========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : WI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0055 Injection acquisition : SIG0056 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -4.35278722e-02 0.00000000e+00 4.35278722e-02 3.14159265 0.07658807 0.25 -4.21086142e-02 2.08970060e-02 4.70087252e-02 2.68093799 0.08683828 0.50 -2.12038911e-02 1.46599242e-02 2.57782540e-02 2.53667609 0.01830930 0.75 -1.98621990e-02 8.31016075e-03 2.15305764e-02 2.74533337 0.01362773 1.00 -2.81015646e-02 6.98351212e-03 2.89563011e-02 2.89801709 0.02440951 1.25 -2.59037012e-02 4.16185469e-03 2.62359062e-02 2.98228768 0.02034624 1.50 -2.95425266e-02 1.88283872e-03 2.96024655e-02 3.07794557 0.02495543 1.75 -2.84212078e-02 3.16408694e-03 2.85967918e-02 3.03072082 0.02421177 2.00 -3.06439254e-02 7.41796944e-03 3.15289777e-02 2.90409150 0.02972655 2.25 -2.71749329e-02 4.37859649e-03 2.75254262e-02 2.98183939 0.02276003 2.50 -2.86271391e-02 4.50025645e-03 2.89787060e-02 2.98566629 0.02432967 2.75 -2.69440387e-02 3.02807822e-03 2.71136585e-02 3.02967827 0.02130918 3.00 -2.50994386e-02 3.04423710e-03 2.52833779e-02 3.02089513 0.01816538 3.25 -2.61235091e-02 1.36346381e-03 2.61590665e-02 3.08944699 0.01945436 3.50 -2.48304662e-02 3.19872662e-03 2.50356527e-02 3.01347560 0.01748619 3.75 -2.62150375e-02 -9.55074004e-04 2.62324295e-02 -3.10517646 0.01907444 4.00 -2.69286501e-02 -5.24636845e-03 2.74349518e-02 -2.94917818 0.02043908 4.25 -2.81848028e-02 -3.75698115e-04 2.81873067e-02 -3.12826363 0.02244991 4.50 -2.53948231e-02 1.77517242e-03 2.54567924e-02 3.07180325 0.01842953 4.75 -2.45275580e-02 6.20398446e-04 2.45354029e-02 3.11630411 0.01601341 5.00 -2.57162114e-02 1.63981847e-03 2.57684407e-02 3.07791293 0.01768695 5.25 -2.86444537e-02 3.58077225e-03 2.88673978e-02 3.01723025 0.02125286 5.50 -3.02047783e-02 -2.99322943e-04 3.02062614e-02 -3.13168319 0.02289853 5.75 -2.84656037e-02 -1.09013249e-03 2.84864701e-02 -3.10331488 0.02060986 6.00 -2.62961454e-02 -2.41890540e-03 2.64071651e-02 -3.04986373 0.01745317 6.25 -2.46563988e-02 -8.31226872e-04 2.46704062e-02 -3.10789300 0.01477140 6.50 -2.81983443e-02 4.37796587e-04 2.82017426e-02 3.12606829 0.01926735 6.75 -2.79398519e-02 3.66694257e-03 2.81794569e-02 3.01109436 0.01833434 7.00 -2.71201989e-02 -1.07910197e-03 2.71416590e-02 -3.10182403 0.01703454 7.25 -3.13407929e-02 -2.45139625e-03 3.14365176e-02 -3.06353415 0.02042472 7.50 -2.86479141e-02 1.98388038e-03 2.87165243e-02 3.07245261 0.01777348 7.75 -2.34516358e-02 -3.23963356e-03 2.36743415e-02 -3.00432039 0.01241294 8.00 -3.00000400e-02 -5.18015361e-03 3.04439878e-02 -2.97060713 0.01991262 8.25 -2.92297603e-02 -7.56419569e-03 3.01926471e-02 -2.88836389 0.01904800 8.50 -2.37536661e-02 -5.97998986e-03 2.44948348e-02 -2.89496744 0.01227552 8.75 -2.85933542e-02 -6.06249260e-03 2.92289876e-02 -2.93266223 0.01705068 9.00 -2.77216724e-02 -1.47853639e-03 2.77610732e-02 -3.08830810 0.01541734 9.25 -3.27013948e-02 7.83583963e-03 3.36270963e-02 2.90640899 0.02067990 9.50 -3.35364577e-02 1.33405560e-03 3.35629811e-02 3.10183435 0.02152261 9.75 -3.09967127e-02 -7.32667317e-03 3.18508452e-02 -2.90948339 0.01882413 10.00 -2.63410929e-02 -6.25381498e-03 2.70732964e-02 -2.90849172 0.01371443 10.25 -2.50082418e-02 -5.87807030e-03 2.56897619e-02 -2.91073774 0.01135880 10.50 -2.88535949e-02 -3.07774986e-03 2.90172790e-02 -3.03532666 0.01486498 10.75 -2.52490679e-02 -2.63238803e-03 2.53859192e-02 -3.03771111 0.01128506 11.00 -3.06263570e-02 -9.21846464e-03 3.19836495e-02 -2.84922074 0.01771127 11.25 -3.88948960e-02 -1.42813376e-02 4.14339177e-02 -2.78969748 0.02830906 11.50 -2.95615125e-02 -5.07795853e-03 2.99944776e-02 -2.97147688 0.01443180 11.75 -2.21491426e-02 4.79390403e-04 2.21543299e-02 3.11995229 0.00735716 12.00 -2.99175513e-02 7.34078443e-03 3.08049833e-02 2.90097905 0.01404403 12.25 -3.39729473e-02 1.49898371e-02 3.71329552e-02 2.72605690 0.02053990 12.50 -2.76747102e-02 -3.33604554e-03 2.78750566e-02 -3.02162658 0.01218099 12.75 -2.67008566e-02 -1.52010974e-02 3.07247312e-02 -2.62404415 0.01420547 13.00 -2.92430851e-02 -1.73000895e-03 2.92942137e-02 -3.08250193 0.01272279 13.25 -2.96176144e-02 -8.06796873e-03 3.06968273e-02 -2.87564114 0.01306990 13.50 -4.32159273e-02 -9.90420161e-03 4.43363235e-02 -2.91630375 0.02591258 13.75 -4.51119673e-02 1.24349955e-03 4.51291024e-02 3.11403489 0.02461314 14.00 -3.03804985e-02 2.35656012e-03 3.04717585e-02 3.06417948 0.01037006 14.25 -3.71595193e-02 -4.32782779e-03 3.74106932e-02 -3.02564881 0.01519254 14.50 -3.70752463e-02 -2.92389026e-03 3.71903619e-02 -3.06289187 0.01661086 14.75 -3.29438693e-02 -9.51314717e-03 3.42899182e-02 -2.86047170 0.01307981 15.00 -3.00500209e-02 6.03497838e-03 3.06500362e-02 2.94339810 0.00993803 15.25 -3.51907318e-02 7.74554898e-04 3.51992548e-02 3.11958601 0.01189942 15.50 -2.53291942e-02 -5.80379836e-03 2.59856143e-02 -2.91634621 0.00764179 15.75 -2.07469279e-02 -6.81590931e-03 2.18378487e-02 -2.82417474 0.00518802 16.00 -3.85463671e-02 1.86021133e-02 4.28002458e-02 2.69196934 0.02063670 16.25 -3.67347224e-02 1.70175666e-02 4.04850269e-02 2.70777019 0.01826258 16.50 -3.60861233e-02 -4.63655171e-03 3.63827694e-02 -3.01380705 0.01308935 16.75 -4.02545636e-02 -6.21670878e-03 4.07317733e-02 -2.98836826 0.01629944 17.00 -4.13692572e-02 4.04620026e-03 4.15666595e-02 3.04409582 0.01527824 17.25 -3.72949837e-02 -7.24918010e-03 3.79929785e-02 -2.94961239 0.01343206 17.50 -4.70800650e-02 -1.67131942e-02 4.99586166e-02 -2.80047477 0.02570939 17.75 -4.22356336e-02 -7.68726288e-03 4.29295092e-02 -2.96155451 0.02002910 18.00 -2.46949135e-02 -1.08513049e-03 2.47187431e-02 -3.09767945 0.00559403 18.25 -2.92408756e-02 1.12938388e-03 2.92626779e-02 3.10298838 0.00828015 18.50 -3.09537146e-02 1.53460438e-02 3.45490016e-02 2.68133164 0.01033847 18.75 -3.04488604e-02 5.17268719e-04 3.04532538e-02 3.12460617 0.00825841 19.00 -3.24931185e-02 -2.55529846e-02 4.13371234e-02 -2.47519205 0.01641175 19.25 -3.42629082e-02 -6.12677743e-03 3.48063828e-02 -2.96464619 0.01171460 19.50 -3.36632658e-02 7.03184034e-03 3.43898567e-02 2.93566607 0.01029111 19.75 -3.52109518e-02 -1.58513516e-04 3.52113086e-02 -3.13709086 0.01038170 20.00 -3.74221803e-02 -3.51524394e-03 3.75869195e-02 -3.04793271 0.01152128 20.25 -3.22607551e-02 -1.52251773e-02 3.56729918e-02 -2.70064304 0.01080987 20.50 -2.15335226e-02 -4.58929534e-02 5.06937449e-02 -2.00951156 0.02197820 20.75 -3.89660485e-02 -2.37651428e-02 4.56413732e-02 -2.59393020 0.01738907 21.00 -5.27835732e-02 -1.87280231e-02 5.60075392e-02 -2.80064116 0.02411682 21.25 -4.03509133e-02 -2.36756656e-02 4.67839005e-02 -2.61097706 0.01646472 21.50 -6.19727133e-02 -2.10960004e-02 6.54649404e-02 -2.81348857 0.02923523 21.75 -3.71696611e-02 -2.11872487e-02 4.27841468e-02 -2.62351312 0.01273284 22.00 -3.92615217e-02 -7.88606085e-03 4.00456870e-02 -2.94337051 0.00999054 22.25 -4.72361231e-02 1.34268170e-02 4.91073390e-02 2.86464829 0.01545630 22.50 -5.95132728e-02 3.09582414e-02 6.70838457e-02 2.66192339 0.02578073 22.75 -4.00901235e-02 -1.30885860e-03 4.01114836e-02 -3.10895634 0.01061604 23.00 -5.67652618e-02 -1.59648949e-02 5.89675573e-02 -2.86743067 0.01985558 23.25 -6.99540096e-02 -1.89493925e-02 7.24751194e-02 -2.87705746 0.03580265 23.50 -6.58843118e-02 -1.33585371e-02 6.72249437e-02 -2.94154708 0.03114412 23.75 -7.29128055e-02 -2.58113513e-02 7.73466422e-02 -2.80135615 0.04327349 24.00 -7.88137157e-02 -9.54711507e-03 7.93898557e-02 -3.02104479 0.04605137 24.25 -6.24532514e-02 -1.93589203e-02 6.53848332e-02 -2.84101018 0.02695202 24.50 -6.02394133e-02 -2.47868775e-02 6.51396670e-02 -2.75123526 0.02554858 24.75 -6.38744672e-02 -2.74008502e-02 6.95036269e-02 -2.73635599 0.03134154 25.00 -5.70886042e-02 -3.19451995e-02 6.54186862e-02 -2.63143001 0.02618577 25.25 -4.76234397e-02 -4.66100005e-02 6.66369579e-02 -2.36694864 0.02770339 25.50 -5.41141467e-02 -4.15935904e-02 6.82522354e-02 -2.48627650 0.02988743 25.75 -5.19037870e-02 -3.82055372e-02 6.44489424e-02 -2.50705756 0.02641390 26.00 -4.97196998e-02 -3.94281643e-02 6.34557222e-02 -2.47112914 0.02579867 26.25 -4.99966393e-02 -4.51888297e-02 6.73920935e-02 -2.40666151 0.02459434 26.50 -4.82757622e-02 -3.46748182e-02 5.94381379e-02 -2.51871281 0.01857624 26.75 -5.20134684e-02 -2.37355194e-02 5.71732086e-02 -2.71348379 0.01813876 27.00 -6.12224745e-02 -2.92375760e-02 6.78456133e-02 -2.69605539 0.02449147 27.25 -2.31652175e-02 -9.82336943e-03 2.51619929e-02 -2.74052112 0.00352596 27.50 -3.21176361e-02 -1.63213466e-02 3.60267803e-02 -2.67142727 0.00705113 27.75 -4.49921969e-02 -5.97152770e-02 7.47677209e-02 -2.21649881 0.02643690 28.00 -3.05692237e-02 -4.50520068e-02 5.44441067e-02 -2.16696840 0.01426036 28.25 -1.74577586e-02 -2.45838252e-02 3.01519120e-02 -2.18828991 0.00459840 28.50 -2.12422372e-02 -2.54788086e-02 3.31723126e-02 -2.26576380 0.00530206 28.75 -9.79975915e-03 -2.42653309e-03 1.00957091e-02 -2.89886325 0.00039048 29.00 -4.35416127e-03 -2.70819200e-03 5.12767240e-03 -2.58516950 0.00011496 29.25 -1.75760319e-02 -6.40423825e-02 6.64104182e-02 -1.83864533 0.01716316 29.50 -2.05848264e-02 -6.08004609e-02 6.41905844e-02 -1.89724676 0.01559131 29.75 -1.40227948e-02 -3.77810830e-02 4.02994913e-02 -1.92619543 0.00594706 30.00 -1.10090676e-02 -2.63467613e-02 2.85543587e-02 -1.96659768 0.00274219 30.25 2.04285183e-02 -6.81408336e-02 7.11371743e-02 -1.27952442 0.01378183 30.50 -1.66708037e-02 -5.32732037e-02 5.58206945e-02 -1.87407323 0.01048010 30.75 -2.99278854e-02 -8.44309853e-03 3.10960486e-02 -2.86662400 0.00282994 31.00 -2.50834758e-02 -2.53275403e-02 3.56463891e-02 -2.35135304 0.00356271 31.25 -1.42695164e-02 -2.28749865e-02 2.69607883e-02 -2.12853540 0.00160341 31.50 -3.46347481e-02 -5.73851767e-02 6.70270415e-02 -2.11382107 0.01394616 31.75 -5.16507199e-02 -7.90254210e-02 9.44077011e-02 -2.14969552 0.03163144 32.00 2.01421136e-02 -8.15804991e-02 8.40302480e-02 -1.32873872 0.02281182 32.25 5.43631524e-02 -1.28287093e-01 1.39330293e-01 -1.16997503 0.05041640 32.50 -1.45461856e-02 -6.94261593e-02 7.09336529e-02 -1.77732898 0.01181535 32.75 -2.69547780e-02 -5.65984315e-02 6.26892535e-02 -2.01526082 0.00786638 33.00 -3.31447242e-02 -7.03024640e-02 7.77239293e-02 -2.01135150 0.01639886 33.25 -3.21250245e-02 -1.41054052e-01 1.44666039e-01 -1.79472647 0.05013344 33.50 -5.84117658e-02 -6.81717748e-02 8.97737449e-02 -2.27924344 0.02171842 33.75 -2.96437255e-02 -1.07528103e-04 2.96439205e-02 -3.13796532 0.00229191 34.00 4.26507467e-02 -2.30307164e-02 4.84716422e-02 -0.49512080 0.00775813 34.25 5.21511424e-02 -1.42013353e-02 5.40501579e-02 -0.26586465 0.00796755 34.50 -2.85728391e-03 -1.09060231e-01 1.09097654e-01 -1.59698947 0.02501543 34.75 3.35347138e-02 -1.73218069e-01 1.76434340e-01 -1.37956381 0.06861015 35.00 3.98556838e-02 -6.21392488e-02 7.38225018e-02 -1.00049549 0.00914730 35.25 8.27631169e-02 -4.14021310e-02 9.25411799e-02 -0.46384645 0.01455734 35.50 9.49786708e-02 1.96114100e-03 9.49989157e-02 0.02064529 0.01900522 35.75 7.84809089e-02 5.91737993e-02 9.82893259e-02 0.64604965 0.02145818 36.00 -7.33345201e-02 6.62007559e-02 9.87952019e-02 2.40727518 0.01825929 36.25 -1.84250193e-01 2.55881522e-01 3.15314901e-01 2.19485926 0.11093370 36.50 -3.86844211e-01 7.24797924e-01 8.21571954e-01 2.06106008 0.36845978 36.75 -2.84528722e-01 4.68694554e-01 5.48298440e-01 2.11639553 0.20308534 37.00 -1.37107197e-01 4.02761972e-03 1.37166341e-01 3.11222540 0.02467225 37.25 -8.92161686e-02 -3.50712429e-02 9.58619676e-02 -2.76704510 0.01468104 37.50 -1.21121164e-01 5.30042798e-03 1.21237085e-01 3.09785919 0.03152902 37.75 -9.21063021e-02 -2.06062221e-02 9.43831938e-02 -2.92149480 0.01791481 38.00 -1.25674488e-01 -1.52063809e-01 1.97275135e-01 -2.26146382 0.06204808 38.25 -9.78440049e-02 -1.30668378e-01 1.63241154e-01 -2.21352666 0.04388096 38.50 1.97423502e-02 -5.14775522e-02 5.51334633e-02 -1.20458250 0.00579127 38.75 -1.04124357e-02 -8.20298938e-02 8.26881025e-02 -1.69705575 0.01310136 39.00 -1.33987710e-01 -1.27938193e-01 1.85258975e-01 -2.37928668 0.05443578 39.25 -8.25371750e-02 -8.69246828e-02 1.19867784e-01 -2.33030945 0.02727812 39.50 -6.84694086e-02 -1.84045682e-01 1.96369227e-01 -1.92695534 0.05024530 39.75 -3.98131286e-02 -8.16380395e-02 9.08287108e-02 -2.02453836 0.01443730 40.00 8.05628158e-03 -5.48062834e-02 5.53952378e-02 -1.42484597 0.00768609 40.25 -6.97972649e-03 -7.42735150e-02 7.46007480e-02 -1.66449445 0.01276514 40.50 2.21720047e-02 -9.68944382e-02 9.93988428e-02 -1.34584287 0.01489139 40.75 -2.41495661e-02 -2.47986625e-02 3.46146675e-02 -2.34293439 0.00228360 41.00 -9.18431139e-02 -4.50680505e-03 9.19536234e-02 -3.09256129 0.01779932 41.25 -1.02355658e-01 5.58194737e-03 1.02507751e-01 3.08711180 0.02580221 41.50 -7.75889460e-02 -2.70154100e-02 8.21576346e-02 -2.80653449 0.01725114 41.75 -8.66534542e-02 -5.37345267e-02 1.01961858e-01 -2.58651870 0.02461282 42.00 -1.00103382e-01 -1.05784181e-01 1.45639898e-01 -2.32860973 0.05102146 42.25 -7.04081626e-02 -1.04976682e-01 1.26401792e-01 -2.16158803 0.04137801 42.50 -7.50432605e-02 -1.13596974e-01 1.36146111e-01 -2.15459390 0.05345958 42.75 -1.81127738e-02 -7.97148019e-02 8.17466955e-02 -1.79422251 0.01833171 43.00 1.79523545e-02 -7.57010154e-02 7.78005833e-02 -1.33794963 0.01722373 43.25 1.36882658e-02 -1.09198825e-01 1.10053405e-01 -1.44609499 0.02787280 43.50 3.79686221e-03 -1.68530677e-01 1.68573442e-01 -1.54827093 0.06304225 43.75 -4.51907337e-02 -7.51758567e-02 8.77132364e-02 -2.11204894 0.02191722 44.00 -2.86361201e-02 -8.13097496e-02 8.62050042e-02 -1.90941687 0.02712905 44.25 -8.77952669e-03 -3.61083680e-02 3.71603866e-02 -1.80931178 0.00411524 44.50 2.95760759e-02 -1.97954371e-02 3.55893747e-02 -0.58982742 0.00530658 44.75 1.05327197e-01 -5.04263748e-02 1.16776015e-01 -0.44651111 0.07548302 45.00 1.64524652e-01 -2.61160726e-02 1.66584544e-01 -0.15742309 0.13157317 45.25 1.47274437e-01 -9.17239516e-02 1.73502286e-01 -0.55702274 0.08854891 45.50 1.21789602e-01 -1.00891410e-01 1.58151142e-01 -0.69182412 0.06094648 45.75 8.06644866e-02 -1.18628443e-01 1.43455453e-01 -0.97363612 0.05350847 46.00 1.29946952e-01 -7.79814314e-02 1.51549708e-01 -0.54049453 0.06461013 46.25 2.46946841e-01 6.24060937e-02 2.54710155e-01 0.24752822 0.20658762 46.50 2.28564355e-01 1.46956033e-01 2.71731007e-01 0.57140498 0.20804773 46.75 9.39717799e-02 2.16333970e-01 2.35862421e-01 1.16100519 0.11138627 47.00 2.86250441e-02 1.57490542e-01 1.60070809e-01 1.39100183 0.04234967 47.25 -4.44778999e-02 6.88133644e-02 8.19363332e-02 2.14460527 0.00739826 47.50 -5.72424099e-02 -3.12432624e-02 6.52137634e-02 -2.64197495 0.00435686 47.75 -7.84391879e-02 -7.01210291e-02 1.05212475e-01 -2.41212792 0.00809010 48.00 -1.07474289e-01 -1.53488068e-01 1.87374785e-01 -2.18166501 0.02114639 48.25 -8.85550237e-02 -4.04872655e-01 4.14444036e-01 -1.78612841 0.07057421 48.50 -2.49729356e-01 -4.37469594e-01 5.03730480e-01 -2.08950590 0.13150666 48.75 -6.60636018e-02 -2.06275971e-01 2.16596805e-01 -1.88074240 0.04504982 49.00 -9.21793562e-02 -2.43233887e-01 2.60114893e-01 -1.93304663 0.06296490 49.25 -5.62736506e-01 -7.95899427e-01 9.74745235e-01 -2.18623468 0.43915713 49.50 -6.32696068e-01 -9.49304063e-01 1.14082537e+00 -2.15867253 0.54499169 49.75 -7.39515950e-01 -1.04285535e+00 1.27844872e+00 -2.18762097 0.48443695 50.00 -1.27389950e+00 -7.74224375e-01 1.49071906e+00 -2.59548725 0.21634437 50.25 -1.87560557e+00 1.14902664e+00 2.19958143e+00 2.59194804 0.20892570 50.50 -8.16485143e-01 1.25879414e+00 1.50040351e+00 2.14620422 0.22935167 50.75 -1.51657206e-01 1.06802770e+00 1.07874143e+00 1.71185078 0.33907629 51.00 -5.56298387e-03 6.02305325e-01 6.02331015e-01 1.58003222 0.17462467 51.25 2.07645209e-01 4.02071050e-01 4.52523659e-01 1.09408410 0.13016464 51.50 1.63346932e-01 3.25561527e-01 3.64242403e-01 1.10575844 0.09217114 51.75 9.09469548e-02 5.29654836e-01 5.37406358e-01 1.40074481 0.16902229 52.00 2.06553831e-01 3.95594655e-01 4.46273029e-01 1.08959790 0.15244007 52.25 4.64298332e-01 1.72922222e-01 4.95454373e-01 0.35652242 0.15280508 52.50 4.67872207e-01 1.47283441e-01 4.90506691e-01 0.30497356 0.23788475 52.75 5.64762001e-01 2.15107808e-01 6.04340539e-01 0.36391769 0.47698004 53.00 3.66631210e-01 2.21010196e-01 4.28093390e-01 0.54248559 0.32362810 53.25 1.85220349e-01 1.85290802e-01 2.61990952e-01 0.78558831 0.14355394 53.50 5.66755182e-02 1.36743556e-01 1.48023358e-01 1.17788202 0.02902397 53.75 6.71570332e-02 -1.43489361e-02 6.86728409e-02 -0.21049735 0.00631821 54.00 2.49365008e-01 -3.37343792e-02 2.51636475e-01 -0.13446481 0.07262695 54.25 4.45541805e-01 1.12180776e-02 4.45683010e-01 0.02517319 0.26196956 54.50 4.01340492e-01 1.35568444e-01 4.23618925e-01 0.32575537 0.40967575 54.75 3.54681833e-01 2.22660898e-01 4.18780465e-01 0.56059337 0.45895258 55.00 2.99872097e-01 1.38857921e-01 3.30461491e-01 0.43365905 0.29918634 55.25 3.55070272e-01 1.46771586e-01 3.84209314e-01 0.39196967 0.37330980 55.50 3.86045079e-02 2.36676410e-01 2.39804151e-01 1.40910927 0.13076257 55.75 -1.30279530e-01 3.37424651e-01 3.61701743e-01 1.93926249 0.23684053 56.00 -9.20561130e-02 5.23539437e-01 5.31571134e-01 1.74485124 0.28833630 56.25 -2.50710548e-02 6.02923320e-01 6.03444354e-01 1.61235488 0.30176033 56.50 -7.05803663e-02 4.22606144e-01 4.28459497e-01 1.73628114 0.10410443 56.75 2.24206327e-02 5.30019022e-01 5.30493024e-01 1.52851997 0.13561720 57.00 2.77494862e-01 5.91640012e-01 6.53483973e-01 1.13223308 0.27954725 57.25 2.84880494e-01 5.41160863e-01 6.11565185e-01 1.08623304 0.29194667 57.50 4.77507774e-02 4.17807539e-01 4.20527379e-01 1.45700114 0.12793649 57.75 6.61408585e-02 4.43064304e-01 4.47973873e-01 1.42261013 0.12740216 58.00 2.09252166e-01 6.53823131e-01 6.86491919e-01 1.26105348 0.26077599 58.25 2.12436790e-01 8.40268996e-01 8.66707202e-01 1.32316533 0.36451104 58.50 -7.31658538e-02 9.87411309e-01 9.90118344e-01 1.64475982 0.58413649 58.75 -8.43803955e-02 9.97252683e-01 1.00081615e+00 1.65520812 0.60255384 59.00 -3.59787216e-01 8.54274404e-01 9.26947463e-01 1.96941097 0.50601953 59.25 -5.66364179e-01 9.97334673e-01 1.14692843e+00 2.08726158 0.46029409 59.50 -1.26798724e+00 1.43348771e+00 1.91381260e+00 2.29500796 0.47834364 59.75 -7.61657101e-01 1.31829363e+00 1.52250439e+00 2.09470222 0.27912118 60.00 5.20569263e-02 1.67210249e+00 1.67291263e+00 1.53967376 0.32767029 60.25 -4.07159930e-02 1.46784171e+00 1.46840631e+00 1.59852790 0.25346190 60.50 -2.65780157e-01 1.08469332e+00 1.11678051e+00 1.81108995 0.13736915 60.75 -2.54982629e-02 4.08729240e-01 4.09523813e-01 1.63309983 0.03609825 61.00 5.85274393e-01 1.55630478e-01 6.05612880e-01 0.25989609 0.09040743 61.25 4.37729510e-01 3.22427500e-01 5.43660387e-01 0.63486380 0.06153121 61.50 6.26579870e-01 4.32837621e-01 7.61544968e-01 0.60452069 0.09788823 61.75 5.56935370e-01 3.96298799e-01 6.83542057e-01 0.61844929 0.09017164 62.00 7.63833254e-01 4.03528901e-01 8.63873147e-01 0.48602615 0.14859086 62.25 7.38143190e-01 4.59931619e-01 8.69708263e-01 0.55722658 0.17134407 62.50 1.01150242e+00 5.18594841e-01 1.13669598e+00 0.47375400 0.26401210 62.75 9.63803814e-01 5.31393654e-01 1.10058939e+00 0.50387942 0.25473864 63.00 1.29623741e+00 5.72804323e-01 1.41715779e+00 0.41609565 0.35456695 63.25 1.43854825e+00 5.89028480e-01 1.55446956e+00 0.38863516 0.41466337 63.50 1.86650288e+00 3.91957722e-01 1.90721364e+00 0.20698815 0.52794672 63.75 1.78219993e+00 5.03504043e-01 1.85195921e+00 0.27534237 0.54846133 64.00 1.88448035e+00 6.18419847e-01 1.98335808e+00 0.31709155 0.64284007 64.25 1.48953870e+00 4.84207784e-01 1.56626393e+00 0.31429730 0.46462837 64.50 1.50886617e+00 6.29257850e-01 1.63482187e+00 0.39510935 0.49177672 64.75 1.28583292e+00 4.88762969e-01 1.37559280e+00 0.36324653 0.36456530 65.00 1.26462299e+00 3.59499394e-01 1.31472854e+00 0.27696754 0.34967296 65.25 7.16893980e-01 2.68014564e-01 7.65355333e-01 0.35776666 0.13968388 65.50 9.87137876e-01 4.89814177e-01 1.10197963e+00 0.46060003 0.24739676 65.75 1.13165516e+00 4.69611243e-01 1.22522574e+00 0.39335083 0.28593611 66.00 1.30126323e+00 6.27475323e-01 1.44464919e+00 0.44931034 0.34084810 66.25 1.28455608e+00 6.45639061e-01 1.43768360e+00 0.46573860 0.30293739 66.50 1.50006689e+00 8.23715094e-01 1.71134661e+00 0.50216650 0.38146239 66.75 1.69346126e+00 8.59899226e-01 1.89927294e+00 0.46984915 0.33560649 67.00 1.90328680e+00 4.70711844e-01 1.96063007e+00 0.24245024 0.29905428 67.25 2.16645815e+00 -1.91618218e-01 2.17491574e+00 -0.08821812 0.29899980 67.50 2.50524744e+00 -4.69993850e-03 2.50525185e+00 -0.00187604 0.38292120 67.75 3.32637871e+00 -2.41794700e-02 3.32646659e+00 -0.00726888 0.57916143 68.00 3.87096558e+00 -1.81108043e-01 3.87519995e+00 -0.04675218 0.61677352 68.25 6.14180832e+00 -6.80936493e-01 6.17944042e+00 -0.11041811 0.70234703 68.50 7.76671565e+00 -1.77722887e+00 7.96745973e+00 -0.22495338 0.67161408 68.75 4.43102918e+00 -5.03903896e+00 6.71013660e+00 -0.84951348 0.36105009 69.00 -6.76450574e-01 -2.44291421e+00 2.53484027e+00 -1.84093099 0.10375371 69.25 -2.27121258e+00 -3.84291835e-01 2.30349448e+00 -2.97397899 0.44009743 69.50 -1.48252773e+00 -1.83697865e-01 1.49386525e+00 -3.01831246 0.42551683 69.75 -3.99102246e-01 6.78569923e-02 4.04829809e-01 2.97317909 0.15001145 70.00 -2.67907929e-01 1.90308726e-02 2.68583008e-01 3.07067665 0.11893273 70.25 -1.04209990e-01 -2.42509615e-02 1.06994538e-01 -2.91294963 0.04703918 70.50 -3.30069982e-02 1.05827569e-02 3.46620350e-02 2.83132594 0.00809530 70.75 3.69543210e-02 -1.61574032e-02 4.03321648e-02 -0.41218074 0.01938723 71.00 4.94498076e-02 -2.36910204e-02 5.48319972e-02 -0.44678196 0.03233390 71.25 -8.61234584e-03 2.07952836e-02 2.25081390e-02 1.96344030 0.00629898 71.50 -2.15350810e-02 8.93310996e-02 9.18901793e-02 1.80735313 0.06112177 71.75 5.00710008e-02 2.41500328e-01 2.46636399e-01 1.36635980 0.25496872 72.00 1.53224515e-01 3.38870312e-01 3.71901654e-01 1.14614535 0.35803826 72.25 3.06069325e-01 3.34604205e-01 4.53473710e-01 0.82990763 0.52371751 72.50 4.12787457e-01 2.66238335e-01 4.91198875e-01 0.57283587 0.63364723 72.75 4.55996230e-01 2.24536831e-01 5.08280780e-01 0.45755671 0.78874008 73.00 4.14740649e-01 1.94058956e-01 4.57895932e-01 0.43764303 0.76281781 73.25 3.72528840e-01 1.65713927e-01 4.07723978e-01 0.41855055 0.81036287 73.50 3.53516254e-01 1.51043120e-01 3.84431744e-01 0.40378277 0.81938041 73.75 3.28558826e-01 1.35271855e-01 3.55315883e-01 0.39056261 0.86891636 74.00 2.95962293e-01 1.16299910e-01 3.17992685e-01 0.37441852 0.81669051 74.25 2.62034564e-01 1.14951808e-01 2.86139880e-01 0.41340839 0.82924900 74.50 2.04243266e-01 1.22946567e-01 2.38392890e-01 0.54186047 0.72689692 74.75 1.83322615e-01 1.39776116e-01 2.30531004e-01 0.65142778 0.78741623 75.00 1.65924401e-01 1.30500680e-01 2.11095558e-01 0.66645910 0.60644749 75.25 1.40503948e-01 1.02197383e-01 1.73740221e-01 0.62885538 0.45841309 75.50 1.96068312e-02 1.35648626e-01 1.37058300e-01 1.42724917 0.20887036 75.75 -5.08764825e-02 1.66086481e-01 1.73704161e-01 1.86804595 0.31874240 76.00 -6.97970541e-02 1.74962005e-01 1.88370199e-01 1.95037729 0.25680690 76.25 -1.38324146e-01 2.01309654e-01 2.44252219e-01 2.17282645 0.37710051 76.50 -2.71263878e-01 2.11574424e-01 3.44017192e-01 2.47919249 0.37078334 76.75 -3.98527297e-01 3.27532415e-01 5.15850259e-01 2.45366568 0.39349223 77.00 3.04344899e-01 5.18662877e-01 6.01362618e-01 1.04014854 0.33451859 77.25 4.44343794e-01 3.15821840e-01 5.45146624e-01 0.61791106 0.56507819 77.50 2.32284503e-01 2.06396241e-01 3.10733806e-01 0.72645263 0.56482651 77.75 9.81289707e-02 2.37475405e-01 2.56951091e-01 1.17894782 0.47902148 78.00 -1.60897081e-01 5.23202682e-01 5.47383702e-01 1.86914097 0.69338679 78.25 -1.05222969e-01 7.30786486e-01 7.38322938e-01 1.71379941 0.77401918 78.50 2.36807208e-01 6.97022311e-01 7.36150634e-01 1.24328981 0.81479791 78.75 2.46337157e-01 5.62754533e-01 6.14308277e-01 1.15818895 0.80777469 79.00 2.45905060e-01 3.59538224e-01 4.35588146e-01 0.97092569 0.77306359 79.25 2.02686769e-01 3.15036840e-01 3.74606643e-01 0.99909264 0.76035182 79.50 1.55625027e-01 2.52336547e-01 2.96467337e-01 1.01816176 0.78657018 79.75 1.49350397e-01 2.19197666e-01 2.65241697e-01 0.97269690 0.71892203 80.00 8.97045656e-02 1.83471883e-01 2.04227424e-01 1.11604538 0.56505053 80.25 5.77869935e-02 1.66070157e-01 1.75836952e-01 1.23593347 0.37903635 80.50 -5.74577478e-02 2.19740403e-01 2.27128240e-01 1.82655029 0.48200352 80.75 -3.73529259e-02 2.08538575e-01 2.11857448e-01 1.74803441 0.44135375 81.00 -6.63551173e-02 1.02952609e-01 1.22483637e-01 2.14331022 0.28463376 81.25 -1.18646076e-01 9.90889404e-02 1.54581724e-01 2.44577491 0.32000509 81.50 -1.77013582e-01 1.16004977e-01 2.11638756e-01 2.56146909 0.46661204 81.75 -2.12539689e-01 1.14063362e-01 2.41212707e-01 2.64904232 0.42811566 82.00 -2.83703482e-01 1.43336838e-01 3.17857067e-01 2.67376607 0.57320252 82.25 -3.20279707e-01 1.37237983e-01 3.48444192e-01 2.73676615 0.56122610 82.50 -4.00321999e-01 1.28411053e-01 4.20413013e-01 2.83119192 0.71027311 82.75 -4.51742712e-01 1.51933526e-01 4.76608093e-01 2.81714972 0.73732751 83.00 -4.57855178e-01 1.73099187e-01 4.89484108e-01 2.78013725 0.80176707 83.25 -4.87225245e-01 1.84399037e-01 5.20952440e-01 2.77978524 0.74198642 83.50 -5.54029984e-01 1.91814542e-01 5.86295183e-01 2.80829205 0.77170008 83.75 -5.86069600e-01 1.98770878e-01 6.18859789e-01 2.81460804 0.67147695 84.00 -6.47096144e-01 2.22243551e-01 6.84197059e-01 2.81076714 0.72165891 84.25 -6.03628743e-01 2.44004161e-01 6.51080402e-01 2.75744603 0.67307122 84.50 -6.59175150e-01 2.76987791e-01 7.15006374e-01 2.74379158 0.76262459 84.75 -5.91305842e-01 2.95948448e-01 6.61232246e-01 2.67754529 0.71195319 85.00 -5.68238358e-01 2.56528099e-01 6.23459298e-01 2.71753810 0.73434305 85.25 -6.38585814e-01 2.53303921e-01 6.86989605e-01 2.76396555 0.67875586 85.50 -6.28750821e-01 2.82807147e-01 6.89425469e-01 2.71891164 0.73474371 85.75 -6.80240044e-01 3.29984778e-01 7.56053220e-01 2.68993554 0.70554317 86.00 -7.05719699e-01 2.91537554e-01 7.63566918e-01 2.74983869 0.70155554 86.25 -7.91511181e-01 4.02399480e-01 8.87927525e-01 2.67125247 0.72829018 86.50 -8.11255184e-01 4.54634743e-01 9.29961141e-01 2.63079299 0.75238850 86.75 -7.32961640e-01 4.44505994e-01 8.57215460e-01 2.59644259 0.66635505 87.00 -7.54100900e-01 4.75810854e-01 8.91663690e-01 2.57871579 0.63718157 87.25 -6.57348549e-01 3.67621611e-01 7.53161844e-01 2.63167612 0.47311524 87.50 -5.75056642e-01 3.25627811e-01 6.60850673e-01 2.62635648 0.45716701 87.75 -7.04667330e-01 1.68817351e-01 7.24607027e-01 2.90645403 0.64371770 88.00 -7.82892051e-01 1.55015643e-01 7.98091356e-01 2.94611720 0.73042309 88.25 -8.50476876e-01 2.17826545e-01 8.77928995e-01 2.89085968 0.67070205 88.50 -8.21991500e-01 2.92167785e-01 8.72371504e-01 2.80008070 0.60933413 88.75 -8.32165663e-01 2.03150806e-01 8.56603724e-01 2.90215286 0.58790550 89.00 -8.02664240e-01 1.92679834e-01 8.25466778e-01 2.90600006 0.52073259 89.25 -8.84913498e-01 -6.57243074e-02 8.87350880e-01 -3.06745676 0.45972578 89.50 -8.25042251e-01 -8.95332363e-02 8.29886087e-01 -3.03349609 0.40419489 89.75 -8.02249744e-01 -4.64626748e-02 8.03594072e-01 -3.08374180 0.22410234 90.00 -6.27948933e-01 2.67546848e-01 6.82569542e-01 2.73882058 0.19318118 90.25 -5.62600264e-01 4.77921860e-01 7.38192632e-01 2.43739623 0.49625145 90.50 -7.32354783e-01 3.82059254e-01 8.26022277e-01 2.66074712 0.67102067 90.75 -8.98917318e-01 2.54979499e-01 9.34380484e-01 2.86520088 0.82960136 91.00 -1.03387846e+00 2.39162099e-01 1.06118009e+00 2.91426605 0.80633559 91.25 -1.22878744e+00 3.29031771e-01 1.27207723e+00 2.87996095 0.84666426 91.50 -1.06044235e+00 4.19109701e-01 1.14025915e+00 2.76521238 0.81176280 91.75 -1.00762975e+00 4.16540988e-01 1.09033211e+00 2.74959934 0.94399689 92.00 -1.06084025e+00 3.54532021e-01 1.11851463e+00 2.81906297 0.95021219 92.25 -1.23692516e+00 2.98939274e-01 1.27253626e+00 2.90446039 0.96915086 92.50 -1.32023514e+00 3.34211584e-01 1.36188039e+00 2.89365572 0.93471931 92.75 -1.36592689e+00 4.41301357e-01 1.43544528e+00 2.82909983 0.92303768 93.00 -1.34159355e+00 5.35807285e-01 1.44463237e+00 2.76161981 0.90193793 93.25 -1.25930374e+00 6.33169766e-01 1.40952114e+00 2.67571272 0.89249726 93.50 -1.21428577e+00 5.35430304e-01 1.32709289e+00 2.72629635 0.83479974 93.75 -1.17333825e+00 4.52506945e-01 1.25757114e+00 2.77351113 0.88490762 94.00 -1.25653599e+00 3.68105336e-01 1.30934497e+00 2.85661395 0.89142411 94.25 -1.36790316e+00 2.70121197e-01 1.39431865e+00 2.94663001 0.93737999 94.50 -1.52116171e+00 3.21782362e-01 1.55482373e+00 2.93312860 0.91876635 94.75 -1.60900031e+00 4.21952407e-01 1.66340790e+00 2.88512283 0.92912255 95.00 -1.58960456e+00 5.61168541e-01 1.68574992e+00 2.80222640 0.90596467 95.25 -1.49230104e+00 6.95735095e-01 1.64651441e+00 2.70533537 0.91134040 95.50 -1.25345356e+00 6.56867197e-01 1.41513969e+00 2.65889389 0.87732742 95.75 -1.19714126e+00 6.23034312e-01 1.34956250e+00 2.66173094 0.92385720 96.00 -1.18149347e+00 5.21943771e-01 1.29164706e+00 2.72560710 0.89813866 96.25 -1.23162565e+00 4.78726408e-01 1.32139348e+00 2.77087002 0.90308867 96.50 -1.26792475e+00 5.07844328e-01 1.36584737e+00 2.76062781 0.87585875 96.75 -1.21678750e+00 5.75805008e-01 1.34615127e+00 2.69959977 0.88577511 97.00 -1.03016896e+00 5.02109542e-01 1.14602011e+00 2.68807169 0.82128911 97.25 -9.69058435e-01 3.98889830e-01 1.04794434e+00 2.75110405 0.82640212 97.50 -8.99816433e-01 2.48079529e-01 9.33387950e-01 2.87257563 0.81447458 97.75 -8.65666739e-01 1.17971592e-01 8.73668244e-01 3.00614872 0.76786644 98.00 -6.44859819e-01 -2.28665929e-01 6.84201939e-01 -2.80082761 0.48818495 98.25 -6.53244119e-01 -6.52902604e-01 9.23585236e-01 -2.35645596 0.49857943 98.50 -1.74027620e+00 -1.42761665e+00 2.25092216e+00 -2.45457226 0.72914686 98.75 -2.59467164e+00 -1.15509990e+00 2.84017195e+00 -2.72275299 0.82231309 99.00 -2.83436064e+00 5.98923435e-02 2.83499336e+00 3.12046499 0.91470557 99.25 -2.50406971e+00 2.39994004e-01 2.51554412e+00 3.04604292 0.93509409 99.50 -1.82324535e+00 4.48403089e-02 1.82379666e+00 3.11700393 0.92465854 99.75 -1.69016395e+00 -1.32731821e-01 1.69536778e+00 -3.06322158 0.89977862 100.00 -1.62076155e+00 -8.50019328e-01 1.83013684e+00 -2.65857162 0.85233545 100.25 -1.93384012e+00 -1.02130572e+00 2.18696204e+00 -2.65570048 0.85900196 100.50 -2.79703706e+00 -1.08843871e+00 3.00135222e+00 -2.77048335 0.90503393 100.75 -3.11395572e+00 -7.40972382e-01 3.20089992e+00 -2.90798491 0.93619917 101.00 -3.18531379e+00 -4.56702503e-01 3.21788768e+00 -2.99918563 0.97175970 101.25 -3.23911675e+00 -3.37800101e-01 3.25668332e+00 -3.03768056 0.96817309 101.50 -3.38937320e+00 -9.44867282e-02 3.39068996e+00 -3.11372253 0.98043828 101.75 -3.35777357e+00 -3.59256292e-02 3.35796575e+00 -3.13089382 0.97939136 102.00 -3.42074827e+00 1.08770314e-01 3.42247713e+00 3.10980613 0.98497884 102.25 -3.43131055e+00 1.90356779e-01 3.43658665e+00 3.08617305 0.98355505 102.50 -3.41316670e+00 2.77149209e-01 3.42440047e+00 3.06057039 0.98885556 102.75 -3.31128530e+00 3.07192094e-01 3.32550407e+00 3.04908618 0.98636327 103.00 -3.25404231e+00 2.07606263e-01 3.26065817e+00 3.07787951 0.99153904 103.25 -3.24348840e+00 1.36958295e-01 3.24637868e+00 3.09939211 0.98875546 103.50 -3.23026357e+00 8.25355173e-03 3.23027411e+00 3.13903759 0.99304394 103.75 -3.27765094e+00 -7.47366323e-02 3.27850290e+00 -3.11879472 0.99458469 104.00 -3.35875638e+00 -1.54390621e-01 3.36230291e+00 -3.09565838 0.99466065 104.25 -3.51898430e+00 -3.61207260e-01 3.53747384e+00 -3.03930557 0.98596195 104.50 -3.85535128e+00 -5.59394656e-01 3.89572277e+00 -2.99750256 0.98473154 104.75 -4.20918770e+00 -4.70698559e-01 4.23542421e+00 -3.03022886 0.98287028 105.00 -4.46669044e+00 -3.74053277e-01 4.48232522e+00 -3.05804477 0.98925138 105.25 -4.63953415e+00 -2.66762077e-01 4.64719691e+00 -3.08415829 0.98378014 105.50 -4.91248654e+00 -1.06432889e-01 4.91363938e+00 -3.11993026 0.98856023 105.75 -5.19798146e+00 -1.84736875e-02 5.19801429e+00 -3.13803866 0.98384441 106.00 -5.40914227e+00 3.77600738e-02 5.40927407e+00 3.13461198 0.98862659 106.25 -5.84932853e+00 3.10051139e-01 5.85754009e+00 3.08863593 0.98740360 106.50 -6.15872843e+00 4.87891401e-01 6.17802347e+00 3.06253825 0.99094796 106.75 -6.50829724e+00 9.12965480e-01 6.57201939e+00 3.00222489 0.98063099 107.00 -6.69998650e+00 1.49505412e+00 6.86476554e+00 2.92204657 0.97804476 107.25 -6.58640748e+00 2.15478036e+00 6.92992365e+00 2.82541229 0.97081699 107.50 -6.63840942e+00 2.51762074e+00 7.09978125e+00 2.77910065 0.97366126 107.75 -6.69087605e+00 3.34487347e+00 7.48037438e+00 2.67801255 0.96437159 108.00 -6.44947839e+00 3.75258507e+00 7.46174686e+00 2.61463074 0.96068129 108.25 -5.29939014e+00 5.11991803e+00 7.36865635e+00 2.37341774 0.93999976 108.50 -4.77007821e+00 5.65312790e+00 7.39672232e+00 2.27167673 0.95263120 108.75 -3.16712243e+00 5.70024341e+00 6.52099988e+00 2.07793780 0.94470838 109.00 -2.55632980e+00 5.48963675e+00 6.05565304e+00 2.00660035 0.95617949 109.25 -1.81470085e+00 4.96637823e+00 5.28753741e+00 1.92112167 0.93595337 109.50 -1.10629137e+00 4.47589210e+00 4.61058464e+00 1.81310656 0.91617593 109.75 -5.56566436e-01 3.41519325e+00 3.46024726e+00 1.73234394 0.89710263 110.00 -4.98663313e-01 3.01191069e+00 3.05291190e+00 1.73487173 0.75731328 110.25 8.41725714e-01 3.45696966e+00 3.55796872e+00 1.33195728 0.67402616 110.50 1.13468327e+00 2.96121162e+00 3.17116388e+00 1.20487168 0.80711979 110.75 6.70234243e-01 1.75837840e+00 1.88178334e+00 1.20663075 0.82943464 111.00 5.13471923e-01 1.33988314e+00 1.43490078e+00 1.20483739 0.75631081 111.25 3.53057394e-01 8.89192569e-01 9.56719890e-01 1.19283225 0.67158293 111.50 2.40090273e-01 6.72049302e-01 7.13648095e-01 1.22767650 0.47715276 111.75 3.23759589e-01 2.91360191e-01 4.35558300e-01 0.73277510 0.25365389 112.00 3.17553890e-01 7.67929719e-02 3.26707260e-01 0.23727136 0.11523964 112.25 4.12646392e-01 -2.99908209e-01 5.10119573e-01 -0.62848197 0.24903237 112.50 6.96566151e-01 -4.98101237e-01 8.56334774e-01 -0.62077591 0.35694334 112.75 1.55322329e+00 -1.02163657e+00 1.85909759e+00 -0.58180587 0.63208660 113.00 2.00259592e+00 -2.03832307e+00 2.85747290e+00 -0.79423928 0.64508145 113.25 2.18801521e+00 -3.92242547e+00 4.49141760e+00 -1.06196759 0.82871133 113.50 1.65145449e+00 -5.47948355e+00 5.72293997e+00 -1.27806597 0.75955547 113.75 -1.01853861e+00 -7.59139380e+00 7.65941778e+00 -1.70416999 0.80204053 114.00 -3.61406575e+00 -6.75896707e+00 7.66453568e+00 -2.06182236 0.81096026 114.25 -4.37921898e+00 -4.89057069e+00 6.56469654e+00 -2.30108709 0.88013836 114.50 -3.84134980e+00 -3.73008604e+00 5.35439167e+00 -2.37088863 0.87539215 114.75 -3.39987689e+00 -3.19680708e+00 4.66676958e+00 -2.38696839 0.91591656 115.00 -2.92384764e+00 -3.21551517e+00 4.34608132e+00 -2.30872240 0.90986273 115.25 -2.62928288e+00 -3.08826151e+00 4.05592007e+00 -2.27609078 0.92443572 115.50 -2.11357442e+00 -3.02191057e+00 3.68770122e+00 -2.18113064 0.83600331 115.75 -1.43673664e+00 -3.50049904e+00 3.78387443e+00 -1.96026818 0.87315376 116.00 -7.21231020e-01 -4.05126938e+00 4.11496753e+00 -1.74697650 0.81990876 116.25 -4.87189051e-01 -5.00481475e+00 5.02847132e+00 -1.66783466 0.85419231 116.50 -9.45447213e-01 -6.32477113e+00 6.39504498e+00 -1.71918084 0.87234215 116.75 -1.67110883e+00 -6.81904601e+00 7.02082567e+00 -1.81112482 0.85451954 117.00 -2.75256048e+00 -3.86250813e+00 4.74294826e+00 -2.18995226 0.70018422 117.25 -1.81745795e+00 -3.17956004e+00 3.66234289e+00 -2.09007674 0.73660314 117.50 -2.20125557e-02 -4.56690354e+00 4.56695659e+00 -1.57561631 0.87802471 117.75 5.90162189e-01 -5.23968700e+00 5.27281815e+00 -1.45863593 0.92511033 118.00 1.64820539e+00 -6.70312827e+00 6.90278999e+00 -1.32969340 0.83656814 118.25 2.84657732e+00 -8.39722024e+00 8.86658391e+00 -1.24396305 0.84627542 118.50 4.53300692e-01 -1.12259277e+01 1.12350761e+01 -1.53043845 0.67486871 118.75 -2.87351345e+00 -1.26173349e+01 1.29404103e+01 -1.79472034 0.64004706 119.00 -4.45862893e+00 -6.94964501e+00 8.25693271e+00 -2.14121693 0.41285985 119.25 -3.62086585e+00 -4.39405619e+00 5.69371578e+00 -2.26002323 0.33672371 119.50 -4.36751739e+00 -4.78009480e+00 6.47491424e+00 -2.31112284 0.53695445 119.75 -4.74639437e+00 -5.07775412e+00 6.95067238e+00 -2.32247817 0.68906028 120.00 -4.55462299e+00 -5.82326648e+00 7.39290356e+00 -2.23455318 0.84022322 120.25 -4.32553628e+00 -5.69060439e+00 7.14795372e+00 -2.22074218 0.86194201 120.50 -4.25201233e+00 -5.65598107e+00 7.07599680e+00 -2.21543102 0.87012206 120.75 -4.12103619e+00 -5.82278653e+00 7.13356729e+00 -2.18670003 0.86184688 121.00 -3.66243261e+00 -5.90402877e+00 6.94773116e+00 -2.12602873 0.85642292 121.25 -3.46148051e+00 -6.44703700e+00 7.31752236e+00 -2.06353434 0.85417272 121.50 -2.95912209e+00 -8.16217259e+00 8.68201963e+00 -1.91859954 0.86921304 121.75 -4.07042525e+00 -8.38197179e+00 9.31803696e+00 -2.02287121 0.82090514 122.00 -6.16739735e+00 -8.88783296e+00 1.08180573e+01 -2.17742647 0.88400081 122.25 -6.59600759e+00 -8.16109068e+00 1.04933654e+01 -2.25053318 0.87623292 122.50 -7.04082457e+00 -8.02979979e+00 1.06794614e+01 -2.29066573 0.90706014 122.75 -8.08535126e+00 -9.04195393e+00 1.21297088e+01 -2.30039997 0.87234445 123.00 -1.17768715e+01 -9.73145441e+00 1.52773004e+01 -2.45100820 0.86478443 123.25 -1.40942634e+01 -4.71746222e+00 1.48627962e+01 -2.81860544 0.66967307 123.50 -1.28625098e+01 5.61861965e+00 1.40361336e+01 2.72975193 0.66363913 123.75 -6.68737996e+00 4.79176373e+00 8.22691013e+00 2.51985319 0.50875686 124.00 -3.42501987e+00 2.38364782e+00 4.17283333e+00 2.53358895 0.51377551 124.25 -3.26489034e+00 1.25038815e+00 3.49613779e+00 2.77584412 0.59492962 124.50 -3.42745690e+00 3.41936097e-01 3.44447109e+00 3.04215788 0.73237586 124.75 -4.16717312e+00 4.60738117e-01 4.19256621e+00 3.03147619 0.74181716 125.00 -3.96060510e+00 1.82067404e+00 4.35904195e+00 2.71070491 0.79316128 125.25 -2.72955598e+00 2.20607604e+00 3.50959362e+00 2.46186084 0.77521886 125.50 -1.88148613e+00 2.34566896e+00 3.00701728e+00 2.24682295 0.78564156 125.75 -1.25262040e+00 2.09549501e+00 2.44134332e+00 2.10957322 0.76239021 126.00 -9.77981802e-01 2.02756608e+00 2.25110476e+00 2.02021862 0.82679126 126.25 -4.45731699e-01 1.70100461e+00 1.75843494e+00 1.82707451 0.70829900 126.50 -1.04863512e-02 1.56256874e+00 1.56260393e+00 1.57750720 0.76842732 126.75 5.87251145e-01 1.04548189e+00 1.19912313e+00 1.05901190 0.57947566 127.00 7.04055399e-01 5.43077706e-01 8.89172312e-01 0.65702975 0.48493025 127.25 4.44509506e-02 1.90938225e-01 1.96044109e-01 1.34206761 0.03541349 127.50 -2.48992658e-01 3.26706477e-01 4.10773010e-01 2.22201525 0.16691711 127.75 4.33960596e-02 6.68542666e-01 6.69949636e-01 1.50597584 0.45630537 128.00 2.78054504e-01 7.78372220e-01 8.26545595e-01 1.22769898 0.65865711 128.25 5.96011621e-01 6.77222352e-01 9.02141877e-01 0.84909492 0.75895244 128.50 6.93544955e-01 6.45001112e-01 9.47117226e-01 0.74914795 0.83842835 128.75 8.64729728e-01 5.45671454e-01 1.02250420e+00 0.56292462 0.86209268 129.00 9.35645283e-01 4.70309343e-01 1.04719768e+00 0.46577154 0.88219967 129.25 9.99607627e-01 3.32869325e-01 1.05357363e+00 0.32145051 0.90976194 129.50 1.05437113e+00 3.35315051e-01 1.10640620e+00 0.30790923 0.93302759 129.75 1.11328121e+00 3.31042039e-01 1.16145766e+00 0.28903033 0.94429702 130.00 1.14585289e+00 3.18907078e-01 1.18940345e+00 0.27144474 0.94480750 130.25 1.19931582e+00 2.22213089e-01 1.21972829e+00 0.18320559 0.94479829 130.50 1.28415226e+00 1.74431266e-01 1.29594494e+00 0.13500750 0.93556326 130.75 1.41146726e+00 -1.43173934e-02 1.41153988e+00 -0.01014328 0.96599769 131.00 1.39192160e+00 -9.23287638e-02 1.39498041e+00 -0.06623484 0.96866334 131.25 1.21594769e+00 -1.97407589e-01 1.23186791e+00 -0.16094454 0.95154454 131.50 1.10801697e+00 -1.59677919e-01 1.11946355e+00 -0.14312605 0.94470580 131.75 1.17396793e+00 -1.35308720e-01 1.18173988e+00 -0.11475125 0.96986764 132.00 1.17446022e+00 -1.71510435e-01 1.18691729e+00 -0.14500841 0.96903515 132.25 1.14985417e+00 -2.21624371e-01 1.17101749e+00 -0.19040638 0.96487961 132.50 1.05237185e+00 -2.66395829e-01 1.08556587e+00 -0.24793035 0.94790121 132.75 9.00848917e-01 -2.06200988e-01 9.24146968e-01 -0.22501989 0.92537350 133.00 9.13715589e-01 -1.89593361e-01 9.33178343e-01 -0.20459383 0.92347795 133.25 8.81263286e-01 -2.40618038e-01 9.13521768e-01 -0.26654090 0.92369717 133.50 7.86118863e-01 -2.17806800e-01 8.15734435e-01 -0.27028593 0.86950984 133.75 6.48120163e-01 -1.77127023e-01 6.71888181e-01 -0.26677899 0.85388162 134.00 5.39016545e-01 -1.38248188e-01 5.56463294e-01 -0.25107026 0.69764651 134.25 2.02698084e-01 -4.01124303e-02 2.06628944e-01 -0.19536830 0.22596142 134.50 1.08937933e-01 1.58574562e-01 1.92388578e-01 0.96886054 0.36445602 134.75 6.94836288e-02 3.12653198e-01 3.20281122e-01 1.35211171 0.78345331 135.00 -2.59144974e-02 4.31119845e-01 4.31898000e-01 1.63083382 0.84808581 135.25 -8.42233341e-02 6.22007263e-01 6.27683523e-01 1.70538348 0.90405248 135.50 -9.30986012e-02 8.54457389e-01 8.59514270e-01 1.67932461 0.90845792 135.75 -7.07799856e-02 1.15915206e+00 1.16131103e+00 1.63178247 0.94416092 136.00 5.56488588e-02 1.38250169e+00 1.38362123e+00 1.53056576 0.93430920 136.25 2.09831504e-01 1.60845841e+00 1.62208745e+00 1.44107387 0.96110998 136.50 3.03852343e-01 1.78738152e+00 1.81302480e+00 1.40240754 0.95362748 136.75 3.95882067e-01 1.99240736e+00 2.03135661e+00 1.37465556 0.96116649 137.00 3.25799721e-01 2.32028636e+00 2.34304807e+00 1.43129478 0.92552022 137.25 2.51330937e-01 2.85960716e+00 2.87063065e+00 1.48313157 0.93244454 137.50 5.05715548e-01 3.34029793e+00 3.37836329e+00 1.42053910 0.87423103 137.75 1.15650966e+00 4.02846855e+00 4.19118998e+00 1.29123060 0.85706059 138.00 2.32355562e+00 3.39409666e+00 4.11324724e+00 0.97048950 0.57157412 138.25 3.90373770e+00 1.32641132e+00 4.12292797e+00 0.32754113 0.37981582 138.50 3.10111619e+00 -1.49774495e+00 3.44385853e+00 -0.44993073 0.35177814 138.75 2.93008947e+00 -1.95810822e+00 3.52414700e+00 -0.58911587 0.56514554 139.00 2.85590027e+00 -2.00891405e+00 3.49169043e+00 -0.61302149 0.67894086 139.25 2.80369064e+00 -2.26388614e+00 3.60359011e+00 -0.67927711 0.73362019 139.50 1.71807550e+00 -2.36092767e+00 2.91989090e+00 -0.94171276 0.74335948 139.75 1.25860333e+00 -2.52054772e+00 2.81731134e+00 -1.10767907 0.76035750 140.00 1.66677375e-01 -2.15706918e+00 2.16349920e+00 -1.49367927 0.68483001 140.25 1.70302913e-02 -1.92334652e+00 1.92342191e+00 -1.56194205 0.70643614 140.50 -3.90807929e-01 -1.55410276e+00 1.60248751e+00 -1.81715665 0.61661246 140.75 -5.92446168e-01 -1.45795536e+00 1.57373006e+00 -1.95676836 0.53328348 141.00 -1.44188883e+00 -1.30133606e+00 1.94229733e+00 -2.40738605 0.59317018 141.25 -2.10611435e+00 -1.07378839e+00 2.36405142e+00 -2.67010141 0.59153323 141.50 -3.81886824e+00 9.03182010e-01 3.92421869e+00 2.90935479 0.66297109 141.75 -4.07705349e+00 2.42672004e+00 4.74461119e+00 2.60469957 0.68682216 142.00 -9.57845612e-01 5.32778342e+00 5.41320094e+00 1.74867920 0.64305050 142.25 1.13274813e+00 4.46339679e+00 4.60489188e+00 1.32225745 0.60710991 142.50 2.65050512e+00 2.43908647e+00 3.60198837e+00 0.74388262 0.65676856 142.75 2.50228294e+00 1.47187590e+00 2.90307399e+00 0.53170767 0.61605272 143.00 1.61279620e+00 4.99875330e-01 1.68848657e+00 0.30055392 0.44749166 143.25 1.12763891e+00 2.52671688e-01 1.15560049e+00 0.22043046 0.30225587 143.50 6.74691703e-01 -3.85620527e-02 6.75792813e-01 -0.05709296 0.18021416 143.75 4.30207936e-01 6.92769898e-03 4.30263711e-01 0.01610175 0.07694909 144.00 -2.99008298e-01 -4.68893547e-02 3.02662475e-01 -2.98604322 0.03001292 144.25 -9.53507776e-01 -3.07003228e-02 9.54001881e-01 -3.10940653 0.18948778 144.50 -1.34073003e+00 -7.82647705e-02 1.34301243e+00 -3.08328408 0.38939370 144.75 -1.58676997e+00 9.51594628e-02 1.58962079e+00 3.08169385 0.42502810 145.00 -2.51395394e+00 2.16017045e-01 2.52321774e+00 3.05587599 0.59750233 145.25 -2.89390618e+00 5.74449513e-01 2.95037035e+00 2.94563678 0.56303309 145.50 -4.01872312e+00 1.39025111e+00 4.25240328e+00 2.80853621 0.64283843 145.75 -4.69061078e+00 1.99946493e+00 5.09898907e+00 2.73864711 0.56668879 146.00 -5.29177632e+00 3.46556405e+00 6.32558542e+00 2.56178318 0.52227541 146.25 -4.63853412e+00 4.88509095e+00 6.73647625e+00 2.33031130 0.49714379 146.50 -4.53695355e+00 6.96883535e+00 8.31556454e+00 2.14789858 0.58907881 146.75 -1.74892725e+00 9.13782356e+00 9.30368561e+00 1.75990364 0.56221180 147.00 -1.65971915e+00 1.23833098e+01 1.24940397e+01 1.70403104 0.63881277 147.25 3.46184403e+00 1.32578787e+01 1.37023981e+01 1.31538323 0.47200867 147.50 1.24043070e+01 1.42015123e+01 1.88560278e+01 0.85284504 0.56716405 147.75 1.48645558e+01 1.13941081e+01 1.87291409e+01 0.65399580 0.64085209 148.00 1.44658543e+01 7.94681281e+00 1.65049318e+01 0.50234381 0.64676191 148.25 1.14008826e+01 1.91841419e+00 1.15611607e+01 0.16670722 0.60026065 148.50 1.22163925e+01 -4.24995610e-01 1.22237828e+01 -0.03477494 0.75554395 148.75 9.54090253e+00 -2.53023344e+00 9.87070931e+00 -0.25923124 0.64195680 149.00 7.62918504e+00 -3.66505113e+00 8.46386816e+00 -0.44784402 0.65946406 149.25 6.24689640e+00 -2.21029262e+00 6.62639480e+00 -0.34007612 0.61504431 149.50 6.28486336e+00 -2.42152845e+00 6.73522884e+00 -0.36776601 0.68747311 149.75 5.45180198e+00 -2.58610745e+00 6.03407794e+00 -0.44292463 0.72117585 150.00 4.75106982e+00 -2.81873461e+00 5.52430350e+00 -0.53546677 0.71619612 150.25 3.55041700e+00 -2.92983346e+00 4.60319292e+00 -0.68992395 0.68317909 150.50 3.31319149e+00 -2.50547601e+00 4.15387144e+00 -0.64746511 0.68306404 150.75 2.98108895e+00 -1.70473725e+00 3.43409674e+00 -0.51946414 0.71537371 151.00 2.93167715e+00 -1.66877366e+00 3.37335685e+00 -0.51748074 0.74036304 151.25 2.89485562e+00 -1.44525311e+00 3.23557501e+00 -0.46304644 0.68967500 151.50 2.78280217e+00 -1.41145561e+00 3.12028762e+00 -0.46939625 0.65853818 151.75 3.01955558e+00 -1.46612197e+00 3.35666942e+00 -0.45201470 0.66770574 152.00 2.94722310e+00 -1.38743374e+00 3.25746779e+00 -0.43998292 0.71145819 152.25 3.32060856e+00 -1.15636668e+00 3.51619469e+00 -0.33510548 0.77818211 152.50 3.21678895e+00 -8.03921221e-01 3.31572323e+00 -0.24489790 0.67258624 152.75 3.93184622e+00 -8.40216379e-01 4.02061914e+00 -0.21052861 0.76040033 153.00 3.98396124e+00 -1.07394178e+00 4.12617233e+00 -0.26330758 0.71952203 153.25 2.82080089e+00 -1.35312786e+00 3.12855761e+00 -0.44727315 0.59498701 153.50 2.32700461e+00 -1.41131073e+00 2.72153421e+00 -0.54517969 0.52079160 153.75 2.73837272e+00 -2.41061601e+00 3.64825365e+00 -0.72182935 0.64299423 154.00 2.46724667e+00 -2.83237772e+00 3.75628402e+00 -0.85418699 0.60849114 154.25 1.43010004e+00 -4.10349206e+00 4.34555327e+00 -1.23545125 0.67985045 154.50 1.00548180e+00 -3.57535342e+00 3.71404708e+00 -1.29665126 0.59787468 154.75 1.73317504e-01 -3.19911861e+00 3.20381005e+00 -1.51667260 0.56505260 155.00 -2.43748224e-01 -2.68170405e+00 2.69275877e+00 -1.66144029 0.44428704 155.25 -4.57308104e-01 -2.52390252e+00 2.56499798e+00 -1.75004253 0.52814454 155.50 -2.48143860e-01 -2.34374185e+00 2.35684136e+00 -1.67627844 0.43975690 155.75 5.26306487e-02 -2.14404628e+00 2.14469216e+00 -1.54625391 0.38253900 156.00 -9.34411004e-02 -1.51763220e+00 1.52050608e+00 -1.63228902 0.21663659 156.25 -2.23863740e-01 -1.38953398e+00 1.40745147e+00 -1.73053083 0.24895129 156.50 -2.84195398e-01 -7.97904184e-01 8.47005378e-01 -1.91296372 0.09554629 156.75 -4.61016540e-01 -3.42693782e-01 5.74434747e-01 -2.50236515 0.03935066 157.00 8.80483186e-02 -8.83615829e-01 8.87991802e-01 -1.47147870 0.10377948 157.25 3.23149653e-01 -1.15018534e+00 1.19471838e+00 -1.29690281 0.20704313 157.50 1.62556416e-01 -1.42420443e+00 1.43345137e+00 -1.45714974 0.22182565 157.75 -1.95721115e-01 -2.02964396e+00 2.03905894e+00 -1.66693033 0.37570190 158.00 -1.17877222e+00 -2.10420958e+00 2.41188762e+00 -2.08143472 0.37176608 158.25 -2.29350025e+00 -2.10515811e+00 3.11317106e+00 -2.39898644 0.43030755 158.50 -2.69261006e+00 -7.91543929e-02 2.69377325e+00 -3.11220422 0.35090022 158.75 -2.82639586e+00 1.11123264e+00 3.03699713e+00 2.76699460 0.47143669 159.00 -7.33037767e-01 1.35938238e+00 1.54443026e+00 2.06534350 0.25264066 159.25 7.93853865e-03 1.28894278e+00 1.28896722e+00 1.56463745 0.28944821 159.50 8.80020113e-01 7.49337438e-01 1.15582957e+00 0.70536445 0.26142649 159.75 1.35161220e+00 1.32422370e-02 1.35167707e+00 0.00979705 0.37061732 160.00 1.55249240e+00 -1.36902354e+00 2.06989326e+00 -0.72268133 0.56265647 160.25 1.45499957e+00 -2.01344980e+00 2.48415053e+00 -0.94503671 0.57362910 160.50 5.03706069e-01 -2.81944551e+00 2.86408672e+00 -1.39400716 0.51357400 160.75 1.53508760e-01 -3.14056626e+00 3.14431572e+00 -1.52195587 0.52972694 161.00 2.13338746e-01 -3.45534900e+00 3.46192867e+00 -1.50913301 0.45855027 161.25 5.63302062e-01 -3.68600093e+00 3.72879499e+00 -1.41914762 0.47708021 161.50 7.20698960e-01 -4.01568834e+00 4.07984801e+00 -1.39321599 0.55798395 161.75 3.97240752e-01 -3.90632532e+00 3.92647141e+00 -1.46945303 0.47094444 162.00 1.98557318e+00 -3.11701784e+00 3.69571387e+00 -1.00360681 0.29258866 162.25 2.76699505e+00 -2.13686857e+00 3.49606477e+00 -0.65760252 0.25427475 162.50 2.47334297e+00 -1.76989656e+00 3.04137457e+00 -0.62111182 0.17148671 162.75 1.64801496e+00 -8.12176488e-01 1.83727623e+00 -0.45788799 0.05333138 163.00 1.20367793e+00 1.26027409e+00 1.74273674e+00 0.80836380 0.03475491 163.25 2.14415236e+00 3.87188576e-01 2.17883096e+00 0.17865357 0.06806559 163.50 2.61278327e+00 -1.06441015e+00 2.82127726e+00 -0.38685697 0.08876755 163.75 2.62514599e+00 -1.09139981e+00 2.84298171e+00 -0.39400829 0.09575863 164.00 3.82818825e+00 -1.50317063e+00 4.11272990e+00 -0.37416152 0.12966825 164.25 4.06223481e+00 -2.09783737e+00 4.57194414e+00 -0.47670067 0.17068798 164.50 5.42519868e+00 -3.47896134e+00 6.44483923e+00 -0.57020635 0.32130712 164.75 6.04120621e+00 -2.23026435e+00 6.43974002e+00 -0.35365437 0.38528271 165.00 7.57049134e+00 -2.38212224e+00 7.93642523e+00 -0.30485046 0.58164911 165.25 7.10349038e+00 -1.73532516e+00 7.31238189e+00 -0.23959916 0.57663189 165.50 8.12763685e+00 -2.05827604e+00 8.38421022e+00 -0.24802959 0.64481590 165.75 7.94341073e+00 -1.14521868e+00 8.02554047e+00 -0.14318553 0.70817072 166.00 8.54551150e+00 -8.32603923e-01 8.58597671e+00 -0.09712516 0.82740616 166.25 8.26770788e+00 -7.64678462e-01 8.30299505e+00 -0.09222739 0.81399065 166.50 7.89357368e+00 -7.22113332e-02 7.89390397e+00 -0.00914786 0.85356495 166.75 7.27644479e+00 6.35773294e-01 7.30416706e+00 0.08715283 0.83024730 167.00 7.78281591e+00 1.26040954e+00 7.88421560e+00 0.16055382 0.86784060 167.25 7.26429560e+00 1.38721770e+00 7.39556377e+00 0.18869203 0.78335646 167.50 7.07596337e+00 2.00368464e+00 7.35418314e+00 0.27594374 0.73885439 167.75 7.74458089e+00 2.74523472e+00 8.21674186e+00 0.34065295 0.60015208 168.00 1.03226290e+01 2.64458999e+00 1.06560089e+01 0.25079925 0.68697252 168.25 1.29524930e+01 1.23653846e+00 1.30113835e+01 0.09517876 0.79924915 168.50 1.39929642e+01 2.38698796e-01 1.39950000e+01 0.01705683 0.87920573 168.75 1.47183800e+01 -4.27255121e-01 1.47245800e+01 -0.02902053 0.89646136 169.00 1.50877556e+01 -3.29671793e-01 1.50913569e+01 -0.02184681 0.93248943 169.25 1.53879757e+01 -3.62999918e-01 1.53922566e+01 -0.02358547 0.90075590 169.50 1.61442584e+01 -1.47932394e+00 1.62118931e+01 -0.09137641 0.89936703 169.75 1.54497979e+01 -3.73748278e+00 1.58954406e+01 -0.23735153 0.85300985 170.00 1.68152933e+01 -4.93466648e+00 1.75244122e+01 -0.28544881 0.86627932 170.25 2.23408544e+01 -8.44582902e+00 2.38840072e+01 -0.36143683 0.89414518 170.50 2.33537896e+01 -1.19624747e+01 2.62392891e+01 -0.47338242 0.87985179 170.75 1.96430488e+01 -2.15904708e+01 2.91890013e+01 -0.83259219 0.78009491 171.00 8.98784241e+00 -2.49403478e+01 2.65104179e+01 -1.22491007 0.65964388 171.25 -1.07130346e+01 -1.76153818e+01 2.06172449e+01 -2.11719689 0.56826766 171.50 -1.38921011e+01 -1.25037159e+01 1.86904623e+01 -2.40874475 0.61114359 171.75 -6.84999074e+00 -1.00227262e+00 6.92292738e+00 -2.99630623 0.21062156 172.00 -3.92437189e+00 1.02511292e+00 4.05605119e+00 2.88608493 0.10460517 172.25 2.88218085e+00 -3.77325490e+00 4.74809636e+00 -0.91849332 0.09975631 172.50 3.01058641e+00 -8.31759423e+00 8.84567715e+00 -1.22351202 0.33578572 172.75 1.88728264e-02 -1.04833202e+01 1.04833372e+01 -1.56899606 0.64517416 173.00 -9.64915161e-01 -7.63119401e+00 7.69195575e+00 -1.69657240 0.64857390 173.25 -3.16661116e-01 -6.31116372e+00 6.31910293e+00 -1.62092904 0.70433652 173.50 5.77350430e-01 -5.51275000e+00 5.54290051e+00 -1.46644671 0.66550678 173.75 7.07618497e-01 -4.00818215e+00 4.07016561e+00 -1.39605342 0.52643498 174.00 1.36273321e+00 -3.76355358e+00 4.00267128e+00 -1.22339457 0.38022263 174.25 5.16825179e-01 -7.68601941e+00 7.70337605e+00 -1.50365516 0.66520084 174.50 1.28712522e-01 -8.04222454e+00 8.04325447e+00 -1.55479310 0.79262447 174.75 -3.09048849e-01 -7.44682777e+00 7.45323789e+00 -1.61227326 0.83698540 175.00 -1.94386882e-02 -6.34500590e+00 6.34503568e+00 -1.57385994 0.78579226 175.25 -1.52648759e-01 -6.10051765e+00 6.10242716e+00 -1.59581337 0.82873239 175.50 -4.08982211e-01 -6.14349330e+00 6.15709155e+00 -1.63726985 0.82970760 175.75 -4.20921192e-01 -6.27241161e+00 6.28651907e+00 -1.63780262 0.84821017 176.00 -1.42597601e+00 -5.51927403e+00 5.70050817e+00 -1.82363040 0.77919097 176.25 -2.52016295e+00 -4.87551920e+00 5.48834299e+00 -2.04787349 0.82235199 176.50 -2.34658543e+00 -4.27381843e+00 4.87565249e+00 -2.07291804 0.78971921 176.75 -2.28245014e+00 -3.82604760e+00 4.45513399e+00 -2.10867934 0.83378426 177.00 -1.78862047e+00 -3.05436307e+00 3.53953343e+00 -2.10055675 0.78138235 177.25 -1.55930691e+00 -2.86168375e+00 3.25893724e+00 -2.06970894 0.83137923 177.50 -1.42720005e+00 -2.64695559e+00 3.00720367e+00 -2.06529876 0.80874990 177.75 -1.42331425e+00 -2.32618085e+00 2.72707550e+00 -2.11989620 0.83355237 178.00 -1.07151755e+00 -2.17180324e+00 2.42175126e+00 -2.02913143 0.80033525 178.25 -7.37437056e-01 -2.11187147e+00 2.23692077e+00 -1.90674626 0.78920995 178.50 -9.84661498e-01 -1.80165649e+00 2.05317422e+00 -2.07097246 0.65826405 178.75 -1.07931026e+00 -1.56961417e+00 1.90488825e+00 -2.17317042 0.54802887 179.00 -3.54915736e-01 -7.25905532e-01 8.08024765e-01 -2.02554739 0.18879810 179.25 2.24249986e-01 -3.74058398e-01 4.36128124e-01 -1.03074067 0.08396202 179.50 1.08300456e+00 -7.11859204e-01 1.29601018e+00 -0.58149012 0.43416315 179.75 1.28345203e+00 -9.57688497e-01 1.60137952e+00 -0.64105295 0.57447111 180.00 1.48010439e+00 -1.59149835e+00 2.17337894e+00 -0.82164802 0.67467734 180.25 1.41111451e+00 -1.76854701e+00 2.26252131e+00 -0.89734034 0.75466402 180.50 1.14491057e+00 -2.20607538e+00 2.48547557e+00 -1.09207971 0.71304214 180.75 1.08965860e+00 -2.39067223e+00 2.62729320e+00 -1.14313300 0.72167375 181.00 8.59901674e-01 -2.72355459e+00 2.85607782e+00 -1.26497361 0.76222988 181.25 6.10985652e-01 -2.88928673e+00 2.95318155e+00 -1.36240055 0.79503077 181.50 4.28684386e-01 -2.67033310e+00 2.70452383e+00 -1.41161856 0.78210682 181.75 3.57124426e-01 -2.70646960e+00 2.72992959e+00 -1.43960212 0.80446892 182.00 4.00395413e-01 -2.93511556e+00 2.96229976e+00 -1.43521764 0.76901602 182.25 4.24733761e-01 -2.95585835e+00 2.98621790e+00 -1.42808102 0.79521867 182.50 2.97541516e-01 -3.04346070e+00 3.05797056e+00 -1.47334182 0.85408885 182.75 1.00038165e-01 -3.04551907e+00 3.04716163e+00 -1.53796048 0.83680659 183.00 -3.34231445e-01 -3.24866354e+00 3.26581161e+00 -1.67331837 0.82884136 183.25 -2.53984487e-01 -3.16469456e+00 3.17487004e+00 -1.65088029 0.80091528 183.50 -6.68658444e-01 -3.13576600e+00 3.20626457e+00 -1.78088589 0.81515627 183.75 -8.96227046e-01 -3.12312641e+00 3.24917551e+00 -1.85025165 0.82438732 184.00 -1.12179694e+00 -2.90446501e+00 3.11357437e+00 -1.93937757 0.80906914 184.25 -1.21041983e+00 -2.66747473e+00 2.92925547e+00 -1.99678091 0.75763419 184.50 -1.28488605e+00 -2.21606083e+00 2.56161234e+00 -2.09623517 0.69360245 184.75 -1.17994452e+00 -2.12165360e+00 2.42769089e+00 -2.07834423 0.63387631 185.00 -1.79819143e+00 -1.57275883e+00 2.38894595e+00 -2.42297015 0.57934004 185.25 -1.74782557e+00 -6.70665514e-01 1.87208079e+00 -2.77520410 0.39930984 185.50 -3.29176602e-01 4.40040115e-01 5.49538477e-01 2.21305496 0.05772618 185.75 4.10078617e-01 -3.08809102e-01 5.13349329e-01 -0.64544932 0.04284693 186.00 9.94077098e-01 -1.66964522e+00 1.94316866e+00 -1.03377916 0.52501895 186.25 7.94433366e-01 -1.84932524e+00 2.01274146e+00 -1.16505268 0.59669977 186.50 5.82062627e-01 -1.98548731e+00 2.06904731e+00 -1.28562783 0.66921047 186.75 5.64753080e-01 -2.06018906e+00 2.13619404e+00 -1.30324208 0.58233500 187.00 7.86790017e-01 -2.32840350e+00 2.45774315e+00 -1.24493276 0.65815102 187.25 5.41438894e-01 -2.42234532e+00 2.48211863e+00 -1.35089248 0.69856750 187.50 4.85163496e-01 -2.68632380e+00 2.72978373e+00 -1.39211744 0.78895152 187.75 3.86955446e-01 -2.60683042e+00 2.63539359e+00 -1.42343332 0.73003275 188.00 3.92505480e-01 -2.66906486e+00 2.69777089e+00 -1.42478556 0.78866169 188.25 4.33198613e-01 -2.49933402e+00 2.53659842e+00 -1.39917575 0.74223425 188.50 3.87529136e-01 -2.48898237e+00 2.51897044e+00 -1.41633865 0.74823363 188.75 4.97837918e-01 -2.23598821e+00 2.29073915e+00 -1.35172184 0.67850380 189.00 5.43947608e-01 -1.95708763e+00 2.03127324e+00 -1.29970141 0.65291989 189.25 6.32719278e-01 -1.55581333e+00 1.67955018e+00 -1.18454401 0.56736379 189.50 8.46907548e-01 -1.45047526e+00 1.67962224e+00 -1.04231202 0.63563792 189.75 1.07756268e+00 -1.18165984e+00 1.59920647e+00 -0.83144214 0.60842523 190.00 1.23351626e+00 -1.25452611e+00 1.75937436e+00 -0.79384229 0.71768765 190.25 1.57302414e+00 -1.32939524e+00 2.05953797e+00 -0.70165454 0.75114241 190.50 1.67487705e+00 -1.43615703e+00 2.20630011e+00 -0.70881490 0.80780552 190.75 1.42718669e+00 -1.50987471e+00 2.07763892e+00 -0.81354404 0.78544307 191.00 1.27821319e+00 -1.57410968e+00 2.02772046e+00 -0.88876719 0.81524225 191.25 1.03055641e+00 -1.88326488e+00 2.14679601e+00 -1.07009153 0.63635329 191.50 6.62481131e-01 -2.18359490e+00 2.28187816e+00 -1.27623223 0.42859524 191.75 -5.30984426e-02 1.15888099e-01 1.27473512e-01 2.00043783 0.00109164 192.00 5.04731337e-01 1.15005884e+00 1.25594151e+00 1.15723291 0.14504469 192.25 1.71116820e+00 8.21937210e-01 1.89833543e+00 0.44779374 0.44141295 192.50 2.13677869e+00 1.00994061e+00 2.36343039e+00 0.44152620 0.60126267 192.75 2.07821038e+00 6.28841932e-01 2.17126704e+00 0.29382959 0.60267043 193.00 2.04343362e+00 4.30794510e-01 2.08834980e+00 0.20777642 0.64607273 193.25 1.81770135e+00 4.02776961e-01 1.86179147e+00 0.21806247 0.60395050 193.50 1.70625659e+00 3.09484171e-01 1.73409688e+00 0.17943121 0.55865996 193.75 1.62752099e+00 3.04650251e-01 1.65578874e+00 0.18504525 0.64723661 194.00 1.61748127e+00 3.63815745e-01 1.65789250e+00 0.22124527 0.62426484 194.25 1.70373050e+00 5.98753730e-01 1.80588030e+00 0.33795432 0.63375163 194.50 1.80899588e+00 5.10073782e-01 1.87953222e+00 0.27483005 0.62768449 194.75 2.04134326e+00 2.18892702e-01 2.05304562e+00 0.10682157 0.65645851 195.00 1.90036270e+00 1.55754691e-01 1.90673488e+00 0.08177772 0.59653825 195.25 2.19474906e+00 2.24617331e-01 2.20621314e+00 0.10198797 0.73490217 195.50 2.17934843e+00 1.22730272e-01 2.18280148e+00 0.05625570 0.74501824 195.75 2.28370206e+00 5.53373449e-02 2.28437242e+00 0.02422668 0.84309806 196.00 2.33933195e+00 -3.49704665e-02 2.33959332e+00 -0.01494780 0.81067569 196.25 2.55972860e+00 -3.14736712e-01 2.57900556e+00 -0.12234298 0.81111987 196.50 2.32083915e+00 -6.73892405e-01 2.41669719e+00 -0.28259485 0.76837191 196.75 1.87784409e+00 -1.07238703e+00 2.16247829e+00 -0.51887842 0.79759022 197.00 1.45356835e+00 -9.67669031e-01 1.74620855e+00 -0.58734670 0.74863620 197.25 1.07745085e+00 -7.51252221e-01 1.31349923e+00 -0.60887770 0.72874787 197.50 8.12817179e-01 -3.93425880e-01 9.03025852e-01 -0.45078817 0.48239350 197.75 7.14492743e-01 4.88890805e-02 7.16163405e-01 0.06831839 0.48607868 198.00 8.15747848e-01 4.07865425e-01 9.12030020e-01 0.46363927 0.49387708 198.25 1.00586038e+00 8.69202256e-01 1.32938620e+00 0.71264490 0.65492460 198.50 1.36034342e+00 7.59745227e-01 1.55812292e+00 0.50934201 0.63258762 198.75 1.68955493e+00 7.38564980e-01 1.84392898e+00 0.41210473 0.72939475 199.00 1.73723057e+00 6.41971411e-01 1.85205220e+00 0.35397283 0.60520949 199.25 2.08569412e+00 3.45257616e-01 2.11407729e+00 0.16404844 0.69966534 199.50 1.69905815e+00 1.48205618e-02 1.69912279e+00 0.00872259 0.61783699 199.75 1.48859610e+00 -3.63374930e-02 1.48903954e+00 -0.02440573 0.60250186 200.00 1.24384443e+00 2.02554241e-01 1.26022903e+00 0.16142832 0.49503334 200.25 1.22592105e+00 3.07965742e-01 1.26401160e+00 0.24611879 0.49596063 200.50 1.13623608e+00 1.91303816e-01 1.15222809e+00 0.16680188 0.29317767 200.75 1.15801024e+00 2.55952717e-01 1.18595932e+00 0.21753066 0.30664612 201.00 1.25398244e+00 4.22148752e-01 1.32313322e+00 0.32472940 0.28574843 201.25 1.30954344e+00 2.50768113e-01 1.33333742e+00 0.18920232 0.26923611 201.50 1.36299701e+00 -1.84042155e-01 1.37536627e+00 -0.13421579 0.26453715 201.75 1.43082605e+00 -2.86618774e-01 1.45925101e+00 -0.19770034 0.33492724 202.00 9.61179901e-01 -3.87652158e-01 1.03640774e+00 -0.38335539 0.19395751 202.25 1.05894781e+00 -1.85758299e-01 1.07511702e+00 -0.17365103 0.21300593 202.50 1.01363478e+00 -1.26251971e-01 1.02146710e+00 -0.12391554 0.15129095 202.75 1.22732866e+00 -5.19913415e-02 1.22842938e+00 -0.04233607 0.18524024 203.00 9.40650834e-01 -4.77658378e-02 9.41862818e-01 -0.05073598 0.15562691 203.25 9.72872043e-01 -2.26975238e-01 9.98998384e-01 -0.22920441 0.16222594 203.50 8.79641860e-01 7.01238528e-02 8.82432522e-01 0.07955041 0.11788728 203.75 7.61938240e-01 6.01554581e-02 7.64309205e-01 0.07878714 0.10351240 204.00 1.10835381e+00 -9.46852331e-02 1.11239088e+00 -0.08522179 0.22359473 204.25 1.08187551e+00 -1.08607671e-01 1.08731331e+00 -0.10005312 0.23027392 204.50 9.47509906e-01 1.03887168e-01 9.53188106e-01 0.10920609 0.24584396 204.75 9.75253332e-01 1.05045139e-01 9.80894257e-01 0.10729696 0.23169320 205.00 1.04581078e+00 -3.81658640e-01 1.11327602e+00 -0.34992229 0.27115505 205.25 9.33483748e-01 -2.08222258e-01 9.56424810e-01 -0.21946652 0.21365444 205.50 1.13688049e+00 -1.20109247e-01 1.14320754e+00 -0.10525763 0.31480545 205.75 1.13601482e+00 -1.36907833e-01 1.14423487e+00 -0.11993746 0.30141956 206.00 1.17788651e+00 -2.60598032e-01 1.20636974e+00 -0.21773471 0.34415428 206.25 1.37706547e+00 -4.31547433e-01 1.44310170e+00 -0.30368813 0.42434496 206.50 1.60851859e+00 -2.98560641e-01 1.63599221e+00 -0.18352362 0.51969588 206.75 1.40587375e+00 -2.22202337e-01 1.42332529e+00 -0.15675613 0.39351145 207.00 1.67017735e+00 -2.25908081e-01 1.68538626e+00 -0.13444400 0.51837628 207.25 1.61527031e+00 -2.35521035e-01 1.63235055e+00 -0.14478872 0.47221406 207.50 1.81997065e+00 -3.17761846e-01 1.84750258e+00 -0.17285484 0.63160041 207.75 1.66126955e+00 -4.73468168e-01 1.72742253e+00 -0.27764269 0.54135128 208.00 1.90174431e+00 -8.43022534e-01 2.08022076e+00 -0.41725915 0.63449349 208.25 1.77503610e+00 -6.48773395e-01 1.88988361e+00 -0.35041486 0.58673353 208.50 1.66948372e+00 -7.27287235e-01 1.82102241e+00 -0.41084485 0.53378884 208.75 1.38554846e+00 -6.24291388e-01 1.51969874e+00 -0.42333073 0.31846167 209.00 6.79513326e-01 -5.56723024e-01 8.78452551e-01 -0.68639697 0.14328628 209.25 5.31466713e-01 -4.41183279e-01 6.90723934e-01 -0.69284126 0.09806944 209.50 3.90994523e-01 -3.73702542e-01 5.40860710e-01 -0.76278917 0.07305473 209.75 1.81266445e-01 -9.60617136e-02 2.05147208e-01 -0.48731765 0.00974495 210.00 7.23549633e-02 1.79802365e-01 1.93814683e-01 1.18821077 0.00952774 210.25 4.03482040e-01 3.02753948e-01 5.04438014e-01 0.64372697 0.06571134 210.50 5.84612646e-01 3.65409234e-01 6.89417040e-01 0.55863170 0.13060815 210.75 4.70422052e-01 4.01445649e-01 6.18429879e-01 0.70644922 0.09379389 211.00 4.09817429e-01 4.80079976e-01 6.31210827e-01 0.86419049 0.10331367 211.25 3.82469394e-01 2.59355106e-01 4.62112442e-01 0.59588095 0.05824037 211.50 4.12261657e-01 3.55075834e-01 5.44094222e-01 0.71101068 0.08238152 211.75 2.61528092e-01 3.57578511e-01 4.43011664e-01 0.93931468 0.04655350 212.00 2.06768403e-01 3.64749834e-01 4.19279875e-01 1.05508789 0.03823494 212.25 1.33979704e-01 1.45814230e-01 1.98021087e-01 0.82767026 0.00784260 212.50 1.08526627e-01 2.19837851e-01 2.45166698e-01 1.11222818 0.01266659 212.75 1.83029601e-01 -1.84242587e-01 2.59702071e-01 -0.78870084 0.01696271 213.00 1.70361275e-01 -2.13257963e-01 2.72950404e-01 -0.89675656 0.01819840 213.25 3.61618294e-01 -1.81701657e-01 4.04701473e-01 -0.46562014 0.04315776 213.50 3.17287299e-01 -1.55852007e-01 3.53498343e-01 -0.45658409 0.03355261 213.75 2.86704612e-01 5.43505713e-02 2.91810759e-01 0.18734682 0.01693694 214.00 2.61317197e-01 1.60895536e-01 3.06877909e-01 0.55189075 0.02027786 214.25 1.62145873e-01 1.42500144e-01 2.15864715e-01 0.72100026 0.00832016 214.50 3.89629915e-01 2.03883352e-01 4.39749806e-01 0.48209328 0.03043908 214.75 5.13437900e-01 3.17583438e-01 6.03719900e-01 0.55394263 0.05090474 215.00 4.74771650e-01 6.36640071e-02 4.79021112e-01 0.13329879 0.03252578 215.25 3.51493161e-01 4.23410227e-02 3.54034186e-01 0.11988281 0.02066789 215.50 2.97274331e-01 6.15668300e-02 3.03582777e-01 0.20421731 0.01668186 215.75 6.61450506e-02 2.06644637e-01 2.16972749e-01 1.26101100 0.01139232 216.00 1.22349687e-01 9.92561640e-02 1.57547555e-01 0.68156306 0.00614149 216.25 1.82152086e-02 1.11324662e-01 1.12805028e-01 1.40861109 0.00276168 216.50 5.75241201e-02 -4.78253127e-02 7.48083213e-02 -0.69359373 0.00145173 216.75 8.18891789e-02 -1.28137608e-01 1.52069340e-01 -1.00214164 0.00637184 217.00 1.56931616e-01 -1.21571926e-01 1.98512633e-01 -0.65911068 0.01070493 217.25 1.86170610e-01 -1.45990453e-01 2.36585520e-01 -0.66501717 0.01534429 217.50 3.52721015e-01 -2.24126068e-01 4.17905023e-01 -0.56605745 0.05150874 217.75 4.28288286e-01 -5.79911645e-01 7.20921890e-01 -0.93466967 0.20009116 218.00 4.41727171e-01 -5.36991065e-01 6.95328913e-01 -0.88242787 0.15051459 218.25 4.77986468e-01 -6.75160642e-01 8.27232106e-01 -0.95474829 0.22783148 218.50 3.77886237e-01 -7.75495826e-01 8.62665511e-01 -1.11737366 0.28140471 218.75 3.08090627e-01 -8.70082314e-01 9.23018455e-01 -1.23047926 0.32722871 219.00 2.51183388e-01 -7.03841086e-01 7.47318787e-01 -1.22800984 0.23583824 219.25 2.37050018e-01 -6.96036153e-01 7.35295204e-01 -1.24254570 0.34017662 219.50 3.84207353e-01 -6.46308270e-01 7.51884080e-01 -1.03445695 0.31664302 219.75 3.66568276e-01 -5.58192217e-01 6.67795517e-01 -0.98972118 0.35586686 220.00 3.38162712e-01 -5.84108678e-01 6.74934788e-01 -1.04600757 0.31169463 220.25 3.45230998e-01 -5.52410791e-01 6.51415477e-01 -1.01223053 0.35470125 220.50 3.20870102e-01 -4.08284614e-01 5.19282148e-01 -0.90471345 0.23840592 220.75 3.85018802e-01 -3.25504102e-01 5.04174968e-01 -0.70183140 0.25721731 221.00 5.60642203e-01 4.73461639e-02 5.62637840e-01 0.08424997 0.23584671 221.25 7.06938683e-01 1.46537879e-01 7.21966517e-01 0.20439058 0.42104737 221.50 1.07557404e+00 2.47786255e-02 1.07585942e+00 0.02303351 0.56487699 221.75 1.34315916e+00 -1.26714765e-01 1.34912310e+00 -0.09406244 0.69510716 222.00 1.47060577e+00 -1.70135411e-01 1.48041460e+00 -0.11517866 0.76585976 222.25 1.54150682e+00 -2.00139882e-01 1.55444500e+00 -0.12911169 0.80646748 222.50 1.61477124e+00 -4.05694621e-01 1.66495474e+00 -0.24614509 0.82533745 222.75 1.70807052e+00 -5.58818236e-01 1.79715963e+00 -0.31618742 0.84319604 223.00 1.61219333e+00 -7.95276104e-01 1.79767389e+00 -0.45826385 0.81016876 223.25 1.61559671e+00 -8.67455006e-01 1.83374778e+00 -0.49274979 0.85340202 223.50 1.37026421e+00 -8.87650985e-01 1.63265069e+00 -0.57482392 0.86425155 223.75 1.36293828e+00 -9.14203636e-01 1.64114869e+00 -0.59083067 0.85823223 224.00 1.49275627e+00 -8.56242742e-01 1.72089306e+00 -0.52078037 0.84781166 224.25 1.59139519e+00 -8.85635639e-01 1.82123286e+00 -0.50783153 0.86248327 224.50 1.56492426e+00 -1.13429444e+00 1.93277309e+00 -0.62719272 0.87708254 224.75 1.41568029e+00 -1.22619472e+00 1.87288659e+00 -0.71379688 0.87136498 225.00 1.03998592e+00 -1.23824207e+00 1.61703869e+00 -0.87220157 0.86950329 225.25 9.14088566e-01 -1.18461254e+00 1.49628365e+00 -0.91359195 0.86116298 225.50 7.85410728e-01 -1.09590030e+00 1.34828316e+00 -0.94896269 0.84080314 225.75 7.17289975e-01 -1.01341371e+00 1.24157652e+00 -0.95485742 0.76166091 226.00 4.84647003e-01 -7.90832344e-01 9.27522784e-01 -1.02099526 0.70171560 226.25 5.32465289e-01 -5.76206616e-01 7.84559334e-01 -0.82483152 0.67373655 226.50 7.32345910e-01 -2.78912371e-01 7.83659775e-01 -0.36388768 0.74274002 226.75 8.86355638e-01 -1.51929811e-01 8.99282483e-01 -0.16975978 0.74153585 227.00 1.25863208e+00 -1.20845452e-01 1.26442016e+00 -0.09571991 0.73843114 227.25 1.46274613e+00 -2.03681004e-01 1.47685889e+00 -0.13835600 0.60564246 227.50 1.62310059e+00 -9.89574214e-01 1.90097676e+00 -0.54750777 0.57029731 227.75 8.52522621e-01 -1.16919053e+00 1.44699734e+00 -0.94076920 0.42976945 228.00 1.61477645e-01 -7.40403759e-01 7.57807862e-01 -1.35606472 0.29313275 228.25 -2.71842680e-03 6.55159053e-02 6.55722784e-02 1.61226516 0.00333833 228.50 2.14813685e-01 7.91762772e-01 8.20386011e-01 1.30586328 0.44967739 228.75 3.86768737e-01 1.05387079e+00 1.12260131e+00 1.21905928 0.46137512 229.00 5.83267862e-01 1.54064401e+00 1.64735709e+00 1.20888457 0.49665682 229.25 1.17776928e+00 1.34023630e+00 1.78420117e+00 0.84983095 0.27570307 229.50 2.12159169e+00 -2.19951401e-01 2.13296270e+00 -0.10330377 0.31665151 229.75 1.28936492e+00 -6.05517663e-01 1.42446956e+00 -0.43905348 0.30355585 230.00 1.25418321e+00 -3.60873876e-01 1.30506915e+00 -0.28016795 0.42845713 230.25 1.05327724e+00 -5.17610365e-02 1.05454832e+00 -0.04910334 0.31560714 230.50 1.16007250e+00 1.43655234e-01 1.16893329e+00 0.12320576 0.29591561 230.75 1.28497520e+00 2.41301405e-01 1.30743552e+00 0.18562501 0.23317401 231.00 1.70781480e+00 2.50796352e-01 1.72613157e+00 0.14581000 0.32134409 231.25 1.41047816e+00 6.94435818e-01 1.57216085e+00 0.45750142 0.26510292 231.50 1.12749665e+00 1.09207362e+00 1.56967305e+00 0.76944011 0.23153646 231.75 7.57650566e-01 1.11511103e+00 1.34814947e+00 0.97400299 0.11342151 232.00 8.54956980e-01 1.57033696e+00 1.78799039e+00 1.07223051 0.15736710 232.25 4.61039910e-01 1.25203179e+00 1.33421940e+00 1.21797118 0.10037500 232.50 -1.61261703e-01 1.04532506e+00 1.05769080e+00 1.72385912 0.04805336 232.75 -1.26450056e+00 2.96090439e-01 1.29870366e+00 2.91158064 0.06454747 233.00 -1.77965816e+00 6.43768917e-01 1.89251726e+00 2.79449986 0.15225331 233.25 -2.34792090e+00 -3.64908439e-01 2.37610832e+00 -2.98740849 0.26421324 233.50 -2.53869090e+00 -5.05688320e-01 2.58856565e+00 -2.94497361 0.28799613 233.75 -2.14454373e+00 -6.17391559e-01 2.23164516e+00 -2.86128313 0.38555911 234.00 -2.14996182e+00 -7.46054255e-01 2.27572687e+00 -2.80758567 0.45095610 234.25 -2.12366002e+00 -1.11137747e+00 2.39689211e+00 -2.65945480 0.57690736 234.50 -1.91262800e+00 -1.32229545e+00 2.32521206e+00 -2.53669565 0.56240121 234.75 -1.47086933e+00 -9.88656362e-01 1.77225788e+00 -2.54979809 0.43007872 235.00 -1.61287076e+00 -1.09834926e+00 1.95133882e+00 -2.54373917 0.53679756 235.25 -1.74576653e+00 -1.23473258e+00 2.13828560e+00 -2.52600250 0.71203940 235.50 -1.68548350e+00 -1.16029993e+00 2.04625281e+00 -2.53868916 0.69092616 235.75 -1.46036476e+00 -8.82243941e-01 1.70617103e+00 -2.59814504 0.75632957 236.00 -1.30105503e+00 -9.03663284e-01 1.58409328e+00 -2.53452574 0.73823678 236.25 -1.00147648e+00 -9.66087645e-01 1.39150296e+00 -2.37417867 0.68440779 236.50 -6.36140853e-01 -9.59776636e-01 1.15145403e+00 -2.15611788 0.50039922 236.75 3.35189844e-02 -1.07945725e+00 1.07997754e+00 -1.53975460 0.45335231 237.00 4.23257470e-01 -1.24417154e+00 1.31419546e+00 -1.24288553 0.42223816 237.25 8.86055803e-01 -2.09118323e+00 2.27115437e+00 -1.17001860 0.46695088 237.50 8.17453512e-01 -1.82923195e+00 2.00357674e+00 -1.15053713 0.29033260 237.75 1.10703067e+00 -7.77933772e-01 1.35303284e+00 -0.61254985 0.12141818 238.00 3.78685231e-01 6.87080501e-01 7.84526685e-01 1.06706972 0.04498137 238.25 -1.01474175e+00 2.05201949e+00 2.28921052e+00 2.03004136 0.33493126 238.50 -1.10953550e+00 1.78059118e+00 2.09799284e+00 2.12804806 0.47300470 238.75 -1.10814408e+00 1.78288139e+00 2.09920207e+00 2.12690853 0.68869511 239.00 -1.24608373e+00 1.33340016e+00 1.82501525e+00 2.32235706 0.73814853 239.25 -1.25184314e+00 9.55039338e-01 1.57455117e+00 2.48988239 0.84698920 239.50 -1.28824136e+00 6.79873779e-01 1.45663797e+00 2.65598962 0.80227584 239.75 -1.28468865e+00 5.08298410e-01 1.38159046e+00 2.76483426 0.81100130 240.00 -1.18525909e+00 3.16429399e-01 1.22677083e+00 2.88070647 0.80366937 240.25 -1.29078498e+00 2.34413206e-01 1.31189764e+00 2.96194537 0.87673352 240.50 -1.43536500e+00 2.08468081e-01 1.45042463e+00 2.99736414 0.85707112 240.75 -1.51162900e+00 1.83379113e-01 1.52271144e+00 3.02087031 0.86773262 241.00 -1.65516417e+00 4.41354566e-01 1.71299804e+00 2.88100298 0.85502700 241.25 -1.62905146e+00 6.24194395e-01 1.74454215e+00 2.77568351 0.88926400 241.50 -1.45662119e+00 6.00645265e-01 1.57560148e+00 2.75048086 0.86863533 241.75 -1.39477422e+00 5.74573279e-01 1.50848585e+00 2.75082961 0.85409923 242.00 -1.38221261e+00 6.64403610e-01 1.53360486e+00 2.69351919 0.85548892 242.25 -1.37552094e+00 7.14628008e-01 1.55008098e+00 2.66244133 0.88373609 242.50 -1.44459132e+00 7.15369760e-01 1.61201674e+00 2.68178789 0.81179251 242.75 -1.59338297e+00 1.02652096e+00 1.89541937e+00 2.56927734 0.83926267 243.00 -1.69263827e+00 1.25682706e+00 2.10823114e+00 2.50289242 0.86741487 243.25 -1.61792537e+00 1.43002624e+00 2.15931878e+00 2.41776425 0.86364745 243.50 -1.58486556e+00 1.94517954e+00 2.50908794e+00 2.25447612 0.81306956 243.75 -1.39641726e+00 2.22040101e+00 2.62300626e+00 2.13219750 0.79434747 244.00 -1.11286311e+00 2.80154996e+00 3.01448942e+00 1.94891355 0.79755567 244.25 -7.85158694e-01 3.31625410e+00 3.40793419e+00 1.80327620 0.80202410 244.50 8.28747026e-01 3.67745696e+00 3.76968318e+00 1.34914047 0.72096438 244.75 2.10588067e+00 3.45784514e+00 4.04863266e+00 1.02377427 0.76016547 245.00 3.50800738e+00 2.25045939e+00 4.16781516e+00 0.57039127 0.77282456 245.25 3.66161848e+00 1.11937882e+00 3.82889786e+00 0.29668342 0.74165600 245.50 3.35518251e+00 -1.98516484e-01 3.36105020e+00 -0.05909822 0.81317293 245.75 2.85790093e+00 -4.41269605e-01 2.89176704e+00 -0.15319364 0.77897130 246.00 1.96780550e+00 -8.17111755e-01 2.13071117e+00 -0.39357497 0.76338854 246.25 1.76244489e+00 -8.97477659e-01 1.97779628e+00 -0.47099884 0.75492110 246.50 1.33315073e+00 -9.16278460e-01 1.61767027e+00 -0.60215354 0.71363549 246.75 1.15956830e+00 -8.90644511e-01 1.46213758e+00 -0.65497403 0.65462891 247.00 1.11503072e+00 -7.80860050e-01 1.36126262e+00 -0.61092971 0.59439920 247.25 9.58326381e-01 -7.33648063e-01 1.20690883e+00 -0.65337991 0.49099401 247.50 8.22588242e-01 -7.44953486e-01 1.10977796e+00 -0.73591216 0.48177738 247.75 7.45886086e-01 -7.17657415e-01 1.03507402e+00 -0.76611266 0.42145223 248.00 7.10443572e-01 -6.18495039e-01 9.41948078e-01 -0.71631880 0.45784889 248.25 6.52255633e-01 -5.21151116e-01 8.34886756e-01 -0.67412983 0.33676539 248.50 5.22398787e-01 -6.50162546e-01 8.34033470e-01 -0.89393125 0.33756256 248.75 5.39636835e-01 -5.63385899e-01 7.80135619e-01 -0.80692573 0.25973342 249.00 6.59319180e-01 -5.61441998e-01 8.65978578e-01 -0.70539213 0.38459309 249.25 5.31557478e-01 -5.09100647e-01 7.36027731e-01 -0.76382206 0.28004559 249.50 4.88674853e-01 -4.77219899e-01 6.83038758e-01 -0.77353930 0.24128552 249.75 2.71536195e-01 -7.20572375e-01 7.70036657e-01 -1.21041871 0.13393908 250.00 4.40390766e-01 -7.34270598e-01 8.56211036e-01 -1.03054868 0.05004099 250.25 4.80040702e-01 -4.44034324e-01 6.53915558e-01 -0.74645309 0.04624279 250.50 6.95570899e-01 -4.21402479e-01 8.13264364e-01 -0.54470025 0.25139437 250.75 5.06507828e-01 -4.74008416e-01 6.93710428e-01 -0.75226509 0.18982313 251.00 4.63290894e-01 -4.95684558e-01 6.78484807e-01 -0.81916478 0.23869069 251.25 6.18213984e-01 -6.90976122e-01 9.27165860e-01 -0.84091902 0.34389124 251.50 6.27600932e-01 -7.31932757e-01 9.64162066e-01 -0.86198894 0.48683452 251.75 6.29741176e-01 -4.99621157e-01 8.03862706e-01 -0.67068848 0.37113540 252.00 7.65747529e-01 -3.14673080e-01 8.27881891e-01 -0.38989810 0.34500927 252.25 1.22361410e+00 -4.33594358e-01 1.29816622e+00 -0.34054970 0.53426796 252.50 1.56360262e+00 -6.24310094e-01 1.68363186e+00 -0.37988269 0.67834630 252.75 1.59963122e+00 -9.86978150e-01 1.87961323e+00 -0.55282839 0.64267569 253.00 1.87146180e+00 -1.45577792e+00 2.37100371e+00 -0.66110859 0.74804973 253.25 1.55541613e+00 -2.05066477e+00 2.57381921e+00 -0.92188143 0.71994010 253.50 1.07377523e+00 -2.50307188e+00 2.72366703e+00 -1.16555690 0.76774953 253.75 6.36507060e-01 -2.49473368e+00 2.57465287e+00 -1.32098563 0.77206659 254.00 2.57650171e-01 -2.61104725e+00 2.62372852e+00 -1.47243780 0.80054883 254.25 7.24519035e-02 -2.54868060e+00 2.54971019e+00 -1.54237676 0.82124453 254.50 -1.11073807e-01 -2.41654998e+00 2.41910132e+00 -1.61672779 0.82015233 254.75 -1.78534051e-01 -2.34733831e+00 2.35411800e+00 -1.64670826 0.85141763 255.00 -1.43822461e-01 -2.35073044e+00 2.35512600e+00 -1.63190219 0.84258325 255.25 -3.31806153e-01 -2.24335803e+00 2.26776334e+00 -1.71763774 0.80298005 255.50 -3.14035510e-01 -2.32662726e+00 2.34772501e+00 -1.70496008 0.81804164 255.75 -4.08976844e-01 -2.51318383e+00 2.54624331e+00 -1.73211480 0.80724875 256.00 -4.87332350e-01 -2.43091999e+00 2.47928716e+00 -1.76864607 0.75490199 256.25 -1.06842605e+00 -2.43161063e+00 2.65598653e+00 -1.98479225 0.63243858 256.50 -1.48859236e+00 -2.71791104e+00 3.09886231e+00 -2.07186986 0.62144919 256.75 -1.88111341e+00 -3.34157047e+00 3.83466829e+00 -2.08352218 0.66936181 257.00 -2.45696023e+00 -2.92242038e+00 3.81800922e+00 -2.26988275 0.58269414 257.25 -3.52985791e+00 -9.87896642e-01 3.66549268e+00 -2.86870574 0.50993731 257.50 -3.07647217e+00 1.18756024e-01 3.07876339e+00 3.10301044 0.53616439 257.75 -2.32406559e+00 9.04786108e-01 2.49397650e+00 2.77033408 0.59607677 258.00 -1.76589443e+00 1.21275204e+00 2.14223030e+00 2.53980552 0.57747006 258.25 -1.19209150e+00 1.23595455e+00 1.71716796e+00 2.33813129 0.50353678 258.50 -6.89123934e-01 9.02197826e-01 1.13527649e+00 2.22308876 0.31844016 258.75 -1.64509394e-01 1.11479304e+00 1.12686594e+00 1.71730836 0.43981466 259.00 -1.07883182e-01 9.85431176e-01 9.91319012e-01 1.67984021 0.41453299 259.25 1.29203522e-01 7.98162093e-01 8.08551963e-01 1.41031214 0.35448429 259.50 1.43043517e-01 5.49158115e-01 5.67482232e-01 1.31598074 0.22271925 259.75 1.30734837e-01 3.15031116e-01 3.41080932e-01 1.17743449 0.10541731 260.00 1.90038126e-01 1.81308653e-01 2.62654368e-01 0.76189489 0.07312571 260.25 3.59715004e-01 1.88631487e-01 4.06173266e-01 0.48296985 0.23384304 260.50 4.12273767e-01 -6.86756048e-02 4.17954540e-01 -0.16506209 0.19093556 260.75 4.92485692e-01 -9.44948471e-02 5.01469274e-01 -0.18956934 0.28392824 261.00 3.94373332e-01 -2.27201883e-01 4.55138463e-01 -0.52266705 0.22396969 261.25 3.57063559e-01 -3.26149722e-01 4.83599035e-01 -0.74018130 0.28210148 261.50 4.24086953e-01 -5.33811412e-01 6.81765625e-01 -0.89944816 0.40473246 261.75 4.01552401e-01 -7.92580022e-01 8.88497283e-01 -1.10185118 0.57931315 262.00 2.67145681e-01 -8.43568073e-01 8.84858129e-01 -1.26410299 0.50017036 262.25 -3.22065051e-02 -7.90910777e-01 7.91566243e-01 -1.61149462 0.54441237 262.50 -1.48697013e-01 -6.61659757e-01 6.78162543e-01 -1.79185695 0.56864857 262.75 -2.22792965e-01 -6.20607595e-01 6.59386452e-01 -1.91545899 0.62562105 263.00 -1.91163779e-01 -4.90745899e-01 5.26664151e-01 -1.94225063 0.53929732 263.25 -2.11385004e-01 -4.36915386e-01 4.85364476e-01 -2.02141005 0.57412078 263.50 -9.83392288e-02 -4.29228441e-01 4.40349473e-01 -1.79601639 0.56257519 263.75 -1.23409690e-01 -4.06272108e-01 4.24602140e-01 -1.86570015 0.56548518 264.00 -1.64631947e-01 -4.41375298e-01 4.71079432e-01 -1.92781035 0.67517983 264.25 -1.63250407e-01 -4.41169084e-01 4.70404992e-01 -1.92521183 0.71036110 264.50 -1.54925513e-01 -3.67915246e-01 3.99203636e-01 -1.96935070 0.57306056 264.75 -1.62178743e-01 -3.81975661e-01 4.14978735e-01 -1.97231010 0.63642389 265.00 -1.17080234e-01 -3.81231260e-01 3.98804532e-01 -1.86876395 0.67265141 265.25 -1.19348875e-01 -3.73469692e-01 3.92076223e-01 -1.88010714 0.66423026 265.50 -1.71617865e-01 -3.68437992e-01 4.06447101e-01 -2.00671034 0.64565201 265.75 -1.61995856e-01 -3.52605059e-01 3.88037350e-01 -2.00146103 0.65233988 266.00 -1.04455315e-01 -3.50828144e-01 3.66048221e-01 -1.86017777 0.61176740 266.25 -1.07165004e-01 -3.40567766e-01 3.57030449e-01 -1.87565302 0.55672967 266.50 -5.24610023e-02 -3.21054813e-01 3.25312695e-01 -1.73276691 0.58572052 266.75 -6.34686132e-02 -3.11039457e-01 3.17448908e-01 -1.77208619 0.50749721 267.00 -9.71300386e-02 -2.80530687e-01 2.96869855e-01 -1.90411468 0.50713476 267.25 -8.52477581e-02 -2.87159771e-01 2.99546181e-01 -1.85937473 0.51746162 267.50 -1.20653626e-01 -3.23151673e-01 3.44941011e-01 -1.92813308 0.53532341 267.75 -1.22061025e-01 -3.01678555e-01 3.25436391e-01 -1.95526728 0.50429632 268.00 -9.68067118e-02 -2.61326046e-01 2.78680537e-01 -1.92556688 0.43355214 268.25 -1.71950732e-03 -2.39498651e-01 2.39504823e-01 -1.57797582 0.29139545 268.50 9.56794338e-02 -2.37661762e-01 2.56198492e-01 -1.18806214 0.42427895 268.75 1.02096260e-01 -2.63007008e-01 2.82128220e-01 -1.20051368 0.50122788 269.00 8.17406148e-02 -3.15437020e-01 3.25855861e-01 -1.31723914 0.58561389 269.25 1.42601355e-01 -3.61308852e-01 3.88431761e-01 -1.19488461 0.56273910 269.50 1.63746653e-01 -4.33951024e-01 4.63817268e-01 -1.20997659 0.71421417 269.75 1.20933897e-01 -3.99706656e-01 4.17600788e-01 -1.27699566 0.63198933 270.00 7.73067637e-02 -4.16752657e-01 4.23862139e-01 -1.38738313 0.65581181 270.25 1.39548708e-01 -4.77879279e-01 4.97837772e-01 -1.28667970 0.68145126 270.50 1.79281726e-01 -5.46089163e-01 5.74765440e-01 -1.25358151 0.73192693 270.75 1.59167708e-01 -5.81178638e-01 6.02580259e-01 -1.30348047 0.66942484 271.00 1.50429801e-01 -6.20844563e-01 6.38809123e-01 -1.33307902 0.67820839 271.25 1.76793781e-01 -7.20063432e-01 7.41449518e-01 -1.33003357 0.66496940 271.50 1.72588202e-01 -9.11758043e-01 9.27949038e-01 -1.38371812 0.78837055 271.75 9.64503900e-02 -1.00027408e+00 1.00491338e+00 -1.47466954 0.76441305 272.00 1.05299340e-02 -1.21602130e+00 1.21606689e+00 -1.56213721 0.78141124 272.25 -2.74650639e-01 -1.21985522e+00 1.25039184e+00 -1.79225372 0.64931734 272.50 -8.42401337e-01 -1.36010492e+00 1.59985169e+00 -2.12533322 0.68372552 272.75 -1.54624367e+00 -1.23726354e+00 1.98032587e+00 -2.46674580 0.73685563 273.00 -1.77904555e+00 -8.84744060e-01 1.98690088e+00 -2.68009624 0.67732996 273.25 -1.45262336e+00 -1.86719695e-01 1.46457464e+00 -3.01375400 0.49553096 273.50 -1.36643814e+00 2.59218038e-01 1.39080811e+00 2.95411693 0.48477172 273.75 -5.32224140e-01 7.25273601e-01 8.99602318e-01 2.20386503 0.21778286 274.00 5.15101756e-03 7.56793634e-01 7.56811163e-01 1.56399006 0.16263988 274.25 4.65189752e-01 4.11534281e-01 6.21097392e-01 0.72427444 0.12998252 274.50 6.99980840e-01 3.65250998e-01 7.89545102e-01 0.48093624 0.29600511 274.75 7.52996327e-01 4.19669079e-02 7.54164895e-01 0.05567562 0.30270936 275.00 8.07882764e-01 -1.70108505e-01 8.25597640e-01 -0.20752932 0.42205086 275.25 6.85146922e-01 -1.11064129e-01 6.94090445e-01 -0.16070475 0.43275725 275.50 7.63458599e-01 -2.01563148e-01 7.89618095e-01 -0.25812346 0.46967770 275.75 6.50339663e-01 -5.40192185e-01 8.45428455e-01 -0.69314124 0.50754241 276.00 5.80629375e-01 -6.20785558e-01 8.50003047e-01 -0.81880980 0.48702239 276.25 4.90605850e-01 -9.24251536e-01 1.04639142e+00 -1.08280231 0.48094437 276.50 3.10041666e-01 -9.51255316e-01 1.00050613e+00 -1.25572443 0.46269474 276.75 1.12384974e-01 -9.81045826e-01 9.87462048e-01 -1.45673724 0.43024358 277.00 -2.30753683e-01 -9.56120594e-01 9.83571986e-01 -1.80761144 0.39861606 277.25 -7.94334587e-01 -4.48020604e-01 9.11970338e-01 -2.62804928 0.34828808 277.50 -6.72607658e-01 -3.23362000e-01 7.46300238e-01 -2.69345621 0.32987401 277.75 -6.77478500e-01 -2.14991010e-01 7.10772997e-01 -2.83430451 0.32841692 278.00 -5.92813276e-01 -8.18110530e-02 5.98431808e-01 -3.00445413 0.32053414 278.25 -5.36143133e-01 -1.86496836e-02 5.36467398e-01 -3.10682178 0.44044283 278.50 -4.20818056e-01 -4.66891852e-02 4.23400185e-01 -3.03109594 0.34443314 278.75 -3.73633560e-01 -1.08249190e-01 3.88998617e-01 -2.85959334 0.49533011 279.00 -3.53411871e-01 -1.12712286e-01 3.70950145e-01 -2.83286412 0.52469840 279.25 -3.91394646e-01 -1.05949536e-01 4.05481286e-01 -2.87723086 0.67239504 279.50 -3.59547269e-01 -7.67062066e-02 3.67638520e-01 -2.93140265 0.59131123 279.75 -3.07077399e-01 -1.33581397e-01 3.34873885e-01 -2.73127503 0.58810853 280.00 -3.01286234e-01 -1.56676497e-01 3.39589339e-01 -2.66205336 0.56214415 280.25 -3.17137341e-01 -1.56891148e-01 3.53823296e-01 -2.68218565 0.65733771 280.50 -3.03173461e-01 -1.31028876e-01 3.30276723e-01 -2.73364687 0.58371666 280.75 -3.22099290e-01 -1.04794225e-01 3.38717851e-01 -2.82704641 0.72714974 281.00 -3.26150450e-01 -1.24304945e-01 3.49035579e-01 -2.77746068 0.68147293 281.25 -3.43252063e-01 -1.18644579e-01 3.63178351e-01 -2.80879965 0.77725803 281.50 -3.37835661e-01 -9.00886802e-02 3.49641107e-01 -2.88099255 0.68642097 281.75 -3.27262861e-01 -3.73948146e-02 3.29392399e-01 -3.02782072 0.69874790 282.00 -2.65513348e-01 -5.15081736e-02 2.70463361e-01 -2.94997806 0.60899866 282.25 -2.30556545e-01 -4.72671090e-02 2.35351865e-01 -2.93938150 0.62312689 282.50 -2.07850235e-01 -4.06593062e-02 2.11789753e-01 -2.94841381 0.53474804 282.75 -1.89666466e-01 -4.31027757e-02 1.94502487e-01 -2.91813229 0.54483088 283.00 -1.97040437e-01 -7.71680782e-02 2.11612491e-01 -2.76831757 0.53853774 283.25 -2.05903455e-01 -1.00887270e-01 2.29291243e-01 -2.68599824 0.61822392 283.50 -1.70837774e-01 -1.08541616e-01 2.02402637e-01 -2.57558592 0.54674678 283.75 -1.95816934e-01 -1.01462891e-01 2.20542490e-01 -2.66352930 0.64207270 284.00 -2.07454980e-01 -1.10565001e-01 2.35079110e-01 -2.65192680 0.69681883 284.25 -2.05420342e-01 -1.19020610e-01 2.37409820e-01 -2.61645771 0.73861093 284.50 -2.20529212e-01 -1.15864920e-01 2.49114056e-01 -2.65783614 0.64824829 284.75 -2.17967290e-01 -1.16836280e-01 2.47306400e-01 -2.64954079 0.61135350 285.00 -2.13351918e-01 -1.10826038e-01 2.40419324e-01 -2.66250498 0.67730469 285.25 -2.06983844e-01 -9.65428511e-02 2.28391843e-01 -2.70516233 0.70698241 285.50 -2.29064965e-01 -8.40208055e-02 2.43988225e-01 -2.79003119 0.78741602 285.75 -2.22791765e-01 -9.06384401e-02 2.40523382e-01 -2.75521199 0.81693754 286.00 -2.06611536e-01 -7.66556462e-02 2.20373353e-01 -2.78632167 0.79501573 286.25 -1.99975986e-01 -7.26890558e-02 2.12777099e-01 -2.79295188 0.80010841 286.50 -2.01130737e-01 -6.85366938e-02 2.12487298e-01 -2.81317580 0.76900810 286.75 -1.84283713e-01 -7.96752246e-02 2.00770088e-01 -2.73351226 0.74837511 287.00 -1.60141653e-01 -4.97520113e-02 1.67692015e-01 -2.84037126 0.79912952 287.25 -1.58127617e-01 -5.31659976e-02 1.66826157e-01 -2.81724448 0.81223189 287.50 -1.35210170e-01 -6.36347774e-02 1.49436190e-01 -2.70171094 0.77083037 287.75 -1.33346485e-01 -7.17704899e-02 1.51434106e-01 -2.64783422 0.73970465 288.00 -1.40705836e-01 -6.25788250e-02 1.53994291e-01 -2.72311377 0.73841942 288.25 -1.40485116e-01 -6.58899820e-02 1.55169448e-01 -2.70303678 0.75428609 288.50 -1.28589949e-01 -6.92317504e-02 1.46042494e-01 -2.64770549 0.77711639 288.75 -1.19958310e-01 -7.18391026e-02 1.39824364e-01 -2.60200648 0.70711489 289.00 -1.18922738e-01 -7.18907165e-02 1.38963638e-01 -2.59785906 0.68598175 289.25 -1.20732925e-01 -8.12681502e-02 1.45536770e-01 -2.54913335 0.63618584 289.50 -1.31903799e-01 -6.71875750e-02 1.48029667e-01 -2.67047876 0.69507034 289.75 -1.13308143e-01 -6.42477613e-02 1.30255557e-01 -2.62577772 0.60703131 290.00 -1.02863545e-01 -7.00654598e-02 1.24459140e-01 -2.54363033 0.70920365 290.25 -8.84456614e-02 -7.94199168e-02 1.18870342e-01 -2.40991046 0.65898789 290.50 -7.96452656e-02 -9.35796940e-02 1.22884204e-01 -2.27592610 0.73201085 290.75 -8.54665323e-02 -1.00796922e-01 1.32153500e-01 -2.27407471 0.68811467 291.00 -9.42657161e-02 -1.10056678e-01 1.44908583e-01 -2.27906327 0.78659395 291.25 -9.02828403e-02 -1.13055673e-01 1.44680947e-01 -2.24466455 0.73288546 291.50 -7.94234845e-02 -1.22143143e-01 1.45695015e-01 -2.14734673 0.75432963 291.75 -8.26035643e-02 -1.22097071e-01 1.47414530e-01 -2.16560327 0.70772314 292.00 -9.05029917e-02 -1.27961311e-01 1.56731900e-01 -2.18638377 0.75729812 292.25 -1.11041765e-01 -1.34794264e-01 1.74641825e-01 -2.25987420 0.72567350 292.50 -1.21821997e-01 -1.17828536e-01 1.69482043e-01 -2.37285663 0.75286069 292.75 -1.14542280e-01 -1.15161463e-01 1.62425665e-01 -2.35349892 0.58613643 293.00 -8.08651427e-02 -1.08383684e-01 1.35226455e-01 -2.21179721 0.64213624 293.25 -8.07206725e-02 -1.07147926e-01 1.34151053e-01 -2.21644265 0.63209630 293.50 -7.81992849e-02 -1.08203111e-01 1.33502964e-01 -2.19660074 0.66232698 293.75 -7.62607246e-02 -1.10306898e-01 1.34101864e-01 -2.17569361 0.56420596 294.00 -7.17459909e-02 -1.11035787e-01 1.32198461e-01 -2.14446166 0.62394167 294.25 -4.92824018e-02 -1.22169894e-01 1.31735485e-01 -1.95422373 0.52203492 294.50 -4.36424584e-02 -1.23348844e-01 1.30841895e-01 -1.91086422 0.53748647 294.75 -5.76951065e-02 -1.45987748e-01 1.56974991e-01 -1.94716237 0.55918026 295.00 -4.51016202e-02 -1.66152875e-01 1.72165426e-01 -1.83585591 0.66486234 295.25 -3.45352684e-02 -1.82829217e-01 1.86062375e-01 -1.75749020 0.51602344 295.50 -2.80310747e-02 -1.81262440e-01 1.83417047e-01 -1.72422456 0.48786600 295.75 -4.90621291e-02 -2.04276161e-01 2.10085322e-01 -1.80650724 0.47399218 296.00 -7.56505235e-02 -2.24234166e-01 2.36651564e-01 -1.89617805 0.49389645 296.25 -1.59608646e-01 -2.41843064e-01 2.89763675e-01 -2.15414694 0.60285953 296.50 -1.69066556e-01 -2.29416915e-01 2.84983545e-01 -2.20588666 0.63930494 296.75 -1.38833712e-01 -2.18613761e-01 2.58972539e-01 -2.13659991 0.66157193 297.00 -1.22143810e-01 -2.15136173e-01 2.47391761e-01 -2.08716584 0.62059252 297.25 -1.77047596e-01 -2.04234474e-01 2.70291642e-01 -2.28501112 0.65719722 297.50 -1.82010370e-01 -2.04393905e-01 2.73687126e-01 -2.29833139 0.69407331 297.75 -1.92858828e-01 -2.49798328e-01 3.15584747e-01 -2.22826582 0.75069975 298.00 -1.87612276e-01 -2.32815401e-01 2.99000630e-01 -2.24908893 0.69695531 298.25 -1.96258744e-01 -2.18458209e-01 2.93669004e-01 -2.30271633 0.67760564 298.50 -1.98865749e-01 -2.11382572e-01 2.90224357e-01 -2.32569359 0.65127094 298.75 -2.09064217e-01 -1.71383783e-01 2.70333586e-01 -2.45491481 0.65151067 299.00 -2.17827097e-01 -1.77047378e-01 2.80703435e-01 -2.45910229 0.61235112 299.25 -2.72370378e-01 -2.21416656e-01 3.51014185e-01 -2.45902023 0.73798024 299.50 -2.74355873e-01 -2.24283523e-01 3.54364564e-01 -2.45627695 0.70941623 299.75 -2.88415203e-01 -2.05219930e-01 3.53975351e-01 -2.52316139 0.70867326 300.00 -3.13924111e-01 -1.96435619e-01 3.70317836e-01 -2.58245967 0.65917060 300.25 -3.24076669e-01 -1.38290150e-01 3.52349050e-01 -2.73826565 0.66881387 300.50 -3.12090778e-01 -1.32334892e-01 3.38988462e-01 -2.74054650 0.66339836 300.75 -2.80467060e-01 -1.07692667e-01 3.00432160e-01 -2.77497578 0.69015094 301.00 -2.94034370e-01 -9.01170985e-02 3.07534229e-01 -2.84419707 0.62206266 301.25 -2.73241988e-01 -1.06126211e-01 2.93127884e-01 -2.77112921 0.56789704 301.50 -2.80078034e-01 -1.41952690e-01 3.13997247e-01 -2.67249388 0.61394860 301.75 -3.03567396e-01 -1.46334102e-01 3.36996785e-01 -2.69240939 0.67009439 302.00 -3.29572048e-01 -1.38557077e-01 3.57513354e-01 -2.74361183 0.63085519 302.25 -3.31811811e-01 -1.26712508e-01 3.55183245e-01 -2.77680332 0.63293119 302.50 -3.42120390e-01 -9.20579664e-02 3.54289472e-01 -2.87873793 0.49436960 302.75 -3.26657411e-01 -6.05778140e-02 3.32226934e-01 -2.95822819 0.51989642 303.00 -3.59648125e-01 -6.76329321e-02 3.65952165e-01 -2.95571048 0.45584845 303.25 -4.02990815e-01 -5.40094782e-02 4.06593926e-01 -3.00836493 0.55694171 303.50 -4.21112204e-01 1.55466801e-02 4.21399084e-01 3.10469127 0.50113811 303.75 -4.11990354e-01 2.46440305e-02 4.12726762e-01 3.08184684 0.53971131 304.00 -3.76199904e-01 3.35580426e-02 3.77693672e-01 3.05262544 0.46129390 304.25 -3.98710926e-01 2.84390892e-02 3.99723885e-01 3.07038566 0.58468896 304.50 -3.95987141e-01 8.75955777e-02 4.05559861e-01 2.92389028 0.44595208 304.75 -4.18381295e-01 1.02376059e-01 4.30724698e-01 2.90161257 0.48901142 305.00 -2.79327204e-01 1.56338962e-01 3.20102418e-01 2.63133403 0.27271126 305.25 -2.72638011e-01 1.44965659e-01 3.08782330e-01 2.65289630 0.27157616 305.50 -2.70215909e-01 8.08723955e-02 2.82058472e-01 2.85078914 0.18189493 305.75 -2.52484214e-01 1.16906382e-01 2.78236196e-01 2.70796048 0.15657594 306.00 -1.14186796e-01 1.17789021e-01 1.64051449e-01 2.34066729 0.04194877 306.25 -5.28237851e-02 1.58029684e-01 1.66624528e-01 1.89338511 0.04900217 306.50 -1.49202755e-01 8.52282336e-02 1.71829317e-01 2.62260057 0.06140071 306.75 -1.84559218e-01 5.56916066e-02 1.92778785e-01 2.84852685 0.10714208 307.00 -1.23311553e-01 1.06293237e-01 1.62800465e-01 2.43017924 0.10649708 307.25 -6.80677782e-02 1.13156164e-01 1.32051277e-01 2.11234624 0.07400813 307.50 -1.64136360e-01 1.56722577e-01 2.26942087e-01 2.37929643 0.26773192 307.75 -1.29356659e-01 1.30411625e-01 1.83685430e-01 2.35213333 0.21546348 308.00 -1.33275538e-01 1.69663372e-01 2.15749922e-01 2.23665114 0.32327761 308.25 -1.37710929e-01 1.96835025e-01 2.40225575e-01 2.18127133 0.39498984 308.50 -9.39039542e-02 2.16130561e-01 2.35648832e-01 1.98066738 0.44712776 308.75 -8.48809170e-02 2.18301490e-01 2.34222780e-01 1.94163148 0.43167327 309.00 -2.60918353e-03 2.40952029e-01 2.40966156e-01 1.58162455 0.47452766 309.25 -2.64265190e-02 2.64009384e-01 2.65328693e-01 1.67056091 0.51037207 309.50 -4.62137181e-02 2.78569379e-01 2.82376710e-01 1.73519568 0.57921903 309.75 -1.54129440e-02 2.65703062e-01 2.66149724e-01 1.62873955 0.45960838 310.00 5.60307497e-02 2.48893327e-01 2.55122193e-01 1.34936811 0.44585562 310.25 3.33864750e-02 2.36460269e-01 2.38805602e-01 1.43053076 0.36760238 310.50 1.46629014e-02 2.75559370e-01 2.75949211e-01 1.51763506 0.52840665 310.75 1.45466372e-02 3.36276017e-01 3.36590500e-01 1.52756525 0.53485088 311.00 3.53030704e-02 3.73214721e-01 3.74880694e-01 1.47648510 0.56373829 311.25 8.26757859e-02 3.88659848e-01 3.97355965e-01 1.36120029 0.52613775 311.50 2.20123743e-01 4.25182130e-01 4.78784196e-01 1.09307629 0.59251510 311.75 2.58353520e-01 4.75033817e-01 5.40743626e-01 1.07267670 0.56267299 312.00 3.16382227e-01 5.44646895e-01 6.29871379e-01 1.04454367 0.64633367 312.25 3.62204741e-01 5.93290176e-01 6.95115463e-01 1.02269065 0.56451805 312.50 3.63150920e-01 6.34521560e-01 7.31092471e-01 1.05097664 0.43502637 312.75 4.28863602e-01 4.51425537e-01 6.22662834e-01 0.81102269 0.18085418 313.00 7.56633682e-01 -2.77899409e-03 7.56638785e-01 -0.00367282 0.18131740 313.25 1.36025454e-01 -1.83375893e-01 2.28319167e-01 -0.93257370 0.01776352 313.50 -1.48538034e-01 -5.69340546e-01 5.88397998e-01 -1.82600242 0.11316434 313.75 -6.06806281e-01 -7.04315414e-01 9.29663415e-01 -2.28196038 0.38079875 314.00 -7.79697863e-01 -7.96594506e-01 1.11467106e+00 -2.34547567 0.59713794 314.25 -6.56417291e-01 -6.77083242e-01 9.43040496e-01 -2.34069821 0.73369415 314.50 -5.93166406e-01 -6.49381372e-01 8.79512679e-01 -2.31098363 0.82405059 314.75 -4.28481512e-01 -5.64180055e-01 7.08445863e-01 -2.22033488 0.81944873 315.00 -3.95771026e-01 -5.46802678e-01 6.75002129e-01 -2.19731180 0.86602925 315.25 -4.06604654e-01 -5.17643234e-01 6.58241492e-01 -2.23662815 0.81883559 315.50 -4.24607337e-01 -4.94211745e-01 6.51564763e-01 -2.28058470 0.81796769 315.75 -4.78623183e-01 -4.02965487e-01 6.25668710e-01 -2.44180445 0.78562000 316.00 -5.12808436e-01 -3.39591394e-01 6.15056751e-01 -2.55667566 0.79656882 316.25 -4.43050864e-01 -2.50568604e-01 5.08997735e-01 -2.62688727 0.80402866 316.50 -4.39102255e-01 -2.20990873e-01 4.91576806e-01 -2.67532541 0.84685114 316.75 -3.83461656e-01 -1.69886263e-01 4.19409328e-01 -2.72454736 0.80683522 317.00 -3.54313513e-01 -1.40838017e-01 3.81278655e-01 -2.76324722 0.78436861 317.25 -3.75205576e-01 -1.12655268e-01 3.91753026e-01 -2.84990702 0.82104353 317.50 -3.63388911e-01 -9.91797060e-02 3.76680388e-01 -2.87515200 0.82853896 317.75 -3.34600677e-01 -1.14898827e-01 3.53778679e-01 -2.81081776 0.76532373 318.00 -3.42808462e-01 -9.33754323e-02 3.55297921e-01 -2.87566043 0.77168334 318.25 -2.83888268e-01 -6.66419310e-02 2.91605376e-01 -2.91102043 0.69433078 318.50 -2.65051514e-01 -5.11670421e-02 2.69945126e-01 -2.95089282 0.66476546 318.75 -2.23147464e-01 -6.54854682e-02 2.32557815e-01 -2.85614408 0.63930502 319.00 -2.20405665e-01 -7.25603976e-02 2.32042385e-01 -2.82355502 0.57895905 319.25 -2.53613149e-01 -1.83837883e-02 2.54278574e-01 -3.06923169 0.71134071 319.50 -2.41291226e-01 -1.79405465e-02 2.41957266e-01 -3.06737696 0.62210666 319.75 -2.09051766e-01 -4.45563272e-03 2.09099243e-01 -3.12028234 0.56415984 320.00 -2.02983033e-01 -1.72330651e-02 2.03713255e-01 -3.05689671 0.56316943 320.25 -1.91505842e-01 -2.56806273e-02 1.93220036e-01 -3.00828949 0.70143662 320.50 -1.88275766e-01 -1.73701988e-02 1.89075350e-01 -3.04959374 0.64117498 320.75 -1.81418323e-01 -4.47072511e-02 1.86845782e-01 -2.89997507 0.66293259 321.00 -1.77583490e-01 -3.78567803e-02 1.81573764e-01 -2.93155925 0.61230366 321.25 -1.69604098e-01 -2.98244450e-02 1.72206410e-01 -2.96752486 0.67612592 321.50 -1.60880496e-01 -2.17218381e-02 1.62340298e-01 -3.00738579 0.55063422 321.75 -1.55230984e-01 -2.90661887e-02 1.57928787e-01 -2.95649128 0.59565037 322.00 -1.40166594e-01 -1.76582234e-02 1.41274510e-01 -3.01627260 0.47900014 322.25 -1.15045730e-01 -1.24925739e-02 1.15722013e-01 -3.03342856 0.47247944 322.50 -1.20410788e-01 -7.06594543e-03 1.20617932e-01 -3.08297788 0.45045787 322.75 -1.17651408e-01 -4.08115097e-03 1.17722171e-01 -3.10691806 0.50084790 323.00 -9.98752747e-02 -1.25366477e-02 1.00659019e-01 -3.01672270 0.38614871 323.25 -1.06773383e-01 -2.12529040e-02 1.08867999e-01 -2.94511377 0.48810003 323.50 -1.09152465e-01 -3.63093581e-02 1.15033170e-01 -2.82045895 0.48974825 323.75 -1.09368802e-01 -2.29069729e-02 1.11741954e-01 -2.93513011 0.53854588 324.00 -9.48189084e-02 -4.19319865e-02 1.03676983e-01 -2.72521707 0.43288508 324.25 -8.95267844e-02 -4.57959906e-02 1.00560021e-01 -2.66876051 0.47230145 324.50 -8.66781352e-02 -5.09959885e-02 1.00566843e-01 -2.60979273 0.42447566 324.75 -8.30949566e-02 -5.13071829e-02 9.76585830e-02 -2.58843922 0.52477908 325.00 -9.26829259e-02 -5.48563969e-02 1.07700274e-01 -2.60717131 0.49489447 325.25 -1.00797413e-01 -5.71760293e-02 1.15884498e-01 -2.62561199 0.62779402 325.50 -9.34319122e-02 -3.96762217e-02 1.01507265e-01 -2.74001523 0.51184753 325.75 -9.08518438e-02 -3.75186233e-02 9.82939704e-02 -2.74995984 0.54761527 326.00 -1.16399102e-01 -3.22958981e-02 1.20796424e-01 -2.87094241 0.68625085 326.25 -1.13382987e-01 -3.82913385e-02 1.19674260e-01 -2.81590219 0.71246785 326.50 -9.70202884e-02 -1.80859645e-02 9.86916332e-02 -2.95729378 0.49605113 326.75 -8.25490625e-02 -1.20566905e-02 8.34248854e-02 -2.99656326 0.45007223 327.00 -7.31761729e-02 -1.74903414e-02 7.52373865e-02 -2.90697745 0.41913986 327.25 -6.28640454e-02 -2.59547083e-02 6.80112865e-02 -2.75004051 0.34767617 327.50 -6.24496676e-02 -3.72504939e-02 7.27156124e-02 -2.60375931 0.30910051 327.75 -5.56590984e-02 -5.34964990e-02 7.71998098e-02 -2.37600398 0.30562307 328.00 -6.92319315e-02 -8.28092656e-02 1.07937180e-01 -2.26713037 0.48093489 328.25 -7.19647036e-02 -8.22215244e-02 1.09267093e-01 -2.28977007 0.50115243 328.50 -6.56378074e-02 -5.50640923e-02 8.56759945e-02 -2.44357332 0.36123428 328.75 -6.95823707e-02 -5.04510642e-02 8.59477527e-02 -2.51424824 0.33094849 329.00 -5.71376764e-02 -9.21683293e-02 1.08442220e-01 -2.12573964 0.45682358 329.25 -6.07503729e-02 -1.01733734e-01 1.18492027e-01 -2.10911814 0.53402571 329.50 -8.16287287e-02 -1.32199061e-01 1.55370013e-01 -2.12396124 0.69112494 329.75 -9.38678778e-02 -1.37513840e-01 1.66496951e-01 -2.16975335 0.68685682 330.00 -1.18578714e-01 -1.40859226e-01 1.84125590e-01 -2.27052476 0.74564527 330.25 -1.38727497e-01 -1.29408776e-01 1.89715444e-01 -2.39093418 0.72546711 330.50 -1.62772138e-01 -8.89233695e-02 1.85478124e-01 -2.64159007 0.76616189 330.75 -1.60614320e-01 -7.50317572e-02 1.77275843e-01 -2.70456470 0.72622947 331.00 -1.49603265e-01 -4.66566475e-02 1.56709858e-01 -2.83928259 0.72872046 331.25 -1.44168601e-01 -4.00929775e-02 1.49639675e-01 -2.87034869 0.68791750 331.50 -1.56008448e-01 -3.17980892e-02 1.59216062e-01 -2.94052398 0.78346008 331.75 -1.46111420e-01 -3.63271047e-02 1.50559641e-01 -2.89790754 0.72083451 332.00 -1.36610381e-01 -4.94701302e-02 1.45291741e-01 -2.79415653 0.79865692 332.25 -1.30954388e-01 -3.39127004e-02 1.35274251e-01 -2.88819361 0.71310440 332.50 -1.12450739e-01 -3.43755847e-02 1.17587625e-01 -2.84491967 0.72195590 332.75 -1.14708702e-01 -2.92779297e-02 1.18386163e-01 -2.89169095 0.65719818 333.00 -1.02817626e-01 -2.23021256e-02 1.05208598e-01 -2.92799203 0.61508017 333.25 -1.10278307e-01 -4.01257537e-02 1.17351528e-01 -2.79262504 0.55474391 333.50 -1.40713674e-01 -2.96170792e-02 1.43796764e-01 -2.93414306 0.68221784 333.75 -1.26856860e-01 8.93479248e-04 1.26860006e-01 3.13454956 0.59273062 334.00 -9.25102347e-02 1.72717638e-02 9.41087527e-02 2.95701657 0.51931979 334.25 -4.91309177e-02 1.56577448e-03 4.91558615e-02 3.10973400 0.18511910 334.50 -1.52803903e-02 -3.71041054e-02 4.01273593e-02 -1.96145474 0.15910966 334.75 -1.11630777e-02 -6.98517785e-02 7.07381458e-02 -1.72926723 0.30349642 335.00 -2.51168669e-02 -1.00191099e-01 1.03291400e-01 -1.81642392 0.50021585 335.25 -5.93653155e-02 -1.15034260e-01 1.29449301e-01 -2.04721428 0.47273012 335.50 -9.69299963e-02 -1.33513937e-01 1.64989077e-01 -2.19875417 0.57527824 335.75 -1.04570879e-01 -1.28350542e-01 1.65556426e-01 -2.25445392 0.59304832 336.00 -1.03081576e-01 -1.31831585e-01 1.67348075e-01 -2.23441441 0.66317415 336.25 -1.24014427e-01 -1.59473676e-01 2.02018394e-01 -2.23175879 0.72733833 336.50 -1.45593856e-01 -1.81444788e-01 2.32636588e-01 -2.24700755 0.78395307 336.75 -2.12498962e-01 -1.88434809e-01 2.84013180e-01 -2.41614284 0.80696589 337.00 -2.67492568e-01 -1.81756316e-01 3.23400112e-01 -2.54477047 0.80778512 337.25 -3.82395973e-01 -8.17016395e-02 3.91026646e-01 -2.93110035 0.83012453 337.50 -3.80767687e-01 -1.49609347e-02 3.81061493e-01 -3.10232135 0.84825504 337.75 -3.63691915e-01 8.75258750e-02 3.74075644e-01 2.90542429 0.89008008 338.00 -3.73848711e-01 1.26017591e-01 3.94516529e-01 2.81647230 0.91263244 338.25 -3.57002919e-01 1.70269799e-01 3.95528619e-01 2.69656075 0.87887737 338.50 -3.47483457e-01 2.25720523e-01 4.14360359e-01 2.56550825 0.87354963 338.75 -3.58362635e-01 2.90899816e-01 4.61569585e-01 2.45972980 0.85148297 339.00 -2.73064974e-01 3.56006371e-01 4.48670276e-01 2.22510326 0.77052695 339.25 -9.51936337e-02 3.70829016e-01 3.82852435e-01 1.82207548 0.81142176 339.50 -5.87962926e-02 3.65543388e-01 3.70241775e-01 1.73027663 0.81215227 339.75 -3.59340617e-02 3.32416153e-01 3.34352741e-01 1.67847781 0.84818931 340.00 -1.76732582e-02 3.37220470e-01 3.37683268e-01 1.62315704 0.86111908 340.25 4.68501488e-02 3.53774841e-01 3.56863524e-01 1.43913316 0.86126168 340.50 7.28453576e-02 3.58687280e-01 3.66009578e-01 1.37043257 0.84771943 340.75 5.95847198e-02 3.62824017e-01 3.67684112e-01 1.40802441 0.86385711 341.00 7.79287788e-02 3.89876555e-01 3.97588510e-01 1.37351553 0.86326203 341.25 1.36701543e-01 4.22568000e-01 4.44129515e-01 1.25792002 0.87877368 341.50 2.25978119e-01 4.47855577e-01 5.01638044e-01 1.10349294 0.83965384 341.75 3.40455998e-01 4.64280264e-01 5.75731231e-01 0.93807018 0.86620771 342.00 4.17252732e-01 4.05768462e-01 5.82020521e-01 0.77144527 0.81281771 342.25 5.44158713e-01 3.28448876e-01 6.35600007e-01 0.54305519 0.85072455 342.50 6.01674387e-01 2.31331228e-01 6.44613222e-01 0.36705511 0.84700101 342.75 6.48517524e-01 1.62565616e-01 6.68582500e-01 0.24561166 0.88857987 343.00 6.29280378e-01 3.70732845e-02 6.30371496e-01 0.05884576 0.84144619 343.25 6.02478447e-01 -4.95163263e-02 6.04509839e-01 -0.08200341 0.90477077 343.50 6.01663885e-01 -5.82433647e-02 6.04476402e-01 -0.09650313 0.88907676 343.75 6.09080353e-01 -5.33480724e-02 6.11412213e-01 -0.08736495 0.92156226 344.00 6.50144874e-01 -5.71225345e-02 6.52649478e-01 -0.08763620 0.89518887 344.25 6.96107784e-01 -1.03361507e-01 7.03739759e-01 -0.14740788 0.90798420 344.50 7.85598343e-01 -1.26180527e-01 7.95667193e-01 -0.15925690 0.89013404 344.75 9.17280600e-01 -1.80752095e-01 9.34919793e-01 -0.19455947 0.91177829 345.00 9.95177897e-01 -2.91786370e-01 1.03707200e+00 -0.28520684 0.91251761 345.25 1.08727667e+00 -3.74249971e-01 1.14988416e+00 -0.33150615 0.91994125 345.50 1.11973901e+00 -6.95877408e-01 1.31835534e+00 -0.55605248 0.87952457 345.75 1.11614888e+00 -9.23591772e-01 1.44872705e+00 -0.69127437 0.91025172 346.00 9.29437741e-01 -1.28040265e+00 1.58217744e+00 -0.94290181 0.90042292 346.25 7.37631885e-01 -1.42768170e+00 1.60697723e+00 -1.09390648 0.92084367 346.50 3.65936133e-01 -1.57262297e+00 1.61463688e+00 -1.34217309 0.90997756 346.75 1.13913348e-01 -1.52660861e+00 1.53085274e+00 -1.49631579 0.92712289 347.00 -7.95028417e-02 -1.41156197e+00 1.41379911e+00 -1.62705948 0.93897722 347.25 -1.47712192e-01 -1.32924172e+00 1.33742381e+00 -1.68146742 0.94914822 347.50 -2.50544304e-01 -1.27358086e+00 1.29799101e+00 -1.76504020 0.94684185 347.75 -3.03343418e-01 -1.23524011e+00 1.27194157e+00 -1.81160546 0.94423310 348.00 -2.92190844e-01 -1.19598621e+00 1.23116144e+00 -1.81041214 0.89897100 348.25 -3.77906531e-01 -1.14496918e+00 1.20572292e+00 -1.88959642 0.92693458 348.50 -3.66209727e-01 -1.14710592e+00 1.20414350e+00 -1.87981575 0.94803160 348.75 -3.75785479e-01 -1.17091765e+00 1.22974097e+00 -1.88134489 0.95635396 349.00 -4.31560808e-01 -1.24487237e+00 1.31755530e+00 -1.90450213 0.95120488 349.25 -5.26406670e-01 -1.22489176e+00 1.33321559e+00 -1.97668988 0.93499353 349.50 -6.78596769e-01 -1.27766787e+00 1.44669581e+00 -2.05902999 0.94870334 349.75 -7.51492184e-01 -1.28175096e+00 1.48580821e+00 -2.10108231 0.95063675 350.00 -9.63907967e-01 -1.31809396e+00 1.63293915e+00 -2.20221463 0.93763385 350.25 -1.04986192e+00 -1.29768706e+00 1.66919195e+00 -2.25101644 0.94180982 350.50 -1.19341476e+00 -1.18137211e+00 1.67924949e+00 -2.36126549 0.95792803 350.75 -1.34287953e+00 -1.15780230e+00 1.77308533e+00 -2.43007051 0.95846372 351.00 -1.49373336e+00 -1.02275799e+00 1.81032408e+00 -2.54120969 0.95793544 351.25 -1.62330610e+00 -8.59867926e-01 1.83698000e+00 -2.65446702 0.94033447 351.50 -1.75804283e+00 -5.49027647e-01 1.84177794e+00 -2.83889473 0.96053431 351.75 -1.77369224e+00 -3.55055967e-01 1.80888057e+00 -2.94402497 0.94432647 352.00 -1.79618025e+00 -4.45389874e-02 1.79673237e+00 -3.11680123 0.94317390 352.25 -1.68407979e+00 2.32971443e-01 1.70011777e+00 3.00412759 0.90718661 352.50 -1.40048593e+00 5.73454871e-01 1.51334442e+00 2.75295052 0.91169494 352.75 -1.08326018e+00 5.66370273e-01 1.22238615e+00 2.65984152 0.87461614 353.00 -7.92852612e-01 4.69096097e-01 9.21230923e-01 2.60733095 0.86180304 353.25 -6.02512314e-01 3.58871962e-01 7.01291790e-01 2.60439558 0.76097761 353.50 -4.27484704e-01 2.00270163e-01 4.72071298e-01 2.70347339 0.71151034 353.75 -3.40712196e-01 4.74643620e-02 3.44002422e-01 3.00317424 0.46167241 354.00 -3.18500495e-01 -2.38135732e-01 3.97682276e-01 -2.49957944 0.49926597 354.25 -3.49940759e-01 -5.50344518e-01 6.52179135e-01 -2.13716530 0.57598575 354.50 -4.62430935e-01 -8.84136213e-01 9.97767113e-01 -2.05269878 0.76989998 354.75 -7.91748536e-01 -1.40473378e+00 1.61249581e+00 -2.08404292 0.80791738 355.00 -1.47101067e+00 -1.76651195e+00 2.29879030e+00 -2.26517281 0.87541444 355.25 -2.37416263e+00 -1.65971465e+00 2.89677423e+00 -2.53148864 0.85971892 355.50 -3.25977581e+00 -1.38026428e+00 3.53995308e+00 -2.74105844 0.87686260 355.75 -3.81925104e+00 6.60087946e-02 3.81982142e+00 3.12431120 0.73986548 356.00 -4.45969203e+00 1.98126004e+00 4.87998405e+00 2.72352287 0.80778730 356.25 -3.01243225e+00 3.70772997e+00 4.77723870e+00 2.25309690 0.76733409 356.50 -1.59546803e+00 4.51733221e+00 4.79080458e+00 1.91030851 0.82694950 356.75 4.48382231e-01 3.70740085e+00 3.73441665e+00 1.45043841 0.74902876 357.00 1.26979718e+00 3.18071111e+00 3.42480774e+00 1.19096426 0.83709455 357.25 1.16690790e+00 1.65576208e+00 2.02564116e+00 0.95688569 0.78314482 357.50 1.08898240e+00 1.21867304e+00 1.63433370e+00 0.84153928 0.87317677 357.75 7.25930529e-01 9.29246701e-01 1.17918386e+00 0.90762237 0.85308906 358.00 5.31880242e-01 1.04662574e+00 1.17401961e+00 1.10062162 0.84198267 358.25 9.81152745e-01 1.21970114e+00 1.56535350e+00 0.89336569 0.79480125 358.50 1.24679202e+00 7.84478881e-01 1.47305718e+00 0.56161231 0.75901941 358.75 8.86433341e-01 1.53800553e-01 8.99676986e-01 0.17179465 0.80576596 359.00 7.37106273e-01 7.04838759e-02 7.40468523e-01 0.09533255 0.88380816 359.25 5.49424928e-01 3.65568328e-02 5.50639768e-01 0.06643861 0.90982644 359.50 4.74488799e-01 4.31562391e-02 4.76447354e-01 0.09070356 0.91376300 359.75 3.54352000e-01 2.25769517e-02 3.55070498e-01 0.06362734 0.88169284 360.00 2.98260671e-01 2.79003619e-02 2.99562778e-01 0.09327213 0.85963708 360.25 2.27971909e-01 3.94812099e-02 2.31365420e-01 0.17148361 0.86668916 360.50 2.02882775e-01 2.23920234e-02 2.04114730e-01 0.10992437 0.84600595 360.75 1.54697195e-01 9.33180537e-03 1.54978401e-01 0.06025003 0.78170951 361.00 1.28236995e-01 -5.70636510e-04 1.28238265e-01 -0.00444983 0.70673983 361.25 9.29493414e-02 -3.31447443e-02 9.86820862e-02 -0.34253295 0.51461116 361.50 3.81542093e-02 -4.63577597e-02 6.00398665e-02 -0.88216468 0.18202290 361.75 -7.18907123e-02 -9.05837011e-03 7.24591512e-02 -3.01625124 0.29680598 362.00 -1.01139647e-01 3.15214662e-02 1.05937864e-01 2.83947068 0.46218513 362.25 -1.34461846e-01 6.66214517e-02 1.50061340e-01 2.68157775 0.76045206 362.50 -1.53648978e-01 1.02908881e-01 1.84927678e-01 2.55144734 0.79346601 362.75 -1.75440784e-01 1.66607281e-01 2.41945149e-01 2.38201408 0.88358056 363.00 -1.34949356e-01 2.00509370e-01 2.41692648e-01 2.16319322 0.87216462 363.25 -9.08873023e-02 2.29112843e-01 2.46481636e-01 1.94844800 0.92240669 363.50 -5.91141449e-02 2.25949122e-01 2.33554036e-01 1.82668674 0.91468359 363.75 -2.92495600e-02 2.01757500e-01 2.03866686e-01 1.71476713 0.90834382 364.00 -2.68945833e-02 1.64796689e-01 1.66976847e-01 1.73256875 0.84695021 364.25 -4.58106520e-02 1.34500868e-01 1.42088350e-01 1.89907027 0.85318606 364.50 -8.98873933e-02 1.43315399e-01 1.69171650e-01 2.13097598 0.81558420 364.75 -1.29707574e-01 1.67478839e-01 2.11832992e-01 2.22977608 0.91408064 365.00 -1.32405609e-01 1.98718679e-01 2.38789360e-01 2.15854279 0.91633560 365.25 -1.18027403e-01 2.09654618e-01 2.40594112e-01 2.08353602 0.90377470 365.50 -9.37348644e-02 2.25128218e-01 2.43862542e-01 1.96532793 0.82708623 365.75 -8.14724183e-02 2.65214625e-01 2.77446486e-01 1.86884025 0.87006292 366.00 -5.26668269e-02 2.93397071e-01 2.98086624e-01 1.74841169 0.87960160 366.25 -1.63256824e-02 3.03544776e-01 3.03983485e-01 1.62452800 0.89888205 366.50 6.22210884e-02 2.79122282e-01 2.85973272e-01 1.35146544 0.83763333 366.75 9.53704293e-02 2.26028237e-01 2.45324852e-01 1.17152010 0.88003833 367.00 1.00955159e-01 1.67825760e-01 1.95850529e-01 1.02923977 0.82385024 367.25 1.10424349e-01 1.16679725e-01 1.60647736e-01 0.81293530 0.75391741 367.50 7.21843671e-02 5.65540684e-02 9.17003027e-02 0.66457822 0.44553766 367.75 3.00934474e-02 2.35765751e-02 3.82291835e-02 0.66456489 0.15856825 368.00 -4.48969374e-02 1.57617027e-02 4.75832561e-02 2.80397018 0.20538920 368.25 -7.25916313e-02 2.43556949e-02 7.65685628e-02 2.81787848 0.46703561 368.50 -8.57565713e-02 4.27541362e-02 9.58233045e-02 2.67910387 0.59496718 368.75 -9.44047813e-02 3.67789475e-02 1.01316108e-01 2.77009444 0.58972576 369.00 -1.56490630e-01 2.65081226e-02 1.58719872e-01 2.97379434 0.60807160 369.25 -1.90984639e-01 4.07697462e-02 1.95287748e-01 2.93127808 0.67710628 369.50 -2.47213206e-01 9.91505764e-02 2.66355413e-01 2.76016150 0.82711411 369.75 -2.89477926e-01 1.12521125e-01 3.10577644e-01 2.77086228 0.84762767 370.00 -3.16188298e-01 2.64627071e-01 4.12313627e-01 2.44473625 0.85746353 370.25 -2.58671053e-01 3.19064324e-01 4.10746584e-01 2.25203829 0.92130497 370.50 -1.87470776e-01 2.87820873e-01 3.43491116e-01 2.14811670 0.95772722 370.75 -1.83620772e-01 2.88281763e-01 3.41793743e-01 2.13794205 0.95622028 371.00 -2.07825282e-01 2.94950942e-01 3.60814919e-01 2.18460933 0.96042285 371.25 -2.07599551e-01 3.11709658e-01 3.74513664e-01 2.15833929 0.94534103 371.50 -1.89920018e-01 3.81065348e-01 4.25770376e-01 2.03315691 0.95703055 371.75 -1.64241320e-01 4.09773156e-01 4.41462626e-01 1.95200108 0.95425010 372.00 -1.36933047e-01 4.45991447e-01 4.66539420e-01 1.86869072 0.95215043 372.25 -1.03259426e-01 4.68672374e-01 4.79912808e-01 1.78765495 0.93920207 372.50 -6.17847591e-02 5.08581727e-01 5.12320924e-01 1.69168835 0.94738101 372.75 -1.58690408e-02 5.31521938e-01 5.31758777e-01 1.60064331 0.91489527 373.00 1.29915509e-01 5.42430221e-01 5.57771085e-01 1.33571812 0.86952354 373.25 2.61866155e-01 4.41732564e-01 5.13518784e-01 1.03567589 0.87110218 373.50 3.07804722e-01 3.29253036e-01 4.50723095e-01 0.81905322 0.93418409 373.75 2.97497209e-01 2.71592722e-01 4.02824026e-01 0.73991042 0.94148213 374.00 2.89425093e-01 2.19595550e-01 3.63303028e-01 0.64906504 0.94234423 374.25 2.54561021e-01 1.66387474e-01 3.04115283e-01 0.57891940 0.94544883 374.50 2.33054373e-01 1.40332425e-01 2.72043251e-01 0.54199490 0.96023341 374.75 1.90162558e-01 9.03698051e-02 2.10543345e-01 0.44363106 0.90674108 375.00 1.48893586e-01 6.50168999e-02 1.62469989e-01 0.41171097 0.89836292 375.25 9.33585709e-02 5.97275165e-02 1.10829594e-01 0.56914623 0.62944869 375.50 3.37718429e-02 6.55664606e-02 7.37529534e-02 1.09515919 0.50397025 375.75 -1.68026234e-02 1.10485014e-01 1.11755387e-01 1.72172043 0.56155738 376.00 -6.04696962e-02 1.64799297e-01 1.75543136e-01 1.92247264 0.78855781 376.25 -6.08184181e-02 2.78029860e-01 2.84604081e-01 1.78615192 0.86090197 376.50 -3.75657389e-02 3.35836375e-01 3.37930844e-01 1.68219054 0.93914896 376.75 6.69615921e-02 3.66716281e-01 3.72779674e-01 1.39018824 0.90431514 377.00 1.72436608e-01 3.54574269e-01 3.94280733e-01 1.11815238 0.94359481 377.25 2.35532607e-01 2.81774787e-01 3.67250105e-01 0.87455134 0.94464403 377.50 2.50826775e-01 2.24607804e-01 3.36693832e-01 0.73030659 0.95642092 377.75 2.17696703e-01 1.73284749e-01 2.78243525e-01 0.67229202 0.95602538 378.00 1.97189963e-01 1.60813318e-01 2.54450005e-01 0.68413590 0.95905688 378.25 1.85201031e-01 1.37282927e-01 2.30534214e-01 0.63788683 0.95495579 378.50 1.80924683e-01 1.30337274e-01 2.22983286e-01 0.62428328 0.96601374 378.75 1.62158273e-01 1.26569753e-01 2.05706606e-01 0.66275710 0.94977022 379.00 1.50466288e-01 1.24396248e-01 1.95229430e-01 0.69083350 0.94699630 379.25 1.39681258e-01 1.33885478e-01 1.93484302e-01 0.76421535 0.93804279 379.50 1.39766166e-01 1.41308386e-01 1.98752714e-01 0.79088498 0.94535531 379.75 1.42510202e-01 1.45679952e-01 2.03793538e-01 0.79639654 0.92624531 380.00 1.38723384e-01 1.44682940e-01 2.00442836e-01 0.80642337 0.93002786 380.25 1.23340535e-01 1.38725526e-01 1.85627743e-01 0.84403740 0.94371112 380.50 1.21044216e-01 1.46307396e-01 1.89888274e-01 0.87961262 0.93735601 380.75 1.12471335e-01 1.55993300e-01 1.92311494e-01 0.94611430 0.91488234 381.00 1.11107316e-01 1.75176762e-01 2.07440916e-01 1.00556704 0.91677178 381.25 1.08330505e-01 2.04672708e-01 2.31573781e-01 1.08399493 0.92135521 381.50 1.27835207e-01 2.21233009e-01 2.55511026e-01 1.04683736 0.91519244 381.75 1.76458844e-01 2.68200846e-01 3.21044261e-01 0.98886279 0.91820483 382.00 2.34273974e-01 2.53935740e-01 3.45496245e-01 0.82564961 0.90940786 382.25 3.50441092e-01 2.18855846e-01 4.13166843e-01 0.55825074 0.94711393 382.50 3.76891446e-01 1.89869320e-01 4.22016019e-01 0.46666481 0.93649734 382.75 4.12287892e-01 7.99209501e-02 4.19962694e-01 0.19147269 0.92674492 383.00 3.80120730e-01 6.48893024e-04 3.80121284e-01 0.00170707 0.90623041 383.25 3.08690521e-01 -8.81105066e-02 3.21019157e-01 -0.27803972 0.94067069 383.50 2.59431312e-01 -1.11079052e-01 2.82211201e-01 -0.40454722 0.91078792 383.75 1.69833592e-01 -1.04490597e-01 1.99403445e-01 -0.55155938 0.88135998 384.00 1.29938000e-01 -8.44379549e-02 1.54963390e-01 -0.57625757 0.80573716 384.25 1.08612104e-01 -5.00766665e-02 1.19600425e-01 -0.43201304 0.80918529 384.50 9.05541161e-02 -2.42828315e-02 9.37534204e-02 -0.26199441 0.66039970 384.75 7.60027734e-02 2.06724717e-02 7.87640314e-02 0.26557154 0.65550934 385.00 8.37136675e-02 6.52300398e-02 1.06126982e-01 0.66193131 0.70977869 385.25 1.08648272e-01 9.34774378e-02 1.43326475e-01 0.71048220 0.88875459 385.50 1.46933746e-01 1.03221310e-01 1.79566602e-01 0.61240346 0.89823132 385.75 1.86968903e-01 9.87513556e-02 2.11445503e-01 0.48592877 0.94524355 386.00 2.00066769e-01 9.11295692e-02 2.19843832e-01 0.42741481 0.94842142 386.25 2.08410945e-01 8.10886896e-02 2.23630270e-01 0.37105795 0.95593925 386.50 2.15344940e-01 6.90043080e-02 2.26130577e-01 0.31009855 0.94688297 386.75 2.28351410e-01 6.24645131e-02 2.36740748e-01 0.26701352 0.95803904 387.00 2.47890161e-01 4.74395659e-02 2.52388677e-01 0.18908709 0.94196916 387.25 2.59009195e-01 2.03643955e-02 2.59808529e-01 0.07846280 0.95360697 387.50 2.66066981e-01 -1.45557659e-02 2.66464836e-01 -0.05465267 0.95506818 387.75 2.60534254e-01 -2.46731679e-02 2.61699948e-01 -0.09442060 0.96493867 388.00 2.46360662e-01 -3.11751151e-02 2.48325318e-01 -0.12587356 0.93264313 388.25 2.45520217e-01 -3.45202592e-02 2.47935123e-01 -0.13968482 0.93418605 388.50 2.50964297e-01 -5.49570658e-02 2.56911186e-01 -0.21558062 0.92948375 388.75 2.52651623e-01 -6.12694516e-02 2.59974592e-01 -0.23791284 0.94240392 389.00 2.66829302e-01 -7.85738277e-02 2.78157730e-01 -0.28637779 0.93972918 389.25 2.79634794e-01 -9.11548332e-02 2.94117020e-01 -0.31511635 0.95131123 389.50 2.69828575e-01 -1.51302255e-01 3.09353895e-01 -0.51104748 0.93742060 389.75 2.60029094e-01 -1.92025516e-01 3.23247473e-01 -0.63608553 0.94913471 390.00 2.11948911e-01 -2.28187237e-01 3.11434995e-01 -0.82227531 0.93791262 390.25 1.71957606e-01 -2.48500635e-01 3.02195275e-01 -0.96547285 0.92967137 390.50 1.07434921e-01 -2.54045338e-01 2.75828382e-01 -1.17070859 0.92187910 390.75 7.67615121e-02 -2.43897773e-01 2.55692106e-01 -1.26588277 0.89899329 391.00 3.33019032e-02 -2.03480448e-01 2.06187559e-01 -1.40857307 0.82170917 391.25 1.75872907e-02 -1.79449211e-01 1.80308991e-01 -1.47310126 0.79943686 391.50 2.39695106e-03 -1.41863210e-01 1.41883458e-01 -1.55390172 0.72695480 391.75 4.93705134e-03 -1.17370450e-01 1.17474240e-01 -1.52875727 0.63663532 392.00 1.39968526e-02 -9.23458592e-02 9.34005867e-02 -1.42037138 0.59237283 392.25 8.17185904e-03 -8.40298279e-02 8.44262474e-02 -1.47385167 0.53688603 392.50 1.41159244e-03 -7.61451836e-02 7.61582667e-02 -1.55226028 0.52564729 392.75 1.31528277e-02 -6.62639348e-02 6.75566868e-02 -1.37485167 0.41452577 393.00 2.53546845e-02 -4.22438451e-02 4.92686764e-02 -1.03023102 0.37304329 393.25 3.05817197e-02 -4.50450523e-02 5.44453700e-02 -0.97436261 0.38166943 393.50 4.67470834e-02 -3.89445372e-02 6.08437900e-02 -0.69459477 0.39696211 393.75 5.73249164e-02 -3.88893720e-02 6.92714176e-02 -0.59608353 0.44068629 394.00 7.03263251e-02 -5.43917956e-02 8.89059021e-02 -0.65832228 0.61000354 394.25 7.32432945e-02 -7.58045999e-02 1.05408337e-01 -0.80258092 0.70052611 394.50 4.90040254e-02 -1.01548091e-01 1.12753755e-01 -1.12118999 0.66929477 394.75 -4.30505074e-03 -9.34663900e-02 9.35654826e-02 -1.61682368 0.48273683 395.00 -5.82106885e-02 -5.69146491e-02 8.14110652e-02 -2.36745165 0.43656757 395.25 -5.94402926e-02 -9.64015928e-03 6.02169499e-02 -2.98081036 0.24951408 395.50 -5.50913655e-02 2.84596075e-02 6.20081270e-02 2.66476189 0.20331046 395.75 -1.42039467e-02 7.69003883e-02 7.82011625e-02 1.75344360 0.20601104 396.00 8.49409191e-02 1.01039187e-01 1.31999535e-01 0.87174204 0.52724881 396.25 1.53121887e-01 3.38672580e-02 1.56822522e-01 0.21767405 0.65490169 396.50 1.71645434e-01 1.09845642e-03 1.71648949e-01 0.00639948 0.79357906 396.75 1.65531583e-01 -2.76176945e-02 1.67819671e-01 -0.16531970 0.77593678 397.00 1.63626565e-01 -5.73206449e-02 1.73376207e-01 -0.33695435 0.76631125 397.25 1.29551170e-01 -8.73791091e-02 1.56264566e-01 -0.59338935 0.71022633 397.50 9.47225956e-02 -1.00617531e-01 1.38189209e-01 -0.81556681 0.73723471 397.75 4.18636985e-02 -8.83101671e-02 9.77305217e-02 -1.12812095 0.56700328 398.00 3.06060964e-02 -6.81955830e-02 7.47487169e-02 -1.14894176 0.57323255 398.25 2.38049268e-02 -4.15146887e-02 4.78554482e-02 -1.05015799 0.37034576 398.50 2.41421028e-02 -2.58726530e-02 3.53869369e-02 -0.81998516 0.30116125 398.75 5.16942734e-02 -8.60378023e-03 5.24053713e-02 -0.16492409 0.57367044 399.00 6.07493137e-02 -4.56562808e-03 6.09206375e-02 -0.07501420 0.73667866 399.25 6.43304480e-02 -7.08506598e-03 6.47194307e-02 -0.10969340 0.71420658 399.50 6.79687013e-02 -1.02403986e-02 6.87357994e-02 -0.14953873 0.71707799 399.75 7.74497107e-02 -1.07781873e-03 7.74572100e-02 -0.01391547 0.76516517 400.00 8.26627169e-02 -4.11125900e-03 8.27648912e-02 -0.04969440 0.79051358 400.25 8.36969261e-02 -1.87805749e-02 8.57781175e-02 -0.22073173 0.83155069 400.50 7.90627555e-02 -2.02519903e-02 8.16153320e-02 -0.25075925 0.82274107 400.75 7.33794543e-02 -2.17353109e-02 7.65308307e-02 -0.28797089 0.67054420 401.00 6.11756386e-02 -1.50984333e-02 6.30112803e-02 -0.24196904 0.56245664 401.25 4.79591605e-02 1.14133186e-02 4.92985285e-02 0.23363407 0.39474057 401.50 4.04355751e-02 2.26876804e-02 4.63655754e-02 0.51131177 0.33926748 401.75 6.91310951e-02 6.27185024e-02 9.33419458e-02 0.73680079 0.66083907 402.00 8.69445776e-02 7.24645192e-02 1.13183330e-01 0.69481093 0.72775324 402.25 1.33321754e-01 7.39806375e-02 1.52472374e-01 0.50659969 0.74599139 402.50 1.78233384e-01 5.81690165e-02 1.87485396e-01 0.31546538 0.76020005 402.75 2.16671425e-01 2.09179856e-02 2.17678820e-01 0.09624416 0.85994598 403.00 2.21874613e-01 -6.60823002e-03 2.21972999e-01 -0.02977482 0.85994568 403.25 2.02028267e-01 -5.27595542e-02 2.08803715e-01 -0.25544435 0.86303596 403.50 1.95795817e-01 -7.60264214e-02 2.10038136e-01 -0.37037480 0.84722000 403.75 2.00448809e-01 -1.10733581e-01 2.29001422e-01 -0.50470558 0.90729525 404.00 1.74092982e-01 -1.14544975e-01 2.08396060e-01 -0.58194568 0.85985013 404.25 1.38823644e-01 -1.22914372e-01 1.85418303e-01 -0.72468966 0.84599519 404.50 1.19541535e-01 -1.26303827e-01 1.73904673e-01 -0.81289751 0.75836967 404.75 8.59004281e-02 -1.35092665e-01 1.60090323e-01 -1.00442352 0.78109229 405.00 7.51978823e-02 -1.10847486e-01 1.33947328e-01 -0.97472108 0.69396706 405.25 6.85089979e-02 -8.83736213e-02 1.11818512e-01 -0.91134883 0.64961740 405.50 6.18527599e-02 -7.74867972e-02 9.91461933e-02 -0.89713185 0.52874284 405.75 5.28513887e-02 -6.48689315e-02 8.36734580e-02 -0.88713128 0.46282185 406.00 7.49602253e-02 -4.47524815e-02 8.73030353e-02 -0.53822277 0.43506076 406.25 7.49185631e-02 -3.01015179e-02 8.07396586e-02 -0.38204839 0.49665068 406.50 1.00356498e-01 -2.92992109e-02 1.04546021e-01 -0.28405641 0.56477719 406.75 1.16480443e-01 -3.91602212e-02 1.22887007e-01 -0.32432445 0.70880078 407.00 1.20607983e-01 -5.18383516e-02 1.31276427e-01 -0.40593654 0.66508093 407.25 1.27604724e-01 -6.63652200e-02 1.43830831e-01 -0.47958569 0.78567680 407.50 1.16646943e-01 -6.76142956e-02 1.34826564e-01 -0.52532118 0.69675144 407.75 1.11685794e-01 -5.70453652e-02 1.25410886e-01 -0.47222369 0.73375593 408.00 1.04102752e-01 -5.62775204e-02 1.18340789e-01 -0.49559451 0.63114647 408.25 1.11729025e-01 -5.88076866e-02 1.26260520e-01 -0.48449851 0.70053859 408.50 1.27125239e-01 -8.48293652e-02 1.52829472e-01 -0.58843382 0.77676817 408.75 1.28365469e-01 -9.43278859e-02 1.59296716e-01 -0.63372691 0.80739410 409.00 1.40518383e-01 -8.88032765e-02 1.66227068e-01 -0.56359511 0.72671390 409.25 1.37997590e-01 -1.00047168e-01 1.70448733e-01 -0.62730304 0.72629866 409.50 1.12112086e-01 -1.15992015e-01 1.61317288e-01 -0.80240599 0.63230567 409.75 1.07922555e-01 -1.30140883e-01 1.69067818e-01 -0.87845803 0.63668297 410.00 9.07958861e-02 -1.23835746e-01 1.53555152e-01 -0.93813674 0.54834150 410.25 7.57240468e-02 -1.15508250e-01 1.38116933e-01 -0.99051359 0.55958649 410.50 5.15286251e-02 -1.15169309e-01 1.26171189e-01 -1.15009309 0.54293210 410.75 5.92269108e-02 -1.16503747e-01 1.30694109e-01 -1.10047584 0.55602467 411.00 3.03004180e-02 -1.01968284e-01 1.06375026e-01 -1.28195137 0.35916891 411.25 4.08500462e-02 -1.06994605e-01 1.14527603e-01 -1.20608141 0.38604305 411.50 4.04833013e-02 -5.96455205e-02 7.20866548e-02 -0.97448750 0.19455664 411.75 4.79198832e-02 -6.47000033e-02 8.05133879e-02 -0.93330786 0.20583482 412.00 6.40416639e-02 -3.35663767e-02 7.23051614e-02 -0.48276743 0.13395463 412.25 7.80466789e-02 -1.77216828e-02 8.00333814e-02 -0.22327923 0.12159172 412.50 1.07445711e-01 -6.90317996e-02 1.27710494e-01 -0.57107110 0.27116767 412.75 1.39672354e-01 -5.86065530e-02 1.51469781e-01 -0.39728813 0.28534666 413.00 1.65041686e-01 -1.13237408e-01 2.00153612e-01 -0.60134557 0.29050458 413.25 1.98370150e-01 -1.58958546e-01 2.54201762e-01 -0.67554708 0.39770491 413.50 1.10397711e-01 -1.62702331e-01 1.96620709e-01 -0.97462851 0.36947076 413.75 1.22890986e-01 -1.36802377e-01 1.83894222e-01 -0.83891554 0.30547287 414.00 1.93987042e-01 -1.10898750e-01 2.23449111e-01 -0.51933656 0.44676677 414.25 2.61138082e-01 -8.75636314e-02 2.75427826e-01 -0.32353339 0.50226470 414.50 3.06626709e-01 -1.29118918e-01 3.32703522e-01 -0.39855828 0.56151253 414.75 3.67795742e-01 -2.72431549e-01 4.57703678e-01 -0.63753169 0.55207573 415.00 3.53299246e-01 -6.01065632e-01 6.97208901e-01 -1.03940453 0.64654030 415.25 1.58168442e-01 -7.42348953e-01 7.59012005e-01 -1.36087058 0.62753021 415.50 -1.83274888e-02 -9.02499356e-01 9.02685429e-01 -1.59110102 0.74968338 415.75 -1.49265403e-01 -8.84328801e-01 8.96837549e-01 -1.73800973 0.71736268 416.00 -3.44581300e-01 -8.82445385e-01 9.47336334e-01 -1.94307292 0.75947076 416.25 -5.89640567e-01 -8.24638934e-01 1.01375804e+00 -2.19153767 0.74845354 416.50 -7.64480420e-01 -7.27574971e-01 1.05536517e+00 -2.38092409 0.85327235 416.75 -7.96742134e-01 -5.72889362e-01 9.81325761e-01 -2.51820222 0.78441486 417.00 -8.86145086e-01 -5.57572611e-01 1.04696721e+00 -2.57997063 0.81301352 417.25 -9.15074596e-01 -5.29603552e-01 1.05728021e+00 -2.61694134 0.76021712 417.50 -1.07905612e+00 -5.29244474e-01 1.20185765e+00 -2.68559820 0.83127002 417.75 -1.23444275e+00 -5.03171896e-01 1.33305321e+00 -2.75454272 0.84175070 418.00 -1.29946328e+00 -4.95126047e-01 1.39059505e+00 -2.77755159 0.86475029 418.25 -1.47896925e+00 -5.58025188e-01 1.58074102e+00 -2.78080110 0.83448416 418.50 -1.67918553e+00 -6.33410442e-01 1.79467904e+00 -2.78088332 0.87174629 418.75 -2.09041776e+00 -7.66427024e-01 2.22648980e+00 -2.79017295 0.79281677 419.00 -2.60578749e+00 -9.36548672e-01 2.76898029e+00 -2.79655860 0.80842943 419.25 -2.69592938e+00 -1.35051670e+00 3.01528283e+00 -2.67718804 0.70379383 419.50 -3.53770009e+00 -1.19562257e+00 3.73427841e+00 -2.81567845 0.63198678 419.75 -3.56330927e+00 -1.18521133e+00 3.75524950e+00 -2.82048843 0.37693741 420.00 -2.31413876e+00 -1.29752442e+00 2.65307516e+00 -2.63057594 0.18960492 420.25 1.07489217e-01 -8.65570334e-01 8.72218972e-01 -1.44724573 0.01832055 420.50 1.18932316e+00 -1.18090553e+00 1.67601535e+00 -0.78184678 0.06066134 420.75 2.31896320e+00 -1.36182567e+00 2.68926746e+00 -0.53099641 0.21114075 421.00 3.25449101e+00 -1.13773478e+00 3.44762994e+00 -0.33630877 0.33136755 421.25 4.28397081e+00 -1.26919696e+00 4.46802718e+00 -0.28802804 0.57282923 421.50 4.12028776e+00 -1.08738587e+00 4.26135885e+00 -0.25802714 0.66766702 421.75 3.64459749e+00 -1.41440066e+00 3.90942708e+00 -0.37018973 0.77276253 422.00 3.36806289e+00 -1.35346142e+00 3.62983546e+00 -0.38210155 0.80449827 422.25 3.26483965e+00 -1.30349869e+00 3.51543551e+00 -0.37986269 0.84483393 422.50 3.20979486e+00 -1.33987447e+00 3.47822464e+00 -0.39544396 0.83337694 422.75 3.53422923e+00 -1.25179313e+00 3.74936825e+00 -0.34040380 0.80037325 423.00 3.66256737e+00 -1.11926453e+00 3.82977191e+00 -0.29658245 0.72995257 423.25 3.43562754e+00 -1.39856894e+00 3.70938428e+00 -0.38659331 0.60447539 423.50 2.41096313e+00 -2.27382169e+00 3.31406220e+00 -0.75613273 0.52956217 423.75 4.69304430e-01 -2.94358091e+00 2.98075749e+00 -1.41269380 0.54110331 424.00 1.21564515e-01 -2.93491093e+00 2.93742746e+00 -1.52939982 0.55650307 424.25 2.29110384e-02 -3.13973790e+00 3.13982149e+00 -1.56349934 0.69545164 424.50 -3.20277492e-01 -2.66837635e+00 2.68752860e+00 -1.69025197 0.64326009 424.75 -8.34436738e-01 -2.21405926e+00 2.36608180e+00 -1.93121502 0.76237123 425.00 -7.70316809e-01 -2.09958166e+00 2.23643268e+00 -1.92243852 0.80783074 425.25 -8.11812314e-01 -1.98403425e+00 2.14369568e+00 -1.95918496 0.90158126 425.50 -8.16663460e-01 -1.80263019e+00 1.97899339e+00 -1.99617538 0.89566886 425.75 -8.43472982e-01 -1.74338256e+00 1.93670581e+00 -2.02141154 0.91958618 426.00 -8.81947669e-01 -1.64952858e+00 1.87050160e+00 -2.06179101 0.91006804 426.25 -1.04208502e+00 -1.59116538e+00 1.90203798e+00 -2.15062203 0.93399140 426.50 -1.09988823e+00 -1.46527648e+00 1.83215427e+00 -2.21470389 0.92200821 426.75 -1.24928826e+00 -1.32185852e+00 1.81879936e+00 -2.32797712 0.92171891 427.00 -1.39341615e+00 -1.03177304e+00 1.73382934e+00 -2.50422325 0.89708455 427.25 -1.41557300e+00 -7.78903067e-01 1.61571560e+00 -2.63856619 0.92330929 427.50 -1.30841706e+00 -4.37978219e-01 1.37977539e+00 -2.81857753 0.86422846 427.75 -1.22893917e+00 -1.94292902e-01 1.24420304e+00 -2.98479240 0.88125559 428.00 -1.04644429e+00 -3.35547247e-02 1.04698213e+00 -3.10953817 0.81591409 428.25 -8.59508938e-01 1.18025699e-01 8.67574596e-01 3.00512852 0.81085163 428.50 -5.67354200e-01 2.67686757e-01 6.27333235e-01 2.70074543 0.71111795 428.75 -3.52427616e-01 2.55406963e-01 4.35244691e-01 2.51447616 0.66497688 429.00 -1.27185482e-01 6.47224513e-02 1.42706491e-01 2.67086441 0.24825013 429.25 -7.54057398e-02 -3.47468958e-02 8.30263354e-02 -2.70979459 0.16126150 429.50 -5.34744609e-02 -1.67808568e-01 1.76122780e-01 -1.87928642 0.40180341 429.75 -7.18480039e-02 -2.05259995e-01 2.17471380e-01 -1.90750155 0.56937280 430.00 -1.33400951e-01 -2.22190782e-01 2.59161258e-01 -2.11150197 0.68446449 430.25 -1.38026706e-01 -2.24648145e-01 2.63662968e-01 -2.12174616 0.77136748 430.50 -1.03496220e-01 -2.15640802e-01 2.39191185e-01 -2.01827346 0.67800745 430.75 -8.42189824e-02 -1.89764627e-01 2.07613706e-01 -1.98848873 0.64791335 431.00 -3.38656069e-02 -2.38596685e-01 2.40988086e-01 -1.71179115 0.68364328 431.25 1.16100996e-02 -2.61298681e-01 2.61556486e-01 -1.52639324 0.72986689 431.50 5.26481782e-02 -3.90845421e-01 3.94375422e-01 -1.43689897 0.81668390 431.75 2.93848486e-02 -4.69415124e-01 4.70333954e-01 -1.50827905 0.85523877 432.00 -9.00362183e-02 -5.63475970e-01 5.70623948e-01 -1.72924404 0.86790343 432.25 -1.88000911e-01 -5.89297884e-01 6.18559891e-01 -1.87961482 0.87663025 432.50 -3.36280992e-01 -4.77054391e-01 5.83665827e-01 -2.18481081 0.88866788 432.75 -3.68069470e-01 -3.86101976e-01 5.33432161e-01 -2.33228869 0.88737849 433.00 -3.70590578e-01 -2.38756797e-01 4.40842584e-01 -2.56926296 0.87581521 433.25 -3.67463748e-01 -1.90729073e-01 4.14013509e-01 -2.66282785 0.84826779 433.50 -3.22830077e-01 -9.96510840e-02 3.37860322e-01 -2.84219200 0.69978704 433.75 -2.99863317e-01 -7.61965052e-02 3.09392819e-01 -2.89275503 0.65460250 434.00 -2.02801021e-01 -7.09847376e-03 2.02925214e-01 -3.10660478 0.41598845 434.25 -1.64133738e-01 2.98368701e-02 1.66823628e-01 2.96177234 0.26032015 434.50 -1.31469214e-01 2.78943120e-02 1.34395859e-01 2.93251947 0.11990010 434.75 -1.16447838e-01 1.37792695e-03 1.16455990e-01 3.12976021 0.09239225 435.00 -4.15607767e-02 -5.46892888e-02 6.86892748e-02 -2.22063104 0.03317229 435.25 -1.97266744e-02 8.63888612e-03 2.15353671e-02 2.72882205 0.00259252 435.50 -2.52543900e-02 8.27764230e-02 8.65431708e-02 1.86691773 0.04178381 435.75 -6.96210771e-02 1.54543148e-01 1.69501265e-01 1.99406269 0.09360715 436.00 -1.65674899e-01 3.88598046e-01 4.22441255e-01 1.97380144 0.30091517 436.25 -3.49541440e-01 5.98214259e-01 6.92848842e-01 2.09959776 0.39826905 436.50 -5.06185871e-01 1.07571982e+00 1.18886385e+00 2.01061211 0.48346738 436.75 -9.40456560e-01 1.51694631e+00 1.78482062e+00 2.12576817 0.49709039 437.00 -1.60455947e+00 1.79995652e+00 2.41131801e+00 2.29886390 0.48652850 437.25 -2.79253586e+00 1.56273938e+00 3.20006420e+00 2.63139899 0.58619838 437.50 -3.91040238e+00 1.21079135e+00 4.09356354e+00 2.84132144 0.71421780 437.75 -3.91777319e+00 3.42165468e-01 3.93268661e+00 3.05447698 0.74582680 438.00 -3.85298302e+00 -3.67356665e-02 3.85315814e+00 -3.13205860 0.84788725 438.25 -3.41828219e+00 -2.61338671e-01 3.42825773e+00 -3.06528788 0.81901324 438.50 -3.64905040e+00 -3.52621176e-01 3.66604835e+00 -3.04525809 0.88580152 438.75 -3.39556836e+00 -3.36528417e-01 3.41220396e+00 -3.04280712 0.86659574 439.00 -3.42828821e+00 -1.86799769e-01 3.43337359e+00 -3.08715871 0.88790939 439.25 -3.37192930e+00 -1.40705724e-01 3.37486374e+00 -3.09988830 0.88665911 439.50 -3.38786494e+00 -3.93086393e-02 3.38809298e+00 -3.12999040 0.89125351 439.75 -3.43784123e+00 4.10662986e-01 3.46228197e+00 3.02270227 0.84428574 440.00 -3.46212079e+00 1.02033056e+00 3.60934271e+00 2.85499373 0.86364695 440.25 -3.46319366e+00 1.87390085e+00 3.93766615e+00 2.64561555 0.85705180 440.50 -3.16327912e+00 2.36835047e+00 3.95163494e+00 2.49892338 0.85053630 440.75 -2.04348898e+00 3.14452372e+00 3.75018354e+00 2.14707062 0.69744583 441.00 -1.12308743e+00 3.25949697e+00 3.44755650e+00 1.90261530 0.68387212 441.25 2.30595455e-02 2.26223363e+00 2.26235116e+00 1.56060342 0.67801228 441.50 1.75960889e-01 1.76353783e+00 1.77229453e+00 1.47134826 0.69964859 441.75 1.08619258e-01 1.13559298e+00 1.14077586e+00 1.47543662 0.67031008 442.00 8.73900085e-02 1.02565843e+00 1.02937468e+00 1.48579781 0.70162868 442.25 -2.01014579e-02 7.97213149e-01 7.97466534e-01 1.59600564 0.70144382 442.50 -3.79370304e-02 6.45810291e-01 6.46923605e-01 1.62947220 0.64400548 442.75 -1.53194225e-01 5.19887296e-01 5.41988258e-01 1.85735436 0.62940450 443.00 -1.28368961e-01 4.73454192e-01 4.90548124e-01 1.83556369 0.52534730 443.25 -9.15777147e-02 2.42313551e-01 2.59041183e-01 1.93213384 0.11209217 443.50 -1.96272100e-01 -5.77886844e-02 2.04602711e-01 -2.85525239 0.03833032 443.75 -3.22000106e-01 -4.47329700e-01 5.51169601e-01 -2.19470560 0.16623800 444.00 -5.27302410e-01 -6.36267162e-01 8.26367795e-01 -2.26281985 0.23584538 444.25 -9.01913428e-01 -7.45243042e-01 1.16997223e+00 -2.45102487 0.15492715 444.50 -1.73676791e-01 -5.88277367e-01 6.13379073e-01 -1.85787072 0.02227108 444.75 1.74170118e+00 6.70812590e-01 1.86641703e+00 0.36763766 0.26779578 445.00 1.51637637e+00 1.57171028e+00 2.18395753e+00 0.80331476 0.62265765 445.25 9.27314982e-01 1.67159841e+00 1.91158424e+00 1.06431554 0.87872290 445.50 6.96447402e-01 1.54566762e+00 1.69532515e+00 1.14745991 0.89479725 445.75 4.79300491e-01 1.33658771e+00 1.41992805e+00 1.22648058 0.91516774 446.00 4.31485777e-01 1.22502694e+00 1.29879598e+00 1.23214022 0.90584803 446.25 3.78048534e-01 1.17532458e+00 1.23462892e+00 1.25959322 0.94043169 446.50 3.81606731e-01 1.08568043e+00 1.15079351e+00 1.23279398 0.93041489 446.75 3.56058522e-01 1.02846477e+00 1.08835539e+00 1.23750732 0.95261457 447.00 3.51826488e-01 9.84988802e-01 1.04593729e+00 1.22773207 0.92333578 447.25 4.25481958e-01 9.19603893e-01 1.01326513e+00 1.13744822 0.92822634 447.50 4.67096465e-01 8.44765643e-01 9.65302077e-01 1.06570620 0.91491854 447.75 4.66134504e-01 7.49997034e-01 8.83049787e-01 1.01470691 0.90929394 448.00 4.77075452e-01 6.88430690e-01 8.37578535e-01 0.96479070 0.89221165 448.25 5.37743909e-01 6.50169662e-01 8.43735208e-01 0.87975846 0.90517110 448.50 6.03368141e-01 5.24971582e-01 7.99780142e-01 0.71603007 0.84081005 448.75 6.64518144e-01 4.08048213e-01 7.79799787e-01 0.55068731 0.84165733 449.00 4.87274051e-01 2.48852240e-01 5.47141151e-01 0.47217317 0.62797679 449.25 4.51798548e-01 1.24546294e-01 4.68650944e-01 0.26898692 0.65256806 449.50 3.63666134e-01 7.22154119e-02 3.70766939e-01 0.19602608 0.49721546 449.75 3.10210937e-01 5.87454240e-03 3.10266556e-01 0.01893499 0.49110263 450.00 2.66636862e-01 2.31728379e-02 2.67641918e-01 0.08669004 0.27994566 450.25 2.16207332e-01 2.64752363e-03 2.16223542e-01 0.01224469 0.15414029 450.50 1.51261248e-01 -1.40293337e-01 2.06306048e-01 -0.74779717 0.28145793 450.75 1.06866375e-01 -1.19313732e-01 1.60175493e-01 -0.84037565 0.28180077 451.00 1.12032941e-01 -1.47737719e-01 1.85412549e-01 -0.92198961 0.29494609 451.25 8.80032260e-02 -1.64115229e-01 1.86221310e-01 -1.07858786 0.29944515 451.50 1.16123162e-02 -2.13277878e-01 2.13593772e-01 -1.51640315 0.35249944 451.75 -1.15843394e-02 -2.15504356e-01 2.15815487e-01 -1.62449919 0.39570685 452.00 -3.28566163e-02 -2.27308690e-01 2.29671064e-01 -1.71434830 0.34658576 452.25 -2.08523312e-03 -2.58306823e-01 2.58315240e-01 -1.57886885 0.32727770 452.50 5.74387562e-02 -3.23825901e-01 3.28880563e-01 -1.39524676 0.36175444 452.75 1.09490184e-02 -3.96738137e-01 3.96889192e-01 -1.54320574 0.31116981 453.00 -1.27813390e-01 -5.57486944e-01 5.71951008e-01 -1.79616848 0.48705116 453.25 -1.89227243e-01 -5.86205212e-01 6.15989854e-01 -1.88303743 0.53385281 453.50 -4.36780358e-01 -6.06759214e-01 7.47618770e-01 -2.19472573 0.61644509 453.75 -5.38999321e-01 -6.38191777e-01 8.35349634e-01 -2.27213108 0.64354247 454.00 -3.47857867e-01 -5.37686300e-01 6.40399604e-01 -2.14502669 0.39100542 454.25 -3.63461487e-01 -5.17337879e-01 6.32252113e-01 -2.18323911 0.33608129 454.50 -4.43171449e-01 -5.03806851e-01 6.70986048e-01 -2.29225138 0.26129481 454.75 -5.79062511e-01 -4.74262555e-01 7.48490723e-01 -2.45536253 0.22541127 455.00 -9.05803590e-01 -4.85987294e-01 1.02794153e+00 -2.64915288 0.18571291 455.25 -8.55159008e-01 -3.22954520e-01 9.14109705e-01 -2.78049691 0.11775438 455.50 -4.84580614e-01 4.52529388e-01 6.63024297e-01 2.39038337 0.07573867 455.75 -5.60581998e-01 6.49034973e-01 8.57612134e-01 2.28319963 0.13969516 456.00 -1.09996067e+00 1.07119453e+00 1.53537331e+00 2.36944295 0.29675341 456.25 -9.63201528e-01 1.12472839e+00 1.48080085e+00 2.27898607 0.36085575 456.50 -5.93727879e-01 1.78069775e+00 1.87707146e+00 1.89262874 0.57075448 456.75 -6.17435477e-01 1.71481686e+00 1.82258702e+00 1.91640426 0.60951851 457.00 -5.42401808e-01 1.69103687e+00 1.77589567e+00 1.88118039 0.71037445 457.25 -5.59690858e-01 1.64876908e+00 1.74117585e+00 1.89805055 0.75608693 457.50 -4.17110793e-01 1.57351205e+00 1.62785797e+00 1.82991931 0.75316914 457.75 -3.43215104e-01 1.54317637e+00 1.58088263e+00 1.78964251 0.73119764 458.00 -3.32991620e-01 1.51867437e+00 1.55475248e+00 1.78664513 0.75607134 458.25 -3.03526634e-01 1.47110259e+00 1.50208896e+00 1.77426706 0.84202296 458.50 -2.48003407e-01 1.57285470e+00 1.59228691e+00 1.72718600 0.89965520 458.75 -1.62562866e-01 1.64787277e+00 1.65587178e+00 1.66912830 0.86866502 459.00 -8.88836351e-02 1.71624523e+00 1.71854532e+00 1.62253969 0.89284769 459.25 6.08897209e-02 1.65501828e+00 1.65613800e+00 1.53402195 0.91193603 459.50 1.86377994e-01 1.70626851e+00 1.71641749e+00 1.46199633 0.93853236 459.75 3.10326240e-01 1.78612745e+00 1.81288544e+00 1.39877106 0.92479206 460.00 4.40656757e-01 1.81114378e+00 1.86397966e+00 1.33213056 0.93007215 460.25 6.74686919e-01 1.71699091e+00 1.84479273e+00 1.19638462 0.91381902 460.50 8.81601961e-01 1.63019976e+00 1.85331413e+00 1.07504866 0.93452466 460.75 1.17992087e+00 1.41212095e+00 1.84018989e+00 0.87474160 0.93809554 461.00 1.30100091e+00 1.26597689e+00 1.81529636e+00 0.77175494 0.93755874 461.25 1.21926211e+00 9.66927200e-01 1.55613248e+00 0.67048441 0.89652408 461.50 1.21287122e+00 8.22440943e-01 1.46542339e+00 0.59587230 0.89559176 461.75 1.32752544e+00 6.21725348e-01 1.46590116e+00 0.43799548 0.89162093 462.00 1.28689297e+00 4.91683850e-01 1.37762351e+00 0.36495502 0.89004797 462.25 1.22060329e+00 1.79532647e-01 1.23373594e+00 0.14603805 0.82518539 462.50 1.19207837e+00 9.91186497e-02 1.19619202e+00 0.08295694 0.85019405 462.75 9.60883661e-01 -5.01695069e-02 9.62192491e-01 -0.05216448 0.77368196 463.00 8.49868059e-01 -1.05495126e-01 8.56390646e-01 -0.12349945 0.76967070 463.25 8.29643552e-01 -9.73260804e-02 8.35332742e-01 -0.11677698 0.81724490 463.50 8.54832995e-01 -8.53206607e-02 8.59080360e-01 -0.09948027 0.82004580 463.75 8.60329361e-01 -2.72720522e-02 8.60761508e-01 -0.03168894 0.79837848 464.00 8.38965957e-01 -8.91397197e-02 8.43688193e-01 -0.10585238 0.74420113 464.25 8.40827456e-01 -3.13555611e-01 8.97389509e-01 -0.35693984 0.73637380 464.50 8.33658955e-01 -4.24810100e-01 9.35655318e-01 -0.47127665 0.75270983 464.75 6.98458633e-01 -6.87304506e-01 9.79914255e-01 -0.77734925 0.80546176 465.00 5.72433300e-01 -7.07803253e-01 9.10310567e-01 -0.89074495 0.77687893 465.25 4.59881187e-01 -5.22966192e-01 6.96408173e-01 -0.84949620 0.61856091 465.50 4.13391994e-01 -4.44435401e-01 6.06972624e-01 -0.82157079 0.55979275 465.75 4.64975839e-01 -4.68298374e-01 6.59928706e-01 -0.78895823 0.72313101 466.00 4.22495986e-01 -4.98128624e-01 6.53173013e-01 -0.86736770 0.71147484 466.25 4.15671339e-01 -5.40665941e-01 6.81984107e-01 -0.91536283 0.76254842 466.50 4.37959474e-01 -4.71735494e-01 6.43694708e-01 -0.82251007 0.69010903 466.75 6.02824598e-01 -4.89181098e-01 7.76334749e-01 -0.68170284 0.82758435 467.00 6.41909181e-01 -6.51224332e-01 9.14407199e-01 -0.79260159 0.83219648 467.25 5.43369190e-01 -1.03877115e+00 1.17230353e+00 -1.08884902 0.93123135 467.50 3.56705625e-01 -1.14399318e+00 1.19831519e+00 -1.26854249 0.94344976 467.75 2.53106390e-01 -1.17999704e+00 1.20683713e+00 -1.35950054 0.96473917 468.00 1.55309601e-01 -1.22208720e+00 1.23191647e+00 -1.44438842 0.93952064 468.25 4.69289016e-02 -1.29748899e+00 1.29833740e+00 -1.53464307 0.94618903 468.50 -2.55987540e-02 -1.30983545e+00 1.31008557e+00 -1.59033733 0.94616708 468.75 -9.31287644e-02 -1.29142259e+00 1.29477615e+00 -1.64278503 0.94266063 469.00 -1.63615170e-01 -1.23571027e+00 1.24649501e+00 -1.70243639 0.93624057 469.25 -2.01999343e-01 -1.27644209e+00 1.29232664e+00 -1.72774663 0.94767723 469.50 -1.67178397e-01 -1.35240212e+00 1.36269590e+00 -1.69378828 0.93632226 469.75 -2.16217591e-01 -1.45637691e+00 1.47233955e+00 -1.71818243 0.93671954 470.00 -4.05551277e-01 -1.72405962e+00 1.77111643e+00 -1.80182664 0.93609443 470.25 -5.88300118e-01 -1.90518709e+00 1.99394957e+00 -1.87029646 0.94918104 470.50 -9.97426892e-01 -1.97736038e+00 2.21468158e+00 -2.03797641 0.94574531 470.75 -1.24726066e+00 -1.97378179e+00 2.33483912e+00 -2.13435218 0.96172304 471.00 -1.64433077e+00 -1.88837551e+00 2.50395403e+00 -2.28722254 0.94100113 471.25 -1.95778583e+00 -1.80589608e+00 2.66349132e+00 -2.39652929 0.94610875 471.50 -2.28376533e+00 -1.55368320e+00 2.76215778e+00 -2.54419961 0.95044792 471.75 -2.37775357e+00 -1.29425346e+00 2.70717640e+00 -2.64312248 0.95708817 472.00 -2.41385270e+00 -9.76872949e-01 2.60402873e+00 -2.75704584 0.96333936 472.25 -2.42205876e+00 -7.86684297e-01 2.54661360e+00 -2.82754180 0.96671438 472.50 -2.38369798e+00 -4.80707842e-01 2.43168586e+00 -2.94259689 0.96333972 472.75 -2.38967526e+00 -3.66018507e-01 2.41754367e+00 -2.98960721 0.97473819 473.00 -2.33401442e+00 -2.45780629e-01 2.34691956e+00 -3.03667550 0.97319684 473.25 -2.33970288e+00 -1.95882168e-01 2.34788828e+00 -3.05806648 0.97061749 473.50 -2.40848189e+00 -1.54867867e-01 2.41345584e+00 -3.07738002 0.96284197 473.75 -2.45675544e+00 -5.09446433e-02 2.45728359e+00 -3.12085907 0.96707124 474.00 -2.58874617e+00 6.06040199e-02 2.58945546e+00 3.11818636 0.97707140 474.25 -2.66208063e+00 2.05116735e-01 2.66997119e+00 3.06469331 0.97541679 474.50 -2.61978929e+00 4.70049664e-01 2.66162406e+00 2.96405896 0.97605105 474.75 -2.56401709e+00 5.76695766e-01 2.62807185e+00 2.92035546 0.96445649 475.00 -2.59142845e+00 9.35058276e-01 2.75496559e+00 2.79530483 0.96824316 475.25 -2.60602493e+00 1.00519508e+00 2.79316721e+00 2.77345719 0.96487973 475.50 -2.37447000e+00 1.18556898e+00 2.65399351e+00 2.67850651 0.96064850 475.75 -2.26247459e+00 1.28281430e+00 2.60084675e+00 2.62579431 0.96199794 476.00 -2.11836305e+00 1.46011645e+00 2.57281987e+00 2.53810684 0.96668752 476.25 -1.90358017e+00 1.44464700e+00 2.38969086e+00 2.49241316 0.96193946 476.50 -1.64920636e+00 1.44782304e+00 2.19455534e+00 2.42112775 0.95934984 476.75 -1.61525976e+00 1.43727385e+00 2.16213325e+00 2.41443615 0.95695424 477.00 -1.54809037e+00 1.28947723e+00 2.01477922e+00 2.44708242 0.94189150 477.25 -1.47107062e+00 1.33237036e+00 1.98475680e+00 2.40562919 0.94086617 477.50 -1.39503670e+00 1.32828058e+00 1.92625458e+00 2.38070238 0.95463567 477.75 -1.38132828e+00 1.27020232e+00 1.87656116e+00 2.39808010 0.95389074 478.00 -1.38343034e+00 1.32062114e+00 1.91256887e+00 2.37941813 0.96852114 478.25 -1.40015303e+00 1.33688869e+00 1.93589770e+00 2.37930451 0.96458027 478.50 -1.43144352e+00 1.30969128e+00 1.94018602e+00 2.40058204 0.95153359 478.75 -1.54473892e+00 1.36732754e+00 2.06295975e+00 2.41704213 0.94694002 479.00 -1.73836013e+00 1.46626671e+00 2.27416666e+00 2.44089776 0.96891614 479.25 -1.75571258e+00 1.69438881e+00 2.43997544e+00 2.37396710 0.96062472 479.50 -1.61404044e+00 1.99660608e+00 2.56740382e+00 2.25063345 0.97010792 479.75 -1.22982673e+00 2.10996138e+00 2.44221433e+00 2.09852272 0.96671202 480.00 -1.05244519e+00 2.11456325e+00 2.36199462e+00 2.03261250 0.97944446 480.25 -9.31606781e-01 2.03287326e+00 2.23617192e+00 2.00050706 0.97402265 480.50 -8.29382271e-01 1.97757546e+00 2.14445323e+00 1.96790864 0.96963572 480.75 -8.23555961e-01 1.92947837e+00 2.09788732e+00 1.97421454 0.96729150 481.00 -8.11637892e-01 1.93814663e+00 2.10123021e+00 1.96737840 0.97377778 481.25 -7.05999750e-01 1.98442304e+00 2.10626932e+00 1.91260288 0.96474938 481.50 -5.66499396e-01 2.02066974e+00 2.09857756e+00 1.84413168 0.96586655 481.75 -3.17813093e-01 1.87929392e+00 1.90597765e+00 1.73832430 0.93313536 482.00 -2.71673616e-01 1.65120786e+00 1.67340789e+00 1.73386560 0.92936742 482.25 -4.00234254e-01 1.39041366e+00 1.44687166e+00 1.85107184 0.91247178 482.50 -5.65046418e-01 1.31096264e+00 1.42755052e+00 1.97775188 0.91811481 482.75 -9.45834979e-01 1.51145796e+00 1.78300560e+00 2.12995388 0.89786624 483.00 -1.14462569e+00 1.83311726e+00 2.16113092e+00 2.12897477 0.93413769 483.25 -1.15649743e+00 2.37534070e+00 2.64191782e+00 2.02389008 0.93843660 483.50 -9.20423875e-01 2.67885163e+00 2.83256529e+00 1.90174838 0.93889241 483.75 -3.63915728e-01 3.01306615e+00 3.03496331e+00 1.69099332 0.89819980 484.00 2.90146380e-01 3.16650768e+00 3.17977292e+00 1.47942171 0.88608379 484.25 1.04232069e+00 2.54067303e+00 2.74617040e+00 1.18148186 0.83901971 484.50 1.16031002e+00 1.84686441e+00 2.18110694e+00 1.00985657 0.83775514 484.75 9.02712680e-01 1.32166885e+00 1.60053076e+00 0.97156447 0.86473118 485.00 6.55481092e-01 1.27608891e+00 1.43459345e+00 1.09627727 0.83042068 485.25 2.20349804e-01 1.70668354e+00 1.72084942e+00 1.44239669 0.87846239 485.50 3.99487120e-01 1.97367509e+00 2.01369891e+00 1.37108670 0.88193557 485.75 1.08640215e+00 2.21428140e+00 2.46643705e+00 1.11466940 0.93933068 486.00 1.42926607e+00 2.08214061e+00 2.52549224e+00 0.96922864 0.93827048 486.25 1.79288662e+00 1.39843486e+00 2.27377714e+00 0.66242050 0.95327509 486.50 1.78771243e+00 1.21223325e+00 2.15995953e+00 0.59587070 0.95023481 486.75 1.81885440e+00 1.01362675e+00 2.08222730e+00 0.50842181 0.93950164 487.00 1.90426339e+00 8.17464174e-01 2.07230952e+00 0.40549113 0.92075462 487.25 1.93206639e+00 3.55077896e-01 1.96442379e+00 0.18175325 0.92630873 487.50 1.98665170e+00 9.27140795e-02 1.98881394e+00 0.04663468 0.92471105 487.75 1.93693360e+00 -1.38015733e-01 1.94184452e+00 -0.07113453 0.92229429 488.00 1.73706575e+00 -4.43351353e-01 1.79275147e+00 -0.24989496 0.88312711 488.25 1.37625300e+00 -6.60861514e-01 1.52669914e+00 -0.44767355 0.88729801 488.50 1.14166325e+00 -6.97093690e-01 1.33766011e+00 -0.54817343 0.83044814 488.75 9.60766421e-01 -5.78748636e-01 1.12161584e+00 -0.54216931 0.77416263 489.00 1.06058404e+00 -5.51712046e-01 1.19550185e+00 -0.47967391 0.71831369 489.25 1.28208744e+00 -4.90176229e-01 1.37259642e+00 -0.36517854 0.82405338 489.50 1.52287383e+00 -7.35892988e-01 1.69135543e+00 -0.45013899 0.79766640 489.75 1.91279798e+00 -1.09541902e+00 2.20425474e+00 -0.52008815 0.88197174 490.00 1.88426557e+00 -1.69839352e+00 2.53672964e+00 -0.73356360 0.89119341 490.25 1.74613979e+00 -2.16877752e+00 2.78434914e+00 -0.89293741 0.90204298 490.50 1.75768833e+00 -2.79918543e+00 3.30528476e+00 -1.01009389 0.88497765 490.75 1.73717929e+00 -3.54532460e+00 3.94805248e+00 -1.11518744 0.89457135 491.00 6.39561352e-01 -4.62876912e+00 4.67274462e+00 -1.43349474 0.86713771 491.25 -1.84029998e-01 -5.11547452e+00 5.11878371e+00 -1.60675598 0.87024986 491.50 -1.93181105e+00 -5.25113522e+00 5.59520464e+00 -1.92331417 0.85173052 491.75 -3.01252890e+00 -5.03651208e+00 5.86871232e+00 -2.10984553 0.88770708 492.00 -4.06199992e+00 -3.52927169e+00 5.38104098e+00 -2.42625604 0.86745460 492.25 -4.44543285e+00 -2.79482663e+00 5.25099315e+00 -2.58033983 0.90439541 492.50 -4.84936891e+00 -2.07438261e+00 5.27441390e+00 -2.73738370 0.92955368 492.75 -4.85417285e+00 -1.60850330e+00 5.11373414e+00 -2.82161459 0.94306432 493.00 -4.90965673e+00 -9.69329334e-01 5.00443090e+00 -2.94666637 0.95378005 493.25 -4.92092284e+00 -5.83439887e-01 4.95538936e+00 -3.02358047 0.95832534 493.50 -4.70773672e+00 8.83771782e-02 4.70856619e+00 3.12282211 0.95492094 493.75 -4.58489336e+00 4.59074872e-01 4.60781910e+00 3.04179756 0.96158766 494.00 -4.26247375e+00 8.22863201e-01 4.34117338e+00 2.95089029 0.96090322 494.25 -4.14816434e+00 9.21776997e-01 4.24934585e+00 2.92293228 0.96543801 494.50 -3.91082209e+00 1.21938473e+00 4.09651419e+00 2.83934787 0.96141459 494.75 -3.61610670e+00 1.33871309e+00 3.85595389e+00 2.78702944 0.95810684 495.00 -3.19095178e+00 1.48177671e+00 3.51821482e+00 2.70685454 0.95752029 495.25 -2.98746022e+00 1.48790976e+00 3.33748319e+00 2.67950487 0.95243834 495.50 -2.60826922e+00 1.64820446e+00 3.08539240e+00 2.57803620 0.95679127 495.75 -2.39556515e+00 1.64857941e+00 2.90801418e+00 2.53884388 0.95237006 496.00 -2.21741078e+00 1.65241746e+00 2.76539220e+00 2.50116977 0.93975505 496.25 -2.08808196e+00 1.55548275e+00 2.60376897e+00 2.50134183 0.92308060 496.50 -1.70932037e+00 1.14264925e+00 2.05606990e+00 2.55233460 0.90911239 496.75 -1.52626966e+00 9.57830255e-01 1.80192616e+00 2.58115246 0.90199043 497.00 -1.44101344e+00 6.74342885e-01 1.59099279e+00 2.70390043 0.84711958 497.25 -1.47434635e+00 4.74218806e-01 1.54873517e+00 2.83039658 0.84346463 497.50 -1.49021206e+00 1.62346236e-01 1.49902912e+00 3.03307889 0.87648046 497.75 -1.58778928e+00 -7.00705312e-02 1.58933467e+00 -3.09749039 0.86186547 498.00 -1.76266828e+00 -4.03243916e-01 1.80820495e+00 -2.91669370 0.86268956 498.25 -2.02494084e+00 -6.25517434e-01 2.11935308e+00 -2.84198490 0.89409358 498.50 -2.27218370e+00 -8.92517733e-01 2.44118960e+00 -2.76730703 0.89133136 498.75 -2.59853676e+00 -9.37788170e-01 2.76257850e+00 -2.79524864 0.89604780 499.00 -2.94276112e+00 -9.02502843e-01 3.07804392e+00 -2.84401350 0.92754361 499.25 -3.10517049e+00 -1.00479046e+00 3.26369233e+00 -2.82863998 0.92726696 499.50 -3.36503437e+00 -1.20185908e+00 3.57322285e+00 -2.79855261 0.93383768 499.75 -3.63537122e+00 -1.26016931e+00 3.84759023e+00 -2.80791324 0.93012518 500.00 -3.94305738e+00 -1.28139533e+00 4.14604336e+00 -2.82738331 0.92134387 500.25 -3.97263719e+00 -1.40415617e+00 4.21349033e+00 -2.80184148 0.92433425 500.50 -4.06633964e+00 -1.61170561e+00 4.37409568e+00 -2.76423426 0.91954770 500.75 -4.32555714e+00 -1.83875897e+00 4.70015735e+00 -2.73964423 0.90502475 501.00 -4.50690125e+00 -1.89846723e+00 4.89043318e+00 -2.74291481 0.91049998 501.25 -5.04960730e+00 -1.90734955e+00 5.39782513e+00 -2.78043740 0.90563583 501.50 -5.59553273e+00 -1.96446501e+00 5.93035491e+00 -2.80395835 0.92102191 501.75 -6.25717305e+00 -2.21886953e+00 6.63894544e+00 -2.80081495 0.91529074 502.00 -6.65310085e+00 -2.67887747e+00 7.17217787e+00 -2.75880305 0.91588730 502.25 -7.14950656e+00 -3.50411811e+00 7.96205299e+00 -2.68588002 0.91627340 502.50 -7.53620978e+00 -3.81865772e+00 8.44846759e+00 -2.67259306 0.90179146 502.75 -9.39134278e+00 -4.48551049e+00 1.04075513e+01 -2.69600730 0.87684238 503.00 -1.11352553e+01 -5.24965936e+00 1.23106797e+01 -2.70104895 0.91309972 503.25 -1.30142068e+01 -5.75328141e+00 1.42291892e+01 -2.72534700 0.93073680 503.50 -1.44102107e+01 -5.23112366e+00 1.53303238e+01 -2.79337049 0.93022148 503.75 -1.65296242e+01 -3.47459516e+00 1.68908640e+01 -2.93440497 0.90859937 504.00 -1.65885614e+01 -2.63711343e+00 1.67968669e+01 -2.98394009 0.91806327 504.25 -1.61807537e+01 -2.64032808e+00 1.63947590e+01 -2.97984116 0.91797354 504.50 -1.55062180e+01 -3.68235251e+00 1.59374565e+01 -2.90843570 0.90990682 504.75 -1.56139861e+01 -6.94237300e+00 1.70878057e+01 -2.72321732 0.77226132 505.00 -1.64133699e+01 -1.00165514e+01 1.92283648e+01 -2.59365747 0.78126982 505.25 -1.56665460e+01 -1.43842782e+01 2.12684772e+01 -2.39883859 0.78501576 505.50 -1.40745993e+01 -1.75030950e+01 2.24600240e+01 -2.24804479 0.74918236 505.75 -9.56090295e+00 -2.16269252e+01 2.36460305e+01 -1.98704727 0.60998417 506.00 -5.86651042e+00 -2.11823592e+01 2.19797245e+01 -1.84097699 0.52121184 506.25 -3.19788367e+00 -1.67130506e+01 1.70162428e+01 -1.75985176 0.31442495 506.50 -4.98063125e+00 -1.31051200e+01 1.40196597e+01 -1.93398905 0.26270667 506.75 -1.51573861e+00 -8.46104855e+00 8.59574349e+00 -1.74805915 0.19329516 507.00 1.73167480e+00 -9.55852845e+00 9.71412188e+00 -1.39157478 0.29406756 507.25 5.35944191e+00 -1.12595268e+01 1.24699864e+01 -1.12653912 0.62720234 507.50 6.63980501e+00 -1.00222224e+01 1.20221443e+01 -0.98567816 0.68548342 507.75 8.49789181e+00 -8.80610063e+00 1.22377111e+01 -0.80320771 0.77169764 508.00 8.19663260e+00 -7.98056396e+00 1.14400257e+01 -0.77204259 0.84386561 508.25 7.65843422e+00 -6.79796930e+00 1.02403126e+01 -0.72594694 0.89005246 508.50 7.07537648e+00 -5.54213900e+00 8.98756124e+00 -0.66447444 0.87795973 508.75 6.24217465e+00 -4.44138887e+00 7.66098424e+00 -0.61841114 0.88193149 509.00 6.15724538e+00 -3.51970577e+00 7.09224925e+00 -0.51930279 0.88319566 509.25 6.22090885e+00 -2.15475060e+00 6.58351404e+00 -0.33343938 0.90191451 509.50 6.11559893e+00 -1.39819290e+00 6.27339571e+00 -0.22476427 0.88463947 509.75 6.03756018e+00 -6.64187291e-01 6.07398367e+00 -0.10956864 0.92505177 510.00 5.36230209e+00 -1.53897755e-01 5.36451007e+00 -0.02869207 0.88401150 510.25 4.49785195e+00 7.85663438e-01 4.56595436e+00 0.17293055 0.87336237 510.50 4.40673898e+00 1.86693486e+00 4.78589534e+00 0.40073046 0.84370347 510.75 3.95078858e+00 3.40260775e+00 5.21406463e+00 0.71098782 0.88587175 511.00 3.50922068e+00 4.05365014e+00 5.36159577e+00 0.85726134 0.75914016 511.25 4.00774491e+00 5.53715193e+00 6.83535447e+00 0.94428056 0.76027101 511.50 4.09548834e+00 6.44894953e+00 7.63950096e+00 1.00499350 0.73729205 511.75 4.00189799e+00 6.88017697e+00 7.95939839e+00 1.04397408 0.67746823 512.00 5.65287504e+00 6.79593043e+00 8.83966440e+00 0.87696190 0.59893852 512.25 8.15372936e+00 7.29781802e+00 1.09426437e+01 0.73006147 0.65373825 512.50 6.68722107e+00 8.39614930e+00 1.07337900e+01 0.89821590 0.64655452 512.75 6.92714727e+00 9.01441848e+00 1.13686019e+01 0.91559019 0.68624752 513.00 9.61660833e+00 9.19584264e+00 1.33057385e+01 0.76303555 0.60453784 513.25 1.10908291e+01 8.52030409e+00 1.39857810e+01 0.65506639 0.58448237 513.50 6.08775861e+00 1.01798017e+01 1.18612465e+01 1.03183155 0.50414536 513.75 5.00253575e+00 1.10666168e+01 1.21447673e+01 1.14624856 0.52141594 514.00 5.71226264e+00 1.25438717e+01 1.37832747e+01 1.14347514 0.51945557 514.25 4.80128416e+00 1.25404971e+01 1.34281941e+01 1.20515052 0.56097361 514.50 8.95688217e-01 1.19835578e+01 1.20169845e+01 1.49619195 0.49663306 514.75 -1.63106505e-01 1.15064937e+01 1.15076497e+01 1.58497055 0.52022600 515.00 -3.21282299e+00 8.85854562e+00 9.42316625e+00 1.91872296 0.57693470 515.25 -3.05709613e+00 8.31639481e+00 8.86048866e+00 1.92306247 0.70421412 515.50 -2.32568353e+00 6.94641986e+00 7.32540462e+00 1.89386917 0.83413558 515.75 -2.11252933e+00 5.92576202e+00 6.29105998e+00 1.91324929 0.82067959 516.00 -2.00431240e+00 3.99657508e+00 4.47100442e+00 2.03564921 0.80298353 516.25 -1.72901973e+00 3.66951282e+00 4.05645579e+00 2.01112744 0.81430272 516.50 -1.51940423e+00 3.17134381e+00 3.51653391e+00 2.01758802 0.80119842 516.75 -1.33996689e+00 3.03115787e+00 3.31412572e+00 1.98703141 0.82248878 517.00 -6.30559152e-01 2.68018432e+00 2.75336028e+00 1.80186138 0.84120036 517.25 -2.74637658e-01 2.60445952e+00 2.61889962e+00 1.67585707 0.85297131 517.50 4.43048342e-01 2.09168034e+00 2.13808757e+00 1.36206685 0.82203656 517.75 7.44141993e-01 1.71889179e+00 1.87305533e+00 1.16223685 0.75706330 518.00 1.38974841e+00 9.17368088e-01 1.66522216e+00 0.58344024 0.71305159 518.25 1.38136639e+00 1.56249387e-01 1.39017516e+00 0.11263347 0.59085425 518.50 1.10481240e+00 -6.96596001e-01 1.30608439e+00 -0.56255223 0.59091266 518.75 8.03695996e-01 -7.80982170e-01 1.12065178e+00 -0.77106575 0.52765591 519.00 3.38911394e-01 -5.22399335e-01 6.22705386e-01 -0.99529384 0.40410358 519.25 3.11410270e-01 -4.62110531e-01 5.57245457e-01 -0.97781169 0.37714024 519.50 3.23771794e-01 -2.80029904e-01 4.28071164e-01 -0.71308037 0.30727890 519.75 4.04930842e-01 -2.59892756e-01 4.81158219e-01 -0.57060335 0.39588859 520.00 4.68511831e-01 -2.13924100e-01 5.15040635e-01 -0.42833174 0.50945763 520.25 5.25851293e-01 -2.74058986e-01 5.92982218e-01 -0.48044142 0.57630884 520.50 5.71118684e-01 -3.06981614e-01 6.48393602e-01 -0.49320289 0.70178400 520.75 6.07287268e-01 -2.90683608e-01 6.73271703e-01 -0.44642964 0.70175216 521.00 5.97854563e-01 -2.45917564e-01 6.46456129e-01 -0.39023823 0.76947794 521.25 7.01864403e-01 -3.13037843e-01 7.68509162e-01 -0.41953006 0.74287873 521.50 8.65816534e-01 -4.33059055e-01 9.68079756e-01 -0.46378692 0.85189449 521.75 8.88985937e-01 -6.08653130e-01 1.07738323e+00 -0.60035631 0.87240379 522.00 8.86198660e-01 -6.74135902e-01 1.11346634e+00 -0.65031729 0.88286028 522.25 8.39566441e-01 -9.27671140e-01 1.25117767e+00 -0.83521139 0.85736782 522.50 7.30239851e-01 -1.05121548e+00 1.27996259e+00 -0.96366165 0.87964386 522.75 6.22771188e-01 -1.13526128e+00 1.29485989e+00 -1.06905105 0.87415973 523.00 4.83439932e-01 -1.06926598e+00 1.17347514e+00 -1.14617817 0.85831269 523.25 2.74758189e-01 -1.07979366e+00 1.11420215e+00 -1.32162975 0.80331232 523.50 7.54356542e-02 -1.07032851e+00 1.07298353e+00 -1.50043370 0.81959237 523.75 -2.29018947e-01 -9.97244062e-01 1.02320350e+00 -1.79653403 0.82108170 524.00 -2.91080457e-01 -8.73089003e-01 9.20332679e-01 -1.89259924 0.79970425 524.25 -2.04951695e-01 -5.31226415e-01 5.69391518e-01 -1.93900916 0.55362781 524.50 -1.12911041e-01 -3.46606451e-01 3.64533860e-01 -1.88571683 0.32710575 524.75 3.84533600e-02 -1.55310698e-01 1.60000231e-01 -1.32808728 0.09266989 525.00 9.19312932e-02 -1.53889736e-01 1.79257953e-01 -1.03230245 0.14466674 525.25 1.77047135e-01 -1.39822803e-01 2.25601649e-01 -0.66845902 0.21533455 525.50 2.12632365e-01 -1.36015790e-01 2.52413981e-01 -0.56908320 0.26781562 525.75 2.92146949e-01 -2.19088021e-01 3.65170372e-01 -0.64345249 0.44853094 526.00 3.10917177e-01 -2.59991769e-01 4.05296448e-01 -0.69643304 0.53825702 526.25 3.77062822e-01 -3.53535676e-01 5.16878947e-01 -0.75320672 0.61325009 526.50 3.31536658e-01 -4.07357542e-01 5.25220641e-01 -0.88765425 0.62918054 526.75 2.49725011e-01 -4.87383679e-01 5.47636222e-01 -1.09729488 0.68184236 527.00 1.79560594e-01 -5.20720490e-01 5.50810163e-01 -1.23873376 0.70715894 527.25 1.35894075e-01 -5.15119065e-01 5.32742762e-01 -1.31286191 0.70365046 527.50 3.93456300e-02 -4.97895650e-01 4.99447852e-01 -1.49193636 0.70234014 527.75 -7.62988472e-02 -4.64488812e-01 4.70713683e-01 -1.73360649 0.67771707 528.00 -7.14127144e-02 -3.77967318e-01 3.84654480e-01 -1.75753391 0.57056150 528.25 -1.08950538e-01 -2.62523741e-01 2.84233943e-01 -1.96417684 0.46619612 528.50 -1.20261222e-01 -1.80479215e-01 2.16876713e-01 -2.15857544 0.35075328 528.75 -6.98226415e-02 -1.10105938e-01 1.30378368e-01 -2.13594165 0.28632544 529.00 -6.56097913e-02 -9.52736546e-02 1.15679358e-01 -2.17386123 0.19500479 529.25 -1.96347967e-02 -8.47138889e-02 8.69595781e-02 -1.79855251 0.13663144 529.50 -8.43291034e-02 -1.39191893e-01 1.62744526e-01 -2.11550460 0.38879270 529.75 -1.55766451e-01 -1.80142668e-01 2.38148206e-01 -2.28375358 0.69611569 530.00 -1.88412579e-01 -1.04301424e-01 2.15355722e-01 -2.63600508 0.51631163 530.25 -1.84738846e-01 -4.47061617e-03 1.84792932e-01 -3.11739772 0.57223743 530.50 -1.88086449e-01 2.68170861e-02 1.89988601e-01 2.99996867 0.52690091 530.75 -1.46674006e-01 8.41690569e-02 1.69108527e-01 2.62062214 0.53615956 531.00 -1.21295648e-01 8.42576267e-02 1.47688801e-01 2.53446852 0.41265455 531.25 -1.09523716e-01 9.19313523e-02 1.42992370e-01 2.44330001 0.50596944 531.50 -1.63510049e-01 9.58568827e-02 1.89536482e-01 2.61134882 0.54454077 531.75 -2.01295085e-01 1.26191186e-01 2.37579306e-01 2.58163072 0.71174030 532.00 -2.30011731e-01 1.43898401e-01 2.71315584e-01 2.58255243 0.69335178 532.25 -2.65654275e-01 1.48052951e-01 3.04124761e-01 2.63315113 0.74544362 532.50 -3.12765546e-01 1.96663882e-01 3.69457669e-01 2.58027251 0.75992618 532.75 -3.36276480e-01 2.60876924e-01 4.25603854e-01 2.48179480 0.81090251 533.00 -3.85998686e-01 3.77603842e-01 5.39981155e-01 2.36718778 0.89377911 533.25 -4.27044377e-01 4.54396089e-01 6.23572535e-01 2.32517375 0.93165778 533.50 -4.02277936e-01 5.51856038e-01 6.82914800e-01 2.20069170 0.92247132 533.75 -4.17145865e-01 6.34930721e-01 7.59702371e-01 2.15207275 0.93044536 534.00 -4.11880466e-01 7.91650653e-01 8.92387962e-01 2.05053646 0.92035711 534.25 -3.75938198e-01 9.28879483e-01 1.00207117e+00 1.95536697 0.93737920 534.50 -2.70524046e-01 1.15880531e+00 1.18996344e+00 1.80013968 0.94484239 534.75 -2.00220583e-01 1.28616925e+00 1.30166033e+00 1.72522883 0.95441763 535.00 7.66458392e-02 1.42817677e+00 1.43023197e+00 1.51718085 0.93515007 535.25 2.52013798e-01 1.47238254e+00 1.49379427e+00 1.40127844 0.95000818 535.50 6.36927021e-01 1.52700054e+00 1.65451101e+00 1.17562761 0.94148728 535.75 8.12886623e-01 1.54118365e+00 1.74242122e+00 1.08543606 0.95058962 536.00 9.98044310e-01 1.30008005e+00 1.63899377e+00 0.91607626 0.93107461 536.25 1.08942982e+00 1.11713827e+00 1.56040227e+00 0.79795476 0.93096992 536.50 1.25690938e+00 9.16127728e-01 1.55534922e+00 0.62984237 0.91653155 536.75 1.26016213e+00 8.14113082e-01 1.50026288e+00 0.57358520 0.91950310 537.00 1.24065329e+00 7.79969237e-01 1.46545986e+00 0.56123853 0.93029712 537.25 1.22765327e+00 7.75787418e-01 1.45223231e+00 0.56356513 0.91309890 537.50 1.24262042e+00 7.84061628e-01 1.46930533e+00 0.56288395 0.87004173 537.75 1.32404331e+00 7.01589987e-01 1.49843892e+00 0.48726838 0.83310368 538.00 1.44146041e+00 5.43097428e-01 1.54037753e+00 0.36032057 0.71854103 538.25 1.34640708e+00 5.38493728e-01 1.45009914e+00 0.38046213 0.55223463 538.50 1.25731490e+00 -5.42624734e-02 1.25848527e+00 -0.04313066 0.42544779 538.75 9.89669643e-01 -1.87897838e-01 1.00734880e+00 -0.18762600 0.43310145 539.00 1.00660237e+00 1.93676710e-01 1.02506537e+00 0.19008345 0.49544079 539.25 1.59473338e+00 1.98980932e-01 1.60709924e+00 0.12413226 0.60158971 539.50 2.50358590e+00 -9.53109364e-01 2.67887286e+00 -0.36375652 0.62513852 539.75 2.06967677e+00 -1.76156181e+00 2.71784141e+00 -0.70514911 0.60046807 540.00 9.64295683e-01 -2.38609248e+00 2.57357795e+00 -1.18673319 0.68125584 540.25 9.77636181e-02 -2.49138830e+00 2.49330572e+00 -1.53157583 0.65307073 540.50 -9.57454781e-01 -2.38446408e+00 2.56951135e+00 -1.95262853 0.72368983 540.75 -1.30925942e+00 -1.62991532e+00 2.09064205e+00 -2.24752700 0.63547238 541.00 -1.63509984e+00 -1.00865605e+00 1.92118154e+00 -2.58885568 0.69249122 541.25 -1.61057478e+00 -5.98807519e-01 1.71829030e+00 -2.78563269 0.69870217 541.50 -1.64011365e+00 -2.44330581e-01 1.65821295e+00 -2.99370849 0.76465527 541.75 -1.52613212e+00 9.56393102e-02 1.52912594e+00 3.07900672 0.63417482 542.00 -1.58675869e+00 1.96625699e-01 1.59889487e+00 3.01830456 0.65616525 542.25 -1.71793141e+00 2.09884712e-01 1.73070504e+00 3.02002220 0.60865677 542.50 -1.78827147e+00 2.47844983e-01 1.80536478e+00 3.00387524 0.54551098 542.75 -1.80461118e+00 6.33253175e-01 1.91249343e+00 2.80410882 0.30987433 543.00 -7.35638126e-01 1.40312421e+00 1.58427302e+00 2.05368330 0.13927810 543.25 8.63445439e-01 6.42684024e-01 1.07637390e+00 0.63985920 0.18507394 543.50 5.43171921e-01 6.23797895e-01 8.27139377e-01 0.85437857 0.28561986 543.75 1.75273984e-01 9.77051246e-01 9.92648028e-01 1.39329355 0.49383752 544.00 3.40263337e-01 1.12223810e+00 1.17268815e+00 1.27640574 0.62731440 544.25 7.48310384e-01 1.00633872e+00 1.25406780e+00 0.93140579 0.76292364 544.50 8.28114185e-01 8.97883399e-01 1.22146130e+00 0.82579871 0.78906401 544.75 8.59510583e-01 6.51814758e-01 1.07871262e+00 0.64882735 0.71048851 545.00 9.51815596e-01 6.51850606e-01 1.15362999e+00 0.60048543 0.75302490 545.25 8.73540759e-01 6.39306217e-01 1.08249060e+00 0.63178759 0.75613114 545.50 9.89372781e-01 6.07697211e-01 1.16110051e+00 0.55081324 0.80320623 545.75 1.30997406e+00 5.09016397e-01 1.40539308e+00 0.37061411 0.84759253 546.00 1.39978681e+00 4.21427091e-01 1.46184948e+00 0.29243375 0.86792363 546.25 1.52998856e+00 1.64811630e-01 1.53883978e+00 0.10730705 0.78747428 546.50 1.43737237e+00 -1.55999473e-01 1.44581298e+00 -0.10810787 0.69347732 546.75 1.08359977e+00 -6.78221535e-01 1.27834773e+00 -0.55924388 0.59776847 547.00 7.91073466e-01 -9.07934641e-01 1.20421864e+00 -0.85407200 0.56657766 547.25 3.25394727e-01 -7.69928130e-01 8.35865452e-01 -1.17093480 0.36651759 547.50 1.52408013e-01 -5.60998616e-01 5.81332650e-01 -1.30552610 0.19915617 547.75 1.50348530e-01 -2.80887611e-01 3.18594618e-01 -1.07933846 0.07779998 548.00 1.66177652e-01 -4.30318011e-02 1.71658812e-01 -0.25338485 0.02215226 548.25 3.60911504e-01 5.75777971e-01 6.79542041e-01 1.01088638 0.16489909 548.50 5.12731172e-01 5.07721839e-01 7.21577938e-01 0.78048927 0.11065140 548.75 6.93231549e-01 -6.09589565e-02 6.95906585e-01 -0.08770888 0.05711902 549.00 6.02835247e-01 -6.58244783e-01 8.92578584e-01 -0.82930808 0.07650535 549.25 9.33001047e-01 -1.18815044e+00 1.51069270e+00 -0.90511114 0.23130792 549.50 1.00879760e+00 -1.41269588e+00 1.73590963e+00 -0.95067382 0.33174391 549.75 8.78931383e-01 -1.71390962e+00 1.92613773e+00 -1.09694343 0.55277454 550.00 4.76625804e-01 -1.88038023e+00 1.93984587e+00 -1.32255155 0.54837780 550.25 1.49347893e-01 -1.99481438e+00 2.00039726e+00 -1.49606768 0.61978857 550.50 -2.43793894e-01 -1.98439554e+00 1.99931516e+00 -1.69303925 0.59622872 550.75 -4.52177704e-01 -2.06918392e+00 2.11801481e+00 -1.78594358 0.75353505 551.00 -4.83233210e-01 -2.25421111e+00 2.30542449e+00 -1.78196938 0.78095678 551.25 -6.00681188e-01 -2.40236135e+00 2.47631944e+00 -1.81581058 0.80020693 551.50 -8.86999313e-01 -2.46884595e+00 2.62335055e+00 -1.91571162 0.78787570 551.75 -1.21161738e+00 -2.56396305e+00 2.83582849e+00 -2.01224909 0.87391877 552.00 -1.67700419e+00 -2.85655370e+00 3.31243748e+00 -2.10165610 0.86551678 552.25 -2.42293626e+00 -2.76449706e+00 3.67601199e+00 -2.29044550 0.89360333 552.50 -2.97696716e+00 -2.45621619e+00 3.85944704e+00 -2.45174898 0.89070133 552.75 -3.71838786e+00 -2.09612908e+00 4.26850857e+00 -2.62827702 0.89865586 553.00 -4.22703049e+00 -1.63086048e+00 4.53072761e+00 -2.77337242 0.88983867 553.25 -4.62749777e+00 -8.85098701e-01 4.71138359e+00 -2.95260583 0.86721923 553.50 -4.72443133e+00 3.03980382e-01 4.73420061e+00 3.07733901 0.87803810 553.75 -4.55874649e+00 7.25548336e-01 4.61612282e+00 2.98376119 0.87995326 554.00 -3.89012206e+00 9.54012960e-01 4.00539516e+00 2.90109912 0.83881577 554.25 -3.86514436e+00 1.53469546e+00 4.15868141e+00 2.76362305 0.80699948 554.50 -4.21619769e+00 1.46478023e+00 4.46339603e+00 2.80722048 0.85829694 554.75 -4.11491572e+00 1.14695882e+00 4.27177316e+00 2.86976012 0.83990631 555.00 -3.64917383e+00 1.83219110e+00 4.08330673e+00 2.67627939 0.82695948 555.25 -3.71962749e+00 1.99384460e+00 4.22031338e+00 2.64953555 0.85254704 555.50 -4.00075549e+00 2.08163260e+00 4.50990452e+00 2.66182947 0.84018378 555.75 -3.96714118e+00 2.25134516e+00 4.56144322e+00 2.62541451 0.84180515 556.00 -4.36942652e+00 2.75044640e+00 5.16302658e+00 2.57978156 0.85075927 556.25 -4.77178099e+00 3.13708075e+00 5.71061901e+00 2.56001652 0.84121819 556.50 -5.29759151e+00 4.53858811e+00 6.97590552e+00 2.43320633 0.86637506 556.75 -5.25039533e+00 5.57165567e+00 7.65571669e+00 2.32651749 0.86790499 557.00 -4.10011940e+00 7.27706291e+00 8.35264172e+00 2.08389238 0.80531108 557.25 -2.07613849e+00 7.61742707e+00 7.89528633e+00 1.83688444 0.77590861 557.50 1.18555686e-01 8.34093241e+00 8.34177493e+00 1.55658356 0.79215029 557.75 7.75722665e-01 8.40623124e+00 8.44194701e+00 1.47877745 0.76993069 558.00 2.61567081e+00 7.03952566e+00 7.50977066e+00 1.21503688 0.69521675 558.25 3.66379663e+00 5.57522635e+00 6.67132330e+00 0.98940656 0.73038113 558.50 3.05222607e+00 5.04316075e+00 5.89487526e+00 1.02654680 0.72405096 558.75 2.56360985e+00 3.91788106e+00 4.68208153e+00 0.99137913 0.65090698 559.00 2.12113617e+00 3.07886307e+00 3.73879880e+00 0.96753528 0.60433306 559.25 1.97524375e+00 3.06912008e+00 3.64980629e+00 0.99894305 0.59743868 559.50 2.75517772e+00 2.91059548e+00 4.00781365e+00 0.81282227 0.73786606 559.75 2.80546577e+00 2.93776475e+00 4.06215459e+00 0.80842973 0.76309868 560.00 1.95649580e+00 2.39945656e+00 3.09600833e+00 0.88674070 0.53073594 560.25 1.56555027e+00 2.27183023e+00 2.75901436e+00 0.96741375 0.54875502 560.50 1.50440760e+00 2.74940297e+00 3.13408024e+00 1.07012376 0.61167250 560.75 1.43766154e+00 2.62605693e+00 2.99383461e+00 1.06990518 0.53751588 561.00 1.69395884e+00 2.79754002e+00 3.27043219e+00 1.02632987 0.61599586 561.25 1.67208350e+00 3.09410563e+00 3.51700908e+00 1.07534621 0.61383373 561.50 1.33076228e+00 3.70932845e+00 3.94081790e+00 1.22633805 0.58733798 561.75 1.50924164e+00 4.51627197e+00 4.76177728e+00 1.24828519 0.61648387 562.00 2.21532030e+00 5.68524125e+00 6.10160733e+00 1.19923400 0.70156732 562.25 3.47794923e+00 4.56626677e+00 5.73994104e+00 0.91987359 0.57742795 562.50 5.20050893e+00 3.20293854e+00 6.10770894e+00 0.55202106 0.43761477 562.75 3.38040684e+00 1.38035204e+00 3.65137264e+00 0.38767446 0.15046562 563.00 2.75855644e+00 -1.82588052e+00 3.30809209e+00 -0.58469332 0.11950896 563.25 2.13170789e+00 -2.27581546e+00 3.11825505e+00 -0.81808234 0.25870714 563.50 1.38909287e+00 -2.07788540e+00 2.49943728e+00 -0.98151676 0.30738513 563.75 4.25474018e-01 -2.24566951e+00 2.28562019e+00 -1.38355154 0.41186780 564.00 7.94370675e-03 -1.72965568e+00 1.72967393e+00 -1.56620371 0.37396934 564.25 1.24747122e-01 -1.17504827e+00 1.18165151e+00 -1.46502909 0.19227716 564.50 -2.27833026e-01 -8.44367183e-01 8.74564936e-01 -1.83434687 0.10930568 564.75 -1.08770241e-01 1.91293809e-02 1.10439570e-01 2.96750333 0.00209491 565.00 4.23667016e-02 2.59610856e-01 2.63045117e-01 1.40902922 0.01198353 565.25 5.04994617e-01 7.02865377e-01 8.65470567e-01 0.94777514 0.08951765 565.50 7.43414762e-01 6.70786367e-01 1.00130907e+00 0.73408676 0.10694230 565.75 5.91289657e-01 1.01328839e+00 1.17319087e+00 1.04257112 0.22760124 566.00 4.08696321e-01 9.63810099e-01 1.04688232e+00 1.16973708 0.21434004 566.25 -3.20339052e-01 1.49846552e+00 1.53232374e+00 1.78140424 0.36608443 566.50 -1.66581375e-01 2.47074722e+00 2.47635644e+00 1.63811590 0.64744486 566.75 5.49961185e-01 3.27108317e+00 3.31699297e+00 1.40422600 0.75099905 567.00 1.11711200e+00 3.79946879e+00 3.96029069e+00 1.28483665 0.82918105 567.25 2.11043018e+00 4.33047928e+00 4.81736093e+00 1.11732523 0.89766245 567.50 2.92015570e+00 4.45320967e+00 5.32525921e+00 0.99039528 0.90986017 567.75 4.21019056e+00 3.64483405e+00 5.56870899e+00 0.71354819 0.93644005 568.00 4.54684939e+00 3.16563219e+00 5.54031286e+00 0.60818820 0.94799694 568.25 5.07605436e+00 2.37722008e+00 5.60513186e+00 0.43798434 0.96727820 568.50 5.34100906e+00 1.94966793e+00 5.68573503e+00 0.35000784 0.96781456 568.75 5.59575406e+00 1.13762386e+00 5.71022342e+00 0.20056782 0.97039298 569.00 5.65147325e+00 8.59570191e-01 5.71646839e+00 0.15093983 0.97169597 569.25 5.67826009e+00 4.75296584e-01 5.69811763e+00 0.08350994 0.96651709 569.50 5.61288188e+00 2.35040355e-01 5.61780090e+00 0.04185071 0.95767235 569.75 5.59473250e+00 2.90897761e-02 5.59480813e+00 0.00519945 0.94487282 570.00 5.76843890e+00 -2.29383400e-01 5.77299784e+00 -0.03974431 0.95539681 570.25 6.12634559e+00 -1.06191620e+00 6.21769864e+00 -0.17163065 0.95255131 570.50 6.11737202e+00 -1.52802995e+00 6.30532441e+00 -0.24477664 0.94155838 570.75 5.29507471e+00 -2.41778631e+00 5.82095412e+00 -0.42833754 0.86506793 571.00 4.57107690e+00 -2.88893639e+00 5.40746683e+00 -0.56361966 0.86365559 571.25 4.09405941e+00 -2.68710577e+00 4.89712772e+00 -0.58082111 0.90249430 571.50 4.00974614e+00 -2.57557237e+00 4.76567279e+00 -0.57096301 0.90836512 571.75 3.94911143e+00 -2.69079764e+00 4.77868947e+00 -0.59811142 0.93611390 572.00 3.73743402e+00 -2.35505420e+00 4.41754382e+00 -0.56227691 0.93153105 572.25 3.50779074e+00 -2.13227619e+00 4.10502103e+00 -0.54618523 0.93932495 572.50 3.49743767e+00 -2.08701257e+00 4.07279900e+00 -0.53800879 0.94780904 572.75 3.70352381e+00 -1.98218157e+00 4.20061095e+00 -0.49142116 0.95085962 573.00 4.26732755e+00 -2.00539140e+00 4.71504815e+00 -0.43931241 0.94897847 573.25 4.63788889e+00 -2.09064183e+00 5.08731723e+00 -0.42349778 0.96045689 573.50 4.78577205e+00 -2.28728391e+00 5.30427015e+00 -0.44583962 0.95881765 573.75 5.01507229e+00 -2.34646768e+00 5.53686379e+00 -0.43762561 0.96141457 574.00 5.57208441e+00 -2.70082072e+00 6.19213672e+00 -0.45133743 0.95491920 574.25 6.07436152e+00 -2.80130509e+00 6.68918367e+00 -0.43210286 0.95512580 574.50 6.75935003e+00 -3.29316578e+00 7.51889312e+00 -0.45335652 0.92790487 574.75 7.42641435e+00 -3.70334771e+00 8.29857906e+00 -0.46258495 0.92837796 575.00 8.36203521e+00 -4.32649009e+00 9.41499598e+00 -0.47746798 0.88496413 575.25 9.09047921e+00 -5.28017973e+00 1.05127118e+01 -0.52621753 0.90288798 575.50 8.95652611e+00 -6.97766275e+00 1.13537279e+01 -0.66184101 0.80985122 575.75 8.69761717e+00 -9.01942866e+00 1.25299097e+01 -0.80356011 0.82823003 576.00 9.04470796e+00 -9.69110149e+00 1.32561001e+01 -0.81988492 0.87045551 576.25 9.37533961e+00 -1.05157033e+01 1.40881868e+01 -0.84266599 0.86951577 576.50 1.01736851e+01 -1.05465097e+01 1.46537618e+01 -0.80338952 0.87062596 576.75 1.09384159e+01 -1.08432876e+01 1.54021371e+01 -0.78103084 0.87636685 577.00 1.44084431e+01 -1.08716991e+01 1.80498497e+01 -0.64639828 0.87009992 577.25 1.63328990e+01 -9.44514440e+00 1.88672823e+01 -0.52430293 0.83198087 577.50 1.89754474e+01 -5.77896210e+00 1.98359272e+01 -0.29562536 0.71545025 577.75 2.06351078e+01 -4.09079103e+00 2.10366880e+01 -0.19570675 0.64529787 578.00 2.09894738e+01 5.91835090e+00 2.18079088e+01 0.27483230 0.53326172 578.25 1.83532094e+01 1.25770511e+01 2.22491013e+01 0.60077696 0.59954077 578.50 9.90999741e+00 1.79180138e+01 2.04759192e+01 1.06559568 0.65359922 578.75 7.18446273e+00 1.96894012e+01 2.09592229e+01 1.22091867 0.70986147 579.00 5.98028506e+00 2.24093875e+01 2.31936297e+01 1.31000862 0.84179368 579.25 5.46930400e+00 2.15339490e+01 2.22176561e+01 1.32207043 0.84441968 579.50 5.88422791e+00 1.80908863e+01 1.90237826e+01 1.25632997 0.89142820 579.75 6.17896943e+00 1.64225267e+01 1.75464824e+01 1.21093055 0.88400592 580.00 5.91491852e+00 1.49763907e+01 1.61021284e+01 1.19465137 0.90937645 580.25 5.99401276e+00 1.38464504e+01 1.50881535e+01 1.16226041 0.90296719 580.50 6.36396045e+00 1.11534283e+01 1.28412988e+01 1.05228761 0.88145564 580.75 6.29949941e+00 9.52827687e+00 1.14224233e+01 0.98663151 0.89299426 581.00 7.50225393e+00 8.19254420e+00 1.11086270e+01 0.82935194 0.91891513 581.25 7.41567691e+00 6.88256798e+00 1.01174110e+01 0.74813051 0.89948937 581.50 6.89871624e+00 5.29761040e+00 8.69810104e+00 0.65486689 0.94226320 581.75 6.47521322e+00 4.15547668e+00 7.69391790e+00 0.57055463 0.93414800 582.00 5.69332074e+00 3.01403724e+00 6.44191909e+00 0.48688912 0.92668111 582.25 4.61226340e+00 2.55525264e+00 5.27278766e+00 0.50591878 0.91196716 582.50 3.67089075e+00 2.34714698e+00 4.35712495e+00 0.56888345 0.92587523 582.75 3.16449672e+00 2.44255508e+00 3.99751358e+00 0.65734667 0.91342161 583.00 2.77038630e+00 2.59671118e+00 3.79709747e+00 0.75305023 0.92211457 583.25 2.80111147e+00 2.86800909e+00 4.00895268e+00 0.79719797 0.93911648 583.50 2.90383760e+00 2.99716036e+00 4.17315744e+00 0.80121159 0.92720790 583.75 3.33809142e+00 2.71936791e+00 4.30555643e+00 0.68360876 0.90462073 584.00 3.90475064e+00 2.44084411e+00 4.60486672e+00 0.55866837 0.92483010 584.25 4.37053382e+00 1.93095127e+00 4.77808944e+00 0.41602338 0.90660760 584.50 4.64482873e+00 1.57733302e+00 4.90534539e+00 0.32737010 0.91529780 584.75 4.55606371e+00 1.26580318e+00 4.72863344e+00 0.27099370 0.86726231 585.00 4.78046671e+00 8.33468537e-01 4.85257991e+00 0.17261373 0.85237814 585.25 4.80314423e+00 -3.39399568e-01 4.81512061e+00 -0.07054470 0.76435529 585.50 4.17643165e+00 -1.97641557e+00 4.62047615e+00 -0.44200374 0.68658273 585.75 2.21494356e+00 -1.74294002e+00 2.81847740e+00 -0.66670220 0.37169791 586.00 1.89423211e+00 -1.88181508e+00 2.67008301e+00 -0.78210981 0.37490003 586.25 1.29755151e+00 -1.32180746e+00 1.85224590e+00 -0.79465816 0.21533435 586.50 1.00818867e+00 -6.18598867e-01 1.18283936e+00 -0.55034101 0.10120835 586.75 1.87683827e+00 -5.50753361e-01 1.95597831e+00 -0.28543447 0.15611967 587.00 2.62453150e+00 -1.29101352e+00 2.92487290e+00 -0.45714863 0.24770210 587.25 2.70836086e+00 -2.81846343e+00 3.90883034e+00 -0.80531702 0.27722207 587.50 1.26966820e+00 -4.18935088e+00 4.37752421e+00 -1.27652505 0.29661732 587.75 -1.27863706e+00 -5.45841823e+00 5.60617894e+00 -1.80089787 0.41813331 588.00 -1.63429940e+00 -6.06444493e+00 6.28079826e+00 -1.83403154 0.49406264 588.25 -3.02410123e+00 -5.85789519e+00 6.59242932e+00 -2.04735425 0.54361174 588.50 -4.45793792e+00 -5.89269511e+00 7.38898275e+00 -2.21845678 0.66189098 588.75 -5.29934733e+00 -5.52829105e+00 7.65800784e+00 -2.33505326 0.70608831 589.00 -6.40827628e+00 -4.90092747e+00 8.06753339e+00 -2.48869867 0.73110252 589.25 -7.27436028e+00 -3.87600144e+00 8.24255450e+00 -2.65202684 0.84229891 589.50 -7.41847038e+00 -3.33346988e+00 8.13300216e+00 -2.71928162 0.84574554 589.75 -7.40595160e+00 -2.41082713e+00 7.78846625e+00 -2.82688540 0.85246360 590.00 -7.60245626e+00 -2.12404105e+00 7.89359814e+00 -2.86915082 0.84067213 590.25 -7.50548384e+00 -1.42567558e+00 7.63968838e+00 -2.95387782 0.83118405 590.50 -7.34711697e+00 -5.41233702e-01 7.36702530e+00 -3.06805934 0.85902243 590.75 -7.08217516e+00 3.61774821e-01 7.09140931e+00 3.09055457 0.85035301 591.00 -6.88902212e+00 9.01445823e-01 6.94775002e+00 3.01147940 0.84838193 591.25 -6.56600737e+00 2.21515704e+00 6.92960125e+00 2.81621582 0.88415957 591.50 -6.16507097e+00 2.04628484e+00 6.49579723e+00 2.82111837 0.86722449 591.75 -5.60865437e+00 2.07038442e+00 5.97858641e+00 2.78796849 0.90389127 592.00 -4.97541605e+00 1.93200884e+00 5.33736106e+00 2.77120343 0.88320254 592.25 -4.83701654e+00 1.79757678e+00 5.16023364e+00 2.78578044 0.89555612 592.50 -5.07820430e+00 1.69322224e+00 5.35305151e+00 2.81975571 0.86320862 592.75 -5.44737246e+00 1.61469157e+00 5.68164550e+00 2.85342663 0.81380476 593.00 -5.81032063e+00 1.63668296e+00 6.03643578e+00 2.86702169 0.83206031 593.25 -6.21624320e+00 1.86881700e+00 6.49108284e+00 2.84955388 0.85059134 593.50 -5.83857659e+00 2.04206414e+00 6.18538621e+00 2.80513721 0.75361887 593.75 -5.78165947e+00 2.64078344e+00 6.35620353e+00 2.71313812 0.77257073 594.00 -5.67745631e+00 3.59080397e+00 6.71769181e+00 2.57764179 0.74342604 594.25 -5.08610110e+00 4.40236853e+00 6.72675799e+00 2.42812946 0.69655458 594.50 -4.23926597e+00 4.27175239e+00 6.01824263e+00 2.35237752 0.63329618 594.75 -4.40098816e+00 5.16316374e+00 6.78431696e+00 2.27667168 0.72392915 595.00 -3.90129510e+00 6.42477903e+00 7.51650777e+00 2.11651238 0.81868829 595.25 -3.09630312e+00 6.39154387e+00 7.10203676e+00 2.02191655 0.83778514 595.50 -2.87619350e+00 5.80569274e+00 6.47908614e+00 2.03076454 0.82202295 595.75 -2.37159499e+00 5.29133137e+00 5.79850415e+00 1.99215555 0.82512912 596.00 -2.44949948e+00 5.39415625e+00 5.92426953e+00 1.99705660 0.87196716 596.25 -2.86033942e+00 5.35824914e+00 6.07390940e+00 2.06113230 0.90891559 596.50 -2.93155841e+00 5.24079701e+00 6.00499692e+00 2.08080693 0.89955677 596.75 -3.17468741e+00 5.53925215e+00 6.38450894e+00 2.09122083 0.87011132 597.00 -3.32406524e+00 6.58388222e+00 7.37542642e+00 2.03833968 0.85780907 597.25 -3.17755642e+00 7.07095369e+00 7.75211267e+00 1.99313586 0.84054372 597.50 -1.26586461e+00 8.73444706e+00 8.82569990e+00 1.71472208 0.87556116 597.75 -6.38895794e-01 8.87247940e+00 8.89545268e+00 1.64268096 0.91019766 598.00 4.56473267e-01 9.01244385e+00 9.02399646e+00 1.52019035 0.89426902 598.25 1.36556670e+00 9.09570015e+00 9.19763740e+00 1.42177610 0.91022999 598.50 2.14873566e+00 8.51988307e+00 8.78666446e+00 1.32374582 0.90890642 598.75 2.82713963e+00 7.99125834e+00 8.47661066e+00 1.23075886 0.86957356 599.00 4.80719188e+00 7.00507918e+00 8.49589478e+00 0.96936252 0.89708216 599.25 4.98367380e+00 6.22842258e+00 7.97685730e+00 0.89596378 0.91093926 599.50 5.01635550e+00 4.55999824e+00 6.77918921e+00 0.73777959 0.90719932 599.75 5.08293160e+00 3.85679231e+00 6.38052040e+00 0.64909236 0.92721582 600.00 4.37371171e+00 2.92128327e+00 5.25958649e+00 0.58886880 0.91872471 600.25 4.07573452e+00 2.59325117e+00 4.83079326e+00 0.56665970 0.93075972 600.50 3.93034005e+00 2.58227454e+00 4.70273481e+00 0.58128771 0.93009739 600.75 3.93494353e+00 2.33157543e+00 4.57384134e+00 0.53490938 0.92540122 601.00 4.42987810e+00 2.00926746e+00 4.86425490e+00 0.42582020 0.95447946 601.25 4.66263455e+00 1.63610148e+00 4.94135497e+00 0.33747313 0.92309970 601.50 5.03187457e+00 7.89523221e-01 5.09343780e+00 0.15563547 0.85948561 601.75 4.86041324e+00 1.07897207e-01 4.86161071e+00 0.02219554 0.80280490 602.00 4.16683640e+00 -1.40948109e+00 4.39876830e+00 -0.32617949 0.76863956 602.25 2.68162284e+00 -2.04714255e+00 3.37370622e+00 -0.65202013 0.59199830 602.50 8.68577012e-01 -2.32875663e+00 2.48546444e+00 -1.21379878 0.53192685 602.75 1.24628766e-01 -1.88118978e+00 1.88531359e+00 -1.50464303 0.41989076 603.00 -9.12534888e-01 -8.66104331e-01 1.25811630e+00 -2.38229310 0.31018367 603.25 -9.14009603e-01 -3.44840656e-01 9.76897452e-01 -2.78082160 0.28489260 603.50 -8.31111349e-01 -1.60536758e-01 8.46473936e-01 -2.95078341 0.31013932 603.75 -8.14443152e-01 3.16376126e-01 8.73734228e-01 2.77107659 0.32265605 604.00 -7.98821608e-01 5.90801690e-01 9.93560566e-01 2.50478632 0.45542037 604.25 -7.15261309e-01 7.66365326e-01 1.04829125e+00 2.32171633 0.41804176 604.50 -6.03824380e-01 8.15334284e-01 1.01458064e+00 2.20824459 0.36942482 604.75 -4.77040314e-01 1.00406395e+00 1.11162578e+00 2.01433400 0.44251262 605.00 -1.35957919e-01 1.02759789e+00 1.03655293e+00 1.70233886 0.49095602 605.25 9.54556033e-02 6.50379151e-01 6.57346798e-01 1.42506761 0.22018666 605.50 1.50241567e-01 3.82969952e-01 4.11386087e-01 1.19693990 0.09708260 605.75 -3.53922763e-01 3.44001936e-01 4.93557144e-01 2.37040829 0.11309818 606.00 -6.94969334e-01 3.65336990e-01 7.85145523e-01 2.65760652 0.23290801 606.25 -1.21488510e+00 6.58733960e-01 1.38198272e+00 2.64474285 0.36612505 606.50 -1.38101396e+00 8.64014095e-01 1.62902422e+00 2.58253506 0.45042910 606.75 -5.14224358e-01 8.47959184e-01 9.91696258e-01 2.11592732 0.19486168 607.00 -3.70563368e-01 8.81956424e-01 9.56642224e-01 1.96856086 0.14923007 607.25 -8.91014503e-01 5.69671755e-01 1.05755981e+00 2.57273942 0.16438443 607.50 -1.25272562e+00 3.94343525e-02 1.25334614e+00 3.11012420 0.24049407 607.75 -1.22648730e+00 8.29622956e-02 1.22928997e+00 3.07405334 0.34629759 608.00 -1.25657927e+00 2.23741411e-01 1.27634309e+00 2.96538339 0.35181276 608.25 -1.83962484e+00 -3.26021794e-01 1.86829060e+00 -2.96619194 0.61325111 608.50 -1.96994414e+00 -6.92045069e-01 2.08796702e+00 -2.80375851 0.71365633 608.75 -2.03221244e+00 -1.22793073e+00 2.37438440e+00 -2.59806614 0.71946961 609.00 -1.95688501e+00 -1.62633872e+00 2.54447963e+00 -2.44818245 0.65604184 609.25 -8.05228966e-01 -2.93021144e+00 3.03883741e+00 -1.83897877 0.41639329 609.50 5.65106802e-01 -2.82442113e+00 2.88039935e+00 -1.37332499 0.27267859 609.75 3.05659357e+00 -8.21092101e-01 3.16495758e+00 -0.26243429 0.34017804 610.00 3.12529960e+00 1.58031860e-01 3.12929252e+00 0.05052232 0.43455999 610.25 2.53760199e+00 1.54128880e+00 2.96900573e+00 0.54582834 0.60973990 610.50 2.19345695e+00 1.86587685e+00 2.87971350e+00 0.70487466 0.73168843 610.75 1.29523539e+00 1.67691915e+00 2.11888946e+00 0.91311901 0.76902590 611.00 8.60445600e-01 1.82813387e+00 2.02050491e+00 1.13088778 0.83592285 611.25 5.07056355e-01 1.97012055e+00 2.03432572e+00 1.31889025 0.90292955 611.50 3.37259013e-01 2.12617810e+00 2.15276031e+00 1.41348478 0.91480531 611.75 2.87894735e-01 2.45718308e+00 2.47399112e+00 1.45416354 0.96199418 612.00 2.45473698e-01 2.50499122e+00 2.51698994e+00 1.47311437 0.95614553 612.25 3.21559565e-01 2.62627473e+00 2.64588728e+00 1.44896330 0.94925905 612.50 4.07795686e-01 2.63563076e+00 2.66699210e+00 1.41728943 0.94660924 612.75 5.75676870e-01 2.66640792e+00 2.72784440e+00 1.35816031 0.95723324 613.00 7.44409577e-01 2.59420214e+00 2.69889428e+00 1.29135342 0.94982438 613.25 9.26821095e-01 2.45989867e+00 2.62870668e+00 1.21047297 0.96137045 613.50 9.78600404e-01 2.40183310e+00 2.59354217e+00 1.18389354 0.96249840 613.75 1.12273206e+00 2.32807115e+00 2.58465521e+00 1.12144240 0.96812312 614.00 1.33017450e+00 2.06814141e+00 2.45897806e+00 0.99923477 0.96550042 614.25 1.44729188e+00 1.69320828e+00 2.22746674e+00 0.86354355 0.95653059 614.50 1.34129258e+00 1.26314648e+00 1.84244534e+00 0.75540220 0.94170469 614.75 1.12726256e+00 9.88871038e-01 1.49952886e+00 0.72009287 0.93929884 615.00 7.78785383e-01 8.91353851e-01 1.18364621e+00 0.85269703 0.88050044 615.25 5.35230174e-01 8.67433591e-01 1.01927051e+00 1.01795077 0.90457170 615.50 2.94554612e-01 9.04361125e-01 9.51121162e-01 1.25592724 0.91660055 615.75 2.01619710e-01 9.63947049e-01 9.84806794e-01 1.36460825 0.95436344 616.00 1.43485863e-01 1.04338352e+00 1.05320339e+00 1.43413376 0.94108870 616.25 1.40574610e-01 1.08144196e+00 1.09054021e+00 1.44153300 0.93489681 616.50 1.98194166e-01 1.10683786e+00 1.12444252e+00 1.39361073 0.94050078 616.75 1.86562783e-01 1.09162814e+00 1.10745549e+00 1.40152843 0.92273327 617.00 9.39211765e-02 9.95042220e-01 9.99464961e-01 1.47668601 0.89610474 617.25 -8.12863745e-03 9.30957793e-01 9.30993280e-01 1.57952758 0.85839881 617.50 -1.02132942e-01 8.64872914e-01 8.70882481e-01 1.68834206 0.86666093 617.75 -1.55739998e-01 8.53707199e-01 8.67796595e-01 1.75123996 0.85473630 618.00 -1.75956380e-01 8.71954551e-01 8.89530993e-01 1.76991759 0.78309658 618.25 -1.90648927e-01 8.70381067e-01 8.91016394e-01 1.78643149 0.75748167 618.50 -4.78318070e-01 7.61070387e-01 8.98897275e-01 2.13189472 0.77192763 618.75 -6.07611641e-01 7.77840579e-01 9.87029823e-01 2.23393839 0.76678377 619.00 -7.38831040e-01 7.48758039e-01 1.05190775e+00 2.34952138 0.78593349 619.25 -8.91154740e-01 8.21976363e-01 1.21235387e+00 2.39655381 0.81881987 619.50 -1.05464337e+00 1.08389308e+00 1.51231506e+00 2.34251790 0.80221083 619.75 -1.15054945e+00 1.19289542e+00 1.65733627e+00 2.33812649 0.75168380 620.00 -1.63035268e+00 1.50570453e+00 2.21927826e+00 2.39592035 0.78211307 620.25 -1.70076155e+00 1.96493142e+00 2.59875842e+00 2.28425339 0.82014004 620.50 -1.40713538e+00 2.47046354e+00 2.84310043e+00 2.08855047 0.90772495 620.75 -1.18176086e+00 2.55795083e+00 2.81774222e+00 2.00358052 0.92137889 621.00 -7.44739516e-01 2.35384519e+00 2.46885077e+00 1.87722366 0.91483386 621.25 -6.99910211e-01 2.22394567e+00 2.33148207e+00 1.87569833 0.92327058 621.50 -6.84386889e-01 2.16100010e+00 2.26678337e+00 1.87750217 0.94951114 621.75 -7.62187677e-01 2.16323558e+00 2.29358197e+00 1.90955148 0.95141498 622.00 -8.18629757e-01 2.26034582e+00 2.40402120e+00 1.91827173 0.94959219 622.25 -8.14901841e-01 2.30262395e+00 2.44256875e+00 1.91094254 0.94683921 622.50 -8.35980181e-01 2.45834424e+00 2.59659763e+00 1.89858703 0.92319229 622.75 -8.41972110e-01 2.58776270e+00 2.72129249e+00 1.88535996 0.90418336 623.00 -9.77026135e-01 2.81326512e+00 2.97809347e+00 1.90505717 0.93976131 623.25 -9.82843686e-01 2.99037980e+00 3.14775366e+00 1.88834268 0.91877475 623.50 -1.07110040e+00 3.26658820e+00 3.43771065e+00 1.88764510 0.91716614 623.75 -9.57616223e-01 3.49171182e+00 3.62064639e+00 1.83846893 0.86242435 624.00 -8.35535037e-01 3.99639217e+00 4.08280164e+00 1.77689987 0.85218603 624.25 -9.41060513e-02 4.06038543e+00 4.06147581e+00 1.59396881 0.78701901 624.50 9.68464790e-01 4.08794434e+00 4.20109664e+00 1.33817744 0.76282651 624.75 1.77712060e+00 3.59090595e+00 4.00658997e+00 1.11124123 0.70999648 625.00 2.86850834e+00 2.92262360e+00 4.09512744e+00 0.79474240 0.67156509 625.25 3.33462879e+00 1.55629446e+00 3.67991869e+00 0.43666024 0.63240759 625.50 3.37933625e+00 5.53036142e-01 3.42429007e+00 0.16221435 0.69074402 625.75 2.61365152e+00 7.15709048e-02 2.61463127e+00 0.02737665 0.71298488 626.00 2.38338839e+00 -5.08361305e-02 2.38393048e+00 -0.02132612 0.80598691 626.25 1.86471587e+00 -1.36372267e-01 1.86969588e+00 -0.07300303 0.78224538 626.50 1.54580515e+00 -2.06780324e-01 1.55957420e+00 -0.13297926 0.80280800 626.75 1.17644911e+00 -1.62490810e-01 1.18761768e+00 -0.13725132 0.78126881 627.00 9.82032596e-01 -1.35410046e-01 9.91324317e-01 -0.13702348 0.81255177 627.25 7.06195791e-01 -9.63081288e-02 7.12732594e-01 -0.13553981 0.79187965 627.50 6.02361698e-01 -9.77887753e-02 6.10247704e-01 -0.16093824 0.77244762 627.75 3.45223470e-01 3.09245298e-02 3.46605786e-01 0.08933984 0.44699699 628.00 1.47053835e-01 1.02128118e-01 1.79039054e-01 0.60702161 0.20479600 628.25 -6.62163799e-02 2.64495755e-01 2.72658419e-01 1.81610390 0.44410079 628.50 -1.33306062e-01 4.21581039e-01 4.42155039e-01 1.87705306 0.77522544 628.75 -1.49976030e-01 6.50582621e-01 6.67645532e-01 1.79736397 0.86286424 629.00 -9.27026116e-02 7.98197611e-01 8.03562817e-01 1.68641825 0.89717520 629.25 -1.72840907e-02 8.63098799e-01 8.63271844e-01 1.59081927 0.91936088 629.50 5.08010934e-02 8.49838397e-01 8.51355420e-01 1.51109002 0.90161053 629.75 1.75828084e-01 7.77883027e-01 7.97507065e-01 1.34849784 0.91433754 630.00 1.52905843e-01 7.57574604e-01 7.72851523e-01 1.37163599 0.93125492 630.25 1.52645223e-01 7.45670291e-01 7.61133856e-01 1.36887726 0.91553104 630.50 1.46989362e-01 7.29082496e-01 7.43752081e-01 1.37185444 0.91613863 630.75 7.71770101e-02 6.85171080e-01 6.89503952e-01 1.45863007 0.90524769 631.00 4.63906760e-02 6.58920730e-01 6.60551757e-01 1.50050827 0.87338658 631.25 4.31026919e-02 5.80523223e-01 5.82121169e-01 1.49668431 0.83904529 631.50 6.60132167e-02 5.69854027e-01 5.73664848e-01 1.45546805 0.84027091 631.75 3.51717296e-02 5.37207289e-01 5.38357429e-01 1.50541820 0.82791302 632.00 9.76326221e-03 5.06181879e-01 5.06276027e-01 1.55151067 0.82942621 632.25 -4.74535179e-02 4.63724624e-01 4.66146289e-01 1.67277261 0.80584942 632.50 -9.48544121e-02 4.47445060e-01 4.57388720e-01 1.77969485 0.77663827 632.75 -2.19705146e-01 4.37964364e-01 4.89982791e-01 2.03576365 0.80262106 633.00 -3.15810866e-01 4.21756585e-01 5.26891943e-01 2.21352829 0.78515860 633.25 -4.09103394e-01 3.66620680e-01 5.49341706e-01 2.41090508 0.76779357 633.50 -4.53429790e-01 3.98859712e-01 6.03893736e-01 2.42013484 0.75855341 633.75 -5.93776676e-01 4.12980389e-01 7.23272799e-01 2.53388333 0.80821857 634.00 -6.62632150e-01 4.25775349e-01 7.87633172e-01 2.57047140 0.81865978 634.25 -8.04129157e-01 4.80617046e-01 9.36811852e-01 2.60287608 0.86888023 634.50 -9.81927141e-01 4.45724067e-01 1.07835563e+00 2.71547714 0.84634642 634.75 -1.18193884e+00 3.14647546e-01 1.22310364e+00 2.88141381 0.86196546 635.00 -1.41520733e+00 4.25630361e-01 1.47782712e+00 2.84944355 0.78873200 635.25 -1.90027765e+00 8.73462375e-01 2.09140901e+00 2.71074293 0.72545102 635.50 -1.53572325e+00 1.13985158e+00 1.91251341e+00 2.50308640 0.57709561 635.75 -1.25801999e+00 1.51806673e+00 1.97158335e+00 2.26279319 0.56809639 636.00 -7.21304685e-01 1.61704329e+00 1.77062403e+00 1.99037220 0.50345104 636.25 -5.60143608e-01 1.55261860e+00 1.65057123e+00 1.91703647 0.43338502 636.50 -9.22489982e-01 1.40038886e+00 1.67692478e+00 2.15329006 0.43590351 636.75 -9.23097534e-01 1.25016671e+00 1.55403535e+00 2.20681877 0.35657737 637.00 -4.37418038e-01 8.26938048e-01 9.35500441e-01 2.05734347 0.13366299 637.25 2.21941623e-01 6.63177204e-01 6.99329742e-01 1.24784853 0.06112059 637.50 5.79948950e-01 8.38618233e-01 1.01961823e+00 0.96576202 0.11558027 637.75 1.54592056e+00 9.57134290e-01 1.81823443e+00 0.55437102 0.29462850 638.00 2.09079465e+00 6.56063677e-01 2.19131052e+00 0.30405672 0.52742555 638.25 2.39571290e+00 4.57738574e-01 2.43905000e+00 0.18879032 0.67990286 638.50 2.40591483e+00 2.27934801e-01 2.41668791e+00 0.09445742 0.72968122 638.75 2.27577565e+00 -3.81163010e-03 2.27577884e+00 -0.00167487 0.72636514 639.00 1.70008536e+00 -4.58307007e-01 1.76077697e+00 -0.26331923 0.69888341 639.25 1.55712223e+00 -6.80342770e-01 1.69926335e+00 -0.41192617 0.78077734 639.50 1.03578700e+00 -8.84753428e-01 1.36222000e+00 -0.70691850 0.77011386 639.75 8.93897001e-01 -8.67905124e-01 1.24591780e+00 -0.77064623 0.77767765 640.00 3.78002683e-01 -9.31390697e-01 1.00517394e+00 -1.18525910 0.64448304 640.25 1.33180288e-01 -9.17871075e-01 9.27482776e-01 -1.42670496 0.68123062 640.50 -3.31506712e-01 -6.83866309e-01 7.59980150e-01 -2.02217266 0.58286212 640.75 -4.51814202e-01 -6.29295634e-01 7.74692886e-01 -2.19347992 0.61059316 641.00 -6.76280390e-01 -4.87439032e-01 8.33637797e-01 -2.51706616 0.47842284 641.25 -7.68525322e-01 -2.44629827e-01 8.06520256e-01 -2.83342285 0.48521581 641.50 -8.49461251e-01 9.20323927e-02 8.54432196e-01 3.03367153 0.51903049 641.75 -7.94059783e-01 3.72033213e-01 8.76892041e-01 2.70344434 0.45807475 642.00 -6.15033268e-01 5.87060957e-01 8.50239077e-01 2.37945994 0.45881609 642.25 -6.89799257e-01 6.32665218e-01 9.35995883e-01 2.39937034 0.48874486 642.50 -3.82040536e-01 6.50311942e-01 7.54228476e-01 2.10195368 0.34712211 642.75 -3.19250589e-01 4.03720723e-01 5.14695405e-01 2.23988436 0.20486919 643.00 -4.10729230e-01 6.82032365e-02 4.16353434e-01 2.97704013 0.13106225 643.25 -7.99280695e-01 -1.84944673e-01 8.20398782e-01 -2.91420556 0.36504211 643.50 -1.07865475e+00 -1.50819650e-01 1.08914767e+00 -3.00267131 0.57138310 643.75 -1.29920104e+00 -2.86915926e-02 1.29951782e+00 -3.11951221 0.58136983 644.00 -1.62396253e+00 -3.80760041e-03 1.62396699e+00 -3.13924802 0.68856577 644.25 -1.77377079e+00 1.26360499e-02 1.77381580e+00 3.13446894 0.69837274 644.50 -2.10584921e+00 2.36608849e-01 2.11909996e+00 3.02970399 0.78696982 644.75 -2.34642258e+00 1.60726558e-02 2.34647763e+00 3.13474291 0.72400394 645.00 -2.55940125e+00 -3.49859490e-01 2.58320274e+00 -3.00573882 0.57801730 645.25 -2.94893417e+00 -2.32494574e-01 2.95808493e+00 -3.06291519 0.41617218 645.50 -3.55437256e+00 1.66017878e+00 3.92297819e+00 2.70462557 0.40132070 645.75 -3.15644214e+00 1.87121845e+00 3.66941214e+00 2.60646544 0.39454750 646.00 -3.78913112e+00 2.00764822e+00 4.28814249e+00 2.65435591 0.39046197 646.25 -2.98426451e+00 2.62510554e+00 3.97454573e+00 2.42013560 0.27017369 646.50 -2.41417450e+00 4.37502074e+00 4.99690354e+00 2.07502711 0.22723115 646.75 -2.71771358e-01 3.07556034e+00 3.08754450e+00 1.65893223 0.07597776 647.00 2.01744623e+00 1.71358233e+00 2.64697066e+00 0.70413512 0.05238585 647.25 3.31441324e+00 1.56961035e+00 3.66728943e+00 0.44228184 0.14153389 647.50 4.17598425e+00 3.56634106e-01 4.19118508e+00 0.08519449 0.23844320 647.75 3.25506637e+00 -7.76788003e-01 3.34646929e+00 -0.23425835 0.29230232 648.00 3.12424420e+00 -8.38150214e-01 3.23471754e+00 -0.26210144 0.38068266 648.25 2.56103458e+00 -9.00118723e-01 2.71461081e+00 -0.33798098 0.40637415 648.50 2.51619659e+00 -6.86119402e-01 2.60806539e+00 -0.26620913 0.47480033 648.75 2.53003678e+00 -1.13874014e+00 2.77449369e+00 -0.42292742 0.53790126 649.00 2.21278369e+00 -1.53528243e+00 2.69323296e+00 -0.60656896 0.62289115 649.25 1.43135091e+00 -1.73523501e+00 2.24940125e+00 -0.88107103 0.60096827 649.50 1.13257264e+00 -1.69773723e+00 2.04084112e+00 -0.98248884 0.61417580 649.75 3.16107553e-01 -1.56963253e+00 1.60114655e+00 -1.37206504 0.62008498 650.00 4.86389826e-02 -1.45846299e+00 1.45927381e+00 -1.53745920 0.64281806 650.25 -4.33144649e-01 -1.10059836e+00 1.18276415e+00 -1.94573330 0.68324995 650.50 -5.14574985e-01 -9.99418920e-01 1.12411102e+00 -2.04627234 0.73399260 650.75 -7.92088361e-01 -9.55442006e-01 1.24107752e+00 -2.26298848 0.69798651 651.00 -1.03220894e+00 -9.67619439e-01 1.41482955e+00 -2.38848079 0.70453929 651.25 -1.47980397e+00 -8.28032674e-01 1.69571752e+00 -2.63144266 0.83432979 651.50 -1.76666566e+00 -6.73080517e-01 1.89054091e+00 -2.77758155 0.86099936 651.75 -2.16739204e+00 -2.76712870e-01 2.18498473e+00 -3.01460873 0.84534526 652.00 -2.37705284e+00 -1.10355057e-01 2.37961309e+00 -3.09520080 0.86443243 652.25 -2.48406603e+00 1.68634092e-01 2.48978343e+00 3.07381034 0.88870234 652.50 -2.62864786e+00 1.53850553e-01 2.63314633e+00 3.08313095 0.90235695 652.75 -2.89531357e+00 1.91427008e-01 2.90163488e+00 3.07557258 0.92772967 653.00 -3.16186161e+00 4.33124859e-01 3.19138935e+00 3.00545583 0.91826386 653.25 -3.83230329e+00 7.95213942e-01 3.91393839e+00 2.93699331 0.92878683 653.50 -3.76259680e+00 1.47950823e+00 4.04302847e+00 2.76694936 0.87995317 653.75 -3.13918693e+00 2.75623928e+00 4.17748124e+00 2.42106010 0.88158789 654.00 -2.29727468e+00 3.06750876e+00 3.83237276e+00 2.21359669 0.85544536 654.25 -1.41066739e+00 3.02929440e+00 3.34164735e+00 2.00660905 0.89550333 654.50 -9.03762857e-01 2.31612902e+00 2.48621015e+00 1.94282947 0.77817253 654.75 -4.33663134e-01 1.52639244e+00 1.58680106e+00 1.84761202 0.81368609 655.00 -2.10467280e-01 1.09551304e+00 1.11554708e+00 1.76060125 0.53074129 655.25 2.45855155e-01 3.11854663e-01 3.97112185e-01 0.90319056 0.14000711 655.50 4.97720324e-01 -3.74609468e-01 6.22942834e-01 -0.64519529 0.16055184 655.75 3.14779341e-01 -1.55727965e+00 1.58877499e+00 -1.37134958 0.52907411 656.00 -5.37303081e-01 -2.39975019e+00 2.45916562e+00 -1.79106314 0.67588883 656.25 -1.15581573e+00 -3.05682556e+00 3.26804108e+00 -1.93229061 0.87406896 656.50 -1.51834187e+00 -3.14746164e+00 3.49454958e+00 -2.02026670 0.85198695 656.75 -1.67098147e+00 -3.10172411e+00 3.52319054e+00 -2.06494320 0.87645831 657.00 -1.80093670e+00 -3.56180510e+00 3.99121893e+00 -2.03893358 0.87088661 657.25 -1.65352496e+00 -3.82020904e+00 4.16270849e+00 -1.97928558 0.86346616 657.50 -1.11465994e+00 -4.68172158e+00 4.81258597e+00 -1.80453230 0.80086231 657.75 -1.03873737e+00 -5.58777664e+00 5.68350447e+00 -1.75459293 0.80552165 658.00 -1.18252954e+00 -8.29495906e+00 8.37882581e+00 -1.71240219 0.86269811 658.25 -1.59074478e+00 -9.99687569e+00 1.01226475e+01 -1.72859753 0.93214605 658.50 -3.81087788e+00 -1.15271689e+01 1.21407748e+01 -1.89008454 0.93806461 658.75 -5.17404534e+00 -1.24271374e+01 1.34612217e+01 -1.96531805 0.96004550 659.00 -6.57497816e+00 -1.32879927e+01 1.48256901e+01 -2.03028009 0.96776916 659.25 -7.68302966e+00 -1.38085805e+01 1.58020834e+01 -2.07853632 0.96173237 659.50 -9.60369028e+00 -1.50236493e+01 1.78308975e+01 -2.13956888 0.95785346 659.75 -1.04369399e+01 -1.56400398e+01 1.88026743e+01 -2.15925236 0.95611583 660.00 -1.29596508e+01 -1.58008915e+01 2.04357707e+01 -2.25772446 0.94175136 660.25 -1.44244805e+01 -1.61586197e+01 2.16602546e+01 -2.29955261 0.94041945 660.50 -1.82913302e+01 -1.46940674e+01 2.34624887e+01 -2.46482142 0.92978601 660.75 -1.94513956e+01 -1.40163307e+01 2.39752855e+01 -2.51718623 0.93910975 661.00 -2.15919621e+01 -1.33670708e+01 2.53947123e+01 -2.58726446 0.92686797 661.25 -2.19673351e+01 -1.27231641e+01 2.53858763e+01 -2.61661848 0.91136963 661.50 -2.24737611e+01 -1.40658126e+01 2.65125823e+01 -2.58236286 0.89228000 661.75 -2.45487869e+01 -1.41994847e+01 2.83596245e+01 -2.61719270 0.90021543 662.00 -3.30082811e+01 -1.11924751e+01 3.48542411e+01 -2.81467831 0.87505442 662.25 -3.56705380e+01 -9.40185643e+00 3.68887813e+01 -2.88387904 0.88816069 662.50 -3.69528253e+01 -1.83163006e-02 3.69528299e+01 -3.14109699 0.83074069 662.75 -3.57093440e+01 4.45588397e+00 3.59862772e+01 3.01745229 0.85327019 663.00 -3.24717340e+01 7.12569298e+00 3.32443831e+01 2.92557375 0.89975998 663.25 -3.06842445e+01 7.84651097e+00 3.16716055e+01 2.89123971 0.91883008 663.50 -2.89430536e+01 8.41303176e+00 3.01409929e+01 2.85871240 0.94831181 663.75 -2.80538777e+01 8.10325961e+00 2.92007341e+01 2.86039973 0.95598668 664.00 -2.84421594e+01 7.42290493e+00 2.93948286e+01 2.88630456 0.96264398 664.25 -2.87652732e+01 7.48498784e+00 2.97231557e+01 2.88702868 0.94843046 664.50 -2.95625650e+01 4.98189620e+00 2.99794019e+01 2.97464086 0.90534010 664.75 -2.90895893e+01 3.14337905e+00 2.92589309e+01 3.03395176 0.81194982 665.00 -2.14914456e+01 1.20856900e+00 2.15254006e+01 3.08541693 0.43016580 665.25 -9.29797451e+00 7.91102809e+00 1.22080586e+01 2.43661491 0.21266097 665.50 -3.70908641e+00 1.18109518e+01 1.23796568e+01 1.87508165 0.48151793 665.75 -5.24551732e+00 9.60614255e+00 1.09450183e+01 2.07060852 0.56438345 666.00 -8.01746647e+00 8.60069515e+00 1.17580494e+01 2.32111303 0.82237900 666.25 -1.15752216e+01 6.55736527e+00 1.33035632e+01 2.62616967 0.84507631 666.50 -1.40060131e+01 6.24082991e+00 1.53335045e+01 2.72241865 0.92272942 666.75 -1.64377356e+01 8.13786248e+00 1.83418635e+01 2.68189522 0.92797533 667.00 -1.86446196e+01 8.81029922e+00 2.06214260e+01 2.70015465 0.96094994 667.25 -1.91709182e+01 1.09557751e+01 2.20806049e+01 2.62240860 0.96132920 667.50 -1.93255678e+01 1.27160463e+01 2.31338584e+01 2.55962048 0.97418712 667.75 -1.82509918e+01 1.37502308e+01 2.28509858e+01 2.49592142 0.94958896 668.00 -1.76811469e+01 1.54451560e+01 2.34771335e+01 2.42359122 0.93515321 668.25 -1.73907549e+01 1.65199906e+01 2.39864221e+01 2.38186697 0.91300282 668.50 -1.67521731e+01 1.95687530e+01 2.57598796e+01 2.27880235 0.92369050 668.75 -1.57245515e+01 2.09367650e+01 2.61841488e+01 2.21496892 0.88757387 669.00 -1.42626811e+01 2.24748885e+01 2.66185027e+01 2.13627296 0.85866118 669.25 -8.19808870e+00 2.53835173e+01 2.66745499e+01 1.88319014 0.78518006 669.50 -5.11908764e+00 2.75409257e+01 2.80126337e+01 1.75457113 0.81491109 669.75 4.38961427e-01 2.82328164e+01 2.82362287e+01 1.55524966 0.82303178 670.00 5.16191157e+00 2.58837193e+01 2.63934132e+01 1.37395182 0.84996796 670.25 5.02872063e+00 1.98348333e+01 2.04623714e+01 1.32249830 0.88747054 670.50 4.84757542e+00 1.85066531e+01 1.91310009e+01 1.31461486 0.92262646 670.75 4.34011243e+00 1.71496284e+01 1.76902892e+01 1.32292728 0.92903269 671.00 3.96502541e+00 1.61219290e+01 1.66023499e+01 1.32964258 0.91478643 671.25 4.64537132e+00 1.35621242e+01 1.43356440e+01 1.24079590 0.88757095 671.50 5.49711944e+00 1.31589593e+01 1.42610144e+01 1.17508480 0.89475498 671.75 4.91817943e+00 1.14403172e+01 1.24526843e+01 1.16478362 0.90713102 672.00 4.73325508e+00 1.04482673e+01 1.14703964e+01 1.14543531 0.90563840 672.25 4.69766582e+00 8.31835644e+00 9.55317319e+00 1.05671079 0.87167216 672.50 4.55999360e+00 6.97507720e+00 8.33338128e+00 0.99178571 0.84173794 672.75 3.66864168e+00 5.00362384e+00 6.20444867e+00 0.93813619 0.74279634 673.00 2.95946903e+00 3.97720243e+00 4.95747881e+00 0.93107663 0.65033632 673.25 1.65920969e+00 4.15614688e+00 4.47510152e+00 1.19096405 0.50714511 673.50 1.00933604e+00 4.70134194e+00 4.80846912e+00 1.35931549 0.53685593 673.75 1.63997953e+00 4.70667857e+00 4.98421067e+00 1.23551488 0.57672728 674.00 1.90498136e+00 4.06728779e+00 4.49130092e+00 1.13277423 0.54300913 674.25 7.34724993e-01 2.98518119e+00 3.07426862e+00 1.32946890 0.34598070 674.50 2.36876497e-01 1.48478537e+00 1.50356179e+00 1.41259366 0.08941110 674.75 2.01286566e-01 4.29828679e-01 4.74625089e-01 1.13283297 0.01067196 675.00 -7.06928736e-01 -2.95544402e-01 7.66221072e-01 -2.74560795 0.03147897 675.25 -2.42404543e+00 -1.08449171e+00 2.65558252e+00 -2.72091200 0.23441115 675.50 -3.86320180e+00 -1.71913351e+00 4.22844512e+00 -2.72290262 0.46568830 675.75 -4.64780283e+00 -1.52621373e+00 4.89197296e+00 -2.82431287 0.56992127 676.00 -5.72933538e+00 -1.27334243e+00 5.86912982e+00 -2.92289763 0.56082862 676.25 -7.32504458e+00 -1.82817712e+00 7.54973573e+00 -2.89701029 0.69056211 676.50 -9.20058116e+00 -1.22113133e+00 9.28126368e+00 -3.00964056 0.79345039 676.75 -1.07767499e+01 -8.48087363e-01 1.08100689e+01 -3.06305849 0.83421484 677.00 -1.18100791e+01 4.73519135e-02 1.18101741e+01 3.13758323 0.82936379 677.25 -1.23354813e+01 1.25175967e+00 1.23988306e+01 3.04046248 0.85593203 677.50 -1.29949471e+01 2.38385403e+00 1.32117906e+01 2.96016515 0.88498716 677.75 -1.36545753e+01 3.74168471e+00 1.41579529e+01 2.87413382 0.91752504 678.00 -1.48291876e+01 5.25144029e+00 1.57315743e+01 2.80124449 0.91473491 678.25 -1.57879967e+01 6.67311901e+00 1.71403430e+01 2.74169685 0.93354219 678.50 -1.44310153e+01 8.91631602e+00 1.69633397e+01 2.58814576 0.90892210 678.75 -1.44129356e+01 1.10193531e+01 1.81427356e+01 2.48884688 0.90417792 679.00 -1.30845939e+01 1.39754222e+01 1.91446866e+01 2.32328591 0.91314333 679.25 -1.23200453e+01 1.51195456e+01 1.95034401e+01 2.25452216 0.93755089 679.50 -1.14957455e+01 1.72025378e+01 2.06900815e+01 2.15990030 0.94374526 679.75 -1.02937852e+01 1.82863912e+01 2.09846162e+01 2.08350519 0.93694633 680.00 -7.19733963e+00 2.12472712e+01 2.24331948e+01 1.89740661 0.93320377 680.25 -4.81279845e+00 2.20398735e+01 2.25592343e+01 1.78578924 0.93939377 680.50 -1.24390806e+00 1.95315109e+01 1.95710813e+01 1.63439767 0.85745090 680.75 2.58290790e+00 1.79010932e+01 1.80864742e+01 1.42749759 0.84923539 681.00 4.83337199e+00 1.52607063e+01 1.60078306e+01 1.26407147 0.92880858 681.25 5.63680578e+00 1.53101807e+01 1.63148770e+01 1.21802375 0.94549902 681.50 5.95592659e+00 1.45713662e+01 1.57415938e+01 1.18277670 0.94390548 681.75 6.03180290e+00 1.41236146e+01 1.53577061e+01 1.16717183 0.92689394 682.00 6.67591208e+00 1.32970041e+01 1.48787809e+01 1.10550098 0.90383951 682.25 6.93226222e+00 1.35993563e+01 1.52642967e+01 1.09937974 0.91502545 682.50 6.80998309e+00 1.32492135e+01 1.48968966e+01 1.09601827 0.88852105 682.75 7.66238778e+00 1.29316451e+01 1.50312884e+01 1.03588757 0.89852391 683.00 8.58872894e+00 1.28324916e+01 1.54414735e+01 0.98097596 0.93455796 683.25 8.59043061e+00 1.37473240e+01 1.62106267e+01 1.01228316 0.92434957 683.50 1.27730673e+01 1.39978642e+01 1.89497084e+01 0.83111729 0.86782337 683.75 1.61843750e+01 1.22147451e+01 2.02764393e+01 0.64651797 0.85464299 684.00 1.83848626e+01 8.06919994e+00 2.00777280e+01 0.41358874 0.88531157 684.25 1.96754465e+01 6.33954038e+00 2.06715497e+01 0.31170245 0.86371930 684.50 1.94397939e+01 1.74054251e+00 1.95175582e+01 0.08929692 0.79101317 684.75 1.81150026e+01 -2.69482555e+00 1.83143497e+01 -0.14767905 0.80994826 685.00 1.46530413e+01 -8.56262740e+00 1.69714527e+01 -0.52883891 0.85886569 685.25 1.18966499e+01 -8.55141490e+00 1.46511766e+01 -0.62323800 0.82863686 685.50 9.56579654e+00 -7.79048921e+00 1.23367818e+01 -0.68346653 0.87572283 685.75 8.57566084e+00 -7.59943127e+00 1.14583295e+01 -0.72511741 0.86951362 686.00 7.44291544e+00 -7.61861398e+00 1.06508342e+01 -0.79706302 0.89096455 686.25 6.60637455e+00 -7.44162976e+00 9.95098178e+00 -0.84478546 0.86801074 686.50 5.72784506e+00 -7.94549858e+00 9.79485358e+00 -0.94618617 0.91473433 686.75 4.81194844e+00 -8.10303296e+00 9.42411752e+00 -1.03491460 0.90155867 687.00 3.56855268e+00 -8.37928342e+00 9.10752210e+00 -1.16818222 0.93912199 687.25 2.65613640e+00 -8.36759781e+00 8.77905198e+00 -1.26342533 0.91421824 687.50 1.68385772e+00 -8.41662341e+00 8.58340995e+00 -1.37333987 0.93883048 687.75 1.02120654e+00 -7.53853605e+00 7.60739039e+00 -1.43615111 0.91632862 688.00 4.54165009e-01 -6.93218052e+00 6.94704200e+00 -1.50537436 0.93557847 688.25 2.47697600e-02 -6.57542638e+00 6.57547303e+00 -1.56702933 0.90682808 688.50 -1.15491187e-01 -6.23364574e+00 6.23471550e+00 -1.58932128 0.92536327 688.75 -4.79434243e-01 -5.59182987e+00 5.61234518e+00 -1.65632551 0.89251434 689.00 -6.00153692e-01 -5.46204221e+00 5.49491489e+00 -1.68023448 0.90594423 689.25 -3.10198826e-01 -5.30718085e+00 5.31623851e+00 -1.62917879 0.85238257 689.50 -8.07778102e-02 -5.52547570e+00 5.52606612e+00 -1.58541444 0.85701826 689.75 4.17951116e-01 -5.84501567e+00 5.85993953e+00 -1.49941227 0.68796540 690.00 2.75297332e-01 -4.49913575e+00 4.50755046e+00 -1.50968358 0.34648021 690.25 -2.77688660e+00 -6.33378414e-01 2.84820424e+00 -2.91733962 0.33305619 690.50 -3.35577277e+00 -1.06393130e+00 3.52039213e+00 -2.83457243 0.64058601 690.75 -3.05939440e+00 -1.98744827e+00 3.64826598e+00 -2.56548359 0.81013663 691.00 -3.20310745e+00 -2.19642356e+00 3.88383493e+00 -2.54051741 0.86744372 691.25 -3.64334502e+00 -2.23066511e+00 4.27198195e+00 -2.59220904 0.88345715 691.50 -3.93499430e+00 -2.14433153e+00 4.48133215e+00 -2.64264341 0.90797754 691.75 -3.77074957e+00 -2.42152177e+00 4.48133015e+00 -2.57073036 0.89834530 692.00 -4.05651276e+00 -2.52738703e+00 4.77943312e+00 -2.58440094 0.90654294 692.25 -4.60989432e+00 -2.18931382e+00 5.10335386e+00 -2.69821264 0.90689685 692.50 -4.78990568e+00 -1.93903752e+00 5.16750065e+00 -2.75694019 0.88017347 692.75 -5.36908614e+00 -1.48630362e+00 5.57101287e+00 -2.87152945 0.79355702 693.00 -5.88578995e+00 -1.37547834e+00 6.04437457e+00 -2.91201797 0.76401116 693.25 -6.36741655e+00 -6.53607668e-01 6.40087467e+00 -3.03930212 0.70537072 693.50 -6.89341029e+00 -2.33061210e-01 6.89734898e+00 -3.10779625 0.71215846 693.75 -7.91351046e+00 1.26191873e+00 8.01349404e+00 2.98346022 0.76724720 694.00 -7.77156205e+00 1.98511468e+00 8.02108827e+00 2.89150700 0.68150056 694.25 -6.98359930e+00 4.36305172e+00 8.23449328e+00 2.58316818 0.70596347 694.50 -7.03743352e+00 5.05878910e+00 8.66699589e+00 2.51833395 0.72528194 694.75 -7.44498560e+00 5.74858888e+00 9.40606637e+00 2.48407037 0.76806132 695.00 -6.30678316e+00 6.09700719e+00 8.77205851e+00 2.37310513 0.70091192 695.25 -4.92994951e+00 5.23982364e+00 7.19445299e+00 2.32573380 0.66104346 695.50 -4.32666992e+00 6.41462438e+00 7.73740774e+00 2.16420304 0.70977028 695.75 -4.06902841e+00 7.76561299e+00 8.76708260e+00 2.05344364 0.73153963 696.00 -4.03485304e+00 6.89545778e+00 7.98920378e+00 2.10022254 0.58266568 696.25 -3.11310183e+00 5.81217358e+00 6.59338796e+00 2.06253029 0.47102323 696.50 -3.06606710e+00 5.35248557e+00 6.16845761e+00 2.09099866 0.48686748 696.75 -4.25647210e+00 5.41724495e+00 6.88941925e+00 2.23677302 0.49854623 697.00 -5.02829073e+00 6.45200810e+00 8.17998266e+00 2.23281048 0.50085486 697.25 -6.38117903e+00 6.72312669e+00 9.26929761e+00 2.33010611 0.50856527 697.50 -7.34242054e+00 5.30300840e+00 9.05720915e+00 2.51609427 0.51825026 697.75 -7.43863999e+00 5.70238437e+00 9.37286255e+00 2.48755844 0.43850359 698.00 -6.53997962e+00 6.65330206e+00 9.32940308e+00 2.34760530 0.36167765 698.25 -5.11976797e+00 7.63810920e+00 9.19525618e+00 2.16130498 0.28190993 698.50 -4.68498819e+00 5.74292996e+00 7.41150180e+00 2.25508760 0.21290978 698.75 -3.42786231e+00 4.35133070e+00 5.53934282e+00 2.23803740 0.13094028 699.00 -5.01990827e+00 3.14245662e+00 5.92237390e+00 2.58227541 0.16369166 699.25 -3.60741456e+00 2.77416664e+00 4.55076261e+00 2.48603073 0.10080802 699.50 -1.03294509e+00 1.34654646e+00 1.69710427e+00 2.22515626 0.02171521 699.75 -1.11756531e-01 -1.08017169e+00 1.08593756e+00 -1.67389134 0.00884827 700.00 2.43246702e+00 -8.80730874e-01 2.58700264e+00 -0.34738962 0.05882923 700.25 4.30365595e+00 3.92725599e-01 4.32153768e+00 0.09100191 0.13485410 700.50 5.95372321e+00 4.05962121e-01 5.96754768e+00 0.06808088 0.24318013 700.75 7.64718241e+00 1.14634441e+00 7.73262597e+00 0.14879621 0.32056736 701.00 8.35466704e+00 1.85312652e+00 8.55771811e+00 0.21827356 0.30962728 701.25 8.44077318e+00 2.58515971e+00 8.82778016e+00 0.29719956 0.32965119 701.50 7.45527356e+00 3.61658488e+00 8.28618067e+00 0.45166015 0.34543406 701.75 6.49218693e+00 3.81723746e+00 7.53125440e+00 0.53152996 0.28698194 702.00 4.40505570e+00 5.05924761e+00 6.70824136e+00 0.85441043 0.20030895 702.25 1.80180034e+00 5.12649336e+00 5.43391375e+00 1.23281397 0.16081615 702.50 1.01530924e+00 3.76125756e+00 3.89588389e+00 1.30714156 0.11131322 702.75 1.32994648e+00 2.23934163e+00 2.60449776e+00 1.03487370 0.06893002 703.00 6.27098513e-01 2.97565646e+00 3.04101692e+00 1.36309270 0.13712968 703.25 7.75689752e-02 1.76045824e+00 1.76216633e+00 1.52676300 0.04837968 703.50 2.21803052e+00 2.76181397e-01 2.23515895e+00 0.12387890 0.05715113 703.75 3.35698550e+00 -2.30596705e-01 3.36489621e+00 -0.06858386 0.09797521 704.00 2.60209060e+00 -2.74615374e+00 3.78315158e+00 -0.81232818 0.09165711 704.25 2.53238903e+00 -5.22985212e+00 5.81070972e+00 -1.11985377 0.17453729 704.50 4.55426976e+00 -8.18367485e+00 9.36557030e+00 -1.06297131 0.43313297 704.75 4.09436177e+00 -8.32894291e+00 9.28089911e+00 -1.11390544 0.49354856 705.00 5.59530296e+00 -7.91089917e+00 9.68967186e+00 -0.95519422 0.62109551 705.25 7.13691985e+00 -7.40768554e+00 1.02863711e+01 -0.80401224 0.66122623 705.50 8.28255240e+00 -7.45189285e+00 1.11414264e+01 -0.73265470 0.74176855 705.75 8.02192371e+00 -7.64156018e+00 1.10790208e+01 -0.76111948 0.75048097 706.00 9.02580143e+00 -7.74070343e+00 1.18904828e+01 -0.70890099 0.79196028 706.25 9.43008789e+00 -6.01799457e+00 1.11867250e+01 -0.56801352 0.78234648 706.50 1.01068788e+01 -5.20251552e+00 1.13672849e+01 -0.47537783 0.81898437 706.75 1.04388900e+01 -5.02818500e+00 1.15867627e+01 -0.44888297 0.81110086 707.00 1.10626052e+01 -5.01218140e+00 1.21450894e+01 -0.42540752 0.86828556 707.25 1.18195553e+01 -4.50572372e+00 1.26492464e+01 -0.36420325 0.89073116 707.50 1.29220693e+01 -4.00011553e+00 1.35270395e+01 -0.30020136 0.93550532 707.75 1.34868098e+01 -3.52962961e+00 1.39410303e+01 -0.25596888 0.91721472 708.00 1.46184012e+01 -3.66282606e+00 1.50703002e+01 -0.24550819 0.92459894 708.25 1.48564399e+01 -3.86522060e+00 1.53510175e+01 -0.25452859 0.91512313 708.50 1.54750007e+01 -3.84612847e+00 1.59457942e+01 -0.24360236 0.90782033 708.75 1.61686730e+01 -5.11257589e+00 1.69577244e+01 -0.30625446 0.88381134 709.00 1.66560451e+01 -6.35326276e+00 1.78266033e+01 -0.36440371 0.90014774 709.25 1.64719143e+01 -7.64615617e+00 1.81600568e+01 -0.43459438 0.90192841 709.50 1.69166990e+01 -9.02291219e+00 1.91725755e+01 -0.48998829 0.91890938 709.75 1.59374287e+01 -1.02049799e+01 1.89246730e+01 -0.56953686 0.90464767 710.00 1.55603317e+01 -1.07332356e+01 1.89030757e+01 -0.60383523 0.93406820 710.25 1.42065392e+01 -1.16798976e+01 1.83914590e+01 -0.68810151 0.92120976 710.50 1.38645932e+01 -1.24550814e+01 1.86374890e+01 -0.73189573 0.92445044 710.75 1.18468641e+01 -1.24268120e+01 1.71689791e+01 -0.80928567 0.93376452 711.00 1.13004773e+01 -1.27560527e+01 1.70416451e+01 -0.84583094 0.95138822 711.25 9.89519527e+00 -1.32839236e+01 1.65643447e+01 -0.93056719 0.94435732 711.50 8.77028846e+00 -1.36658812e+01 1.62380500e+01 -1.00023179 0.95203604 711.75 7.58111685e+00 -1.28392506e+01 1.49103886e+01 -1.03741801 0.96652778 712.00 6.92476412e+00 -1.22358520e+01 1.40594606e+01 -1.05579716 0.96517815 712.25 5.19662756e+00 -1.08806005e+01 1.20578774e+01 -1.12522482 0.94484688 712.50 4.33149040e+00 -1.02437551e+01 1.11218851e+01 -1.17075490 0.94056907 712.75 3.38963279e+00 -8.96328878e+00 9.58280524e+00 -1.20925076 0.94915363 713.00 2.93702960e+00 -8.07861207e+00 8.59593601e+00 -1.22209612 0.95154943 713.25 2.29762023e+00 -6.63255784e+00 7.01925083e+00 -1.23731847 0.92988787 713.50 2.25845016e+00 -6.11859276e+00 6.52209893e+00 -1.21719711 0.92598790 713.75 1.94832375e+00 -4.99683868e+00 5.36324176e+00 -1.19901727 0.92714918 714.00 1.77981259e+00 -4.46319950e+00 4.80498519e+00 -1.19134639 0.91222560 714.25 2.04747096e+00 -3.32156953e+00 3.90191766e+00 -1.01839309 0.92573038 714.50 2.06736309e+00 -2.89023074e+00 3.55350867e+00 -0.94987988 0.91834683 714.75 2.18552924e+00 -2.09415514e+00 3.02688351e+00 -0.76405075 0.94668807 715.00 2.30833887e+00 -1.89902239e+00 2.98909926e+00 -0.68841756 0.94315791 715.25 2.62915823e+00 -1.30060385e+00 2.93326497e+00 -0.45938618 0.95755699 715.50 2.65593738e+00 -1.11167661e+00 2.87920619e+00 -0.39640568 0.96109802 715.75 2.73988103e+00 -8.72248878e-01 2.87537235e+00 -0.30820806 0.97378661 716.00 2.74600164e+00 -7.53759664e-01 2.84757417e+00 -0.26789528 0.97757759 716.25 2.73576672e+00 -5.56547582e-01 2.79180313e+00 -0.20069516 0.97288002 716.50 2.78642690e+00 -3.98342891e-01 2.81475610e+00 -0.14199620 0.96599879 716.75 2.79963775e+00 -1.90942672e-01 2.80614159e+00 -0.06809718 0.97452418 717.00 2.83602437e+00 6.69790888e-03 2.83603228e+00 0.00236172 0.97370160 717.25 2.87569942e+00 2.02213021e-01 2.88280025e+00 0.07020230 0.98168282 717.50 2.90694632e+00 2.78703866e-01 2.92027614e+00 0.09558298 0.98170687 717.75 2.93594663e+00 3.77436348e-01 2.96010824e+00 0.12785568 0.97460325 718.00 3.01669505e+00 4.07236436e-01 3.04405824e+00 0.13418306 0.97285089 718.25 3.12625190e+00 4.06205339e-01 3.15253131e+00 0.12920976 0.98302957 718.50 3.13027103e+00 3.94969338e-01 3.15509073e+00 0.12551407 0.97561427 718.75 3.11043431e+00 4.64556978e-01 3.14493478e+00 0.14825847 0.97179410 719.00 3.06731088e+00 4.11902731e-01 3.09484408e+00 0.13348931 0.97818228 719.25 2.99774239e+00 3.78318047e-01 3.02152015e+00 0.12553733 0.98138681 719.50 2.92342451e+00 4.36195562e-01 2.95578711e+00 0.14811436 0.97644753 719.75 2.90980745e+00 4.90406411e-01 2.95084359e+00 0.16696663 0.97633163 720.00 2.84025065e+00 3.83191185e-01 2.86598312e+00 0.13410482 0.96710186 720.25 2.88342642e+00 1.44152843e-01 2.88702753e+00 0.04995200 0.96908633 720.50 2.80680320e+00 -1.15606368e-01 2.80918298e+00 -0.04116465 0.96421588 720.75 2.61239362e+00 -2.14638098e-01 2.62119628e+00 -0.08197734 0.95457408 721.00 2.06443028e+00 -2.02311873e-01 2.07431976e+00 -0.09768696 0.88212874 721.25 1.67620580e+00 -1.30394351e-01 1.68126993e+00 -0.07763502 0.87884950 721.50 1.47516250e+00 3.78888692e-02 1.47564900e+00 0.02567889 0.84360555 721.75 1.38505814e+00 2.33706724e-01 1.40463692e+00 0.16715969 0.83126332 722.00 1.32583856e+00 5.60933164e-01 1.43961589e+00 0.40024159 0.85180197 722.25 1.25208159e+00 7.48848344e-01 1.45893185e+00 0.53900853 0.87083180 722.50 1.17315133e+00 9.83662154e-01 1.53097200e+00 0.69776709 0.81623051 722.75 1.27560285e+00 1.11707342e+00 1.69558711e+00 0.71923875 0.84069200 723.00 1.28318726e+00 1.56717957e+00 2.02549287e+00 0.88470403 0.86782312 723.25 1.35538767e+00 1.71248511e+00 2.18395993e+00 0.90127575 0.88204886 723.50 1.98992772e+00 1.78676772e+00 2.67438801e+00 0.73165690 0.92405801 723.75 2.22489905e+00 1.70422428e+00 2.80259811e+00 0.65364901 0.94372967 724.00 2.35114270e+00 1.51876276e+00 2.79901988e+00 0.57353550 0.93839289 724.25 2.37776886e+00 1.34629658e+00 2.73245298e+00 0.51519693 0.93447831 724.50 2.29157741e+00 1.07939236e+00 2.53306433e+00 0.44020086 0.90731743 724.75 2.17405436e+00 1.09270961e+00 2.43321324e+00 0.46573642 0.88862104 725.00 2.28584663e+00 1.26258047e+00 2.61136061e+00 0.50464332 0.82034586 725.25 2.70449941e+00 1.31945018e+00 3.00919687e+00 0.45389841 0.82342390 725.50 3.02726925e+00 9.05700980e-01 3.15985022e+00 0.29070511 0.79756056 725.75 3.02683107e+00 5.20072785e-01 3.07118577e+00 0.17015936 0.72271279 726.00 3.12176920e+00 -3.54437198e-01 3.14182569e+00 -0.11305316 0.66851958 726.25 2.68503146e+00 -6.49125344e-01 2.76238260e+00 -0.23720569 0.63965152 726.50 2.23124796e+00 -8.54500811e-01 2.38927585e+00 -0.36573961 0.63150347 726.75 1.87074973e+00 -1.16618430e+00 2.20447054e+00 -0.55743211 0.63909320 727.00 1.32375038e+00 -1.68685996e+00 2.14425082e+00 -0.90542834 0.73762200 727.25 1.02883506e+00 -1.45668018e+00 1.78337285e+00 -0.95586299 0.63050987 727.50 5.40425916e-01 -1.45772807e+00 1.55468045e+00 -1.21577302 0.60879627 727.75 6.36744069e-02 -1.22395953e+00 1.22561469e+00 -1.51881989 0.52123220 728.00 -3.21861818e-01 -8.27597693e-01 8.87982529e-01 -1.94170679 0.43068318 728.25 -3.93166489e-01 -7.08767395e-01 8.10512867e-01 -2.07725508 0.44391003 728.50 -6.08922915e-01 -5.32658794e-01 8.09019472e-01 -2.42290103 0.52105269 728.75 -6.29511253e-01 -3.91462389e-01 7.41301032e-01 -2.58526078 0.47236651 729.00 -7.92405684e-01 -8.73852842e-02 7.97209481e-01 -3.03175800 0.54119431 729.25 -9.39601071e-01 1.61376318e-01 9.53358531e-01 2.97150232 0.54491491 729.50 -9.73416828e-01 5.79535663e-01 1.13287330e+00 2.60459022 0.61133184 729.75 -5.48077368e-01 1.03997249e+00 1.17555586e+00 2.05581883 0.64979387 730.00 -1.60094632e-01 1.21182045e+00 1.22234983e+00 1.70214654 0.73232454 730.25 8.58787561e-02 1.18010067e+00 1.18322135e+00 1.49815199 0.75191798 730.50 2.20170174e-01 1.08643764e+00 1.10852228e+00 1.37085082 0.77007641 730.75 3.85640289e-01 8.52172904e-01 9.35370029e-01 1.14583413 0.70602232 731.00 4.79486959e-01 7.40071212e-01 8.81823760e-01 0.99590373 0.73300736 731.25 4.05326693e-01 6.19386089e-01 7.40222166e-01 0.99133368 0.65053215 731.50 3.56366429e-01 6.36062953e-01 7.29090606e-01 1.06010316 0.68039059 731.75 3.84123188e-01 5.55780637e-01 6.75605461e-01 0.96604029 0.62115926 732.00 4.15096771e-01 4.81932612e-01 6.36053748e-01 0.85976872 0.56244316 732.25 3.20350868e-01 3.39239391e-01 4.66591945e-01 0.81402709 0.32637281 732.50 1.93859609e-01 2.81172225e-01 3.41525062e-01 0.96717299 0.17039731 732.75 1.32901213e-01 3.34249590e-01 3.59701989e-01 1.19235139 0.25241079 733.00 1.40989431e-01 3.42916374e-01 3.70769010e-01 1.18071658 0.31231093 733.25 5.10376933e-02 2.80175361e-01 2.84786023e-01 1.39060869 0.15041576 733.50 6.23554889e-02 2.69825582e-01 2.76936909e-01 1.34368769 0.13506122 733.75 -3.68878793e-03 4.80708898e-01 4.80723051e-01 1.57846982 0.30128655 734.00 3.58971002e-02 5.69363412e-01 5.70493906e-01 1.50783189 0.36353489 734.25 3.27722749e-01 5.08105342e-01 6.04626529e-01 0.99795130 0.35300000 734.50 4.25746498e-01 2.56475734e-01 4.97031068e-01 0.54219275 0.25901862 734.75 4.90407817e-01 -1.96578068e-01 5.28339629e-01 -0.38123557 0.25603916 735.00 3.69903189e-01 -3.14698967e-01 4.85658120e-01 -0.70493532 0.19232076 735.25 1.93551103e-01 -8.71291823e-01 8.92530935e-01 -1.35220318 0.41255185 735.50 -6.83096952e-02 -1.17340305e+00 1.17538970e+00 -1.62894573 0.46502825 735.75 -9.30531261e-01 -1.27619453e+00 1.57941790e+00 -2.20081629 0.61951660 736.00 -1.44057754e+00 -1.11753526e+00 1.82322481e+00 -2.48181105 0.66317737 736.25 -2.27169830e+00 -7.65025926e-01 2.39705608e+00 -2.81675779 0.70275251 736.50 -2.60498075e+00 -2.17838154e-01 2.61407310e+00 -3.05816305 0.76722682 736.75 -2.78481240e+00 4.55531547e-01 2.82182371e+00 2.97945154 0.85623819 737.00 -2.72965396e+00 1.03932305e+00 2.92082234e+00 2.77778810 0.84850762 737.25 -2.58468643e+00 1.66383636e+00 3.07391532e+00 2.56963885 0.83764242 737.50 -2.01539856e+00 2.06398162e+00 2.88476195e+00 2.34428563 0.79771903 737.75 -1.59865261e+00 2.58340682e+00 3.03803900e+00 2.12493611 0.87256176 738.00 -1.23421546e+00 2.62590396e+00 2.90149261e+00 2.01016988 0.82022151 738.25 -6.66144766e-01 2.68358115e+00 2.76502380e+00 1.81410821 0.87257801 738.50 -3.74312419e-01 2.58459230e+00 2.61155646e+00 1.71462091 0.86758599 738.75 -9.09496682e-02 2.40328229e+00 2.40500262e+00 1.60862221 0.88443750 739.00 1.59269431e-01 2.35304062e+00 2.35842467e+00 1.50321276 0.85633387 739.25 3.96514074e-01 2.21908850e+00 2.25423539e+00 1.39397905 0.90244170 739.50 5.38785601e-01 2.09385368e+00 2.16206225e+00 1.31894237 0.85449116 739.75 8.82028691e-01 2.17236567e+00 2.34459958e+00 1.18510920 0.89552796 740.00 1.00680992e+00 1.86344701e+00 2.11804178e+00 1.07543518 0.86954284 740.25 1.03823966e+00 1.51010954e+00 1.83258626e+00 0.96849129 0.84424901 740.50 1.11607069e+00 1.22102945e+00 1.65424506e+00 0.83027783 0.78029951 740.75 1.29998747e+00 1.06326557e+00 1.67943475e+00 0.68556336 0.77747550 741.00 1.21582475e+00 7.07313767e-01 1.40659965e+00 0.52689703 0.70651605 741.25 1.24841673e+00 4.33471016e-01 1.32152997e+00 0.33419303 0.66816195 741.50 1.15896465e+00 -4.61811490e-03 1.15897385e+00 -0.00398467 0.55357972 741.75 9.86969317e-01 -3.33783054e-01 1.04188270e+00 -0.32611508 0.60650746 742.00 6.68964960e-01 -5.83177636e-01 8.87474097e-01 -0.71699264 0.54934205 742.25 4.76733073e-01 -7.52292615e-01 8.90628206e-01 -1.00596031 0.57791789 742.50 -8.75453247e-02 -9.16235454e-01 9.20408382e-01 -1.66605607 0.53769372 742.75 -3.93045330e-01 -1.00586192e+00 1.07992723e+00 -1.94330735 0.57239756 743.00 -9.37709740e-01 -1.11492252e+00 1.45682936e+00 -2.27007363 0.52285847 743.25 -1.38975508e+00 -9.83215606e-01 1.70239012e+00 -2.52586817 0.60225536 743.50 -1.41656783e+00 -1.73559583e-01 1.42716059e+00 -3.01967907 0.56738910 743.75 -1.50988099e+00 6.88631126e-02 1.51145054e+00 3.09601593 0.55910523 744.00 -1.43492837e+00 5.82593787e-01 1.54868813e+00 2.75591689 0.44974048 744.25 -1.05526422e+00 7.96026280e-01 1.32183222e+00 2.49532077 0.39356039 744.50 -1.13836964e+00 1.44007187e+00 1.83567220e+00 2.23971462 0.67394967 744.75 -1.18217478e+00 1.46480196e+00 1.88233419e+00 2.24982392 0.72585403 745.00 -1.07387341e+00 1.64843253e+00 1.96736725e+00 2.14819107 0.75054482 745.25 -1.04516874e+00 1.77403419e+00 2.05902282e+00 2.10319822 0.77359075 745.50 -9.43474385e-01 1.82116441e+00 2.05104454e+00 2.04878817 0.79178488 745.75 -7.81625221e-01 1.87691557e+00 2.03316257e+00 1.96539543 0.85286658 746.00 -4.84023675e-01 1.98907411e+00 2.04711864e+00 1.80949813 0.87943300 746.25 -3.39094479e-01 1.93271857e+00 1.96224008e+00 1.74447809 0.85788594 746.50 -3.91080355e-01 1.81088335e+00 1.85263119e+00 1.78349094 0.85028115 746.75 -2.47357830e-01 1.67299378e+00 1.69118127e+00 1.71758626 0.80465381 747.00 -1.80460858e-01 1.48108951e+00 1.49204298e+00 1.69204200 0.80370051 747.25 -3.09966400e-01 1.50763182e+00 1.53916629e+00 1.77356894 0.82628500 747.50 -2.69611430e-01 1.53642619e+00 1.55990249e+00 1.74450729 0.85265974 747.75 -2.60174760e-01 1.47190827e+00 1.49472568e+00 1.74574935 0.75177913 748.00 -1.83758842e-01 1.31230591e+00 1.32510909e+00 1.70991918 0.64616588 748.25 -1.55851090e-01 1.25976988e+00 1.26937375e+00 1.69388484 0.60806593 748.50 7.14465364e-02 1.04894713e+00 1.05137752e+00 1.50278875 0.54976381 748.75 9.75692021e-02 7.19496483e-01 7.26081909e-01 1.43601091 0.30194353 749.00 9.21387933e-02 4.38040718e-01 4.47626214e-01 1.36347565 0.15172722 749.25 -1.50607512e-02 3.80288065e-01 3.80586178e-01 1.61037917 0.11685402 749.50 -7.76372096e-02 3.52315162e-01 3.60767944e-01 1.78769280 0.08999684 749.75 -4.68006075e-01 9.99449865e-02 4.78558969e-01 2.93119816 0.11569184 750.00 -7.00613521e-01 5.46901358e-03 7.00634866e-01 3.13378678 0.24756507 750.25 -1.19752399e+00 -2.44336836e-01 1.22219646e+00 -2.94032029 0.45927512 750.50 -1.65285412e+00 -5.91216110e-01 1.75540970e+00 -2.79807994 0.66985593 750.75 -2.05717550e+00 -5.91117942e-01 2.14041853e+00 -2.86178652 0.62480661 751.00 -2.96181264e+00 -4.89421172e-01 3.00197721e+00 -2.97782871 0.71256072 751.25 -3.71114244e+00 5.43719117e-01 3.75076108e+00 2.99611774 0.75792422 751.50 -4.12947027e+00 1.06320969e+00 4.26414581e+00 2.88959699 0.77217049 751.75 -3.83328603e+00 2.30104387e+00 4.47089305e+00 2.60096750 0.79474593 752.00 -3.82248714e+00 2.56015105e+00 4.60062836e+00 2.55145120 0.83602403 752.25 -3.27303841e+00 2.89092182e+00 4.36694509e+00 2.41810732 0.77447982 752.50 -2.76841951e+00 3.04222644e+00 4.11330625e+00 2.30910772 0.77959300 752.75 -2.97506461e+00 3.07280297e+00 4.27704659e+00 2.34003510 0.79183329 753.00 -2.74690220e+00 3.20828846e+00 4.22357509e+00 2.27887263 0.76941751 753.25 -1.47260260e+00 2.87710350e+00 3.23207100e+00 2.04386714 0.63647941 753.50 -1.60660133e+00 2.90310912e+00 3.31801302e+00 2.07625162 0.58653443 753.75 -2.02411991e+00 2.16338178e+00 2.96264783e+00 2.32295019 0.50364313 754.00 -2.01034881e+00 1.92737904e+00 2.78501208e+00 2.37726184 0.55704711 754.25 -1.90699713e+00 2.04630548e+00 2.79714215e+00 2.32097059 0.48642706 754.50 -2.13913157e+00 2.19349366e+00 3.06386983e+00 2.34364800 0.49311786 754.75 -2.45408078e+00 7.66708006e-01 2.57106080e+00 2.83877915 0.35984266 755.00 -2.30375854e+00 5.72485871e-01 2.37382465e+00 2.89802549 0.26886082 755.25 -3.27632314e+00 3.68560720e-01 3.29698806e+00 3.02957142 0.30261533 755.50 -4.21135436e+00 -1.78794247e-01 4.21514803e+00 -3.09916285 0.34574980 755.75 -3.83943032e+00 3.33557919e-01 3.85389233e+00 3.05493331 0.17279548 756.00 -4.90248418e+00 1.43438500e-01 4.90458211e+00 3.11234267 0.23386197 756.25 -5.26946413e+00 3.51343235e+00 6.33336081e+00 2.55353011 0.40954332 756.50 -4.79202238e+00 3.34546054e+00 5.84427795e+00 2.53212199 0.39826838 756.75 -4.49297445e+00 3.05360725e+00 5.43243376e+00 2.54466189 0.31722325 757.00 -4.19959681e+00 2.79459920e+00 5.04444229e+00 2.55443654 0.38129251 757.25 -4.36799925e+00 2.75170080e+00 5.16248726e+00 2.57942865 0.49848191 757.50 -4.91570538e+00 1.78708125e+00 5.23047023e+00 2.79290214 0.48783882 757.75 -5.29257696e+00 9.04714852e-02 5.29335017e+00 3.12450029 0.55241772 758.00 -5.03038066e+00 -8.31308997e-01 5.09860807e+00 -2.97781520 0.58273486 758.25 -4.38271982e+00 -2.24203122e+00 4.92289925e+00 -2.66873859 0.74987025 758.50 -3.93175378e+00 -2.89766812e+00 4.88417530e+00 -2.50646927 0.79050275 758.75 -3.46919445e+00 -3.83346574e+00 5.17018082e+00 -2.30635380 0.75905438 759.00 -2.95403052e+00 -3.89984469e+00 4.89234963e+00 -2.21906359 0.75727042 759.25 -2.63713399e+00 -3.72552970e+00 4.56443285e+00 -2.18677452 0.74401667 759.50 -2.47652320e+00 -3.60979574e+00 4.37764690e+00 -2.17210269 0.77293398 759.75 -2.34217606e+00 -3.80945741e+00 4.47188489e+00 -2.12205034 0.78403910 760.00 -1.77937145e+00 -3.56659180e+00 3.98581734e+00 -2.03356328 0.76711012 760.25 -1.60551169e+00 -3.27162077e+00 3.64433400e+00 -2.02700767 0.85053616 760.50 -1.52127744e+00 -3.08929071e+00 3.44354499e+00 -2.02837431 0.89673202 760.75 -1.08767337e+00 -2.92241405e+00 3.11825868e+00 -1.92709518 0.91861466 761.00 -7.92872358e-01 -2.81905158e+00 2.92842934e+00 -1.84496841 0.93208305 761.25 -7.65467911e-01 -2.60245968e+00 2.71269930e+00 -1.85686142 0.92603334 761.50 -7.41969673e-01 -2.27008305e+00 2.38826214e+00 -1.88669780 0.90444253 761.75 -7.20932721e-01 -2.07471221e+00 2.19640040e+00 -1.90522944 0.91911734 762.00 -5.56275016e-01 -1.79520354e+00 1.87941418e+00 -1.87128100 0.86934617 762.25 -3.63069062e-01 -1.48941619e+00 1.53302960e+00 -1.80989917 0.85194242 762.50 -1.37793472e-01 -1.32832727e+00 1.33545512e+00 -1.67416120 0.84363714 762.75 1.12480023e-01 -1.24170834e+00 1.24679243e+00 -1.48045798 0.85533887 763.00 3.99087799e-01 -1.13812691e+00 1.20606962e+00 -1.23353974 0.87166793 763.25 5.77474758e-01 -1.17865444e+00 1.31251796e+00 -1.11522577 0.89428024 763.50 8.10092586e-01 -1.27064417e+00 1.50691294e+00 -1.00322685 0.91656866 763.75 8.46140642e-01 -1.23011433e+00 1.49302888e+00 -0.96826777 0.92071111 764.00 9.68895395e-01 -1.27980492e+00 1.60519747e+00 -0.92278899 0.93108949 764.25 1.01026003e+00 -1.25721195e+00 1.61282584e+00 -0.89388127 0.94085450 764.50 1.03991107e+00 -1.19915243e+00 1.58725600e+00 -0.85639824 0.95144296 764.75 1.08195813e+00 -1.21476448e+00 1.62674095e+00 -0.84315813 0.95153369 765.00 1.21077794e+00 -1.25774594e+00 1.74582590e+00 -0.80442262 0.94312056 765.25 1.25321187e+00 -1.28887697e+00 1.79770516e+00 -0.79942708 0.94937508 765.50 1.20792410e+00 -1.36468976e+00 1.82248697e+00 -0.84625924 0.93177064 765.75 1.10032447e+00 -1.35475163e+00 1.74529823e+00 -0.88866264 0.91829355 766.00 9.84781131e-01 -1.23042198e+00 1.57598608e+00 -0.89583561 0.91696925 766.25 1.05757787e+00 -1.25429829e+00 1.64065083e+00 -0.87028493 0.91797447 766.50 1.14152169e+00 -1.17820742e+00 1.64050130e+00 -0.80121151 0.91907955 766.75 1.18839502e+00 -1.13640819e+00 1.64429507e+00 -0.76304007 0.93458062 767.00 1.25552959e+00 -1.16228821e+00 1.71092619e+00 -0.74685299 0.94082376 767.25 1.33535495e+00 -1.12234484e+00 1.74437117e+00 -0.69894369 0.91993806 767.50 1.39355371e+00 -1.15437537e+00 1.80957853e+00 -0.69180078 0.92330169 767.75 1.41569530e+00 -1.23469059e+00 1.87847120e+00 -0.71721032 0.92012749 768.00 1.52027342e+00 -1.55723818e+00 2.17628630e+00 -0.79740884 0.93369444 768.25 1.42643232e+00 -1.61601159e+00 2.15550519e+00 -0.84762921 0.93179006 768.50 1.42373029e+00 -1.79282939e+00 2.28937659e+00 -0.89964810 0.93964625 768.75 1.33652330e+00 -1.91130841e+00 2.33225092e+00 -0.96055953 0.93868520 769.00 1.12910181e+00 -1.98031279e+00 2.27958541e+00 -1.05260450 0.94203042 769.25 9.73528539e-01 -1.83785078e+00 2.07977242e+00 -1.08366392 0.93292868 769.50 8.13943845e-01 -1.70410174e+00 1.88850928e+00 -1.12519777 0.92323115 769.75 7.90014237e-01 -1.59820549e+00 1.78280209e+00 -1.11170841 0.87897501 770.00 6.20592107e-01 -1.59936276e+00 1.71554534e+00 -1.20065600 0.74502292 770.25 6.41151688e-01 -1.48805655e+00 1.62030484e+00 -1.16396836 0.65775944 770.50 9.41969224e-01 -1.28517355e+00 1.59341679e+00 -0.93829617 0.61012147 770.75 1.00191580e+00 -1.55291899e+00 1.84807810e+00 -0.99781537 0.51961495 771.00 9.58637561e-01 -1.87676939e+00 2.10742718e+00 -1.09855296 0.52985226 771.25 6.78905652e-01 -2.18705586e+00 2.29000572e+00 -1.26980762 0.54641526 771.50 3.22156067e-01 -2.78093305e+00 2.79953089e+00 -1.45546581 0.64837618 771.75 -9.52249713e-02 -2.61334610e+00 2.61508043e+00 -1.60721816 0.69236495 772.00 -2.89674923e-01 -2.64489499e+00 2.66071063e+00 -1.67988382 0.64738185 772.25 -5.93009840e-01 -2.68969256e+00 2.75428879e+00 -1.78779961 0.78002842 772.50 -6.57546037e-01 -2.66785707e+00 2.74769506e+00 -1.81244964 0.82456236 772.75 -8.68445735e-01 -2.33864335e+00 2.49468449e+00 -1.92635960 0.80624002 773.00 -1.19543120e+00 -2.19002808e+00 2.49505085e+00 -2.07044931 0.84562497 773.25 -1.19316536e+00 -1.76009874e+00 2.12640333e+00 -2.16653342 0.81003543 773.50 -1.13971834e+00 -1.54092371e+00 1.91661258e+00 -2.20762960 0.81915693 773.75 -1.04159017e+00 -1.37564823e+00 1.72549069e+00 -2.21886612 0.85005419 774.00 -9.02569430e-01 -1.31731026e+00 1.59685250e+00 -2.17149356 0.80971125 774.25 -6.23351290e-01 -1.20036113e+00 1.35256559e+00 -2.04976692 0.69824895 774.50 -5.15061738e-01 -1.12734778e+00 1.23943601e+00 -1.99935624 0.67759623 774.75 -5.15985416e-01 -1.22052884e+00 1.32511569e+00 -1.97076442 0.66605974 775.00 -5.18843527e-01 -1.34259698e+00 1.43936280e+00 -1.93956538 0.70379740 775.25 -4.95673806e-01 -1.51462892e+00 1.59367289e+00 -1.88706878 0.75413045 775.50 -5.43749619e-01 -1.61390331e+00 1.70304067e+00 -1.89576768 0.82728090 775.75 -5.68212860e-01 -1.61677283e+00 1.71371533e+00 -1.90876125 0.87358053 776.00 -5.82700512e-01 -1.52667728e+00 1.63410018e+00 -1.93540958 0.86303061 776.25 -6.58574698e-01 -1.49126548e+00 1.63021267e+00 -1.98666077 0.87843214 776.50 -7.52173668e-01 -1.57269135e+00 1.74330815e+00 -2.01691064 0.90321110 776.75 -1.05589913e+00 -1.55108838e+00 1.87637900e+00 -2.16848378 0.93101801 777.00 -1.20049348e+00 -1.45692320e+00 1.88780555e+00 -2.25999647 0.93947255 777.25 -1.32131558e+00 -1.33381779e+00 1.87748363e+00 -2.35148583 0.93649737 777.50 -1.32610205e+00 -1.08221283e+00 1.71164578e+00 -2.45712007 0.89257465 777.75 -1.33614740e+00 -7.76995924e-01 1.54564309e+00 -2.61487251 0.91975429 778.00 -1.26742291e+00 -7.20939002e-01 1.45811998e+00 -2.62441312 0.92786462 778.25 -1.12400386e+00 -5.51340931e-01 1.25194309e+00 -2.68556167 0.90291203 778.50 -1.03165663e+00 -5.19215501e-01 1.15494595e+00 -2.67532190 0.89642787 778.75 -9.67723953e-01 -5.81691578e-01 1.12909466e+00 -2.60037026 0.92020516 779.00 -9.78927884e-01 -6.23506758e-01 1.16062935e+00 -2.57446171 0.92785394 779.25 -9.43712691e-01 -6.22499686e-01 1.13053063e+00 -2.55847854 0.93059665 779.50 -1.00902143e+00 -5.69955452e-01 1.15886732e+00 -2.62741254 0.90011726 779.75 -1.11696151e+00 -3.69967462e-01 1.17663884e+00 -2.82173928 0.88873080 780.00 -1.10382671e+00 -1.97285118e-01 1.12131834e+00 -2.96473174 0.89270231 780.25 -8.96694250e-01 -1.49991516e-02 8.96819688e-01 -3.12486705 0.83928598 780.50 -7.93400196e-01 -2.01999274e-03 7.93402767e-01 -3.13904666 0.81411861 780.75 -5.95226356e-01 -1.33080517e-02 5.95375108e-01 -3.11923841 0.68819965 781.00 -4.53332353e-01 -2.28972976e-01 5.07876802e-01 -2.67388250 0.55698207 781.25 -4.27013590e-01 -5.16219090e-01 6.69942352e-01 -2.26190073 0.74141813 781.50 -5.58340402e-01 -6.27574009e-01 8.39995917e-01 -2.29788074 0.83932795 781.75 -7.36807278e-01 -7.08265146e-01 1.02201981e+00 -2.37594327 0.89399333 782.00 -8.95032402e-01 -7.13595881e-01 1.14468427e+00 -2.46850941 0.88554483 782.25 -1.03598757e+00 -5.73472634e-01 1.18412039e+00 -2.63602673 0.86241708 782.50 -1.18869133e+00 -4.10744743e-01 1.25765588e+00 -2.80889336 0.86438721 782.75 -1.28693953e+00 -2.67830640e-01 1.31451383e+00 -2.93640711 0.87455840 783.00 -1.24026301e+00 -2.81853653e-02 1.24058323e+00 -3.11887125 0.78575615 783.25 -1.20863267e+00 1.39073925e-01 1.21660778e+00 3.02702935 0.76513681 783.50 -9.56421331e-01 4.01355201e-01 1.03722117e+00 2.74426845 0.73316727 783.75 -8.95045163e-01 5.10488998e-01 1.03039064e+00 2.62326000 0.77600957 784.00 -7.26721544e-01 6.92021593e-01 1.00350291e+00 2.38064785 0.67650241 784.25 -5.15655006e-01 7.66659725e-01 9.23941134e-01 2.16289509 0.59673392 784.50 -2.36658987e-01 7.03981641e-01 7.42696188e-01 1.89509959 0.61231374 784.75 -1.25960717e-01 6.78294240e-01 6.89890700e-01 1.75440695 0.71192250 785.00 4.22068551e-03 6.30150166e-01 6.30164300e-01 1.56409852 0.73823526 785.25 4.02434999e-02 5.69351875e-01 5.70772368e-01 1.50023069 0.69819925 785.50 1.24815055e-01 4.48460997e-01 4.65506245e-01 1.29934743 0.67367817 785.75 1.91194555e-01 4.04882706e-01 4.47755920e-01 1.12961696 0.68713576 786.00 2.24958640e-01 1.88579773e-01 2.93545091e-01 0.69765430 0.43576900 786.25 1.76126637e-01 8.38163372e-02 1.95053250e-01 0.44417162 0.31407552 786.50 9.09305347e-02 1.60262985e-02 9.23320333e-02 0.17445604 0.17559817 786.75 5.10380982e-02 3.80112437e-03 5.11794492e-02 0.07433897 0.06395480 787.00 1.89689243e-02 2.74399254e-02 3.33582013e-02 0.96594049 0.03129447 787.25 7.72248340e-03 -4.90180398e-03 9.14682634e-03 -0.56557594 0.00340946 787.50 -1.08648422e-02 -2.00305791e-04 1.08666884e-02 -3.12315860 0.00878966 787.75 -2.19724554e-02 1.94515022e-02 2.93453528e-02 2.41697690 0.07806628 788.00 -4.36733771e-02 1.37970683e-02 4.58009057e-02 2.83559978 0.17541706 788.25 -5.14556684e-02 3.00695155e-02 5.95974964e-02 2.61273977 0.21633472 788.50 -3.77013272e-02 5.13522685e-02 6.37059303e-02 2.20408943 0.33839585 788.75 -3.98715617e-02 5.55302301e-02 6.83618891e-02 2.19351113 0.34226960 789.00 -1.27607631e-02 7.00115551e-02 7.11649838e-02 1.75108379 0.26730927 789.25 2.68573126e-03 7.34335472e-02 7.34826443e-02 1.53423899 0.33110970 789.50 2.42395037e-02 7.74445376e-02 8.11493065e-02 1.26746349 0.46456008 789.75 4.49524531e-02 6.76575664e-02 8.12297318e-02 0.98435674 0.40107658 790.00 9.18762609e-02 4.68403845e-02 1.03127440e-01 0.47147296 0.48085115 790.25 1.24513616e-01 1.71459809e-02 1.25688605e-01 0.13684304 0.51114276 790.50 1.30522674e-01 -7.02139112e-02 1.48209857e-01 -0.49354020 0.66958734 790.75 1.25244266e-01 -1.12612249e-01 1.68426972e-01 -0.73234029 0.67111567 791.00 1.01164891e-01 -1.82268013e-01 2.08460941e-01 -1.06409668 0.70493172 791.25 3.83551106e-02 -2.16181321e-01 2.19557460e-01 -1.39520255 0.70365725 791.50 4.09744797e-03 -2.46199017e-01 2.46233111e-01 -1.55415503 0.81787043 791.75 -2.36521979e-02 -2.68597199e-01 2.69636573e-01 -1.65862802 0.82571174 792.00 -7.82824268e-02 -2.92112350e-01 3.02419846e-01 -1.83263136 0.81061942 792.25 -1.39701947e-01 -3.05199129e-01 3.35653307e-01 -2.00006843 0.79772439 792.50 -1.87282987e-01 -3.25759494e-01 3.75758121e-01 -2.09256434 0.81347346 792.75 -2.83532122e-01 -3.94965570e-01 4.86197764e-01 -2.19341214 0.75044834 793.00 -4.22601916e-01 -4.47474325e-01 6.15488140e-01 -2.32761580 0.79231007 793.25 -6.29180500e-01 -2.98897364e-01 6.96568543e-01 -2.69809682 0.74565107 793.50 -7.98154950e-01 -1.53953453e-01 8.12867142e-01 -2.95104609 0.82796011 793.75 -9.12684112e-01 8.95035956e-03 9.12727997e-01 3.13178633 0.79690351 794.00 -9.63122876e-01 1.43053524e-01 9.73688854e-01 2.99413977 0.76124744 794.25 -8.47481350e-01 5.22882363e-01 9.95806510e-01 2.58877849 0.70807070 794.50 -7.30909510e-01 7.09533766e-01 1.01865935e+00 2.37103310 0.75359079 794.75 -5.66732004e-01 9.02306085e-01 1.06552402e+00 2.13161663 0.77363978 795.00 -5.57927553e-01 1.00920586e+00 1.15316071e+00 2.07581597 0.85172214 795.25 -2.81815400e-01 1.14538221e+00 1.17954242e+00 1.81204905 0.83695822 795.50 -1.81021731e-01 1.18237641e+00 1.19615335e+00 1.72271659 0.83773422 795.75 1.14105063e-01 1.25883671e+00 1.26399755e+00 1.48040010 0.77939873 796.00 2.20461604e-01 1.33751437e+00 1.35556188e+00 1.40743585 0.79653320 796.25 3.82908108e-01 1.36938862e+00 1.42191555e+00 1.29814026 0.82860419 796.50 5.56117570e-01 1.33579650e+00 1.44693436e+00 1.17630141 0.83943656 796.75 7.54177961e-01 1.16582091e+00 1.38849659e+00 0.99659837 0.84397617 797.00 9.32556812e-01 1.09798403e+00 1.44056625e+00 0.86668817 0.85335237 797.25 1.20568012e+00 9.40989521e-01 1.52942009e+00 0.66271451 0.85043962 797.50 1.29412574e+00 7.64652278e-01 1.50314821e+00 0.53367475 0.79125887 797.75 1.60212325e+00 3.92634785e-01 1.64953357e+00 0.24033474 0.82768640 798.00 1.61088821e+00 2.70205034e-01 1.63339266e+00 0.16618959 0.85006716 798.25 1.68031251e+00 1.41608342e-01 1.68626897e+00 0.08407633 0.85205406 798.50 1.66611075e+00 -3.28639200e-02 1.66643484e+00 -0.01972237 0.80128969 798.75 1.55136182e+00 -5.31367707e-01 1.63983997e+00 -0.32999291 0.74190279 799.00 1.41596005e+00 -7.29392365e-01 1.59278250e+00 -0.47567200 0.70815013 799.25 1.27033038e+00 -9.26049592e-01 1.57203916e+00 -0.62991416 0.77899087 799.50 1.14834763e+00 -1.06534976e+00 1.56642024e+00 -0.74792285 0.76949338 799.75 7.68983915e-01 -1.33180076e+00 1.53786525e+00 -1.04715904 0.79801595 800.00 5.25562877e-01 -1.42703991e+00 1.52074299e+00 -1.21792235 0.79843937 800.25 2.49998543e-01 -1.47938663e+00 1.50036132e+00 -1.40338994 0.82413139 800.50 1.40791549e-01 -1.42627304e+00 1.43320516e+00 -1.47240219 0.82702262 800.75 -7.25046746e-03 -1.39191397e+00 1.39193286e+00 -1.57600527 0.87967905 801.00 -2.24186152e-01 -1.42576767e+00 1.44328545e+00 -1.72675826 0.87821649 801.25 -4.37865896e-01 -1.43364403e+00 1.49902026e+00 -1.86721964 0.89286569 801.50 -5.97801393e-01 -1.35704756e+00 1.48288387e+00 -1.98573557 0.90599307 801.75 -7.92895363e-01 -1.23779434e+00 1.46997207e+00 -2.14051461 0.92366699 802.00 -9.32397899e-01 -1.05477746e+00 1.40780728e+00 -2.29468749 0.92258565 802.25 -1.01260516e+00 -8.69366472e-01 1.33460379e+00 -2.43215900 0.93514898 802.50 -1.07188366e+00 -6.58621759e-01 1.25806089e+00 -2.59061392 0.89827381 802.75 -1.17068938e+00 -4.85270539e-01 1.26728100e+00 -2.74863468 0.92343554 803.00 -1.15800302e+00 -1.34185388e-01 1.16575156e+00 -3.02623061 0.84109409 803.25 -1.02613909e+00 1.18403654e-01 1.03294766e+00 3.02671317 0.85411343 803.50 -7.64562823e-01 3.04336945e-01 8.22907823e-01 2.76276538 0.84366440 803.75 -6.00273706e-01 3.48753464e-01 6.94231590e-01 2.61526783 0.88901561 804.00 -4.40432113e-01 3.44316506e-01 5.59047675e-01 2.47806698 0.82857817 804.25 -3.34707365e-01 3.19066472e-01 4.62420191e-01 2.38011394 0.79450270 804.50 -1.07486287e-01 2.55930760e-01 2.77585763e-01 1.96840893 0.52761752 804.75 7.88091489e-05 2.24680946e-01 2.24680960e-01 1.57044557 0.59293124 805.00 6.21919997e-02 1.45811462e-01 1.58520747e-01 1.16763606 0.35935139 805.25 1.31710063e-01 5.72447629e-02 1.43612338e-01 0.40999655 0.32540857 805.50 2.60175805e-01 -3.80169258e-02 2.62938654e-01 -0.14509332 0.62856866 805.75 2.98769291e-01 -1.05878158e-01 3.16975194e-01 -0.34057236 0.73019415 806.00 3.33659637e-01 -2.76284771e-01 4.33199755e-01 -0.69160841 0.69216039 806.25 3.74057386e-01 -4.16803653e-01 5.60039475e-01 -0.83939591 0.76742837 806.50 3.14575358e-01 -6.42296362e-01 7.15193870e-01 -1.11536884 0.81168776 806.75 2.21936496e-01 -7.79301637e-01 8.10288127e-01 -1.29335237 0.79879676 807.00 6.81550401e-02 -1.00301199e+00 1.00532490e+00 -1.50295025 0.87597155 807.25 8.06053746e-03 -1.08578018e+00 1.08581010e+00 -1.56337273 0.88335349 807.50 -2.79136706e-01 -1.28158888e+00 1.31163538e+00 -1.78525218 0.89136226 807.75 -5.10279739e-01 -1.35393861e+00 1.44690537e+00 -1.93121895 0.90619275 808.00 -8.07483231e-01 -1.35471566e+00 1.57711245e+00 -2.10830906 0.89898912 808.25 -1.05029373e+00 -1.33288963e+00 1.69697133e+00 -2.23816646 0.90392407 808.50 -1.39868162e+00 -1.12162570e+00 1.79286210e+00 -2.46568428 0.92033698 808.75 -1.54221898e+00 -9.67208443e-01 1.82042071e+00 -2.58144606 0.93050302 809.00 -1.61055080e+00 -6.94860662e-01 1.75405394e+00 -2.73427752 0.92968938 809.25 -1.58900409e+00 -5.29010907e-01 1.67474969e+00 -2.82021433 0.91091452 809.50 -1.59591960e+00 -2.81182403e-01 1.62050082e+00 -2.96719421 0.90052424 809.75 -1.47212514e+00 -1.16805426e-01 1.47675182e+00 -3.06241377 0.85858281 810.00 -1.41830014e+00 -4.74199143e-03 1.41830806e+00 -3.13824923 0.81216028 810.25 -1.20191171e+00 -5.77443213e-03 1.20192558e+00 -3.13678832 0.74562046 810.50 -1.02077479e+00 4.72748214e-02 1.02186891e+00 3.09531304 0.75870622 810.75 -1.07175942e+00 5.61387875e-02 1.07322869e+00 3.08926045 0.74234395 811.00 -1.13863726e+00 -1.20074318e-03 1.13863789e+00 -3.14053811 0.75374132 811.25 -1.18753150e+00 1.07009848e-01 1.19234314e+00 3.05172421 0.69469312 811.50 -1.22741682e+00 1.01196220e-01 1.23158139e+00 3.05933220 0.64725112 811.75 -9.58091282e-01 7.88859208e-02 9.61333393e-01 3.05944142 0.52182870 812.00 -8.54974424e-01 1.32334151e-01 8.65155242e-01 2.98802982 0.60609148 812.25 -8.70019056e-01 1.57235090e-01 8.84113133e-01 2.96279656 0.59977059 812.50 -9.48669233e-01 1.78157894e-01 9.65253101e-01 2.95595714 0.64222408 812.75 -9.59134693e-01 1.45910683e-01 9.70169720e-01 2.99062276 0.58480767 813.00 -1.05129818e+00 1.96693281e-01 1.06954014e+00 2.95663538 0.69697141 813.25 -9.59965985e-01 2.12552233e-01 9.83215716e-01 2.92369172 0.59518079 813.50 -9.09158794e-01 1.71039171e-01 9.25107621e-01 2.95563710 0.62645729 813.75 -9.83605207e-01 2.45602293e-01 1.01380456e+00 2.89690012 0.54531358 814.00 -1.12004699e+00 3.75876229e-01 1.18143481e+00 2.81781275 0.58787582 814.25 -1.18747883e+00 5.52313623e-01 1.30963976e+00 2.70624084 0.60224709 814.50 -1.05164523e+00 7.54492011e-01 1.29430131e+00 2.51925785 0.65962394 814.75 -1.12891688e+00 8.29447717e-01 1.40087003e+00 2.50793698 0.69872769 815.00 -1.16700559e+00 8.09777011e-01 1.42043685e+00 2.53497711 0.68992402 815.25 -1.02618855e+00 8.04420976e-01 1.30390032e+00 2.47675114 0.59246129 815.50 -8.86119638e-01 7.97451178e-01 1.19211425e+00 2.40881278 0.55104725 815.75 -4.97893809e-01 6.98614152e-01 8.57881098e-01 2.18998696 0.34830478 816.00 -4.79332999e-01 7.95234638e-01 9.28524773e-01 2.11324034 0.39264069 816.25 -2.29103487e-01 8.33612625e-01 8.64522074e-01 1.83900641 0.33732494 816.50 7.70010067e-03 7.22209747e-01 7.22250794e-01 1.56013487 0.24592400 816.75 4.27017028e-01 3.64385153e-01 5.61355575e-01 0.70642238 0.14496723 817.00 5.54007231e-01 1.77341610e-01 5.81699285e-01 0.30980003 0.12224278 817.25 5.55812152e-01 -7.63919722e-01 9.44722441e-01 -0.94179958 0.20461279 817.50 2.44544064e-01 -1.07440995e+00 1.10188863e+00 -1.34700115 0.26172699 817.75 -3.12258840e-01 -1.85774244e+00 1.88380269e+00 -1.73732479 0.48158625 818.00 -7.08769304e-01 -1.94723251e+00 2.07221340e+00 -1.91987788 0.50074834 818.25 -1.33033960e+00 -1.73356481e+00 2.18518887e+00 -2.22534146 0.54264676 818.50 -1.33026271e+00 -1.68520656e+00 2.14697928e+00 -2.23902597 0.51509532 818.75 -1.72781912e+00 -1.74095784e+00 2.45281331e+00 -2.35240680 0.56303146 819.00 -2.12793603e+00 -1.91167668e+00 2.86052783e+00 -2.40967811 0.59323299 819.25 -3.15401351e+00 -2.33148569e+00 3.92219667e+00 -2.50503147 0.72416520 819.50 -3.49188586e+00 -2.64966302e+00 4.38337553e+00 -2.49247965 0.71335143 819.75 -4.89329578e+00 -3.17437097e+00 5.83275018e+00 -2.56611892 0.75890623 820.00 -5.72890536e+00 -2.34694869e+00 6.19100354e+00 -2.75277975 0.73883500 820.25 -6.59040949e+00 -1.40246924e+00 6.73798317e+00 -2.93191587 0.74818670 820.50 -6.49539622e+00 -1.38735754e-01 6.49687769e+00 -3.12023681 0.73804242 820.75 -6.86927603e+00 7.55078695e-01 6.91065098e+00 3.03211104 0.81297385 821.00 -7.15885703e+00 1.30044791e+00 7.27601531e+00 2.96189634 0.81218833 821.25 -7.32657858e+00 2.08196766e+00 7.61664907e+00 2.86472462 0.84043938 821.50 -7.70105017e+00 2.60203526e+00 8.12876136e+00 2.81575518 0.82611727 821.75 -8.19416063e+00 3.46840083e+00 8.89798139e+00 2.74118219 0.80247932 822.00 -8.07649040e+00 4.87244592e+00 9.43241360e+00 2.59875936 0.79880555 822.25 -8.11153787e+00 6.46303723e+00 1.03714944e+01 2.46882379 0.79759540 822.50 -7.41650354e+00 8.60973689e+00 1.13636303e+01 2.28187664 0.84193176 822.75 -6.53086423e+00 9.80454473e+00 1.17805469e+01 2.15841055 0.89089456 823.00 -4.22557901e+00 9.81769795e+00 1.06884382e+01 1.97723551 0.90301033 823.25 -2.78759022e+00 9.22226468e+00 9.63435650e+00 1.86433203 0.92911634 823.50 -3.09715366e+00 8.28336316e+00 8.84344197e+00 1.92860271 0.94307995 823.75 -3.53503352e+00 8.25469701e+00 8.97978200e+00 1.97541239 0.94938449 824.00 -3.35795493e+00 9.71023552e+00 1.02744603e+01 1.90373891 0.93070506 824.25 -2.92174373e+00 1.10522839e+01 1.14319538e+01 1.82924074 0.94345922 824.50 -1.21188219e+00 1.17493098e+01 1.18116442e+01 1.67357783 0.92416955 824.75 3.51041967e-01 1.25008983e+01 1.25058262e+01 1.54272237 0.94802114 825.00 1.50226323e+00 1.22350283e+01 1.23269101e+01 1.44862403 0.92904094 825.25 2.98646458e+00 1.21777532e+01 1.25386061e+01 1.33030325 0.90721271 825.50 5.65254025e+00 1.02610209e+01 1.17149375e+01 1.06728155 0.90342604 825.75 6.48209464e+00 9.80513376e+00 1.17540716e+01 0.98666310 0.92685989 826.00 7.71564057e+00 8.31263767e+00 1.13415631e+01 0.82262744 0.87139121 826.25 8.30392589e+00 6.93721689e+00 1.08203587e+01 0.69596502 0.89593131 826.50 7.36658823e+00 5.75628386e+00 9.34887298e+00 0.66329881 0.87666100 826.75 6.78968244e+00 5.00419145e+00 8.43455510e+00 0.63514772 0.87302838 827.00 5.87415816e+00 4.44085515e+00 7.36389358e+00 0.64732915 0.88480481 827.25 5.64638447e+00 4.19574021e+00 7.03462106e+00 0.63906041 0.90454305 827.50 5.72564545e+00 3.38786426e+00 6.65286706e+00 0.53429419 0.91218496 827.75 5.78256524e+00 3.10181561e+00 6.56196013e+00 0.49234822 0.91507013 828.00 6.09067528e+00 3.42526680e+00 6.98775916e+00 0.51229741 0.93920078 828.25 5.90361322e+00 3.48923108e+00 6.85765139e+00 0.53380013 0.93896278 828.50 6.04851499e+00 3.29685163e+00 6.88866927e+00 0.49904872 0.95369876 828.75 6.39358855e+00 2.74023442e+00 6.95606636e+00 0.40490831 0.95616527 829.00 6.33490508e+00 2.36278666e+00 6.76119688e+00 0.35699767 0.96078351 829.25 6.16398641e+00 2.14648331e+00 6.52702988e+00 0.33509687 0.96481794 829.50 5.98370712e+00 1.39751353e+00 6.14473717e+00 0.22944037 0.96151732 829.75 5.75116661e+00 8.34602425e-01 5.81140935e+00 0.14411278 0.96084383 830.00 5.48858183e+00 4.08475776e-01 5.50376080e+00 0.07428588 0.95673775 830.25 5.22630580e+00 3.67401235e-01 5.23920375e+00 0.07018300 0.94828332 830.50 4.78928769e+00 4.15088761e-01 4.80724196e+00 0.08645421 0.95130848 830.75 4.54026294e+00 6.77724404e-01 4.59056619e+00 0.14817580 0.93255303 831.00 4.35121904e+00 6.10188681e-01 4.39379532e+00 0.13932540 0.91340818 831.25 4.06924283e+00 6.02113477e-01 4.11354808e+00 0.14690105 0.91199979 831.50 3.94996942e+00 5.24150380e-01 3.98459434e+00 0.13192658 0.93289736 831.75 3.75794346e+00 4.40832710e-01 3.78371147e+00 0.11677322 0.91467818 832.00 3.41546222e+00 3.48902796e-01 3.43323686e+00 0.10180077 0.88361758 832.25 3.53475100e+00 4.04299982e-01 3.55779751e+00 0.11388373 0.86982479 832.50 3.48776796e+00 5.95828722e-01 3.53829581e+00 0.16920044 0.85032020 832.75 3.14813334e+00 8.06809831e-01 3.24987471e+00 0.25088232 0.79471355 833.00 2.59558774e+00 8.47397192e-01 2.73041347e+00 0.31556634 0.71760157 833.25 2.46156055e+00 1.01207717e+00 2.66149968e+00 0.39008361 0.58407077 833.50 2.49555309e+00 1.16472684e+00 2.75397419e+00 0.43667171 0.50899075 833.75 2.83099561e+00 1.67562778e+00 3.28972105e+00 0.53443225 0.56231594 834.00 2.81672270e+00 2.04876966e+00 3.48301362e+00 0.62885296 0.54267375 834.25 2.64028992e+00 1.92462602e+00 3.26731023e+00 0.62988914 0.40451412 834.50 3.09284037e+00 1.72642872e+00 3.54206404e+00 0.50911828 0.43302524 834.75 2.51654406e+00 7.34734700e-01 2.62160811e+00 0.28406607 0.21942773 835.00 1.89149692e+00 3.38241764e-01 1.92150152e+00 0.17695193 0.09453986 835.25 2.03632151e+00 -3.24668953e-01 2.06204152e+00 -0.15810816 0.13518701 835.50 2.05167535e+00 -5.41083256e-01 2.12182536e+00 -0.25785637 0.14172552 835.75 1.24414607e+00 -1.28842754e+00 1.79107369e+00 -0.80288115 0.12725374 836.00 1.30363823e+00 -1.46280469e+00 1.95940557e+00 -0.84286951 0.17343617 836.25 1.00661927e+00 -1.92124046e+00 2.16897378e+00 -1.08817880 0.23354455 836.50 8.14938859e-01 -1.94937476e+00 2.11286235e+00 -1.17482589 0.25051844 836.75 7.08616446e-01 -1.60458355e+00 1.75408826e+00 -1.15493289 0.14653914 837.00 8.98509555e-01 -1.61951372e+00 1.85206482e+00 -1.06427379 0.16875249 837.25 3.49730181e-01 -1.57510964e+00 1.61346881e+00 -1.35230537 0.23113709 837.50 3.42775954e-01 -1.39054706e+00 1.43217195e+00 -1.32911035 0.21848133 837.75 2.31442091e-01 -5.89260111e-01 6.33082080e-01 -1.19654056 0.06495897 838.00 3.35552112e-01 -4.20420326e-01 5.37911211e-01 -0.89719371 0.07792290 838.25 7.29238780e-01 -2.87275889e-01 7.83783538e-01 -0.37527083 0.12306503 838.50 8.14048256e-01 2.60860955e-02 8.14466111e-01 0.03203394 0.13613376 838.75 1.03973492e+00 2.70487548e-01 1.07434269e+00 0.25450901 0.20980994 839.00 1.51080348e+00 -3.29464600e-01 1.54630982e+00 -0.21471099 0.30690806 839.25 1.90877768e+00 -1.59560002e+00 2.48784479e+00 -0.69626739 0.54002767 839.50 1.61114446e+00 -2.18589687e+00 2.71549840e+00 -0.93562622 0.59124117 839.75 9.65278607e-01 -2.73541449e+00 2.90073357e+00 -1.23155631 0.60883792 840.00 5.79987494e-01 -2.66090488e+00 2.72338030e+00 -1.35618670 0.59783070 840.25 3.85431276e-01 -2.92150907e+00 2.94682414e+00 -1.43962502 0.66253096 840.50 -1.59227209e-01 -2.44009401e+00 2.44528364e+00 -1.63595848 0.51279249 840.75 -3.95769222e-01 -2.36587316e+00 2.39874740e+00 -1.73654415 0.47469658 841.00 -6.59324634e-01 -2.61067397e+00 2.69264323e+00 -1.81817316 0.56917186 841.25 -7.50904473e-01 -2.67165139e+00 2.77517183e+00 -1.84479121 0.62433992 841.50 -9.07508431e-01 -2.65124949e+00 2.80226612e+00 -1.90059024 0.63766718 841.75 -8.94220374e-01 -3.23649093e+00 3.35775277e+00 -1.84036440 0.70759245 842.00 -8.54154527e-01 -3.44510713e+00 3.54941447e+00 -1.81382830 0.74448803 842.25 -8.81032141e-01 -3.43366738e+00 3.54489624e+00 -1.82196423 0.74322877 842.50 -1.09806628e+00 -3.31331743e+00 3.49053319e+00 -1.89081482 0.74912342 842.75 -8.42177831e-01 -3.36947712e+00 3.47313109e+00 -1.81572151 0.77773259 843.00 -8.67351809e-01 -3.26555813e+00 3.37878219e+00 -1.83040820 0.67377548 843.25 -9.71229837e-01 -3.33411503e+00 3.47269498e+00 -1.85425307 0.69533701 843.50 -1.37670079e+00 -4.03594015e+00 4.26428399e+00 -1.89952975 0.83438002 843.75 -1.53695394e+00 -4.51509619e+00 4.76952000e+00 -1.89889636 0.82445684 844.00 -1.62659956e+00 -4.49499488e+00 4.78025157e+00 -1.91800554 0.78910184 844.25 -2.35866392e+00 -4.90636931e+00 5.44387319e+00 -2.01891357 0.77919054 844.50 -2.73446223e+00 -5.19863949e+00 5.87393703e+00 -2.05502360 0.76150154 844.75 -3.44913296e+00 -5.42021328e+00 6.42458015e+00 -2.13751324 0.75143546 845.00 -5.02001625e+00 -5.05017225e+00 7.12073050e+00 -2.35319992 0.71609830 845.25 -6.27265410e+00 -4.53002847e+00 7.73739926e+00 -2.51613084 0.70954980 845.50 -7.62641817e+00 -2.77276652e+00 8.11483138e+00 -2.79287683 0.67199633 845.75 -9.25704632e+00 -1.59711048e+00 9.39381011e+00 -2.97074540 0.71344794 846.00 -8.33364206e+00 2.63424686e+00 8.74007131e+00 2.83543334 0.58390934 846.25 -6.70069665e+00 4.79215699e+00 8.23796724e+00 2.52075592 0.62810984 846.50 -4.57440821e+00 3.69264875e+00 5.87884898e+00 2.46245218 0.75780341 846.75 -4.10414850e+00 3.70184722e+00 5.52699808e+00 2.40768640 0.82233927 847.00 -3.60369103e+00 3.31058851e+00 4.89352484e+00 2.39856002 0.76968551 847.25 -3.54504304e+00 2.66447390e+00 4.43472111e+00 2.49706481 0.70443932 847.50 -3.12029023e+00 2.31953102e+00 3.88798602e+00 2.50234809 0.66835884 847.75 -2.76749356e+00 1.77527848e+00 3.28795290e+00 2.57123363 0.59513735 848.00 -2.94363832e+00 1.71689266e+00 3.40774515e+00 2.61357643 0.57444247 848.25 -2.88659861e+00 1.51301618e+00 3.25909029e+00 2.65881073 0.60882230 848.50 -2.62882763e+00 1.84369784e+00 3.21091209e+00 2.52996898 0.62827386 848.75 -2.27080642e+00 1.78873495e+00 2.89069793e+00 2.47439121 0.60946935 849.00 -1.81329260e+00 1.31805078e+00 2.24171540e+00 2.51305160 0.49459437 849.25 -1.86290319e+00 1.35658500e+00 2.30450237e+00 2.51218352 0.54090016 849.50 -1.70522287e+00 9.05245152e-01 1.93060970e+00 2.65355809 0.52395607 849.75 -1.47780423e+00 6.38875938e-01 1.60999000e+00 2.73354305 0.43338992 850.00 -1.71510765e+00 7.51201133e-02 1.71675196e+00 3.09782156 0.46622373 850.25 -1.46073932e+00 -1.40202933e-01 1.46745229e+00 -3.04590497 0.48525968 850.50 -1.64017080e+00 -8.47066164e-01 1.84599061e+00 -2.66487184 0.54499462 850.75 -1.96476530e+00 -9.60388641e-01 2.18692684e+00 -2.68694045 0.63653732 851.00 -2.00543672e+00 -1.20744009e+00 2.34087335e+00 -2.59964268 0.71697821 851.25 -2.06972563e+00 -1.49516914e+00 2.55329100e+00 -2.51599100 0.72646582 851.50 -1.89465047e+00 -1.51426749e+00 2.42542912e+00 -2.46731947 0.61857073 851.75 -1.65376829e+00 -1.66651055e+00 2.34780897e+00 -2.35235680 0.57087503 852.00 -1.84379708e+00 -2.12966829e+00 2.81692646e+00 -2.28437318 0.67118087 852.25 -1.50216949e+00 -2.45838168e+00 2.88099872e+00 -2.11929394 0.71382710 852.50 -1.01060467e+00 -2.90270435e+00 3.07359957e+00 -1.90583074 0.66909269 852.75 -1.35800989e+00 -3.33848411e+00 3.60411807e+00 -1.95712903 0.72728974 853.00 -1.42995785e+00 -3.87107490e+00 4.12674210e+00 -1.92464448 0.80726863 853.25 -7.50437494e-01 -3.95885702e+00 4.02935545e+00 -1.75813273 0.78364789 853.50 6.87718888e-02 -4.04131946e+00 4.04190457e+00 -1.55378078 0.80751575 853.75 4.76279381e-01 -4.27929058e+00 4.30571363e+00 -1.45995383 0.84534503 854.00 9.23728093e-01 -4.70106629e+00 4.79096001e+00 -1.37677484 0.87276074 854.25 1.40684514e+00 -5.40579674e+00 5.58586177e+00 -1.31619644 0.84175509 854.50 1.65867401e+00 -6.19597805e+00 6.41415181e+00 -1.30922784 0.82045915 854.75 9.41665289e-01 -6.56872401e+00 6.63587738e+00 -1.42841053 0.75864927 855.00 5.73064562e-02 -7.11203396e+00 7.11226483e+00 -1.56273883 0.63772357 855.25 3.17923891e-01 -7.15614659e+00 7.16320526e+00 -1.52639883 0.58889222 855.50 -3.07579895e-02 -5.70191829e+00 5.70200125e+00 -1.57619060 0.42033987 855.75 -3.64527390e-01 -5.90367236e+00 5.91491568e+00 -1.63246391 0.62435178 856.00 -1.26454094e+00 -6.51736326e+00 6.63890711e+00 -1.76244156 0.67828747 856.25 -1.90657423e+00 -5.91385251e+00 6.21358807e+00 -1.88266688 0.64362201 856.50 -2.12516038e+00 -5.91671660e+00 6.28679903e+00 -1.91562492 0.63122640 856.75 -2.07063388e+00 -5.26526133e+00 5.65778238e+00 -1.94548172 0.63919684 857.00 -1.66784813e+00 -4.62879728e+00 4.92010993e+00 -1.91663515 0.56959509 857.25 -1.84932919e+00 -4.39271403e+00 4.76612579e+00 -1.96927341 0.44923254 857.50 -1.93221712e+00 -4.44246782e+00 4.84447968e+00 -1.98105795 0.55176236 857.75 -3.52343620e+00 -4.27004582e+00 5.53605401e+00 -2.26068672 0.66674246 858.00 -4.02567490e+00 -4.41689956e+00 5.97620784e+00 -2.30988812 0.67915471 858.25 -3.69409497e+00 -3.21012231e+00 4.89399867e+00 -2.42617813 0.65976172 858.50 -3.72995138e+00 -2.55476241e+00 4.52098974e+00 -2.54105131 0.65945297 858.75 -3.14916945e+00 -1.92695693e+00 3.69194139e+00 -2.59247366 0.59308629 859.00 -3.05913076e+00 -1.89689871e+00 3.59951465e+00 -2.58654081 0.61219764 859.25 -2.39503137e+00 -1.94375540e+00 3.08453567e+00 -2.45983156 0.58540104 859.50 -2.18004167e+00 -2.06684842e+00 3.00407125e+00 -2.38284139 0.58975037 859.75 -2.53854552e+00 -2.36130790e+00 3.46698549e+00 -2.39235075 0.72085570 860.00 -2.35795090e+00 -2.56693620e+00 3.48555504e+00 -2.31378540 0.72605834 860.25 -2.31614333e+00 -2.39554664e+00 3.33214099e+00 -2.33934368 0.77343080 860.50 -2.42047431e+00 -1.80855745e+00 3.02151882e+00 -2.49989151 0.76047717 860.75 -2.46977786e+00 -1.59722178e+00 2.94124465e+00 -2.56753610 0.78019557 861.00 -2.35629122e+00 -1.52905067e+00 2.80893294e+00 -2.56597519 0.80132490 861.25 -1.85733130e+00 -9.68072649e-01 2.09447946e+00 -2.66111587 0.79689213 861.50 -1.59726355e+00 -1.04510223e+00 1.90879268e+00 -2.56219496 0.82851721 861.75 -1.29241770e+00 -1.23112046e+00 1.78493728e+00 -2.38047991 0.84825642 862.00 -1.12784691e+00 -1.41582938e+00 1.81014129e+00 -2.24345946 0.82402026 862.25 -8.90236108e-01 -1.59662667e+00 1.82804186e+00 -2.07943523 0.87177203 862.50 -7.53823213e-01 -1.69216161e+00 1.85247412e+00 -1.98988460 0.85202813 862.75 -6.48306880e-01 -1.95257695e+00 2.05739120e+00 -1.89137008 0.89310442 863.00 -7.76790548e-01 -2.02938005e+00 2.17296731e+00 -1.93636363 0.89238387 863.25 -1.09978693e+00 -2.26057093e+00 2.51390378e+00 -2.02359259 0.88132155 863.50 -1.23892304e+00 -2.22665616e+00 2.54812243e+00 -2.07854385 0.87990313 863.75 -1.31765649e+00 -2.08780839e+00 2.46883829e+00 -2.13378405 0.90150503 864.00 -1.28879865e+00 -2.01743706e+00 2.39396204e+00 -2.13927882 0.92059925 864.25 -1.29284077e+00 -1.97910722e+00 2.36395910e+00 -2.14944896 0.93052245 864.50 -1.31966273e+00 -1.93076469e+00 2.33866672e+00 -2.17035715 0.90431519 864.75 -1.33257170e+00 -1.92933308e+00 2.34479711e+00 -2.17524682 0.90981318 865.00 -1.45198401e+00 -1.91152482e+00 2.40045510e+00 -2.22040978 0.91738228 865.25 -1.64374731e+00 -1.69778568e+00 2.36312958e+00 -2.34002417 0.93237464 865.50 -1.64471664e+00 -1.60277251e+00 2.29651313e+00 -2.36910964 0.94929548 865.75 -1.65291224e+00 -1.53373467e+00 2.25487492e+00 -2.39357612 0.96928862 866.00 -1.62804980e+00 -1.44958503e+00 2.17987222e+00 -2.41411726 0.96315299 866.25 -1.63919453e+00 -1.32324730e+00 2.10664238e+00 -2.46244381 0.96627991 866.50 -1.55859397e+00 -1.17395959e+00 1.95125506e+00 -2.49603579 0.96411008 866.75 -1.53909270e+00 -1.04721403e+00 1.86157556e+00 -2.54413570 0.97220779 867.00 -1.43736174e+00 -9.65713879e-01 1.73165010e+00 -2.54999943 0.96194769 867.25 -1.39074995e+00 -9.42334843e-01 1.67993464e+00 -2.54607736 0.96508355 867.50 -1.27956764e+00 -9.02110502e-01 1.56559787e+00 -2.52751087 0.95476901 867.75 -1.20632115e+00 -8.82215424e-01 1.49449482e+00 -2.51014966 0.95637889 868.00 -1.15323616e+00 -8.23839805e-01 1.41727403e+00 -2.52128593 0.95291905 868.25 -1.13654919e+00 -8.02879550e-01 1.39153140e+00 -2.52657185 0.96326776 868.50 -1.03872825e+00 -7.61222127e-01 1.28779482e+00 -2.50916438 0.96445502 868.75 -1.02565114e+00 -7.42220556e-01 1.26603776e+00 -2.51516472 0.95123166 869.00 -1.00842817e+00 -7.13372462e-01 1.23524396e+00 -2.52591064 0.90352205 869.25 -9.54958554e-01 -7.30423251e-01 1.20227450e+00 -2.48863976 0.92710199 869.50 -9.46849679e-01 -7.38835481e-01 1.20100049e+00 -2.47897417 0.92711940 869.75 -9.52754058e-01 -7.30533675e-01 1.20059141e+00 -2.48745117 0.92554353 870.00 -9.08806380e-01 -7.59262476e-01 1.18423331e+00 -2.44560638 0.89469130 870.25 -8.60397174e-01 -7.74795604e-01 1.15783916e+00 -2.40849628 0.86530919 870.50 -7.77785473e-01 -8.76817596e-01 1.17207480e+00 -2.29641331 0.90354792 870.75 -8.52201409e-01 -9.15309195e-01 1.25061511e+00 -2.32050532 0.93047307 871.00 -9.07407006e-01 -8.48595680e-01 1.24237760e+00 -2.38967357 0.92195466 871.25 -8.97206595e-01 -8.11448593e-01 1.20972249e+00 -2.40634276 0.92433054 871.50 -8.35927310e-01 -8.80088268e-01 1.21380799e+00 -2.33046558 0.89643233 871.75 -8.78806710e-01 -8.91476728e-01 1.25181148e+00 -2.34903756 0.90395141 872.00 -9.00331050e-01 -9.19574198e-01 1.28693928e+00 -2.34562118 0.93869291 872.25 -9.09398888e-01 -9.61470008e-01 1.32341638e+00 -2.32836909 0.92899791 872.50 -9.91642920e-01 -1.04795867e+00 1.44276577e+00 -2.32859035 0.92523121 872.75 -1.13968455e+00 -1.01584566e+00 1.52670340e+00 -2.41358311 0.89695074 873.00 -1.19881346e+00 -9.08609939e-01 1.50423593e+00 -2.49303921 0.89594900 873.25 -1.17692196e+00 -8.31233752e-01 1.44086601e+00 -2.52666587 0.89655792 873.50 -1.14133603e+00 -6.88251569e-01 1.33279337e+00 -2.59895352 0.90313598 873.75 -1.06307089e+00 -6.68613661e-01 1.25585188e+00 -2.58016115 0.86503200 874.00 -1.06809303e+00 -7.36920197e-01 1.29764174e+00 -2.53765026 0.89011120 874.25 -1.07355734e+00 -7.79198134e-01 1.32652745e+00 -2.51375405 0.91354836 874.50 -1.03775351e+00 -7.93239924e-01 1.30620133e+00 -2.48895054 0.93315289 874.75 -1.05480090e+00 -7.75786480e-01 1.30936993e+00 -2.50744836 0.91338418 875.00 -1.09140184e+00 -7.82488117e-01 1.34292428e+00 -2.51957662 0.91480591 875.25 -1.04811310e+00 -8.19278575e-01 1.33032269e+00 -2.47812890 0.91488028 875.50 -1.05237787e+00 -8.80907940e-01 1.37240591e+00 -2.44465653 0.93315943 875.75 -1.05598759e+00 -9.92940660e-01 1.44949679e+00 -2.38695547 0.91224083 876.00 -1.07030399e+00 -1.15462731e+00 1.57439349e+00 -2.31831333 0.92419946 876.25 -1.10400142e+00 -1.23369149e+00 1.65554035e+00 -2.30077350 0.88872731 876.50 -1.26667465e+00 -1.32487543e+00 1.83296469e+00 -2.33374036 0.91618951 876.75 -1.36999048e+00 -1.28275533e+00 1.87678852e+00 -2.38906749 0.89338896 877.00 -1.50213731e+00 -1.22330285e+00 1.93723679e+00 -2.45814781 0.87681568 877.25 -1.75117684e+00 -1.50413600e+00 2.30847253e+00 -2.43193782 0.89813838 877.50 -1.86281569e+00 -1.57785835e+00 2.44125363e+00 -2.43882611 0.92081226 877.75 -2.11806943e+00 -1.47314810e+00 2.57999678e+00 -2.53388341 0.91533948 878.00 -2.37792686e+00 -1.43360209e+00 2.77664385e+00 -2.59905895 0.92428578 878.25 -2.49530862e+00 -1.38072135e+00 2.85183389e+00 -2.63619880 0.91040906 878.50 -2.68207883e+00 -1.25093360e+00 2.95945632e+00 -2.70518081 0.92014041 878.75 -3.17596782e+00 -8.13879394e-01 3.27859288e+00 -2.89072922 0.92602128 879.00 -3.19986969e+00 -6.34257845e-01 3.26212340e+00 -2.94591533 0.93471717 879.25 -2.96263306e+00 -1.66678767e-01 2.96731806e+00 -3.08539155 0.90952854 879.50 -2.82773429e+00 6.39960641e-02 2.82845837e+00 3.11896495 0.89632080 879.75 -2.51725208e+00 2.57739618e-02 2.51738403e+00 3.13135408 0.88195838 880.00 -2.45604744e+00 -3.40605993e-03 2.45604980e+00 -3.14020585 0.88673649 880.25 -2.33953251e+00 -1.65748788e-01 2.34539656e+00 -3.07086386 0.87276744 880.50 -2.24164991e+00 -2.35024655e-01 2.25393676e+00 -3.03712981 0.84125431 880.75 -1.61537207e+00 -5.27791205e-01 1.69940886e+00 -2.82579644 0.73306552 881.00 -1.45887164e+00 -8.34817555e-01 1.68084110e+00 -2.62183875 0.69981937 881.25 -1.07374876e+00 -1.50797176e+00 1.85119292e+00 -2.18956273 0.51958223 881.50 -3.49977671e-01 -2.11203596e+00 2.14083635e+00 -1.73501045 0.46586253 881.75 8.36966045e-01 -3.65427704e+00 3.74890022e+00 -1.34564239 0.62509588 882.00 2.09757490e+00 -3.84978593e+00 4.38413870e+00 -1.07191183 0.54957286 882.25 4.77195733e+00 -1.82029277e+00 5.10735181e+00 -0.36441886 0.53019987 882.50 4.48837967e+00 3.13746765e-01 4.49933207e+00 0.06978849 0.50940332 882.75 3.62481632e+00 1.92228270e+00 4.10298234e+00 0.48760193 0.61336794 883.00 2.71644705e+00 2.67643302e+00 3.81344703e+00 0.77797851 0.64656055 883.25 2.20456534e+00 2.65301423e+00 3.44943370e+00 0.87745663 0.74256675 883.50 1.82445617e+00 2.45116592e+00 3.05562672e+00 0.93093920 0.75927415 883.75 1.53924054e+00 2.29571620e+00 2.76397799e+00 0.98015574 0.79857746 884.00 1.41101023e+00 2.04877878e+00 2.48765841e+00 0.96768919 0.78533905 884.25 1.13395396e+00 1.83361430e+00 2.15592045e+00 1.01693867 0.81672933 884.50 7.23190726e-01 1.82713193e+00 1.96504858e+00 1.19391024 0.80673572 884.75 4.21235701e-01 1.79508118e+00 1.84384271e+00 1.34030557 0.84778647 885.00 3.59058293e-01 1.82415414e+00 1.85915604e+00 1.37644540 0.84056531 885.25 1.42677843e-01 1.94291017e+00 1.94814191e+00 1.49749279 0.86307998 885.50 6.12860354e-02 2.10821782e+00 2.10910842e+00 1.54173444 0.91372310 885.75 1.28759973e-01 2.16640506e+00 2.17022810e+00 1.51143131 0.93784519 886.00 2.19123339e-01 2.08684985e+00 2.09832251e+00 1.46617772 0.89125598 886.25 3.07408855e-01 1.97799571e+00 2.00174105e+00 1.41661545 0.88518069 886.50 2.71525037e-01 1.58676601e+00 1.60982987e+00 1.40131928 0.84787046 886.75 1.59223074e-01 1.36374730e+00 1.37301081e+00 1.45456845 0.87871593 887.00 4.98348036e-04 1.31610078e+00 1.31610087e+00 1.57041767 0.91500764 887.25 -1.44964988e-01 1.30058405e+00 1.30863812e+00 1.68179960 0.94471672 887.50 -2.79293029e-01 1.29553096e+00 1.32529433e+00 1.78312861 0.93212006 887.75 -3.80585851e-01 1.30772460e+00 1.36197989e+00 1.85400271 0.94716517 888.00 -4.85960013e-01 1.28428851e+00 1.37315480e+00 1.93253443 0.91535925 888.25 -5.36577439e-01 1.25541612e+00 1.36527835e+00 1.97470652 0.86038646 888.50 -5.94058291e-01 1.17206084e+00 1.31401365e+00 2.03990840 0.83156113 888.75 -6.78094017e-01 1.08561645e+00 1.27999007e+00 2.12911987 0.75761292 889.00 -9.62146438e-01 1.01890534e+00 1.40138998e+00 2.32755143 0.61148727 889.25 -1.05748021e+00 1.03105206e+00 1.47693356e+00 2.36884775 0.52959137 889.50 -8.63079364e-01 1.10891898e+00 1.40520721e+00 2.23216914 0.46560004 889.75 -8.74541436e-01 1.21573471e+00 1.49760930e+00 2.19439261 0.39651223 890.00 -8.11812031e-01 1.00241421e+00 1.28991202e+00 2.25151872 0.16549944 890.25 -3.59589804e-01 8.60931586e-01 9.33010195e-01 1.96644651 0.07560636 890.50 3.08066885e-01 4.78415211e-01 5.69022249e-01 0.99869864 0.06846670 890.75 4.50230056e-01 2.06244723e-01 4.95221152e-01 0.42955904 0.07289945 891.00 7.19993882e-01 4.83264645e-01 8.67142380e-01 0.59113905 0.24705642 891.25 6.65157771e-01 5.84738694e-01 8.85637736e-01 0.72114614 0.32908972 891.50 3.55605505e-01 5.34326299e-01 6.41841000e-01 0.98358712 0.27402040 891.75 1.94679504e-01 6.10935501e-01 6.41203786e-01 1.26231117 0.33803898 892.00 5.87686343e-02 6.74902461e-01 6.77456334e-01 1.48393819 0.39573517 892.25 1.28326661e-02 6.99374646e-01 6.99492368e-01 1.55244961 0.33961365 892.50 -1.08240938e-01 6.35817936e-01 6.44965540e-01 1.73941865 0.21926118 892.75 -1.33238767e-01 3.74287511e-01 3.97295494e-01 1.91278833 0.10334833 893.00 -6.54759765e-01 2.81944790e-01 7.12883731e-01 2.73498159 0.22829874 893.25 -8.62175511e-01 3.86689599e-01 9.44920874e-01 2.71998308 0.34937938 893.50 -8.57115163e-01 5.20241780e-01 1.00264546e+00 2.59606511 0.42783453 893.75 -7.69072042e-01 5.29096339e-01 9.33495979e-01 2.53898813 0.36557491 894.00 -9.45584766e-01 7.23771513e-01 1.19078787e+00 2.48829422 0.48905382 894.25 -1.04914387e+00 8.72932515e-01 1.36481282e+00 2.44761653 0.58973571 894.50 -1.04492026e+00 6.62545415e-01 1.23726504e+00 2.57650256 0.55042096 894.75 -1.05447010e+00 7.64018851e-01 1.30216435e+00 2.51457791 0.55812728 895.00 -1.23799326e+00 8.22067543e-01 1.48607616e+00 2.55541604 0.66870677 895.25 -1.21110150e+00 9.33074802e-01 1.52885429e+00 2.48514100 0.71039409 895.50 -1.14187604e+00 8.85484683e-01 1.44497890e+00 2.48199226 0.67759926 895.75 -1.13599989e+00 8.91442608e-01 1.44401028e+00 2.47623805 0.74835338 896.00 -1.24766275e+00 1.00437479e+00 1.60169631e+00 2.46380730 0.81324094 896.25 -1.33050178e+00 1.01743367e+00 1.67493470e+00 2.48875023 0.82588657 896.50 -1.29264750e+00 9.95845524e-01 1.63176158e+00 2.48516778 0.81092786 896.75 -1.30561525e+00 1.13443856e+00 1.72961904e+00 2.42623258 0.81459556 897.00 -1.34411159e+00 1.07403545e+00 1.72051972e+00 2.46742076 0.85555041 897.25 -1.35872554e+00 1.15175028e+00 1.78119730e+00 2.43845308 0.87524911 897.50 -1.27929486e+00 1.15869990e+00 1.72603036e+00 2.40561902 0.87412507 897.75 -1.20703214e+00 1.18071405e+00 1.68849407e+00 2.36721619 0.85935994 898.00 -1.23312603e+00 1.26473816e+00 1.76639815e+00 2.34353950 0.85051900 898.25 -1.10184421e+00 1.32775500e+00 1.72539677e+00 2.26347834 0.77956256 898.50 -1.10316364e+00 1.38477932e+00 1.77047558e+00 2.24348205 0.73350348 898.75 -1.05910377e+00 1.35573117e+00 1.72038013e+00 2.23397129 0.69428776 899.00 -9.72904042e-01 1.28740482e+00 1.61367700e+00 2.21794151 0.66966077 899.25 -8.56440665e-01 1.17240539e+00 1.45190393e+00 2.20169937 0.61827560 899.50 -8.97908392e-01 1.18568315e+00 1.48730764e+00 2.21894802 0.63695478 899.75 -7.38155214e-01 1.16241842e+00 1.37698573e+00 2.13656632 0.66327908 900.00 -5.32548179e-01 1.14845709e+00 1.26592308e+00 2.00499077 0.63636276 900.25 -5.11572817e-01 9.65057505e-01 1.09226496e+00 2.05822960 0.52454954 900.50 -4.73917008e-01 1.05361859e+00 1.15529627e+00 1.99348342 0.51273394 900.75 -4.74812431e-01 1.14728736e+00 1.24165822e+00 1.96319067 0.52391965 901.00 -5.26239450e-01 1.11032624e+00 1.22871979e+00 2.01338785 0.54369510 901.25 -4.08648875e-01 1.27307836e+00 1.33705737e+00 1.88139951 0.64889554 901.50 -4.27871245e-01 1.21069364e+00 1.28407667e+00 1.91050578 0.68086919 901.75 -4.52568220e-01 1.36391454e+00 1.43703893e+00 1.89118036 0.80481485 902.00 -4.10007257e-01 1.40687718e+00 1.46540416e+00 1.85437299 0.79573075 902.25 -5.26178419e-01 1.42032455e+00 1.51465691e+00 1.92558388 0.84703780 902.50 -5.99267899e-01 1.47869412e+00 1.59551192e+00 1.95583610 0.88298661 902.75 -6.18370915e-01 1.49960046e+00 1.62209252e+00 1.96190979 0.92243750 903.00 -5.29805486e-01 1.54120180e+00 1.62972293e+00 1.90190248 0.91325558 903.25 -4.00146547e-01 1.70038185e+00 1.74683019e+00 1.80191859 0.93556118 903.50 -3.81034591e-01 1.75928155e+00 1.80007193e+00 1.78408729 0.94781712 903.75 -2.41045291e-01 1.79544869e+00 1.81155702e+00 1.70425185 0.95685021 904.00 -2.23482130e-01 1.82443779e+00 1.83807441e+00 1.69268282 0.96077119 904.25 -2.29175460e-01 1.90683646e+00 1.92055895e+00 1.69040882 0.95060003 904.50 -1.77778538e-01 1.93322867e+00 1.94138566e+00 1.66249781 0.94977091 904.75 -9.66653409e-02 1.92238041e+00 1.92480925e+00 1.62103820 0.96813783 905.00 -6.44469453e-02 1.99042585e+00 1.99146893e+00 1.60316349 0.96417072 905.25 9.04574191e-02 2.03162528e+00 2.03363808e+00 1.52630106 0.96733847 905.50 2.05213320e-01 1.99557489e+00 2.00609861e+00 1.46832234 0.97526108 905.75 2.57061006e-01 1.96681737e+00 1.98354504e+00 1.44083403 0.97912370 906.00 3.86400926e-01 1.96220725e+00 1.99989074e+00 1.37636254 0.97347152 906.25 5.17313954e-01 1.91065006e+00 1.97944370e+00 1.30638293 0.97641917 906.50 6.04085470e-01 1.76810096e+00 1.86844863e+00 1.24157256 0.96799151 906.75 7.07083235e-01 1.63888089e+00 1.78490820e+00 1.16348132 0.97076620 907.00 7.38602313e-01 1.56242934e+00 1.72821261e+00 1.12920430 0.96802885 907.25 7.79716045e-01 1.39450466e+00 1.59768594e+00 1.06096692 0.96226205 907.50 7.30920565e-01 1.21785851e+00 1.42036059e+00 1.03025279 0.94932634 907.75 7.19174592e-01 1.05587280e+00 1.27752865e+00 0.97285517 0.94091255 908.00 6.08307692e-01 8.38389172e-01 1.03582559e+00 0.94311645 0.89289364 908.25 5.20180871e-01 7.52843937e-01 9.15074933e-01 0.96616703 0.88110532 908.50 3.85610950e-01 7.07242814e-01 8.05535973e-01 1.07162164 0.89524066 908.75 3.13806729e-01 6.63003940e-01 7.33518158e-01 1.12872737 0.90511094 909.00 1.85020649e-01 6.53485359e-01 6.79172846e-01 1.29488848 0.89897317 909.25 1.45928891e-01 6.63575460e-01 6.79431845e-01 1.35432898 0.91668556 909.50 6.78875154e-02 6.68991713e-01 6.72427414e-01 1.46966515 0.92228312 909.75 4.70126391e-02 6.73447736e-01 6.75086692e-01 1.50110051 0.93722098 910.00 -1.02494332e-03 6.38501209e-01 6.38502032e-01 1.57240156 0.93266534 910.25 -1.98175458e-02 6.25584485e-01 6.25898301e-01 1.60246418 0.94192522 910.50 -6.28799120e-02 5.93429080e-01 5.96751167e-01 1.67636270 0.94762492 910.75 -9.42948408e-02 5.75416228e-01 5.83091204e-01 1.73322504 0.93777973 911.00 -1.17405553e-01 5.77111418e-01 5.88932639e-01 1.77149406 0.89852140 911.25 -1.55182794e-01 5.61262712e-01 5.82320815e-01 1.84054604 0.88704942 911.50 -2.40994976e-01 5.35443354e-01 5.87178136e-01 1.99372086 0.92054557 911.75 -2.71746144e-01 5.11131010e-01 5.78878982e-01 2.05944728 0.92670077 912.00 -3.22204409e-01 4.79267522e-01 5.77505878e-01 2.16267853 0.91362019 912.25 -3.30398069e-01 5.03777749e-01 6.02457388e-01 2.15126670 0.92623672 912.50 -3.55996360e-01 5.30262554e-01 6.38679720e-01 2.16204021 0.92558497 912.75 -3.54075198e-01 5.42606607e-01 6.47912939e-01 2.14895853 0.91883993 913.00 -3.54646966e-01 5.68396914e-01 6.69962329e-01 2.12863480 0.93349610 913.25 -3.65480677e-01 5.95597906e-01 6.98793955e-01 2.12118245 0.93958881 913.50 -3.57490895e-01 6.02214376e-01 7.00329848e-01 2.10651684 0.92921565 913.75 -3.33576515e-01 5.85891300e-01 6.74197232e-01 2.08837322 0.91361200 914.00 -2.65110544e-01 5.57667407e-01 6.17475941e-01 2.01456433 0.87944564 914.25 -2.76615036e-01 5.67510852e-01 6.31335446e-01 2.02432781 0.85874754 914.50 -2.58666688e-01 5.57247444e-01 6.14355898e-01 2.00538484 0.86945362 914.75 -1.93837005e-01 5.38882571e-01 5.72684215e-01 1.91608785 0.85699190 915.00 -1.14725622e-01 5.55405009e-01 5.67130225e-01 1.77449356 0.87548771 915.25 -8.79032616e-02 5.11070969e-01 5.18575471e-01 1.74112787 0.85523790 915.50 -6.08804660e-02 4.54430587e-01 4.58490555e-01 1.70397422 0.84085937 915.75 1.59337178e-02 4.23772920e-01 4.24072365e-01 1.53321437 0.78524856 916.00 1.14389248e-01 4.07308222e-01 4.23066056e-01 1.29700703 0.76180486 916.25 1.91951870e-01 3.29809320e-01 3.81601504e-01 1.04371083 0.64919672 916.50 3.15880285e-01 2.43460032e-01 3.98814671e-01 0.65664006 0.73285742 916.75 3.62749222e-01 1.38253349e-01 3.88202249e-01 0.36413102 0.69163161 917.00 3.93843746e-01 7.10558238e-02 4.00202232e-01 0.17849613 0.71249730 917.25 4.60223909e-01 4.05304753e-02 4.62005157e-01 0.08784024 0.74327826 917.50 5.20576758e-01 -1.33283720e-02 5.20747354e-01 -0.02559749 0.76292078 917.75 6.46373808e-01 -1.32986133e-02 6.46510598e-01 -0.02057128 0.77508742 918.00 7.26362215e-01 -4.22528811e-02 7.27590114e-01 -0.05810506 0.80180657 918.25 8.49516364e-01 1.28366285e-02 8.49613342e-01 0.01510936 0.81094432 918.50 9.77488966e-01 6.87446127e-02 9.79903312e-01 0.07021216 0.83213157 918.75 1.11011444e+00 1.07976280e-01 1.11535329e+00 0.09696090 0.81260163 919.00 1.25170726e+00 1.10715514e-01 1.25659420e+00 0.08822201 0.81720429 919.25 1.47740094e+00 2.82544400e-01 1.50417581e+00 0.18896255 0.82279201 919.50 1.53417070e+00 3.07998628e-01 1.56478206e+00 0.19812529 0.79552932 919.75 1.49909055e+00 4.03996726e-01 1.55257394e+00 0.26324066 0.57502480 920.00 1.68024083e+00 7.44402666e-01 1.83775531e+00 0.41704535 0.61175359 920.25 1.60491700e+00 9.22716799e-01 1.85126035e+00 0.52178255 0.53369347 920.50 1.41218319e+00 8.71529540e-01 1.65946530e+00 0.55293480 0.44397249 920.75 1.73200182e+00 1.09690637e+00 2.05013021e+00 0.56455781 0.46326888 921.00 1.55343997e+00 1.14185058e+00 1.92795189e+00 0.63386196 0.41421846 921.25 1.50568468e+00 6.44849604e-01 1.63796134e+00 0.40464273 0.29907492 921.50 1.53527259e+00 7.77486219e-01 1.72091451e+00 0.46876703 0.39761129 921.75 1.33270335e+00 1.10139711e+00 1.72892273e+00 0.69065526 0.58603793 922.00 1.39966945e+00 1.04580739e+00 1.74722285e+00 0.64169495 0.64498202 922.25 1.48956824e+00 1.17426014e+00 1.89676051e+00 0.66757984 0.72042415 922.50 1.48703948e+00 1.25975287e+00 1.94891347e+00 0.70284005 0.83029828 922.75 1.39100963e+00 1.44337011e+00 2.00455109e+00 0.80386941 0.88928595 923.00 1.20238778e+00 1.59263218e+00 1.99554845e+00 0.92412269 0.88115657 923.25 8.61496452e-01 1.69427955e+00 1.90072600e+00 1.10039283 0.86386089 923.50 8.37227139e-01 1.70125084e+00 1.89610224e+00 1.11346898 0.85478817 923.75 7.53957459e-01 1.63374523e+00 1.79932635e+00 1.13842831 0.85736630 924.00 7.06210605e-01 1.50830492e+00 1.66544803e+00 1.13289869 0.85156163 924.25 4.16740711e-01 1.39531007e+00 1.45621530e+00 1.28055789 0.88210155 924.50 2.66684950e-01 1.36822111e+00 1.39396911e+00 1.37829625 0.87169443 924.75 -2.45907883e-02 1.27014733e+00 1.27038535e+00 1.59015449 0.86396719 925.00 -1.31554524e-01 1.27530065e+00 1.28206799e+00 1.67358844 0.86673290 925.25 -3.27542403e-01 1.17277789e+00 1.21765841e+00 1.84314436 0.81696982 925.50 -4.16799367e-01 1.23044976e+00 1.29912598e+00 1.89740264 0.81274686 925.75 -4.80218043e-01 1.30501572e+00 1.39056657e+00 1.92339721 0.79392609 926.00 -6.54039731e-01 1.40134868e+00 1.54646245e+00 2.00746861 0.79840041 926.25 -7.63852737e-01 1.39968783e+00 1.59455230e+00 2.07035592 0.80803721 926.50 -8.11351945e-01 1.38568345e+00 1.60574300e+00 2.10050426 0.75485588 926.75 -7.74709331e-01 1.54251688e+00 1.72613234e+00 2.03623208 0.67710707 927.00 -6.94786947e-01 1.46324850e+00 1.61982255e+00 2.01410186 0.62654431 927.25 -7.73667355e-01 1.40163377e+00 1.60098045e+00 2.07515489 0.62606561 927.50 -7.19770063e-01 1.55277868e+00 1.71148782e+00 2.00485026 0.62587199 927.75 -7.95855231e-01 1.52716882e+00 1.72210051e+00 2.05120559 0.58513308 928.00 -7.05616968e-01 1.71905558e+00 1.85823772e+00 1.96029397 0.66636623 928.25 -6.01557124e-01 1.84793157e+00 1.94337904e+00 1.88550750 0.72592576 928.50 -8.07764940e-01 1.94916327e+00 2.10991034e+00 1.96366840 0.68486906 928.75 -8.12091725e-01 1.89647545e+00 2.06303468e+00 1.97538361 0.56581079 929.00 -5.31855948e-01 2.02367437e+00 2.09239783e+00 1.82780116 0.43450200 929.25 -5.37520003e-01 2.26669789e+00 2.32955942e+00 1.80363334 0.57842033 929.50 -1.13227403e-01 2.72362656e+00 2.72597911e+00 1.61234470 0.72029679 929.75 1.92970635e-02 2.76293399e+00 2.76300137e+00 1.56381218 0.74337254 930.00 1.13801880e-01 2.77377463e+00 2.77610817e+00 1.52979152 0.62867942 930.25 -9.87460375e-02 2.54381670e+00 2.54573255e+00 1.60959491 0.62628587 930.50 1.09274397e-01 2.18243276e+00 2.18516673e+00 1.52076811 0.62946648 930.75 3.37942376e-01 2.22670486e+00 2.25220327e+00 1.42017781 0.64771795 931.00 5.67205393e-01 2.36906361e+00 2.43601813e+00 1.33579816 0.75574082 931.25 5.59523353e-01 2.42761956e+00 2.49126537e+00 1.34426991 0.76597347 931.50 -9.58300361e-02 2.31388062e+00 2.31586418e+00 1.61218796 0.60411692 931.75 -1.56537044e-01 2.39881644e+00 2.40391850e+00 1.63595988 0.66313350 932.00 -1.34206564e-01 2.69575721e+00 2.69909584e+00 1.62053962 0.75920488 932.25 2.51872515e-02 2.84397290e+00 2.84408443e+00 1.56194020 0.76730652 932.50 2.12910300e-01 2.84256250e+00 2.85052493e+00 1.49603509 0.63363017 932.75 2.03309204e-01 2.50298837e+00 2.51123185e+00 1.48974767 0.49703661 933.00 7.77667182e-01 3.05140802e+00 3.14894540e+00 1.32125332 0.58198416 933.25 9.52401047e-01 3.12298578e+00 3.26498208e+00 1.27479083 0.61508279 933.50 1.39046200e+00 2.79899160e+00 3.12533815e+00 1.10973407 0.62739981 933.75 9.84183098e-01 2.59635302e+00 2.77662842e+00 1.20846776 0.55477277 934.00 9.03399611e-01 2.52880546e+00 2.68532827e+00 1.22768303 0.55392362 934.25 1.06959632e+00 2.58576242e+00 2.79825009e+00 1.17857979 0.54326720 934.50 5.60626005e-01 2.38575908e+00 2.45074436e+00 1.33999524 0.26429981 934.75 5.56863821e-01 1.95084268e+00 2.02876427e+00 1.29274303 0.16898060 935.00 -1.42069375e-02 2.40596147e+00 2.40600341e+00 1.57670115 0.17782797 935.25 5.06712695e-01 3.21177409e+00 3.25149974e+00 1.41431886 0.26051977 935.50 1.33797334e+00 1.62524501e+00 2.10513515e+00 0.88204198 0.10298983 935.75 1.20076675e+00 1.21186886e-01 1.20686662e+00 0.10058400 0.02891514 936.00 1.10857193e+00 -3.71363552e-01 1.16912045e+00 -0.32324328 0.02586152 936.25 7.09155181e-01 -3.87644502e-02 7.10213879e-01 -0.05460851 0.00891368 936.50 2.09847995e+00 -6.85190375e-02 2.09959829e+00 -0.03264015 0.08315290 936.75 2.86701324e+00 -1.03170331e+00 3.04699469e+00 -0.34542544 0.18199934 937.00 2.16703764e+00 -2.06842085e+00 2.99573312e+00 -0.76211875 0.17220834 937.25 2.19263691e+00 -2.51632614e+00 3.33759702e+00 -0.85402917 0.23378014 937.50 2.69685609e+00 -1.72890736e+00 3.20345960e+00 -0.57008079 0.22316506 937.75 2.02819639e+00 -1.67015030e+00 2.62735278e+00 -0.68888646 0.14284841 938.00 1.24370384e+00 -1.50841152e+00 1.95502035e+00 -0.88128655 0.06868470 938.25 1.02235920e+00 -2.11373977e+00 2.34800216e+00 -1.12029529 0.08753013 938.50 8.48825443e-01 -3.47448827e+00 3.57667071e+00 -1.33118736 0.26629936 938.75 3.90381563e-01 -3.14975552e+00 3.17385532e+00 -1.44748489 0.26846034 939.00 5.35211100e-02 -3.57214575e+00 3.57254667e+00 -1.55581455 0.29146361 939.25 -1.14814853e-01 -3.26758576e+00 3.26960229e+00 -1.60591939 0.24627209 939.50 -9.90853936e-01 -3.60897714e+00 3.74252689e+00 -1.83874651 0.24437610 939.75 -1.02225111e+00 -4.08326510e+00 4.20928155e+00 -1.81610569 0.27464093 940.00 -1.58212701e-01 -3.82729266e+00 3.83056136e+00 -1.61211082 0.28872782 940.25 -1.32243471e+00 -3.76560416e+00 3.99106605e+00 -1.90852904 0.31128421 940.50 -1.08637496e+00 -2.84954186e+00 3.04960643e+00 -1.93503121 0.21693816 940.75 -2.53047416e+00 -2.43970711e+00 3.51503488e+00 -2.37445478 0.29345966 941.00 -2.84169563e+00 -2.52248566e+00 3.79975894e+00 -2.41563207 0.32503773 941.25 -2.42191702e+00 -3.06772154e+00 3.90852881e+00 -2.23909209 0.33604088 941.50 -2.90629906e+00 -3.13560449e+00 4.27534674e+00 -2.31826018 0.38862896 941.75 -4.09948841e+00 -1.87772121e+00 4.50906223e+00 -2.71207452 0.55396932 942.00 -4.39590851e+00 -1.95014669e+00 4.80906267e+00 -2.72405057 0.64844534 942.25 -4.92383158e+00 -1.71566097e+00 5.21417395e+00 -2.80630807 0.73193533 942.50 -4.67390450e+00 -1.86299869e+00 5.03151542e+00 -2.76229738 0.71180829 942.75 -4.12936331e+00 -2.11180521e+00 4.63803435e+00 -2.66885732 0.70743924 943.00 -4.09403591e+00 -2.49022493e+00 4.79190466e+00 -2.59512413 0.79242506 943.25 -4.22369481e+00 -2.61552240e+00 4.96795282e+00 -2.58713896 0.82650880 943.50 -4.34320588e+00 -2.25455857e+00 4.89351322e+00 -2.66278199 0.85129466 943.75 -4.20983412e+00 -1.54197416e+00 4.48334558e+00 -2.79048956 0.83226101 944.00 -4.46383647e+00 -1.54372150e+00 4.72323110e+00 -2.80863899 0.84053078 944.25 -4.49442858e+00 -1.70714367e+00 4.80772584e+00 -2.77858937 0.87523250 944.50 -4.45108142e+00 -1.24669235e+00 4.62237684e+00 -2.86850280 0.85019478 944.75 -4.24157746e+00 -2.45090823e-01 4.24865259e+00 -3.08387389 0.82363686 945.00 -4.12727854e+00 -5.65593093e-02 4.12766606e+00 -3.12788973 0.85775063 945.25 -3.82239979e+00 1.35013860e-01 3.82478351e+00 3.10628558 0.91607729 945.50 -3.59009479e+00 3.46624999e-01 3.60678936e+00 3.04534062 0.88879663 945.75 -3.06823561e+00 5.31457353e-01 3.11392303e+00 2.97008171 0.87620513 946.00 -2.82559474e+00 6.21017982e-01 2.89303456e+00 2.92524924 0.86558082 946.25 -2.53002207e+00 6.29235956e-01 2.60709601e+00 2.89783065 0.85117128 946.50 -2.32271598e+00 5.32736565e-01 2.38302702e+00 2.91613284 0.86260482 946.75 -2.26759156e+00 5.34641236e-01 2.32976667e+00 2.91004645 0.93150872 947.00 -2.02312566e+00 5.39679519e-01 2.09386996e+00 2.88090750 0.89530035 947.25 -1.89554346e+00 4.02621504e-01 1.93783103e+00 2.93229887 0.91076758 947.50 -1.78372629e+00 4.01701590e-01 1.82839920e+00 2.92008443 0.91196435 947.75 -1.59255758e+00 4.06917416e-01 1.64372182e+00 2.89143308 0.89954088 948.00 -1.41403596e+00 2.65063012e-01 1.43866469e+00 2.95629166 0.90117448 948.25 -1.37947454e+00 9.08799901e-02 1.38246489e+00 3.07580757 0.92132619 948.50 -1.32355920e+00 3.07462082e-02 1.32391627e+00 3.11836689 0.88468246 948.75 -1.25326184e+00 -7.90613412e-02 1.25575313e+00 -3.07859168 0.88017121 949.00 -1.26724310e+00 -1.07468728e-01 1.27179189e+00 -3.05698994 0.87370588 949.25 -1.29285699e+00 -6.46207104e-02 1.29447095e+00 -3.09165134 0.88756668 949.50 -1.24349770e+00 -4.79914852e-02 1.24442345e+00 -3.10301785 0.89890903 949.75 -1.20867045e+00 -1.22701316e-02 1.20873273e+00 -3.13144124 0.89439311 950.00 -1.12479643e+00 -8.26581989e-02 1.12782950e+00 -3.06823726 0.89540176 950.25 -1.05039489e+00 -2.93027323e-02 1.05080353e+00 -3.11370301 0.89916482 950.50 -1.07535113e+00 1.15609634e-01 1.08154780e+00 3.03449527 0.86662514 950.75 -9.98613909e-01 1.07931322e-01 1.00442964e+00 3.03392945 0.85146571 951.00 -8.39896214e-01 -1.77304315e-03 8.39898085e-01 -3.13948163 0.88361508 951.25 -7.92926399e-01 -2.61108170e-02 7.93356193e-01 -3.10867486 0.92065666 951.50 -7.35110768e-01 -3.65474448e-02 7.36018720e-01 -3.09191663 0.90078375 951.75 -7.03688700e-01 -9.72865881e-02 7.10381917e-01 -3.00421122 0.90191054 952.00 -7.41705481e-01 -2.04763617e-01 7.69451207e-01 -2.87223071 0.91633826 952.25 -7.54187163e-01 -2.34878745e-01 7.89915376e-01 -2.83968018 0.92802395 952.50 -7.04885838e-01 -2.54749884e-01 7.49507537e-01 -2.79479305 0.92643671 952.75 -7.02571958e-01 -2.44811288e-01 7.44002636e-01 -2.80629923 0.92703314 953.00 -7.13147946e-01 -2.56257765e-01 7.57791551e-01 -2.79662746 0.92119260 953.25 -7.06668227e-01 -2.37350217e-01 7.45463016e-01 -2.81755886 0.92078656 953.50 -6.86964043e-01 -2.39798137e-01 7.27614420e-01 -2.80574710 0.93645879 953.75 -6.65448790e-01 -2.33853923e-01 7.05343710e-01 -2.80365081 0.92714437 954.00 -6.30838730e-01 -2.69880726e-01 6.86143651e-01 -2.73734216 0.90528696 954.25 -6.11495318e-01 -2.60878677e-01 6.64818929e-01 -2.73834713 0.86848015 954.50 -5.73293996e-01 -2.77661721e-01 6.36994535e-01 -2.69056193 0.90172993 954.75 -5.43700014e-01 -2.72598453e-01 6.08210179e-01 -2.67684439 0.87926165 955.00 -5.01446043e-01 -2.87507056e-01 5.78021143e-01 -2.62099482 0.83810444 955.25 -4.96757472e-01 -2.96247995e-01 5.78386429e-01 -2.60385138 0.80801074 955.50 -5.06242741e-01 -3.25582351e-01 6.01901637e-01 -2.57005870 0.81029534 955.75 -4.73075534e-01 -3.37477000e-01 5.81112026e-01 -2.52195103 0.74967217 956.00 -4.27892976e-01 -3.80647818e-01 5.72699887e-01 -2.41456074 0.71746727 956.25 -4.01491351e-01 -3.94219020e-01 5.62675697e-01 -2.36533366 0.71370061 956.50 -4.52311578e-01 -3.44361228e-01 5.68480800e-01 -2.49087570 0.70246178 956.75 -4.26260250e-01 -3.50844221e-01 5.52077412e-01 -2.45293901 0.61342883 957.00 -4.04583528e-01 -3.95211084e-01 5.65579023e-01 -2.36791252 0.68563178 957.25 -4.19272764e-01 -3.65180212e-01 5.56009207e-01 -2.42504127 0.68634243 957.50 -3.97790807e-01 -3.41072860e-01 5.23992578e-01 -2.43280799 0.63900154 957.75 -3.69674867e-01 -3.10391636e-01 4.82703299e-01 -2.44314738 0.51301344 958.00 -3.52799574e-01 -2.48598575e-01 4.31588682e-01 -2.52775581 0.49924135 958.25 -3.95786358e-01 -2.55375117e-01 4.71023664e-01 -2.56857463 0.47165998 958.50 -3.88169475e-01 -2.68199236e-01 4.71811797e-01 -2.53697764 0.38161819 958.75 -4.01060996e-01 -1.55207694e-01 4.30045755e-01 -2.77234948 0.31059695 959.00 -3.78726398e-01 -3.83372052e-02 3.80661826e-01 -3.04070964 0.22445384 959.25 -4.59753647e-01 3.63379356e-02 4.61187447e-01 3.06271878 0.28093243 959.50 -3.91088337e-01 1.01225916e-01 4.03976204e-01 2.88831957 0.27143061 959.75 -3.66786973e-01 6.11957836e-02 3.71856972e-01 2.97627256 0.16569647 960.00 -3.65694642e-01 6.48521163e-02 3.71400549e-01 2.96607788 0.12867275 960.25 -3.62338323e-01 7.93927483e-02 3.70934319e-01 2.92588932 0.10157316 960.50 -3.50582312e-01 2.02261612e-01 4.04744015e-01 2.61830880 0.14788215 960.75 -3.15019877e-01 8.80881933e-02 3.27104039e-01 2.86892948 0.15128344 961.00 -3.23040503e-01 1.06069586e-01 3.40008711e-01 2.82433592 0.17556185 961.25 -3.80660215e-01 7.65410654e-02 3.88279196e-01 2.94316413 0.22059529 961.50 -3.95712885e-01 1.89662580e-01 4.38817253e-01 2.69464711 0.24164796 961.75 -4.90523748e-01 1.40481349e-01 5.10243625e-01 2.86266791 0.31276672 962.00 -4.32985110e-01 2.72728684e-02 4.33843192e-01 3.07868775 0.23685806 962.25 -5.75880616e-01 1.07569730e-01 5.85841046e-01 2.95692902 0.29397830 962.50 -7.18795321e-01 1.41674240e-01 7.32624258e-01 2.94698753 0.35023061 962.75 -4.43055212e-01 1.32572727e-01 4.62464538e-01 2.85084799 0.14505772 963.00 -3.46196762e-01 1.39029067e-01 3.73070074e-01 2.75971656 0.13790443 963.25 -3.33059611e-01 2.04363810e-01 3.90759864e-01 2.59123654 0.18112259 963.50 -2.58664515e-01 1.39670684e-01 2.93964677e-01 2.64648380 0.11230704 963.75 -1.33565786e-01 8.58351549e-02 1.58768677e-01 2.57040651 0.03063191 964.00 -8.49360148e-02 4.58926226e-04 8.49372546e-02 3.13618951 0.00974496 964.25 -8.89920114e-02 -4.26164503e-02 9.86698532e-02 -2.69498375 0.02062017 964.50 -9.08612752e-02 1.54133495e-02 9.21593331e-02 2.97355623 0.01777255 964.75 2.28945924e-02 -9.42570222e-02 9.69976732e-02 -1.33251549 0.02562431 965.00 5.15668701e-02 -5.16359099e-02 7.29754019e-02 -0.78606713 0.01351774 965.25 1.78062489e-02 -1.46168519e-01 1.47249104e-01 -1.44957363 0.04448462 965.50 7.54079728e-02 -1.29641497e-01 1.49977599e-01 -1.04396725 0.04559292 965.75 1.54675904e-01 -1.09156683e-01 1.89314069e-01 -0.61454942 0.06455077 966.00 1.13283532e-01 -1.49403491e-01 1.87495498e-01 -0.92204317 0.05467708 966.25 1.28148393e-01 -2.81282964e-01 3.09098878e-01 -1.14330735 0.13664989 966.50 1.13186905e-01 -4.02081402e-01 4.17708905e-01 -1.29639493 0.24828142 966.75 -9.42960549e-03 -3.05161027e-01 3.05306682e-01 -1.60168692 0.23291488 967.00 -6.51701769e-02 -3.40380567e-01 3.46563244e-01 -1.75996961 0.24554776 967.25 -1.44581133e-01 -3.74445104e-01 4.01388640e-01 -1.93928113 0.32442987 967.50 -1.59008836e-01 -3.68286700e-01 4.01146985e-01 -1.97837278 0.30055333 967.75 -1.55420566e-01 -2.41050032e-01 2.86811210e-01 -2.14348243 0.22775419 968.00 -1.04751312e-01 -2.58164918e-01 2.78607182e-01 -1.95625273 0.19387989 968.25 -1.24493568e-01 -2.67403365e-01 2.94963062e-01 -2.00651821 0.21042548 968.50 -1.09684521e-01 -1.31839617e-01 1.71500376e-01 -2.26472013 0.06676636 968.75 -8.07511312e-02 -5.70628920e-02 9.88783031e-02 -2.52641666 0.02836845 969.00 3.31385676e-02 -7.88520780e-02 8.55325369e-02 -1.17294526 0.01472881 969.25 2.74168758e-02 -1.25931301e-01 1.28881254e-01 -1.35642853 0.03779031 969.50 -3.66537970e-02 -2.08475671e-01 2.11673348e-01 -1.74483568 0.08860216 969.75 2.88214994e-02 -2.41807615e-01 2.43519201e-01 -1.45216414 0.09911129 970.00 2.06728533e-01 -2.08372367e-01 2.93522963e-01 -0.78935823 0.14424965 970.25 2.40627231e-01 -2.00403833e-01 3.13150380e-01 -0.69444669 0.13863440 970.50 1.97925428e-02 -3.26704349e-01 3.27303340e-01 -1.51028785 0.11922741 970.75 -6.26175605e-02 -3.13637791e-01 3.19827489e-01 -1.76785464 0.12168727 971.00 -1.27040539e-01 -1.82152853e-01 2.22078726e-01 -2.17980156 0.06511198 971.25 -9.43199112e-02 -1.27105211e-01 1.58278174e-01 -2.20919755 0.03785612 971.50 -1.19237086e-01 -1.59321559e-01 1.98999603e-01 -2.21327599 0.05242104 971.75 -1.52381349e-01 -1.40088629e-01 2.06990095e-01 -2.39820047 0.04549305 972.00 -1.41282454e-01 -1.50500536e-04 1.41282534e-01 -3.14052741 0.02067329 972.25 -2.66513714e-02 -2.97284998e-02 3.99259227e-02 -2.30167009 0.00174722 972.50 1.44084783e-01 3.94330913e-02 1.49383377e-01 0.26713840 0.02273982 972.75 1.57843036e-01 -1.24063443e-01 2.00763946e-01 -0.66614123 0.04662086 973.00 1.71150785e-02 -2.23795832e-01 2.24449326e-01 -1.49446859 0.06673657 973.25 -3.50483624e-03 -2.34873985e-01 2.34900134e-01 -1.58571742 0.09637625 973.50 3.71993195e-02 -3.20586680e-01 3.22737678e-01 -1.45527779 0.19079194 973.75 9.53860275e-02 -3.10751738e-01 3.25061743e-01 -1.27297335 0.15493959 974.00 7.32923684e-02 -9.17684831e-02 1.17444565e-01 -0.89686932 0.02878863 974.25 4.84422840e-02 -4.30877542e-02 6.48321636e-02 -0.72696451 0.01156730 974.50 3.31243704e-02 -1.49507524e-02 3.63421094e-02 -0.42397772 0.00424149 974.75 2.46037918e-02 -2.37834631e-02 3.42198727e-02 -0.76844638 0.00393131 975.00 8.31568850e-02 4.10823350e-03 8.32583036e-02 0.04936327 0.01959677 975.25 8.74306845e-02 -7.70284824e-02 1.16522580e-01 -0.72223134 0.03739794 975.50 5.36488061e-03 -8.10027230e-02 8.11801889e-02 -1.50466205 0.01860853 975.75 3.53851951e-02 1.70512570e-02 3.92792235e-02 0.44904312 0.00383364 976.00 5.66292722e-02 7.37549332e-02 9.29874434e-02 0.91599821 0.02342182 976.25 -5.16808673e-03 5.22350679e-02 5.24901080e-02 1.66941440 0.00558384 976.50 4.88432098e-02 1.55436436e-01 1.62929877e-01 1.26633370 0.03371276 976.75 2.03406911e-01 1.27195774e-01 2.39902348e-01 0.55883422 0.07344147 977.00 1.71871527e-01 7.63817541e-03 1.72041168e-01 0.04441197 0.04624302 977.25 1.96076098e-01 1.28530379e-01 2.34448063e-01 0.58024085 0.06461919 977.50 3.98620075e-01 1.50920018e-01 4.26233288e-01 0.36192849 0.14441032 977.75 3.49431384e-01 1.42512838e-01 3.77375411e-01 0.38724849 0.09508364 978.00 3.34121390e-01 4.27617090e-02 3.36846652e-01 0.12729058 0.06923085 978.25 1.92315138e-01 1.33944884e-01 2.34363701e-01 0.60836397 0.04914537 978.50 2.39279396e-01 3.54886866e-01 4.28017893e-01 0.97756803 0.15573565 978.75 2.30794933e-01 2.83404275e-01 3.65491839e-01 0.88735654 0.09417385 979.00 1.50711951e-01 3.58804821e-01 3.89172188e-01 1.17313534 0.09791163 979.25 1.99278083e-01 2.38538547e-01 3.10825342e-01 0.87483226 0.05569400 979.50 1.29329416e-01 8.73638808e-02 1.56072245e-01 0.59410296 0.01144960 979.75 -1.11398203e-01 -9.46801323e-02 1.46198109e-01 -2.43714206 0.00772681 980.00 -3.80072469e-01 -1.03517860e-01 3.93917541e-01 -2.87567924 0.06627281 980.25 -2.11527810e-01 -4.89143179e-02 2.17109707e-01 -2.91434407 0.02555101 980.50 -5.87399152e-02 6.93391858e-02 9.08751909e-02 2.27362697 0.00356287 980.75 3.57008884e-01 -2.23678766e-01 4.21292694e-01 -0.55970278 0.14458658 981.00 4.32666774e-01 -3.17946416e-01 5.36926868e-01 -0.63373625 0.27079864 981.25 2.10225583e-01 -2.21450879e-01 3.05344539e-01 -0.81139626 0.05463074 981.50 2.37478456e-01 -3.11532642e-01 3.91725164e-01 -0.91947542 0.05833248 981.75 3.77277630e-01 -4.36557628e-01 5.76993044e-01 -0.85811004 0.15162008 982.00 4.87435698e-01 -6.00173979e-01 7.73176801e-01 -0.88868621 0.25481102 982.25 4.22704801e-01 -6.27393104e-01 7.56506084e-01 -0.97790732 0.22696108 982.50 2.23220363e-01 -4.86763775e-01 5.35505652e-01 -1.14082983 0.11390854 982.75 3.02944566e-01 -4.89608659e-01 5.75753462e-01 -1.01670519 0.20778085 983.00 3.35522649e-01 -4.40112959e-01 5.53421055e-01 -0.91943432 0.21032813 983.25 2.00444293e-01 -4.67721535e-01 5.08862800e-01 -1.16591862 0.17878087 983.50 9.39299545e-02 -4.37360822e-01 4.47333572e-01 -1.35924445 0.12835643 983.75 2.60431201e-02 -1.29032041e-01 1.31634006e-01 -1.37163743 0.01678677 984.00 -5.43518664e-02 -2.15651234e-01 2.22395099e-01 -1.81769027 0.05060565 984.25 -1.45273933e-01 -2.68953357e-01 3.05680264e-01 -2.06604220 0.10030111 984.50 -9.55447623e-02 -3.35276545e-01 3.48624674e-01 -1.84841051 0.11377429 984.75 4.31668957e-02 -3.52231509e-01 3.54866759e-01 -1.44885178 0.12771770 985.00 1.64599392e-01 -2.13198611e-01 2.69344775e-01 -0.91333367 0.06583467 985.25 4.52877456e-01 2.95875245e-02 4.53842938e-01 0.06523958 0.14700910 985.50 4.32533276e-01 -4.98196924e-03 4.32561967e-01 -0.01151761 0.14876935 985.75 4.88659338e-01 -1.13081133e-01 5.01572817e-01 -0.22740806 0.19004293 986.00 5.47566351e-01 -4.43576646e-02 5.49360093e-01 -0.08083224 0.20131667 986.25 6.58568628e-01 1.92352936e-01 6.86084754e-01 0.28417249 0.21807992 986.50 7.72115789e-01 8.33862134e-02 7.76605467e-01 0.10758008 0.25582402 986.75 7.65560238e-01 -9.15884899e-02 7.71019410e-01 -0.11906998 0.29897540 987.00 7.29169611e-01 -4.57349822e-02 7.30602498e-01 -0.06263995 0.27657461 987.25 5.88931668e-01 -7.24901922e-02 5.93376219e-01 -0.12247159 0.13361276 987.50 4.60425961e-01 -1.12063514e-01 4.73867383e-01 -0.23874878 0.07904137 987.75 2.69772210e-01 -1.52661141e-01 3.09971724e-01 -0.51496021 0.04726478 988.00 -2.73884359e-02 -5.03115264e-02 5.72832970e-02 -2.06931218 0.00121458 988.25 -1.48933188e-01 -2.96439477e-02 1.51854727e-01 -2.94511849 0.00435734 988.50 -2.76622120e-01 -2.63362474e-02 2.77872984e-01 -3.04667217 0.01443787 988.75 -6.86818359e-01 -2.62929341e-01 7.35425928e-01 -2.77598183 0.15043967 989.00 -8.27379259e-01 -3.67307084e-01 9.05246338e-01 -2.72378930 0.19597440 989.25 -8.21648537e-01 -2.33882243e-01 8.54287552e-01 -2.86427725 0.14302987 989.50 -5.70990490e-01 -4.18891398e-01 7.08166748e-01 -2.50865589 0.11357204 989.75 -7.75780558e-01 -6.96332698e-01 1.04245609e+00 -2.41011076 0.23715579 990.00 -9.68441221e-01 -5.83160220e-01 1.13046638e+00 -2.59958366 0.30720941 990.25 -7.24250958e-01 -4.80452252e-01 8.69122440e-01 -2.55587018 0.25550806 990.50 -9.49737165e-01 -6.76887250e-01 1.16626628e+00 -2.52238727 0.35368156 990.75 -1.09601997e+00 -7.95065655e-01 1.35402702e+00 -2.51401469 0.37985188 991.00 -8.84568935e-01 -4.35160836e-01 9.85812941e-01 -2.68440835 0.27542135 991.25 -7.17145731e-01 -5.94905256e-01 9.31778012e-01 -2.44909379 0.27793383 991.50 -1.08394272e+00 -7.50728612e-01 1.31853148e+00 -2.53585672 0.48729155 991.75 -8.59570016e-01 -7.44685451e-01 1.13728494e+00 -2.42768484 0.48541679 992.00 -7.58301541e-01 -6.82403993e-01 1.02014530e+00 -2.40882666 0.42313692 992.25 -6.97929566e-01 -5.68522028e-01 9.00179412e-01 -2.45802227 0.38166474 992.50 -5.39940652e-01 -3.08896852e-01 6.22055603e-01 -2.62194499 0.28370983 992.75 -4.44099126e-01 -2.88557728e-01 5.29612685e-01 -2.56538636 0.19936006 993.00 -5.79107577e-01 -3.39942600e-01 6.71510653e-01 -2.61077853 0.33699610 993.25 -4.94599765e-01 -3.16561166e-01 5.87230704e-01 -2.57225463 0.30288507 993.50 -4.91795850e-01 -2.27773558e-01 5.41981506e-01 -2.70785999 0.34117692 993.75 -5.00487656e-01 -2.27933871e-01 5.49947037e-01 -2.71423766 0.32573368 994.00 -5.45389990e-01 -2.20717557e-01 5.88359143e-01 -2.75704392 0.28003097 994.25 -4.74632445e-01 -1.84200148e-01 5.09122434e-01 -2.77139542 0.24478092 994.50 -3.62339326e-01 -1.13867712e-01 3.79810009e-01 -2.83710780 0.22506990 994.75 -4.22878852e-01 -1.88389396e-01 4.62943936e-01 -2.72249341 0.28783687 995.00 -2.22372945e-01 -2.59729853e-01 3.41920054e-01 -2.27886159 0.17832874 995.25 -2.29377395e-01 -2.50568539e-01 3.39703667e-01 -2.31206996 0.17550123 995.50 -3.04456116e-01 -1.83208915e-01 3.55329471e-01 -2.59988148 0.19020612 995.75 -3.65367358e-01 -1.40192996e-01 3.91340495e-01 -2.77521281 0.21340368 996.00 -3.25259275e-01 -1.45329207e-01 3.56250157e-01 -2.72139442 0.14658847 996.25 -2.78248296e-01 -1.02526916e-01 2.96536478e-01 -2.78855674 0.07734454 996.50 -2.96469674e-01 -1.86153651e-01 3.50067779e-01 -2.58090983 0.10706357 996.75 -4.14180136e-01 -5.95132838e-02 4.18434004e-01 -2.99888011 0.21347134 997.00 -5.71863958e-01 1.59072809e-02 5.72085158e-01 3.11378328 0.39759842 997.25 -5.69811588e-01 1.17891237e-02 5.69933531e-01 3.12090609 0.37340920 997.50 -5.83536583e-01 -3.77269685e-02 5.84754878e-01 -3.07703023 0.43442354 997.75 -6.36812469e-01 -3.56093581e-02 6.37807296e-01 -3.08573270 0.51532993 998.00 -6.14577679e-01 7.48717643e-02 6.19121559e-01 3.02036368 0.51315748 998.25 -5.77312869e-01 1.70331208e-01 6.01915998e-01 2.85469120 0.43052343 998.50 -6.41975551e-01 1.10707316e-01 6.51451240e-01 2.97082435 0.44985902 998.75 -6.75391379e-01 1.54908106e-01 6.92928593e-01 2.91613172 0.38877877 999.00 -5.66484323e-01 5.01132397e-01 7.56332048e-01 2.41733112 0.37526317 999.25 -5.05221706e-01 6.05493469e-01 7.88588177e-01 2.26616179 0.36777664 999.50 -3.87740833e-01 4.36346597e-01 5.83730508e-01 2.29728142 0.20934426 999.75 -2.78852880e-01 2.31965614e-01 3.62721621e-01 2.44772651 0.08896538 1000.00 -2.44454265e-01 0.00000000e+00 2.44454265e-01 3.14159265 0.03251989