========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0055 Injection acquisition : SIG0056 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 3.74311592e-04 0.00000000e+00 3.74311592e-04 0.00000000 0.00009880 0.25 5.21708182e-04 4.83015653e-03 4.85824985e-03 1.46320282 0.01719303 0.50 2.26206545e-03 2.55641846e-03 3.41353415e-03 0.84641065 0.01297398 0.75 2.50327597e-03 -5.05882416e-04 2.55388089e-03 -0.19940259 0.00671774 1.00 1.47593999e-03 -2.17806810e-03 2.63104152e-03 -0.97523714 0.00668181 1.25 1.45219363e-03 -2.45898782e-03 2.85578141e-03 -1.03734276 0.00724612 1.50 5.38838409e-04 -2.59943017e-03 2.65469095e-03 -1.36640015 0.00490874 1.75 -3.61438077e-04 -4.75476275e-03 4.76848050e-03 -1.64666642 0.01432662 2.00 4.02552185e-04 -5.63201087e-03 5.64637890e-03 -1.49944193 0.01696822 2.25 1.48651883e-03 -6.65579667e-03 6.81977767e-03 -1.35106057 0.02339697 2.50 8.86208617e-04 -5.87184314e-03 5.93834216e-03 -1.42100174 0.01472191 2.75 2.91508301e-03 -9.98727590e-03 1.04040083e-02 -1.28680591 0.04391507 3.00 4.73059259e-03 -1.33849560e-02 1.41963218e-02 -1.23107258 0.06381251 3.25 4.22897969e-03 -1.32025198e-02 1.38632896e-02 -1.26080667 0.06519663 3.50 3.40411834e-03 -1.13789216e-02 1.18772000e-02 -1.28011034 0.04098273 3.75 3.64168935e-03 -1.14762689e-02 1.20402097e-02 -1.26352319 0.03463762 4.00 5.68870506e-03 -1.39108079e-02 1.50290366e-02 -1.18260570 0.04847963 4.25 1.56302998e-03 -1.06915602e-02 1.08052081e-02 -1.42563179 0.02384657 4.50 3.95978247e-03 -1.16366047e-02 1.22918854e-02 -1.24280080 0.02731647 4.75 9.08286732e-04 -1.59080288e-02 1.59339375e-02 -1.51376213 0.04595997 5.00 -6.01143623e-04 -1.53858464e-02 1.53975856e-02 -1.60984767 0.03732604 5.25 4.39549385e-03 -1.80186809e-02 1.85470544e-02 -1.33152839 0.05546204 5.50 6.79350549e-03 -2.07162150e-02 2.18016807e-02 -1.25391501 0.07022809 5.75 1.82608933e-03 -1.48151883e-02 1.49273040e-02 -1.44815697 0.02925714 6.00 1.70750023e-04 -1.56492547e-02 1.56501862e-02 -1.55988570 0.02903765 6.25 -4.19375594e-03 -2.48946841e-02 2.52454528e-02 -1.73768926 0.07278914 6.50 -4.70793525e-03 -2.46419523e-02 2.50876556e-02 -1.75957503 0.06593936 6.75 -7.30975952e-04 -1.88474459e-02 1.88616156e-02 -1.60956072 0.03392572 7.00 3.07147476e-03 -2.03031362e-02 2.05341495e-02 -1.42065400 0.03865502 7.25 9.57499102e-04 -2.63768330e-02 2.63942063e-02 -1.53451150 0.06074366 7.50 1.96798428e-04 -2.56912240e-02 2.56919778e-02 -1.56313633 0.05606029 7.75 -3.73442062e-04 -3.26726747e-02 3.26748088e-02 -1.58222563 0.07449783 8.00 -4.91993655e-03 -3.07488137e-02 3.11399313e-02 -1.72945560 0.07017375 8.25 -8.10321825e-03 -2.23107002e-02 2.37366697e-02 -1.91918076 0.04032454 8.50 -7.14103449e-05 -2.41071793e-02 2.41072851e-02 -1.57375852 0.03833791 8.75 1.09416277e-03 -2.92621832e-02 2.92826323e-02 -1.53342204 0.06026058 9.00 1.01253087e-03 -3.00222180e-02 3.00392874e-02 -1.53708305 0.05881898 9.25 -7.78217215e-04 -3.04344672e-02 3.04444152e-02 -1.59636102 0.05115277 9.50 1.46340270e-03 -3.28939819e-02 3.29265181e-02 -1.52633718 0.06280560 9.75 2.75902562e-03 -3.38650195e-02 3.39772243e-02 -1.48950461 0.05675436 10.00 4.38694806e-03 -3.64985356e-02 3.67612352e-02 -1.45117500 0.06787089 10.25 1.95073340e-04 -4.12700366e-02 4.12704976e-02 -1.56606961 0.08080284 10.50 -2.79115641e-03 -3.91304161e-02 3.92298358e-02 -1.64200531 0.07139046 10.75 1.01553046e-03 -4.22619347e-02 4.22741343e-02 -1.54677151 0.07183187 11.00 3.04205525e-03 -3.95100810e-02 3.96270186e-02 -1.49395353 0.06957279 11.25 -3.69059195e-03 -3.78624643e-02 3.80419068e-02 -1.66796301 0.05905291 11.50 -2.34656272e-04 -4.00653343e-02 4.00660215e-02 -1.57665310 0.06424098 11.75 -4.24694089e-03 -4.29551927e-02 4.31646278e-02 -1.66934514 0.06100551 12.00 3.64560642e-03 -3.88270541e-02 3.89978278e-02 -1.47717734 0.05455003 12.25 6.33982178e-03 -3.33444648e-02 3.39418130e-02 -1.38290779 0.03793895 12.50 6.80368382e-03 -4.48988090e-02 4.54113770e-02 -1.42040674 0.06872498 12.75 2.98751262e-03 -5.76619462e-02 5.77392871e-02 -1.51903179 0.09848455 13.00 -9.03238250e-03 -5.51968927e-02 5.59310370e-02 -1.73299805 0.08527146 13.25 -1.32700504e-02 -6.40304306e-02 6.53910566e-02 -1.77514938 0.09993129 13.50 -1.54130847e-02 -6.23868974e-02 6.42626498e-02 -1.81300267 0.09056385 13.75 -1.47414027e-02 -5.27680067e-02 5.47884247e-02 -1.84321379 0.05352519 14.00 -7.20532850e-03 -3.35809378e-02 3.43452492e-02 -1.78215765 0.01528736 14.25 -1.97763681e-02 -3.59943710e-02 4.10694470e-02 -2.07320140 0.02040223 14.50 -8.67820820e-03 -4.46443725e-02 4.54800099e-02 -1.76278732 0.03701318 14.75 -1.14941227e-02 -5.80434236e-02 5.91705491e-02 -1.76629335 0.04840329 15.00 -5.95823202e-03 -4.55508440e-02 4.59388716e-02 -1.70086188 0.02618350 15.25 -8.91683869e-03 -4.87857615e-02 4.95939566e-02 -1.75157629 0.02957385 15.50 -9.28302250e-03 -5.16267950e-02 5.24547469e-02 -1.74870538 0.03458989 15.75 -5.77268123e-03 -4.98835983e-02 5.02165036e-02 -1.68600689 0.03511048 16.00 -9.36509003e-03 -1.37103984e-02 1.66036121e-02 -2.17006571 0.00493027 16.25 -9.73362839e-03 -2.27327587e-02 2.47289677e-02 -1.97535424 0.01116280 16.50 -5.78109389e-03 -6.08956872e-02 6.11694840e-02 -1.66544703 0.05758372 16.75 -1.31489699e-02 -6.42357320e-02 6.55677106e-02 -1.77270574 0.06378636 17.00 1.10827257e-03 -5.83148075e-02 5.83253379e-02 -1.55179362 0.03346939 17.25 1.13966820e-02 -6.22120016e-02 6.32472727e-02 -1.38961421 0.04422989 17.50 -2.17589859e-02 -6.64620546e-02 6.99332408e-02 -1.88718802 0.05375743 17.75 -2.26717192e-02 -6.01122114e-02 6.42455042e-02 -1.93145640 0.05221385 18.00 -2.02253641e-03 -7.36787213e-02 7.37064761e-02 -1.59824019 0.06961511 18.25 4.80505336e-03 -6.75395382e-02 6.77102486e-02 -1.49977169 0.06074446 18.50 6.27574365e-03 -3.01344767e-02 3.07810273e-02 -1.36547321 0.01099712 18.75 8.34186701e-03 -4.89704687e-02 4.96758850e-02 -1.40207103 0.02958857 19.00 -1.60884138e-03 -5.16085222e-02 5.16335931e-02 -1.60196018 0.02367330 19.25 -4.89883951e-03 -4.56450263e-02 4.59071569e-02 -1.67771179 0.02141997 19.50 -3.58396241e-02 -5.31495966e-02 6.41042766e-02 -2.16407595 0.03409527 19.75 -1.85749123e-02 -6.54789481e-02 6.80626183e-02 -1.84721202 0.04018060 20.00 -1.08513534e-02 -6.68707903e-02 6.77455125e-02 -1.73166750 0.04041309 20.25 -1.00013197e-02 -8.57514770e-02 8.63327412e-02 -1.68690322 0.07026012 20.50 -2.30920712e-02 -1.07288094e-01 1.09745063e-01 -1.78279637 0.09793843 20.75 -2.41979930e-02 -9.22379000e-02 9.53591792e-02 -1.82735803 0.07851253 21.00 -7.06591458e-02 -9.40898226e-02 1.17667369e-01 -2.21492142 0.08518320 21.25 -3.30994077e-02 -9.18571968e-02 9.76386983e-02 -1.91664887 0.06422761 21.50 -3.40317230e-02 -9.31590464e-02 9.91804723e-02 -1.92104274 0.06689234 21.75 -7.63533592e-03 -8.78841320e-02 8.82151859e-02 -1.65745829 0.04512504 22.00 -1.24237680e-02 -5.33994381e-02 5.48256327e-02 -1.79938702 0.01271744 22.25 -1.52831091e-02 -4.09913713e-02 4.37477536e-02 -1.92766952 0.00955297 22.50 -6.10988371e-02 -1.14227469e-03 6.11095139e-02 -3.12289931 0.01296595 22.75 -4.07564268e-02 -4.03351770e-02 5.73411966e-02 -2.36138918 0.01329486 23.00 -6.13833684e-02 -8.86812157e-02 1.07853029e-01 -2.17625470 0.03592844 23.25 -1.01574576e-01 -9.70345416e-02 1.40474541e-01 -2.37904965 0.07767904 23.50 -1.32643179e-01 -5.70771932e-02 1.44402282e-01 -2.73523614 0.07397597 23.75 -1.62384837e-01 -4.80707955e-02 1.69350633e-01 -2.85378196 0.08572740 24.00 -1.92710793e-01 -1.86111458e-02 1.93607398e-01 -3.04531571 0.09811016 24.25 -1.07443275e-01 -2.25102636e-02 1.09775996e-01 -2.93507139 0.03780006 24.50 -1.36877790e-01 -5.05699036e-02 1.45920679e-01 -2.78769400 0.06235637 24.75 -1.76770227e-01 -9.48958869e-02 2.00631359e-01 -2.64891553 0.09844228 25.00 -1.65663128e-01 -9.61248859e-02 1.91531370e-01 -2.61582698 0.09204106 25.25 -1.01377710e-01 -6.48791019e-02 1.20360866e-01 -2.57229789 0.05840128 25.50 -8.70461078e-02 -8.50197678e-02 1.21677384e-01 -2.36797048 0.05803875 25.75 -7.73607023e-02 -4.38757113e-02 8.89368107e-02 -2.62567211 0.02715118 26.00 -9.52100668e-02 -2.24672842e-02 9.78250259e-02 -2.90985604 0.03211158 26.25 -1.03858545e-01 -9.30312720e-02 1.39432474e-01 -2.41113069 0.07551199 26.50 -6.88556529e-02 -7.78534369e-02 1.03933914e-01 -2.29494043 0.04815473 26.75 -3.06476989e-02 -8.88657042e-02 9.40021001e-02 -1.90289957 0.04525347 27.00 -2.91888519e-02 -8.66506781e-02 9.14348352e-02 -1.89571445 0.04464353 27.25 -4.63675718e-02 -8.20230307e-02 9.42217028e-02 -2.08530981 0.04055981 27.50 -3.14896001e-02 -8.95609270e-02 9.49355285e-02 -1.90889561 0.04322080 27.75 -7.20344935e-02 -7.91161793e-02 1.06996907e-01 -2.30937690 0.05080932 28.00 -5.72669504e-02 -9.46336595e-02 1.10612084e-01 -2.11498928 0.05505805 28.25 -5.64773281e-02 -1.41696247e-01 1.52536930e-01 -1.95007820 0.09876833 28.50 -2.12914501e-02 -1.40477748e-01 1.42082101e-01 -1.72121607 0.09133765 28.75 -1.57242126e-02 -1.02318651e-01 1.03519840e-01 -1.72328222 0.04474318 29.00 -1.38190493e-02 -9.21474490e-02 9.31778862e-02 -1.71965371 0.04274199 29.25 -5.40486805e-02 -1.03336052e-01 1.16617321e-01 -2.05270401 0.07227333 29.50 -4.56454216e-02 -9.46185510e-02 1.05053199e-01 -2.02027734 0.05826165 29.75 -1.15087290e-02 -1.10041855e-01 1.10642038e-01 -1.67500251 0.06703426 30.00 -5.49033321e-03 -1.19578558e-01 1.19704533e-01 -1.61667813 0.07047735 30.25 -5.47229065e-02 -1.47823618e-01 1.57627468e-01 -1.92534384 0.09469457 30.50 -3.27884325e-02 -1.20480148e-01 1.24862113e-01 -1.83650914 0.06737378 30.75 1.12659492e-02 -1.18445334e-01 1.18979909e-01 -1.47596643 0.06159631 31.00 -4.05521175e-03 -1.18648211e-01 1.18717491e-01 -1.60496148 0.06499452 31.25 -3.06696369e-02 -8.95715358e-02 9.46767483e-02 -1.90068799 0.03368005 31.50 -1.70521892e-02 -1.11498895e-01 1.12795304e-01 -1.72255637 0.05740944 31.75 -3.89822410e-02 -1.36742930e-01 1.42190872e-01 -1.84850654 0.10305816 32.00 -9.17503021e-03 -1.45417732e-01 1.45706891e-01 -1.63380710 0.10287281 32.25 1.30569025e-02 -1.59640788e-01 1.60173855e-01 -1.48918871 0.11623804 32.50 -1.95129094e-02 -1.53534251e-01 1.54769247e-01 -1.69721018 0.08834797 32.75 -4.85013354e-02 -1.59257206e-01 1.66478940e-01 -1.86641962 0.07913781 33.00 -4.20230647e-02 -1.35627195e-01 1.41988288e-01 -1.87125827 0.07186651 33.25 -6.43522249e-02 -1.41381993e-01 1.55338588e-01 -1.99793769 0.08408577 33.50 -5.16831753e-02 -1.08455324e-01 1.20140368e-01 -2.01549948 0.04717381 33.75 1.23601199e-02 -1.11581597e-01 1.12264088e-01 -1.46047407 0.04086377 34.00 -2.71215466e-02 -1.68899371e-01 1.71063076e-01 -1.73001525 0.11934468 34.25 -2.43005392e-02 -1.60457681e-01 1.62287349e-01 -1.72109933 0.10984000 34.50 -2.49237283e-02 -1.66510302e-01 1.68365296e-01 -1.71937604 0.10884947 34.75 -2.18819737e-02 -2.03073190e-01 2.04248725e-01 -1.67813629 0.14988240 35.00 -2.62055846e-02 -1.54029729e-01 1.56243048e-01 -1.73931603 0.07641226 35.25 -7.59027193e-03 -1.66410987e-01 1.66583999e-01 -1.61637634 0.08743704 35.50 4.29848396e-02 -1.72238803e-01 1.77521552e-01 -1.32622677 0.12721094 35.75 5.44077311e-02 -1.46698555e-01 1.56462990e-01 -1.21564157 0.09437529 36.00 1.63331678e-02 -1.06597077e-01 1.07841129e-01 -1.41875540 0.03879407 36.25 7.65492640e-02 -1.19199698e-01 1.41662832e-01 -0.99992861 0.06801207 36.50 2.03238168e-01 1.59554359e-03 2.03244431e-01 0.00785045 0.16426421 36.75 1.40724388e-01 4.10124406e-03 1.40784139e-01 0.02913556 0.06589997 37.00 1.03521426e-02 -1.10297729e-01 1.10782471e-01 -1.47721412 0.03720558 37.25 1.43068038e-02 -1.37953316e-01 1.38693194e-01 -1.46745817 0.06191173 37.50 5.13996772e-03 -1.08544350e-01 1.08665979e-01 -1.52347806 0.04010366 37.75 -1.79412829e-03 -1.21947821e-01 1.21961018e-01 -1.58550753 0.04996723 38.00 -3.90212737e-02 -1.80566886e-01 1.84735108e-01 -1.78362772 0.10387493 38.25 -4.79857477e-02 -1.66283785e-01 1.73069145e-01 -1.85174104 0.08159941 38.50 3.16839261e-02 -1.62651618e-01 1.65708841e-01 -1.37840934 0.07903546 38.75 2.79398902e-02 -1.69321729e-01 1.71611437e-01 -1.40725933 0.09372636 39.00 -9.44862623e-02 -1.76372601e-01 2.00087351e-01 -2.06260965 0.10477059 39.25 -6.33918566e-02 -1.68719051e-01 1.80234973e-01 -1.93020190 0.09160651 39.50 -2.40268642e-02 -1.95971092e-01 1.97438494e-01 -1.69279161 0.10938464 39.75 1.48751193e-02 -1.43731035e-01 1.44498718e-01 -1.46767072 0.06515486 40.00 8.41536820e-02 -1.61792308e-01 1.82369387e-01 -1.09117155 0.08645481 40.25 3.39530056e-02 -1.94556794e-01 1.97497222e-01 -1.39802165 0.10087947 40.50 5.59871071e-03 -2.26566180e-01 2.26635345e-01 -1.54609021 0.10704147 40.75 2.62723819e-02 -1.44549050e-01 1.46917208e-01 -1.39100486 0.05456665 41.00 1.38095255e-02 -7.90748670e-02 8.02716487e-02 -1.39790133 0.02025357 41.25 -7.18292315e-03 -9.36345972e-02 9.39097022e-02 -1.64735865 0.02873952 41.50 -5.01876384e-02 -1.23521070e-01 1.33327618e-01 -1.95672905 0.04319169 41.75 -6.17559128e-02 -1.68538159e-01 1.79496250e-01 -1.92202451 0.07554562 42.00 -9.22301545e-02 -2.03369041e-01 2.23305549e-01 -1.99656640 0.11136039 42.25 -5.34735762e-02 -1.87974265e-01 1.95432207e-01 -1.84794787 0.10347995 42.50 -6.48144421e-02 -1.63480760e-01 1.75860373e-01 -1.94825181 0.08957609 42.75 -2.15245070e-02 -1.96032213e-01 1.97210377e-01 -1.68015910 0.11172962 43.00 -7.45663309e-04 -2.17468857e-01 2.17470135e-01 -1.57422514 0.13256226 43.25 -2.63907012e-02 -2.48859839e-01 2.50255247e-01 -1.67644791 0.15546824 43.50 -4.54992387e-02 -2.80354630e-01 2.84022709e-01 -1.73168532 0.19513388 43.75 -1.47863121e-02 -2.21723541e-01 2.22216030e-01 -1.63738579 0.13708375 44.00 -4.15885371e-02 -2.19220264e-01 2.23130300e-01 -1.75827951 0.15706417 44.25 -5.31813203e-03 -1.66792843e-01 1.66877604e-01 -1.60267018 0.10636261 44.50 -6.63110628e-03 -1.46991651e-01 1.47141146e-01 -1.61587789 0.11278115 44.75 -6.65534967e-03 -1.09374489e-01 1.09576789e-01 -1.63157059 0.10284244 45.00 1.04994974e-02 -1.17654032e-01 1.18121593e-01 -1.48179166 0.11545332 45.25 3.60446275e-02 -1.87947559e-01 1.91372673e-01 -1.38131673 0.14846890 45.50 5.62716112e-02 -1.71658932e-01 1.80646846e-01 -1.25402447 0.10814757 45.75 -4.66505752e-03 -2.08490989e-01 2.08543173e-01 -1.59316794 0.15728295 46.00 -2.89840039e-02 -1.85629337e-01 1.87878480e-01 -1.72568484 0.16538096 46.25 -4.17126042e-02 -1.55222249e-01 1.60729238e-01 -1.83332245 0.15265859 46.50 -4.35350484e-02 -1.56988172e-01 1.62912819e-01 -1.84131275 0.15935862 46.75 3.24668766e-02 -1.05120823e-01 1.10020387e-01 -1.27123748 0.05262680 47.00 4.25238816e-02 -1.13491154e-01 1.21196215e-01 -1.21229838 0.04747530 47.25 -4.10432331e-02 -1.17425405e-01 1.24391611e-01 -1.90704882 0.03424572 47.50 -3.43875742e-02 -1.39820372e-01 1.43986950e-01 -1.81195120 0.04590355 47.75 1.54724935e-02 -1.23887901e-01 1.24850350e-01 -1.44654858 0.03383964 48.00 2.19006741e-03 -1.47849159e-01 1.47865378e-01 -1.55598456 0.04788672 48.25 1.01260782e-02 -1.71050181e-01 1.71349648e-01 -1.51166588 0.07910945 48.50 3.86718520e-02 -1.72659551e-01 1.76937369e-01 -1.35045534 0.07947424 48.75 2.51983592e-01 -3.41329612e-02 2.54284860e-01 -0.13463760 0.18671362 49.00 2.22534810e-01 -6.60313267e-02 2.32124703e-01 -0.28844820 0.15919503 49.25 9.39313468e-02 -1.82484129e-01 2.05240238e-01 -1.09542868 0.14188214 49.50 1.30343668e-01 -2.02415389e-01 2.40751867e-01 -0.99869196 0.21205035 49.75 2.08795267e-01 -1.95990415e-01 2.86369877e-01 -0.75377505 0.16282274 50.00 1.48021050e-01 -1.89408956e-01 2.40387155e-01 -0.90744482 0.07141093 50.25 7.76266461e-02 -1.09604197e-01 1.34309256e-01 -0.95455808 0.03473824 50.50 1.02156882e-01 -3.61765641e-02 1.08373301e-01 -0.34034716 0.03584136 50.75 7.13137793e-02 9.22760865e-02 1.16621316e-01 0.91284306 0.03857883 51.00 7.44523924e-02 2.21927064e-02 7.76896065e-02 0.28969362 0.01344580 51.25 1.23611773e-01 -9.02265459e-02 1.53038230e-01 -0.63052473 0.05178261 51.50 7.36411723e-02 -8.07896393e-02 1.09316001e-01 -0.83165427 0.02278925 51.75 1.09039117e-01 3.44404896e-02 1.14348924e-01 0.30593795 0.02275847 52.00 1.79258500e-01 -3.67520332e-02 1.82987217e-01 -0.20222023 0.05626225 52.25 3.02759544e-01 -1.46619708e-01 3.36393639e-01 -0.45099088 0.14793423 52.50 2.54072090e-01 -1.33075356e-01 2.86812966e-01 -0.48248233 0.16888389 52.75 3.14940438e-01 -4.75312199e-02 3.18506980e-01 -0.14979085 0.33669587 53.00 2.31836373e-01 4.26995090e-02 2.35735767e-01 0.18213831 0.18051860 53.25 1.70382413e-01 1.17343196e-01 2.06880623e-01 0.60310504 0.11350953 53.50 7.69431445e-02 -3.23002962e-02 8.34479276e-02 -0.39745315 0.01116673 53.75 2.96855777e-02 -1.96352784e-01 1.98584112e-01 -1.42074775 0.05653244 54.00 1.73686653e-01 -3.01756420e-01 3.48172358e-01 -1.04852206 0.17268635 54.25 3.67486899e-01 -3.99380427e-01 5.42725848e-01 -0.82696358 0.38145162 54.50 3.15930750e-01 -2.86437804e-01 4.26449123e-01 -0.73647560 0.48216337 54.75 2.95475601e-01 -1.79171655e-01 3.45555080e-01 -0.54510035 0.46202612 55.00 2.14912404e-01 -8.17806662e-02 2.29946556e-01 -0.36361025 0.22350444 55.25 2.70548967e-01 -6.28889680e-02 2.77762067e-01 -0.22839356 0.28924753 55.50 3.40823000e-01 2.81747180e-02 3.41985572e-01 0.08247918 0.26346663 55.75 3.47141993e-01 1.25676046e-01 3.69191051e-01 0.34735210 0.27404004 56.00 3.36631432e-01 2.08081225e-01 3.95750574e-01 0.55364219 0.22396841 56.25 3.77039978e-01 1.70544628e-01 4.13817128e-01 0.42478576 0.22071214 56.50 2.38274125e-01 -1.61070035e-02 2.38817911e-01 -0.06749594 0.05248886 56.75 2.72226968e-01 -3.00291876e-02 2.73878211e-01 -0.10986520 0.06503015 57.00 4.83639383e-01 -9.91219256e-02 4.93692424e-01 -0.20215068 0.23144766 57.25 4.22387129e-01 -1.10305029e-01 4.36552501e-01 -0.25544190 0.21065441 57.50 2.01477888e-01 -9.23879662e-02 2.21650345e-01 -0.42994247 0.06299003 57.75 1.71330143e-01 -2.72031502e-02 1.73476307e-01 -0.15746179 0.03686360 58.00 3.79041171e-01 6.46118254e-02 3.84508644e-01 0.16883840 0.14768918 58.25 5.97409248e-01 2.18299845e-01 6.36044521e-01 0.35033739 0.28035152 58.50 7.74638262e-01 4.61299917e-01 9.01588626e-01 0.53710681 0.51494349 58.75 9.25277503e-01 4.45881796e-01 1.02710712e+00 0.44905477 0.53507861 59.00 1.22053188e+00 5.20596827e-01 1.32692092e+00 0.40316819 0.54567562 59.25 1.24639661e+00 1.53345631e-01 1.25579433e+00 0.12241598 0.38231432 59.50 1.38146667e+00 -6.90519998e-01 1.54443129e+00 -0.46352406 0.33883622 59.75 5.07678521e-01 -6.14750368e-01 7.97280061e-01 -0.88050337 0.11285146 60.00 -4.34442366e-01 -4.16424110e-01 6.01788342e-01 -2.37736769 0.14359006 60.25 -5.13333933e-01 -1.97419615e-01 5.49987483e-01 -2.77444684 0.14984971 60.50 -4.06305548e-01 2.22818053e-02 4.06916056e-01 3.08680751 0.07653613 60.75 -1.02519748e-01 -7.60785720e-02 1.27664591e-01 -2.50317513 0.01001414 61.00 3.70336686e-01 -2.26909886e-02 3.71031187e-01 -0.06119474 0.06565209 61.25 3.07483873e-01 -1.34905510e-01 3.35776457e-01 -0.41345085 0.03770053 61.50 2.76190209e-01 -3.77935775e-01 4.68098795e-01 -0.93970595 0.07263545 61.75 2.00779845e-01 -3.33332585e-01 3.89131287e-01 -1.02865736 0.07832864 62.00 1.22624720e-01 -4.58137121e-01 4.74264108e-01 -1.30926731 0.13429170 62.25 1.31138275e-01 -4.10848952e-01 4.31270342e-01 -1.26182965 0.13462738 62.50 2.53930332e-01 -5.84221592e-01 6.37020786e-01 -1.16078280 0.24859357 62.75 1.31805661e-01 -5.86866344e-01 6.01485526e-01 -1.34986997 0.24324695 63.00 -1.19764364e-01 -6.51540679e-01 6.62456610e-01 -1.75258417 0.28588653 63.25 -2.62514933e-01 -4.86655978e-01 5.52944962e-01 -2.06548515 0.30416615 63.50 -4.43191753e-01 -3.42350612e-01 5.60020421e-01 -2.48386759 0.39502521 63.75 -2.62781247e-01 -7.48165890e-02 2.73224278e-01 -2.86422124 0.13539432 64.00 -2.16016475e-01 1.12638604e-01 2.43619729e-01 2.66094427 0.14833650 64.25 -2.67357722e-02 1.56222091e-01 1.58493354e-01 1.74029378 0.05163307 64.50 2.69233848e-02 2.62660617e-01 2.64036870e-01 1.46865051 0.12420573 64.75 1.16008088e-01 2.23635924e-01 2.51934322e-01 1.09227222 0.08291534 65.00 1.99850489e-01 2.49031631e-01 3.19307017e-01 0.89452649 0.12626040 65.25 2.13697926e-01 3.84344473e-02 2.17126715e-01 0.17795161 0.04522273 65.50 3.05690883e-01 2.01869377e-01 3.66330672e-01 0.58363135 0.10918234 65.75 4.89056343e-01 2.09334279e-01 5.31974573e-01 0.40444032 0.19163667 66.00 6.17386224e-01 2.99892240e-01 6.86368054e-01 0.45217867 0.26886295 66.25 7.23409642e-01 1.56365886e-01 7.40116072e-01 0.21287627 0.24849661 66.50 8.30064783e-01 2.27040840e-01 8.60555104e-01 0.26699145 0.32592197 66.75 9.33510506e-01 2.53723556e-01 9.67376611e-01 0.26538418 0.29214263 67.00 1.05617311e+00 6.31934291e-03 1.05619202e+00 0.00598317 0.29174525 67.25 1.01083126e+00 -4.41834246e-01 1.10317602e+00 -0.41207457 0.31718509 67.50 1.14625309e+00 -3.81339280e-01 1.20802144e+00 -0.32116542 0.39063024 67.75 1.39121568e+00 -3.39109980e-01 1.43194854e+00 -0.23908850 0.55477761 68.00 1.63559329e+00 -4.20248280e-01 1.68871964e+00 -0.25149908 0.60598989 68.25 2.59216839e+00 -5.48117202e-01 2.64948475e+00 -0.20838172 0.68818587 68.50 3.31558803e+00 -9.80670015e-01 3.45757685e+00 -0.28757670 0.66382201 68.75 1.91262971e+00 -2.56846120e+00 3.20236559e+00 -0.93072174 0.39582435 69.00 -4.39977627e-01 -1.50106379e+00 1.56421636e+00 -1.85592060 0.17945810 69.25 -1.29968179e+00 -5.94967110e-01 1.42939100e+00 -2.71228852 0.57793226 69.50 -9.88503111e-01 -4.47927970e-01 1.08525475e+00 -2.71613253 0.60850808 69.75 -5.20517264e-01 -1.81286580e-01 5.51183315e-01 -2.80644953 0.52407971 70.00 -4.43788125e-01 -1.32964451e-01 4.63279014e-01 -2.85049144 0.55133123 70.25 -3.68718180e-01 -3.93712524e-02 3.70814228e-01 -3.03521701 0.60726759 70.50 -3.08856389e-01 3.55959740e-02 3.10900856e-01 3.02684802 0.60857824 70.75 -2.58324315e-01 6.36584328e-02 2.66052340e-01 2.89997837 0.65524597 71.00 -2.42373847e-01 1.16137072e-01 2.68761793e-01 2.69475151 0.57400627 71.25 -2.26900298e-01 2.97352461e-01 3.74035067e-01 2.22260895 0.70281859 71.50 -1.41883057e-01 3.73459921e-01 3.99503585e-01 1.93386913 0.59168191 71.75 9.70221501e-02 4.41268045e-01 4.51808350e-01 1.35436885 0.52474271 72.00 3.31670255e-01 3.15690734e-01 4.57892780e-01 0.76071908 0.46363578 72.25 4.53299697e-01 1.15590931e-01 4.67805385e-01 0.24967796 0.52795714 72.50 4.13387537e-01 -3.62882094e-02 4.14977217e-01 -0.08755810 0.58884183 72.75 3.71572498e-01 -8.92483778e-02 3.82140543e-01 -0.23572559 0.73682902 73.00 3.03292383e-01 -9.21870119e-02 3.16993241e-01 -0.29508060 0.66978811 73.25 2.57707104e-01 -7.65713158e-02 2.68842180e-01 -0.28881743 0.70321693 73.50 2.44665159e-01 -5.40430896e-02 2.50562757e-01 -0.21739517 0.72802260 73.75 2.41505212e-01 -4.35338790e-02 2.45397568e-01 -0.17834537 0.80403592 74.00 2.23997544e-01 -4.58425525e-02 2.28640414e-01 -0.20186892 0.73004232 74.25 2.12534313e-01 -2.67201890e-02 2.14207382e-01 -0.12506559 0.76319921 74.50 2.04599362e-01 -8.34206921e-03 2.04769356e-01 -0.04075013 0.72595931 74.75 1.90931227e-01 -7.75805916e-04 1.90932803e-01 -0.00406325 0.73219174 75.00 1.94731470e-01 4.11465786e-02 1.99031119e-01 0.20823607 0.59075534 75.25 2.15744575e-01 1.01033193e-01 2.38229779e-01 0.43796759 0.60206018 75.50 3.42267555e-01 9.46179457e-02 3.55105104e-01 0.26970855 0.65934609 75.75 3.96624775e-01 6.02760014e-02 4.01178774e-01 0.15081834 0.75064575 76.00 3.71205818e-01 -7.33131919e-02 3.78376246e-01 -0.19499067 0.60991348 76.25 3.43507559e-01 -7.88349566e-02 3.52437787e-01 -0.22559338 0.58860225 76.50 3.59129000e-01 -5.91305970e-02 3.63964375e-01 -0.16318590 0.50046289 76.75 4.07010147e-01 -1.42424942e-01 4.31210069e-01 -0.33661220 0.53928406 77.00 1.75838047e-01 -9.99077328e-02 2.02238903e-01 -0.51669407 0.19097634 77.25 1.91145455e-01 -3.47846398e-02 1.94284729e-01 -0.18001008 0.35450998 77.50 2.82955665e-01 -6.17540077e-02 2.89616067e-01 -0.21487689 0.66828762 77.75 3.07534025e-01 -1.14171725e-01 3.28043228e-01 -0.35547815 0.68772547 78.00 3.70696944e-01 -2.63783725e-01 4.54970415e-01 -0.61846129 0.71149941 78.25 3.43892448e-01 -3.96930164e-01 5.25181465e-01 -0.85686922 0.75256675 78.50 1.32184892e-01 -4.41476758e-01 4.60841159e-01 -1.27987605 0.76457632 78.75 6.69327601e-02 -3.91260277e-01 3.96944075e-01 -1.40136674 0.72895492 79.00 -9.29070556e-02 -3.23088700e-01 3.36181542e-01 -1.85080062 0.75540417 79.25 -9.79059358e-02 -2.92269709e-01 3.08232307e-01 -1.89403254 0.75910552 79.50 -1.21042059e-01 -2.79771339e-01 3.04833040e-01 -1.97912567 0.82320706 79.75 -1.64848967e-01 -2.82832586e-01 3.27367460e-01 -2.09851006 0.81288020 80.00 -2.57501978e-01 -1.94599397e-01 3.22763372e-01 -2.49444078 0.79177630 80.25 -2.72330284e-01 -1.39764845e-01 3.06101283e-01 -2.66742653 0.66772844 80.50 -2.72391381e-01 -1.15753881e-01 2.95966257e-01 -2.73976074 0.58519333 80.75 -2.97538295e-01 -1.20483993e-01 3.21006900e-01 -2.75683828 0.63276196 81.00 -3.18847033e-01 -1.74417914e-02 3.19323733e-01 -3.08694443 0.78438612 81.25 -2.84876082e-01 3.65353447e-02 2.87209355e-01 3.01403899 0.69788338 81.50 -2.54126486e-01 8.68649900e-02 2.68562465e-01 2.81222550 0.66120821 81.75 -2.48633174e-01 1.02653344e-01 2.68991012e-01 2.75004035 0.55741985 82.00 -2.62410826e-01 1.53486932e-01 3.04002763e-01 2.61234203 0.61417379 82.25 -2.06851791e-01 1.34391914e-01 2.46675597e-01 2.56542732 0.46639850 82.50 -1.88574217e-01 1.25400510e-01 2.26463072e-01 2.55474973 0.49162836 82.75 -1.65229093e-01 1.28388907e-01 2.09247137e-01 2.48101201 0.41152018 83.00 -1.70387799e-01 1.20022975e-01 2.08416690e-01 2.52791267 0.50973890 83.25 -1.52406506e-01 1.19984961e-01 1.93969415e-01 2.47466269 0.34422317 83.50 -1.31944495e-01 1.25759670e-01 1.82276835e-01 2.38018959 0.29256724 83.75 -1.53310594e-01 9.12204561e-02 1.78396497e-01 2.60485459 0.19620752 84.00 -1.53644352e-01 9.66037808e-02 1.81490709e-01 2.58030174 0.22431989 84.25 -1.50471343e-01 9.43183329e-02 1.77588212e-01 2.58168619 0.17419369 84.50 -1.56993025e-01 1.30256910e-01 2.03994295e-01 2.44900324 0.25945515 84.75 -1.41678815e-01 8.63343493e-02 1.65911140e-01 2.59431434 0.18833873 85.00 -1.63670222e-01 4.85949603e-02 1.70731988e-01 2.85297518 0.24305727 85.25 -1.91047927e-01 8.80464034e-02 2.10360357e-01 2.70974410 0.22498575 85.50 -2.01910006e-01 1.49170084e-01 2.51036580e-01 2.50530146 0.34992021 85.75 -1.55024653e-01 1.14044960e-01 1.92454919e-01 2.50733448 0.18679190 86.00 -1.68651925e-01 8.56949376e-02 1.89174771e-01 2.67147242 0.17378221 86.25 -9.86145619e-02 1.08611435e-01 1.46701314e-01 2.30799046 0.10220397 86.50 -7.14879357e-02 1.37864512e-01 1.55296969e-01 2.04916381 0.11257350 86.75 -7.92663733e-02 9.86768922e-02 1.26571272e-01 2.24754146 0.06648893 87.00 -3.99799748e-02 9.78792980e-02 1.05729633e-01 1.95857619 0.04162345 87.25 1.80171992e-02 1.30768738e-01 1.32004100e-01 1.43387925 0.03985513 87.50 4.43429565e-02 9.78413102e-02 1.07420760e-01 1.14527366 0.02992372 87.75 -5.29185193e-02 -4.28983536e-02 6.81222315e-02 -2.46039196 0.02413010 88.00 -6.47100294e-02 -2.97019975e-02 7.12010994e-02 -2.71127838 0.03178184 88.25 -8.79173790e-02 -5.46757792e-02 1.03532151e-01 -2.58522598 0.04609480 88.50 -8.68519157e-02 -4.62041613e-02 9.83772320e-02 -2.65268346 0.03434450 88.75 -5.01058905e-02 -1.88636404e-01 1.95177593e-01 -1.83042272 0.12248935 89.00 -1.00382754e-01 -2.36739630e-01 2.57142665e-01 -1.97183810 0.15543912 89.25 -2.22452367e-01 -3.03823355e-01 3.76555024e-01 -2.20279257 0.21318326 89.50 -1.70997771e-01 -2.87739777e-01 3.34715427e-01 -2.10699875 0.15289123 89.75 -2.57242376e-01 -2.76404129e-01 3.77588245e-01 -2.32030271 0.09086506 90.00 -2.94994685e-01 -5.68644091e-02 3.00425407e-01 -2.95116419 0.06223753 90.25 -2.46528032e-01 2.76455579e-01 3.70410256e-01 2.29903219 0.28876017 90.50 -2.70684687e-01 1.80499344e-01 3.25346297e-01 2.55348037 0.35755579 90.75 -2.76626128e-01 2.66157914e-02 2.77903608e-01 3.04567217 0.44146812 91.00 -3.53332213e-01 -2.28054902e-02 3.54067427e-01 -3.07713801 0.45623765 91.25 -4.86399422e-01 6.46587845e-02 4.90678261e-01 3.00943398 0.59225605 91.50 -3.98154406e-01 1.53983386e-01 4.26893212e-01 2.77256680 0.49446229 91.75 -3.22837835e-01 2.17331717e-01 3.89175209e-01 2.54908639 0.75093973 92.00 -3.00391307e-01 1.75229273e-01 3.47764626e-01 2.61351570 0.75675843 92.25 -3.50811477e-01 1.21005284e-01 3.71094289e-01 2.80944196 0.83178418 92.50 -3.75830416e-01 9.58694798e-02 3.87865259e-01 2.89183192 0.68573483 92.75 -4.08180125e-01 1.12272074e-01 4.23339146e-01 2.87317511 0.64534801 93.00 -3.88586358e-01 1.25770530e-01 4.08433084e-01 2.82857166 0.58416038 93.25 -3.10154530e-01 1.91877796e-01 3.64709365e-01 2.58757104 0.53200298 93.50 -2.90935121e-01 1.64773401e-01 3.34355377e-01 2.62627740 0.39389493 93.75 -3.15473132e-01 1.44058284e-01 3.46808429e-01 2.71322898 0.53742000 94.00 -3.48048222e-01 1.00091529e-01 3.62154496e-01 2.86156941 0.56350136 94.25 -3.95022844e-01 8.63385974e-02 4.04348119e-01 2.92641047 0.72894160 94.50 -4.38830132e-01 1.13983275e-01 4.53391742e-01 2.88746487 0.64619066 94.75 -4.54185026e-01 1.78097462e-01 4.87855249e-01 2.76789315 0.66413826 95.00 -4.36889184e-01 2.28987583e-01 4.93262072e-01 2.65882638 0.58203529 95.25 -3.81130446e-01 3.28583685e-01 5.03217304e-01 2.43009898 0.58592461 95.50 -2.05900024e-01 3.18006432e-01 3.78844177e-01 2.14539182 0.42641835 95.75 -1.28969850e-01 2.70223104e-01 2.99422358e-01 2.01609656 0.45532710 96.00 -3.25511322e-02 1.06923852e-01 1.11768897e-01 1.86631497 0.08817075 96.25 -5.79542372e-02 -3.05735552e-03 5.80348260e-02 -3.08888686 0.02688345 96.50 -2.00876720e-01 2.45504074e-02 2.02371389e-01 3.01997948 0.19763993 96.75 -2.25108588e-01 9.22888676e-02 2.43292235e-01 2.75251692 0.27824916 97.00 -7.86072893e-02 1.34987745e-01 1.56207546e-01 2.09812116 0.09672672 97.25 4.30326760e-02 8.86423404e-02 9.85356571e-02 1.11884490 0.04468297 97.50 1.85340290e-01 -1.96019196e-02 1.86373975e-01 -0.10537007 0.16162209 97.75 2.67392675e-01 -1.36425946e-01 3.00184745e-01 -0.47178081 0.27124579 98.00 5.90487033e-01 -4.93176111e-01 7.69348824e-01 -0.69584024 0.49696030 98.25 5.85022174e-01 -9.73995926e-01 1.13618617e+00 -1.02990542 0.53236780 98.50 -6.47367320e-01 -1.91512605e+00 2.02158162e+00 -1.89676662 0.60194508 98.75 -1.63070315e+00 -1.57248434e+00 2.26536968e+00 -2.37436777 0.66900594 99.00 -1.98096398e+00 -8.01138273e-02 1.98258329e+00 -3.10117284 0.78697190 99.25 -1.67261787e+00 1.63577131e-01 1.68059752e+00 3.04410559 0.83895033 99.50 -1.01977408e+00 1.29224596e-01 1.02792907e+00 3.01554562 0.79706849 99.75 -9.54737835e-01 1.29815830e-01 9.63522954e-01 3.00645128 0.80474735 100.00 -9.73809153e-01 7.09279838e-02 9.76388778e-01 3.06888543 0.79855694 100.25 -1.00407863e+00 1.71009836e-01 1.01853732e+00 2.97289618 0.79049099 100.50 -9.66583490e-01 4.24824665e-01 1.05582178e+00 2.72749503 0.75153615 100.75 -7.67367682e-01 4.83390807e-01 9.06928791e-01 2.57945333 0.72447411 101.00 -6.16122255e-01 4.11303303e-01 7.40794870e-01 2.55296653 0.80331380 101.25 -5.63637365e-01 3.39013508e-01 6.57736450e-01 2.60008966 0.76901718 101.50 -5.36977657e-01 3.11088534e-01 6.20581244e-01 2.61650858 0.81401629 101.75 -5.59888544e-01 2.84383355e-01 6.27972192e-01 2.67162237 0.81013317 102.00 -5.47150941e-01 2.81570254e-01 6.15350274e-01 2.66632416 0.85697393 102.25 -5.64544565e-01 2.93366580e-01 6.36218921e-01 2.66234751 0.84534811 102.50 -5.34634161e-01 3.28163024e-01 6.27315436e-01 2.59108162 0.88989233 102.75 -4.79203461e-01 3.06138070e-01 5.68644419e-01 2.57309730 0.85960847 103.00 -4.79430844e-01 2.84125626e-01 5.57298220e-01 2.60660908 0.91269747 103.25 -4.74155563e-01 2.69330548e-01 5.45309492e-01 2.62501873 0.87299147 103.50 -4.71126683e-01 2.60687223e-01 5.38440507e-01 2.63619854 0.92267026 103.75 -4.56996200e-01 2.52388426e-01 5.22058851e-01 2.63700305 0.93462283 104.00 -4.57271866e-01 2.69873248e-01 5.30969990e-01 2.60842416 0.94841034 104.25 -4.35074384e-01 3.45725319e-01 5.55711900e-01 2.47013165 0.90024567 104.50 -3.47496540e-01 4.08280689e-01 5.36140808e-01 2.27594122 0.87827179 104.75 -2.23367826e-01 4.16296435e-01 4.72436141e-01 2.06326204 0.76686625 105.00 -1.31112007e-01 4.00793652e-01 4.21694095e-01 1.88695438 0.77832245 105.25 -3.24832095e-02 3.74173879e-01 3.75581217e-01 1.65739236 0.61211123 105.50 1.17997615e-01 3.41918832e-01 3.61706960e-01 1.23848969 0.64196719 105.75 2.70965713e-01 2.70805039e-01 3.83089790e-01 0.78510159 0.57915888 106.00 3.94668388e-01 2.46132730e-01 4.65128430e-01 0.55762391 0.72495648 106.25 6.62553934e-01 9.53886866e-02 6.69385327e-01 0.14298866 0.76754394 106.50 8.51737120e-01 -4.85076390e-02 8.53117292e-01 -0.05688997 0.85567007 106.75 9.19554883e-01 -4.54208257e-01 1.02561510e+00 -0.45879077 0.84182126 107.00 8.67205196e-01 -7.62952739e-01 1.15505053e+00 -0.72153277 0.87796323 107.25 8.31823765e-01 -9.68840224e-01 1.27694250e+00 -0.86134400 0.84711118 107.50 8.41339205e-01 -1.12586556e+00 1.40549810e+00 -0.92903693 0.87937664 107.75 8.73619732e-01 -1.57225172e+00 1.79866253e+00 -1.06362660 0.87371195 108.00 7.93425267e-01 -1.82391382e+00 1.98901616e+00 -1.16047568 0.88065300 108.25 2.01153150e-01 -2.54083453e+00 2.54878456e+00 -1.49179296 0.87754475 108.50 -1.55970482e-01 -2.81223710e+00 2.81655895e+00 -1.62620092 0.91441353 108.75 -9.85180090e-01 -2.77330511e+00 2.94309378e+00 -1.91212883 0.92437522 109.00 -1.24490058e+00 -2.67618889e+00 2.95156982e+00 -2.00619923 0.94381528 109.25 -1.64104201e+00 -2.56206626e+00 3.04256510e+00 -2.14047482 0.93625833 109.50 -2.04068110e+00 -2.30158237e+00 3.07598127e+00 -2.29618247 0.93554077 109.75 -2.29534601e+00 -1.68159194e+00 2.84541118e+00 -2.50931478 0.95232631 110.00 -2.35073002e+00 -1.48489850e+00 2.78044155e+00 -2.57820739 0.92597129 110.25 -2.66711519e+00 -1.62131416e+00 3.12124384e+00 -2.59539146 0.92353597 110.50 -2.78903782e+00 -1.40244338e+00 3.12179106e+00 -2.67567459 0.95551294 110.75 -2.62771325e+00 -8.96394688e-01 2.77640061e+00 -2.81284061 0.97293381 111.00 -2.56589103e+00 -7.47974591e-01 2.67268830e+00 -2.85794592 0.96524978 111.25 -2.46041246e+00 -5.81443142e-01 2.52818227e+00 -2.90953073 0.96709079 111.50 -2.36419324e+00 -5.04163675e-01 2.41735200e+00 -2.93148999 0.95051455 111.75 -2.33539106e+00 -4.30923961e-01 2.37481512e+00 -2.95912604 0.95228320 112.00 -2.35379305e+00 -3.90815359e-01 2.38601726e+00 -2.97705726 0.93122711 112.25 -2.42904097e+00 -2.84051782e-01 2.44559307e+00 -3.02518148 0.93568465 112.50 -2.46570100e+00 -1.87171974e-01 2.47279493e+00 -3.06582771 0.91363531 112.75 -2.59221495e+00 7.61532519e-02 2.59333331e+00 3.11222342 0.91877216 113.00 -2.66305717e+00 3.37039603e-01 2.68430050e+00 3.01570081 0.89151167 113.25 -2.72675239e+00 7.91036407e-01 2.83917544e+00 2.85924112 0.92554412 113.50 -2.50641036e+00 1.02492991e+00 2.70787264e+00 2.75341742 0.87808833 113.75 -2.08957274e+00 1.30686072e+00 2.46458905e+00 2.58269132 0.87868381 114.00 -1.77780782e+00 1.18999252e+00 2.13931832e+00 2.55172811 0.83008499 114.25 -1.77210389e+00 9.64884527e-01 2.01775973e+00 2.64299323 0.87716228 114.50 -1.84361344e+00 9.58611315e-01 2.07794277e+00 2.66210226 0.84726936 114.75 -1.94896237e+00 9.87890442e-01 2.18503589e+00 2.67245604 0.87407472 115.00 -2.08118108e+00 1.16516209e+00 2.38514515e+00 2.63121382 0.85373145 115.25 -2.16026086e+00 1.32298181e+00 2.53318137e+00 2.59209255 0.88851985 115.50 -2.16478644e+00 1.39367954e+00 2.57461512e+00 2.56959157 0.79496817 115.75 -2.68520543e+00 1.87561655e+00 3.27540312e+00 2.53187397 0.86925806 116.00 -3.00564385e+00 2.59320699e+00 3.96971251e+00 2.42972623 0.81448846 116.25 -2.93815428e+00 3.62182194e+00 4.66372649e+00 2.25235136 0.81119219 116.50 -1.71937065e+00 4.90105617e+00 5.19389902e+00 1.90819822 0.80150709 116.75 -4.28068489e-01 5.22702678e+00 5.24452587e+00 1.65250919 0.73261573 117.00 1.16426183e+00 7.42202068e-01 1.38071341e+00 0.56752856 0.12830203 117.25 -9.40054659e-02 -2.21943231e-01 2.41030756e-01 -1.97144356 0.00911798 117.50 -1.79415229e+00 1.41017874e+00 2.28201370e+00 2.47545538 0.67801382 117.75 -2.16435346e+00 2.04348869e+00 2.97662089e+00 2.38491029 0.88403088 118.00 -2.88220048e+00 3.17436419e+00 4.28761794e+00 2.30799268 0.79929311 118.25 -3.74552372e+00 4.37395589e+00 5.75851005e+00 2.27895040 0.82532275 118.50 -2.03388894e+00 6.58536341e+00 6.89229392e+00 1.87035241 0.61067514 118.75 5.03284433e-01 7.79829194e+00 7.81451549e+00 1.50634793 0.56717929 119.00 1.66721706e+00 3.35817639e+00 3.74926145e+00 1.10998071 0.23454172 119.25 6.23766174e-01 1.91966428e+00 2.01846357e+00 1.25662319 0.12319610 119.50 1.01414855e+00 4.47655849e+00 4.58999708e+00 1.34801042 0.46916401 119.75 1.71456683e+00 5.15517126e+00 5.43281972e+00 1.24971345 0.64519378 120.00 1.64322043e+00 5.97519875e+00 6.19702941e+00 1.30242377 0.79296641 120.25 1.84413159e+00 5.90334715e+00 6.18468502e+00 1.26801399 0.80396449 120.50 2.58693527e+00 5.97951659e+00 6.51512492e+00 1.16247840 0.82105354 120.75 2.70741598e+00 6.12139725e+00 6.69340015e+00 1.15437480 0.80612904 121.00 2.96199721e+00 6.37637169e+00 7.03075695e+00 1.13592758 0.81194188 121.25 3.09367224e+00 6.98310258e+00 7.63770447e+00 1.15375994 0.81262039 121.50 3.14887816e+00 8.87105774e+00 9.41334686e+00 1.22970890 0.84202720 121.75 4.64407354e+00 8.96232222e+00 1.00940893e+01 1.09271271 0.78793235 122.00 7.24963901e+00 9.76522742e+00 1.21621105e+01 0.93218133 0.86219691 122.25 8.18291531e+00 9.06597004e+00 1.22127767e+01 0.83654839 0.85537049 122.50 9.16074614e+00 9.09566337e+00 1.29093130e+01 0.78183325 0.88821117 122.75 1.09312926e+01 1.06812524e+01 1.52833999e+01 0.77382946 0.84749845 123.00 1.66680992e+01 1.16320543e+01 2.03256049e+01 0.60929048 0.84976691 123.25 2.01280742e+01 4.35381919e+00 2.05935697e+01 0.21302393 0.65635398 123.50 1.83276047e+01 -1.04442403e+01 2.10946261e+01 -0.51796580 0.68501804 123.75 9.63229535e+00 -8.98835494e+00 1.31746589e+01 -0.75082988 0.56134646 124.00 5.22095807e+00 -5.33401147e+00 7.46391864e+00 -0.79610867 0.61315367 124.25 5.27259474e+00 -3.62502778e+00 6.39852184e+00 -0.60230266 0.68462750 124.50 5.93897661e+00 -2.18283870e+00 6.32741874e+00 -0.35221845 0.77667573 124.75 7.37052801e+00 -2.55492747e+00 7.80079082e+00 -0.33367930 0.78133802 125.00 7.06601149e+00 -4.97435375e+00 8.64133749e+00 -0.61339429 0.83841946 125.25 4.90924567e+00 -5.58572495e+00 7.43646531e+00 -0.84976659 0.84052496 125.50 3.44479703e+00 -5.78397621e+00 6.73208789e+00 -1.03363617 0.86746092 125.75 2.44319242e+00 -5.17979809e+00 5.72708455e+00 -1.13006262 0.86165090 126.00 2.02853859e+00 -5.05284304e+00 5.44483164e+00 -1.18902783 0.90133391 126.25 1.32278731e+00 -4.27191506e+00 4.47202689e+00 -1.27051239 0.84195742 126.50 6.87051759e-01 -3.89238867e+00 3.95255989e+00 -1.39608435 0.87235008 126.75 -9.63817963e-02 -2.87434666e+00 2.87596213e+00 -1.60431549 0.73514164 127.00 -1.10862941e-01 -2.07040344e+00 2.07336947e+00 -1.62429178 0.65032501 127.25 9.92090771e-01 -1.70358547e+00 1.97140750e+00 -1.04345246 0.58728918 127.50 1.27864753e+00 -1.99964168e+00 2.37350086e+00 -1.00188170 0.71980378 127.75 6.12846450e-01 -2.38433242e+00 2.46183303e+00 -1.31921163 0.78441474 128.00 2.27237355e-01 -2.42208766e+00 2.43272388e+00 -1.47725135 0.84095100 128.25 -3.55359509e-01 -1.98503358e+00 2.01659086e+00 -1.74793927 0.81631908 128.50 -5.67966724e-01 -1.83028216e+00 1.91638175e+00 -1.87169071 0.85804846 128.75 -1.02466765e+00 -1.46981958e+00 1.79173475e+00 -2.17959916 0.82077129 129.00 -1.14348429e+00 -1.11187896e+00 1.59493923e+00 -2.37020698 0.81550771 129.25 -9.99536680e-01 -6.65072312e-01 1.20058101e+00 -2.55448093 0.80796797 129.50 -1.08337118e+00 -6.02410292e-01 1.23959319e+00 -2.63411517 0.84231881 129.75 -1.29362751e+00 -3.29420071e-01 1.33491188e+00 -2.89224391 0.85094216 130.00 -1.37147948e+00 -1.28470851e-01 1.37748347e+00 -3.04819202 0.87042304 130.25 -1.26828763e+00 2.56584416e-01 1.29398187e+00 2.94197909 0.87781081 130.50 -1.15923203e+00 4.24336534e-01 1.23445551e+00 2.79069182 0.87082357 130.75 -1.01631976e+00 6.28819753e-01 1.19512348e+00 2.58752034 0.93050389 131.00 -9.68886686e-01 6.53095604e-01 1.16844995e+00 2.54848347 0.94015664 131.25 -8.86342821e-01 5.71600236e-01 1.05467077e+00 2.56881282 0.90998187 131.50 -9.27561501e-01 4.92005234e-01 1.04997118e+00 2.65389945 0.89020307 131.75 -1.14448630e+00 5.91862029e-01 1.28846791e+00 2.66432561 0.94814419 132.00 -1.24904063e+00 6.93349184e-01 1.42857817e+00 2.63483821 0.95794789 132.25 -1.29355457e+00 8.28060497e-01 1.53589310e+00 2.57217770 0.96949103 132.50 -1.29326832e+00 8.84457141e-01 1.56678249e+00 2.54175876 0.96865557 132.75 -1.31403789e+00 8.19870615e-01 1.54883292e+00 2.58376153 0.97088779 133.00 -1.42619451e+00 8.06429059e-01 1.63840123e+00 2.62697178 0.96506187 133.25 -1.58253122e+00 8.59627296e-01 1.80093424e+00 2.64398695 0.97400859 133.50 -1.74260920e+00 9.11015235e-01 1.96637625e+00 2.65988126 0.95507846 133.75 -2.08130608e+00 7.99993000e-01 2.22975868e+00 2.77463202 0.95831164 134.00 -2.34623189e+00 1.04947707e+00 2.57025411e+00 2.72098364 0.89002154 134.25 -2.32640106e+00 1.99422559e+00 3.06416018e+00 2.43292487 0.86152551 134.50 -1.98273239e+00 2.10980116e+00 2.89525278e+00 2.32515554 0.95171963 134.75 -2.00774162e+00 1.92513012e+00 2.78157372e+00 2.37719679 0.99142963 135.00 -2.16926873e+00 1.93861918e+00 2.90929048e+00 2.41228356 0.99212448 135.25 -2.29077485e+00 2.04675126e+00 3.07194403e+00 2.41239395 0.99452325 135.50 -2.32408539e+00 2.17012787e+00 3.17975280e+00 2.39043794 0.99220809 135.75 -2.31404249e+00 2.35628782e+00 3.30255733e+00 2.34714927 0.99045692 136.00 -2.18270982e+00 2.39303235e+00 3.23895445e+00 2.31026214 0.98242501 136.25 -1.99452367e+00 2.38079300e+00 3.10584932e+00 2.26813904 0.97846607 136.50 -1.87197710e+00 2.10996183e+00 2.82068027e+00 2.29649946 0.94922225 136.75 -1.93780125e+00 1.61820710e+00 2.52461242e+00 2.44582808 0.91564976 137.00 -2.23841792e+00 6.85262744e-01 2.34096131e+00 2.84451506 0.73996648 137.25 -2.96323247e+00 -3.43633274e-01 2.98309077e+00 -3.02614265 0.77889844 137.50 -4.63478390e+00 -5.66530385e-01 4.66928030e+00 -3.01996156 0.72027803 137.75 -7.09531571e+00 -5.38476853e-02 7.09552004e+00 -3.13400361 0.78429909 138.00 -7.31311172e+00 2.53255545e+00 7.73921444e+00 2.80821481 0.59084439 138.25 -5.64669681e+00 5.75196219e+00 8.06041276e+00 2.34695986 0.44685400 138.50 -1.37137773e+00 7.62024914e+00 7.74266581e+00 1.74885531 0.54656963 138.75 -9.26190811e-01 8.52588755e+00 8.57604734e+00 1.67900477 0.75287434 139.00 -7.21606915e-01 8.56357052e+00 8.59391975e+00 1.65486246 0.80273535 139.25 -1.78634953e-01 8.36018618e+00 8.36209444e+00 1.59216042 0.83303864 139.50 -2.92610725e-02 7.23390711e+00 7.23396629e+00 1.57484129 0.87352243 139.75 3.18773843e-03 6.97352001e+00 6.97352074e+00 1.57033921 0.91023761 140.00 -2.48246452e-01 6.53283332e+00 6.53754828e+00 1.60877787 0.88359239 140.25 -5.02784683e-01 6.76279619e+00 6.78146037e+00 1.64500548 0.91059111 140.50 -9.77893161e-01 7.02970376e+00 7.09739459e+00 1.70901802 0.91438918 140.75 -1.10819083e+00 7.10771208e+00 7.19358450e+00 1.72546492 0.88353441 141.00 -1.59162577e+00 7.74401281e+00 7.90588433e+00 1.77350335 0.89965730 141.25 -1.81346251e+00 8.34104967e+00 8.53590978e+00 1.78487886 0.89705793 141.50 -1.95937113e+00 9.86112436e+00 1.00539002e+01 1.76693823 0.88665618 141.75 -2.13045196e+00 1.10016161e+01 1.12059976e+01 1.76207776 0.87640817 142.00 5.86944690e-02 1.31164073e+01 1.31165386e+01 1.56632147 0.81087105 142.25 2.38611065e+00 1.24165036e+01 1.26436975e+01 1.38093841 0.79462678 142.50 4.39974566e+00 1.05903670e+01 1.14679394e+01 1.17704414 0.84446195 142.75 4.82238671e+00 9.53613384e+00 1.06861248e+01 1.10260214 0.82668382 143.00 5.30151667e+00 8.85589599e+00 1.03214811e+01 1.03137551 0.85513987 143.25 5.02106873e+00 7.98670491e+00 9.43390621e+00 1.00955625 0.83626006 143.50 5.70231230e+00 7.33800261e+00 9.29315059e+00 0.91017981 0.87078228 143.75 5.27180483e+00 7.09686714e+00 8.84067019e+00 0.93189629 0.84045632 144.00 5.18445568e+00 6.69573129e+00 8.46825828e+00 0.91192832 0.82749004 144.25 5.11277359e+00 6.31888235e+00 8.12826721e+00 0.89051532 0.79979423 144.50 4.95922247e+00 6.17307069e+00 7.91837668e+00 0.89400756 0.82981763 144.75 4.50311194e+00 6.03618480e+00 7.53083953e+00 0.92984757 0.78999517 145.00 5.19113897e+00 5.67255250e+00 7.68932869e+00 0.82968318 0.79309081 145.25 5.78646148e+00 5.84727286e+00 8.22640482e+00 0.79062527 0.78348249 145.50 6.62547758e+00 6.68441440e+00 9.41160714e+00 0.78982618 0.78473747 145.75 6.13438003e+00 6.38565609e+00 8.85478526e+00 0.80546538 0.72720932 146.00 5.70383366e+00 6.44917834e+00 8.60962366e+00 0.84665148 0.65914140 146.25 5.61484607e+00 6.03117836e+00 8.24024324e+00 0.82113182 0.60420858 146.50 7.50585143e+00 5.48983675e+00 9.29925337e+00 0.63149540 0.67494660 146.75 9.33081153e+00 3.20925199e+00 9.86728646e+00 0.33126720 0.64148967 147.00 1.15231464e+01 2.50193600e+00 1.17916320e+01 0.21380413 0.69106911 147.25 9.81005114e+00 -3.62206926e-01 9.81673557e+00 -0.03690526 0.49491501 147.50 7.80596177e+00 -4.38898856e+00 8.95523644e+00 -0.51220795 0.49550618 147.75 5.87081252e+00 -3.46792689e+00 6.81857438e+00 -0.53355799 0.54802754 148.00 4.80548858e+00 -2.31756056e+00 5.33514830e+00 -0.44936624 0.53437625 148.25 4.34941676e+00 -8.20617327e-01 4.42615396e+00 -0.18648083 0.48632023 148.50 4.89592798e+00 -1.04697069e+00 5.00662146e+00 -0.21067212 0.61266953 148.75 4.03522655e+00 -1.66816649e+00 4.36644394e+00 -0.39200527 0.49948276 149.00 3.07433582e+00 -1.94500561e+00 3.63793727e+00 -0.56408782 0.46297238 149.25 3.27819035e+00 -7.17691743e-01 3.35583275e+00 -0.21552875 0.40939295 149.50 4.01132197e+00 -8.85742610e-01 4.10794887e+00 -0.21732340 0.54564542 149.75 3.75632949e+00 -1.24127159e+00 3.95610495e+00 -0.31915152 0.58487354 150.00 3.35688002e+00 -1.56395084e+00 3.70332090e+00 -0.43599262 0.55220954 150.25 2.84661805e+00 -1.52429716e+00 3.22904261e+00 -0.49162442 0.55579797 150.50 2.80504542e+00 -1.28078691e+00 3.08361718e+00 -0.42832985 0.59103155 150.75 2.41153609e+00 -6.99907119e-01 2.51105084e+00 -0.28247224 0.58327977 151.00 2.47431071e+00 -6.94689860e-01 2.56998200e+00 -0.27371421 0.62003516 151.25 2.69744143e+00 -3.98199696e-01 2.72667439e+00 -0.14656274 0.61345246 151.50 2.50198413e+00 -3.15201555e-01 2.52176061e+00 -0.12532043 0.56909054 151.75 2.42817616e+00 -4.04551609e-01 2.46164609e+00 -0.16509081 0.56551767 152.00 2.35690631e+00 -2.63207569e-01 2.37155762e+00 -0.11121422 0.55767615 152.25 2.05987580e+00 1.19121856e-01 2.06331731e+00 0.05776529 0.45154685 152.50 2.02761847e+00 5.30552038e-01 2.09588218e+00 0.25592481 0.32443728 152.75 3.15977640e+00 6.08657014e-01 3.21786424e+00 0.19029581 0.51807150 153.00 3.41284443e+00 1.06012304e-01 3.41449055e+00 0.03105276 0.45112544 153.25 2.19359543e+00 -1.73465702e+00 2.79658647e+00 -0.66909523 0.34587049 153.50 1.42403014e+00 -1.88824438e+00 2.36502192e+00 -0.92464091 0.30843751 153.75 1.69435868e+00 -2.32004870e+00 2.87288658e+00 -0.94001527 0.45803265 154.00 1.38750625e+00 -2.20706014e+00 2.60696913e+00 -1.00956429 0.43544986 154.25 6.36303908e-01 -2.68219679e+00 2.75663967e+00 -1.33786988 0.49536347 154.50 3.15865091e-01 -1.97876633e+00 2.00381809e+00 -1.41250450 0.34950045 154.75 -2.56857519e-01 -1.65948568e+00 1.67924641e+00 -1.72435915 0.35085415 155.00 -5.18645157e-01 -1.10208993e+00 1.21802915e+00 -2.01064976 0.20793984 155.25 -3.57084843e-01 -5.77376564e-01 6.78876485e-01 -2.12467956 0.13484596 155.50 -2.43154773e-01 -3.50046219e-01 4.26211919e-01 -2.17791334 0.05207981 155.75 -1.95239768e-01 1.66488750e-01 2.56587355e-01 2.43551006 0.01711938 156.00 -3.95397101e-01 5.61402757e-01 6.86667258e-01 2.18440373 0.10284473 156.25 -3.08327540e-01 1.04984337e+00 1.09418324e+00 1.85645328 0.28478518 156.50 -1.03852236e-01 1.30438673e+00 1.30851444e+00 1.65024641 0.29612182 156.75 2.58812987e-01 1.82424242e+00 1.84251040e+00 1.42986266 0.45897880 157.00 6.51019896e-01 2.22159566e+00 2.31501926e+00 1.28573557 0.54031735 157.25 8.03922632e-01 2.76307305e+00 2.87764909e+00 1.28766065 0.58672248 157.50 1.65917140e+00 2.96528579e+00 3.39790664e+00 1.06066458 0.50982159 157.75 2.66269713e+00 3.14176987e+00 4.11833387e+00 0.86774670 0.57189850 158.00 4.30596663e+00 2.92841031e+00 5.20739239e+00 0.59723271 0.56199345 158.25 5.99759045e+00 2.41441339e+00 6.46532932e+00 0.38271468 0.59738934 158.50 6.59563778e+00 -1.10791601e+00 6.68804273e+00 -0.16642341 0.49610935 158.75 6.18737089e+00 -3.71854707e+00 7.21880536e+00 -0.54114701 0.55832108 159.00 2.20314583e+00 -3.08097125e+00 3.78764246e+00 -0.95002004 0.36446476 159.25 1.21644514e+00 -2.56157506e+00 2.83573722e+00 -1.12744451 0.37237626 159.50 8.87776917e-01 -1.26249852e+00 1.54338924e+00 -0.95793232 0.22126942 159.75 1.13092433e+00 -1.11522138e+00 1.58830367e+00 -0.77840721 0.32294630 160.00 1.18832891e+00 -1.13676455e+00 1.64449361e+00 -0.76322447 0.38207055 160.25 1.20781829e+00 -1.15202160e+00 1.66912516e+00 -0.76175830 0.37272784 160.50 2.78068832e-01 -9.60418217e-01 9.99862704e-01 -1.28897351 0.13871311 160.75 -4.47070807e-02 -9.59854342e-01 9.60894938e-01 -1.61733963 0.12915095 161.00 -5.23591958e-01 -2.88568026e-01 5.97846171e-01 -2.63788114 0.04364984 161.25 -7.47008838e-01 2.04448441e-01 7.74481355e-01 2.87444525 0.08035665 161.50 -1.29320942e+00 1.22441876e+00 1.78089637e+00 2.38351129 0.24759659 161.75 -1.60364574e+00 2.11298389e+00 2.65261769e+00 2.21999985 0.26796489 162.00 -2.94073603e+00 2.36850805e+00 3.77594475e+00 2.46355959 0.19815219 162.25 -3.90987763e+00 2.32132988e+00 4.54705570e+00 2.60581166 0.16043716 162.50 -2.39699476e+00 5.31476488e+00 5.83029241e+00 1.99448714 0.09494724 162.75 -6.52542687e-01 2.05712431e+00 2.15814095e+00 1.87796739 0.00788098 163.00 -3.70622900e+00 -9.44534402e-01 3.82469327e+00 -2.89205403 0.01710626 163.25 -1.11801870e+00 1.36698261e+00 1.76595789e+00 2.25634106 0.00573244 163.50 3.95883793e+00 3.53349581e-01 3.97457591e+00 0.08901999 0.03469224 163.75 3.47453284e+00 2.23959163e-01 3.48174327e+00 0.06436830 0.03505328 164.00 4.60145489e+00 9.03791526e-01 4.68937375e+00 0.19394540 0.06138412 164.25 5.39638849e+00 1.93661228e-01 5.39986235e+00 0.03587180 0.09702408 164.50 8.33923790e+00 -8.86099490e-01 8.38618274e+00 -0.10585944 0.24003066 164.75 7.70591555e+00 1.09996416e+00 7.78402566e+00 0.14178502 0.30407681 165.00 9.92251445e+00 1.54100064e+00 1.00414628e+01 0.15407261 0.52513925 165.25 8.62822690e+00 1.53405451e+00 8.76353939e+00 0.17595620 0.52523529 165.50 9.78321111e+00 1.34217336e+00 9.87484931e+00 0.13634037 0.62735926 165.75 8.70887667e+00 1.48915146e+00 8.83527617e+00 0.16935449 0.66707357 166.00 9.13834546e+00 1.76958774e+00 9.30810392e+00 0.19127683 0.80898584 166.25 8.70515813e+00 1.50818367e+00 8.83483990e+00 0.17154884 0.79629568 166.50 8.37429869e+00 1.83834439e+00 8.57370332e+00 0.21609451 0.84999119 166.75 7.23807148e+00 2.13067061e+00 7.54515978e+00 0.28628362 0.82164494 167.00 7.22101954e+00 2.55679378e+00 7.66030793e+00 0.34030188 0.85791410 167.25 6.49185769e+00 2.64466664e+00 7.00988430e+00 0.38685401 0.77824287 167.50 6.18186740e+00 3.12458439e+00 6.92665230e+00 0.46799288 0.73923991 167.75 6.69257741e+00 3.79382672e+00 7.69309519e+00 0.51570351 0.58605554 168.00 9.05591811e+00 3.95143296e+00 9.88045926e+00 0.41143394 0.67436880 168.25 1.12971724e+01 2.26604096e+00 1.15221980e+01 0.19795779 0.77937395 168.50 1.21005140e+01 1.19807776e+00 1.21596805e+01 0.09868884 0.87133148 168.75 1.23944177e+01 4.60616688e-01 1.24029738e+01 0.03714614 0.89395685 169.00 1.25250856e+01 5.58357955e-01 1.25375250e+01 0.04454968 0.93169624 169.25 1.25208281e+01 6.08922931e-01 1.25356261e+01 0.04859451 0.89983083 169.50 1.30006030e+01 -3.10888086e-01 1.30043196e+01 -0.02390880 0.90044611 169.75 1.24660770e+01 -2.14447952e+00 1.26491845e+01 -0.17035782 0.85528358 170.00 1.34048075e+01 -3.05024188e+00 1.37474667e+01 -0.22373867 0.87177978 170.25 1.73871639e+01 -5.55449081e+00 1.82528309e+01 -0.30921237 0.89457003 170.50 1.80254936e+01 -8.17959452e+00 1.97945494e+01 -0.42599228 0.87624296 170.75 1.50380089e+01 -1.55223905e+01 2.16121799e+01 -0.80124681 0.77439877 171.00 6.97080737e+00 -1.79452285e+01 1.92515813e+01 -1.20028713 0.64857860 171.25 -7.69745834e+00 -1.20733061e+01 1.43183653e+01 -2.13837669 0.53187082 171.50 -1.00293549e+01 -8.19692976e+00 1.29528999e+01 -2.45639529 0.57570259 171.75 -4.75778731e+00 2.01479117e-01 4.76205144e+00 3.09927071 0.17958610 172.00 -2.64550676e+00 1.66990781e+00 3.12846578e+00 2.57853005 0.10546945 172.25 2.31004977e+00 -2.38431362e+00 3.31983153e+00 -0.80121664 0.08379843 172.50 2.77750366e+00 -5.91999001e+00 6.53917489e+00 -1.13211245 0.32449040 172.75 1.01351110e+00 -7.47020411e+00 7.53864406e+00 -1.43594590 0.62746058 173.00 1.87093702e-01 -5.23947833e+00 5.24281768e+00 -1.53510303 0.60252313 173.25 6.15264185e-01 -4.16193283e+00 4.20716471e+00 -1.42402797 0.64574059 173.50 1.19028189e+00 -3.52163745e+00 3.71735138e+00 -1.24485971 0.60296288 173.75 1.29944284e+00 -2.51732130e+00 2.83292398e+00 -1.09427237 0.46509468 174.00 1.67783794e+00 -2.47900092e+00 2.99342374e+00 -0.97579724 0.32092318 174.25 9.50894114e-01 -6.04078041e+00 6.11516374e+00 -1.41466503 0.63604878 174.50 6.03389979e-01 -6.19686686e+00 6.22617365e+00 -1.47373214 0.77466868 174.75 2.97065749e-01 -5.59900199e+00 5.60687715e+00 -1.51778912 0.82809187 175.00 3.90600210e-01 -4.73474173e+00 4.75082601e+00 -1.48848609 0.77938971 175.25 2.56632190e-01 -4.50743906e+00 4.51473886e+00 -1.51392247 0.82809849 175.50 1.43831408e-01 -4.53895525e+00 4.54123356e+00 -1.53911871 0.83184506 175.75 1.99918241e-01 -4.55165036e+00 4.55603867e+00 -1.52690239 0.84738801 176.00 -5.80367444e-01 -3.98543530e+00 4.02747078e+00 -1.71540198 0.77024187 176.25 -1.39066073e+00 -3.60140836e+00 3.86058020e+00 -1.93930075 0.81584355 176.50 -1.44900574e+00 -3.27317939e+00 3.57956994e+00 -1.98755515 0.78239016 176.75 -1.56327435e+00 -2.99142433e+00 3.37526980e+00 -2.05234848 0.83508316 177.00 -1.33209948e+00 -2.52225143e+00 2.85240974e+00 -2.05670094 0.79955941 177.25 -1.24568759e+00 -2.40478153e+00 2.70826730e+00 -2.04874355 0.84618774 177.50 -1.34914775e+00 -2.23196469e+00 2.60803873e+00 -2.11449350 0.82472615 177.75 -1.48588502e+00 -1.96221214e+00 2.46132704e+00 -2.21892127 0.84356949 178.00 -1.45908234e+00 -1.68644464e+00 2.23002619e+00 -2.28403883 0.80742895 178.25 -1.44247738e+00 -1.42033456e+00 2.02437429e+00 -2.36392897 0.78397335 178.50 -1.86282481e+00 -9.03630357e-01 2.07042606e+00 -2.68994722 0.66942820 178.75 -2.04809373e+00 -3.25144435e-01 2.07374223e+00 -2.98415188 0.56762458 179.00 -1.02455252e+00 1.42553014e+00 1.75551817e+00 2.19397379 0.40903949 179.25 -2.59324923e-01 2.38378930e+00 2.39785338e+00 1.67915705 0.63703736 179.50 9.70161533e-01 1.78735207e+00 2.03367667e+00 1.07350344 0.57920811 179.75 1.32231524e+00 1.26616854e+00 1.83076497e+00 0.76371060 0.58395646 180.00 1.71900011e+00 3.27247852e-01 1.74987215e+00 0.18812004 0.57994291 180.25 1.74381878e+00 7.12492046e-02 1.74527373e+00 0.04083543 0.68534366 180.50 1.55500714e+00 -4.78944939e-01 1.62709417e+00 -0.29878160 0.58614927 180.75 1.46412275e+00 -6.39818809e-01 1.59781837e+00 -0.41198907 0.57957895 181.00 1.33885279e+00 -9.54695606e-01 1.64437541e+00 -0.61944395 0.61817045 181.25 1.20319886e+00 -1.12639718e+00 1.64816811e+00 -0.75244229 0.65776823 181.50 1.01496386e+00 -9.86745467e-01 1.41556288e+00 -0.77130195 0.63915347 181.75 9.68244637e-01 -1.03448546e+00 1.41691843e+00 -0.81846137 0.66332883 182.00 8.95950936e-01 -1.05360998e+00 1.38304811e+00 -0.86609156 0.55770302 182.25 8.11187239e-01 -1.06205964e+00 1.33641140e+00 -0.91852984 0.57515257 182.50 7.96334044e-01 -1.09897363e+00 1.35716283e+00 -0.94373978 0.69634897 182.75 7.12042552e-01 -1.10179523e+00 1.31185263e+00 -0.99705710 0.67071607 183.00 6.95150653e-01 -1.17890508e+00 1.36859476e+00 -1.03801605 0.65844193 183.25 7.84443885e-01 -1.04178667e+00 1.30409803e+00 -0.92539114 0.61600080 183.50 4.54618377e-01 -9.72137914e-01 1.07318684e+00 -1.13336361 0.52675294 183.75 4.77579489e-01 -1.03797609e+00 1.14257452e+00 -1.13956973 0.56067496 184.00 6.09913934e-01 -1.01654928e+00 1.18548195e+00 -1.03038814 0.57358807 184.25 6.03853387e-01 -9.94170251e-01 1.16319104e+00 -1.02495754 0.51056142 184.50 6.75659405e-01 -8.49653980e-01 1.08555401e+00 -0.89897858 0.46011047 184.75 7.57307215e-01 -1.06606873e+00 1.30767609e+00 -0.95314201 0.47741662 185.00 8.85234723e-01 -1.60608182e+00 1.83388640e+00 -1.06705022 0.60975152 185.25 3.05018439e-01 -1.93249891e+00 1.95642232e+00 -1.41425149 0.53290056 185.50 -1.20704870e+00 -1.74837814e+00 2.12456883e+00 -2.17503801 0.50211523 185.75 -1.13569302e+00 -1.04995180e+00 1.54667302e+00 -2.39540364 0.30842451 186.00 -6.75465076e-01 -7.32186202e-02 6.79421839e-01 -3.03361690 0.16125958 186.25 -2.76105989e-01 -6.28491582e-02 2.83168737e-01 -2.91777927 0.04772841 186.50 -7.32860720e-02 -1.36388029e-01 1.54830690e-01 -2.06386402 0.01863431 186.75 5.30200954e-02 -3.48709612e-01 3.52717343e-01 -1.41990546 0.06614887 187.00 3.73725948e-01 -5.78597803e-01 6.88800771e-01 -0.99729702 0.22644608 187.25 3.37198981e-01 -6.77749407e-01 7.56998950e-01 -1.10912866 0.30798165 187.50 4.49648219e-01 -8.80395239e-01 9.88574377e-01 -1.09859804 0.50792857 187.75 3.02421508e-01 -9.50460755e-01 9.97413864e-01 -1.26274147 0.43584147 188.00 2.00226570e-01 -1.11036129e+00 1.12826985e+00 -1.39238802 0.55481225 188.25 7.15432411e-02 -1.17199784e+00 1.17417945e+00 -1.50982815 0.51198067 188.50 -5.71419393e-02 -1.26513455e+00 1.26642434e+00 -1.61593234 0.54505867 188.75 -1.22608198e-01 -1.16237171e+00 1.16882024e+00 -1.67588877 0.48355837 189.00 -1.56782433e-01 -1.02851721e+00 1.04039818e+00 -1.72206723 0.46769979 189.25 -1.81475957e-01 -9.23846983e-01 9.41502401e-01 -1.76476174 0.38202671 189.50 -8.38101269e-02 -9.98877363e-01 1.00238721e+00 -1.65450458 0.46573242 189.75 4.17156475e-02 -7.73528500e-01 7.74652525e-01 -1.51691948 0.32952865 190.00 1.53653691e-01 -8.40875581e-01 8.54798923e-01 -1.39005976 0.42011403 190.25 3.09963403e-01 -8.64409868e-01 9.18303725e-01 -1.22649500 0.45225003 190.50 3.97378400e-01 -9.96133072e-01 1.07246944e+00 -1.19122047 0.57417864 190.75 3.39022339e-01 -1.14367354e+00 1.19286433e+00 -1.28261541 0.61502942 191.00 2.69892016e-01 -1.20419956e+00 1.23407385e+00 -1.35031425 0.65727285 191.25 8.45033115e-02 -1.44997169e+00 1.45243200e+00 -1.51258289 0.46438889 191.50 -1.73785646e-01 -1.68120433e+00 1.69016255e+00 -1.67380023 0.33763880 191.75 -3.16391641e-01 3.89753965e-01 5.02007792e-01 2.25267465 0.02650121 192.00 2.66376223e-01 1.12563877e+00 1.15672768e+00 1.33842650 0.18987617 192.25 1.12394728e+00 5.19438237e-01 1.23817348e+00 0.43291620 0.34040405 192.50 1.47420047e+00 4.84656444e-01 1.55182437e+00 0.31762788 0.48731447 192.75 1.55352881e+00 6.06837102e-02 1.55471357e+00 0.03904200 0.54424970 193.00 1.46205514e+00 -2.26974164e-01 1.47956835e+00 -0.15401382 0.56580054 193.25 1.18604661e+00 -5.23620194e-01 1.29648936e+00 -0.41574921 0.49137316 193.50 1.09132122e+00 -5.56599820e-01 1.22506545e+00 -0.47163447 0.43893998 193.75 8.27548086e-01 -4.23138762e-01 9.29452660e-01 -0.47265955 0.47297163 194.00 7.70558918e-01 -3.31355910e-01 8.38783515e-01 -0.40611512 0.39485054 194.25 8.79661377e-01 -1.11066787e-01 8.86645346e-01 -0.12559625 0.39334885 194.50 9.57372089e-01 -1.60162347e-01 9.70676720e-01 -0.16575873 0.41498294 194.75 1.10852117e+00 -2.91235570e-01 1.14614019e+00 -0.25691826 0.47709766 195.00 1.21529346e+00 -2.04470278e-01 1.23237425e+00 -0.16668654 0.43576239 195.25 1.48845503e+00 -9.56136472e-02 1.49152282e+00 -0.06414870 0.59313313 195.50 1.67342887e+00 -3.34095227e-01 1.70645357e+00 -0.19705621 0.65381813 195.75 1.91563656e+00 -4.61819232e-01 1.97051780e+00 -0.23656471 0.81012009 196.00 1.93344918e+00 -5.90268696e-01 2.02154467e+00 -0.29630575 0.75509429 196.25 2.28771770e+00 -8.75066635e-01 2.44936602e+00 -0.36533532 0.77368048 196.50 2.10917267e+00 -1.23553492e+00 2.44441320e+00 -0.52990638 0.73429836 196.75 1.74596879e+00 -1.82415282e+00 2.52506248e+00 -0.80729421 0.81038606 197.00 1.55973547e+00 -2.04239377e+00 2.56985351e+00 -0.91859729 0.81928139 197.25 1.39731054e+00 -2.18973150e+00 2.59757594e+00 -1.00281828 0.83897653 197.50 9.03121058e-01 -2.27035702e+00 2.44338876e+00 -1.19219819 0.74476198 197.75 3.39219431e-01 -2.54705055e+00 2.56954010e+00 -1.43839420 0.82152766 198.00 -3.13000924e-01 -2.14907603e+00 2.17174984e+00 -1.71542384 0.69066489 198.25 -9.04474760e-01 -1.56651680e+00 1.80888073e+00 -2.09441706 0.67104594 198.50 -7.24194968e-01 -8.09519310e-01 1.08617672e+00 -2.30061929 0.47222792 198.75 -6.06840537e-01 -4.01902874e-01 7.27860809e-01 -2.55662794 0.42502514 199.00 -3.17875479e-01 -2.55940547e-01 4.08105849e-01 -2.46371342 0.12593085 199.25 1.97735654e-02 -7.81021503e-02 8.05663688e-02 -1.32283102 0.00726431 199.50 2.42996761e-01 -9.09807039e-02 2.59470450e-01 -0.35825434 0.06779486 199.75 3.45869141e-01 -1.13297367e-01 3.63952959e-01 -0.31655726 0.13369195 200.00 3.37030022e-01 5.44065875e-02 3.41393194e-01 0.16004877 0.10200281 200.25 3.55556297e-01 8.82465058e-02 3.66343727e-01 0.24327703 0.12431236 200.50 3.68711935e-01 -1.69478736e-01 4.05797403e-01 -0.43085049 0.07190454 200.75 4.40045423e-01 -2.91631671e-01 5.27910036e-01 -0.58527285 0.11443649 201.00 2.90415398e-01 -2.55268334e-01 3.86656211e-01 -0.72107779 0.05278746 201.25 2.44821673e-01 -3.72791223e-01 4.45994336e-01 -0.98970736 0.06474329 201.50 4.68461396e-01 -6.60537535e-01 8.09793749e-01 -0.95391428 0.18049929 201.75 5.77960996e-01 -7.09233538e-01 9.14904981e-01 -0.88703024 0.27282172 202.00 2.26599720e-01 -5.37020701e-01 5.82871055e-01 -1.17150583 0.12346161 202.25 2.21895002e-01 -4.53618599e-01 5.04982401e-01 -1.11585306 0.09220940 202.50 -9.30377546e-02 -4.36756258e-01 4.46555766e-01 -1.78067906 0.06261015 202.75 -5.58844231e-02 -3.20752689e-01 3.25584638e-01 -1.74329381 0.03299275 203.00 -2.66426267e-02 -5.12843711e-01 5.13535297e-01 -1.62270044 0.08664334 203.25 -1.69299439e-02 -5.74741793e-01 5.74991088e-01 -1.60024442 0.09800376 203.50 -1.38485319e-01 -2.66630507e-01 3.00449681e-01 -2.04983563 0.02951664 203.75 -2.93726067e-01 -1.69080336e-01 3.38914683e-01 -2.61927788 0.03874689 204.00 -1.66769753e-01 -4.48602448e-02 1.72697980e-01 -2.87881769 0.01298422 204.25 -1.18430231e-01 1.95051747e-02 1.20025712e-01 2.97836044 0.00713941 204.50 -1.59879139e-01 1.53632559e-01 2.21730246e-01 2.37611640 0.02681536 204.75 -1.08682990e-01 9.20697682e-02 1.42438880e-01 2.43876099 0.00992177 205.00 2.30899063e-01 -2.24300808e-01 3.21908729e-01 -0.77090389 0.05267681 205.25 2.28916732e-01 -1.35960061e-01 2.66248021e-01 -0.53594285 0.03203764 205.50 4.94252479e-01 -5.57699180e-02 4.97388979e-01 -0.11236164 0.10880523 205.75 4.20888169e-01 -3.91820970e-02 4.22708040e-01 -0.09282630 0.08108014 206.00 3.03890791e-01 -3.34902143e-02 3.05730612e-01 -0.10976184 0.05607653 206.25 4.81440288e-01 -1.30716353e-01 4.98870239e-01 -0.26511967 0.12647228 206.50 7.67458926e-01 -3.02617506e-02 7.68055322e-01 -0.03941068 0.28643234 206.75 6.77556252e-01 -5.12438648e-02 6.79491286e-01 -0.07548671 0.18647661 207.00 8.49472561e-01 -1.50011275e-01 8.62616378e-01 -0.17479133 0.30227653 207.25 8.53550694e-01 -1.99673034e-01 8.76594609e-01 -0.22979985 0.27662141 207.50 1.04607312e+00 -2.55507883e-01 1.07682555e+00 -0.23956370 0.48742699 207.75 8.59883016e-01 -3.63695399e-01 9.33634374e-01 -0.40014077 0.37376405 208.00 9.94928628e-01 -4.80166569e-01 1.10473658e+00 -0.44964239 0.43549805 208.25 9.56361595e-01 -3.67398602e-01 1.02450438e+00 -0.36677956 0.40497509 208.50 9.87200232e-01 -4.20475527e-01 1.07301629e+00 -0.40265581 0.40119691 208.75 8.69833693e-01 -3.27300135e-01 9.29374000e-01 -0.35989150 0.21783923 209.00 6.31263058e-01 -3.56367216e-01 7.24907333e-01 -0.51393054 0.13829169 209.25 3.76963691e-01 -3.61795638e-01 5.22491826e-01 -0.76486926 0.07101587 209.50 2.11930233e-01 -4.50381186e-01 4.97752585e-01 -1.13097893 0.06879643 209.75 -4.75140350e-02 -2.99483884e-01 3.03229584e-01 -1.72813800 0.02835684 210.00 -1.37131251e-01 -2.69039699e-01 3.01972415e-01 -2.04217886 0.03334291 210.25 -1.63356426e-02 -1.15047369e-01 1.16201335e-01 -1.71184405 0.00546244 210.50 5.19760601e-02 -3.99135983e-02 6.55332446e-02 -0.65487333 0.00186362 210.75 1.61942242e-01 4.54262641e-02 1.68192851e-01 0.27348068 0.01068879 211.00 2.51446179e-01 1.19449393e-01 2.78376253e-01 0.44348876 0.02978868 211.25 9.19175598e-02 -1.03395837e-01 1.38345715e-01 -0.84409915 0.00742340 211.50 8.85943872e-02 -1.04095098e-01 1.36692190e-01 -0.86566930 0.00668485 211.75 2.05222968e-02 1.19071998e-01 1.20827585e-01 1.40012113 0.00466521 212.00 -4.45471070e-03 9.67816361e-02 9.68841036e-02 1.61679233 0.00282340 212.25 -7.62851852e-02 2.38653247e-02 7.99311153e-02 2.83839487 0.00169817 212.50 -9.68315298e-02 9.82700902e-02 1.37961429e-01 2.34882123 0.00502328 212.75 -1.40979514e-01 -1.53905460e-02 1.41817108e-01 -3.03285459 0.00711022 213.00 -1.50497433e-01 -4.32347094e-02 1.56584537e-01 -2.86184723 0.00874466 213.25 -1.31784190e-01 -3.73550188e-02 1.36976167e-01 -2.86538209 0.00678710 213.50 -1.22667070e-01 -1.52861801e-01 1.95994745e-01 -2.24704180 0.01318692 213.75 5.25896535e-02 -3.77722068e-02 6.47488321e-02 -0.62286566 0.00135418 214.00 -1.56078840e-02 -9.93127568e-02 1.00531735e-01 -1.72668019 0.00327035 214.25 -4.66374098e-02 -2.96082245e-02 5.52421483e-02 -2.57593442 0.00091817 214.50 3.80927235e-02 2.37772384e-02 4.49044836e-02 0.55801930 0.00059470 214.75 6.78256564e-02 1.42465558e-01 1.57787056e-01 1.12646344 0.00660317 215.00 1.18494336e-01 -4.49077893e-02 1.26718654e-01 -0.36226136 0.00393674 215.25 2.18727892e-01 -4.14579430e-02 2.22622218e-01 -0.18731908 0.01079132 215.50 2.03027674e-01 5.73718889e-02 2.10978127e-01 0.27540103 0.01042733 215.75 6.41499093e-02 2.42213057e-01 2.50564115e-01 1.31189160 0.01865368 216.00 4.34326131e-04 8.79319089e-02 8.79329815e-02 1.56585702 0.00227259 216.25 -3.86750619e-01 1.01910381e-01 3.99952206e-01 2.88394517 0.04849207 216.50 -3.29938873e-01 2.12503413e-01 3.92450456e-01 2.56939813 0.05338036 216.75 -1.63942582e-01 9.29408538e-02 1.88454696e-01 2.62585872 0.01404408 217.00 -1.42361995e-01 1.57927295e-01 2.12621655e-01 2.30440649 0.01830078 217.25 -5.56143667e-03 2.66592810e-01 2.66650813e-01 1.59165447 0.02991210 217.50 8.48476915e-03 2.04804437e-01 2.04980118e-01 1.52939136 0.01964839 217.75 -3.80711110e-02 8.94316296e-02 9.71978697e-02 1.97326036 0.00781807 218.00 -1.50419759e-02 6.16240010e-02 6.34332605e-02 1.81020761 0.00273144 218.25 1.13689673e-01 -8.00100448e-02 1.39021398e-01 -0.61324383 0.01662140 218.50 -4.07277925e-02 -1.03760356e-01 1.11467325e-01 -1.94483598 0.01171948 218.75 -1.18515850e-01 -2.04507390e-01 2.36366832e-01 -2.09601987 0.05957298 219.00 -8.83857629e-02 -9.69679391e-02 1.31205275e-01 -2.30992592 0.01692178 219.25 -1.90454121e-01 -9.39257164e-02 2.12355391e-01 -2.68342625 0.06705272 219.50 -2.54879245e-01 -2.51713881e-01 3.58222427e-01 -2.36244274 0.14764162 219.75 -2.52558382e-01 -2.24398685e-01 3.37846868e-01 -2.41516635 0.17807288 220.00 -4.01966918e-01 -1.42699941e-01 4.26545046e-01 -2.80046673 0.23396108 220.25 -4.84585173e-01 -6.93623128e-02 4.89524178e-01 -2.99942085 0.33992004 220.50 -5.76319848e-01 -3.85438516e-02 5.77607302e-01 -3.07481283 0.37661636 220.75 -5.58069051e-01 -2.62406475e-02 5.58685634e-01 -3.09460683 0.38893572 221.00 -4.34181773e-01 3.08857028e-01 5.32828749e-01 2.52328700 0.26718103 221.25 -2.68471025e-01 5.30835033e-01 5.94863449e-01 2.03903516 0.38690045 221.50 1.62310161e-01 5.59666414e-01 5.82727281e-01 1.28852753 0.34814829 221.75 4.11714929e-01 4.77376310e-01 6.30394578e-01 0.85911657 0.40638664 222.00 5.02763096e-01 4.00115941e-01 6.42544549e-01 0.67219550 0.48039855 222.25 5.11178666e-01 3.38412483e-01 6.13047010e-01 0.58478147 0.48961688 222.50 5.70951798e-01 1.67781464e-01 5.95093754e-01 0.28581682 0.48853148 222.75 6.19790995e-01 6.81353989e-02 6.23524908e-01 0.10949319 0.52229194 223.00 5.30431227e-01 -1.19718990e-01 5.43773780e-01 -0.22198180 0.39969477 223.25 5.50979717e-01 -2.17641084e-01 5.92407200e-01 -0.37619505 0.52162498 223.50 4.12516877e-01 -2.45412489e-01 4.79997358e-01 -0.53667216 0.46318757 223.75 3.92941858e-01 -2.51393660e-01 4.66478377e-01 -0.56915226 0.44991912 224.00 4.60140593e-01 -2.37056058e-01 5.17614664e-01 -0.47571915 0.48107013 224.25 5.05821426e-01 -2.90633092e-01 5.83372016e-01 -0.52151593 0.54436649 224.50 4.39481706e-01 -4.93021532e-01 6.60465291e-01 -0.84275036 0.63249096 224.75 3.65214015e-01 -5.51198267e-01 6.61211620e-01 -0.98562695 0.64068743 225.00 2.24259642e-01 -5.74601761e-01 6.16814049e-01 -1.19869110 0.63167584 225.25 1.50034732e-01 -5.34202777e-01 5.54872083e-01 -1.29699286 0.58641845 225.50 5.84465939e-02 -5.61326560e-01 5.64361154e-01 -1.46704791 0.59141203 225.75 5.36269444e-02 -5.28308318e-01 5.31023096e-01 -1.46963591 0.47119947 226.00 -5.19234664e-02 -3.49933204e-01 3.53764461e-01 -1.71810260 0.34675222 226.25 -4.40356321e-02 -3.01821647e-01 3.05017120e-01 -1.71567363 0.29895654 226.50 1.05615092e-01 -2.42543875e-01 2.64541262e-01 -1.16011005 0.23872308 226.75 2.35089306e-01 -2.30994340e-01 3.29583626e-01 -0.77661249 0.25886296 227.00 4.56289577e-01 -3.90691463e-01 6.00699589e-01 -0.70810314 0.34317001 227.25 5.90229573e-01 -6.61283876e-01 8.86378764e-01 -0.84211198 0.28839544 227.50 2.20372301e-01 -1.70183015e+00 1.71603899e+00 -1.44202154 0.39735473 227.75 -9.86115274e-01 -1.72874148e+00 1.99021869e+00 -2.08918467 0.43559613 228.00 -1.98805586e+00 -1.01886946e+00 2.23393399e+00 -2.66799878 0.62918913 228.25 -1.99259416e+00 1.48956320e-01 1.99815402e+00 3.06697647 0.63132248 228.50 -1.58620397e+00 1.00286474e+00 1.87664081e+00 2.57780256 0.70697181 228.75 -1.12256578e+00 1.16812915e+00 1.62008631e+00 2.33630648 0.63353925 229.00 -7.71435173e-01 1.30603513e+00 1.51685200e+00 2.10432695 0.59923090 229.25 -2.49608745e-01 1.05173574e+00 1.08094986e+00 1.80381547 0.23777386 229.50 5.04414508e-01 2.37593931e-01 5.57570508e-01 0.44020349 0.06894552 229.75 8.36573704e-02 -1.22008144e-01 1.47934252e-01 -0.96975244 0.00828489 230.00 -4.97417832e-02 -1.74893234e-01 1.81829284e-01 -1.84789183 0.02136973 230.25 -2.45816673e-01 7.16590206e-02 2.56048535e-01 2.85793918 0.04591183 230.50 -2.41211628e-01 2.18250212e-01 3.25294028e-01 2.40612754 0.07677484 230.75 -2.64457726e-01 3.18368900e-01 4.13879989e-01 2.26395745 0.10413364 231.00 -2.49035105e-01 3.26665774e-01 4.10766371e-01 2.22215751 0.11745068 231.25 -3.24813542e-01 2.58398632e-01 4.15058659e-01 2.46958381 0.09573197 231.50 -4.13173267e-01 2.37968347e-01 4.76802981e-01 2.61904253 0.10735645 231.75 -4.13457420e-01 2.24300561e-01 4.70380463e-01 2.64452600 0.07125332 232.00 -2.85101230e-01 3.55027587e-01 4.55332075e-01 2.24738797 0.06061410 232.25 -4.19137927e-01 3.16534717e-01 5.25234071e-01 2.49476918 0.06108996 232.50 -5.07646704e-01 2.46071966e-01 5.64142348e-01 2.69023489 0.06529815 232.75 -8.38563947e-01 -3.20414425e-02 8.39175874e-01 -3.10340134 0.13700381 233.00 -9.86923581e-01 1.68958764e-01 1.00128179e+00 2.97203895 0.19661535 233.25 -9.38679875e-01 8.97398110e-03 9.38722770e-01 3.13203273 0.23874024 233.50 -9.86922629e-01 -7.30117683e-02 9.89619620e-01 -3.06774795 0.26509353 233.75 -8.03341321e-01 1.68850214e-01 8.20894435e-01 2.93442338 0.24993171 234.00 -7.41437026e-01 2.21070367e-01 7.73693073e-01 2.85182045 0.27749677 234.25 -7.07502813e-01 1.31424267e-01 7.19605842e-01 2.95792813 0.34877084 234.50 -7.16311234e-01 1.33794542e-01 7.28699364e-01 2.95693774 0.35956476 234.75 -5.51737428e-01 3.84234890e-01 6.72347112e-01 2.53328085 0.28355522 235.00 -6.30501177e-01 3.49018847e-01 7.20656568e-01 2.63602203 0.37395247 235.25 -4.64241248e-01 3.16612108e-01 5.61928076e-01 2.54305027 0.39290668 235.50 -4.46508517e-01 2.90475195e-01 5.32677853e-01 2.56483234 0.37276739 235.75 -3.47047907e-01 3.73840883e-01 5.10097300e-01 2.31904500 0.47948445 236.00 -4.05342625e-01 3.82033016e-01 5.57002575e-01 2.38579003 0.51080074 236.25 -5.92111997e-01 4.15131570e-01 7.23139570e-01 2.53012672 0.58454255 236.50 -5.65455604e-01 4.74507281e-01 7.38171524e-01 2.44342599 0.51021858 236.75 -4.35149112e-01 5.66241795e-01 7.14132004e-01 2.22602413 0.45163461 237.00 -4.23251883e-01 5.33733786e-01 6.81185665e-01 2.24125552 0.39783681 237.25 -3.34818469e-01 3.85593659e-01 5.10671986e-01 2.28583009 0.20127867 237.50 -3.98768331e-01 3.90146497e-01 5.57880337e-01 2.36712278 0.15383117 237.75 -6.00895307e-01 1.97410753e-01 6.32492036e-01 2.82417339 0.17779808 238.00 -3.00944360e-01 -2.60143670e-01 3.97796728e-01 -2.42878382 0.06652421 238.25 -1.37102041e-02 -8.73660362e-01 8.73767931e-01 -1.58648787 0.23838075 238.50 8.03120311e-02 -6.42549575e-01 6.47549210e-01 -1.44645155 0.24928815 238.75 5.88999280e-02 -5.20768070e-01 5.24088336e-01 -1.45817289 0.35135838 239.00 4.87640829e-02 -4.82372548e-01 4.84831116e-01 -1.47004644 0.39851127 239.25 3.30764798e-02 -3.71722883e-01 3.73191579e-01 -1.48204851 0.43902455 239.50 6.11798413e-02 -2.58277990e-01 2.65425118e-01 -1.33820735 0.27053463 239.75 4.09005836e-02 -2.40708587e-01 2.44158722e-01 -1.40248643 0.29341624 240.00 -2.04574175e-03 -1.82925910e-01 1.82937348e-01 -1.58197931 0.19124128 240.25 9.46475380e-03 -1.15501644e-01 1.15888788e-01 -1.48903426 0.13378436 240.50 7.05252276e-03 -6.82588939e-02 6.86222608e-02 -1.46784144 0.05392816 240.75 2.31736261e-02 -4.88038649e-02 5.40262360e-02 -1.12748525 0.04441685 241.00 3.09049046e-02 -5.57301715e-02 6.37257024e-02 -1.06447014 0.06280476 241.25 3.08429369e-02 -3.05978070e-02 4.34455124e-02 -0.78140849 0.05513654 241.50 2.10643831e-02 -3.18530739e-03 2.13038592e-02 -0.15008063 0.01877007 241.75 2.12824178e-02 6.07881696e-03 2.21335339e-02 0.27821826 0.02193888 242.00 1.44891282e-02 2.61614917e-02 2.99058269e-02 1.06501418 0.02460262 242.25 4.30661612e-03 4.11055035e-02 4.13304895e-02 1.46640735 0.04687833 242.50 -4.21292185e-02 3.23775253e-02 5.31335600e-02 2.48633808 0.03526180 242.75 -9.66264879e-02 1.03479605e-01 1.41579330e-01 2.32196045 0.18904208 243.00 -1.34565681e-01 1.73233452e-01 2.19357588e-01 2.23122254 0.34602828 243.25 -1.16354319e-01 2.29125095e-01 2.56975946e-01 2.04068039 0.40316452 243.50 -1.46567855e-01 4.10098982e-01 4.35503514e-01 1.91404501 0.47586387 243.75 -1.16409684e-01 4.99699704e-01 5.13079925e-01 1.79967349 0.52690717 244.00 -7.92406453e-02 5.88719116e-01 5.94028011e-01 1.70459061 0.57387582 244.25 -1.87985196e-02 7.40689696e-01 7.40928208e-01 1.59617063 0.64085849 244.50 3.95260548e-01 7.94301774e-01 8.87212607e-01 1.10905443 0.59997222 244.75 7.21441639e-01 7.85219519e-01 1.06632440e+00 0.82770351 0.65737796 245.00 1.07243375e+00 4.97138047e-01 1.18205769e+00 0.43407353 0.70230760 245.25 1.10641665e+00 1.98188259e-01 1.12402686e+00 0.17724648 0.66574167 245.50 1.00817307e+00 -8.67506688e-02 1.01189852e+00 -0.08583597 0.74344028 245.75 8.63368649e-01 -1.47135775e-01 8.75816396e-01 -0.16879888 0.67261960 246.00 6.65949928e-01 -2.72302763e-01 7.19470709e-01 -0.38814981 0.63487306 246.25 6.12887529e-01 -2.85612968e-01 6.76170016e-01 -0.43608947 0.58251708 246.50 4.76226548e-01 -3.35992835e-01 5.82823224e-01 -0.61442875 0.57924896 246.75 4.01601172e-01 -3.26636560e-01 5.17662963e-01 -0.68281972 0.47602812 247.00 4.00566749e-01 -2.10867935e-01 4.52679806e-01 -0.48456263 0.36555704 247.25 3.14750529e-01 -2.17866759e-01 3.82797361e-01 -0.60546422 0.23428555 247.50 2.98431671e-01 -2.06027645e-01 3.62641493e-01 -0.60423217 0.22359399 247.75 2.65033546e-01 -1.88974024e-01 3.25505703e-01 -0.61941039 0.17150683 248.00 1.79884417e-01 -1.22446001e-01 2.17603829e-01 -0.59765015 0.10396514 248.25 1.94351904e-01 -1.37040219e-01 2.37808083e-01 -0.61414984 0.08427213 248.50 1.30851223e-01 -2.17548093e-01 2.53868500e-01 -1.02928796 0.08548309 248.75 1.73907697e-01 -1.98011394e-01 2.63538231e-01 -0.85011663 0.06985975 249.00 2.57576556e-01 -1.89298325e-01 3.19655342e-01 -0.63378026 0.13273515 249.25 2.16387726e-01 -1.94990953e-01 2.91281856e-01 -0.73343264 0.09623999 249.50 2.83339094e-01 -1.45249375e-01 3.18399785e-01 -0.47370399 0.10343694 249.75 7.07044406e-02 -2.96061901e-01 3.04387528e-01 -1.33637077 0.02696845 250.00 1.09490873e-01 -3.31323227e-01 3.48946030e-01 -1.25162910 0.00890348 250.25 5.04356966e-02 -1.26274919e-01 1.35974684e-01 -1.19079710 0.00236779 250.50 1.65313689e-01 -1.36758826e-01 2.14549743e-01 -0.69114841 0.05375478 250.75 1.89611897e-01 -2.36895174e-01 3.03433675e-01 -0.89580896 0.12367717 251.00 2.54536876e-01 -2.24127801e-01 3.39149366e-01 -0.72195445 0.20491738 251.25 2.33958572e-01 -3.62643606e-01 4.31563435e-01 -0.99784001 0.27029690 251.50 1.76015181e-01 -4.08149336e-01 4.44485348e-01 -1.16364219 0.38734606 251.75 1.65964798e-01 -2.58948075e-01 3.07568561e-01 -1.00083129 0.22824268 252.00 1.92985506e-01 -1.60118499e-01 2.50761519e-01 -0.69258534 0.17761490 252.25 1.13610976e-01 -2.66177733e-01 2.89409812e-01 -1.16738197 0.20334651 252.50 1.08843293e-01 -2.34801171e-01 2.58801955e-01 -1.13672729 0.23249098 252.75 1.69887413e-02 -2.43302980e-01 2.43895382e-01 -1.50108402 0.18610870 253.00 1.53517898e-02 -2.22169371e-01 2.22699140e-01 -1.50180650 0.18076981 253.25 6.01112410e-02 -1.87631832e-01 1.97025546e-01 -1.26075957 0.11290885 253.50 1.45185949e-01 -2.02555477e-01 2.49214127e-01 -0.94890293 0.19260017 253.75 1.20305420e-01 -1.54810074e-01 1.96060076e-01 -0.91016549 0.13967527 254.00 1.26887570e-01 -1.91651635e-01 2.29849525e-01 -0.98597999 0.21025404 254.25 1.58579410e-01 -7.43859418e-02 1.75159064e-01 -0.43860456 0.13092907 254.50 1.56856438e-01 -1.57463567e-01 2.22258221e-01 -0.78732973 0.20644714 254.75 2.09581587e-01 -2.13243564e-01 2.98993744e-01 -0.79405868 0.34976045 255.00 2.28733443e-01 -1.79983756e-01 2.91055219e-01 -0.66668414 0.33022183 255.25 1.49188954e-01 -1.90584707e-01 2.42032797e-01 -0.90663399 0.21467104 255.50 1.61162885e-01 -2.02391135e-01 2.58719244e-01 -0.89831911 0.26277098 255.75 1.38870376e-01 -2.10473439e-01 2.52158779e-01 -0.98756264 0.26497500 256.00 1.29614546e-01 -2.20104365e-01 2.55432696e-01 -1.03859515 0.24385481 256.25 1.40359470e-01 -2.79554177e-01 3.12811954e-01 -1.10548351 0.27885951 256.50 1.06640434e-01 -2.33670326e-01 2.56854051e-01 -1.14265666 0.19301412 256.75 1.46575243e-01 -1.34103945e-01 1.98665976e-01 -0.74099480 0.13074761 257.00 1.49827359e-01 -1.28750573e-01 1.97547330e-01 -0.70988354 0.12108314 257.25 1.73195690e-01 -2.09130806e-01 2.71537182e-01 -0.87911349 0.20784388 257.50 1.75802978e-01 -2.94820897e-01 3.43257991e-01 -1.03309866 0.31322089 257.75 1.84708732e-01 -3.24919868e-01 3.73751570e-01 -1.05387979 0.40650640 258.00 1.07963985e-01 -3.25764035e-01 3.43188620e-01 -1.25077078 0.33231411 258.25 -7.88559285e-03 -3.45460928e-01 3.45550915e-01 -1.59361866 0.33304566 258.50 -5.45942788e-02 -2.75883787e-01 2.81233709e-01 -1.76616095 0.20608594 258.75 -5.23159192e-02 -6.73453023e-02 8.52780461e-02 -2.23124932 0.03208674 259.00 -5.22491844e-02 -8.01392940e-02 9.56675688e-02 -2.14856192 0.03755952 259.25 -8.00238832e-02 -6.86629658e-02 1.05443941e-01 -2.43245467 0.04532519 259.50 1.01438131e-02 -1.40978830e-01 1.41343296e-01 -1.49896737 0.06535284 259.75 3.36638279e-02 -2.52817740e-01 2.55049138e-01 -1.43842048 0.18916918 260.00 -3.56351177e-02 -1.97230139e-01 2.00423525e-01 -1.74954576 0.10411271 260.25 1.47673261e-02 -2.19340648e-01 2.19837199e-01 -1.50357179 0.16265700 260.50 1.16539124e-03 -1.83062341e-01 1.83066050e-01 -1.56443032 0.08899935 260.75 -4.69255841e-02 -1.10075780e-01 1.19660719e-01 -1.97376972 0.05125925 261.00 -6.70536370e-02 -1.04056393e-01 1.23789835e-01 -2.14322268 0.04782814 261.25 -8.49104301e-02 -1.43941449e-01 1.67119484e-01 -2.10375300 0.09543853 261.50 -1.37476933e-01 -1.57323880e-02 1.38374185e-01 -3.02765174 0.07015896 261.75 -2.09837315e-01 8.03198911e-02 2.24684186e-01 2.77602547 0.19805185 262.00 -2.02078083e-01 6.00403720e-02 2.10808913e-01 2.85278501 0.13256984 262.25 -1.50409855e-01 1.19315723e-01 1.91987932e-01 2.47096847 0.13075977 262.50 -9.44262915e-02 1.25243361e-01 1.56850961e-01 2.21681586 0.12825496 262.75 -7.48392769e-02 1.10320361e-01 1.33309787e-01 2.16686532 0.12612489 263.00 -6.39331300e-02 1.04378178e-01 1.22401999e-01 2.12036676 0.11221398 263.25 -7.29281778e-02 7.24486740e-02 1.02797517e-01 2.35949283 0.09849214 263.50 -4.56552181e-03 5.14966288e-02 5.16986148e-02 1.65922185 0.02743761 263.75 -1.89655117e-03 4.95743796e-02 4.96106443e-02 1.60903436 0.02833587 264.00 2.17250975e-02 4.36824285e-03 2.21599054e-02 0.19842320 0.00804562 264.25 1.74583558e-02 6.60026299e-03 1.86643419e-02 0.36144855 0.00658503 264.50 -1.23421724e-02 4.67902934e-02 4.83907096e-02 1.82869835 0.03440344 264.75 5.63447499e-03 2.48902513e-02 2.55200297e-02 1.34817565 0.01153769 265.00 -2.86142870e-02 4.79229453e-02 5.58156439e-02 2.10907300 0.06331328 265.25 -2.02543309e-02 4.18174773e-02 4.64643877e-02 2.02184643 0.04322864 265.50 -1.60863824e-02 2.11937415e-03 1.62253950e-02 3.01059753 0.00464438 265.75 -2.02873329e-02 -5.69836003e-04 2.02953342e-02 -3.11351177 0.00838537 266.00 -3.87133108e-02 1.57492545e-02 4.17942514e-02 2.75522292 0.03081766 266.25 -4.54929262e-02 2.67546027e-02 5.27770320e-02 2.60996563 0.04334604 266.50 -6.34505699e-02 3.31853018e-02 7.16047420e-02 2.65970671 0.09237267 266.75 -6.15019035e-02 4.70302614e-02 7.74230561e-02 2.48875224 0.08764720 267.00 -1.09173720e-01 7.26232685e-02 1.31122234e-01 2.55460035 0.27648313 267.25 -7.57612925e-02 8.67713695e-02 1.15191336e-01 2.28855712 0.22255787 267.50 -6.11820247e-02 6.94519029e-02 9.25570471e-02 2.29297311 0.13574390 267.75 -6.93879133e-02 9.45182510e-02 1.17253496e-01 2.20405773 0.19574289 268.00 -5.22027825e-02 1.22398906e-01 1.33066234e-01 1.97393438 0.25542318 268.25 -4.08887332e-02 1.25349887e-01 1.31850228e-01 1.88611032 0.20020466 268.50 -3.82907570e-02 1.32418160e-01 1.37843212e-01 1.85228377 0.27570776 268.75 -3.34470403e-02 1.36417329e-01 1.40457795e-01 1.81123506 0.28990143 269.00 -3.03071745e-04 1.49322763e-01 1.49323070e-01 1.57282597 0.35725297 269.25 1.62706678e-02 1.54084709e-01 1.54941383e-01 1.46559060 0.30633549 269.50 3.08089710e-02 1.69889040e-01 1.72660009e-01 1.39139838 0.44480151 269.75 3.13736759e-02 1.53556187e-01 1.56728459e-01 1.36925617 0.35944719 270.00 1.13944550e-02 1.51709505e-01 1.52136805e-01 1.49583002 0.40761494 270.25 -1.09524713e-02 1.60825669e-01 1.61198178e-01 1.63879285 0.40642485 270.50 1.01424913e-02 1.63488930e-01 1.63803237e-01 1.50883795 0.41005299 270.75 2.66626399e-02 1.98714825e-01 2.00495581e-01 1.43741753 0.40426176 271.00 1.49084803e-02 2.11202152e-01 2.11727683e-01 1.50032454 0.47748667 271.25 -1.13991327e-02 2.36375338e-01 2.36650039e-01 1.61898371 0.42392590 271.50 -2.70988464e-02 3.04551800e-01 3.05755043e-01 1.65954204 0.60958837 271.75 -1.82858260e-02 3.49079211e-01 3.49557816e-01 1.62313152 0.59430463 272.00 -3.81395840e-02 4.28846470e-01 4.30539107e-01 1.65949824 0.64054121 272.25 2.70637228e-02 4.56091624e-01 4.56893877e-01 1.51152748 0.55184765 272.50 1.42688797e-01 5.54268207e-01 5.72340229e-01 1.31883106 0.65016856 272.75 2.76852063e-01 6.51068864e-01 7.07486912e-01 1.16873342 0.66973105 273.00 3.49964858e-01 6.40212385e-01 7.29621339e-01 1.07053744 0.64502657 273.25 3.28168375e-01 5.34333096e-01 6.27061671e-01 1.02002686 0.50577322 273.50 4.01976834e-01 5.70224886e-01 6.97668830e-01 0.95675968 0.54787385 273.75 4.50193980e-01 3.81475053e-01 5.90082906e-01 0.70295771 0.27175026 274.00 4.99656103e-01 2.09404214e-01 5.41762260e-01 0.39685988 0.18494666 274.25 4.19376994e-01 3.26260567e-02 4.20644175e-01 0.07764011 0.11528353 274.50 6.10737467e-01 -2.21553156e-02 6.11139192e-01 -0.03626043 0.25318662 274.75 5.74149308e-01 -1.39420450e-01 5.90834570e-01 -0.23821875 0.27744097 275.00 6.26212679e-01 -2.60722103e-01 6.78320230e-01 -0.39451916 0.38549265 275.25 6.81586301e-01 -3.44897397e-01 7.63880947e-01 -0.46845328 0.51493120 275.50 7.24950668e-01 -4.05405817e-01 8.30606614e-01 -0.50989319 0.52937605 275.75 6.23259227e-01 -6.13531981e-01 8.74570498e-01 -0.77753342 0.50069607 276.00 5.68098325e-01 -6.04510362e-01 8.29559211e-01 -0.81644035 0.46889432 276.25 5.77443040e-01 -7.68373415e-01 9.61165006e-01 -0.92632724 0.43523489 276.50 3.76962053e-01 -7.35949533e-01 8.26874902e-01 -1.09742705 0.37480789 276.75 1.17829626e-01 -7.24322708e-01 7.33844129e-01 -1.40953335 0.28457888 277.00 -1.54714878e-01 -7.55424989e-01 7.71105445e-01 -1.77280786 0.31930287 277.25 -6.22424873e-01 -4.95540363e-01 7.95595987e-01 -2.46920683 0.38765487 277.50 -5.45921424e-01 -4.03418016e-01 6.78805050e-01 -2.50519002 0.40977054 277.75 -4.57183420e-01 -3.75251430e-01 5.91464551e-01 -2.45430301 0.37230709 278.00 -4.43915162e-01 -2.44466078e-01 5.06778388e-01 -2.63820872 0.38444173 278.25 -3.85259104e-01 -2.64141310e-01 4.67113701e-01 -2.54058310 0.49294966 278.50 -3.90556423e-01 -2.50223108e-01 4.63838251e-01 -2.57179463 0.50318972 278.75 -3.75971542e-01 -2.22073749e-01 4.36659307e-01 -2.60806438 0.64849520 279.00 -3.60452779e-01 -1.91420930e-01 4.08127649e-01 -2.65340932 0.65992820 279.25 -3.08546002e-01 -1.36698984e-01 3.37471847e-01 -2.72453965 0.67262899 279.50 -2.88489806e-01 -9.93557795e-02 3.05119549e-01 -2.80991572 0.61425579 279.75 -2.24340810e-01 -1.01244912e-01 2.46128688e-01 -2.71765853 0.58107978 280.00 -1.85806520e-01 -1.10377979e-01 2.16118859e-01 -2.60556117 0.47261956 280.25 -1.71104208e-01 -1.22653281e-01 2.10524292e-01 -2.51965795 0.56885061 280.50 -1.58895605e-01 -1.07133844e-01 1.91638915e-01 -2.54836498 0.45593622 280.75 -1.51250011e-01 -8.79847289e-02 1.74979651e-01 -2.61472489 0.53558722 281.00 -1.41251365e-01 -9.77936384e-02 1.71800884e-01 -2.53602774 0.47538916 281.25 -1.44539945e-01 -8.99569715e-02 1.70247034e-01 -2.58488858 0.57778790 281.50 -1.32979703e-01 -8.72562911e-02 1.59051130e-01 -2.56089748 0.46728935 281.75 -1.16718189e-01 -6.66070771e-02 1.34386154e-01 -2.62302175 0.44478348 282.00 -1.16562449e-01 -4.98348326e-02 1.26768746e-01 -2.73757458 0.39176322 282.25 -1.04308256e-01 -4.07909015e-02 1.12000491e-01 -2.76881590 0.40469861 282.50 -7.62204008e-02 -5.36351414e-02 9.32002033e-02 -2.52839791 0.29351559 282.75 -6.85631075e-02 -5.00804836e-02 8.49055626e-02 -2.51073508 0.30757567 283.00 -5.66652934e-02 -4.92946818e-02 7.51060659e-02 -2.42564296 0.22146603 283.25 -7.45391234e-02 -5.35317446e-02 9.17699765e-02 -2.51877602 0.31642777 283.50 -5.76727733e-02 -4.95707231e-02 7.60487039e-02 -2.43159942 0.21469187 283.75 -4.79704515e-02 -4.84104079e-02 6.81522693e-02 -2.35162975 0.21822935 284.00 -4.68723777e-02 -5.34304633e-02 7.10762562e-02 -2.29090457 0.24484449 284.25 -5.41434790e-02 -6.11553377e-02 8.16791996e-02 -2.29545463 0.34316688 284.50 -4.96452825e-02 -5.87900636e-02 7.69475513e-02 -2.27205963 0.20900138 284.75 -5.37123066e-02 -6.86738567e-02 8.71843477e-02 -2.23454937 0.23600909 285.00 -3.95522877e-02 -5.25189639e-02 6.57466731e-02 -2.21628159 0.21401692 285.25 -4.52229071e-02 -5.23998702e-02 6.92160222e-02 -2.28280921 0.27538791 285.50 -6.64588800e-02 -5.79011197e-02 8.81437598e-02 -2.42490059 0.45295198 285.75 -6.41695537e-02 -5.13536165e-02 8.21883541e-02 -2.46668095 0.47215787 286.00 -4.61355471e-02 -3.80425816e-02 5.97973806e-02 -2.45204086 0.32365308 286.25 -5.22587143e-02 -2.65696852e-02 5.86252624e-02 -2.67122705 0.33991219 286.50 -4.38686884e-02 -4.50161159e-02 6.28562846e-02 -2.34328605 0.32899719 286.75 -3.40838270e-02 -3.90606324e-02 5.18405272e-02 -2.28825843 0.24719393 287.00 -5.00185832e-02 -2.88979552e-02 5.77663438e-02 -2.61769835 0.46831893 287.25 -4.88855756e-02 -3.12217054e-02 5.80051238e-02 -2.57322422 0.49213547 287.50 -4.08022964e-02 -2.47675599e-02 4.77311158e-02 -2.59603185 0.37385953 287.75 -3.11177835e-02 -2.76500184e-02 4.16273944e-02 -2.41513405 0.28004224 288.00 -2.95172231e-02 -2.26183394e-02 3.71867683e-02 -2.48775603 0.23608099 288.25 -2.90156620e-02 -2.84747582e-02 4.06536653e-02 -2.36560280 0.28083185 288.50 -2.67322483e-02 -2.79431943e-02 3.86708573e-02 -2.33405022 0.31138138 288.75 -2.53924608e-02 -2.68120619e-02 3.69278178e-02 -2.32900812 0.23890284 289.00 -3.80769273e-02 -2.32956829e-02 4.46378902e-02 -2.59253765 0.29037969 289.25 -3.41202883e-02 -2.06411108e-02 3.98779329e-02 -2.59754048 0.18622309 289.50 -3.66079032e-02 -1.39525737e-02 3.91766881e-02 -2.77745374 0.22760323 289.75 -2.57131893e-02 -1.73131242e-02 3.09985866e-02 -2.54900018 0.13693615 290.00 -2.34057901e-02 -2.76669055e-02 3.62393249e-02 -2.27295492 0.26959988 290.25 -2.35761075e-02 -2.81052454e-02 3.66842973e-02 -2.26878199 0.24788271 290.50 -2.16088305e-02 -2.93177017e-02 3.64207247e-02 -2.20596262 0.29366099 290.75 -2.13324093e-02 -2.89381506e-02 3.59511926e-02 -2.20603717 0.22012139 291.00 -2.63905477e-02 -2.98387432e-02 3.98348040e-02 -2.29494736 0.32873885 291.25 -3.25753672e-02 -3.57270786e-02 4.83485128e-02 -2.31008373 0.36659197 291.50 -2.94636634e-02 -4.11463390e-02 5.06075951e-02 -2.19222637 0.39101335 291.75 -4.04978433e-02 -3.53136495e-02 5.37320124e-02 -2.42447089 0.38141987 292.00 -4.85393645e-02 -3.84949417e-02 6.19510326e-02 -2.47109381 0.51311808 292.25 -4.43098486e-02 -3.98908233e-02 5.96208057e-02 -2.40862845 0.36160687 292.50 -5.13233935e-02 -3.23841035e-02 6.06862496e-02 -2.57870371 0.38579446 292.75 -5.95236323e-02 -2.49693016e-02 6.45486547e-02 -2.74440208 0.28079390 293.00 -5.91194664e-02 -2.02395685e-02 6.24880103e-02 -2.81174888 0.41127310 293.25 -5.68913731e-02 -1.90396993e-02 5.99928203e-02 -2.81864174 0.38437810 293.50 -5.33237168e-02 -1.90887414e-02 5.66374330e-02 -2.79782784 0.38407060 293.75 -5.83864258e-02 -1.23606717e-02 5.96804904e-02 -2.93296847 0.31905878 294.00 -6.13323402e-02 -1.17862383e-02 6.24545544e-02 -2.95173711 0.39221410 294.25 -5.90276560e-02 -1.00606619e-02 5.98788868e-02 -2.97277508 0.30553385 294.50 -5.26749304e-02 -2.70042424e-03 5.27441048e-02 -3.09037166 0.26746994 294.75 -5.79764323e-02 -9.73235685e-03 5.87876302e-02 -2.97527586 0.26273905 295.00 -4.65158694e-02 -4.35863242e-03 4.67196295e-02 -3.04816340 0.22152391 295.25 -4.56159537e-02 4.91373750e-03 4.58798436e-02 3.03428671 0.11997595 295.50 -5.25856152e-02 1.43861558e-03 5.26052900e-02 3.11424189 0.13007252 295.75 -3.67607721e-02 1.69329345e-02 4.04731841e-02 2.70993810 0.05734579 296.00 -3.95560073e-02 1.11543612e-02 4.10986312e-02 2.86674045 0.05046539 296.25 -3.21750952e-02 6.19927823e-03 3.27668705e-02 2.95125193 0.03136484 296.50 -3.95443525e-02 5.57922556e-03 3.99359935e-02 3.00142999 0.05618571 296.75 -2.93878199e-02 1.24696834e-02 3.19239246e-02 2.74030262 0.05415496 297.00 -2.00850384e-02 1.39865483e-02 2.44751364e-02 2.53330943 0.02916812 297.25 -3.65464254e-02 -5.76784065e-03 3.69987729e-02 -2.98506146 0.06064002 297.50 -3.43633194e-02 -1.19900582e-02 3.63950438e-02 -2.80588007 0.06432492 297.75 -3.00267607e-02 -4.33869693e-02 5.27639599e-02 -2.17617937 0.13447745 298.00 -3.20279054e-02 -3.57755948e-02 4.80174958e-02 -2.30097787 0.10128195 298.25 -6.45337049e-02 -2.46477594e-02 6.90804684e-02 -2.77675482 0.18788146 298.50 -5.89580383e-02 -4.09452935e-02 7.17813857e-02 -2.53457969 0.17074234 298.75 -8.54224408e-02 -3.85451632e-02 9.37161832e-02 -2.71771638 0.29132447 299.00 -9.33860573e-02 -3.93427045e-02 1.01335108e-01 -2.74286776 0.27671591 299.25 -8.32085928e-02 -2.70896330e-02 8.75072462e-02 -2.82685169 0.24012612 299.50 -8.06866490e-02 -6.37463364e-03 8.09380706e-02 -3.06275160 0.16217299 299.75 -7.63098179e-02 7.49854331e-03 7.66773530e-02 3.04364265 0.12833161 300.00 -6.66532696e-02 7.61347417e-03 6.70866852e-02 3.02786051 0.08716550 300.25 -8.41793319e-02 7.34040135e-03 8.44987658e-02 3.05461310 0.15450600 300.50 -8.74565476e-02 2.41773457e-02 9.07369372e-02 2.87187907 0.18856877 300.75 -6.34583927e-02 4.71374439e-02 7.90500235e-02 2.50270991 0.18708910 301.00 -7.80217798e-02 3.81555597e-02 8.68518558e-02 2.68675361 0.18269701 301.25 -9.61418578e-02 1.45865106e-02 9.72420851e-02 2.99102232 0.21868715 301.50 -1.10989557e-01 1.38433416e-02 1.11849541e-01 3.01750694 0.28585458 301.75 -1.20278132e-01 1.33922400e-02 1.21021408e-01 3.03070546 0.33589255 302.00 -1.17976447e-01 1.29510256e-02 1.18685176e-01 3.03225409 0.25764549 302.25 -1.20074638e-01 4.90486492e-03 1.20174774e-01 3.10076688 0.28303932 302.50 -1.00253162e-01 1.27249475e-02 1.01057512e-01 3.01533963 0.13991451 302.75 -7.93895692e-02 2.72608020e-02 8.39395915e-02 2.81082738 0.13207636 303.00 -7.27736253e-02 2.04781607e-02 7.55999709e-02 2.86729050 0.06635129 303.25 -1.03569840e-01 1.50173440e-02 1.04652914e-01 2.99759891 0.14865149 303.50 -1.35897998e-01 4.76540207e-02 1.44011012e-01 2.80432979 0.17975715 303.75 -1.66109276e-01 6.85670004e-02 1.79704549e-01 2.75011569 0.29255624 304.00 -1.86297162e-01 1.52500189e-02 1.86920293e-01 3.05991619 0.26165789 304.25 -1.78452073e-01 -1.04194961e-02 1.78756002e-01 -3.08327067 0.32085534 304.50 -1.95970804e-01 5.38345685e-02 2.03230698e-01 2.87349878 0.27855224 304.75 -2.35013641e-01 8.72152605e-02 2.50674915e-01 2.78623919 0.39719014 305.00 -2.09350930e-01 1.36718433e-01 2.50039480e-01 2.56307025 0.29090051 305.25 -2.14506748e-01 1.75053652e-01 2.76869872e-01 2.45712629 0.32551047 305.50 -1.82161331e-01 1.62420311e-01 2.44055542e-01 2.41342175 0.19676421 305.75 -1.35393448e-01 1.92947458e-01 2.35711916e-01 2.18267002 0.15791563 306.00 6.85938013e-04 2.55486694e-01 2.55487615e-01 1.56811150 0.13676523 306.25 3.45038161e-02 3.31546128e-01 3.33336690e-01 1.46710018 0.24768315 306.50 1.14988388e-01 2.51395831e-01 2.76445642e-01 1.14180584 0.20716556 306.75 1.50688380e-01 1.83309600e-01 2.37296012e-01 0.88275828 0.23529119 307.00 1.15448084e-01 1.48151340e-01 1.87821936e-01 0.90883167 0.22801813 307.25 1.09485004e-01 1.62863500e-01 1.96243435e-01 0.97893822 0.24329852 307.50 9.63926782e-02 2.03670771e-01 2.25329384e-01 1.12875480 0.37760050 307.75 1.00646527e-01 2.02345856e-01 2.25994621e-01 1.10923208 0.41515297 308.00 6.22281885e-02 1.73903248e-01 1.84701617e-01 1.22716112 0.39051084 308.25 6.26369374e-02 1.75638218e-01 1.86472973e-01 1.22823195 0.41975193 308.50 8.57606642e-02 1.75955656e-01 1.95742904e-01 1.11728000 0.48858113 308.75 7.39200840e-02 1.66359402e-01 1.82042933e-01 1.15265948 0.44439487 309.00 7.55404634e-02 1.53132404e-01 1.70750973e-01 1.11252176 0.43398728 309.25 6.06981007e-02 1.51634490e-01 1.63331803e-01 1.19003810 0.41981581 309.50 8.48560034e-02 1.30375961e-01 1.55558454e-01 0.99381944 0.43665862 309.75 8.09174810e-02 1.13179587e-01 1.39130362e-01 0.95010866 0.31221634 310.00 7.39989030e-02 1.83668290e-01 1.98014844e-01 1.18779738 0.47783931 310.25 5.70983570e-02 1.52048932e-01 1.62416440e-01 1.21156441 0.32559931 310.50 1.79516597e-03 1.28879199e-01 1.28891701e-01 1.55686817 0.28479212 310.75 -3.26224522e-02 1.61702897e-01 1.64960756e-01 1.76986743 0.31036762 311.00 -9.95277132e-02 2.21881215e-01 2.43181083e-01 1.99245464 0.48953307 311.25 -1.14964549e-01 2.63994036e-01 2.87940443e-01 1.98151139 0.51831947 311.50 -8.50157547e-02 3.52028334e-01 3.62148625e-01 1.80776158 0.61742605 311.75 -9.26625406e-02 4.08989983e-01 4.19355640e-01 1.79359922 0.59073778 312.00 -6.05205910e-02 4.96518748e-01 5.00193572e-01 1.69208785 0.69695348 312.25 -6.12247981e-02 5.24546249e-01 5.28107228e-01 1.68699012 0.62006211 312.50 -6.36592745e-02 5.42673736e-01 5.46394809e-01 1.68756936 0.49860410 312.75 -2.46583814e-03 4.63351815e-01 4.63358376e-01 1.57611802 0.20152292 313.00 3.31642315e-01 3.84372902e-01 5.07670319e-01 0.85890996 0.16009901 313.25 1.03539607e-01 3.59802753e-02 1.09613094e-01 0.33444817 0.00938313 313.50 1.51188442e-01 -1.99620564e-01 2.50412289e-01 -0.92258930 0.04876750 313.75 7.27613550e-02 -4.94000353e-01 4.99330114e-01 -1.42455771 0.29356942 314.00 5.04031059e-02 -5.95398799e-01 5.97528411e-01 -1.48634332 0.52499533 314.25 3.03490586e-02 -4.69523286e-01 4.70503116e-01 -1.50624810 0.62017258 314.50 5.06903027e-02 -4.25671117e-01 4.28678675e-01 -1.45227123 0.72976700 314.75 7.64144540e-02 -3.31592425e-01 3.40283272e-01 -1.34430351 0.70426889 315.00 9.42510539e-02 -3.15594890e-01 3.29368177e-01 -1.28058248 0.76206015 315.25 1.19767641e-01 -3.00564310e-01 3.23547820e-01 -1.19160450 0.69280108 315.50 1.09929259e-01 -2.91642027e-01 3.11672126e-01 -1.21033279 0.69510011 315.75 4.31965433e-02 -2.45724085e-01 2.49492019e-01 -1.39678145 0.52854414 316.00 4.94251797e-03 -2.29306758e-01 2.29360018e-01 -1.54924549 0.51990265 316.25 3.13112259e-02 -1.53953683e-01 1.57105472e-01 -1.37015210 0.41821674 316.50 3.27596159e-02 -1.53214743e-01 1.56677853e-01 -1.36015305 0.50480078 316.75 7.09539497e-02 -1.56396751e-01 1.71739357e-01 -1.14488701 0.54787355 317.00 7.92331843e-02 -1.54220749e-01 1.73383785e-01 -1.09619766 0.56374977 317.25 6.75289159e-02 -1.69182976e-01 1.82162109e-01 -1.19102531 0.61165315 317.50 6.04549062e-02 -1.67181801e-01 1.77776686e-01 -1.22381463 0.61780419 317.75 9.04851222e-02 -2.02311087e-01 2.21624307e-01 -1.15022552 0.65389993 318.00 7.02840869e-02 -2.14698208e-01 2.25909657e-01 -1.25442935 0.67027829 318.25 4.42510597e-02 -2.04320341e-01 2.09057308e-01 -1.35751346 0.63513986 318.50 2.88325506e-02 -2.20538408e-01 2.22415164e-01 -1.44079655 0.65781635 318.75 -4.93241421e-03 -2.04180068e-01 2.04239636e-01 -1.59494881 0.67756360 319.00 -1.61679225e-02 -2.06740336e-01 2.07371571e-01 -1.64884149 0.61324291 319.25 -7.22688205e-02 -1.85082084e-01 1.98691117e-01 -1.94305944 0.66601427 319.50 -9.09126485e-02 -1.82394095e-01 2.03795770e-01 -2.03319575 0.63845418 319.75 -8.43831924e-02 -1.41105854e-01 1.64412241e-01 -2.10975382 0.60128657 320.00 -9.72000715e-02 -1.31152184e-01 1.63244446e-01 -2.20859275 0.60414907 320.25 -7.73635866e-02 -1.17588756e-01 1.40755959e-01 -2.15271666 0.65655459 320.50 -7.35486458e-02 -1.12612528e-01 1.34502731e-01 -2.14935646 0.61443310 320.75 -9.29476982e-02 -1.18906626e-01 1.50924021e-01 -2.23427029 0.69900074 321.00 -1.13175901e-01 -9.77452141e-02 1.49542340e-01 -2.42922296 0.64765907 321.25 -1.25227737e-01 -7.18982592e-02 1.44399951e-01 -2.62040489 0.68998258 321.50 -1.13769326e-01 -4.93233808e-02 1.24001030e-01 -2.73251212 0.54575229 321.75 -9.83256151e-02 -4.61507397e-02 1.08617758e-01 -2.70275086 0.57540687 322.00 -8.54386923e-02 -3.09402256e-02 9.08684087e-02 -2.79414950 0.44058916 322.25 -6.38441964e-02 -5.29187674e-03 6.40631358e-02 -3.05889434 0.37856771 322.50 -6.27107846e-02 -4.79584322e-03 6.28938997e-02 -3.06526565 0.32098037 322.75 -5.70244458e-02 -1.62135515e-02 5.92846242e-02 -2.86457667 0.32692609 323.00 -4.84470091e-02 -2.14543543e-02 5.29849225e-02 -2.72470752 0.26024595 323.25 -5.09877599e-02 -2.32767478e-02 5.60496088e-02 -2.71333293 0.32308717 323.50 -5.19097899e-02 -2.95577096e-02 5.97351193e-02 -2.62397310 0.34081751 323.75 -4.19440153e-02 -2.13318962e-02 4.70568827e-02 -2.67110446 0.29475776 324.00 -3.87937196e-02 -1.99212615e-02 4.36097390e-02 -2.66718946 0.20061989 324.25 -3.24793397e-02 -1.53979268e-02 3.59444524e-02 -2.69889217 0.15556264 324.50 -3.59851872e-02 -2.54412876e-02 4.40703167e-02 -2.52618858 0.20679829 324.75 -4.14119493e-02 -3.52300241e-02 5.43700666e-02 -2.43668003 0.39132134 325.00 -3.59309322e-02 -1.63089537e-02 3.94590150e-02 -2.71550245 0.20067559 325.25 -4.22376036e-02 -1.93647653e-02 4.64651407e-02 -2.71171566 0.33025654 325.50 -3.40127997e-02 -1.44567077e-02 3.69576371e-02 -2.73969043 0.22127304 325.75 -3.19377104e-02 -1.17080992e-02 3.40161276e-02 -2.79021395 0.22633162 326.00 -3.11727864e-02 -1.91891966e-02 3.66055717e-02 -2.58979939 0.28901891 326.25 -3.30494751e-02 -1.99017585e-02 3.85791109e-02 -2.59957118 0.33911181 326.50 -3.36620371e-02 -1.36590521e-02 3.63277091e-02 -2.75612187 0.22693437 326.75 -3.16640757e-02 -5.67185468e-03 3.21680528e-02 -2.96434655 0.21972325 327.00 -1.06995748e-02 -5.61633496e-03 1.20840440e-02 -2.65821466 0.04190259 327.25 -3.95544978e-03 -5.42472551e-03 6.71365994e-03 -2.20082070 0.01218805 327.50 -8.39894456e-03 -2.33711538e-02 2.48345143e-02 -1.91579609 0.10283121 327.75 -9.33809258e-03 -2.71074308e-02 2.86707653e-02 -1.90254923 0.11524321 328.00 -1.67113117e-02 -3.74735096e-02 4.10308647e-02 -1.99027717 0.24479658 328.25 -1.83832062e-02 -4.04889751e-02 4.44668346e-02 -1.99699648 0.28458107 328.50 -2.90934769e-03 -1.21971783e-02 1.25393565e-02 -1.80494740 0.02615448 328.75 -5.78827479e-04 -8.70185172e-03 8.72108162e-03 -1.63721622 0.01077682 329.00 5.27302294e-03 -4.01141674e-02 4.04592535e-02 -1.44009530 0.19662345 329.25 5.20206690e-03 -4.66341790e-02 4.69234286e-02 -1.45970508 0.27997652 329.50 -6.33634973e-04 -5.57142106e-02 5.57178136e-02 -1.58216879 0.39983111 329.75 -1.73164298e-02 -6.13882455e-02 6.37838180e-02 -1.84573328 0.41482597 330.00 -3.04616605e-02 -8.79900478e-02 9.31137008e-02 -1.90407683 0.60105716 330.25 -4.45476607e-02 -7.92709064e-02 9.09305817e-02 -2.08278107 0.56858918 330.50 -5.49819801e-02 -4.52112219e-02 7.11833739e-02 -2.45340628 0.49925979 330.75 -5.46637107e-02 -4.46003296e-02 7.05500579e-02 -2.45722922 0.47895023 331.00 -3.71813359e-02 -3.33774631e-02 4.99650556e-02 -2.41005303 0.36568528 331.25 -3.64626236e-02 -3.17902231e-02 4.83750060e-02 -2.42454508 0.32065908 331.50 -4.33112311e-02 -2.77497805e-02 5.14384395e-02 -2.57177853 0.41088626 331.75 -4.24855401e-02 -2.83876302e-02 5.10967578e-02 -2.55254891 0.37068695 332.00 -3.76251838e-02 -3.29767969e-02 5.00312262e-02 -2.42193893 0.48957563 332.25 -3.50717599e-02 -2.70510115e-02 4.42920486e-02 -2.48459541 0.35507372 332.50 -2.52645414e-02 -2.19779635e-02 3.34862350e-02 -2.42565082 0.27819517 332.75 -2.96309912e-02 -1.78221026e-02 3.45777816e-02 -2.60009420 0.23324593 333.00 -2.32769872e-02 -1.42140690e-02 2.72737583e-02 -2.59337978 0.14543553 333.25 -2.72116238e-02 -3.01183100e-02 4.05904554e-02 -2.30553685 0.21667826 333.50 -4.12366842e-02 -3.34329831e-02 5.30869898e-02 -2.46032612 0.31302083 333.75 -3.09934330e-02 -8.49405136e-03 3.21363003e-02 -2.87410083 0.12292405 334.00 -8.76085695e-03 5.01374113e-03 1.00940683e-02 2.62179823 0.01752798 334.25 1.70918519e-02 -3.72284215e-03 1.74925972e-02 -0.21446413 0.04934643 334.50 3.92800268e-02 -3.02565390e-02 4.95820396e-02 -0.65635320 0.32484378 334.75 4.45062798e-02 -6.44437208e-02 7.83185936e-02 -0.96639179 0.47684331 335.00 2.92287298e-02 -9.50825505e-02 9.94736651e-02 -1.27256105 0.64271446 335.25 1.86675794e-02 -9.26438496e-02 9.45058802e-02 -1.37196050 0.50021709 335.50 7.27531979e-03 -1.01809748e-01 1.02069364e-01 -1.49945764 0.49786561 335.75 1.78098096e-03 -1.07692367e-01 1.07707093e-01 -1.55426016 0.58268165 336.00 8.15189651e-04 -1.10100543e-01 1.10103561e-01 -1.56339241 0.64880550 336.25 -3.70424403e-03 -1.34747691e-01 1.34798596e-01 -1.59827963 0.75859183 336.50 -7.79270157e-03 -1.53317587e-01 1.53515500e-01 -1.62157981 0.82342356 336.75 -3.51483395e-02 -1.58479400e-01 1.62330299e-01 -1.78904850 0.80116484 337.00 -5.60148526e-02 -1.66618793e-01 1.75782496e-01 -1.89511179 0.80226131 337.25 -1.33626510e-01 -1.56732488e-01 2.05963873e-01 -2.27678455 0.80923587 337.50 -1.55964868e-01 -1.31545857e-01 2.04032724e-01 -2.44092367 0.83893693 337.75 -1.50249882e-01 -8.53244421e-02 1.72786827e-01 -2.62512299 0.82805444 338.00 -1.67813046e-01 -6.99050421e-02 1.81790905e-01 -2.74688816 0.85668917 338.25 -1.63418809e-01 -4.90355306e-02 1.70617087e-01 -2.85008035 0.79459138 338.50 -1.46161552e-01 -2.51924809e-02 1.48316757e-01 -2.97090918 0.76306708 338.75 -1.45057904e-01 -3.34996863e-02 1.48875870e-01 -2.91463159 0.74340832 339.00 -1.35474546e-01 -2.03095984e-02 1.36988439e-01 -2.99278633 0.64888433 339.25 -1.25522188e-01 -3.42749993e-04 1.25522656e-01 -3.13886207 0.64143560 339.50 -1.15062529e-01 1.37119084e-02 1.15876667e-01 3.02298282 0.61194765 339.75 -1.10474926e-01 5.57288712e-03 1.10615399e-01 3.09119056 0.67372805 340.00 -1.04496522e-01 1.75631753e-02 1.05962201e-01 2.97507474 0.67655016 340.25 -8.98840665e-02 3.59628120e-02 9.68115141e-02 2.76099818 0.61566559 340.50 -8.19996488e-02 4.08789995e-02 9.16244236e-02 2.67912452 0.54168361 340.75 -8.34822981e-02 4.71974585e-02 9.59004389e-02 2.62703412 0.60761798 341.00 -6.80241676e-02 5.89469887e-02 9.00113040e-02 2.42756316 0.52943401 341.25 -4.68616352e-02 7.20470453e-02 8.59464344e-02 2.14747451 0.53445263 341.50 -2.17612487e-02 7.59729240e-02 7.90280781e-02 1.84976150 0.34730062 341.75 3.65638827e-02 8.82107212e-02 9.54884750e-02 1.17784757 0.44449574 342.00 5.77683463e-02 7.08665325e-02 9.14289192e-02 0.88687295 0.32949256 342.25 8.99985909e-02 3.60967922e-02 9.69676480e-02 0.38143857 0.37291658 342.50 1.16859545e-01 2.07165771e-02 1.18681632e-01 0.17545471 0.43041429 342.75 1.40882224e-01 7.72249787e-03 1.41093721e-01 0.05476047 0.54841275 343.00 1.57491563e-01 -2.76880007e-02 1.59906904e-01 -0.17402785 0.53626042 343.25 1.71698110e-01 -5.13127765e-02 1.79201680e-01 -0.29040567 0.70815934 343.50 1.80246227e-01 -6.36366752e-02 1.91150016e-01 -0.33939305 0.67505689 343.75 2.07762805e-01 -8.39334143e-02 2.24076329e-01 -0.38393847 0.79295946 344.00 2.60894481e-01 -1.07936258e-01 2.82340514e-01 -0.39227443 0.76330454 344.25 3.22211903e-01 -1.53314058e-01 3.56827284e-01 -0.44411512 0.83179745 344.50 3.76583663e-01 -2.12670124e-01 4.32485649e-01 -0.51408594 0.82458179 344.75 4.58803584e-01 -2.95274869e-01 5.45607896e-01 -0.57184580 0.86766648 345.00 5.12463817e-01 -4.40495615e-01 6.75762940e-01 -0.71002051 0.87662358 345.25 5.64881298e-01 -5.43372360e-01 7.83801252e-01 -0.76599264 0.89374713 345.50 5.12749618e-01 -8.34416679e-01 9.79368860e-01 -1.01978273 0.84444451 345.75 4.39326146e-01 -1.04971254e+00 1.13793844e+00 -1.17442671 0.89105479 346.00 1.44826602e-01 -1.34598119e+00 1.35375039e+00 -1.46360944 0.88691136 346.25 -9.98305837e-02 -1.44021007e+00 1.44366589e+00 -1.64000231 0.90824659 346.50 -5.79161988e-01 -1.42626823e+00 1.53937314e+00 -1.95652283 0.90209337 346.75 -8.47641473e-01 -1.29645324e+00 1.54896323e+00 -2.14984926 0.92635455 347.00 -1.02956928e+00 -1.06250331e+00 1.47950201e+00 -2.34045349 0.93813861 347.25 -1.08097705e+00 -9.22229328e-01 1.42092165e+00 -2.43527604 0.94795304 347.50 -1.22513121e+00 -7.28942340e-01 1.42558880e+00 -2.60486420 0.94833329 347.75 -1.28570568e+00 -6.24048450e-01 1.42915204e+00 -2.68971394 0.94862203 348.00 -1.31745797e+00 -4.47568518e-01 1.39140687e+00 -2.81410400 0.90367429 348.25 -1.31587940e+00 -2.32954470e-01 1.33634067e+00 -2.96637479 0.92896530 348.50 -1.35304536e+00 -6.56892704e-02 1.35463900e+00 -3.09308154 0.95291266 348.75 -1.34526642e+00 -1.74101786e-03 1.34526754e+00 -3.14029847 0.96202518 349.00 -1.29862217e+00 1.39615178e-01 1.30610564e+00 3.03449378 0.95628932 349.25 -1.22201391e+00 2.53919666e-01 1.24811585e+00 2.93672010 0.93991347 349.50 -1.15571581e+00 4.16793915e-01 1.22857486e+00 2.79547325 0.95093586 349.75 -1.11276784e+00 4.84376234e-01 1.21361963e+00 2.73103903 0.95427858 350.00 -1.07570471e+00 5.74424625e-01 1.21946885e+00 2.65111766 0.92769559 350.25 -9.88763847e-01 6.21984699e-01 1.16812624e+00 2.58008425 0.91635120 350.50 -8.13102705e-01 7.21167634e-01 1.08683889e+00 2.41604397 0.95139045 350.75 -7.47665095e-01 7.59071834e-01 1.06545443e+00 2.34862414 0.95541940 351.00 -6.12224742e-01 7.52809099e-01 9.70330188e-01 2.25356667 0.95072581 351.25 -5.16847148e-01 7.65300262e-01 9.23480083e-01 2.16478785 0.92580197 351.50 -3.72729533e-01 7.64346066e-01 8.50383568e-01 2.02451117 0.94090900 351.75 -2.91967886e-01 7.32920175e-01 7.88934237e-01 1.94989024 0.91381562 352.00 -1.94082116e-01 6.87735198e-01 7.14596089e-01 1.84584829 0.91238868 352.25 -9.85709288e-02 6.23762280e-01 6.31502660e-01 1.72752670 0.85553285 352.50 2.09389950e-02 5.06706769e-01 5.07139223e-01 1.52949613 0.82950536 352.75 2.26782828e-02 3.85616466e-01 3.86282750e-01 1.51205353 0.72041259 353.00 -3.82076425e-03 2.65435890e-01 2.65463387e-01 1.58518963 0.65623883 353.25 -1.10724610e-02 1.84102847e-01 1.84435511e-01 1.63086677 0.46207264 353.50 -1.12784544e-02 1.26024627e-01 1.26528297e-01 1.66005259 0.38005749 353.75 -1.96461024e-02 8.53807297e-02 8.76118619e-02 1.79695965 0.16985693 354.00 -6.29086507e-02 -5.25452497e-03 6.31277147e-02 -3.05825982 0.08645426 354.25 -1.18102346e-01 -1.20675396e-01 1.68851163e-01 -2.34541899 0.25839344 354.50 -1.92696186e-01 -2.46980807e-01 3.13259221e-01 -2.23335139 0.56811984 354.75 -3.35953614e-01 -4.88966679e-01 5.93256474e-01 -2.17279062 0.69248583 355.00 -6.46767323e-01 -6.72666833e-01 9.33160565e-01 -2.33656776 0.81253473 355.25 -1.10101693e+00 -6.60451151e-01 1.28391355e+00 -2.60127935 0.81219954 355.50 -1.57413395e+00 -5.61835471e-01 1.67139367e+00 -2.79876886 0.84241087 355.75 -1.95855986e+00 2.03658621e-01 1.96911999e+00 3.03798116 0.70064756 356.00 -2.43705457e+00 1.27110478e+00 2.74862554e+00 2.66083502 0.79271818 356.25 -1.63421906e+00 2.40217671e+00 2.90536140e+00 2.16818329 0.75986301 356.50 -7.74577892e-01 2.98449892e+00 3.08337554e+00 1.82472751 0.83045712 356.75 5.68488332e-01 2.48096243e+00 2.54526100e+00 1.34554465 0.76490227 357.00 1.13854464e+00 2.13788265e+00 2.42215320e+00 1.08144351 0.85394011 357.25 1.06591523e+00 1.09509392e+00 1.52820352e+00 0.79889969 0.81497085 357.50 9.85641475e-01 7.97296131e-01 1.26774218e+00 0.68015085 0.89566959 357.75 7.15208438e-01 6.55993670e-01 9.70489982e-01 0.74224041 0.88974484 358.00 6.23862969e-01 7.71154384e-01 9.91909314e-01 0.89059235 0.87848973 358.25 1.08427141e+00 7.73854242e-01 1.33210167e+00 0.61986749 0.81379582 358.50 1.21664881e+00 3.36756364e-01 1.26239422e+00 0.27002970 0.76608472 358.75 8.00304778e-01 -1.70629382e-01 8.18292199e-01 -0.21006032 0.83004634 359.00 6.49987943e-01 -2.19648730e-01 6.86097581e-01 -0.32587949 0.90380778 359.25 4.64789735e-01 -2.02931042e-01 5.07159251e-01 -0.41166173 0.92368586 359.50 3.86589303e-01 -1.80499657e-01 4.26651398e-01 -0.43682111 0.92711830 359.75 2.48472899e-01 -1.49983897e-01 2.90230858e-01 -0.54307904 0.88547530 360.00 1.97135215e-01 -1.15856829e-01 2.28659349e-01 -0.53132803 0.86128241 360.25 1.42326100e-01 -7.47701596e-02 1.60770941e-01 -0.48371662 0.84500148 360.50 1.16600373e-01 -6.90246148e-02 1.35499242e-01 -0.53449856 0.81741252 360.75 6.46154841e-02 -3.94707839e-02 7.57172607e-02 -0.54836395 0.59568397 361.00 4.00893496e-02 -1.88622095e-02 4.43050663e-02 -0.43977382 0.37862963 361.25 2.80964824e-02 2.74937812e-02 3.93105625e-02 0.77455674 0.33295443 361.50 2.85593555e-02 5.12906583e-02 5.87057783e-02 1.06273671 0.48724902 361.75 5.08894697e-02 6.35378301e-02 8.14051225e-02 0.89548746 0.73233994 362.00 4.49832425e-02 4.97076548e-02 6.70398617e-02 0.83524982 0.58349457 362.25 1.00245973e-02 3.95263138e-02 4.07777150e-02 1.32241510 0.45484868 362.50 -4.04033576e-04 5.41951159e-02 5.41966219e-02 1.57825135 0.57843620 362.75 -2.29764276e-02 7.28471927e-02 7.63847479e-02 1.87632628 0.77962826 363.00 -2.30332884e-02 8.52960516e-02 8.83512806e-02 1.83454482 0.78436565 363.25 -2.37964215e-02 1.06624615e-01 1.09247784e-01 1.79037726 0.88815404 363.50 -1.82946237e-02 1.17166587e-01 1.18586265e-01 1.72568763 0.89121068 363.75 -1.14308402e-02 1.29175092e-01 1.29679869e-01 1.65905748 0.91817068 364.00 1.65563749e-03 1.24275342e-01 1.24286370e-01 1.55747478 0.88808688 364.25 1.38356542e-02 1.18057191e-01 1.18865158e-01 1.45413398 0.91042804 364.50 8.75003667e-03 1.03780566e-01 1.04148783e-01 1.48668240 0.82353410 364.75 -7.30775361e-03 8.02831059e-02 8.06150133e-02 1.66157097 0.77969934 365.00 -2.97084630e-02 8.52280989e-02 9.02575294e-02 1.90620192 0.76949347 365.25 -3.59446493e-02 1.02921460e-01 1.09017635e-01 1.90679703 0.81382928 365.50 -1.43821289e-02 1.20328978e-01 1.21185431e-01 1.68975539 0.71989913 365.75 9.79763203e-03 1.19694260e-01 1.20094585e-01 1.48912293 0.75595885 366.00 1.10824039e-02 1.03422513e-01 1.04014595e-01 1.46404708 0.73242547 366.25 6.40109229e-03 9.09498792e-02 9.11748568e-02 1.50053175 0.75968193 366.50 -2.98436865e-03 9.61689874e-02 9.62152825e-02 1.60181892 0.74568403 366.75 -8.97068248e-03 9.33684941e-02 9.37984479e-02 1.66658058 0.83401255 367.00 -5.72998349e-03 9.20667853e-02 9.22449222e-02 1.63295340 0.82942091 367.25 -1.09350145e-03 8.85096286e-02 8.85163833e-02 1.58315030 0.84256023 367.50 -1.00357839e-02 8.50808723e-02 8.56707172e-02 1.68820960 0.80104500 367.75 -1.34453574e-02 7.65725705e-02 7.77440428e-02 1.74461415 0.81033181 368.00 -2.75805114e-02 6.78895538e-02 7.32780740e-02 1.95668380 0.75998749 368.25 -3.85047904e-02 6.98700818e-02 7.97774857e-02 2.07447696 0.79641964 368.50 -5.25488960e-02 8.06522264e-02 9.62609375e-02 2.14825987 0.84196333 368.75 -5.21051920e-02 8.76685275e-02 1.01983929e-01 2.10704602 0.86015999 369.00 -5.48988386e-02 9.83559071e-02 1.12639988e-01 2.07988674 0.80624495 369.25 -5.37338244e-02 1.04647899e-01 1.17637182e-01 2.04516380 0.81610387 369.50 -4.41987355e-02 1.05842179e-01 1.14700022e-01 1.96637474 0.83429426 369.75 -5.17272723e-02 1.11603541e-01 1.23008378e-01 2.00481282 0.86315615 370.00 -2.35594372e-02 1.17450909e-01 1.19790497e-01 1.76875880 0.86181844 370.25 -1.44932268e-02 1.09664647e-01 1.10618210e-01 1.70219437 0.88115602 370.50 -1.99205722e-02 9.59706302e-02 9.80162795e-02 1.77545951 0.90316882 370.75 -2.23969930e-02 9.83162454e-02 1.00835060e-01 1.79477959 0.89375617 371.00 -2.04489499e-02 9.75353761e-02 9.96559538e-02 1.77745975 0.89328716 371.25 -1.98405399e-02 9.44941798e-02 9.65546324e-02 1.77775570 0.86998406 371.50 -1.54732505e-02 8.05791296e-02 8.20513109e-02 1.76051251 0.82120507 371.75 -1.09139143e-02 8.00963063e-02 8.08364510e-02 1.70622219 0.80070434 372.00 -1.05910484e-02 7.32574944e-02 7.40191245e-02 1.71437442 0.74393585 372.25 -1.51369591e-02 6.40619514e-02 6.58259914e-02 1.80282688 0.65963589 372.50 -2.43069461e-02 6.03333667e-02 6.50456976e-02 1.95378070 0.71344508 372.75 -2.81268807e-02 5.62309009e-02 6.28731710e-02 2.03460654 0.64400222 373.00 -3.59755818e-02 4.15984155e-02 5.49970059e-02 2.28383754 0.53734744 373.25 -4.44838650e-02 3.35883889e-02 5.57404173e-02 2.49485525 0.58627952 373.50 -4.71070752e-02 3.73267010e-02 6.01029046e-02 2.47151540 0.74989148 373.75 -5.11077879e-02 4.32345536e-02 6.69420093e-02 2.43945543 0.80490391 374.00 -4.93460067e-02 5.08648709e-02 7.08679297e-02 2.34103897 0.84854099 374.25 -4.66732098e-02 4.52838235e-02 6.50308633e-02 2.37130242 0.84563684 374.50 -4.82080702e-02 3.93916210e-02 6.22552635e-02 2.45650147 0.89393954 374.75 -4.98195329e-02 2.12938737e-02 5.41794695e-02 2.73767388 0.82859469 375.00 -5.62378141e-02 1.12098224e-02 5.73441527e-02 2.94484245 0.86438631 375.25 -7.22349848e-02 6.68590743e-03 7.25437412e-02 3.04929787 0.83420627 375.50 -8.96291131e-02 3.70028775e-03 8.97054627e-02 3.10033164 0.88997986 375.75 -1.12119979e-01 1.05365085e-02 1.12613976e-01 3.04789254 0.87991656 376.00 -1.31110750e-01 2.74839036e-02 1.33960419e-01 2.93496102 0.92294098 376.25 -1.35087034e-01 6.89478317e-02 1.51665125e-01 2.66966317 0.91780028 376.50 -1.27415655e-01 8.67159490e-02 1.54124641e-01 2.54402270 0.95499244 376.75 -8.45723223e-02 8.11366132e-02 1.17199094e-01 2.37692492 0.85384049 377.00 -5.97884754e-02 5.61433445e-02 8.20166868e-02 2.38762616 0.80385915 377.25 -6.67476070e-02 2.20232746e-02 7.02870376e-02 2.82289151 0.77076532 377.50 -8.03197739e-02 8.36005355e-03 8.07536784e-02 3.03788147 0.84468760 377.75 -1.18163910e-01 1.41557383e-02 1.19008801e-01 3.02236338 0.92053128 378.00 -1.30256662e-01 2.06202632e-02 1.31878707e-01 2.98459065 0.94228190 378.25 -1.39637711e-01 2.20646227e-02 1.41370215e-01 2.98487505 0.94725938 378.50 -1.43335347e-01 2.62053721e-02 1.45711164e-01 2.96076414 0.96557873 378.75 -1.53052962e-01 3.32638160e-02 1.56625958e-01 2.92758542 0.95378245 379.00 -1.59463843e-01 3.90461132e-02 1.64174651e-01 2.90145866 0.95563542 379.25 -1.60833831e-01 6.69799238e-02 1.74223509e-01 2.74698259 0.94562949 379.50 -1.57562557e-01 7.96345322e-02 1.76543531e-01 2.67362217 0.95034250 379.75 -1.38611514e-01 8.79017012e-02 1.64133668e-01 2.57643438 0.92053324 380.00 -1.35761227e-01 9.17061630e-02 1.63832631e-01 2.54750233 0.93505602 380.25 -1.32901406e-01 7.97931004e-02 1.55015233e-01 2.60088409 0.94887639 380.50 -1.32135990e-01 7.60984079e-02 1.52482417e-01 2.61907492 0.94601514 380.75 -1.27102168e-01 7.17835311e-02 1.45972040e-01 2.62748024 0.91090467 381.00 -1.28799576e-01 6.98482060e-02 1.46519974e-01 2.64467919 0.90444154 381.25 -1.51169902e-01 7.55706608e-02 1.69006698e-01 2.67802067 0.93809107 381.50 -1.50294653e-01 8.18975760e-02 1.71159854e-01 2.64266306 0.93076034 381.75 -1.36632454e-01 9.76719432e-02 1.67953077e-01 2.52096849 0.90389473 382.00 -1.13152163e-01 1.00315764e-01 1.51217276e-01 2.41625485 0.85068466 382.25 -7.08729810e-02 1.04054117e-01 1.25897732e-01 2.16873609 0.81286864 382.50 -5.67113921e-02 9.42070471e-02 1.09959764e-01 2.11267538 0.69398166 382.75 -1.82627276e-02 4.06947958e-02 4.46048610e-02 1.99262945 0.21667003 383.00 -3.04077862e-02 -8.04249834e-03 3.14533821e-02 -2.88302527 0.11337763 383.25 -6.64596982e-02 -6.31010620e-02 9.16440697e-02 -2.38211194 0.65227177 383.50 -9.31727773e-02 -7.51652530e-02 1.19712078e-01 -2.46276164 0.74066654 383.75 -1.42731664e-01 -8.04136503e-02 1.63825160e-01 -2.62852706 0.87556442 384.00 -1.56095023e-01 -7.67728692e-02 1.73953240e-01 -2.68449901 0.88331435 384.25 -1.61023768e-01 -7.59199182e-02 1.78023840e-01 -2.70101804 0.92293386 384.50 -1.78322474e-01 -8.63277460e-02 1.98119621e-01 -2.69073742 0.91786582 384.75 -2.16192510e-01 -9.00421579e-02 2.34193919e-01 -2.74695153 0.95015707 385.00 -2.39827219e-01 -6.73800286e-02 2.49112752e-01 -2.86770102 0.94176617 385.25 -2.45750393e-01 -4.90818702e-02 2.50603842e-01 -2.94446398 0.96025680 385.50 -2.24346818e-01 -3.92113444e-02 2.27747720e-01 -2.96856042 0.92724801 385.75 -2.03433603e-01 -5.52845410e-02 2.10811791e-01 -2.87624376 0.92001107 386.00 -2.15352559e-01 -8.21027380e-02 2.30472524e-01 -2.77735555 0.92189561 386.25 -2.24373020e-01 -1.12622887e-01 2.51052120e-01 -2.67639036 0.92228495 386.50 -2.63933742e-01 -1.86468022e-01 3.23158387e-01 -2.52652053 0.90787913 386.75 -3.30346106e-01 -2.26123868e-01 4.00325559e-01 -2.54134126 0.94480438 387.00 -4.32248784e-01 -2.20973546e-01 4.85456815e-01 -2.66901063 0.94020854 387.25 -5.19500193e-01 -1.90456472e-01 5.53311953e-01 -2.79019356 0.96193972 387.50 -6.07198466e-01 -1.36150723e-01 6.22275660e-01 -2.92101341 0.96710189 387.75 -6.42929914e-01 -1.01273902e-01 6.50857341e-01 -2.98535705 0.97747221 388.00 -6.95954421e-01 -2.78553952e-02 6.96511651e-01 -3.10158927 0.95715155 388.25 -7.44959344e-01 4.68349889e-02 7.46430131e-01 3.07880610 0.96411063 388.50 -7.58989728e-01 1.55409580e-01 7.74737081e-01 2.93962585 0.96411073 388.75 -7.70594880e-01 2.05154271e-01 7.97436358e-01 2.88139944 0.96897758 389.00 -7.88939325e-01 3.45726725e-01 8.61366489e-01 2.72858045 0.96646477 389.25 -7.86279484e-01 4.07824911e-01 8.85751988e-01 2.66311550 0.97468925 389.50 -6.94907498e-01 5.60929896e-01 8.93050267e-01 2.46247637 0.96476702 389.75 -6.36884365e-01 6.40809202e-01 9.03470048e-01 2.35312269 0.96974721 390.00 -5.07531538e-01 7.04968692e-01 8.68659380e-01 2.19477648 0.96791806 390.25 -4.15457924e-01 7.26758231e-01 8.37127716e-01 2.09011617 0.96384300 390.50 -2.98123118e-01 7.15525327e-01 7.75147656e-01 1.96557264 0.96429048 390.75 -2.46254114e-01 6.83371732e-01 7.26386958e-01 1.91666315 0.96334426 391.00 -1.78456168e-01 6.39704928e-01 6.64130258e-01 1.84284630 0.94417703 391.25 -1.21908344e-01 5.98682693e-01 6.10968584e-01 1.77167756 0.94646914 391.50 -8.79611420e-02 5.36331897e-01 5.43497071e-01 1.73335421 0.93976342 391.75 -8.61026871e-02 4.99058290e-01 5.06431486e-01 1.74164470 0.93695966 392.00 -8.37956356e-02 4.59172863e-01 4.66756282e-01 1.75130256 0.93512021 392.25 -8.26174652e-02 4.48037599e-01 4.55591193e-01 1.75314644 0.92805840 392.50 -9.25021846e-02 4.94311851e-01 5.02892494e-01 1.75578996 0.93918779 392.75 -7.55974717e-02 5.01526235e-01 5.07191820e-01 1.72040486 0.93857465 393.00 -7.02699423e-03 4.97607055e-01 4.97656669e-01 1.58491696 0.94830198 393.25 1.62855867e-02 4.80260709e-01 4.80536751e-01 1.53689943 0.93751217 393.50 8.42270930e-02 4.08490331e-01 4.17083390e-01 1.36745488 0.91248916 393.75 9.73472879e-02 3.60037237e-01 3.72965557e-01 1.30672926 0.89469490 394.00 1.12493130e-01 2.85324769e-01 3.06700062e-01 1.19524501 0.88966207 394.25 9.14037863e-02 2.43574151e-01 2.60159604e-01 1.21179719 0.85924122 394.50 4.40925147e-02 2.01265332e-01 2.06038550e-01 1.35512701 0.72739066 394.75 5.83110970e-03 1.99151514e-01 1.99236862e-01 1.54152492 0.74875803 395.00 -4.39155249e-02 2.16373162e-01 2.20784779e-01 1.77103831 0.81299781 395.25 -4.14247454e-02 2.30308195e-01 2.34004004e-01 1.74876002 0.74799798 395.50 -5.77125604e-02 2.69576623e-01 2.75685138e-01 1.78169863 0.80693666 395.75 -3.09053848e-02 2.71762607e-01 2.73514272e-01 1.68403184 0.77101463 396.00 2.45779146e-02 2.25055823e-01 2.26393899e-01 1.46201932 0.71801730 396.25 1.76340674e-02 1.62964019e-01 1.63915319e-01 1.46300737 0.69567375 396.50 6.31019174e-03 1.34856077e-01 1.35003629e-01 1.52403839 0.74291505 396.75 -2.26127281e-02 1.12742305e-01 1.14987664e-01 1.76873994 0.62587666 397.00 -7.87565199e-02 1.04949581e-01 1.31213582e-01 2.21456774 0.65012250 397.25 -1.16626807e-01 1.43666265e-01 1.85045421e-01 2.25268493 0.74503979 397.50 -1.17818758e-01 1.79145874e-01 2.14416660e-01 2.15254416 0.85737177 397.75 -8.11567822e-02 2.18650088e-01 2.33225823e-01 1.92620669 0.86410127 398.00 -4.07116076e-02 2.17870917e-01 2.21641990e-01 1.75552704 0.90975897 398.25 -1.17698754e-02 1.74620899e-01 1.75017109e-01 1.63809698 0.85926404 398.50 -1.36754306e-02 1.39637714e-01 1.40305768e-01 1.66842009 0.85799014 398.75 -3.57772402e-02 1.12064655e-01 1.17637145e-01 1.87982364 0.84888273 399.00 -5.03739694e-02 1.01963617e-01 1.13728255e-01 2.02966351 0.88942881 399.25 -6.20719377e-02 9.99022546e-02 1.17615415e-01 2.12674980 0.88745218 399.50 -7.53917836e-02 9.50077187e-02 1.21286387e-01 2.24158167 0.87800399 399.75 -8.38951607e-02 7.81698114e-02 1.14668729e-01 2.39150730 0.88667939 400.00 -8.79748179e-02 7.99306028e-02 1.18863240e-01 2.40406709 0.89509516 400.25 -9.80051575e-02 7.62904002e-02 1.24198374e-01 2.48014167 0.89812898 400.50 -1.00819935e-01 6.67729154e-02 1.20926761e-01 2.55662010 0.88821302 400.75 -1.22474201e-01 5.79408105e-02 1.35488256e-01 2.69970726 0.85972278 401.00 -1.23279767e-01 4.10300464e-02 1.29928309e-01 2.82030363 0.81970203 401.25 -1.53344181e-01 7.27538029e-03 1.53516673e-01 3.09418343 0.83908580 401.50 -1.77401618e-01 -5.92757391e-03 1.77500621e-01 -3.10819178 0.85331915 401.75 -2.45143704e-01 2.02215499e-03 2.45152044e-01 3.13334399 0.90780236 402.00 -2.70130359e-01 1.52162095e-02 2.70558578e-01 3.08532298 0.90860918 402.25 -3.09971101e-01 9.55427757e-02 3.24361689e-01 2.84260148 0.90373349 402.50 -3.29920016e-01 1.53146363e-01 3.63732079e-01 2.70699921 0.88938891 402.75 -3.19391535e-01 2.35286772e-01 3.96699908e-01 2.50667623 0.92850573 403.00 -2.86251130e-01 2.75144586e-01 3.97044396e-01 2.37597572 0.92046339 403.25 -2.11757083e-01 2.97195683e-01 3.64919630e-01 2.18987389 0.91886757 403.50 -1.60975375e-01 2.92960676e-01 3.34273883e-01 2.07323850 0.87589067 403.75 -9.64456609e-02 2.80486840e-01 2.96605180e-01 1.90198266 0.88980394 404.00 -6.31420688e-02 2.70944702e-01 2.78204875e-01 1.79975396 0.85252415 404.25 1.58832618e-02 2.35467771e-01 2.36002859e-01 1.50344428 0.81278879 404.50 4.19455940e-02 1.81556366e-01 1.86338796e-01 1.34374663 0.64445556 404.75 7.76741663e-02 8.39670248e-02 1.14384166e-01 0.82430955 0.45247974 405.00 3.74590277e-02 -4.27056389e-03 3.77016773e-02 -0.11351615 0.06085160 405.25 -5.37868659e-02 -1.03694133e-01 1.16813956e-01 -2.04929724 0.44580363 405.50 -1.32381648e-01 -1.11157200e-01 1.72860706e-01 -2.44312501 0.56621430 405.75 -2.38255406e-01 -1.01882925e-01 2.59125006e-01 -2.73750441 0.76744994 406.00 -3.21035716e-01 1.59919922e-03 3.21039699e-01 3.13661132 0.81045657 406.25 -3.41855537e-01 9.28050925e-02 3.54228730e-01 2.87650693 0.89848677 406.50 -2.98440289e-01 1.74592582e-01 3.45758840e-01 2.61226307 0.85036559 406.75 -2.37304625e-01 2.36015119e-01 3.34688843e-01 2.35891887 0.88955398 407.00 -1.34835150e-01 2.34407135e-01 2.70420456e-01 2.09279425 0.80376470 407.25 -8.62139460e-02 2.29158178e-01 2.44839365e-01 1.93063637 0.84230892 407.50 -3.58865606e-02 1.49277091e-01 1.53530111e-01 1.80672169 0.57998193 407.75 -5.06451453e-03 8.21544294e-02 8.23103856e-02 1.63236469 0.35830256 408.00 1.07502197e-03 4.21041400e-02 4.21178618e-02 1.54526942 0.10534948 408.25 -1.77774570e-04 -8.95890918e-04 9.13358820e-04 -1.76668497 0.00005933 408.50 -1.22690103e-02 -6.71664632e-02 6.82778324e-02 -1.75147012 0.25393020 408.75 -2.89932300e-02 -9.78022891e-02 1.02009289e-01 -1.85899064 0.44486545 409.00 -8.72284513e-02 -1.36892190e-01 1.62321515e-01 -2.13812450 0.56021633 409.25 -1.32132310e-01 -1.48051770e-01 1.98439597e-01 -2.29943765 0.66931268 409.50 -1.62302672e-01 -1.48762153e-01 2.20164337e-01 -2.39969660 0.62428228 409.75 -1.59286797e-01 -1.31175240e-01 2.06347346e-01 -2.45267620 0.55439996 410.00 -1.70959348e-01 -1.17153685e-01 2.07248847e-01 -2.54081967 0.54681927 410.25 -1.99301205e-01 -1.31551898e-01 2.38802999e-01 -2.55817386 0.66278178 410.50 -1.85276126e-01 -1.31023418e-01 2.26923730e-01 -2.52606468 0.68456772 410.75 -1.66265578e-01 -1.38976880e-01 2.16699829e-01 -2.44535753 0.64607019 411.00 -1.92834134e-01 -1.98093013e-01 2.76452248e-01 -2.34274298 0.64381318 411.25 -2.12692593e-01 -2.21650414e-01 3.07192196e-01 -2.33557357 0.67815283 411.50 -2.28458978e-01 -3.17684714e-01 3.91301778e-01 -2.19425109 0.76073831 411.75 -2.57061647e-01 -3.27853072e-01 4.16615322e-01 -2.23575166 0.75278176 412.00 -3.46021300e-01 -3.46141594e-01 4.89433083e-01 -2.35602069 0.74516297 412.25 -3.90481687e-01 -3.37915974e-01 5.16394378e-01 -2.42823583 0.69123621 412.50 -4.86422237e-01 -2.79392411e-01 5.60951613e-01 -2.62022258 0.75245324 412.75 -5.44677508e-01 -2.68628357e-01 6.07317695e-01 -2.68340956 0.73486097 413.00 -6.52058600e-01 -2.30385480e-01 6.91561918e-01 -2.80196303 0.65745319 413.25 -6.67211876e-01 -1.47405339e-01 6.83300828e-01 -2.92415800 0.63661312 413.50 -6.99933344e-01 -6.75167860e-02 7.03182197e-01 -3.04542845 0.70130858 413.75 -7.62448008e-01 -6.73950800e-03 7.62477794e-01 -3.13275358 0.70411164 414.00 -8.27742855e-01 1.41168236e-01 8.39694412e-01 2.97267188 0.79800247 414.25 -9.37315521e-01 2.29950284e-01 9.65110107e-01 2.90101543 0.79772702 414.50 -1.07121322e+00 3.26641049e-01 1.11990720e+00 2.84562250 0.75926989 414.75 -1.00233871e+00 6.79026521e-01 1.21068572e+00 2.54616713 0.63835666 415.00 -5.75021708e-01 1.46138558e+00 1.57044508e+00 1.94566687 0.65316435 415.25 -3.85861220e-02 1.52386656e+00 1.52435500e+00 1.59611211 0.59390334 415.50 6.97828370e-01 1.60597952e+00 1.75103816e+00 1.16089084 0.65384825 415.75 1.10045629e+00 1.30160621e+00 1.70445967e+00 0.86894374 0.65671455 416.00 1.48721325e+00 1.11085366e+00 1.85628638e+00 0.64153750 0.74717473 416.25 1.89056244e+00 4.96287199e-01 1.95461692e+00 0.25671553 0.71177046 416.50 2.17577771e+00 -1.58353853e-01 2.18153262e+00 -0.07265225 0.83608109 416.75 1.94484477e+00 -5.19781612e-01 2.01310559e+00 -0.26115740 0.80203378 417.00 1.91880133e+00 -7.14523578e-01 2.04752106e+00 -0.35647186 0.83795107 417.25 2.01766295e+00 -8.81551852e-01 2.20183956e+00 -0.41192125 0.79166365 417.50 2.29938360e+00 -1.23543654e+00 2.61026213e+00 -0.49303296 0.85920149 417.75 2.48654830e+00 -1.66796101e+00 2.99416372e+00 -0.59085436 0.86206948 418.00 2.58389425e+00 -1.88710997e+00 3.19963960e+00 -0.63079666 0.88143279 418.25 2.77080554e+00 -2.36801962e+00 3.64484296e+00 -0.70717715 0.84792838 418.50 2.96293660e+00 -2.82281947e+00 4.09234689e+00 -0.76118529 0.88494136 418.75 3.38029150e+00 -3.26096855e+00 4.69683793e+00 -0.76743318 0.81138358 419.00 3.93346559e+00 -4.07404082e+00 5.66303453e+00 -0.80295179 0.80762378 419.25 4.38435343e+00 -4.21069339e+00 6.07885629e+00 -0.76519625 0.70888561 419.50 4.17041947e+00 -5.86275122e+00 7.19473769e+00 -0.95249897 0.64343121 419.75 3.55915426e+00 -5.62928199e+00 6.66005966e+00 -1.00699534 0.42029253 420.00 3.12293116e+00 -3.51641006e+00 4.70296064e+00 -0.84459367 0.23827161 420.25 9.37097365e-01 1.54265214e-01 9.49710075e-01 0.16315692 0.00966147 420.50 5.74068388e-01 9.22079239e-01 1.08617892e+00 1.01393890 0.01545388 420.75 1.24941860e+00 1.43057573e+00 1.89936667e+00 0.85289158 0.10887873 421.00 9.55812253e-01 1.24208102e+00 1.56727226e+00 0.91491595 0.12000399 421.25 5.37334425e-01 7.20292944e-02 5.42140668e-01 0.13325491 0.03580790 421.50 -5.91520352e-02 -1.00730075e+00 1.00903606e+00 -1.62945228 0.12920694 421.75 -9.77239553e-01 -1.95508759e+00 2.18571833e+00 -2.03431944 0.50927096 422.00 -1.42739410e+00 -2.62906498e+00 2.99156089e+00 -2.06819410 0.65917418 422.25 -2.38681333e+00 -3.55179343e+00 4.27926565e+00 -2.16248374 0.75466845 422.50 -3.10114968e+00 -3.89529461e+00 4.97900085e+00 -2.24317129 0.74899016 422.75 -4.77509865e+00 -5.91345579e+00 7.60069251e+00 -2.25009201 0.73266974 423.00 -5.45645521e+00 -6.95513072e+00 8.84006486e+00 -2.23602814 0.64685197 423.25 -8.22289728e+00 -6.56215011e+00 1.05203543e+01 -2.46805175 0.51770437 423.50 -9.34271551e+00 -2.07427729e+00 9.57021208e+00 -2.92311565 0.42897830 423.75 -8.05765835e+00 6.13057211e+00 1.01247110e+01 2.49119128 0.50267404 424.00 -6.70460650e+00 7.68929415e+00 1.02018132e+01 2.28789085 0.51689819 424.25 -6.07209992e+00 9.33530918e+00 1.11363547e+01 2.14748392 0.66745594 424.50 -3.85240084e+00 8.75072396e+00 9.56117995e+00 1.98550254 0.63389544 424.75 -1.49528424e+00 8.25880498e+00 8.39307659e+00 1.74990936 0.77485190 425.00 -1.33502885e+00 7.76258860e+00 7.87655279e+00 1.74111260 0.81772659 425.25 -8.26933453e-01 7.58561452e+00 7.63055480e+00 1.67938092 0.90222845 425.50 -5.01776166e-01 7.05780561e+00 7.07562007e+00 1.64177211 0.91381764 425.75 -2.41472159e-01 6.83876338e+00 6.84302516e+00 1.60609099 0.93944976 426.00 1.30457016e-01 6.51659418e+00 6.51789987e+00 1.55077980 0.92678121 426.25 6.77747300e-01 6.51924206e+00 6.55437705e+00 1.46720739 0.94429881 426.50 1.06743912e+00 6.14340797e+00 6.23545409e+00 1.39876030 0.93776276 426.75 1.53802726e+00 5.88613727e+00 6.08376033e+00 1.31521422 0.93640858 427.00 2.11010982e+00 5.31012802e+00 5.71401987e+00 1.19255530 0.91903761 427.25 2.45477413e+00 4.77968945e+00 5.37320643e+00 1.09634032 0.94192186 427.50 2.84184054e+00 3.87158718e+00 4.80262897e+00 0.93759806 0.90560790 427.75 3.11145440e+00 3.25404368e+00 4.50221599e+00 0.80779475 0.91419765 428.00 3.07129738e+00 2.45320554e+00 3.93078682e+00 0.67397962 0.87332413 428.25 3.05228718e+00 1.48196750e+00 3.39303473e+00 0.45200223 0.88283778 428.50 2.51322836e+00 5.20498554e-01 2.56656103e+00 0.20421649 0.82479743 428.75 1.91976700e+00 -8.58213625e-03 1.91978618e+00 -0.00447038 0.81937839 429.00 7.10367722e-01 -5.76939200e-02 7.12706734e-01 -0.08103911 0.41678886 429.25 2.28021957e-01 8.28869431e-02 2.42619575e-01 0.34865429 0.15215611 429.50 -1.15912164e-01 5.21626094e-01 5.34349522e-01 1.78945660 0.44356967 429.75 -1.56473747e-01 8.28157323e-01 8.42809934e-01 1.75753699 0.74999725 430.00 -7.07855801e-02 1.00833428e+00 1.01081582e+00 1.64088186 0.86838287 430.25 -2.85828389e-02 1.02202457e+00 1.02242418e+00 1.59875592 0.91135627 430.50 -2.13670145e-02 8.53134238e-01 8.53401768e-01 1.59583641 0.86011646 430.75 -7.74957455e-03 7.74768970e-01 7.74807726e-01 1.58079843 0.86523896 431.00 -1.69336342e-01 7.23589747e-01 7.43139905e-01 1.80068182 0.86189168 431.25 -2.88030901e-01 7.11735100e-01 7.67807693e-01 1.95533784 0.86860988 431.50 -5.40537472e-01 8.38843794e-01 9.97917667e-01 2.14321339 0.88997902 431.75 -6.26867837e-01 9.58622510e-01 1.14539094e+00 2.14992627 0.91835524 432.00 -5.40065669e-01 1.19130740e+00 1.30800774e+00 1.99642319 0.92341750 432.25 -4.06058610e-01 1.30205721e+00 1.36390490e+00 1.87309736 0.92134293 432.50 -1.83294592e-01 1.29652756e+00 1.30941996e+00 1.71123907 0.93054206 432.75 -8.00228181e-02 1.22285998e+00 1.22547550e+00 1.63614223 0.93505142 433.00 5.53354612e-02 1.09976706e+00 1.10115830e+00 1.52052310 0.94834380 433.25 6.82127486e-02 1.03113142e+00 1.03338521e+00 1.50473927 0.94355064 433.50 2.07857327e-02 9.53997723e-01 9.54224136e-01 1.54901174 0.91147750 433.75 2.57525604e-02 8.56433667e-01 8.56820763e-01 1.54073585 0.89106548 434.00 -7.34293774e-03 6.97083506e-01 6.97122180e-01 1.58132974 0.82596059 434.25 -1.65060376e-02 6.70417924e-01 6.70621087e-01 1.59541187 0.73791712 434.50 -1.41470338e-01 6.80165318e-01 6.94722042e-01 1.77586652 0.64014941 434.75 -2.44764009e-01 7.13559184e-01 7.54371347e-01 1.90123807 0.68698947 435.00 -1.69809954e-01 7.59898122e-01 7.78640210e-01 1.79064840 0.68570970 435.25 -1.41722468e-01 9.64726684e-01 9.75080937e-01 1.71665730 0.68572650 435.50 5.35830406e-02 1.27389450e+00 1.27502092e+00 1.52875872 0.82302718 435.75 2.36494549e-01 1.49912957e+00 1.51766898e+00 1.41433121 0.74788741 436.00 4.04213543e-01 2.27558413e+00 2.31120569e+00 1.39499930 0.81485768 436.25 7.79331950e-01 2.87161775e+00 2.97549101e+00 1.30578822 0.77915988 436.50 1.30045943e+00 4.06811176e+00 4.27091653e+00 1.26139139 0.76404433 436.75 1.21536807e+00 5.04933599e+00 5.19354536e+00 1.33459091 0.64936807 437.00 1.00131266e+00 6.52547171e+00 6.60184884e+00 1.41853716 0.58674945 437.25 -1.47572078e+00 7.74710391e+00 7.88640417e+00 1.75902804 0.63354314 437.50 -4.24114746e+00 8.84123908e+00 9.80585745e+00 2.01807292 0.74168282 437.75 -6.12226634e+00 7.59952159e+00 9.75883566e+00 2.24894991 0.76774566 438.00 -7.06193080e+00 6.69239964e+00 9.72928978e+00 2.38305456 0.85168498 438.25 -6.67684979e+00 5.37419664e+00 8.57101585e+00 2.46387102 0.82972412 438.50 -7.42452727e+00 5.42091607e+00 9.19292860e+00 2.51092606 0.89803011 438.75 -7.25307739e+00 4.94365677e+00 8.77763487e+00 2.54332656 0.87494359 439.00 -7.24613471e+00 5.23858697e+00 8.94143510e+00 2.51563004 0.89385346 439.25 -7.62374007e+00 5.18742088e+00 9.22121186e+00 2.54412207 0.89884644 439.50 -7.88770671e+00 5.42345214e+00 9.57234299e+00 2.53924903 0.89369273 439.75 -7.61782046e+00 6.62808016e+00 1.00976549e+01 2.42555848 0.86963760 440.00 -7.24071601e+00 8.32569337e+00 1.10338179e+01 2.28660712 0.89342547 440.25 -6.27297868e+00 9.89565816e+00 1.17164121e+01 2.13577878 0.87848569 440.50 -5.33672262e+00 1.08092713e+01 1.20549141e+01 2.02940504 0.86483836 440.75 -1.42908781e+00 1.20029781e+01 1.20877532e+01 1.68929958 0.73751711 441.00 1.25033343e+00 1.12196030e+01 1.12890578e+01 1.45981240 0.73906658 441.25 2.54921992e+00 7.38995193e+00 7.81728288e+00 1.23862069 0.77642912 441.50 2.28883291e+00 6.28099123e+00 6.68502857e+00 1.22134546 0.83610713 441.75 1.44459823e+00 5.20709658e+00 5.40376895e+00 1.30017354 0.88070118 442.00 1.14402043e+00 4.83406300e+00 4.96758974e+00 1.33841357 0.89746263 442.25 3.66729248e-01 4.23370296e+00 4.24955657e+00 1.48439061 0.90490178 442.50 -2.83382732e-02 3.96894834e+00 3.96904951e+00 1.57793620 0.90128392 442.75 -8.16713526e-01 3.45710401e+00 3.55226535e+00 1.80278506 0.90348064 443.00 -1.22250138e+00 3.43468025e+00 3.64575617e+00 1.91274307 0.89744626 443.25 -1.91304661e+00 3.77685922e+00 4.23372329e+00 2.03964461 0.79452512 443.50 -2.65840404e+00 3.75880097e+00 4.60387845e+00 2.18637010 0.70825197 443.75 -3.56542582e+00 4.00211488e+00 5.35996126e+00 2.29855287 0.68086619 444.00 -4.12267020e+00 4.31323108e+00 5.96660473e+00 2.33360906 0.62946173 444.25 -5.53384617e+00 4.89992725e+00 7.39139638e+00 2.41687634 0.44426898 444.50 -4.09210026e+00 3.32451997e+00 5.27235408e+00 2.45932195 0.14465266 444.75 1.44865695e+00 -3.02425079e+00 3.35331176e+00 -1.12407843 0.09056690 445.00 4.32394762e+00 -1.15737019e+00 4.47616228e+00 -0.26153438 0.31618088 445.25 4.71193931e+00 7.69568979e-01 4.77436996e+00 0.16189382 0.76331889 445.50 4.09262872e+00 1.45387123e+00 4.34319599e+00 0.34133658 0.79325125 445.75 3.20362767e+00 2.18028463e+00 3.87516081e+00 0.59756456 0.82247376 446.00 2.82188527e+00 2.46815887e+00 3.74897915e+00 0.71863112 0.84695449 446.25 2.54919912e+00 3.01497865e+00 3.94822902e+00 0.86891385 0.91700611 446.50 2.45115119e+00 3.37692390e+00 4.17273977e+00 0.94292908 0.92874389 446.75 2.43541177e+00 3.84044885e+00 4.54755735e+00 1.00564592 0.94927294 447.00 2.58938038e+00 4.01971794e+00 4.78152936e+00 0.99853068 0.94140883 447.25 2.94235275e+00 4.29080464e+00 5.20273430e+00 0.96970883 0.94731086 447.50 3.46011528e+00 4.24997951e+00 5.48039447e+00 0.88748748 0.95693904 447.75 3.86456818e+00 4.16688384e+00 5.68311606e+00 0.82302187 0.96353565 448.00 4.43828739e+00 3.84785315e+00 5.87404195e+00 0.71426276 0.95234150 448.25 5.11415644e+00 3.48658956e+00 6.18958019e+00 0.59837414 0.95765863 448.50 5.36274198e+00 2.62534622e+00 5.97088304e+00 0.45525510 0.94314373 448.75 5.44434921e+00 1.52691477e+00 5.65441483e+00 0.27343395 0.91767473 449.00 4.60428012e+00 5.21302882e-01 4.63369746e+00 0.11274125 0.87781623 449.25 4.17837037e+00 -1.81265764e-01 4.18230035e+00 -0.04335474 0.88730092 449.50 3.36566166e+00 -4.88499163e-01 3.40092779e+00 -0.14413558 0.85136182 449.75 3.00238760e+00 -6.08078596e-01 3.06334635e+00 -0.19982868 0.88813953 450.00 2.61879559e+00 -4.58296106e-01 2.65859468e+00 -0.17324822 0.88024470 450.25 2.43469460e+00 -3.60732479e-01 2.46127319e+00 -0.14709322 0.85076982 450.50 2.15715428e+00 -3.47036405e-01 2.18489104e+00 -0.15951021 0.85344772 450.75 2.00408121e+00 -2.59144922e-01 2.02076658e+00 -0.12859503 0.87499390 451.00 2.02379574e+00 -8.34505430e-02 2.02551554e+00 -0.04121132 0.87193183 451.25 1.93954001e+00 7.48600272e-02 1.94098415e+00 0.03857765 0.85851412 451.50 2.07640882e+00 -7.22601898e-02 2.07766579e+00 -0.03478652 0.90141657 451.75 2.16962111e+00 -2.64364596e-01 2.18566795e+00 -0.12125057 0.91506741 452.00 2.05526781e+00 -6.09741593e-01 2.14380749e+00 -0.28840132 0.88511198 452.25 2.09176985e+00 -8.72304018e-01 2.26636612e+00 -0.39508977 0.86968125 452.50 2.06880778e+00 -1.07466048e+00 2.33127878e+00 -0.47909322 0.86502501 452.75 2.12504268e+00 -1.13832254e+00 2.41072284e+00 -0.49177510 0.80324222 453.00 2.28589915e+00 -1.30631504e+00 2.63283002e+00 -0.51917479 0.73687364 453.25 2.42113214e+00 -1.42346753e+00 2.80858339e+00 -0.53150070 0.77970487 453.50 3.01107196e+00 -2.26379180e+00 3.76713521e+00 -0.64466652 0.81678888 453.75 3.37673000e+00 -2.71371492e+00 4.33203810e+00 -0.67696365 0.81565916 454.00 4.70302765e+00 -3.39898548e+00 5.80272103e+00 -0.62581397 0.81476676 454.25 5.33010541e+00 -3.82739210e+00 6.56193218e+00 -0.62275122 0.77983070 454.50 5.90955285e+00 -5.23574373e+00 7.89530412e+00 -0.72501485 0.66026136 454.75 6.07432099e+00 -5.65582407e+00 8.29974225e+00 -0.74973624 0.49212410 455.00 7.35145004e+00 -8.94989846e+00 1.15820767e+01 -0.88314190 0.40978930 455.25 6.27673883e+00 -8.99928472e+00 1.09719905e+01 -0.96176979 0.32508487 455.50 6.67916444e+00 -8.43567348e+00 1.07597316e+01 -0.90109013 0.26131216 455.75 6.55747836e+00 -7.10292600e+00 9.66706161e+00 -0.82530606 0.24883470 456.00 5.28812784e+00 -1.25661720e+01 1.36335239e+01 -1.17246938 0.40376856 456.25 6.39574516e+00 -1.29891733e+01 1.44784039e+01 -1.11325485 0.45335212 456.50 9.89100352e+00 -1.45729476e+01 1.76125737e+01 -0.97449300 0.63404412 456.75 1.08408274e+01 -1.18482115e+01 1.60593790e+01 -0.82976862 0.68794669 457.00 1.26636586e+01 -9.62134998e+00 1.59040443e+01 -0.64971874 0.83006461 457.25 1.29520575e+01 -8.36888384e+00 1.54205710e+01 -0.57365915 0.85899328 457.50 1.22826017e+01 -8.00424094e+00 1.46604972e+01 -0.57755048 0.92565693 457.75 1.17201173e+01 -6.80152541e+00 1.35507157e+01 -0.52583004 0.92214795 458.00 1.10892627e+01 -5.97489645e+00 1.25964731e+01 -0.49420384 0.95318919 458.25 1.03336696e+01 -5.57088001e+00 1.17396521e+01 -0.49443610 0.96451004 458.50 9.88718682e+00 -5.29721994e+00 1.12168178e+01 -0.49184947 0.97452768 458.75 9.03053589e+00 -5.34142175e+00 1.04919667e+01 -0.53413455 0.95849246 459.00 8.48485794e+00 -5.04662246e+00 9.87224456e+00 -0.53657231 0.96591081 459.25 8.03299628e+00 -5.00132914e+00 9.46268050e+00 -0.55687032 0.97187550 459.50 7.80327939e+00 -5.03005438e+00 9.28399786e+00 -0.57257519 0.97810941 459.75 7.30886265e+00 -5.35419803e+00 9.06018266e+00 -0.63224733 0.97088978 460.00 6.91181790e+00 -5.53708626e+00 8.85621539e+00 -0.67541386 0.97309372 460.25 6.13159991e+00 -5.59079450e+00 8.29780095e+00 -0.73929647 0.95951886 460.50 5.57783687e+00 -5.81140968e+00 8.05510687e+00 -0.80590348 0.96419411 460.75 4.59671418e+00 -6.05601137e+00 7.60296356e+00 -0.92153894 0.97109930 461.00 4.08242633e+00 -6.12125469e+00 7.35771457e+00 -0.98261393 0.97391045 461.25 3.28726661e+00 -5.47195956e+00 6.38345229e+00 -1.02982730 0.94653905 461.50 2.84308148e+00 -5.35088362e+00 6.05929599e+00 -1.08240050 0.94124413 461.75 1.95691505e+00 -5.31974464e+00 5.66826248e+00 -1.21830106 0.94724902 462.00 1.52799108e+00 -5.01420998e+00 5.24185640e+00 -1.27500377 0.94939130 462.25 1.00368155e+00 -4.19456422e+00 4.31297411e+00 -1.33593084 0.92071822 462.50 9.23595114e-01 -3.90868119e+00 4.01631879e+00 -1.33875912 0.94245709 462.75 6.19514375e-01 -3.22343168e+00 3.28242438e+00 -1.38092063 0.91315584 463.00 5.38340308e-01 -2.87361209e+00 2.92360338e+00 -1.38560368 0.91909522 463.25 8.17782967e-01 -2.76130244e+00 2.87985419e+00 -1.28286763 0.94280705 463.50 9.36758246e-01 -2.79376192e+00 2.94662887e+00 -1.24727364 0.94767377 463.75 1.14066848e+00 -2.64434193e+00 2.87987306e+00 -1.16354942 0.94891485 464.00 1.04172563e+00 -2.59039063e+00 2.79200930e+00 -1.18843786 0.93640302 464.25 7.80131070e-01 -2.58142725e+00 2.69673342e+00 -1.27731398 0.91670344 464.50 6.15765384e-01 -2.64211774e+00 2.71292336e+00 -1.34182599 0.91342096 464.75 1.98968617e-01 -2.70296908e+00 2.71028234e+00 -1.49731772 0.93485625 465.00 -2.46143741e-02 -2.58251232e+00 2.58262962e+00 -1.58032721 0.93051155 465.25 -1.28754851e-01 -2.12215657e+00 2.12605887e+00 -1.63139375 0.87508851 465.50 -1.98653336e-02 -1.73387286e+00 1.73398665e+00 -1.58225303 0.83404666 465.75 1.19628319e-01 -1.59142793e+00 1.59591785e+00 -1.49576701 0.90708912 466.00 1.23009837e-01 -1.54626946e+00 1.55115462e+00 -1.49141086 0.91274759 466.25 -3.18160963e-02 -1.50810453e+00 1.50844010e+00 -1.59188994 0.94450120 466.50 -3.22863232e-02 -1.35423742e+00 1.35462223e+00 -1.59463277 0.91625478 466.75 1.14252761e-01 -1.21234226e+00 1.21771402e+00 -1.47683251 0.92868797 467.00 1.38001257e-01 -1.24535421e+00 1.25297703e+00 -1.46043373 0.92996190 467.25 -6.61620032e-02 -1.34586996e+00 1.34749522e+00 -1.61991607 0.95632289 467.50 -1.98851802e-01 -1.22993948e+00 1.24591058e+00 -1.73108541 0.96020595 467.75 -2.20570237e-01 -1.11194545e+00 1.13361101e+00 -1.76661857 0.97601531 468.00 -2.31829499e-01 -1.01108481e+00 1.03732223e+00 -1.79618827 0.95341898 468.25 -2.60041885e-01 -8.96236204e-01 9.33199398e-01 -1.85319103 0.94565379 468.50 -2.94972899e-01 -8.14825751e-01 8.66573722e-01 -1.91812780 0.93214834 468.75 -2.92709813e-01 -6.56032613e-01 7.18371647e-01 -1.99047050 0.88652570 469.00 -2.15923388e-01 -4.62578118e-01 5.10491356e-01 -2.00751863 0.78137774 469.25 -1.53999676e-01 -3.62845201e-01 3.94173236e-01 -1.97217774 0.78628309 469.50 -1.37264725e-02 -3.34047038e-01 3.34328939e-01 -1.61186466 0.72868365 469.75 7.91958601e-02 -3.38685717e-01 3.47821792e-01 -1.34109068 0.73778057 470.00 1.03128452e-01 -4.50960442e-01 4.62602202e-01 -1.34597604 0.76377340 470.25 7.89282213e-02 -5.49585593e-01 5.55224268e-01 -1.42815757 0.82737822 470.50 -6.34582740e-03 -5.97972512e-01 5.98006183e-01 -1.58140817 0.83779337 470.75 -7.53411132e-02 -6.20144474e-01 6.24704291e-01 -1.69169346 0.85980367 471.00 -2.33431371e-01 -5.70962883e-01 6.16837757e-01 -1.95889845 0.82304320 471.25 -3.54457679e-01 -5.24152124e-01 6.32752476e-01 -2.16540398 0.82230674 471.50 -5.12800848e-01 -4.24940469e-01 6.65987321e-01 -2.44961538 0.80819901 471.75 -5.54914734e-01 -2.94237045e-01 6.28096968e-01 -2.65404805 0.78441644 472.00 -5.91341728e-01 -3.02588395e-02 5.92115391e-01 -3.09046744 0.76179530 472.25 -5.77288864e-01 1.14440624e-01 5.88522803e-01 2.94589184 0.80211416 472.50 -4.18729250e-01 3.55291461e-01 5.49150441e-01 2.43797049 0.79004158 472.75 -3.74184880e-01 4.59076219e-01 5.92254421e-01 2.25466635 0.86460006 473.00 -1.98865558e-01 5.45305469e-01 5.80435668e-01 1.92049454 0.84327111 473.25 -1.00328922e-01 6.25230756e-01 6.33229335e-01 1.72990693 0.87060676 473.50 4.13737158e-02 7.56308298e-01 7.57439123e-01 1.51614597 0.87581091 473.75 1.81701040e-01 7.80423882e-01 8.01296888e-01 1.34204793 0.88777538 474.00 3.55547082e-01 7.90041416e-01 8.66359721e-01 1.14791246 0.94070888 474.25 4.52214680e-01 7.67471067e-01 8.90791757e-01 1.03833580 0.93662314 474.50 6.26355452e-01 7.01409743e-01 9.40370554e-01 0.84186485 0.95592313 474.75 6.96233873e-01 6.29700476e-01 9.38756782e-01 0.73526171 0.93431892 475.00 8.73360872e-01 4.62982910e-01 9.88489953e-01 0.48744944 0.94854194 475.25 9.07338739e-01 4.15642128e-01 9.98009001e-01 0.42956056 0.94414161 475.50 9.16774585e-01 2.41658888e-01 9.48090005e-01 0.25773419 0.94229772 475.75 9.33588052e-01 1.59179159e-01 9.47061062e-01 0.16887857 0.94932374 476.00 9.87496255e-01 -2.28539366e-02 9.87760677e-01 -0.02313918 0.95672730 476.25 8.91674900e-01 -1.00464566e-01 8.97316697e-01 -0.11219634 0.94885233 476.50 7.37735440e-01 -1.71714789e-01 7.57455971e-01 -0.22868748 0.95210032 476.75 6.97085570e-01 -1.56954941e-01 7.14537015e-01 -0.22146557 0.94049519 477.00 6.42477266e-01 -1.28634840e-01 6.55228174e-01 -0.19760416 0.94579554 477.25 6.26161358e-01 -1.47179874e-01 6.43226214e-01 -0.23086032 0.94295372 477.50 6.10259395e-01 -1.50886859e-01 6.28636121e-01 -0.24238910 0.95638919 477.75 6.04894669e-01 -1.58845700e-01 6.25403484e-01 -0.25680244 0.95242960 478.00 6.17269368e-01 -1.77908604e-01 6.42396251e-01 -0.28061357 0.96856327 478.25 6.18617518e-01 -1.90509995e-01 6.47287951e-01 -0.29874426 0.96302618 478.50 6.21288498e-01 -2.06543335e-01 6.54720968e-01 -0.32094951 0.96485338 478.75 6.36572217e-01 -2.52651617e-01 6.84877381e-01 -0.37782582 0.95098450 479.00 6.45246951e-01 -3.20070634e-01 7.20269976e-01 -0.46047750 0.96721801 479.25 6.11188164e-01 -3.79883620e-01 7.19626665e-01 -0.55611412 0.94671852 479.50 5.33795311e-01 -4.29051202e-01 6.84852078e-01 -0.67703840 0.94443886 479.75 4.34558229e-01 -4.23420455e-01 6.06733662e-01 -0.77241748 0.94370290 480.00 3.99633805e-01 -4.03467462e-01 5.67884822e-01 -0.79017169 0.96425912 480.25 4.07312576e-01 -3.79755489e-01 5.56882183e-01 -0.75040013 0.94727337 480.50 4.23161066e-01 -4.00242850e-01 5.82459979e-01 -0.75757184 0.94402746 480.75 3.91168017e-01 -4.42732214e-01 5.90782727e-01 -0.84715451 0.92201248 481.00 3.47474725e-01 -4.93141695e-01 6.03263968e-01 -0.95698018 0.92266347 481.25 2.76721936e-01 -5.56752100e-01 6.21729789e-01 -1.10952835 0.90881067 481.50 1.93133266e-01 -5.87627937e-01 6.18552384e-01 -1.25325233 0.91233688 481.75 6.56486339e-02 -5.64000055e-01 5.67807894e-01 -1.45491949 0.85288928 482.00 2.99231524e-02 -5.01941719e-01 5.02832859e-01 -1.51125200 0.85878976 482.25 1.91684395e-02 -4.61001059e-01 4.61399399e-01 -1.52924023 0.81825599 482.50 -1.22744438e-02 -5.11929124e-01 5.12076254e-01 -1.59476858 0.82564150 482.75 -1.60367518e-01 -6.60136330e-01 6.79336231e-01 -1.80911074 0.78738286 483.00 -3.84317005e-01 -6.98283611e-01 7.97056812e-01 -2.07392648 0.80813805 483.25 -8.46665296e-01 -5.37168350e-01 1.00269236e+00 -2.57622537 0.78907715 483.50 -1.07100814e+00 -2.45629381e-01 1.09881401e+00 -2.91614732 0.81029178 483.75 -1.07084963e+00 4.36160882e-01 1.15626780e+00 2.75480599 0.70505796 484.00 -8.72530497e-01 8.96772280e-01 1.25120342e+00 2.34249403 0.74850387 484.25 -1.99881800e-01 9.69569930e-01 9.89958880e-01 1.77410320 0.68431611 484.50 1.43950194e-01 8.45113176e-01 8.57285214e-01 1.40208308 0.74470201 484.75 3.05857429e-01 5.88520834e-01 6.63253752e-01 1.09150899 0.81912935 485.00 3.17602275e-01 4.75041185e-01 5.71432702e-01 0.98147138 0.81764256 485.25 1.85038879e-01 3.45359782e-01 3.91807052e-01 1.07893156 0.73604475 485.50 1.82768179e-01 3.50861294e-01 3.95610736e-01 1.09055870 0.75072506 485.75 2.02088695e-01 3.36307209e-01 3.92354915e-01 1.02971163 0.83297593 486.00 1.84764377e-01 3.36698770e-01 3.84062413e-01 1.06891120 0.79873681 486.25 1.79160498e-01 3.03415624e-01 3.52362775e-01 1.03740711 0.78234537 486.50 1.61099315e-01 3.16637127e-01 3.55263367e-01 1.10014771 0.76750888 486.75 8.55961414e-02 3.62989408e-01 3.72945049e-01 1.33921792 0.73974045 487.00 5.49505430e-02 4.04770579e-01 4.08483517e-01 1.43586397 0.74861220 487.25 2.31341729e-02 4.51284354e-01 4.51876928e-01 1.51957820 0.77322580 487.50 2.59245401e-02 5.85286304e-01 5.85860170e-01 1.52653148 0.84126478 487.75 4.25831809e-02 7.06515825e-01 7.07797950e-01 1.51059707 0.90300532 488.00 1.46959980e-01 7.90576526e-01 8.04119692e-01 1.38700451 0.87262637 488.25 3.08247393e-01 8.06042111e-01 8.62971808e-01 1.20553554 0.88173902 488.50 4.56744619e-01 8.18382569e-01 9.37211650e-01 1.06175064 0.89477752 488.75 5.19421466e-01 8.53479795e-01 9.99112816e-01 1.02408270 0.87403492 489.00 6.51132139e-01 8.56494254e-01 1.07589752e+00 0.92078046 0.84110840 489.25 7.24838168e-01 9.37151754e-01 1.18475473e+00 0.91245660 0.89858094 489.50 9.53959083e-01 9.54883878e-01 1.34975596e+00 0.78588264 0.87642340 489.75 1.25302230e+00 1.00965672e+00 1.60918351e+00 0.67825367 0.91056107 490.00 1.50613179e+00 7.71182780e-01 1.69208624e+00 0.47322424 0.92673353 490.25 1.61648764e+00 5.23657855e-01 1.69919093e+00 0.31328006 0.93391722 490.50 1.79944894e+00 2.95498641e-01 1.82355037e+00 0.16276348 0.90761384 490.75 2.02746662e+00 2.58611153e-02 2.02763155e+00 0.01275469 0.90673968 491.00 1.97541137e+00 -6.79175887e-01 2.08890640e+00 -0.33115413 0.87781841 491.25 1.78629983e+00 -1.05156611e+00 2.07283824e+00 -0.53205735 0.87927389 491.50 1.16473254e+00 -1.39711904e+00 1.81894022e+00 -0.87586095 0.81483431 491.75 7.61030620e-01 -1.50870343e+00 1.68977917e+00 -1.10361346 0.85059985 492.00 2.02398349e-01 -1.15884212e+00 1.17638435e+00 -1.39788478 0.75803489 492.25 2.25504945e-02 -1.02631865e+00 1.02656636e+00 -1.54882765 0.84274416 492.50 -9.91060162e-02 -8.58942979e-01 8.64641570e-01 -1.68566973 0.83220936 492.75 -1.51876087e-01 -7.08649483e-01 7.24741633e-01 -1.78192019 0.82349456 493.00 -2.24844753e-01 -5.86092023e-01 6.27741207e-01 -1.93711485 0.85213011 493.25 -2.47922019e-01 -4.89972770e-01 5.49125344e-01 -2.03922558 0.84990556 493.50 -2.40007319e-01 -3.08598459e-01 3.90943119e-01 -2.23181182 0.74470114 493.75 -2.29213894e-01 -2.40895884e-01 3.32520429e-01 -2.33135011 0.75107846 494.00 -1.53856205e-01 -1.51673712e-01 2.16047788e-01 -2.36333767 0.54701093 494.25 -1.40853061e-01 -1.00162388e-01 1.72835438e-01 -2.52344743 0.50361846 494.50 -1.02740583e-01 -8.40536002e-03 1.03083837e-01 -3.05996296 0.32214243 494.75 -6.23901523e-02 4.30153953e-03 6.25382630e-02 3.07275578 0.17884654 495.00 -9.46425379e-04 2.24720682e-02 2.24919890e-02 1.61288709 0.03742568 495.25 2.79521086e-02 4.87999071e-02 5.62383437e-02 1.05062436 0.19091347 495.50 6.89939858e-02 9.59904121e-02 1.18213067e-01 0.94759097 0.56209959 495.75 9.39688926e-02 9.75607661e-02 1.35455734e-01 0.80414958 0.62705428 496.00 1.09468869e-01 9.11627880e-02 1.42457317e-01 0.69440787 0.69127878 496.25 1.23950008e-01 8.92745467e-02 1.52753229e-01 0.62418531 0.66441714 496.50 1.86658649e-01 8.39690997e-02 2.04675991e-01 0.42273233 0.79227354 496.75 2.07703916e-01 7.95748432e-02 2.22425431e-01 0.36586764 0.86670267 497.00 2.20591719e-01 4.96153491e-02 2.26102608e-01 0.22123769 0.86771611 497.25 2.25664194e-01 3.90109136e-02 2.29011310e-01 0.17117970 0.87180278 497.50 2.12368444e-01 -5.47197438e-04 2.12369149e-01 -0.00257664 0.83340621 497.75 1.99068062e-01 -1.36411241e-02 1.99534893e-01 -0.06841797 0.79749790 498.00 1.76699656e-01 -2.45585157e-02 1.78398120e-01 -0.13809984 0.79488915 498.25 1.60204720e-01 -2.41202677e-02 1.62010308e-01 -0.14943663 0.72794596 498.50 1.43071693e-01 -8.03989616e-03 1.43297415e-01 -0.05613584 0.62744982 498.75 1.21668432e-01 3.28977900e-02 1.26037581e-01 0.26407425 0.51208122 499.00 1.03518811e-01 4.91564149e-02 1.14597109e-01 0.44332994 0.49015277 499.25 1.07747694e-01 7.52065030e-02 1.31398568e-01 0.60937376 0.54432814 499.50 1.12060097e-01 1.18620932e-01 1.63182079e-01 0.81383165 0.66683924 499.75 1.27892921e-01 1.52078021e-01 1.98706627e-01 0.87156857 0.60983425 500.00 1.50596104e-01 1.93350350e-01 2.45078649e-01 0.90906874 0.65659972 500.25 1.62069145e-01 1.96462237e-01 2.54683762e-01 0.88103324 0.64816949 500.50 1.56924102e-01 2.45896991e-01 2.91702766e-01 1.00278240 0.68821198 500.75 2.08789509e-01 2.80640252e-01 3.49788522e-01 0.93116198 0.70567192 501.00 2.72552438e-01 2.81237114e-01 3.91636497e-01 0.80107915 0.71847857 501.25 3.87908600e-01 3.24440109e-01 5.05701954e-01 0.69653531 0.76005436 501.50 4.64756072e-01 3.62654040e-01 5.89505012e-01 0.66261931 0.82188258 501.75 6.15479635e-01 4.27549411e-01 7.49408887e-01 0.60713343 0.87178186 502.00 7.06232520e-01 4.48790914e-01 8.36766190e-01 0.56609425 0.88351072 502.25 7.88011080e-01 3.92428033e-01 8.80318819e-01 0.46204482 0.86179031 502.50 8.84296754e-01 3.11753982e-01 9.37641346e-01 0.33893986 0.82551051 502.75 1.20272474e+00 4.58977655e-02 1.20360019e+00 0.03814298 0.79039718 503.00 1.40974259e+00 -1.41179589e-01 1.41679421e+00 -0.09981286 0.85212458 503.25 1.51991020e+00 -5.04593059e-01 1.60148093e+00 -0.32053993 0.90744226 503.50 1.43570477e+00 -7.78693114e-01 1.63328232e+00 -0.49697172 0.89485418 503.75 1.15615474e+00 -1.12935613e+00 1.61621133e+00 -0.77367326 0.87679880 504.00 9.44034981e-01 -1.10169157e+00 1.45083644e+00 -0.86231244 0.88667898 504.25 9.62226175e-01 -1.10647438e+00 1.46634401e+00 -0.85501438 0.89108994 504.50 1.04143813e+00 -1.13292012e+00 1.53886367e+00 -0.82744646 0.89691135 504.75 1.21554170e+00 -1.53702047e+00 1.95958504e+00 -0.90166398 0.82111051 505.00 1.24258219e+00 -1.86274611e+00 2.23915912e+00 -0.98251449 0.83780150 505.25 1.33835599e+00 -2.39792811e+00 2.74613473e+00 -1.06173259 0.83590397 505.50 1.50479091e+00 -2.76090370e+00 3.14435763e+00 -1.07177251 0.82313258 505.75 1.60039150e+00 -3.28572171e+00 3.65475308e+00 -1.11754242 0.70220896 506.00 1.55409418e+00 -3.33426720e+00 3.67866097e+00 -1.13463651 0.63262763 506.25 6.28872825e-01 -3.09750437e+00 3.16069839e+00 -1.37049319 0.41296901 506.50 -1.25815994e-01 -2.32879197e+00 2.33218818e+00 -1.62477015 0.31426972 506.75 -4.50972889e-01 -1.18402934e+00 1.26700514e+00 -1.93471192 0.19875744 507.00 -3.02792209e-01 -7.89726554e-01 8.45784341e-01 -1.93692316 0.13574346 507.25 3.70539334e-01 -5.41323159e-01 6.55995549e-01 -0.97054440 0.30404147 507.50 6.22543943e-01 -5.23390462e-01 8.13325603e-01 -0.69908682 0.47486437 507.75 8.51606644e-01 -6.69025568e-01 1.08297234e+00 -0.66590103 0.65760174 508.00 9.55838523e-01 -9.07405933e-01 1.31795782e+00 -0.75941033 0.83317445 508.25 8.66640174e-01 -1.07504465e+00 1.38086429e+00 -0.89232061 0.91210003 508.50 7.62469172e-01 -1.06440437e+00 1.30931887e+00 -0.94919178 0.90653904 508.75 7.18652182e-01 -1.04364175e+00 1.26714208e+00 -0.96776211 0.89293442 509.00 7.55830369e-01 -1.05764256e+00 1.29995667e+00 -0.95031436 0.91094057 509.25 7.93106525e-01 -9.86438164e-01 1.26573228e+00 -0.89361481 0.88969591 509.50 9.13270126e-01 -9.32543355e-01 1.30525838e+00 -0.79583937 0.87721361 509.75 9.79162103e-01 -1.01524645e+00 1.41049062e+00 -0.80348895 0.90883142 510.00 1.12456106e+00 -1.07770967e+00 1.55759293e+00 -0.76412724 0.88083485 510.25 1.35540206e+00 -1.18578282e+00 1.80088745e+00 -0.71874894 0.85087488 510.50 1.29180506e+00 -1.44638172e+00 1.93927316e+00 -0.84179051 0.80828077 510.75 1.42185756e+00 -1.91480509e+00 2.38498584e+00 -0.93207388 0.81273220 511.00 1.62929928e+00 -2.08048213e+00 2.64254083e+00 -0.90642358 0.75579989 511.25 9.94641481e-01 -2.77126386e+00 2.94435308e+00 -1.22620373 0.72242302 511.50 4.44289324e-01 -2.90439356e+00 2.93817885e+00 -1.41900158 0.74247948 511.75 1.83025279e-01 -2.72544351e+00 2.73158206e+00 -1.50374269 0.70390934 512.00 -2.70892345e-01 -2.62611129e+00 2.64004605e+00 -1.67358619 0.65448362 512.25 -8.13028595e-01 -2.61708359e+00 2.74046383e+00 -1.87200590 0.66852796 512.50 -5.21361547e-01 -2.33608841e+00 2.39355947e+00 -1.79037508 0.67615288 512.75 -4.92412825e-01 -2.33930826e+00 2.39057180e+00 -1.77826262 0.70937776 513.00 -9.36607832e-01 -2.73586200e+00 2.89174258e+00 -1.90063506 0.63988544 513.25 -1.39316099e+00 -2.70216122e+00 3.04016000e+00 -2.04682447 0.62688177 513.50 -4.66115694e-01 -2.35762578e+00 2.40326094e+00 -1.76598471 0.50240070 513.75 -2.42018281e-01 -2.35568475e+00 2.36808435e+00 -1.67317510 0.53344361 514.00 -4.34874022e-01 -2.54105078e+00 2.57799427e+00 -1.74029372 0.52935175 514.25 -2.84219909e-01 -2.45394639e+00 2.47035095e+00 -1.68610412 0.57357099 514.50 1.99719365e-01 -1.91082188e+00 1.92123088e+00 -1.46665432 0.46246925 514.75 3.15409169e-01 -1.81179028e+00 1.83903968e+00 -1.39843665 0.47772829 515.00 5.61464765e-01 -1.24338977e+00 1.36428032e+00 -1.14664607 0.47163016 515.25 6.11788841e-01 -1.15762707e+00 1.30934565e+00 -1.08462105 0.58743946 515.50 5.55340381e-01 -1.04337181e+00 1.18195925e+00 -1.08167852 0.70363755 515.75 5.37503463e-01 -9.82562084e-01 1.11997242e+00 -1.07022639 0.69855755 516.00 4.45494686e-01 -9.01761776e-01 1.00580307e+00 -1.11193851 0.73659260 516.25 3.46132914e-01 -9.45680187e-01 1.00703476e+00 -1.21992630 0.73731375 516.50 1.93872599e-01 -9.98467189e-01 1.01711519e+00 -1.37901255 0.67411982 516.75 1.06315016e-01 -1.08554327e+00 1.09073694e+00 -1.47317051 0.75126409 517.00 -2.55721431e-01 -1.17035338e+00 1.19796514e+00 -1.78591479 0.83554770 517.25 -4.39467613e-01 -1.21189626e+00 1.28911766e+00 -1.91867651 0.87349356 517.50 -7.63422144e-01 -1.12721365e+00 1.36140515e+00 -2.16610026 0.88927975 517.75 -9.47135333e-01 -9.70101403e-01 1.35578836e+00 -2.34421633 0.84175731 518.00 -1.26622893e+00 -6.37252588e-01 1.41754244e+00 -2.67533401 0.80405930 518.25 -1.37689725e+00 -2.10497676e-01 1.39289458e+00 -2.98988896 0.79458409 518.50 -1.29613699e+00 2.57432247e-01 1.32145468e+00 2.94552918 0.85733399 518.75 -1.10965626e+00 3.73208596e-01 1.17073553e+00 2.81714922 0.85553128 519.00 -8.08906640e-01 3.65106825e-01 8.87486871e-01 2.71760964 0.90778745 519.25 -7.11608556e-01 3.11769429e-01 7.76908562e-01 2.72866254 0.90456506 519.50 -6.73362053e-01 2.33379756e-01 7.12658799e-01 2.80795998 0.90584306 519.75 -7.00289665e-01 1.95779623e-01 7.27141854e-01 2.86898321 0.91920715 520.00 -7.41388760e-01 1.56096081e-01 7.57643241e-01 2.93407804 0.93893531 520.25 -7.83209368e-01 1.35534425e-01 7.94849982e-01 2.97023961 0.92441951 520.50 -8.51936641e-01 9.22109084e-02 8.56912418e-01 3.03377556 0.91791605 520.75 -1.02884500e+00 1.27084096e-01 1.03666408e+00 3.01869404 0.90494256 521.00 -1.21992706e+00 2.29533483e-01 1.24133301e+00 2.95561352 0.93317881 521.25 -1.39264041e+00 5.20021193e-01 1.48656293e+00 2.78421962 0.87400592 521.50 -1.51560669e+00 9.34878371e-01 1.78074738e+00 2.58888678 0.88214751 521.75 -1.17436500e+00 1.46588779e+00 1.87828649e+00 2.24622521 0.88790106 522.00 -9.16504174e-01 1.70736622e+00 1.93780270e+00 2.06344418 0.90225914 522.25 -2.46318715e-01 1.83579811e+00 1.85224934e+00 1.70417500 0.87354602 522.50 9.76621672e-02 1.67594309e+00 1.67878621e+00 1.51258919 0.90115982 522.75 3.68596262e-01 1.44862893e+00 1.49478727e+00 1.32163861 0.87425067 523.00 4.95825127e-01 1.19545110e+00 1.29419701e+00 1.17763104 0.86092705 523.25 6.85526520e-01 8.96046518e-01 1.12820476e+00 0.91772828 0.79079475 523.50 8.55513121e-01 6.44838795e-01 1.07131684e+00 0.64589365 0.78714626 523.75 9.70039179e-01 2.53660955e-01 1.00265642e+00 0.25576843 0.77027636 524.00 8.88138299e-01 6.70053057e-03 8.88163574e-01 0.00754432 0.75989667 524.25 6.04180669e-01 -2.86482393e-01 6.68660184e-01 -0.44276827 0.57816585 524.50 3.51801297e-01 -4.13022312e-01 5.42541780e-01 -0.86527378 0.44399056 524.75 -1.16633016e-01 -5.72027079e-01 5.83796402e-01 -1.77193351 0.53953981 525.00 -2.66035777e-01 -5.62512005e-01 6.22249781e-01 -2.01256451 0.65959376 525.25 -5.22628586e-01 -3.70216901e-01 6.40469510e-01 -2.52526813 0.67301183 525.50 -6.46338088e-01 -2.92388531e-01 7.09396910e-01 -2.71676371 0.72186004 525.75 -8.23996177e-01 -5.31354426e-02 8.25707621e-01 -3.07719675 0.80562155 526.00 -8.58994988e-01 1.08780608e-01 8.65855421e-01 3.01562610 0.83590673 526.25 -8.32249281e-01 3.56076424e-01 9.05223334e-01 2.73731196 0.83980044 526.50 -7.55555766e-01 4.94298357e-01 9.02881709e-01 2.56225778 0.84480647 526.75 -5.90758376e-01 6.71323553e-01 8.94243128e-01 2.29244585 0.88968224 527.00 -4.98146454e-01 7.30299384e-01 8.84017579e-01 2.16941622 0.89425424 527.25 -3.20756953e-01 7.70316473e-01 8.34429441e-01 1.96535708 0.88992289 527.50 -2.11988515e-01 7.77870931e-01 8.06239614e-01 1.83685919 0.89546334 527.75 -8.63402706e-02 7.26030198e-01 7.31146011e-01 1.68916148 0.89025335 528.00 -6.78497412e-02 6.52137616e-01 6.55657729e-01 1.67446540 0.87274190 528.25 4.70886266e-03 5.59353753e-01 5.59373573e-01 1.56237813 0.82576172 528.50 4.54961628e-02 4.71813837e-01 4.74002318e-01 1.47466534 0.81106404 528.75 2.18040745e-02 3.89170034e-01 3.89780365e-01 1.51482772 0.85504989 529.00 2.57386052e-03 3.53797857e-01 3.53807219e-01 1.56352151 0.79182668 529.25 -5.00099617e-02 3.02130700e-01 3.06241663e-01 1.73483327 0.79326317 529.50 -6.53531745e-02 3.62021073e-01 3.67872661e-01 1.74939592 0.88090141 529.75 -5.84242678e-02 3.96757046e-01 4.01035595e-01 1.71700013 0.93817173 530.00 -1.94168391e-02 3.76769378e-01 3.77269371e-01 1.62228585 0.89850334 530.25 -3.92627434e-03 3.30776447e-01 3.30799748e-01 1.58266564 0.92452807 530.50 -1.62615043e-02 3.22962412e-01 3.23371545e-01 1.62110491 0.90061812 530.75 -3.60490998e-02 3.05885394e-01 3.08002292e-01 1.68810687 0.89536368 531.00 -5.37496148e-02 3.07282251e-01 3.11947757e-01 1.74396375 0.89849932 531.25 -4.11228659e-02 3.04315319e-01 3.07081265e-01 1.70511510 0.93016141 531.50 -1.74789339e-02 3.18280130e-01 3.18759712e-01 1.62565804 0.90824430 531.75 4.86626893e-03 3.20998983e-01 3.21035867e-01 1.55563772 0.89980294 532.00 9.00841726e-03 2.95439894e-01 2.95577203e-01 1.54031423 0.83070853 532.25 1.17822645e-03 2.69688359e-01 2.69690933e-01 1.56642751 0.77789036 532.50 -6.85628893e-03 2.25923799e-01 2.26027812e-01 1.60113481 0.68321689 532.75 -3.71388699e-02 1.78166784e-01 1.81996424e-01 1.77630355 0.58341754 533.00 -9.35628320e-02 1.58334026e-01 1.83912118e-01 2.10451302 0.62164463 533.25 -1.18573994e-01 1.42717515e-01 1.85548056e-01 2.26405541 0.60647903 533.50 -1.93162697e-01 1.41607250e-01 2.39508748e-01 2.50899666 0.59225411 533.75 -2.62608992e-01 1.86295636e-01 3.21977556e-01 2.52458371 0.69213779 534.00 -3.17106118e-01 3.43514340e-01 4.67502291e-01 2.31624089 0.75084556 534.25 -3.30471272e-01 4.52368008e-01 5.60221452e-01 2.20172388 0.82442780 534.50 -1.89460948e-01 5.90943498e-01 6.20572050e-01 1.88105029 0.87211355 534.75 -1.14906274e-01 6.47464605e-01 6.57581832e-01 1.74643868 0.87305696 535.00 1.29119784e-01 6.21182579e-01 6.34460176e-01 1.36585343 0.80088466 535.25 2.56205936e-01 5.77022923e-01 6.31345337e-01 1.15293196 0.83802082 535.50 4.06366602e-01 4.57180773e-01 6.11676446e-01 0.84417391 0.77268665 535.75 4.60208829e-01 3.53765571e-01 5.80467265e-01 0.65536624 0.76888411 536.00 4.32337461e-01 1.19087229e-01 4.48438902e-01 0.26878426 0.68091214 536.25 3.71274023e-01 4.07123515e-03 3.71296344e-01 0.01096514 0.61972374 536.50 2.21624538e-01 -1.93308869e-01 2.94084605e-01 -0.71726232 0.49670771 536.75 1.24142172e-01 -2.20985483e-01 2.53467675e-01 -1.05896448 0.45834961 537.00 -4.77831793e-02 -2.24610785e-01 2.29637185e-01 -1.78040913 0.45490186 537.25 -1.13245854e-01 -2.22799972e-01 2.49928892e-01 -2.04104984 0.47351521 537.50 -2.51811616e-01 -1.63711885e-01 3.00350913e-01 -2.56512159 0.51256839 537.75 -3.18435941e-01 -1.11111925e-01 3.37264449e-01 -2.80587118 0.52543023 538.00 -4.09445286e-01 1.68575821e-03 4.09448756e-01 3.13747550 0.41832739 538.25 -3.40280467e-01 8.32832339e-02 3.50323983e-01 2.90156238 0.24447162 538.50 -3.25647683e-01 2.97152667e-01 4.40847049e-01 2.40191566 0.31399181 538.75 -3.13342074e-01 2.64168234e-01 4.09839129e-01 2.44113759 0.35758359 539.00 -3.67108549e-01 4.19115053e-02 3.69493249e-01 3.02791831 0.37947139 539.25 -5.89474993e-01 6.67272599e-02 5.93239661e-01 3.02887469 0.48506623 539.50 -9.62425312e-01 5.45811534e-01 1.10642339e+00 2.62569987 0.60553083 539.75 -8.03176739e-01 9.04238723e-01 1.20943811e+00 2.29707343 0.60557400 540.00 -4.28896671e-01 1.27253310e+00 1.34286740e+00 1.89588066 0.74523464 540.25 -1.20477588e-01 1.33825887e+00 1.34367096e+00 1.66057992 0.71702097 540.50 2.57073327e-01 1.33459205e+00 1.35912568e+00 1.38050385 0.76290372 540.75 5.05195902e-01 1.15108452e+00 1.25706741e+00 1.15722240 0.72458422 541.00 7.23065291e-01 9.57712883e-01 1.20001558e+00 0.92410817 0.77437160 541.25 8.01726345e-01 7.44058345e-01 1.09379521e+00 0.74810884 0.78055524 541.50 8.29816409e-01 5.62592248e-01 1.00254941e+00 0.59578855 0.83080287 541.75 7.80324642e-01 4.39143375e-01 8.95406864e-01 0.51259461 0.73903718 542.00 7.92700759e-01 3.39512208e-01 8.62347397e-01 0.40466083 0.74242355 542.25 7.80267067e-01 2.19656827e-01 8.10595965e-01 0.27441294 0.63961131 542.50 7.13534732e-01 1.04822962e-01 7.21193225e-01 0.14586325 0.54089947 542.75 4.11949590e-01 2.44425682e-02 4.12674089e-01 0.05926440 0.12695205 543.00 4.07843814e-01 -1.35572782e-01 4.29786640e-01 -0.32092246 0.08856299 543.25 7.29084605e-01 -2.36688526e-01 7.66541466e-01 -0.31390440 0.42122147 543.50 7.88714710e-01 -1.02735249e-01 7.95377537e-01 -0.12952727 0.61435453 543.75 8.41194779e-01 -6.83912346e-02 8.43970388e-01 -0.08112406 0.73390996 544.00 8.42498675e-01 -1.72971510e-01 8.60071602e-01 -0.20249392 0.76223390 544.25 7.34588981e-01 -4.98090671e-01 8.87533260e-01 -0.59584446 0.80852697 544.50 6.49167897e-01 -5.80300534e-01 8.70728240e-01 -0.72944270 0.84717864 544.75 3.51176505e-01 -6.02289899e-01 6.97192987e-01 -1.04291920 0.73629441 545.00 2.59823101e-01 -6.03299843e-01 6.56870416e-01 -1.16413302 0.78773915 545.25 2.04007261e-01 -5.70778799e-01 6.06141403e-01 -1.22752739 0.78968259 545.50 1.21787892e-01 -5.53797090e-01 5.67030429e-01 -1.35432778 0.78850001 545.75 -4.75971717e-02 -5.11944286e-01 5.14152159e-01 -1.66350316 0.76620514 546.00 -1.03769072e-01 -4.44400758e-01 4.56355184e-01 -1.80018951 0.71866130 546.25 -1.11528656e-01 -3.37390556e-01 3.55346349e-01 -1.89005104 0.41606729 546.50 -9.88572485e-02 -2.07787082e-01 2.30104817e-01 -2.01486640 0.15017138 546.75 1.66554013e-01 -1.90664676e-02 1.67641789e-01 -0.11398002 0.10454358 547.00 3.10792292e-01 1.31081388e-02 3.11068597e-01 0.04215154 0.25108283 547.25 4.91610494e-01 -1.70847650e-01 5.20451532e-01 -0.33446951 0.45965477 547.50 6.22105773e-01 -3.24765812e-01 7.01775195e-01 -0.48112591 0.52876567 547.75 7.01135995e-01 -6.53137918e-01 9.58217524e-01 -0.74997107 0.57907177 548.00 6.88673415e-01 -9.57794346e-01 1.17967838e+00 -0.94741890 0.66113541 548.25 4.45608926e-01 -1.64060247e+00 1.70004228e+00 -1.30558172 0.70006742 548.50 -2.89358281e-02 -1.78261021e+00 1.78284504e+00 -1.58702718 0.57445582 548.75 -1.09024662e+00 -1.56448629e+00 1.90689671e+00 -2.17941985 0.43779700 549.00 -1.42614106e+00 -7.97606671e-01 1.63403021e+00 -2.63165555 0.33507316 549.25 -1.82789246e+00 1.46082254e-01 1.83372050e+00 3.06184374 0.56159284 549.50 -1.77026840e+00 4.24045471e-01 1.82034744e+00 2.90648513 0.61956101 549.75 -1.50340091e+00 6.98764123e-01 1.65785572e+00 2.70650853 0.71801711 550.00 -1.24659601e+00 8.18312444e-01 1.49118639e+00 2.56070521 0.66902519 550.25 -9.53249779e-01 8.88589777e-01 1.30317955e+00 2.39128629 0.68893274 550.50 -5.82799413e-01 8.47959345e-01 1.02892673e+00 2.17294541 0.54990060 550.75 -4.09436168e-01 9.33841819e-01 1.01965608e+00 1.98399778 0.67218971 551.00 -3.23037480e-01 1.07445303e+00 1.12196369e+00 1.86285206 0.70515467 551.25 -2.31560470e-01 1.15017611e+00 1.17325416e+00 1.76946666 0.72603493 551.50 -9.65345956e-02 1.10962952e+00 1.11382072e+00 1.65757498 0.67982266 551.75 6.35869068e-02 1.11577247e+00 1.11758288e+00 1.51386877 0.81147068 552.00 2.77289131e-01 1.18734917e+00 1.21929788e+00 1.34137192 0.80970030 552.25 5.97664515e-01 1.20169466e+00 1.34211510e+00 1.10926985 0.87285373 552.50 9.29403084e-01 1.10555784e+00 1.44431583e+00 0.87174711 0.85511556 552.75 1.27845907e+00 9.21981942e-01 1.57623231e+00 0.62479092 0.86248867 553.00 1.56325534e+00 6.92591506e-01 1.70981001e+00 0.41705460 0.84413954 553.25 1.79758417e+00 3.21379866e-01 1.82608703e+00 0.17691516 0.81134332 553.50 1.89072024e+00 -4.26101539e-01 1.93813971e+00 -0.22166151 0.83179990 553.75 1.71172652e+00 -8.06387138e-01 1.89215959e+00 -0.44025803 0.83522630 554.00 1.22096873e+00 -1.01885106e+00 1.59022707e+00 -0.69540355 0.77062919 554.25 1.06228530e+00 -1.30002248e+00 1.67884141e+00 -0.88569815 0.74456081 554.50 1.09116800e+00 -1.26713072e+00 1.67220449e+00 -0.85987442 0.78134608 554.75 8.97065972e-01 -1.09818846e+00 1.41800749e+00 -0.88585925 0.68723718 555.00 5.16253291e-01 -1.37074270e+00 1.46473650e+00 -1.21060347 0.69065689 555.25 4.61033852e-01 -1.36831558e+00 1.44389741e+00 -1.24580749 0.71213077 555.50 4.30601277e-01 -1.29644988e+00 1.36608922e+00 -1.25012126 0.64445034 555.75 3.29484027e-01 -1.29005682e+00 1.33146773e+00 -1.32073925 0.62957526 556.00 4.10066026e-01 -1.31097441e+00 1.37361131e+00 -1.26764287 0.65424291 556.25 6.01644285e-01 -1.34666559e+00 1.47495223e+00 -1.15063512 0.61477161 556.50 8.87976484e-01 -1.84017085e+00 2.04321585e+00 -1.12120502 0.71952984 556.75 8.91578209e-01 -2.17864245e+00 2.35401670e+00 -1.18235360 0.75480226 557.00 3.78838856e-01 -3.02757946e+00 3.05118932e+00 -1.44631404 0.73155478 557.25 -5.49914544e-01 -3.13005984e+00 3.17799947e+00 -1.74470965 0.73169705 557.50 -1.58372785e+00 -3.40615668e+00 3.75634094e+00 -2.00602141 0.79109274 557.75 -1.96392825e+00 -3.32129060e+00 3.85849523e+00 -2.10480517 0.76546277 558.00 -2.76881797e+00 -2.35003089e+00 3.63166602e+00 -2.43782543 0.71195133 558.25 -3.17208841e+00 -1.65176588e+00 3.57637741e+00 -2.66150777 0.78235320 558.50 -2.90135798e+00 -1.40397769e+00 3.22320206e+00 -2.69090485 0.78559446 558.75 -2.60351080e+00 -8.98178325e-01 2.75408656e+00 -2.80939040 0.75101293 559.00 -2.34642502e+00 -5.57832407e-01 2.41182242e+00 -2.90818837 0.72153901 559.25 -2.31657609e+00 -5.72500401e-01 2.38626937e+00 -2.89931497 0.72132178 559.50 -2.37938824e+00 -2.03288668e-01 2.38805668e+00 -3.05636227 0.77189158 559.75 -2.42640057e+00 -1.95522971e-01 2.43426559e+00 -3.06118490 0.78843911 560.00 -2.07182892e+00 -7.27363478e-02 2.07310532e+00 -3.10649975 0.65044497 560.25 -1.74172240e+00 -6.38043231e-02 1.74289068e+00 -3.10497614 0.62077750 560.50 -1.59706176e+00 -5.78299072e-01 1.69853939e+00 -2.79417759 0.59921446 560.75 -1.72831166e+00 -6.86489724e-01 1.85965840e+00 -2.76350023 0.55530221 561.00 -2.12212552e+00 -9.04059017e-01 2.30667280e+00 -2.73886192 0.72905181 561.25 -2.26379024e+00 -1.01814539e+00 2.48220996e+00 -2.71894454 0.73878750 561.50 -2.53561523e+00 -1.10310405e+00 2.76517326e+00 -2.73124555 0.69927209 561.75 -2.94365284e+00 -1.45170031e+00 3.28215262e+00 -2.68342969 0.70017385 562.00 -3.65631481e+00 -1.72021019e+00 4.04076244e+00 -2.70184155 0.71753509 562.25 -4.06310239e+00 -8.65827539e-01 4.15433008e+00 -2.93163786 0.64313180 562.50 -4.48180967e+00 4.80895466e-01 4.50753573e+00 3.03470222 0.54126598 562.75 -2.72977506e+00 4.98553543e-01 2.77492838e+00 2.96094821 0.23945147 563.00 -1.09704132e+00 1.80481811e+00 2.11207672e+00 2.11696088 0.13317490 563.25 -3.84313927e-01 1.96572057e+00 2.00293649e+00 1.76386886 0.23159145 563.50 -4.47728057e-02 1.94043769e+00 1.94095415e+00 1.59386579 0.32578539 563.75 5.82284677e-01 1.75069526e+00 1.84499034e+00 1.24970415 0.47072940 564.00 8.32367480e-01 1.37966091e+00 1.61130377e+00 1.02794429 0.51932467 564.25 3.88503053e-01 1.18669559e+00 1.24867171e+00 1.25441129 0.38217235 564.50 2.67060772e-01 1.20711006e+00 1.23629937e+00 1.35306378 0.39937371 564.75 4.17173840e-01 8.15349098e-01 9.15875627e-01 1.09787175 0.29678891 565.00 3.79857960e-01 7.09609711e-01 8.04883850e-01 1.07930486 0.26793244 565.25 -8.91454920e-05 5.39601375e-01 5.39601383e-01 1.57096153 0.11812406 565.50 -8.55680773e-02 5.57972012e-01 5.64495050e-01 1.72296631 0.12344455 565.75 1.55165729e-01 1.62691358e-01 2.24821888e-01 0.80906988 0.03780993 566.00 2.95237622e-01 6.40631219e-02 3.02108155e-01 0.21367587 0.07298230 566.25 5.50989832e-01 -3.52028634e-01 6.53845512e-01 -0.56853402 0.24455981 566.50 3.96150960e-01 -8.66213899e-01 9.52503072e-01 -1.14185840 0.48893195 566.75 -5.56360257e-02 -1.31126324e+00 1.31244301e+00 -1.61320023 0.61927357 567.00 -4.04322308e-01 -1.62220972e+00 1.67183758e+00 -1.81506117 0.75049258 567.25 -9.99128410e-01 -1.83690118e+00 2.09104364e+00 -2.06896008 0.85605546 567.50 -1.51921017e+00 -1.96141662e+00 2.48095842e+00 -2.22982358 0.87879970 567.75 -2.28622336e+00 -1.64038448e+00 2.81383698e+00 -2.51921247 0.92789323 568.00 -2.46781226e+00 -1.37426262e+00 2.82465840e+00 -2.63348656 0.94553385 568.25 -2.87788559e+00 -9.84089501e-01 3.04148937e+00 -2.81210833 0.96245750 568.50 -3.07329270e+00 -8.49216863e-01 3.18846315e+00 -2.87199827 0.96540889 568.75 -3.31834554e+00 -5.13468536e-01 3.35783667e+00 -2.98807387 0.97630122 569.00 -3.42110999e+00 -4.02418339e-01 3.44469652e+00 -3.02450270 0.97829792 569.25 -3.61726111e+00 -2.26385087e-01 3.62433830e+00 -3.07908951 0.97333943 569.50 -3.71377532e+00 -8.81848688e-02 3.71482216e+00 -3.11785177 0.96867940 569.75 -3.85837380e+00 -1.65899958e-03 3.85837415e+00 -3.14116268 0.96233819 570.00 -3.97889347e+00 1.07212597e-01 3.98033765e+00 3.11465384 0.96385737 570.25 -4.36212847e+00 3.18243970e-01 4.37372199e+00 3.06876556 0.96724595 570.50 -4.52391680e+00 4.01702590e-01 4.54171644e+00 3.05302962 0.96365667 570.75 -4.59575919e+00 8.45289269e-01 4.67284887e+00 2.95969751 0.94285688 571.00 -4.66600230e+00 1.20668125e+00 4.81950798e+00 2.88852574 0.94485497 571.25 -4.63728945e+00 1.14935375e+00 4.77760060e+00 2.89863822 0.95720250 571.50 -4.99743405e+00 1.12428203e+00 5.12233904e+00 2.92030500 0.95491003 571.75 -5.47666683e+00 1.26687501e+00 5.62128560e+00 2.91426879 0.96949635 572.00 -5.69997458e+00 1.40427899e+00 5.87040967e+00 2.90003730 0.96532014 572.25 -6.08748286e+00 1.66000194e+00 6.30975864e+00 2.87537434 0.96798167 572.50 -6.42945090e+00 2.25251801e+00 6.81261156e+00 2.80461162 0.96684813 572.75 -6.92004200e+00 2.78392820e+00 7.45903730e+00 2.75910568 0.97310709 573.00 -7.42149472e+00 3.25100385e+00 8.10232127e+00 2.72871862 0.96772834 573.25 -7.72148486e+00 3.88430252e+00 8.64344460e+00 2.67550703 0.96280989 573.50 -7.56698796e+00 4.45667123e+00 8.78186912e+00 2.60932858 0.96498973 573.75 -7.56299162e+00 4.61821489e+00 8.86153209e+00 2.59339118 0.96995479 574.00 -8.27431995e+00 5.01846825e+00 9.67726171e+00 2.59639921 0.95725012 574.25 -8.94369184e+00 5.16091198e+00 1.03259206e+01 2.61822292 0.95162855 574.50 -9.79034566e+00 5.93654317e+00 1.14496032e+01 2.59650464 0.93366863 574.75 -1.06569663e+01 6.61222536e+00 1.25416289e+01 2.58626445 0.93101362 575.00 -1.20140454e+01 7.62960259e+00 1.42319403e+01 2.57579407 0.88384534 575.25 -1.29482307e+01 9.41727059e+00 1.60106735e+01 2.51277740 0.90188298 575.50 -1.23858510e+01 1.19245764e+01 1.71931623e+01 2.37516657 0.81150832 575.75 -1.17680662e+01 1.48255183e+01 1.89283749e+01 2.24172753 0.83109491 576.00 -1.21723394e+01 1.53679451e+01 1.96045806e+01 2.24067721 0.86508339 576.25 -1.25552293e+01 1.66649586e+01 2.08651534e+01 2.21646412 0.86738448 576.50 -1.37839928e+01 1.66857550e+01 2.16428482e+01 2.26124664 0.87038442 576.75 -1.48542546e+01 1.71138637e+01 2.26612711e+01 2.28562865 0.87759453 577.00 -1.96166161e+01 1.77063541e+01 2.64258700e+01 2.40733181 0.87339520 577.25 -2.24579964e+01 1.61537437e+01 2.76641471e+01 2.51803937 0.83571515 577.50 -2.61315661e+01 1.14236966e+01 2.85194599e+01 2.72946695 0.71868620 577.75 -2.81219577e+01 9.18194665e+00 2.95829791e+01 2.82600056 0.64869014 578.00 -2.89263051e+01 -4.53992950e+00 2.92804045e+01 -2.98591449 0.52499538 578.25 -2.55440600e+01 -1.39450555e+01 2.91026386e+01 -2.64188600 0.58799391 578.50 -1.43892575e+01 -2.14874838e+01 2.58604464e+01 -2.16086674 0.63642095 578.75 -1.04941634e+01 -2.37365411e+01 2.59528582e+01 -1.98706963 0.69200047 579.00 -8.79339973e+00 -2.69072235e+01 2.83076413e+01 -1.88665940 0.82912700 579.25 -7.53214892e+00 -2.56306589e+01 2.67144894e+01 -1.85662224 0.83042752 579.50 -7.18853623e+00 -2.06814806e+01 2.18951751e+01 -1.90531652 0.88411848 579.75 -6.94606720e+00 -1.84655250e+01 1.97287471e+01 -1.93058717 0.87179023 580.00 -5.67953223e+00 -1.65761120e+01 1.75221168e+01 -1.90089360 0.88924087 580.25 -5.62362102e+00 -1.52162380e+01 1.62221765e+01 -1.92480699 0.88266796 580.50 -5.84299982e+00 -1.18852295e+01 1.32438411e+01 -2.02771636 0.86084041 580.75 -5.57394148e+00 -1.00175153e+01 1.14638316e+01 -2.07855482 0.86918845 581.00 -6.34322067e+00 -8.44762138e+00 1.05640312e+01 -2.21486575 0.89870790 581.25 -6.04109929e+00 -6.91927883e+00 9.18538514e+00 -2.28853911 0.87201279 581.50 -5.21187627e+00 -5.37116069e+00 7.48418475e+00 -2.34114471 0.92047385 581.75 -4.67861308e+00 -4.22780579e+00 6.30585142e+00 -2.40676733 0.90164845 582.00 -3.77442174e+00 -3.12730746e+00 4.90166415e+00 -2.44968235 0.86907753 582.25 -2.70815241e+00 -2.55088929e+00 3.72036633e+00 -2.38608896 0.82905610 582.50 -1.78846510e+00 -2.17781137e+00 2.81806135e+00 -2.25834381 0.81529880 582.75 -1.08940651e+00 -2.01086241e+00 2.28700113e+00 -2.06729189 0.73751288 583.00 -3.95443510e-01 -1.90215635e+00 1.94282638e+00 -1.77576892 0.71694668 583.25 -1.79763972e-01 -2.13992248e+00 2.14745973e+00 -1.65460446 0.78479510 583.50 -5.30283147e-02 -2.21332035e+00 2.21395550e+00 -1.59475046 0.73471157 583.75 -3.09807137e-01 -1.84589851e+00 1.87171626e+00 -1.73708195 0.61501721 584.00 -6.67702028e-01 -1.54430422e+00 1.68246887e+00 -1.97888804 0.61633165 584.25 -9.74114500e-01 -1.08866313e+00 1.46085129e+00 -2.30072021 0.43692541 584.50 -1.07306799e+00 -5.56926742e-01 1.20898399e+00 -2.66285757 0.33587980 584.75 -7.24815629e-01 1.39514983e-01 7.38120672e-01 2.95143492 0.11407626 585.00 -5.11675341e-01 8.18739227e-01 9.65476865e-01 2.12936343 0.15109558 585.25 2.84134061e-01 1.85170104e+00 1.87337367e+00 1.41853901 0.27628524 585.50 1.68211415e+00 3.16120496e+00 3.58088325e+00 1.08179058 0.48885301 585.75 3.77888993e+00 2.62676937e+00 4.60216541e+00 0.60744103 0.52022783 586.00 4.72708932e+00 2.75586694e+00 5.47176169e+00 0.52782158 0.64642112 586.25 6.77864185e+00 2.02485690e+00 7.07460464e+00 0.29027408 0.69533480 586.50 8.17559480e+00 5.37823971e-01 8.19326583e+00 0.06568943 0.75460318 586.75 8.28690211e+00 -2.68667847e+00 8.71154336e+00 -0.31351523 0.76262681 587.00 7.42413619e+00 -4.32679322e+00 8.59295862e+00 -0.52767710 0.76339047 587.25 4.49598099e+00 -5.33673962e+00 6.97815411e+00 -0.87069689 0.62370642 587.50 2.88548993e+00 -5.51804237e+00 6.22694498e+00 -1.08898198 0.57230672 587.75 4.49800754e-01 -5.07901561e+00 5.09889403e+00 -1.48246615 0.43726544 588.00 -9.38771328e-01 -3.37093172e+00 3.49921024e+00 -1.84240441 0.27997405 588.25 -5.50560035e-01 1.14520975e+00 1.27067766e+00 2.01892600 0.04411298 588.50 7.88902603e-01 2.60877221e+00 2.72544671e+00 1.27713568 0.23789450 588.75 2.42412762e+00 3.14432096e+00 3.97028324e+00 0.91401882 0.49546141 589.00 3.96177674e+00 3.37718110e+00 5.20586469e+00 0.70590951 0.64355208 589.25 5.93339732e+00 2.87745256e+00 6.59431096e+00 0.45154231 0.82350274 589.50 6.74888145e+00 2.56052709e+00 7.21828926e+00 0.36262280 0.83277801 589.75 8.20006193e+00 1.18604338e+00 8.28539164e+00 0.14364219 0.83443301 590.00 9.09990532e+00 6.44119897e-01 9.12267325e+00 0.07066528 0.85303901 590.25 9.65839203e+00 -1.72283128e+00 9.81084523e+00 -0.17652006 0.86303150 590.50 9.53387343e+00 -3.61493900e+00 1.01962016e+01 -0.36241972 0.87789928 590.75 8.54188203e+00 -5.65427569e+00 1.02437582e+01 -0.58472822 0.84318386 591.00 7.31410738e+00 -6.15897725e+00 9.56186004e+00 -0.69987119 0.82884401 591.25 5.83578271e+00 -7.44614865e+00 9.46052269e+00 -0.90605410 0.86404830 591.50 4.74080870e+00 -7.10850530e+00 8.54436158e+00 -0.98261794 0.83210302 591.75 3.40817408e+00 -6.56258771e+00 7.39480953e+00 -1.09180152 0.86974930 592.00 2.50050286e+00 -5.98267526e+00 6.48420526e+00 -1.17490599 0.83900778 592.25 2.36332164e+00 -5.27006115e+00 5.77571066e+00 -1.14923802 0.86499061 592.50 2.44609430e+00 -5.06672918e+00 5.62628846e+00 -1.12102277 0.82073114 592.75 2.48357531e+00 -4.56243732e+00 5.19461073e+00 -1.07229915 0.76025739 593.00 2.55471780e+00 -4.56711952e+00 5.23308358e+00 -1.06078637 0.79516490 593.25 2.36479786e+00 -4.43744301e+00 5.02823721e+00 -1.08116160 0.79928455 593.50 2.12848647e+00 -3.42321350e+00 4.03098565e+00 -1.01451570 0.61270638 593.75 1.84178632e+00 -2.49156167e+00 3.09839577e+00 -0.93423691 0.51740535 594.00 2.20266141e+00 -2.48167408e+00 3.31819582e+00 -0.84489079 0.60960390 594.25 2.38034524e+00 -2.22512694e+00 3.25840964e+00 -0.75170790 0.62762351 594.50 3.27003971e+00 -1.98128670e+00 3.82343519e+00 -0.54473965 0.64389001 594.75 3.88308281e+00 -2.47147759e+00 4.60288318e+00 -0.56680710 0.78585388 595.00 3.87966216e+00 -3.15737764e+00 5.00208077e+00 -0.68311595 0.85641580 595.25 3.82339832e+00 -3.06902509e+00 4.90278388e+00 -0.67638245 0.87350244 595.50 4.22855913e+00 -2.34257748e+00 4.83408539e+00 -0.50590103 0.84492866 595.75 4.86223063e+00 -2.09742965e+00 5.29532793e+00 -0.40725530 0.82558735 596.00 7.05851504e+00 -2.50729496e+00 7.49060496e+00 -0.34131370 0.85375826 596.25 7.83055214e+00 -3.21181715e+00 8.46364674e+00 -0.38923834 0.88416390 596.50 7.62611791e+00 -4.95876003e+00 9.09653645e+00 -0.57653960 0.85717564 596.75 8.09998357e+00 -6.30150275e+00 1.02624885e+01 -0.66115974 0.84446744 597.00 7.83655192e+00 -8.19097483e+00 1.13359435e+01 -0.80750795 0.82396667 597.25 7.40042783e+00 -8.95050951e+00 1.16136968e+01 -0.87991647 0.81092652 597.50 4.50533413e+00 -1.20260240e+01 1.28422462e+01 -1.21234827 0.86497557 597.75 3.46213760e+00 -1.23648817e+01 1.28404321e+01 -1.29778982 0.90917919 598.00 2.22525550e+00 -1.27097948e+01 1.29031254e+01 -1.39747116 0.89112425 598.25 1.05261006e+00 -1.31258794e+01 1.31680180e+01 -1.49077409 0.90455075 598.50 -4.98739921e-01 -1.25350730e+01 1.25449909e+01 -1.61056291 0.90220836 598.75 -1.75918529e+00 -1.18614136e+01 1.19911578e+01 -1.71803462 0.85614133 599.00 -5.04878635e+00 -1.09263003e+01 1.20363732e+01 -2.00364755 0.88527964 599.25 -5.60518581e+00 -9.79434417e+00 1.12848255e+01 -2.09059009 0.90202100 599.50 -5.94979539e+00 -7.14391179e+00 9.29707163e+00 -2.26524834 0.89952673 599.75 -6.07221605e+00 -5.97899809e+00 8.52175017e+00 -2.36392949 0.91910101 600.00 -5.15804937e+00 -4.20590115e+00 6.65545474e+00 -2.45752853 0.89957574 600.25 -4.66640618e+00 -3.56557797e+00 5.87270746e+00 -2.48913156 0.90921317 600.50 -4.10118392e+00 -3.22014431e+00 5.21431097e+00 -2.47595736 0.91552649 600.75 -3.68825323e+00 -2.87799075e+00 4.67825210e+00 -2.47897199 0.91088671 601.00 -3.60385637e+00 -2.52986317e+00 4.40317935e+00 -2.52953385 0.95286015 601.25 -3.59905165e+00 -2.38670691e+00 4.31851163e+00 -2.55602943 0.93498633 601.50 -3.59176975e+00 -2.12572262e+00 4.17366824e+00 -2.60720102 0.88236647 601.75 -3.48042858e+00 -1.68993895e+00 3.86901496e+00 -2.68956781 0.84427413 602.00 -3.14673341e+00 -6.92249887e-01 3.22197782e+00 -2.92505189 0.79615336 602.25 -2.14556952e+00 2.92561178e-02 2.14576897e+00 3.12795790 0.51098255 602.50 -9.57324154e-01 5.88834150e-01 1.12391957e+00 2.59015621 0.27889207 602.75 -1.51310439e-01 3.91295828e-01 4.19532208e-01 1.93977674 0.05135361 603.00 9.11249615e-01 -2.65274506e-01 9.49076617e-01 -0.28328165 0.23402672 603.25 1.21125041e+00 -6.13837505e-01 1.35791165e+00 -0.46905690 0.45331021 603.50 1.49644476e+00 -6.11098595e-01 1.61641220e+00 -0.38769840 0.63158292 603.75 1.54170143e+00 -1.03746240e+00 1.85827112e+00 -0.59232858 0.66669739 604.00 1.71411804e+00 -1.42450995e+00 2.22877304e+00 -0.69338651 0.81543623 604.25 1.86621499e+00 -1.63270864e+00 2.47961608e+00 -0.71876035 0.82377682 604.50 2.03387869e+00 -1.70357207e+00 2.65307752e+00 -0.69724967 0.80344738 604.75 2.27523754e+00 -2.01406418e+00 3.03861159e+00 -0.72458376 0.83795916 605.00 2.29980526e+00 -2.20501345e+00 3.18609299e+00 -0.76435895 0.86008727 605.25 1.99778678e+00 -2.28142108e+00 3.03249636e+00 -0.85158332 0.73534386 605.50 2.11217959e+00 -2.44317788e+00 3.22961619e+00 -0.85793201 0.70190754 605.75 2.27694383e+00 -2.20577531e+00 3.17016055e+00 -0.76952330 0.69180100 606.00 2.53055269e+00 -1.95298084e+00 3.19653423e+00 -0.65728305 0.71445335 606.25 2.59219098e+00 -1.85272315e+00 3.18622616e+00 -0.62054527 0.57681393 606.50 2.43911033e+00 -2.22693965e+00 3.30280478e+00 -0.73995831 0.55564879 606.75 9.54988984e-01 -2.47200139e+00 2.65005563e+00 -1.20213649 0.46543295 607.00 4.60617575e-01 -2.45150959e+00 2.49440731e+00 -1.38507029 0.48412952 607.25 6.56818954e-01 -2.00969306e+00 2.11430304e+00 -1.25491421 0.44976733 607.50 8.99395935e-01 -1.58298675e+00 1.82064826e+00 -1.05411473 0.42952538 607.75 1.08828533e+00 -1.67924770e+00 2.00105917e+00 -0.99577267 0.56252095 608.00 1.33860001e+00 -1.76638980e+00 2.21629937e+00 -0.92231116 0.57853368 608.25 2.06890262e+00 -9.86990630e-01 2.29227148e+00 -0.44512775 0.63424144 608.50 2.28541202e+00 -5.53634438e-01 2.35151424e+00 -0.23766861 0.69893517 608.75 2.79836396e+00 9.30238223e-02 2.79990969e+00 0.03322998 0.68441925 609.00 2.91231384e+00 6.73918773e-01 2.98927055e+00 0.22740069 0.62355072 609.25 2.00599975e+00 2.34019660e+00 3.08229705e+00 0.86214125 0.34278753 609.50 3.85934599e-01 2.34831235e+00 2.37981436e+00 1.40790692 0.15684400 609.75 -3.25694486e+00 1.65825244e-01 3.26116357e+00 3.09072223 0.30201977 610.00 -3.57993164e+00 -1.17151534e+00 3.76674379e+00 -2.82533142 0.46554333 610.25 -2.82358006e+00 -3.35974384e+00 4.38867669e+00 -2.26969958 0.73056005 610.50 -2.54601416e+00 -3.87443754e+00 4.63610336e+00 -2.15216844 0.85418281 610.75 -1.72894546e+00 -3.91352436e+00 4.27842556e+00 -1.98679964 0.89524355 611.00 -1.40741274e+00 -4.32810104e+00 4.55118328e+00 -1.88519120 0.92983669 611.25 -1.31820640e+00 -4.73574097e+00 4.91578179e+00 -1.84227686 0.96871778 611.50 -1.22093502e+00 -4.88918714e+00 5.03932865e+00 -1.81551283 0.96683264 611.75 -1.21314955e+00 -5.20121885e+00 5.34082478e+00 -1.79994289 0.97258762 612.00 -1.27839615e+00 -5.32465246e+00 5.47596754e+00 -1.80642647 0.96909984 612.25 -1.59552750e+00 -5.47845854e+00 5.70606835e+00 -1.85419402 0.96338225 612.50 -1.95231927e+00 -5.38154891e+00 5.72473748e+00 -1.91881093 0.95986356 612.75 -2.49502591e+00 -5.16954186e+00 5.74014959e+00 -2.02045946 0.96855033 613.00 -2.72457694e+00 -4.85527773e+00 5.56749866e+00 -2.08216560 0.96458217 613.25 -2.94897840e+00 -4.32467878e+00 5.23443599e+00 -2.16926790 0.97194634 613.50 -2.89601495e+00 -3.92218703e+00 4.87549522e+00 -2.20681089 0.97163629 613.75 -2.82491508e+00 -3.61355653e+00 4.58671298e+00 -2.23431270 0.98005767 614.00 -2.84192165e+00 -3.27592971e+00 4.33684611e+00 -2.28537188 0.98164416 614.25 -2.80791847e+00 -2.88942379e+00 4.02904157e+00 -2.34188962 0.97935534 614.50 -2.61921394e+00 -2.51698819e+00 3.63256262e+00 -2.37609485 0.97153577 614.75 -2.36493122e+00 -2.26043416e+00 3.27146179e+00 -2.37878282 0.97003900 615.00 -1.91951419e+00 -2.10747908e+00 2.85061446e+00 -2.30955211 0.94812624 615.25 -1.58073335e+00 -2.04676700e+00 2.58611158e+00 -2.22842200 0.95924685 615.50 -1.17719416e+00 -2.00048310e+00 2.32114599e+00 -2.10268356 0.95615042 615.75 -9.86057249e-01 -2.02784747e+00 2.25487788e+00 -2.02339010 0.97352375 616.00 -8.25590546e-01 -2.17337973e+00 2.32490413e+00 -1.93382523 0.96793506 616.25 -7.40620367e-01 -2.30048829e+00 2.41676745e+00 -1.88225854 0.96811121 616.50 -6.64014504e-01 -2.42918687e+00 2.51830580e+00 -1.83762647 0.95855933 616.75 -5.26924937e-01 -2.48789717e+00 2.54308517e+00 -1.77950737 0.95505429 617.00 -4.02063496e-01 -2.56791195e+00 2.59919735e+00 -1.72610753 0.95414630 617.25 -2.36083815e-01 -2.65641393e+00 2.66688405e+00 -1.65943657 0.95067208 617.50 -9.66108814e-02 -2.85515255e+00 2.85678662e+00 -1.60462080 0.95481597 617.75 -8.74615855e-02 -2.94782035e+00 2.94911755e+00 -1.60045754 0.96262421 618.00 -2.59416074e-01 -3.12649325e+00 3.13723712e+00 -1.65358019 0.93835391 618.25 -3.98932117e-01 -3.33503648e+00 3.35881157e+00 -1.68984917 0.94082314 618.50 -6.29777364e-01 -3.59883185e+00 3.65352025e+00 -1.74403708 0.94026485 618.75 -7.70521675e-01 -3.73959742e+00 3.81815302e+00 -1.77399663 0.94393013 619.00 -1.01561123e+00 -3.51072303e+00 3.65467405e+00 -1.85239717 0.93381293 619.25 -1.09945540e+00 -3.33059618e+00 3.50737411e+00 -1.88964100 0.93132969 619.50 -1.19811581e+00 -3.27964612e+00 3.49164147e+00 -1.92105232 0.87301475 619.75 -1.34644170e+00 -3.25309886e+00 3.52073252e+00 -1.96322356 0.83832446 620.00 -1.88903400e+00 -3.40554619e+00 3.89437984e+00 -2.07723577 0.87107426 620.25 -2.14614999e+00 -3.09801752e+00 3.76877597e+00 -2.17663957 0.87375795 620.50 -2.24046723e+00 -2.59571333e+00 3.42890961e+00 -2.28287026 0.88905391 620.75 -2.21476134e+00 -2.35003485e+00 3.22921532e+00 -2.32656908 0.89329975 621.00 -1.81009976e+00 -1.93936675e+00 2.65284839e+00 -2.32173204 0.87236218 621.25 -1.41106233e+00 -2.00018269e+00 2.44782100e+00 -2.18518182 0.88983558 621.50 -1.09296251e+00 -2.07236745e+00 2.34291995e+00 -2.05612136 0.94078050 621.75 -9.60175607e-01 -2.16802911e+00 2.37113631e+00 -1.98771307 0.94584202 622.00 -8.26145629e-01 -2.22730299e+00 2.37558313e+00 -1.92598301 0.94767185 622.25 -7.48400056e-01 -2.25634520e+00 2.37722449e+00 -1.89106432 0.92985097 622.50 -7.10875494e-01 -2.44238111e+00 2.54373140e+00 -1.85402975 0.89980342 622.75 -7.55432670e-01 -2.53874705e+00 2.64875728e+00 -1.86001421 0.88078771 623.00 -6.45699079e-01 -2.69664174e+00 2.77286927e+00 -1.80581706 0.90855621 623.25 -7.01338124e-01 -2.76680730e+00 2.85431214e+00 -1.81905025 0.86610325 623.50 -7.46289957e-01 -3.06477626e+00 3.15433071e+00 -1.80965327 0.82473059 623.75 -7.87208610e-01 -3.08376786e+00 3.18265952e+00 -1.82073343 0.73377365 624.00 -8.33863730e-01 -3.29155608e+00 3.39553680e+00 -1.81891059 0.66619896 624.25 -1.37947508e+00 -3.00303227e+00 3.30471698e+00 -2.00140731 0.62544166 624.50 -2.05216331e+00 -2.52948987e+00 3.25725241e+00 -2.25238681 0.58422535 624.75 -2.44187487e+00 -1.95190748e+00 3.12613110e+00 -2.46724948 0.56975474 625.00 -2.90595144e+00 -1.40084255e+00 3.22597484e+00 -2.69239988 0.58080063 625.25 -3.03932693e+00 -9.08448916e-01 3.17218972e+00 -2.85114712 0.58926151 625.50 -3.10935748e+00 -4.70341231e-01 3.14472969e+00 -2.99146443 0.62391425 625.75 -2.84100798e+00 -2.68146817e-01 2.85363436e+00 -3.04748704 0.72051082 626.00 -3.03516952e+00 -2.34091135e-01 3.04418341e+00 -3.06461882 0.82652080 626.25 -2.78495799e+00 -4.89514350e-02 2.78538817e+00 -3.12401738 0.84182224 626.50 -2.62515136e+00 1.43292920e-01 2.62905925e+00 3.08706214 0.85612492 626.75 -2.38626490e+00 3.84485781e-01 2.41704148e+00 2.98184114 0.85257170 627.00 -2.36313135e+00 4.75973000e-01 2.41058915e+00 2.94283571 0.88319045 627.25 -2.13576594e+00 6.38373624e-01 2.22912921e+00 2.85114827 0.90437513 627.50 -2.07134813e+00 7.50422570e-01 2.20309263e+00 2.79401391 0.89874330 627.75 -1.76017867e+00 9.78929072e-01 2.01408319e+00 2.63403754 0.84128418 628.00 -1.61940435e+00 1.11824607e+00 1.96797986e+00 2.53725122 0.83791419 628.25 -1.17251549e+00 1.18474156e+00 1.66685487e+00 2.35100797 0.81825713 628.50 -8.13845465e-01 1.25318408e+00 1.49426061e+00 2.14676520 0.83633418 628.75 -3.57146333e-01 1.21005246e+00 1.26165783e+00 1.85779717 0.83946695 629.00 -7.84954726e-02 1.05526348e+00 1.05817888e+00 1.64504430 0.81627623 629.25 1.51197130e-01 7.10458158e-01 7.26368616e-01 1.36110825 0.71700118 629.50 1.86953407e-01 4.78105245e-01 5.13357771e-01 1.19804670 0.58147155 629.75 3.06480192e-02 1.84678579e-01 1.87204377e-01 1.40634182 0.14131269 630.00 -7.84696904e-02 1.39350063e-01 1.59924771e-01 2.08365056 0.11457904 630.25 -2.62588232e-01 2.64198368e-01 3.72496117e-01 2.35313798 0.39988858 630.50 -2.64180618e-01 3.18600783e-01 4.13881454e-01 2.26308443 0.51075000 630.75 -2.08472216e-01 3.37144582e-01 3.96392651e-01 2.12459688 0.54308024 631.00 -1.15172253e-01 3.61600149e-01 3.79498769e-01 1.87914455 0.48262480 631.25 7.94411271e-02 4.84025427e-01 4.90501281e-01 1.40812072 0.59431824 631.50 1.12668106e-01 4.60838801e-01 4.74411744e-01 1.33101509 0.52724909 631.75 2.73180782e-01 3.42079829e-01 4.37774313e-01 0.89691707 0.42879469 632.00 2.98246387e-01 2.85600398e-01 4.12938851e-01 0.76374178 0.39149240 632.25 2.67939576e-01 5.93387154e-02 2.74431594e-01 0.21794538 0.17469353 632.50 2.02457017e-01 -9.88421879e-02 2.25296742e-01 -0.45417378 0.09418189 632.75 -6.76763388e-02 -2.97116190e-01 3.04726299e-01 -1.79475271 0.13678685 633.00 -2.66964047e-01 -3.41921818e-01 4.33797570e-01 -2.23370436 0.22058458 633.25 -2.92436093e-01 -4.21198411e-01 5.12764050e-01 -2.17768339 0.24050165 633.50 -4.95022039e-01 -2.07371004e-01 5.36702481e-01 -2.74488931 0.22933223 633.75 -7.96597180e-01 9.38285979e-02 8.02104029e-01 3.02434612 0.44577462 634.00 -8.08741777e-01 3.99821088e-01 9.02175241e-01 2.68245579 0.50084430 634.25 -9.32288838e-01 7.62588424e-01 1.20445157e+00 2.45598739 0.61623432 634.50 -1.01543977e+00 9.58549443e-01 1.39640071e+00 2.38500649 0.63237562 634.75 -7.83352618e-01 1.18756409e+00 1.42265589e+00 2.15391139 0.64718632 635.00 -6.70290591e-01 1.46030199e+00 1.60678915e+00 2.00111617 0.63545596 635.25 -2.63864730e-01 1.96612811e+00 1.98375512e+00 1.70420445 0.58737989 635.50 3.13562549e-01 1.39724307e+00 1.43199500e+00 1.35003860 0.39570898 635.75 1.04533639e+00 9.66974655e-01 1.42399725e+00 0.74647666 0.41558425 636.00 1.03627421e+00 2.08730141e-01 1.05708680e+00 0.19876409 0.21941740 636.25 6.71855497e-01 -1.03318542e+00 1.23242116e+00 -0.99422723 0.24884589 636.50 2.06948908e-01 -6.98211998e-01 7.28236119e-01 -1.28264703 0.07078319 636.75 -2.33167504e-01 -4.62505360e-01 5.17955880e-01 -2.03775054 0.02338891 637.00 -2.90998889e-01 6.00526069e-01 6.67316951e-01 2.02202657 0.01800199 637.25 -2.31958342e-02 1.72965490e+00 1.72981043e+00 1.58420619 0.07405076 637.50 5.04928787e-01 3.20304534e+00 3.24259966e+00 1.41444278 0.20759072 637.75 2.12917166e+00 4.94053686e+00 5.37980264e+00 1.16388872 0.46347360 638.00 3.26887661e+00 5.04161925e+00 6.00861706e+00 0.99556197 0.71718683 638.25 3.92509940e+00 5.08917402e+00 6.42698199e+00 0.91382424 0.84873136 638.50 3.90141490e+00 4.67868129e+00 6.09188779e+00 0.87574104 0.89029166 638.75 4.06497596e+00 4.48004627e+00 6.04936725e+00 0.83393453 0.90780423 639.00 4.24839906e+00 4.02202064e+00 5.85026022e+00 0.75803294 0.92133338 639.25 4.21775344e+00 3.81919180e+00 5.68996223e+00 0.73584757 0.95095130 639.50 4.08169283e+00 3.74514168e+00 5.53952187e+00 0.74242498 0.96491621 639.75 4.14576911e+00 3.63673927e+00 5.51482312e+00 0.72008428 0.96682818 640.00 4.32615954e+00 3.52657673e+00 5.58143349e+00 0.68392569 0.96594710 640.25 4.32216112e+00 3.54483141e+00 5.58989325e+00 0.68690885 0.97335236 640.50 4.20651131e+00 3.59877969e+00 5.53587867e+00 0.70769344 0.97708903 640.75 4.23544004e+00 3.65104726e+00 5.59187790e+00 0.71143283 0.97748158 641.00 4.18335983e+00 4.01707157e+00 5.79977270e+00 0.76512295 0.97492962 641.25 4.31911777e+00 4.16625854e+00 6.00104062e+00 0.76738568 0.97506424 641.50 4.69470182e+00 4.30420535e+00 6.36917647e+00 0.74203160 0.97969568 641.75 4.98600520e+00 4.45181715e+00 6.68422948e+00 0.72885772 0.97563802 642.00 5.58359406e+00 4.80251291e+00 7.36482538e+00 0.71033504 0.97736385 642.25 5.82843467e+00 4.79646325e+00 7.54829188e+00 0.68857422 0.97387015 642.50 5.94881772e+00 4.57003088e+00 7.50157413e+00 0.65506348 0.97499687 642.75 6.00444900e+00 4.52547551e+00 7.51886536e+00 0.64585665 0.96958957 643.00 6.34313925e+00 4.52372003e+00 7.79098572e+00 0.61950858 0.96133500 643.25 6.23406331e+00 4.84303888e+00 7.89421123e+00 0.66047552 0.94700200 643.50 6.02716800e+00 5.26213582e+00 8.00105165e+00 0.71773550 0.95573587 643.75 6.04753875e+00 5.56931403e+00 8.22131277e+00 0.74425493 0.93769636 644.00 5.62500156e+00 6.49050394e+00 8.58878827e+00 0.85671459 0.92754299 644.25 5.22996720e+00 7.42827824e+00 9.08470552e+00 0.95734950 0.87797082 644.50 4.99862910e+00 9.46120750e+00 1.07005019e+01 1.08474330 0.88049087 644.75 4.59775380e+00 1.09388834e+01 1.18658548e+01 1.17290239 0.83689579 645.00 5.09256368e+00 1.43812704e+01 1.52563149e+01 1.23046400 0.77013067 645.25 6.84757525e+00 1.60647107e+01 1.74632247e+01 1.16786780 0.58068909 645.50 1.72585133e+01 1.41032116e+01 2.22880430e+01 0.68512563 0.52195909 645.75 2.02648138e+01 1.04245700e+01 2.27889082e+01 0.47511478 0.54070190 646.00 2.44933043e+01 1.00295483e+01 2.64672211e+01 0.38865303 0.50597781 646.25 2.17947273e+01 3.18664410e+00 2.20264577e+01 0.14518296 0.35283478 646.50 2.49876288e+01 -5.13544577e+00 2.55098882e+01 -0.20269713 0.33352487 646.75 1.38121141e+01 -1.13827622e+01 1.78980941e+01 -0.68927287 0.16846091 647.00 6.96432289e+00 -1.91684713e+01 2.03944131e+01 -1.22230321 0.21711823 647.25 4.64392521e+00 -2.19364029e+01 2.24225737e+01 -1.36217699 0.34721872 647.50 -4.41625325e-01 -2.56807114e+01 2.56845083e+01 -1.58799140 0.48746707 647.75 -5.01509818e+00 -2.31988696e+01 2.37347585e+01 -1.78369870 0.61849701 648.00 -8.21580535e+00 -2.24828312e+01 2.39369413e+01 -1.92114682 0.74011253 648.25 -9.42862751e+00 -1.61495298e+01 1.87004366e+01 -2.09924346 0.75794979 648.50 -8.95532659e+00 -1.47234395e+01 1.72330364e+01 -2.11724974 0.81230420 648.75 -7.35208867e+00 -1.14512974e+01 1.36082850e+01 -2.14154907 0.81009933 649.00 -7.46876095e+00 -1.04475755e+01 1.28426720e+01 -2.19143910 0.87713877 649.25 -5.50972433e+00 -8.84899410e+00 1.04240951e+01 -2.12769568 0.88978453 649.50 -5.30182223e+00 -7.97997932e+00 9.58067790e+00 -2.15722145 0.93019137 649.75 -3.84348784e+00 -6.99195021e+00 7.97870707e+00 -2.07341059 0.92310479 650.00 -3.32933923e+00 -6.46113758e+00 7.26847980e+00 -2.04659849 0.92700993 650.25 -2.09505182e+00 -4.91550268e+00 5.34335183e+00 -1.97369406 0.89444279 650.50 -1.43982444e+00 -4.49052372e+00 4.71570755e+00 -1.88107627 0.91560613 650.75 -5.37295040e-01 -3.76402401e+00 3.80217868e+00 -1.71258333 0.88341336 651.00 1.24308602e-01 -3.59710302e+00 3.59925031e+00 -1.53625210 0.86704860 651.25 1.24284002e+00 -4.04452442e+00 4.23117348e+00 -1.27266538 0.91963460 651.50 1.64398540e+00 -4.19589703e+00 4.50646645e+00 -1.19737203 0.93985056 651.75 1.60065959e+00 -4.74079643e+00 5.00372480e+00 -1.24517913 0.92716315 652.00 1.19856357e+00 -4.74016069e+00 4.88934331e+00 -1.32313435 0.90244533 652.25 5.68792929e-01 -3.46669434e+00 3.51304641e+00 -1.40817171 0.77172342 652.50 5.19843355e-01 -1.93755256e+00 2.00607753e+00 -1.30867062 0.47599220 652.75 1.06827423e+00 -3.04454778e-02 1.06870798e+00 -0.02849197 0.23969368 653.00 2.33005634e+00 7.27145696e-01 2.44088169e+00 0.30249504 0.55231617 653.25 4.97764009e+00 1.67016439e+00 5.25036665e+00 0.32372928 0.81736650 653.50 6.60078685e+00 3.08248228e-01 6.60798032e+00 0.04666481 0.78463925 653.75 8.07280155e+00 -2.82597732e+00 8.55314402e+00 -0.33672964 0.88932313 654.00 6.98085191e+00 -4.65810733e+00 8.39227367e+00 -0.58841961 0.87910130 654.25 5.04189594e+00 -6.04826335e+00 7.87414784e+00 -0.87589449 0.93996870 654.50 3.51404021e+00 -5.34403728e+00 6.39587469e+00 -0.98912290 0.88650461 654.75 1.93739505e+00 -4.42103048e+00 4.82690481e+00 -1.15777962 0.93882992 655.00 1.25628330e+00 -3.92628260e+00 4.12237101e+00 -1.26112276 0.86749377 655.25 1.60053082e-01 -3.14949931e+00 3.15356352e+00 -1.52002143 0.81100006 655.50 -7.84626759e-01 -2.37902394e+00 2.50507366e+00 -1.88937287 0.57414874 655.75 -1.71993574e+00 -9.56104660e-01 1.96781987e+00 -2.63423436 0.42213549 656.00 -1.58074680e+00 6.30297768e-01 1.70177428e+00 2.76217798 0.31655172 656.25 -1.58128499e+00 1.42766954e+00 2.13042308e+00 2.40720297 0.59087751 656.50 -1.91820848e+00 1.75824325e+00 2.60210359e+00 2.39967783 0.59020942 656.75 -2.38974560e+00 2.18489462e+00 3.23800070e+00 2.40094429 0.74410707 657.00 -3.04859537e+00 2.63040802e+00 4.02653450e+00 2.42969928 0.75719249 657.25 -3.89207477e+00 2.72659166e+00 4.75210986e+00 2.53049789 0.77757646 657.50 -5.09276452e+00 4.12111737e+00 6.55132497e+00 2.46126087 0.75690723 657.75 -5.63260485e+00 5.37321052e+00 7.78444787e+00 2.37975897 0.78036884 658.00 -6.30272352e+00 8.53923980e+00 1.06133378e+01 2.20663106 0.78334100 658.25 -6.31757821e+00 1.06546623e+01 1.23868327e+01 2.10600867 0.86959867 658.50 -4.51850115e+00 1.25517913e+01 1.33403268e+01 1.91634177 0.90914794 658.75 -3.65997256e+00 1.38742412e+01 1.43488664e+01 1.82871694 0.92707436 659.00 -2.56070405e+00 1.48550846e+01 1.50741747e+01 1.74149771 0.93925325 659.25 -1.89264573e+00 1.55972679e+01 1.57116795e+01 1.69155065 0.92632511 659.50 -1.32716124e+00 1.63971715e+01 1.64507930e+01 1.65155870 0.89954642 659.75 -1.04892457e+00 1.65955538e+01 1.66286695e+01 1.63391752 0.89383889 660.00 9.21589720e-01 1.64654063e+01 1.64911774e+01 1.51488339 0.85372329 660.25 1.07650792e+00 1.67644253e+01 1.67989531e+01 1.50667054 0.84581166 660.50 4.00361027e+00 1.66837131e+01 1.71573651e+01 1.33527860 0.83253628 660.75 4.79140217e+00 1.69037509e+01 1.75696992e+01 1.29458945 0.84660903 661.00 6.94066321e+00 1.78210422e+01 1.91249144e+01 1.19940515 0.84784326 661.25 7.81297374e+00 1.70652789e+01 1.87687587e+01 1.14145119 0.83830061 661.50 8.02674713e+00 1.63425218e+01 1.82073252e+01 1.11424796 0.84383586 661.75 9.26138845e+00 1.59952648e+01 1.84830141e+01 1.04595504 0.87049005 662.00 1.40326118e+01 1.48629484e+01 2.04406808e+01 0.81412604 0.86862323 662.25 1.52033566e+01 1.38082726e+01 2.05380243e+01 0.73734812 0.88834560 662.50 1.66689995e+01 8.78069701e+00 1.88402809e+01 0.48483205 0.85405354 662.75 1.65754862e+01 6.18858294e+00 1.76930863e+01 0.35732994 0.87811862 663.00 1.49647859e+01 3.18845091e+00 1.53006875e+01 0.20992456 0.92020015 663.25 1.33397415e+01 1.71375280e+00 1.34493736e+01 0.12776986 0.91607577 663.50 1.16001920e+01 9.26220192e-01 1.16371104e+01 0.07967621 0.92894341 663.75 1.07049608e+01 6.22272536e-01 1.07230317e+01 0.05806402 0.89860716 664.00 9.18370201e+00 -4.81001923e-01 9.19628977e+00 -0.05232779 0.86191991 664.25 8.52093013e+00 -7.46385816e-01 8.55355727e+00 -0.08737140 0.80584066 664.50 7.49304710e+00 -1.70286586e+00 7.68410743e+00 -0.22346399 0.63618282 664.75 7.61681740e+00 -1.40901955e+00 7.74604696e+00 -0.18292013 0.51933575 665.00 9.61372288e+00 -2.88365684e-01 9.61804670e+00 -0.02998622 0.54275282 665.25 9.95926681e+00 2.63940528e+00 1.03030799e+01 0.25906446 0.64935556 665.50 9.69531309e+00 3.37596195e+00 1.02662659e+01 0.33507532 0.85791831 665.75 7.92520976e+00 2.13046195e+00 8.20657162e+00 0.26261252 0.83592187 666.00 6.49254549e+00 2.45623042e+00 6.94162912e+00 0.36167421 0.88744051 666.25 6.27089808e+00 2.97281892e+00 6.93987140e+00 0.44268592 0.89834886 666.50 6.39019400e+00 3.18162366e+00 7.13843879e+00 0.46195944 0.90908165 666.75 7.19413151e+00 2.62835724e+00 7.65922907e+00 0.35028138 0.90602887 667.00 7.30962189e+00 2.17013350e+00 7.62496240e+00 0.28859862 0.90281134 667.25 7.62490818e+00 7.46736037e-01 7.66138626e+00 0.09762247 0.91333063 667.50 7.83360591e+00 -2.59232915e-01 7.83789406e+00 -0.03308034 0.93370429 667.75 7.00966091e+00 -1.38843786e+00 7.14584535e+00 -0.19554382 0.87595737 668.00 6.69570105e+00 -2.79799579e+00 7.25680322e+00 -0.39582404 0.87976509 668.25 6.12492845e+00 -4.15560990e+00 7.40161078e+00 -0.59613301 0.87109393 668.50 6.10729988e+00 -5.31992857e+00 8.09942910e+00 -0.71660381 0.92532481 668.75 4.65844103e+00 -6.78334604e+00 8.22890371e+00 -0.96902063 0.89831872 669.00 3.40109903e+00 -7.66288304e+00 8.38374922e+00 -1.15307630 0.89999708 669.25 1.42905239e+00 -8.91006891e+00 9.02394141e+00 -1.41176449 0.80288971 669.50 -3.38717572e-01 -9.25804952e+00 9.26424366e+00 -1.60736629 0.75836236 669.75 -5.12233977e+00 -8.05339477e+00 9.54439794e+00 -2.13730033 0.65531542 670.00 -7.62854728e+00 -5.58878286e+00 9.45670278e+00 -2.50931155 0.69616653 670.25 -6.90944367e+00 -2.06117283e+00 7.21032907e+00 -2.85168482 0.64309673 670.50 -6.68899864e+00 -1.39108127e+00 6.83211606e+00 -2.93654978 0.76840633 670.75 -6.94633939e+00 -1.68243480e+00 7.14718250e+00 -2.90396426 0.89125246 671.00 -6.88541152e+00 -1.36520249e+00 7.01944938e+00 -2.94585664 0.89008833 671.25 -7.42245273e+00 -3.22018332e-01 7.42943472e+00 -3.09823549 0.92550021 671.50 -7.55421412e+00 -2.26284937e-01 7.55760252e+00 -3.11164681 0.95164112 671.75 -7.55031387e+00 3.66727258e-01 7.55921481e+00 3.09305967 0.96714133 672.00 -7.64470232e+00 6.87503951e-01 7.67555440e+00 3.05190186 0.97220589 672.25 -7.45775312e+00 9.11823052e-01 7.51328842e+00 3.01993137 0.97415712 672.50 -7.21374702e+00 1.15697828e+00 7.30593901e+00 2.98256183 0.96484796 672.75 -6.41925633e+00 1.21854622e+00 6.53388910e+00 2.95399798 0.94008220 673.00 -6.28528912e+00 9.08387312e-01 6.35059264e+00 2.99806056 0.92945581 673.25 -6.97840323e+00 3.05460259e-01 6.98508537e+00 3.09784835 0.91638449 673.50 -7.40217208e+00 2.21900343e-01 7.40549737e+00 3.11162390 0.91844793 673.75 -7.82060732e+00 8.64407908e-01 7.86823359e+00 3.03150998 0.93147879 674.00 -8.03422149e+00 9.77328096e-01 8.09344705e+00 3.02054176 0.93296883 674.25 -8.60790819e+00 9.73897166e-01 8.66282628e+00 3.02893191 0.91703632 674.50 -8.53768501e+00 7.72581910e-01 8.57256952e+00 3.05134765 0.89714929 674.75 -8.42457591e+00 7.84184546e-01 8.46099431e+00 3.04877713 0.89940209 675.00 -9.04399157e+00 3.68613374e-01 9.05150039e+00 3.10085738 0.90696972 675.25 -1.01473486e+01 2.28742408e-01 1.01499264e+01 3.11905438 0.91070453 675.50 -1.11784130e+01 5.50541307e-01 1.11919620e+01 3.09238202 0.92367458 675.75 -1.20213237e+01 1.44193169e+00 1.21074932e+01 3.02221516 0.92993633 676.00 -1.25007918e+01 2.21846551e+00 1.26961169e+01 2.96595527 0.92977723 676.25 -1.32314549e+01 3.33210449e+00 1.36445711e+01 2.89489045 0.94981123 676.50 -1.35508611e+01 4.93706567e+00 1.44222208e+01 2.79220392 0.95785642 676.75 -1.35940717e+01 6.49095620e+00 1.50642391e+01 2.69611928 0.96955720 677.00 -1.26638552e+01 7.24383865e+00 1.45892573e+01 2.62200913 0.95983036 677.25 -1.14580223e+01 7.70783189e+00 1.38093066e+01 2.54942353 0.96912776 677.50 -1.11415535e+01 8.02297760e+00 1.37296170e+01 2.51750700 0.96970066 677.75 -1.08948362e+01 8.41583078e+00 1.37667594e+01 2.48387110 0.97737887 678.00 -1.07592006e+01 8.96354603e+00 1.40037693e+01 2.44698902 0.97472428 678.25 -1.05185409e+01 9.24652587e+00 1.40049257e+01 2.42046259 0.97142898 678.50 -9.49247257e+00 9.80648270e+00 1.36482284e+01 2.33992509 0.96250069 678.75 -9.18129486e+00 1.05230008e+01 1.39653042e+01 2.28820738 0.96006079 679.00 -8.37899975e+00 1.14089097e+01 1.41552413e+01 2.20425533 0.96407567 679.25 -8.00385511e+00 1.16410616e+01 1.41271375e+01 2.17312014 0.97349148 679.50 -7.57797272e+00 1.21999231e+01 1.43618868e+01 2.12662175 0.97421701 679.75 -7.01818068e+00 1.25112042e+01 1.43452114e+01 2.08200882 0.97103801 680.00 -5.69416761e+00 1.34251429e+01 1.45827983e+01 1.97194006 0.96277887 680.25 -4.73839798e+00 1.35385133e+01 1.43437707e+01 1.90746577 0.96351494 680.50 -3.37791390e+00 1.21841565e+01 1.26437325e+01 1.84124220 0.91056898 680.75 -1.77549104e+00 1.14453964e+01 1.15822911e+01 1.72469673 0.89669000 681.00 -6.91641039e-01 1.03555536e+01 1.03786251e+01 1.63748666 0.94144389 681.25 -4.53390855e-01 1.04280659e+01 1.04379175e+01 1.61424691 0.95352179 681.50 -6.55991484e-01 1.02845161e+01 1.03054159e+01 1.63449442 0.94865245 681.75 -9.66614051e-01 1.02972629e+01 1.03425319e+01 1.66439302 0.93529399 682.00 -8.43429806e-01 1.01154446e+01 1.01505465e+01 1.65398430 0.92009265 682.25 -7.65471905e-01 1.06298813e+01 1.06574070e+01 1.64268357 0.93042757 682.50 -5.88039440e-01 1.08103048e+01 1.08262865e+01 1.62513896 0.90532813 682.75 4.33369590e-02 1.08520794e+01 1.08521659e+01 1.56680292 0.91439037 683.00 3.44868480e-01 1.04453180e+01 1.04510096e+01 1.53779175 0.94696130 683.25 -4.43246571e-02 1.08075953e+01 1.08076862e+01 1.57489755 0.94467357 683.50 1.32658637e+00 1.16537300e+01 1.17289920e+01 1.45745060 0.90477810 683.75 2.71036370e+00 1.16257654e+01 1.19375246e+01 1.34175324 0.88531119 684.00 3.85066578e+00 1.12671220e+01 1.19069586e+01 1.24147991 0.90234104 684.25 4.36813291e+00 1.12336871e+01 1.20530623e+01 1.19994549 0.86787793 684.50 5.17475048e+00 1.09067527e+01 1.20720875e+01 1.12779372 0.81554131 684.75 6.92058524e+00 9.90872101e+00 1.20862423e+01 0.96112231 0.85061962 685.00 8.65539290e+00 7.73648998e+00 1.16090096e+01 0.72939836 0.87822197 685.25 8.02209829e+00 6.95617875e+00 1.06180264e+01 0.71435357 0.84568948 685.50 7.70350070e+00 6.57563230e+00 1.01283199e+01 0.70657464 0.88084995 685.75 8.21302172e+00 6.31820334e+00 1.03621146e+01 0.65573344 0.88877390 686.00 9.11479803e+00 5.75643171e+00 1.07803548e+01 0.56329408 0.89438572 686.25 9.57546003e+00 5.16831643e+00 1.08812191e+01 0.49493660 0.89222429 686.50 1.01500163e+01 4.48212501e+00 1.10955971e+01 0.41583649 0.93493348 686.75 1.05709829e+01 3.62367843e+00 1.11748255e+01 0.33024161 0.93043945 687.00 1.10942381e+01 2.66785271e+00 1.14105021e+01 0.23599115 0.95450466 687.25 1.14016784e+01 1.62341626e+00 1.15166727e+01 0.14143332 0.94921313 687.50 1.18835589e+01 4.75348507e-01 1.18930622e+01 0.03997920 0.96752532 687.75 1.17017991e+01 -4.99135346e-01 1.17124395e+01 -0.04262874 0.96471435 688.00 1.14814084e+01 -1.66378885e+00 1.16013332e+01 -0.14390981 0.96444873 688.25 1.07531814e+01 -3.38657271e+00 1.12738541e+01 -0.30510334 0.94375741 688.50 9.85311756e+00 -4.59088512e+00 1.08701496e+01 -0.43602390 0.96528757 688.75 8.68931580e+00 -4.97600204e+00 1.00132315e+01 -0.52007206 0.95665301 689.00 7.97432357e+00 -5.18954294e+00 9.51426257e+00 -0.57692447 0.95475995 689.25 7.09324533e+00 -4.50285091e+00 8.40177336e+00 -0.56562139 0.92992510 689.50 7.01934846e+00 -4.04167818e+00 8.09977872e+00 -0.52242859 0.92404354 689.75 7.29518889e+00 -3.44513000e+00 8.06775691e+00 -0.44119962 0.79528066 690.00 5.65411502e+00 -2.58272370e+00 6.21606615e+00 -0.42848327 0.45960088 690.25 -3.30210114e-01 -2.51403985e+00 2.53563307e+00 -1.70139514 0.26455764 690.50 -2.79076636e-01 -3.09981143e+00 3.11234874e+00 -1.66058446 0.60684618 690.75 6.65802540e-01 -2.74412705e+00 2.82374331e+00 -1.33276779 0.76626319 691.00 1.10040864e+00 -2.75295149e+00 2.96473289e+00 -1.19053171 0.83514174 691.25 1.64730433e+00 -2.44795376e+00 2.95060827e+00 -0.97846930 0.83569747 691.50 1.88395025e+00 -2.27721220e+00 2.95549724e+00 -0.87962600 0.84917440 691.75 2.69412448e+00 -1.78139576e+00 3.22981077e+00 -0.58421893 0.82763319 692.00 3.02555597e+00 -1.72052696e+00 3.48054622e+00 -0.51706012 0.86472912 692.25 3.09165343e+00 -1.44329024e+00 3.41195071e+00 -0.43676491 0.81782664 692.50 3.14896495e+00 -1.42795536e+00 3.45760565e+00 -0.42573431 0.77987116 692.75 3.69129469e+00 -1.78524126e+00 4.10033448e+00 -0.45047054 0.73221378 693.00 3.88752856e+00 -1.78258966e+00 4.27673991e+00 -0.42993355 0.66529791 693.25 4.29261109e+00 -1.60593977e+00 4.58318148e+00 -0.35799651 0.59565505 693.50 4.85044232e+00 -1.94269412e+00 5.22502164e+00 -0.38095368 0.65282398 693.75 4.86600007e+00 -3.53762918e+00 6.01604329e+00 -0.62862422 0.72877703 694.00 4.80311928e+00 -3.78620450e+00 6.11598720e+00 -0.66755384 0.67129827 694.25 4.13879288e+00 -4.39296679e+00 6.03554171e+00 -0.81518085 0.70315826 694.50 4.26097799e+00 -4.58280370e+00 6.25763719e+00 -0.82177217 0.70290229 694.75 4.83271015e+00 -4.80420264e+00 6.81435620e+00 -0.78244001 0.71769003 695.00 4.02530825e+00 -4.80486764e+00 6.26816238e+00 -0.87345343 0.64140819 695.25 3.22197426e+00 -3.73297355e+00 4.93114689e+00 -0.85873915 0.57900935 695.50 2.71774146e+00 -4.40270771e+00 5.17396887e+00 -1.01776149 0.65914772 695.75 2.55779006e+00 -5.34275586e+00 5.92345593e+00 -1.12430105 0.69899516 696.00 2.42553030e+00 -4.71845470e+00 5.30537576e+00 -1.09597055 0.52368649 696.25 1.81825500e+00 -3.31470588e+00 3.78065157e+00 -1.06907328 0.33143234 696.50 1.82992051e+00 -3.01733120e+00 3.52886620e+00 -1.02563313 0.35968757 696.75 2.35925858e+00 -3.08613555e+00 3.88462787e+00 -0.91809845 0.37124290 697.00 2.70789461e+00 -3.33150422e+00 4.29320551e+00 -0.88829042 0.38660375 697.25 3.74684125e+00 -2.81164387e+00 4.68445948e+00 -0.64375948 0.43891310 697.50 3.14764568e+00 -1.89581214e+00 3.67447643e+00 -0.54210550 0.38385814 697.75 2.00722895e+00 -9.97131434e-01 2.24125838e+00 -0.46106040 0.18541886 698.00 1.37852635e+00 -7.55180588e-02 1.38059331e+00 -0.05472703 0.06042329 698.25 1.02860515e+00 1.17149429e+00 1.55898282e+00 0.85025375 0.06869746 698.50 2.40280030e-01 1.52202869e+00 1.54087827e+00 1.41422028 0.06373296 698.75 4.49399413e-01 1.06695438e+00 1.15773549e+00 1.17215012 0.02068103 699.00 -1.58508336e-01 3.22598912e+00 3.22988091e+00 1.61989164 0.07885729 699.25 -2.88592465e-01 3.67812613e+00 3.68943050e+00 1.64909773 0.06374346 699.50 -2.53302934e+00 3.07358420e+00 3.98285795e+00 2.26007779 0.07796126 699.75 -5.45677252e+00 2.73925030e+00 6.10572342e+00 2.67635357 0.14448193 700.00 -5.71894194e+00 -5.78752464e-01 5.74815199e+00 -3.04073680 0.15503845 700.25 -4.94760502e+00 -2.92052411e+00 5.74528124e+00 -2.60834310 0.13974528 700.50 -6.00958327e+00 -3.15960345e+00 6.78956443e+00 -2.65754941 0.23157713 700.75 -6.23053293e+00 -4.84762674e+00 7.89424002e+00 -2.48038383 0.28263005 701.00 -5.64286473e+00 -7.45432380e+00 9.34927086e+00 -2.21875742 0.27112160 701.25 -5.22371456e+00 -8.38609005e+00 9.87996458e+00 -2.12788574 0.27204967 701.50 -1.72808093e+00 -8.56184719e+00 8.73450004e+00 -1.76995574 0.26154198 701.75 -1.65739709e-01 -7.97557544e+00 7.97729736e+00 -1.59157425 0.20571889 702.00 -7.07797837e-02 -8.50958116e+00 8.50987552e+00 -1.57911379 0.20731681 702.25 8.20187471e-01 -7.30927046e+00 7.35514392e+00 -1.45905183 0.18893238 702.50 3.42592830e-01 -5.82010775e+00 5.83018217e+00 -1.51200051 0.15357350 702.75 1.25430916e+00 -3.58018345e+00 3.79354781e+00 -1.23381176 0.07840823 703.00 2.91368369e+00 8.79778000e-02 2.91501162e+00 0.03018553 0.04879018 703.25 2.46717476e+00 1.11939732e+00 2.70924374e+00 0.42594007 0.04907639 703.50 3.63452353e+00 1.28517316e+00 3.85505271e+00 0.33987972 0.12922487 703.75 3.97487617e+00 1.45310520e+00 4.23215729e+00 0.35047991 0.15270198 704.00 1.75899525e+00 -4.37899996e-01 1.81268328e+00 -0.24398918 0.04377807 704.25 9.07470147e-01 -1.41541226e+00 1.68133695e+00 -1.00067845 0.04939478 704.50 5.95287891e-01 -3.44234634e+00 3.49343899e+00 -1.39955902 0.23750890 704.75 -2.53357114e-01 -2.87449954e+00 2.88564333e+00 -1.65870870 0.20756144 705.00 -4.73487533e-01 -2.20876848e+00 2.25894857e+00 -1.78196757 0.22620634 705.25 -2.42621033e-01 -2.36631887e+00 2.37872444e+00 -1.67297028 0.35680727 705.50 -4.30073207e-01 -2.18434465e+00 2.22628042e+00 -1.76519866 0.40000898 705.75 -9.87849729e-01 -2.10924413e+00 2.32911096e+00 -2.00879916 0.42276602 706.00 -1.49009837e+00 -2.20499549e+00 2.66127756e+00 -2.16508368 0.61296682 706.25 -1.45525537e+00 -2.10107003e+00 2.55582931e+00 -2.17655602 0.60521653 706.50 -1.38962670e+00 -1.89184909e+00 2.34737201e+00 -2.20432523 0.63715817 706.75 -1.12022084e+00 -1.74603333e+00 2.07449443e+00 -2.14122991 0.56023016 707.00 -8.89988899e-01 -1.80434611e+00 2.01190088e+00 -2.02902722 0.67942832 707.25 -5.11822574e-01 -1.89959469e+00 1.96733890e+00 -1.83398407 0.69459906 707.50 -3.71134864e-01 -1.91222416e+00 1.94790717e+00 -1.76249839 0.74608439 707.75 -2.34099415e-01 -1.85570580e+00 1.87041347e+00 -1.69628460 0.70010919 708.00 -7.46300793e-02 -1.87571367e+00 1.87719776e+00 -1.61056292 0.75992195 708.25 1.38544829e-01 -2.07363385e+00 2.07825696e+00 -1.50408290 0.78907624 708.50 4.44913426e-01 -2.15940187e+00 2.20475948e+00 -1.36760420 0.76420497 708.75 7.99878988e-01 -2.39659788e+00 2.52655651e+00 -1.24866540 0.77432292 709.00 9.58716336e-01 -2.63627416e+00 2.80518778e+00 -1.22200147 0.82472490 709.25 1.31742422e+00 -3.00138912e+00 3.27779548e+00 -1.15717941 0.84306303 709.50 1.72444205e+00 -3.25616383e+00 3.68460354e+00 -1.08375543 0.87288998 709.75 1.90983618e+00 -3.84281462e+00 4.29123507e+00 -1.10956050 0.86288638 710.00 1.87583347e+00 -4.25190097e+00 4.64730170e+00 -1.15530525 0.91001714 710.25 1.64381698e+00 -4.59410080e+00 4.87933361e+00 -1.22718050 0.90965824 710.50 1.65804948e+00 -4.83764355e+00 5.11389511e+00 -1.24060462 0.92240926 710.75 1.28434612e+00 -4.99523154e+00 5.15770134e+00 -1.31913302 0.93575416 711.00 1.22905982e+00 -5.17714758e+00 5.32103797e+00 -1.33771028 0.95308483 711.25 8.65329051e-01 -5.45299743e+00 5.52122951e+00 -1.41341990 0.95004471 711.50 5.66733536e-01 -5.59464069e+00 5.62327230e+00 -1.46984134 0.95952572 711.75 4.08683454e-01 -5.45692960e+00 5.47221187e+00 -1.49604331 0.97469591 712.00 2.89815806e-01 -5.30949837e+00 5.31740219e+00 -1.51626604 0.96995937 712.25 -1.48700230e-01 -4.92804293e+00 4.93028588e+00 -1.60096147 0.96298195 712.50 -3.59268743e-01 -4.73867063e+00 4.75227034e+00 -1.64646792 0.96290713 712.75 -5.02722644e-01 -4.23084384e+00 4.26060673e+00 -1.68906505 0.96768620 713.00 -5.30824432e-01 -3.94272073e+00 3.97829377e+00 -1.70462563 0.97133162 713.25 -5.24160233e-01 -3.42093964e+00 3.46086290e+00 -1.72283502 0.96343355 713.50 -4.83383881e-01 -3.23675718e+00 3.27265290e+00 -1.71904272 0.96087996 713.75 -3.94857117e-01 -2.90139837e+00 2.92814355e+00 -1.70605736 0.96795114 714.00 -3.60113469e-01 -2.72634681e+00 2.75002703e+00 -1.70212255 0.96307351 714.25 -9.84781992e-02 -2.36960239e+00 2.37164783e+00 -1.61233138 0.97110434 714.50 -2.70577461e-02 -2.23765250e+00 2.23781608e+00 -1.58288776 0.97189878 714.75 1.31060261e-01 -2.00655838e+00 2.01083399e+00 -1.50557303 0.98169316 715.00 2.04452158e-01 -1.95993184e+00 1.97056680e+00 -1.46685630 0.98099722 715.25 4.03508564e-01 -1.75434538e+00 1.80015190e+00 -1.34472300 0.98332073 715.50 4.67113311e-01 -1.69469361e+00 1.75789114e+00 -1.30184181 0.98181028 715.75 5.73413050e-01 -1.60501428e+00 1.70436891e+00 -1.22766538 0.98724952 716.00 6.12423785e-01 -1.55089284e+00 1.66743261e+00 -1.19470749 0.98899206 716.25 6.81636083e-01 -1.43881234e+00 1.59210826e+00 -1.12836909 0.98700154 716.50 7.31353899e-01 -1.34403347e+00 1.53013218e+00 -1.07245667 0.98062852 716.75 8.08290598e-01 -1.22766335e+00 1.46986088e+00 -0.98854033 0.98636780 717.00 8.93911877e-01 -1.18255682e+00 1.48240314e+00 -0.92352066 0.98752656 717.25 9.50070292e-01 -1.12757481e+00 1.47446889e+00 -0.87062663 0.99057738 717.50 1.00121614e+00 -1.08302158e+00 1.47491339e+00 -0.82462760 0.98534621 717.75 1.06962043e+00 -1.05311077e+00 1.50104302e+00 -0.77762076 0.97778777 718.00 1.10996063e+00 -9.98262075e-01 1.49282945e+00 -0.73246533 0.96846541 718.25 1.12667775e+00 -9.23393809e-01 1.45672882e+00 -0.68656182 0.97549711 718.50 1.14482958e+00 -9.05366964e-01 1.45956298e+00 -0.66912516 0.96260124 718.75 1.12133550e+00 -8.74216450e-01 1.42184659e+00 -0.66219047 0.95374172 719.00 1.15535713e+00 -7.50233778e-01 1.37757062e+00 -0.57591974 0.94163110 719.25 1.09618769e+00 -6.28890958e-01 1.26377660e+00 -0.52086229 0.93216431 719.50 1.12149893e+00 -5.40041153e-01 1.24475070e+00 -0.44876691 0.91612385 719.75 1.19856021e+00 -3.61321495e-01 1.25183857e+00 -0.29279841 0.91145979 720.00 1.32237455e+00 -2.55875072e-01 1.34690256e+00 -0.19113461 0.88881661 720.25 1.54593843e+00 -1.06887847e-01 1.54962920e+00 -0.06903122 0.91918418 720.50 1.91100722e+00 -1.11627035e-01 1.91426466e+00 -0.05834637 0.94446777 720.75 2.11141242e+00 -2.43926061e-01 2.12545579e+00 -0.11501755 0.95526977 721.00 2.12939158e+00 -6.24626128e-01 2.21911386e+00 -0.28533141 0.93967271 721.25 2.10384460e+00 -9.35594078e-01 2.30249829e+00 -0.41844342 0.95883498 721.50 2.02289752e+00 -1.12172206e+00 2.31308771e+00 -0.50630114 0.95888031 721.75 1.89123333e+00 -1.20056703e+00 2.24011712e+00 -0.56562006 0.95872385 722.00 1.61864881e+00 -1.16548463e+00 1.99458727e+00 -0.62404644 0.95322612 722.25 1.51349312e+00 -1.10852581e+00 1.87603063e+00 -0.63216031 0.94686457 722.50 1.45041739e+00 -1.02596622e+00 1.77660274e+00 -0.61564803 0.93540742 722.75 1.44638254e+00 -1.00706665e+00 1.76244310e+00 -0.60821537 0.93851488 723.00 1.33496176e+00 -8.48784269e-01 1.58194742e+00 -0.56633625 0.91254291 723.25 1.31037031e+00 -8.33709118e-01 1.55310696e+00 -0.56664073 0.89093825 723.50 1.34607379e+00 -8.49797589e-01 1.59187644e+00 -0.56312809 0.89184826 723.75 1.27184673e+00 -7.40332001e-01 1.47162684e+00 -0.52714789 0.86776980 724.00 1.28253206e+00 -5.34545365e-01 1.38947013e+00 -0.39489542 0.87141800 724.25 1.34753424e+00 -4.37541777e-01 1.41678909e+00 -0.31395880 0.85318081 724.50 1.68048154e+00 -1.88088322e-01 1.69097470e+00 -0.11146136 0.82024955 724.75 1.90488743e+00 -1.33398403e-01 1.90955264e+00 -0.06991540 0.80985124 725.00 2.57255713e+00 -2.42877806e-01 2.58399687e+00 -0.09413203 0.76535880 725.25 3.27008230e+00 -4.15336199e-01 3.29635290e+00 -0.12633450 0.78098261 725.50 3.80001773e+00 -1.66021969e+00 4.14686197e+00 -0.41190494 0.80319624 725.75 3.61451129e+00 -2.35651964e+00 4.31484376e+00 -0.57775240 0.73459386 726.00 3.03747167e+00 -4.13916870e+00 5.13409696e+00 -0.93772059 0.74200168 726.25 1.84475602e+00 -4.65224328e+00 5.00464707e+00 -1.19328453 0.75521214 726.50 6.27270417e-01 -4.70687982e+00 4.74849301e+00 -1.43831025 0.78568072 726.75 -2.64054519e-01 -4.58067724e+00 4.58828168e+00 -1.62837790 0.83014802 727.00 -1.38566924e+00 -4.67795556e+00 4.87886743e+00 -1.85877480 0.90029281 727.25 -1.67509737e+00 -4.08726694e+00 4.41720526e+00 -1.95975069 0.86780817 727.50 -2.15369019e+00 -3.46870929e+00 4.08293100e+00 -2.12643536 0.88950762 727.75 -2.48861681e+00 -2.65015696e+00 3.63545672e+00 -2.32476930 0.87317709 728.00 -2.49867957e+00 -1.69684438e+00 3.02037753e+00 -2.54503412 0.89611382 728.25 -2.27216947e+00 -1.33944247e+00 2.63758606e+00 -2.60892999 0.89391096 728.50 -2.24212116e+00 -1.13062158e+00 2.51105803e+00 -2.67453945 0.92566586 728.75 -2.17920415e+00 -1.06570280e+00 2.42583041e+00 -2.68675705 0.91119386 729.00 -2.23924393e+00 -7.89850746e-01 2.37446364e+00 -2.80248695 0.92374586 729.25 -2.31080207e+00 -4.19176802e-01 2.34851344e+00 -2.96214511 0.88134540 729.50 -2.23118229e+00 1.02401706e-01 2.23353095e+00 3.09572912 0.86909657 729.75 -1.66760305e+00 6.44777394e-01 1.78791437e+00 2.77264830 0.80519406 730.00 -1.19423074e+00 8.57412886e-01 1.47015098e+00 2.51891277 0.81902687 730.25 -6.91432350e-01 7.58454939e-01 1.02631992e+00 2.31000131 0.69541837 730.50 -4.76069283e-01 6.48031330e-01 8.04106067e-01 2.20439389 0.67791832 730.75 -1.88785259e-01 3.06808238e-01 3.60237657e-01 2.12240447 0.29372536 731.00 1.40613979e-02 1.12460483e-01 1.13336151e-01 1.44640773 0.06244592 731.25 -6.08962057e-02 -4.62254065e-03 6.10713988e-02 -3.06582943 0.01621775 731.50 -6.80376292e-02 -5.72396617e-02 8.89128667e-02 -2.44217453 0.04214359 731.75 -2.93911319e-02 -1.98749549e-01 2.00910980e-01 -1.71761252 0.18583096 732.00 -2.70798871e-02 -3.08196858e-01 3.09384265e-01 -1.65843680 0.34974612 732.25 -7.19351640e-02 -3.43503161e-01 3.50954541e-01 -1.77722942 0.35934468 732.50 -9.82967766e-02 -3.78630771e-01 3.91182204e-01 -1.82480014 0.41620021 732.75 -2.94444627e-02 -5.51056227e-01 5.51842316e-01 -1.62417834 0.62834483 733.00 4.05529064e-03 -5.99107320e-01 5.99121045e-01 -1.56402754 0.70776322 733.25 -7.54352397e-02 -7.11977739e-01 7.15962832e-01 -1.67635420 0.73573209 733.50 -8.32052937e-02 -7.65242465e-01 7.69752656e-01 -1.67910148 0.76309505 733.75 -2.28234756e-01 -8.05393842e-01 8.37108323e-01 -1.84693913 0.69726852 734.00 -3.52132746e-01 -8.24748725e-01 8.96776410e-01 -1.97432392 0.72556187 734.25 -5.81046402e-01 -6.39346982e-01 8.63932570e-01 -2.30845882 0.72248185 734.50 -4.65996833e-01 -4.89223995e-01 6.75642780e-01 -2.33188327 0.53121491 734.75 1.19449856e-01 -4.43804506e-01 4.59598420e-01 -1.30787717 0.27041598 735.00 2.82163870e-01 -6.30853601e-01 6.91080831e-01 -1.15021237 0.41842780 735.25 6.25044401e-01 -1.00465336e+00 1.18321970e+00 -1.01424957 0.53792010 735.50 9.01046079e-01 -1.44846002e+00 1.70584890e+00 -1.01430548 0.61553507 735.75 6.52545735e-01 -2.26319064e+00 2.35538698e+00 -1.29008005 0.75548221 736.00 3.31640833e-01 -2.60673769e+00 2.62774943e+00 -1.44425168 0.77610079 736.25 -1.82630652e-01 -2.99193079e+00 2.99749959e+00 -1.63176175 0.72339899 736.50 -5.63532292e-01 -3.26924273e+00 3.31745636e+00 -1.74149285 0.76905347 736.75 -1.17757484e+00 -3.58051224e+00 3.76918431e+00 -1.88853757 0.85049707 737.00 -1.69069557e+00 -3.58237978e+00 3.96129984e+00 -2.01175124 0.83517588 737.25 -2.39367004e+00 -3.65093166e+00 4.36565668e+00 -2.15112105 0.75409901 737.50 -2.85656216e+00 -3.65658827e+00 4.64010615e+00 -2.23397428 0.74084780 737.75 -3.78554027e+00 -3.80049399e+00 5.36414669e+00 -2.35422328 0.80955170 738.00 -4.27338679e+00 -3.27959083e+00 5.38679410e+00 -2.48701969 0.74849307 738.25 -5.48259427e+00 -2.15594613e+00 5.89125994e+00 -2.76693203 0.82156283 738.50 -5.63649413e+00 -1.36562026e+00 5.79956764e+00 -2.90389121 0.82928912 738.75 -5.29233280e+00 -3.07916153e-01 5.30128275e+00 -3.08347662 0.81053751 739.00 -5.29704067e+00 3.40226206e-01 5.30795570e+00 3.07745127 0.81836111 739.25 -4.85101584e+00 7.89757821e-01 4.91488271e+00 2.98020598 0.85254981 739.50 -4.85990017e+00 1.21413737e+00 5.00926734e+00 2.89677622 0.82365009 739.75 -5.46913829e+00 1.41116989e+00 5.64826292e+00 2.88907620 0.88536121 740.00 -5.16035342e+00 1.68225961e+00 5.42763713e+00 2.82645929 0.87899253 740.25 -4.57223373e+00 1.96900041e+00 4.97818078e+00 2.73495207 0.86175270 740.50 -4.25730547e+00 2.43325121e+00 4.90360697e+00 2.62235708 0.81016600 740.75 -4.10675340e+00 3.28430130e+00 5.25852247e+00 2.46701527 0.81490363 741.00 -3.33174822e+00 3.81925382e+00 5.06825867e+00 2.28812676 0.82983888 741.25 -2.86387447e+00 4.28521331e+00 5.15410808e+00 2.15993956 0.84889381 741.50 -1.72620900e+00 4.52214068e+00 4.84040844e+00 1.93544882 0.80620170 741.75 -1.10506215e+00 4.28860173e+00 4.42868684e+00 1.82298465 0.85757447 742.00 -3.10589690e-01 3.79311119e+00 3.80580589e+00 1.65249663 0.77835385 742.25 1.49256572e-01 3.43146557e+00 3.43471010e+00 1.52732728 0.71559505 742.50 9.68189287e-01 2.33679396e+00 2.52942612e+00 1.17800318 0.62049237 742.75 1.25590316e+00 1.51597620e+00 1.96862302e+00 0.87894981 0.47933373 743.00 1.12094481e+00 2.90921649e-01 1.15808146e+00 0.25393014 0.16804100 743.25 6.73568610e-01 -6.98213750e-01 9.70153139e-01 -0.80336201 0.12067457 743.50 -8.14485773e-01 -9.86367490e-01 1.27918251e+00 -2.26103814 0.24406917 743.75 -1.35208993e+00 -1.08718917e+00 1.73497189e+00 -2.46436854 0.30228174 744.00 -2.56813763e+00 -1.23870941e-01 2.57112328e+00 -3.09339624 0.34988110 744.25 -2.52599100e+00 9.91535706e-01 2.71362739e+00 2.76753957 0.36304057 744.50 -3.74136721e+00 2.48821146e+00 4.49321988e+00 2.55470730 0.69428415 744.75 -3.67259761e+00 2.73319982e+00 4.57802954e+00 2.50180466 0.71237761 745.00 -2.91100230e+00 3.85690197e+00 4.83214520e+00 2.21733143 0.75295375 745.25 -2.56958918e+00 4.04594387e+00 4.79295841e+00 2.13662742 0.73927708 745.50 -1.68281987e+00 4.12935644e+00 4.45908817e+00 1.95777370 0.68050022 745.75 -1.14374796e+00 4.05839870e+00 4.21648662e+00 1.84549421 0.73030784 746.00 -1.27775977e-01 3.84173342e+00 3.84385775e+00 1.60404405 0.75374350 746.25 9.56435391e-02 3.37559158e+00 3.37694628e+00 1.54247005 0.68540843 746.50 -1.60581513e-01 2.46487533e+00 2.47010057e+00 1.63585232 0.58966037 746.75 8.22196448e-02 1.93289846e+00 1.93464635e+00 1.52828498 0.51707025 747.00 -1.64830290e-01 1.57960915e+00 1.58818578e+00 1.67476882 0.49538076 747.25 -7.11555523e-01 1.50300460e+00 1.66292937e+00 2.01295641 0.56847438 747.50 -1.01508154e+00 1.57268124e+00 1.87182179e+00 2.14396380 0.69623818 747.75 -1.13632013e+00 1.51120188e+00 1.89075502e+00 2.21553238 0.60056416 748.00 -1.25472697e+00 1.50162500e+00 1.95683863e+00 2.26685871 0.53001831 748.25 -1.21046185e+00 1.73949405e+00 2.11921151e+00 2.17874515 0.56582375 748.50 -7.20376539e-01 1.87869059e+00 2.01206876e+00 1.93695114 0.55118715 748.75 -2.55215000e-01 1.46416849e+00 1.48624495e+00 1.74336963 0.33402994 749.00 9.70978265e-02 1.03693189e+00 1.04146806e+00 1.47742904 0.21097100 749.25 -8.30976131e-02 8.97192935e-01 9.01032950e-01 1.66315240 0.18378610 749.50 -1.77923228e-01 8.72289479e-01 8.90250307e-01 1.77200884 0.16309071 749.75 -5.96855450e-01 2.92134216e-01 6.64513979e-01 2.68641613 0.07555904 750.00 -9.14624130e-01 2.69654439e-02 9.15021549e-01 3.11211865 0.15370014 750.25 -1.53715496e+00 -5.66781058e-01 1.63831808e+00 -2.78833834 0.34486419 750.50 -2.09242764e+00 -1.30229119e+00 2.46459241e+00 -2.58487751 0.56684791 750.75 -2.65267040e+00 -1.51404924e+00 3.05434205e+00 -2.62294753 0.54362575 751.00 -4.05273474e+00 -1.72811854e+00 4.40579761e+00 -2.73853002 0.65746323 751.25 -5.58716890e+00 -4.38628598e-01 5.60436003e+00 -3.06324693 0.72658962 751.50 -6.45935886e+00 2.03467932e-01 6.46256266e+00 3.11010336 0.75150051 751.75 -6.50695796e+00 2.16683056e+00 6.85825463e+00 2.82014025 0.77999429 752.00 -6.67663864e+00 2.55913664e+00 7.15029258e+00 2.77556768 0.82843868 752.25 -5.90144305e+00 3.35381798e+00 6.78786602e+00 2.62480461 0.77556230 752.50 -5.13861821e+00 3.80750090e+00 6.39550313e+00 2.50390351 0.79135312 752.75 -5.45617484e+00 3.90111653e+00 6.70735075e+00 2.52087623 0.80568811 753.00 -5.09134715e+00 4.17413665e+00 6.58370963e+00 2.45486521 0.78661511 753.25 -3.18198046e+00 4.10023489e+00 5.19007956e+00 2.23076102 0.68367303 753.50 -3.35971693e+00 4.18197501e+00 5.36438373e+00 2.24759512 0.64367856 753.75 -3.65402772e+00 2.85607846e+00 4.63779072e+00 2.47815700 0.56009232 754.00 -3.61807399e+00 2.55856230e+00 4.43133168e+00 2.52607653 0.62203903 754.25 -3.59684004e+00 2.89565988e+00 4.61758643e+00 2.46377600 0.59924636 754.50 -3.99710441e+00 3.01047001e+00 5.00397575e+00 2.49607048 0.60242916 754.75 -4.10060936e+00 1.18008030e+00 4.26703488e+00 2.86138266 0.46682226 755.00 -3.86743751e+00 1.02672777e+00 4.00140510e+00 2.88209836 0.38148402 755.25 -4.68481420e+00 6.42303451e-01 4.72864017e+00 3.00533886 0.37012386 755.50 -5.72101750e+00 -4.38867565e-02 5.72118583e+00 -3.13392166 0.38971925 755.75 -5.44333529e+00 2.99983732e-01 5.45159512e+00 3.08653806 0.21900720 756.00 -6.67613003e+00 -1.94848827e-01 6.67897285e+00 -3.11241504 0.27207912 756.25 -7.69032982e+00 3.65551163e+00 8.51492443e+00 2.69786798 0.44895552 756.50 -7.19793267e+00 3.44922478e+00 7.98169069e+00 2.69472585 0.44003526 756.75 -7.17802205e+00 2.85687856e+00 7.72565568e+00 2.76280850 0.36338860 757.00 -6.83880835e+00 2.59151321e+00 7.31336040e+00 2.77937028 0.43224422 757.25 -7.31570951e+00 2.44792358e+00 7.71439793e+00 2.81869182 0.53730011 757.50 -7.92933132e+00 1.02141555e+00 7.99484740e+00 3.01348329 0.53908109 757.75 -8.07370200e+00 -1.07631519e+00 8.14512850e+00 -3.00906283 0.59486022 758.00 -7.58213110e+00 -2.31388233e+00 7.92734278e+00 -2.84539428 0.62270091 758.25 -6.39227094e+00 -4.08955252e+00 7.58851550e+00 -2.57244605 0.76433671 758.50 -5.55613514e+00 -4.84969970e+00 7.37497287e+00 -2.42397888 0.79121370 758.75 -4.65965407e+00 -6.06813254e+00 7.65079137e+00 -2.22564863 0.74643507 759.00 -3.94164089e+00 -6.05285395e+00 7.22312771e+00 -2.14801727 0.73892221 759.25 -3.55449312e+00 -5.71152101e+00 6.72725008e+00 -2.12747867 0.71924516 759.50 -3.34670732e+00 -5.55324216e+00 6.48374494e+00 -2.11316815 0.75132181 759.75 -3.13224918e+00 -5.89831308e+00 6.67840416e+00 -2.05896768 0.76238044 760.00 -2.46006127e+00 -5.30799781e+00 5.85036257e+00 -2.00478962 0.74064533 760.25 -2.23838834e+00 -4.79468812e+00 5.29144749e+00 -2.00757200 0.82739903 760.50 -2.08750264e+00 -4.48374608e+00 4.94587163e+00 -2.00652347 0.87949384 760.75 -1.43074910e+00 -4.13035072e+00 4.37113716e+00 -1.90425948 0.89796829 761.00 -9.87166682e-01 -3.88062257e+00 4.00421398e+00 -1.81989644 0.90422183 761.25 -9.38238455e-01 -3.48820674e+00 3.61218461e+00 -1.83355204 0.89480469 761.50 -9.26286372e-01 -3.05006745e+00 3.18761947e+00 -1.86563841 0.87464443 761.75 -9.02238683e-01 -2.78566969e+00 2.92813768e+00 -1.88402008 0.89297643 762.00 -6.44368915e-01 -2.37741582e+00 2.46319250e+00 -1.83547494 0.83291712 762.25 -3.89847976e-01 -1.94956350e+00 1.98815977e+00 -1.76815996 0.81321070 762.50 -9.42032044e-02 -1.76058361e+00 1.76310206e+00 -1.62425216 0.80663802 762.75 2.43476230e-01 -1.68353793e+00 1.70105280e+00 -1.42717037 0.83229451 763.00 6.05463180e-01 -1.57314056e+00 1.68563249e+00 -1.20339596 0.86943667 763.25 8.34225400e-01 -1.62876125e+00 1.82997137e+00 -1.09744912 0.89497010 763.50 1.09357665e+00 -1.77062777e+00 2.08111331e+00 -1.01752096 0.92092904 763.75 1.13706275e+00 -1.70489458e+00 2.04928700e+00 -0.98260437 0.92452006 764.00 1.25443507e+00 -1.75186562e+00 2.15467875e+00 -0.94937516 0.93473999 764.25 1.30556849e+00 -1.71728975e+00 2.15721885e+00 -0.92076781 0.94228738 764.50 1.33934781e+00 -1.64452241e+00 2.12092115e+00 -0.88731854 0.95846551 764.75 1.37330603e+00 -1.65451790e+00 2.15020904e+00 -0.87800839 0.95924963 765.00 1.50019242e+00 -1.71471952e+00 2.27834157e+00 -0.85202815 0.94625163 765.25 1.54226000e+00 -1.74922968e+00 2.33203138e+00 -0.84819573 0.95141084 765.50 1.47574555e+00 -1.86853270e+00 2.38101646e+00 -0.90231303 0.93240768 765.75 1.32072739e+00 -1.83253414e+00 2.25887189e+00 -0.94630522 0.91576901 766.00 1.13735219e+00 -1.66242491e+00 2.01425584e+00 -0.97078562 0.91516811 766.25 1.20096365e+00 -1.67442566e+00 2.06058608e+00 -0.94859391 0.91386869 766.50 1.28572529e+00 -1.52131521e+00 1.99185579e+00 -0.86913015 0.90032037 766.75 1.34395185e+00 -1.45803059e+00 1.98294220e+00 -0.82608927 0.91830158 767.00 1.42226393e+00 -1.48466727e+00 2.05598433e+00 -0.80686195 0.92966613 767.25 1.51851507e+00 -1.42932531e+00 2.08539177e+00 -0.75515142 0.90750726 767.50 1.57227731e+00 -1.49569533e+00 2.17006001e+00 -0.76044159 0.90612526 767.75 1.56276431e+00 -1.60534503e+00 2.24039393e+00 -0.79883778 0.90819172 768.00 1.59957998e+00 -1.98829508e+00 2.55185686e+00 -0.89331854 0.92866066 768.25 1.44973168e+00 -2.02191560e+00 2.48794386e+00 -0.94874590 0.92837564 768.50 1.34361377e+00 -2.14734388e+00 2.53305818e+00 -1.01168687 0.94476643 768.75 1.20161640e+00 -2.20242699e+00 2.50889749e+00 -1.07134723 0.94111025 769.00 9.52260237e-01 -2.15263977e+00 2.35386014e+00 -1.15430677 0.93639131 769.25 7.86349165e-01 -1.88487077e+00 2.04232290e+00 -1.17555941 0.90646286 769.50 6.08152412e-01 -1.54436886e+00 1.65979653e+00 -1.19565741 0.85844237 769.75 6.52994296e-01 -1.33579269e+00 1.48685698e+00 -1.11611325 0.76201481 770.00 6.29924711e-01 -1.31353700e+00 1.45677197e+00 -1.12363098 0.54608728 770.25 7.69154260e-01 -1.19760073e+00 1.42332209e+00 -0.99989141 0.43380756 770.50 1.35058120e+00 -8.52053140e-01 1.59689202e+00 -0.56281565 0.41635379 770.75 1.54769105e+00 -1.38367959e+00 2.07603391e+00 -0.72950600 0.36763372 771.00 1.55901396e+00 -2.01251809e+00 2.54573243e+00 -0.91169974 0.40874036 771.25 1.13760751e+00 -2.61791909e+00 2.85440908e+00 -1.16086760 0.46062781 771.50 5.54764611e-01 -3.45863801e+00 3.50284751e+00 -1.41175133 0.58080230 771.75 -8.05485910e-02 -3.32541069e+00 3.32638608e+00 -1.59501374 0.64861362 772.00 -3.56802705e-01 -3.45089332e+00 3.46928996e+00 -1.67382453 0.61587303 772.25 -7.91299826e-01 -3.47285086e+00 3.56186026e+00 -1.79482472 0.77068770 772.50 -9.01029785e-01 -3.35135195e+00 3.47036231e+00 -1.83344123 0.81216586 772.75 -1.14354747e+00 -2.86186936e+00 3.08188206e+00 -1.95094110 0.79518753 773.00 -1.56051182e+00 -2.62684911e+00 3.05541051e+00 -2.10683837 0.83985995 773.25 -1.58762052e+00 -2.07248284e+00 2.61069417e+00 -2.22448904 0.77914917 773.50 -1.55579579e+00 -1.72378289e+00 2.32205254e+00 -2.30501706 0.76939504 773.75 -1.31346360e+00 -1.42391297e+00 1.93719250e+00 -2.31586774 0.74288597 774.00 -1.08425777e+00 -1.31856854e+00 1.70711391e+00 -2.25898718 0.65452946 774.25 -5.86949857e-01 -1.18913851e+00 1.32610728e+00 -2.02930482 0.48672420 774.50 -3.73166543e-01 -1.11222446e+00 1.17315665e+00 -1.89450792 0.45364533 774.75 -3.82125926e-01 -1.38911481e+00 1.44071516e+00 -1.83924242 0.49226747 775.00 -3.87264485e-01 -1.61332852e+00 1.65915722e+00 -1.80637978 0.57124445 775.25 -3.59972443e-01 -1.95745356e+00 1.99027752e+00 -1.75266267 0.68654207 775.50 -4.16259312e-01 -2.15058398e+00 2.19049840e+00 -1.76198852 0.79094161 775.75 -4.93842723e-01 -2.13952248e+00 2.19577710e+00 -1.79764255 0.83414673 776.00 -5.63409612e-01 -2.00863255e+00 2.08615319e+00 -1.84426317 0.82088249 776.25 -8.00004246e-01 -1.97224324e+00 2.12832098e+00 -1.95614811 0.86091840 776.50 -9.33128598e-01 -2.07912081e+00 2.27891911e+00 -1.99265956 0.88931112 776.75 -1.34979793e+00 -2.03549003e+00 2.44237059e+00 -2.15634764 0.92262811 777.00 -1.55565813e+00 -1.90093850e+00 2.45634676e+00 -2.25663448 0.93268805 777.25 -1.72343690e+00 -1.69586314e+00 2.41788886e+00 -2.36425847 0.92565460 777.50 -1.73959439e+00 -1.32699091e+00 2.18794275e+00 -2.48993946 0.87525917 777.75 -1.75732928e+00 -8.81680937e-01 1.96610465e+00 -2.67657286 0.90866561 778.00 -1.63681486e+00 -8.10161777e-01 1.82634197e+00 -2.68198326 0.91189869 778.25 -1.39179379e+00 -5.78049742e-01 1.50706054e+00 -2.74794345 0.88218023 778.50 -1.26271736e+00 -5.37966770e-01 1.37253903e+00 -2.73884234 0.87579975 778.75 -1.17712189e+00 -6.28296803e-01 1.33430612e+00 -2.65130570 0.90467934 779.00 -1.20373595e+00 -7.15211171e-01 1.40018115e+00 -2.60547869 0.91759826 779.25 -1.18400721e+00 -7.23942064e-01 1.38779148e+00 -2.59280832 0.93422662 779.50 -1.28492442e+00 -6.41144427e-01 1.43600033e+00 -2.67876584 0.90572874 779.75 -1.41472592e+00 -3.57177797e-01 1.45911803e+00 -2.89428935 0.89226956 780.00 -1.38351555e+00 -1.18650969e-01 1.38859401e+00 -3.05604149 0.89518092 780.25 -1.10440974e+00 1.11949189e-01 1.11006914e+00 3.04057208 0.83843650 780.50 -9.38446733e-01 1.35186620e-01 9.48133794e-01 2.99852328 0.79399233 780.75 -6.61329427e-01 1.35539678e-01 6.75076007e-01 2.93944173 0.64961979 781.00 -5.04264792e-01 -1.43410784e-01 5.24261036e-01 -2.86451241 0.45408889 781.25 -5.01301695e-01 -4.93179552e-01 7.03227886e-01 -2.36436152 0.65736229 781.50 -6.76753189e-01 -6.00668730e-01 9.04874468e-01 -2.41568516 0.80425014 781.75 -9.12419437e-01 -6.69319189e-01 1.13159065e+00 -2.50869302 0.88469389 782.00 -1.11382101e+00 -6.42836743e-01 1.28601567e+00 -2.61814749 0.87619857 782.25 -1.27934172e+00 -4.40711825e-01 1.35312311e+00 -2.80984094 0.84690050 782.50 -1.37245128e+00 -1.79780810e-01 1.38417617e+00 -3.01134178 0.83590459 782.75 -1.43230355e+00 4.03114783e-02 1.43287071e+00 3.11345557 0.84277815 783.00 -1.28306916e+00 3.33684940e-01 1.32574964e+00 2.88716111 0.74809387 783.25 -1.13177535e+00 5.18577123e-01 1.24492476e+00 2.71194228 0.70510951 783.50 -6.87370701e-01 5.53417016e-01 8.82467492e-01 2.46373656 0.58655539 783.75 -5.69870849e-01 6.02456771e-01 8.29280981e-01 2.32840573 0.62613219 784.00 -3.98808016e-01 6.34408777e-01 7.49347937e-01 2.13200130 0.48480176 784.25 -1.76338799e-01 6.13455185e-01 6.38296668e-01 1.85070163 0.34308090 784.50 -2.64144819e-03 4.02844321e-01 4.02852981e-01 1.57735323 0.24293676 784.75 7.66225887e-02 3.05385855e-01 3.14851618e-01 1.32496685 0.24155115 785.00 1.47647910e-01 1.94946304e-01 2.44548496e-01 0.92259043 0.24633578 785.25 1.12356716e-01 1.55512382e-01 1.91854457e-01 0.94513290 0.16114854 785.50 8.36316783e-02 4.19238572e-02 9.35514159e-02 0.46468035 0.05401587 785.75 1.05542035e-01 -6.38385293e-03 1.05734927e-01 -0.06041275 0.07095954 786.00 3.10284457e-02 -1.28051678e-01 1.31757340e-01 -1.33306651 0.09083129 786.25 -4.15601176e-02 -1.88843220e-01 1.93362367e-01 -1.78742042 0.20175070 786.50 -1.22090472e-01 -2.20409213e-01 2.51964888e-01 -2.07664902 0.42554878 786.75 -1.78540200e-01 -2.28703162e-01 2.90140896e-01 -2.23363498 0.49893450 787.00 -2.57106001e-01 -2.31265385e-01 3.45813785e-01 -2.40905701 0.58899294 787.25 -3.00705758e-01 -2.52201243e-01 3.92465821e-01 -2.44369683 0.73546709 787.50 -3.32060883e-01 -1.91481406e-01 3.83313917e-01 -2.61852263 0.80022248 787.75 -3.39503278e-01 -1.43320908e-01 3.68515073e-01 -2.74213946 0.82687771 788.00 -3.82259532e-01 -1.12320228e-01 3.98419607e-01 -2.85580379 0.84107564 788.25 -3.91978160e-01 -7.47559009e-02 3.99043009e-01 -2.95314124 0.82538199 788.50 -3.82236138e-01 -3.23918267e-02 3.83606172e-01 -3.05705167 0.86876361 788.75 -3.91414775e-01 -1.70742002e-02 3.91787002e-01 -3.09799853 0.87863464 789.00 -3.57257270e-01 1.52893448e-02 3.57584286e-01 3.09882230 0.81412369 789.25 -3.28804309e-01 3.49086675e-02 3.30652217e-01 3.03582036 0.82439929 789.50 -2.94108855e-01 6.60084257e-02 3.01425166e-01 2.92081571 0.81216142 789.75 -2.43757238e-01 3.91378105e-02 2.46879240e-01 2.98239082 0.68528939 790.00 -1.59615435e-01 -2.32404285e-02 1.61298495e-01 -2.99700605 0.52297501 790.25 -1.29858895e-01 -1.13353855e-01 1.72372936e-01 -2.42395316 0.43017387 790.50 -2.18868501e-01 -2.78151855e-01 3.53937671e-01 -2.23747785 0.75085002 790.75 -2.98983326e-01 -3.54090109e-01 4.63433744e-01 -2.27201322 0.78777269 791.00 -4.57249007e-01 -4.22454363e-01 6.22530596e-01 -2.39572658 0.81995022 791.25 -6.59619869e-01 -3.50260864e-01 7.46847404e-01 -2.65345049 0.83881571 791.50 -8.39002922e-01 -3.09726354e-01 8.94346866e-01 -2.78795175 0.90767062 791.75 -9.42827117e-01 -2.41886979e-01 9.73361332e-01 -2.89045419 0.91676681 792.00 -1.06469853e+00 -8.05890668e-02 1.06774414e+00 -3.06604480 0.90329344 792.25 -1.13629670e+00 1.11124682e-01 1.14171752e+00 3.04410717 0.90222001 792.50 -1.19256367e+00 2.31485113e-01 1.21482240e+00 2.94986968 0.89615173 792.75 -1.34382168e+00 2.82061531e-01 1.37310430e+00 2.93470097 0.83950154 793.00 -1.51446614e+00 4.03519387e-01 1.56730201e+00 2.88119879 0.83411359 793.25 -1.39404146e+00 9.05602777e-01 1.66236818e+00 2.56548181 0.78407767 793.50 -1.30045059e+00 1.35967879e+00 1.88146170e+00 2.33393301 0.85192588 793.75 -1.18947196e+00 1.50899988e+00 1.92143805e+00 2.23833260 0.82170906 794.00 -9.97182201e-01 1.57374429e+00 1.86307365e+00 2.13558224 0.75768127 794.25 -4.15844736e-01 1.83066156e+00 1.87729821e+00 1.79416140 0.72855374 794.50 -6.33869994e-02 1.93589439e+00 1.93693185e+00 1.60352764 0.78799668 794.75 2.15185495e-01 1.67808804e+00 1.69182867e+00 1.44325980 0.74904185 795.00 2.44721419e-01 1.66312758e+00 1.68103597e+00 1.42469942 0.81903254 795.25 4.39923760e-01 1.58470423e+00 1.64463382e+00 1.30000875 0.83749201 795.50 5.00637101e-01 1.50715435e+00 1.58812837e+00 1.25008977 0.83226128 795.75 5.86103021e-01 1.39100775e+00 1.50944338e+00 1.17202016 0.76957645 796.00 6.07999275e-01 1.47298612e+00 1.59353419e+00 1.17933305 0.76450374 796.25 8.48271479e-01 1.51109543e+00 1.73290908e+00 1.05927180 0.81636289 796.50 9.83441468e-01 1.44087840e+00 1.74450213e+00 0.97189227 0.82498680 796.75 1.06279567e+00 1.23597231e+00 1.63008042e+00 0.86059067 0.82092577 797.00 1.18545355e+00 1.15361752e+00 1.65412620e+00 0.77178846 0.84186814 797.25 1.36317128e+00 8.91240564e-01 1.62866377e+00 0.57904151 0.82551880 797.50 1.36698484e+00 6.34016149e-01 1.50685900e+00 0.43427573 0.72970324 797.75 1.55253446e+00 2.92307286e-01 1.57981227e+00 0.18609892 0.75405390 798.00 1.51956606e+00 2.23645550e-01 1.53593566e+00 0.14612817 0.78763811 798.25 1.54363043e+00 1.01575506e-01 1.54696881e+00 0.06570827 0.79642562 798.50 1.43693527e+00 3.11523443e-02 1.43727292e+00 0.02167632 0.73830588 798.75 1.25085760e+00 -4.68328471e-01 1.33565575e+00 -0.35824972 0.67477708 799.00 1.18329149e+00 -6.78920534e-01 1.36422573e+00 -0.52089884 0.66676358 799.25 9.63512131e-01 -8.16494025e-01 1.26294027e+00 -0.70299106 0.71570228 799.50 7.80230476e-01 -9.23751967e-01 1.20916388e+00 -0.86942693 0.69462849 799.75 4.32116070e-01 -1.00798397e+00 1.09670232e+00 -1.16580151 0.65426238 800.00 1.62278641e-01 -9.97691219e-01 1.01080271e+00 -1.40955422 0.62830232 800.25 -6.61121703e-02 -9.54146566e-01 9.56434257e-01 -1.63997508 0.69728435 800.50 -1.24206023e-01 -9.24398671e-01 9.32705762e-01 -1.70436051 0.72146892 800.75 -2.89815677e-01 -8.46865222e-01 8.95083142e-01 -1.90052499 0.78375834 801.00 -4.83415936e-01 -7.84787039e-01 9.21727543e-01 -2.12288564 0.73140857 801.25 -7.27749550e-01 -6.47659670e-01 9.74208630e-01 -2.41435867 0.71279443 801.50 -7.92218581e-01 -5.32532085e-01 9.54568332e-01 -2.54976666 0.73011956 801.75 -8.75012704e-01 -3.51634334e-01 9.43023827e-01 -2.75948216 0.72439440 802.00 -9.77947911e-01 -1.65802335e-01 9.91903489e-01 -2.97364857 0.78558130 802.25 -9.99645088e-01 -9.22696937e-03 9.99687671e-01 -3.13236267 0.82124997 802.50 -9.65249853e-01 1.97328921e-01 9.85213673e-01 2.93993825 0.74097771 802.75 -1.05268085e+00 4.15955788e-01 1.13188171e+00 2.76528337 0.79388015 803.00 -8.88312075e-01 6.80461700e-01 1.11898457e+00 2.48791954 0.74548925 803.25 -7.70960849e-01 8.41298338e-01 1.14112380e+00 2.31259547 0.78559203 803.50 -5.67856339e-01 9.11684766e-01 1.07407166e+00 2.12785874 0.83719659 803.75 -4.59928379e-01 9.01453122e-01 1.01200388e+00 2.04257676 0.87360560 804.00 -3.31322992e-01 8.94141951e-01 9.53553749e-01 1.92565865 0.87371200 804.25 -2.22409726e-01 8.90028440e-01 9.17396703e-01 1.81567201 0.86515156 804.50 -4.46598181e-02 9.42923854e-01 9.43980876e-01 1.61812408 0.88658168 804.75 6.19329489e-02 9.21541003e-01 9.23619786e-01 1.50369138 0.91411951 805.00 1.66350927e-01 8.09404778e-01 8.26322410e-01 1.36809631 0.89298663 805.25 1.85443050e-01 7.58911902e-01 7.81240296e-01 1.33113870 0.88441455 805.50 2.98941034e-01 6.20044702e-01 6.88346696e-01 1.12154811 0.86704805 805.75 3.47238183e-01 5.27257107e-01 6.31327500e-01 0.98841681 0.87086277 806.00 3.02620374e-01 3.93960982e-01 4.96773939e-01 0.91578126 0.71863643 806.25 3.31729292e-01 3.11384606e-01 4.54977687e-01 0.75377406 0.67179953 806.50 2.68660319e-01 2.09903094e-01 3.40936469e-01 0.66323124 0.42964681 806.75 1.88634725e-01 1.34117082e-01 2.31452913e-01 0.61806265 0.20727620 807.00 1.70988146e-01 -7.21454503e-02 1.85585323e-01 -0.39926955 0.19412466 807.25 1.39254128e-01 -1.45218334e-01 2.01196612e-01 -0.80636094 0.21204232 807.50 4.66443838e-02 -3.89336766e-01 3.92120920e-01 -1.45155991 0.46328039 807.75 -4.99418672e-02 -5.02664369e-01 5.05139246e-01 -1.66982563 0.52703853 808.00 -3.14169976e-01 -6.67645483e-01 7.37870764e-01 -2.01061912 0.63282240 808.25 -5.85139614e-01 -7.73432565e-01 9.69838285e-01 -2.21847562 0.69823640 808.50 -1.18640532e+00 -8.66734894e-01 1.46928110e+00 -2.51065263 0.81122268 808.75 -1.52030041e+00 -8.12454961e-01 1.72377388e+00 -2.65080196 0.84984627 809.00 -1.97417320e+00 -5.19278141e-01 2.04132546e+00 -2.88438317 0.86974483 809.25 -2.16368989e+00 -2.01439816e-01 2.17304669e+00 -3.04876012 0.84331437 809.50 -2.47071096e+00 4.08317461e-01 2.50422359e+00 2.97780988 0.83325543 809.75 -2.38912827e+00 9.25257296e-01 2.56203727e+00 2.77210122 0.79008186 810.00 -2.18806901e+00 1.59101894e+00 2.70536268e+00 2.51288724 0.76377169 810.25 -1.69068783e+00 1.74257690e+00 2.42796202e+00 2.34108202 0.71995927 810.50 -1.21461299e+00 1.86877104e+00 2.22880908e+00 2.14713837 0.75903111 810.75 -1.01279777e+00 1.86048248e+00 2.11829044e+00 2.06930968 0.72460819 811.00 -9.07591463e-01 1.52174969e+00 1.77184773e+00 2.10857423 0.63292648 811.25 -8.39275898e-01 1.31324645e+00 1.55852503e+00 2.13946002 0.57880241 811.50 -1.11229905e+00 1.29451812e+00 1.70674730e+00 2.28062909 0.61402995 811.75 -1.06272412e+00 1.22076557e+00 1.61853363e+00 2.28709419 0.57481804 812.00 -1.12649565e+00 1.30122215e+00 1.72109602e+00 2.28434687 0.59388932 812.25 -1.28614595e+00 1.37729671e+00 1.88444093e+00 2.32198493 0.63004525 812.50 -1.55285313e+00 1.70369058e+00 2.30519293e+00 2.30990931 0.68767478 812.75 -1.94819134e+00 2.12590368e+00 2.88355960e+00 2.31260205 0.70404329 813.00 -2.09641960e+00 2.66811813e+00 3.39320343e+00 2.23677508 0.74963283 813.25 -2.01148009e+00 3.44607032e+00 3.99016953e+00 2.09914622 0.74025829 813.50 -1.93928582e+00 3.90492014e+00 4.35995766e+00 2.03174129 0.76485961 813.75 -1.35926256e+00 4.36603411e+00 4.57272879e+00 1.87261183 0.70955966 814.00 -5.74175995e-01 5.15675509e+00 5.18862227e+00 1.68168402 0.72840540 814.25 9.83654405e-01 5.81711378e+00 5.89969395e+00 1.40328428 0.74961630 814.50 1.81946883e+00 5.28991649e+00 5.59407573e+00 1.23952105 0.77398121 814.75 2.83145107e+00 4.88088391e+00 5.64270705e+00 1.04512999 0.78575409 815.00 3.53022505e+00 5.10540115e+00 6.20706129e+00 0.96581905 0.79831773 815.25 3.97729745e+00 4.47323278e+00 5.98570853e+00 0.84401782 0.77256282 815.50 4.37614857e+00 3.88617644e+00 5.85260998e+00 0.72616557 0.78007260 815.75 4.50482779e+00 2.87196612e+00 5.34243978e+00 0.56755947 0.75010753 816.00 4.95658803e+00 2.42539834e+00 5.51818104e+00 0.45507379 0.80385661 816.25 5.06721298e+00 1.35125063e+00 5.24428504e+00 0.26060126 0.82926246 816.50 4.94920196e+00 8.90603486e-01 5.02869512e+00 0.17804345 0.82082773 816.75 4.10021202e+00 3.45076429e-01 4.11470733e+00 0.08396277 0.77361687 817.00 3.67644770e+00 1.60401711e-01 3.67994517e+00 0.04360189 0.72722760 817.25 3.35993237e+00 1.94346247e-01 3.36554839e+00 0.05777793 0.73937457 817.50 3.57276139e+00 1.99690808e-01 3.57833766e+00 0.05583447 0.79516143 817.75 3.37750249e+00 9.78924282e-02 3.37892083e+00 0.02897556 0.75905278 818.00 3.43619917e+00 -2.48571280e-01 3.44517814e+00 -0.07221323 0.75982684 818.25 3.34152145e+00 -9.47257253e-01 3.47319189e+00 -0.27623354 0.80296273 818.50 3.13549729e+00 -1.25162484e+00 3.37607879e+00 -0.37979846 0.80476634 818.75 2.97027983e+00 -1.45554167e+00 3.30774301e+00 -0.45564404 0.80442300 819.00 3.03395168e+00 -1.46979818e+00 3.37122671e+00 -0.45113048 0.80153949 819.25 2.73123108e+00 -1.97403573e+00 3.36993179e+00 -0.62584106 0.78188876 819.50 2.15487112e+00 -2.17742600e+00 3.06343819e+00 -0.79060434 0.72399971 819.75 1.34639584e+00 -2.55200528e+00 2.88539645e+00 -1.08532621 0.71204431 820.00 8.69427698e-01 -2.41708180e+00 2.56869402e+00 -1.22550512 0.67298274 820.25 1.12980955e-01 -1.74279888e+00 1.74645717e+00 -1.50605961 0.48635419 820.50 2.35171054e-03 -1.28209272e+00 1.28209488e+00 -1.56896205 0.39888283 820.75 1.64735699e-02 -1.01077295e+00 1.01090719e+00 -1.55449978 0.44806885 821.00 -3.81238650e-02 -8.14961667e-01 8.15852896e-01 -1.61754220 0.41818949 821.25 -6.89151133e-03 -6.40715816e-01 6.40752877e-01 -1.58155187 0.35363563 821.50 8.93450526e-02 -6.11212589e-01 6.17708157e-01 -1.42564761 0.33658652 821.75 8.23085893e-02 -5.84139869e-01 5.89910239e-01 -1.43081229 0.29518636 822.00 -1.93438781e-02 -4.47917053e-01 4.48334554e-01 -1.61395580 0.26442014 822.25 -6.62315407e-02 -2.68507611e-01 2.76555517e-01 -1.81263410 0.12463154 822.50 -2.43542226e-01 -9.00843715e-02 2.59669039e-01 -2.78730755 0.13945220 822.75 -2.47279466e-01 1.46118821e-01 2.87224379e-01 2.60788705 0.17665783 823.00 -2.35155947e-01 2.39109397e-01 3.35367892e-01 2.34785874 0.35045217 823.25 -1.65851643e-01 2.79353457e-01 3.24877086e-01 2.10656926 0.34303606 823.50 -2.56314052e-01 4.32453662e-01 5.02705742e-01 2.10582878 0.60648924 823.75 -3.10709754e-01 6.05512913e-01 6.80578018e-01 2.04489648 0.69917739 824.00 -1.39026955e-01 9.36214200e-01 9.46480598e-01 1.71821807 0.76303126 824.25 1.26646218e-02 1.16101649e+00 1.16108556e+00 1.55988854 0.82700449 824.50 3.81380852e-01 1.30820545e+00 1.36266389e+00 1.28712837 0.84832694 824.75 6.27474585e-01 1.38349507e+00 1.51913889e+00 1.14499990 0.92099885 825.00 8.53296638e-01 1.30056322e+00 1.55549987e+00 0.99014638 0.87340966 825.25 1.08401913e+00 1.22174948e+00 1.63333073e+00 0.84506022 0.84066317 825.50 1.48680583e+00 8.46334534e-01 1.71081084e+00 0.51748719 0.86558349 825.75 1.61727024e+00 7.25800847e-01 1.77266745e+00 0.42184010 0.89989058 826.00 1.73411815e+00 4.82793728e-01 1.80007098e+00 0.27153256 0.85435341 826.25 1.77328674e+00 2.59779071e-01 1.79221401e+00 0.14546111 0.88807263 826.50 1.54493722e+00 8.80681395e-02 1.54744532e+00 0.05694272 0.85601068 826.75 1.40688935e+00 -1.82902795e-02 1.40700823e+00 -0.01299978 0.84940966 827.00 1.27982632e+00 -1.26785092e-01 1.28609093e+00 -0.09874213 0.85899731 827.25 1.22807495e+00 -1.87189685e-01 1.24225926e+00 -0.15126102 0.89652472 827.50 1.14676456e+00 -3.23855658e-01 1.19161715e+00 -0.27524038 0.90393353 827.75 1.07435002e+00 -4.13204104e-01 1.15107150e+00 -0.36716780 0.90464971 828.00 9.68247312e-01 -4.04596274e-01 1.04938125e+00 -0.39581141 0.91586805 828.25 8.42609185e-01 -3.80328456e-01 9.24467399e-01 -0.42399258 0.89987701 828.50 7.45662787e-01 -3.79857958e-01 8.36842315e-01 -0.47115776 0.92437747 828.75 7.02566913e-01 -4.32424059e-01 8.24979293e-01 -0.55173260 0.91583109 829.00 4.72884051e-01 -4.08520679e-01 6.24906770e-01 -0.71250392 0.83423668 829.25 3.49403117e-01 -3.48457550e-01 4.93462463e-01 -0.78404321 0.79624652 829.50 2.15212351e-01 -2.75937835e-01 3.49940059e-01 -0.90841321 0.67340793 829.75 1.51182434e-01 -1.94065936e-01 2.46003487e-01 -0.90897581 0.48947565 830.00 7.74418337e-02 -2.98212254e-02 8.29851981e-02 -0.36757766 0.09431349 830.25 9.19159094e-02 7.03869060e-02 1.15770683e-01 0.65352090 0.15604963 830.50 1.44333991e-01 2.21265059e-01 2.64178968e-01 0.99279708 0.53383790 830.75 1.85723666e-01 2.77817297e-01 3.34179189e-01 0.98151859 0.65581611 831.00 2.38978890e-01 2.82491243e-01 3.70016503e-01 0.86864701 0.69134102 831.25 2.71510164e-01 2.92024981e-01 3.98743474e-01 0.82178589 0.72859783 831.50 2.97978000e-01 3.23602898e-01 4.39897401e-01 0.82660019 0.78484008 831.75 2.81709330e-01 3.29767876e-01 4.33713037e-01 0.86383111 0.75847231 832.00 2.36546958e-01 3.00969523e-01 3.82801668e-01 0.90468144 0.64314143 832.25 2.72660440e-01 3.47797313e-01 4.41935161e-01 0.90591044 0.64980505 832.50 3.29474686e-01 3.48855948e-01 4.79847935e-01 0.81396239 0.67817475 832.75 3.20129158e-01 3.22541864e-01 4.54440240e-01 0.78915233 0.64178780 833.00 3.04413121e-01 3.00374991e-01 4.27659307e-01 0.77872133 0.63456867 833.25 3.51494639e-01 2.58284856e-01 4.36187515e-01 0.63371411 0.49101971 833.50 3.42136084e-01 2.28455286e-01 4.11398733e-01 0.58873993 0.42297408 833.75 3.06226593e-01 2.01226032e-01 3.66424129e-01 0.58136060 0.37563959 834.00 2.31096404e-01 1.26615195e-01 2.63508929e-01 0.50122109 0.21027617 834.25 1.77349403e-01 5.85203066e-02 1.86755019e-01 0.31872215 0.07388468 834.50 2.37594950e-01 8.32997686e-02 2.51774128e-01 0.33720541 0.11947855 834.75 2.28379706e-01 8.53177479e-03 2.28539015e-01 0.03734049 0.09503918 835.00 1.95602766e-01 -5.67118232e-02 2.03658226e-01 -0.28219621 0.09045903 835.25 5.87069088e-02 2.11575415e-02 6.24030665e-02 0.34590318 0.00699324 835.50 8.30986514e-02 -2.09017958e-02 8.56870523e-02 -0.24641805 0.01221182 835.75 8.48855953e-02 -4.36867430e-02 9.54677736e-02 -0.47530226 0.01491476 836.00 6.14902612e-02 4.17705249e-03 6.16319721e-02 0.06782611 0.00539327 836.25 4.32417851e-02 1.70105136e-01 1.75515268e-01 1.32186280 0.03245298 836.50 1.83481762e-02 2.50957841e-01 2.51627689e-01 1.49781360 0.05439234 836.75 1.24627569e-03 1.49759858e-01 1.49765043e-01 1.56247469 0.01031347 837.00 -1.87946356e-01 1.80389913e-01 2.60507876e-01 2.37670668 0.02712313 837.25 -2.23027094e-01 4.00128965e-01 4.58087626e-01 2.07929403 0.06299222 837.50 -4.94387249e-02 3.64594985e-01 3.67931638e-01 1.70557331 0.03372209 837.75 6.92375871e-02 4.42628975e-01 4.48011443e-01 1.41563019 0.03121846 838.00 -5.45152597e-02 6.17205320e-01 6.19608199e-01 1.65889368 0.05131582 838.25 4.61206609e-01 7.96240342e-01 9.20168581e-01 1.04578860 0.04568704 838.50 1.21851485e+00 9.04225216e-01 1.51736670e+00 0.63840757 0.09742235 838.75 2.77453314e+00 1.51789409e+00 3.16259966e+00 0.50059930 0.24866284 839.00 3.98231625e+00 9.44824783e-01 4.09286411e+00 0.23294795 0.35812325 839.25 4.90275730e+00 -1.36277262e-01 4.90465092e+00 -0.02778889 0.55905989 839.50 4.97702247e+00 -9.01135831e-01 5.05794410e+00 -0.17911873 0.63719097 839.75 4.55670627e+00 -1.77711925e+00 4.89098404e+00 -0.37185680 0.58835210 840.00 3.75292226e+00 -1.84353460e+00 4.18127317e+00 -0.45660415 0.54487794 840.25 3.47435094e+00 -2.38441047e+00 4.21384951e+00 -0.60146488 0.56609577 840.50 2.36363248e+00 -2.30698274e+00 3.30286661e+00 -0.77326979 0.40788239 840.75 1.74742439e+00 -2.66142709e+00 3.18381628e+00 -0.98981339 0.35540875 841.00 1.37765509e+00 -3.27356038e+00 3.55163781e+00 -1.17245193 0.48809018 841.25 8.71337697e-01 -3.23620378e+00 3.35145406e+00 -1.30778659 0.56313055 841.50 4.79220192e-01 -3.14920237e+00 3.18545563e+00 -1.41978293 0.59206884 841.75 4.89670826e-01 -3.41256498e+00 3.44751755e+00 -1.42827859 0.69786489 842.00 4.50267851e-01 -3.27104358e+00 3.30188843e+00 -1.43400334 0.72833716 842.25 2.49733144e-01 -2.92894418e+00 2.93957150e+00 -1.48573817 0.71566045 842.50 -1.11615732e-01 -2.68986821e+00 2.69218296e+00 -1.61226741 0.73099846 842.75 -6.61356826e-02 -2.41292957e+00 2.41383575e+00 -1.59819834 0.76373200 843.00 -2.96440827e-01 -2.13626005e+00 2.15672997e+00 -1.70868205 0.65432083 843.25 -5.66902828e-01 -2.03170786e+00 2.10931639e+00 -1.84290322 0.69934489 843.50 -8.49780352e-01 -2.23490069e+00 2.39100559e+00 -1.93414589 0.83704509 843.75 -9.96420772e-01 -2.32697184e+00 2.53133410e+00 -1.97537843 0.82817016 844.00 -1.15567989e+00 -2.15279560e+00 2.44338390e+00 -2.06347008 0.79927031 844.25 -1.56354274e+00 -2.11413523e+00 2.62949304e+00 -2.20758623 0.80429967 844.50 -1.93997579e+00 -2.05785551e+00 2.82812223e+00 -2.32671711 0.75472618 844.75 -2.30321393e+00 -1.78227962e+00 2.91226974e+00 -2.48301842 0.71833731 845.00 -2.98157770e+00 -1.06400983e+00 3.16574202e+00 -2.79881840 0.70638686 845.25 -3.26630434e+00 -3.31840590e-01 3.28311776e+00 -3.04034492 0.68544741 845.50 -3.39343625e+00 5.69659134e-01 3.44091865e+00 2.97527254 0.64743376 845.75 -3.63073601e+00 1.41141670e+00 3.89542567e+00 2.77082965 0.68642191 846.00 -2.04643402e+00 2.69126136e+00 3.38094364e+00 2.22092001 0.51410862 846.25 -9.30057224e-01 2.82073598e+00 2.97011075e+00 1.88929269 0.51453620 846.50 -7.45201342e-01 1.92100104e+00 2.06047811e+00 1.94084873 0.67566531 846.75 -7.35723940e-01 1.83284530e+00 1.97499661e+00 1.95251834 0.73554543 847.00 -8.00925615e-01 1.56562438e+00 1.75859647e+00 2.04365661 0.69957420 847.25 -9.58675268e-01 1.29177917e+00 1.60864903e+00 2.20924517 0.65657090 847.50 -1.08647907e+00 1.24865149e+00 1.65516383e+00 2.28685685 0.70571340 847.75 -1.12770200e+00 1.06953130e+00 1.55422296e+00 2.38266283 0.66335554 848.00 -1.48817166e+00 1.21624778e+00 1.92195566e+00 2.45640566 0.70781579 848.25 -1.57560857e+00 1.19693325e+00 1.97868431e+00 2.49193516 0.75944489 848.50 -1.64770711e+00 1.43800521e+00 2.18696084e+00 2.42404915 0.80224731 848.75 -1.55849316e+00 1.53396783e+00 2.18676891e+00 2.36412501 0.81100759 849.00 -1.37596021e+00 1.53235090e+00 2.05945764e+00 2.30247252 0.80705720 849.25 -1.38496081e+00 1.58466513e+00 2.10458547e+00 2.28904661 0.82592074 849.50 -1.38391735e+00 1.39138348e+00 1.96244114e+00 2.35350429 0.81498843 849.75 -1.34195586e+00 1.26314406e+00 1.84292660e+00 2.38643816 0.79566931 850.00 -1.58138777e+00 1.06332291e+00 1.90563451e+00 2.54963228 0.81935918 850.25 -1.55862943e+00 9.05696810e-01 1.80266814e+00 2.61519706 0.85346697 850.50 -1.86427093e+00 6.17652578e-01 1.96392485e+00 2.82166373 0.84579056 850.75 -2.01975048e+00 6.38525215e-01 2.11827912e+00 2.83539449 0.86871829 851.00 -2.12454215e+00 4.97473743e-01 2.18200813e+00 2.91158092 0.88378000 851.25 -2.24877790e+00 3.08687444e-01 2.26986563e+00 3.00517623 0.87509546 851.50 -2.32094216e+00 2.83865579e-01 2.33823698e+00 3.01989090 0.83673949 851.75 -2.28664093e+00 1.89324147e-01 2.29446516e+00 3.05898532 0.80293825 852.00 -2.58931744e+00 -6.65361118e-03 2.58932599e+00 -3.13902302 0.83697342 852.25 -2.47378693e+00 -2.32445127e-01 2.48468359e+00 -3.04790446 0.83964379 852.50 -2.26530269e+00 -4.72883222e-01 2.31413371e+00 -2.93579742 0.78008330 852.75 -2.49554399e+00 -7.29812959e-01 2.60007053e+00 -2.85708006 0.80131360 853.00 -2.53782814e+00 -1.11851227e+00 2.77338086e+00 -2.72646931 0.84835219 853.25 -2.13128126e+00 -1.36737150e+00 2.53220549e+00 -2.57116468 0.79405830 853.50 -1.62453063e+00 -1.69483942e+00 2.34767554e+00 -2.33501629 0.79275082 853.75 -1.41837476e+00 -2.06730461e+00 2.50709699e+00 -2.17213142 0.82201162 854.00 -1.18116010e+00 -2.53318870e+00 2.79502847e+00 -2.00710102 0.85084788 854.25 -9.14425383e-01 -3.07039976e+00 3.20367422e+00 -1.86025160 0.80539406 854.50 -7.80050499e-01 -3.53466116e+00 3.61971108e+00 -1.78800094 0.77036392 854.75 -1.24523474e+00 -3.64340749e+00 3.85032826e+00 -1.90012729 0.72195538 855.00 -1.74110888e+00 -3.87469336e+00 4.24790640e+00 -1.99311289 0.60034720 855.25 -1.44932692e+00 -3.95490551e+00 4.21210472e+00 -1.92206167 0.54672104 855.50 -1.34295051e+00 -3.03564340e+00 3.31943473e+00 -1.98730715 0.37529408 855.75 -1.23041035e+00 -3.33287848e+00 3.55274382e+00 -1.92444906 0.59407115 856.00 -1.65793625e+00 -3.78343963e+00 4.13075877e+00 -1.98380148 0.66687111 856.25 -1.82060373e+00 -3.67206862e+00 4.09862000e+00 -2.03107657 0.63507707 856.50 -1.88431512e+00 -3.87171684e+00 4.30590696e+00 -2.02373711 0.61822368 856.75 -1.88689992e+00 -3.60319038e+00 4.06735445e+00 -2.05320388 0.61076119 857.00 -1.59553504e+00 -3.27029481e+00 3.63875806e+00 -2.02470684 0.53353756 857.25 -1.59377074e+00 -3.38851533e+00 3.74461497e+00 -2.01043963 0.42577090 857.50 -1.68461988e+00 -3.60482417e+00 3.97903272e+00 -2.00796291 0.53685783 857.75 -3.10316407e+00 -3.91898366e+00 4.99880587e+00 -2.24053492 0.66961343 858.00 -3.51155395e+00 -4.19834927e+00 5.47331232e+00 -2.26734937 0.67859309 858.25 -3.24553075e+00 -3.16306284e+00 4.53193517e+00 -2.36906211 0.66703836 858.50 -3.32455358e+00 -2.69674384e+00 4.28078075e+00 -2.46008397 0.66710361 858.75 -2.86944300e+00 -2.50198394e+00 3.80704961e+00 -2.42449802 0.63040022 859.00 -2.78884247e+00 -2.72257679e+00 3.89744361e+00 -2.36821725 0.65244086 859.25 -2.29098146e+00 -2.96891599e+00 3.75007442e+00 -2.22801375 0.61822638 859.50 -2.15556193e+00 -3.13830827e+00 3.80728591e+00 -2.17264538 0.61760319 859.75 -2.81175401e+00 -3.77711324e+00 4.70877320e+00 -2.21071587 0.74656012 860.00 -2.71101728e+00 -4.10944081e+00 4.92312081e+00 -2.15396359 0.75195949 860.25 -2.83381134e+00 -3.82326282e+00 4.75897314e+00 -2.20864311 0.78404365 860.50 -3.21613125e+00 -3.07584132e+00 4.45020224e+00 -2.37848745 0.79018146 860.75 -3.50767062e+00 -3.02264410e+00 4.63034886e+00 -2.43033143 0.82622607 861.00 -3.42008747e+00 -2.94054924e+00 4.51041330e+00 -2.43144368 0.84751820 861.25 -2.91022480e+00 -1.99428417e+00 3.52797077e+00 -2.54082246 0.84373646 861.50 -2.67112151e+00 -1.97250328e+00 3.32049082e+00 -2.50552132 0.88302235 861.75 -2.28325552e+00 -2.14077496e+00 3.12988389e+00 -2.38838942 0.89894762 862.00 -2.04253093e+00 -2.36587072e+00 3.12558425e+00 -2.28297933 0.88159455 862.25 -1.69143824e+00 -2.61046389e+00 3.11054417e+00 -2.14572588 0.90756606 862.50 -1.51894504e+00 -2.77344491e+00 3.16214969e+00 -2.07185237 0.88975692 862.75 -1.32834199e+00 -3.21325240e+00 3.47699345e+00 -1.96279639 0.91372939 863.00 -1.53817277e+00 -3.36961323e+00 3.70408812e+00 -1.99902882 0.90966976 863.25 -2.09512652e+00 -3.78135049e+00 4.32298122e+00 -2.07675764 0.90081776 863.50 -2.34289002e+00 -3.77588613e+00 4.44369775e+00 -2.12614409 0.90099338 863.75 -2.54162238e+00 -3.68259392e+00 4.47452146e+00 -2.17489566 0.91928189 864.00 -2.58911572e+00 -3.58475269e+00 4.42198734e+00 -2.19630477 0.93983695 864.25 -2.70627323e+00 -3.50620636e+00 4.42915317e+00 -2.22813681 0.94733732 864.50 -2.82251373e+00 -3.42060209e+00 4.43476069e+00 -2.26068630 0.93165513 864.75 -2.91166085e+00 -3.40194850e+00 4.47783681e+00 -2.27869434 0.93614229 865.00 -3.16481168e+00 -3.23489824e+00 4.52554965e+00 -2.34524341 0.93878258 865.25 -3.44936283e+00 -2.79826991e+00 4.44166843e+00 -2.46003399 0.94909628 865.50 -3.40540945e+00 -2.57820790e+00 4.27129600e+00 -2.49356816 0.95981568 865.75 -3.43466941e+00 -2.52074859e+00 4.26041400e+00 -2.50846696 0.97275165 866.00 -3.40671515e+00 -2.34114397e+00 4.13360172e+00 -2.53949922 0.97451931 866.25 -3.43576726e+00 -2.13687829e+00 4.04607779e+00 -2.58518901 0.97914906 866.50 -3.25272825e+00 -1.96099274e+00 3.79812238e+00 -2.59906092 0.98217023 866.75 -3.21586017e+00 -1.79970252e+00 3.68519820e+00 -2.63138351 0.98691430 867.00 -3.11010550e+00 -1.59958705e+00 3.49734684e+00 -2.66655540 0.98194442 867.25 -3.08346223e+00 -1.50984238e+00 3.43327298e+00 -2.68625271 0.98209400 867.50 -2.88682232e+00 -1.47096158e+00 3.23998010e+00 -2.67033942 0.97831043 867.75 -2.74146921e+00 -1.42369028e+00 3.08910139e+00 -2.66261151 0.97815203 868.00 -2.67796469e+00 -1.27886378e+00 2.96765690e+00 -2.69606527 0.97648735 868.25 -2.64261749e+00 -1.23650297e+00 2.91759606e+00 -2.70394629 0.98089749 868.50 -2.43669919e+00 -1.16008721e+00 2.69875995e+00 -2.69725565 0.98166447 868.75 -2.38176685e+00 -1.14962001e+00 2.64470027e+00 -2.69190062 0.97571432 869.00 -2.31287071e+00 -1.15699447e+00 2.58611816e+00 -2.67775167 0.95123466 869.25 -2.22271812e+00 -1.18212539e+00 2.51751788e+00 -2.65280044 0.96434653 869.50 -2.19018527e+00 -1.20952670e+00 2.50197249e+00 -2.63702473 0.96238331 869.75 -2.17580382e+00 -1.22148537e+00 2.49522520e+00 -2.63004300 0.95877979 870.00 -2.10364729e+00 -1.26302816e+00 2.45368541e+00 -2.60087967 0.95082169 870.25 -2.05255478e+00 -1.30366076e+00 2.43156586e+00 -2.57573447 0.93277081 870.50 -1.97385879e+00 -1.51066212e+00 2.48560225e+00 -2.48834952 0.95286750 870.75 -2.10983196e+00 -1.55404823e+00 2.62039249e+00 -2.50673944 0.96411675 871.00 -2.22347530e+00 -1.50895634e+00 2.68715307e+00 -2.54534131 0.96319682 871.25 -2.22287785e+00 -1.45434340e+00 2.65636982e+00 -2.56222748 0.96455134 871.50 -2.16374428e+00 -1.48181924e+00 2.62251360e+00 -2.54111362 0.94692696 871.75 -2.26764367e+00 -1.49172238e+00 2.71430350e+00 -2.55973323 0.95157278 872.00 -2.33640390e+00 -1.50744903e+00 2.78050099e+00 -2.56859880 0.97137168 872.25 -2.39060595e+00 -1.55841884e+00 2.85371093e+00 -2.56388796 0.96661399 872.50 -2.60916379e+00 -1.67865254e+00 3.10251673e+00 -2.56989377 0.96001004 872.75 -2.89125031e+00 -1.56889568e+00 3.28949266e+00 -2.64442098 0.94422800 873.00 -3.08084214e+00 -1.26319033e+00 3.32975045e+00 -2.75248290 0.95392736 873.25 -2.98433063e+00 -1.00212187e+00 3.14809110e+00 -2.81762867 0.94552827 873.50 -2.87125770e+00 -6.47498673e-01 2.94336123e+00 -2.91979239 0.94909355 873.75 -2.76472932e+00 -5.49999913e-01 2.81890548e+00 -2.94522187 0.93004542 874.00 -2.72820143e+00 -4.41541307e-01 2.76370074e+00 -2.98114055 0.95061390 874.25 -2.66417875e+00 -4.18144693e-01 2.69679317e+00 -2.98591199 0.95951225 874.50 -2.57044040e+00 -4.01065424e-01 2.60154133e+00 -2.98681082 0.97115128 874.75 -2.60563517e+00 -3.21756566e-01 2.62542605e+00 -3.01872974 0.95438908 875.00 -2.75484091e+00 -1.72772390e-01 2.76025338e+00 -3.07895876 0.95851114 875.25 -2.66011696e+00 -6.68200317e-03 2.66012536e+00 -3.13908074 0.95799894 875.50 -2.52176421e+00 1.29953101e-01 2.52511040e+00 3.09010558 0.95519858 875.75 -2.34918936e+00 3.12700649e-01 2.36990978e+00 3.00926054 0.94680778 876.00 -2.20468811e+00 3.75767662e-01 2.23648184e+00 2.97277461 0.95057885 876.25 -1.85231885e+00 4.72440492e-01 1.91161846e+00 2.89186340 0.89029555 876.50 -1.58673745e+00 5.04891954e-01 1.66512811e+00 2.83352789 0.88126178 876.75 -1.19617644e+00 4.76916551e-01 1.28774511e+00 2.76220674 0.79309153 877.00 -9.94916300e-01 3.80674759e-01 1.06525664e+00 2.77615833 0.74552482 877.25 -7.81143349e-01 1.51113383e-01 7.95625657e-01 2.95050155 0.51695645 877.50 -5.75561919e-01 -1.94869779e-02 5.75891713e-01 -3.10774827 0.44240527 877.75 -4.73531594e-01 -1.94922169e-01 5.12080875e-01 -2.75109653 0.37130639 878.00 -3.28610494e-01 -3.24829194e-01 4.62059371e-01 -2.36198119 0.31086545 878.25 -2.43779485e-01 -5.27844430e-01 5.81419108e-01 -2.00345237 0.32557246 878.50 -2.34720630e-01 -6.90748600e-01 7.29539171e-01 -1.89836107 0.45447857 878.75 -1.54744378e-02 -1.09472930e+00 1.09483866e+00 -1.58493079 0.67081903 879.00 1.88821190e-02 -1.19523525e+00 1.19538439e+00 -1.55499981 0.73671179 879.25 -5.18181463e-02 -1.40127119e+00 1.40222897e+00 -1.60775887 0.74530729 879.50 -8.40393511e-02 -1.63830945e+00 1.64046349e+00 -1.62204779 0.77204031 879.75 -7.50720174e-02 -1.85678818e+00 1.85830519e+00 -1.61120543 0.79083216 880.00 2.42722812e-02 -1.94291083e+00 1.94306244e+00 -1.55830424 0.79646588 880.25 2.66773498e-01 -2.11700267e+00 2.13374515e+00 -1.44544235 0.75342570 880.50 3.62109953e-01 -2.17572003e+00 2.20564758e+00 -1.40587575 0.72458409 880.75 9.06940477e-01 -2.11164724e+00 2.29817212e+00 -1.16512512 0.68767175 881.00 1.35457676e+00 -2.24288138e+00 2.62018990e+00 -1.02748122 0.67490683 881.25 2.37484507e+00 -2.60760112e+00 3.52696367e+00 -0.83207944 0.58064788 881.50 3.45626763e+00 -1.89973679e+00 3.94395560e+00 -0.50257430 0.52356765 881.75 5.93465274e+00 -3.37841883e-01 5.94426112e+00 -0.05686561 0.58624000 882.00 6.62253199e+00 1.75406195e+00 6.85088777e+00 0.25891747 0.47489822 882.25 5.74747928e+00 6.97483361e+00 9.03779962e+00 0.88157311 0.53206982 882.50 2.55976487e+00 8.09893918e+00 8.49383377e+00 1.26466989 0.56521499 882.75 -3.42301295e-01 7.90556448e+00 7.91297163e+00 1.61406808 0.71238436 883.00 -1.95061649e+00 7.29109080e+00 7.54751016e+00 1.83220853 0.77541727 883.25 -2.27579720e+00 6.49204681e+00 6.87938404e+00 1.90796244 0.86079161 883.50 -2.24562920e+00 5.68109348e+00 6.10881934e+00 1.94722813 0.87235821 883.75 -2.26334190e+00 5.05489547e+00 5.53847314e+00 1.99177963 0.91103774 884.00 -2.12211747e+00 4.66796375e+00 5.12769619e+00 1.99747988 0.90904982 884.25 -2.14526086e+00 4.07335989e+00 4.60373815e+00 2.05554091 0.92240414 884.50 -2.18853684e+00 3.62736683e+00 4.23644705e+00 2.11366836 0.90510659 884.75 -2.36161963e+00 3.25171813e+00 4.01882048e+00 2.19893532 0.91648635 885.00 -2.73988945e+00 3.01845442e+00 4.07652564e+00 2.30785629 0.90617334 885.25 -2.82840252e+00 2.63234251e+00 3.86381779e+00 2.39208260 0.88690904 885.50 -2.92386598e+00 2.45709888e+00 3.81920505e+00 2.44272202 0.85179763 885.75 -3.16530649e+00 2.42163004e+00 3.98540553e+00 2.48852647 0.82925806 886.00 -3.41204793e+00 2.45600844e+00 4.20405144e+00 2.51769818 0.73263546 886.25 -3.43750129e+00 2.94903643e+00 4.52915345e+00 2.43252939 0.67551464 886.50 -2.71251251e+00 3.63182056e+00 4.53297305e+00 2.21229382 0.59896154 886.75 -1.72641693e+00 3.63628794e+00 4.02530811e+00 2.01406069 0.56606594 887.00 -1.07114460e+00 3.52566926e+00 3.68479232e+00 1.86574772 0.62400192 887.25 -1.12013771e+00 3.13267945e+00 3.32691885e+00 1.91419494 0.69318076 887.50 -1.11560356e+00 2.18142890e+00 2.45014354e+00 2.04352985 0.59487246 887.75 -1.19325715e+00 2.07153306e+00 2.39063000e+00 2.09340142 0.60893724 888.00 -1.51026844e+00 2.14469514e+00 2.62309511e+00 2.18432746 0.61670553 888.25 -1.56049466e+00 2.03455750e+00 2.56409200e+00 2.22508557 0.51480729 888.50 -1.51417231e+00 1.47493010e+00 2.11379672e+00 2.36932216 0.38073691 888.75 -1.49389598e+00 1.08532524e+00 1.84652541e+00 2.51329766 0.27848229 889.00 -1.91107678e+00 1.57309848e+00 2.47524813e+00 2.45289575 0.24285366 889.25 -1.95377018e+00 1.81889665e+00 2.66938250e+00 2.39192945 0.22235637 889.50 -4.67236684e-01 1.05577005e+00 1.15453909e+00 1.98744206 0.04890237 889.75 5.91252308e-01 6.10651084e-01 8.49984728e-01 0.80153681 0.02002972 890.00 9.58791103e-01 -1.19279611e+00 1.53037347e+00 -0.89373161 0.02675260 890.25 3.49382511e-02 -3.99007124e+00 3.99022420e+00 -1.56204025 0.13968841 890.50 -4.13864482e+00 -5.05748148e+00 6.53502103e+00 -2.25660938 0.56159038 890.75 -5.15333303e+00 -4.56918462e+00 6.88725558e+00 -2.41620436 0.74123842 891.00 -4.64953382e+00 -1.87873510e+00 5.01475925e+00 -2.75758296 0.69533246 891.25 -4.22921140e+00 -1.58953533e+00 4.51805839e+00 -2.78207984 0.68674802 891.50 -3.75591312e+00 -1.73025071e+00 4.13529333e+00 -2.70989794 0.65974338 891.75 -3.91463400e+00 -1.65100576e+00 4.24855026e+00 -2.74247608 0.74383912 892.00 -3.72332679e+00 -2.00339917e+00 4.22809302e+00 -2.64795721 0.77030314 892.25 -3.69550699e+00 -1.92512712e+00 4.16687969e+00 -2.66133591 0.70989904 892.50 -4.19826479e+00 -2.21777837e+00 4.74804887e+00 -2.65559291 0.68284750 892.75 -4.43952630e+00 -2.84221576e+00 5.27139301e+00 -2.57213264 0.74581438 893.00 -5.76802196e+00 -2.64964824e+00 6.34749660e+00 -2.71097516 0.78951847 893.25 -6.47494165e+00 -2.06240485e+00 6.79546784e+00 -2.83323191 0.82270435 893.50 -6.96415126e+00 -1.43836329e+00 7.11113857e+00 -2.93791834 0.87992761 893.75 -6.55282402e+00 -1.21187069e+00 6.66394276e+00 -2.95872017 0.86145366 894.00 -6.94566993e+00 -5.50367737e-01 6.96744110e+00 -3.06251890 0.86130059 894.25 -7.14753575e+00 -2.75896028e-02 7.14758900e+00 -3.13773266 0.87466674 894.50 -6.89143063e+00 -1.87488706e-01 6.89398057e+00 -3.11439330 0.86485396 894.75 -6.82145307e+00 1.20174523e-01 6.82251156e+00 3.12397733 0.84535227 895.00 -7.13856798e+00 1.23996013e-01 7.13964480e+00 3.12422453 0.86755250 895.25 -7.07509327e+00 6.67657984e-01 7.10652602e+00 3.04750391 0.87609744 895.50 -6.71283271e+00 7.36915959e-01 6.75315986e+00 3.03225327 0.84894382 895.75 -6.58036179e+00 8.12775448e-01 6.63036690e+00 3.01869977 0.88158744 896.00 -6.88181045e+00 1.01975639e+00 6.95695466e+00 2.99448175 0.90706027 896.25 -6.98664413e+00 1.09074175e+00 7.07127384e+00 2.98672465 0.90848132 896.50 -6.69786385e+00 1.13575984e+00 6.79347706e+00 2.97362000 0.90477860 896.75 -6.74184221e+00 1.55650653e+00 6.91918702e+00 2.91469568 0.89817427 897.00 -6.79085432e+00 1.41759078e+00 6.93723764e+00 2.93579797 0.92143360 897.25 -6.99813462e+00 1.62549769e+00 7.18443672e+00 2.91336383 0.93727320 897.50 -6.79971419e+00 1.92526449e+00 7.06701892e+00 2.86567551 0.94134132 897.75 -6.47405811e+00 2.31995577e+00 6.87718134e+00 2.79750168 0.91122695 898.00 -6.45488144e+00 2.56124560e+00 6.94445631e+00 2.76385481 0.88544201 898.25 -5.78637818e+00 3.05793581e+00 6.54470349e+00 2.65542815 0.81077826 898.50 -5.68345197e+00 3.37437159e+00 6.60969061e+00 2.60580457 0.76661532 898.75 -5.18231236e+00 3.28334591e+00 6.13487749e+00 2.57685598 0.71464436 899.00 -4.71170170e+00 3.09522115e+00 5.63742201e+00 2.56036664 0.68250551 899.25 -4.03132619e+00 2.67305693e+00 4.83702638e+00 2.55608324 0.62712054 899.50 -4.11391402e+00 2.63396092e+00 4.88487857e+00 2.57209739 0.64671679 899.75 -3.56336954e+00 2.50896685e+00 4.35804052e+00 2.52812062 0.66879349 900.00 -2.87314290e+00 2.53220271e+00 3.82975204e+00 2.41918568 0.63626901 900.25 -2.67518634e+00 1.93500123e+00 3.30164379e+00 2.51539010 0.54054457 900.50 -2.54473162e+00 2.17068737e+00 3.34477842e+00 2.43535239 0.50753731 900.75 -2.49756703e+00 2.48943168e+00 3.52634530e+00 2.35782580 0.52191138 901.00 -2.56686914e+00 2.37737214e+00 3.49867339e+00 2.39450255 0.53754244 901.25 -2.24256572e+00 2.75346465e+00 3.55115032e+00 2.25428775 0.60210888 901.50 -2.18662713e+00 2.52525225e+00 3.34039476e+00 2.28445158 0.62728282 901.75 -2.31908955e+00 2.86921118e+00 3.68924778e+00 2.25055801 0.76750683 902.00 -2.21346943e+00 2.96743659e+00 3.70204360e+00 2.21168093 0.75154609 902.25 -2.52619663e+00 2.85536404e+00 3.81244976e+00 2.29510481 0.81522893 902.50 -2.75398816e+00 2.97369554e+00 4.05306254e+00 2.31785443 0.85725364 902.75 -2.76070931e+00 2.99815347e+00 4.07559077e+00 2.31498675 0.89694802 903.00 -2.47678587e+00 3.12931480e+00 3.99087451e+00 2.24031969 0.88199961 903.25 -2.13809572e+00 3.59411299e+00 4.18199731e+00 2.10744874 0.90748204 903.50 -2.09823954e+00 3.72673489e+00 4.27681682e+00 2.08358342 0.92462262 903.75 -1.69712900e+00 3.79266190e+00 4.15506091e+00 1.99155015 0.93209878 904.00 -1.64415726e+00 3.81692004e+00 4.15597542e+00 1.97753137 0.93887674 904.25 -1.68153553e+00 3.96117478e+00 4.30330888e+00 1.97224699 0.92653694 904.50 -1.58848513e+00 3.97699108e+00 4.28249262e+00 1.95080160 0.92445183 904.75 -1.42485169e+00 3.91711411e+00 4.16821128e+00 1.91966802 0.95049731 905.00 -1.41033469e+00 4.06375576e+00 4.30152935e+00 1.90484248 0.94776637 905.25 -1.04729449e+00 4.19280899e+00 4.32162851e+00 1.81557121 0.95089207 905.50 -7.74369166e-01 4.13595810e+00 4.20782569e+00 1.75588197 0.96305196 905.75 -6.61217346e-01 4.05999068e+00 4.11348182e+00 1.73224069 0.96961407 906.00 -3.81381250e-01 4.08356650e+00 4.10133723e+00 1.66392035 0.96330633 906.25 -9.44141240e-02 3.98739212e+00 3.98850973e+00 1.59447007 0.96767904 906.50 9.64569060e-02 3.70904840e+00 3.71030241e+00 1.54479635 0.95736342 906.75 3.35263320e-01 3.48447445e+00 3.50056620e+00 1.47487528 0.96017593 907.00 4.12689822e-01 3.35860952e+00 3.38386920e+00 1.44853399 0.95734194 907.25 5.41240905e-01 3.01681949e+00 3.06498639e+00 1.39327708 0.94775322 907.50 5.00374446e-01 2.63891214e+00 2.68593221e+00 1.38340705 0.93264014 907.75 5.55715487e-01 2.31561516e+00 2.38136375e+00 1.33526448 0.92124815 908.00 4.03974069e-01 1.84103996e+00 1.88484036e+00 1.35479253 0.85651468 908.25 2.39005998e-01 1.65903581e+00 1.67616338e+00 1.42771754 0.84496093 908.50 -1.13391743e-02 1.56598360e+00 1.56602466e+00 1.57803713 0.87740726 908.75 -1.28821530e-01 1.46956811e+00 1.47520351e+00 1.65823227 0.89525748 909.00 -3.18548365e-01 1.42906715e+00 1.46414001e+00 1.79011726 0.90894631 909.25 -3.80771131e-01 1.44036621e+00 1.48984612e+00 1.82924131 0.93022693 909.50 -4.69617453e-01 1.43850344e+00 1.51321932e+00 1.88635045 0.94883475 909.75 -4.75723389e-01 1.44696913e+00 1.52316526e+00 1.88843636 0.96165335 910.00 -5.05547405e-01 1.34175411e+00 1.43383482e+00 1.93112747 0.95753541 910.25 -5.14716137e-01 1.29141928e+00 1.39021454e+00 1.95006610 0.96442707 910.50 -5.28134115e-01 1.20382024e+00 1.31457553e+00 1.98422620 0.96981512 910.75 -5.57844500e-01 1.14337549e+00 1.27220203e+00 2.02471123 0.96583057 911.00 -5.38504367e-01 1.08199850e+00 1.20859741e+00 2.03259759 0.94710552 911.25 -5.59273003e-01 1.01924829e+00 1.16260628e+00 2.07264956 0.94111825 911.50 -6.42486044e-01 8.57812399e-01 1.07174177e+00 2.21364560 0.94885751 911.75 -6.54454611e-01 7.67767130e-01 1.00884945e+00 2.27668954 0.94941431 912.00 -7.08277885e-01 5.96398751e-01 9.25931440e-01 2.44173761 0.94143601 912.25 -7.39701606e-01 5.69799186e-01 9.33718147e-01 2.48521965 0.94479656 912.50 -8.02553269e-01 5.15434601e-01 9.53815798e-01 2.57068951 0.93846766 912.75 -8.27028161e-01 4.73148427e-01 9.52809012e-01 2.62193542 0.93172820 913.00 -8.55742019e-01 3.94093311e-01 9.42127349e-01 2.71001807 0.93952070 913.25 -9.22468699e-01 3.52670247e-01 9.87585340e-01 2.77642750 0.94350057 913.50 -9.81376272e-01 2.84763920e-01 1.02185609e+00 2.85918034 0.94182112 913.75 -9.92276534e-01 2.04295926e-01 1.01308911e+00 2.93854386 0.92058325 914.00 -1.04562600e+00 7.27254050e-02 1.04815205e+00 3.07215246 0.89764719 914.25 -1.14300004e+00 2.96486493e-02 1.14338451e+00 3.11565914 0.89423727 914.50 -1.28232693e+00 3.90435280e-03 1.28233288e+00 3.13854792 0.91644329 914.75 -1.32225019e+00 3.64402808e-02 1.32275223e+00 3.11404033 0.91927881 915.00 -1.42261353e+00 7.98976172e-02 1.42485539e+00 3.08548903 0.93066092 915.25 -1.49642561e+00 9.62641983e-02 1.49951872e+00 3.07735175 0.93196876 915.50 -1.53596757e+00 1.19412174e-01 1.54060237e+00 3.06400478 0.94475314 915.75 -1.58978765e+00 2.34561069e-01 1.60699834e+00 2.99510710 0.93246024 916.00 -1.67958879e+00 4.48451317e-01 1.73842661e+00 2.88067847 0.92479562 916.25 -1.63105843e+00 6.31369790e-01 1.74899382e+00 2.77226308 0.90046677 916.50 -1.54005284e+00 9.55561310e-01 1.81241832e+00 2.58625529 0.93027210 916.75 -1.44106642e+00 1.23140350e+00 1.89552816e+00 2.43448699 0.91849648 917.00 -1.24405802e+00 1.64073835e+00 2.05905383e+00 2.21954424 0.91622726 917.25 -8.84904897e-01 2.14060326e+00 2.31629855e+00 1.96279262 0.90394947 917.50 -6.02265074e-01 2.50840410e+00 2.57969269e+00 1.80643482 0.91154821 917.75 -3.32285472e-02 3.02542371e+00 3.02560618e+00 1.58177899 0.89497988 918.00 5.18880306e-01 3.37352479e+00 3.41319590e+00 1.41818276 0.91397206 918.25 1.20499730e+00 3.58981175e+00 3.78665643e+00 1.24694295 0.89994809 918.50 1.80443109e+00 3.98881144e+00 4.37796623e+00 1.14597066 0.90234461 918.75 2.49868507e+00 4.03085302e+00 4.74248913e+00 1.01588013 0.89159029 919.00 3.02807088e+00 4.03449932e+00 5.04444229e+00 0.92694689 0.89533237 919.25 3.48045995e+00 4.79149882e+00 5.92216703e+00 0.94258267 0.86887245 919.50 3.59543295e+00 4.90733142e+00 6.08350555e+00 0.93848184 0.83592034 919.75 3.41760176e+00 4.87492355e+00 5.95356040e+00 0.95936098 0.66624331 920.00 3.85519662e+00 5.98099007e+00 7.11581220e+00 0.99824428 0.66300447 920.25 3.28952500e+00 6.21164832e+00 7.02890814e+00 1.08377069 0.56856260 920.50 2.95170491e+00 5.73812216e+00 6.45279845e+00 1.09569314 0.50360723 920.75 4.20525292e+00 6.36507244e+00 7.62878098e+00 0.98695233 0.53376981 921.00 3.80308840e+00 5.70995895e+00 6.86054755e+00 0.98322438 0.46433731 921.25 4.15471861e+00 3.47627708e+00 5.41721229e+00 0.69672527 0.34790533 921.50 4.13933456e+00 3.56390552e+00 5.46218941e+00 0.71083703 0.43862936 921.75 2.92932402e+00 3.82984015e+00 4.82168174e+00 0.91784710 0.59421938 922.00 2.91926173e+00 3.67984040e+00 4.69716025e+00 0.90014673 0.63315494 922.25 2.92778841e+00 4.14370280e+00 5.07367893e+00 0.95567902 0.70155400 922.50 2.82128711e+00 4.35677663e+00 5.19048780e+00 0.99613623 0.81137292 922.75 2.29253890e+00 4.72796866e+00 5.25446688e+00 1.11931062 0.87006796 923.00 1.58259879e+00 4.97852827e+00 5.22401786e+00 1.26301322 0.85885760 923.25 4.83217255e-01 4.89879621e+00 4.92257079e+00 1.47247439 0.82673196 923.50 3.90361605e-01 4.95138386e+00 4.96674786e+00 1.49212017 0.81455981 923.75 9.23410913e-02 4.75915827e+00 4.76005402e+00 1.55139594 0.82699236 924.00 1.43112789e-01 4.47504228e+00 4.47733009e+00 1.53882701 0.82453310 924.25 -4.61289328e-01 4.07325570e+00 4.09929261e+00 1.68356419 0.84103395 924.50 -8.49783910e-01 3.86464841e+00 3.95697360e+00 1.78723834 0.82589742 924.75 -1.67706412e+00 3.23651532e+00 3.64521268e+00 2.04887380 0.82318842 925.00 -1.96294557e+00 3.25274789e+00 3.79914781e+00 2.11376560 0.84684949 925.25 -2.38720209e+00 3.09919043e+00 3.91199631e+00 2.22714223 0.80567794 925.50 -2.41306492e+00 3.16327227e+00 3.97858942e+00 2.22246338 0.79679975 925.75 -2.39291195e+00 3.14405793e+00 3.95109198e+00 2.22135752 0.76319066 926.00 -2.94178250e+00 3.31034382e+00 4.42859577e+00 2.29731288 0.77463706 926.25 -3.27967729e+00 3.15307204e+00 4.54952156e+00 2.37587331 0.77251710 926.50 -3.39756551e+00 2.98061268e+00 4.51967956e+00 2.42147338 0.72158906 926.75 -3.25274098e+00 3.29347313e+00 4.62896199e+00 2.34997232 0.62981710 927.00 -3.08563653e+00 2.97987286e+00 4.28961479e+00 2.37362962 0.58613059 927.25 -3.45628483e+00 2.95776593e+00 4.54909707e+00 2.43376149 0.61390807 927.50 -3.34918558e+00 3.47344930e+00 4.82513151e+00 2.33798305 0.60028781 927.75 -3.47073619e+00 3.37917507e+00 4.84405139e+00 2.36956045 0.53526341 928.00 -3.13591785e+00 4.32120663e+00 5.33917667e+00 2.19856595 0.63358008 928.25 -2.83989526e+00 4.84270794e+00 5.61398480e+00 2.10117598 0.70358751 928.50 -3.15769547e+00 5.34697869e+00 6.20976826e+00 2.10424348 0.70741909 928.75 -3.16870864e+00 5.25263457e+00 6.13440171e+00 2.11361004 0.59127748 929.00 -1.74265473e+00 5.33325807e+00 5.61074747e+00 1.88661237 0.42602719 929.25 -1.39258202e+00 5.94067825e+00 6.10171638e+00 1.80105350 0.56448988 929.50 5.83284541e-02 6.79222051e+00 6.79247096e+00 1.56220900 0.70066319 929.75 6.29229704e-01 6.62635784e+00 6.65616618e+00 1.47612160 0.72423160 930.00 9.07579123e-01 6.25887608e+00 6.32433630e+00 1.42679332 0.58667857 930.25 4.46801873e-01 5.64754048e+00 5.66518714e+00 1.49184635 0.57865221 930.50 7.31018857e-01 4.55812936e+00 4.61637649e+00 1.41177355 0.58686993 930.75 1.40150864e+00 4.35106863e+00 4.57121698e+00 1.25918348 0.59378040 931.00 1.98352845e+00 3.88764175e+00 4.36441789e+00 1.09901111 0.67460624 931.25 1.96623779e+00 3.86848511e+00 4.33950090e+00 1.10055404 0.69817916 931.50 5.09018235e-01 3.83394971e+00 3.86759226e+00 1.43880224 0.54428964 931.75 4.57192920e-01 3.82166948e+00 3.84891972e+00 1.45173046 0.60670070 932.00 5.73693846e-01 4.03941391e+00 4.07994968e+00 1.42971582 0.70688838 932.25 8.42714748e-01 4.08204244e+00 4.16812171e+00 1.36721199 0.71411820 932.50 9.16719517e-01 3.78952559e+00 3.89883045e+00 1.33344731 0.55006992 932.75 6.13930593e-01 3.24280352e+00 3.30040686e+00 1.38368987 0.39611436 933.00 1.64929533e+00 3.70499108e+00 4.05550663e+00 1.15197880 0.48449042 933.25 1.93634716e+00 3.68361370e+00 4.16154420e+00 1.08682808 0.51724627 933.50 2.35451397e+00 2.95582775e+00 3.77897522e+00 0.89815236 0.50667367 933.75 1.57844055e+00 2.75255003e+00 3.17301217e+00 1.05013023 0.41028478 934.00 1.37797001e+00 2.57263688e+00 2.91843483e+00 1.07905611 0.38384831 934.25 1.67282148e+00 2.59692383e+00 3.08906864e+00 0.99854105 0.38854308 934.50 8.88224472e-01 2.40532871e+00 2.56408832e+00 1.21705546 0.15415140 934.75 7.25749290e-01 1.70491883e+00 1.85295986e+00 1.16835013 0.07508405 935.00 1.25048919e-01 2.45189397e+00 2.45508070e+00 1.51983953 0.09956859 935.25 1.09751504e+00 3.30674298e+00 3.48411946e+00 1.25033441 0.16725304 935.50 1.50037793e+00 6.42151521e-01 1.63202099e+00 0.40440316 0.03337889 935.75 7.62734812e-01 -1.43092296e+00 1.62151315e+00 -1.08106978 0.02608418 936.00 4.25678586e-01 -2.21106882e+00 2.25167218e+00 -1.38060173 0.04636848 936.25 -1.57935233e-01 -1.70949050e+00 1.71677060e+00 -1.66292212 0.02553485 936.50 1.60813946e+00 -2.32050945e+00 2.82327410e+00 -0.96477613 0.07674041 936.75 2.10533123e+00 -3.84313388e+00 4.38201980e+00 -1.06963124 0.19462871 937.00 5.80564118e-01 -4.96842099e+00 5.00222569e+00 -1.45447301 0.23688294 937.25 2.49624201e-01 -5.52458074e+00 5.53021741e+00 -1.52564276 0.31179539 937.50 1.08560707e+00 -4.66783028e+00 4.79240882e+00 -1.34228645 0.26369771 937.75 2.37567554e-01 -4.16261560e+00 4.16938928e+00 -1.51378647 0.19682150 938.00 -7.02755114e-01 -3.59842543e+00 3.66640564e+00 -1.76366395 0.13486562 938.25 -1.17194031e+00 -4.13355869e+00 4.29648130e+00 -1.84706473 0.16472864 938.50 -1.97949726e+00 -5.63767938e+00 5.97510152e+00 -1.90846783 0.38652527 938.75 -2.39553068e+00 -5.01716613e+00 5.55972331e+00 -2.01625549 0.40842229 939.00 -2.87944880e+00 -5.37368278e+00 6.09653115e+00 -2.06270529 0.42139919 939.25 -2.91546208e+00 -4.94011843e+00 5.73626091e+00 -2.10394938 0.38251718 939.50 -4.10001937e+00 -5.03834039e+00 6.49577037e+00 -2.25387371 0.37676425 939.75 -4.26564339e+00 -5.64504396e+00 7.07546711e+00 -2.21789980 0.39572671 940.00 -3.10962348e+00 -5.71080194e+00 6.50253927e+00 -2.06941949 0.41389998 940.25 -4.64361290e+00 -5.24899925e+00 7.00821902e+00 -2.29507491 0.45455763 940.50 -4.07911530e+00 -4.22635874e+00 5.87377987e+00 -2.33846787 0.37932526 940.75 -5.74709791e+00 -3.04165719e+00 6.50236978e+00 -2.65481902 0.44693079 941.00 -6.19983207e+00 -2.97186157e+00 6.87530936e+00 -2.69460476 0.46848638 941.25 -5.85955541e+00 -3.73549941e+00 6.94898162e+00 -2.57405104 0.47456916 941.50 -6.47266630e+00 -3.61909040e+00 7.41574166e+00 -2.63176353 0.51712741 941.75 -7.51778673e+00 -1.46648288e+00 7.65948362e+00 -2.94894345 0.66647331 942.00 -7.89773193e+00 -1.40912299e+00 8.02245581e+00 -2.96502936 0.73812791 942.25 -8.49786970e+00 -8.34114748e-01 8.53870815e+00 -3.04375033 0.79694194 942.50 -8.23458616e+00 -1.09647057e+00 8.30726531e+00 -3.00921703 0.77936190 942.75 -7.65590187e+00 -1.56003216e+00 7.81322813e+00 -2.94057611 0.77480769 943.00 -7.83339819e+00 -2.07644181e+00 8.10393348e+00 -2.88247639 0.84113546 943.25 -8.02221607e+00 -2.23781433e+00 8.32849108e+00 -2.86955590 0.86511723 943.50 -8.00317393e+00 -1.67926573e+00 8.17745231e+00 -2.93476810 0.88416439 943.75 -7.43626578e+00 -7.59393603e-01 7.47493996e+00 -3.03982515 0.86855807 944.00 -7.79542851e+00 -6.39274962e-01 7.82159691e+00 -3.05976936 0.87780795 944.25 -7.83339135e+00 -9.12425970e-01 7.88635158e+00 -3.02563613 0.90496128 944.50 -7.58355479e+00 -3.73933769e-01 7.59276825e+00 -3.09232405 0.88498489 944.75 -6.95242606e+00 7.71742803e-01 6.99512796e+00 3.03104185 0.86069950 945.00 -6.80110399e+00 9.47018557e-01 6.86672117e+00 3.00323744 0.88623868 945.25 -6.42974542e+00 1.01012760e+00 6.50860845e+00 2.98576406 0.92441084 945.50 -6.14190725e+00 1.27276360e+00 6.27239603e+00 2.93725866 0.90343636 945.75 -5.51269716e+00 1.48958980e+00 5.71040346e+00 2.87768444 0.89841862 946.00 -5.12191963e+00 1.59502390e+00 5.36452812e+00 2.83969989 0.89451577 946.25 -4.70598434e+00 1.56222192e+00 4.95851046e+00 2.82107414 0.88027631 946.50 -4.40680313e+00 1.34479516e+00 4.60742746e+00 2.84540552 0.89227226 946.75 -4.30727003e+00 1.30138077e+00 4.49957409e+00 2.84817750 0.94975464 947.00 -3.97322232e+00 1.17495308e+00 4.14330911e+00 2.85406898 0.93269236 947.25 -3.91936674e+00 9.09559273e-01 4.02352255e+00 2.91356113 0.94759264 947.50 -3.77789810e+00 8.58927327e-01 3.87430900e+00 2.91803699 0.95118755 947.75 -3.57575697e+00 7.54029163e-01 3.65439433e+00 2.93376486 0.94778783 948.00 -3.43221298e+00 5.07691277e-01 3.46955852e+00 2.99473803 0.95471188 948.25 -3.47431050e+00 2.15914962e-01 3.48101318e+00 3.07952634 0.96313005 948.50 -3.47199684e+00 2.15017807e-01 3.47864840e+00 3.07974249 0.94237236 948.75 -3.44799405e+00 7.59199701e-02 3.44882977e+00 3.11957762 0.93109423 949.00 -3.44841898e+00 2.03051665e-01 3.45439191e+00 3.08277802 0.92578453 949.25 -3.42082521e+00 3.81285137e-01 3.44200864e+00 3.03059082 0.92706831 949.50 -3.35809541e+00 4.12143701e-01 3.38329236e+00 3.01947199 0.92854815 949.75 -3.18287791e+00 5.50314093e-01 3.23010176e+00 2.97038699 0.91578176 950.00 -2.94073409e+00 3.74338212e-01 2.96446388e+00 3.01497946 0.91472384 950.25 -2.67729093e+00 2.64798030e-01 2.69035401e+00 3.04300807 0.91844914 950.50 -2.44372716e+00 1.79343895e-01 2.45029930e+00 3.06833450 0.87020705 950.75 -2.55116678e+00 -1.96255747e-01 2.55870441e+00 -3.06481603 0.87917843 951.00 -2.76789404e+00 -4.42181788e-01 2.80299165e+00 -2.98317739 0.94020996 951.25 -2.86932508e+00 -4.60944126e-01 2.90611354e+00 -2.98230808 0.95574266 951.50 -3.03546428e+00 -3.39241985e-01 3.05436221e+00 -3.03029499 0.96686652 951.75 -3.08301973e+00 -2.59974811e-01 3.09396147e+00 -3.05746694 0.97632159 952.00 -3.22748841e+00 -1.15540053e-01 3.22955584e+00 -3.10580918 0.96601818 952.25 -3.27219123e+00 -2.43033092e-02 3.27228148e+00 -3.13416556 0.97193108 952.50 -3.32084288e+00 6.82768182e-02 3.32154470e+00 3.12103546 0.97413027 952.75 -3.19064740e+00 1.27059990e-01 3.19317633e+00 3.10179105 0.96938289 953.00 -3.07484826e+00 2.60773292e-01 3.08588634e+00 3.05698660 0.97664941 953.25 -3.03711201e+00 3.06415045e-01 3.05253002e+00 3.04104263 0.97466051 953.50 -2.89848648e+00 3.30901933e-01 2.91731382e+00 3.02792109 0.96517712 953.75 -2.81050896e+00 3.11298552e-01 2.82769648e+00 3.03127996 0.95765674 954.00 -3.02808737e+00 3.75525924e-01 3.05128381e+00 3.01820838 0.95136516 954.25 -2.99443386e+00 4.94834967e-01 3.03504462e+00 2.97782112 0.93229024 954.50 -2.69770263e+00 4.20076680e-01 2.73021316e+00 2.98711679 0.94787401 954.75 -2.65771884e+00 4.22490236e-01 2.69109038e+00 2.98394453 0.95348234 955.00 -2.51550829e+00 4.29112536e-01 2.55184630e+00 2.97263222 0.93239693 955.25 -2.44435595e+00 4.49080259e-01 2.48526640e+00 2.95989755 0.91286857 955.50 -2.41071209e+00 4.83769586e-01 2.45877323e+00 2.94354816 0.88849910 955.75 -2.37298303e+00 4.79205899e-01 2.42088553e+00 2.94233010 0.86104076 956.00 -2.18597930e+00 4.18004034e-01 2.22558596e+00 2.95265301 0.84091060 956.25 -2.13918491e+00 3.97766298e-01 2.17585158e+00 2.95774932 0.84890847 956.50 -2.21454500e+00 3.19633393e-01 2.23749303e+00 2.99824891 0.85956679 956.75 -2.13839604e+00 2.41798573e-01 2.15202327e+00 3.02899617 0.82503845 957.00 -1.92259479e+00 3.08371552e-01 1.94716814e+00 2.98255382 0.83507218 957.25 -2.02050440e+00 2.07183708e-01 2.03109899e+00 3.03940921 0.88146192 957.50 -2.11387369e+00 1.37670145e-01 2.11835196e+00 3.07655755 0.88829097 957.75 -2.12040671e+00 1.39264769e-01 2.12497513e+00 3.07600852 0.84487823 958.00 -2.03809899e+00 8.61072257e-02 2.03991715e+00 3.09936897 0.81868090 958.25 -2.07666449e+00 1.39963502e-02 2.07671166e+00 3.13485293 0.80517319 958.50 -1.87498713e+00 -1.05146011e-01 1.87793302e+00 -3.08557307 0.75457281 958.75 -1.68457970e+00 -2.23338971e-01 1.69932018e+00 -3.00978289 0.67775990 959.00 -1.72797571e+00 -6.67761146e-02 1.72926548e+00 -3.10296774 0.64220657 959.25 -1.65295151e+00 -8.64516438e-02 1.65521074e+00 -3.08933889 0.65086351 959.50 -1.69409980e+00 -2.50501888e-01 1.71252017e+00 -2.99478917 0.71203890 959.75 -1.46932702e+00 -1.59670981e-01 1.47797724e+00 -3.03334794 0.56061980 960.00 -1.37321539e+00 -9.99050253e-02 1.37684477e+00 -3.06896798 0.53955288 960.25 -1.47191242e+00 -3.30849329e-02 1.47228421e+00 -3.11911892 0.44405150 960.50 -1.18098226e+00 7.06718458e-02 1.18309493e+00 3.08182235 0.32229555 960.75 -1.03453031e+00 -1.90349555e-01 1.05189634e+00 -2.95963173 0.33215409 961.00 -1.06686566e+00 -3.19246782e-01 1.11360713e+00 -2.85083506 0.35751575 961.25 -9.19556502e-01 -1.83120525e-01 9.37612546e-01 -2.94502411 0.28917129 961.50 -7.64497785e-01 -2.18663813e-01 7.95154530e-01 -2.86300777 0.20934375 961.75 -7.60402390e-01 -6.97233619e-02 7.63592262e-01 -3.05015562 0.21631832 962.00 -8.87725997e-01 -1.29690440e-01 8.97149405e-01 -2.99652603 0.26163554 962.25 -7.92507871e-01 -6.10689506e-03 7.92531400e-01 -3.13388702 0.18808116 962.50 -9.31003228e-01 2.11187163e-01 9.54655450e-01 2.91852921 0.22472700 962.75 -8.88208007e-01 7.79392092e-02 8.91620987e-01 3.05406801 0.17015444 963.00 -8.57944744e-01 7.84033090e-02 8.61519740e-01 3.05046075 0.21339572 963.25 -8.62207609e-01 1.58806522e-01 8.76710598e-01 2.95944812 0.28472975 963.50 -8.85463616e-01 5.99813346e-02 8.87492860e-01 3.07395595 0.29243169 963.75 -8.30467453e-01 -1.01791799e-01 8.36682593e-01 -3.01962932 0.24961697 964.00 -6.49867430e-01 -1.11306552e-01 6.59330588e-01 -2.97196281 0.17530783 964.25 -8.32454008e-01 -2.11691469e-01 8.58948749e-01 -2.89257283 0.29342047 964.50 -7.63273783e-01 -1.97211544e-01 7.88339560e-01 -2.88874647 0.28905785 964.75 -5.25171405e-01 -9.66408523e-02 5.33989194e-01 -2.95961081 0.22837030 965.00 -4.26475121e-01 -4.25101472e-02 4.28588545e-01 -3.04224292 0.13153293 965.25 -5.22147592e-01 -2.82504405e-01 5.93672340e-01 -2.64565206 0.16453783 965.50 -6.38140411e-01 -4.33033129e-02 6.39607975e-01 -3.07383793 0.21369423 965.75 -6.58396160e-01 -9.05377556e-02 6.64592047e-01 -3.00493714 0.23364035 966.00 -6.37494339e-01 -1.33809181e-01 6.51386160e-01 -2.93469756 0.22102496 966.25 -4.83269775e-01 -2.44842500e-01 5.41754119e-01 -2.67264930 0.16563446 966.50 -6.35895943e-01 -3.63052203e-01 7.32236678e-01 -2.62282231 0.28958587 966.75 -6.07600300e-01 -2.08730231e-01 6.42453449e-01 -2.81069143 0.35441485 967.00 -7.30679199e-01 -2.39526969e-01 7.68937748e-01 -2.82481758 0.37008851 967.25 -8.95977418e-01 -3.47784720e-01 9.61108602e-01 -2.77133260 0.51745988 967.50 -8.56263421e-01 -3.22772340e-01 9.15078701e-01 -2.78110956 0.49921897 967.75 -7.85239969e-01 -3.89127715e-01 8.76368751e-01 -2.68150928 0.52083622 968.00 -9.45666341e-01 -3.60520195e-01 1.01205713e+00 -2.77736776 0.64350491 968.25 -1.02905120e+00 -3.81753260e-01 1.09758003e+00 -2.78635457 0.70497719 968.50 -8.69185305e-01 -3.06274729e-01 9.21567851e-01 -2.80280814 0.55911006 968.75 -8.43988231e-01 -3.32036817e-01 9.06953462e-01 -2.76677669 0.63090832 969.00 -8.68282101e-01 -3.31977272e-01 9.29582011e-01 -2.77640421 0.64462678 969.25 -8.89334883e-01 -3.95675938e-01 9.73383779e-01 -2.72297779 0.74635855 969.50 -9.24880725e-01 -4.07735596e-01 1.01076836e+00 -2.72637213 0.68552803 969.75 -9.10494288e-01 -4.81516904e-01 1.02997979e+00 -2.65513059 0.65218751 970.00 -6.87917031e-01 -4.85551198e-01 8.42015325e-01 -2.52696589 0.56510725 970.25 -6.42804053e-01 -5.11720081e-01 8.21616998e-01 -2.46924974 0.52970238 970.50 -8.88957532e-01 -5.37558877e-01 1.03885275e+00 -2.59771928 0.56172529 970.75 -9.29226067e-01 -5.22891877e-01 1.06624434e+00 -2.62903790 0.59934977 971.00 -1.04399007e+00 -3.92483093e-01 1.11532876e+00 -2.78199354 0.61664103 971.25 -1.04017850e+00 -3.51682517e-01 1.09802181e+00 -2.81555983 0.60718684 971.50 -1.07853311e+00 -3.39060605e-01 1.13057320e+00 -2.83700325 0.55212280 971.75 -1.08526675e+00 -3.08003942e-01 1.12812692e+00 -2.86505923 0.52502209 972.00 -1.04928138e+00 -2.54296350e-01 1.07965645e+00 -2.90382414 0.48661217 972.25 -9.15816960e-01 -2.89959355e-01 9.60623304e-01 -2.83496531 0.43637774 972.50 -6.43052847e-01 -2.38664246e-01 6.85913687e-01 -2.78620818 0.28737540 972.75 -7.42533916e-01 -3.64314122e-01 8.27092132e-01 -2.68546399 0.41947769 973.00 -1.15013247e+00 -3.18832389e-01 1.19350693e+00 -2.87116962 0.62963574 973.25 -1.22238044e+00 -2.61229708e-01 1.24998196e+00 -2.93105390 0.69736746 973.50 -1.30821167e+00 -3.53715014e-01 1.35518710e+00 -2.87752614 0.79067009 973.75 -1.29801552e+00 -3.18083911e-01 1.33642121e+00 -2.90127443 0.75146873 974.00 -9.93706558e-01 -1.68833838e-01 1.00794722e+00 -2.97329666 0.62402981 974.25 -9.58635560e-01 -1.06213542e-01 9.64501660e-01 -3.03124614 0.64659392 974.50 -9.57273292e-01 6.24354152e-02 9.59307217e-01 3.07646276 0.62129178 974.75 -9.72075785e-01 4.28382543e-02 9.73019243e-01 3.09755231 0.63455278 975.00 -1.12673936e+00 -5.40356841e-02 1.12803432e+00 -3.09367180 0.64266528 975.25 -1.14369053e+00 -3.32751364e-02 1.14417449e+00 -3.11250633 0.71756649 975.50 -9.77363720e-01 1.09532660e-01 9.83482203e-01 3.02998883 0.67723015 975.75 -9.39967833e-01 1.33388943e-01 9.49385137e-01 3.00062589 0.57114004 976.00 -9.95234081e-01 1.66000528e-01 1.00898318e+00 2.97631866 0.57432439 976.25 -9.61056050e-01 1.28877486e-01 9.69658774e-01 3.00828805 0.51562290 976.50 -1.04565753e+00 2.31367863e-01 1.07094854e+00 2.92383566 0.43851009 976.75 -7.92104611e-01 4.01161323e-01 8.87896459e-01 2.67279843 0.36943166 977.00 -6.11998123e-01 6.20413610e-01 8.71467010e-01 2.34936613 0.47828137 977.25 -5.78793153e-01 6.25140187e-01 8.51940002e-01 2.31771714 0.43994052 977.50 -4.58402188e-01 5.84690652e-01 7.42964147e-01 2.23570974 0.34923899 977.75 -4.61683143e-01 6.21577974e-01 7.74280635e-01 2.20964759 0.34959513 978.00 -4.86803555e-01 6.10659130e-01 7.80949598e-01 2.24381370 0.33813223 978.25 -3.70258617e-01 7.72588639e-01 8.56729041e-01 2.01770184 0.35566338 978.50 -2.49280745e-01 9.58733817e-01 9.90611640e-01 1.82517411 0.38804982 978.75 -2.96837337e-01 1.00514172e+00 1.04805643e+00 1.85795301 0.35220523 979.00 -1.29780868e-01 1.18640867e+00 1.19348590e+00 1.67975279 0.43555328 979.25 -7.27386888e-02 1.29828290e+00 1.30031897e+00 1.62676465 0.33549197 979.50 -5.93364307e-02 1.56560686e+00 1.56673088e+00 1.60867815 0.29553094 979.75 1.79867765e-01 2.02126439e+00 2.02925162e+00 1.48204236 0.30794299 980.00 4.45978274e-01 2.56279710e+00 2.60131228e+00 1.39850158 0.41557223 980.25 3.52591327e-01 2.31829802e+00 2.34495764e+00 1.41986242 0.36955092 980.50 5.83935067e-01 1.92337119e+00 2.01005893e+00 1.27604026 0.25232549 980.75 7.67902892e-01 7.72628140e-01 1.08932506e+00 0.78846544 0.13920111 981.00 7.21732031e-01 4.94842757e-01 8.75080842e-01 0.60101795 0.12194128 981.25 5.78073913e-01 1.01682419e+00 1.16965844e+00 1.05385373 0.11721601 981.50 2.11333231e-01 1.03788998e+00 1.05918712e+00 1.36992422 0.07532523 981.75 1.16210104e-01 3.30393023e-01 3.50234690e-01 1.23257854 0.00994534 982.00 1.43582523e-01 -2.84826444e-01 3.18970287e-01 -1.10386986 0.00759965 982.25 1.41812205e-01 -4.58397931e-02 1.49036868e-01 -0.31264187 0.00126977 982.50 2.27057120e-01 1.79299926e-01 2.89315397e-01 0.66840961 0.00357523 982.75 1.82984740e-01 4.23278729e-02 1.87816569e-01 0.22732089 0.00234379 983.00 2.84008893e-01 1.19245360e-01 3.08026796e-01 0.39751313 0.00643024 983.25 -1.93897836e-02 1.11124401e-01 1.12803352e-01 1.74354437 0.00072164 983.50 8.18149508e-02 3.65545972e-01 3.74589835e-01 1.35060934 0.00637526 983.75 2.58687047e-01 1.17738882e+00 1.20547228e+00 1.35452026 0.08308946 984.00 -4.46403027e-02 1.13162257e+00 1.13250272e+00 1.61022393 0.06975662 984.25 -1.40227876e-01 8.22482419e-01 8.34350757e-01 1.73966605 0.03997341 984.50 -5.45300304e-01 5.00238439e-01 7.39993863e-01 2.39926702 0.03619854 984.75 -2.45662352e-01 -1.22996597e-01 2.74732877e-01 -2.67740650 0.00608402 985.00 1.93400359e-01 -1.45808497e-01 2.42206145e-01 -0.64600551 0.00494932 985.25 7.17865872e-01 -1.27510857e-01 7.29102481e-01 -0.17579143 0.04686032 985.50 7.78076457e-01 3.55088541e-02 7.78886289e-01 0.04560507 0.05431881 985.75 9.12185017e-01 4.60475568e-02 9.13346530e-01 0.05043769 0.08303862 986.00 9.55496107e-01 1.02090122e-01 9.60934547e-01 0.10644133 0.08913994 986.25 1.41064183e+00 2.21479746e-01 1.42792284e+00 0.15573500 0.15163167 986.50 1.45955356e+00 -1.10005445e-01 1.46369320e+00 -0.07522701 0.15823302 986.75 1.56129651e+00 -2.04013892e-01 1.57456930e+00 -0.12993336 0.22509790 987.00 1.86505009e+00 -1.02454100e-01 1.86786206e+00 -0.05487854 0.28295632 987.25 1.63312362e+00 4.10431680e-01 1.68390822e+00 0.24621778 0.14940671 987.50 1.67440819e+00 1.72755486e-01 1.68329654e+00 0.10281029 0.15986774 987.75 1.73762707e+00 3.04626492e-01 1.76412731e+00 0.17354816 0.29948560 988.00 1.80727276e+00 5.95353387e-01 1.90280858e+00 0.31822523 0.33740589 988.25 1.70736509e+00 3.30465093e-01 1.73905225e+00 0.19118860 0.21296827 988.50 1.66390060e+00 2.86728983e-01 1.68842492e+00 0.17064741 0.22821319 988.75 1.28590530e+00 7.77628882e-01 1.50275052e+00 0.54389210 0.31026046 989.00 1.03906787e+00 7.71505483e-01 1.29417261e+00 0.63868231 0.22720784 989.25 1.25609920e+00 7.22634580e-01 1.44913283e+00 0.52206013 0.23465381 989.50 1.08299616e+00 6.78616173e-01 1.27804561e+00 0.55975620 0.24078801 989.75 5.80237769e-01 3.65182233e-01 6.85590207e-01 0.56173313 0.12542284 990.00 4.76357556e-01 3.65973992e-01 6.00710816e-01 0.65509540 0.11362785 990.25 6.36700935e-01 5.37114024e-01 8.32994331e-01 0.70076046 0.23749896 990.50 3.44939014e-01 3.87399121e-01 5.18710905e-01 0.84331216 0.06962100 990.75 2.23401036e-02 2.54188482e-01 2.55168307e-01 1.48313363 0.01218031 991.00 3.33587428e-01 2.93952017e-01 4.44621593e-01 0.72232192 0.03312000 991.25 3.04472917e-01 -3.74683508e-02 3.06769677e-01 -0.12244411 0.01457076 991.50 -2.63543026e-01 8.15858803e-02 2.75882552e-01 2.84137633 0.01873734 991.75 -4.94704446e-02 -2.11184262e-01 2.16901170e-01 -1.80089980 0.01837768 992.00 -1.49294191e-01 -1.74702858e-01 2.29803925e-01 -2.27793214 0.02470804 992.25 -6.65804939e-02 -1.89771823e-01 2.01112672e-01 -1.90822373 0.01930387 992.50 3.13272608e-02 -2.13916670e-01 2.16198379e-01 -1.42538388 0.03227759 992.75 7.16224107e-03 -2.61137731e-01 2.61235932e-01 -1.54337614 0.05410597 993.00 -1.25965391e-01 -1.55638838e-01 2.00226691e-01 -2.25120904 0.04979320 993.25 -8.81709524e-02 -2.43693736e-01 2.59153919e-01 -1.91795376 0.10667999 993.50 7.23754285e-02 -1.56041014e-01 1.72008723e-01 -1.13650675 0.08906336 993.75 8.04437999e-02 -1.50182612e-01 1.70370250e-01 -1.07904495 0.07839745 994.00 1.95138587e-01 -2.03804771e-01 2.82162104e-01 -0.80711759 0.20859853 994.25 1.55780042e-01 -2.07994229e-01 2.59863466e-01 -0.92795904 0.22299736 994.50 1.80533265e-02 -2.85221115e-01 2.85791895e-01 -1.50758476 0.44264216 994.75 -3.94356309e-03 -2.99934989e-01 2.99960913e-01 -1.58394363 0.51185870 995.00 4.06796597e-02 -2.58668952e-01 2.61848165e-01 -1.41480860 0.38157563 995.25 3.02094676e-02 -2.77041149e-01 2.78683351e-01 -1.46218221 0.38614230 995.50 -6.45735504e-02 -2.95035652e-01 3.02019501e-01 -1.78626562 0.34078708 995.75 -1.04792209e-01 -2.20924245e-01 2.44517748e-01 -2.01370234 0.25974201 996.00 -3.71656502e-02 -2.02094574e-01 2.05483582e-01 -1.75266648 0.17789176 996.25 -5.03479982e-02 -1.42193510e-01 1.50844009e-01 -1.91110201 0.07403941 996.50 -5.92307147e-02 -2.11050482e-01 2.19204433e-01 -1.84440502 0.11840426 996.75 7.61683801e-03 -1.51703709e-01 1.51894804e-01 -1.52062981 0.08001908 997.00 1.63190259e-02 -1.30028590e-01 1.31048636e-01 -1.44594574 0.08907660 997.25 -3.83347857e-02 -1.76553357e-01 1.80667218e-01 -1.78460616 0.14619708 997.50 -3.21767867e-02 -2.23117657e-01 2.25425896e-01 -1.71402327 0.23796820 997.75 -1.07462161e-01 -2.71693173e-01 2.92173401e-01 -1.94744129 0.30859871 998.00 -1.90465006e-01 -3.50139467e-01 3.98590724e-01 -2.06899740 0.44896606 998.25 -2.45840461e-01 -3.19439796e-01 4.03087231e-01 -2.22672308 0.36229146 998.50 -3.86582863e-01 -2.99234301e-01 4.88863454e-01 -2.48287664 0.40350659 998.75 -5.46818822e-01 -2.13749199e-01 5.87111186e-01 -2.76895925 0.36778077 999.00 -3.94126717e-01 -7.94882311e-03 3.94206866e-01 -3.12142720 0.19388345 999.25 -3.54018219e-01 1.54718515e-01 3.86350512e-01 2.72957219 0.22623624 999.50 -4.05052549e-01 1.17790968e-01 4.21832052e-01 2.85859361 0.27668624 999.75 -3.77371964e-01 6.85904250e-02 3.83554750e-01 2.96179728 0.20220392 1000.00 -3.58545022e-01 0.00000000e+00 3.58545022e-01 3.14159265 0.15805347