0.91605369 616.75 -3.73557781e+00 4.30916305e-01 3.76034977e+00 3.02674561 0.91400503 617.00 -3.05783894e+00 4.89141371e-01 3.09671411e+00 2.98297338 0.91747061 617.25 -2.69728197e+00 4.33193669e-01 2.73184677e+00 2.98234874 0.93505174 617.50 -2.32162428e+00 1.64647874e-01 2.32745531e+00 3.07079193 0.89088121 617.75 -2.05550070e+00 7.57950042e-02 2.05689767e+00 3.10473512 0.86483152 618.00 -1.57494315e+00 -2.90192743e-01 1.60145489e+00 -2.95938035 0.75713403 618.25 -1.35337959e+00 -3.72966593e-01 1.40383061e+00 -2.87268576 0.78419947 618.50 -1.31971610e+00 -7.12987201e-01 1.50000044e+00 -2.64625965 0.79590614 618.75 -1.19280132e+00 -1.02098634e+00 1.57009174e+00 -2.43365054 0.80796744 619.00 -9.65205428e-01 -1.49965938e+00 1.78342361e+00 -2.14267089 0.85161512 619.25 -9.39046482e-01 -1.79690758e+00 2.02748246e+00 -2.05235243 0.87941169 619.50 -9.04625939e-01 -2.30367897e+00 2.47493129e+00 -1.94498297 0.89363078 619.75 -8.63798069e-01 -2.51036877e+00 2.65482551e+00 -1.90219832 0.88402793 620.00 -7.60308913e-01 -3.40364866e+00 3.48753406e+00 -1.79056882 0.92840382 620.25 -9.81153641e-01 -3.78431271e+00 3.90943540e+00 -1.82447922 0.93405885 620.50 -2.07918834e+00 -4.35161549e+00 4.82281883e+00 -2.01652420 0.93822394 620.75 -2.62567648e+00 -4.27720459e+00 5.01883015e+00 -2.12135689 0.95933728 621.00 -3.09475844e+00 -4.23463946e+00 5.24496912e+00 -2.20190869 0.96759517 621.25 -3.29506147e+00 -4.24436173e+00 5.37327057e+00 -2.23094210 0.96833736 621.50 -3.70301626e+00 -4.27357267e+00 5.65471067e+00 -2.28478723 0.97624024 621.75 -3.83668991e+00 -4.28320513e+00 5.75030745e+00 -2.30125955 0.97429420 622.00 -4.17749048e+00 -4.24672628e+00 5.95702197e+00 -2.34797601 0.96139362 622.25 -4.48706699e+00 -4.26500884e+00 6.19064379e+00 -2.38156110 0.94416823 622.50 -4.81151730e+00 -4.26941033e+00 6.43261714e+00 -2.41582104 0.92974315 622.75 -5.09859012e+00 -4.28529154e+00 6.66028114e+00 -2.44264819 0.90453404 623.00 -6.28925748e+00 -3.82251128e+00 7.35977935e+00 -2.59546913 0.89072693 623.25 -7.13843207e+00 -2.99786102e+00 7.74237581e+00 -2.74399806 0.90239573 623.50 -8.11487607e+00 -2.14572769e+00 8.39376918e+00 -2.88308985 0.92668364 623.75 -7.97139056e+00 -1.73723948e+00 8.15849670e+00 -2.92701353 0.86689142 624.00 -7.60828091e+00 -6.79752085e-01 7.63858635e+00 -3.05248553 0.85018898 624.25 -6.97318853e+00 5.25705936e-01 6.99297683e+00 3.06634539 0.84495308 624.50 -6.43558871e+00 1.53263131e+00 6.61556957e+00 2.90779826 0.86741423 624.75 -6.15252161e+00 1.98364117e+00 6.46439126e+00 2.82970412 0.89762418 625.00 -6.00122593e+00 2.09237483e+00 6.35552870e+00 2.80611397 0.91853071 625.25 -5.07361838e+00 2.34525222e+00 5.58943749e+00 2.70860298 0.88224342 625.50 -4.41075963e+00 2.69029289e+00 5.16647620e+00 2.59389733 0.88116640 625.75 -3.98965228e+00 2.55050538e+00 4.73522998e+00 2.57279033 0.89941971 626.00 -3.57770457e+00 2.40720063e+00 4.31214389e+00 2.54933263 0.92171822 626.25 -3.09171127e+00 2.51359400e+00 3.98457443e+00 2.45896862 0.90849615 626.50 -2.81599151e+00 2.44356467e+00 3.72837988e+00 2.42688605 0.90569156 626.75 -2.63332260e+00 2.13570346e+00 3.39051872e+00 2.46016223 0.89182882 627.00 -2.31021928e+00 1.76186865e+00 2.90539055e+00 2.49005008 0.84775656 627.25 -1.88394194e+00 1.34306739e+00 2.31366965e+00 2.52225951 0.76657545 627.50 -1.50718589e+00 1.15320028e+00 1.89775662e+00 2.48847547 0.73497336 627.75 -1.16547663e+00 4.54567506e-01 1.25098657e+00 2.76971303 0.41798892 628.00 -9.27412357e-01 -4.43415692e-01 1.02796457e+00 -2.69560062 0.29702058 628.25 -1.07511741e+00 -1.65373673e+00 1.97249147e+00 -2.14725169 0.58418007 628.50 -1.29347741e+00 -2.25572637e+00 2.60026639e+00 -2.09144198 0.70802896 628.75 -2.46456638e+00 -3.29257188e+00 4.11279917e+00 -2.21335160 0.77434957 629.00 -3.56799491e+00 -3.38668670e+00 4.91937338e+00 -2.38225854 0.81162477 629.25 -5.57781089e+00 -2.54681081e+00 6.13173871e+00 -2.71326636 0.81798400 629.50 -6.53193209e+00 -2.12833385e+00 6.86993026e+00 -2.82660547 0.82898573 629.75 -7.10020735e+00 -9.11220263e-01 7.15844025e+00 -3.01395323 0.87286555 630.00 -7.53414125e+00 -3.09691725e-01 7.54050352e+00 -3.10051067 0.88761949 630.25 -7.92762307e+00 1.24558675e+00 8.02487968e+00 2.98574693 0.79884755 630.50 -8.38585511e+00 2.25034426e+00 8.68254659e+00 2.87941934 0.80210109 630.75 -7.43983041e+00 3.35733935e+00 8.16227934e+00 2.71768677 0.67105627 631.00 -6.04837196e+00 4.51687697e+00 7.54883971e+00 2.50014770 0.65084763 631.25 -4.18787747e+00 5.81836395e+00 7.16879884e+00 2.19466717 0.68318710 631.50 -3.27311571e+00 5.07704945e+00 6.04067195e+00 2.14342861 0.66664202 631.75 -1.44725763e+00 3.66095026e+00 3.93663708e+00 1.94726427 0.61361155 632.00 -1.21002280e+00 3.35393047e+00 3.56553008e+00 1.91704007 0.58968308 632.25 -1.34062585e+00 2.81796959e+00 3.12061376e+00 2.01484971 0.50901579 632.50 -1.27936403e+00 2.44163474e+00 2.75651093e+00 2.05344218 0.48096557 632.75 -1.00982852e+00 2.02150097e+00 2.25969463e+00 2.03407900 0.65010936 633.00 -1.21526947e+00 2.10373092e+00 2.42951922e+00 2.09463744 0.74674810 633.25 -2.03307551e+00 2.25951156e+00 3.03953755e+00 2.30349285 0.79267160 633.50 -2.04780341e+00 1.86001381e+00 2.76643276e+00 2.40421241 0.67915711 633.75 -1.83106240e+00 1.53326469e+00 2.38823996e+00 2.44448067 0.62421407 634.00 -2.11757504e+00 1.77120440e+00 2.76066823e+00 2.44502931 0.71944452 634.25 -2.30412197e+00 1.82815625e+00 2.94128090e+00 2.47087153 0.77831286 634.50 -2.21680669e+00 2.12917828e+00 3.07370005e+00 2.37635483 0.77531947 634.75 -2.53747618e+00 2.35367216e+00 3.46100534e+00 2.39375572 0.83063753 635.00 -2.55785257e+00 2.34695941e+00 3.47143029e+00 2.39916522 0.79895250 635.25 -2.41401870e+00 2.79377819e+00 3.69224632e+00 2.28340200 0.75206176 635.50 -1.87322400e+00 3.31349530e+00 3.80633936e+00 2.08533428 0.72937293 635.75 -1.43698260e+00 2.86933857e+00 3.20905326e+00 2.03508870 0.60731432 636.00 -4.87034002e-01 2.68054301e+00 2.72442892e+00 1.75052796 0.37010368 636.25 -1.18773503e-01 2.61119709e+00 2.61389698e+00 1.61625122 0.38654449 636.50 -8.90482765e-01 2.20950834e+00 2.38220206e+00 1.95390605 0.41688366 636.75 -8.90273384e-01 1.58453206e+00 1.81750614e+00 2.08269382 0.22444442 637.00 -4.76424394e-01 2.18613846e+00 2.23744979e+00 1.78537101 0.19954128 637.25 -1.12001033e+00 2.03475333e+00 2.32263735e+00 2.07397755 0.17843610 637.50 -2.00309147e+00 3.01195982e+00 3.61721956e+00 2.15767601 0.36570795 637.75 -2.21195664e+00 3.56868344e+00 4.19860139e+00 2.12566512 0.43788578 638.00 -9.02601025e-01 3.81071516e+00 3.91615100e+00 1.80336898 0.34952971 638.25 1.22473146e+00 3.84201019e+00 4.03249419e+00 1.26220625 0.33474127 638.50 2.33287596e+00 3.65483491e+00 4.33591149e+00 1.00269109 0.42281204 638.75 3.12034998e+00 3.21208514e+00 4.47817764e+00 0.79988370 0.46348919 639.00 3.71110879e+00 1.84437954e+00 4.14416027e+00 0.46123576 0.40451642 639.25 3.67589318e+00 6.76445756e-01 3.73761549e+00 0.18198611 0.42066103 639.50 2.83906905e+00 -9.21055452e-01 2.98473721e+00 -0.31370871 0.52551478 639.75 2.50923998e+00 -1.62819597e+00 2.99120501e+00 -0.57558756 0.58384415 640.00 1.37804700e+00 -1.84367292e+00 2.30176962e+00 -0.92893142 0.56655927 640.25 8.45176881e-01 -1.76510210e+00 1.95701543e+00 -1.12423090 0.53255060 640.50 -1.35052061e-01 -1.40266059e+00 1.40914719e+00 -1.66678322 0.45449916 640.75 -5.31290358e-01 -1.22811816e+00 1.33811198e+00 -1.97909101 0.48779627 641.00 -8.94361726e-01 -7.88135484e-01 1.19207401e+00 -2.41924686 0.39257057 641.25 -1.06929928e+00 -5.27849971e-01 1.19248754e+00 -2.68304517 0.32773063 641.50 -1.00752433e+00 -1.55540856e-01 1.01945977e+00 -2.98842259 0.26128094 641.75 -9.70601627e-01 2.28852373e-01 9.97216590e-01 2.91003782 0.26516442 642.00 -9.38777866e-01 6.22024405e-01 1.12615196e+00 2.55641798 0.33846746 642.25 -7.46355460e-01 7.09606451e-01 1.02984843e+00 2.38142950 0.30176996 642.50 -5.57212573e-01 1.14597450e-01 5.68874702e-01 2.93875884 0.13799042 642.75 -5.58771415e-01 1.22968802e-01 5.72142308e-01 2.92497562 0.18567065 643.00 -7.12384336e-01 -1.10192342e-01 7.20856292e-01 -2.98812786 0.24938474 643.25 -7.91139992e-01 -3.27456502e-01 8.56230254e-01 -2.74915730 0.37656573 643.50 -1.29961177e+00 -1.79112291e-01 1.31189632e+00 -3.00463560 0.80311990 643.75 -1.43474419e+00 -4.30561449e-02 1.43539009e+00 -3.11159203 0.78154385 644.00 -1.65813218e+00 1.47567404e-01 1.66468570e+00 3.05283034 0.79291146 644.25 -1.66571090e+00 3.44362650e-01 1.70093458e+00 2.93772850 0.77534442 644.50 -1.52840690e+00 5.69090070e-01 1.63091727e+00 2.78515432 0.80834678 644.75 -1.42851438e+00 5.52776338e-01 1.53173595e+00 2.77237892 0.73487873 645.00 -1.37364609e+00 5.25780663e-01 1.47083272e+00 2.77603365 0.75821137 645.25 -1.42573069e+00 4.75905935e-01 1.50306170e+00 2.81942403 0.74586059 645.50 -1.47173450e+00 4.80913356e-01 1.54831524e+00 2.82576395 0.77163764 645.75 -1.31735447e+00 4.89382180e-01 1.40531766e+00 2.78590401 0.66360989 646.00 -1.19495686e+00 3.85596255e-01 1.25562987e+00 2.82945480 0.55998456 646.25 -1.55867132e+00 2.96345249e-01 1.58659283e+00 2.95370829 0.57269150 646.50 -2.00218925e+00 3.46851563e-01 2.03201077e+00 2.97005893 0.69032162 646.75 -2.25817347e+00 1.03167052e+00 2.48267829e+00 2.71304810 0.70379956 647.00 -2.16733729e+00 1.37730839e+00 2.56794262e+00 2.57548971 0.71343845 647.25 -2.04722268e+00 1.91382239e+00 2.80246978e+00 2.38985982 0.62210041 647.50 -1.36361970e+00 2.10117745e+00 2.50487631e+00 2.14645335 0.52365231 647.75 -8.28969630e-01 1.52927062e+00 1.73949972e+00 2.06752981 0.36816792 648.00 -6.80850670e-01 1.53167757e+00 1.67618430e+00 1.98907795 0.35736475 648.25 -8.32388216e-01 1.38777776e+00 1.61826984e+00 2.11106829 0.29274846 648.50 -1.16699224e+00 1.42276284e+00 1.84014266e+00 2.25775127 0.32989220 648.75 -7.00434629e-01 1.98430056e+00 2.10429498e+00 1.91013073 0.42230650 649.00 -1.67555135e-01 2.26971702e+00 2.27589325e+00 1.64448470 0.50379695 649.25 3.09922272e-01 1.97040724e+00 1.99463192e+00 1.41478606 0.42363030 649.50 8.76285095e-01 1.69441437e+00 1.90759420e+00 1.09351433 0.42152266 649.75 1.40829096e+00 1.03607446e+00 1.74835171e+00 0.63428372 0.36167863 650.00 1.34210788e+00 6.20206337e-01 1.47848214e+00 0.43288183 0.30348799 650.25 1.44400601e+00 -1.60035212e-01 1.45284708e+00 -0.11037681 0.40492111 650.50 1.51747414e+00 -5.36814539e-01 1.60962654e+00 -0.34001638 0.50857407 650.75 1.30488513e+00 -1.70002093e+00 2.14308104e+00 -0.91614490 0.58834152 651.00 1.16469584e+00 -2.29387756e+00 2.57262330e+00 -1.10097506 0.71357072 651.25 5.22087653e-01 -2.93773190e+00 2.98376344e+00 -1.39491471 0.78725065 651.50 -7.68060826e-02 -3.17899741e+00 3.17992511e+00 -1.59495210 0.76240314 651.75 -1.00604357e+00 -3.52298444e+00 3.66381536e+00 -1.84895862 0.81054777 652.00 -1.15814305e+00 -3.53130937e+00 3.71637474e+00 -1.88770690 0.82066625 652.25 -1.18548517e+00 -3.68386678e+00 3.86991596e+00 -1.88213536 0.81043393 652.50 -1.10229647e+00 -3.94308451e+00 4.09426098e+00 -1.84338939 0.76381746 652.75 -1.40600243e+00 -4.93553371e+00 5.13189398e+00 -1.84831842 0.79352493 653.00 -2.13211279e+00 -5.35969425e+00 5.76820833e+00 -1.94940897 0.82673088 653.25 -3.28725447e+00 -6.65215060e+00 7.42005051e+00 -2.02976438 0.85005070 653.50 -3.98886313e+00 -6.76458466e+00 7.85306530e+00 -2.10358457 0.81659618 653.75 -4.51709974e+00 -6.64337057e+00 8.03358964e+00 -2.16793261 0.80476625 654.00 -5.66839077e+00 -5.96852229e+00 8.23127647e+00 -2.33040887 0.77764688 654.25 -6.96347097e+00 -4.78053475e+00 8.44650463e+00 -2.53997374 0.73268190 654.50 -7.07524285e+00 -4.21115008e+00 8.23364114e+00 -2.60471364 0.66026254 654.75 -6.01799589e+00 -1.62670925e+00 6.23397606e+00 -2.87759426 0.48483497 655.00 -3.35415907e+00 2.50112363e-01 3.36347131e+00 3.06716257 0.26026983 655.25 -2.70131534e-01 8.65028705e-01 9.06226078e-01 1.87348114 0.03034580 655.50 2.56942102e+00 -5.02941611e-01 2.61818155e+00 -0.19329725 0.17499068 655.75 5.61469106e+00 -1.09245030e+00 5.71998281e+00 -0.19216897 0.46079768 656.00 8.17343650e+00 -5.33759325e+00 9.76191405e+00 -0.57851039 0.56979234 656.25 8.96720585e+00 -8.90477665e+00 1.26374771e+01 -0.78190505 0.68676301 656.50 8.07270740e+00 -9.45208095e+00 1.24302228e+01 -0.86394608 0.59166492 656.75 8.06200108e+00 -9.66471103e+00 1.25858055e+01 -0.87556515 0.58216550 657.00 4.07865985e+00 -9.19756769e+00 1.00613477e+01 -1.15340286 0.42743785 657.25 8.61976881e-01 -8.78336791e+00 8.82556265e+00 -1.47297217 0.37992344 657.50 2.02235854e+00 -7.94481651e+00 8.19817318e+00 -1.32153927 0.21281794 657.75 4.19201832e+00 -5.72373888e+00 7.09466027e+00 -0.93866016 0.15859713 658.00 4.41776432e+00 -8.88221045e+00 9.92019677e+00 -1.10925319 0.16872082 658.25 4.27106992e+00 -1.08255438e+01 1.16376302e+01 -1.19500890 0.14670607 658.50 2.92640485e+00 -1.72826226e+01 1.75286305e+01 -1.40306089 0.30933204 658.75 1.11195396e+00 -1.71480214e+01 1.71840356e+01 -1.50604254 0.29551589 659.00 9.28167383e-01 -1.49916840e+01 1.50203890e+01 -1.50896310 0.19333137 659.25 -1.58255539e+00 -1.63871853e+01 1.64634238e+01 -1.66707051 0.20212713 659.50 -4.11106073e+00 -1.83233085e+01 1.87788299e+01 -1.79150377 0.20227580 659.75 -1.23871391e+01 -1.65931111e+01 2.07068238e+01 -2.21206844 0.19830706 660.00 -2.12251257e+01 -1.07037094e+01 2.37713137e+01 -2.67451553 0.24139946 660.25 -2.07644946e+01 -1.12871748e+01 2.36339703e+01 -2.64369138 0.23055622 660.50 -1.95901601e+01 -1.26367320e+01 2.33122579e+01 -2.56870152 0.36337253 660.75 -2.22366212e+01 -1.08246870e+01 2.47313803e+01 -2.68856434 0.46406238 661.00 -2.68227461e+01 -9.81512979e+00 2.85621512e+01 -2.79080125 0.59433736 661.25 -2.09354740e+01 -1.27275864e+01 2.45007250e+01 -2.59535277 0.49162486 661.50 -1.68760655e+01 -1.28834644e+01 2.12317037e+01 -2.48956023 0.41550976 661.75 -1.94856574e+01 -1.37996292e+01 2.38771985e+01 -2.52538838 0.34077691 662.00 -2.65657830e+01 -2.47063400e+01 3.62786998e+01 -2.39244476 0.40258687 662.25 -2.98658014e+01 -2.25457004e+01 3.74202445e+01 -2.49496277 0.39604778 662.50 -2.99392242e+01 -2.64227640e+01 3.99314362e+01 -2.41850436 0.42350766 662.75 -3.11543696e+01 -1.86823456e+01 3.63266401e+01 -2.60141572 0.41912703 663.00 -4.01760484e+01 -1.00417465e+01 4.14119734e+01 -2.89666707 0.58716195 663.25 -3.54908652e+01 -7.14589534e+00 3.62031122e+01 -2.94290451 0.61662370 663.50 -2.97262021e+01 -3.17220660e+00 2.98949826e+01 -3.03528083 0.72449881 663.75 -2.53852052e+01 -5.79557379e+00 2.60383816e+01 -2.91713453 0.69389959 664.00 -2.10582991e+01 -8.00924386e+00 2.25299789e+01 -2.77815147 0.66975455 664.25 -1.56018239e+01 -7.59607899e+00 1.73527325e+01 -2.68850313 0.48255979 664.50 -8.13445781e+00 -1.01131848e+01 1.29786714e+01 -2.24817914 0.39535569 664.75 -5.15544561e+00 -9.52930587e+00 1.08344954e+01 -2.06671090 0.28433470 665.00 2.87926473e+00 -4.27242648e+00 5.15206691e+00 -0.97779042 0.08405593 665.25 7.20232362e+00 -1.48007406e+00 7.35282835e+00 -0.20267793 0.16762197 665.50 9.33589554e+00 5.09261973e+00 1.06345532e+01 0.49937257 0.38237055 665.75 1.00292626e+01 5.15489339e+00 1.12764814e+01 0.47477314 0.30012090 666.00 1.24314734e+01 2.33884834e+00 1.26495748e+01 0.18596544 0.24236019 666.25 1.49152651e+01 5.25806281e-01 1.49245303e+01 0.03523830 0.30176561 666.50 1.65064516e+01 -1.56580567e+00 1.65805516e+01 -0.09457722 0.28705992 666.75 1.77953409e+01 -4.34019226e+00 1.83169710e+01 -0.23922445 0.26478593 667.00 2.26495376e+01 -5.87874551e-01 2.26571655e+01 -0.02594943 0.32661057 667.25 2.35471201e+01 -4.45072562e+00 2.39640528e+01 -0.18680973 0.42900737 667.50 2.41736607e+01 -8.37921803e+00 2.55847057e+01 -0.33366583 0.48211713 667.75 2.68500161e+01 -4.41530233e+00 2.72106277e+01 -0.16298452 0.58769374 668.00 2.92798684e+01 -5.10554029e+00 2.97216628e+01 -0.17263464 0.67266713 668.25 2.72524942e+01 -6.47081365e+00 2.80101744e+01 -0.23312236 0.70096243 668.50 2.51457977e+01 -6.29196753e+00 2.59210338e+01 -0.24518519 0.75812702 668.75 2.31544840e+01 -3.16134870e+00 2.33693015e+01 -0.13569388 0.78957300 669.00 2.20602925e+01 -1.52605946e+00 2.21130134e+01 -0.06906672 0.80744863 669.25 2.22108679e+01 8.84324059e-01 2.22284656e+01 0.03979391 0.84979588 669.50 2.32471601e+01 2.29847515e+00 2.33605103e+01 0.09855093 0.87366679 669.75 2.49413502e+01 -1.49622844e+00 2.49861891e+01 -0.05991806 0.83167078 670.00 2.64980930e+01 -3.31231675e+00 2.67043137e+01 -0.12435704 0.84572758 670.25 2.94467832e+01 -6.62884444e+00 3.01836814e+01 -0.22142169 0.79312804 670.50 2.98823999e+01 -1.08021603e+01 3.17749035e+01 -0.34687316 0.77384556 670.75 2.64662402e+01 -1.38916958e+01 2.98904848e+01 -0.48335576 0.74780199 671.00 2.42013294e+01 -1.46452287e+01 2.82875780e+01 -0.54419144 0.69756544 671.25 1.98015272e+01 -1.66030840e+01 2.58411083e+01 -0.69776499 0.68419409 671.50 1.72007954e+01 -1.58368100e+01 2.33810161e+01 -0.74413575 0.68948597 671.75 1.01053003e+01 -1.48128084e+01 1.79314357e+01 -0.97211672 0.66898245 672.00 8.53212523e+00 -1.45748951e+01 1.68885976e+01 -1.04118224 0.72253694 672.25 5.31837343e+00 -1.22491522e+01 1.33539068e+01 -1.16117339 0.62868020 672.50 3.91209572e+00 -9.17933950e+00 9.97821460e+00 -1.16792250 0.54269398 672.75 2.96173652e+00 -4.87902844e+00 5.70760911e+00 -1.02522076 0.37965240 673.00 1.98866983e+00 -3.86220114e+00 4.34412308e+00 -1.09529530 0.27142294 673.25 1.55388039e+00 -1.93848487e+00 2.48440493e+00 -0.89508339 0.12348881 673.50 1.98551526e+00 -1.18036182e+00 2.30987551e+00 -0.53635552 0.09888271 673.75 1.87612440e+00 7.05298738e-01 2.00431761e+00 0.35958917 0.05448949 674.00 1.37221961e+00 1.34105950e+00 1.91870457e+00 0.77391437 0.05036528 674.25 7.11938837e-01 8.66306510e-01 1.12131346e+00 0.88289772 0.02734834 674.50 -1.16992368e+00 -1.10776401e-02 1.16997613e+00 -3.13212425 0.02359566 674.75 -3.44466756e+00 -3.54940397e-01 3.46290590e+00 -3.03891448 0.19934628 675.00 -4.80064939e+00 -3.00568149e-01 4.81004946e+00 -3.07906438 0.28825862 675.25 -7.61220346e+00 -1.88556582e+00 7.84225732e+00 -2.89877702 0.61080186 675.50 -9.18850438e+00 -2.59455273e+00 9.54779119e+00 -2.86638813 0.66425383 675.75 -1.26294838e+01 -4.56212128e+00 1.34282096e+01 -2.79495052 0.78371439 676.00 -1.30638501e+01 -7.24074376e+00 1.49362830e+01 -2.63548620 0.74623572 676.25 -1.42701301e+01 -1.19600059e+01 1.86193006e+01 -2.44403921 0.80039312 676.50 -1.47577575e+01 -1.49609369e+01 2.10147815e+01 -2.34935784 0.82252373 676.75 -1.46791332e+01 -1.81391380e+01 2.33346369e+01 -2.25115331 0.84099346 677.00 -1.63316573e+01 -2.02176452e+01 2.59899251e+01 -2.25027062 0.81444363 677.25 -1.48189937e+01 -2.15512201e+01 2.61544961e+01 -2.17316338 0.77816543 677.50 -1.74375630e+01 -2.18709554e+01 2.79715443e+01 -2.24388457 0.83147114 677.75 -1.96208380e+01 -2.26149305e+01 2.99401464e+01 -2.28542291 0.87929292 678.00 -1.80997444e+01 -2.10347306e+01 2.77499664e+01 -2.28133717 0.85193955 678.25 -1.89950994e+01 -1.94547905e+01 2.71901209e+01 -2.34423947 0.85331316 678.50 -1.79122997e+01 -1.68635464e+01 2.46014161e+01 -2.38634287 0.91200707 678.75 -1.77380874e+01 -1.60417307e+01 2.39160379e+01 -2.40637039 0.94074051 679.00 -1.71264828e+01 -1.67268259e+01 2.39395722e+01 -2.36799949 0.92175182 679.25 -1.69715826e+01 -1.77816504e+01 2.45809215e+01 -2.33288958 0.91998682 679.50 -1.88097375e+01 -1.71470141e+01 2.54524325e+01 -2.40240388 0.92054252 679.75 -1.94203596e+01 -1.54107328e+01 2.47919554e+01 -2.47080631 0.92765804 680.00 -2.08325519e+01 -1.09177813e+01 2.35200589e+01 -2.65887251 0.90833783 680.25 -2.12843233e+01 -8.83730135e+00 2.30460477e+01 -2.74804987 0.91270818 680.50 -2.07390008e+01 -7.08240792e+00 2.19149870e+01 -2.81250850 0.86154654 680.75 -2.10930123e+01 -3.29030922e+00 2.13480984e+01 -2.98684925 0.83462140 681.00 -1.96976728e+01 -1.35212596e-01 1.96981369e+01 -3.13472837 0.84452484 681.25 -1.84158646e+01 5.57281097e-01 1.84242946e+01 3.11134096 0.82606663 681.50 -1.47903657e+01 3.77376939e-01 1.47951794e+01 3.11608314 0.77072657 681.75 -1.44125351e+01 1.03203221e+00 1.44494380e+01 3.07010810 0.79357187 682.00 -1.37204767e+01 3.03907242e+00 1.40530225e+01 2.92361296 0.83127357 682.25 -1.23870654e+01 4.27058967e+00 1.31025694e+01 2.80959179 0.82698895 682.50 -1.11273997e+01 5.21151228e+00 1.22873465e+01 2.70358448 0.81609441 682.75 -1.03125094e+01 5.74135369e+00 1.18030078e+01 2.63359194 0.80008853 683.00 -8.97027307e+00 6.85658167e+00 1.12906382e+01 2.48895983 0.87225719 683.25 -8.53245604e+00 6.68488951e+00 1.08393060e+01 2.47701502 0.89970812 683.50 -7.86874728e+00 6.33543594e+00 1.01022241e+01 2.46372597 0.92120121 683.75 -7.49414564e+00 5.93397075e+00 9.55898675e+00 2.47186304 0.91272371 684.00 -6.85725426e+00 5.68435410e+00 8.90695333e+00 2.44944398 0.89137669 684.25 -6.59744867e+00 5.70289542e+00 8.72062756e+00 2.42879255 0.89792271 684.50 -6.66811860e+00 5.74470291e+00 8.80144404e+00 2.43044980 0.91773255 684.75 -6.79417317e+00 5.56763317e+00 8.78403826e+00 2.45509093 0.92406919 685.00 -7.04259538e+00 5.26553466e+00 8.79340690e+00 2.49958465 0.91741252 685.25 -7.52605048e+00 5.16817285e+00 9.12970134e+00 2.53984568 0.88488380 685.50 -7.43251810e+00 5.93519829e+00 9.51151429e+00 2.46773969 0.84872279 685.75 -8.10353182e+00 6.69581461e+00 1.05119533e+01 2.45102939 0.75382370 686.00 -9.48171882e+00 7.56748829e+00 1.21313590e+01 2.46800304 0.71214606 686.25 -8.21956500e+00 8.56974069e+00 1.18744138e+01 2.33534045 0.60573170 686.50 -4.13916880e+00 1.29898157e+01 1.36333426e+01 1.87927168 0.59709648 686.75 7.42942830e-01 1.42688920e+01 1.42882204e+01 1.51877599 0.62030921 687.00 5.30456673e+00 1.45176543e+01 1.54564134e+01 1.22047973 0.66604270 687.25 7.89710051e+00 1.39972035e+01 1.60712757e+01 1.05712301 0.67004713 687.50 8.35199005e+00 1.21259310e+01 1.47239241e+01 0.96764640 0.63077710 687.75 8.96559643e+00 9.60116469e+00 1.31363725e+01 0.81961631 0.55270351 688.00 8.70519596e+00 9.42967605e+00 1.28335197e+01 0.82532649 0.57447413 688.25 1.00012221e+01 4.70569232e+00 1.10529626e+01 0.43977995 0.31946441 688.50 1.13914962e+01 9.23123367e-01 1.14288381e+01 0.08085949 0.35470943 688.75 8.86619382e+00 -4.89049181e+00 1.01255273e+01 -0.50406208 0.41429142 689.00 6.51653391e+00 -6.40982366e+00 9.14062654e+00 -0.77714311 0.54201232 689.25 5.17182961e+00 -4.95224895e+00 7.16048819e+00 -0.76371261 0.55995541 689.50 4.19896369e+00 -5.20123458e+00 6.68461945e+00 -0.89161917 0.67207983 689.75 3.43843237e+00 -3.81522895e+00 5.13602853e+00 -0.83729723 0.63685839 690.00 3.37479617e+00 -2.95894342e+00 4.48827309e+00 -0.71983552 0.61327301 690.25 3.75665888e+00 -1.34880929e+00 3.99146245e+00 -0.34470982 0.37056148 690.50 3.51071202e+00 2.78501461e-01 3.52174132e+00 0.07916327 0.20831161 690.75 3.78765958e+00 -5.52076987e+00 6.69516729e+00 -0.96947759 0.36035050 691.00 3.91837854e+00 -6.41207550e+00 7.51454607e+00 -1.02225965 0.47353996 691.25 1.23833813e+00 -5.54321441e+00 5.67985099e+00 -1.35100805 0.38709849 691.50 1.02947303e+00 -6.44147506e+00 6.52322127e+00 -1.41231711 0.58252782 691.75 1.28543856e+00 -7.65817030e+00 7.76530261e+00 -1.40449466 0.74259832 692.00 9.76026761e-01 -7.99547257e+00 8.05482525e+00 -1.44932489 0.74790489 692.25 4.20870540e-01 -7.16212261e+00 7.17447784e+00 -1.51210045 0.65111599 692.50 1.51073236e-01 -7.27359061e+00 7.27515934e+00 -1.55002921 0.65590464 692.75 -1.50151100e+00 -8.20728422e+00 8.34350343e+00 -1.75174383 0.69266787 693.00 -3.36142753e+00 -8.45642348e+00 9.10001610e+00 -1.94914559 0.70908011 693.25 -5.43740827e+00 -8.46067185e+00 1.00572549e+01 -2.14200040 0.76954338 693.50 -6.24565103e+00 -8.72742307e+00 1.07320115e+01 -2.19193881 0.73178942 693.75 -9.03750762e+00 -7.64567073e+00 1.18377711e+01 -2.43942930 0.72182691 694.00 -1.05749786e+01 -7.40676804e+00 1.29108631e+01 -2.53059492 0.76675271 694.25 -1.27942939e+01 -7.21192017e+00 1.46869244e+01 -2.62830533 0.81024945 694.50 -1.42484653e+01 -4.15494592e+00 1.48419116e+01 -2.85785394 0.76590982 694.75 -1.59356958e+01 3.22696270e+00 1.62591417e+01 2.94179535 0.80279664 695.00 -1.44665760e+01 5.87365362e+00 1.56135079e+01 2.75591131 0.77515057 695.25 -1.00453624e+01 8.57733681e+00 1.32090882e+01 2.43486171 0.76400368 695.50 -7.87924207e+00 9.36793481e+00 1.22409419e+01 2.27009274 0.79856437 695.75 -4.62280601e+00 8.86689663e+00 9.99960955e+00 2.05138207 0.84653587 696.00 -3.44392202e+00 7.92596108e+00 8.64184344e+00 1.98069572 0.83355773 696.25 -2.93437770e+00 6.92418033e+00 7.52029559e+00 1.97163912 0.81188065 696.50 -2.30964130e+00 6.64481230e+00 7.03476890e+00 1.90531865 0.78607686 696.75 -1.97586368e+00 6.28875365e+00 6.59184798e+00 1.87522012 0.79716962 697.00 -2.08224126e+00 6.32775811e+00 6.66155022e+00 1.88870012 0.81036870 697.25 -1.77205553e+00 6.52327649e+00 6.75968320e+00 1.83604648 0.89305181 697.50 -1.16650572e+00 6.58720317e+00 6.68969217e+00 1.74606592 0.92647837 697.75 -4.22846615e-01 6.50524894e+00 6.51897715e+00 1.63570585 0.94728624 698.00 4.29604633e-01 5.96865593e+00 5.98409674e+00 1.49894346 0.89865202 698.25 1.27042132e+00 5.40321246e+00 5.55055630e+00 1.33986749 0.83604149 698.50 1.58925126e+00 4.48659895e+00 4.75975731e+00 1.23036538 0.64261841 698.75 1.42527231e+00 3.65417467e+00 3.92229444e+00 1.19890600 0.46149603 699.00 8.40334278e-01 3.07374231e+00 3.18654256e+00 1.30392636 0.32436299 699.25 7.85304265e-01 3.34708231e+00 3.43797364e+00 1.34034116 0.38698150 699.50 7.43934365e-01 3.45815970e+00 3.53727393e+00 1.35890131 0.33285151 699.75 4.78867507e-01 2.84174037e+00 2.88180541e+00 1.40385268 0.35953149 700.00 7.85914920e-02 2.83441775e+00 2.83550712e+00 1.54307587 0.42160452 700.25 -1.27532484e-01 2.71633906e+00 2.71933124e+00 1.61771201 0.53473447 700.50 2.73175637e-02 2.82508352e+00 2.82521559e+00 1.56112698 0.57849857 700.75 -6.66669896e-02 3.10062147e+00 3.10133810e+00 1.59229418 0.71811319 701.00 6.94077589e-02 3.55943319e+00 3.56010984e+00 1.55129913 0.70705616 701.25 4.63930377e-01 3.83150125e+00 3.85948614e+00 1.45029973 0.76438224 701.50 1.22068942e+00 3.69449583e+00 3.89093589e+00 1.25168126 0.80242167 701.75 1.59323542e+00 3.40924457e+00 3.76315661e+00 1.13362624 0.82404104 702.00 2.04945549e+00 2.76598561e+00 3.44252004e+00 0.93311278 0.81804688 702.25 2.31474615e+00 2.49402511e+00 3.40267703e+00 0.82266256 0.86147262 702.50 2.11102939e+00 1.44494142e+00 2.55818311e+00 0.60022858 0.72756294 702.75 1.96531948e+00 6.66132894e-01 2.07514185e+00 0.32679147 0.60981252 703.00 6.82154664e-01 -7.30472627e-01 9.99462477e-01 -0.81958916 0.20216281 703.25 1.32156589e-01 -8.97081673e-01 9.06763967e-01 -1.42453005 0.16851879 703.50 -1.16593192e+00 -3.67960915e-01 1.22261706e+00 -2.83589170 0.20331148 703.75 -1.74127085e+00 -2.52426781e-01 1.75947250e+00 -2.99762857 0.25087924 704.00 -3.72034011e+00 6.14334323e-01 3.77072105e+00 2.97794091 0.63362616 704.25 -4.05481823e+00 1.23307742e+00 4.23816361e+00 2.84637702 0.68291453 704.50 -3.58415699e+00 1.36947053e+00 3.83687775e+00 2.77662063 0.67471365 704.75 -3.58295697e+00 1.58985845e+00 3.91985083e+00 2.72396672 0.62895445 705.00 -4.05685681e+00 2.04480482e+00 4.54305117e+00 2.67472088 0.62618348 705.25 -4.08539075e+00 2.45879647e+00 4.76823842e+00 2.59981324 0.63722694 705.50 -3.94293905e+00 2.89632354e+00 4.89238780e+00 2.50804689 0.79689188 705.75 -3.84021792e+00 3.12545558e+00 4.95133782e+00 2.45844870 0.83512513 706.00 -3.82479045e+00 3.42072781e+00 5.13131569e+00 2.41190404 0.88608039 706.25 -3.83789847e+00 3.39030002e+00 5.12089825e+00 2.41803945 0.89352494 706.50 -4.37457664e+00 3.32009188e+00 5.49180579e+00 2.49238710 0.91915886 706.75 -4.68181779e+00 3.57653582e+00 5.89160643e+00 2.48924189 0.92445170 707.00 -5.16287696e+00 3.77734556e+00 6.39715858e+00 2.50994861 0.93446576 707.25 -5.40481155e+00 4.29295057e+00 6.90227590e+00 2.47034735 0.91504278 707.50 -5.84702301e+00 4.72043603e+00 7.51466529e+00 2.46240240 0.93552894 707.75 -6.21007308e+00 5.35375622e+00 8.19925078e+00 2.43011090 0.92337686 708.00 -6.66896668e+00 5.71683544e+00 8.78392418e+00 2.43291640 0.94247959 708.25 -7.10689954e+00 6.43728861e+00 9.58888449e+00 2.40559326 0.92668775 708.50 -7.16275354e+00 6.97781657e+00 9.99974812e+00 2.36927221 0.94232169 708.75 -7.39042942e+00 7.60123229e+00 1.06017536e+01 2.34213408 0.92228763 709.00 -7.65689503e+00 8.58028227e+00 1.14999689e+01 2.29938697 0.94450939 709.25 -8.11991897e+00 9.85055156e+00 1.27658314e+01 2.26018632 0.94451706 709.50 -8.10315022e+00 1.06345103e+01 1.33698860e+01 2.22191268 0.96100747 709.75 -7.61309447e+00 1.22599289e+01 1.44313916e+01 2.12649515 0.96549370 710.00 -7.34096308e+00 1.33023861e+01 1.51935255e+01 2.07506115 0.97443002 710.25 -6.84625077e+00 1.42538184e+01 1.58127319e+01 2.01856818 0.97562935 710.50 -6.67267515e+00 1.50180775e+01 1.64337228e+01 1.98890800 0.97909760 710.75 -5.90255352e+00 1.63214985e+01 1.73560206e+01 1.91780552 0.97405770 711.00 -5.27403237e+00 1.71291758e+01 1.79227253e+01 1.86948280 0.98461913 711.25 -3.88377672e+00 1.86896059e+01 1.90888734e+01 1.77568444 0.97000008 711.50 -2.29638969e+00 1.95396977e+01 1.96741758e+01 1.68778401 0.97433892 711.75 -3.69274607e-01 1.95723936e+01 1.95758769e+01 1.58966120 0.96878591 712.00 1.06364909e+00 1.95317037e+01 1.95606442e+01 1.51639250 0.97538420 712.25 2.67755729e+00 1.88057918e+01 1.89954499e+01 1.42936749 0.98371384 712.50 3.45724922e+00 1.79389939e+01 1.82691017e+01 1.38040798 0.97756107 712.75 4.35552778e+00 1.61187746e+01 1.66968715e+01 1.30688451 0.97395844 713.00 4.69907196e+00 1.53611905e+01 1.60638554e+01 1.27393053 0.97856316 713.25 4.56647184e+00 1.44168952e+01 1.51228150e+01 1.26404930 0.97939085 713.50 4.37275282e+00 1.38532954e+01 1.45270355e+01 1.26504690 0.97633618 713.75 3.88949715e+00 1.29090251e+01 1.34822519e+01 1.27814674 0.97343371 714.00 3.60236738e+00 1.26470940e+01 1.31501345e+01 1.29330742 0.97227179 714.25 2.45832019e+00 1.23542333e+01 1.25964447e+01 1.37437590 0.97324830 714.50 1.63617341e+00 1.22262951e+01 1.23352890e+01 1.43776259 0.97060800 714.75 1.85077615e-03 1.15387962e+01 1.15387964e+01 1.57063593 0.96051267 715.00 -1.02275597e+00 1.15337902e+01 1.15790478e+01 1.65923974 0.94690464 715.25 -2.42745561e+00 1.15606256e+01 1.18127306e+01 1.77776567 0.94835900 715.50 -3.22800643e+00 1.15705006e+01 1.20123482e+01 1.84286440 0.94454595 715.75 -4.82602528e+00 1.16864695e+01 1.26437372e+01 1.96242355 0.91117282 716.00 -5.74287452e+00 1.16681810e+01 1.30048859e+01 2.02817040 0.88049741 716.25 -7.74534400e+00 1.21132912e+01 1.43778363e+01 2.13968994 0.87043796 716.50 -8.44053434e+00 1.19108833e+01 1.45983479e+01 2.18729778 0.82651520 716.75 -1.17456525e+01 1.22915805e+01 1.70012736e+01 2.33348663 0.83197554 717.00 -1.15871130e+01 1.15505367e+01 1.63608095e+01 2.35777530 0.77206580 717.25 -1.42886892e+01 8.35500138e+00 1.65521204e+01 2.61247801 0.64733028 717.50 -1.56376851e+01 4.31603791e+00 1.62223727e+01 2.87229480 0.48202514 717.75 -1.93434100e+01 -2.36944199e+00 1.94879903e+01 -3.01970635 0.44231992 718.00 -2.09654955e+01 -5.19298496e+00 2.15990530e+01 -2.89878743 0.32208770 718.25 -2.57973495e+01 -6.19934682e+00 2.65317761e+01 -2.90575510 0.29051623 718.50 -4.42018777e-01 -4.58637335e+00 4.60762424e+00 -1.66687612 0.01161394 718.75 1.13003906e+01 -4.28096365e+00 1.20841002e+01 -0.36212708 0.12758750 719.00 1.32358913e+01 -5.70077809e+00 1.44113736e+01 -0.40669376 0.19474875 719.25 1.38746499e+01 -4.24656451e+00 1.45099697e+01 -0.29701299 0.15899881 719.50 1.65766983e+01 6.63725908e-01 1.65899807e+01 0.04001832 0.26557615 719.75 1.56868449e+01 4.70862283e+00 1.63782853e+01 0.29160706 0.34081303 720.00 1.46308394e+01 1.28878570e+01 1.94976491e+01 0.72214454 0.51035300 720.25 1.28949506e+01 1.47542406e+01 1.95950853e+01 0.85254281 0.55447119 720.50 7.90323321e+00 9.65334569e+00 1.24759039e+01 0.88475407 0.37952461 720.75 4.23363299e+00 7.92335510e+00 8.98349622e+00 1.08006861 0.27298713 721.00 7.28914890e-02 7.22357621e+00 7.22394397e+00 1.56070589 0.26367447 721.25 -6.90203197e-01 5.97386605e+00 6.01360591e+00 1.68582342 0.25271208 721.50 -2.62379505e+00 1.83240229e-01 2.63018582e+00 3.07186800 0.05070135 721.75 -4.17266195e+00 -1.46673853e+00 4.42294356e+00 -2.80357195 0.14101066 722.00 -1.40336038e+00 -4.72812834e+00 4.93199939e+00 -1.85932485 0.17885211 722.25 2.90972520e-01 -5.39000743e+00 5.39785561e+00 -1.51686498 0.16391024 722.50 1.45626174e+00 -4.45316908e+00 4.68523352e+00 -1.25474126 0.17431396 722.75 3.60178073e+00 -3.69692172e+00 5.16140045e+00 -0.79843275 0.20282392 723.00 6.28976941e+00 -2.13770951e+00 6.64311683e+00 -0.32762277 0.22025115 723.25 8.14613905e+00 -1.17922355e+00 8.23104791e+00 -0.14375997 0.31604190 723.50 7.27399026e+00 2.74873791e+00 7.77602047e+00 0.36129832 0.20430530 723.75 4.96537871e+00 6.57974797e+00 8.24306187e+00 0.92432857 0.21224896 724.00 2.60000372e+00 6.15965746e+00 6.68591051e+00 1.17138287 0.19162995 724.25 8.40220908e-01 5.64699035e+00 5.70915679e+00 1.42308906 0.13850185 724.50 -7.15205467e-01 6.18798508e+00 6.22917958e+00 1.68586545 0.16938562 724.75 7.29295682e-02 6.29702933e+00 6.29745164e+00 1.55921526 0.20066460 725.00 -2.20674695e+00 5.96599142e+00 6.36103653e+00 1.92507748 0.27646561 725.25 -3.77188606e+00 4.69226459e+00 6.02033815e+00 2.24788161 0.30261763 725.50 -4.04668927e+00 2.48808923e+00 4.75039809e+00 2.59032870 0.17767078 725.75 -4.50906172e+00 1.98924960e+00 4.92836195e+00 2.72610842 0.14789750 726.00 -4.68402288e+00 1.22837007e+00 4.84241297e+00 2.88512120 0.13849159 726.25 -4.76731817e+00 1.79837901e+00 5.09524186e+00 2.78086769 0.25840671 726.50 -5.17875444e+00 7.48871737e-01 5.23261947e+00 2.99798351 0.31115670 726.75 -4.65455446e+00 -1.27550243e+00 4.82615620e+00 -2.87412550 0.23719282 727.00 -2.93084365e+00 -1.74868853e+00 3.41288090e+00 -2.60363986 0.14946146 727.25 -2.31628731e+00 -3.70671846e-01 2.34575884e+00 -2.98290966 0.08050444 727.50 -1.40009106e+00 -8.26269989e-01 1.62572355e+00 -2.60844397 0.04700033 727.75 -1.25243562e+00 -5.11609678e-01 1.35290039e+00 -2.75378727 0.04533020 728.00 -5.16846323e-01 2.97573553e-01 5.96389253e-01 2.61919595 0.01181574 728.25 -2.50425440e-01 4.35776852e-01 5.02607566e-01 2.09237835 0.00735569 728.50 -9.50879497e-01 -3.27167331e-01 1.00558952e+00 -2.81021209 0.04001986 728.75 -1.66490387e+00 1.05659277e+00 1.97187555e+00 2.57610056 0.15406793 729.00 -2.52735554e+00 2.42020063e+00 3.49927094e+00 2.37784925 0.39651716 729.25 -2.69701517e+00 2.57082936e+00 3.72599711e+00 2.38014388 0.33533804 729.50 -2.82580017e+00 3.42774147e+00 4.44235952e+00 2.26023406 0.37011580 729.75 -1.36639060e+00 5.34194442e+00 5.51392723e+00 1.82121248 0.51143786 730.00 -8.12380416e-01 5.86333126e+00 5.91934248e+00 1.70847252 0.47475121 730.25 1.09045446e+00 4.57866233e+00 4.70672282e+00 1.33699181 0.40530170 730.50 1.31725154e+00 5.00137320e+00 5.17193247e+00 1.31326680 0.57219561 730.75 1.05238721e+00 5.30659562e+00 5.40994232e+00 1.37501972 0.58949149 731.00 3.03453931e-01 5.47218185e+00 5.48058925e+00 1.51539915 0.58067395 731.25 5.88109056e-01 5.43018272e+00 5.46193708e+00 1.46291310 0.60169326 731.50 9.53848130e-01 4.99600303e+00 5.08624346e+00 1.38214442 0.47807731 731.75 7.10543072e-01 3.72267249e+00 3.78987624e+00 1.38219572 0.31520358 732.00 1.43134460e-01 3.30279675e+00 3.30589683e+00 1.52748608 0.27860880 732.25 5.49976052e-01 2.88258922e+00 2.93458588e+00 1.38226972 0.23220790 732.50 5.67761978e-01 2.60241908e+00 2.66363262e+00 1.35599507 0.20334365 732.75 6.97649379e-01 1.45395399e+00 1.61266763e+00 1.12341529 0.08692595 733.00 7.75141067e-01 1.09361054e+00 1.34045802e+00 0.95419484 0.06745678 733.25 1.53996556e+00 6.93778544e-01 1.68903007e+00 0.42328264 0.11132343 733.50 9.48741882e-01 7.34329821e-01 1.19972974e+00 0.65868739 0.04630330 733.75 -6.77881615e-02 1.32007897e+00 1.32181834e+00 1.62210286 0.06719569 734.00 -8.33120343e-01 1.52272314e+00 1.73573479e+00 2.07142979 0.10194306 734.25 -2.06222055e+00 5.70976422e-01 2.13980552e+00 2.87148451 0.11522668 734.50 -1.43965605e+00 6.01869388e-01 1.56040261e+00 2.74561089 0.05614938 734.75 2.61586478e-01 1.32402176e+00 1.34961517e+00 1.37573876 0.01948518 735.00 1.64926834e+00 1.83742873e+00 2.46905455e+00 0.83931109 0.05542761 735.25 4.64448152e+00 2.44259817e+00 5.24761798e+00 0.48416330 0.23763078 735.50 5.21695021e+00 4.23783844e-01 5.23413434e+00 0.08105413 0.24368573 735.75 5.77856800e+00 -5.94903383e+00 8.29354277e+00 -0.79993258 0.34662758 736.00 6.70960101e+00 -7.66841225e+00 1.01893715e+01 -0.85198551 0.42025531 736.25 7.43248802e+00 -8.84296287e+00 1.15516177e+01 -0.87184490 0.54281618 736.50 6.60343080e+00 -1.02667011e+01 1.22069837e+01 -0.99922396 0.57911241 736.75 2.50380092e+00 -1.12921630e+01 1.15664153e+01 -1.35259736 0.43628828 737.00 2.57887966e+00 -1.08960537e+01 1.11970803e+01 -1.33839274 0.40918995 737.25 4.37860403e+00 -1.02946702e+01 1.11871537e+01 -1.16864851 0.39463109 737.50 4.76396705e+00 -8.33465561e+00 9.60009720e+00 -1.05153203 0.41437251 737.75 5.70565411e+00 -7.13191416e+00 9.13338319e+00 -0.89604489 0.34238326 738.00 6.87521168e+00 -6.39800600e+00 9.39164609e+00 -0.74946112 0.38781300 738.25 8.48746414e+00 -5.46843151e+00 1.00965732e+01 -0.57235428 0.47521073 738.50 7.19003276e+00 -2.79658555e+00 7.71475610e+00 -0.37094707 0.37449075 738.75 3.62669561e+00 -2.25528396e-01 3.63370116e+00 -0.06210567 0.12085545 739.00 3.94504347e+00 1.00888957e+00 4.07200517e+00 0.25036991 0.11802042 739.25 6.34097471e+00 1.92732085e+00 6.62740718e+00 0.29507404 0.28271466 739.50 6.93491327e+00 3.42252338e-01 6.94335356e+00 0.04931206 0.40273702 739.75 6.43038455e+00 1.08021559e+00 6.52048397e+00 0.16643223 0.47231065 740.00 3.85388421e+00 2.87016191e-01 3.86455713e+00 0.07433729 0.21383996 740.25 2.87769109e+00 -4.83758315e-03 2.87769515e+00 -0.00168106 0.14332074 740.50 3.90417237e+00 -3.39710040e-01 3.91892394e+00 -0.08679345 0.30567393 740.75 3.48156035e+00 -3.92559906e-01 3.50362180e+00 -0.11227980 0.41862875 741.00 3.27797306e+00 -9.87457940e-02 3.27946004e+00 -0.03011493 0.34378441 741.25 3.26798836e+00 -2.64614878e-01 3.27868403e+00 -0.08079552 0.30929242 741.50 2.24954618e+00 -3.84844028e-02 2.24987535e+00 -0.01710596 0.21009061 741.75 1.98548087e+00 3.23271366e-02 1.98574402e+00 0.01628033 0.28124227 742.00 2.04696323e+00 -8.81524870e-01 2.22870917e+00 -0.40664656 0.27814134 742.25 1.35206752e+00 -1.02371600e+00 1.69590124e+00 -0.64806052 0.11589014 742.50 1.65168333e+00 -8.83662030e-01 1.87321019e+00 -0.49125939 0.06230309 742.75 1.15398489e+00 -1.38758385e+00 1.80473546e+00 -0.87705199 0.04541555 743.00 -5.89984350e-01 1.43798249e+00 1.55430858e+00 1.96013853 0.02540507 743.25 -1.69994088e+00 3.29410051e+00 3.70687161e+00 2.04720621 0.14764769 743.50 -2.40334641e+00 2.18354255e+00 3.24714214e+00 2.40407789 0.17017360 743.75 -2.16472234e+00 2.04209946e+00 2.97593565e+00 2.38533482 0.21193482 744.00 -1.62054237e+00 2.46182704e+00 2.94732929e+00 2.15296202 0.29181269 744.25 -1.52034298e+00 2.52832579e+00 2.95023289e+00 2.11218879 0.29567492 744.50 -1.55411853e+00 2.27721384e+00 2.75698881e+00 2.16965657 0.32118893 744.75 -1.82169611e+00 2.27559678e+00 2.91494724e+00 2.24586373 0.44269130 745.00 -2.17491539e+00 2.58091185e+00 3.37510932e+00 2.27103276 0.66314022 745.25 -2.06775731e+00 2.58655364e+00 3.31147701e+00 2.24518695 0.68580696 745.50 -1.84557853e+00 2.38006325e+00 3.01178704e+00 2.23037658 0.61332115 745.75 -1.93511882e+00 2.38764888e+00 3.07336168e+00 2.25188915 0.65861162 746.00 -1.80121321e+00 2.88719094e+00 3.40297525e+00 2.12857801 0.74514129 746.25 -1.65750448e+00 2.75111368e+00 3.21184488e+00 2.11304096 0.75453463 746.50 -1.42796839e+00 2.53961971e+00 2.91354801e+00 2.08301596 0.70620757 746.75 -1.38498469e+00 2.41619878e+00 2.78499535e+00 2.09128290 0.64255299 747.00 -1.78527251e+00 2.37803477e+00 2.97359165e+00 2.21476729 0.63257535 747.25 -1.88236059e+00 2.43236211e+00 3.07565714e+00 2.22940737 0.60479910 747.50 -1.75088108e+00 2.66542187e+00 3.18905289e+00 2.15199782 0.62675182 747.75 -1.53665199e+00 2.66102417e+00 3.07284054e+00 2.09448218 0.56120867 748.00 -1.36716488e+00 2.63717385e+00 2.97049251e+00 2.04907147 0.58852864 748.25 -1.12911043e+00 2.48620584e+00 2.73058782e+00 1.99709605 0.47910549 748.50 -6.02785182e-01 2.20410349e+00 2.28504314e+00 1.83775180 0.35513540 748.75 -8.39695913e-01 1.85540009e+00 2.03656543e+00 1.99578429 0.25863047 749.00 -8.76108453e-01 1.23888683e+00 1.51736831e+00 2.18632079 0.15177272 749.25 -1.00486387e+00 4.90100983e-01 1.11801180e+00 2.68781016 0.06888772 749.50 -1.02779266e+00 -9.52833966e-01 1.40151715e+00 -2.39402239 0.08196165 749.75 -9.71394207e-01 -1.61264355e+00 1.88261147e+00 -2.11295033 0.14109798 750.00 -2.65288922e+00 -1.96466513e+00 3.30117105e+00 -2.50415047 0.31761163 750.25 -4.61332527e+00 3.09555927e-01 4.62369927e+00 3.07459270 0.44734218 750.50 -6.20006582e+00 3.77840980e-01 6.21156824e+00 3.08072648 0.68552278 750.75 -5.78376323e+00 4.30612647e-01 5.79977106e+00 3.06727778 0.56478733 751.00 -3.82851077e+00 4.95877480e-01 3.86049079e+00 3.01278745 0.28444345 751.25 -4.58051023e+00 1.77378995e+00 4.91196546e+00 2.77212814 0.43882750 751.50 -5.33605342e+00 2.73776846e+00 5.99740296e+00 2.66754387 0.53461421 751.75 -4.83761876e+00 4.51864749e+00 6.61972283e+00 2.39027302 0.57881789 752.00 -4.10817677e+00 5.73013374e+00 7.05064175e+00 2.19280287 0.63875769 752.25 -3.01218925e+00 5.27973319e+00 6.07855794e+00 2.08925666 0.56344659 752.50 -2.72824703e+00 5.08849164e+00 5.77374047e+00 2.06295197 0.50005398 752.75 -2.77237419e+00 4.54007253e+00 5.31961627e+00 2.11900654 0.54224225 753.00 -2.43209410e+00 4.20396199e+00 4.85678681e+00 2.09527517 0.50542391 753.25 -1.74532930e+00 2.79599707e+00 3.29602397e+00 2.12883764 0.21623086 753.50 -1.16724711e+00 2.26545341e+00 2.54847895e+00 2.04655969 0.15550785 753.75 -1.48835499e+00 2.23204634e+00 2.68276563e+00 2.15889945 0.18982723 754.00 -1.83589296e+00 2.22026224e+00 2.88098375e+00 2.26171464 0.24780158 754.25 -1.46938042e+00 1.84654929e+00 2.35983540e+00 2.24293672 0.15239118 754.50 -1.80163794e+00 1.33989040e+00 2.24526291e+00 2.50213137 0.16097052 754.75 -2.67789498e+00 1.45296415e+00 3.04667464e+00 2.64446636 0.39653955 755.00 -3.34207317e+00 1.05020939e+00 3.50319752e+00 2.83712438 0.49441451 755.25 -4.74085815e+00 1.81246661e+00 5.07550699e+00 2.77643067 0.59597754 755.50 -5.03660658e+00 2.34606936e+00 5.55620799e+00 2.70567447 0.54923199 755.75 -5.50008080e+00 3.48915961e+00 6.51345711e+00 2.57627421 0.46843330 756.00 -4.99784581e+00 3.78451693e+00 6.26905345e+00 2.49348062 0.39153772 756.25 -4.35816343e+00 5.03759163e+00 6.66114990e+00 2.28400789 0.35701679 756.50 -3.09703196e+00 4.71458892e+00 5.64082934e+00 2.15200962 0.19231724 756.75 3.08609690e+00 4.38719945e-01 3.11712516e+00 0.14121392 0.04579819 757.00 5.27441040e+00 5.02069645e-01 5.29825245e+00 0.09490376 0.17955685 757.25 4.58635388e+00 1.19528193e+00 4.73955070e+00 0.25494593 0.20448350 757.50 6.63001796e+00 -7.27838636e-02 6.63041745e+00 -0.01097749 0.39111043 757.75 8.25191417e+00 -5.95149781e-01 8.27334822e+00 -0.07199797 0.57249167 758.00 7.94294835e+00 2.10504693e-01 7.94573727e+00 0.02649588 0.62089649 758.25 7.88608134e+00 1.16872531e+00 7.97221411e+00 0.14713009 0.78952528 758.50 6.97617984e+00 8.47598903e-01 7.02748241e+00 0.12090639 0.81092788 758.75 7.05838371e+00 1.01289672e+00 7.13069004e+00 0.14252959 0.89080436 759.00 7.15210342e+00 1.20419175e+00 7.25276920e+00 0.16680444 0.90400879 759.25 7.50372872e+00 1.35388450e+00 7.62489003e+00 0.17850770 0.92167671 759.50 7.25939628e+00 1.13363873e+00 7.34737852e+00 0.15491042 0.92609744 759.75 7.25577218e+00 7.45935880e-01 7.29401469e+00 0.10244595 0.94358140 760.00 7.10815698e+00 1.86975677e-01 7.11061570e+00 0.02629832 0.91658371 760.25 6.85871398e+00 -6.42081692e-01 6.88870281e+00 -0.09334342 0.92096538 760.50 6.16568223e+00 -8.95786983e-01 6.23041505e+00 -0.14427647 0.92088069 760.75 5.72539884e+00 -1.40895910e+00 5.89621553e+00 -0.24129458 0.92035893 761.00 5.27087906e+00 -1.24707571e+00 5.41639769e+00 -0.23232512 0.91185713 761.25 4.74451892e+00 -9.92028449e-01 4.84712082e+00 -0.20611986 0.90600671 761.50 4.32156375e+00 -1.14303015e+00 4.47017127e+00 -0.25857341 0.89202341 761.75 4.01651043e+00 -1.20455898e+00 4.19324676e+00 -0.29136676 0.87474034 762.00 3.57018533e+00 -1.14309182e+00 3.74871741e+00 -0.30986365 0.82375492 762.25 3.15359380e+00 -1.25684228e+00 3.39482052e+00 -0.37924959 0.81597071 762.50 2.84564425e+00 -9.63377647e-01 3.00429487e+00 -0.32643339 0.79721397 762.75 2.54197641e+00 -6.20799019e-01 2.61668407e+00 -0.23953040 0.77990158 763.00 2.75620890e+00 -2.45275317e-01 2.76710092e+00 -0.08875630 0.83433518 763.25 2.82541632e+00 -2.91845430e-02 2.82556704e+00 -0.01032892 0.84495793 763.50 3.06111114e+00 8.43040923e-03 3.06112274e+00 0.00275403 0.89525641 763.75 3.07831467e+00 -3.60934967e-02 3.07852626e+00 -0.01172455 0.91669807 764.00 2.96608693e+00 -5.68746429e-03 2.96609238e+00 -0.00191750 0.92113720 764.25 2.93491381e+00 -2.39867441e-02 2.93501183e+00 -0.00817271 0.91497448 764.50 2.84364319e+00 -3.97471308e-02 2.84392096e+00 -0.01397663 0.93046262 764.75 2.86384713e+00 9.99636165e-02 2.86559123e+00 0.03489119 0.94487713 765.00 3.07436719e+00 3.63235721e-02 3.07458176e+00 0.01181443 0.95973541 765.25 2.99889116e+00 -8.31508478e-02 3.00004371e+00 -0.02772010 0.96600259 765.50 2.77910412e+00 -7.24729744e-02 2.78004892e+00 -0.02607191 0.94372840 765.75 2.75041029e+00 -9.71643380e-02 2.75212603e+00 -0.03531253 0.92956321 766.00 2.43142028e+00 -1.62729449e-01 2.43685975e+00 -0.06682807 0.91222150 766.25 2.32745262e+00 -8.68380202e-02 2.32907204e+00 -0.03729303 0.90557283 766.50 2.41178825e+00 2.01682907e-01 2.42020631e+00 0.08342969 0.89221363 766.75 2.48025535e+00 2.65962005e-01 2.49447437e+00 0.10682351 0.91457671 767.00 2.53527075e+00 3.75734426e-01 2.56296198e+00 0.14713191 0.93250562 767.25 2.61755452e+00 4.53425408e-01 2.65653651e+00 0.17152272 0.95469693 767.50 2.92514982e+00 3.95276346e-01 2.95173591e+00 0.13431668 0.95449926 767.75 3.06623941e+00 2.76998430e-01 3.07872575e+00 0.09009361 0.94762312 768.00 3.06487180e+00 3.81869975e-01 3.08856986e+00 0.12395694 0.93943615 768.25 3.16530649e+00 5.08566602e-01 3.20590161e+00 0.15930749 0.92494901 768.50 3.62586804e+00 2.47635046e-01 3.63431454e+00 0.06819087 0.90078938 768.75 3.80252946e+00 1.07874289e-01 3.80405930e+00 0.02836148 0.89328278 769.00 3.70492041e+00 -2.83036009e-02 3.70502852e+00 -0.00763931 0.85693247 769.25 3.70584661e+00 -8.23119521e-02 3.70676063e+00 -0.02220772 0.82332751 769.50 3.55314134e+00 -3.17210129e-01 3.56727286e+00 -0.08903991 0.75043958 769.75 3.30466067e+00 -7.08984917e-01 3.37985825e+00 -0.21133732 0.74044191 770.00 3.16613950e+00 -8.64546386e-01 3.28205420e+00 -0.26656181 0.64485645 770.25 3.14519914e+00 -1.24545264e+00 3.38281390e+00 -0.37704065 0.49359382 770.50 2.79763891e+00 -1.97692918e+00 3.42564336e+00 -0.61516979 0.38670161 770.75 2.13362726e+00 -2.75685056e+00 3.48605655e+00 -0.91215103 0.43454924 771.00 1.57892015e+00 -2.85596600e+00 3.26336186e+00 -1.06576783 0.50766296 771.25 1.26652979e+00 -2.28285836e+00 2.61065892e+00 -1.06427538 0.41852959 771.50 1.23062429e+00 -2.11633082e+00 2.44812015e+00 -1.04409864 0.41873452 771.75 1.13025720e+00 -1.78128196e+00 2.10960820e+00 -1.00538117 0.39534024 772.00 1.48003849e+00 -1.72983682e+00 2.27658721e+00 -0.86306345 0.53644722 772.25 1.06140820e+00 -2.07966321e+00 2.33486326e+00 -1.09888317 0.69632213 772.50 8.06370268e-01 -2.13820673e+00 2.28520481e+00 -1.21016433 0.67050864 772.75 5.62251004e-01 -1.82704888e+00 1.91160504e+00 -1.27225634 0.64301536 773.00 6.47106448e-01 -1.91112121e+00 2.01770440e+00 -1.24431291 0.65715267 773.25 4.04846351e-01 -1.78233681e+00 1.82773769e+00 -1.34744254 0.63034668 773.50 2.66850171e-01 -1.55725386e+00 1.57995209e+00 -1.40108520 0.57045657 773.75 4.18089739e-01 -1.08337263e+00 1.16124730e+00 -1.20249085 0.42766491 774.00 5.38841924e-01 -1.04069349e+00 1.17191875e+00 -1.09303243 0.44183627 774.25 6.14671116e-01 -7.44934546e-01 9.65788827e-01 -0.88091632 0.36749445 774.50 6.96804747e-01 -6.10928878e-01 9.26698953e-01 -0.71982460 0.33045949 774.75 1.06261908e+00 -6.82018509e-01 1.26265932e+00 -0.57060882 0.45826783 775.00 1.26781945e+00 -8.33401267e-01 1.51720923e+00 -0.58152492 0.52724800 775.25 1.45683259e+00 -9.02944833e-01 1.71396341e+00 -0.55485124 0.51785813 775.50 1.65576904e+00 -9.97911989e-01 1.93323549e+00 -0.54239356 0.61895585 775.75 1.62026100e+00 -1.38501227e+00 2.13154984e+00 -0.70727882 0.76904252 776.00 1.69754440e+00 -1.51827092e+00 2.27745550e+00 -0.72970836 0.80770433 776.25 1.78906655e+00 -2.06938964e+00 2.73553151e+00 -0.85792236 0.84739635 776.50 1.54867784e+00 -2.31733198e+00 2.78719044e+00 -0.98166235 0.85109370 776.75 1.17292264e+00 -2.39787881e+00 2.66937639e+00 -1.11586626 0.78364781 777.00 9.48530454e-01 -2.56862670e+00 2.73816602e+00 -1.21705397 0.83526444 777.25 7.62620362e-01 -2.77629112e+00 2.87912872e+00 -1.30271802 0.83030943 777.50 4.44015299e-01 -2.90824111e+00 2.94194085e+00 -1.41929141 0.82633836 777.75 8.02892598e-02 -2.59135592e+00 2.59259944e+00 -1.53982274 0.82148861 778.00 -1.43661568e-01 -2.24953373e+00 2.25411638e+00 -1.63457254 0.79811441 778.25 -2.65223153e-01 -1.77134610e+00 1.79109194e+00 -1.71942193 0.73833579 778.50 -2.20201520e-01 -1.59152341e+00 1.60668462e+00 -1.70828241 0.76262041 778.75 -1.70615964e-01 -1.45155655e+00 1.46154926e+00 -1.68779948 0.71298385 779.00 -1.72980926e-01 -1.60368505e+00 1.61298734e+00 -1.67824555 0.73591952 779.25 -2.52220367e-01 -1.68927442e+00 1.70799976e+00 -1.71900838 0.69641271 779.50 -3.84225565e-01 -1.65441879e+00 1.69844954e+00 -1.79899305 0.77301218 779.75 -5.87223069e-01 -1.68884580e+00 1.78802435e+00 -1.90542669 0.86456438 780.00 -7.49742507e-01 -1.51315726e+00 1.68871511e+00 -2.03082318 0.84734282 780.25 -1.08347008e+00 -1.08185676e+00 1.53111772e+00 -2.35693956 0.77161918 780.50 -8.88521851e-01 -7.80231329e-01 1.18246861e+00 -2.42099670 0.75351418 780.75 -6.62529825e-01 -5.65940542e-01 8.71340614e-01 -2.43465872 0.70518973 781.00 -4.29002794e-01 -5.45267511e-01 6.93801165e-01 -2.23742100 0.47387879 781.25 -2.22617897e-01 -9.33560904e-01 9.59736781e-01 -1.80488565 0.62047015 781.50 -2.86343781e-01 -1.15029614e+00 1.18540034e+00 -1.81476814 0.77350300 781.75 -4.10626961e-01 -1.32536546e+00 1.38751869e+00 -1.87123931 0.84654489 782.00 -6.78234099e-01 -1.31851391e+00 1.48272736e+00 -2.04589179 0.83989341 782.25 -8.98190604e-01 -1.21158085e+00 1.50820241e+00 -2.20873050 0.88398890 782.50 -1.04326310e+00 -1.05173607e+00 1.48140024e+00 -2.35215013 0.88112342 782.75 -1.15255473e+00 -8.80472504e-01 1.45038417e+00 -2.48923504 0.86024276 783.00 -1.14528998e+00 -6.62311664e-01 1.32300638e+00 -2.61728811 0.86004830 783.25 -1.12424719e+00 -5.85607910e-01 1.26762311e+00 -2.66137389 0.81755885 783.50 -1.12640443e+00 -3.95471921e-01 1.19381112e+00 -2.80394507 0.77217088 783.75 -1.15304408e+00 -2.66161948e-01 1.18336505e+00 -2.91473217 0.77790012 784.00 -1.21328464e+00 -1.37092064e-01 1.22100526e+00 -3.02907737 0.81959747 784.25 -1.10743731e+00 5.73230830e-02 1.10891990e+00 3.08987689 0.77894118 784.50 -8.44433754e-01 2.92018500e-01 8.93500514e-01 2.80865029 0.72700812 784.75 -7.39869514e-01 4.11812117e-01 8.46756233e-01 2.63369562 0.69329662 785.00 -6.34616953e-01 4.35160828e-01 7.69482698e-01 2.54052435 0.69853914 785.25 -5.42146763e-01 4.41149590e-01 6.98953556e-01 2.45854841 0.63510911 785.50 -3.25599738e-01 4.37031636e-01 5.44987927e-01 2.21110618 0.55989487 785.75 -2.34109193e-01 3.66189006e-01 4.34628005e-01 2.13962161 0.37572906 786.00 -1.60064922e-01 2.93121312e-01 3.33977369e-01 2.07061770 0.36323611 786.25 -1.24661882e-01 2.97979092e-01 3.23004836e-01 1.96702756 0.34582399 786.50 -8.03452485e-02 9.01458602e-02 1.20754441e-01 2.29877309 0.05704769 786.75 -9.24758953e-02 4.80477276e-02 1.04213125e-01 2.66241167 0.05453748 787.00 -1.97385650e-02 9.03948658e-03 2.17099808e-02 2.71213838 0.00239640 787.25 -6.12396421e-02 -1.71901289e-03 6.12637639e-02 -3.11352976 0.01667437 787.50 -1.08760101e-01 -8.78102422e-03 1.09114004e-01 -3.06102985 0.06223620 787.75 -8.50859516e-02 -5.01598205e-02 9.87705763e-02 -2.60891511 0.06184824 788.00 -1.88200901e-01 -6.98598203e-02 2.00748533e-01 -2.78615930 0.22654444 788.25 -2.36894073e-01 -2.29467450e-02 2.38002847e-01 -3.04502891 0.25409866 788.50 -2.20485349e-01 2.28741282e-02 2.21668705e-01 3.03821803 0.26797509 788.75 -2.04611308e-01 7.24632707e-02 2.17063845e-01 2.80122476 0.25146689 789.00 -1.67862328e-01 1.54478351e-01 2.28125672e-01 2.39769187 0.38858461 789.25 -9.77351845e-02 1.54412432e-01 1.82743989e-01 2.13509132 0.34536864 789.50 -8.70355970e-02 2.16584074e-01 2.33417772e-01 1.95290163 0.39913067 789.75 -5.35788744e-02 1.90799207e-01 1.98179296e-01 1.84455865 0.24663636 790.00 7.03573880e-02 2.04666165e-01 2.16421813e-01 1.23968542 0.31728007 790.25 1.71836651e-01 1.77281655e-01 2.46893944e-01 0.80099334 0.38400539 790.50 3.09318415e-01 4.90232422e-02 3.13179118e-01 0.15718061 0.49935560 790.75 3.21876363e-01 -1.19093142e-01 3.43201936e-01 -0.35437688 0.48156676 791.00 3.04164961e-01 -2.99193381e-01 4.26653258e-01 -0.77715850 0.61695848 791.25 2.27741200e-01 -4.28544741e-01 4.85300576e-01 -1.08232261 0.58579983 791.50 1.00822935e-01 -5.44420863e-01 5.53678011e-01 -1.38767795 0.65492946 791.75 -4.92107954e-02 -5.26748193e-01 5.29041928e-01 -1.66394970 0.57165387 792.00 -1.62920269e-01 -5.19633248e-01 5.44574813e-01 -1.87461868 0.68954954 792.25 -2.92925259e-01 -5.21318064e-01 5.97978035e-01 -2.08272498 0.71095936 792.50 -3.86259482e-01 -5.62091868e-01 6.82014410e-01 -2.17286779 0.78577060 792.75 -5.34087966e-01 -5.20430688e-01 7.45719824e-01 -2.36914496 0.75190031 793.00 -7.24261739e-01 -4.63094816e-01 8.59657999e-01 -2.57270341 0.84372641 793.25 -8.67445617e-01 -3.68557683e-01 9.42494914e-01 -2.73982620 0.86287908 793.50 -9.68119854e-01 -2.44767969e-01 9.98582701e-01 -2.89395396 0.87727967 793.75 -9.33183289e-01 2.78039795e-03 9.33187431e-01 3.13861319 0.83708196 794.00 -8.72714815e-01 1.16160213e-01 8.80411463e-01 3.00926828 0.85535246 794.25 -8.51465737e-01 1.98831161e-01 8.74372765e-01 2.91218717 0.87112162 794.50 -8.17055109e-01 2.37325580e-01 8.50824590e-01 2.85890673 0.88601441 794.75 -8.65247624e-01 2.87969014e-01 9.11909867e-01 2.82030698 0.87952274 795.00 -8.98141102e-01 2.81478632e-01 9.41216054e-01 2.83788684 0.89725218 795.25 -9.25600137e-01 4.53780484e-01 1.03085030e+00 2.68577105 0.88887161 795.50 -9.64590745e-01 5.69190355e-01 1.12000579e+00 2.60849563 0.89745108 795.75 -9.82719780e-01 8.19484450e-01 1.27956748e+00 2.44652339 0.86599844 796.00 -9.38105431e-01 9.41453930e-01 1.32905128e+00 2.35441296 0.85531983 796.25 -8.28295087e-01 1.20180264e+00 1.45958978e+00 2.17424430 0.86606328 796.50 -7.58435815e-01 1.37496259e+00 1.57026972e+00 2.07487071 0.89099003 796.75 -7.52646414e-01 1.48472563e+00 1.66459810e+00 2.03996958 0.85739537 797.00 -6.21185189e-01 1.58655558e+00 1.70382794e+00 1.94398031 0.84614886 797.25 -2.40431650e-01 1.82210552e+00 1.83789986e+00 1.70199105 0.87149793 797.50 -1.92276876e-01 1.91239008e+00 1.92203179e+00 1.67100228 0.83957548 797.75 7.61320012e-02 2.20817414e+00 2.20948616e+00 1.53633262 0.84386892 798.00 2.87532056e-01 2.30826520e+00 2.32610467e+00 1.44686838 0.85956746 798.25 8.14107364e-01 2.23401990e+00 2.37773332e+00 1.22133898 0.80828268 798.50 9.42900321e-01 2.09136175e+00 2.29409132e+00 1.14723184 0.78994411 798.75 1.39012366e+00 1.97866688e+00 2.41817419e+00 0.95835720 0.80034345 799.00 1.77786879e+00 2.13013846e+00 2.77458236e+00 0.87529569 0.81398690 799.25 1.97775062e+00 2.08225190e+00 2.87180613e+00 0.81113170 0.75446768 799.50 2.23733117e+00 1.78393704e+00 2.86148250e+00 0.67312328 0.63080617 799.75 3.21531284e+00 1.01270157e+00 3.37102375e+00 0.30512631 0.66481580 800.00 3.49929019e+00 4.72558054e-01 3.53105408e+00 0.13423191 0.55209805 800.25 4.67851381e+00 -1.07661494e+00 4.80079068e+00 -0.22618141 0.56260138 800.50 3.58163597e+00 -2.67413770e+00 4.46980186e+00 -0.64133738 0.47599127 800.75 2.30075198e+00 -4.25849045e+00 4.84026865e+00 -1.07545089 0.53154680 801.00 6.26861539e-01 -4.40188503e+00 4.44629589e+00 -1.42933993 0.48851707 801.25 -2.00695950e-01 -4.37255490e+00 4.37715835e+00 -1.61666315 0.67481309 801.50 -9.63844184e-01 -3.54990668e+00 3.67842807e+00 -1.83591739 0.76652317 801.75 -1.35330725e+00 -3.30442914e+00 3.57081117e+00 -1.95950263 0.85510599 802.00 -1.78625722e+00 -2.66647021e+00 3.20948255e+00 -2.16103116 0.85544061 802.25 -1.91616154e+00 -2.21098736e+00 2.92577172e+00 -2.28487992 0.89842162 802.50 -2.00316947e+00 -1.72114345e+00 2.64102683e+00 -2.43177589 0.89403111 802.75 -2.09355443e+00 -1.42749970e+00 2.53391506e+00 -2.54314891 0.92213181 803.00 -2.09207859e+00 -8.74203690e-01 2.26738283e+00 -2.74578201 0.87355549 803.25 -1.95634721e+00 -3.59978911e-01 1.98919060e+00 -2.95962252 0.88621125 803.50 -1.71918927e+00 -3.08538929e-02 1.71946612e+00 -3.12364781 0.84843390 803.75 -1.47534779e+00 2.69229053e-01 1.49971176e+00 2.96109361 0.83109568 804.00 -1.06066172e+00 4.15800442e-01 1.13925120e+00 2.76798459 0.78793930 804.25 -7.27275724e-01 5.17961179e-01 8.92868277e-01 2.52272980 0.74747220 804.50 -4.33736915e-01 5.47359090e-01 6.98376463e-01 2.24089665 0.71455989 804.75 -2.54865506e-01 5.31905665e-01 5.89813583e-01 2.01762969 0.63358588 805.00 7.16122597e-02 3.36551769e-01 3.44086340e-01 1.36114085 0.30221859 805.25 2.11007013e-01 2.08434869e-01 2.96595776e-01 0.77926594 0.27427162 805.50 5.67992785e-01 5.65689290e-02 5.70802810e-01 0.09926710 0.52290081 805.75 7.35178585e-01 -9.35667954e-02 7.41108830e-01 -0.12659027 0.64647159 806.00 9.32100830e-01 -4.75340885e-01 1.04630823e+00 -0.47158957 0.63193010 806.25 1.06984876e+00 -7.83507144e-01 1.32606931e+00 -0.63211115 0.63677982 806.50 1.30970966e+00 -1.59083465e+00 2.06060531e+00 -0.88201784 0.76286180 806.75 1.15382042e+00 -1.96147121e+00 2.27566933e+00 -1.03906702 0.79073552 807.00 6.37712294e-01 -2.48029985e+00 2.56096941e+00 -1.31913627 0.69824634 807.25 2.14132272e-01 -2.76610982e+00 2.77438573e+00 -1.49353762 0.66960754 807.50 -1.15399239e+00 -3.10015717e+00 3.30797111e+00 -1.92714221 0.75281824 807.75 -1.58601793e+00 -3.27766617e+00 3.64122897e+00 -2.02147012 0.80286066 808.00 -2.67218595e+00 -3.20832346e+00 4.17539425e+00 -2.26527391 0.83990454 808.25 -3.17870871e+00 -2.89929988e+00 4.30233993e+00 -2.40213260 0.87370309 808.50 -3.89169926e+00 -2.08490445e+00 4.41499147e+00 -2.64977039 0.76682953 808.75 -3.96346545e+00 -1.38396510e+00 4.19814456e+00 -2.80564803 0.73484501 809.00 -4.07939824e+00 -1.94243515e-01 4.08402014e+00 -3.09401286 0.75074691 809.25 -3.72395481e+00 1.16320489e-01 3.72577105e+00 3.11036706 0.69388666 809.50 -3.01950243e+00 8.80711199e-01 3.14532147e+00 2.85779153 0.60385550 809.75 -2.23536895e+00 1.43399266e+00 2.65578789e+00 2.57121495 0.54407325 810.00 -1.42517566e+00 1.63098235e+00 2.16592454e+00 2.28895437 0.56418185 810.25 -1.11403306e+00 1.26691338e+00 1.68705043e+00 2.29207262 0.49718588 810.50 -7.74188696e-01 1.01870326e+00 1.27950165e+00 2.22065073 0.49612897 810.75 -7.84820966e-01 7.66696224e-01 1.09716318e+00 2.36787591 0.42036987 811.00 -8.77723617e-01 4.54895508e-01 9.88599348e-01 2.66343818 0.43482104 811.25 -9.21362700e-01 4.43556882e-01 1.02257124e+00 2.69292411 0.47811118 811.50 -8.98376116e-01 4.88746893e-01 1.02271852e+00 2.64334162 0.54959864 811.75 -8.48996554e-01 5.76898218e-01 1.02645346e+00 2.54475390 0.51631942 812.00 -8.66791058e-01 5.96728537e-01 1.05233630e+00 2.53867128 0.56522594 812.25 -9.50376070e-01 4.90288051e-01 1.06939097e+00 2.66531522 0.62231757 812.50 -9.03099346e-01 4.11922418e-01 9.92606925e-01 2.71366032 0.63060328 812.75 -9.04822479e-01 4.91677197e-01 1.02978162e+00 2.64383359 0.65105513 813.00 -9.70078645e-01 4.41917023e-01 1.06599401e+00 2.71413491 0.72659340 813.25 -9.85432071e-01 4.63516188e-01 1.08900120e+00 2.70193000 0.70575435 813.50 -1.00604620e+00 4.65374827e-01 1.10846863e+00 2.70832824 0.78813566 813.75 -1.08848562e+00 5.10337087e-01 1.20218339e+00 2.70317366 0.78639330 814.00 -1.14719723e+00 5.15557319e-01 1.25772049e+00 2.71923281 0.78970369 814.25 -1.08443810e+00 4.75910538e-01 1.18427059e+00 2.72804589 0.62148388 814.50 -1.01050036e+00 4.44785565e-01 1.10405850e+00 2.72694865 0.54640519 814.75 -1.08367964e+00 4.68943523e-01 1.18079193e+00 2.73319069 0.61931237 815.00 -1.08012136e+00 5.41419744e-01 1.20822080e+00 2.67693895 0.68118623 815.25 -1.13407016e+00 6.50430217e-01 1.30735405e+00 2.62085920 0.62911662 815.50 -1.24334587e+00 7.82590766e-01 1.46913487e+00 2.57981892 0.61518370 815.75 -1.40358086e+00 1.00420524e+00 1.72582369e+00 2.52056638 0.57568722 816.00 -1.18229824e+00 1.08906151e+00 1.60744645e+00 2.39722032 0.44697573 816.25 -4.92761129e-01 1.36955295e+00 1.45550294e+00 1.91617224 0.40239247 816.50 -4.02911486e-01 1.45959784e+00 1.51418741e+00 1.84013177 0.44158046 816.75 -2.15671047e-01 5.11731201e-01 5.55322270e-01 1.96965946 0.09098289 817.00 -4.73559113e-02 -3.94942992e-02 6.16634576e-02 -2.44646768 0.00144650 817.25 -1.36591719e-03 -5.75965307e-01 5.75966927e-01 -1.57316785 0.05836039 817.50 -1.44884001e-01 -1.17684304e+00 1.18572801e+00 -1.69329236 0.16251384 817.75 -1.30097097e+00 -1.93606894e+00 2.33257121e+00 -2.16245819 0.49637934 818.00 -1.86291452e+00 -1.86507095e+00 2.63608424e+00 -2.35561605 0.57356899 818.25 -2.64651864e+00 -9.79696988e-01 2.82203244e+00 -2.78705152 0.46774356 818.50 -3.09273800e+00 -6.49715710e-01 3.16024664e+00 -2.93452591 0.55958873 818.75 -2.89043816e+00 -5.49287244e-01 2.94216744e+00 -2.95379598 0.61195954 819.00 -3.06044075e+00 -4.43156463e-01 3.09235917e+00 -2.99779063 0.65295570 819.25 -3.92908278e+00 -4.35209168e-01 3.95311251e+00 -3.03127625 0.70051761 819.50 -4.41524793e+00 -5.29881569e-01 4.44693027e+00 -3.02215216 0.74932211 819.75 -4.35748724e+00 -8.72154759e-01 4.44391145e+00 -2.94405205 0.83900446 820.00 -4.51533558e+00 -4.94225710e-01 4.54230277e+00 -3.03257172 0.83094929 820.25 -5.08430581e+00 2.37967594e-01 5.08987172e+00 3.09482244 0.87200906 820.50 -5.28373559e+00 7.78414190e-01 5.34076684e+00 2.99532212 0.85319088 820.75 -6.01365446e+00 1.37480763e+00 6.16880345e+00 2.91684071 0.93577547 821.00 -6.32976230e+00 1.48900457e+00 6.50253991e+00 2.91055457 0.93858038 821.25 -6.49849353e+00 1.88238576e+00 6.76563333e+00 2.85964432 0.95509551 821.50 -6.87382252e+00 2.27792055e+00 7.24143343e+00 2.82159153 0.94803529 821.75 -7.62241943e+00 2.97016832e+00 8.18065877e+00 2.77002986 0.94503946 822.00 -8.24337512e+00 4.14534213e+00 9.22697647e+00 2.67565206 0.94767854 822.25 -8.28582210e+00 5.20155493e+00 9.78320099e+00 2.58100699 0.97167555 822.50 -8.21477859e+00 6.21921123e+00 1.03034545e+01 2.49357830 0.95920555 822.75 -7.86522835e+00 7.43033841e+00 1.08199698e+01 2.38461925 0.96976371 823.00 -7.25740794e+00 8.65545993e+00 1.12954396e+01 2.26856280 0.95765106 823.25 -6.48626292e+00 9.64152554e+00 1.16202677e+01 2.16299341 0.97036586 823.50 -5.49383902e+00 1.00486311e+01 1.14523908e+01 2.07112176 0.96816964 823.75 -4.89426393e+00 1.06319481e+01 1.17043641e+01 2.00221200 0.97072121 824.00 -3.71762462e+00 1.15538589e+01 1.21372315e+01 1.88209928 0.96452462 824.25 -3.22999993e+00 1.21345452e+01 1.25570732e+01 1.83094636 0.98200725 824.50 -2.19179102e+00 1.23442936e+01 1.25373654e+01 1.74651999 0.97520587 824.75 -1.23310592e+00 1.22714193e+01 1.23332186e+01 1.67094615 0.97446059 825.00 -2.35482709e-01 1.26860681e+01 1.26882535e+01 1.58935650 0.96847286 825.25 1.01532128e+00 1.30956789e+01 1.31349794e+01 1.49342010 0.97180982 825.50 2.39781571e+00 1.31233266e+01 1.33405855e+01 1.39007580 0.96679798 825.75 3.23340045e+00 1.29426000e+01 1.33403813e+01 1.32598125 0.95656487 826.00 4.58396268e+00 1.26709450e+01 1.34746265e+01 1.22367506 0.95235035 826.25 5.47088891e+00 1.23219401e+01 1.34818705e+01 1.15294675 0.96001748 826.50 6.50771837e+00 1.14712335e+01 1.31886161e+01 1.05476228 0.96737528 826.75 6.99118755e+00 1.11092026e+01 1.31259699e+01 1.00910012 0.96634675 827.00 7.95480479e+00 1.05666752e+01 1.32262445e+01 0.92549284 0.95739174 827.25 8.50155404e+00 1.05370876e+01 1.35390781e+01 0.89190945 0.94576493 827.50 9.11135554e+00 9.47777268e+00 1.31470519e+01 0.80510698 0.93761314 827.75 9.77829614e+00 8.98129684e+00 1.32770015e+01 0.74293880 0.93318646 828.00 1.20346233e+01 7.98497088e+00 1.44427116e+01 0.58580699 0.91131601 828.25 1.23070583e+01 6.76367000e+00 1.40431804e+01 0.50251801 0.90257727 828.50 1.31848605e+01 6.29939480e+00 1.46124235e+01 0.44570993 0.92436548 828.75 1.37703289e+01 5.79047258e+00 1.49382573e+01 0.39805598 0.92372101 829.00 1.54577090e+01 3.54533853e+00 1.58590729e+01 0.22545790 0.91814170 829.25 1.57765113e+01 1.49935541e+00 1.58475984e+01 0.09475261 0.89810804 829.50 1.52793350e+01 -2.35598794e+00 1.54599080e+01 -0.15298951 0.91087441 829.75 1.44343355e+01 -3.65687058e+00 1.48903574e+01 -0.24812466 0.87379204 830.00 1.02779551e+01 -5.96052974e+00 1.18812573e+01 -0.52553398 0.84240583 830.25 9.38156104e+00 -6.16416291e+00 1.12254440e+01 -0.58131594 0.84965293 830.50 7.69090553e+00 -6.23358738e+00 9.89988078e+00 -0.68111918 0.88116452 830.75 7.35507403e+00 -6.29969693e+00 9.68417758e+00 -0.70826153 0.89531993 831.00 6.52905405e+00 -6.44934767e+00 9.17728893e+00 -0.77925678 0.88134007 831.25 4.89961161e+00 -6.04294598e+00 7.77967802e+00 -0.88950552 0.79343693 831.50 3.02750747e+00 -6.02116684e+00 6.73945484e+00 -1.10490264 0.81448453 831.75 2.80060310e+00 -5.76427730e+00 6.40860909e+00 -1.11852860 0.82902754 832.00 2.25344555e+00 -4.91491527e+00 5.40688533e+00 -1.14090357 0.83026280 832.25 1.72448948e+00 -4.21534891e+00 4.55445171e+00 -1.18247180 0.83078998 832.50 1.36882033e+00 -3.88274599e+00 4.11696315e+00 -1.23186117 0.77173914 832.75 1.11001486e+00 -3.54411854e+00 3.71388062e+00 -1.26727465 0.76078708 833.00 1.40449198e+00 -2.96382405e+00 3.27976382e+00 -1.12826357 0.78922888 833.25 1.73368696e+00 -2.73094282e+00 3.23476725e+00 -1.00515880 0.79816977 833.50 1.93144362e+00 -2.62143354e+00 3.25613087e+00 -0.93580396 0.83753547 833.75 2.01524339e+00 -2.49684138e+00 3.20864812e+00 -0.89173073 0.76419657 834.00 2.05000556e+00 -2.50762810e+00 3.23893832e+00 -0.88547069 0.82505215 834.25 2.06878179e+00 -2.61065705e+00 3.33097408e+00 -0.90068388 0.84463589 834.50 2.23861983e+00 -2.81844228e+00 3.59931044e+00 -0.89955565 0.87345176 834.75 1.88540295e+00 -2.92540934e+00 3.48033965e+00 -0.99830290 0.83485335 835.00 1.73298110e+00 -3.02447715e+00 3.48578335e+00 -1.05047743 0.81148103 835.25 9.69500842e-01 -3.18651350e+00 3.33073568e+00 -1.27544384 0.77432559 835.50 9.46356283e-01 -3.31128936e+00 3.44386809e+00 -1.29242028 0.84486733 835.75 9.04113963e-01 -3.35767074e+00 3.47726543e+00 -1.30776669 0.81665324 836.00 5.86161789e-01 -3.15068796e+00 3.20474964e+00 -1.38685677 0.82883909 836.25 4.59665188e-01 -2.97799738e+00 3.01326409e+00 -1.41765114 0.82396321 836.50 3.04111421e-01 -2.92985333e+00 2.94559404e+00 -1.46736921 0.82488641 836.75 -1.05118917e-01 -2.65173022e+00 2.65381294e+00 -1.61041721 0.74995723 837.00 -3.85964248e-01 -2.55108538e+00 2.58011725e+00 -1.72095169 0.69325940 837.25 -5.97828054e-01 -2.12308604e+00 2.20565018e+00 -1.84527370 0.58085714 837.50 -5.59113344e-01 -1.55096282e+00 1.64866413e+00 -1.91678948 0.54091516 837.75 -8.51464554e-01 -1.07938933e+00 1.37479933e+00 -2.23869472 0.54547651 838.00 -7.82368689e-01 -9.53542985e-01 1.23342815e+00 -2.25790452 0.44660998 838.25 -2.49058435e-01 -1.72226677e-01 3.02807087e-01 -2.53658668 0.04356609 838.50 1.81269207e-02 2.63245695e-01 2.63869060e-01 1.50204553 0.04137891 838.75 6.20806190e-01 4.62072970e-01 7.73893892e-01 0.63985029 0.26949602 839.00 8.80336902e-01 3.28467698e-01 9.39619120e-01 0.35711784 0.31246683 839.25 1.80898248e+00 -9.05036178e-03 1.80900512e+00 -0.00500297 0.61614416 839.50 1.93107428e+00 -1.18488523e-01 1.93470603e+00 -0.06128203 0.67300036 839.75 2.16087210e+00 -6.93218257e-01 2.26934347e+00 -0.31043287 0.63265747 840.00 2.38971380e+00 -1.01272596e+00 2.59544715e+00 -0.40084147 0.72605250 840.25 2.26784405e+00 -1.40171279e+00 2.66606740e+00 -0.55360884 0.74488837 840.50 2.33757341e+00 -1.60247360e+00 2.83410852e+00 -0.60094749 0.76365032 840.75 2.74202463e+00 -2.13458703e+00 3.47493322e+00 -0.66147504 0.84819208 841.00 3.14971030e+00 -2.47057206e+00 4.00304900e+00 -0.66514417 0.79811720 841.25 3.18326559e+00 -2.52392702e+00 4.06243615e+00 -0.67038040 0.73968837 841.50 3.36385866e+00 -3.39965155e+00 4.78259090e+00 -0.79069017 0.77775207 841.75 3.30495489e+00 -4.88247651e+00 5.89587175e+00 -0.97574161 0.87551749 842.00 3.09564908e+00 -5.72066679e+00 6.50454240e+00 -1.07478526 0.90676728 842.25 2.42533368e+00 -6.33978935e+00 6.78786951e+00 -1.20541646 0.89938607 842.50 1.37844381e+00 -6.70456485e+00 6.84480074e+00 -1.36802410 0.88091715 842.75 1.87531517e-01 -7.88233533e+00 7.88456583e+00 -1.54700945 0.93096778 843.00 -3.14724265e-01 -8.25388044e+00 8.25987855e+00 -1.60890832 0.89178896 843.25 -1.64006127e+00 -8.53476781e+00 8.69091839e+00 -1.76064448 0.88030310 843.50 -3.44433486e+00 -8.82538735e+00 9.47369539e+00 -1.94289174 0.90464427 843.75 -4.80284064e+00 -8.52163006e+00 9.78189435e+00 -2.08402545 0.93562284 844.00 -5.92652753e+00 -7.63764708e+00 9.66733580e+00 -2.23070743 0.91567497 844.25 -7.43051240e+00 -6.92739513e+00 1.01588049e+01 -2.39122129 0.93458540 844.50 -8.60565688e+00 -5.66160853e+00 1.03010262e+01 -2.55968817 0.88881880 844.75 -9.89221940e+00 -4.50034811e+00 1.08678028e+01 -2.71463975 0.90516323 845.00 -1.04963415e+01 -2.88829761e+00 1.08864801e+01 -2.87306669 0.90128961 845.25 -1.06760099e+01 -1.81679792e+00 1.08294941e+01 -2.97303169 0.92984065 845.50 -1.11543730e+01 -4.44092396e-01 1.11632099e+01 -3.10180037 0.89644537 845.75 -1.11015440e+01 3.08785987e-01 1.11058376e+01 3.11378513 0.90049973 846.00 -1.12520158e+01 2.32663067e+00 1.14900422e+01 2.93769166 0.86621599 846.25 -1.08816971e+01 4.23738004e+00 1.16776163e+01 2.77025371 0.87779157 846.50 -9.14638235e+00 5.71391302e+00 1.07844848e+01 2.58319589 0.86792015 846.75 -8.66339697e+00 6.67925383e+00 1.09392358e+01 2.48480276 0.87499663 847.00 -7.17530060e+00 7.92065232e+00 1.06874539e+01 2.30686028 0.79146638 847.25 -6.03081580e+00 8.25336083e+00 1.02219716e+01 2.20183730 0.77170348 847.50 -5.55483658e+00 8.14849669e+00 9.86175481e+00 2.16913507 0.78295596 847.75 -4.22957923e+00 8.84612047e+00 9.80526328e+00 2.01679386 0.75367093 848.00 -3.45109578e+00 8.69380822e+00 9.35373527e+00 1.94867944 0.72320510 848.25 -2.95231746e+00 7.93175750e+00 8.46338912e+00 1.92712294 0.68927358 848.50 -7.56473881e-01 8.27680707e+00 8.31130483e+00 1.66193993 0.69224186 848.75 4.51200222e-01 8.37083214e+00 8.38298350e+00 1.51694696 0.73534874 849.00 1.27043320e+00 7.64099934e+00 7.74589385e+00 1.40603817 0.71582157 849.25 1.27745658e+00 7.11807223e+00 7.23179421e+00 1.39322005 0.68555721 849.50 2.14941952e+00 6.05938936e+00 6.42932373e+00 1.22991798 0.65749473 849.75 1.51719257e+00 5.28400917e+00 5.49751091e+00 1.29118916 0.62314631 850.00 1.69865914e-01 4.73626225e+00 4.73930739e+00 1.53494672 0.64466510 850.25 4.80101853e-01 4.74080391e+00 4.76505189e+00 1.46987027 0.63025364 850.50 6.56874580e-01 5.46159575e+00 5.50095558e+00 1.45109972 0.76673705 850.75 5.53536172e-01 5.81050057e+00 5.83680728e+00 1.47581816 0.75233467 851.00 1.81185837e+00 5.44535030e+00 5.73887364e+00 1.24958441 0.73335319 851.25 2.20629462e+00 5.54745330e+00 5.97008995e+00 1.19226300 0.80187555 851.50 2.19805288e+00 6.03667783e+00 6.42440003e+00 1.22160149 0.84342560 851.75 2.12465487e+00 5.80911922e+00 6.18546881e+00 1.22016443 0.84062356 852.00 2.15637389e+00 5.47157122e+00 5.88115975e+00 1.19538210 0.88326273 852.25 2.28233842e+00 5.65280700e+00 6.09617057e+00 1.18705870 0.88357562 852.50 2.37338163e+00 5.69773772e+00 6.17228932e+00 1.17610627 0.92653234 852.75 2.51352911e+00 5.75133320e+00 6.27659638e+00 1.15877695 0.90470105 853.00 2.76760523e+00 5.86379867e+00 6.48411702e+00 1.12981359 0.88140659 853.25 3.49441197e+00 6.19535883e+00 7.11290279e+00 1.05724002 0.88430319 853.50 3.92272411e+00 6.49933448e+00 7.59138414e+00 1.02776489 0.87689510 853.75 4.52373485e+00 6.88985629e+00 8.24222644e+00 0.98981005 0.89315261 854.00 5.26362760e+00 6.68137307e+00 8.50567585e+00 0.90353494 0.91337894 854.25 6.23839055e+00 6.28945751e+00 8.85859991e+00 0.78947442 0.88890302 854.50 6.97609340e+00 5.52433756e+00 8.89854958e+00 0.66977965 0.91686652 854.75 7.30381485e+00 4.30613998e+00 8.47871175e+00 0.53271812 0.91212638 855.00 7.33633463e+00 3.52638604e+00 8.13985284e+00 0.44806770 0.91535567 855.25 7.43456563e+00 2.83633986e+00 7.95723506e+00 0.36446332 0.93065651 855.50 7.27681387e+00 2.50746699e+00 7.69671429e+00 0.33184093 0.93439481 855.75 7.47069184e+00 2.03919880e+00 7.74400209e+00 0.26646850 0.93497493 856.00 7.55639654e+00 1.40119606e+00 7.68521171e+00 0.18334922 0.94740230 856.25 7.44780086e+00 9.36985769e-01 7.50650917e+00 0.12514954 0.93524763 856.50 7.40364854e+00 6.01054499e-01 7.42800634e+00 0.08100590 0.93058486 856.75 7.16361934e+00 -2.53816935e-01 7.16811448e+00 -0.03541657 0.93114128 857.00 7.08714231e+00 -7.42784911e-01 7.12596067e+00 -0.10442615 0.94237247 857.25 6.95252297e+00 -9.43797119e-01 7.01629024e+00 -0.13492412 0.93067468 857.50 6.86968597e+00 -1.43115242e+00 7.01717768e+00 -0.20539090 0.92884573 857.75 6.58175485e+00 -2.50230858e+00 7.04138091e+00 -0.36331186 0.90503106 858.00 5.96751161e+00 -3.18057425e+00 6.76219250e+00 -0.48968349 0.90822122 858.25 5.25365259e+00 -3.32981833e+00 6.22001251e+00 -0.56490963 0.91240785 858.50 4.82128802e+00 -3.35346701e+00 5.87286635e+00 -0.60773595 0.92192880 858.75 4.00101397e+00 -3.06429346e+00 5.03964356e+00 -0.65358659 0.93370341 859.00 3.78636104e+00 -2.80862060e+00 4.71432706e+00 -0.63821504 0.93254895 859.25 3.37642906e+00 -2.31463242e+00 4.09362876e+00 -0.60094618 0.91511970 859.50 3.42012771e+00 -2.23720162e+00 4.08685021e+00 -0.57927175 0.93674655 859.75 3.63877443e+00 -2.14568959e+00 4.22429440e+00 -0.53279203 0.94274727 860.00 3.78298959e+00 -2.23686276e+00 4.39483392e+00 -0.53399416 0.95227027 860.25 3.60323410e+00 -2.44347160e+00 4.35360189e+00 -0.59589881 0.94529344 860.50 3.41976494e+00 -2.51819090e+00 4.24689035e+00 -0.63471663 0.93480839 860.75 3.12485605e+00 -2.82771857e+00 4.21434665e+00 -0.73552209 0.96149208 861.00 2.98445775e+00 -2.79371469e+00 4.08801050e+00 -0.75239918 0.95971661 861.25 2.88318297e+00 -2.43762600e+00 3.77554825e+00 -0.70185450 0.94391547 861.50 2.94050296e+00 -2.30707578e+00 3.73753346e+00 -0.66527089 0.93474532 861.75 3.02662351e+00 -2.13278258e+00 3.70259522e+00 -0.61385593 0.93244535 862.00 3.15525838e+00 -2.09592122e+00 3.78794684e+00 -0.58633664 0.91767845 862.25 3.43262576e+00 -2.07569371e+00 4.01141172e+00 -0.54386500 0.92548361 862.50 3.37737552e+00 -2.28287313e+00 4.07653961e+00 -0.59438904 0.90714705 862.75 3.38167907e+00 -2.87369787e+00 4.43778017e+00 -0.70436884 0.94500235 863.00 3.27891671e+00 -3.11188386e+00 4.52052165e+00 -0.75926766 0.94674161 863.25 3.06932133e+00 -3.16424250e+00 4.40830625e+00 -0.80062442 0.94394470 863.50 3.00332384e+00 -3.22087261e+00 4.40385904e+00 -0.82033605 0.93217707 863.75 2.77490716e+00 -3.56296480e+00 4.51606332e+00 -0.90910429 0.93391696 864.00 2.58165986e+00 -3.62534231e+00 4.45062630e+00 -0.95198582 0.94970203 864.25 2.44428142e+00 -3.68868072e+00 4.42502849e+00 -0.98558396 0.95638970 864.50 2.36827127e+00 -3.63273611e+00 4.33652862e+00 -0.99306909 0.92928701 864.75 2.32915262e+00 -3.60439739e+00 4.29146041e+00 -0.99709885 0.93026155 865.00 2.25751420e+00 -3.62584174e+00 4.27119406e+00 -1.01391177 0.93051278 865.25 2.05324495e+00 -3.87579513e+00 4.38606916e+00 -1.08362438 0.93701432 865.50 1.71932963e+00 -3.82227926e+00 4.19117086e+00 -1.14809384 0.94866833 865.75 1.63559597e+00 -3.79707403e+00 4.13436154e+00 -1.16406407 0.95672014 866.00 1.47689737e+00 -3.95727012e+00 4.22388597e+00 -1.21359488 0.93954594 866.25 1.47449827e+00 -4.10786525e+00 4.36448188e+00 -1.22617489 0.92851273 866.50 1.27288491e+00 -4.26454943e+00 4.45046265e+00 -1.28073414 0.91843536 866.75 1.04436423e+00 -4.27789515e+00 4.40353081e+00 -1.33134958 0.91791837 867.00 7.35005702e-01 -4.46941288e+00 4.52944642e+00 -1.40780284 0.91792491 867.25 5.63481821e-01 -4.51621967e+00 4.55123630e+00 -1.44666931 0.91311837 867.50 1.99189314e-01 -4.34136060e+00 4.34592778e+00 -1.52494671 0.90382545 867.75 1.17373445e-01 -4.22074222e+00 4.22237391e+00 -1.54299477 0.90475765 868.00 -1.99127858e-01 -4.17420080e+00 4.17894774e+00 -1.61846462 0.90991130 868.25 -2.27124892e-01 -4.12941400e+00 4.13565542e+00 -1.62574269 0.93703161 868.50 -5.48852439e-01 -3.87940949e+00 3.91804250e+00 -1.71134190 0.90065589 868.75 -6.53446616e-01 -3.75259496e+00 3.80906306e+00 -1.74319960 0.86899517 869.00 -9.33108200e-01 -3.52781025e+00 3.64912813e+00 -1.82937544 0.79830403 869.25 -8.20326734e-01 -3.39886387e+00 3.49645700e+00 -1.80762043 0.76769798 869.50 -6.12637418e-01 -3.66485743e+00 3.71571050e+00 -1.73643024 0.76203330 869.75 -6.61181696e-01 -3.65311836e+00 3.71247020e+00 -1.74984904 0.69672517 870.00 -3.43923204e-01 -3.83132014e+00 3.84672552e+00 -1.66032261 0.59684218 870.25 -2.56101207e-01 -3.78431710e+00 3.79297295e+00 -1.63836765 0.52649610 870.50 -7.33850801e-01 -3.09348325e+00 3.17933572e+00 -1.80371556 0.40700556 870.75 -3.26087665e-01 -3.06792599e+00 3.08520713e+00 -1.67668804 0.39131341 871.00 -2.10505016e-01 -3.87436199e+00 3.88007644e+00 -1.62507578 0.57626769 871.25 -7.64849652e-01 -4.13345652e+00 4.20362436e+00 -1.75376557 0.65368247 871.50 -1.04875446e+00 -3.53792369e+00 3.69009349e+00 -1.85897669 0.67775875 871.75 -1.03770759e+00 -3.08543125e+00 3.25526082e+00 -1.89523694 0.65450611 872.00 -1.01398638e+00 -3.21629683e+00 3.37234839e+00 -1.87619837 0.75633975 872.25 -1.07532222e+00 -3.27594590e+00 3.44791813e+00 -1.88796299 0.76284413 872.50 -1.29987662e+00 -3.15075253e+00 3.40836042e+00 -1.96208376 0.83301376 872.75 -1.30035782e+00 -3.23403743e+00 3.48567476e+00 -1.95309879 0.86233718 873.00 -1.29496800e+00 -3.25767108e+00 3.50561878e+00 -1.94915727 0.83260098 873.25 -1.23773749e+00 -3.34460428e+00 3.56628264e+00 -1.92523776 0.75261470 873.50 -1.54564980e+00 -3.68890121e+00 3.99962816e+00 -1.96757401 0.72689793 873.75 -1.47319553e+00 -3.52654486e+00 3.82188746e+00 -1.96650568 0.61515255 874.00 -1.76469533e+00 -3.40746415e+00 3.83731176e+00 -2.04865415 0.64672979 874.25 -2.30723821e+00 -3.50532153e+00 4.19650178e+00 -2.15292155 0.72303511 874.50 -2.16798510e+00 -3.54037015e+00 4.15143111e+00 -2.12025536 0.77969145 874.75 -2.24430654e+00 -3.35809108e+00 4.03902061e+00 -2.15994825 0.70966027 875.00 -2.13067315e+00 -3.16321280e+00 3.81388034e+00 -2.16356901 0.72638279 875.25 -1.90874747e+00 -3.03434634e+00 3.58476981e+00 -2.13230079 0.77059369 875.50 -1.55141161e+00 -3.16295181e+00 3.52294509e+00 -2.02681095 0.82848527 875.75 -1.17895596e+00 -2.88159844e+00 3.11344612e+00 -1.95915079 0.71562975 876.00 -7.43812479e-01 -2.95672803e+00 3.04885186e+00 -1.81724840 0.70110229 876.25 -9.93371093e-01 -3.30392642e+00 3.45003130e+00 -1.86286201 0.72605548 876.50 -9.16422583e-01 -3.79265156e+00 3.90179910e+00 -1.80788300 0.72359097 876.75 -1.57091074e-01 -4.53550676e+00 4.53822644e+00 -1.60541832 0.71008145 877.00 4.78460549e-01 -5.32415057e+00 5.34560602e+00 -1.48117100 0.74788008 877.25 7.02632347e-01 -5.54443889e+00 5.58878295e+00 -1.44474087 0.63750431 877.50 1.78220126e-01 -5.43027537e+00 5.43319915e+00 -1.53798838 0.54690018 877.75 6.06414891e-01 -6.38553096e+00 6.41426103e+00 -1.47611326 0.50316636 878.00 5.63380565e-01 -7.03796067e+00 7.06047364e+00 -1.49091782 0.53649398 878.25 2.60876791e-01 -8.55287603e+00 8.55685369e+00 -1.54030414 0.43250810 878.50 7.08603598e-01 -9.42722240e+00 9.45381623e+00 -1.49577173 0.36238189 878.75 1.68905135e+00 -6.33683585e+00 6.55807770e+00 -1.31030761 0.23239651 879.00 1.85883820e+00 -4.53175165e+00 4.89816827e+00 -1.18154420 0.13977412 879.25 1.59807730e+00 -3.37602828e+00 3.73515970e+00 -1.12868680 0.08371193 879.50 2.97930987e+00 -2.67197637e+00 4.00196765e+00 -0.73106875 0.10049634 879.75 6.62579276e+00 9.48122286e-01 6.69328511e+00 0.14213081 0.30563303 880.00 6.66147691e+00 1.39586810e+00 6.80615327e+00 0.20655478 0.37856405 880.25 4.84841436e+00 2.03167322e+00 5.25688290e+00 0.39681055 0.50772499 880.50 4.30324023e+00 2.51539183e+00 4.98448318e+00 0.52897009 0.58806582 880.75 3.30681375e+00 3.01526861e+00 4.47513820e+00 0.73931545 0.57712911 881.00 2.14130950e+00 3.19868478e+00 3.84925846e+00 0.98088007 0.49862935 881.25 5.74796196e-01 3.13172467e+00 3.18403676e+00 1.38927678 0.47916624 881.50 6.10107872e-02 3.19423905e+00 3.19482166e+00 1.55169839 0.49075059 881.75 -3.25839000e-01 3.75188222e+00 3.76600468e+00 1.65742578 0.44808828 882.00 -7.59300193e-01 4.11034182e+00 4.17988597e+00 1.75346625 0.51302486 882.25 -1.21393351e+00 4.16219724e+00 4.33561073e+00 1.85458143 0.60074590 882.50 -1.53812795e+00 3.87141440e+00 4.16577569e+00 1.94897630 0.54528668 882.75 -1.88255527e+00 2.83785061e+00 3.40549709e+00 2.15651567 0.32328542 883.00 -1.82689984e+00 2.59795157e+00 3.17599045e+00 2.18367194 0.27439101 883.25 -1.58891452e+00 3.04820168e+00 3.43746751e+00 2.05130922 0.34144845 883.50 -1.16384001e+00 3.00464000e+00 3.22217087e+00 1.94034808 0.28185118 883.75 -2.16169620e+00 2.68750780e+00 3.44900401e+00 2.24818393 0.23210836 884.00 -9.20595757e-01 3.49996631e+00 3.61901378e+00 1.82800032 0.21360413 884.25 6.26720875e-01 2.66693205e+00 2.73958128e+00 1.33998726 0.15421673 884.50 1.11777202e+00 6.04946291e-01 1.27097376e+00 0.49606747 0.04553214 884.75 1.12811735e+00 1.18726296e+00 1.63775519e+00 0.81093727 0.07658353 885.00 1.25688634e+00 1.32775836e+00 1.82830675e+00 0.81281170 0.08401063 885.25 1.09942014e+00 1.49316226e+00 1.85425408e+00 0.93611896 0.09953722 885.50 1.06027215e+00 2.17314120e+00 2.41799911e+00 1.11687677 0.22009088 885.75 1.02049102e+00 3.26116372e+00 3.41710268e+00 1.26752673 0.43990092 886.00 1.73843403e+00 2.95925050e+00 3.43210088e+00 1.03965027 0.44141452 886.25 1.50117837e+00 3.09116052e+00 3.43639490e+00 1.11870593 0.46655063 886.50 -5.96831229e-03 2.46105280e+00 2.46106003e+00 1.57322143 0.39400090 886.75 -9.97662407e-01 2.36329539e+00 2.56524762e+00 1.97024954 0.40112093 887.00 -2.06445166e+00 2.56960963e+00 3.29618784e+00 2.24761346 0.41854802 887.25 -3.32803501e+00 2.71822385e+00 4.29704060e+00 2.45671218 0.49109439 887.50 -3.41147849e+00 3.97642065e+00 5.23928494e+00 2.27987444 0.58680358 887.75 -2.89879688e+00 4.54311920e+00 5.38915164e+00 2.13873426 0.63853226 888.00 -2.84937040e+00 3.77914237e+00 4.73295138e+00 2.21683516 0.65047078 888.25 -3.10990694e+00 2.96579270e+00 4.29737682e+00 2.37990982 0.61781889 888.50 -4.09535669e+00 1.52667509e+00 4.37066165e+00 2.78476798 0.68787190 888.75 -4.16106283e+00 1.09441638e+00 4.30257959e+00 2.88440383 0.73677384 889.00 -4.68731195e+00 -4.91817392e-01 4.71304335e+00 -3.03704993 0.72683691 889.25 -4.59461209e+00 -1.08665031e+00 4.72136306e+00 -2.90935461 0.75422071 889.50 -3.60779421e+00 -2.50083119e+00 4.38979905e+00 -2.53546222 0.70337008 889.75 -3.40762141e+00 -3.10565513e+00 4.61052898e+00 -2.40252297 0.79923320 890.00 -2.70678589e+00 -3.51847380e+00 4.43918323e+00 -2.22653973 0.78382623 890.25 -2.26156438e+00 -3.76246167e+00 4.38985094e+00 -2.11201424 0.75932552 890.50 -1.12730510e+00 -2.80884785e+00 3.02662238e+00 -1.95245799 0.52420140 890.75 -5.92159017e-01 -2.47039357e+00 2.54037334e+00 -1.80605980 0.47134968 891.00 1.45836048e-01 -2.61078680e+00 2.61485676e+00 -1.51499527 0.43001220 891.25 6.99223294e-01 -2.43065740e+00 2.52923084e+00 -1.29069098 0.40115623 891.50 9.87139586e-01 -2.41227416e+00 2.60643649e+00 -1.18237102 0.44540341 891.75 1.19522284e+00 -2.42986641e+00 2.70791588e+00 -1.11365912 0.55545562 892.00 1.03173297e+00 -2.55487125e+00 2.75532938e+00 -1.18699282 0.58384924 892.25 6.76933645e-01 -2.17668541e+00 2.27951717e+00 -1.26928509 0.42830291 892.50 1.64778033e-01 -1.23021715e+00 1.24120346e+00 -1.43764658 0.20944274 892.75 1.04575123e-01 -9.55644152e-01 9.61348897e-01 -1.46180107 0.13435693 893.00 -5.52938904e-01 -7.83836604e-02 5.58467036e-01 -3.00077266 0.03948020 893.25 -1.25531179e+00 6.50745209e-02 1.25699736e+00 3.08979969 0.14485339 893.50 -1.34954754e+00 2.53568398e-01 1.37316259e+00 2.95586661 0.15264273 893.75 -1.46046666e+00 6.41074488e-01 1.59497316e+00 2.72796429 0.18643797 894.00 -1.81837867e+00 9.89647419e-01 2.07024226e+00 2.64317694 0.26181702 894.25 -2.17347431e+00 7.56680260e-01 2.30142469e+00 2.80657297 0.26219342 894.50 -1.97171950e+00 7.20752777e-01 2.09932426e+00 2.79113670 0.19688314 894.75 -2.37863892e+00 9.81964123e-01 2.57335902e+00 2.75007846 0.27630791 895.00 -2.67656236e+00 1.09820490e+00 2.89310215e+00 2.75223499 0.30073496 895.25 -1.95734157e+00 9.54735765e-01 2.17777557e+00 2.68777548 0.17590879 895.50 -2.60114397e+00 9.82862710e-01 2.78064184e+00 2.78031881 0.23777505 895.75 -4.10221160e+00 2.51842947e+00 4.81358775e+00 2.59100073 0.47967558 896.00 -4.54802763e+00 3.14675669e+00 5.53051833e+00 2.53632716 0.64156357 896.25 -3.89506400e+00 3.10556485e+00 4.98157170e+00 2.46849546 0.57459150 896.50 -3.87103197e+00 2.59996890e+00 4.66312415e+00 2.55014971 0.61161525 896.75 -3.17083411e+00 1.67013980e+00 3.58379071e+00 2.65679873 0.41739018 897.00 -3.12268200e+00 1.08082444e+00 3.30444010e+00 2.80837808 0.35874984 897.25 -3.78509235e+00 1.52384236e+00 4.08032102e+00 2.75885505 0.46640694 897.50 -3.50253263e+00 1.62221547e+00 3.85996345e+00 2.70785305 0.37205397 897.75 -2.52195951e+00 1.15383268e+00 2.77337513e+00 2.71250739 0.23156340 898.00 -2.49876518e+00 1.16378958e+00 2.75648936e+00 2.70572188 0.27961242 898.25 -2.30299570e+00 5.83908751e-01 2.37586586e+00 2.89328206 0.18326919 898.50 -1.87450339e+00 -1.91038577e-01 1.88421302e+00 -3.04002908 0.10852018 898.75 -1.95223470e+00 -4.41580923e-01 2.00155291e+00 -2.91914343 0.11963981 899.00 -2.39598038e+00 1.15409058e-01 2.39875827e+00 3.09346207 0.19105018 899.25 -1.52815269e+00 1.79438459e-02 1.52825804e+00 3.12985101 0.07374433 899.50 -1.89620108e+00 -1.26612325e-01 1.90042343e+00 -3.07492005 0.11805634 899.75 -1.82651761e+00 -8.61188015e-01 2.01935915e+00 -2.70101061 0.13017009 900.00 -4.70890056e-01 -1.05207192e+00 1.15264599e+00 -1.99163889 0.04289949 900.25 1.84391198e-01 -3.92058593e-01 4.33255183e-01 -1.13117713 0.00661403 900.50 1.97948471e-02 -4.41929587e-01 4.42372689e-01 -1.52603439 0.00676586 900.75 5.55451092e-01 -1.28966463e+00 1.40419399e+00 -1.16411253 0.05334855 901.00 -3.39464390e-01 -1.12898692e+00 1.17891796e+00 -1.86287735 0.03309768 901.25 1.13395273e-02 -7.67687665e-01 7.67771409e-01 -1.55602638 0.01839424 901.50 3.84176283e-01 -6.66259181e-01 7.69085634e-01 -1.04774778 0.02700701 901.75 6.35210050e-01 -1.12523267e+00 1.29214564e+00 -1.05687795 0.06132531 902.00 8.77225136e-01 -1.89086387e+00 2.08444000e+00 -1.13642024 0.15505711 902.25 2.04934909e+00 -2.47854246e+00 3.21605417e+00 -0.87990458 0.30790177 902.50 2.31843413e+00 -2.58162470e+00 3.46985921e+00 -0.83905832 0.32883230 902.75 2.55673922e+00 -3.39885958e+00 4.25313554e+00 -0.92586671 0.45257773 903.00 2.86916890e+00 -3.88687782e+00 4.83114369e+00 -0.93491079 0.50235423 903.25 2.65256712e+00 -4.87155998e+00 5.54690985e+00 -1.07218514 0.70596467 903.50 2.39245193e+00 -5.25018094e+00 5.76959497e+00 -1.14322116 0.79713458 903.75 2.88164901e+00 -5.43597023e+00 6.15253390e+00 -1.08335377 0.79006551 904.00 3.25017597e+00 -5.03854749e+00 5.99588231e+00 -0.99790023 0.78373415 904.25 3.25697150e+00 -4.84197984e+00 5.83546331e+00 -0.97866089 0.81376410 904.50 3.15752963e+00 -5.30843217e+00 6.17652374e+00 -1.03419881 0.87031027 904.75 3.07913179e+00 -6.24944937e+00 6.96682639e+00 -1.11300214 0.87535243 905.00 3.12162070e+00 -6.35508108e+00 7.08036520e+00 -1.11421285 0.83464272 905.25 2.41077695e+00 -7.43122877e+00 7.81249042e+00 -1.25709669 0.87217751 905.50 1.42701797e+00 -7.99456627e+00 8.12092791e+00 -1.39415816 0.90520432 905.75 8.53870821e-01 -7.91299889e+00 7.95893503e+00 -1.46330489 0.91973814 906.00 5.11562604e-01 -7.55063359e+00 7.56794317e+00 -1.50314875 0.90134448 906.25 -2.08462720e-01 -7.40502647e+00 7.40796016e+00 -1.59894041 0.89789593 906.50 -9.80069238e-01 -6.81771376e+00 6.88779766e+00 -1.71357156 0.88116218 906.75 -1.22307901e+00 -6.74969899e+00 6.85961797e+00 -1.75005617 0.89601918 907.00 -1.85198087e+00 -6.21930002e+00 6.48918530e+00 -1.86021484 0.83785554 907.25 -2.16823554e+00 -6.11632824e+00 6.48927704e+00 -1.91147401 0.82776244 907.50 -2.61547371e+00 -4.77099032e+00 5.44086862e+00 -2.07225924 0.82431708 907.75 -2.70415304e+00 -4.15605632e+00 4.95835132e+00 -2.14763089 0.85293449 908.00 -2.46866593e+00 -3.47144177e+00 4.25972059e+00 -2.18895684 0.82150526 908.25 -2.33585458e+00 -3.13109552e+00 3.90640190e+00 -2.21174428 0.81449501 908.50 -1.93074739e+00 -2.91158649e+00 3.49358289e+00 -2.15634338 0.78027250 908.75 -1.49000635e+00 -2.88196683e+00 3.24435690e+00 -2.04795934 0.77717072 909.00 -8.00869515e-01 -2.79148046e+00 2.90409282e+00 -1.85018981 0.77236704 909.25 -6.91156104e-01 -2.85027641e+00 2.93287784e+00 -1.80869190 0.85673178 909.50 -5.01995047e-01 -2.88699525e+00 2.93031408e+00 -1.74295652 0.86438845 909.75 -3.73997361e-01 -2.89127784e+00 2.91536645e+00 -1.69943568 0.87087366 910.00 -5.52841320e-01 -2.98497039e+00 3.03573414e+00 -1.75392950 0.88256368 910.25 -4.97414357e-01 -2.93162482e+00 2.97352402e+00 -1.73886758 0.88166334 910.50 -2.35249053e-01 -3.02199870e+00 3.03114141e+00 -1.64848517 0.82661188 910.75 -2.75401550e-01 -3.16201155e+00 3.17398220e+00 -1.65767403 0.79714017 911.00 -1.97003786e-01 -3.20198528e+00 3.20803994e+00 -1.63224438 0.82753174 911.25 -1.47439699e-01 -3.22945329e+00 3.23281719e+00 -1.61641934 0.82985442 911.50 2.61846788e-01 -3.31541272e+00 3.32573679e+00 -1.49198129 0.74367345 911.75 4.71886909e-01 -3.52439777e+00 3.55584826e+00 -1.43769642 0.74094132 912.00 5.37644571e-01 -4.19477188e+00 4.22908652e+00 -1.44332117 0.79662633 912.25 6.40283754e-01 -4.52865424e+00 4.57369353e+00 -1.43034227 0.77849944 912.50 8.44571661e-02 -4.67225116e+00 4.67301444e+00 -1.55272196 0.68146064 912.75 -3.88514858e-01 -4.88319843e+00 4.89862947e+00 -1.65019064 0.69879236 913.00 -1.07040992e+00 -5.17852724e+00 5.28799790e+00 -1.77462736 0.56606661 913.25 -2.13176459e+00 -4.31196470e+00 4.81014135e+00 -2.02994072 0.44870987 913.50 -4.46854762e+00 -3.23179067e+00 5.51474286e+00 -2.51544518 0.52162185 913.75 -4.61469571e+00 -2.07902188e+00 5.06139788e+00 -2.71830473 0.47488944 914.00 -4.58793825e+00 -2.87585898e-01 4.59694279e+00 -3.07899152 0.50712912 914.25 -3.83879065e+00 4.02605258e-01 3.85984516e+00 3.03709652 0.48349304 914.50 -3.59567692e+00 1.46494751e+00 3.88264905e+00 2.75470690 0.71095470 914.75 -2.99210081e+00 1.60100895e+00 3.39350805e+00 2.65027758 0.69219360 915.00 -2.15156923e+00 1.27463552e+00 2.50078904e+00 2.60676434 0.64307763 915.25 -1.82654979e+00 1.22540225e+00 2.19952150e+00 2.55067633 0.61890647 915.50 -1.48623068e+00 1.08615078e+00 1.84081643e+00 2.51048733 0.64081395 915.75 -1.12509186e+00 1.26210979e+00 1.69078468e+00 2.29886051 0.55999879 916.00 -6.51741974e-01 1.23060749e+00 1.39253811e+00 2.05785035 0.51457813 916.25 -2.23663887e-01 1.31460348e+00 1.33349460e+00 1.73932052 0.46400777 916.50 3.74061556e-01 1.26929336e+00 1.32326402e+00 1.28420840 0.51151539 916.75 8.04665825e-01 1.08548908e+00 1.35121191e+00 0.93289081 0.40472261 917.00 1.39001534e+00 7.46873005e-01 1.57796132e+00 0.49305039 0.51760957 917.25 1.62150578e+00 4.14812155e-01 1.67372343e+00 0.25044792 0.50378722 917.50 1.78768320e+00 -3.60797390e-02 1.78804725e+00 -0.02017966 0.52671673 917.75 1.81979935e+00 -4.27455191e-01 1.86932812e+00 -0.23070903 0.50327063 918.00 1.79158556e+00 -7.34347445e-01 1.93624508e+00 -0.38900040 0.48198624 918.25 2.05261236e+00 -1.47643527e+00 2.52845380e+00 -0.62355906 0.65100662 918.50 2.10688133e+00 -1.72989914e+00 2.72607776e+00 -0.68745770 0.71451825 918.75 1.57342962e+00 -1.98537903e+00 2.53326088e+00 -0.90064014 0.60973609 919.00 1.28934882e+00 -2.32146352e+00 2.65548738e+00 -1.06381407 0.67440334 919.25 1.09701403e+00 -2.66820142e+00 2.88491571e+00 -1.18072043 0.76543333 919.50 9.93010299e-01 -2.62434356e+00 2.80593097e+00 -1.20906194 0.70408352 919.75 6.82699028e-01 -2.74801164e+00 2.83154480e+00 -1.32729226 0.66706354 920.00 4.61766847e-01 -2.73587653e+00 2.77457186e+00 -1.40359015 0.70623764 920.25 3.70451321e-01 -2.45862004e+00 2.48637220e+00 -1.42124680 0.73510726 920.50 3.19056512e-01 -2.42471900e+00 2.44562043e+00 -1.43996304 0.75093868 920.75 2.49630928e-01 -2.40541705e+00 2.41833554e+00 -1.46738786 0.65959160 921.00 3.57985838e-01 -2.66223468e+00 2.68619570e+00 -1.43712994 0.68953440 921.25 -8.37589308e-02 -2.73936369e+00 2.74064390e+00 -1.60136286 0.76537292 921.50 -1.34511567e-01 -2.49828945e+00 2.50190798e+00 -1.62458586 0.76190218 921.75 1.64275518e-01 -2.40543120e+00 2.41103416e+00 -1.50260862 0.71251450 922.00 2.41130581e-01 -2.46896929e+00 2.48071629e+00 -1.47344061 0.74496361 922.25 -9.20833704e-02 -3.02558970e+00 3.02699065e+00 -1.60122179 0.79702415 922.50 -2.30307116e-01 -3.06559386e+00 3.07423276e+00 -1.64578189 0.82046317 922.75 -3.96253663e-01 -2.91180047e+00 2.93863896e+00 -1.70605092 0.83103104 923.00 -6.01687502e-01 -2.86944607e+00 2.93185071e+00 -1.77748938 0.81845831 923.25 -5.46661791e-01 -2.70741440e+00 2.76205210e+00 -1.77003050 0.72438281 923.50 -7.12706327e-01 -2.61477854e+00 2.71016921e+00 -1.83690061 0.71726570 923.75 -9.11192344e-01 -2.49934370e+00 2.66026135e+00 -1.92039402 0.79593825 924.00 -1.05426516e+00 -2.45879785e+00 2.67528726e+00 -1.97585806 0.82316538 924.25 -1.06962442e+00 -2.53876206e+00 2.75488823e+00 -1.96954358 0.78809711 924.50 -1.11423704e+00 -2.67940685e+00 2.90185204e+00 -1.96489320 0.76230513 924.75 -1.02817153e+00 -2.59357507e+00 2.78994056e+00 -1.94822152 0.74488697 925.00 -1.08213020e+00 -2.65165439e+00 2.86396173e+00 -1.95826268 0.75839278 925.25 -1.04613707e+00 -2.56542518e+00 2.77052507e+00 -1.95799423 0.77769665 925.50 -1.08290998e+00 -2.44865290e+00 2.67742321e+00 -1.98718438 0.78592126 925.75 -8.49488363e-01 -2.51914276e+00 2.65851664e+00 -1.89603475 0.79101759 926.00 -9.51473556e-01 -2.48605849e+00 2.66191449e+00 -1.93632122 0.74443119 926.25 -1.13043228e+00 -2.43303485e+00 2.68282235e+00 -2.00574004 0.69011084 926.50 -1.01622951e+00 -2.58425997e+00 2.77689071e+00 -1.94545993 0.68164465 926.75 -1.02451382e+00 -2.59090494e+00 2.78611145e+00 -1.94735428 0.72728553 927.00 -1.05100400e+00 -2.76152733e+00 2.95476608e+00 -1.93445699 0.70880661 927.25 -1.01276984e+00 -3.04561854e+00 3.20959421e+00 -1.89182675 0.77017516 927.50 -7.98473853e-01 -3.03047751e+00 3.13390402e+00 -1.82842238 0.69937088 927.75 -6.58910358e-01 -2.89737103e+00 2.97135016e+00 -1.79440976 0.62005108 928.00 -9.40112529e-02 -3.16487865e+00 3.16627462e+00 -1.60049213 0.64297515 928.25 -2.72311652e-02 -3.43094429e+00 3.43105236e+00 -1.57873309 0.74552693 928.50 -1.23244501e-01 -4.15650269e+00 4.15832945e+00 -1.60043865 0.73494647 928.75 -1.27868629e-01 -5.09545186e+00 5.09705602e+00 -1.59588572 0.79042684 929.00 -6.70750420e-01 -5.85583564e+00 5.89412565e+00 -1.68484321 0.76150236 929.25 -1.24702018e+00 -6.66280359e+00 6.77849622e+00 -1.75581723 0.77447355 929.50 -2.39679622e+00 -7.64916682e+00 8.01588331e+00 -1.87444703 0.77200202 929.75 -3.43401083e+00 -8.99684752e+00 9.62993747e+00 -1.93541966 0.76351795 930.00 -5.56961316e+00 -1.01420796e+01 1.15707549e+01 -2.07299354 0.76386212 930.25 -7.25003424e+00 -1.03626249e+01 1.26470151e+01 -2.18127593 0.76835031 930.50 -8.17959988e+00 -9.60148278e+00 1.26132599e+01 -2.27639824 0.77749753 930.75 -9.50184761e+00 -9.63653116e+00 1.35332125e+01 -2.34915725 0.77775196 931.00 -1.17562435e+01 -8.45957473e+00 1.44835653e+01 -2.51784531 0.76381448 931.25 -1.38558687e+01 -8.52255277e+00 1.62671141e+01 -2.59015419 0.75731206 931.50 -2.01444135e+01 -6.86162405e+00 2.12809605e+01 -2.81329699 0.66712038 931.75 -2.20131144e+01 -2.25076163e+00 2.21278814e+01 -3.03970034 0.60608131 932.00 -2.09109032e+01 5.02315209e+00 2.15057651e+01 2.90584261 0.57779239 932.25 -2.00992396e+01 5.88434283e+00 2.09428967e+01 2.85678713 0.52540083 932.50 -1.76190357e+01 1.84053342e+01 2.54791433e+01 2.33437111 0.56034475 932.75 -1.74922284e+01 2.21725751e+01 2.82418332e+01 2.23874013 0.62596596 933.00 -1.07215469e+01 2.54559572e+01 2.76216822e+01 1.96942718 0.71934788 933.25 -7.52035776e+00 2.65915845e+01 2.76345462e+01 1.84640855 0.72108981 933.50 4.38073873e+00 2.72202613e+01 2.75705186e+01 1.41122789 0.73556160 933.75 9.44652147e+00 2.56043437e+01 2.72913756e+01 1.21734720 0.72247494 934.00 1.43828351e+01 2.16520620e+01 2.59938018e+01 0.98445415 0.77720868 934.25 1.58350147e+01 1.89374251e+01 2.46854970e+01 0.87438293 0.75590055 934.50 1.81231028e+01 1.63855322e+01 2.44322025e+01 0.73508889 0.65716877 934.75 1.84992690e+01 1.28896710e+01 2.25469858e+01 0.60855254 0.65808132 935.00 2.00099192e+01 9.09125048e+00 2.19783462e+01 0.42645488 0.65192371 935.25 2.11766337e+01 5.00407088e+00 2.17598377e+01 0.23204501 0.61000760 935.50 2.31562362e+01 2.13251934e-01 2.31572181e+01 0.00920901 0.72690559 935.75 2.04720205e+01 -1.87209019e+00 2.05574401e+01 -0.09119265 0.71140213 936.00 1.93239459e+01 -4.00777185e+00 1.97351747e+01 -0.20449999 0.80016751 936.25 1.85471249e+01 -6.04422892e+00 1.95071409e+01 -0.31503210 0.81584945 936.50 1.74556342e+01 -8.49714235e+00 1.94139279e+01 -0.45301990 0.81588043 936.75 1.48074918e+01 -9.06308715e+00 1.73609148e+01 -0.54924066 0.78547014 937.00 1.20363147e+01 -1.05233310e+01 1.59879132e+01 -0.71843251 0.82936485 937.25 1.05418910e+01 -1.02274828e+01 1.46878477e+01 -0.77026125 0.81972770 937.50 9.60566480e+00 -9.67793229e+00 1.36356580e+01 -0.78914576 0.82637913 937.75 7.99257090e+00 -1.04378499e+01 1.31464786e+01 -0.91730403 0.81856071 938.00 7.51533619e+00 -1.06066429e+01 1.29992751e+01 -0.95435517 0.80234296 938.25 6.73733774e+00 -1.15878489e+01 1.34041024e+01 -1.04415511 0.83333737 938.50 5.24816741e+00 -1.23415725e+01 1.34111026e+01 -1.16871987 0.84416485 938.75 4.20790110e+00 -1.18220972e+01 1.25486419e+01 -1.22884380 0.78404170 939.00 2.95333616e+00 -1.12640543e+01 1.16447892e+01 -1.31437689 0.76649506 939.25 1.80779385e+00 -1.14544277e+01 1.15962077e+01 -1.41426259 0.77469445 939.50 1.02311581e+00 -1.09799802e+01 1.10275442e+01 -1.47788450 0.69241852 939.75 -9.92868187e-01 -1.03820712e+01 1.04294386e+01 -1.66613933 0.75665349 940.00 -8.64196287e-01 -9.94599554e+00 9.98346946e+00 -1.65746752 0.75484002 940.25 -1.83391201e+00 -9.86032303e+00 1.00294169e+01 -1.75468423 0.80856580 940.50 -1.85533035e+00 -9.84099017e+00 1.00143566e+01 -1.75713994 0.82969067 940.75 -2.04537828e+00 -8.31813557e+00 8.56591803e+00 -1.81190665 0.75982044 941.00 -2.78796332e+00 -8.12333503e+00 8.58844057e+00 -1.90140427 0.77946925 941.25 -3.23906020e+00 -8.02105714e+00 8.65036812e+00 -1.95459113 0.75892490 941.50 -3.89850236e+00 -8.57806369e+00 9.42239340e+00 -1.99736416 0.77286218 941.75 -5.31460375e+00 -8.42883680e+00 9.96445196e+00 -2.13335978 0.79347363 942.00 -5.52921186e+00 -7.55930428e+00 9.36564280e+00 -2.20231579 0.82109277 942.25 -5.36328481e+00 -7.10250657e+00 8.90002379e+00 -2.21756978 0.82695387 942.50 -5.78232901e+00 -6.52477964e+00 8.71826119e+00 -2.29594054 0.79411104 942.75 -6.04080157e+00 -5.06676634e+00 7.88437726e+00 -2.44366188 0.67510672 943.00 -6.32375577e+00 -4.70994020e+00 7.88501260e+00 -2.50142716 0.70896040 943.25 -7.39288237e+00 -4.28441783e+00 8.54464428e+00 -2.61635853 0.81954694 943.50 -7.57881317e+00 -3.76756993e+00 8.46362761e+00 -2.68025272 0.81165235 943.75 -7.01234461e+00 -2.83257186e+00 7.56283282e+00 -2.75769369 0.76388598 944.00 -6.24507412e+00 -1.90578014e+00 6.52939114e+00 -2.84540378 0.73379715 944.25 -6.27785648e+00 -7.64570927e-01 6.32424310e+00 -3.02040096 0.81707785 944.50 -6.40661278e+00 -6.24778818e-01 6.43700519e+00 -3.04437913 0.83533894 944.75 -6.19041900e+00 -1.65916937e-01 6.19264207e+00 -3.11479685 0.87342840 945.00 -5.90126274e+00 3.66021823e-02 5.90137625e+00 3.13539030 0.86110347 945.25 -5.50763444e+00 6.77318853e-01 5.54912587e+00 3.01922887 0.89182948 945.50 -5.18022202e+00 9.14303385e-01 5.26029000e+00 2.96689302 0.89136693 945.75 -4.59713759e+00 1.14248795e+00 4.73697717e+00 2.89800592 0.87424370 946.00 -4.31938099e+00 9.95945018e-01 4.43271459e+00 2.91497740 0.89584286 946.25 -3.96779866e+00 1.20779698e+00 4.14755346e+00 2.84610428 0.91041678 946.50 -3.75316654e+00 1.54601825e+00 4.05911708e+00 2.75084967 0.91576685 946.75 -3.47034763e+00 1.66569303e+00 3.84939553e+00 2.69408997 0.91668149 947.00 -3.29548007e+00 1.67662814e+00 3.69746817e+00 2.67095688 0.88688102 947.25 -2.85122745e+00 1.81650162e+00 3.38070645e+00 2.57434333 0.88980605 947.50 -2.52130684e+00 1.70100492e+00 3.04144800e+00 2.54808204 0.86379820 947.75 -2.13163815e+00 1.68964448e+00 2.72006979e+00 2.47134908 0.85168803 948.00 -2.02661490e+00 1.66348015e+00 2.62189515e+00 2.45428662 0.83706496 948.25 -1.72582350e+00 1.62069523e+00 2.36751342e+00 2.38759838 0.83832707 948.50 -1.59655443e+00 1.58143784e+00 2.24720531e+00 2.36095110 0.86145237 948.75 -1.53898231e+00 1.44770667e+00 2.11289402e+00 2.38674579 0.86699715 949.00 -1.51525426e+00 1.20314827e+00 1.93482848e+00 2.47050624 0.85846682 949.25 -1.45226401e+00 1.05605386e+00 1.79563931e+00 2.51285859 0.85035192 949.50 -1.41775967e+00 1.05918051e+00 1.76971914e+00 2.49996269 0.76052726 949.75 -1.29436398e+00 1.08650702e+00 1.68993361e+00 2.44327660 0.75980370 950.00 -1.24859360e+00 1.05238783e+00 1.63294400e+00 2.44125919 0.85761903 950.25 -1.12725213e+00 1.04361858e+00 1.53617613e+00 2.39470079 0.87356272 950.50 -8.40794054e-01 8.18499406e-01 1.17340356e+00 2.36962991 0.72740048 950.75 -8.17265349e-01 6.81016136e-01 1.06381654e+00 2.44688205 0.69659277 951.00 -7.67720928e-01 6.22628893e-01 9.88464548e-01 2.46017462 0.74780067 951.25 -7.47320215e-01 5.80936572e-01 9.46559456e-01 2.48081007 0.77642765 951.50 -8.77945575e-01 5.45361362e-01 1.03354122e+00 2.58574574 0.82466661 951.75 -9.13588325e-01 4.91827812e-01 1.03756360e+00 2.64773985 0.82027951 952.00 -9.22270525e-01 4.74322917e-01 1.03709457e+00 2.66657130 0.84517550 952.25 -9.23983634e-01 5.35546251e-01 1.06796795e+00 2.61630390 0.87008415 952.50 -9.08700440e-01 5.83800659e-01 1.08007393e+00 2.57053859 0.87176933 952.75 -8.97126715e-01 5.76657503e-01 1.06647561e+00 2.57030787 0.86432329 953.00 -9.27951700e-01 6.87952283e-01 1.15515051e+00 2.50363994 0.88564732 953.25 -9.60556997e-01 7.47590553e-01 1.21719406e+00 2.48023129 0.89148250 953.50 -9.53265586e-01 7.98966132e-01 1.24380953e+00 2.44402675 0.88511097 953.75 -8.88263366e-01 8.44753025e-01 1.22581380e+00 2.38129593 0.88983673 954.00 -7.68297353e-01 9.40976331e-01 1.21479104e+00 2.25551132 0.88698718 954.25 -6.93799734e-01 9.35067493e-01 1.16434930e+00 2.20914371 0.88155974 954.50 -5.60835418e-01 8.84096458e-01 1.04697799e+00 2.13609812 0.86070732 954.75 -5.14662142e-01 8.61152241e-01 1.00322495e+00 2.10948139 0.83444999 955.00 -4.16700587e-01 8.78175634e-01 9.72024600e-01 2.01384244 0.84644583 955.25 -4.17053600e-01 8.01368397e-01 9.03396376e-01 2.05065153 0.81795028 955.50 -3.50599165e-01 7.08917917e-01 7.90875710e-01 2.03007876 0.69546315 955.75 -2.48831614e-01 7.29414969e-01 7.70690190e-01 1.89955511 0.66395245 956.00 -2.19310363e-01 7.19202611e-01 7.51897221e-01 1.86677487 0.72536928 956.25 -2.42258555e-01 6.53747905e-01 6.97191172e-01 1.92567643 0.62075388 956.50 -2.56221976e-01 5.46783134e-01 6.03838966e-01 2.00900900 0.44607562 956.75 -1.41156485e-01 5.26407269e-01 5.45004372e-01 1.83278373 0.41088941 957.00 -2.58840956e-02 4.62367927e-01 4.63091877e-01 1.62671955 0.43378005 957.25 -6.97339382e-02 4.54232425e-01 4.59554042e-01 1.72312741 0.46800234 957.50 -4.33344152e-02 4.66523222e-01 4.68531523e-01 1.66341856 0.46410812 957.75 3.37762168e-02 3.77690074e-01 3.79197343e-01 1.48160519 0.31832476 958.00 5.14735295e-02 3.60583717e-01 3.64239126e-01 1.42900372 0.30684184 958.25 7.40749680e-02 3.08185757e-01 3.16963029e-01 1.33491270 0.27118572 958.50 1.20791489e-01 2.24555874e-01 2.54982203e-01 1.07728042 0.24637832 958.75 8.34354851e-02 1.67739331e-01 1.87344504e-01 1.10922160 0.12449819 959.00 2.91776359e-02 8.39763484e-02 8.89008522e-02 1.23639446 0.03481896 959.25 -1.07548544e-01 -4.39089893e-02 1.16166642e-01 -2.75397620 0.05658112 959.50 -1.56420344e-01 -4.18932560e-02 1.61933224e-01 -2.87990928 0.12053564 959.75 -2.49370577e-01 1.30795913e-01 2.81590582e-01 2.65853441 0.29188915 960.00 -2.65859100e-01 1.59474812e-01 3.10021413e-01 2.60128558 0.39097876 960.25 -2.61395540e-01 1.14337834e-01 2.85308200e-01 2.72925515 0.33713813 960.50 -2.39143534e-01 8.05004813e-02 2.52329065e-01 2.81688708 0.33505218 960.75 -2.60597235e-01 1.37812336e-01 2.94793417e-01 2.65514584 0.42387502 961.00 -2.52475301e-01 2.09211986e-01 3.27892410e-01 2.44962861 0.48618002 961.25 -1.91148087e-01 1.78080556e-01 2.61247537e-01 2.39157116 0.46246279 961.50 -1.89878767e-01 1.36382860e-01 2.33782443e-01 2.51871462 0.46032771 961.75 -2.43498133e-01 1.22229534e-01 2.72454399e-01 2.67636774 0.53841914 962.00 -2.49054135e-01 1.18242019e-01 2.75697547e-01 2.69833662 0.54941134 962.25 -2.19768180e-01 1.76006446e-01 2.81560513e-01 2.46631950 0.53039340 962.50 -2.36550280e-01 2.39041335e-01 3.36298669e-01 2.35095674 0.60061737 962.75 -2.31595274e-01 3.18872495e-01 3.94101560e-01 2.19895237 0.70356719 963.00 -1.76812432e-01 3.36180241e-01 3.79841797e-01 2.05498412 0.68672985 963.25 -1.11107011e-01 2.85571311e-01 3.06424120e-01 1.94184426 0.54324335 963.50 -7.66660486e-02 2.76750930e-01 2.87173746e-01 1.84104124 0.50869169 963.75 -1.95685599e-02 2.26053601e-01 2.26899006e-01 1.65714708 0.31158332 964.00 1.58762586e-02 1.61717231e-01 1.62494672e-01 1.47293695 0.20166319 964.25 3.14839142e-02 1.06058087e-01 1.10632521e-01 1.28222699 0.13106468 964.50 1.98030985e-02 1.15309336e-01 1.16997460e-01 1.40071660 0.13892701 964.75 5.83385664e-02 1.51403574e-01 1.62254216e-01 1.20301031 0.18774151 965.00 3.93542397e-02 1.41284091e-01 1.46662710e-01 1.29913563 0.13508639 965.25 -8.19153142e-02 8.51055171e-02 1.18123104e-01 2.33709618 0.08778254 965.50 -7.81733284e-02 9.91378032e-02 1.26251231e-01 2.23850535 0.07543985 965.75 3.42760470e-02 1.46673540e-01 1.50625279e-01 1.34122677 0.07134531 966.00 1.15506221e-02 9.66943259e-02 9.73817721e-02 1.45190468 0.02470825 966.25 -4.05162843e-02 6.27959937e-02 7.47322294e-02 2.14379328 0.01411641 966.50 6.87212974e-02 6.84258344e-02 9.69778920e-02 0.78324382 0.02510753 966.75 2.12441333e-01 6.06733955e-03 2.12527957e-01 0.02855231 0.16692028 967.00 1.75547361e-01 -5.60575806e-02 1.84280570e-01 -0.30909528 0.12922758 967.25 9.75257891e-02 -9.02320108e-02 1.32864951e-01 -0.74657095 0.05506764 967.50 5.73835333e-02 -1.57782651e-01 1.67893523e-01 -1.22198041 0.09270445 967.75 1.46468136e-02 -1.90778708e-01 1.91340128e-01 -1.49417280 0.12925582 968.00 -9.53059007e-02 -2.07352569e-01 2.28206710e-01 -2.00163139 0.17267032 968.25 -1.51306521e-01 -1.78540998e-01 2.34031090e-01 -2.27381448 0.22224302 968.50 -1.63448623e-01 -1.65649032e-01 2.32712386e-01 -2.34950840 0.22202749 968.75 -1.50170319e-01 -1.17427947e-01 1.90631707e-01 -2.47794576 0.16832632 969.00 -1.53863770e-01 -1.42323803e-01 2.09595145e-01 -2.39513648 0.13032692 969.25 -1.31118186e-01 -1.30088315e-01 1.84702324e-01 -2.36013721 0.09134034 969.50 -2.17553140e-01 -8.50918533e-02 2.33602210e-01 -2.76875497 0.15402130 969.75 -2.18741273e-01 -5.45531760e-02 2.25441331e-01 -2.89718264 0.13633701 970.00 -3.17159178e-01 -5.97431472e-02 3.22737026e-01 -2.95540477 0.29033534 970.25 -3.44768156e-01 -3.19473039e-02 3.46245161e-01 -3.04919336 0.30127743 970.50 -3.44095016e-01 -7.35778466e-02 3.51873670e-01 -2.93093504 0.21043156 970.75 -2.45014269e-01 -4.22397601e-02 2.48628617e-01 -2.97087361 0.09946353 971.00 -3.37688772e-01 2.40771615e-02 3.38546033e-01 3.07041325 0.17980911 971.25 -2.74491736e-01 9.06616822e-02 2.89076554e-01 2.82258423 0.14003025 971.50 -1.11618553e-01 8.49777456e-02 1.40285133e-01 2.49088427 0.03041646 971.75 -1.01680102e-01 9.99120971e-02 1.42552693e-01 2.36496447 0.02884373 972.00 2.49575482e-02 2.54669025e-01 2.55889022e-01 1.47310833 0.10183453 972.25 1.34037713e-01 2.34668483e-01 2.70250634e-01 1.05183836 0.09881709 972.50 1.37900737e-01 4.24962372e-01 4.46776936e-01 1.25701578 0.24382924 972.75 1.35164624e-01 4.24220603e-01 4.45233193e-01 1.26234686 0.26324160 973.00 1.30414771e-01 2.40415080e-01 2.73509457e-01 1.07376296 0.18552452 973.25 1.31118053e-01 2.46811137e-01 2.79477514e-01 1.08246353 0.26642156 973.50 2.10180754e-01 1.70349551e-01 2.70545595e-01 0.68110507 0.22508499 973.75 2.21101213e-01 1.70990524e-01 2.79505824e-01 0.65828378 0.18242637 974.00 2.29985852e-01 2.48615769e-01 3.38678746e-01 0.82430425 0.27734805 974.25 2.79648550e-01 1.61835847e-01 3.23100840e-01 0.52461914 0.33805401 974.50 1.73931924e-01 9.70653568e-02 1.99183326e-01 0.50901422 0.25893304 974.75 1.71451339e-01 9.45685802e-02 1.95802906e-01 0.50405300 0.24384872 975.00 1.54087632e-01 3.42656828e-02 1.57851625e-01 0.21881728 0.13977363 975.25 1.21159541e-01 1.86298530e-02 1.22583464e-01 0.15256808 0.09876443 975.50 1.03040940e-01 7.47111618e-02 1.27276050e-01 0.62734941 0.10162804 975.75 7.10562533e-02 7.73822761e-02 1.05057164e-01 0.82798951 0.05954677 976.00 5.60900240e-02 -1.87368063e-02 5.91367796e-02 -0.32239435 0.01456780 976.25 6.25437808e-02 2.11857984e-02 6.60345559e-02 0.32660459 0.01666929 976.50 3.17604984e-02 2.34313950e-01 2.36456669e-01 1.43607066 0.14251644 976.75 7.25185058e-02 2.23582623e-01 2.35049192e-01 1.25715454 0.15022564 977.00 8.38110173e-02 2.32799983e-01 2.47426997e-01 1.22522925 0.17451337 977.25 1.45711594e-01 3.62998687e-01 3.91152036e-01 1.18907433 0.33962873 977.50 2.50561324e-01 3.39960070e-01 4.22319579e-01 0.93564677 0.38436260 977.75 3.03657839e-01 3.29825486e-01 4.48322355e-01 0.82668225 0.41235820 978.00 3.88549936e-01 3.21439773e-01 5.04276294e-01 0.69115544 0.42991516 978.25 4.12815202e-01 2.17826994e-01 4.66760099e-01 0.48553172 0.37219347 978.50 3.63109429e-01 2.05425112e-01 4.17190524e-01 0.51484643 0.38053150 978.75 5.09397668e-01 3.03723926e-01 5.93071840e-01 0.53765116 0.48904431 979.00 6.14421989e-01 2.49926265e-01 6.63308012e-01 0.38632590 0.50447130 979.25 5.08566205e-01 9.59701236e-02 5.17542123e-01 0.18651393 0.35546887 979.50 5.04390347e-01 5.76607325e-02 5.07675470e-01 0.11382356 0.36948090 979.75 5.27839665e-01 -2.15502105e-02 5.28279399e-01 -0.04080453 0.41579747 980.00 5.80835268e-01 1.42441334e-03 5.80837014e-01 0.00245235 0.45285897 980.25 5.42022983e-01 -1.18499082e-01 5.54825150e-01 -0.21523719 0.38768569 980.50 4.75162768e-01 -1.29571797e-01 4.92512443e-01 -0.26621669 0.36451456 980.75 4.47922148e-01 -2.53027387e-01 5.14448354e-01 -0.51420425 0.37985173 981.00 4.53053239e-01 -2.63007281e-01 5.23860733e-01 -0.52597416 0.42701349 981.25 5.15556765e-01 -3.88625981e-01 6.45622901e-01 -0.64592780 0.43670939 981.50 6.06219862e-01 -5.35153311e-01 8.08635633e-01 -0.72321436 0.63318496 981.75 5.36377818e-01 -4.95202276e-01 7.30018121e-01 -0.74550432 0.41721477 982.00 4.82943150e-01 -5.08501896e-01 7.01290428e-01 -0.81117174 0.32331526 982.25 3.70310704e-01 -8.28828910e-01 9.07792587e-01 -1.15061682 0.46102003 982.50 3.31555796e-01 -8.67555598e-01 9.28752907e-01 -1.20575241 0.41480520 982.75 -1.39110450e-02 -9.31098397e-01 9.31202310e-01 -1.58573568 0.46139544 983.00 -8.02165894e-02 -1.01642125e+00 1.01958171e+00 -1.64955370 0.51602695 983.25 -3.19642713e-01 -7.10836396e-01 7.79397104e-01 -1.99337686 0.25872275 983.50 -2.23355833e-01 -6.18644378e-01 6.57729956e-01 -1.91727295 0.17415812 983.75 -2.10505554e-01 -5.82722729e-01 6.19579185e-01 -1.91745345 0.21869364 984.00 -3.34125484e-01 -5.04646330e-01 6.05233638e-01 -2.15562955 0.23601737 984.25 -5.19061322e-01 -2.68396483e-01 5.84346924e-01 -2.66437421 0.13492662 984.50 -4.40621559e-01 -1.38428688e-01 4.61854804e-01 -2.83718995 0.06551872 984.75 -1.34683102e-01 -3.79650821e-01 4.02832824e-01 -1.91170111 0.06279562 985.00 -1.67192702e-01 -5.41456500e-01 5.66682046e-01 -1.87029155 0.12976249 985.25 -4.23208550e-01 -7.58870690e-01 8.68901722e-01 -2.07951831 0.24993607 985.50 -5.75150076e-01 -8.76717177e-01 1.04853737e+00 -2.15139674 0.24975915 985.75 -4.87272003e-01 -8.30863021e-01 9.63206813e-01 -2.10120410 0.20318260 986.00 -4.83730275e-01 -6.82915759e-01 8.36880465e-01 -2.18709159 0.15862792 986.25 -8.17655499e-01 -8.05982226e-01 1.14811492e+00 -2.36338395 0.31520411 986.50 -9.91855424e-01 -9.95023541e-01 1.40493738e+00 -2.35459997 0.48767140 986.75 -1.05747981e+00 -9.98312514e-01 1.45426663e+00 -2.38496732 0.58470986 987.00 -1.12013207e+00 -9.11595474e-01 1.44419603e+00 -2.45847636 0.59326833 987.25 -1.36898488e+00 -8.99162718e-01 1.63786849e+00 -2.56044510 0.66562586 987.50 -1.30793052e+00 -7.67020251e-01 1.51624613e+00 -2.61120485 0.62062875 987.75 -1.14206680e+00 -6.18077806e-01 1.29859029e+00 -2.64553670 0.54097345 988.00 -1.08413041e+00 -4.39577646e-01 1.16985779e+00 -2.75638340 0.45410789 988.25 -9.56843169e-01 -3.88549530e-01 1.03272435e+00 -2.75586071 0.36669365 988.50 -9.15436878e-01 -3.24704326e-01 9.71317444e-01 -2.80073800 0.24341503 988.75 -1.33641756e+00 7.63986976e-02 1.33859951e+00 3.08448802 0.33861546 989.00 -1.27863400e+00 1.99028026e-01 1.29403132e+00 2.98717507 0.37981226 989.25 -1.29704491e+00 4.76027208e-01 1.38163939e+00 2.78984610 0.41039689 989.50 -1.42807558e+00 9.45951975e-01 1.71295797e+00 2.55655229 0.51329840 989.75 -1.43130804e+00 1.04374684e+00 1.77145426e+00 2.51152010 0.53639409 990.00 -1.16627929e+00 1.26099697e+00 1.71764977e+00 2.31719207 0.43846491 990.25 -8.79842875e-01 1.56135513e+00 1.79219232e+00 2.08395447 0.45697660 990.50 -6.13948281e-01 1.40499694e+00 1.53328044e+00 1.98276587 0.56162278 990.75 -5.89744813e-01 1.43611226e+00 1.55248747e+00 1.96045306 0.57731632 991.00 -4.04822882e-01 1.40068705e+00 1.45801433e+00 1.85214711 0.52198987 991.25 -1.79294726e-01 1.37952916e+00 1.39113166e+00 1.70003992 0.52216387 991.50 -9.97782527e-02 1.44264104e+00 1.44608743e+00 1.63984996 0.56793795 991.75 -6.02867302e-02 1.31172570e+00 1.31311035e+00 1.61672387 0.62066223 992.00 1.05711262e-01 1.27832385e+00 1.28268731e+00 1.48828885 0.73242531 992.25 1.89765528e-01 1.15472072e+00 1.17020977e+00 1.40791336 0.67964450 992.50 6.81620533e-02 1.23518599e+00 1.23706527e+00 1.51566860 0.70507110 992.75 -8.50895856e-02 1.20683465e+00 1.20983061e+00 1.64118626 0.67791938 993.00 -4.93004196e-02 1.16117998e+00 1.16222609e+00 1.61322802 0.65773437 993.25 4.29633852e-02 1.10163493e+00 1.10247239e+00 1.53181642 0.64468601 993.50 9.26216551e-02 1.01152823e+00 1.01575988e+00 1.47948489 0.63736964 993.75 1.00020575e-01 8.96092801e-01 9.01657597e-01 1.45963789 0.60945771 994.00 8.25924119e-02 8.31604331e-01 8.35695680e-01 1.47180400 0.61698363 994.25 1.68374271e-01 7.63086445e-01 7.81441500e-01 1.35362705 0.63100638 994.50 3.00941902e-01 8.06211437e-01 8.60548028e-01 1.21353522 0.58661650 994.75 2.51869427e-01 8.19847594e-01 8.57664436e-01 1.27273354 0.60108197 995.00 2.14691772e-01 7.98185252e-01 8.26554446e-01 1.30804022 0.51932148 995.25 2.41691193e-01 7.76860831e-01 8.13589198e-01 1.26917592 0.46749046 995.50 1.76768639e-01 7.63023645e-01 7.83231916e-01 1.34314373 0.56849962 995.75 1.83125898e-01 7.70771415e-01 7.92227031e-01 1.33753340 0.60496087 996.00 4.21079699e-01 8.17345234e-01 9.19435340e-01 1.09507881 0.56178911 996.25 4.89507624e-01 6.82563738e-01 8.39947005e-01 0.94864598 0.47260625 996.50 4.91746163e-01 6.49435325e-01 8.14604524e-01 0.92270925 0.57940014 996.75 5.40947491e-01 5.57701040e-01 7.76952147e-01 0.80064622 0.54627445 997.00 5.69306173e-01 4.97460040e-01 7.56026461e-01 0.71815025 0.49382629 997.25 6.34422967e-01 4.12309791e-01 7.56631921e-01 0.57630304 0.48257079 997.50 6.18230347e-01 2.37409175e-01 6.62247596e-01 0.36664993 0.54963919 997.75 6.52770347e-01 2.15883496e-01 6.87542587e-01 0.31939573 0.51000295 998.00 6.73240153e-01 1.13779022e-01 6.82786914e-01 0.16742016 0.41885558 998.25 6.32179404e-01 2.96054792e-03 6.32186337e-01 0.00468305 0.39201212 998.50 5.60545673e-01 -3.90990286e-02 5.61907631e-01 -0.06963893 0.37755049 998.75 4.57223028e-01 -2.79980177e-01 5.36135987e-01 -0.54945038 0.28067874 999.00 3.14319837e-01 -4.59578226e-01 5.56784614e-01 -0.97093647 0.28774422 999.25 1.86548425e-01 -4.40646131e-01 4.78507396e-01 -1.17032237 0.19219406 999.50 -1.69542430e-01 -3.76200815e-01 4.12639902e-01 -1.99420731 0.13003398 999.75 -3.33192106e-01 -2.84796648e-01 4.38321926e-01 -2.43434622 0.13365795 1000.00 -2.91332532e-01 0.00000000e+00 2.91332532e-01 3.14159265 0.06973289