========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0049 Injection acquisition : SIG0050 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -8.62495664e-03 0.00000000e+00 8.62495664e-03 3.14159265 0.14305264 0.25 -7.76615801e-03 -5.88597760e-04 7.78843101e-03 -3.06594719 0.09628393 0.50 1.58403914e-02 -1.62798081e-02 2.27145361e-02 -0.79907769 0.13544343 0.75 4.38960209e-03 -1.02976068e-02 1.11941642e-02 -1.16784708 0.03403460 1.00 -2.73786439e-03 -6.19401400e-03 6.77212750e-03 -1.98699245 0.01592578 1.25 -3.55526926e-03 -1.84080744e-03 4.00356236e-03 -2.66383128 0.00786659 1.50 1.21574261e-04 1.53721176e-03 1.54201177e-03 1.49187309 0.00104865 1.75 -3.93867522e-04 -5.46183622e-03 5.47601922e-03 -1.64278437 0.01179000 2.00 -2.52436399e-03 -4.33342745e-03 5.01507797e-03 -2.09827334 0.00909188 2.25 -3.71213188e-03 -5.32837447e-04 3.75017851e-03 -2.99902698 0.00465372 2.50 -3.95939714e-03 4.24850209e-04 3.98212549e-03 3.03469990 0.00397969 2.75 2.47690825e-03 -3.02193714e-03 3.90732371e-03 -0.88419245 0.00413631 3.00 6.93617173e-03 -8.07284405e-04 6.98299265e-03 -0.11586630 0.01077611 3.25 1.44516804e-03 2.85543277e-03 3.20031357e-03 1.10227129 0.00264076 3.50 2.74592709e-03 6.78957403e-03 7.32382626e-03 1.18647434 0.01215030 3.75 1.27544417e-03 -2.66879568e-03 2.95790943e-03 -1.12497636 0.00182851 4.00 -3.29463836e-03 -3.32466537e-03 4.68060271e-03 -2.35165824 0.00379232 4.25 4.91858073e-04 7.26684926e-03 7.28347599e-03 1.50321422 0.00857849 4.50 4.56097957e-03 1.03197535e-02 1.12827234e-02 1.15464358 0.01951825 4.75 -3.13768834e-03 -3.57815911e-03 4.75902414e-03 -2.29070152 0.00340941 5.00 -2.22529711e-03 -4.73451527e-03 5.23140345e-03 -2.01017018 0.00377093 5.25 -3.04269427e-03 -6.84222205e-03 7.48825687e-03 -1.98922893 0.00797532 5.50 -3.19334415e-03 -2.10809048e-03 3.82642031e-03 -2.55811422 0.00198123 5.75 -6.10596211e-03 4.51692989e-03 7.59509242e-03 2.50467918 0.00704140 6.00 -7.37194007e-03 6.71913393e-03 9.97458075e-03 2.40248902 0.01121183 6.25 3.12755798e-03 -9.67025515e-04 3.27364586e-03 -0.29987115 0.00109539 6.50 -1.75785338e-03 -7.92478089e-03 8.11740110e-03 -1.78907936 0.00670022 6.75 -1.03739603e-02 -1.73019573e-02 2.01736655e-02 -2.11090919 0.03890632 7.00 -7.32018771e-03 -7.95203818e-03 1.08083329e-02 -2.31484555 0.01134870 7.25 -2.13679404e-03 -2.45909771e-03 3.25776769e-03 -2.28618047 0.00078062 7.50 9.12588512e-04 -7.16020529e-03 7.21812701e-03 -1.44402696 0.00441802 7.75 2.75199164e-03 -8.35823159e-03 8.79963029e-03 -1.25272053 0.00596488 8.00 -1.26809392e-03 1.01735263e-03 1.62575169e-03 2.46546962 0.00019606 8.25 -5.09222203e-04 1.17716289e-02 1.17826378e-02 1.61402781 0.00986427 8.50 -1.76951901e-03 3.84655344e-03 4.23404899e-03 2.00195747 0.00142305 8.75 -2.03240218e-03 -1.27533892e-02 1.29143175e-02 -1.72882919 0.01092587 9.00 -4.42218512e-03 -7.26456305e-03 8.50468092e-03 -2.11761301 0.00471775 9.25 -1.91795594e-02 1.51565154e-02 2.44453566e-02 2.47282939 0.03853920 9.50 -9.19213384e-03 4.79550770e-03 1.03678454e-02 2.66073857 0.00669473 9.75 -4.15716634e-04 4.54926126e-03 4.56821610e-03 1.66192436 0.00117482 10.00 -9.38180211e-03 -1.05867465e-03 9.44134539e-03 -3.02922457 0.00517912 10.25 -1.98911283e-02 4.53818720e-03 2.04022579e-02 2.91728077 0.02065985 10.50 -1.02975113e-02 1.23034651e-02 1.60441264e-02 2.26767127 0.01240760 10.75 1.36033672e-02 1.85010657e-02 2.29639072e-02 0.93678615 0.02117097 11.00 9.42749898e-03 5.75979541e-03 1.10477591e-02 0.54843710 0.00506594 11.25 -2.13954298e-03 -1.02781529e-03 2.37361505e-03 -2.69375567 0.00021112 11.50 -1.13600334e-03 -3.05900164e-03 3.26312651e-03 -1.92637554 0.00045673 11.75 -6.06745687e-03 5.01232791e-03 7.87003583e-03 2.45113827 0.00241883 12.00 -9.35081629e-03 -3.49838497e-03 9.98381002e-03 -2.78358831 0.00391709 12.25 -1.51616968e-02 -1.15123678e-02 1.90371128e-02 -2.49216224 0.01424748 12.50 -7.00141420e-03 5.72694548e-03 9.04531400e-03 2.45599015 0.00328852 12.75 3.17988314e-03 1.58251294e-02 1.61414491e-02 1.37249820 0.00997907 13.00 8.38185058e-03 5.79111132e-03 1.01878550e-02 0.60459977 0.00388428 13.25 2.00886085e-02 -3.09217548e-04 2.00909882e-02 -0.01539147 0.01233867 13.50 -5.90649782e-03 2.18966702e-03 6.29931410e-03 2.78657807 0.00119352 13.75 5.38752216e-03 -1.39236838e-03 5.56453814e-03 -0.25290927 0.00086077 14.00 1.28341727e-02 -4.40566917e-03 1.35693003e-02 -0.33067250 0.00471088 14.25 2.03017349e-02 -2.35051116e-03 2.04373516e-02 -0.11526563 0.01041153 14.50 3.42421451e-02 -4.92701356e-03 3.45947968e-02 -0.14290657 0.02999900 14.75 3.93185081e-02 9.14060963e-03 4.03670141e-02 0.22841872 0.03741887 15.00 3.88630882e-02 5.52013693e-03 3.92531723e-02 0.14109677 0.04166510 15.25 3.40414213e-02 1.60098667e-02 3.76182694e-02 0.43961106 0.03897451 15.50 3.83146253e-02 -7.56589627e-03 3.90544914e-02 -0.19495936 0.04334282 15.75 3.53043289e-02 -9.97794286e-03 3.66872591e-02 -0.27544269 0.03571818 16.00 -9.33125468e-04 -1.62985554e-02 1.63252452e-02 -1.62798593 0.00685903 16.25 6.65061625e-03 -1.67488416e-02 1.80209432e-02 -1.19281043 0.00764404 16.50 1.45287571e-02 1.19808835e-03 1.45780725e-02 0.08227708 0.00460969 16.75 3.46292993e-03 -6.68934915e-03 7.53254776e-03 -1.09310642 0.00106645 17.00 1.78806679e-02 -1.14749330e-02 2.12459966e-02 -0.57055426 0.01032496 17.25 1.89052766e-02 -6.89119230e-03 2.01220778e-02 -0.34954379 0.00908944 17.50 6.16936375e-02 -1.13614977e-02 6.27310811e-02 -0.18211940 0.06140616 17.75 4.53448015e-02 -5.17660861e-03 4.56393285e-02 -0.11366891 0.02996914 18.00 2.95960897e-02 -3.75692211e-02 4.78265083e-02 -0.90355429 0.02876420 18.25 2.68035115e-02 -2.28337870e-02 3.52109366e-02 -0.70559339 0.01770208 18.50 2.70382148e-02 4.02665976e-03 2.73364052e-02 0.14783821 0.01175043 18.75 4.52727322e-02 -9.79700383e-03 4.63206386e-02 -0.21311359 0.02802317 19.00 1.46250900e-01 -3.93711075e-02 1.51457618e-01 -0.26296837 0.24765884 19.25 1.06310619e-01 -3.03367691e-02 1.10554364e-01 -0.27797183 0.13125293 19.50 6.86029171e-02 -1.91657887e-02 7.12298230e-02 -0.27242700 0.05878255 19.75 5.37881119e-02 7.21042901e-03 5.42692479e-02 0.13325804 0.03685342 20.00 9.59970221e-02 -4.92658489e-03 9.61233556e-02 -0.05127520 0.09926949 20.25 4.38963496e-02 -2.02030673e-03 4.39428168e-02 -0.04599203 0.02254045 20.50 5.70348669e-02 4.24868434e-04 5.70364494e-02 0.00744914 0.04562744 20.75 4.54931540e-02 -2.55156628e-02 5.21601007e-02 -0.51114900 0.03692536 21.00 8.43043349e-02 -5.41117306e-02 1.00176346e-01 -0.57063286 0.11809026 21.25 8.60027015e-02 -4.44055182e-02 9.67900548e-02 -0.47662374 0.09838349 21.50 8.01408331e-02 -5.46282322e-02 9.69886430e-02 -0.59830606 0.08412374 21.75 9.94745740e-03 -3.69865962e-02 3.83009165e-02 -1.30806562 0.01762065 22.00 3.15255212e-03 -5.48892701e-02 5.49797286e-02 -1.51342460 0.03037835 22.25 1.69233550e-02 -1.10198156e-02 2.01949568e-02 -0.57719041 0.00547609 22.50 3.27849965e-02 -9.71824844e-03 3.41950340e-02 -0.28817252 0.01582105 22.75 1.00166464e-02 -1.29245854e-02 1.63517006e-02 -0.91148178 0.00350583 23.00 3.41825997e-02 -6.09692293e-03 3.47220765e-02 -0.17650720 0.01674990 23.25 5.56656595e-02 -6.71352223e-03 5.60690381e-02 -0.12002468 0.03171155 23.50 8.10198834e-02 -1.88997248e-02 8.31950786e-02 -0.22917440 0.06224471 23.75 8.69529674e-02 3.09547612e-04 8.69535183e-02 0.00355993 0.05969135 24.00 1.70271168e-01 1.70499132e-02 1.71122676e-01 0.09980121 0.17929701 24.25 1.95626908e-01 9.64268676e-03 1.95864414e-01 0.04925135 0.23390282 24.50 2.27967226e-01 9.89857437e-03 2.28182028e-01 0.04339378 0.30762304 24.75 1.92406427e-01 2.19575778e-02 1.93655282e-01 0.11362923 0.16687620 25.00 1.52878307e-01 -1.50165725e-02 1.53614043e-01 -0.09791157 0.12278040 25.25 1.74766987e-01 -8.24351282e-02 1.93233149e-01 -0.44074088 0.16666644 25.50 1.66747805e-01 -6.25214274e-02 1.78083574e-01 -0.35872335 0.15090628 25.75 1.12408387e-01 -2.88182585e-02 1.16043688e-01 -0.25096592 0.07155474 26.00 1.33694847e-01 -2.54956105e-02 1.36104145e-01 -0.18843749 0.09184427 26.25 1.43453189e-01 -7.49751205e-02 1.61864406e-01 -0.48159922 0.11074533 26.50 1.14228106e-01 -9.58058528e-02 1.49086624e-01 -0.69791123 0.10083035 26.75 8.73544430e-02 -8.56058668e-02 1.22307658e-01 -0.77528881 0.06612273 27.00 4.78045316e-02 -8.06649556e-02 9.37662429e-02 -1.03581303 0.04316969 27.25 -2.20175439e-02 -1.18310480e-01 1.20341771e-01 -1.75479118 0.07141136 27.50 2.03102845e-02 -1.01689728e-01 1.03698160e-01 -1.37366233 0.05280602 27.75 1.08974931e-01 5.77224419e-02 1.23318352e-01 0.48711302 0.07007779 28.00 7.68503318e-02 8.46760765e-03 7.73154181e-02 0.10974043 0.02779137 28.25 5.09876250e-02 -9.29594422e-02 1.06024506e-01 -1.06911068 0.04346907 28.50 1.47117702e-02 -8.36283117e-02 8.49124885e-02 -1.39665956 0.02787746 28.75 -3.47019512e-02 -4.19764215e-02 5.44632480e-02 -2.26160767 0.00970267 29.00 1.08064218e-02 -7.98874838e-02 8.06150658e-02 -1.43634193 0.02550625 29.25 3.69111810e-02 -9.80051457e-02 1.04725564e-01 -1.21060182 0.04479077 29.50 1.07071027e-03 -7.76916573e-02 7.76990350e-02 -1.55701566 0.02777433 29.75 -2.07681191e-02 -1.21733119e-01 1.23491971e-01 -1.73977316 0.05678835 30.00 -7.49339579e-02 -1.17657854e-01 1.39493615e-01 -2.13789313 0.07943898 30.25 -1.37171816e-01 -1.58374351e-01 2.09519789e-01 -2.28457701 0.19150790 30.50 -6.77459591e-02 -1.35418565e-01 1.51418964e-01 -2.03466058 0.11612737 30.75 -5.58672318e-02 -8.45328770e-02 1.01325983e-01 -2.15479149 0.06300647 31.00 -3.17658982e-02 -5.45021845e-02 6.30837571e-02 -2.09850049 0.02382482 31.25 -2.81607228e-02 -8.64032569e-02 9.08765597e-02 -1.88586192 0.04370765 31.50 -7.40482384e-02 -4.97853619e-02 8.92284925e-02 -2.54967478 0.03296066 31.75 -1.33986282e-01 -6.40646329e-02 1.48514649e-01 -2.69558286 0.07963029 32.00 -2.11154249e-01 -9.95887514e-02 2.33460995e-01 -2.70088949 0.26608955 32.25 -2.82316198e-01 -8.80804797e-02 2.95737395e-01 -2.83917038 0.38921790 32.50 -1.59610606e-01 -2.78157525e-02 1.62016239e-01 -2.96905288 0.18357979 32.75 -9.77165913e-02 -7.81163784e-03 9.80283321e-02 -3.06182052 0.07884038 33.00 -9.30400553e-02 -3.86257804e-02 1.00739281e-01 -2.74809269 0.04744458 33.25 -1.01645710e-01 -5.46202436e-02 1.15391600e-01 -2.64850635 0.04327763 33.50 -2.21507555e-01 -1.00177232e-01 2.43107126e-01 -2.71686755 0.29390315 33.75 -1.97156401e-01 -1.11877717e-01 2.26687605e-01 -2.62544586 0.35688717 34.00 -1.37771239e-01 -7.81797801e-02 1.58407678e-01 -2.62544273 0.11287921 34.25 -6.60761855e-02 -7.67012264e-02 1.01238038e-01 -2.28191459 0.03641752 34.50 -3.77262342e-02 -7.34628893e-02 8.25836839e-02 -2.04521827 0.02349594 34.75 -9.07673178e-02 -1.05801909e-01 1.39401398e-01 -2.27985815 0.05693730 35.00 -1.43007090e-01 -6.18573975e-02 1.55811955e-01 -2.73334639 0.05262934 35.25 -1.67137547e-01 -1.12613762e-01 2.01536148e-01 -2.54868231 0.06743544 35.50 -1.83216254e-01 -4.27663362e-02 1.88141317e-01 -2.91227854 0.08418778 35.75 -1.43304386e-01 5.05199906e-02 1.51948730e-01 2.80266016 0.06378474 36.00 5.09735447e-02 2.39072705e-01 2.44446437e-01 1.36072829 0.16070861 36.25 2.99403340e-01 4.46215795e-01 5.37355465e-01 0.97981125 0.62883668 36.50 3.98635784e-01 5.04552146e-01 6.43026715e-01 0.90213445 0.78583036 36.75 3.68611555e-01 3.83379729e-01 5.31840667e-01 0.80503440 0.54844074 37.00 6.37758753e-02 -1.67591419e-02 6.59411185e-02 -0.25697198 0.00831153 37.25 -6.03912473e-02 -9.87483975e-02 1.15751237e-01 -2.11967749 0.02226767 37.50 -2.80917245e-02 1.07271911e-01 1.10889169e-01 1.82691892 0.01102084 37.75 2.10388124e-02 1.59910517e-01 1.61288577e-01 1.43998150 0.02468499 38.00 6.61704389e-02 1.38344450e-01 1.53354862e-01 1.12465723 0.02426082 38.25 9.88353687e-02 1.07458312e-01 1.45999037e-01 0.82717320 0.02277163 38.50 1.87436871e-01 1.10396989e-01 2.17531781e-01 0.53227882 0.03568441 38.75 1.28802035e-01 2.84507538e-01 3.12305145e-01 1.14568339 0.07414640 39.00 -1.11554367e-03 3.79267801e-01 3.79269441e-01 1.57373763 0.09471078 39.25 7.63057329e-02 3.36787127e-01 3.45323231e-01 1.34798840 0.06742987 39.50 -4.77830971e-02 2.17766327e-01 2.22947073e-01 1.78679689 0.01574326 39.75 2.31741907e-01 5.01394758e-01 5.52359497e-01 1.13784784 0.09129432 40.00 1.13223867e+00 9.21142633e-01 1.45961233e+00 0.68295394 0.33890176 40.25 7.04530828e-01 5.19295324e-01 8.75232153e-01 0.63518066 0.16673950 40.50 8.59522095e-01 4.56172270e-01 9.73073158e-01 0.48792660 0.15233942 40.75 9.81859291e-01 3.73069175e-01 1.05034674e+00 0.36311376 0.15295391 41.00 1.31548571e+00 2.76272779e-01 1.34418351e+00 0.20700732 0.17244953 41.25 8.88215204e-01 6.81060930e-02 8.90822479e-01 0.07652772 0.08122329 41.50 7.11444399e-01 -2.73681743e-01 7.62269525e-01 -0.36723418 0.04481340 41.75 8.39448258e-01 -1.03185138e-01 8.45766250e-01 -0.12230666 0.04737697 42.00 1.13657724e+00 1.31363587e-01 1.14414344e+00 0.11506767 0.07013968 42.25 7.94165507e-01 -7.00688126e-01 1.05908579e+00 -0.72294668 0.05799693 42.50 5.63053552e-01 -5.43396470e-01 7.82501774e-01 -0.76763413 0.01337036 42.75 -2.88745993e-01 -6.20627967e-01 6.84509549e-01 -2.00625799 0.00375161 43.00 -1.76095324e+00 -1.16303257e+00 2.11035567e+00 -2.55790190 0.01812443 43.25 -1.51600705e+00 -1.43475009e-01 1.52278116e+00 -3.04723363 0.01601834 43.50 7.80521589e-01 1.07033861e+00 1.32470325e+00 0.94072195 0.01157284 43.75 -3.71074209e-01 -1.77494922e-01 4.11339904e-01 -2.69543305 0.00046315 44.00 -4.90995141e+00 -1.90807638e+00 5.26767295e+00 -2.77094007 0.03346267 44.25 -4.14736340e+00 -6.57045325e-01 4.19908701e+00 -2.98447362 0.03733753 44.50 -1.76082314e+00 -2.17132192e+00 2.79555665e+00 -2.25217564 0.02641115 44.75 -3.65632586e-01 -1.57835164e-01 3.98245059e-01 -2.73408018 0.00178128 45.00 -5.92569490e-01 4.63125153e-01 7.52079456e-01 2.47820081 0.01090871 45.25 -8.37105882e-01 4.09468272e-01 9.31885467e-01 2.68666465 0.03849752 45.50 -7.28349838e-01 5.51582588e-01 9.13639337e-01 2.49343305 0.05399952 45.75 -8.02227747e-01 -2.17933852e-01 8.31302906e-01 -2.87633349 0.05500282 46.00 -8.36512508e-01 -4.32333453e-01 9.41629115e-01 -2.66457311 0.07368073 46.25 -2.90824906e-01 2.69930977e-01 3.96789438e-01 2.39343755 0.01303429 46.50 -1.09449006e-01 2.49069448e-01 2.72056382e-01 1.98482696 0.00694768 46.75 1.20605841e-01 2.44490069e-01 2.72619080e-01 1.11252672 0.01455757 47.00 -1.83496991e-02 4.49129008e-01 4.49503701e-01 1.61162980 0.04122136 47.25 -7.48663852e-02 1.62402801e-01 1.78828536e-01 2.00275348 0.00706549 47.50 4.98575730e-02 1.20669173e-01 1.30563497e-01 1.17898342 0.00357533 47.75 1.41566135e-01 -9.02505894e-02 1.67887282e-01 -0.56754856 0.00483990 48.00 -9.65909252e-02 -3.84503957e-02 1.03962684e-01 -2.76274719 0.00172204 48.25 3.12190214e-02 6.33080761e-02 7.05871079e-02 1.11266095 0.00068408 48.50 6.32537713e-02 -1.77217697e-01 1.88167882e-01 -1.22796389 0.00454650 48.75 -2.62744208e-01 -2.14493242e-01 3.39178227e-01 -2.45695682 0.01280424 49.00 -2.73376071e-01 -2.54713993e-01 3.73649159e-01 -2.39151861 0.01092062 49.25 -2.84696159e-01 -5.64971144e-01 6.32648636e-01 -2.03756923 0.01805418 49.50 -3.28454506e-01 -1.17502296e+00 1.22006611e+00 -1.84336941 0.02571470 49.75 -2.48591559e-01 -4.50021295e+00 4.50707381e+00 -1.62598020 0.04441187 50.00 -6.97789247e-01 -4.76272931e+00 4.81357459e+00 -1.71627170 0.03063189 50.25 1.97659759e-01 5.89891382e-01 6.22126372e-01 1.24747619 0.00122482 50.50 4.46241259e-01 1.45535093e+00 1.52222784e+00 1.27327628 0.04038007 50.75 1.38384592e-01 6.10474773e-01 6.25963053e-01 1.34788003 0.02175740 51.00 1.77989446e-01 4.96313313e-01 5.27263831e-01 1.22646016 0.02434222 51.25 -8.62593222e-02 5.85593602e-01 5.91912610e-01 1.71704696 0.04058931 51.50 -1.79168049e-02 3.97826524e-01 3.98229777e-01 1.61580264 0.02469469 51.75 8.03614686e-03 1.24940485e-01 1.25198660e-01 1.50656501 0.00316223 52.00 4.26507043e-02 2.14912390e-01 2.19103669e-01 1.37488559 0.01227547 52.25 -2.08050159e-03 3.12178128e-01 3.12185060e-01 1.57746070 0.02957547 52.50 5.73514334e-02 3.50126172e-01 3.54792225e-01 1.40843600 0.03677361 52.75 1.44287059e-01 4.78213860e-01 4.99507008e-01 1.27776158 0.07632890 53.00 -2.42802885e-02 4.20882292e-01 4.21582063e-01 1.62842148 0.06648664 53.25 -5.26765150e-02 5.45306821e-01 5.47845182e-01 1.66709730 0.14265033 53.50 -8.98909516e-02 8.94102926e-01 8.98610275e-01 1.67099722 0.20406773 53.75 -1.05867878e-01 1.19405387e+00 1.19873794e+00 1.65922765 0.22854422 54.00 -6.55379277e-02 9.08831256e-01 9.11191238e-01 1.64278403 0.14601939 54.25 6.49625740e-02 3.11416715e-01 3.18120270e-01 1.36514215 0.01890066 54.50 -3.53673787e-01 -4.69254073e-01 5.87609167e-01 -2.21665714 0.01464553 54.75 -1.53094040e+00 -1.48950577e+00 2.13597892e+00 -2.36991168 0.09609873 55.00 -1.22542720e+00 5.92257478e-01 1.36104399e+00 2.69138845 0.04346499 55.25 -2.29252958e-01 1.44910598e+00 1.46712817e+00 1.72769898 0.06625643 55.50 9.96849398e-02 2.94573823e-01 3.10983640e-01 1.24448920 0.00674208 55.75 1.40834915e-01 6.99641210e-02 1.57256006e-01 0.46106916 0.00196401 56.00 1.14827355e+00 3.39129762e-01 1.19730578e+00 0.28717502 0.10597375 56.25 1.44652892e+00 5.86262822e-01 1.56081710e+00 0.38505786 0.15241286 56.50 1.23163692e+00 1.06178819e-01 1.23620526e+00 0.08599689 0.11195244 56.75 1.28926477e+00 -1.53587476e-01 1.29838082e+00 -0.11856917 0.10424099 57.00 3.10685998e+00 -2.06009104e-01 3.11368250e+00 -0.06621089 0.28141434 57.25 4.36719308e+00 -5.72622553e-01 4.40457398e+00 -0.13037538 0.38343969 57.50 7.86413664e+00 -2.54270609e+00 8.26498635e+00 -0.31272010 0.56860519 57.75 9.55704111e+00 -4.79873763e+00 1.06941534e+01 -0.46533851 0.59689240 58.00 5.89643101e+00 -1.07235735e+01 1.22377665e+01 -1.06806298 0.55037883 58.25 1.93868188e+00 -1.00297096e+01 1.02153591e+01 -1.37985716 0.43631299 58.50 -4.64959189e+00 -3.83016753e+00 6.02402590e+00 -2.45252835 0.28480344 58.75 -5.81375705e+00 -2.78099411e+00 6.44466440e+00 -2.69541689 0.50033132 59.00 -6.63815981e+00 -1.07187257e+00 6.72414131e+00 -2.98150311 0.68038729 59.25 -5.50342041e+00 -1.20367050e+00 5.63351212e+00 -2.92627011 0.58487127 59.50 -5.08590301e+00 -7.19047766e-01 5.13648120e+00 -3.00114296 0.60414916 59.75 -5.10085454e+00 1.61989341e-01 5.10342607e+00 3.10984603 0.61882256 60.00 -6.29316135e+00 6.45930801e-01 6.32622370e+00 3.03931072 0.71539392 60.25 -5.42989916e+00 7.24239267e-01 5.47798571e+00 3.00899539 0.67687543 60.50 -4.77599917e+00 1.13335600e+00 4.90863157e+00 2.90859992 0.64107764 60.75 -4.14871758e+00 1.54280122e+00 4.42629565e+00 2.78556518 0.53672648 61.00 -4.59593555e+00 1.36968989e+00 4.79569328e+00 2.85195153 0.57710685 61.25 -4.06104560e+00 1.18094513e+00 4.22926977e+00 2.85859902 0.53027903 61.50 -3.99420514e+00 1.40838108e+00 4.23523458e+00 2.80259804 0.60068972 61.75 -4.09337430e+00 1.67820393e+00 4.42403454e+00 2.75251206 0.53001359 62.00 -5.31915030e+00 2.63052344e+00 5.93405540e+00 2.68232396 0.64121368 62.25 -4.87874518e+00 3.18168598e+00 5.82454120e+00 2.56370572 0.56800045 62.50 -4.94957316e+00 3.82702224e+00 6.25654647e+00 2.48340657 0.58648648 62.75 -5.74355602e+00 4.07761433e+00 7.04381817e+00 2.52422270 0.63158615 63.00 -6.39145043e+00 5.55904277e+00 8.47074938e+00 2.42573684 0.75338764 63.25 -5.46086797e+00 7.39620699e+00 9.19374553e+00 2.20678902 0.61868433 63.50 -5.56061957e+00 1.03557300e+01 1.17542177e+01 2.06357344 0.64393944 63.75 -4.12487496e+00 1.37780438e+01 1.43822489e+01 1.86168450 0.62346735 64.00 -2.82010813e+00 1.72575230e+01 1.74864265e+01 1.73277787 0.59987870 64.25 7.84348425e+00 1.81710962e+01 1.97916392e+01 1.16330980 0.58408368 64.50 1.45568598e+01 1.75150496e+01 2.27745281e+01 0.87737409 0.70439952 64.75 1.25897002e+01 8.66953939e+00 1.52859892e+01 0.60304856 0.61781589 65.00 1.26368140e+01 3.86281259e+00 1.32140225e+01 0.29665899 0.68411311 65.25 9.95403545e+00 2.21618695e-01 9.95650223e+00 0.02226053 0.65354760 65.50 8.77774066e+00 -9.43973515e-01 8.82835302e+00 -0.10713001 0.66220517 65.75 6.70985634e+00 -1.59766926e+00 6.89744294e+00 -0.23375509 0.61159974 66.00 5.94634604e+00 -1.59833057e+00 6.15740951e+00 -0.26258562 0.59586603 66.25 4.06166575e+00 -2.12878398e+00 4.58572240e+00 -0.48275375 0.51145104 66.50 3.05417605e+00 -2.04508355e+00 3.67564390e+00 -0.59003227 0.44890410 66.75 2.49593923e+00 -1.97854156e+00 3.18501795e+00 -0.67027644 0.57914103 67.00 2.43499167e+00 -2.04728264e+00 3.18128129e+00 -0.69911464 0.65063309 67.25 1.92122739e+00 -1.76634329e+00 2.60980523e+00 -0.74342117 0.61984926 67.50 1.73066168e+00 -1.48490565e+00 2.28038037e+00 -0.70911949 0.55599866 67.75 1.38437853e+00 -1.25505725e+00 1.86860178e+00 -0.73644151 0.50404833 68.00 1.12274994e+00 -1.16411179e+00 1.61731991e+00 -0.80348292 0.48533794 68.25 1.05405252e+00 -5.10236422e-01 1.17105419e+00 -0.45082352 0.36393818 68.50 8.76603932e-01 -2.47569830e-01 9.10892570e-01 -0.27525067 0.29685207 68.75 1.15063402e+00 -1.47082656e-01 1.15999654e+00 -0.12713801 0.49378384 69.00 1.19517265e+00 -9.73709026e-02 1.19913250e+00 -0.08129062 0.56597363 69.25 1.29183051e+00 -1.35058581e-01 1.29887139e+00 -0.10416978 0.65342208 69.50 1.31571976e+00 -1.21474910e-01 1.32131550e+00 -0.09206483 0.63234228 69.75 1.24929461e+00 -1.58710063e-01 1.25933551e+00 -0.12636285 0.65745649 70.00 1.28205334e+00 2.19366324e-02 1.28224100e+00 0.01710888 0.66813111 70.25 1.37296168e+00 8.93559342e-02 1.37586637e+00 0.06499095 0.77143075 70.50 1.30763679e+00 5.66518144e-02 1.30886340e+00 0.04329674 0.72308454 70.75 1.36908631e+00 5.90802559e-02 1.37036046e+00 0.04312630 0.82781399 71.00 1.26992609e+00 7.21333758e-02 1.27197307e+00 0.05674027 0.74303708 71.25 1.25851522e+00 2.33069789e-01 1.27991488e+00 0.18311959 0.75047945 71.50 1.28190431e+00 1.83909349e-01 1.29502947e+00 0.14249343 0.69983447 71.75 1.50439805e+00 9.91662051e-02 1.50766290e+00 0.06582231 0.81731151 72.00 1.42643402e+00 1.54310663e-01 1.43475636e+00 0.10776026 0.77300095 72.25 1.38106434e+00 2.71686701e-01 1.40753415e+00 0.19424233 0.80828335 72.50 1.36263598e+00 1.98841620e-01 1.37706747e+00 0.14490151 0.81440163 72.75 1.41759376e+00 8.30363429e-02 1.42002363e+00 0.05850870 0.88683351 73.00 1.38829027e+00 2.25229434e-02 1.38847296e+00 0.01622209 0.84133024 73.25 1.42660950e+00 -3.19105445e-02 1.42696634e+00 -0.02236437 0.87432592 73.50 1.39964314e+00 2.75851864e-02 1.39991495e+00 0.01970618 0.86983536 73.75 1.45454824e+00 8.63965989e-03 1.45457389e+00 0.00593968 0.91280653 74.00 1.36909827e+00 -3.63999155e-02 1.36958207e+00 -0.02658052 0.87374819 74.25 1.39190860e+00 -4.08612599e-03 1.39191460e+00 -0.00293562 0.90581473 74.50 1.36464383e+00 -5.21751408e-02 1.36564088e+00 -0.03821491 0.85779495 74.75 1.41387353e+00 -6.92954319e-02 1.41557063e+00 -0.04897187 0.88595204 75.00 1.31531404e+00 -6.01825520e-03 1.31532781e+00 -0.00457550 0.80933527 75.25 1.32883237e+00 6.52250424e-02 1.33043218e+00 0.04904511 0.81803462 75.50 1.25938485e+00 7.85852225e-02 1.26183431e+00 0.06231889 0.80301563 75.75 1.31711095e+00 9.02267654e-02 1.32019776e+00 0.06839669 0.85293907 76.00 1.29071616e+00 7.94614542e-02 1.29315982e+00 0.06148625 0.80196615 76.25 1.31259683e+00 6.60708486e-02 1.31425865e+00 0.05029353 0.84018491 76.50 1.34402900e+00 5.57619626e-03 1.34404057e+00 0.00414884 0.82542089 76.75 1.39023199e+00 1.42257681e-02 1.39030477e+00 0.01023230 0.84355940 77.00 1.44447829e+00 1.82911565e-01 1.45601310e+00 0.12595774 0.81915390 77.25 1.43264100e+00 1.22582200e-01 1.43787574e+00 0.08535590 0.78471761 77.50 1.47159026e+00 7.98294059e-02 1.47375393e+00 0.05419392 0.76472689 77.75 1.52815847e+00 2.99423885e-02 1.52845178e+00 0.01959127 0.78471770 78.00 1.65892706e+00 7.36080700e-02 1.66055928e+00 0.04434181 0.78642856 78.25 1.62845992e+00 2.95840999e-02 1.62872862e+00 0.01816492 0.72589487 78.50 1.25786819e+00 2.13947396e-01 1.27593334e+00 0.16847500 0.49612545 78.75 1.31421081e+00 2.71983603e-01 1.34206003e+00 0.20407483 0.50987339 79.00 1.47979568e+00 4.45859271e-01 1.54550501e+00 0.29264707 0.54004113 79.25 1.55178635e+00 4.49893207e-01 1.61568709e+00 0.28218322 0.49266658 79.50 1.71179155e+00 7.65536132e-01 1.87517356e+00 0.42053418 0.44268657 79.75 2.16126065e+00 1.03633619e+00 2.39688137e+00 0.44711793 0.44315716 80.00 3.36886021e+00 2.08502820e+00 3.96188865e+00 0.55420949 0.46765665 80.25 5.52371947e+00 1.75275702e+00 5.79513882e+00 0.30726512 0.43385221 80.50 1.01812053e+01 -1.70996076e+00 1.03238029e+01 -0.16639968 0.48455630 80.75 7.08878821e+00 -6.88523419e+00 9.88217426e+00 -0.77083259 0.35631681 81.00 -8.17256203e-01 -9.24216365e+00 9.27822702e+00 -1.65899386 0.50610156 81.25 -2.36555203e+00 -6.90139482e+00 7.29555254e+00 -1.90101064 0.47015405 81.50 -5.10549731e+00 -5.69449748e+00 7.64809809e+00 -2.30171138 0.65859994 81.75 -4.03052553e+00 -3.45075887e+00 5.30592809e+00 -2.43353552 0.64405773 82.00 -3.57093691e+00 -3.02363626e+00 4.67909892e+00 -2.43899731 0.80420605 82.25 -3.49134724e+00 -2.72408544e+00 4.42833456e+00 -2.47901775 0.70469644 82.50 -3.51326016e+00 -1.46086168e+00 3.80488026e+00 -2.74752855 0.61501262 82.75 -3.73706849e+00 -7.38091940e-01 3.80925985e+00 -2.94659671 0.64100228 83.00 -3.56871137e+00 -4.78483476e-01 3.60064539e+00 -3.00831014 0.60765085 83.25 -3.59517256e+00 4.84592734e-01 3.62768465e+00 3.00761033 0.38936191 83.50 -3.34941347e+00 3.83953770e+00 5.09515655e+00 2.28812240 0.39029402 83.75 4.56617435e-01 4.73368922e+00 4.75566117e+00 1.47463263 0.39384927 84.00 3.10909832e+00 2.55372208e+00 4.02342998e+00 0.68763666 0.49189848 84.25 2.43721938e+00 1.56335207e+00 2.89553243e+00 0.57034051 0.48413751 84.50 1.78754672e+00 5.94909790e-01 1.88394292e+00 0.32127765 0.39785552 84.75 1.93862288e+00 3.86597032e-01 1.97679436e+00 0.19683625 0.48508530 85.00 2.08063872e+00 3.54136926e-01 2.11056164e+00 0.16859024 0.56762713 85.25 1.56873431e+00 -1.50763364e-01 1.57596222e+00 -0.09581085 0.44843026 85.50 1.60556716e+00 -2.33111233e-01 1.62240154e+00 -0.14418186 0.47304867 85.75 1.37946290e+00 -1.86666551e-01 1.39203531e+00 -0.13450130 0.34057594 86.00 1.63263054e+00 -4.01632553e-01 1.68130639e+00 -0.24121357 0.43072201 86.25 1.48236966e+00 -6.15175099e-01 1.60494866e+00 -0.39336538 0.37814434 86.50 1.47034969e+00 -5.90116691e-01 1.58435032e+00 -0.38166485 0.37382284 86.75 1.07267492e+00 -6.43676097e-01 1.25097978e+00 -0.54046827 0.21521655 87.00 1.06959497e+00 -6.07247942e-01 1.22995263e+00 -0.51635832 0.20129426 87.25 8.70725403e-01 -2.88352156e-01 9.17229357e-01 -0.31979611 0.15798784 87.50 8.68978401e-01 -3.26646453e-01 9.28343345e-01 -0.35955693 0.16388113 87.75 8.14247023e-01 -4.31604435e-01 9.21564215e-01 -0.48740989 0.16366565 88.00 4.46285768e-01 -5.45004538e-01 7.04415313e-01 -0.88465703 0.09324222 88.25 3.86287787e-01 -4.70686117e-01 6.08903666e-01 -0.88356573 0.05749511 88.50 -2.17792660e-01 -7.34025835e-01 7.65654993e-01 -1.85923186 0.10044183 88.75 -3.64801637e-01 -5.19727208e-01 6.34977642e-01 -2.18280291 0.31506843 89.00 -1.12410545e-01 -4.57619114e-01 4.71223285e-01 -1.81166930 0.24007157 89.25 5.35427056e-01 -7.19766914e-01 8.97076665e-01 -0.93121742 0.36803162 89.50 6.45383081e-01 -8.61249334e-01 1.07622941e+00 -0.92770697 0.39324305 89.75 5.38311165e-01 -7.35527414e-01 9.11471057e-01 -0.93899911 0.27046064 90.00 2.89073542e-01 -7.14101847e-01 7.70392731e-01 -1.18615273 0.18019096 90.25 5.27208333e-02 -7.90120923e-01 7.91877868e-01 -1.50417007 0.14460429 90.50 -9.32368934e-02 -8.06131398e-01 8.11505360e-01 -1.68594437 0.14153535 90.75 -2.23970111e-01 -1.03349803e+00 1.05748796e+00 -1.78420706 0.20220282 91.00 -2.40044216e-01 -8.02670279e-01 8.37795203e-01 -1.86138782 0.14823218 91.25 -4.03152943e-01 -8.47047514e-01 9.38094765e-01 -2.01502015 0.22852463 91.50 -7.31913590e-02 -6.74391881e-01 6.78351962e-01 -1.67890262 0.12917628 91.75 -2.27823248e-01 -8.66969382e-01 8.96403560e-01 -1.82776770 0.13676135 92.00 -5.11683216e-01 -6.28084207e-01 8.10129301e-01 -2.25442038 0.08332477 92.25 -9.82814697e-01 -5.18776436e-01 1.11132971e+00 -2.65591591 0.20679601 92.50 -6.20375468e-01 -3.49240020e-01 7.11922968e-01 -2.62886185 0.12539640 92.75 -5.71679278e-01 -3.36738047e-01 6.63483013e-01 -2.60927604 0.15793091 93.00 -8.15113724e-01 -1.29541186e-01 8.25343141e-01 -2.98398665 0.26462100 93.25 -9.53450401e-01 -2.90035221e-01 9.96588228e-01 -2.84629133 0.48737536 93.50 -8.78691172e-01 -2.60921846e-01 9.16612451e-01 -2.85294212 0.46999965 93.75 -9.26172513e-01 -3.08112126e-01 9.76078176e-01 -2.82043697 0.54034877 94.00 -7.31767386e-01 -3.00350043e-01 7.91007999e-01 -2.75211478 0.38528682 94.25 -9.05469666e-01 -1.24571214e-01 9.13998525e-01 -3.00487456 0.45804027 94.50 -7.78665879e-01 -1.25441783e-01 7.88705390e-01 -2.98186665 0.38549274 94.75 -6.14547922e-01 -1.28359304e-01 6.27809891e-01 -2.93568504 0.34305124 95.00 -5.66288988e-01 2.73631203e-02 5.66949696e-01 3.09331014 0.23774586 95.25 -5.37277470e-01 1.16330121e-01 5.49727002e-01 2.92836623 0.29437443 95.50 -3.63205336e-01 2.41712264e-01 4.36283090e-01 2.55439987 0.24177713 95.75 -3.20534919e-01 2.71212744e-01 4.19879729e-01 2.43935229 0.32873578 96.00 -2.54209673e-01 1.32449889e-01 2.86645305e-01 2.66126596 0.24039774 96.25 -2.35095742e-01 1.24646357e-01 2.66095326e-01 2.65408261 0.30061944 96.50 -2.87907683e-01 -2.52999858e-02 2.89017167e-01 -3.05394246 0.33464430 96.75 -2.86018208e-01 -3.97273724e-02 2.88764055e-01 -3.00357764 0.40539122 97.00 -2.90209318e-01 -4.67093719e-02 2.93944236e-01 -2.98201063 0.42472586 97.25 -2.85038319e-01 -3.78820936e-02 2.87544599e-01 -3.00946518 0.36469180 97.50 -1.54441217e-01 -8.76744268e-02 1.77591933e-01 -2.62527089 0.12098980 97.75 -1.10458486e-01 -1.89074845e-01 2.18975739e-01 -2.09952095 0.17003544 98.00 -8.62338371e-02 -2.15360264e-01 2.31983444e-01 -1.95166184 0.14859985 98.25 -7.76827154e-02 -2.09786086e-01 2.23706965e-01 -1.92543560 0.11087645 98.50 -1.30986411e-01 -3.13960727e-01 3.40189326e-01 -1.96604721 0.15916696 98.75 -2.67028477e-01 -4.33937411e-01 5.09515342e-01 -2.12243471 0.22822189 99.00 -5.72737443e-01 -1.54593540e-01 5.93234643e-01 -2.87795498 0.20229943 99.25 -5.16402331e-01 1.47832146e-02 5.16613890e-01 3.11297315 0.15614130 99.50 -3.23832752e-01 -1.64999600e-01 3.63445346e-01 -2.67035726 0.06721622 99.75 1.47852503e-01 -2.73784299e-01 3.11156239e-01 -1.07563766 0.00695369 100.00 1.13964480e+00 -2.05815435e+00 2.35261336e+00 -1.06510023 0.09219378 100.25 6.31499530e-01 -7.94136844e-01 1.01461568e+00 -0.89898760 0.03367489 100.50 -1.44318607e-01 -5.76689816e-02 1.55414194e-01 -2.76143553 0.02042585 100.75 -2.10683963e-01 -7.81911806e-02 2.24725594e-01 -2.78621900 0.07822532 101.00 -2.24927618e-01 -4.56791249e-03 2.24973997e-01 -3.12128708 0.11951638 101.25 -2.34243068e-01 4.80268035e-02 2.39115848e-01 2.93936548 0.13657616 101.50 -1.33530376e-01 1.24032132e-01 1.82247993e-01 2.39305522 0.15634609 101.75 -8.80318471e-02 8.67890279e-02 1.23620150e-01 2.36330347 0.08480987 102.00 -8.37358926e-02 2.45335653e-03 8.37718250e-02 3.11230229 0.05695337 102.25 -1.17176630e-01 -2.06064411e-02 1.18974737e-01 -2.96751466 0.10563844 102.50 -2.33947640e-01 5.44475361e-02 2.40199984e-01 2.91292932 0.38049549 102.75 -1.69125665e-01 9.96544796e-02 1.96302078e-01 2.60912744 0.23561243 103.00 -4.88485880e-02 1.54826795e-01 1.62349995e-01 1.87641626 0.21533033 103.25 -3.52954173e-03 9.15791923e-02 9.16471829e-02 1.60931813 0.08026873 103.50 -1.93191381e-02 3.58849179e-02 4.07548332e-02 2.06466187 0.02718633 103.75 -7.53579953e-02 3.18190001e-02 8.18002214e-02 2.74206387 0.09919144 104.00 -1.25875000e-01 4.02765714e-02 1.32161711e-01 2.83191442 0.25693920 104.25 -2.35496075e-01 7.13751421e-02 2.46074810e-01 2.84730871 0.43089631 104.50 -3.19214210e-01 1.21253075e-01 3.41467451e-01 2.77857794 0.67515659 104.75 -3.57164035e-01 1.83674306e-01 4.01624699e-01 2.66660416 0.55124552 105.00 -4.59284267e-01 2.90380001e-01 5.43380698e-01 2.57780069 0.58027160 105.25 -5.67608964e-01 4.60848362e-01 7.31136888e-01 2.45963056 0.58971543 105.50 -6.95865957e-01 5.95869059e-01 9.16127374e-01 2.43345326 0.61763822 105.75 -1.03700356e+00 8.73317962e-01 1.35575095e+00 2.44167055 0.55429916 106.00 -1.18360565e+00 1.69845810e+00 2.07018894e+00 2.17941899 0.58429346 106.25 1.10943049e+00 2.96203618e+00 3.16298820e+00 1.21242028 0.56951013 106.50 2.09192657e+00 2.21362577e+00 3.04570121e+00 0.81365628 0.64149931 106.75 1.48762748e+00 6.08626300e-01 1.60731499e+00 0.38834833 0.71566086 107.00 1.28293362e+00 2.38633735e-01 1.30493859e+00 0.18390459 0.87817638 107.25 9.64168972e-01 1.17853609e-01 9.71345088e-01 0.12162999 0.82139511 107.50 8.39149868e-01 9.18473827e-02 8.44161384e-01 0.10901893 0.85769048 107.75 7.24376434e-01 5.94117273e-02 7.26808759e-01 0.08183458 0.80601393 108.00 6.63651083e-01 1.50295419e-02 6.63821247e-01 0.02264288 0.83636056 108.25 5.04587062e-01 5.71764234e-02 5.07816155e-01 0.11283202 0.74540994 108.50 4.72390226e-01 7.42883083e-02 4.78195858e-01 0.15598298 0.79794229 108.75 4.30375729e-01 7.07919279e-02 4.36159106e-01 0.16302879 0.65878924 109.00 3.49461659e-01 8.98797228e-02 3.60834887e-01 0.25173870 0.50605508 109.25 1.83889378e-01 1.71723606e-01 2.51603458e-01 0.75120079 0.25356884 109.50 1.76926081e-01 2.12678706e-01 2.76649725e-01 0.87690826 0.23613383 109.75 3.12989741e-01 3.38090598e-01 4.60725331e-01 0.82393171 0.34299942 110.00 2.81272620e-01 3.19865244e-01 4.25943730e-01 0.84950947 0.36227435 110.25 9.99800542e-02 3.66546409e-01 3.79937207e-01 1.30451164 0.34755961 110.50 -2.75517775e-02 3.88561470e-01 3.89537054e-01 1.64158497 0.27247125 110.75 -2.67595352e-01 3.79666514e-01 4.64493202e-01 2.18474776 0.23020587 111.00 -4.30105034e-01 5.30779259e-01 6.83166862e-01 2.25180288 0.29515487 111.25 -8.51558707e-01 4.73995245e-01 9.74589003e-01 2.63368055 0.27201255 111.50 -1.14584524e+00 9.84228293e-01 1.51051867e+00 2.43192327 0.33532040 111.75 -8.72965482e-01 2.74891086e+00 2.88419480e+00 1.87829141 0.39302726 112.00 3.17611702e-01 3.82265890e+00 3.83583084e+00 1.48790014 0.42718725 112.25 2.60602817e+00 3.66667327e+00 4.49843036e+00 0.95290282 0.61706610 112.50 2.92582319e+00 2.12910168e+00 3.61849627e+00 0.62907125 0.59239610 112.75 1.97921072e+00 6.24235964e-01 2.07531820e+00 0.30552141 0.61175079 113.00 1.68601868e+00 3.39982500e-01 1.71995555e+00 0.19897979 0.68857870 113.25 1.61406973e+00 1.67125336e-01 1.62269898e+00 0.10317515 0.82549449 113.50 1.45853630e+00 9.45740697e-02 1.46159926e+00 0.06475112 0.82883772 113.75 1.37484722e+00 5.84529060e-02 1.37608925e+00 0.04249034 0.87654439 114.00 1.23897875e+00 -4.20165307e-02 1.23969098e+00 -0.03389924 0.80131167 114.25 1.21515782e+00 -1.52228928e-01 1.22465594e+00 -0.12462578 0.84340161 114.50 1.21979503e+00 -1.55341936e-01 1.22964671e+00 -0.12666901 0.76957333 114.75 1.16464889e+00 -2.93343770e-01 1.20102357e+00 -0.24674084 0.75310379 115.00 1.05373933e+00 -2.09953754e-01 1.07445202e+00 -0.19667083 0.64975541 115.25 9.76038842e-01 -2.26732826e-01 1.00202774e+00 -0.22825076 0.64118876 115.50 8.86276255e-01 -3.42603606e-01 9.50190945e-01 -0.36887132 0.60492813 115.75 8.06876286e-01 -3.94876559e-01 8.98318895e-01 -0.45512301 0.69658213 116.00 7.94145589e-01 -3.58079446e-01 8.71141841e-01 -0.42360128 0.70991121 116.25 7.84500520e-01 -3.39927993e-01 8.54980763e-01 -0.40888397 0.73633436 116.50 6.88622329e-01 -1.98091216e-01 7.16547865e-01 -0.28010044 0.55733835 116.75 7.10987298e-01 3.67380464e-02 7.11935827e-01 0.05162596 0.53047889 117.00 7.82434932e-01 3.30425303e-01 8.49344043e-01 0.39958479 0.46464636 117.25 7.96142710e-01 5.04805427e-01 9.42693871e-01 0.56509071 0.42342105 117.50 8.66064558e-01 5.69312898e-01 1.03642896e+00 0.58152916 0.39803123 117.75 9.83649999e-01 5.09954362e-01 1.10798049e+00 0.47828322 0.40572928 118.00 8.53841144e-01 3.81361835e-01 9.35137182e-01 0.42005841 0.25978076 118.25 9.34461473e-01 4.89757941e-01 1.05502658e+00 0.48274681 0.24685860 118.50 1.27801254e+00 6.76943920e-01 1.44622582e+00 0.48711253 0.25983031 118.75 1.51140899e+00 7.38915457e-01 1.68236536e+00 0.45472162 0.33024149 119.00 1.60986468e+00 1.60790873e-01 1.61787453e+00 0.09954836 0.49442881 119.25 1.28929815e+00 1.16819939e-01 1.29457970e+00 0.09036065 0.46660826 119.50 5.57789539e-01 1.19169617e-01 5.70377566e-01 0.21048182 0.21006349 119.75 1.82019098e-01 3.86582548e-01 4.27290321e-01 1.13074644 0.11885953 120.00 -4.39700949e-01 1.28119748e+00 1.35454934e+00 1.90139623 0.52511444 120.25 -4.08287729e-01 1.81708319e+00 1.86238830e+00 1.79181952 0.68401514 120.50 -5.01090399e-01 2.89072818e+00 2.93383725e+00 1.74243475 0.76165401 120.75 -2.03878413e-01 3.62599641e+00 3.63172361e+00 1.62696405 0.75691326 121.00 2.00988397e+00 4.67366693e+00 5.08751375e+00 1.16466085 0.84028943 121.25 2.16479503e+00 4.18992053e+00 4.71611827e+00 1.09390394 0.82107459 121.50 2.39388434e+00 3.37744460e+00 4.13978432e+00 0.95419824 0.79314814 121.75 2.26713292e+00 3.28566892e+00 3.99193085e+00 0.96680894 0.62957609 122.00 1.00704764e+00 4.09664891e+00 4.21861081e+00 1.32975347 0.46962765 122.25 5.29217244e-01 5.86193925e+00 5.88577969e+00 1.48076018 0.37810192 122.50 3.01254870e+00 1.32186199e+01 1.35575574e+01 1.34672153 0.39780188 122.75 1.24458992e+01 1.12517720e+01 1.67780446e+01 0.73505069 0.49810450 123.00 1.70580920e+01 1.94032446e+00 1.71680914e+01 0.11326123 0.66002172 123.25 1.44693227e+01 -1.24698871e+00 1.45229570e+01 -0.08596913 0.65270523 123.50 8.68964048e+00 -9.71050402e-01 8.74372864e+00 -0.11128635 0.40020621 123.75 5.18174201e+00 1.09689207e+00 5.29656704e+00 0.20860455 0.16277312 124.00 -1.71171656e-01 -1.03344002e+00 1.04751993e+00 -1.73493900 0.00360740 124.25 -3.08249051e+00 -6.12517347e+00 6.85707647e+00 -2.03704016 0.26061726 124.50 -3.43742234e+00 -6.67090643e+00 7.50445634e+00 -2.04659754 0.56287397 124.75 -1.80137129e+00 -5.35013085e+00 5.64524921e+00 -1.89557083 0.49612073 125.00 -9.45419491e-01 -4.22110732e+00 4.32568665e+00 -1.79113426 0.52272605 125.25 -5.23092283e-01 -3.47335657e+00 3.51252494e+00 -1.72027437 0.42099232 125.50 7.16914017e-01 -2.92727624e+00 3.01378697e+00 -1.33061564 0.41899911 125.75 9.30044609e-01 -2.30364512e+00 2.48430349e+00 -1.18708083 0.44741435 126.00 1.18535551e+00 -1.99050568e+00 2.31671762e+00 -1.03368874 0.52879696 126.25 2.00462654e+00 -8.70905935e-01 2.18563600e+00 -0.40984587 0.40478003 126.50 3.24208717e+00 6.60269312e-01 3.30863791e+00 0.20090811 0.59268955 126.75 4.48874025e+00 4.16046649e-01 4.50798002e+00 0.09242267 0.73740674 127.00 5.03983189e+00 -4.70661000e-01 5.06176128e+00 -0.09311815 0.75707186 127.25 4.90666802e+00 -1.29926732e+00 5.07577449e+00 -0.25885535 0.81649497 127.50 4.74863184e+00 -1.42321057e+00 4.95732112e+00 -0.29119036 0.81890723 127.75 4.28582289e+00 -7.29232974e-01 4.34741976e+00 -0.16853599 0.70641002 128.00 4.55674583e+00 -3.90004397e-01 4.57340529e+00 -0.08538028 0.77266707 128.25 4.89633768e+00 3.43017639e-01 4.90833819e+00 0.06994169 0.80644777 128.50 5.21261794e+00 6.89820629e-01 5.25806412e+00 0.13157217 0.77479591 128.75 6.45016525e+00 1.80159830e+00 6.69704324e+00 0.27236913 0.65903079 129.00 7.51569600e+00 2.49943273e+00 7.92040721e+00 0.32105593 0.70930519 129.25 1.10790107e+01 1.44597196e+00 1.11729724e+01 0.12978096 0.77991609 129.50 1.22466899e+01 1.17982238e-01 1.22472582e+01 0.00963351 0.81453428 129.75 1.41962462e+01 -3.36899518e+00 1.45905290e+01 -0.23300554 0.85951419 130.00 1.34661284e+01 -5.14144817e+00 1.44142674e+01 -0.36472415 0.86686359 130.25 1.28919494e+01 -6.17672862e+00 1.42952557e+01 -0.44680059 0.88842876 130.50 1.27221542e+01 -7.11131367e+00 1.45747724e+01 -0.50970454 0.88744080 130.75 1.31894656e+01 -8.17613178e+00 1.55180906e+01 -0.55492251 0.91055507 131.00 1.40133086e+01 -9.63149081e+00 1.70040710e+01 -0.60215850 0.90807780 131.25 1.31525323e+01 -1.48794720e+01 1.98591992e+01 -0.84692640 0.91236055 131.50 1.05235238e+01 -1.62485349e+01 1.93587045e+01 -0.99606796 0.89153587 131.75 4.12706658e+00 -1.59954829e+01 1.65193266e+01 -1.31828894 0.77771697 132.00 -4.26651290e-01 -1.39907967e+01 1.39973006e+01 -1.60128202 0.74208650 132.25 -3.58593799e+00 -1.03726204e+01 1.09749809e+01 -1.90364589 0.82910685 132.50 -1.94704315e+00 -8.32968577e+00 8.55421779e+00 -1.80042100 0.78484722 132.75 4.65295829e-01 -7.31727696e+00 7.33205580e+00 -1.50729317 0.66563180 133.00 -9.65919075e-01 -5.04369470e+00 5.13535353e+00 -1.76001547 0.38239174 133.25 -1.58709460e+00 -1.47875615e+00 2.16923697e+00 -2.39151695 0.26997088 133.50 2.15215541e-01 -1.33225097e+00 1.34952228e+00 -1.41063715 0.17574094 133.75 1.60419556e+00 -2.34798596e+00 2.84367394e+00 -0.97141977 0.68891711 134.00 1.17223875e+00 -2.37647318e+00 2.64986197e+00 -1.11254861 0.65294005 134.25 9.32491533e-01 -1.60787472e+00 1.85870965e+00 -1.04524781 0.59928430 134.50 1.25402399e+00 -1.30747631e+00 1.81164855e+00 -0.80626272 0.57714116 134.75 1.46286104e+00 -1.13332348e+00 1.85050926e+00 -0.65914185 0.70701175 135.00 1.59717267e+00 -1.07378809e+00 1.92457305e+00 -0.59189631 0.75553677 135.25 1.64962705e+00 -8.72577333e-01 1.86618879e+00 -0.48654185 0.83851270 135.50 1.88037454e+00 -7.03511854e-01 2.00766963e+00 -0.35801113 0.78400642 135.75 2.06642551e+00 -4.76300681e-01 2.12060763e+00 -0.22653844 0.79801320 136.00 1.62828769e+00 -4.45976675e-01 1.68825828e+00 -0.26733679 0.56429776 136.25 8.36240073e-01 -4.22905806e-01 9.37094862e-01 -0.46821549 0.26235178 136.50 -3.57798563e-01 -6.29907044e-01 7.24432671e-01 -2.08736765 0.08137408 136.75 -2.34409633e+00 -3.10808304e-01 2.36461190e+00 -3.00976963 0.44087240 137.00 -4.30295478e+00 6.06356251e-01 4.34546749e+00 3.00159819 0.52312584 137.25 -6.68977708e+00 3.07083908e+00 7.36092181e+00 2.71125101 0.65690404 137.50 -7.83948831e+00 5.28384661e+00 9.45392046e+00 2.54852753 0.66283277 137.75 -8.67356788e+00 6.91315166e+00 1.10915484e+01 2.46866123 0.67158273 138.00 -7.57642225e+00 7.31152557e+00 1.05290351e+01 2.37398531 0.47547675 138.25 -8.85648881e+00 6.89222762e+00 1.12223079e+01 2.48027886 0.44510227 138.50 -6.48096911e+00 7.47788891e+00 9.89554360e+00 2.28489711 0.29802231 138.75 -5.05643574e+00 8.28770469e+00 9.70842889e+00 2.11861864 0.23528331 139.00 -5.03674813e+00 8.69053866e+00 1.00446152e+01 2.09605594 0.26213323 139.25 -4.56758487e+00 9.46043457e+00 1.05053631e+01 2.02059696 0.26593013 139.50 -6.13142180e+00 7.59009133e+00 9.75724447e+00 2.25028694 0.24791919 139.75 -6.78743508e+00 7.53680212e+00 1.01426161e+01 2.30392752 0.25128221 140.00 -3.77260121e+00 5.40620958e+00 6.59239121e+00 2.18006269 0.12369073 140.25 -3.23971298e+00 3.99372970e+00 5.14253023e+00 2.25232924 0.08056393 140.50 -5.20864601e+00 2.69574083e+00 5.86489658e+00 2.66400290 0.14479614 140.75 -6.66544046e+00 2.53610046e+00 7.13161286e+00 2.77802186 0.17352986 141.00 -7.05064054e+00 1.86462275e+00 7.29303435e+00 2.88305018 0.13649662 141.25 -6.40397154e+00 2.08102498e+00 6.73361096e+00 2.82739829 0.11250414 141.50 -6.57928333e+00 3.78021059e+00 7.58794842e+00 2.62008710 0.17417816 141.75 -7.28813997e+00 2.15476965e+00 7.60000109e+00 2.85412753 0.16109573 142.00 -1.42549786e+01 1.26590381e+00 1.43110771e+01 3.05302067 0.29837205 142.25 -1.49480356e+01 2.15480197e+00 1.51025474e+01 2.99842603 0.28192555 142.50 -1.66476600e+01 5.82973738e+00 1.76388894e+01 2.80475429 0.26651543 142.75 -1.26862234e+01 8.77364435e+00 1.54245615e+01 2.53653443 0.21135502 143.00 -9.51941495e+00 1.20097495e+01 1.53249256e+01 2.24103369 0.24421934 143.25 -2.16980836e+00 1.14182139e+01 1.16225504e+01 1.75858766 0.17715460 143.50 2.27456941e+00 5.59548265e+00 6.04012351e+00 1.18469822 0.09433801 143.75 2.32516986e+00 4.75082935e+00 5.28930944e+00 1.11564527 0.09302400 144.00 5.29664512e+00 5.76585578e+00 7.82940243e+00 0.82778728 0.23734148 144.25 3.95228726e+00 4.24518612e+00 5.80018791e+00 0.82111335 0.17901561 144.50 4.51246846e+00 2.46386700e+00 5.14130452e+00 0.49977712 0.19874463 144.75 4.09170972e+00 2.44735236e+00 4.76776909e+00 0.53903941 0.19668666 145.00 3.77290971e+00 2.39596807e+00 4.46939712e+00 0.56579022 0.21436929 145.25 4.16664351e+00 2.31942343e+00 4.76871504e+00 0.50794567 0.28147602 145.50 5.35713265e+00 3.67628750e+00 6.49722710e+00 0.60143236 0.48797946 145.75 4.45672191e+00 2.98333111e+00 5.36308071e+00 0.58989275 0.45147342 146.00 3.82946293e+00 2.33463699e+00 4.48501017e+00 0.54748583 0.40944266 146.25 3.93749956e+00 2.89707318e+00 4.88844922e+00 0.63432809 0.47183854 146.50 4.46388251e+00 3.27463927e+00 5.53619991e+00 0.63291277 0.60543026 146.75 4.20695602e+00 2.81522738e+00 5.06201384e+00 0.58974330 0.59582517 147.00 4.81060207e+00 3.00515859e+00 5.67211341e+00 0.55837989 0.71113224 147.25 4.05671386e+00 1.77742631e+00 4.42901475e+00 0.41295116 0.50689058 147.50 4.11415540e+00 2.18561185e+00 4.65866653e+00 0.48832766 0.42953109 147.75 3.60297561e+00 2.25882106e+00 4.25249407e+00 0.55998748 0.41217076 148.00 3.72005978e+00 2.74326097e+00 4.62215594e+00 0.63540370 0.50885196 148.25 3.97937682e+00 2.73139440e+00 4.82658836e+00 0.60153150 0.57124158 148.50 5.03059558e+00 3.21327358e+00 5.96925615e+00 0.56842318 0.61430304 148.75 6.83199566e+00 4.69781603e+00 8.29129906e+00 0.60236874 0.75485066 149.00 7.65573619e+00 5.36267987e+00 9.34711892e+00 0.61104714 0.79761273 149.25 7.44051906e+00 4.28619370e+00 8.58677939e+00 0.52263137 0.68172880 149.50 7.44060261e+00 3.49091979e+00 8.21882523e+00 0.43868219 0.58714888 149.75 6.31628910e+00 1.89919206e+00 6.59563784e+00 0.29208202 0.44981202 150.00 6.35111857e+00 1.06439225e+00 6.43969238e+00 0.16604819 0.33339553 150.25 4.05971670e+00 9.39693493e-01 4.16705214e+00 0.22746195 0.28060098 150.50 4.42180806e+00 1.03973050e+00 4.54240311e+00 0.23094175 0.39356189 150.75 4.65778909e+00 1.93169319e-01 4.66179296e+00 0.04144857 0.51440783 151.00 4.05810737e+00 -1.86344851e-01 4.06238352e+00 -0.04588692 0.46027705 151.25 3.39721716e+00 -9.45791446e-01 3.52641545e+00 -0.27152610 0.41866684 151.50 2.91468658e+00 -1.16140075e+00 3.13755471e+00 -0.37918245 0.35732190 151.75 3.15359277e+00 -9.56716891e-01 3.29552038e+00 -0.29454899 0.38961584 152.00 2.74384668e+00 -8.15188029e-01 2.86238119e+00 -0.28879117 0.29078620 152.25 3.59598749e+00 -4.69974106e-01 3.62656886e+00 -0.12995744 0.44185448 152.50 3.57429987e+00 -4.82238281e-01 3.60668453e+00 -0.13410844 0.44661575 152.75 3.47640883e+00 -5.87252829e-02 3.47690480e+00 -0.01689091 0.35613545 153.00 3.37346270e+00 -1.89783192e-02 3.37351609e+00 -0.00562571 0.35144004 153.25 3.84016764e+00 -1.07970260e+00 3.98906571e+00 -0.27408430 0.50589383 153.50 3.54560308e+00 -7.74286940e-01 3.62916264e+00 -0.21500407 0.45424276 153.75 3.73152615e+00 -4.44100684e-01 3.75786014e+00 -0.11845597 0.41387883 154.00 2.93821539e+00 -2.28698653e-01 2.94710243e+00 -0.07767929 0.30730528 154.25 3.09597378e+00 6.15441204e-01 3.15655216e+00 0.19622952 0.33555516 154.50 2.41847055e+00 2.51144219e-01 2.43147553e+00 0.10347336 0.26188295 154.75 2.49720931e+00 -5.46303514e-02 2.49780680e+00 -0.02187307 0.30573011 155.00 2.04839752e+00 -1.24822487e-01 2.05219713e+00 -0.06086139 0.28037451 155.25 2.57017053e+00 -3.71438954e-01 2.59687186e+00 -0.14352548 0.39534323 155.50 2.42675619e+00 -4.48972911e-01 2.46793887e+00 -0.18294094 0.36242916 155.75 2.34466769e+00 -2.63220903e-01 2.35939649e+00 -0.11179554 0.31234120 156.00 2.01658618e+00 -1.34610992e-01 2.02107396e+00 -0.06665304 0.30158317 156.25 2.16751762e+00 -3.33927435e-01 2.19308918e+00 -0.15285807 0.32212866 156.50 2.03627332e+00 -7.19935462e-01 2.15979539e+00 -0.33983871 0.23297492 156.75 2.50954732e+00 -1.19756938e+00 2.78064744e+00 -0.44524616 0.25911798 157.00 2.31475623e+00 -1.03562937e+00 2.53586762e+00 -0.42069234 0.25963017 157.25 2.37489559e+00 -1.54239487e+00 2.83180349e+00 -0.57599409 0.30595990 157.50 1.59190268e+00 -1.04077375e+00 1.90193694e+00 -0.57903656 0.12488257 157.75 1.71655869e+00 -1.52068607e+00 2.29326402e+00 -0.72496587 0.11489960 158.00 2.53567335e+00 -2.13826612e+00 3.31689936e+00 -0.70057599 0.31029202 158.25 3.22110208e+00 -3.01993110e+00 4.41536890e+00 -0.75317572 0.47018056 158.50 2.37698602e+00 -2.57283652e+00 3.50279179e+00 -0.82494471 0.34690477 158.75 2.52845174e+00 -3.14461660e+00 4.03505660e+00 -0.89358635 0.38878300 159.00 1.69921621e+00 -4.13243574e+00 4.46814960e+00 -1.18068078 0.43353037 159.25 1.37457095e+00 -4.47252093e+00 4.67898373e+00 -1.27262205 0.47730191 159.50 1.21741700e-01 -3.28193362e+00 3.28419082e+00 -1.53371882 0.42583792 159.75 -3.61068777e-01 -3.59880440e+00 3.61687210e+00 -1.67079190 0.53352814 160.00 7.64303849e-02 -2.91718621e+00 2.91818728e+00 -1.54460228 0.46290365 160.25 5.63778287e-02 -2.51410015e+00 2.51473219e+00 -1.54837543 0.44743535 160.50 -1.46004845e-01 -1.90503064e+00 1.91061748e+00 -1.64728852 0.36537321 160.75 -1.12313721e-01 -1.56527934e+00 1.56930360e+00 -1.64242671 0.31278194 161.00 1.77348068e-01 -1.28259116e+00 1.29479436e+00 -1.43339433 0.38158526 161.25 1.51695411e-01 -1.24248553e+00 1.25171155e+00 -1.44930730 0.34276550 161.50 2.23925605e-01 -8.89661084e-01 9.17409135e-01 -1.32422051 0.33368527 161.75 3.44135057e-01 -6.81600053e-01 7.63549324e-01 -1.10324203 0.26674193 162.00 3.58876302e-01 -1.62928383e-01 3.94129240e-01 -0.42617198 0.08431597 162.25 4.36035639e-01 -9.75749597e-02 4.46819820e-01 -0.22015053 0.09430026 162.50 8.75295615e-01 -6.47736600e-01 1.08890088e+00 -0.63708350 0.24788245 162.75 1.19222883e+00 -8.56511159e-01 1.46799896e+00 -0.62297624 0.33517339 163.00 1.55367965e+00 -1.29280121e+00 2.02120148e+00 -0.69400402 0.46203414 163.25 1.76695586e+00 -1.29855097e+00 2.19279904e+00 -0.63377241 0.46588254 163.50 1.99701954e+00 -1.70233714e+00 2.62412629e+00 -0.70590827 0.52239936 163.75 2.02970359e+00 -1.74631116e+00 2.67755473e+00 -0.71048793 0.49420676 164.00 2.37769159e+00 -2.19467484e+00 3.23574025e+00 -0.74539282 0.54852422 164.25 1.34133267e+00 -2.23520280e+00 2.60678056e+00 -1.03030742 0.45081014 164.50 3.02401298e-01 -2.85592986e+00 2.87189518e+00 -1.46530400 0.51100384 164.75 8.63139412e-02 -2.29520584e+00 2.29682823e+00 -1.53320785 0.45028879 165.00 4.56895423e-02 -2.16659096e+00 2.16707266e+00 -1.54971123 0.47129416 165.25 7.94127020e-02 -1.73302995e+00 1.73484847e+00 -1.52500532 0.39943622 165.50 2.01500158e-02 -1.10093560e+00 1.10111999e+00 -1.55249574 0.34826141 165.75 1.07222551e-01 -7.91224204e-01 7.98456271e-01 -1.43610210 0.23561652 166.00 3.73263584e-01 -7.69675701e-01 8.55410070e-01 -1.11925121 0.28030259 166.25 5.12294765e-01 -6.25668112e-01 8.08644862e-01 -0.88469882 0.31693234 166.50 6.97652939e-01 -6.98348473e-01 9.87122188e-01 -0.78589640 0.52060244 166.75 6.61409464e-01 -6.37165512e-01 9.18391185e-01 -0.76673067 0.50265886 167.00 7.92724086e-01 -6.67652488e-01 1.03642237e+00 -0.69996325 0.62744737 167.25 8.99516899e-01 -6.84893589e-01 1.13057944e+00 -0.65075828 0.55976140 167.50 1.09877332e+00 -8.16413492e-01 1.36888049e+00 -0.63902065 0.59931053 167.75 9.51744670e-01 -6.18664014e-01 1.13514892e+00 -0.57639736 0.51463523 168.00 9.61252240e-01 -5.58148380e-01 1.11154644e+00 -0.52606791 0.49177145 168.25 7.07806431e-01 -4.83346030e-01 8.57095869e-01 -0.59914259 0.30202336 168.50 7.13354733e-01 -4.23830156e-01 8.29763205e-01 -0.53609702 0.24847708 168.75 5.38038746e-01 -3.13826325e-01 6.22874510e-01 -0.52803339 0.18862573 169.00 5.77736412e-01 -2.68158445e-01 6.36936664e-01 -0.43456154 0.20313479 169.25 3.82785992e-01 -1.81145603e-01 4.23484174e-01 -0.44200273 0.09284535 169.50 3.22756186e-01 -2.11144174e-01 3.85685647e-01 -0.57931576 0.07834831 169.75 -1.52868072e-03 4.49702699e-02 4.49962448e-02 1.60477638 0.00104550 170.00 -1.31384951e-01 -1.93586174e-02 1.32803469e-01 -2.99530251 0.00845514 170.25 1.33903308e-02 -3.25699453e-01 3.25974592e-01 -1.52970693 0.06449494 170.50 -7.40388572e-02 -4.11040901e-01 4.17655809e-01 -1.74901061 0.12303692 170.75 -1.25808971e-02 -4.21476735e-01 4.21664460e-01 -1.60063703 0.12280870 171.00 -5.07668061e-02 -5.09931578e-01 5.12452420e-01 -1.67002547 0.22936289 171.25 1.55344036e-01 -5.99087485e-01 6.18900302e-01 -1.31708304 0.31937035 171.50 2.33315714e-01 -6.96731010e-01 7.34758683e-01 -1.24766160 0.32462949 171.75 4.06167992e-01 -1.19324640e+00 1.26047983e+00 -1.24270914 0.32723701 172.00 5.22976386e-01 -1.27318231e+00 1.37640746e+00 -1.18104594 0.26372640 172.25 -9.87199316e-01 -2.05808008e+00 2.28259854e+00 -2.01804808 0.28208479 172.50 -1.45035584e+00 -1.66881810e+00 2.21099207e+00 -2.28627018 0.25657108 172.75 -2.03564038e+00 -2.04180411e+00 2.88319194e+00 -2.35468283 0.45595002 173.00 -2.24556132e+00 -1.51452513e+00 2.70856641e+00 -2.54821900 0.48352283 173.25 -2.35012022e+00 -8.92094944e-01 2.51374192e+00 -2.77879919 0.61606390 173.50 -2.13938523e+00 -6.94111002e-01 2.24916857e+00 -2.82786359 0.66468072 173.75 -1.67969807e+00 -8.18523333e-01 1.86851975e+00 -2.68815346 0.72688933 174.00 -1.53612982e+00 -8.44025422e-01 1.75273322e+00 -2.63917236 0.67596376 174.25 -1.80831114e+00 -6.24654107e-01 1.91316020e+00 -2.80899035 0.60224600 174.50 -1.56981469e+00 -3.25632098e-01 1.60323249e+00 -2.93705986 0.48459962 174.75 -1.31104410e+00 -1.07303355e-01 1.31542793e+00 -3.05992895 0.50191149 175.00 -1.18756480e+00 -9.50072316e-02 1.19135911e+00 -3.06176095 0.47829491 175.25 -1.29142930e+00 2.09845658e-01 1.30836724e+00 2.98050950 0.43422800 175.50 -6.85764546e-01 5.78238520e-01 8.97013266e-01 2.44105803 0.28417167 175.75 6.13272217e-02 1.54132818e-01 1.65885363e-01 1.19211408 0.02426028 176.00 2.46419885e-02 -7.72898856e-01 7.73291580e-01 -1.53892457 0.22566518 176.25 -4.03497661e-01 -1.55654287e+00 1.60799131e+00 -1.82444003 0.52768430 176.50 -8.28215390e-01 -1.39799322e+00 1.62490792e+00 -2.10563226 0.55318778 176.75 -1.36326005e+00 -1.15569641e+00 1.78720793e+00 -2.43840939 0.69480588 177.00 -1.39923864e+00 -9.17936222e-01 1.67346218e+00 -2.56099324 0.57001909 177.25 -1.44426768e+00 -7.05216164e-01 1.60724577e+00 -2.68735982 0.46791850 177.50 -1.15046500e+00 -5.54481898e-01 1.27711389e+00 -2.69247825 0.39164499 177.75 -1.47565397e+00 -1.70848444e-01 1.48551130e+00 -3.02632773 0.54141057 178.00 -1.52313152e+00 -2.99912541e-01 1.55237791e+00 -2.94717461 0.60465264 178.25 -1.66793058e+00 -4.35756941e-01 1.72391314e+00 -2.88604845 0.74161114 178.50 -1.48867172e+00 -3.10905560e-01 1.52079116e+00 -2.93570441 0.72139725 178.75 -1.39626179e+00 -4.22657589e-01 1.45883049e+00 -2.84765464 0.66701240 179.00 -1.33103934e+00 -4.95696370e-01 1.42034525e+00 -2.78509196 0.64328357 179.25 -1.34042009e+00 -4.62802859e-01 1.41806647e+00 -2.80914050 0.64940725 179.50 -1.21186568e+00 -4.38693345e-01 1.28882515e+00 -2.79426915 0.63805797 179.75 -1.20700450e+00 -4.08294381e-01 1.27419157e+00 -2.81540498 0.64994919 180.00 -9.91855374e-01 -4.38702915e-01 1.08454476e+00 -2.72515602 0.61638852 180.25 -8.82822654e-01 -4.76973538e-01 1.00343390e+00 -2.64624078 0.57601053 180.50 -5.86704600e-01 -6.02712403e-01 8.41120995e-01 -2.34273677 0.39488850 180.75 -4.77165519e-01 -6.45525574e-01 8.02739185e-01 -2.20734253 0.36373708 181.00 -3.44559645e-01 -6.18210708e-01 7.07747009e-01 -2.07926490 0.30136927 181.25 -2.01345956e-01 -8.05294752e-01 8.30084232e-01 -1.81580102 0.38201632 181.50 -2.00538856e-01 -7.96515684e-01 8.21372673e-01 -1.81744030 0.29024508 181.75 -1.30379790e-01 -7.97819535e-01 8.08402684e-01 -1.73278458 0.25311233 182.00 3.66160080e-03 -9.03252589e-01 9.03260011e-01 -1.56674255 0.17175052 182.25 -3.25883478e-02 -1.06944549e+00 1.06994190e+00 -1.60125909 0.19047075 182.50 2.41972913e-01 -6.05667901e-01 6.52215070e-01 -1.19070883 0.08517231 182.75 2.26325547e-01 -4.38145373e-01 4.93147667e-01 -1.09399375 0.06548411 183.00 1.97855155e-01 8.69748314e-02 2.16127933e-01 0.41416199 0.01351619 183.25 3.74845562e-01 5.94058386e-02 3.79523713e-01 0.15717367 0.04669287 183.50 4.94167993e-01 -5.69991593e-02 4.97444378e-01 -0.11483622 0.08594178 183.75 2.53987479e-01 -4.06404910e-02 2.57218368e-01 -0.15866484 0.03137448 184.00 2.37927651e-01 -1.46323213e-01 2.79320694e-01 -0.55136897 0.03573462 184.25 1.70528076e-01 1.77501335e-03 1.70537313e-01 0.01040855 0.02149178 184.50 5.80070129e-03 -1.42695142e-01 1.42812996e-01 -1.53016769 0.02395898 184.75 -1.04864108e-01 -2.09034965e-01 2.33863417e-01 -2.03576963 0.06807113 185.00 -3.86934629e-01 -2.28012756e-01 4.49119387e-01 -2.60909296 0.30808626 185.25 -4.54755699e-01 -8.64157848e-02 4.62893545e-01 -2.95380481 0.34315949 185.50 -4.85900365e-01 3.92499647e-02 4.87483050e-01 3.06098986 0.47932872 185.75 -5.81257493e-01 1.01591920e-01 5.90068802e-01 2.96856090 0.55399329 186.00 -7.11224562e-01 1.48090356e-01 7.26478582e-01 2.93630699 0.81005336 186.25 -7.27953776e-01 1.70659680e-01 7.47690729e-01 2.91131380 0.78241266 186.50 -7.96018804e-01 1.59086189e-01 8.11760034e-01 2.94433912 0.79919106 186.75 -8.03455673e-01 2.28101158e-01 8.35207254e-01 2.86497105 0.78775044 187.00 -8.20265179e-01 2.56656332e-01 8.59480911e-01 2.83834857 0.83709023 187.25 -8.64430922e-01 2.79190980e-01 9.08398823e-01 2.82919192 0.78896783 187.50 -9.13595888e-01 4.29133369e-01 1.00936262e+00 2.70246193 0.82907946 187.75 -8.81825382e-01 4.90313100e-01 1.00897123e+00 2.63413884 0.82054146 188.00 -9.09355103e-01 6.07123117e-01 1.09340074e+00 2.55291554 0.84845673 188.25 -6.80426514e-01 7.23635648e-01 9.93291897e-01 2.32542983 0.72391828 188.50 -4.71070919e-01 8.25990830e-01 9.50877837e-01 2.08909889 0.73307835 188.75 -2.18425148e-01 6.87272432e-01 7.21146962e-01 1.87851553 0.63169487 189.00 -4.88832122e-02 5.81927743e-01 5.83977282e-01 1.65460178 0.62983361 189.25 -1.01459111e-01 4.13210413e-01 4.25484191e-01 1.81157165 0.54663168 189.50 -1.69240682e-01 2.87859014e-01 3.33923973e-01 2.10229286 0.49735941 189.75 -2.83792075e-01 6.77981090e-02 2.91778213e-01 2.90708742 0.40054916 190.00 -3.66809523e-01 -2.83989989e-02 3.67907229e-01 -3.06432514 0.47629599 190.25 -4.89288174e-01 7.00465162e-02 4.94276676e-01 2.99939877 0.50768951 190.50 -5.65715637e-01 1.15881832e-01 5.77462363e-01 2.93954652 0.64948608 190.75 -6.73298894e-01 9.02954873e-02 6.79326634e-01 3.00827901 0.66998923 191.00 -7.08606777e-01 1.51239418e-01 7.24566716e-01 2.93131562 0.70744396 191.25 -8.61764001e-01 1.97943426e-01 8.84205176e-01 2.91581336 0.76790764 191.50 -9.67577362e-01 2.39057942e-01 9.96671787e-01 2.89937489 0.81200939 191.75 -1.00171797e+00 4.53858075e-01 1.09973908e+00 2.71618060 0.82378085 192.00 -9.95632027e-01 5.31754406e-01 1.12873641e+00 2.65104852 0.82679848 192.25 -8.08042257e-01 6.88121476e-01 1.06134041e+00 2.43617568 0.77392940 192.50 -7.68553390e-01 7.11448298e-01 1.04729795e+00 2.39475984 0.78277365 192.75 -8.09733553e-01 8.18366819e-01 1.15125700e+00 2.35089188 0.77680291 193.00 -7.27004195e-01 9.15956065e-01 1.16940609e+00 2.24169059 0.80282024 193.25 -5.28332434e-01 9.53677036e-01 1.09024541e+00 2.07670164 0.82476534 193.50 -3.94968927e-01 9.44533680e-01 1.02378920e+00 1.96686165 0.77042321 193.75 -4.08796276e-02 8.26454935e-01 8.27465349e-01 1.62021988 0.67437289 194.00 4.81494851e-02 7.83108778e-01 7.84587619e-01 1.50938858 0.67515838 194.25 1.07121949e-01 7.71258137e-01 7.78661818e-01 1.43278679 0.67875475 194.50 2.22683875e-01 6.05628545e-01 6.45270519e-01 1.21844932 0.51044368 194.75 4.42920026e-01 2.79582537e-01 5.23779099e-01 0.56306376 0.43526582 195.00 3.61487615e-01 9.83016737e-02 3.74615156e-01 0.26551587 0.20097453 195.25 2.66090720e-01 -4.26938980e-01 5.03071729e-01 -1.01345474 0.26850368 195.50 6.03368618e-02 -5.94534295e-01 5.97588123e-01 -1.46965668 0.24804007 195.75 -5.00332768e-01 -7.85124860e-01 9.30996200e-01 -2.13816700 0.34329125 196.00 -7.91184706e-01 -3.95644565e-01 8.84594744e-01 -2.67789225 0.23796505 196.25 -1.12844276e+00 9.49729346e-01 1.47491318e+00 2.44197892 0.41037259 196.50 -9.50339092e-01 1.31703788e+00 1.62410996e+00 2.19585463 0.57920777 196.75 -9.43492493e-01 1.89858486e+00 2.12009494e+00 2.03199705 0.66387907 197.00 2.84223327e-01 2.14209351e+00 2.16086730e+00 1.43888202 0.49280747 197.25 2.06719938e+00 1.00356025e+00 2.29792220e+00 0.45195500 0.53033081 197.50 1.37808350e+00 -6.20635733e-01 1.51139103e+00 -0.42315450 0.38149295 197.75 1.91032982e-01 -1.49796091e+00 1.51009287e+00 -1.44395233 0.62403310 198.00 -4.51902128e-01 -1.08341927e+00 1.17388792e+00 -1.96596287 0.62490120 198.25 -7.21938758e-01 -7.72496113e-01 1.05732957e+00 -2.32237697 0.76526664 198.50 -8.69015266e-01 -7.04189774e-01 1.11851275e+00 -2.46058415 0.73464115 198.75 -1.10975414e+00 -6.16922718e-01 1.26970386e+00 -2.63422383 0.79004096 199.00 -1.20172745e+00 -2.57336124e-01 1.22897142e+00 -2.93064007 0.72383498 199.25 -1.32518323e+00 -9.61916767e-02 1.32866980e+00 -3.06913228 0.80188693 199.50 -1.32785118e+00 5.57140496e-02 1.32901949e+00 3.09965920 0.74041547 199.75 -1.28083822e+00 2.87219871e-01 1.31264687e+00 2.92099821 0.63218072 200.00 -7.61234316e-01 7.81036967e-01 1.09064037e+00 2.34335527 0.34800233 200.25 -9.38125917e-01 7.87475641e-01 1.22482575e+00 2.44327674 0.38796072 200.50 -1.57400724e+00 8.25566967e-01 1.77737436e+00 2.65853761 0.62263166 200.75 -1.65883925e+00 1.09782659e+00 1.98921364e+00 2.55696401 0.65295032 201.00 -1.07252659e+00 1.40453208e+00 1.76720787e+00 2.22295641 0.53271921 201.25 -1.03469889e+00 1.69423263e+00 1.98520175e+00 2.11905969 0.64839417 201.50 -8.10023230e-01 1.77666960e+00 1.95261171e+00 1.99856428 0.71673247 201.75 -5.26699770e-01 2.08874343e+00 2.15412668e+00 1.81780790 0.79454358 202.00 -1.44920898e-01 2.37556863e+00 2.37998495e+00 1.63172554 0.81074503 202.25 1.87348369e-01 2.31270866e+00 2.32028463e+00 1.48996463 0.80592962 202.50 5.21915370e-01 2.22473699e+00 2.28513683e+00 1.34036684 0.80072729 202.75 7.96662979e-01 2.21761571e+00 2.35637250e+00 1.22591103 0.79589759 203.00 1.46239697e+00 1.99741971e+00 2.47553841e+00 0.93882196 0.82008351 203.25 1.94636726e+00 1.93177017e+00 2.74227670e+00 0.78163424 0.82528293 203.50 2.23273565e+00 5.37850429e-01 2.29660436e+00 0.23638919 0.77828251 203.75 1.97738629e+00 -1.36856375e-01 1.98211660e+00 -0.06910055 0.76110173 204.00 1.26250076e+00 -7.42146296e-01 1.46447578e+00 -0.53142907 0.69345784 204.25 7.32389048e-01 -7.11409157e-01 1.02102728e+00 -0.77086814 0.50242426 204.50 -2.87752764e-02 -5.74917011e-01 5.75636679e-01 -1.62080578 0.26109466 204.75 -2.98505410e-01 -4.43844228e-01 5.34886136e-01 -2.16285781 0.13791634 205.00 -9.27810015e-01 7.55902497e-01 1.19675395e+00 2.45794219 0.20022335 205.25 -7.91991580e-01 1.59015594e+00 1.77647025e+00 2.03288998 0.31710224 205.50 9.26835139e-01 2.93050711e+00 3.07358020e+00 1.26447943 0.66898792 205.75 1.58660584e+00 2.53203170e+00 2.98806001e+00 1.01103742 0.70770596 206.00 2.16475088e+00 1.28675113e+00 2.51830793e+00 0.53629960 0.73063415 206.25 2.02349175e+00 8.92916561e-01 2.21174565e+00 0.41557467 0.74211549 206.50 2.14429040e+00 6.28823609e-01 2.23459178e+00 0.28525717 0.77163516 206.75 1.95198458e+00 1.33403117e-01 1.95653781e+00 0.06823620 0.69732393 207.00 1.66478794e+00 -1.28995492e-01 1.66977805e+00 -0.07733013 0.73466487 207.25 1.42123669e+00 -2.48586322e-01 1.44281283e+00 -0.17315685 0.66743695 207.50 1.39973280e+00 -4.70007825e-01 1.47653624e+00 -0.32395450 0.78148553 207.75 1.18591171e+00 -5.84167298e-01 1.32198261e+00 -0.45770141 0.71913002 208.00 8.85773519e-01 -5.27660354e-01 1.03102870e+00 -0.53725596 0.69014599 208.25 8.06189011e-01 -3.31905926e-01 8.71838440e-01 -0.39054950 0.61555759 208.50 7.60655946e-01 -2.19152988e-01 7.91596804e-01 -0.28051365 0.64554932 208.75 7.21333768e-01 -2.99308235e-02 7.21954472e-01 -0.04146993 0.64601984 209.00 7.21388996e-01 1.07800512e-01 7.29399091e-01 0.14833699 0.70681175 209.25 7.77561007e-01 2.80509279e-01 8.26611502e-01 0.34622409 0.69560285 209.50 8.90693298e-01 4.61171094e-01 1.00300216e+00 0.47775953 0.76386532 209.75 1.08743204e+00 5.19726929e-01 1.20524874e+00 0.44584412 0.80810248 210.00 1.18697624e+00 5.82315595e-01 1.32212104e+00 0.45608922 0.85579993 210.25 1.04153943e+00 7.45034426e-01 1.28057826e+00 0.62093430 0.79278561 210.50 9.16825925e-01 1.10969931e+00 1.43944515e+00 0.88028678 0.77059993 210.75 8.70569028e-01 2.07863138e+00 2.25357468e+00 1.17417320 0.67685265 211.00 1.42025164e+00 3.03811392e+00 3.35369214e+00 1.13350307 0.75424185 211.25 2.69836780e+00 3.35943073e+00 4.30893996e+00 0.89409399 0.70816682 211.50 3.14564487e+00 3.54335730e+00 4.73819191e+00 0.84478591 0.73188327 211.75 3.10001326e+00 3.01514102e+00 4.32448351e+00 0.77152005 0.58464305 212.00 3.10977299e+00 2.92637662e+00 4.27017191e+00 0.75502450 0.54967129 212.25 3.02744238e+00 2.39265113e+00 3.85878048e+00 0.66881115 0.44607549 212.50 3.01126643e+00 2.02350727e+00 3.62798941e+00 0.59167124 0.41052354 212.75 2.90475778e+00 2.32875270e+00 3.72299704e+00 0.67577843 0.40882217 213.00 3.55222829e+00 2.26353595e+00 4.21211596e+00 0.56733551 0.49631996 213.25 3.67726292e+00 1.31502316e+00 3.90532310e+00 0.34343749 0.48452456 213.50 3.40399527e+00 1.49431441e+00 3.71754750e+00 0.41365903 0.46104368 213.75 2.42711618e+00 2.55335191e+00 3.52285381e+00 0.81073890 0.49658645 214.00 1.53377791e+00 3.02743204e+00 3.39379131e+00 1.10186142 0.38604027 214.25 8.63735055e-01 3.28617485e+00 3.39779096e+00 1.31377084 0.15609601 214.50 1.85445297e+00 2.33869788e+00 2.98471164e+00 0.90037357 0.09278020 214.75 5.38531950e+00 5.17175846e-01 5.41009584e+00 0.09574078 0.18969800 215.00 4.33100399e+00 -8.81972274e-01 4.41989487e+00 -0.20089457 0.15452240 215.25 9.72784301e-02 -1.56477165e+00 1.56779253e+00 -1.50870842 0.01777152 215.50 -4.53191643e-01 -1.15387355e+00 1.23968013e+00 -1.94504298 0.01269520 215.75 -6.09600067e-01 -3.85980495e+00 3.90764718e+00 -1.72743794 0.18161561 216.00 -1.32720467e+00 -3.06924128e+00 3.34390704e+00 -1.97893588 0.17997945 216.25 -2.52067190e+00 -3.56708884e+00 4.36782665e+00 -2.18596931 0.45285466 216.50 -2.08672207e+00 -2.53278020e+00 3.28167404e+00 -2.25993314 0.45957409 216.75 -1.98009411e+00 -1.93696560e+00 2.76994737e+00 -2.36720447 0.57286202 217.00 -1.59335453e+00 -1.39232633e+00 2.11597525e+00 -2.42342379 0.58660313 217.25 -1.16632369e+00 -1.16047736e+00 1.64530200e+00 -2.35870709 0.72264863 217.50 -6.84481019e-01 -1.13615952e+00 1.32641348e+00 -2.11301646 0.69589094 217.75 -3.15581358e-01 -1.19975677e+00 1.24056757e+00 -1.82800770 0.80829993 218.00 -9.22169830e-02 -1.09951547e+00 1.10337584e+00 -1.65447106 0.78811626 218.25 1.43214621e-01 -1.09087300e+00 1.10023376e+00 -1.44025846 0.76695940 218.50 2.09125460e-01 -1.04104011e+00 1.06183707e+00 -1.37255354 0.65192965 218.75 2.69739717e-01 -1.07748856e+00 1.11073899e+00 -1.32549661 0.58908097 219.00 3.66321150e-01 -1.04677878e+00 1.10902525e+00 -1.23416527 0.56185173 219.25 4.43117209e-01 -1.17789730e+00 1.25848913e+00 -1.21097978 0.64043399 219.50 3.71500477e-01 -1.12750720e+00 1.18713314e+00 -1.25251025 0.61626644 219.75 3.24926202e-01 -1.25105669e+00 1.29256330e+00 -1.31668924 0.67884415 220.00 4.26786595e-01 -9.89904786e-01 1.07798807e+00 -1.16373737 0.48690550 220.25 5.84480551e-01 -1.02827634e+00 1.18278051e+00 -1.05393018 0.46602255 220.50 4.25235491e-01 -1.27304314e+00 1.34218630e+00 -1.24841827 0.48973980 220.75 3.95670750e-01 -1.73455058e+00 1.77910681e+00 -1.34652240 0.57247923 221.00 -8.65125145e-02 -1.51347430e+00 1.51594488e+00 -1.62789573 0.46774330 221.25 -4.43394270e-01 -1.53841765e+00 1.60103946e+00 -1.85140597 0.48422630 221.50 -7.71846784e-01 -1.71561331e+00 1.88124333e+00 -1.99356338 0.56175203 221.75 -8.56772274e-01 -1.91203671e+00 2.09521911e+00 -1.99206413 0.62919407 222.00 -7.73874293e-01 -1.58361568e+00 1.76258902e+00 -2.02534342 0.56387221 222.25 -1.07093946e+00 -1.57613033e+00 1.90554406e+00 -2.16761316 0.57055813 222.50 -2.17659995e+00 -1.37793664e+00 2.57610107e+00 -2.57721237 0.70108071 222.75 -2.57169279e+00 -1.16903690e+00 2.82493382e+00 -2.71493756 0.75916758 223.00 -2.58062588e+00 2.35592144e-01 2.59135748e+00 3.05055238 0.57083002 223.25 -2.64347057e+00 1.04606261e+00 2.84291816e+00 2.76478515 0.66486893 223.50 -1.89350080e+00 1.34443202e+00 2.32224949e+00 2.52417045 0.71733243 223.75 -1.37268951e+00 1.27370913e+00 1.87259484e+00 2.39357898 0.70047343 224.00 -7.98871432e-01 1.22262415e+00 1.46048121e+00 2.14956305 0.67081235 224.25 -5.71460898e-01 1.15381480e+00 1.28757763e+00 2.03066046 0.72378849 224.50 -2.19506678e-01 9.78301560e-01 1.00262512e+00 1.79151606 0.69509135 224.75 -6.47517043e-02 8.72100473e-01 8.74501011e-01 1.64490833 0.62203153 225.00 2.53729319e-01 6.00576203e-01 6.51974189e-01 1.17106507 0.50443670 225.25 2.45294561e-01 4.92753808e-01 5.50432318e-01 1.10890748 0.51852612 225.50 2.80750709e-01 3.43665231e-01 4.43764297e-01 0.88581665 0.48903803 225.75 2.61929949e-01 3.80592841e-01 4.62015378e-01 0.96802319 0.49012864 226.00 1.47367751e-01 4.48628662e-01 4.72212802e-01 1.25341567 0.48442132 226.25 2.51320370e-01 5.55381503e-01 6.09598673e-01 1.14585004 0.50601314 226.50 5.60211822e-01 5.73462600e-01 8.01683628e-01 0.79708598 0.67065967 226.75 7.10732669e-01 4.64386164e-01 8.48996724e-01 0.57875520 0.66266883 227.00 9.65802402e-01 3.29365149e-01 1.02041937e+00 0.32865922 0.71081745 227.25 9.55857710e-01 1.79748120e-01 9.72611612e-01 0.18587829 0.52869336 227.50 1.31341822e+00 -2.20290305e-01 1.33176396e+00 -0.16617618 0.67080435 227.75 1.31438977e+00 -4.40052592e-01 1.38609767e+00 -0.32306648 0.67992605 228.00 1.33621369e+00 -6.61417818e-01 1.49095290e+00 -0.45963483 0.72134264 228.25 1.20562714e+00 -9.41685875e-01 1.52980688e+00 -0.66309465 0.72782945 228.50 1.16154986e+00 -1.21338146e+00 1.67972993e+00 -0.80721916 0.79311537 228.75 8.32998481e-01 -1.37894862e+00 1.61102010e+00 -1.02738053 0.73017588 229.00 6.46208517e-01 -1.58312443e+00 1.70993229e+00 -1.18325342 0.78054439 229.25 2.71232994e-01 -1.31907166e+00 1.34666899e+00 -1.36799882 0.73903021 229.50 1.74077779e-01 -1.41907231e+00 1.42970951e+00 -1.44873602 0.86486137 229.75 1.88540348e-01 -1.39173552e+00 1.40444837e+00 -1.43614467 0.75126181 230.00 1.94822021e-01 -1.56520975e+00 1.57728792e+00 -1.44696298 0.77779538 230.25 9.43969205e-02 -1.46996538e+00 1.47299321e+00 -1.50666728 0.66225013 230.50 -1.44748100e-01 -1.55783656e+00 1.56454682e+00 -1.66344641 0.68674256 230.75 -3.14859161e-01 -1.41510867e+00 1.44971336e+00 -1.78972827 0.63663156 231.00 -5.39178141e-01 -1.40518751e+00 1.50507973e+00 -1.93717727 0.64416750 231.25 -6.98811039e-01 -1.13569055e+00 1.33346537e+00 -2.12240312 0.53158611 231.50 -8.52758604e-01 -1.10538012e+00 1.39608827e+00 -2.22789213 0.56032957 231.75 -1.08966467e+00 -8.07925501e-01 1.35650754e+00 -2.50358981 0.51519277 232.00 -1.15539096e+00 -7.17205476e-01 1.35989410e+00 -2.58605752 0.54632068 232.25 -1.16260536e+00 -6.13842736e-01 1.31470686e+00 -2.65580544 0.58320918 232.50 -1.28880876e+00 -5.32699374e-01 1.39455966e+00 -2.74965059 0.62050190 232.75 -1.16355167e+00 -3.22350056e-01 1.20737818e+00 -2.87133110 0.59251387 233.00 -1.23265564e+00 -3.12816595e-01 1.27172880e+00 -2.89306467 0.61422014 233.25 -1.14076341e+00 -1.13156564e-01 1.14636188e+00 -3.04272236 0.55118847 233.50 -1.13359271e+00 -6.34640859e-02 1.13536783e+00 -3.08566612 0.64129657 233.75 -1.14186668e+00 -9.03366544e-02 1.14543452e+00 -3.06264395 0.69606437 234.00 -1.14948415e+00 -7.19355607e-02 1.15173284e+00 -3.07909343 0.64632279 234.25 -1.05043637e+00 -3.76472623e-02 1.05111079e+00 -3.10576835 0.56414736 234.50 -1.03061936e+00 3.91353243e-02 1.03136213e+00 3.10363826 0.55180946 234.75 -1.02618187e+00 1.79665108e-01 1.04179114e+00 2.96826824 0.71132443 235.00 -1.02107910e+00 2.52033972e-01 1.05172414e+00 2.89959880 0.69993735 235.25 -8.56776512e-01 3.24432992e-01 9.16145598e-01 2.77961096 0.56365581 235.50 -8.42259764e-01 3.69393993e-01 9.19702904e-01 2.72828036 0.59576412 235.75 -7.93625157e-01 3.31544525e-01 8.60094565e-01 2.74587064 0.55211138 236.00 -7.13822215e-01 2.11481035e-01 7.44490686e-01 2.85356534 0.45772695 236.25 -6.56342039e-01 3.56688949e-01 7.47001927e-01 2.64379229 0.44540706 236.50 -7.08119029e-01 5.06134215e-01 8.70404735e-01 2.52103006 0.52935409 236.75 -5.19403965e-01 7.70747426e-01 9.29425669e-01 2.16378749 0.56399468 237.00 -2.38253259e-01 6.91581649e-01 7.31470978e-01 1.90256736 0.53656870 237.25 -2.04765385e-01 4.57497702e-01 5.01231494e-01 1.99163334 0.51178466 237.50 -2.49430125e-01 3.31718829e-01 4.15033455e-01 2.21553300 0.41206258 237.75 -2.88460091e-01 1.57450992e-01 3.28633594e-01 2.64195442 0.40166340 238.00 -3.89528610e-01 1.69695829e-01 4.24887294e-01 2.73074104 0.49371508 238.25 -6.06264193e-01 1.75027515e-01 6.31023694e-01 2.86053626 0.63540669 238.50 -6.04107467e-01 2.30327789e-01 6.46526660e-01 2.77733674 0.58315357 238.75 -4.71688585e-01 3.95700630e-01 6.15685886e-01 2.44357677 0.50506594 239.00 -3.60984255e-01 3.99272910e-01 5.38264330e-01 2.30587424 0.44679796 239.25 -2.82743428e-01 3.25953468e-01 4.31496824e-01 2.28532560 0.51350506 239.50 -2.42652004e-01 3.07307632e-01 3.91558394e-01 2.23916736 0.49094454 239.75 -2.66246278e-01 3.77813131e-01 4.62201085e-01 2.18467211 0.57395941 240.00 -2.73559029e-01 3.47292437e-01 4.42093406e-01 2.23798641 0.47566274 240.25 -3.61616770e-01 4.12149271e-01 5.48300748e-01 2.29097989 0.57611133 240.50 -3.59356337e-01 4.06380545e-01 5.42477764e-01 2.29486111 0.54968491 240.75 -3.51435248e-01 4.91993855e-01 6.04619456e-01 2.19106071 0.58482489 241.00 -1.23724748e-01 4.63694553e-01 4.79917130e-01 1.83154542 0.45149182 241.25 6.27627502e-02 5.20163647e-01 5.23936429e-01 1.45071719 0.51997931 241.50 1.78566013e-01 4.36882066e-01 4.71965847e-01 1.18278837 0.50190059 241.75 2.82119160e-01 3.24040162e-01 4.29643163e-01 0.85444661 0.58801322 242.00 3.23694836e-01 2.99727125e-01 4.41151557e-01 0.74697168 0.61681599 242.25 3.21190911e-01 2.74543646e-01 4.22537354e-01 0.70725551 0.67485683 242.50 3.27113697e-01 2.30818149e-01 4.00350333e-01 0.61448820 0.72081321 242.75 3.36382875e-01 1.89501787e-01 3.86088547e-01 0.51303604 0.70060137 243.00 4.25212344e-01 8.84498545e-02 4.34314303e-01 0.20508872 0.68531795 243.25 5.13013695e-01 5.26926652e-02 5.15712680e-01 0.10235308 0.71667551 243.50 5.22572190e-01 -7.52452078e-02 5.27961680e-01 -0.14300715 0.42074991 243.75 5.33507905e-01 -2.13021774e-01 5.74464064e-01 -0.37988996 0.32045593 244.00 -9.69701600e-02 -2.59738085e-01 2.77249138e-01 -1.92810932 0.08034969 244.25 -2.38047221e-01 -1.78730182e-01 2.97675927e-01 -2.49756811 0.09413607 244.50 -3.14251486e-01 -5.25762010e-02 3.18619292e-01 -2.97582186 0.13088178 244.75 -2.96613386e-01 -1.11330145e-01 3.16818405e-01 -2.78252607 0.17423895 245.00 -3.85961438e-01 5.15375367e-02 3.89387146e-01 3.00884763 0.25773076 245.25 -4.79863790e-01 3.75199058e-02 4.81328370e-01 3.06356275 0.37175834 245.50 -6.23760902e-01 1.65369681e-01 6.45309843e-01 2.88243751 0.48061678 245.75 -5.80356862e-01 2.39171318e-01 6.27707740e-01 2.75068974 0.45214182 246.00 -5.41051894e-01 3.77476710e-01 6.59716468e-01 2.53243087 0.46421687 246.25 -5.25220782e-01 3.40152327e-01 6.25747933e-01 2.56688050 0.49382077 246.50 -3.87544077e-01 4.26881957e-01 5.76557557e-01 2.30793065 0.52941256 246.75 -2.83566423e-01 4.34919621e-01 5.19196488e-01 2.14857435 0.47316623 247.00 -1.42311843e-01 4.91127995e-01 5.11330977e-01 1.85283723 0.52410586 247.25 -8.50672904e-02 3.79512837e-01 3.88929862e-01 1.79130030 0.35618930 247.50 -1.03273493e-01 3.35893135e-01 3.51410889e-01 1.86908246 0.39118044 247.75 -4.87294461e-02 3.10187576e-01 3.13991865e-01 1.72661949 0.40174742 248.00 -1.38469368e-02 2.78537647e-01 2.78881621e-01 1.62046842 0.52611446 248.25 -5.89055211e-02 2.56751259e-01 2.63421847e-01 1.79631988 0.50677182 248.50 -8.96799572e-02 2.12870863e-01 2.30990258e-01 1.96951875 0.49977217 248.75 -1.18317481e-01 1.88284957e-01 2.22374125e-01 2.13183386 0.41628273 249.00 -1.35837526e-01 1.77680746e-01 2.23656614e-01 2.22351515 0.41644234 249.25 -1.67957892e-01 1.30791636e-01 2.12876268e-01 2.47996465 0.24878051 249.50 -2.56856369e-01 2.84547643e-02 2.58427684e-01 3.03126169 0.26171333 249.75 -3.26353513e-01 4.93169832e-01 5.91373908e-01 2.15538507 0.06686980 250.00 -6.56683568e-01 1.66265867e+00 1.78764291e+00 1.94695029 0.12417209 250.25 -3.60496717e-01 8.57372329e-01 9.30078058e-01 1.96882117 0.07372764 250.50 -9.68889851e-02 -2.87495001e-01 3.03382351e-01 -1.89585314 0.11643243 250.75 4.84884918e-02 -2.22270436e-01 2.27497870e-01 -1.35601046 0.09730982 251.00 1.06196599e-01 -2.20843520e-01 2.45050154e-01 -1.12257106 0.11218417 251.25 2.24284555e-01 -1.35016726e-01 2.61788231e-01 -0.54188036 0.16321502 251.50 3.37488158e-01 -3.12535825e-02 3.38932210e-01 -0.09234308 0.34579730 251.75 3.76985626e-01 8.94145443e-02 3.87444348e-01 0.23287961 0.39949671 252.00 4.10948519e-01 1.46098311e-01 4.36146078e-01 0.34157937 0.47941209 252.25 3.89401034e-01 1.53673514e-01 4.18627178e-01 0.37587781 0.52485385 252.50 4.11030030e-01 1.79115007e-01 4.48361318e-01 0.41095838 0.66535362 252.75 4.10935259e-01 1.55995013e-01 4.39547757e-01 0.36280592 0.62487631 253.00 4.16201440e-01 1.66180304e-01 4.48151238e-01 0.37988428 0.65467926 253.25 3.28643481e-01 1.78430740e-01 3.73957306e-01 0.49739977 0.53512950 253.50 3.42710149e-01 2.30061142e-01 4.12769155e-01 0.59120308 0.59447791 253.75 4.37246361e-01 2.07157517e-01 4.83837387e-01 0.44245047 0.68150211 254.00 4.92109558e-01 1.71010476e-01 5.20976391e-01 0.33445027 0.75186667 254.25 4.84263289e-01 3.84208990e-02 4.85785033e-01 0.07917302 0.75617592 254.50 4.89002534e-01 1.98451911e-02 4.89405057e-01 0.04056074 0.76374609 254.75 4.31439323e-01 1.57071765e-01 4.59142057e-01 0.34914914 0.67236853 255.00 4.56958680e-01 1.94806766e-01 4.96750351e-01 0.40298102 0.71916049 255.25 6.13486066e-01 1.28254668e-01 6.26749083e-01 0.20609059 0.73052809 255.50 6.42614765e-01 -1.62350841e-03 6.42616816e-01 -0.00252640 0.66791880 255.75 5.89862846e-01 -2.30817028e-01 6.33415090e-01 -0.37298939 0.72260135 256.00 5.45523010e-01 -2.66206869e-01 6.07010257e-01 -0.45398923 0.72685392 256.25 4.34850249e-01 -2.75510286e-01 5.14782145e-01 -0.56474192 0.77515718 256.50 3.70808699e-01 -2.98010778e-01 4.75719996e-01 -0.67697958 0.75785369 256.75 3.10309977e-01 -2.33712492e-01 3.88476268e-01 -0.64551927 0.68541819 257.00 2.93453733e-01 -2.24918455e-01 3.69734235e-01 -0.65394806 0.62300364 257.25 2.20230664e-01 -2.63533090e-01 3.43440293e-01 -0.87467175 0.70087744 257.50 2.10130956e-01 -2.46657820e-01 3.24029473e-01 -0.86519283 0.64483792 257.75 2.35647576e-01 -1.90266740e-01 3.02871611e-01 -0.67924943 0.70563654 258.00 2.15376791e-01 -1.84263089e-01 2.83443201e-01 -0.70770055 0.64580976 258.25 1.74105247e-01 -1.72092584e-01 2.44802971e-01 -0.77958461 0.64297270 258.50 1.64177120e-01 -1.48686578e-01 2.21499041e-01 -0.73592645 0.55258098 258.75 1.40803454e-01 -1.12694900e-01 1.80348976e-01 -0.67496668 0.59109836 259.00 1.39614340e-01 -1.01033724e-01 1.72336814e-01 -0.62643124 0.48857510 259.25 1.25846965e-01 -2.90254683e-02 1.29150829e-01 -0.22667708 0.42070461 259.50 1.53228175e-01 2.58429322e-02 1.55392184e-01 0.16708413 0.39898721 259.75 2.61571209e-01 1.28969980e-01 2.91638052e-01 0.45807923 0.70638653 260.00 3.31109006e-01 1.11131569e-01 3.49261220e-01 0.32382007 0.77033476 260.25 3.98949871e-01 8.69592226e-02 4.08317164e-01 0.21461348 0.83600031 260.50 4.75043103e-01 6.12202608e-02 4.78971680e-01 0.12816664 0.76150727 260.75 5.56743578e-01 -1.64036395e-05 5.56743578e-01 -0.00002946 0.81408633 261.00 5.39097965e-01 -9.83193026e-02 5.47990238e-01 -0.18039480 0.81553998 261.25 5.50632119e-01 -1.39687727e-01 5.68074283e-01 -0.24844493 0.88705596 261.50 5.55527116e-01 -1.77724322e-01 5.83263501e-01 -0.30963052 0.86365114 261.75 5.74934567e-01 -1.89506866e-01 6.05361552e-01 -0.31840003 0.89287378 262.00 6.04597181e-01 -1.87233297e-01 6.32925002e-01 -0.30031618 0.82936224 262.25 6.24528835e-01 -2.18709645e-01 6.61717594e-01 -0.33685248 0.82917580 262.50 5.98763147e-01 -2.56755559e-01 6.51491153e-01 -0.40509323 0.70653818 262.75 6.54014154e-01 -2.95392924e-01 7.17629078e-01 -0.42423466 0.66303330 263.00 6.78992042e-01 -3.15276944e-01 7.48618557e-01 -0.43470734 0.59795298 263.25 6.62476092e-01 -4.30140031e-01 7.89870254e-01 -0.57587692 0.61461423 263.50 6.16020097e-01 -4.48205843e-01 7.61819688e-01 -0.62899929 0.50938807 263.75 5.35886765e-01 -6.14809671e-01 8.15576824e-01 -0.85387799 0.48428803 264.00 1.37328601e-01 -5.24332198e-01 5.42017895e-01 -1.31463869 0.16513323 264.25 -2.72024763e-02 -6.15383509e-01 6.15984446e-01 -1.61497167 0.16860510 264.50 6.42371431e-02 -6.49113025e-01 6.52283780e-01 -1.47215608 0.16028664 264.75 1.07719594e-01 -4.98108802e-01 5.09623282e-01 -1.35781886 0.06488307 265.00 -3.06133699e-01 -2.79647799e-01 4.14633252e-01 -2.40137836 0.02685793 265.25 -3.22201836e-01 -4.59044100e-02 3.25455431e-01 -3.00007406 0.01785321 265.50 -5.67242514e-01 1.72723498e-01 5.92956555e-01 2.84601553 0.09921292 265.75 -6.08661127e-01 -9.76812526e-02 6.16449507e-01 -2.98246410 0.17636062 266.00 -4.37177003e-01 1.91020814e-02 4.37594128e-01 3.09792627 0.19426003 266.25 -4.71111363e-01 8.27040869e-02 4.78315673e-01 2.96781238 0.29566855 266.50 -2.56601363e-01 1.37896686e-01 2.91306978e-01 2.64847727 0.26574419 266.75 -1.77804187e-01 7.93775269e-02 1.94718054e-01 2.72170961 0.21725473 267.00 -6.24634860e-02 -4.25750954e-02 7.55931599e-02 -2.54332290 0.06293514 267.25 -4.46302663e-02 -6.35336662e-02 7.76426907e-02 -2.18317568 0.06451260 267.50 -3.51168306e-02 -1.03893776e-01 1.09668175e-01 -1.89674733 0.11420445 267.75 -2.54524468e-02 -1.18947350e-01 1.21640039e-01 -1.78159810 0.14899093 268.00 -7.64783297e-02 -1.19936877e-01 1.42245525e-01 -2.13844404 0.19265556 268.25 -6.72667114e-02 -1.36449081e-01 1.52128768e-01 -2.02881244 0.21008756 268.50 -2.07681804e-02 -1.61113952e-01 1.62446984e-01 -1.69899307 0.30808347 268.75 -3.29606903e-02 -1.39777511e-01 1.43611141e-01 -1.80237410 0.19642981 269.00 -8.26216898e-02 -1.17939445e-01 1.44000195e-01 -2.18188684 0.30306459 269.25 -6.69459264e-02 -1.12773599e-01 1.31147405e-01 -2.10651972 0.31390545 269.50 -6.67867313e-02 -1.08513679e-01 1.27419332e-01 -2.12251202 0.34659810 269.75 -5.55239607e-02 -1.15245857e-01 1.27923875e-01 -2.01976770 0.23505031 270.00 -8.65843544e-03 -1.43063002e-01 1.43324775e-01 -1.63124443 0.27882623 270.25 -5.76055660e-03 -1.09319290e-01 1.09470960e-01 -1.62344242 0.13902875 270.50 -6.58960364e-03 -7.31220624e-02 7.34183825e-02 -1.66067141 0.07801163 270.75 1.65568498e-02 -5.41202032e-02 5.65961630e-02 -1.27391052 0.03982983 271.00 5.40933006e-02 -9.57118052e-02 1.09940142e-01 -1.05638204 0.15491525 271.25 5.66262434e-02 -8.92024073e-02 1.05657943e-01 -1.00517640 0.13481447 271.50 5.23508047e-02 -7.89887040e-02 9.47619233e-02 -0.98550101 0.14380843 271.75 8.95910765e-02 -1.08779981e-01 1.40924254e-01 -0.88183051 0.17645291 272.00 1.29252924e-01 -1.25872842e-01 1.80416991e-01 -0.77215025 0.34602949 272.25 9.45902819e-02 -1.16418715e-01 1.50002128e-01 -0.88847938 0.21909743 272.50 1.21751982e-01 -1.12350698e-01 1.65669021e-01 -0.74526093 0.27143374 272.75 1.13373113e-01 -7.31600095e-02 1.34929055e-01 -0.57306619 0.15475101 273.00 1.39542325e-01 -4.48286687e-02 1.46566265e-01 -0.31084095 0.18949181 273.25 1.15702798e-01 -3.60955106e-02 1.21202407e-01 -0.30239965 0.13252909 273.50 1.21647914e-01 -6.29635966e-02 1.36976748e-01 -0.47761943 0.16442762 273.75 1.21083908e-01 8.47462575e-03 1.21380114e-01 0.06987575 0.08243955 274.00 1.45618433e-01 4.19350948e-02 1.51536399e-01 0.28039248 0.14384432 274.25 1.53926670e-01 3.74459204e-02 1.58415961e-01 0.23863568 0.15149654 274.50 1.71627866e-01 6.07812417e-02 1.82072743e-01 0.34036316 0.14941701 274.75 1.76153848e-01 1.12418364e-01 2.08969057e-01 0.56802300 0.18989112 275.00 1.77886934e-01 1.70284159e-01 2.46252830e-01 0.76356531 0.24669126 275.25 8.84612265e-02 1.77753266e-01 1.98548766e-01 1.10902005 0.15234991 275.50 2.96671581e-02 2.34747195e-01 2.36614424e-01 1.44508360 0.14844351 275.75 -5.27333562e-02 3.37656997e-01 3.41749988e-01 1.72571920 0.04913338 276.00 -1.16718007e-01 3.61907204e-01 3.80262958e-01 1.88277274 0.03847042 276.25 -6.07088779e-02 2.39790498e-01 2.47356121e-01 1.81876067 0.07237200 276.50 -1.67789032e-01 1.84526173e-01 2.49405429e-01 2.30872402 0.16009137 276.75 -2.23277171e-01 6.90276841e-02 2.33703908e-01 2.84175632 0.16000822 277.00 -2.32666429e-01 2.79713569e-02 2.34341768e-01 3.02194601 0.17074574 277.25 -3.02567993e-01 1.50936454e-01 3.38126017e-01 2.67886438 0.22991599 277.50 -3.05081486e-01 1.39628615e-01 3.35515817e-01 2.71237335 0.22424068 277.75 -4.14646194e-01 6.98809788e-02 4.20493541e-01 2.97463002 0.33332321 278.00 -3.86172212e-01 7.45326623e-02 3.93298990e-01 2.95093328 0.31502773 278.25 -4.06498656e-01 6.36419430e-02 4.11450428e-01 2.98629208 0.44419116 278.50 -3.56198689e-01 7.40418811e-02 3.63812735e-01 2.93664443 0.42579216 278.75 -2.81117988e-01 2.82881433e-02 2.82537682e-01 3.04130295 0.33416188 279.00 -2.82405849e-01 -2.32776435e-02 2.83363569e-01 -3.05935236 0.32968653 279.25 -3.50236388e-01 -9.00877687e-02 3.61637019e-01 -2.88983042 0.56810964 279.50 -2.96183196e-01 -1.72790863e-01 3.42901106e-01 -2.61347455 0.49819911 279.75 -2.50096852e-01 -2.83092728e-01 3.77743204e-01 -2.29438936 0.58722198 280.00 -2.26097194e-01 -2.65677602e-01 3.48861762e-01 -2.27588278 0.48011484 280.25 -2.29074265e-01 -3.26305997e-01 3.98686120e-01 -2.18287862 0.51693270 280.50 -1.65056441e-01 -3.32447096e-01 3.71166675e-01 -2.03163147 0.43777970 280.75 -1.67265504e-01 -4.44063865e-01 4.74521301e-01 -1.93103024 0.52036176 281.00 -1.37865494e-01 -4.57406783e-01 4.77731996e-01 -1.86354322 0.36891242 281.25 -1.83940592e-01 -4.95783701e-01 5.28805843e-01 -1.92606412 0.33350623 281.50 -1.67662098e-01 -3.85269359e-01 4.20170273e-01 -1.98125909 0.22924637 281.75 -1.23851042e-01 -4.34355915e-01 4.51668176e-01 -1.84856240 0.24723258 282.00 -1.05684960e-01 -2.63833603e-01 2.84213794e-01 -1.95179769 0.07336373 282.25 -2.36968585e-01 -1.51821425e-01 2.81431795e-01 -2.57179603 0.05070501 282.50 -1.30658934e-01 5.01626238e-02 1.39957300e-01 2.77502443 0.01735988 282.75 -1.59193421e-01 2.16469987e-01 2.68703927e-01 2.20489195 0.06672189 283.00 -1.58260183e-01 2.26839178e-01 2.76590488e-01 2.17996065 0.08911385 283.25 -1.01237728e-01 3.10336991e-01 3.26432421e-01 1.88613010 0.14907250 283.50 -1.73192863e-01 2.63207507e-01 3.15077704e-01 2.15278107 0.24741476 283.75 -1.72268213e-01 2.60048127e-01 3.11931668e-01 2.15587223 0.34768526 284.00 -1.72375361e-01 1.74577173e-01 2.45337430e-01 2.34984843 0.25809508 284.25 -1.79443799e-01 1.00571557e-01 2.05705408e-01 2.63075216 0.22888238 284.50 -2.34907384e-01 -1.62221867e-02 2.35466852e-01 -3.07264432 0.24743823 284.75 -2.95365307e-01 -2.77128368e-02 2.96662546e-01 -3.04804090 0.34372289 285.00 -3.44285019e-01 7.77632956e-02 3.52957935e-01 2.91945129 0.48687215 285.25 -3.19745904e-01 1.11644757e-01 3.38676829e-01 2.80566001 0.57372120 285.50 -3.65838458e-01 1.34327936e-01 3.89720120e-01 2.78969695 0.68027997 285.75 -3.84973178e-01 1.17175581e-01 4.02410815e-01 2.84612844 0.71492697 286.00 -3.58446746e-01 1.37088825e-01 3.83767398e-01 2.77630442 0.75405804 286.25 -3.50712784e-01 1.30978830e-01 3.74372689e-01 2.78416872 0.76720561 286.50 -3.81480999e-01 1.32702020e-01 4.03902932e-01 2.80682547 0.79330329 286.75 -3.63549389e-01 1.35662022e-01 3.88036522e-01 2.78443627 0.77609522 287.00 -2.86229736e-01 2.02874413e-01 3.50835416e-01 2.52499718 0.68619135 287.25 -2.43717697e-01 2.02659626e-01 3.16968831e-01 2.44791704 0.62291250 287.50 -1.95197087e-01 2.49515214e-01 3.16796061e-01 2.23465434 0.68049639 287.75 -1.19243473e-01 2.11935975e-01 2.43178665e-01 2.08329147 0.53571512 288.00 -1.78956569e-02 1.32816292e-01 1.34016499e-01 1.70472962 0.40786008 288.25 -2.14473298e-02 9.20824704e-02 9.45471803e-02 1.79963088 0.22072769 288.50 -5.82175768e-02 -1.20873429e-03 5.82301235e-02 -3.12083328 0.11909432 288.75 -7.05046651e-02 -3.18946250e-02 7.73832987e-02 -2.71676452 0.16702985 289.00 -7.63702482e-02 -4.30936558e-02 8.76896686e-02 -2.62785750 0.25125456 289.25 -9.96631247e-02 -4.58443348e-02 1.09701602e-01 -2.71045973 0.33306453 289.50 -1.37201476e-01 -3.99253689e-02 1.42892547e-01 -2.85841481 0.44203864 289.75 -1.62132281e-01 -4.49776552e-02 1.68255359e-01 -2.87098418 0.52142241 290.00 -1.76783871e-01 -5.02534767e-02 1.83787783e-01 -2.86463336 0.63975551 290.25 -1.79886681e-01 -3.40669357e-02 1.83084063e-01 -2.95442919 0.62657455 290.50 -1.72245022e-01 -4.47846146e-03 1.72303233e-01 -3.11559798 0.66280892 290.75 -1.60248370e-01 1.38464071e-02 1.60845464e-01 3.05540082 0.53051769 291.00 -1.42582787e-01 2.52780710e-02 1.44806188e-01 2.96612883 0.55443582 291.25 -1.29898635e-01 1.51439335e-02 1.30778416e-01 3.02553387 0.39374972 291.50 -1.11651832e-01 -2.80735455e-02 1.15127128e-01 -2.89526077 0.48498246 291.75 -9.16385728e-02 -2.47380926e-02 9.49189193e-02 -2.87792478 0.32510458 292.00 -8.22247844e-02 -3.74593871e-02 9.03555248e-02 -2.71411394 0.33559734 292.25 -8.52494954e-02 -4.62635628e-02 9.69937818e-02 -2.64438345 0.35335969 292.50 -9.99046060e-02 -7.59801146e-02 1.25514573e-01 -2.49138846 0.48706786 292.75 -6.59815466e-02 -1.44219390e-01 1.58596334e-01 -1.99987646 0.33220866 293.00 -8.89462997e-03 -2.43684191e-01 2.43846467e-01 -1.60728077 0.52536666 293.25 8.91872638e-02 -2.35852404e-01 2.52152185e-01 -1.20926807 0.35348715 293.50 1.83678020e-01 -2.16478554e-01 2.83902412e-01 -0.86718457 0.39891027 293.75 2.40492697e-01 -1.33067897e-01 2.74852329e-01 -0.50538374 0.35898944 294.00 2.85172230e-01 -1.08137447e-01 3.04986735e-01 -0.36244819 0.48213073 294.25 2.23104632e-01 -2.73653337e-02 2.24776641e-01 -0.12204733 0.37528886 294.50 1.79015596e-01 -4.17217574e-02 1.83813190e-01 -0.22897472 0.34851048 294.75 2.08979280e-01 -3.88549261e-02 2.12560685e-01 -0.18382810 0.51282688 295.00 2.24585348e-01 -2.30450336e-02 2.25764594e-01 -0.10225360 0.59814586 295.25 1.90428653e-01 -1.75162546e-02 1.91232558e-01 -0.09172518 0.49178231 295.50 1.85341695e-01 -3.22426602e-02 1.88125312e-01 -0.17223963 0.54624744 295.75 1.85669068e-01 -4.62016150e-02 1.91331106e-01 -0.24388520 0.65543696 296.00 1.92978626e-01 -5.92565867e-02 2.01871477e-01 -0.29792391 0.70488797 296.25 1.94099419e-01 -7.23746077e-02 2.07153731e-01 -0.35690539 0.70050228 296.50 1.82935375e-01 -7.06361729e-02 1.96099006e-01 -0.36848944 0.70651083 296.75 1.84284439e-01 -8.66699993e-02 2.03647842e-01 -0.43961114 0.75868889 297.00 1.81594587e-01 -9.10994409e-02 2.03164225e-01 -0.46497781 0.78539827 297.25 1.72623186e-01 -6.94651127e-02 1.86075700e-01 -0.38258132 0.77554359 297.50 1.69437187e-01 -6.35399518e-02 1.80959349e-01 -0.35877588 0.77083658 297.75 1.45262988e-01 -6.51627582e-02 1.59209048e-01 -0.42167636 0.75109039 298.00 1.54474453e-01 -5.88640521e-02 1.65309810e-01 -0.36407303 0.76686620 298.25 1.49675207e-01 -4.45713753e-02 1.56170661e-01 -0.28942556 0.78541088 298.50 1.45057527e-01 -2.83854498e-02 1.47808727e-01 -0.19324222 0.74239712 298.75 1.57671000e-01 -3.13718613e-02 1.60761742e-01 -0.19640536 0.84895114 299.00 1.54654372e-01 -1.82610509e-02 1.55728741e-01 -0.11753233 0.83159316 299.25 1.64176242e-01 1.91905722e-03 1.64187458e-01 0.01168847 0.88389903 299.50 1.68173638e-01 8.53118001e-03 1.68389886e-01 0.05068496 0.86731238 299.75 1.69096820e-01 2.41021306e-02 1.70805875e-01 0.14158085 0.87153711 300.00 1.79823306e-01 2.97030138e-02 1.82259953e-01 0.16370076 0.85191662 300.25 1.87343868e-01 4.29105733e-02 1.92195323e-01 0.22516319 0.88110329 300.50 2.02125249e-01 3.66850498e-02 2.05427382e-01 0.17954221 0.86529450 300.75 2.18302788e-01 3.17515527e-02 2.20599792e-01 0.14443449 0.89247737 301.00 2.16353109e-01 2.46190412e-02 2.17749317e-01 0.11330366 0.88523964 301.25 2.20186619e-01 1.41191541e-02 2.20638840e-01 0.06403591 0.89938745 301.50 2.10902812e-01 1.67582195e-02 2.11567563e-01 0.07929284 0.86701429 301.75 2.13619993e-01 2.19498457e-02 2.14744725e-01 0.10239249 0.87826888 302.00 2.16418888e-01 2.62150616e-02 2.18000836e-01 0.12054384 0.87154130 302.25 2.16748659e-01 3.24790257e-02 2.19168584e-01 0.14873981 0.90793439 302.50 2.19521922e-01 2.68049354e-02 2.21152388e-01 0.12150447 0.88164586 302.75 2.30114242e-01 2.31873132e-02 2.31279518e-01 0.10042538 0.90446438 303.00 2.24336252e-01 1.75018879e-02 2.25017933e-01 0.07785861 0.87441568 303.25 2.20197239e-01 1.87214565e-02 2.20991667e-01 0.08481733 0.88363424 303.50 2.04887528e-01 3.50856101e-03 2.04917566e-01 0.01712265 0.84549971 303.75 2.03467133e-01 -2.44941201e-03 2.03481876e-01 -0.01203779 0.92695519 304.00 2.10234380e-01 4.62531626e-03 2.10285254e-01 0.02199721 0.86842353 304.25 1.99696173e-01 -1.39870339e-02 2.00185411e-01 -0.06992737 0.83387867 304.50 1.89402518e-01 -2.54286761e-02 1.91101888e-01 -0.13345928 0.82054490 304.75 1.78592916e-01 -3.25233395e-02 1.81530156e-01 -0.18013479 0.79970906 305.00 1.33594631e-01 -4.60340106e-02 1.41303416e-01 -0.33183799 0.69811739 305.25 1.14155274e-01 -4.19927985e-02 1.21633966e-01 -0.35249351 0.73734283 305.50 9.20022890e-02 -3.23928755e-02 9.75382980e-02 -0.33853349 0.64742869 305.75 8.56268671e-02 -1.82713457e-02 8.75545684e-02 -0.21023040 0.64429171 306.00 7.00485319e-02 2.52471747e-03 7.00940156e-02 0.03602681 0.52845001 306.25 6.48406003e-02 5.08626211e-03 6.50397841e-02 0.07828225 0.55683604 306.50 5.69973654e-02 1.09934256e-02 5.80478688e-02 0.19053630 0.41774543 306.75 4.98729533e-02 9.53270493e-03 5.07758203e-02 0.18886178 0.34536968 307.00 3.70846598e-02 2.90019287e-02 4.70784862e-02 0.66369742 0.21220397 307.25 2.98996324e-02 3.67704160e-02 4.73925259e-02 0.88809215 0.19333277 307.50 4.31624202e-02 3.57128385e-02 5.60214365e-02 0.69122987 0.20054801 307.75 3.88941935e-02 2.90903478e-02 4.85696060e-02 0.64217851 0.14880697 308.00 4.16135301e-02 -2.48337062e-02 4.84602812e-02 -0.53804111 0.06587093 308.25 -1.63622024e-02 -1.51594362e-02 2.23053844e-02 -2.39433283 0.00755573 308.50 -8.56112097e-02 7.45130948e-02 1.13496610e-01 2.42539320 0.19727344 308.75 -8.06132896e-02 1.16726808e-01 1.41857852e-01 2.17519585 0.38393598 309.00 -4.74501548e-02 1.73849189e-01 1.80208373e-01 1.83724507 0.67571172 309.25 -2.13986963e-02 1.54859113e-01 1.56330576e-01 1.70810848 0.55818675 309.50 1.99879926e-02 1.21088054e-01 1.22726674e-01 1.40720166 0.50504822 309.75 2.49020673e-02 1.11326982e-01 1.14078087e-01 1.35073480 0.45431742 310.00 5.62121646e-02 6.28225529e-02 8.42999442e-02 0.84087446 0.37353411 310.25 4.88505997e-02 4.01610450e-02 6.32399449e-02 0.68808385 0.23340890 310.50 1.75398691e-02 1.17675467e-02 2.11216042e-02 0.59092956 0.02825838 310.75 -3.32999319e-02 -3.60092788e-02 4.90464435e-02 -2.31712366 0.13014636 311.00 -7.94602410e-02 -7.36472328e-02 1.08341335e-01 -2.39414311 0.58415368 311.25 -1.48469456e-01 -5.18916138e-02 1.57276568e-01 -2.80535410 0.66421057 311.50 -2.42356076e-01 -2.23481621e-02 2.43384280e-01 -3.04964059 0.85142593 311.75 -2.72249581e-01 3.39201710e-02 2.74354538e-01 3.01763922 0.82163824 312.00 -3.26762397e-01 1.06135785e-01 3.43567270e-01 2.82753236 0.88575086 312.25 -3.02314600e-01 2.07211522e-01 3.66511572e-01 2.54072123 0.84882875 312.50 -2.78629955e-01 2.96319677e-01 4.06743166e-01 2.32543676 0.91984736 312.75 -2.08047646e-01 3.11722577e-01 3.74772981e-01 2.15931532 0.91239356 313.00 -1.87001861e-01 3.30818038e-01 3.80013513e-01 2.08528831 0.94946144 313.25 -1.95916884e-01 3.75306028e-01 4.23365138e-01 2.05190358 0.94363263 313.50 -1.90125507e-01 4.18892382e-01 4.60020148e-01 1.99686947 0.96661514 313.75 -1.14218901e-01 4.82505722e-01 4.95840427e-01 1.80323793 0.94837560 314.00 -3.25193197e-02 5.21995000e-01 5.23006966e-01 1.63301406 0.96408411 314.25 6.63403733e-02 5.10135380e-01 5.14430900e-01 1.44147742 0.93267660 314.50 1.46940461e-01 4.78622323e-01 5.00670377e-01 1.27292344 0.92761973 314.75 2.53077920e-01 3.80953997e-01 4.57355859e-01 0.98441543 0.76065684 315.00 3.45978805e-01 2.40024524e-01 4.21085627e-01 0.60652238 0.78661045 315.25 3.23660501e-01 1.09190860e-01 3.41582734e-01 0.32537225 0.74772827 315.50 3.07803168e-01 1.13372591e-02 3.08011889e-01 0.03681618 0.75622568 315.75 2.17884717e-01 -8.19369399e-02 2.32781898e-01 -0.35969650 0.72878747 316.00 1.65340345e-01 -1.06925450e-01 1.96902214e-01 -0.57405122 0.74059654 316.25 9.30684805e-02 -1.35835899e-01 1.64660662e-01 -0.97010391 0.78555509 316.50 5.26909690e-02 -1.35648359e-01 1.45522560e-01 -1.20029681 0.77984443 316.75 -2.17388716e-02 -9.97114204e-02 1.02053642e-01 -1.78545522 0.71511480 317.00 -4.70968971e-02 -8.06573043e-02 9.34008482e-02 -2.09930361 0.73567508 317.25 -7.10693214e-02 -5.21081032e-02 8.81254949e-02 -2.50892983 0.74557976 317.50 -7.78077909e-02 -3.72673519e-02 8.62722890e-02 -2.69491271 0.78804050 317.75 -6.77778836e-02 -2.38818517e-02 7.18622595e-02 -2.80282170 0.76631133 318.00 -7.11556037e-02 -2.20283450e-02 7.44873675e-02 -2.84137029 0.78211942 318.25 -8.41321702e-02 -2.31506608e-02 8.72592411e-02 -2.87306827 0.85079017 318.50 -8.78855635e-02 -2.14468135e-02 9.04645681e-02 -2.90223959 0.82854053 318.75 -8.97018403e-02 -2.29012677e-02 9.25790917e-02 -2.89162795 0.84926338 319.00 -9.43965351e-02 -2.31534545e-02 9.71945898e-02 -2.90106253 0.83841058 319.25 -9.77439029e-02 -2.88742866e-02 1.01919552e-01 -2.85435443 0.83683607 319.50 -1.01441023e-01 -3.41756023e-02 1.07043229e-01 -2.81663446 0.83637734 319.75 -1.05428377e-01 -3.70251120e-02 1.11740779e-01 -2.80386046 0.82128112 320.00 -1.05693925e-01 -4.98538359e-02 1.16861502e-01 -2.70085565 0.76505461 320.25 -1.27866737e-01 -7.40278788e-02 1.47749888e-01 -2.61679824 0.86226422 320.50 -1.47544343e-01 -8.88208337e-02 1.72216357e-01 -2.59970814 0.83408569 320.75 -2.07581510e-01 -1.19922970e-01 2.39732355e-01 -2.61772031 0.89346050 321.00 -2.41858382e-01 -8.61386640e-02 2.56739842e-01 -2.79944659 0.88272775 321.25 -2.60563995e-01 -4.37713725e-02 2.64214929e-01 -2.97515957 0.91546878 321.50 -2.59159335e-01 -2.50968823e-02 2.60371685e-01 -3.04505409 0.90374018 321.75 -2.68588830e-01 -2.32866028e-02 2.69596412e-01 -3.05510910 0.94083740 322.00 -2.83022341e-01 -1.77883241e-02 2.83580800e-01 -3.07882391 0.92339689 322.25 -3.10922076e-01 -1.94620844e-02 3.11530593e-01 -3.07907948 0.94572345 322.50 -3.23112573e-01 -1.30169064e-03 3.23115195e-01 -3.13756408 0.93390317 322.75 -3.39856188e-01 1.73786242e-02 3.40300228e-01 3.09050192 0.95857336 323.00 -3.54204204e-01 3.85183938e-02 3.56292415e-01 3.03327201 0.94398681 323.25 -3.64677687e-01 7.07245278e-02 3.71472441e-01 2.95003356 0.95163330 323.50 -3.61441936e-01 8.14360460e-02 3.70502500e-01 2.91998432 0.94205689 323.75 -3.71315742e-01 9.04876404e-02 3.82182408e-01 2.90255723 0.95775536 324.00 -3.75864343e-01 1.15530983e-01 3.93219293e-01 2.84338439 0.93498582 324.25 -3.84043267e-01 1.23703199e-01 4.03474550e-01 2.82997918 0.94124179 324.50 -4.42555432e-01 1.32416558e-01 4.61940965e-01 2.85086173 0.94644663 324.75 -4.66941383e-01 1.42636978e-01 4.88241296e-01 2.84512433 0.95584752 325.00 -4.94507497e-01 1.80048263e-01 5.26265182e-01 2.79241564 0.94154268 325.25 -5.41538174e-01 2.03632159e-01 5.78558251e-01 2.78192322 0.93915097 325.50 -6.03416673e-01 2.94415472e-01 6.71410568e-01 2.68766047 0.91392648 325.75 -6.34408484e-01 3.46905951e-01 7.23061452e-01 2.64119575 0.91888013 326.00 -6.93450012e-01 5.73633636e-01 8.99960259e-01 2.45047489 0.87661913 326.25 -7.42312138e-01 7.92346879e-01 1.08574439e+00 2.32360287 0.91589750 326.50 -6.49458961e-01 1.06930703e+00 1.25108532e+00 2.11661319 0.91979334 326.75 -4.79600717e-01 1.25034214e+00 1.33916852e+00 1.93706404 0.88876692 327.00 3.53555375e-01 1.35783567e+00 1.40311051e+00 1.31607090 0.83032683 327.25 6.96511479e-01 1.13837205e+00 1.33454830e+00 1.02171005 0.87103330 327.50 9.00516911e-01 6.15818821e-01 1.09094616e+00 0.59980486 0.89425973 327.75 8.40104596e-01 4.33398726e-01 9.45309573e-01 0.47627599 0.88236443 328.00 6.97105088e-01 1.27248042e-01 7.08623713e-01 0.18055002 0.84048704 328.25 5.97805589e-01 4.19967397e-02 5.99278941e-01 0.07013627 0.81581821 328.50 4.15240101e-01 -6.44044731e-02 4.20205042e-01 -0.15387568 0.80712705 328.75 3.47993523e-01 -8.21851255e-02 3.57566619e-01 -0.23191907 0.80394398 329.00 2.39414358e-01 -6.07629948e-02 2.47004810e-01 -0.24855047 0.68213592 329.25 2.00926333e-01 -5.71277968e-02 2.08889867e-01 -0.27701207 0.68493626 329.50 1.76496113e-01 -4.60969085e-02 1.82416564e-01 -0.25547119 0.80029348 329.75 1.65429894e-01 -4.51253029e-02 1.71474030e-01 -0.26629739 0.78340084 330.00 1.61264650e-01 -3.64236005e-02 1.65326846e-01 -0.22213502 0.81069142 330.25 1.39132832e-01 -3.97364670e-02 1.44695998e-01 -0.27819486 0.76155413 330.50 1.14072880e-01 -5.79870356e-02 1.27965301e-01 -0.47029195 0.79555584 330.75 9.81230283e-02 -5.24949801e-02 1.11282755e-01 -0.49124735 0.71895082 331.00 7.51657413e-02 -4.13001090e-02 8.57647228e-02 -0.50242384 0.56908759 331.25 6.08670637e-02 -4.06622746e-02 7.31998636e-02 -0.58896006 0.49051063 331.50 5.05493684e-02 -3.10125037e-02 5.93044183e-02 -0.55029358 0.56629200 331.75 4.77112643e-02 -2.25616466e-02 5.27768191e-02 -0.44171623 0.46311804 332.00 4.59860573e-02 -2.20839101e-02 5.10138859e-02 -0.44770735 0.57736554 332.25 3.90712480e-02 -2.05002929e-02 4.41228334e-02 -0.48320395 0.48977897 332.50 3.45906806e-02 -1.75542039e-02 3.87900149e-02 -0.46961657 0.48008954 332.75 2.94472886e-02 -1.33651061e-02 3.23383498e-02 -0.42606376 0.29844885 333.00 1.59858000e-02 -1.46922817e-02 2.17119539e-02 -0.74325887 0.16238850 333.25 1.07920025e-02 -4.24254977e-03 1.15959712e-02 -0.37456113 0.04707030 333.50 4.54292515e-03 6.03468569e-03 7.55351576e-03 0.92550417 0.02899192 333.75 9.87017490e-03 2.59696719e-02 2.77820844e-02 1.20759213 0.22214343 334.00 1.17897200e-02 4.14427680e-02 4.30871271e-02 1.29363636 0.48665260 334.25 1.54967946e-02 7.10183360e-02 7.26894401e-02 1.35595559 0.57876491 334.50 1.70102602e-02 1.02456328e-01 1.03858790e-01 1.40627253 0.74976817 334.75 4.92637782e-02 1.38390535e-01 1.46897447e-01 1.22880718 0.76590036 335.00 9.51955846e-02 1.71373297e-01 1.96038278e-01 1.06375045 0.85523467 335.25 1.95226901e-01 2.08695020e-01 2.85774657e-01 0.81872919 0.90400619 335.50 2.50229821e-01 1.99338035e-01 3.19922828e-01 0.67267646 0.93813412 335.75 3.40957088e-01 1.33176786e-01 3.66043430e-01 0.37237408 0.90117146 336.00 4.01454656e-01 6.01217228e-02 4.05931598e-01 0.14865491 0.94338945 336.25 4.07365363e-01 -4.50275300e-02 4.09846333e-01 -0.11008664 0.94534972 336.50 4.01332824e-01 -1.05622214e-01 4.14998900e-01 -0.25734309 0.95140200 336.75 3.15616930e-01 -1.72181295e-01 3.59528087e-01 -0.49941169 0.93313396 337.00 2.85244321e-01 -1.80759844e-01 3.37695786e-01 -0.56483234 0.95901210 337.25 2.53109033e-01 -1.66124170e-01 3.02756374e-01 -0.58081536 0.96186223 337.50 2.45448424e-01 -1.54145845e-01 2.89837662e-01 -0.56076608 0.97071108 337.75 2.48564441e-01 -1.40125595e-01 2.85340960e-01 -0.51333054 0.97800849 338.00 2.51862478e-01 -1.37043363e-01 2.86732612e-01 -0.49831746 0.98057563 338.25 2.50088932e-01 -1.42684272e-01 2.87929289e-01 -0.51847159 0.98486212 338.50 2.47304456e-01 -1.37719128e-01 2.83065455e-01 -0.50811070 0.98725804 338.75 2.54326393e-01 -1.25168494e-01 2.83459108e-01 -0.45735348 0.99027688 339.00 2.59217650e-01 -1.22011994e-01 2.86497324e-01 -0.43992854 0.98856047 339.25 2.51415624e-01 -1.16914766e-01 2.77270407e-01 -0.43527893 0.98548226 339.50 2.54363279e-01 -1.09921031e-01 2.77098016e-01 -0.40790432 0.98236247 339.75 2.62457409e-01 -9.37588167e-02 2.78701645e-01 -0.34310513 0.98383591 340.00 2.64845730e-01 -8.73466607e-02 2.78877572e-01 -0.31856903 0.97587723 340.25 2.63000756e-01 -6.10325888e-02 2.69989583e-01 -0.22802629 0.96843559 340.50 2.65368701e-01 -4.32011333e-02 2.68862205e-01 -0.16138090 0.94789494 340.75 2.72554065e-01 -4.46329737e-03 2.72590608e-01 -0.01637436 0.94968532 341.00 2.72526044e-01 9.94811739e-03 2.72707553e-01 0.03648716 0.94085590 341.25 2.77912163e-01 3.08588602e-02 2.79620170e-01 0.11058518 0.93466362 341.50 2.72395066e-01 4.91917001e-02 2.76801184e-01 0.17866392 0.89012084 341.75 2.76200380e-01 7.71049433e-02 2.86760915e-01 0.27223244 0.88907482 342.00 2.66754947e-01 1.08366335e-01 2.87926144e-01 0.38587346 0.84696145 342.25 2.91254380e-01 1.63517651e-01 3.34016671e-01 0.51157289 0.88793477 342.50 3.16512846e-01 1.76558409e-01 3.62426894e-01 0.50883014 0.86237569 342.75 3.69468122e-01 1.49760143e-01 3.98666268e-01 0.38510118 0.87625426 343.00 3.16033419e-01 1.27619945e-01 3.40828362e-01 0.38379331 0.80942724 343.25 2.67945789e-01 1.24083473e-01 2.95282329e-01 0.43368750 0.86409244 343.50 2.43541064e-01 1.37117241e-01 2.79487723e-01 0.51278049 0.82895281 343.75 2.11315859e-01 1.49934232e-01 2.59103582e-01 0.61709111 0.87952516 344.00 1.80544193e-01 1.66835432e-01 2.45825684e-01 0.74595529 0.84545666 344.25 1.48963033e-01 1.92007321e-01 2.43016042e-01 0.91097444 0.90418136 344.50 1.05263809e-01 2.08437079e-01 2.33509069e-01 1.10314493 0.85743672 344.75 6.27968163e-02 2.27811835e-01 2.36308426e-01 1.30182394 0.86948324 345.00 4.20253668e-02 2.89717715e-01 2.92749869e-01 1.42674481 0.88341524 345.25 5.19659961e-02 3.40718786e-01 3.44658898e-01 1.41944399 0.89121229 345.50 1.51914906e-01 2.76031701e-01 3.15074021e-01 1.06768205 0.86960190 345.75 1.57089874e-01 2.24007641e-01 2.73599437e-01 0.95921842 0.90429076 346.00 7.65922356e-02 1.79737635e-01 1.95376529e-01 1.16796595 0.85434824 346.25 2.32668203e-02 1.69397508e-01 1.70987896e-01 1.43429996 0.86807120 346.50 -4.74801313e-02 1.60903937e-01 1.67763047e-01 1.85773669 0.75567021 346.75 -8.96264519e-02 1.69780912e-01 1.91985570e-01 2.05650990 0.85088353 347.00 -1.62941164e-01 2.01857828e-01 2.59415508e-01 2.24991670 0.84188003 347.25 -2.06634285e-01 2.15020431e-01 2.98213872e-01 2.33630845 0.86386104 347.50 -2.47426210e-01 2.87264335e-01 3.79131280e-01 2.28182502 0.85801497 347.75 -2.79292447e-01 3.26733148e-01 4.29835807e-01 2.27807213 0.87317552 348.00 -2.47250891e-01 3.94806377e-01 4.65838039e-01 2.13030019 0.87318756 348.25 -2.11168877e-01 3.91782845e-01 4.45068638e-01 2.06515093 0.87911762 348.50 -1.16078755e-01 3.84702251e-01 4.01833422e-01 1.86384558 0.87305729 348.75 -1.10434746e-01 3.64547157e-01 3.80907421e-01 1.86494524 0.87961669 349.00 -1.11887249e-01 2.93189299e-01 3.13813195e-01 1.93535920 0.83715084 349.25 -1.28742038e-01 2.65842050e-01 2.95375198e-01 2.02178919 0.82338265 349.50 -1.36817892e-01 2.07463480e-01 2.48516058e-01 2.15380662 0.77108228 349.75 -1.42455911e-01 1.69681632e-01 2.21552574e-01 2.26919121 0.65930429 350.00 -2.40973193e-01 1.25052304e-01 2.71488782e-01 2.66290263 0.71216699 350.25 -2.83638750e-01 6.14937776e-02 2.90228230e-01 2.92809364 0.67999668 350.50 -3.78134707e-01 -3.66630139e-02 3.79907927e-01 -3.04493723 0.84001386 350.75 -4.45411570e-01 -6.23012613e-02 4.49747611e-01 -3.00262081 0.82802041 351.00 -6.54629686e-01 -1.01549901e-01 6.62459363e-01 -2.98769359 0.90022191 351.25 -7.53418154e-01 -1.68166311e-02 7.53605808e-01 -3.11927591 0.91625062 351.50 -9.24926482e-01 4.84765562e-02 9.26195969e-01 3.08922931 0.94611356 351.75 -1.02102001e+00 1.23018297e-01 1.02840428e+00 3.02168496 0.94258328 352.00 -1.14713776e+00 2.86631338e-01 1.18240541e+00 2.89673961 0.93995150 352.25 -1.19649772e+00 4.97839270e-01 1.29593624e+00 2.74730116 0.91653037 352.50 -1.24532232e+00 7.12626138e-01 1.43480441e+00 2.62183331 0.95583830 352.75 -1.12854410e+00 9.30831955e-01 1.46289436e+00 2.45190699 0.94199791 353.00 -9.75522006e-01 1.18695244e+00 1.53639165e+00 2.25873181 0.96656751 353.25 -7.97188022e-01 1.31558282e+00 1.53826750e+00 2.11558524 0.95667913 353.50 -5.63812451e-01 1.46391168e+00 1.56873258e+00 1.93842799 0.97058533 353.75 -3.65784085e-01 1.43578813e+00 1.48164961e+00 1.82025171 0.95323814 354.00 -9.61435246e-02 1.30556081e+00 1.30909610e+00 1.64430519 0.95715902 354.25 4.21652321e-02 1.19679832e+00 1.19754086e+00 1.53557920 0.96464853 354.50 4.09119081e-02 1.10835649e+00 1.10911130e+00 1.53390085 0.97802443 354.75 9.80874667e-02 9.78979630e-01 9.83881226e-01 1.47093602 0.96880078 355.00 1.08378381e-01 8.97388218e-01 9.03909004e-01 1.45060752 0.97429078 355.25 1.11830244e-01 7.95198509e-01 8.03023456e-01 1.43108073 0.97001269 355.50 1.04802334e-01 7.60702069e-01 7.67887471e-01 1.43388765 0.97756002 355.75 8.36078724e-02 7.03725383e-01 7.08674602e-01 1.45254311 0.97568394 356.00 7.33725544e-02 6.75239007e-01 6.79213698e-01 1.46255939 0.98246534 356.25 6.77630716e-02 6.08268445e-01 6.12031319e-01 1.45985056 0.97396722 356.50 6.24283941e-02 5.65864788e-01 5.69298044e-01 1.46091681 0.97945939 356.75 4.71365696e-02 5.24408469e-01 5.26522648e-01 1.48115201 0.96380580 357.00 2.58299922e-02 4.78677111e-01 4.79373513e-01 1.51688741 0.95295368 357.25 -1.18452805e-03 4.22871635e-01 4.22873294e-01 1.57359747 0.93646556 357.50 -2.18693668e-02 3.76959653e-01 3.77593498e-01 1.62874651 0.92506411 357.75 -9.08590977e-02 3.06217347e-01 3.19412647e-01 1.85923609 0.85331974 358.00 -1.52440725e-01 2.73774834e-01 3.13354168e-01 2.07885335 0.81643329 358.25 -3.50289788e-01 2.20501485e-01 4.13912842e-01 2.57977606 0.80228874 358.50 -4.67442890e-01 2.02067969e-01 5.09248779e-01 2.73356881 0.87895660 358.75 -6.86498554e-01 2.56991775e-01 7.33024581e-01 2.78339064 0.88912016 359.00 -8.13195185e-01 3.48446430e-01 8.84704088e-01 2.73676922 0.89061321 359.25 -9.39833102e-01 7.06901195e-01 1.17600832e+00 2.49671307 0.92249220 359.50 -9.41792089e-01 8.55766385e-01 1.27252051e+00 2.40401498 0.91604197 359.75 -7.25967885e-01 1.20198058e+00 1.40420322e+00 2.11413451 0.90786827 360.00 -5.95148189e-01 1.30895546e+00 1.43790325e+00 1.99753046 0.94454632 360.25 -4.64685849e-01 1.34855054e+00 1.42636653e+00 1.90263603 0.96538589 360.50 -4.36413087e-01 1.36298349e+00 1.43114652e+00 1.88067122 0.97208510 360.75 -4.07901491e-01 1.43579616e+00 1.49261323e+00 1.84759761 0.97273785 361.00 -3.60165130e-01 1.51140050e+00 1.55372147e+00 1.80473227 0.96966539 361.25 -2.84284250e-01 1.63223361e+00 1.65680539e+00 1.74323543 0.95262068 361.50 -1.45495552e-01 1.76620831e+00 1.77219094e+00 1.65298809 0.92137517 361.75 1.89890668e-01 2.07973577e+00 2.08838678e+00 1.47974360 0.93056186 362.00 5.75273733e-01 2.02667167e+00 2.10673632e+00 1.29421974 0.88747850 362.25 1.41797550e+00 1.59212316e+00 2.13202033e+00 0.84318821 0.87738021 362.50 1.44929057e+00 1.05421884e+00 1.79215527e+00 0.62888173 0.85547357 362.75 1.09329365e+00 7.10482923e-01 1.30387000e+00 0.57627365 0.92735201 363.00 9.74305300e-01 7.74870813e-01 1.24486770e+00 0.67187216 0.95079945 363.25 1.02137400e+00 8.80402864e-01 1.34844876e+00 0.71140747 0.94095868 363.50 1.12247649e+00 7.10200738e-01 1.32828407e+00 0.56412352 0.91984576 363.75 1.15787775e+00 4.74630937e-01 1.25138140e+00 0.38902407 0.95792007 364.00 1.11219163e+00 4.25604339e-01 1.19084393e+00 0.36547958 0.96475524 364.25 1.10153896e+00 4.12736297e-01 1.17632450e+00 0.35849939 0.97511786 364.50 1.12024484e+00 3.38349164e-01 1.17022590e+00 0.29331946 0.96337088 364.75 1.15348723e+00 2.22196114e-01 1.17469311e+00 0.19029897 0.96601728 365.00 1.11576035e+00 2.61569109e-02 1.11606691e+00 0.02343883 0.96359199 365.25 1.03047206e+00 -8.94468220e-02 1.03434684e+00 -0.08658477 0.96725006 365.50 9.24603761e-01 -2.03609454e-01 9.46757057e-01 -0.21675314 0.94895258 365.75 8.10392355e-01 -3.02559500e-01 8.65030647e-01 -0.35732278 0.95313673 366.00 6.39810528e-01 -3.42044925e-01 7.25501373e-01 -0.49094566 0.92962129 366.25 5.14645324e-01 -3.35130123e-01 6.14143313e-01 -0.57720891 0.93079126 366.50 3.58425321e-01 -3.17402661e-01 4.78762112e-01 -0.72477269 0.87151138 366.75 2.76789978e-01 -2.80108281e-01 3.93793526e-01 -0.79135664 0.87817708 367.00 1.99495520e-01 -2.42705006e-01 3.14172218e-01 -0.88280362 0.73243035 367.25 1.36804423e-01 -1.67249800e-01 2.16073936e-01 -0.88519692 0.58594714 367.50 1.84105778e-01 -8.76412687e-02 2.03901765e-01 -0.44429457 0.52102849 367.75 1.94824639e-01 -4.90560985e-02 2.00905801e-01 -0.24666846 0.55245266 368.00 2.44501678e-01 -1.15221537e-02 2.44773019e-01 -0.04709021 0.55399642 368.25 3.02087466e-01 -3.79837397e-02 3.04466092e-01 -0.12508114 0.67848008 368.50 3.02349651e-01 -1.05496269e-01 3.20226130e-01 -0.33571362 0.75144027 368.75 3.08493623e-01 -1.25498732e-01 3.33043912e-01 -0.38636447 0.75229948 369.00 2.81218000e-01 -1.55171369e-01 3.21187978e-01 -0.50421124 0.68706816 369.25 2.52697410e-01 -1.76141977e-01 3.08029182e-01 -0.60874135 0.61411256 369.50 1.58077731e-01 -2.82922717e-01 3.24089236e-01 -1.06127447 0.65862697 369.75 1.14380616e-01 -3.22213084e-01 3.41912558e-01 -1.22968799 0.69784495 370.00 -1.11088933e-01 -3.10379568e-01 3.29660776e-01 -1.91450327 0.70819443 370.25 -1.74421001e-01 -2.57039763e-01 3.10631817e-01 -2.16699856 0.76691431 370.50 -1.90818539e-01 -1.90112781e-01 2.69359582e-01 -2.35804721 0.74506620 370.75 -2.13016849e-01 -1.50751433e-01 2.60963930e-01 -2.52571942 0.72505782 371.00 -2.29388977e-01 -9.67693142e-02 2.48965063e-01 -2.74238728 0.80953874 371.25 -2.44831356e-01 -6.88964639e-02 2.54340551e-01 -2.86728272 0.79828463 371.50 -3.01909466e-01 -1.81141864e-02 3.02452392e-01 -3.08166576 0.87991041 371.75 -3.08353508e-01 2.53731400e-02 3.09395672e-01 3.05949174 0.86461763 372.00 -3.26864626e-01 1.39210333e-01 3.55274543e-01 2.73896334 0.89102776 372.25 -2.84762264e-01 1.85886789e-01 3.40063884e-01 2.56326640 0.85140521 372.50 -1.66102036e-01 2.54431964e-01 3.03851132e-01 2.14916178 0.76254071 372.75 -3.10298738e-02 1.93670164e-01 1.96140219e-01 1.72966629 0.38006425 373.00 7.78680386e-02 -5.46834153e-02 9.51509714e-02 -0.61223947 0.07003974 373.25 -8.20215957e-02 -2.55995926e-01 2.68814911e-01 -1.88086385 0.20655434 373.50 -6.56411385e-01 -2.74641729e-01 7.11550409e-01 -2.74532655 0.62488077 373.75 -8.95832842e-01 2.59205369e-02 8.96207764e-01 3.11266616 0.68790097 374.00 -8.69333216e-01 5.91713169e-01 1.05160102e+00 2.54397046 0.75520691 374.25 -5.92970856e-01 9.07639045e-01 1.08416930e+00 2.14949584 0.81262471 374.50 -2.41072477e-01 1.04279755e+00 1.07030027e+00 1.79798381 0.88848384 374.75 6.60103377e-02 9.25241009e-01 9.27592739e-01 1.49957307 0.88403902 375.00 2.98765961e-01 7.81720556e-01 8.36868047e-01 1.20573684 0.90221613 375.25 3.34673677e-01 5.80470140e-01 6.70038845e-01 1.04779328 0.89886301 375.50 3.57834335e-01 4.58382948e-01 5.81515553e-01 0.90796917 0.91695718 375.75 3.16359089e-01 3.42805687e-01 4.66474878e-01 0.82549803 0.90188943 376.00 2.63628687e-01 2.95599128e-01 3.96079448e-01 0.84250491 0.92619227 376.25 2.01168024e-01 2.50197330e-01 3.21040929e-01 0.89359837 0.88903682 376.50 1.46205603e-01 2.35242657e-01 2.76975064e-01 1.01471080 0.87834289 376.75 1.53116217e-01 2.54081791e-01 2.96651534e-01 1.02844840 0.91617755 377.00 1.61616584e-01 2.45663631e-01 2.94058735e-01 0.98890321 0.94706486 377.25 1.60446193e-01 2.23900798e-01 2.75453350e-01 0.94901939 0.92066112 377.50 1.54084965e-01 2.07165769e-01 2.58185655e-01 0.93129037 0.92743977 377.75 1.66515387e-01 1.91531329e-01 2.53794453e-01 0.85515262 0.91310099 378.00 1.68150528e-01 1.74977940e-01 2.42676492e-01 0.80529308 0.91791995 378.25 1.60481888e-01 1.20663714e-01 2.00783884e-01 0.64470558 0.83886110 378.50 1.43635364e-01 9.67282272e-02 1.73168900e-01 0.59266965 0.83173986 378.75 1.23814180e-01 7.51474880e-02 1.44834720e-01 0.54550511 0.75920438 379.00 1.01573441e-01 6.03277144e-02 1.18138042e-01 0.53594577 0.67618023 379.25 5.10578894e-02 2.85784237e-02 5.85118311e-02 0.51027964 0.27891090 379.50 1.92194377e-02 2.56174290e-02 3.20256062e-02 0.92713620 0.11556222 379.75 -1.79395347e-02 3.44405317e-02 3.88326812e-02 2.05101150 0.13818314 380.00 -4.63982518e-02 5.36722200e-02 7.09471985e-02 2.28363365 0.31650123 380.25 -1.17498298e-01 9.59992170e-02 1.51729034e-01 2.45655561 0.72372860 380.50 -1.19458181e-01 1.10662817e-01 1.62838927e-01 2.39439650 0.76168342 380.75 -1.10811230e-01 1.38404496e-01 1.77298994e-01 2.24592323 0.81763840 381.00 -1.15382989e-01 1.60952136e-01 1.98037432e-01 2.19275999 0.81662461 381.25 -1.15232699e-01 2.09459638e-01 2.39064667e-01 2.07374912 0.87784038 381.50 -1.08657286e-01 2.35019672e-01 2.58922096e-01 2.00385869 0.88668523 381.75 -7.66563666e-02 2.71465280e-01 2.82080834e-01 1.84601064 0.93072900 382.00 -5.32881403e-02 2.66643156e-01 2.71915793e-01 1.76804587 0.92944999 382.25 -2.41614333e-02 2.44424866e-01 2.45616144e-01 1.66932638 0.92204032 382.50 -1.27154725e-02 2.27401805e-01 2.27757029e-01 1.62665448 0.90423205 382.75 -1.34384248e-02 2.19809367e-01 2.20219774e-01 1.63185705 0.94256529 383.00 -1.87692347e-02 2.13168893e-01 2.13993600e-01 1.65861850 0.92406850 383.25 -2.86645258e-02 1.91857216e-01 1.93986717e-01 1.71910482 0.91381951 383.50 -3.82858805e-02 1.85491465e-01 1.89401405e-01 1.77434038 0.86704687 383.75 -5.14972982e-02 1.67021404e-01 1.74780208e-01 1.86987545 0.87340809 384.00 -5.63425187e-02 1.62651577e-01 1.72133712e-01 1.90426049 0.81187175 384.25 -7.17843363e-02 1.54262129e-01 1.70146394e-01 2.00633350 0.81165051 384.50 -8.97118754e-02 1.70550270e-01 1.92706033e-01 2.05503811 0.77567539 384.75 -1.25788782e-01 1.78344618e-01 2.18242114e-01 2.18507919 0.84370076 385.00 -1.21431616e-01 1.77191004e-01 2.14807563e-01 2.17159830 0.74851743 385.25 -1.17324000e-01 2.11536542e-01 2.41893839e-01 2.07718543 0.81023214 385.50 -9.78152622e-02 1.79197417e-01 2.04155675e-01 2.07044929 0.63226920 385.75 -9.95363535e-02 1.08275486e-01 1.47075037e-01 2.31416615 0.47754648 386.00 -1.60478558e-01 6.56438414e-02 1.73385356e-01 2.75330851 0.39521881 386.25 -2.26545149e-01 5.85982075e-02 2.34000971e-01 2.88847999 0.53986001 386.50 -1.96222532e-01 4.16517026e-02 2.00594482e-01 2.93242955 0.42864368 386.75 -1.76118575e-01 -7.43742131e-03 1.76275545e-01 -3.09938811 0.45322515 387.00 -1.17655870e-01 -7.26643257e-02 1.38285964e-01 -2.58833202 0.25623095 387.25 -4.30391930e-02 -9.25782328e-02 1.02093591e-01 -2.00596798 0.16485184 387.50 6.66056997e-02 -6.79830714e-02 9.51736162e-02 -0.79563173 0.11724031 387.75 6.49798509e-02 -4.29939982e-02 7.79157552e-02 -0.58452233 0.10607589 388.00 5.39243317e-02 2.38985206e-02 5.89828182e-02 0.41717315 0.11062614 388.25 5.69366308e-02 7.06538450e-02 9.07399898e-02 0.89249650 0.34411174 388.50 5.96120204e-02 1.34470137e-01 1.47091165e-01 1.15351932 0.62329427 388.75 6.95282069e-02 1.69425188e-01 1.83136741e-01 1.18137636 0.73812054 389.00 8.33332128e-02 2.07442379e-01 2.23554837e-01 1.18881031 0.78895674 389.25 1.00439846e-01 2.20502043e-01 2.42300049e-01 1.14337365 0.83034223 389.50 1.46793560e-01 2.32728837e-01 2.75156429e-01 1.00807333 0.88942179 389.75 1.49538514e-01 2.45114700e-01 2.87128862e-01 1.02300117 0.91815431 390.00 1.67357663e-01 2.53289566e-01 3.03585559e-01 0.98691046 0.94525679 390.25 1.78605465e-01 2.51463535e-01 3.08437711e-01 0.95321502 0.93233836 390.50 1.99568704e-01 2.64044742e-01 3.30979295e-01 0.92358465 0.95392950 390.75 2.12158911e-01 2.60748986e-01 3.36156864e-01 0.88778630 0.94516777 391.00 2.63302619e-01 2.20238657e-01 3.43268605e-01 0.69657297 0.92862321 391.25 2.94391209e-01 1.92131147e-01 3.51540270e-01 0.57822808 0.92944998 391.50 3.13069522e-01 1.22734106e-01 3.36268027e-01 0.37362091 0.91477441 391.75 3.01489497e-01 7.59735109e-02 3.10914604e-01 0.24685438 0.87066252 392.00 2.80731897e-01 -4.96429228e-03 2.80775787e-01 -0.01768155 0.88800897 392.25 2.46033138e-01 -8.85817774e-03 2.46192551e-01 -0.03598846 0.82018456 392.50 1.89960025e-01 -1.90909982e-02 1.90916938e-01 -0.10016376 0.84642937 392.75 1.71233733e-01 -2.97864538e-02 1.73805133e-01 -0.17222865 0.78947503 393.00 1.13865502e-01 -4.30859082e-02 1.21744602e-01 -0.36174203 0.66654855 393.25 9.95393101e-02 -5.90784530e-02 1.15751189e-01 -0.53564029 0.61298886 393.50 6.44751789e-02 -8.02339652e-02 1.02929771e-01 -0.89387044 0.53023806 393.75 3.08026388e-02 -8.15164592e-02 8.71420431e-02 -1.20951172 0.45700404 394.00 -2.03298770e-02 -7.98434356e-02 8.23910074e-02 -1.82012014 0.44499842 394.25 -6.27593919e-02 -7.84768078e-02 1.00485574e-01 -2.24536589 0.47777154 394.50 -1.38654936e-01 -8.13080893e-02 1.60736420e-01 -2.61122870 0.57853425 394.75 -2.05520554e-01 -6.54578199e-02 2.15692893e-01 -2.83325307 0.63336033 395.00 -3.07509599e-01 -1.45125057e-02 3.07851858e-01 -3.09443398 0.71441970 395.25 -3.77564160e-01 7.81580528e-02 3.85568899e-01 2.93746970 0.71124851 395.50 -4.28727069e-01 1.64684524e-01 4.59268867e-01 2.77484661 0.72277723 395.75 -4.25097119e-01 2.75277528e-01 5.06443756e-01 2.56693192 0.63052526 396.00 -3.72113872e-01 4.63748153e-01 5.94584799e-01 2.24700206 0.66868963 396.25 -3.39124994e-01 4.82630585e-01 5.89862733e-01 2.18330500 0.59398921 396.50 -3.10564759e-01 5.63815065e-01 6.43690840e-01 2.07427452 0.60633272 396.75 -2.20209051e-01 6.61486166e-01 6.97177147e-01 1.89215725 0.69650188 397.00 -1.76077376e-01 7.70375225e-01 7.90241248e-01 1.79549715 0.76714380 397.25 1.69856991e-02 8.19129636e-01 8.19305727e-01 1.55006302 0.66829952 397.50 1.37482572e-01 9.22314744e-01 9.32505198e-01 1.42282334 0.74215978 397.75 8.92800320e-02 1.00713767e+00 1.01108714e+00 1.48238015 0.77574005 398.00 1.46216753e-01 1.03584793e+00 1.04611676e+00 1.43056622 0.77938606 398.25 2.77512602e-01 1.17718221e+00 1.20945078e+00 1.33928026 0.78897226 398.50 3.56363092e-01 1.32975997e+00 1.37668305e+00 1.30895836 0.76988303 398.75 4.57391192e-01 1.67632548e+00 1.73760577e+00 1.30442684 0.78733852 399.00 4.44571472e-01 1.85452288e+00 1.90706552e+00 1.33551344 0.76821364 399.25 6.72188862e-01 1.97021666e+00 2.08172802e+00 1.24200486 0.66308555 399.50 5.61143526e-01 1.97014946e+00 2.04850457e+00 1.29332105 0.62883612 399.75 2.15192676e-01 2.13749346e+00 2.14829844e+00 1.47045916 0.50562167 400.00 6.21774456e-03 2.47761558e+00 2.47762338e+00 1.56828676 0.52071627 400.25 -1.23382012e+00 1.78938911e+00 2.17352835e+00 2.17445426 0.53332779 400.50 -1.42981836e+00 1.46555601e+00 2.04749480e+00 2.34385210 0.63113804 400.75 -1.23054307e+00 1.10818331e+00 1.65599109e+00 2.40846580 0.76328602 401.00 -1.14270103e+00 9.40402862e-01 1.47990648e+00 2.45300473 0.82262190 401.25 -8.65941785e-01 7.57518875e-01 1.15051728e+00 2.42288052 0.81849127 401.50 -7.84279890e-01 5.87948061e-01 9.80192771e-01 2.49830526 0.84178565 401.75 -6.56384704e-01 5.27419665e-01 8.42028730e-01 2.46470773 0.87644884 402.00 -6.21654375e-01 4.88450285e-01 7.90593349e-01 2.47561590 0.84690511 402.25 -5.91646991e-01 5.74834333e-01 8.24912524e-01 2.37060663 0.89274403 402.50 -5.65985517e-01 5.90862645e-01 8.18204297e-01 2.33469357 0.85634809 402.75 -5.95214703e-01 6.36929107e-01 8.71756405e-01 2.32235227 0.66736532 403.00 -4.67720006e-01 7.33988398e-01 8.70345318e-01 2.13814251 0.56976166 403.25 -2.05847098e-01 7.68571193e-01 7.95659919e-01 1.83248532 0.40581797 403.50 1.81616438e-03 4.60966436e-01 4.60970014e-01 1.56685644 0.15371689 403.75 -4.66781258e-02 -1.00683363e-02 4.77516369e-02 -2.92915029 0.00234050 404.00 -2.31708482e-01 -1.45675844e-01 2.73697410e-01 -2.58033485 0.11641839 404.25 -3.67050734e-01 -1.44927568e-01 3.94626711e-01 -2.76553949 0.36820871 404.50 -3.08453471e-01 8.47732387e-02 3.19890678e-01 2.87338157 0.28335166 404.75 -2.80963021e-01 2.78631162e-01 3.95696277e-01 2.36036152 0.58682573 405.00 -2.19334982e-01 2.52464399e-01 3.34434011e-01 2.28609027 0.55357360 405.25 -7.38177643e-02 1.46596781e-01 1.64133112e-01 2.03727421 0.29844624 405.50 -3.41951965e-02 1.62118619e-03 3.42336049e-02 3.09421836 0.01605674 405.75 -1.33323964e-01 -1.35944986e-01 1.90410920e-01 -2.34646095 0.34457933 406.00 -2.44411931e-01 -2.06652777e-01 3.20066497e-01 -2.43971094 0.47707846 406.25 -3.45859522e-01 -2.37805714e-01 4.19726538e-01 -2.53925172 0.63088121 406.50 -4.25103264e-01 -2.86559129e-01 5.12668430e-01 -2.54846636 0.67787159 406.75 -5.77695457e-01 -3.22434220e-01 6.61585873e-01 -2.63252236 0.74208273 407.00 -7.62011119e-01 -2.98214912e-01 8.18286673e-01 -2.76856322 0.76032650 407.25 -9.47329207e-01 -3.14337371e-01 9.98118535e-01 -2.82120986 0.77406473 407.50 -1.18257442e+00 -1.01888595e-01 1.18695558e+00 -3.05564661 0.63442685 407.75 -1.31251594e+00 3.14565115e-01 1.34968489e+00 2.90636374 0.61296117 408.00 -8.66159189e-01 5.44942079e-01 1.02332478e+00 2.58001627 0.58637937 408.25 -6.81375031e-01 6.91984471e-01 9.71140794e-01 2.34846947 0.65574188 408.50 -6.35334933e-01 5.79546045e-01 8.59955868e-01 2.40208353 0.57262250 408.75 -7.00553156e-01 4.38228101e-01 8.26328380e-01 2.58260093 0.57210906 409.00 -6.21153067e-01 3.32705802e-01 7.04644792e-01 2.64985199 0.52318541 409.25 -6.25585216e-01 2.51313471e-01 6.74177517e-01 2.75959975 0.54580838 409.50 -7.83054871e-01 4.05780586e-01 8.81948306e-01 2.66348972 0.62558298 409.75 -8.78380955e-01 4.23949798e-01 9.75339189e-01 2.69192185 0.69276662 410.00 -9.22144230e-01 4.39840488e-01 1.02167002e+00 2.69653347 0.67303310 410.25 -1.01459656e+00 4.62537902e-01 1.11505493e+00 2.71385673 0.71196636 410.50 -1.03367442e+00 6.06332052e-01 1.19838281e+00 2.61109974 0.75283245 410.75 -1.10293344e+00 7.46441428e-01 1.33177963e+00 2.54662231 0.80923382 411.00 -1.18695981e+00 1.01160866e+00 1.55955945e+00 2.43578298 0.88280501 411.25 -1.14287799e+00 1.13398495e+00 1.60999751e+00 2.36010030 0.91705328 411.50 -1.07074361e+00 1.16420516e+00 1.58172865e+00 2.31440064 0.90260603 411.75 -1.05463494e+00 1.16781538e+00 1.57354619e+00 2.30531248 0.90497008 412.00 -9.92620815e-01 1.24109545e+00 1.58921804e+00 2.24541171 0.92737254 412.25 -9.70527056e-01 1.37459888e+00 1.68268977e+00 2.18556704 0.94654223 412.50 -9.13268891e-01 1.36765124e+00 1.64454553e+00 2.15955855 0.94934070 412.75 -8.91773995e-01 1.34648881e+00 1.61502105e+00 2.15576689 0.93714356 413.00 -9.12888966e-01 1.40325484e+00 1.67406404e+00 2.14755886 0.94409904 413.25 -9.08203268e-01 1.40320214e+00 1.67146924e+00 2.14522620 0.94700100 413.50 -1.03989254e+00 1.42118872e+00 1.76100933e+00 2.20248621 0.95145156 413.75 -1.07721147e+00 1.44636071e+00 1.80342559e+00 2.21094423 0.95433388 414.00 -1.20826777e+00 1.48138152e+00 1.91164908e+00 2.25499883 0.96010542 414.25 -1.36803336e+00 1.58578640e+00 2.09433373e+00 2.28260846 0.93772179 414.50 -1.62018824e+00 1.92124918e+00 2.51320679e+00 2.27138745 0.96185294 414.75 -1.67162371e+00 2.13855581e+00 2.71435937e+00 2.23425392 0.94442836 415.00 -1.70619657e+00 2.62318727e+00 3.12925202e+00 2.14747294 0.94923319 415.25 -1.56673856e+00 2.86907229e+00 3.26898234e+00 2.07062377 0.94660299 415.50 -1.57626739e+00 3.44522771e+00 3.78869540e+00 1.99988790 0.96019584 415.75 -1.31000436e+00 3.77034435e+00 3.99144184e+00 1.90519721 0.94262342 416.00 -9.48719241e-01 4.18382897e+00 4.29004580e+00 1.79378401 0.95985768 416.25 -5.32020925e-01 4.27070429e+00 4.30371484e+00 1.69473236 0.93904102 416.50 -1.95053548e-01 4.49936049e+00 4.50358643e+00 1.61412059 0.95655662 416.75 4.42896614e-02 4.65250965e+00 4.65272046e+00 1.56127709 0.94482958 417.00 4.94495193e-01 4.72421300e+00 4.75002253e+00 1.46650361 0.93873521 417.25 9.63768119e-01 4.81659566e+00 4.91207112e+00 1.37331114 0.93616882 417.50 1.34114132e+00 5.08652928e+00 5.26036502e+00 1.31299812 0.95651483 417.75 1.95195861e+00 4.87024048e+00 5.24684522e+00 1.18960646 0.91975818 418.00 2.74387877e+00 4.68893715e+00 5.43277114e+00 1.04134413 0.94432532 418.25 3.23862135e+00 4.37127033e+00 5.44028240e+00 0.93315251 0.93531527 418.50 3.61253987e+00 4.14545221e+00 5.49865605e+00 0.85398247 0.94093648 418.75 3.74186069e+00 3.54038397e+00 5.15129499e+00 0.75773838 0.94041692 419.00 3.90886035e+00 3.23300376e+00 5.07262285e+00 0.69104607 0.95693743 419.25 3.95162247e+00 2.67963566e+00 4.77449132e+00 0.59588329 0.93255685 419.50 4.04606167e+00 2.48001116e+00 4.74563699e+00 0.54988317 0.94020998 419.75 3.89170371e+00 2.14532306e+00 4.44384618e+00 0.50380661 0.93979492 420.00 3.89308131e+00 2.00990241e+00 4.38130001e+00 0.47658305 0.94799642 420.25 3.93437867e+00 1.65729143e+00 4.26918615e+00 0.39867592 0.92312364 420.50 3.99063994e+00 1.37536486e+00 4.22099937e+00 0.33189869 0.92340557 420.75 3.74737197e+00 9.26666227e-01 3.86024701e+00 0.24242107 0.93528863 421.00 3.68435307e+00 7.04293067e-01 3.75106468e+00 0.18887923 0.93568182 421.25 3.55836814e+00 6.07852875e-01 3.60991260e+00 0.16919041 0.92443507 421.50 3.44823340e+00 5.79401001e-01 3.49657248e+00 0.16647327 0.90401218 421.75 3.19381844e+00 3.77361613e-01 3.21603452e+00 0.11760849 0.90078507 422.00 3.12478224e+00 2.53573525e-01 3.13505400e+00 0.08097176 0.91998171 422.25 2.91385807e+00 3.50540289e-01 2.93486751e+00 0.11972573 0.89460107 422.50 2.83590141e+00 4.31017450e-01 2.86846873e+00 0.15083173 0.88249515 422.75 2.83068726e+00 3.88656218e-01 2.85724413e+00 0.13644786 0.89680179 423.00 2.87016513e+00 4.09171904e-01 2.89918429e+00 0.14160624 0.90035381 423.25 2.82377865e+00 3.84663471e-01 2.84985822e+00 0.13538960 0.91026319 423.50 2.84700612e+00 2.81824680e-01 2.86092100e+00 0.09866839 0.90396141 423.75 2.92880053e+00 1.39063214e-01 2.93210012e+00 0.04744565 0.92631604 424.00 2.86191122e+00 4.47031997e-02 2.86226034e+00 0.01561878 0.90842070 424.25 2.96422368e+00 -3.21486592e-02 2.96439801e+00 -0.01084513 0.93721301 424.50 3.03734738e+00 -1.37004650e-01 3.04043572e+00 -0.04507612 0.91504646 424.75 2.88580945e+00 -2.97956614e-01 2.90115052e+00 -0.10288433 0.89536847 425.00 2.84414246e+00 -5.49849262e-01 2.89680523e+00 -0.19097097 0.86647886 425.25 2.56573274e+00 -8.96504639e-01 2.71784935e+00 -0.33615326 0.86981455 425.50 2.22408110e+00 -1.00617287e+00 2.44109004e+00 -0.42484745 0.79615214 425.75 1.97004177e+00 -1.23967830e+00 2.32763117e+00 -0.56166039 0.79546383 426.00 1.44790888e+00 -1.24540407e+00 1.90983545e+00 -0.71035137 0.71652094 426.25 8.85019885e-01 -1.34283410e+00 1.60824862e+00 -0.98807234 0.68704152 426.50 4.90467623e-01 -1.21307679e+00 1.30847766e+00 -1.18657391 0.50531393 426.75 3.12087266e-02 -1.03192093e+00 1.03239275e+00 -1.54056221 0.49468591 427.00 -1.94398158e-01 -7.91983058e-01 8.15492372e-01 -1.81149512 0.40038998 427.25 -3.27701558e-01 -5.76680466e-01 6.63286266e-01 -2.08754679 0.36565468 427.50 -4.83357625e-01 -3.02574538e-01 5.70250773e-01 -2.58228546 0.35028322 427.75 -7.71146468e-01 -1.08778667e-01 7.78780890e-01 -3.00145629 0.56516292 428.00 -8.08527861e-01 6.01151220e-02 8.10759601e-01 3.06737788 0.51410098 428.25 -9.21957739e-01 2.88542263e-01 9.66055232e-01 2.83828247 0.62171804 428.50 -1.13043394e+00 2.99395067e-01 1.16940938e+00 2.88268738 0.71348928 428.75 -1.24994986e+00 3.13879775e-01 1.28875722e+00 2.89556590 0.76790547 429.00 -1.48446642e+00 5.40811794e-01 1.57991074e+00 2.79222335 0.78292416 429.25 -1.55326874e+00 7.58102166e-01 1.72839887e+00 2.68753540 0.82229087 429.50 -1.64965442e+00 7.35686769e-01 1.80626541e+00 2.72209999 0.81780963 429.75 -1.72658690e+00 7.81129238e-01 1.89506338e+00 2.71673443 0.81972178 430.00 -1.80432962e+00 8.52052263e-01 1.99539431e+00 2.70040967 0.82487279 430.25 -1.84210428e+00 9.79033713e-01 2.08611006e+00 2.65308268 0.84713486 430.50 -1.87464756e+00 1.05075521e+00 2.14904396e+00 2.63071759 0.78864862 430.75 -1.98059520e+00 8.94869735e-01 2.17337277e+00 2.71722741 0.82469854 431.00 -2.18014731e+00 8.92967032e-01 2.35593557e+00 2.75284628 0.85823397 431.25 -2.32011939e+00 8.19016098e-01 2.46043519e+00 2.80224238 0.87733266 431.50 -2.28611610e+00 6.08804504e-01 2.36579157e+00 2.88132780 0.86477050 431.75 -2.40748986e+00 5.61489743e-01 2.47209995e+00 2.91246231 0.90305247 432.00 -2.72807996e+00 5.18551981e-01 2.77692572e+00 2.95375401 0.88822835 432.25 -2.83987936e+00 5.11456449e-01 2.88556797e+00 2.96340484 0.92359798 432.50 -2.87560358e+00 3.74067792e-01 2.89983149e+00 3.01223581 0.93802628 432.75 -3.04511137e+00 3.08635587e-01 3.06071220e+00 3.04058314 0.93327306 433.00 -3.38276236e+00 2.30121548e-01 3.39058064e+00 3.07366960 0.94977707 433.25 -3.56184168e+00 3.06416983e-01 3.57499755e+00 3.05577626 0.95501406 433.50 -3.68595146e+00 2.63827573e-01 3.69538133e+00 3.07013799 0.95808253 433.75 -3.54074075e+00 4.63640499e-01 3.57096732e+00 3.01138897 0.95160110 434.00 -3.63662936e+00 7.22596399e-01 3.70772419e+00 2.94544790 0.94720272 434.25 -3.75623708e+00 8.02979867e-01 3.84110579e+00 2.93099014 0.93721757 434.50 -3.95792807e+00 1.09148476e+00 4.10567090e+00 2.87250909 0.93405757 434.75 -3.68732565e+00 1.17176656e+00 3.86903184e+00 2.83390277 0.89856072 435.00 -3.21288301e+00 1.11370354e+00 3.40043421e+00 2.80791712 0.92258138 435.25 -3.01042408e+00 1.18974671e+00 3.23699712e+00 2.76522325 0.93589311 435.50 -2.99987036e+00 1.23512499e+00 3.24418802e+00 2.75101860 0.95632525 435.75 -2.76566591e+00 1.11697279e+00 2.98270617e+00 2.75775350 0.93881319 436.00 -2.52564439e+00 8.56173316e-01 2.66681690e+00 2.81475795 0.93376728 436.25 -2.50954511e+00 6.07301026e-01 2.58198203e+00 2.90416081 0.92630172 436.50 -2.68555335e+00 3.46595888e-01 2.70782671e+00 3.01324273 0.91475399 436.75 -2.94825159e+00 3.23323834e-01 2.96592746e+00 3.03236285 0.90053158 437.00 -3.28429405e+00 5.48209161e-01 3.32973283e+00 2.97619904 0.93542618 437.25 -3.30676703e+00 7.56745688e-01 3.39225180e+00 2.91661905 0.93654841 437.50 -3.22361057e+00 9.45759188e-01 3.35948293e+00 2.85621560 0.94922094 437.75 -3.15927303e+00 1.15033981e+00 3.36218497e+00 2.79239867 0.93614440 438.00 -2.96785971e+00 1.25373076e+00 3.22180572e+00 2.74189575 0.92255439 438.25 -2.69253564e+00 1.42346772e+00 3.04565404e+00 2.65527155 0.91926134 438.50 -2.60787950e+00 1.42719890e+00 2.97286598e+00 2.64085235 0.94188695 438.75 -2.39227195e+00 1.32762454e+00 2.73597368e+00 2.63494639 0.93265042 439.00 -2.27050929e+00 1.40747517e+00 2.67136646e+00 2.58667347 0.95856595 439.25 -2.17672377e+00 1.32160053e+00 2.54651808e+00 2.59593148 0.95776174 439.50 -2.08185453e+00 1.30713845e+00 2.45819634e+00 2.58093065 0.95269634 439.75 -1.92783394e+00 1.33427612e+00 2.34453331e+00 2.53618060 0.94193721 440.00 -1.92218279e+00 1.40860743e+00 2.38305719e+00 2.50917994 0.94677461 440.25 -1.76738697e+00 1.40571595e+00 2.25825021e+00 2.46968495 0.94625221 440.50 -1.69362861e+00 1.35488910e+00 2.16889427e+00 2.46685668 0.95754632 440.75 -1.61164758e+00 1.29042564e+00 2.06460801e+00 2.46643281 0.95559722 441.00 -1.62141161e+00 1.27402211e+00 2.06206400e+00 2.47560212 0.94965861 441.25 -1.48974393e+00 1.16139150e+00 1.88895929e+00 2.47942047 0.94363009 441.50 -1.42156142e+00 1.09900233e+00 1.79684250e+00 2.48347371 0.94781628 441.75 -1.28356907e+00 1.07256113e+00 1.67270349e+00 2.44551320 0.92857879 442.00 -1.27949564e+00 1.11277400e+00 1.69569309e+00 2.42577381 0.92326127 442.25 -1.17246564e+00 1.05121877e+00 1.57471794e+00 2.41066577 0.94134923 442.50 -1.16345239e+00 1.00241704e+00 1.53572830e+00 2.43040930 0.95177333 442.75 -1.11277860e+00 8.53500891e-01 1.40240507e+00 2.48730019 0.94907414 443.00 -1.09536611e+00 8.16033442e-01 1.36592002e+00 2.50130763 0.94293873 443.25 -1.06565321e+00 7.82522915e-01 1.32210396e+00 2.50820710 0.94408952 443.50 -1.07174681e+00 7.71107022e-01 1.32032089e+00 2.51790808 0.94175213 443.75 -1.06213700e+00 7.31722218e-01 1.28978774e+00 2.53834503 0.94885220 444.00 -1.05859427e+00 6.78238662e-01 1.25723089e+00 2.57178482 0.93822782 444.25 -1.09140968e+00 6.08319786e-01 1.24949112e+00 2.63310817 0.90934480 444.50 -1.21003088e+00 5.57362556e-01 1.33222661e+00 2.70994359 0.90378854 444.75 -1.34372104e+00 5.76659592e-01 1.46223204e+00 2.73621110 0.90075537 445.00 -1.41682292e+00 6.64207041e-01 1.56478695e+00 2.70321484 0.89832558 445.25 -1.46409189e+00 8.19541613e-01 1.67785981e+00 2.63128626 0.91873615 445.50 -1.47922112e+00 9.36322783e-01 1.75065573e+00 2.57727288 0.89920356 445.75 -1.44787468e+00 1.03174239e+00 1.77787329e+00 2.52246628 0.87020005 446.00 -1.33102178e+00 1.03962984e+00 1.68891953e+00 2.47849741 0.81757396 446.25 -1.43407730e+00 1.03331172e+00 1.76757201e+00 2.51721329 0.76117397 446.50 -1.49371519e+00 1.05506856e+00 1.82875770e+00 2.52662531 0.68157944 446.75 -1.17208685e+00 1.34068749e+00 1.78079492e+00 2.28919750 0.60965555 447.00 -1.04367997e+00 1.45869780e+00 1.79361845e+00 2.19184111 0.51780132 447.25 -3.77811633e-01 1.88897189e+00 1.92638429e+00 1.76820067 0.42505537 447.50 1.04572298e-01 1.46737300e+00 1.47109445e+00 1.49965163 0.28266414 447.75 8.19821544e-01 6.81128705e-01 1.06585350e+00 0.69325646 0.19449873 448.00 6.93294783e-01 2.54092818e-01 7.38390694e-01 0.35129823 0.23147129 448.25 6.22395455e-01 1.08483336e-01 6.31779025e-01 0.17256609 0.38577968 448.50 3.66029771e-01 6.81348314e-02 3.72317268e-01 0.18403923 0.26566437 448.75 2.10376429e-01 2.52877924e-02 2.11890807e-01 0.11962864 0.20321347 449.00 1.53453043e-01 6.57568613e-02 1.66948498e-01 0.40484373 0.21925980 449.25 1.36079059e-01 9.28538588e-02 1.64740248e-01 0.59878342 0.28608084 449.50 5.70141396e-02 9.82999539e-02 1.13637551e-01 1.04521127 0.15393795 449.75 2.89138668e-02 6.70484009e-02 7.30171196e-02 1.16365331 0.07967491 450.00 7.91000820e-03 -7.69587194e-03 1.10360625e-02 -0.77167751 0.00149328 450.25 -1.66916660e-02 -5.41442486e-02 5.66587272e-02 -1.86983333 0.04980497 450.50 -1.48146651e-01 -1.01491422e-01 1.79577112e-01 -2.54095452 0.47207897 450.75 -1.98245611e-01 -9.56463402e-02 2.20112573e-01 -2.69207213 0.65168702 451.00 -3.00892150e-01 -6.98807619e-02 3.08900319e-01 -2.91339290 0.77758056 451.25 -3.60957020e-01 -3.71214559e-02 3.62860817e-01 -3.03911117 0.86266445 451.50 -3.97527485e-01 5.34856077e-02 4.01109476e-01 3.00785014 0.85704255 451.75 -4.09492912e-01 1.16515470e-01 4.25746756e-01 2.86438270 0.88693967 452.00 -3.58456686e-01 1.92279680e-01 4.06771031e-01 2.64924321 0.88449982 452.25 -3.24368423e-01 2.12336788e-01 3.87687742e-01 2.56197922 0.87880064 452.50 -2.32833216e-01 1.83201443e-01 2.96266899e-01 2.47493054 0.86439547 452.75 -2.13681586e-01 1.62604898e-01 2.68514753e-01 2.49110875 0.86508538 453.00 -2.14731399e-01 1.14330924e-01 2.43271728e-01 2.65233349 0.87897523 453.25 -2.16038904e-01 8.99726115e-02 2.34025381e-01 2.74697350 0.88579909 453.50 -2.42104233e-01 5.33413785e-02 2.47910795e-01 2.92473331 0.92325626 453.75 -2.59836617e-01 4.34052597e-02 2.63437059e-01 2.97607270 0.93834871 454.00 -2.91786415e-01 3.17094748e-02 2.93504349e-01 3.03334388 0.95513620 454.25 -3.15372931e-01 2.35849632e-02 3.16253595e-01 3.06694724 0.96324025 454.50 -3.36706709e-01 2.61019659e-02 3.37716924e-01 3.06422601 0.96993276 454.75 -3.53768811e-01 2.58904951e-02 3.54714941e-01 3.06853811 0.96388347 455.00 -3.83196743e-01 2.72564730e-02 3.84164885e-01 3.07058306 0.95460036 455.25 -3.90667449e-01 5.18661110e-02 3.94095355e-01 3.00960171 0.94688696 455.50 -4.26797274e-01 7.44034078e-02 4.33234094e-01 2.96899752 0.94279923 455.75 -4.42476430e-01 9.87417297e-02 4.53360034e-01 2.92203306 0.93840811 456.00 -4.65143874e-01 1.54321223e-01 4.90075365e-01 2.82124891 0.94517835 456.25 -4.86887751e-01 1.78047206e-01 5.18421151e-01 2.79101408 0.92181652 456.50 -5.05167464e-01 2.23889240e-01 5.52558194e-01 2.72440960 0.91615981 456.75 -4.97284687e-01 2.72771399e-01 5.67182771e-01 2.63988519 0.91710019 457.00 -4.81573551e-01 3.50520632e-01 5.95632268e-01 2.51240896 0.90567743 457.25 -3.95460688e-01 4.28986080e-01 5.83453693e-01 2.31555277 0.81303928 457.50 -2.76750127e-01 4.97186466e-01 5.69021103e-01 2.07871737 0.80991648 457.75 -2.31459697e-01 4.17529009e-01 4.77392988e-01 2.07697770 0.69658581 458.00 -1.50438151e-01 4.35189689e-01 4.60458144e-01 1.90362107 0.67625210 458.25 -1.25303533e-01 4.33730552e-01 4.51467792e-01 1.85203618 0.52741099 458.50 2.34597355e-03 4.52270773e-01 4.52276858e-01 1.56560927 0.42059756 458.75 1.51315490e-01 4.69749714e-01 4.93519171e-01 1.25917205 0.42898842 459.00 3.09511374e-01 5.61738697e-01 6.41363902e-01 1.06719476 0.61596859 459.25 4.97827579e-01 4.92426402e-01 7.00225721e-01 0.77994388 0.63739442 459.50 7.49007884e-01 3.28085688e-01 8.17712070e-01 0.41285270 0.69258845 459.75 8.85137224e-01 6.92525812e-03 8.85164315e-01 0.00782378 0.70512006 460.00 9.91209783e-01 -1.66011774e-01 1.00501579e+00 -0.16594381 0.78440438 460.25 7.75211575e-01 -4.90365108e-01 9.17284539e-01 -0.56401475 0.75960479 460.50 6.58010430e-01 -5.73208711e-01 8.72666002e-01 -0.71663055 0.85818364 460.75 6.47430578e-01 -6.37695411e-01 9.08747374e-01 -0.77782305 0.83582207 461.00 7.40904766e-01 -7.02200501e-01 1.02079646e+00 -0.75858447 0.84854457 461.25 7.50848790e-01 -1.00472941e+00 1.25429466e+00 -0.92901619 0.76813378 461.50 6.01432372e-01 -1.28073967e+00 1.41492579e+00 -1.13176502 0.81613637 461.75 1.29610066e-01 -1.49902296e+00 1.50461577e+00 -1.48454780 0.78433154 462.00 -1.43599609e-01 -1.49557787e+00 1.50245599e+00 -1.66651902 0.83848437 462.25 -5.32522066e-01 -1.33354046e+00 1.43593520e+00 -1.95072457 0.86207594 462.50 -6.77258805e-01 -1.27417405e+00 1.44298267e+00 -2.05934683 0.91466007 462.75 -8.32898592e-01 -1.22651107e+00 1.48258203e+00 -2.16734331 0.93146132 463.00 -8.89308897e-01 -1.19039831e+00 1.48590661e+00 -2.21241854 0.93473887 463.25 -1.07545137e+00 -9.49823160e-01 1.43483786e+00 -2.41814533 0.93621956 463.50 -1.14682340e+00 -7.99603940e-01 1.39805951e+00 -2.53272567 0.94021861 463.75 -1.21812839e+00 -5.50818578e-01 1.33687617e+00 -2.71692372 0.96639390 464.00 -1.13544277e+00 -4.84250582e-01 1.23439414e+00 -2.73846392 0.95477268 464.25 -9.73599809e-01 -3.36447730e-01 1.03009401e+00 -2.80886905 0.96373834 464.50 -9.31190779e-01 -2.80173268e-01 9.72426515e-01 -2.84933208 0.96818670 464.75 -8.07517242e-01 -2.52262394e-01 8.46002607e-01 -2.83880565 0.96628949 465.00 -7.68688111e-01 -2.63866119e-01 8.12715658e-01 -2.81092760 0.96303160 465.25 -6.75328216e-01 -2.90869681e-01 7.35304951e-01 -2.73489671 0.94707618 465.50 -6.36561238e-01 -3.28482426e-01 7.16317606e-01 -2.66520625 0.92786227 465.75 -5.72550966e-01 -4.12859571e-01 7.05880751e-01 -2.51685350 0.88877999 466.00 -5.07011625e-01 -4.94820944e-01 7.08455048e-01 -2.36836227 0.85167873 466.25 -4.84727372e-01 -6.92900777e-01 8.45619366e-01 -2.18122858 0.79837868 466.50 -5.46674133e-01 -8.16548463e-01 9.82651515e-01 -2.16075362 0.72052577 466.75 -1.03518107e+00 -1.31689241e+00 1.67505387e+00 -2.23699084 0.79933881 467.00 -1.39571426e+00 -1.30236006e+00 1.90896832e+00 -2.39078100 0.80251716 467.25 -1.96178459e+00 -9.97260847e-01 2.20071079e+00 -2.67129238 0.82982740 467.50 -2.25731234e+00 -4.91540528e-01 2.31021018e+00 -2.92718493 0.80799695 467.75 -2.35035169e+00 7.14836280e-02 2.35143849e+00 3.11118801 0.86166986 468.00 -2.07590252e+00 5.39413981e-01 2.14484002e+00 2.88736929 0.84110942 468.25 -2.00364239e+00 1.00348305e+00 2.24088399e+00 2.67728173 0.89208062 468.50 -1.58991171e+00 1.16773283e+00 1.97266804e+00 2.50810899 0.88736774 468.75 -1.32812043e+00 1.13289005e+00 1.74566427e+00 2.43535806 0.92423273 469.00 -1.16660065e+00 1.10601741e+00 1.60755454e+00 2.38284608 0.90380716 469.25 -1.07952562e+00 1.11650144e+00 1.55304573e+00 2.33935849 0.93056953 469.50 -1.00119785e+00 1.13038013e+00 1.51001866e+00 2.29566446 0.92004928 469.75 -9.47517087e-01 1.23169185e+00 1.55397988e+00 2.22652348 0.93984857 470.00 -8.45496294e-01 1.22897335e+00 1.49172366e+00 2.17340248 0.93050628 470.25 -7.41284093e-01 1.20818048e+00 1.41746329e+00 2.12112252 0.93880743 470.50 -5.93295881e-01 1.21552496e+00 1.35259045e+00 2.02487746 0.87205501 470.75 -4.03538064e-01 1.27370276e+00 1.33609943e+00 1.87761454 0.87992742 471.00 -1.89169688e-01 1.23989476e+00 1.25424247e+00 1.72219794 0.80263485 471.25 2.64444623e-02 1.18296258e+00 1.18325811e+00 1.54844561 0.74596721 471.50 4.05947741e-01 9.13576841e-01 9.99708063e-01 1.15265098 0.71022396 471.75 4.22988964e-01 7.62757310e-01 8.72191710e-01 1.06446464 0.74446277 472.00 3.84902255e-01 3.53093887e-01 5.22326563e-01 0.74232383 0.57039649 472.25 3.93073594e-01 2.51354173e-01 4.66568077e-01 0.56892881 0.62361170 472.50 2.69394533e-01 1.90853587e-01 3.30149218e-01 0.61637717 0.60376582 472.75 2.26469454e-01 1.78378789e-01 2.88283551e-01 0.66716529 0.60367435 473.00 2.24183724e-01 1.32959528e-01 2.60646462e-01 0.53531785 0.58068567 473.25 2.20097670e-01 9.40630737e-02 2.39355063e-01 0.40387609 0.58703678 473.50 1.77720637e-01 -6.88397781e-03 1.77853912e-01 -0.03871547 0.45803189 473.75 1.40901012e-01 -7.08590868e-02 1.57715267e-01 -0.46596474 0.39970462 474.00 2.68736903e-02 -1.93538773e-01 1.95395629e-01 -1.43282424 0.52760002 474.25 -4.67490428e-02 -2.18331089e-01 2.23279953e-01 -1.78173117 0.56385594 474.50 -2.54624708e-01 -2.71408852e-01 3.72151188e-01 -2.32429833 0.76536994 474.75 -3.78436802e-01 -2.69864817e-01 4.64802574e-01 -2.52212606 0.75767606 475.00 -6.97492770e-01 -1.45379025e-01 7.12482438e-01 -2.93610379 0.84400009 475.25 -8.30254894e-01 2.54872764e-02 8.30646008e-01 3.11090416 0.81012342 475.50 -9.48260833e-01 4.97860671e-01 1.07101067e+00 2.65812603 0.82092494 475.75 -7.97074956e-01 7.29243465e-01 1.08033537e+00 2.40060651 0.73422659 476.00 -2.21722554e-01 1.13070503e+00 1.15223902e+00 1.76443168 0.68408419 476.25 1.68894103e-01 1.03831464e+00 1.05196127e+00 1.40954681 0.69386196 476.50 4.05769689e-01 7.22327413e-01 8.28496188e-01 1.05897440 0.73730920 476.75 3.60362590e-01 4.89179718e-01 6.07583733e-01 0.93588304 0.63265557 477.00 2.84202315e-01 3.11587024e-01 4.21731466e-01 0.83132958 0.62864911 477.25 2.16970558e-01 2.27348674e-01 3.14266833e-01 0.80875126 0.47040175 477.50 6.28497633e-02 1.83853501e-01 1.94299260e-01 1.24140316 0.21996269 477.75 -1.09809057e-01 3.58668343e-01 3.75101332e-01 1.86789272 0.44379277 478.00 -2.46519954e-01 6.13492525e-01 6.61169544e-01 1.95287965 0.66099719 478.25 -3.95115665e-01 8.27232379e-01 9.16749582e-01 2.01639291 0.53812227 478.50 -6.53561129e-01 1.51983198e+00 1.65439759e+00 1.97691292 0.46682018 478.75 -1.06621499e+00 1.23028912e+00 1.62801281e+00 2.28487051 0.18308618 479.00 -1.68565885e+00 -8.68276359e-01 1.89614071e+00 -2.66594120 0.12206020 479.25 -1.46878832e+00 -2.21779717e+00 2.66006832e+00 -2.15575135 0.42147403 479.50 -1.53266036e+00 -2.85917964e+00 3.24406473e+00 -2.06286553 0.73298332 479.75 -1.43057200e+00 -2.17609701e+00 2.60421474e+00 -2.15235795 0.72451051 480.00 -1.51490982e+00 -2.00059836e+00 2.50945124e+00 -2.21890756 0.83249490 480.25 -1.53688393e+00 -1.57924876e+00 2.20364218e+00 -2.34260000 0.82158494 480.50 -1.69881318e+00 -1.21817085e+00 2.09043212e+00 -2.51950083 0.86901872 480.75 -1.64785209e+00 -8.60782454e-01 1.85912962e+00 -2.66021250 0.86536859 481.00 -1.60546476e+00 -5.60897990e-01 1.70062448e+00 -2.80548099 0.86697990 481.25 -1.45045280e+00 -1.26606960e-01 1.45596795e+00 -3.05452545 0.84923159 481.50 -1.34536290e+00 7.04204706e-02 1.34720465e+00 3.08929727 0.89065696 481.75 -1.06059696e+00 2.22703874e-01 1.08372641e+00 2.93461986 0.91476611 482.00 -9.38564036e-01 2.76911808e-01 9.78561495e-01 2.85469459 0.92748263 482.25 -6.94382417e-01 2.61525922e-01 7.41999157e-01 2.78139286 0.91649402 482.50 -6.13282897e-01 2.44678754e-01 6.60290545e-01 2.76197835 0.93430846 482.75 -4.96513456e-01 1.71335185e-01 5.25244093e-01 2.80931063 0.93967310 483.00 -4.69287734e-01 1.53155454e-01 4.93647213e-01 2.82613366 0.94583127 483.25 -3.89128479e-01 1.21755985e-01 4.07732134e-01 2.83834884 0.94092169 483.50 -3.64010830e-01 1.06671503e-01 3.79318723e-01 2.85652887 0.95763034 483.75 -3.17404433e-01 6.43297829e-02 3.23857832e-01 2.94162679 0.93337725 484.00 -2.88693079e-01 4.60140418e-02 2.92337110e-01 2.98353475 0.93200756 484.25 -2.61416602e-01 9.05292706e-03 2.61573308e-01 3.10697622 0.95306256 484.50 -2.59747925e-01 -7.83481965e-03 2.59866059e-01 -3.11143863 0.96569636 484.75 -2.59181189e-01 -2.03360612e-02 2.59977777e-01 -3.06329036 0.97812114 485.00 -2.54390190e-01 -2.91080881e-02 2.56050092e-01 -3.02766514 0.98221966 485.25 -2.36995390e-01 -3.67308750e-02 2.39824878e-01 -2.98783041 0.98522764 485.50 -2.31432817e-01 -4.03064966e-02 2.34916501e-01 -2.96916148 0.98703216 485.75 -2.26726470e-01 -4.33015957e-02 2.30824436e-01 -2.95287917 0.98758776 486.00 -2.20300418e-01 -4.82466189e-02 2.25521641e-01 -2.92599280 0.98339548 486.25 -2.10241816e-01 -4.69634458e-02 2.15423273e-01 -2.92182237 0.98573321 486.50 -1.95586125e-01 -4.87621916e-02 2.01573023e-01 -2.89726055 0.97592526 486.75 -1.72522391e-01 -5.18219725e-02 1.80137426e-01 -2.84978888 0.98313994 487.00 -1.64389686e-01 -5.67398225e-02 1.73906228e-01 -2.80924114 0.97527915 487.25 -1.44335158e-01 -7.16190042e-02 1.61127030e-01 -2.68099023 0.97230130 487.50 -1.33134073e-01 -7.70124258e-02 1.53803755e-01 -2.61716373 0.96319904 487.75 -1.19059301e-01 -8.89155280e-02 1.48597067e-01 -2.50013168 0.97812885 488.00 -1.11731245e-01 -9.89025464e-02 1.49216570e-01 -2.41702458 0.96937028 488.25 -1.05454587e-01 -1.08902916e-01 1.51593255e-01 -2.34010906 0.98003040 488.50 -9.47259488e-02 -1.15325148e-01 1.49241064e-01 -2.25843950 0.97773187 488.75 -8.17658627e-02 -1.19206033e-01 1.44553570e-01 -2.17201034 0.97718539 489.00 -6.58777753e-02 -1.21522271e-01 1.38230039e-01 -2.06755757 0.93867234 489.25 -4.42613262e-02 -1.29810543e-01 1.37148978e-01 -1.89940286 0.95003914 489.50 -2.10885610e-02 -1.36327325e-01 1.37948783e-01 -1.72427051 0.91678258 489.75 7.35765278e-03 -1.50084194e-01 1.50264435e-01 -1.52181204 0.93989818 490.00 2.63720660e-02 -1.67797184e-01 1.69856942e-01 -1.41490523 0.91340698 490.25 5.68759099e-02 -1.86354364e-01 1.94840494e-01 -1.27457301 0.94655210 490.50 8.35215521e-02 -2.09330747e-01 2.25377930e-01 -1.19115815 0.94069029 490.75 1.01281771e-01 -2.47310233e-01 2.67245857e-01 -1.18209872 0.95613371 491.00 1.27103795e-01 -2.85840572e-01 3.12826162e-01 -1.15238638 0.95068104 491.25 1.42331855e-01 -3.10629582e-01 3.41685666e-01 -1.14114057 0.96677404 491.50 1.69649746e-01 -3.37827166e-01 3.78032050e-01 -1.10540695 0.94811259 491.75 1.88601198e-01 -3.83980657e-01 4.27798500e-01 -1.11423466 0.94472546 492.00 2.18179743e-01 -4.73805810e-01 5.21626635e-01 -1.13925863 0.95749497 492.25 2.22087115e-01 -5.14784783e-01 5.60647893e-01 -1.16350266 0.96964694 492.50 1.97932017e-01 -5.94387655e-01 6.26477268e-01 -1.24934440 0.96917586 492.75 1.94447761e-01 -6.38444141e-01 6.67398571e-01 -1.27515671 0.97426184 493.00 1.95085746e-01 -7.05216365e-01 7.31702514e-01 -1.30091305 0.96936575 493.25 1.95617476e-01 -7.44022460e-01 7.69308532e-01 -1.31369626 0.96997394 493.50 1.66293219e-01 -8.78842738e-01 8.94437249e-01 -1.38378885 0.96287618 493.75 1.58546235e-01 -9.49149559e-01 9.62300262e-01 -1.40528413 0.96058955 494.00 2.84923233e-02 -1.11844111e+00 1.11880397e+00 -1.54532680 0.95264366 494.25 -4.81971268e-02 -1.19546893e+00 1.19644010e+00 -1.61109101 0.95147502 494.50 -2.30977988e-01 -1.37163597e+00 1.39094790e+00 -1.73762711 0.95312792 494.75 -3.84400253e-01 -1.37631461e+00 1.42898757e+00 -1.84315282 0.94842553 495.00 -6.49975726e-01 -1.31469872e+00 1.46659509e+00 -2.02994699 0.95594900 495.25 -8.01235833e-01 -1.27555999e+00 1.50633069e+00 -2.13165357 0.95542279 495.50 -9.63958363e-01 -1.11715825e+00 1.47555355e+00 -2.28271276 0.95659454 495.75 -1.06318914e+00 -9.96356886e-01 1.45708551e+00 -2.38863310 0.95596053 496.00 -1.16717202e+00 -7.37551786e-01 1.38067851e+00 -2.57803725 0.96828932 496.25 -1.16973644e+00 -6.12089419e-01 1.32020331e+00 -2.65950185 0.96136705 496.50 -1.08466134e+00 -4.32153891e-01 1.16758177e+00 -2.76244660 0.97697300 496.75 -1.06183735e+00 -3.66288519e-01 1.12323899e+00 -2.80941728 0.98133744 497.00 -1.02068195e+00 -2.61596419e-01 1.05367183e+00 -2.89069744 0.98494649 497.25 -9.69990690e-01 -2.27773967e-01 9.96374889e-01 -2.91095054 0.98248361 497.50 -8.71843090e-01 -1.55414322e-01 8.85586802e-01 -2.96518609 0.98341397 497.75 -8.29452306e-01 -1.30264034e-01 8.39618870e-01 -2.98581678 0.98027733 498.00 -7.72980369e-01 -1.04870348e-01 7.80061818e-01 -3.00674585 0.98355759 498.25 -7.30615836e-01 -1.01567412e-01 7.37641809e-01 -3.00346176 0.97860852 498.50 -6.77036289e-01 -8.90710045e-02 6.82870251e-01 -3.01078372 0.98186296 498.75 -6.39877042e-01 -7.99843084e-02 6.44856665e-01 -3.01723815 0.98072149 499.00 -5.96836299e-01 -7.95232343e-02 6.02110881e-01 -3.00913156 0.98750263 499.25 -5.82798456e-01 -7.64474204e-02 5.87790990e-01 -3.01116432 0.98406762 499.50 -5.68353195e-01 -6.52890908e-02 5.72090919e-01 -3.02721983 0.98971447 499.75 -5.54249759e-01 -5.12708777e-02 5.56616114e-01 -3.04935016 0.98730198 500.00 -5.24490172e-01 -3.93470260e-02 5.25964000e-01 -3.06671335 0.98845204 500.25 -4.84235754e-01 -1.92695388e-02 4.84619006e-01 -3.10181993 0.98026966 500.50 -4.53946179e-01 -5.57463759e-03 4.53980407e-01 -3.12931288 0.98452793 500.75 -4.19991415e-01 4.96160005e-03 4.20020721e-01 3.12977963 0.97354572 501.00 -3.78523096e-01 1.46429959e-02 3.78806219e-01 3.10292738 0.96080200 501.25 -3.17654466e-01 1.06647891e-02 3.17833443e-01 3.10803171 0.93566753 501.50 -2.71090689e-01 -1.44612563e-03 2.71094546e-01 -3.13625823 0.93940973 501.75 -2.18825964e-01 -3.59374140e-02 2.21757300e-01 -2.97881738 0.86066263 502.00 -1.74254174e-01 -5.32478674e-02 1.82208267e-01 -2.84502828 0.82216130 502.25 -1.26937592e-01 -8.29236885e-02 1.51622856e-01 -2.56292669 0.67083714 502.50 -8.82529752e-02 -9.39530187e-02 1.28902123e-01 -2.32492118 0.62269966 502.75 -5.87503558e-02 -1.42803975e-01 1.54416902e-01 -1.96109629 0.57767645 503.00 -2.33232879e-02 -1.86926702e-01 1.88376133e-01 -1.69492719 0.64292426 503.25 3.42327886e-03 -2.60996371e-01 2.61018820e-01 -1.55768089 0.66012746 503.50 2.70580577e-03 -3.48743161e-01 3.48753658e-01 -1.56303775 0.73980525 503.75 -2.89808908e-02 -3.77978908e-01 3.79088310e-01 -1.64731991 0.64500930 504.00 -3.52193974e-02 -4.10087539e-01 4.11597128e-01 -1.65646874 0.64216341 504.25 -1.08116256e-01 -4.74448870e-01 4.86611606e-01 -1.79484799 0.68349774 504.50 -1.26897972e-01 -5.38297335e-01 5.53052544e-01 -1.80230902 0.72730314 504.75 -2.49196421e-01 -5.51117749e-01 6.04838515e-01 -1.99544961 0.77623986 505.00 -2.88236581e-01 -5.32040560e-01 6.05101218e-01 -2.06728875 0.81837557 505.25 -3.00151457e-01 -4.98715360e-01 5.82072081e-01 -2.11257445 0.86205835 505.50 -2.86023570e-01 -5.30927203e-01 6.03069795e-01 -2.06494164 0.89754694 505.75 -2.97390112e-01 -5.49423842e-01 6.24745898e-01 -2.06691723 0.94094076 506.00 -3.09714260e-01 -5.77364323e-01 6.55188892e-01 -2.06315973 0.93629894 506.25 -3.49303374e-01 -6.28375103e-01 7.18935406e-01 -2.07814542 0.96544086 506.50 -4.00337249e-01 -6.36146127e-01 7.51632761e-01 -2.13249362 0.96698215 506.75 -4.91972129e-01 -6.33302511e-01 8.01940550e-01 -2.23125237 0.98218127 507.00 -5.11492662e-01 -6.24189350e-01 8.06992620e-01 -2.25728569 0.97941028 507.25 -6.00317978e-01 -5.52092490e-01 8.15590456e-01 -2.39801758 0.97925927 507.50 -6.05699081e-01 -5.12289255e-01 7.93291660e-01 -2.43955258 0.98240030 507.75 -5.82448605e-01 -4.64509442e-01 7.44993556e-01 -2.46837095 0.98822288 508.00 -5.88860448e-01 -4.28986530e-01 7.28550664e-01 -2.51199225 0.98571361 508.25 -5.96023915e-01 -3.91096602e-01 7.12882220e-01 -2.56088801 0.98733007 508.50 -5.95437682e-01 -3.60839286e-01 6.96240636e-01 -2.59676809 0.98508914 508.75 -6.11418550e-01 -3.06200923e-01 6.83806733e-01 -2.67730196 0.98821315 509.00 -5.93772794e-01 -2.59968365e-01 6.48189542e-01 -2.72890975 0.98144922 509.25 -5.76908002e-01 -2.05501400e-01 6.12416254e-01 -2.79939475 0.98535877 509.50 -5.30073781e-01 -1.70312281e-01 5.56762505e-01 -2.83071163 0.96592986 509.75 -4.76577429e-01 -1.11714390e-01 4.89495813e-01 -2.91134014 0.97666849 510.00 -4.23879064e-01 -8.77008149e-02 4.32856667e-01 -2.93757083 0.95552644 510.25 -3.67433644e-01 -6.38664109e-02 3.72942893e-01 -2.96949454 0.96555104 510.50 -3.19415066e-01 -5.16858584e-02 3.23569795e-01 -2.98116908 0.94777221 510.75 -2.61484249e-01 -5.65662967e-02 2.67532724e-01 -2.92854776 0.93773511 511.00 -2.13879796e-01 -7.22501446e-02 2.25753518e-01 -2.81582100 0.89454896 511.25 -1.55501469e-01 -9.55795334e-02 1.82527133e-01 -2.59046809 0.85719308 511.50 -1.08540964e-01 -1.11775727e-01 1.55804217e-01 -2.34151321 0.86290740 511.75 -8.61024829e-02 -1.30342683e-01 1.56214124e-01 -2.15457705 0.88263347 512.00 -3.66310128e-02 -1.58460193e-01 1.62639060e-01 -1.79797427 0.86829359 512.25 -1.39781712e-02 -1.77945701e-01 1.78493871e-01 -1.64918836 0.93230210 512.50 1.03574958e-02 -2.00743424e-01 2.01010447e-01 -1.51924635 0.90058868 512.75 5.14210545e-02 -2.33205835e-01 2.38807634e-01 -1.35377256 0.93536561 513.00 9.08830969e-02 -2.52146306e-01 2.68025179e-01 -1.22485310 0.92562197 513.25 1.29899836e-01 -2.76302612e-01 3.05314757e-01 -1.13132396 0.94968720 513.50 1.58749203e-01 -3.32068066e-01 3.68063188e-01 -1.12485245 0.95556947 513.75 1.90988497e-01 -3.66639550e-01 4.13401942e-01 -1.09055608 0.95869223 514.00 2.25644495e-01 -4.37643575e-01 4.92389416e-01 -1.09475493 0.96082641 514.25 2.29049457e-01 -4.99741782e-01 5.49732210e-01 -1.14103216 0.96317015 514.50 2.58212312e-01 -5.82862126e-01 6.37496554e-01 -1.15377253 0.96679558 514.75 2.49673495e-01 -6.43963811e-01 6.90670865e-01 -1.20092638 0.97029957 515.00 1.98995391e-01 -7.38882060e-01 7.65209686e-01 -1.30771881 0.96650504 515.25 1.35216378e-01 -7.96428786e-01 8.07825650e-01 -1.40262159 0.96147807 515.50 1.26374786e-02 -8.40873764e-01 8.40968723e-01 -1.55576847 0.96666052 515.75 -7.26613696e-02 -8.45607049e-01 8.48723133e-01 -1.65651383 0.96078993 516.00 -1.92616720e-01 -7.55190355e-01 7.79367483e-01 -1.82052899 0.95841512 516.25 -2.24917128e-01 -6.90234407e-01 7.25955405e-01 -1.88580239 0.95158063 516.50 -1.96960223e-01 -5.52955013e-01 5.86986010e-01 -1.91298004 0.91141224 516.75 -1.22364728e-01 -4.87179848e-01 5.02311986e-01 -1.81687541 0.88220872 517.00 5.62485479e-02 -4.57221868e-01 4.60668792e-01 -1.44838894 0.82628810 517.25 1.63087342e-01 -4.98793213e-01 5.24778192e-01 -1.25478923 0.84017996 517.50 2.70331693e-01 -6.32278291e-01 6.87644575e-01 -1.16676631 0.92364254 517.75 2.63800660e-01 -7.08100574e-01 7.55643574e-01 -1.21417807 0.92995252 518.00 1.49714134e-01 -8.18121374e-01 8.31707223e-01 -1.38980152 0.92826616 518.25 5.33537708e-03 -8.72095096e-01 8.72111416e-01 -1.56467852 0.91644821 518.50 -1.08360472e-01 -7.05142649e-01 7.13420035e-01 -1.72327523 0.85046282 518.75 -8.34607677e-02 -5.58431973e-01 5.64634366e-01 -1.71915378 0.87806229 519.00 -6.25523569e-03 -5.45715515e-01 5.45751364e-01 -1.58225827 0.86070055 519.25 1.22339207e-01 -5.39251843e-01 5.52955180e-01 -1.34770422 0.85346204 519.50 1.94592370e-01 -5.40184357e-01 5.74164898e-01 -1.22503427 0.91844636 519.75 2.00378657e-01 -5.49495785e-01 5.84890779e-01 -1.22112230 0.90928239 520.00 2.01570192e-01 -5.14414501e-01 5.52496897e-01 -1.19734077 0.91969421 520.25 2.74724326e-01 -4.35520796e-01 5.14928946e-01 -1.00804069 0.89182841 520.50 3.74852242e-01 -3.60355887e-01 5.19971699e-01 -0.76568337 0.91283101 520.75 4.36753972e-01 -3.48601035e-01 5.58817245e-01 -0.67362006 0.89731867 521.00 5.10627943e-01 -3.51052647e-01 6.19660276e-01 -0.60228194 0.90692674 521.25 5.38628661e-01 -2.38331244e-01 5.89001372e-01 -0.41658091 0.82440264 521.50 6.81984663e-01 -1.40930352e-01 6.96393886e-01 -0.20377904 0.88364472 521.75 7.59513492e-01 -8.96294682e-02 7.64783751e-01 -0.11746578 0.90353205 522.00 8.16381606e-01 -2.12345110e-02 8.16657720e-01 -0.02600466 0.92086613 522.25 9.41526556e-01 1.32542715e-01 9.50810090e-01 0.13985525 0.87587861 522.50 1.06725603e+00 2.66653559e-01 1.10006343e+00 0.24483716 0.89687349 522.75 1.13833142e+00 5.28729705e-01 1.25513088e+00 0.43482825 0.88276291 523.00 1.13819064e+00 7.30512311e-01 1.35245191e+00 0.57060252 0.87221011 523.25 1.36199503e+00 8.49298959e-01 1.60509787e+00 0.55757019 0.78639120 523.50 1.74700948e+00 8.76862103e-01 1.95471974e+00 0.46518385 0.80709800 523.75 1.61103896e+00 7.44904573e-01 1.77491672e+00 0.43309741 0.79369275 524.00 1.61526780e+00 7.73650296e-01 1.79098432e+00 0.44667520 0.82471453 524.25 1.37629965e+00 7.40761313e-01 1.56298690e+00 0.49375935 0.88839310 524.50 1.31916038e+00 7.60730778e-01 1.52279198e+00 0.52309443 0.92216273 524.75 1.12945923e+00 8.92527563e-01 1.43954285e+00 0.66875244 0.84275472 525.00 1.14898577e+00 8.10871270e-01 1.40630029e+00 0.61455983 0.78388001 525.25 1.01284339e+00 4.03795294e-02 1.01364798e+00 0.03984639 0.68885631 525.50 8.60938357e-01 -4.21224409e-03 8.60948661e-01 -0.00489258 0.77673109 525.75 5.29269440e-01 -5.53993847e-03 5.29298433e-01 -0.01046676 0.72901283 526.00 4.03309661e-01 8.45316947e-03 4.03398239e-01 0.02095643 0.66169029 526.25 1.47501623e-01 3.79732394e-02 1.52311181e-01 0.25197135 0.36643499 526.50 7.42257864e-02 7.45238136e-02 1.05182062e-01 0.78740171 0.25997145 526.75 1.06460025e-04 1.75165807e-01 1.75165839e-01 1.57018856 0.54350158 527.00 -4.86417275e-02 1.79446850e-01 1.85922536e-01 1.83550036 0.65914861 527.25 -9.53948911e-02 2.23498342e-01 2.43005544e-01 1.97421255 0.76937979 527.50 -1.07604684e-01 2.42974222e-01 2.65735283e-01 1.98770064 0.80066388 527.75 -1.00190781e-01 2.76421903e-01 2.94019151e-01 1.91852444 0.84148957 528.00 -7.59333731e-02 2.74641631e-01 2.84945438e-01 1.84053950 0.81201802 528.25 -1.30250655e-02 2.41348013e-01 2.41699226e-01 1.62471201 0.83864682 528.50 2.17517735e-02 1.94141873e-01 1.95356613e-01 1.45922104 0.75578714 528.75 5.35388479e-02 1.17115327e-01 1.28772699e-01 1.14201538 0.68142705 529.00 4.83153688e-02 8.37210894e-02 9.66622763e-02 1.04738592 0.44184220 529.25 3.20538563e-02 9.18236688e-04 3.20670058e-02 0.02863885 0.06502261 529.50 2.75032725e-02 -4.15467205e-02 4.98252947e-02 -0.98604244 0.13782173 529.75 8.78911210e-03 -7.90223474e-02 7.95096213e-02 -1.46002846 0.36554274 530.00 1.19195873e-02 -9.45810332e-02 9.53291582e-02 -1.44543210 0.37240204 530.25 2.23735722e-02 -1.45085129e-01 1.46800107e-01 -1.41779162 0.48914782 530.50 1.22232905e-02 -1.93626389e-01 1.94011823e-01 -1.50775176 0.57140140 530.75 4.50904599e-03 -2.54765673e-01 2.54805572e-01 -1.55309938 0.71420234 531.00 -2.98427537e-02 -2.92937484e-01 2.94453663e-01 -1.67232022 0.74219120 531.25 -9.58776459e-02 -3.47595097e-01 3.60575754e-01 -1.83993533 0.86457536 531.50 -1.74583877e-01 -3.71141360e-01 4.10152946e-01 -2.01048254 0.84520903 531.75 -2.48819547e-01 -3.85839124e-01 4.59111094e-01 -2.14356312 0.88033516 532.00 -2.92520328e-01 -3.17972409e-01 4.32058555e-01 -2.31452757 0.83463533 532.25 -3.17333216e-01 -2.87814462e-01 4.28412808e-01 -2.40493528 0.88108006 532.50 -3.47689309e-01 -2.40265309e-01 4.22629003e-01 -2.53690918 0.84167335 532.75 -3.61634024e-01 -2.28872970e-01 4.27974303e-01 -2.57734287 0.86905749 533.00 -3.62206574e-01 -1.89923225e-01 4.08979747e-01 -2.65865489 0.84533740 533.25 -3.75155091e-01 -1.60210712e-01 4.07932365e-01 -2.73798527 0.86542804 533.50 -3.56057381e-01 -8.91088435e-02 3.67038478e-01 -2.89636422 0.76688491 533.75 -3.26428069e-01 -5.51999790e-02 3.31062414e-01 -2.97407439 0.72214467 534.00 -3.13518556e-01 1.35794444e-02 3.13812502e-01 3.09830666 0.71778816 534.25 -2.56202263e-01 5.81873484e-02 2.62726792e-01 2.91826614 0.69534283 534.50 -1.59724280e-01 9.54847650e-02 1.86089189e-01 2.60278504 0.48767079 534.75 -9.59167631e-02 9.28542080e-02 1.33498799e-01 2.37241672 0.36121609 535.00 -1.27230809e-02 5.36272525e-02 5.51158689e-02 1.80373973 0.07216248 535.25 5.96027447e-02 3.88816699e-02 7.11636946e-02 0.57802334 0.12630749 535.50 1.25225477e-01 -4.74468529e-02 1.33912748e-01 -0.36217791 0.32475492 535.75 1.53632847e-01 -1.08840917e-01 1.88280102e-01 -0.61637344 0.52595949 536.00 2.13983712e-01 -2.07726626e-01 2.98227062e-01 -0.77056185 0.70418636 536.25 2.53206347e-01 -2.78065350e-01 3.76076845e-01 -0.83215557 0.77352439 536.50 1.85960910e-01 -4.13791396e-01 4.53657116e-01 -1.14843533 0.76269946 536.75 1.38745257e-01 -4.90127369e-01 5.09386969e-01 -1.29493383 0.82618678 537.00 5.61651618e-02 -5.28053619e-01 5.31032155e-01 -1.46483211 0.81644182 537.25 -1.65709511e-02 -5.20185378e-01 5.20449252e-01 -1.60264141 0.77483444 537.50 -2.09426748e-01 -5.18517267e-01 5.59213482e-01 -1.95465630 0.81610687 537.75 -2.52708576e-01 -4.60075683e-01 5.24910715e-01 -2.07308359 0.85225158 538.00 -2.43235325e-01 -3.60632626e-01 4.34993465e-01 -2.16418073 0.90240737 538.25 -1.91391102e-01 -3.30940566e-01 3.82298591e-01 -2.09512561 0.87654916 538.50 -1.76191507e-01 -3.23780997e-01 3.68615764e-01 -2.06915157 0.91478512 538.75 -1.81862398e-01 -3.07874086e-01 3.57575705e-01 -2.10435236 0.92133929 539.00 -1.80436117e-01 -2.71837190e-01 3.26270824e-01 -2.15678766 0.94689217 539.25 -1.61153562e-01 -2.59127155e-01 3.05151361e-01 -2.12716996 0.93645987 539.50 -1.26339972e-01 -2.48321850e-01 2.78613585e-01 -2.04143934 0.93347197 539.75 -1.01678371e-01 -2.45448520e-01 2.65675492e-01 -1.96353111 0.90022732 540.00 -5.79973053e-02 -2.40213462e-01 2.47115752e-01 -1.80770309 0.86422571 540.25 -4.10755582e-02 -2.33813879e-01 2.37394464e-01 -1.74469813 0.85324257 540.50 -2.68551470e-02 -2.39631163e-01 2.41131278e-01 -1.68239934 0.91379163 540.75 -7.20473402e-03 -2.49819250e-01 2.49923120e-01 -1.59962812 0.90186389 541.00 2.47208882e-03 -2.63701891e-01 2.63713478e-01 -1.56142204 0.91320158 541.25 1.46518745e-02 -2.40939377e-01 2.41384467e-01 -1.51005967 0.86281435 541.50 2.94440694e-02 -2.14597559e-01 2.16608092e-01 -1.43444174 0.82850277 541.75 5.95503466e-02 -2.12207027e-01 2.20404324e-01 -1.29720925 0.80565057 542.00 8.83939780e-02 -2.02983028e-01 2.21394681e-01 -1.16008705 0.80772637 542.25 1.12357157e-01 -1.99911422e-01 2.29322279e-01 -1.05876040 0.73356720 542.50 1.44673202e-01 -1.95653570e-01 2.43332395e-01 -0.93409083 0.71919438 542.75 2.40231528e-01 -1.74222348e-01 2.96756826e-01 -0.62745685 0.74974164 543.00 3.06854001e-01 -1.49584715e-01 3.41372179e-01 -0.45358029 0.79047502 543.25 3.70167323e-01 -1.54161487e-01 4.00985799e-01 -0.39461870 0.78335068 543.50 4.40624572e-01 -1.73546987e-01 4.73570027e-01 -0.37520719 0.84034902 543.75 5.60591888e-01 -2.67214592e-01 6.21020856e-01 -0.44480604 0.88045175 544.00 5.91830748e-01 -3.41636581e-01 6.83358755e-01 -0.52352646 0.92978099 544.25 5.96634398e-01 -3.69856179e-01 7.01973074e-01 -0.55492654 0.85414427 544.50 6.55159708e-01 -4.16730884e-01 7.76465629e-01 -0.56652394 0.91147501 544.75 7.46694581e-01 -4.24578946e-01 8.58964539e-01 -0.51701972 0.90917030 545.00 8.03516540e-01 -4.28392535e-01 9.10581679e-01 -0.48981235 0.90285799 545.25 8.54740393e-01 -4.57430548e-01 9.69445122e-01 -0.49138538 0.92206391 545.50 9.45941785e-01 -4.76770641e-01 1.05929982e+00 -0.46685596 0.92387428 545.75 9.96793237e-01 -4.94466455e-01 1.11269665e+00 -0.46048839 0.90345944 546.00 1.02332453e+00 -4.79172720e-01 1.12995557e+00 -0.43792736 0.90589326 546.25 1.22765256e+00 -5.09350949e-01 1.32912347e+00 -0.39328339 0.87693573 546.50 1.33629687e+00 -4.82977495e-01 1.42089993e+00 -0.34682075 0.86430976 546.75 1.56894990e+00 -4.04727289e-01 1.62031107e+00 -0.25245686 0.82706945 547.00 1.65422316e+00 -3.67666492e-01 1.69458931e+00 -0.21870428 0.76432144 547.25 2.22036609e+00 -3.40650752e-01 2.24634559e+00 -0.15223396 0.78208489 547.50 2.42883042e+00 -5.47281551e-01 2.48972575e+00 -0.22162585 0.76082039 547.75 2.80726947e+00 -6.10637397e-01 2.87291488e+00 -0.21418362 0.64480202 548.00 2.59176376e+00 -8.38885316e-01 2.72414536e+00 -0.31303168 0.58028750 548.25 1.80578309e+00 -1.39709564e+00 2.28314012e+00 -0.65848396 0.50516036 548.50 1.63931032e+00 -1.62758214e+00 2.31005670e+00 -0.78180817 0.52473174 548.75 1.99866841e+00 -1.73541992e+00 2.64695253e+00 -0.71501588 0.59573569 549.00 2.20721687e+00 -1.57410395e+00 2.71101633e+00 -0.61950524 0.60920160 549.25 2.72080588e+00 -1.48241818e+00 3.09844289e+00 -0.49887702 0.62279605 549.50 2.54105729e+00 -1.17843202e+00 2.80101306e+00 -0.43423482 0.54469067 549.75 2.87773796e+00 -8.59542529e-01 3.00336297e+00 -0.29025165 0.63707045 550.00 3.04194811e+00 -9.00723579e-01 3.17249922e+00 -0.28787581 0.60121741 550.25 3.02742252e+00 -1.13614383e+00 3.23359087e+00 -0.35901981 0.65192514 550.50 2.71968288e+00 -1.11714948e+00 2.94018671e+00 -0.38975163 0.64531680 550.75 2.75828546e+00 -1.06056849e+00 2.95515553e+00 -0.36707576 0.67231761 551.00 2.12338344e+00 -1.07003125e+00 2.37775611e+00 -0.46678465 0.66674092 551.25 1.67602215e+00 -7.10368102e-01 1.82034972e+00 -0.40088916 0.63675834 551.50 1.36705841e+00 -4.82684979e-01 1.44977015e+00 -0.33941865 0.55627123 551.75 1.02783298e+00 -2.53497206e-01 1.05863189e+00 -0.24180692 0.50257825 552.00 8.09251477e-01 -1.29960246e-01 8.19620411e-01 -0.15923356 0.49155009 552.25 7.13411942e-01 3.76220063e-02 7.14403258e-01 0.05268651 0.56718528 552.50 5.93307294e-01 1.27523284e-01 6.06857259e-01 0.21171529 0.45250684 552.75 3.48882446e-01 3.79753529e-01 5.15685664e-01 0.82774116 0.43044325 553.00 3.38335339e-01 4.27363052e-01 5.45077958e-01 0.90114838 0.40573337 553.25 3.27946327e-01 5.27803819e-01 6.21390107e-01 1.01483229 0.45247344 553.50 4.80777966e-01 4.33431993e-01 6.47310393e-01 0.73365544 0.48129710 553.75 5.33557232e-01 4.49012852e-01 6.97349168e-01 0.69956545 0.54308033 554.00 5.97443909e-01 2.72655568e-01 6.56719334e-01 0.42813870 0.59874121 554.25 5.15028812e-01 1.85242205e-01 5.47329290e-01 0.34526649 0.54787721 554.50 4.05119391e-01 2.90090007e-01 4.98270944e-01 0.62142372 0.62195738 554.75 3.35421172e-01 2.96764870e-01 4.47857958e-01 0.72432717 0.63516363 555.00 2.55514699e-01 2.49413190e-01 3.57064001e-01 0.77331483 0.44454784 555.25 1.70169717e-01 3.63169585e-01 4.01060943e-01 1.13260883 0.42097337 555.50 9.97617916e-02 5.53025195e-01 5.61951316e-01 1.39232289 0.52896723 555.75 1.30438331e-01 6.33743731e-01 6.47028033e-01 1.36780912 0.52231731 556.00 1.42024617e-01 7.16120129e-01 7.30067826e-01 1.37501174 0.48725844 556.25 1.89100390e-01 6.75105770e-01 7.01089694e-01 1.29769041 0.42519018 556.50 2.71427790e-01 5.19873432e-01 5.86465199e-01 1.08962260 0.32709184 556.75 3.76233528e-01 4.20161447e-01 5.63992295e-01 0.84050078 0.27698179 557.00 5.13539463e-01 3.99169331e-01 6.50429808e-01 0.66073947 0.21331743 557.25 6.46912106e-01 2.74565739e-01 7.02767115e-01 0.40138361 0.23410535 557.50 5.55668557e-01 -2.39683039e-01 6.05157421e-01 -0.40722987 0.29466716 557.75 5.86239856e-01 -3.33226282e-01 6.74327016e-01 -0.51686979 0.37101226 558.00 6.18192000e-01 -5.18521915e-01 8.06862024e-01 -0.69793919 0.48151985 558.25 4.19390979e-01 -5.49668156e-01 6.91392707e-01 -0.91903370 0.51301520 558.50 6.01527947e-02 -4.96678944e-01 5.00308237e-01 -1.45027329 0.50224153 558.75 5.26684574e-02 -3.03694412e-01 3.08227614e-01 -1.39907845 0.36623255 559.00 4.53493050e-02 -2.11879372e-01 2.16678166e-01 -1.35994405 0.31760011 559.25 3.73024373e-02 -1.37390659e-01 1.42364550e-01 -1.30568102 0.17163804 559.50 -5.24292725e-03 -3.43079733e-02 3.47062720e-02 -1.72244258 0.01826765 559.75 -2.12318195e-02 -4.51985336e-03 2.17075847e-02 -2.93184264 0.00600146 560.00 -5.97978386e-02 1.22017032e-02 6.10300177e-02 2.94030665 0.04501882 560.25 -4.49446956e-02 8.60093843e-02 9.70445250e-02 2.05232526 0.09694779 560.50 4.59318615e-02 2.09303239e-01 2.14283881e-01 1.35476948 0.27897877 560.75 1.22451813e-01 3.27039779e-01 3.49212634e-01 1.21253001 0.46109523 561.00 2.83726865e-01 4.09403407e-01 4.98108506e-01 0.96476681 0.61420335 561.25 4.53719389e-01 2.60795348e-01 5.23331155e-01 0.52167973 0.56769768 561.50 5.33005365e-01 8.42413034e-02 5.39621456e-01 0.15675300 0.56642457 561.75 4.21662893e-01 -6.99339010e-02 4.27422912e-01 -0.16435654 0.38048276 562.00 3.16988743e-01 -3.39746255e-01 4.64660500e-01 -0.82003681 0.49849077 562.25 1.83908349e-01 -4.12643351e-01 4.51770756e-01 -1.15153777 0.47718510 562.50 2.78408791e-02 -4.14772386e-01 4.15705721e-01 -1.50377359 0.48845446 562.75 -1.27927681e-01 -2.97790078e-01 3.24105573e-01 -1.97654843 0.32865268 563.00 -2.72649343e-01 -2.21601940e-01 3.51347526e-01 -2.45911186 0.42202755 563.25 -3.56589190e-01 -9.85417512e-02 3.69954494e-01 -2.87197615 0.47242338 563.50 -3.81503499e-01 8.00962070e-03 3.81587570e-01 3.12060086 0.57354154 563.75 -3.21421488e-01 1.82371204e-01 3.69555177e-01 2.62549661 0.51257062 564.00 -2.60729632e-01 3.20019570e-01 4.12786223e-01 2.25445483 0.64444834 564.25 -2.03637020e-01 3.42150235e-01 3.98164312e-01 2.10765563 0.65260789 564.50 -1.67498690e-01 3.79570043e-01 4.14884597e-01 1.98637954 0.68109066 564.75 -1.02931500e-01 3.43372169e-01 3.58468046e-01 1.86203896 0.70474852 565.00 -7.78347504e-02 3.42256437e-01 3.50995324e-01 1.79440961 0.76707996 565.25 -5.28781586e-02 3.28838678e-01 3.33063021e-01 1.73023419 0.66172162 565.50 -1.98006848e-02 3.52368346e-01 3.52924239e-01 1.62693043 0.70293398 565.75 -4.54344539e-03 3.97990941e-01 3.98016874e-01 1.58221178 0.72004763 566.00 3.86250838e-02 4.05915855e-01 4.07749407e-01 1.47592658 0.71767453 566.25 1.23992274e-01 4.15145984e-01 4.33266976e-01 1.28055878 0.80126878 566.50 1.66860541e-01 4.08721795e-01 4.41470210e-01 1.18319845 0.83380153 566.75 2.26708847e-01 3.50684102e-01 4.17583813e-01 0.99690244 0.84581618 567.00 2.65159041e-01 2.84586356e-01 3.88971350e-01 0.82072221 0.80626765 567.25 2.88395237e-01 1.82556390e-01 3.41318983e-01 0.56433691 0.77414998 567.50 2.74385459e-01 1.65651076e-01 3.20511558e-01 0.54314787 0.74551694 567.75 2.48114668e-01 1.43899647e-02 2.48531607e-01 0.05793234 0.61561562 568.00 2.19240321e-01 -4.92103029e-02 2.24695288e-01 -0.22079876 0.58466050 568.25 6.83276573e-02 -1.02525419e-01 1.23207672e-01 -0.98294650 0.30683593 568.50 2.23699090e-03 -9.79773991e-02 9.80029329e-02 -1.54796859 0.25390231 568.75 -1.00571577e-01 2.87729021e-02 1.04606510e-01 2.86294218 0.29305220 569.00 -9.21062030e-02 9.71952871e-02 1.33904729e-01 2.32931748 0.42627107 569.25 -4.05668513e-02 1.97241405e-01 2.01369912e-01 1.77363885 0.61390917 569.50 3.50749319e-02 2.03499355e-01 2.06499972e-01 1.40011439 0.57705783 569.75 1.23402337e-01 1.69029071e-01 2.09282020e-01 0.94017567 0.53865176 570.00 1.46794011e-01 9.38042142e-02 1.74205948e-01 0.56861719 0.35697964 570.25 1.24972007e-01 -6.52982783e-02 1.41003077e-01 -0.48148770 0.30192782 570.50 3.80427543e-02 -1.04942303e-01 1.11624989e-01 -1.22301949 0.17060868 570.75 -1.07872048e-01 -1.47842595e-01 1.83013147e-01 -2.20113998 0.36673012 571.00 -1.54423624e-01 -1.08619107e-01 1.88798215e-01 -2.52859916 0.35465307 571.25 -2.40293968e-01 -5.79802618e-02 2.47190012e-01 -2.90482935 0.44807140 571.50 -2.65316416e-01 -2.87609587e-03 2.65332004e-01 -3.13075283 0.44937838 571.75 -2.92564393e-01 3.07360174e-02 2.94174484e-01 3.03691935 0.60522404 572.00 -3.01590118e-01 6.23131470e-02 3.07960270e-01 2.93784435 0.56575473 572.25 -3.18719052e-01 9.04061617e-02 3.31293085e-01 2.86519816 0.68338176 572.50 -2.91189796e-01 7.16892537e-02 2.99884721e-01 2.90019907 0.63756508 572.75 -2.84865672e-01 1.05909788e-01 3.03916657e-01 2.78564049 0.68318338 573.00 -2.96024678e-01 1.53602942e-01 3.33503334e-01 2.66295097 0.64089866 573.25 -2.89755364e-01 1.81672835e-01 3.41998815e-01 2.58156579 0.55829261 573.50 -9.02519806e-02 1.77028114e-01 1.98706752e-01 2.04226683 0.14908845 573.75 7.48408279e-02 1.10538847e-02 7.56527454e-02 0.14663842 0.03872714 574.00 5.29137537e-02 -1.35846661e-01 1.45788136e-01 -1.19936486 0.20099586 574.25 2.39788626e-02 -2.17591583e-01 2.18908846e-01 -1.46103797 0.44352781 574.50 -6.15300767e-02 -2.79881116e-01 2.86564808e-01 -1.78719746 0.60015981 574.75 -1.21227196e-01 -3.14862434e-01 3.37393517e-01 -1.93831944 0.64209263 575.00 -2.55133035e-01 -3.59500094e-01 4.40832375e-01 -2.18799500 0.65243727 575.25 -3.64856137e-01 -4.18077869e-01 5.54895581e-01 -2.28832162 0.72861073 575.50 -5.02263687e-01 -3.09300294e-01 5.89860562e-01 -2.58962732 0.70009531 575.75 -5.60708205e-01 -2.72727958e-01 6.23517626e-01 -2.68888486 0.78255938 576.00 -5.92279276e-01 -1.75364467e-01 6.17695262e-01 -2.85373230 0.73034851 576.25 -6.69013729e-01 -8.27837440e-02 6.74116101e-01 -3.01847849 0.78600567 576.50 -5.77186183e-01 -5.90861026e-02 5.80202600e-01 -3.03957879 0.76900060 576.75 -4.71017992e-01 -6.05293738e-02 4.74891307e-01 -3.01378556 0.72087774 577.00 -3.51997428e-01 -1.57046292e-01 3.85442249e-01 -2.72193874 0.67178861 577.25 -2.81555556e-01 -1.85476286e-01 3.37157209e-01 -2.55908699 0.48888466 577.50 -5.45303167e-02 -1.77493410e-01 1.85681087e-01 -1.86886782 0.16560729 577.75 2.11817778e-02 -1.61149876e-01 1.62535997e-01 -1.44010406 0.15429293 578.00 1.87226511e-01 -1.36351006e-01 2.31614687e-01 -0.62944670 0.18658743 578.25 2.90467992e-01 -1.19935948e-01 3.14255129e-01 -0.39158241 0.24721644 578.50 5.22377521e-01 -7.98141981e-04 5.22378130e-01 -0.00152790 0.56555190 578.75 5.96022114e-01 1.26787285e-01 6.09358167e-01 0.20959822 0.70304519 579.00 7.12947388e-01 3.37180282e-01 7.88659952e-01 0.44176501 0.81313045 579.25 6.88505352e-01 4.14482326e-01 8.03638736e-01 0.54189103 0.78293233 579.50 6.16878968e-01 4.83435734e-01 7.83740882e-01 0.66471023 0.81761527 579.75 5.86158950e-01 5.74524348e-01 8.20768263e-01 0.77537457 0.82673476 580.00 4.09697559e-01 6.97357346e-01 8.08801186e-01 1.03961858 0.82510297 580.25 3.28535208e-01 7.50811291e-01 8.19544372e-01 1.15832410 0.82137715 580.50 2.72921193e-01 7.65730309e-01 8.12913823e-01 1.22841409 0.88616310 580.75 2.31292971e-01 7.94333487e-01 8.27322263e-01 1.28745201 0.85470665 581.00 1.04568411e-01 9.51258201e-01 9.56988358e-01 1.46130950 0.84004317 581.25 2.97624580e-02 9.20385510e-01 9.20866598e-01 1.53847064 0.81949735 581.50 -2.52917355e-02 9.43706030e-01 9.44044884e-01 1.59759035 0.82029293 581.75 -9.87543978e-02 9.41125555e-01 9.46292630e-01 1.67534595 0.81822342 582.00 -2.27525310e-01 9.34839160e-01 9.62128901e-01 1.80953896 0.84536485 582.25 -2.00938142e-01 9.20863566e-01 9.42531614e-01 1.78563500 0.80109532 582.50 -1.11264742e-01 8.85147142e-01 8.92112832e-01 1.69584243 0.73117571 582.75 -1.90110816e-01 7.20810046e-01 7.45459084e-01 1.82867004 0.57061644 583.00 -2.69233476e-01 6.96929771e-01 7.47126342e-01 1.93944873 0.52963495 583.25 -2.60386682e-01 4.66315925e-01 5.34089661e-01 2.08005904 0.28319664 583.50 -3.83344754e-01 2.35195829e-01 4.49744681e-01 2.59127958 0.21019439 583.75 -5.56821502e-03 2.57435805e-01 2.57496017e-01 1.59242248 0.08303501 584.00 2.27189304e-01 2.99278382e-01 3.75742637e-01 0.92148159 0.19376525 584.25 3.16271308e-01 1.78006878e-01 3.62924219e-01 0.51263986 0.19247918 584.50 3.39997294e-01 1.18177331e-01 3.59950054e-01 0.33452010 0.25554101 584.75 3.57704007e-01 1.26186442e-01 3.79308812e-01 0.33913840 0.34585208 585.00 4.23003489e-01 1.12495578e-01 4.37706759e-01 0.25992833 0.45917514 585.25 3.85861404e-01 1.11106319e-01 4.01539086e-01 0.28035950 0.35128726 585.50 3.70898684e-01 4.65476310e-02 3.73808127e-01 0.12484686 0.33787775 585.75 3.28073792e-01 -4.16696437e-02 3.30709498e-01 -0.12633655 0.33867777 586.00 3.46446589e-01 -8.26942143e-02 3.56179130e-01 -0.23430836 0.37467234 586.25 2.78426912e-01 -1.97361975e-01 3.41281841e-01 -0.61663865 0.38105585 586.50 3.15875240e-01 -2.81891175e-01 4.23367219e-01 -0.72860755 0.50876318 586.75 3.18162694e-01 -3.05306418e-01 4.40952955e-01 -0.76478054 0.53748327 587.00 3.19846201e-01 -3.79747030e-01 4.96497129e-01 -0.87081221 0.63903562 587.25 2.72474680e-01 -4.95293394e-01 5.65294611e-01 -1.06785498 0.70728755 587.50 2.02050391e-01 -5.08046916e-01 5.46750427e-01 -1.19227405 0.73935615 587.75 9.29699041e-02 -4.91275301e-01 4.99994825e-01 -1.38376610 0.70535877 588.00 5.40646314e-02 -4.62247808e-01 4.65398775e-01 -1.45436504 0.63777091 588.25 -1.09140215e-02 -3.23152204e-01 3.23336454e-01 -1.60455712 0.48256004 588.50 -8.80110546e-03 -2.72901519e-01 2.73043400e-01 -1.60303527 0.47110872 588.75 3.55201476e-02 -1.86912161e-01 1.90257291e-01 -1.38299908 0.36702392 589.00 6.12381869e-02 -1.47665966e-01 1.59860418e-01 -1.17767570 0.23445394 589.25 1.00582026e-01 -8.01534303e-02 1.28613049e-01 -0.67284549 0.10098257 589.50 6.62849275e-02 1.00681974e-02 6.70452103e-02 0.15074049 0.02237342 589.75 -2.80097082e-02 1.24705486e-01 1.27812370e-01 1.79173655 0.12048846 590.00 -3.09005482e-02 1.38082112e-01 1.41497398e-01 1.79095293 0.18052034 590.25 2.02003942e-02 1.43714139e-01 1.45126875e-01 1.43115164 0.21634130 590.50 8.63312583e-02 1.23912388e-01 1.51021078e-01 0.96228043 0.22697012 590.75 2.17774661e-01 1.05684122e-01 2.42063910e-01 0.45181146 0.47138441 591.00 2.78075484e-01 8.10318663e-02 2.89641396e-01 0.28355055 0.52409389 591.25 4.44761882e-01 3.65724694e-03 4.44776918e-01 0.00822275 0.74930469 591.50 4.91452554e-01 -1.05195235e-01 5.02584968e-01 -0.21086760 0.78108460 591.75 5.61266460e-01 -2.05950660e-01 5.97859275e-01 -0.35168500 0.85906843 592.00 5.49939509e-01 -2.59247029e-01 6.07982308e-01 -0.44051521 0.81378863 592.25 5.47853269e-01 -4.21618257e-01 6.91306849e-01 -0.65591653 0.75571553 592.50 4.59337012e-01 -6.07421392e-01 7.61545297e-01 -0.92333382 0.64274369 592.75 2.52420453e-01 -9.12013399e-01 9.46300441e-01 -1.30078276 0.73409134 593.00 -1.55560791e-02 -9.03681756e-01 9.03815638e-01 -1.58800874 0.61971333 593.25 -3.69695061e-01 -6.87540493e-01 7.80632031e-01 -2.06415226 0.49262861 593.50 -4.19449883e-01 -2.44072678e-01 4.85293392e-01 -2.61459758 0.37870543 593.75 -4.45248381e-01 -1.17078841e-02 4.45402285e-01 -3.11530354 0.65735291 594.00 -3.15338109e-01 2.29041275e-02 3.16168819e-01 3.06908643 0.68353677 594.25 -2.33084090e-01 5.20816884e-03 2.33142270e-01 3.11925178 0.68505175 594.50 -1.72738584e-01 9.46051693e-03 1.72997456e-01 3.08687949 0.59304320 594.75 -1.44224461e-01 1.58232168e-02 1.45089866e-01 3.03231726 0.55504156 595.00 -1.28239998e-01 2.24223491e-02 1.30185478e-01 2.96849567 0.53397620 595.25 -1.03790050e-01 5.78249179e-02 1.18811176e-01 2.63328914 0.48662918 595.50 -2.99623950e-02 1.13486830e-01 1.17375490e-01 1.82892286 0.44393299 595.75 3.48278155e-02 1.22990855e-01 1.27826942e-01 1.29484678 0.54919257 596.00 9.97570593e-02 8.93949877e-02 1.33951240e-01 0.73067116 0.57416504 596.25 1.39724097e-01 7.68962012e-02 1.59486204e-01 0.50310664 0.68086313 596.50 1.97531510e-01 4.26659496e-02 2.02086814e-01 0.21272764 0.74862204 596.75 2.33309989e-01 -3.10634258e-03 2.33330668e-01 -0.01331344 0.83334425 597.00 2.50870497e-01 -4.86001120e-02 2.55534689e-01 -0.19135555 0.87723034 597.25 2.56314612e-01 -9.43920768e-02 2.73142901e-01 -0.35285427 0.88684675 597.50 2.40167810e-01 -1.54585013e-01 2.85617057e-01 -0.57190124 0.93678043 597.75 2.28176191e-01 -1.62654418e-01 2.80215691e-01 -0.61929532 0.94824958 598.00 2.10168294e-01 -1.73229424e-01 2.72358486e-01 -0.68934854 0.95000140 598.25 2.02430401e-01 -1.70974527e-01 2.64972368e-01 -0.70135594 0.95972532 598.50 1.90710922e-01 -1.71229564e-01 2.56301033e-01 -0.73162530 0.94493842 598.75 1.95301429e-01 -1.86979401e-01 2.70377411e-01 -0.76363219 0.93930629 599.00 2.00327617e-01 -2.23600802e-01 3.00214045e-01 -0.84024197 0.95315934 599.25 1.94451506e-01 -2.42625823e-01 3.10931951e-01 -0.89517427 0.96022257 599.50 1.82895899e-01 -2.72210524e-01 3.27947373e-01 -0.97918535 0.93758726 599.75 1.59068518e-01 -2.89801604e-01 3.30586998e-01 -1.06880754 0.90992999 600.00 1.00470341e-01 -3.34598100e-01 3.49356806e-01 -1.27909028 0.91907127 600.25 5.36304354e-02 -3.32016715e-01 3.36320268e-01 -1.41065027 0.91114245 600.50 -3.39155178e-02 -3.20195936e-01 3.21987112e-01 -1.67632399 0.93778345 600.75 -5.71497653e-02 -2.86759944e-01 2.92399318e-01 -1.76751372 0.91484760 601.00 -7.69255336e-02 -2.23777220e-01 2.36630052e-01 -1.90190085 0.92179682 601.25 -7.71559080e-02 -1.89197505e-01 2.04325060e-01 -1.95801399 0.88011260 601.50 -5.56634699e-02 -1.60189375e-01 1.69584957e-01 -1.90522922 0.80807433 601.75 -3.24189807e-02 -1.60517946e-01 1.63758973e-01 -1.77008044 0.82034610 602.00 -2.30220275e-02 -1.68018846e-01 1.69588757e-01 -1.70696886 0.86259623 602.25 -4.42615101e-02 -1.81311641e-01 1.86635989e-01 -1.81023176 0.89227954 602.50 -7.56733789e-02 -1.74877352e-01 1.90548022e-01 -1.97918984 0.90740415 602.75 -8.47800371e-02 -1.41477930e-01 1.64935319e-01 -2.11066099 0.87727189 603.00 -8.38701055e-02 -1.22160237e-01 1.48180019e-01 -2.17244383 0.89588781 603.25 -8.96406074e-02 -1.37879296e-01 1.64457104e-01 -2.14726874 0.88955655 603.50 -9.36155879e-02 -1.56178458e-01 1.82086762e-01 -2.11078499 0.90892615 603.75 -1.14744494e-01 -1.46722374e-01 1.86262594e-01 -2.23449702 0.90791110 604.00 -1.48405178e-01 -1.34063806e-01 1.99993003e-01 -2.40692243 0.94801253 604.25 -1.70040947e-01 -9.58590474e-02 1.95199592e-01 -2.62826100 0.92042898 604.50 -1.99361727e-01 -6.12144898e-02 2.08548105e-01 -2.84367842 0.96135913 604.75 -2.03270328e-01 -2.75210417e-02 2.05124922e-01 -3.00701961 0.94728466 605.00 -2.08039475e-01 3.14810570e-03 2.08063292e-01 3.12646156 0.96697783 605.25 -2.11257395e-01 2.99148557e-02 2.13364912e-01 3.00092406 0.95907821 605.50 -2.12306114e-01 4.82933927e-02 2.17729506e-01 2.91792794 0.97316174 605.75 -2.10713683e-01 7.36365068e-02 2.23209748e-01 2.80539686 0.95798140 606.00 -2.12979650e-01 9.72265167e-02 2.34122462e-01 2.71334142 0.97279931 606.25 -2.12530114e-01 1.20639102e-01 2.44382574e-01 2.62531251 0.97175420 606.50 -2.14791085e-01 1.40904660e-01 2.56883891e-01 2.56100550 0.97688769 606.75 -2.18350108e-01 1.80332915e-01 2.83190271e-01 2.45126397 0.95996479 607.00 -2.26751490e-01 2.19831023e-01 3.15819438e-01 2.37168975 0.97145115 607.25 -2.15636179e-01 2.79005814e-01 3.52623321e-01 2.22877644 0.96331051 607.50 -2.04709503e-01 3.16483054e-01 3.76918432e-01 2.14493710 0.96877195 607.75 -1.58261131e-01 3.65703995e-01 3.98479607e-01 1.97921922 0.95382262 608.00 -1.12122933e-01 4.07917142e-01 4.23046034e-01 1.83903882 0.96049695 608.25 -4.71148060e-02 4.68484515e-01 4.70847689e-01 1.67102786 0.95786264 608.50 4.10084083e-03 4.71195700e-01 4.71213545e-01 1.56209349 0.95177867 608.75 1.20691207e-01 4.42557199e-01 4.58719132e-01 1.30455734 0.93322103 609.00 1.73602560e-01 4.01130000e-01 4.37084804e-01 1.16235126 0.94379471 609.25 2.35180387e-01 3.36571534e-01 4.10597385e-01 0.96090773 0.92236168 609.50 2.52840568e-01 2.86882899e-01 3.82400510e-01 0.84838837 0.89100411 609.75 2.53840123e-01 2.05318877e-01 3.26482235e-01 0.68011473 0.86468453 610.00 2.37970266e-01 1.58141937e-01 2.85724902e-01 0.58653228 0.77610734 610.25 1.70708709e-01 7.38340861e-02 1.85991763e-01 0.40821870 0.62371605 610.50 1.12156545e-01 4.79897615e-02 1.21992245e-01 0.40430915 0.39464593 610.75 1.37596037e-02 -1.04373113e-03 1.37991329e-02 -0.07570975 0.00963919 611.00 -3.49354310e-02 1.38948654e-02 3.75972290e-02 2.76304479 0.06857968 611.25 -1.40300409e-01 4.82718413e-02 1.48372421e-01 2.81021884 0.48500602 611.50 -2.09781156e-01 7.91732509e-02 2.24224301e-01 2.78071185 0.64654446 611.75 -2.99772748e-01 1.46440806e-01 3.33629451e-01 2.68718240 0.80528271 612.00 -3.38273248e-01 2.03882623e-01 3.94964447e-01 2.59917865 0.77580073 612.25 -3.93187357e-01 3.35386090e-01 5.16797956e-01 2.43536352 0.86116630 612.50 -3.81331980e-01 3.94705263e-01 5.48822671e-01 2.33896341 0.85841444 612.75 -3.97072145e-01 4.71343438e-01 6.16304247e-01 2.27087705 0.83806009 613.00 -3.84035546e-01 5.80225045e-01 6.95804860e-01 2.15547320 0.81889008 613.25 -3.78009253e-01 7.31062659e-01 8.23008874e-01 2.04800507 0.86642741 613.50 -3.39399517e-01 8.18459755e-01 8.86040859e-01 1.96389412 0.83939110 613.75 -3.30557561e-01 9.65556256e-01 1.02057199e+00 1.90063924 0.83296418 614.00 -1.43903535e-01 1.03660519e+00 1.04654601e+00 1.70873666 0.78122578 614.25 1.20248786e-01 1.12410337e+00 1.13051677e+00 1.46422852 0.86443326 614.50 2.22726723e-01 1.00182531e+00 1.02628512e+00 1.35203333 0.86052027 614.75 2.65950890e-01 8.62867844e-01 9.02923469e-01 1.27181778 0.89617705 615.00 2.52176040e-01 8.74372148e-01 9.10010663e-01 1.29000790 0.89863510 615.25 2.31743821e-01 8.47308061e-01 8.78428226e-01 1.30381963 0.91981491 615.50 1.98881303e-01 8.30571586e-01 8.54050896e-01 1.33577039 0.89713167 615.75 2.01632178e-01 8.62208833e-01 8.85471404e-01 1.34106936 0.93279279 616.00 1.81938185e-01 8.66752584e-01 8.85641883e-01 1.36389238 0.89941916 616.25 1.91206415e-01 9.31607804e-01 9.51027336e-01 1.36836409 0.91442400 616.50 2.86932662e-01 9.38213131e-01 9.81108675e-01 1.27400056 0.91380442 616.75 3.18955612e-01 9.25932979e-01 9.79328629e-01 1.23905698 0.90690846 617.00 3.54561579e-01 8.91996844e-01 9.59881390e-01 1.19245392 0.89782697 617.25 4.14153011e-01 9.21661727e-01 1.01043706e+00 1.14847918 0.91336338 617.50 3.93853288e-01 8.95695720e-01 9.78463712e-01 1.15652596 0.92485099 617.75 3.54369718e-01 8.94187757e-01 9.61846996e-01 1.19348066 0.91505004 618.00 4.21718783e-01 9.19419905e-01 1.01152345e+00 1.14074826 0.86180988 618.25 5.30337460e-01 8.90053944e-01 1.03607618e+00 1.03343487 0.87785001 618.50 5.94358866e-01 8.10363912e-01 1.00496375e+00 0.93797367 0.88707167 618.75 6.43635715e-01 7.86695667e-01 1.01644331e+00 0.88508538 0.91115354 619.00 6.07712080e-01 8.19879481e-01 1.02054708e+00 0.93293734 0.88515393 619.25 5.91174467e-01 7.35397886e-01 9.43555669e-01 0.89369168 0.84990363 619.50 6.16420097e-01 6.21477377e-01 8.75333004e-01 0.78948352 0.86478995 619.75 6.40263298e-01 5.60525769e-01 8.50956067e-01 0.71909123 0.87851527 620.00 6.55418537e-01 4.42032441e-01 7.90547998e-01 0.59335642 0.87608058 620.25 5.90776403e-01 3.79896220e-01 7.02380165e-01 0.57147088 0.84332839 620.50 4.77719681e-01 2.88811801e-01 5.58236823e-01 0.54376814 0.85359818 620.75 4.26361838e-01 2.57577480e-01 4.98127068e-01 0.54344988 0.84193359 621.00 2.88754153e-01 2.33570234e-01 3.71394689e-01 0.68013798 0.78020565 621.25 2.10395460e-01 2.80514232e-01 3.50648662e-01 0.92727289 0.71282412 621.50 7.72820229e-02 4.15567903e-01 4.22692788e-01 1.38692947 0.76115694 621.75 5.17470381e-02 4.69967811e-01 4.72808100e-01 1.46113047 0.74062892 622.00 7.56491852e-02 7.03514841e-01 7.07570443e-01 1.46367759 0.80130887 622.25 1.53183993e-01 8.15249463e-01 8.29516137e-01 1.38506363 0.78176295 622.50 3.41230294e-01 9.94057124e-01 1.05099366e+00 1.24012931 0.76173638 622.75 4.84071708e-01 1.00687910e+00 1.11719781e+00 1.12265521 0.75992732 623.00 8.35392135e-01 9.32939073e-01 1.25230002e+00 0.84050558 0.69037370 623.25 1.13657858e+00 8.61756175e-01 1.42633607e+00 0.64872977 0.56715064 623.50 1.51364307e+00 4.95518091e-01 1.59268751e+00 0.31637205 0.47799173 623.75 1.39095222e+00 -2.73776106e-01 1.41763939e+00 -0.19434216 0.37855573 624.00 1.11505434e+00 -1.47992758e+00 1.85297918e+00 -0.92508962 0.55803161 624.25 3.90873307e-01 -1.60986914e+00 1.65664136e+00 -1.33260724 0.59833029 624.50 -2.56977287e-01 -1.87867440e+00 1.89616846e+00 -1.70673916 0.77495487 624.75 -5.89005127e-01 -1.58232786e+00 1.68839820e+00 -1.92714475 0.79148581 625.00 -8.64168511e-01 -1.26250320e+00 1.52993514e+00 -2.17103563 0.86776092 625.25 -9.84836720e-01 -8.49239381e-01 1.30042720e+00 -2.42999246 0.85169835 625.50 -9.10535534e-01 -6.27614596e-01 1.10588202e+00 -2.53809712 0.90868929 625.75 -8.79547455e-01 -4.83646545e-01 1.00375181e+00 -2.63884071 0.92480715 626.00 -8.33173122e-01 -3.81799555e-01 9.16486962e-01 -2.71190126 0.94451327 626.25 -7.65893271e-01 -3.22926856e-01 8.31188460e-01 -2.74257625 0.95982013 626.50 -7.48294901e-01 -2.94733895e-01 8.04247056e-01 -2.76637845 0.96534793 626.75 -7.25414776e-01 -2.77510887e-01 7.76684549e-01 -2.77621512 0.95091322 627.00 -7.20268990e-01 -2.47406174e-01 7.61575494e-01 -2.81072790 0.96179501 627.25 -7.45892656e-01 -1.86999654e-01 7.68976414e-01 -2.89594977 0.95813164 627.50 -7.35282938e-01 -1.65701157e-01 7.53722676e-01 -2.91993844 0.94937730 627.75 -7.35333116e-01 -9.95484250e-02 7.42040888e-01 -3.00703204 0.90778332 628.00 -7.52584185e-01 -3.24756309e-02 7.53284556e-01 -3.09846725 0.91715095 628.25 -7.01822158e-01 1.45195076e-01 7.16683997e-01 2.93758767 0.90900366 628.50 -6.36304469e-01 1.86715063e-01 6.63133389e-01 2.85616809 0.92879478 628.75 -5.49209972e-01 1.57683163e-01 5.71397912e-01 2.86200395 0.89680937 629.00 -5.08975256e-01 1.77522065e-01 5.39045355e-01 2.80600217 0.87246906 629.25 -4.65225568e-01 1.79868925e-01 4.98786186e-01 2.77266732 0.83848326 629.50 -4.18282162e-01 1.83874842e-01 4.56913476e-01 2.72742495 0.84697623 629.75 -3.88082207e-01 2.00254349e-01 4.36703107e-01 2.66521913 0.87439217 630.00 -3.50844453e-01 1.93737905e-01 4.00781993e-01 2.63705846 0.86895773 630.25 -3.27003642e-01 1.58265645e-01 3.63289687e-01 2.69083698 0.92442183 630.50 -3.00231634e-01 1.34481531e-01 3.28974644e-01 2.72046487 0.92146381 630.75 -2.68470237e-01 9.68505729e-02 2.85405504e-01 2.79537349 0.91479749 631.00 -2.60458182e-01 8.35906797e-02 2.73543171e-01 2.83103993 0.89864843 631.25 -2.73620467e-01 6.92373522e-02 2.82244523e-01 2.89375339 0.90583275 631.50 -2.78139891e-01 7.20477453e-02 2.87319816e-01 2.88812945 0.92026388 631.75 -2.67639319e-01 7.27045591e-02 2.77338706e-01 2.87634239 0.93240320 632.00 -2.70084334e-01 7.19481949e-02 2.79503292e-01 2.88124709 0.94305594 632.25 -2.90311813e-01 7.79336404e-02 3.00590421e-01 2.87932788 0.96558123 632.50 -2.80268644e-01 8.77325934e-02 2.93679282e-01 2.83822469 0.96445599 632.75 -2.70700555e-01 1.01023644e-01 2.88936961e-01 2.78440684 0.97439652 633.00 -2.52594364e-01 1.13837820e-01 2.77061297e-01 2.71817801 0.96431460 633.25 -2.23390646e-01 1.27255060e-01 2.57093817e-01 2.62378638 0.96402348 633.50 -2.05956659e-01 1.18268378e-01 2.37498536e-01 2.62033036 0.95973872 633.75 -1.79406344e-01 1.13587726e-01 2.12341253e-01 2.57716765 0.96078786 634.00 -1.56238082e-01 1.01667591e-01 1.86404500e-01 2.56470989 0.93834079 634.25 -1.35331856e-01 7.86676466e-02 1.56535331e-01 2.61504085 0.93975903 634.50 -1.22793460e-01 5.93572417e-02 1.36387374e-01 2.69132039 0.93687993 634.75 -1.10402716e-01 3.88186601e-02 1.17028407e-01 2.80348457 0.91877945 635.00 -1.02513404e-01 9.71268779e-03 1.02972493e-01 3.04712910 0.88776849 635.25 -1.00372125e-01 -1.49869170e-02 1.01484832e-01 -2.99337413 0.90117571 635.50 -1.07803453e-01 -4.45533813e-02 1.16647281e-01 -2.74968775 0.87059551 635.75 -1.20339599e-01 -7.55553696e-02 1.42092339e-01 -2.58094562 0.93140424 636.00 -1.41664799e-01 -8.86962790e-02 1.67140495e-01 -2.58220298 0.91375605 636.25 -1.69770028e-01 -1.01452883e-01 1.97773987e-01 -2.60294704 0.95348154 636.50 -1.87302384e-01 -9.77078746e-02 2.11255798e-01 -2.66076878 0.95191550 636.75 -2.01020253e-01 -9.32500236e-02 2.21595823e-01 -2.70725319 0.95167448 637.00 -2.16543875e-01 -7.97872066e-02 2.30775319e-01 -2.78857021 0.95900669 637.25 -2.16714227e-01 -7.07996459e-02 2.27986066e-01 -2.82582765 0.95798936 637.50 -2.01528285e-01 -5.57624704e-02 2.09100700e-01 -2.87164853 0.95352452 637.75 -2.02113353e-01 -5.43866968e-02 2.09302939e-01 -2.87872911 0.96087537 638.00 -1.90550531e-01 -5.06105652e-02 1.97157131e-01 -2.88198469 0.95881492 638.25 -1.85640148e-01 -5.59401941e-02 1.93885456e-01 -2.84890996 0.95809347 638.50 -1.72161745e-01 -6.59819667e-02 1.84372684e-01 -2.77560384 0.93898319 638.75 -1.71145087e-01 -7.32940923e-02 1.86179120e-01 -2.73696648 0.94205484 639.00 -1.71936672e-01 -8.94630194e-02 1.93819119e-01 -2.66181725 0.94321401 639.25 -1.67894201e-01 -1.00721745e-01 1.95789000e-01 -2.60123787 0.94828534 639.50 -1.79504393e-01 -1.23667937e-01 2.17980700e-01 -2.53832746 0.94770969 639.75 -1.88628796e-01 -1.34003409e-01 2.31382230e-01 -2.52391554 0.94910380 640.00 -1.98522742e-01 -1.26866024e-01 2.35597681e-01 -2.57295347 0.94223742 640.25 -2.00328266e-01 -1.30318336e-01 2.38985947e-01 -2.56484919 0.94676782 640.50 -2.23214357e-01 -1.28216488e-01 2.57418176e-01 -2.62020213 0.95342815 640.75 -2.19544080e-01 -1.21652995e-01 2.50996124e-01 -2.63559448 0.95365220 641.00 -2.10461238e-01 -1.21172479e-01 2.42851194e-01 -2.61919698 0.94265769 641.25 -2.01549645e-01 -1.16985526e-01 2.33040496e-01 -2.61568691 0.90565988 641.50 -1.70320681e-01 -1.19453477e-01 2.08034294e-01 -2.52996489 0.87470440 641.75 -1.66320377e-01 -1.22722488e-01 2.06696098e-01 -2.50590133 0.81707529 642.00 -1.36855344e-01 -1.71005962e-01 2.19026081e-01 -2.24571758 0.75244024 642.25 -1.15086385e-01 -2.15563664e-01 2.44361554e-01 -2.06118369 0.72909960 642.50 -7.12772805e-02 -2.78620555e-01 2.87593228e-01 -1.82124701 0.74616797 642.75 -3.78911569e-02 -3.31051027e-01 3.33212429e-01 -1.68475756 0.69561281 643.00 3.00335546e-02 -3.94247102e-01 3.95389418e-01 -1.49476366 0.58008537 643.25 -6.66819166e-02 -4.02166500e-01 4.07657174e-01 -1.73510820 0.39742295 643.50 -3.01410564e-01 -5.58786032e-01 6.34893816e-01 -2.06546685 0.28975995 643.75 -6.14479208e-01 -4.47360338e-01 7.60076291e-01 -2.51230014 0.34958272 644.00 -7.37103616e-01 -2.72995236e-01 7.86033167e-01 -2.78689428 0.36022201 644.25 -8.77295629e-01 3.30450622e-02 8.77917762e-01 3.10394349 0.51329460 644.50 -1.13793428e+00 2.10145827e-01 1.15717574e+00 2.95897701 0.72820969 644.75 -8.63144591e-01 4.94236304e-01 9.94629634e-01 2.62156416 0.68181385 645.00 -8.66303716e-01 4.97726640e-01 9.99106569e-01 2.62010371 0.85287075 645.25 -9.04072290e-01 5.27873457e-01 1.04689880e+00 2.61310735 0.87069829 645.50 -8.77404119e-01 6.53431383e-01 1.09398837e+00 2.50147126 0.88212841 645.75 -8.13018871e-01 5.70875175e-01 9.93427476e-01 2.52941368 0.86571676 646.00 -8.10347134e-01 5.96610984e-01 1.00628383e+00 2.50695546 0.91793160 646.25 -7.78239661e-01 6.88069171e-01 1.03879553e+00 2.41761203 0.92394841 646.50 -7.71703100e-01 7.84238343e-01 1.10025245e+00 2.34813829 0.93331047 646.75 -7.18608970e-01 7.87659029e-01 1.06621086e+00 2.31038475 0.93069086 647.00 -6.58058316e-01 8.13606879e-01 1.04642100e+00 2.25088985 0.94041633 647.25 -6.15186963e-01 8.81651264e-01 1.07506463e+00 2.18002191 0.95209920 647.50 -6.02364516e-01 9.43182625e-01 1.11912308e+00 2.13915191 0.96467939 647.75 -5.26633292e-01 1.03119178e+00 1.15788562e+00 2.04297006 0.94810247 648.00 -4.59794579e-01 1.10597790e+00 1.19774713e+00 1.96479400 0.95756153 648.25 -3.11918288e-01 1.19014636e+00 1.23034198e+00 1.82711541 0.96455863 648.50 -2.10188600e-01 1.23480167e+00 1.25256313e+00 1.73940082 0.96468359 648.75 -4.53804397e-02 1.24437873e+00 1.24520593e+00 1.60724852 0.96360180 649.00 5.36842165e-02 1.22996429e+00 1.23113531e+00 1.52717704 0.97446016 649.25 1.94777724e-01 1.14657414e+00 1.16300069e+00 1.40252474 0.97918037 649.50 2.48296133e-01 1.10861999e+00 1.13608505e+00 1.35046375 0.98466150 649.75 3.29349140e-01 1.07986908e+00 1.12897656e+00 1.27476797 0.98749200 650.00 3.76387362e-01 1.04598885e+00 1.11164748e+00 1.22538347 0.98538719 650.25 4.28654212e-01 9.64422145e-01 1.05539306e+00 1.15255282 0.98364400 650.50 4.99519995e-01 9.50303091e-01 1.07359033e+00 1.08684553 0.98276096 650.75 6.05191223e-01 8.71728760e-01 1.06121037e+00 0.96394486 0.98816813 651.00 6.35774771e-01 8.22123158e-01 1.03927669e+00 0.91252872 0.99051415 651.25 6.88454334e-01 7.56957169e-01 1.02320747e+00 0.83275604 0.98853753 651.50 7.10044137e-01 7.26792224e-01 1.01606575e+00 0.79705386 0.98538650 651.75 7.64220978e-01 6.51447151e-01 1.00419973e+00 0.70590483 0.97604996 652.00 7.90921134e-01 5.66087500e-01 9.72631122e-01 0.62120645 0.97402077 652.25 7.79088117e-01 4.82111138e-01 9.16192908e-01 0.55413905 0.97438365 652.50 7.88342132e-01 4.13056149e-01 8.89999270e-01 0.48262779 0.96783211 652.75 7.47279951e-01 3.35720951e-01 8.19228834e-01 0.42223610 0.97486117 653.00 7.27206748e-01 3.03230401e-01 7.87894872e-01 0.39505776 0.97055047 653.25 6.92732328e-01 2.59760286e-01 7.39833416e-01 0.35875253 0.97297201 653.50 6.80892301e-01 2.35913530e-01 7.20603580e-01 0.33353286 0.97150260 653.75 6.70182540e-01 1.79849218e-01 6.93895077e-01 0.26218129 0.97376480 654.00 6.34170458e-01 1.54048021e-01 6.52612414e-01 0.23829716 0.96888172 654.25 6.16813345e-01 9.96599535e-02 6.24812619e-01 0.16018794 0.95741296 654.50 5.40317303e-01 9.55837921e-02 5.48706706e-01 0.17509159 0.90907972 654.75 4.61193098e-01 1.30875851e-01 4.79403339e-01 0.27650738 0.91916638 655.00 3.98241285e-01 2.21861139e-01 4.55871129e-01 0.50827968 0.86870659 655.25 3.55998475e-01 3.09640547e-01 4.71817955e-01 0.71586619 0.90181717 655.50 3.56179058e-01 4.29641226e-01 5.58081629e-01 0.87861194 0.90263884 655.75 4.57364895e-01 5.37166559e-01 7.05500219e-01 0.86546708 0.96081179 656.00 5.47780033e-01 5.61871254e-01 7.84705212e-01 0.79809626 0.96664987 656.25 6.10445518e-01 6.25810914e-01 8.74232824e-01 0.79782650 0.96986597 656.50 6.84520431e-01 6.54529373e-01 9.47088655e-01 0.76300464 0.96270371 656.75 7.54885004e-01 6.39056217e-01 9.89062292e-01 0.70249417 0.96343675 657.00 8.10609410e-01 6.20845992e-01 1.02104719e+00 0.65359988 0.97411363 657.25 8.25552763e-01 6.23321221e-01 1.03444029e+00 0.64671572 0.98312693 657.50 7.87444380e-01 6.11719379e-01 9.97130508e-01 0.66045946 0.97363736 657.75 7.56938488e-01 6.18321758e-01 9.77383073e-01 0.68494434 0.97838384 658.00 6.73589813e-01 6.92852728e-01 9.66316790e-01 0.79949436 0.96892523 658.25 6.16820204e-01 7.38988363e-01 9.62585562e-01 0.87526271 0.95880808 658.50 4.67121940e-01 8.53793667e-01 9.73224811e-01 1.07017203 0.94181976 658.75 3.82177476e-01 9.31661475e-01 1.00700185e+00 1.18151876 0.95398962 659.00 2.24674987e-01 1.04481951e+00 1.06870326e+00 1.35898468 0.91440184 659.25 9.49902825e-02 1.09944962e+00 1.10354548e+00 1.48461231 0.92309228 659.50 -1.45298107e-02 1.18231260e+00 1.18240188e+00 1.58308502 0.91957069 659.75 -9.02788310e-02 1.24578869e+00 1.24905554e+00 1.64313708 0.90926372 660.00 -2.56991293e-01 1.11804845e+00 1.14720393e+00 1.79672892 0.84140581 660.25 -3.75869698e-01 1.11342755e+00 1.17515911e+00 1.89636305 0.86119994 660.50 -6.02915948e-01 1.02305579e+00 1.18749770e+00 2.10333219 0.88129083 660.75 -7.26913141e-01 1.05393960e+00 1.28030910e+00 2.17458311 0.90171819 661.00 -9.08229308e-01 1.24908839e+00 1.54437764e+00 2.19948861 0.88666542 661.25 -8.39224485e-01 1.41920227e+00 1.64876706e+00 2.10482041 0.88808244 661.50 -4.92795925e-01 1.57724191e+00 1.65243453e+00 1.87362795 0.93590698 661.75 -3.78585931e-01 1.37797230e+00 1.42903287e+00 1.83892203 0.93186169 662.00 -2.27946567e-01 1.12017413e+00 1.14313154e+00 1.77154739 0.95358713 662.25 -2.14117974e-01 9.94460441e-01 1.01725025e+00 1.78286944 0.94560438 662.50 -2.62483223e-01 7.89744432e-01 8.32222152e-01 1.89167492 0.96536804 662.75 -2.66783531e-01 7.35601572e-01 7.82485223e-01 1.91871706 0.96708446 663.00 -2.91037242e-01 6.58301557e-01 7.19766363e-01 1.98706392 0.95097272 663.25 -2.95310541e-01 6.36561117e-01 7.01725282e-01 2.00516190 0.95319732 663.50 -3.26965343e-01 5.69707285e-01 6.56865836e-01 2.09181718 0.95340205 663.75 -3.22643643e-01 5.55734033e-01 6.42603483e-01 2.09680806 0.95121356 664.00 -3.28901431e-01 5.51266966e-01 6.41927893e-01 2.10873289 0.96197153 664.25 -2.93477954e-01 5.79653920e-01 6.49713765e-01 2.03947009 0.95336330 664.50 -1.92140818e-01 5.92070409e-01 6.22467239e-01 1.88459727 0.94636144 664.75 -1.45538678e-01 5.56779841e-01 5.75487009e-01 1.82646929 0.92684783 665.00 -7.53172430e-02 5.56325642e-01 5.61400844e-01 1.70536155 0.91935226 665.25 -2.93159272e-02 4.96802758e-01 4.97666961e-01 1.62973717 0.85810064 665.50 7.55082016e-02 3.75680259e-01 3.83193353e-01 1.37244845 0.80039220 665.75 1.07908221e-01 3.05296775e-01 3.23805968e-01 1.23104819 0.80268754 666.00 1.10153067e-01 2.41888081e-01 2.65788529e-01 1.14347031 0.82850545 666.25 5.02517016e-02 1.45073598e-01 1.53530395e-01 1.23734326 0.55852692 666.50 -6.88650508e-03 5.05332235e-02 5.10003003e-02 1.70623877 0.18338533 666.75 -4.19688416e-02 3.97473438e-02 5.78034169e-02 2.38337333 0.20871870 667.00 -9.71218647e-02 2.45483115e-02 1.00176226e-01 2.89402008 0.50052470 667.25 -1.25030862e-01 2.17098204e-02 1.26901666e-01 2.96967106 0.64303514 667.50 -1.42083692e-01 2.63953646e-02 1.44514673e-01 2.95791322 0.75364936 667.75 -1.59998277e-01 4.01660108e-02 1.64962896e-01 2.89563515 0.83193322 668.00 -1.69987123e-01 3.61818444e-02 1.73795132e-01 2.93187193 0.90087515 668.25 -1.81098059e-01 2.08140921e-02 1.82290245e-01 3.02716203 0.85802647 668.50 -1.99321565e-01 2.10513273e-02 2.00430149e-01 3.03636784 0.87750206 668.75 -2.36622756e-01 1.87353005e-02 2.37363308e-01 3.06257956 0.91771329 669.00 -2.51825533e-01 1.92253448e-02 2.52558336e-01 3.06539655 0.92589197 669.25 -3.04308523e-01 5.72465581e-02 3.09646324e-01 2.95564570 0.90782983 669.50 -3.45183472e-01 7.64854145e-02 3.53555721e-01 2.92353673 0.93848172 669.75 -3.43896624e-01 1.36220746e-01 3.69893200e-01 2.76444458 0.90321678 670.00 -3.39923606e-01 2.07309109e-01 3.98152138e-01 2.59394761 0.90002656 670.25 -2.40189703e-01 2.78869121e-01 3.68047660e-01 2.28181360 0.82823418 670.50 -1.30211166e-01 2.94232937e-01 3.21757625e-01 1.98743298 0.77809792 670.75 -2.42211074e-02 2.53888854e-01 2.55041589e-01 1.66590891 0.67005286 671.00 1.66169498e-02 2.09577260e-01 2.10234989e-01 1.49167391 0.55744099 671.25 1.93882176e-02 7.79021270e-02 8.02785424e-02 1.32687283 0.17859249 671.50 -3.90663086e-03 5.54502831e-02 5.55877294e-02 1.64113296 0.12115507 671.75 -8.52080671e-02 2.86682824e-02 8.99015301e-02 2.81703943 0.19271858 672.00 -1.12180658e-01 -1.21709242e-02 1.12838963e-01 -3.03352140 0.24403839 672.25 -1.79896148e-01 -2.82764969e-02 1.82104872e-01 -2.98568592 0.55499143 672.50 -2.25024526e-01 -3.34232338e-02 2.27493186e-01 -2.99413919 0.68900002 672.75 -2.61365251e-01 -2.17565354e-02 2.62269215e-01 -3.05854224 0.76444517 673.00 -2.91860672e-01 1.41112652e-02 2.92201608e-01 3.09328095 0.78504292 673.25 -3.15108446e-01 4.75632951e-02 3.18677894e-01 2.99178095 0.84087439 673.50 -3.18462143e-01 8.18283221e-02 3.28806951e-01 2.89008513 0.86759803 673.75 -3.07738016e-01 1.23440695e-01 3.31572453e-01 2.76011883 0.94040403 674.00 -2.85473173e-01 1.55786307e-01 3.25214246e-01 2.64204707 0.93085115 674.25 -2.47514996e-01 2.26369591e-01 3.35420431e-01 2.40078633 0.95105758 674.50 -2.08192180e-01 2.38689647e-01 3.16728166e-01 2.28805510 0.96477418 674.75 -1.80469890e-01 2.45627395e-01 3.04798620e-01 2.20445299 0.98070665 675.00 -1.53614719e-01 2.29202060e-01 2.75918586e-01 2.16125163 0.96792302 675.25 -1.19757576e-01 2.11018961e-01 2.42633220e-01 2.08699136 0.98444544 675.50 -1.13916791e-01 2.00619486e-01 2.30705902e-01 2.08722181 0.98073821 675.75 -1.10121441e-01 1.88507184e-01 2.18315574e-01 2.09949954 0.98113822 676.00 -1.01242124e-01 1.82768012e-01 2.08935670e-01 2.07665783 0.97009460 676.25 -8.98334986e-02 1.77983872e-01 1.99369798e-01 2.03821942 0.98560221 676.50 -8.31586040e-02 1.79218635e-01 1.97571943e-01 2.00523678 0.98356502 676.75 -7.99753811e-02 1.78188993e-01 1.95313540e-01 1.99267132 0.98683815 677.00 -7.65332828e-02 1.78368841e-01 1.94094788e-01 1.97611191 0.98297443 677.25 -7.15811138e-02 1.80179146e-01 1.93877230e-01 1.94895349 0.98401983 677.50 -5.79596544e-02 1.87418839e-01 1.96176305e-01 1.87071945 0.96708924 677.75 -3.03308456e-02 1.88154382e-01 1.90583398e-01 1.73062328 0.96789649 678.00 2.14769596e-03 1.70551101e-01 1.70564623e-01 1.55820431 0.95740738 678.25 1.58681324e-02 1.57545490e-01 1.58342601e-01 1.47041391 0.96268103 678.50 2.35324640e-02 1.33037489e-01 1.35102740e-01 1.39572133 0.89662794 678.75 2.66597930e-02 1.08160223e-01 1.11397389e-01 1.32912932 0.87855613 679.00 2.49970797e-02 8.71956901e-02 9.07080061e-02 1.29160598 0.72362539 679.25 1.80025138e-02 7.04697460e-02 7.27329059e-02 1.32068132 0.72351768 679.50 5.44817235e-03 7.45813230e-02 7.47800529e-02 1.49787576 0.74456272 679.75 5.07574382e-04 7.86769885e-02 7.86786258e-02 1.56434505 0.80231082 680.00 -2.89015076e-04 8.22321536e-02 8.22326615e-02 1.57431094 0.82495315 680.25 3.54533621e-03 8.53797655e-02 8.54533427e-02 1.52929585 0.83174800 680.50 8.50539339e-03 8.40484667e-02 8.44777277e-02 1.46994337 0.78588637 680.75 1.63380440e-02 7.99751272e-02 8.16269114e-02 1.36928009 0.79310126 681.00 2.41230976e-02 8.63076390e-02 8.96154696e-02 1.29825013 0.78234597 681.25 3.06697560e-02 8.95768482e-02 9.46818127e-02 1.24092164 0.77232276 681.50 7.02270772e-02 1.14509832e-01 1.34329237e-01 1.02066621 0.73905490 681.75 9.22843730e-02 1.37950101e-01 1.65971793e-01 0.98120133 0.74857855 682.00 1.67930696e-01 1.77136310e-01 2.44086031e-01 0.81206960 0.68424700 682.25 2.67094924e-01 1.51027449e-01 3.06837072e-01 0.51462368 0.66024339 682.50 3.89996486e-01 -8.29776963e-03 3.90084750e-01 -0.02127331 0.62906069 682.75 3.77996239e-01 -1.70700942e-01 4.14752900e-01 -0.42417895 0.55712539 683.00 2.33747732e-01 -4.45559747e-01 5.03151558e-01 -1.08765047 0.61288082 683.25 1.19508198e-01 -4.90732418e-01 5.05074763e-01 -1.33191603 0.60520099 683.50 -1.77661883e-01 -5.31355705e-01 5.60270140e-01 -1.89346685 0.69448995 683.75 -2.69805138e-01 -5.26887741e-01 5.91950592e-01 -2.04405585 0.75240248 684.00 -3.20696326e-01 -4.50389957e-01 5.52898948e-01 -2.18955818 0.73844536 684.25 -3.25068232e-01 -3.43781548e-01 4.73133288e-01 -2.32822343 0.69784704 684.50 -3.61343155e-01 -2.77769502e-01 4.55768332e-01 -2.48622184 0.75906306 684.75 -3.71049551e-01 -2.40257028e-01 4.42042090e-01 -2.56697227 0.77027856 685.00 -4.00630996e-01 -1.98840021e-01 4.47261164e-01 -2.68089569 0.80461407 685.25 -3.90945925e-01 -1.81768923e-01 4.31136472e-01 -2.70637901 0.76455677 685.50 -4.71269029e-01 -1.98588518e-01 5.11401894e-01 -2.74278285 0.75924196 685.75 -4.85072142e-01 -1.79832776e-01 5.17334331e-01 -2.78656720 0.70633895 686.00 -5.58609650e-01 -1.38887224e-01 5.75616541e-01 -2.89790364 0.70234422 686.25 -5.31948429e-01 -9.77215601e-02 5.40849919e-01 -2.95991337 0.57066370 686.50 -5.31816807e-01 -1.08840993e-01 5.42840196e-01 -2.93972151 0.40998113 686.75 -4.87331459e-01 5.68944841e-02 4.90641349e-01 3.02537178 0.35845448 687.00 -4.50990201e-01 1.50149153e-01 4.75328233e-01 2.82020318 0.31141268 687.25 -3.47491429e-01 1.31213475e-01 3.71439455e-01 2.78054269 0.24343382 687.50 -2.19937641e-01 1.36529282e-01 2.58868327e-01 2.58604554 0.14210385 687.75 -3.28701818e-02 1.25745853e-01 1.29971029e-01 1.82647690 0.04996322 688.00 3.68941449e-02 7.46413521e-02 8.32616921e-02 1.11173069 0.03450202 688.25 1.31563353e-01 1.80934101e-01 2.23709778e-01 0.94209072 0.37899526 688.50 1.46229101e-01 2.19141475e-01 2.63450064e-01 0.98236804 0.65422806 688.75 9.84468310e-02 2.16895254e-01 2.38191792e-01 1.14471125 0.69625548 689.00 9.29313283e-02 2.14722951e-01 2.33970463e-01 1.16234060 0.76880353 689.25 6.61726258e-02 2.12534209e-01 2.22597408e-01 1.26895906 0.83414539 689.50 3.98189981e-02 2.17636278e-01 2.21248960e-01 1.38983659 0.87305127 689.75 1.30759308e-02 2.02191676e-01 2.02614051e-01 1.50621529 0.88251751 690.00 1.13670817e-02 2.13763920e-01 2.14065934e-01 1.51767050 0.90942145 690.25 -5.62495620e-03 2.13353759e-01 2.13427896e-01 1.59715468 0.94076991 690.50 -1.19238143e-02 2.15915719e-01 2.16244711e-01 1.62596468 0.95649089 690.75 -2.37117109e-03 2.37903698e-01 2.37915515e-01 1.58076293 0.95975625 691.00 1.93768266e-03 2.43824933e-01 2.43832633e-01 1.56284947 0.96832805 691.25 1.63663766e-02 2.48071885e-01 2.48611179e-01 1.50491747 0.96565996 691.50 2.46545959e-02 2.43172035e-01 2.44418673e-01 1.46975414 0.95470805 691.75 5.56663783e-02 2.40181909e-01 2.46548363e-01 1.34304982 0.96448180 692.00 6.87709031e-02 2.33910061e-01 2.43810077e-01 1.28484788 0.97045963 692.25 8.00987209e-02 2.01330427e-01 2.16678901e-01 1.19214730 0.96936621 692.50 7.87958491e-02 1.89431758e-01 2.05166218e-01 1.17660832 0.96766325 692.75 8.91821685e-02 1.74650649e-01 1.96102801e-01 1.09867953 0.96304456 693.00 8.68126073e-02 1.60370629e-01 1.82359994e-01 1.07463788 0.94489699 693.25 8.32213053e-02 1.39270150e-01 1.62240440e-01 1.03217799 0.94765831 693.50 7.98804571e-02 1.32276653e-01 1.54525080e-01 1.02752194 0.94722895 693.75 7.08870282e-02 1.21843442e-01 1.40963807e-01 1.04387580 0.94681750 694.00 6.57192172e-02 1.16871447e-01 1.34081880e-01 1.05854319 0.94141108 694.25 5.68692291e-02 1.21111053e-01 1.33798342e-01 1.13179370 0.96757837 694.50 5.40333734e-02 1.23400474e-01 1.34711849e-01 1.15807532 0.96803035 694.75 5.65661274e-02 1.13934857e-01 1.27204081e-01 1.10997044 0.97014086 695.00 5.76693466e-02 1.08057567e-01 1.22483433e-01 1.08056061 0.96867871 695.25 5.78803823e-02 9.52691333e-02 1.11473523e-01 1.02484675 0.96639802 695.50 5.64305740e-02 8.82368478e-02 1.04738489e-01 1.00181291 0.96822086 695.75 5.53128027e-02 8.04660547e-02 9.76436998e-02 0.96857320 0.96814191 696.00 5.31561881e-02 7.91253561e-02 9.53226222e-02 0.97925026 0.97510692 696.25 5.09388626e-02 7.35301499e-02 8.94508282e-02 0.96494490 0.97576226 696.50 4.79747378e-02 6.97645254e-02 8.46679660e-02 0.96839582 0.95607226 696.75 4.23183876e-02 6.28259935e-02 7.57492666e-02 0.97802223 0.93276042 697.00 3.71982969e-02 5.88869977e-02 6.96519331e-02 1.00740106 0.93052175 697.25 3.50434243e-02 5.42460676e-02 6.45807822e-02 0.99723216 0.94568084 697.50 3.18045482e-02 5.08330595e-02 5.99627319e-02 1.01171779 0.88508884 697.75 2.48629121e-02 4.14308199e-02 4.83184979e-02 1.03029838 0.82355905 698.00 1.16286595e-02 4.08202042e-02 4.24442551e-02 1.29327270 0.72409812 698.25 -7.26799370e-04 4.23795943e-02 4.23858261e-02 1.58794439 0.73952170 698.50 -1.00352076e-02 5.00956635e-02 5.10909081e-02 1.76850041 0.86491016 698.75 -1.53314167e-02 5.37611666e-02 5.59045202e-02 1.84859864 0.91833314 699.00 -1.86552889e-02 6.41548423e-02 6.68121515e-02 1.85377803 0.92137029 699.25 -1.56576531e-02 7.04243823e-02 7.21439930e-02 1.78957068 0.96109726 699.50 -1.00834577e-02 7.25762549e-02 7.32733846e-02 1.70884861 0.96299688 699.75 -4.00859469e-03 7.48566245e-02 7.49638784e-02 1.62429553 0.96990363 700.00 1.65223448e-03 7.70978976e-02 7.71155996e-02 1.54936926 0.96320471 700.25 4.00275049e-03 7.61398845e-02 7.62450262e-02 1.51827367 0.96610591 700.50 9.14890705e-03 7.55550487e-02 7.61069503e-02 1.45029371 0.96513701 700.75 1.18975826e-02 7.14536767e-02 7.24374239e-02 1.40580239 0.97349663 701.00 1.66912314e-02 6.77878135e-02 6.98124979e-02 1.32937129 0.97177475 701.25 2.01543794e-02 6.54122738e-02 6.84468010e-02 1.27191303 0.96593108 701.50 1.29975522e-02 5.53276995e-02 5.68338868e-02 1.34006071 0.92521187 701.75 8.78089196e-03 5.17210964e-02 5.24611845e-02 1.40262593 0.91688688 702.00 2.63420352e-03 5.06861167e-02 5.07545216e-02 1.51887213 0.90957761 702.25 -1.25993031e-03 5.23814122e-02 5.23965625e-02 1.59484469 0.88109072 702.50 -6.41062643e-03 6.05479792e-02 6.08864018e-02 1.67628015 0.92160028 702.75 -5.97851790e-03 6.19632292e-02 6.22509795e-02 1.66698352 0.94283516 703.00 1.32653750e-03 6.79105080e-02 6.79234628e-02 1.55126520 0.94824172 703.25 6.01303803e-03 7.35427937e-02 7.37882046e-02 1.48921536 0.94822129 703.50 1.30675949e-02 7.38703442e-02 7.50172632e-02 1.39570862 0.95205596 703.75 1.90762700e-02 7.61199351e-02 7.84738721e-02 1.32524544 0.94808969 704.00 3.17294981e-02 7.47198617e-02 8.11776988e-02 1.16922547 0.92210435 704.25 3.77109642e-02 6.84097700e-02 7.81153855e-02 1.06699305 0.88597780 704.50 4.29041229e-02 5.63067671e-02 7.07899413e-02 0.91967771 0.85137080 704.75 5.11952435e-02 5.12615114e-02 7.24478813e-02 0.78604495 0.86632592 705.00 6.02861566e-02 3.74311091e-02 7.09613177e-02 0.55563880 0.84180044 705.25 6.15731940e-02 2.72750292e-02 6.73437855e-02 0.41699176 0.80239463 705.50 5.77453426e-02 4.70903340e-03 5.79370312e-02 0.08136823 0.76287518 705.75 5.43230755e-02 -1.42295895e-04 5.43232619e-02 -0.00261943 0.72703147 706.00 5.36498212e-02 -1.35425910e-02 5.53326764e-02 -0.24726032 0.73975278 706.25 4.50857286e-02 -2.15116004e-02 4.99546983e-02 -0.44518202 0.71359104 706.50 3.18179450e-02 -2.63783949e-02 4.13303925e-02 -0.69220000 0.71444602 706.75 2.75930122e-02 -3.00809055e-02 4.08195442e-02 -0.82850867 0.57655857 707.00 2.18228093e-02 -3.92325538e-02 4.48935216e-02 -1.06317313 0.55778589 707.25 1.49195556e-02 -3.74967821e-02 4.03559390e-02 -1.19211114 0.47329228 707.50 6.65332266e-03 -4.01326589e-02 4.06804254e-02 -1.40650731 0.45908573 707.75 -1.11276635e-03 -5.41869678e-02 5.41983923e-02 -1.59132912 0.56731372 708.00 -1.08459551e-02 -6.23747299e-02 6.33106758e-02 -1.74295876 0.73331352 708.25 -1.55872991e-02 -6.12718433e-02 6.32234345e-02 -1.81990791 0.67958297 708.50 -3.26318067e-02 -4.90042753e-02 5.88748996e-02 -2.15826599 0.56728227 708.75 -3.28269115e-02 -5.46482518e-02 6.37498042e-02 -2.11172643 0.60213396 709.00 -3.69784180e-02 -5.61267991e-02 6.72132499e-02 -2.15335886 0.65717848 709.25 -3.30469533e-02 -6.12273630e-02 6.95765126e-02 -2.06572949 0.67202132 709.50 -3.19381533e-02 -6.42023382e-02 7.17076416e-02 -2.03241060 0.65891358 709.75 -4.11928848e-02 -7.07858148e-02 8.18992390e-02 -2.09782832 0.59608179 710.00 -6.40109791e-02 -6.93530743e-02 9.43782515e-02 -2.31615941 0.65737614 710.25 -8.62710156e-02 -7.22127940e-02 1.12505003e-01 -2.44466739 0.65403236 710.50 -1.05594571e-01 -6.48618321e-02 1.23924456e-01 -2.59075853 0.69945651 710.75 -1.36787786e-01 -3.51428367e-02 1.41230016e-01 -2.89011640 0.64417281 711.00 -1.44440933e-01 -1.59312845e-02 1.45316857e-01 -3.03174049 0.62247005 711.25 -1.64041796e-01 -1.15799757e-04 1.64041837e-01 -3.14088674 0.57304045 711.50 -1.82410130e-01 2.33060810e-02 1.83892982e-01 3.01451370 0.59631122 711.75 -1.91978552e-01 5.05713944e-02 1.98527656e-01 2.88402186 0.66025777 712.00 -1.73038435e-01 8.32620898e-02 1.92028320e-01 2.69311664 0.72060755 712.25 -1.44430456e-01 8.73231601e-02 1.68776453e-01 2.59779510 0.75503610 712.50 -1.34486838e-01 8.86906163e-02 1.61098526e-01 2.55858591 0.79583457 712.75 -1.29020964e-01 8.43145264e-02 1.54127702e-01 2.56276457 0.86106431 713.00 -1.27689751e-01 8.58616605e-02 1.53872991e-01 2.54961475 0.84160505 713.25 -1.14508432e-01 9.29837788e-02 1.47506488e-01 2.45956192 0.79325142 713.50 -1.07502344e-01 1.02552154e-01 1.48572199e-01 2.37975635 0.83093032 713.75 -9.73015580e-02 1.17930592e-01 1.52889561e-01 2.26064087 0.87707638 714.00 -9.46723851e-02 1.22640309e-01 1.54930649e-01 2.22819909 0.90291131 714.25 -9.25085419e-02 1.19077763e-01 1.50789071e-01 2.23127677 0.91266752 714.50 -8.76313189e-02 1.25176224e-01 1.52801620e-01 2.18156498 0.92247687 714.75 -8.28437492e-02 1.28894221e-01 1.53221431e-01 2.14204146 0.94392093 715.00 -8.14578428e-02 1.36955343e-01 1.59349133e-01 2.10736629 0.93573326 715.25 -8.29079597e-02 1.60592670e-01 1.80731114e-01 2.04736907 0.94253129 715.50 -7.13342851e-02 1.69549538e-01 1.83944628e-01 1.96904323 0.94434493 715.75 -4.39926435e-02 1.76830070e-01 1.82220269e-01 1.81463100 0.94321149 716.00 -2.69951803e-02 1.73935980e-01 1.76018365e-01 1.72476970 0.94120398 716.25 3.96574314e-03 1.78260462e-01 1.78304569e-01 1.54855309 0.95126757 716.50 1.99899659e-02 1.67797265e-01 1.68983788e-01 1.45222351 0.94159266 716.75 3.68516145e-02 1.46768794e-01 1.51324553e-01 1.32479565 0.96475343 717.00 3.82334485e-02 1.31505066e-01 1.36950279e-01 1.28785879 0.95082470 717.25 4.34921699e-02 1.20784448e-01 1.28376211e-01 1.22516915 0.96562477 717.50 4.79980072e-02 1.06910804e-01 1.17190992e-01 1.14881280 0.93471684 717.75 5.16944660e-02 8.30348927e-02 9.78116109e-02 1.01395126 0.92903380 718.00 4.53547365e-02 6.13530022e-02 7.62970707e-02 0.93421575 0.86620506 718.25 3.48295039e-02 4.81037111e-02 5.93890677e-02 0.94411095 0.86331129 718.50 1.87602886e-02 4.60271655e-02 4.97036054e-02 1.18376260 0.78147838 718.75 -4.53514567e-03 4.53451183e-02 4.55713429e-02 1.67047882 0.76849832 719.00 -1.23750305e-02 5.49104522e-02 5.62876465e-02 1.79246052 0.77393078 719.25 -1.95774070e-02 6.63064651e-02 6.91362581e-02 1.85789552 0.82660154 719.50 -1.24199170e-02 7.61905067e-02 7.71961635e-02 1.73238638 0.87250713 719.75 -6.83299714e-03 8.44770922e-02 8.47529879e-02 1.65150642 0.85373880 720.00 4.68799453e-03 8.37655591e-02 8.38966399e-02 1.51488899 0.79403784 720.25 1.34693548e-02 7.60130832e-02 7.71972302e-02 1.39541892 0.83567298 720.50 2.05809984e-02 6.90516693e-02 7.20535254e-02 1.28112751 0.89435845 720.75 2.24475874e-02 6.47069226e-02 6.84899994e-02 1.23687544 0.88190837 721.00 1.85194080e-02 6.04779524e-02 6.32499107e-02 1.27364520 0.91180716 721.25 1.68719804e-02 6.13544402e-02 6.36319971e-02 1.30243755 0.91477345 721.50 1.55190147e-02 6.10876125e-02 6.30280590e-02 1.32201406 0.89942598 721.75 1.50472803e-02 6.20538314e-02 6.38521623e-02 1.33290062 0.87823551 722.00 1.48840958e-02 6.48429093e-02 6.65292356e-02 1.34516407 0.86840611 722.25 1.10193226e-02 6.48932186e-02 6.58221489e-02 1.40259376 0.83697088 722.50 2.33400353e-02 6.53313206e-02 6.93753465e-02 1.22767165 0.80634218 722.75 3.33318964e-02 6.05799878e-02 6.91444158e-02 1.06778960 0.84825717 723.00 3.91947718e-02 4.43463334e-02 5.91846891e-02 0.84698517 0.79828281 723.25 3.73717506e-02 3.68964456e-02 5.25166206e-02 0.77899841 0.83009367 723.50 3.42766227e-02 2.65471786e-02 4.33548101e-02 0.65899642 0.73750015 723.75 3.17817898e-02 2.06055089e-02 3.78770268e-02 0.57520967 0.67893121 724.00 1.67509635e-02 1.76916850e-02 2.43637127e-02 0.81270407 0.55606004 724.25 1.26452258e-02 1.83065492e-02 2.22493029e-02 0.96630629 0.59392780 724.50 1.02611247e-02 1.92850315e-02 2.18449793e-02 1.08181750 0.57136366 724.75 6.48221799e-03 1.92726489e-02 2.03335718e-02 1.24633964 0.51870906 725.00 -5.40651771e-03 2.64233978e-02 2.69708432e-02 1.77262158 0.61324598 725.25 -1.20882325e-02 2.98135111e-02 3.21709622e-02 1.95600205 0.69593968 725.50 -1.60354158e-02 3.58878679e-02 3.93074246e-02 1.99100259 0.79360162 725.75 -1.32861530e-02 4.00701918e-02 4.22154253e-02 1.89096083 0.84350888 726.00 -9.42430055e-03 4.56481335e-02 4.66108306e-02 1.77439116 0.89122174 726.25 -7.12409086e-03 4.67040131e-02 4.72442325e-02 1.72216654 0.88657540 726.50 -3.48695811e-03 4.82562809e-02 4.83820992e-02 1.64293011 0.91032383 726.75 -4.52523100e-03 4.87025998e-02 4.89123803e-02 1.66344591 0.90831232 727.00 -1.75223208e-03 4.81336398e-02 4.81655229e-02 1.60718374 0.90403285 727.25 1.03501241e-03 4.50303697e-02 4.50422629e-02 1.54781561 0.89217471 727.50 -1.88981316e-04 4.12994056e-02 4.12998380e-02 1.57537218 0.91292992 727.75 -6.06504505e-04 3.93916243e-02 3.93962932e-02 1.58619190 0.90581164 728.00 -2.32604160e-03 3.41802289e-02 3.42592836e-02 1.63874382 0.87349580 728.25 -4.51886034e-03 3.33278636e-02 3.36328201e-02 1.70556254 0.86562221 728.50 -7.29356928e-03 2.66211548e-02 2.76022108e-02 1.83821070 0.73784977 728.75 -1.59820914e-02 2.16961630e-02 2.69471842e-02 2.20568698 0.67132936 729.00 -2.20198683e-02 1.90790845e-02 2.91356494e-02 2.42762649 0.72031719 729.25 -2.35208133e-02 1.61882895e-02 2.85532725e-02 2.53879361 0.58396405 729.50 -2.40849685e-02 1.28514861e-02 2.72992015e-02 2.65143592 0.46994473 729.75 -2.62197032e-02 9.33844134e-03 2.78330617e-02 2.79943958 0.37894328 730.00 -2.39027438e-02 2.04686651e-03 2.39902235e-02 3.05616794 0.31653774 730.25 -1.90756695e-02 -2.42954652e-03 1.92297650e-02 -3.01491107 0.17669431 730.50 -8.55424484e-03 -3.82944861e-05 8.55433055e-03 -3.13711602 0.05236569 730.75 -7.08648721e-03 -2.53334707e-04 7.09101399e-03 -3.10585889 0.05102534 731.00 -6.33963116e-03 9.75052214e-05 6.34038094e-03 3.12621360 0.03766547 731.25 -2.98430687e-03 1.07577786e-02 1.11640444e-02 1.84140098 0.13439182 731.50 9.36639731e-04 4.61097853e-03 4.70514792e-03 1.37039054 0.02333022 731.75 8.32707924e-03 -4.02367208e-03 9.24825311e-03 -0.45012017 0.07745219 732.00 1.29041272e-02 -1.45740390e-03 1.29861667e-02 -0.11246434 0.09826281 732.25 1.21239196e-02 -1.05925635e-03 1.21701047e-02 -0.08714784 0.05452192 732.50 1.97590680e-02 -7.50026338e-03 2.11346805e-02 -0.36278510 0.15038922 732.75 4.25285274e-02 -2.06009153e-02 4.72554055e-02 -0.45109174 0.43727168 733.00 5.15904203e-02 -2.88399206e-02 5.91042510e-02 -0.50973966 0.52841194 733.25 5.21456545e-02 -3.29368322e-02 6.16766098e-02 -0.56335375 0.71847698 733.50 4.46062181e-02 -3.28555120e-02 5.54003552e-02 -0.63484905 0.77527555 733.75 3.70491398e-02 -3.49487038e-02 5.09318237e-02 -0.75623284 0.65447288 734.00 3.85070268e-02 -3.74918996e-02 5.37441499e-02 -0.77204183 0.64803357 734.25 3.42716021e-02 -4.49183917e-02 5.64995984e-02 -0.91904291 0.76491026 734.50 2.72716974e-02 -4.70856856e-02 5.44133005e-02 -1.04581664 0.78895942 734.75 1.96900075e-02 -4.95170409e-02 5.32882138e-02 -1.19232519 0.80632338 735.00 1.79247412e-02 -4.61702974e-02 4.95276964e-02 -1.20047662 0.80978674 735.25 1.79003588e-02 -3.58617470e-02 4.00810148e-02 -1.10782967 0.80096676 735.50 1.72124881e-02 -3.09248778e-02 3.53923412e-02 -1.06290744 0.76501538 735.75 6.96562888e-03 -2.75997046e-02 2.84651309e-02 -1.32357840 0.68531777 736.00 3.18994808e-03 -2.26298859e-02 2.28536103e-02 -1.43075726 0.47811409 736.25 6.25933182e-03 -1.01238121e-02 1.19025546e-02 -1.01704531 0.18506630 736.50 5.24193646e-03 -2.76287875e-03 5.92548705e-03 -0.48507004 0.03466697 736.75 4.09643178e-03 9.35467941e-03 1.02122857e-02 1.15804861 0.07370207 737.00 7.65057326e-03 1.80315045e-02 1.95874048e-02 1.16952786 0.17199915 737.25 1.40467211e-02 3.59787391e-02 3.86235685e-02 1.19857812 0.36849269 737.50 1.60547453e-02 4.47520279e-02 4.75447037e-02 1.22634866 0.43491631 737.75 1.67330836e-02 5.94355953e-02 6.17461422e-02 1.29636661 0.59217792 738.00 6.71493067e-03 7.06963238e-02 7.10145090e-02 1.47609768 0.56600647 738.25 -1.27093628e-02 9.69413610e-02 9.77709331e-02 1.70115645 0.54844489 738.50 -2.49298654e-02 1.02662154e-01 1.05645710e-01 1.80901927 0.44642185 738.75 -3.60795409e-02 8.09373292e-02 8.86148099e-02 1.99012813 0.21408231 739.00 -5.34893810e-02 3.67475703e-02 6.48960538e-02 2.53964027 0.12696747 739.25 -5.24777127e-02 1.75492478e-02 5.53343151e-02 2.81887040 0.17915682 739.50 -5.28479501e-02 -2.32133502e-02 5.77214471e-02 -2.72771608 0.19576216 739.75 -6.74568127e-02 -1.76731200e-02 6.97334981e-02 -2.88535999 0.24978067 740.00 -6.83499958e-02 -1.67211536e-02 7.03656088e-02 -2.90166488 0.19654352 740.25 -7.42490903e-02 -6.42830214e-03 7.45268440e-02 -3.05523048 0.24282769 740.50 -8.65598801e-02 -4.77088513e-03 8.66912579e-02 -3.08653178 0.21238460 740.75 -1.04005881e-01 -1.92914776e-02 1.05779887e-01 -2.95819247 0.21498260 741.00 -1.02857762e-01 -8.32421709e-02 1.32321496e-01 -2.46121027 0.27894136 741.25 -1.06691131e-01 -1.27633376e-01 1.66352866e-01 -2.26705848 0.33675352 741.50 -1.08773361e-01 -1.45459390e-01 1.81631710e-01 -2.21288278 0.42598974 741.75 -1.15343320e-01 -1.43112712e-01 1.83807861e-01 -2.24916170 0.51846509 742.00 -1.19453550e-01 -1.54967232e-01 1.95662959e-01 -2.22749654 0.58805235 742.25 -1.00095559e-01 -1.52131734e-01 1.82107620e-01 -2.15274224 0.57805463 742.50 -1.21872490e-01 -1.65450714e-01 2.05491710e-01 -2.20567199 0.75233315 742.75 -1.30941899e-01 -1.64489051e-01 2.10243737e-01 -2.24312554 0.79179935 743.00 -1.06837948e-01 -1.39961266e-01 1.76078117e-01 -2.22278013 0.71661119 743.25 -9.74908990e-02 -1.09151921e-01 1.46351007e-01 -2.29982346 0.60463496 743.50 -9.91613688e-02 -8.88785679e-02 1.33162971e-01 -2.41082421 0.62632909 743.75 -8.26794819e-02 -8.79231396e-02 1.20691239e-01 -2.32546807 0.54572772 744.00 -6.81240856e-02 -1.08740296e-01 1.28317353e-01 -2.13046227 0.52427571 744.25 -7.05597821e-02 -1.23040570e-01 1.41836754e-01 -2.09147822 0.53315160 744.50 -3.50221901e-02 -1.68202001e-01 1.71809391e-01 -1.77607836 0.69992868 744.75 -4.15644797e-02 -1.70180079e-01 1.75182377e-01 -1.81034483 0.71632198 745.00 -6.63368222e-02 -1.64526258e-01 1.77396346e-01 -1.95405741 0.61625622 745.25 -5.41592211e-02 -1.79045626e-01 1.87057632e-01 -1.86453447 0.65958850 745.50 -8.11042525e-02 -2.06962237e-01 2.22286453e-01 -1.94428271 0.72512183 745.75 -1.44608066e-01 -2.02847661e-01 2.49115769e-01 -2.19012100 0.74262742 746.00 -1.88040236e-01 -1.58243358e-01 2.45764299e-01 -2.44203067 0.79598275 746.25 -2.08240232e-01 -1.36573098e-01 2.49030531e-01 -2.56112017 0.80554311 746.50 -1.53658979e-01 -6.53776114e-02 1.66988964e-01 -2.73932219 0.59833928 746.75 -1.15711579e-01 -3.86742413e-02 1.22003551e-01 -2.81903562 0.56332021 747.00 -7.61624502e-02 -3.07411906e-02 8.21324516e-02 -2.75796381 0.39589429 747.25 -3.70802247e-02 -4.81849251e-02 6.08007407e-02 -2.22668617 0.25809506 747.50 5.82212845e-03 -9.14350226e-02 9.16201972e-02 -1.50720714 0.55915666 747.75 -2.05342067e-02 -1.23281892e-01 1.24980313e-01 -1.73584418 0.66874569 748.00 -6.87531252e-02 -1.40302676e-01 1.56242866e-01 -2.02643965 0.70502808 748.25 -8.69830064e-02 -1.43546347e-01 1.67843967e-01 -2.11558494 0.72498481 748.50 -1.09404500e-01 -1.50081720e-01 1.85725247e-01 -2.20069934 0.83214177 748.75 -1.44865808e-01 -1.35097294e-01 1.98084278e-01 -2.39107249 0.86873142 749.00 -1.56686457e-01 -1.15011628e-01 1.94366459e-01 -2.50839480 0.92438200 749.25 -1.35395504e-01 -1.03576312e-01 1.70469924e-01 -2.48856628 0.88330186 749.50 -1.26343951e-01 -1.10635434e-01 1.67937468e-01 -2.42238409 0.83498929 749.75 -1.23675577e-01 -1.06057861e-01 1.62923044e-01 -2.43273233 0.54977856 750.00 -1.56866661e-01 -9.66012980e-02 1.84225297e-01 -2.58962346 0.40506138 750.25 -1.44457168e-01 -9.16867681e-02 1.71097448e-01 -2.57604941 0.52248459 750.50 -1.44368342e-01 -8.67645851e-02 1.68434888e-01 -2.60044220 0.81553474 750.75 -1.51805895e-01 -1.03746995e-01 1.83870794e-01 -2.54208194 0.87442747 751.00 -1.62539794e-01 -1.04082571e-01 1.93008720e-01 -2.57203027 0.93781390 751.25 -1.95147543e-01 -9.13299159e-02 2.15461637e-01 -2.70386752 0.93551746 751.50 -2.04694831e-01 -8.81284137e-02 2.22860026e-01 -2.73504266 0.95722316 751.75 -2.18199082e-01 -6.95057584e-02 2.29001942e-01 -2.83321206 0.95354028 752.00 -2.29182082e-01 -5.89702583e-02 2.36647244e-01 -2.88974830 0.96957876 752.25 -2.32504679e-01 -2.94782222e-02 2.34365935e-01 -3.01548002 0.93778306 752.50 -2.32229283e-01 -6.84657497e-03 2.32330186e-01 -3.11211923 0.94493265 752.75 -2.32419977e-01 1.01783177e-02 2.32642739e-01 3.09782783 0.90622401 753.00 -2.42957007e-01 2.95861488e-02 2.44751808e-01 3.02041405 0.85202385 753.25 -1.88778092e-01 9.51104190e-02 2.11383916e-01 2.67489270 0.71237681 753.50 -1.48603985e-01 1.25634449e-01 1.94594860e-01 2.43975699 0.66771644 753.75 -1.06321611e-01 1.14509118e-01 1.56258193e-01 2.31913552 0.52458337 754.00 -1.02001253e-01 8.68645919e-02 1.33976539e-01 2.43616859 0.42285155 754.25 -1.13236789e-01 7.13567699e-02 1.33844533e-01 2.57929470 0.45099433 754.50 -1.10987910e-01 8.55186612e-02 1.40113374e-01 2.48508612 0.40177864 754.75 -7.50978775e-02 9.68511735e-02 1.22555461e-01 2.23035288 0.33230205 755.00 -6.77931718e-02 7.47287547e-02 1.00897477e-01 2.30756958 0.24104420 755.25 -5.47365978e-02 4.96950353e-03 5.49617239e-02 3.05105147 0.05973727 755.50 -2.97532316e-02 -1.75185722e-02 3.45276000e-02 -2.60945241 0.02648428 755.75 -8.12960415e-02 -5.99769191e-02 1.01026121e-01 -2.50597166 0.26428766 756.00 -1.08149207e-01 -6.07858656e-02 1.24061164e-01 -2.62954085 0.31569223 756.25 -1.41668068e-01 1.57001602e-02 1.42535387e-01 3.03121948 0.40885657 756.50 -1.28669115e-01 1.20609566e-02 1.29233153e-01 3.04812953 0.51355938 756.75 -1.38979607e-01 3.95280337e-03 1.39035808e-01 3.11315871 0.57512241 757.00 -1.50621833e-01 1.07459918e-02 1.51004678e-01 3.07036915 0.52340487 757.25 -1.55475060e-01 3.90726624e-02 1.60309598e-01 2.89538007 0.59819388 757.50 -1.69015568e-01 6.26586018e-02 1.80256380e-01 2.78657360 0.70390845 757.75 -1.73024977e-01 1.11059264e-01 2.05601077e-01 2.57095511 0.80478712 758.00 -1.57353700e-01 1.35524868e-01 2.07670837e-01 2.43058896 0.85013840 758.25 -1.46950565e-01 1.63306016e-01 2.19689151e-01 2.30352735 0.90479123 758.50 -1.35725514e-01 1.70345493e-01 2.17804963e-01 2.24356227 0.91706309 758.75 -1.31373313e-01 1.81928294e-01 2.24403324e-01 2.19621149 0.91779251 759.00 -1.26697404e-01 2.19948632e-01 2.53829929e-01 2.09340568 0.93248572 759.25 -1.20967382e-01 2.61456456e-01 2.88084338e-01 2.00413440 0.95950361 759.50 -8.95585165e-02 2.97233637e-01 3.10432864e-01 1.86345159 0.92601086 759.75 -3.28637510e-03 3.39844151e-01 3.39860041e-01 1.58046627 0.90330000 760.00 8.67840894e-02 3.04304855e-01 3.16437866e-01 1.29298331 0.85383068 760.25 1.74531179e-01 2.33843405e-01 2.91794226e-01 0.92962940 0.88070441 760.50 1.71605033e-01 1.59017653e-01 2.33954913e-01 0.74734480 0.81785536 760.75 1.60157212e-01 7.46835873e-02 1.76714376e-01 0.43633771 0.77675637 761.00 1.33050871e-01 3.82068527e-02 1.38427952e-01 0.27963551 0.64669898 761.25 9.37641234e-02 1.76813424e-02 9.54166689e-02 0.18638390 0.52184054 761.50 5.60747910e-02 1.13140840e-02 5.72048135e-02 0.19909473 0.21160929 761.75 2.18594979e-02 1.30355779e-03 2.18983313e-02 0.05956294 0.04218966 762.00 1.71136613e-02 9.40948060e-03 1.95298676e-02 0.50270713 0.04264612 762.25 2.09195968e-02 1.31667162e-02 2.47182512e-02 0.56175443 0.06693555 762.50 4.25198995e-02 6.06382980e-02 7.40604147e-02 0.95926185 0.35522534 762.75 4.80533785e-02 7.45003035e-02 8.86533835e-02 0.99793761 0.46359877 763.00 6.13703379e-02 7.92001154e-02 1.00194694e-01 0.91156319 0.51982557 763.25 7.69988215e-02 7.16714898e-02 1.05193255e-01 0.74958030 0.54441020 763.50 9.45063120e-02 5.53232697e-02 1.09508480e-01 0.52960931 0.61174695 763.75 9.48388554e-02 4.49974681e-02 1.04972285e-01 0.44300959 0.60897474 764.00 1.03195739e-01 2.51225872e-02 1.06209721e-01 0.23880072 0.74714030 764.25 1.05644225e-01 2.63588568e-02 1.08882926e-01 0.24451357 0.78452506 764.50 9.99931826e-02 2.38900673e-02 1.02807451e-01 0.23452068 0.78539989 764.75 1.00605673e-01 2.41398917e-02 1.03461277e-01 0.23549357 0.83411859 765.00 1.00357845e-01 2.76046494e-02 1.04085127e-01 0.26842403 0.86152056 765.25 9.68266719e-02 1.90913071e-02 9.86908425e-02 0.19467285 0.87184209 765.50 8.65085324e-02 1.00787636e-02 8.70936717e-02 0.11598312 0.90371782 765.75 8.25618126e-02 1.04152794e-02 8.32161700e-02 0.12548841 0.89979546 766.00 7.03735454e-02 1.96163729e-02 7.30564027e-02 0.27184587 0.82976391 766.25 6.07431591e-02 2.14080108e-02 6.44052350e-02 0.33884237 0.84708142 766.50 5.02888347e-02 2.65695077e-02 5.68762308e-02 0.48606025 0.87430344 766.75 4.09778210e-02 3.38382104e-02 5.31432620e-02 0.69025738 0.82107199 767.00 2.79935022e-02 5.36795255e-02 6.05402976e-02 1.09010245 0.78948422 767.25 2.58899451e-02 7.04454477e-02 7.50523175e-02 1.21860161 0.78638697 767.50 2.71163357e-02 1.06847365e-01 1.10234546e-01 1.32225782 0.84448819 767.75 4.49712297e-02 1.20402612e-01 1.28527042e-01 1.21333515 0.85737467 768.00 7.54824302e-02 1.40493630e-01 1.59486856e-01 1.07778235 0.90086139 768.25 8.65073497e-02 1.46953773e-01 1.70525461e-01 1.03874900 0.89029951 768.50 1.26602433e-01 1.43252817e-01 1.91179355e-01 0.84702121 0.86519795 768.75 1.50995315e-01 1.31171464e-01 2.00013845e-01 0.71525762 0.88795430 769.00 1.70314784e-01 1.10294661e-01 2.02908940e-01 0.57468126 0.90602116 769.25 1.74796181e-01 9.21388537e-02 1.97593708e-01 0.48510878 0.90303364 769.50 1.70097330e-01 8.54428231e-02 1.90351196e-01 0.46549969 0.91632516 769.75 1.65298656e-01 9.41326229e-02 1.90222492e-01 0.51766839 0.92309756 770.00 1.68698003e-01 1.10026372e-01 2.01407097e-01 0.57792662 0.92618907 770.25 1.76644128e-01 1.23335893e-01 2.15441153e-01 0.60952816 0.86048225 770.50 2.24418680e-01 1.49631521e-01 2.69728263e-01 0.58806142 0.84893131 770.75 2.85886398e-01 1.34463285e-01 3.15929434e-01 0.43963784 0.81917891 771.00 3.33986117e-01 7.30458580e-02 3.41880716e-01 0.21531882 0.80521693 771.25 3.32320787e-01 4.80185331e-03 3.32355477e-01 0.01444845 0.79995821 771.50 3.61471359e-01 -5.25173355e-02 3.65266497e-01 -0.14427817 0.87964693 771.75 3.75820160e-01 -7.28183439e-02 3.82809749e-01 -0.19138696 0.87311797 772.00 3.68678319e-01 -7.89310431e-02 3.77032907e-01 -0.21090802 0.88274601 772.25 3.44233933e-01 -1.29576557e-01 3.67813926e-01 -0.36001507 0.81813827 772.50 3.42860339e-01 -2.07171332e-01 4.00591029e-01 -0.54353431 0.82992678 772.75 2.92848620e-01 -2.47221932e-01 3.83247959e-01 -0.70111547 0.78868439 773.00 2.37737093e-01 -2.56008564e-01 3.49369876e-01 -0.82238712 0.82183457 773.25 2.04528883e-01 -2.51918441e-01 3.24491856e-01 -0.88885014 0.82861998 773.50 1.75101971e-01 -2.68660153e-01 3.20685169e-01 -0.99318477 0.82769528 773.75 1.48275604e-01 -3.16889858e-01 3.49864027e-01 -1.13314952 0.82975966 774.00 1.19047413e-01 -3.23859032e-01 3.45046315e-01 -1.21853767 0.84043733 774.25 3.25366894e-02 -3.22838383e-01 3.24473817e-01 -1.47035228 0.84045394 774.50 -5.38110133e-03 -3.23173935e-01 3.23218732e-01 -1.58744558 0.85602804 774.75 -6.27045358e-02 -2.80770038e-01 2.87686762e-01 -1.79052122 0.86369029 775.00 -8.82863597e-02 -2.55458470e-01 2.70284131e-01 -1.90354565 0.86243413 775.25 -9.97625833e-02 -1.81102269e-01 2.06762194e-01 -2.07430206 0.63846645 775.50 -9.97466157e-02 -1.48719047e-01 1.79071891e-01 -2.16158952 0.65101743 775.75 -1.26180794e-01 -1.05000150e-01 1.64154270e-01 -2.44755875 0.72394060 776.00 -1.37558880e-01 -7.46599263e-02 1.56513738e-01 -2.64433357 0.76449008 776.25 -1.39246691e-01 -4.12984861e-02 1.45241887e-01 -2.85327178 0.71871987 776.50 -1.31769671e-01 -3.39691161e-02 1.36077724e-01 -2.88929426 0.67526836 776.75 -1.23769608e-01 -7.67786415e-03 1.24007521e-01 -3.07963852 0.67166216 777.00 -1.30349099e-01 1.48321401e-02 1.31190244e-01 3.02829215 0.64469277 777.25 -1.09276925e-01 3.46632309e-02 1.14642862e-01 2.83442677 0.60418587 777.50 -1.11679943e-01 3.79371411e-02 1.17947600e-01 2.81412738 0.62556780 777.75 -1.05572654e-01 6.07078515e-02 1.21782710e-01 2.61973292 0.59252204 778.00 -8.65571624e-02 8.61983574e-02 1.22156863e-01 2.35827144 0.60873984 778.25 -7.82428333e-02 1.14569867e-01 1.38737865e-01 2.16997164 0.68593978 778.50 -6.49532552e-02 1.41002546e-01 1.55243819e-01 2.00247395 0.68760284 778.75 -2.40073157e-02 1.67458473e-01 1.69170598e-01 1.71318889 0.71388087 779.00 -8.42721698e-03 1.76874064e-01 1.77074709e-01 1.61840562 0.75230210 779.25 3.78519379e-03 1.89538352e-01 1.89576145e-01 1.55082839 0.80457401 779.50 1.41435437e-02 1.85102104e-01 1.85641668e-01 1.49453509 0.78048907 779.75 4.66043068e-02 1.69125738e-01 1.75429407e-01 1.30190946 0.75070686 780.00 7.90448334e-02 1.73160100e-01 1.90348380e-01 1.14256332 0.74490061 780.25 1.18030609e-01 1.47750128e-01 1.89106650e-01 0.89675526 0.78010007 780.50 1.22345675e-01 1.21793854e-01 1.72633158e-01 0.78313790 0.73149798 780.75 1.14251276e-01 1.05510206e-01 1.55517709e-01 0.74564386 0.68252464 781.00 1.09940759e-01 1.09625840e-01 1.55257191e-01 0.78396389 0.64233884 781.25 1.09521398e-01 1.18258156e-01 1.61182902e-01 0.82373557 0.58820916 781.50 1.25890239e-01 1.37995620e-01 1.86791712e-01 0.83123958 0.54066444 781.75 1.77544668e-01 1.55614374e-01 2.36088845e-01 0.71966769 0.61871863 782.00 2.04903770e-01 1.36124588e-01 2.45998899e-01 0.58638610 0.66853580 782.25 2.28427879e-01 1.10326046e-01 2.53675250e-01 0.44993895 0.67902904 782.50 2.13611159e-01 4.18276842e-02 2.17667826e-01 0.19336566 0.60704745 782.75 1.83086731e-01 -3.12113628e-03 1.83113333e-01 -0.01704566 0.55464775 783.00 1.29005643e-01 -2.42645526e-03 1.29028461e-01 -0.01880669 0.46441750 783.25 1.01330609e-01 8.30631544e-03 1.01670483e-01 0.08178955 0.40536723 783.50 7.03459570e-02 5.45049377e-02 8.89906843e-02 0.65919301 0.36779540 783.75 5.86765116e-02 9.00499542e-02 1.07479892e-01 0.99329745 0.47828248 784.00 3.78599469e-02 1.42808543e-01 1.47741854e-01 1.31164799 0.59612286 784.25 5.54447787e-02 1.66080807e-01 1.75091285e-01 1.24858788 0.68107287 784.50 9.41902924e-02 2.00288001e-01 2.21330284e-01 1.13121082 0.83048704 784.75 1.05166460e-01 2.16615234e-01 2.40794817e-01 1.11881674 0.87118893 785.00 1.40800809e-01 2.21952069e-01 2.62845180e-01 1.00548394 0.89053242 785.25 1.52558370e-01 2.19516806e-01 2.67323183e-01 0.96345180 0.90384146 785.50 1.71912577e-01 2.55994595e-01 3.08362071e-01 0.97942217 0.87191415 785.75 1.88597584e-01 2.59233036e-01 3.20578876e-01 0.94183741 0.86985007 786.00 2.01247668e-01 2.46838557e-01 3.18480607e-01 0.88679503 0.83743195 786.25 2.04536514e-01 2.71962925e-01 3.40292548e-01 0.92596855 0.80126288 786.50 2.79798638e-01 3.36557087e-01 4.37673338e-01 0.87722634 0.75330127 786.75 3.29850165e-01 3.34398400e-01 4.69705675e-01 0.79224524 0.74539576 787.00 4.49155790e-01 3.11249892e-01 5.46458982e-01 0.60598984 0.62004781 787.25 5.03715859e-01 2.52886630e-01 5.63632250e-01 0.46528005 0.52785514 787.50 6.07787359e-01 3.31288539e-02 6.08689571e-01 0.05445342 0.55222129 787.75 6.35542645e-01 -5.84448403e-02 6.38224297e-01 -0.09170261 0.52099218 788.00 3.79076098e-01 -3.68398928e-01 5.28598579e-01 -0.77111482 0.28981687 788.25 2.33202187e-01 -5.31475901e-01 5.80387709e-01 -1.15731015 0.32806952 788.50 -2.13147535e-01 -6.33833513e-01 6.68712789e-01 -1.89519937 0.50250201 788.75 -4.08720524e-01 -3.98112723e-01 5.70566567e-01 -2.36934118 0.50837477 789.00 -4.78596671e-01 -6.14127559e-02 4.82520777e-01 -3.01397166 0.53540475 789.25 -3.76646213e-01 1.22851242e-01 3.96175210e-01 2.82630158 0.38853129 789.50 -1.86303430e-01 3.00493047e-01 3.53560517e-01 2.12578662 0.34497455 789.75 4.27590458e-03 2.87016709e-01 2.87048558e-01 1.55589967 0.31261164 790.00 1.45951912e-01 2.83316669e-01 3.18700950e-01 1.09509860 0.40453160 790.25 1.96483543e-01 2.10765733e-01 2.88145756e-01 0.82045369 0.34753000 790.50 2.49358746e-01 1.62625609e-01 2.97702659e-01 0.57790289 0.34843139 790.75 2.47181997e-01 1.04864006e-02 2.47404334e-01 0.04239838 0.31582361 791.00 2.79197654e-01 -1.08753079e-01 2.99630710e-01 -0.37143940 0.49182035 791.25 2.72110776e-01 -1.64631623e-01 3.18037491e-01 -0.54410025 0.49558218 791.50 2.62589725e-01 -2.04206766e-01 3.32646610e-01 -0.66097272 0.48396204 791.75 2.61662302e-01 -1.46461340e-01 2.99863443e-01 -0.51028596 0.54416417 792.00 2.29819301e-01 -1.23565074e-01 2.60931482e-01 -0.49332123 0.58262690 792.25 1.96512999e-01 -1.32917513e-01 2.37243386e-01 -0.59469728 0.54064037 792.50 1.99330693e-01 -1.57302243e-01 2.53922667e-01 -0.66809130 0.60020266 792.75 1.78956343e-01 -1.49013640e-01 2.32874295e-01 -0.69435348 0.55093561 793.00 1.80943356e-01 -1.22199128e-01 2.18341762e-01 -0.59398640 0.58798117 793.25 1.69884484e-01 -1.35258794e-01 2.17153584e-01 -0.67240792 0.62652872 793.50 1.38764268e-01 -1.47061630e-01 2.02194573e-01 -0.81441944 0.68911353 793.75 1.26063538e-01 -1.31689236e-01 1.82302141e-01 -0.80722064 0.74188038 794.00 1.24435150e-01 -1.08188282e-01 1.64890300e-01 -0.71566947 0.73972100 794.25 1.24335374e-01 -1.03226866e-01 1.61601581e-01 -0.69290357 0.74023670 794.50 1.28304124e-01 -1.00083786e-01 1.62722808e-01 -0.66245813 0.75650456 794.75 1.15855081e-01 -1.32172264e-01 1.75760938e-01 -0.85109134 0.78732628 795.00 1.04329640e-01 -1.40877226e-01 1.75302786e-01 -0.93335690 0.82945535 795.25 5.89760643e-02 -1.51528779e-01 1.62601190e-01 -1.19962873 0.85493901 795.50 3.84700064e-02 -1.48742011e-01 1.53636347e-01 -1.31770653 0.88632050 795.75 4.77146974e-03 -1.18944356e-01 1.19040021e-01 -1.53070268 0.80256321 796.00 -8.21514164e-03 -1.05486766e-01 1.05806173e-01 -1.64851786 0.75921931 796.25 -1.20614794e-02 -9.53770012e-02 9.61366301e-02 -1.69658967 0.74830597 796.50 -1.65473874e-02 -9.36231720e-02 9.50742571e-02 -1.74573422 0.72735129 796.75 -3.26839432e-02 -8.75603301e-02 9.34614977e-02 -1.92805242 0.64124893 797.00 -3.43632337e-02 -7.97689441e-02 8.68557210e-02 -1.97755637 0.62444116 797.25 -6.02661546e-02 -4.43179810e-02 7.48070373e-02 -2.50752005 0.50768584 797.50 -7.07931926e-02 -4.19200896e-02 8.22737505e-02 -2.60696625 0.52168682 797.75 -6.34982147e-02 -2.44092036e-02 6.80281743e-02 -2.77459974 0.38192360 798.00 -5.87673465e-02 -1.49667859e-02 6.06432659e-02 -2.89221547 0.30783123 798.25 -8.45998798e-02 -1.40752283e-02 8.57627642e-02 -2.97672866 0.40674521 798.50 -9.30126870e-02 -1.31242837e-02 9.39340554e-02 -3.00141598 0.43665186 798.75 -1.18711990e-01 1.39243291e-02 1.19525828e-01 3.02483112 0.70021843 799.00 -1.23698872e-01 2.15825490e-02 1.25567580e-01 2.96885495 0.76192977 799.25 -1.40386865e-01 3.43542035e-02 1.44529178e-01 2.90159808 0.82166310 799.50 -1.52931433e-01 5.06916625e-02 1.61113835e-01 2.82152310 0.79392159 799.75 -1.91749878e-01 7.66777489e-02 2.06512694e-01 2.76118610 0.85991429 800.00 -2.13696859e-01 1.11694829e-01 2.41126694e-01 2.65996701 0.87807432 800.25 -2.31357714e-01 1.64348056e-01 2.83789844e-01 2.52394519 0.93519682 800.50 -2.30441666e-01 1.95448444e-01 3.02164617e-01 2.43817524 0.92922601 800.75 -2.26635012e-01 2.55229053e-01 3.41328724e-01 2.29692353 0.91691328 801.00 -1.91308121e-01 3.07151228e-01 3.61857256e-01 2.12784569 0.90690807 801.25 -1.46580390e-01 3.63997474e-01 3.92402818e-01 1.95362483 0.93112553 801.50 -9.42315221e-02 3.81446851e-01 3.92913833e-01 1.81298444 0.92115628 801.75 -5.29864246e-02 3.81369935e-01 3.85033230e-01 1.70884963 0.94065393 802.00 -2.57907285e-02 3.56748331e-01 3.57679373e-01 1.64296468 0.92720633 802.25 5.81543045e-03 3.62736802e-01 3.62783416e-01 1.55476561 0.95040816 802.50 2.47585928e-02 3.76787569e-01 3.77600133e-01 1.50518097 0.95361411 802.75 4.69461376e-02 3.79626691e-01 3.82518450e-01 1.44775704 0.95575032 803.00 6.56220030e-02 3.79197134e-01 3.84833358e-01 1.39943838 0.95508564 803.25 8.05788746e-02 3.83483259e-01 3.91857582e-01 1.36368578 0.96852562 803.50 9.34931515e-02 3.91310675e-01 4.02324513e-01 1.33626986 0.97382215 803.75 9.96715856e-02 3.98884661e-01 4.11148875e-01 1.32593465 0.97930531 804.00 1.28234215e-01 4.10995987e-01 4.30536543e-01 1.26835935 0.97674295 804.25 1.47100838e-01 4.21187244e-01 4.46136023e-01 1.23478729 0.97892487 804.50 1.94035542e-01 4.37401001e-01 4.78507500e-01 1.15326886 0.97642235 804.75 2.29819797e-01 4.47836908e-01 5.03363720e-01 1.09666243 0.97416274 805.00 3.26740123e-01 4.48972997e-01 5.55279983e-01 0.94168791 0.97186797 805.25 3.76896401e-01 4.34158474e-01 5.74929976e-01 0.85588318 0.97748327 805.50 4.77408497e-01 3.53323118e-01 5.93932739e-01 0.63712559 0.96658614 805.75 5.18751068e-01 2.94491699e-01 5.96513228e-01 0.51632605 0.97160253 806.00 5.30191985e-01 1.60840700e-01 5.54051687e-01 0.29453937 0.96302036 806.25 5.35657081e-01 7.66283088e-02 5.41110345e-01 0.14209074 0.95835919 806.50 4.74435365e-01 -4.07171303e-02 4.76179378e-01 -0.08561251 0.95644297 806.75 4.20437472e-01 -9.40658120e-02 4.30831805e-01 -0.22010834 0.94436372 807.00 3.21638578e-01 -1.44957324e-01 3.52794558e-01 -0.42342250 0.93719801 807.25 2.75628227e-01 -1.48884562e-01 3.13269105e-01 -0.49526056 0.93353105 807.50 1.85589805e-01 -1.48052059e-01 2.37408905e-01 -0.67336021 0.87597735 807.75 1.41763159e-01 -1.34076852e-01 1.95124052e-01 -0.75754028 0.84841997 808.00 5.55800196e-02 -1.06208984e-01 1.19872794e-01 -1.08867659 0.67609444 808.25 2.07601532e-02 -8.84594466e-02 9.08628508e-02 -1.34028239 0.59658721 808.50 2.20333468e-04 -2.65917546e-02 2.65926674e-02 -1.56251073 0.10004120 808.75 -1.00217340e-03 9.28028367e-03 9.33423893e-03 1.67836898 0.01606542 809.00 -2.44904154e-02 5.83938274e-02 6.33215566e-02 1.96791482 0.49284294 809.25 -2.48888913e-02 8.09250081e-02 8.46658954e-02 1.86916983 0.66125270 809.50 -1.24748573e-02 1.04738003e-01 1.05478298e-01 1.68934322 0.79890388 809.75 -7.07375005e-03 1.25924990e-01 1.26123515e-01 1.62691167 0.83517856 810.00 2.30365193e-03 1.50798702e-01 1.50816297e-01 1.55552118 0.85194137 810.25 2.49377069e-02 1.71511613e-01 1.73315097e-01 1.42640863 0.86613258 810.50 4.72097519e-02 1.98694484e-01 2.04225999e-01 1.33752214 0.91978819 810.75 6.70548144e-02 2.03208803e-01 2.13986368e-01 1.25206692 0.91261622 811.00 1.03780411e-01 2.11831262e-01 2.35887382e-01 1.11524504 0.89487739 811.25 1.31672049e-01 2.14829752e-01 2.51970932e-01 1.02093570 0.88594408 811.50 1.73957273e-01 2.12220089e-01 2.74405720e-01 0.88415677 0.90177468 811.75 2.21541354e-01 1.72717665e-01 2.80912733e-01 0.66218885 0.88828944 812.00 2.56300701e-01 1.19816467e-01 2.82924081e-01 0.43729809 0.90132186 812.25 2.56613537e-01 6.24959266e-02 2.64114082e-01 0.23889046 0.85629057 812.50 2.50086371e-01 3.36413959e-03 2.50108997e-01 0.01345110 0.85511928 812.75 1.93465207e-01 -4.23262633e-02 1.98041154e-01 -0.21538606 0.66897575 813.00 1.34165325e-01 -7.40127123e-02 1.53226030e-01 -0.50411147 0.60269808 813.25 6.47487232e-02 -6.56823218e-02 9.22310389e-02 -0.79255584 0.35410579 813.50 1.98032706e-02 -6.09141491e-02 6.40523465e-02 -1.25647279 0.25222014 813.75 -1.37322897e-02 -1.10039738e-02 1.75972504e-02 -2.46604667 0.02483881 814.00 -2.88860573e-02 2.07562004e-02 3.55699896e-02 2.51852238 0.17396156 814.25 -2.56817259e-02 2.76268928e-02 3.77199716e-02 2.31972188 0.34854257 814.50 -3.16365407e-02 2.68357969e-02 4.14853070e-02 2.43811357 0.52648149 814.75 -5.70256194e-02 3.48973971e-02 6.68561859e-02 2.59242543 0.66263876 815.00 -7.57336922e-02 4.76989853e-02 8.95029907e-02 2.57953108 0.80133471 815.25 -8.29256833e-02 7.91331612e-02 1.14624283e-01 2.37959235 0.85391565 815.50 -8.51372347e-02 9.88426742e-02 1.30453911e-01 2.28183761 0.87613760 815.75 -7.99811089e-02 1.26186427e-01 1.49398769e-01 2.13572219 0.89752737 816.00 -8.32356041e-02 1.44568797e-01 1.66818173e-01 2.09319469 0.90773909 816.25 -6.87452710e-02 1.77100461e-01 1.89974961e-01 1.94106392 0.91460421 816.50 -5.69034663e-02 1.88311727e-01 1.96721405e-01 1.86424914 0.93653102 816.75 -4.51122976e-02 1.98064284e-01 2.03136850e-01 1.79474187 0.94717048 817.00 -4.64779529e-02 2.08887566e-01 2.13995830e-01 1.78973210 0.95718839 817.25 -5.00028740e-02 2.37062676e-01 2.42278764e-01 1.77867602 0.94503287 817.50 -3.72885259e-02 2.54168209e-01 2.56888911e-01 1.71646523 0.94297846 817.75 -1.31362592e-02 2.83133353e-01 2.83437924e-01 1.61715909 0.96452378 818.00 -2.88467940e-03 2.91347103e-01 2.91361383e-01 1.58069718 0.96366099 818.25 3.07420160e-02 3.08698709e-01 3.10225667e-01 1.47153776 0.95609077 818.50 4.29921019e-02 3.26631448e-01 3.29448667e-01 1.43992596 0.96845061 818.75 6.40003400e-02 3.36338095e-01 3.42373127e-01 1.38275862 0.97213352 819.00 7.74245656e-02 3.43676735e-01 3.52290025e-01 1.34921243 0.96225832 819.25 9.87151541e-02 3.68405589e-01 3.81401835e-01 1.30899397 0.93640517 819.50 1.18454866e-01 3.88870952e-01 4.06512205e-01 1.27511347 0.90778943 819.75 1.63600922e-01 4.34539736e-01 4.64316749e-01 1.21071787 0.84266464 820.00 1.65451962e-01 4.63624268e-01 4.92261936e-01 1.22801752 0.70012398 820.25 1.76488862e-01 3.33877147e-01 3.77653634e-01 1.08452808 0.25284326 820.50 2.80117974e-01 4.35667309e-02 2.83485696e-01 0.15429376 0.12033989 820.75 3.56110489e-01 -2.93771942e-01 4.61645572e-01 -0.68976794 0.29448283 821.00 1.86071441e-01 -2.82718288e-01 3.38455627e-01 -0.98871209 0.32382752 821.25 4.24330912e-02 -3.19175720e-01 3.21984017e-01 -1.43862552 0.56089429 821.50 -7.60043103e-03 -3.34574598e-01 3.34660915e-01 -1.59350912 0.55680583 821.75 -9.60597549e-02 -2.94160365e-01 3.09447567e-01 -1.88643469 0.70047208 822.00 -1.48954388e-01 -2.21023899e-01 2.66531375e-01 -2.16380978 0.69235160 822.25 -1.81383089e-01 -1.39848396e-01 2.29035803e-01 -2.48477942 0.77407632 822.50 -1.75606424e-01 -7.38402011e-02 1.90499322e-01 -2.74355084 0.71532701 822.75 -1.68394758e-01 -1.97854500e-02 1.69553114e-01 -3.02463443 0.84358707 823.00 -1.61448689e-01 1.16514357e-02 1.61868573e-01 3.06954951 0.82914518 823.25 -1.44469885e-01 4.86500318e-02 1.52441377e-01 2.81677151 0.87015472 823.50 -1.41446064e-01 6.36392765e-02 1.55103019e-01 2.71880606 0.92538606 823.75 -1.40137293e-01 7.52894401e-02 1.59081617e-01 2.64858722 0.95340954 824.00 -1.23415701e-01 9.16869622e-02 1.53746331e-01 2.50264354 0.95310859 824.25 -1.15371679e-01 9.57007939e-02 1.49897520e-01 2.44912101 0.96698284 824.50 -1.02995831e-01 1.08183667e-01 1.49371507e-01 2.33163343 0.95407074 824.75 -9.53013477e-02 1.16161106e-01 1.50252286e-01 2.25786739 0.97940943 825.00 -8.72979268e-02 1.21413297e-01 1.49539683e-01 2.19417007 0.98337379 825.25 -8.34845686e-02 1.24246875e-01 1.49689543e-01 2.16243041 0.98536297 825.50 -8.14797634e-02 1.29034017e-01 1.52606453e-01 2.13402724 0.98016944 825.75 -8.19631434e-02 1.35309262e-01 1.58197830e-01 2.11543065 0.98381182 826.00 -7.91395959e-02 1.47816847e-01 1.67669007e-01 2.06235315 0.98455674 826.25 -7.40873835e-02 1.57214239e-01 1.73796597e-01 2.01118146 0.98159834 826.50 -5.01964349e-02 1.67029638e-01 1.74409237e-01 1.86273390 0.96960919 826.75 -3.70405901e-02 1.66189485e-01 1.70267290e-01 1.79009360 0.97810019 827.00 -2.13042723e-02 1.55910824e-01 1.57359642e-01 1.70659924 0.97658981 827.25 -1.95736985e-02 1.49221308e-01 1.50499596e-01 1.70122395 0.98540881 827.50 -2.55975353e-02 1.41069430e-01 1.43373002e-01 1.75029675 0.98735100 827.75 -3.01632956e-02 1.39704788e-01 1.42923939e-01 1.78343962 0.98789950 828.00 -3.68813154e-02 1.48253955e-01 1.52772597e-01 1.81461815 0.98587329 828.25 -3.89254800e-02 1.54916027e-01 1.59731551e-01 1.81696829 0.98601541 828.50 -3.41875835e-02 1.71568687e-01 1.74941720e-01 1.76748477 0.98707407 828.75 -3.06806423e-02 1.77759343e-01 1.80387599e-01 1.74170898 0.98577653 829.00 -1.52326265e-02 1.90421183e-01 1.91029474e-01 1.65062074 0.98457067 829.25 -4.28720849e-03 1.92503895e-01 1.92551629e-01 1.59306341 0.98651429 829.50 1.79457876e-02 1.90947688e-01 1.91789131e-01 1.47708883 0.98819191 829.75 2.78013122e-02 1.86596443e-01 1.88656157e-01 1.42289268 0.98818212 830.00 3.78965634e-02 1.81793029e-01 1.85700983e-01 1.36527960 0.98805761 830.25 4.59688087e-02 1.74638156e-01 1.80586868e-01 1.31341157 0.97964003 830.50 6.10912609e-02 1.55621498e-01 1.67183112e-01 1.19671745 0.97297120 830.75 6.29692807e-02 1.43035987e-01 1.56283153e-01 1.15609356 0.97031461 831.00 6.27169413e-02 1.30652768e-01 1.44926052e-01 1.12325388 0.97738500 831.25 6.44088243e-02 1.23066856e-01 1.38902656e-01 1.08863230 0.97156280 831.50 6.23610230e-02 1.09140511e-01 1.25700232e-01 1.05168463 0.96131737 831.75 5.66077943e-02 9.60921566e-02 1.11526432e-01 1.03843082 0.94305366 832.00 5.32749360e-02 8.54411419e-02 1.00689660e-01 1.01325630 0.93952691 832.25 4.92994570e-02 7.58661365e-02 9.04771083e-02 0.99454650 0.93588672 832.50 4.16632336e-02 6.43870951e-02 7.66910884e-02 0.99648060 0.92949868 832.75 3.25885719e-02 6.06974291e-02 6.88926187e-02 1.07806473 0.88332733 833.00 2.26533265e-02 5.83659854e-02 6.26079983e-02 1.20056833 0.89997691 833.25 1.54243389e-02 5.47093839e-02 5.68421227e-02 1.29599676 0.88675529 833.50 7.92323366e-03 5.03384531e-02 5.09581936e-02 1.41467794 0.85315544 833.75 -9.67939905e-04 4.62108997e-02 4.62210359e-02 1.59173940 0.76132017 834.00 -8.64318094e-03 4.42486307e-02 4.50848744e-02 1.76369958 0.75164547 834.25 -1.56630155e-02 4.12695434e-02 4.41418766e-02 1.93353227 0.67200928 834.50 -2.28068066e-02 3.80217995e-02 4.43374296e-02 2.11109450 0.71637500 834.75 -3.22540320e-02 3.65801444e-02 4.87691454e-02 2.29342872 0.64306833 835.00 -4.16076144e-02 3.95944892e-02 5.74362007e-02 2.38098095 0.66317771 835.25 -5.31247088e-02 2.98747875e-02 6.09486473e-02 2.62931561 0.52497879 835.50 -7.15667486e-02 2.14687521e-02 7.47175135e-02 2.85015217 0.56581445 835.75 -7.10717106e-02 2.66841312e-02 7.59159464e-02 2.78242435 0.37574416 836.00 -6.32037226e-02 1.29581756e-02 6.45184072e-02 2.93937261 0.19753869 836.25 -2.55914974e-02 -8.77291251e-03 2.70534422e-02 -2.81134129 0.01928018 836.50 1.65790011e-02 -1.82688258e-02 2.46700886e-02 -0.83385175 0.01014358 836.75 4.46410993e-02 2.62669396e-03 4.47183102e-02 0.05877250 0.02793713 837.00 6.08504467e-02 -4.07343794e-02 7.32261328e-02 -0.58990490 0.06277518 837.25 9.01908575e-02 -6.43451686e-02 1.10791207e-01 -0.61968488 0.10882082 837.50 3.75038337e-02 -1.45056540e-01 1.49826357e-01 -1.31779039 0.14802332 837.75 -6.52425439e-02 -1.52237671e-01 1.65628796e-01 -1.97567606 0.28922718 838.00 -1.24719602e-01 -1.59587412e-01 2.02541653e-01 -2.23416248 0.47010778 838.25 -1.49460585e-01 -1.80716995e-01 2.34514602e-01 -2.26181031 0.56976776 838.50 -1.95810379e-01 -1.56002171e-01 2.50356509e-01 -2.46886702 0.57187062 838.75 -2.03635305e-01 -1.07575394e-01 2.30303719e-01 -2.65558192 0.58487288 839.00 -2.44558762e-01 -7.25398821e-02 2.55090224e-01 -2.85324393 0.66844160 839.25 -2.92656530e-01 -8.92070129e-02 3.05950545e-01 -2.84572145 0.77099419 839.50 -3.02487530e-01 -8.33714257e-02 3.13766633e-01 -2.87265070 0.73706878 839.75 -3.32478800e-01 -6.06982112e-02 3.37974001e-01 -2.96101860 0.76069557 840.00 -3.36968902e-01 2.91212443e-03 3.36981485e-01 3.13295075 0.76050788 840.25 -3.58323276e-01 9.99341661e-02 3.71997860e-01 2.86960996 0.80572685 840.50 -3.36157565e-01 1.00181263e-01 3.50768006e-01 2.85195449 0.83084970 840.75 -3.15485725e-01 1.27796815e-01 3.40386940e-01 2.75671504 0.86402487 841.00 -3.36249039e-01 1.45276690e-01 3.66290503e-01 2.73376504 0.89836257 841.25 -3.54070231e-01 1.59311974e-01 3.88260265e-01 2.71878483 0.92729007 841.50 -3.32345195e-01 1.74379445e-01 3.75315226e-01 2.65838577 0.92471256 841.75 -3.16637025e-01 1.80350117e-01 3.64396995e-01 2.62384119 0.89190451 842.00 -3.21689268e-01 2.02736761e-01 3.80244894e-01 2.57924454 0.87592806 842.25 -3.26579407e-01 2.45741455e-01 4.08708909e-01 2.49651213 0.92500929 842.50 -3.28856359e-01 2.60259951e-01 4.19382579e-01 2.47211200 0.94107769 842.75 -3.30925514e-01 2.82991422e-01 4.35426045e-01 2.43411552 0.95106361 843.00 -3.06337385e-01 3.00434046e-01 4.29072499e-01 2.36592328 0.93404740 843.25 -2.91411805e-01 3.05991726e-01 4.22553874e-01 2.33179385 0.93984930 843.50 -2.66666228e-01 3.17052774e-01 4.14286542e-01 2.27008807 0.92503702 843.75 -2.40551159e-01 3.27833702e-01 4.06619965e-01 2.20382237 0.92299236 844.00 -2.33869939e-01 3.31723329e-01 4.05876231e-01 2.18488017 0.93398366 844.25 -2.39866739e-01 3.39353771e-01 4.15568327e-01 2.18609407 0.94197817 844.50 -2.38718564e-01 3.30315160e-01 4.07547123e-01 2.19659489 0.91241519 844.75 -2.27511832e-01 3.49701586e-01 4.17196396e-01 2.14758515 0.91121129 845.00 -2.06738553e-01 3.89904799e-01 4.41323670e-01 2.05833311 0.91213220 845.25 -1.81166596e-01 4.09333265e-01 4.47632726e-01 1.98747060 0.94132225 845.50 -1.41751668e-01 4.07391177e-01 4.31348011e-01 1.90564350 0.91231861 845.75 -1.12930049e-01 3.71173827e-01 3.87973202e-01 1.86614865 0.90763904 846.00 -1.09162432e-01 3.45193070e-01 3.62042391e-01 1.87708107 0.93157178 846.25 -1.10622430e-01 3.24942279e-01 3.43256182e-01 1.89892665 0.93820705 846.50 -1.19921297e-01 3.07992683e-01 3.30515673e-01 1.94210034 0.91028132 846.75 -1.45566032e-01 2.96365178e-01 3.30184477e-01 2.02735596 0.91035887 847.00 -1.53035423e-01 2.98465247e-01 3.35412201e-01 2.04458485 0.93615659 847.25 -1.57733629e-01 2.91403337e-01 3.31354497e-01 2.06692759 0.95393720 847.50 -1.50889630e-01 2.80589520e-01 3.18587757e-01 2.06419316 0.93851174 847.75 -1.58805124e-01 2.78299417e-01 3.20421024e-01 2.08933787 0.94232240 848.00 -1.97601980e-01 2.69842790e-01 3.34457282e-01 2.20286347 0.93208875 848.25 -1.99786661e-01 2.71869054e-01 3.37383302e-01 2.20453953 0.93001103 848.50 -2.20883470e-01 2.80766147e-01 3.57238207e-01 2.23738517 0.94368017 848.75 -2.36008918e-01 2.87062321e-01 3.71624792e-01 2.25889951 0.93823168 849.00 -2.57572845e-01 2.98251497e-01 3.94078325e-01 2.28313857 0.94152914 849.25 -2.67047723e-01 3.03217139e-01 4.04048413e-01 2.29285369 0.91794120 849.50 -2.94667905e-01 3.06029163e-01 4.24832935e-01 2.33728329 0.90561183 849.75 -3.10220277e-01 3.51170975e-01 4.68569817e-01 2.29435743 0.91179101 850.00 -3.78020151e-01 4.29528898e-01 5.72183807e-01 2.29249673 0.92721399 850.25 -3.85695635e-01 4.46038005e-01 5.89670268e-01 2.28377127 0.92546795 850.50 -3.37869932e-01 4.54754273e-01 5.66531147e-01 2.20978466 0.92121981 850.75 -3.17069916e-01 4.64324971e-01 5.62255289e-01 2.16992749 0.92942667 851.00 -3.05028500e-01 4.64296446e-01 5.55529995e-01 2.15205527 0.94466669 851.25 -3.16659422e-01 4.85126755e-01 5.79328195e-01 2.14909212 0.94859366 851.50 -2.95254576e-01 4.85045280e-01 5.67841693e-01 2.11759964 0.94204478 851.75 -2.54919741e-01 4.77817653e-01 5.41566047e-01 2.06088996 0.92184556 852.00 -2.69531527e-01 4.97622379e-01 5.65928685e-01 2.06719744 0.94753657 852.25 -2.85882265e-01 4.96945369e-01 5.73309139e-01 2.09284030 0.94125195 852.50 -2.86940762e-01 5.20893681e-01 5.94697593e-01 2.07430144 0.93724383 852.75 -2.72926534e-01 4.94995620e-01 5.65251764e-01 2.07469199 0.91073290 853.00 -2.66352785e-01 4.38526521e-01 5.13078274e-01 2.11662554 0.89216303 853.25 -2.78841250e-01 4.55268770e-01 5.33874607e-01 2.12033898 0.89238683 853.50 -2.77815291e-01 4.76846107e-01 5.51872762e-01 2.09833089 0.91967850 853.75 -3.07086141e-01 4.54175760e-01 5.48249504e-01 2.16532836 0.91873726 854.00 -3.41031762e-01 4.14367793e-01 5.36659417e-01 2.25941534 0.92273218 854.25 -3.16078427e-01 3.64296811e-01 4.82304611e-01 2.28544250 0.90116626 854.50 -3.10364099e-01 3.44164162e-01 4.63438069e-01 2.30459998 0.91803637 854.75 -3.39160704e-01 2.93826997e-01 4.48736323e-01 2.42769104 0.88349780 855.00 -3.76164687e-01 2.81248801e-01 4.69681551e-01 2.49958143 0.89330601 855.25 -4.09556686e-01 2.63977950e-01 4.87258696e-01 2.56906139 0.89507351 855.50 -4.35730378e-01 2.27596625e-01 4.91590466e-01 2.66023820 0.90286406 855.75 -4.57312199e-01 1.91051233e-01 4.95615800e-01 2.74586194 0.90611747 856.00 -4.87088008e-01 1.59685723e-01 5.12595608e-01 2.82479646 0.91670850 856.25 -5.24022931e-01 1.55024686e-01 5.46472950e-01 2.85396069 0.93903830 856.50 -5.17055638e-01 1.28422799e-01 5.32765379e-01 2.89814562 0.93988416 856.75 -4.92970447e-01 1.05953798e-01 5.04228191e-01 2.92988406 0.92735164 857.00 -4.87409905e-01 8.95233962e-02 4.95563168e-01 2.95994555 0.93686090 857.25 -4.85304076e-01 8.71594255e-02 4.93068770e-01 2.96388956 0.92168491 857.50 -4.82536176e-01 8.10103293e-02 4.89289111e-01 2.97525932 0.92987046 857.75 -4.31749766e-01 4.72747832e-02 4.34330249e-01 3.03253133 0.92128335 858.00 -4.05196258e-01 1.72585240e-02 4.05563638e-01 3.09902538 0.92762439 858.25 -4.10572846e-01 -3.07852069e-03 4.10584388e-01 -3.13409468 0.88667258 858.50 -4.06013788e-01 -2.56957871e-02 4.06826092e-01 -3.07838898 0.87836935 858.75 -3.75116557e-01 -6.94810766e-02 3.81497118e-01 -2.95844305 0.88998926 859.00 -3.97385184e-01 -8.24363509e-02 4.05845705e-01 -2.93704691 0.91844842 859.25 -3.96346408e-01 -1.11330206e-01 4.11685426e-01 -2.86775776 0.90234391 859.50 -3.79166699e-01 -1.07049361e-01 3.93988517e-01 -2.86642654 0.88564329 859.75 -3.78877425e-01 -9.32285250e-02 3.90179011e-01 -2.90032081 0.86964864 860.00 -3.78201626e-01 -9.01347461e-02 3.88793958e-01 -2.90763244 0.88760872 860.25 -3.61338880e-01 -9.62975657e-02 3.73950541e-01 -2.88114392 0.91264654 860.50 -3.61663509e-01 -9.48933968e-02 3.73905403e-01 -2.88499627 0.92348229 860.75 -3.65941721e-01 -7.78359839e-02 3.74128031e-01 -2.93201544 0.93557226 861.00 -3.58518204e-01 -6.85607017e-02 3.65014893e-01 -2.95264043 0.92860462 861.25 -3.68061704e-01 -5.83539460e-02 3.72658826e-01 -2.98435745 0.92502744 861.50 -3.62300853e-01 -4.64911632e-02 3.65271593e-01 -3.01396813 0.92867981 861.75 -3.51245271e-01 -4.24475714e-02 3.53800844e-01 -3.02132706 0.93718331 862.00 -3.35015360e-01 -3.28080300e-02 3.36617971e-01 -3.04397399 0.92687897 862.25 -3.19291435e-01 -4.47126563e-02 3.22406951e-01 -3.00246030 0.93392723 862.50 -3.17891073e-01 -2.92774912e-02 3.19236442e-01 -3.04975261 0.92321625 862.75 -3.06779904e-01 -2.34829180e-02 3.07677359e-01 -3.06519517 0.94239748 863.00 -2.98953756e-01 -1.96006553e-02 2.99595618e-01 -3.07612219 0.92909036 863.25 -3.03713493e-01 -2.71984808e-02 3.04928915e-01 -3.05227782 0.94811630 863.50 -2.90045602e-01 -1.41300132e-02 2.90389581e-01 -3.09291462 0.92561658 863.75 -2.76662474e-01 -8.62718630e-03 2.76796953e-01 -3.11041968 0.88332703 864.00 -2.89941855e-01 -6.93520820e-03 2.90024786e-01 -3.11767791 0.86576567 864.25 -3.00586654e-01 5.27442468e-03 3.00632926e-01 3.12404735 0.90417303 864.50 -2.97584376e-01 -1.33729881e-03 2.97587381e-01 -3.13709884 0.90919573 864.75 -3.03682084e-01 1.05749194e-02 3.03866150e-01 3.10678438 0.91347237 865.00 -3.09693260e-01 1.28716640e-02 3.09960635e-01 3.10005394 0.89435741 865.25 -3.05306804e-01 9.91387706e-03 3.05467723e-01 3.10913221 0.87586830 865.50 -3.03213382e-01 3.19449725e-02 3.04891515e-01 3.03662512 0.86787760 865.75 -2.86851398e-01 3.29828772e-02 2.88741398e-01 3.02711295 0.84487784 866.00 -3.01879038e-01 4.83468387e-02 3.05725973e-01 2.98278820 0.78195816 866.25 -3.16679332e-01 4.36398785e-02 3.19672079e-01 3.00465053 0.81169782 866.50 -3.19058653e-01 6.37824318e-02 3.25371515e-01 2.94428539 0.79667498 866.75 -3.16802928e-01 7.43473494e-02 3.25409932e-01 2.91108385 0.75679623 867.00 -3.24219000e-01 1.03975564e-01 3.40483301e-01 2.83125897 0.74551168 867.25 -3.12706032e-01 1.37574393e-01 3.41631053e-01 2.72712935 0.70161619 867.50 -3.54317864e-01 1.54955458e-01 3.86719980e-01 2.72932106 0.73330424 867.75 -3.64793669e-01 1.73906494e-01 4.04126081e-01 2.69673730 0.78777174 868.00 -3.43323404e-01 2.46850503e-01 4.22854739e-01 2.51822663 0.82703289 868.25 -3.38670946e-01 2.69600786e-01 4.32877112e-01 2.46926168 0.82554657 868.50 -3.16853281e-01 2.75336320e-01 4.19769092e-01 2.42618752 0.70500902 868.75 -2.84154029e-01 2.69986483e-01 3.91964556e-01 2.38175563 0.70875623 869.00 -2.91793672e-01 2.45719983e-01 3.81473272e-01 2.44170180 0.71359704 869.25 -3.11268597e-01 2.90493574e-01 4.25763615e-01 2.39070443 0.74029775 869.50 -2.82231677e-01 3.33600255e-01 4.36971223e-01 2.27297384 0.75830427 869.75 -2.53646860e-01 3.72010556e-01 4.50253910e-01 2.16922127 0.71796418 870.00 -1.99632879e-01 4.53557552e-01 4.95547919e-01 1.98542798 0.72701948 870.25 -1.98743925e-01 4.43965788e-01 4.86420363e-01 1.99169923 0.71776110 870.50 -1.96852352e-01 3.88569889e-01 4.35588576e-01 2.03971581 0.74570984 870.75 -1.54673459e-01 3.84410478e-01 4.14361309e-01 1.95334014 0.72662472 871.00 -5.60051591e-02 4.57025566e-01 4.60444292e-01 1.69273113 0.71341213 871.25 -9.53565558e-03 4.46471816e-01 4.46573634e-01 1.59215088 0.69538697 871.50 -1.58196295e-02 4.22412320e-01 4.22708444e-01 1.60822951 0.73946687 871.75 2.42245521e-02 4.37680782e-01 4.38350654e-01 1.51550521 0.74635530 872.00 1.14595757e-01 4.07660862e-01 4.23461410e-01 1.29676268 0.74144060 872.25 1.51024539e-01 3.99885955e-01 4.27454312e-01 1.20968774 0.72804682 872.50 1.90287682e-01 3.91411249e-01 4.35215082e-01 1.11828357 0.67730364 872.75 1.76723259e-01 3.08823095e-01 3.55812892e-01 1.05103305 0.61650758 873.00 2.45917970e-01 2.54520428e-01 3.53915663e-01 0.80258631 0.58189975 873.25 2.68188053e-01 2.51811431e-01 3.67877464e-01 0.75391503 0.59965288 873.50 2.86521897e-01 3.02266532e-01 4.16485118e-01 0.81213253 0.70514409 873.75 3.20591539e-01 1.65796051e-01 3.60925568e-01 0.47727855 0.65418570 874.00 3.16877022e-01 1.03855947e-01 3.33462299e-01 0.31671575 0.69687643 874.25 3.26214406e-01 7.80897257e-02 3.35430834e-01 0.23496018 0.72764659 874.50 3.17368395e-01 9.77389241e-02 3.32077695e-01 0.29874965 0.79666978 874.75 2.84459040e-01 8.62758914e-02 2.97254899e-01 0.29447984 0.79013253 875.00 2.89501703e-01 4.17094436e-02 2.92490878e-01 0.14308861 0.79011488 875.25 2.48778346e-01 2.77912911e-02 2.50325830e-01 0.11124981 0.79701344 875.50 2.56004010e-01 2.07132498e-02 2.56840596e-01 0.08073400 0.87177456 875.75 2.56576378e-01 -6.08730052e-03 2.56648579e-01 -0.02372065 0.87802309 876.00 2.44919244e-01 -6.24689268e-03 2.44998898e-01 -0.02550040 0.89368815 876.25 2.40832569e-01 -1.96588595e-02 2.41633601e-01 -0.08144816 0.89173235 876.50 2.26049246e-01 -4.18690835e-02 2.29894067e-01 -0.18314551 0.88992505 876.75 1.84350966e-01 -6.22604185e-02 1.94580673e-01 -0.32570021 0.85278092 877.00 1.58928661e-01 -6.49657604e-02 1.71694115e-01 -0.38804644 0.89887982 877.25 1.43920834e-01 -8.01824783e-02 1.64749617e-01 -0.50830009 0.92683706 877.50 1.29049867e-01 -8.49358343e-02 1.54492602e-01 -0.58209225 0.93831730 877.75 1.13413466e-01 -7.67569474e-02 1.36946133e-01 -0.59497744 0.94486106 878.00 1.02852945e-01 -7.80791217e-02 1.29132016e-01 -0.64932100 0.92740688 878.25 7.83433230e-02 -7.10266615e-02 1.05747165e-01 -0.73645380 0.92115005 878.50 7.31330078e-02 -6.87228170e-02 1.00355680e-01 -0.75431893 0.94966862 878.75 6.65960569e-02 -6.71555301e-02 9.45774815e-02 -0.78958107 0.92223368 879.00 6.06605414e-02 -6.24498208e-02 8.70613657e-02 -0.79993109 0.90051369 879.25 5.20371385e-02 -5.76448132e-02 7.76581501e-02 -0.83648037 0.83025015 879.50 4.42685927e-02 -5.63325746e-02 7.16454273e-02 -0.90474715 0.80778539 879.75 2.74699200e-02 -5.35251849e-02 6.01626289e-02 -1.09663281 0.71712704 880.00 1.73317009e-02 -5.19907768e-02 5.48035467e-02 -1.24902081 0.63356466 880.25 6.06456232e-03 -4.53873904e-02 4.57907646e-02 -1.43796533 0.40051171 880.50 1.99784389e-03 -4.53771502e-02 4.54211090e-02 -1.52679721 0.36132247 880.75 -1.67825975e-02 -3.91375953e-02 4.25841161e-02 -1.97588976 0.40556127 881.00 -2.45980437e-02 -2.76631180e-02 3.70177234e-02 -2.29761242 0.34235800 881.25 -3.60554846e-02 -2.39446532e-03 3.61349060e-02 -3.07527946 0.44531465 881.50 -3.85761099e-02 4.58173744e-03 3.88472466e-02 3.02337509 0.53424273 881.75 -3.48762023e-02 1.48902254e-02 3.79218710e-02 2.73807560 0.55746474 882.00 -2.79268027e-02 1.96463433e-02 3.41450599e-02 2.52852545 0.53952092 882.25 -2.15122730e-02 2.37862810e-02 3.20712496e-02 2.30603614 0.66548862 882.50 -2.05259993e-02 2.42797455e-02 3.17934378e-02 2.27261144 0.72084185 882.75 -1.58147298e-02 2.02177017e-02 2.56682906e-02 2.23460259 0.66313625 883.00 -1.45256616e-02 1.71822920e-02 2.24994667e-02 2.27260536 0.60731037 883.25 -1.49936824e-02 1.50870513e-02 2.12703932e-02 2.35309056 0.64851416 883.50 -1.41070809e-02 1.37912547e-02 1.97283663e-02 2.36751462 0.54743900 883.75 -1.10393201e-02 1.20396452e-02 1.63346149e-02 2.31287802 0.45392857 884.00 -1.64316568e-02 1.07665729e-02 1.96448069e-02 2.56154710 0.47679586 884.25 -2.16143640e-02 9.67017246e-03 2.36789562e-02 2.72090662 0.60931278 884.50 -2.22297278e-02 1.41375170e-02 2.63444526e-02 2.57514120 0.62413671 884.75 -2.13308580e-02 1.80240019e-02 2.79261553e-02 2.44002419 0.65450115 885.00 -2.01360815e-02 1.80693608e-02 2.70548254e-02 2.41023675 0.65465056 885.25 -2.11194048e-02 1.32205218e-02 2.49160883e-02 2.58228224 0.63232405 885.50 -2.15970213e-02 1.33550255e-02 2.53926768e-02 2.58777266 0.61377257 885.75 -2.06323677e-02 1.23402773e-02 2.40411530e-02 2.60256931 0.65516155 886.00 -1.44460868e-02 1.32364587e-02 1.95931943e-02 2.39986313 0.59010650 886.25 -1.48703494e-02 1.29688363e-02 1.97311430e-02 2.42439204 0.65153384 886.50 -2.05618546e-02 9.23087227e-03 2.25388302e-02 2.71962732 0.64754459 886.75 -2.41490374e-02 6.63278310e-03 2.50433588e-02 2.87354224 0.73662885 887.00 -2.57427223e-02 7.61756207e-03 2.68461357e-02 2.85389118 0.70286232 887.25 -2.71779486e-02 9.00576014e-03 2.86311824e-02 2.82161666 0.66317494 887.50 -2.96904383e-02 7.36776131e-03 3.05909470e-02 2.89835342 0.64754194 887.75 -3.03531052e-02 5.45052580e-03 3.08385996e-02 2.96391565 0.70701493 888.00 -3.04909037e-02 1.69092048e-03 3.05377540e-02 3.08619284 0.63316528 888.25 -3.28786502e-02 8.92296615e-04 3.28907561e-02 3.11446022 0.62875838 888.50 -3.42368626e-02 1.10553964e-02 3.59775563e-02 2.82925301 0.60098392 888.75 -3.36249375e-02 1.33574572e-02 3.61809077e-02 2.76346048 0.66683027 889.00 -3.47781898e-02 1.43759552e-02 3.76323076e-02 2.74962130 0.67781814 889.25 -3.50654549e-02 1.53124161e-02 3.82629875e-02 2.72986989 0.66915700 889.50 -2.92096186e-02 1.16481763e-02 3.14464915e-02 2.76213949 0.47999287 889.75 -2.43422344e-02 9.32854396e-03 2.60684888e-02 2.77563091 0.33492904 890.00 -3.20805082e-02 1.66392057e-03 3.21236305e-02 3.08977206 0.49944016 890.25 -3.28664417e-02 -2.77328870e-03 3.29832400e-02 -3.05741151 0.46661040 890.50 -2.84094930e-02 -8.56955309e-03 2.96738358e-02 -2.84862829 0.48689279 890.75 -3.03045428e-02 -8.51669246e-03 3.14785541e-02 -2.86762276 0.53692158 891.00 -2.77608764e-02 -8.71394532e-03 2.90963761e-02 -2.83743920 0.37998863 891.25 -2.69904169e-02 -8.70639967e-03 2.83599013e-02 -2.82955679 0.36265075 891.50 -3.07671849e-02 -1.20586786e-02 3.30458983e-02 -2.76805977 0.42641500 891.75 -3.20450771e-02 -1.54378433e-02 3.55698464e-02 -2.69264812 0.44595052 892.00 -2.57420685e-02 -2.33129087e-02 3.47296099e-02 -2.40567320 0.34016515 892.25 -2.78906735e-02 -2.94577551e-02 4.05665996e-02 -2.32887566 0.36768655 892.50 -2.88259491e-02 -4.22803027e-02 5.11718608e-02 -2.16919052 0.45879286 892.75 -2.54195978e-02 -4.56307310e-02 5.22333185e-02 -2.07905280 0.46036509 893.00 -3.52353662e-02 -5.12455386e-02 6.21903229e-02 -2.17313745 0.54008971 893.25 -5.07975594e-02 -6.34148605e-02 8.12516866e-02 -2.24616840 0.54626578 893.50 -6.82355728e-02 -8.57275937e-02 1.09568763e-01 -2.24306783 0.70307570 893.75 -7.95170247e-02 -7.76002319e-02 1.11106945e-01 -2.36839364 0.65978086 894.00 -8.86277113e-02 -7.61296022e-02 1.16835729e-01 -2.43190718 0.75997419 894.25 -1.04342191e-01 -6.47238873e-02 1.22786295e-01 -2.58637730 0.72547720 894.50 -1.27625040e-01 -5.46106256e-02 1.38818123e-01 -2.73726910 0.74098939 894.75 -1.18221809e-01 -5.73428543e-02 1.31394821e-01 -2.68998076 0.68698303 895.00 -1.15568166e-01 -4.19793434e-02 1.22956359e-01 -2.79316899 0.71235795 895.25 -1.19141618e-01 -3.38048712e-02 1.23844639e-01 -2.86512211 0.70490393 895.50 -1.08836888e-01 -4.03974022e-02 1.16092284e-01 -2.78618067 0.68983106 895.75 -1.09772895e-01 -4.35148081e-02 1.18083136e-01 -2.76418702 0.71133517 896.00 -1.30994557e-01 -5.41166390e-02 1.41732793e-01 -2.74982625 0.74449305 896.25 -1.44767043e-01 -4.97784147e-02 1.53086209e-01 -2.81040550 0.73556875 896.50 -1.44596327e-01 -5.76939786e-02 1.55681383e-01 -2.76194838 0.68094583 896.75 -1.40973778e-01 -5.04586192e-02 1.49732022e-01 -2.79787157 0.58449556 897.00 -1.46608907e-01 -6.66045003e-02 1.61028976e-01 -2.71516819 0.63272394 897.25 -1.42359203e-01 -8.02940253e-02 1.63441957e-01 -2.62804615 0.59236688 897.50 -1.66293353e-01 -7.34926814e-02 1.81809388e-01 -2.72545659 0.64323143 897.75 -1.69262806e-01 -4.34227870e-02 1.74743915e-01 -2.89046764 0.57544650 898.00 -1.81764123e-01 -2.11643780e-02 1.82992151e-01 -3.02567594 0.61513717 898.25 -1.92998462e-01 -4.28676587e-02 1.97701903e-01 -2.92302685 0.69211984 898.50 -1.98995646e-01 -5.16903091e-02 2.05599502e-01 -2.88745318 0.72958626 898.75 -2.14305291e-01 -5.64260158e-02 2.21609235e-01 -2.88413852 0.77238508 899.00 -2.35158691e-01 -4.71383875e-02 2.39836689e-01 -2.94376105 0.84109695 899.25 -2.31236073e-01 -1.93789027e-02 2.32046684e-01 -3.05798232 0.77942776 899.50 -2.36787776e-01 -9.03113223e-03 2.36959938e-01 -3.10347094 0.80815039 899.75 -2.32126237e-01 -4.59249519e-03 2.32171663e-01 -3.12181076 0.81568578 900.00 -2.52270806e-01 3.07273247e-03 2.52289519e-01 3.12941296 0.80096102 900.25 -2.70616498e-01 3.28102747e-03 2.70636388e-01 3.12946898 0.76665980 900.50 -2.72701154e-01 3.49180991e-03 2.72723508e-01 3.12878882 0.76397940 900.75 -2.81554403e-01 4.54195415e-02 2.85194349e-01 2.98165343 0.84985086 901.00 -2.83026010e-01 5.58709445e-02 2.88487928e-01 2.94669286 0.88169460 901.25 -2.61251118e-01 7.40413217e-02 2.71540539e-01 2.86542416 0.84820330 901.50 -2.75393536e-01 6.82722267e-02 2.83729971e-01 2.89858401 0.82631909 901.75 -3.00878642e-01 8.81555030e-02 3.13527271e-01 2.85657612 0.85271539 902.00 -2.96190104e-01 1.17225021e-01 3.18544005e-01 2.76473270 0.84810832 902.25 -2.91247210e-01 1.52406700e-01 3.28713765e-01 2.65948726 0.87554736 902.50 -2.69568095e-01 1.63501898e-01 3.15277383e-01 2.59638345 0.87151099 902.75 -2.53954675e-01 1.74230832e-01 3.07976233e-01 2.54027660 0.86376171 903.00 -2.35256083e-01 1.86802151e-01 3.00400513e-01 2.47049798 0.85275016 903.25 -1.91292390e-01 2.10819330e-01 2.84670983e-01 2.30767163 0.84746476 903.50 -1.74637069e-01 2.27687149e-01 2.86948678e-01 2.22509179 0.86603123 903.75 -1.58011582e-01 2.26339308e-01 2.76038299e-01 2.18025820 0.86691395 904.00 -1.30655357e-01 1.99680230e-01 2.38627359e-01 2.15020453 0.84748877 904.25 -1.02757836e-01 1.73471432e-01 2.01622198e-01 2.10558051 0.84036534 904.50 -9.26726282e-02 1.54649328e-01 1.80290406e-01 2.11065950 0.80412002 904.75 -8.08353461e-02 1.24704228e-01 1.48611903e-01 2.14591679 0.76399889 905.00 -9.36096842e-02 1.00020636e-01 1.36992338e-01 2.32309734 0.78927614 905.25 -1.01709833e-01 8.64956752e-02 1.33515512e-01 2.43685709 0.84317201 905.50 -1.11760636e-01 9.34623125e-02 1.45690232e-01 2.44512247 0.83726519 905.75 -1.33724670e-01 9.18835945e-02 1.62249445e-01 2.53957000 0.89074700 906.00 -1.34896906e-01 8.69691837e-02 1.60501758e-01 2.56894628 0.86171114 906.25 -1.21446857e-01 8.34718243e-02 1.47366497e-01 2.53943330 0.81502733 906.50 -1.20652181e-01 8.07458312e-02 1.45178642e-01 2.55180739 0.80727049 906.75 -1.24008939e-01 8.33426794e-02 1.49412915e-01 2.54985865 0.82849112 907.00 -1.19308229e-01 7.01901761e-02 1.38423677e-01 2.60981339 0.79714996 907.25 -1.18280209e-01 5.35712207e-02 1.29846384e-01 2.71631487 0.80359972 907.50 -1.19067099e-01 3.54968233e-02 1.24245718e-01 2.85185736 0.60058662 907.75 -1.21071597e-01 2.65463548e-02 1.23947733e-01 2.92574675 0.55847755 908.00 -1.36412489e-01 1.90245831e-02 1.37732719e-01 3.00302279 0.65263485 908.25 -1.60856821e-01 1.05396605e-02 1.61201741e-01 3.07616418 0.74671666 908.50 -1.76151558e-01 9.34868069e-03 1.76399460e-01 3.08857059 0.83265747 908.75 -1.73494964e-01 1.47450364e-02 1.74120414e-01 3.05680813 0.85370395 909.00 -1.82757156e-01 2.95588258e-02 1.85132121e-01 2.98124297 0.78400949 909.25 -1.98081077e-01 1.99287961e-02 1.99081064e-01 3.04132078 0.77833491 909.50 -2.32748968e-01 1.26037945e-02 2.33089978e-01 3.08749361 0.83968738 909.75 -2.46214376e-01 1.34201073e-02 2.46579841e-01 3.08714075 0.87504891 910.00 -2.38280241e-01 2.39251360e-02 2.39478361e-01 3.04152050 0.87103563 910.25 -2.44041235e-01 3.97004106e-02 2.47249362e-01 2.98032625 0.88686692 910.50 -2.62082458e-01 4.03780325e-02 2.65174660e-01 2.98872843 0.90274083 910.75 -2.66255969e-01 3.60881629e-02 2.68690522e-01 3.00687426 0.91061875 911.00 -2.79918316e-01 2.36112997e-02 2.80912366e-01 3.05744118 0.91723357 911.25 -3.03024183e-01 3.49956537e-02 3.05038279e-01 3.02661403 0.92035899 911.50 -3.35151853e-01 6.45439834e-02 3.41310256e-01 2.95134052 0.93971551 911.75 -3.51069858e-01 7.62460315e-02 3.59254092e-01 2.92773190 0.93446749 912.00 -4.05707359e-01 1.28227130e-01 4.25488728e-01 2.83546946 0.94963848 912.25 -4.17641728e-01 1.34821805e-01 4.38863910e-01 2.82933656 0.96063802 912.50 -4.21940794e-01 1.92083551e-01 4.63605569e-01 2.71439122 0.96794529 912.75 -4.40590093e-01 2.27936767e-01 4.96059270e-01 2.66416609 0.95876638 913.00 -4.54406898e-01 3.04851505e-01 5.47192899e-01 2.55068031 0.95106285 913.25 -4.30477442e-01 3.65812458e-01 5.64915553e-01 2.43722452 0.93281469 913.50 -3.80427765e-01 4.78298897e-01 6.11142470e-01 2.24271178 0.93188096 913.75 -3.08681940e-01 5.16156387e-01 6.01416625e-01 2.10977308 0.90369728 914.00 -1.78833926e-01 5.92570205e-01 6.18967706e-01 1.86389786 0.93104004 914.25 -9.39179672e-02 5.92644312e-01 6.00039887e-01 1.72796210 0.92059476 914.50 1.48486823e-02 5.55620631e-01 5.55819008e-01 1.54407819 0.89742035 914.75 1.02977855e-01 4.92105089e-01 5.02764216e-01 1.36451309 0.87496669 915.00 1.63605993e-01 4.05356470e-01 4.37127886e-01 1.18718161 0.90185336 915.25 1.68954107e-01 3.43339661e-01 3.82658611e-01 1.11349650 0.86111585 915.50 1.68243987e-01 2.71415094e-01 3.19330851e-01 1.01588942 0.84291147 915.75 1.44005659e-01 2.09296603e-01 2.54052549e-01 0.96813842 0.77544282 916.00 1.17615753e-01 1.42993703e-01 1.85150383e-01 0.88247133 0.72415232 916.25 9.20466889e-02 1.15909233e-01 1.48011970e-01 0.89964656 0.63243738 916.50 8.06732099e-02 1.12791417e-01 1.38672530e-01 0.94991361 0.64192527 916.75 3.86753420e-02 9.29496172e-02 1.00674790e-01 1.17649726 0.45749540 917.00 -4.86602525e-03 1.06569278e-01 1.06680314e-01 1.61642531 0.64389001 917.25 -1.97953358e-02 1.13292907e-01 1.15009296e-01 1.74377714 0.65824065 917.50 -2.55257181e-02 1.35530825e-01 1.37913621e-01 1.75695450 0.66790143 917.75 -1.17440167e-02 2.00599426e-01 2.00942907e-01 1.62927419 0.81853378 918.00 2.24129604e-03 2.21170322e-01 2.21181679e-01 1.56066287 0.87114419 918.25 2.37695286e-02 2.43911131e-01 2.45066583e-01 1.47365148 0.83241846 918.50 4.35680171e-02 2.84744885e-01 2.88058713e-01 1.41896666 0.85353372 918.75 9.86443957e-02 3.03644546e-01 3.19265919e-01 1.25668382 0.81617403 919.00 1.44274711e-01 3.01468259e-01 3.34212962e-01 1.12443640 0.76549150 919.25 1.59264633e-01 3.49919651e-01 3.84459342e-01 1.14367099 0.82938773 919.50 1.56784538e-01 3.49628523e-01 3.83172931e-01 1.14924731 0.86474399 919.75 1.86498030e-01 3.48602353e-01 3.95354418e-01 1.07955175 0.79732690 920.00 2.44497446e-01 3.44701435e-01 4.22608662e-01 0.95385460 0.81680591 920.25 2.66993611e-01 3.61871525e-01 4.49707226e-01 0.93514046 0.88146489 920.50 2.80779266e-01 3.53660289e-01 4.51566824e-01 0.89977148 0.86004447 920.75 3.21119085e-01 3.02997003e-01 4.41502719e-01 0.75636992 0.80289340 921.00 3.18271807e-01 2.49867294e-01 4.04636390e-01 0.66557395 0.78799954 921.25 2.89935209e-01 1.90562619e-01 3.46953220e-01 0.58146152 0.75503644 921.50 3.10281500e-01 1.67374487e-01 3.52546207e-01 0.49469019 0.70836929 921.75 2.77035143e-01 1.39981151e-01 3.10391999e-01 0.46786508 0.72101408 922.00 2.49546258e-01 1.20923561e-01 2.77300996e-01 0.45123061 0.66797142 922.25 2.01445505e-01 6.19525751e-02 2.10756763e-01 0.29835990 0.48000674 922.50 1.53112409e-01 5.53443776e-02 1.62807893e-01 0.34684959 0.36722619 922.75 9.89355187e-03 9.05801529e-03 1.34137992e-02 0.74133870 0.00183543 923.00 -1.34191504e-02 5.99754846e-02 6.14583790e-02 1.79091490 0.02049033 923.25 -1.26912712e-01 5.69317169e-02 1.39097293e-01 2.71991227 0.05716298 923.50 -1.01834876e-01 4.28551007e-02 1.10484848e-01 2.74325991 0.03085227 923.75 -1.76786631e-02 1.31529203e-01 1.32711968e-01 1.70440425 0.03081498 924.00 -5.83930919e-02 3.06245750e-02 6.59364677e-02 2.65857264 0.00623340 924.25 -3.95950118e-02 -3.36217579e-02 5.19440811e-02 -2.43759735 0.00349886 924.50 -8.68306317e-02 -1.82445298e-01 2.02054066e-01 -2.01500069 0.04427443 924.75 -2.41463411e-01 -2.86917348e-01 3.75001525e-01 -2.27038079 0.10449625 925.00 6.57192051e-02 -3.11421491e-01 3.18280315e-01 -1.36281806 0.06259764 925.25 4.69383056e-01 -2.75304402e-01 5.44162629e-01 -0.53045170 0.23829129 925.50 5.35006521e-01 -2.25850233e-01 5.80723949e-01 -0.39944980 0.27436270 925.75 5.85097300e-01 3.07274299e-02 5.85903598e-01 0.05246859 0.31858671 926.00 5.38561764e-01 -2.97816508e-03 5.38569998e-01 -0.00552979 0.26822203 926.25 3.03350661e-01 2.99116356e-01 4.26019035e-01 0.77837000 0.10996052 926.50 4.36084399e-01 4.58007470e-01 6.32408449e-01 0.80991318 0.16965988 926.75 8.88614898e-01 2.14400152e-01 9.14113703e-01 0.23674976 0.26803377 927.00 1.08631122e+00 6.02513509e-02 1.08798083e+00 0.05540740 0.38602336 927.25 9.96625505e-01 -1.80160317e-01 1.01277842e+00 -0.17883899 0.36419115 927.50 1.12150493e+00 -4.20862954e-01 1.19787267e+00 -0.35900408 0.56292959 927.75 1.23149078e+00 -5.24698958e-01 1.33861068e+00 -0.40277500 0.72597895 928.00 1.05409744e+00 -7.22846761e-01 1.27813491e+00 -0.60109768 0.79490296 928.25 9.41225192e-01 -8.73642598e-01 1.28419479e+00 -0.74817706 0.80887009 928.50 8.21110632e-01 -8.37628196e-01 1.17296363e+00 -0.79535574 0.76666416 928.75 7.72026537e-01 -7.92580753e-01 1.10643989e+00 -0.79853439 0.77474190 929.00 6.13760908e-01 -7.60871892e-01 9.77562524e-01 -0.89201078 0.84332314 929.25 5.43841747e-01 -7.25286469e-01 9.06534228e-01 -0.92740386 0.82290846 929.50 4.32357208e-01 -5.74579256e-01 7.19078631e-01 -0.92571234 0.76140769 929.75 3.85915049e-01 -5.26331056e-01 6.52652132e-01 -0.93812294 0.73679537 930.00 3.04879171e-01 -4.97398460e-01 5.83400838e-01 -1.02091092 0.70620381 930.25 2.96616396e-01 -4.97912854e-01 5.79567508e-01 -1.03353020 0.69286874 930.50 3.05146340e-01 -4.51731240e-01 5.45137966e-01 -0.97670038 0.57956954 930.75 2.76154677e-01 -3.85032194e-01 4.73826124e-01 -0.94860333 0.49679663 931.00 2.98591255e-01 -2.94553628e-01 4.19426486e-01 -0.77859112 0.30942557 931.25 3.61120246e-01 -2.91000426e-01 4.63776972e-01 -0.67828388 0.31530531 931.50 3.71987192e-01 -4.28673732e-01 5.67569943e-01 -0.85607990 0.30798478 931.75 4.37550651e-02 -4.75566597e-01 4.77575224e-01 -1.47904845 0.15848626 932.00 -4.52095570e-01 -4.57292733e-01 6.43045137e-01 -2.35047954 0.26626858 932.25 -4.86599719e-01 -4.04470707e-01 6.32752589e-01 -2.44810375 0.32510584 932.50 -4.48636786e-01 -4.45279257e-01 6.32098554e-01 -2.35995045 0.60031934 932.75 -3.78102405e-01 -4.88624751e-01 6.17831349e-01 -2.22936211 0.66331254 933.00 -2.53582398e-01 -4.28971560e-01 4.98317802e-01 -2.10467591 0.51879494 933.25 -2.45787025e-01 -4.47823745e-01 5.10839866e-01 -2.07275441 0.59293205 933.50 -2.02409365e-01 -4.20308752e-01 4.66507232e-01 -2.01959400 0.61006384 933.75 -2.06544333e-01 -4.05481001e-01 4.55055385e-01 -2.04192057 0.52696989 934.00 -1.61372094e-01 -4.69949739e-01 4.96884001e-01 -1.90156290 0.51888920 934.25 -1.58070479e-01 -4.19329413e-01 4.48133276e-01 -1.93128438 0.41427922 934.50 -2.21888462e-01 -4.19103934e-01 4.74217879e-01 -2.05771402 0.36023601 934.75 -2.79887226e-01 -3.90225104e-01 4.80221294e-01 -2.19300297 0.29804713 935.00 -2.42608753e-01 -3.09457674e-01 3.93221387e-01 -2.23569261 0.21207530 935.25 -2.37047767e-01 -1.70475629e-01 2.91982164e-01 -2.51812204 0.12818433 935.50 -2.52568441e-01 6.71989146e-02 2.61355144e-01 2.88155468 0.09140861 935.75 -1.86843830e-01 2.59729359e-01 3.19953054e-01 2.19441023 0.17888036 936.00 -1.26780485e-01 3.56635991e-01 3.78500359e-01 1.91235351 0.41103687 936.25 -1.35478015e-01 3.38088983e-01 3.64223081e-01 1.95192068 0.46417144 936.50 -1.66872696e-01 3.16453026e-01 3.57755523e-01 2.05606200 0.58230026 936.75 -1.74530047e-01 3.51489911e-01 3.92435848e-01 2.03167495 0.65926999 937.00 -1.96332403e-01 3.77989596e-01 4.25937258e-01 2.04985281 0.61860361 937.25 -1.93445021e-01 4.01393217e-01 4.45575461e-01 2.01988693 0.64792395 937.50 -1.68000245e-01 3.43581054e-01 3.82455256e-01 2.02557969 0.70807601 937.75 -9.60254228e-02 3.84521559e-01 3.96330305e-01 1.81551805 0.69463016 938.00 -2.06314184e-02 4.18340390e-01 4.18848824e-01 1.62007370 0.68746859 938.25 -1.30352507e-02 4.44069549e-01 4.44260827e-01 1.60014197 0.67289306 938.50 -1.06968195e-02 4.47395326e-01 4.47523183e-01 1.59470087 0.56660975 938.75 1.56930202e-01 3.66391830e-01 3.98585075e-01 1.16612331 0.44074743 939.00 2.78181384e-01 3.08294976e-01 4.15247727e-01 0.83669975 0.46373537 939.25 2.97310586e-01 1.77039100e-01 3.46029518e-01 0.53708088 0.31016080 939.50 2.43195966e-01 2.06940143e-03 2.43204770e-01 0.00850899 0.22597307 939.75 2.86869098e-01 -1.65410181e-01 3.31141069e-01 -0.52303971 0.38635920 940.00 2.14749413e-01 -2.25195851e-01 3.11175965e-01 -0.80913856 0.34424113 940.25 3.53731853e-02 -2.34933045e-01 2.37581139e-01 -1.42135181 0.25694547 940.50 -4.56720231e-02 -2.11492311e-01 2.16367584e-01 -1.78348150 0.25211000 940.75 -1.50291316e-01 -1.34651320e-01 2.01788151e-01 -2.41102770 0.32802952 941.00 -1.92462193e-01 -8.44428548e-02 2.10172052e-01 -2.72813322 0.38893022 941.25 -2.07016934e-01 3.88172945e-02 2.10624769e-01 2.95623715 0.42916295 941.50 -1.88449633e-01 9.09459253e-02 2.09247283e-01 2.69196112 0.49011713 941.75 -1.41445319e-01 1.67802551e-01 2.19464062e-01 2.27116985 0.58878069 942.00 -1.39148878e-01 1.79590698e-01 2.27189852e-01 2.22998841 0.64008216 942.25 -1.06695838e-01 2.01660146e-01 2.28146480e-01 2.05744215 0.75864697 942.50 -5.99430516e-02 2.11880686e-01 2.20196718e-01 1.84650093 0.77856221 942.75 -7.61373430e-03 1.85703516e-01 1.85859530e-01 1.61177279 0.75623969 943.00 7.47224059e-03 1.58574377e-01 1.58750330e-01 1.52370980 0.71941668 943.25 3.14721251e-02 1.20918191e-01 1.24946803e-01 1.31616959 0.62415461 943.50 2.61182321e-02 1.09686553e-01 1.12753280e-01 1.33703256 0.55432333 943.75 8.06176873e-03 8.47355087e-02 8.51181446e-02 1.47594146 0.43877185 944.00 1.36997977e-02 8.75814467e-02 8.86464566e-02 1.41563021 0.51117316 944.25 1.19302420e-02 7.77479319e-02 7.86579404e-02 1.41853625 0.52896398 944.50 9.54582924e-03 6.87415548e-02 6.94011831e-02 1.43281327 0.49842928 944.75 1.25889651e-02 4.88072074e-02 5.04046182e-02 1.31836583 0.33582004 945.00 1.94139038e-02 4.08876355e-02 4.52625496e-02 1.12750211 0.22477751 945.25 1.58589024e-03 3.22558630e-02 3.22948254e-02 1.52166993 0.14306344 945.50 -1.45780898e-02 1.43757262e-02 2.04739396e-02 2.36318356 0.07270613 945.75 -1.34350838e-02 7.78125053e-03 1.55257637e-02 2.61662720 0.04772842 946.00 -2.11146279e-02 2.44640207e-02 3.23158757e-02 2.28284034 0.17717021 946.25 -1.92428967e-02 4.80960476e-02 5.18026917e-02 1.95138296 0.36267355 946.50 -3.18921951e-03 4.79603585e-02 4.80662783e-02 1.63719556 0.32709030 946.75 9.45809190e-03 4.04549210e-02 4.15458317e-02 1.34112816 0.24426735 947.00 9.59501611e-03 3.38559164e-02 3.51893082e-02 1.29463078 0.21805530 947.25 -1.56154076e-03 1.48258855e-02 1.49078935e-02 1.67573472 0.06681290 947.50 3.10289993e-03 3.88056033e-03 4.96857490e-03 0.89629872 0.00785912 947.75 -1.18579347e-03 4.34455759e-03 4.50347497e-03 1.83724421 0.00508119 948.00 -6.72845313e-03 -2.13836945e-03 7.06007829e-03 -2.83387758 0.01348863 948.25 2.42511496e-03 -3.69194339e-03 4.41719692e-03 -0.98960898 0.00497570 948.50 -8.01253003e-03 -2.91910621e-03 8.52770886e-03 -2.79222005 0.01971128 948.75 -1.40728456e-02 -1.56862522e-02 2.10737632e-02 -2.30203194 0.08812076 949.00 -1.56001196e-02 -2.98053262e-02 3.36410642e-02 -2.05298853 0.16002283 949.25 -2.47161779e-02 -4.98279042e-02 5.56211245e-02 -2.03126358 0.31090018 949.50 -4.05420704e-02 -3.01294769e-02 5.05118288e-02 -2.50247985 0.18752631 949.75 -4.89596509e-02 -3.10753638e-02 5.79890132e-02 -2.57603864 0.24752094 950.00 -6.06257799e-02 -3.19600723e-02 6.85341623e-02 -2.65644630 0.30679236 950.25 -6.76636435e-02 -4.19211993e-02 7.95974598e-02 -2.58692002 0.39555057 950.50 -6.88835899e-02 -3.95277347e-02 7.94190831e-02 -2.62063522 0.44071290 950.75 -7.23393590e-02 -4.54085141e-02 8.54102804e-02 -2.58104323 0.46202236 951.00 -7.85548276e-02 -4.99751813e-02 9.31041336e-02 -2.57499260 0.44737097 951.25 -9.76086751e-02 -4.19740098e-02 1.06250981e-01 -2.73547489 0.44844146 951.50 -1.09761052e-01 -2.39093270e-02 1.12334966e-01 -2.92711244 0.46799648 951.75 -9.29440081e-02 -2.33903022e-02 9.58420309e-02 -2.89505212 0.42134416 952.00 -8.89831034e-02 -9.91622502e-03 8.95339277e-02 -3.03061114 0.42397283 952.25 -9.23161139e-02 -1.69847162e-02 9.38655713e-02 -2.95964315 0.47711197 952.50 -8.57940520e-02 -3.49290021e-04 8.57947630e-02 -3.13752141 0.47926734 952.75 -7.53544547e-02 1.27800527e-03 7.53652913e-02 3.12463436 0.41070287 953.00 -5.89655085e-02 -1.88937322e-02 6.19185296e-02 -2.83150871 0.27178747 953.25 -5.93574060e-02 -2.74536884e-02 6.53988276e-02 -2.70838016 0.27430855 953.50 -6.03493943e-02 -4.53954178e-02 7.55168415e-02 -2.49667864 0.32631799 953.75 -5.39064565e-02 -5.41756347e-02 7.64258167e-02 -2.35370400 0.33580527 954.00 -6.03188949e-02 -6.50573134e-02 8.87176596e-02 -2.31841887 0.35115522 954.25 -7.92329297e-02 -5.35323636e-02 9.56220221e-02 -2.54740841 0.38823226 954.50 -9.41123106e-02 -4.92620101e-02 1.06225574e-01 -2.65937052 0.52982531 954.75 -7.77298769e-02 -3.75963596e-02 8.63447741e-02 -2.69108636 0.39538828 955.00 -4.38846042e-02 -4.34977173e-02 6.17892377e-02 -2.36062198 0.20827132 955.25 -3.15047998e-02 -4.10308858e-02 5.17308998e-02 -2.22561216 0.14448881 955.50 -1.86342726e-02 -7.79271011e-04 1.86505598e-02 -3.09979777 0.01334376 955.75 -3.05969842e-02 -8.23087281e-03 3.16847394e-02 -2.87880445 0.02773069 956.00 -1.36453067e-02 -6.47629550e-02 6.61848527e-02 -1.77845519 0.09203194 956.25 -1.69996787e-02 -5.98362102e-02 6.22041890e-02 -1.84760617 0.08197340 956.50 -3.41181825e-02 -4.61041521e-02 5.73554114e-02 -2.20788221 0.05553733 956.75 -6.11622982e-02 -8.65537693e-02 1.05982931e-01 -2.18596434 0.19161805 957.00 -1.94652379e-02 -1.23613354e-01 1.25136552e-01 -1.72698253 0.22931938 957.25 -3.13019018e-02 -1.34409882e-01 1.38006614e-01 -1.79960202 0.29206772 957.50 -7.13135568e-02 -9.42004557e-02 1.18149690e-01 -2.21878813 0.32387819 957.75 -6.60151725e-02 -1.06884135e-01 1.25627312e-01 -2.12408050 0.32250779 958.00 -1.04295518e-01 -1.59888825e-01 1.90897856e-01 -2.14878689 0.60001119 958.25 -1.19812129e-01 -1.40331137e-01 1.84520390e-01 -2.27748165 0.55765590 958.50 -1.23923522e-01 -1.17800973e-01 1.70979848e-01 -2.38151770 0.58530699 958.75 -1.44947255e-01 -1.28082604e-01 1.93429212e-01 -2.41788463 0.73430778 959.00 -1.59532248e-01 -1.52084082e-01 2.20408953e-01 -2.38009166 0.81417763 959.25 -1.71554244e-01 -1.62471933e-01 2.36279469e-01 -2.38337821 0.81171189 959.50 -1.81501576e-01 -1.48252271e-01 2.34353489e-01 -2.45668553 0.82118073 959.75 -2.17030468e-01 -1.06173871e-01 2.41609426e-01 -2.68661277 0.79869869 960.00 -2.36545665e-01 -8.07451166e-02 2.49947245e-01 -2.81264357 0.85120396 960.25 -2.16509052e-01 -9.88984245e-02 2.38027452e-01 -2.71310938 0.74949094 960.50 -2.44459221e-01 -8.37638833e-02 2.58411878e-01 -2.81148092 0.74637098 960.75 -2.25677760e-01 -6.08181857e-02 2.33729123e-01 -2.87835504 0.74935665 961.00 -2.20329901e-01 -4.89242153e-02 2.25696354e-01 -2.92308800 0.77172446 961.25 -2.22380301e-01 -2.99106093e-02 2.24382805e-01 -3.00789298 0.80464746 961.50 -2.11896933e-01 -4.73240885e-02 2.17117202e-01 -2.92186315 0.83081199 961.75 -1.99567667e-01 -4.94846247e-02 2.05611240e-01 -2.89853573 0.78852310 962.00 -1.94811077e-01 -4.39630135e-02 1.99710045e-01 -2.91964060 0.77561526 962.25 -1.86813524e-01 -2.22495679e-02 1.88133825e-01 -3.02305064 0.80788174 962.50 -1.86352166e-01 -2.13975971e-02 1.87576616e-01 -3.02726988 0.82278810 962.75 -1.80270396e-01 -2.66440265e-02 1.82228757e-01 -2.99485465 0.75650492 963.00 -1.91250516e-01 -2.86686389e-02 1.93387307e-01 -2.99279955 0.69969291 963.25 -2.15348786e-01 -2.33814965e-02 2.16614390e-01 -3.03344130 0.69403209 963.50 -2.17081463e-01 -9.88632911e-03 2.17306468e-01 -3.09608208 0.65799703 963.75 -1.93851017e-01 -2.84339722e-02 1.95925260e-01 -2.99595170 0.55645025 964.00 -1.86357002e-01 -3.33330385e-02 1.89314616e-01 -2.96459779 0.55409349 964.25 -2.06275314e-01 -2.62238743e-02 2.07935559e-01 -3.01514053 0.66028417 964.50 -2.01328911e-01 -1.49648379e-02 2.01884316e-01 -3.06739880 0.58013035 964.75 -2.09352374e-01 -1.08283232e-02 2.09632223e-01 -3.08991575 0.53884613 965.00 -2.21278557e-01 3.25666501e-03 2.21302520e-01 3.12687623 0.54643442 965.25 -2.48882117e-01 4.47156806e-02 2.52867159e-01 2.96382315 0.61221072 965.50 -2.31292503e-01 6.21989154e-02 2.39509764e-01 2.87888878 0.61360907 965.75 -2.33856456e-01 6.65549641e-02 2.43142767e-01 2.86432579 0.67251542 966.00 -2.20380163e-01 5.55216536e-02 2.27266518e-01 2.89479289 0.55842449 966.25 -2.11235950e-01 5.38730464e-02 2.17997549e-01 2.89187865 0.49813303 966.50 -2.23989845e-01 6.66392363e-02 2.33692615e-01 2.85242175 0.56478172 966.75 -2.47133605e-01 1.08381104e-01 2.69854558e-01 2.72829899 0.57460498 967.00 -2.89832973e-01 8.97995751e-02 3.03425635e-01 2.84114012 0.61244892 967.25 -3.17452810e-01 8.55810971e-02 3.28786269e-01 2.87826595 0.67752251 967.50 -3.08239454e-01 1.08771999e-01 3.26868335e-01 2.80235311 0.60047743 967.75 -2.79981162e-01 1.17085586e-01 3.03477323e-01 2.74550345 0.49296765 968.00 -3.14901965e-01 4.32400006e-02 3.17856800e-01 3.00513344 0.45072112 968.25 -3.15325748e-01 3.68179487e-02 3.17467933e-01 3.02535734 0.42860589 968.50 -3.49874541e-01 4.07942924e-02 3.52244757e-01 3.02551984 0.46525478 968.75 -3.35794666e-01 7.54602324e-02 3.44169006e-01 2.92054345 0.37967275 969.00 -3.60083782e-01 5.44049995e-02 3.64170611e-01 2.99163702 0.32226136 969.25 -3.92579755e-01 -7.90046734e-03 3.92659244e-01 -3.12147088 0.37027899 969.50 -3.96510052e-01 -1.96110644e-02 3.96994730e-01 -3.09217374 0.34423905 969.75 -3.69583219e-01 -2.45697819e-02 3.70399015e-01 -3.07521063 0.36671734 970.00 -3.95186504e-01 9.08770977e-03 3.95290980e-01 3.11860070 0.45767523 970.25 -3.69448197e-01 1.75669465e-02 3.69865608e-01 3.09407929 0.37836682 970.50 -3.63474189e-01 3.27318559e-02 3.64945010e-01 3.05178214 0.38537645 970.75 -3.64309409e-01 1.12644157e-01 3.81326699e-01 2.84171779 0.49152915 971.00 -3.46085263e-01 4.28833237e-02 3.48731973e-01 3.01831132 0.40738629 971.25 -2.92641945e-01 -2.20181431e-02 2.93469090e-01 -3.06649496 0.30796713 971.50 -3.06877473e-01 -2.76884800e-02 3.08124058e-01 -3.05160980 0.30557562 971.75 -3.52765104e-01 -8.27005465e-02 3.62329406e-01 -2.91131603 0.35839470 972.00 -4.38353187e-01 -5.55784803e-02 4.41862517e-01 -3.01547631 0.42004167 972.25 -4.18190646e-01 -1.48515047e-02 4.18454279e-01 -3.10609385 0.37652679 972.50 -4.02468366e-01 1.08658491e-01 4.16878223e-01 2.87789927 0.36865619 972.75 -3.75331588e-01 8.27045883e-02 3.84335596e-01 2.92470784 0.38320282 973.00 -2.39062049e-01 3.80119247e-02 2.42065218e-01 2.98390826 0.21242868 973.25 -2.45737615e-01 3.82653290e-03 2.45767406e-01 3.12602229 0.17438862 973.50 -3.01832020e-01 9.59315611e-02 3.16710329e-01 2.83385851 0.17994043 973.75 -2.81518748e-01 1.57735091e-01 3.22696707e-01 2.63087561 0.14133843 974.00 -2.95226783e-01 1.77736899e-01 3.44600144e-01 2.59967807 0.12199719 974.25 -3.21161484e-01 1.80129780e-01 3.68227425e-01 2.63044242 0.09921761 974.50 -3.80955394e-02 -1.92117152e-01 1.95857780e-01 -1.76655027 0.01629731 974.75 -9.17156721e-02 -1.62133462e-01 1.86276740e-01 -2.08559824 0.01005426 975.00 3.06684539e-01 -2.26345186e-01 3.81166039e-01 -0.63580209 0.02347533 975.25 3.90629064e-01 -5.31392404e-01 6.59521760e-01 -0.93689655 0.08010359 975.50 3.26721727e-01 -8.21478407e-01 8.84066660e-01 -1.19225351 0.14402573 975.75 5.49087385e-01 -8.37940453e-01 1.00181892e+00 -0.99071681 0.15721319 976.00 1.28055324e+00 -9.67988666e-01 1.60524723e+00 -0.64727561 0.31731658 976.25 7.37096543e-01 -8.69860988e-01 1.14016203e+00 -0.86782947 0.19525919 976.50 1.50188762e-01 -6.29111855e-01 6.46790840e-01 -1.33645119 0.08921721 976.75 3.54455686e-01 -7.41669119e-01 8.22016980e-01 -1.12497132 0.15108194 977.00 1.45405459e-01 -7.93155185e-01 8.06373298e-01 -1.38948427 0.18164881 977.25 2.80137623e-02 -6.61147647e-01 6.61740872e-01 -1.52845024 0.16732497 977.50 -1.67369047e-01 -5.54113095e-01 5.78838250e-01 -1.86413145 0.17741815 977.75 -3.25999522e-01 -4.67423034e-01 5.69877163e-01 -2.17980211 0.20839627 978.00 -2.99256359e-01 -6.61743274e-01 7.26263402e-01 -1.99549840 0.37494437 978.25 -3.48510764e-01 -5.96879479e-01 6.91176435e-01 -2.09928452 0.35416848 978.50 -3.42127358e-01 -5.81330376e-01 6.74534013e-01 -2.10273547 0.37993452 978.75 -2.96332964e-01 -6.38244082e-01 7.03682267e-01 -2.00547344 0.52131033 979.00 -2.38381764e-01 -6.12677145e-01 6.57418549e-01 -1.94185551 0.48818027 979.25 -2.63121277e-01 -4.59926155e-01 5.29872507e-01 -2.09044439 0.40134123 979.50 -2.69550270e-01 -5.04493081e-01 5.71988301e-01 -2.06150536 0.51672289 979.75 -1.68764367e-01 -5.55860214e-01 5.80914787e-01 -1.86556117 0.42680680 980.00 -8.19972791e-02 -4.08815812e-01 4.16957938e-01 -1.76874247 0.28849247 980.25 -6.92587082e-02 -4.46740525e-01 4.52077278e-01 -1.72460307 0.32367713 980.50 5.28421701e-02 -6.04586041e-01 6.06890910e-01 -1.48361564 0.39978905 980.75 2.89507138e-01 -6.09364630e-01 6.74640375e-01 -1.12726908 0.46574021 981.00 4.79674850e-01 -5.45691156e-01 7.26544424e-01 -0.84969259 0.41724403 981.25 4.05706762e-01 -5.79180947e-01 7.07141108e-01 -0.95974586 0.27981283 981.50 4.65205922e-01 -7.29186711e-01 8.64944975e-01 -1.00291808 0.28655167 981.75 7.71192213e-01 -1.01838858e+00 1.27743991e+00 -0.92266044 0.54786664 982.00 6.62264506e-01 -1.14929925e+00 1.32645506e+00 -1.04803568 0.48828001 982.25 4.14141397e-01 -1.63673180e+00 1.68831398e+00 -1.32296843 0.47774729 982.50 2.23741755e-01 -1.90289835e+00 1.91600692e+00 -1.45375426 0.58400958 982.75 -5.51633490e-02 -2.07438645e+00 2.07511979e+00 -1.59738267 0.61303723 983.00 -2.29917583e-01 -2.06040350e+00 2.07319191e+00 -1.68192521 0.59456176 983.25 -3.58742091e-01 -1.86029685e+00 1.89457126e+00 -1.76129916 0.54611130 983.50 -5.78383972e-01 -1.94879757e+00 2.03281578e+00 -1.85930573 0.61327091 983.75 -9.26066917e-01 -1.77017374e+00 1.99777752e+00 -2.05279219 0.68201955 984.00 -1.07182079e+00 -1.67718112e+00 1.99041110e+00 -2.13944298 0.75707959 984.25 -9.56780776e-01 -1.62847908e+00 1.88874921e+00 -2.10199646 0.78621032 984.50 -8.91607591e-01 -1.59532671e+00 1.82757528e+00 -2.08043707 0.76891974 984.75 -1.12411848e+00 -1.42260837e+00 1.81313456e+00 -2.23952150 0.72414990 985.00 -1.11991087e+00 -1.55123739e+00 1.91325319e+00 -2.19610034 0.74998577 985.25 -7.38527192e-01 -1.64497724e+00 1.80315627e+00 -1.99278415 0.64395578 985.50 -5.83677827e-01 -1.43813275e+00 1.55206496e+00 -1.95634257 0.48405970 985.75 -9.32083499e-01 -1.34269483e+00 1.63450575e+00 -2.17761139 0.58059500 986.00 -1.07539712e+00 -1.16546812e+00 1.58581049e+00 -2.31602137 0.61583444 986.25 -1.03462222e+00 -9.51931382e-01 1.40592194e+00 -2.39779575 0.53189024 986.50 -1.01501644e+00 -8.06091626e-01 1.29616437e+00 -2.47041912 0.50190503 986.75 -1.08464257e+00 -7.32041854e-01 1.30856210e+00 -2.54790118 0.49176419 987.00 -1.10047209e+00 -7.26865096e-01 1.31885241e+00 -2.55786936 0.45671711 987.25 -1.17657179e+00 -4.29785842e-01 1.25261209e+00 -2.79136497 0.46792327 987.50 -9.46637189e-01 -1.79580723e-01 9.63520215e-01 -2.95411655 0.35640194 987.75 -6.26180876e-01 -1.71379309e-01 6.49209794e-01 -2.87444495 0.19139623 988.00 -7.16084776e-01 -1.09386909e-01 7.24391401e-01 -2.99000754 0.16873438 988.25 -5.24718203e-01 2.27042893e-01 5.71732165e-01 2.73322245 0.07179952 988.50 -2.98937617e-01 5.48975863e-01 6.25090551e-01 2.06943555 0.10131448 988.75 -5.29074257e-01 6.77893137e-01 8.59917830e-01 2.23351385 0.15750412 989.00 -2.69996712e-01 1.09706101e+00 1.12979693e+00 1.81210964 0.23872566 989.25 2.38223586e-01 1.34427427e+00 1.36521932e+00 1.39540372 0.40240304 989.50 6.40422349e-01 1.53207117e+00 1.66053692e+00 1.17486043 0.52386168 989.75 6.78500352e-01 1.62511031e+00 1.76106395e+00 1.17528656 0.57743277 990.00 8.75166334e-01 1.95747013e+00 2.14420275e+00 1.15036456 0.63575585 990.25 1.10251234e+00 2.37055925e+00 2.61439948e+00 1.13546849 0.75896479 990.50 1.51880419e+00 2.15770577e+00 2.63864745e+00 0.95745922 0.71544603 990.75 2.05151124e+00 2.19385823e+00 3.00361654e+00 0.81891555 0.73456239 991.00 2.57925557e+00 2.02700644e+00 3.28044423e+00 0.66607674 0.75443244 991.25 2.51719650e+00 1.94249897e+00 3.17955665e+00 0.65723971 0.77577288 991.50 2.46975635e+00 1.78803074e+00 3.04905729e+00 0.62663306 0.69193599 991.75 2.28312441e+00 1.56130710e+00 2.76592425e+00 0.59980236 0.58733756 992.00 2.09005793e+00 1.45934164e+00 2.54912145e+00 0.60953721 0.45453244 992.25 2.23291882e+00 1.55835425e+00 2.72293856e+00 0.60931524 0.44268916 992.50 2.03198985e+00 1.38120236e+00 2.45697023e+00 0.59699130 0.45099531 992.75 2.36291544e+00 1.41830612e+00 2.75589579e+00 0.54059276 0.53606006 993.00 2.73657524e+00 1.00754159e+00 2.91615914e+00 0.35277469 0.53988139 993.25 3.07386776e+00 8.20850172e-01 3.18158105e+00 0.26095228 0.56197950 993.50 2.16294641e+00 8.59336055e-01 2.32740105e+00 0.37817561 0.42417750 993.75 1.97400740e+00 8.11179616e-01 2.13417844e+00 0.38989346 0.43801269 994.00 1.98332935e+00 2.17550647e-01 1.99522520e+00 0.10925285 0.39446908 994.25 2.11623069e+00 7.57596959e-02 2.11758633e+00 0.03578407 0.44505498 994.50 2.13217415e+00 -4.13121259e-03 2.13217815e+00 -0.00193756 0.55381811 994.75 2.02778836e+00 2.37874578e-01 2.04169291e+00 0.11677371 0.53489369 995.00 1.82918444e+00 2.67679846e-01 1.84866661e+00 0.14530697 0.44082532 995.25 1.47478826e+00 3.35845371e-01 1.51254504e+00 0.22390611 0.37320428 995.50 1.44022734e+00 6.84867695e-01 1.59477226e+00 0.44387863 0.55010322 995.75 1.57239235e+00 1.06984327e+00 1.90183657e+00 0.59744470 0.62478230 996.00 1.68422320e+00 8.73005708e-01 1.89703631e+00 0.47821428 0.57938157 996.25 1.65578384e+00 7.82626269e-01 1.83142677e+00 0.44153909 0.62637435 996.50 1.39196788e+00 8.63503010e-01 1.63805129e+00 0.55524629 0.56430680 996.75 1.50481142e+00 1.02428279e+00 1.82033311e+00 0.59763594 0.55834761 997.00 1.68594544e+00 8.69606047e-01 1.89700466e+00 0.47620541 0.54314393 997.25 1.50844585e+00 7.87309812e-01 1.70154801e+00 0.48104077 0.56143500 997.50 1.64112621e+00 8.03943074e-01 1.82746264e+00 0.45551307 0.75060842 997.75 1.95710053e+00 6.12265504e-01 2.05063686e+00 0.30319746 0.77857830 998.00 2.28203146e+00 5.73307583e-01 2.35294479e+00 0.24613301 0.83048902 998.25 2.24893841e+00 4.60328891e-01 2.29556674e+00 0.20189839 0.81016340 998.50 2.29828502e+00 1.94648136e-01 2.30651294e+00 0.08449115 0.79429294 998.75 2.35524385e+00 2.54976383e-01 2.36900539e+00 0.10783903 0.82103237 999.00 2.27838415e+00 1.09142600e-01 2.28099681e+00 0.04786692 0.86332303 999.25 2.26528365e+00 8.96478793e-02 2.26705685e+00 0.03955404 0.84877896 999.50 2.30099064e+00 1.07422451e-01 2.30349680e+00 0.04665143 0.89517638 999.75 2.17388977e+00 7.58993666e-02 2.17521434e+00 0.03489991 0.90221023 1000.00 2.20794647e+00 0.00000000e+00 2.20794647e+00 0.00000000 0.94464325