========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0043 Injection acquisition : SIG0044 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -2.05289184e-02 0.00000000e+00 2.05289184e-02 3.14159265 0.00713394 0.25 -2.09347371e-02 7.15829118e-03 2.21247452e-02 2.81212188 0.00930264 0.50 -2.45345224e-02 -1.57712010e-02 2.91663088e-02 -2.57028378 0.00859223 0.75 -2.08536232e-02 -3.98502296e-03 2.12309682e-02 -2.95277408 0.00149953 1.00 1.68165696e-02 -3.96635964e-02 4.30812940e-02 -1.16978999 0.00276757 1.25 -8.64977333e-02 -6.88448479e-02 1.10550762e-01 -2.46934750 0.01899807 1.50 -1.32599531e-01 -7.07000323e-02 1.50270190e-01 -2.65175110 0.02306989 1.75 5.36866526e-02 5.74009720e-02 7.85947088e-02 0.81882165 0.00623836 2.00 8.58229395e-02 1.46005489e-02 8.70560336e-02 0.16851075 0.00455841 2.25 4.86285458e-02 -1.40369859e-01 1.48554477e-01 -1.23730407 0.01643341 2.50 1.17653104e-01 -1.84797565e-01 2.19071661e-01 -1.00385663 0.02414750 2.75 -7.90131124e-02 1.12447521e-01 1.37431863e-01 2.18330969 0.01181332 3.00 -1.56243338e-01 4.16967827e-02 1.61711479e-01 2.88079970 0.01442841 3.25 1.55628667e-01 4.59244556e-02 1.62263174e-01 0.28694610 0.01953692 3.50 2.45030727e-01 1.47484262e-01 2.85992421e-01 0.54181619 0.04118983 3.75 -1.14410991e-01 -8.50888785e-02 1.42583282e-01 -2.50212774 0.01305859 4.00 -6.48220995e-02 -8.19013009e-02 1.04449642e-01 -2.24031194 0.00634055 4.25 5.66355196e-02 1.01140774e-01 1.15918239e-01 1.06033295 0.00733788 4.50 -3.75057090e-03 1.23592754e-01 1.23649648e-01 1.60113322 0.00858910 4.75 -2.94526711e-02 -7.76527895e-02 8.30506807e-02 -1.93331990 0.00425047 5.00 -1.05774259e-01 -8.90044341e-02 1.38238863e-01 -2.44207951 0.01212824 5.25 -4.20749970e-02 4.05912539e-02 5.84632814e-02 2.37414116 0.00179004 5.50 -4.00356794e-02 3.24537501e-02 5.15373798e-02 2.46040915 0.00144018 5.75 -9.81776189e-03 -6.80339960e-02 6.87387304e-02 -1.71411366 0.00248619 6.00 1.29603326e-02 -7.56214142e-02 7.67239761e-02 -1.40106094 0.00395692 6.25 -3.73602537e-02 1.68659913e-01 1.72748241e-01 1.78878870 0.01376024 6.50 -6.98262140e-02 7.55275631e-02 1.02859676e-01 2.31699064 0.00457909 6.75 1.50753599e-01 -1.36413610e-01 2.03310897e-01 -0.73550358 0.01840070 7.00 4.33789399e-02 2.56709411e-02 5.04056509e-02 0.53435606 0.00138604 7.25 -8.26574651e-02 -1.77433573e-01 1.95741997e-01 -2.00675282 0.01908673 7.50 -5.37363118e-02 -1.15638463e-01 1.27514099e-01 -2.00580103 0.01065654 7.75 -1.51627980e-01 9.53322123e-02 1.79106882e-01 2.58031959 0.01921030 8.00 -1.56683361e-01 3.31040091e-02 1.60142283e-01 2.93337515 0.01664035 8.25 9.77797189e-02 1.06861918e-02 9.83619242e-02 0.10885641 0.00492966 8.50 -1.95817285e-02 -5.78528719e-02 6.10769914e-02 -1.89716688 0.00202263 8.75 -1.08322484e-01 -2.04248686e-01 2.31195342e-01 -2.05842503 0.02046712 9.00 -8.32010694e-02 -1.67058013e-01 1.86630109e-01 -2.03287229 0.01743666 9.25 -1.13147863e-01 -1.24517924e-03 1.13154714e-01 -3.13058821 0.00569152 9.50 3.08578437e-02 -1.54512824e-02 3.45101238e-02 -0.46422714 0.00062228 9.75 2.74090896e-01 -2.52721482e-03 2.74102546e-01 -0.00922009 0.02566320 10.00 2.47687320e-02 -4.52369269e-02 5.15739241e-02 -1.06984877 0.00133724 10.25 -1.95286370e-01 -2.10111856e-01 2.86851457e-01 -2.31964060 0.03669539 10.50 -6.21690305e-02 -7.96064046e-02 1.01005782e-01 -2.23381619 0.00524930 10.75 -1.30660371e-01 1.23505544e-02 1.31242785e-01 3.04734857 0.00648768 11.00 3.02706207e-02 -5.55722225e-03 3.07765039e-02 -0.18156294 0.00046942 11.25 -4.26114494e-02 -6.58060000e-02 7.83974824e-02 -2.14543417 0.00255509 11.50 -7.67942644e-02 -8.58562338e-02 1.15189635e-01 -2.30053766 0.00641628 11.75 -4.76019976e-02 -5.67820506e-02 7.40955562e-02 -2.26847520 0.00214784 12.00 8.75989295e-03 -6.63842768e-02 6.69597486e-02 -1.43959699 0.00202892 12.25 3.36753396e-02 -1.15419457e-01 1.20231775e-01 -1.28691174 0.00525670 12.50 -8.48475114e-02 -5.39426977e-02 1.00543099e-01 -2.57529283 0.00540325 12.75 -2.27973110e-01 -3.48372013e-02 2.30619534e-01 -2.98995298 0.02324309 13.00 -1.27172885e-02 -9.15434515e-02 9.24225781e-02 -1.70883365 0.00411174 13.25 1.84598331e-02 -6.82950528e-02 7.07458810e-02 -1.30680926 0.00192092 13.50 -6.52143688e-02 -5.22022854e-02 8.35343791e-02 -2.46656389 0.00341945 13.75 -1.61634348e-01 -1.25199671e-01 2.04451999e-01 -2.48254141 0.01382456 14.00 -9.04296017e-02 2.35601306e-02 9.34483419e-02 2.88672297 0.00413732 14.25 -1.20485255e-01 1.63172104e-02 1.21585147e-01 3.00698252 0.00665515 14.50 2.50081856e-02 -8.32732351e-02 8.69473464e-02 -1.27905074 0.00346456 14.75 9.89775552e-02 -5.04923975e-02 1.11112729e-01 -0.47172656 0.00547635 15.00 -5.40189833e-02 -9.54915329e-02 1.09711820e-01 -2.08560875 0.00617045 15.25 -5.36853680e-03 -6.34418524e-02 6.36685937e-02 -1.65521658 0.00188096 15.50 -1.14785101e-01 -4.94689737e-02 1.24991195e-01 -2.73467596 0.00539281 15.75 -6.77327854e-02 -2.88966180e-02 7.36392881e-02 -2.73834494 0.00208552 16.00 1.61703870e-01 -2.63781710e-01 3.09400925e-01 -1.02085714 0.03266525 16.25 7.02400053e-02 -1.40912912e-01 1.57448744e-01 -1.10837832 0.00866699 16.50 1.30625733e-01 -1.15914625e-01 1.74640437e-01 -0.72579865 0.01046479 16.75 5.65311898e-02 -1.44280050e-01 1.54959698e-01 -1.19736522 0.00810162 17.00 6.34276737e-02 1.43154587e-02 6.50230893e-02 0.22197810 0.00120953 17.25 1.02128699e-01 -1.15928565e-01 1.54498231e-01 -0.84859939 0.00738691 17.50 3.74997599e-01 -2.24071975e-01 4.36842591e-01 -0.53860068 0.06513653 17.75 2.80051148e-01 -1.57375702e-01 3.21240964e-01 -0.51197416 0.03941775 18.00 -1.94778572e-01 1.58549899e-01 2.51150876e-01 2.45837280 0.01669653 18.25 -4.86902397e-02 -8.22167501e-02 9.55527783e-02 -2.10547412 0.00272343 18.50 1.85337140e-01 -1.80915431e-01 2.58998549e-01 -0.77332591 0.01805370 18.75 2.23775096e-01 -1.81999536e-01 2.88442584e-01 -0.68280699 0.03035080 19.00 -5.25192464e-02 -2.01550100e-01 2.08280374e-01 -1.82570443 0.01459909 19.25 -4.02005792e-03 -1.40578611e-01 1.40636079e-01 -1.59938505 0.00691852 19.50 1.28988160e-01 -9.34779163e-02 1.59298670e-01 -0.62711252 0.00672731 19.75 1.70815078e-01 -1.05874265e-01 2.00965547e-01 -0.55486427 0.01248867 20.00 1.36075039e-01 4.80842804e-02 1.44320872e-01 0.33967025 0.00603379 20.25 1.38911694e-02 -9.69830334e-02 9.79728195e-02 -1.42853097 0.00364633 20.50 1.23317768e-01 8.38932367e-05 1.23317797e-01 0.00068030 0.00599349 20.75 1.51223558e-01 1.10725027e-03 1.51227611e-01 0.00732181 0.00773157 21.00 8.21831530e-02 -9.81523419e-02 1.28015440e-01 -0.87372045 0.00467230 21.25 4.17549100e-02 -1.69703050e-01 1.74764406e-01 -1.32954167 0.00914401 21.50 5.73623476e-02 -4.71438684e-02 7.42494663e-02 -0.68792932 0.00134462 21.75 9.63420223e-02 2.60440288e-02 9.98001839e-02 0.26401832 0.00332476 22.00 5.87296078e-02 7.72266041e-02 9.70212101e-02 0.92061906 0.00253857 22.25 1.33964666e-01 -7.34657028e-02 1.52786587e-01 -0.50161099 0.00731299 22.50 2.41990146e-01 1.50044133e-02 2.42454868e-01 0.06192496 0.01610707 22.75 5.14141276e-02 -1.83231956e-01 1.90308598e-01 -1.29723517 0.01015580 23.00 1.82008889e-02 -2.40613663e-01 2.41301071e-01 -1.49529649 0.01436750 23.25 1.33950299e-01 -2.65752413e-02 1.36561071e-01 -0.19585305 0.00628606 23.50 9.23651225e-02 1.53657247e-01 1.79281525e-01 1.02956002 0.00920716 23.75 1.48020810e-01 -1.94232976e-01 2.44206079e-01 -0.91960958 0.01687869 24.00 2.50622500e-01 -4.84076705e-01 5.45107231e-01 -1.09306314 0.08167012 24.25 2.01477407e-01 -2.16403775e-01 2.95675057e-01 -0.82110215 0.02758290 24.50 1.98242148e-02 -9.10921204e-02 9.32243203e-02 -1.35650944 0.00259943 24.75 2.06905629e-01 -3.25218240e-02 2.09445956e-01 -0.15590632 0.01301683 25.00 2.54709703e-01 1.42382665e-01 2.91804482e-01 0.50972655 0.02489230 25.25 9.82801145e-02 -2.55404376e-01 2.73661061e-01 -1.20345994 0.02130131 25.50 1.31148376e-01 -4.39420958e-01 4.58574612e-01 -1.28075549 0.06428411 25.75 4.03771835e-02 1.83999754e-01 1.88377882e-01 1.35477879 0.00846523 26.00 1.93522824e-01 2.29786923e-01 3.00421559e-01 0.87085751 0.02066332 26.25 2.57323761e-01 -2.52095460e-01 3.60232756e-01 -0.77513527 0.02947963 26.50 1.39554543e-01 -2.61297470e-01 2.96229368e-01 -1.08025551 0.01996787 26.75 -5.60924147e-02 -2.12491929e-01 2.19770741e-01 -1.82888345 0.00966251 27.00 -1.25887143e-01 -9.01994875e-03 1.26209874e-01 -3.07006382 0.00356910 27.25 2.18982952e-01 -9.24200480e-02 2.37686766e-01 -0.39936270 0.01211061 27.50 2.45995462e-01 -6.92971115e-02 2.55569671e-01 -0.27458513 0.01636280 27.75 -4.71806672e-02 -3.85910249e-02 6.09531177e-02 -2.45600712 0.00090388 28.00 -1.71880238e-01 -8.68664330e-02 1.92583991e-01 -2.67364291 0.00951861 28.25 -5.84106443e-02 -1.98493211e-01 2.06909058e-01 -1.85698820 0.01263618 28.50 -6.01648443e-02 -2.00849912e-01 2.09667584e-01 -1.86184138 0.01229036 28.75 2.14228543e-01 -4.63646743e-01 5.10746680e-01 -1.13796592 0.05651330 29.00 1.66176208e-01 -2.77500902e-01 3.23452133e-01 -1.03123666 0.02706406 29.25 1.36984743e-01 1.10463821e-01 1.75974644e-01 0.67862823 0.00851255 29.50 6.05528174e-02 3.09424888e-02 6.80005979e-02 0.47240882 0.00125739 29.75 1.16909668e-01 -2.28508253e-01 2.56678578e-01 -1.09789503 0.01485550 30.00 1.72989874e-01 -1.48609019e-01 2.28057311e-01 -0.70973153 0.01333070 30.25 8.17087210e-02 -7.48888620e-02 1.10836171e-01 -0.74187545 0.00245525 30.50 -1.26161365e-03 -5.55384377e-02 5.55527653e-02 -1.59350847 0.00070547 30.75 -1.47476380e-01 -2.88368444e-02 1.50269246e-01 -2.94849370 0.00499242 31.00 1.97055611e-02 -1.63418536e-01 1.64602330e-01 -1.45079233 0.00581106 31.25 1.87444106e-01 -1.34452770e-01 2.30679085e-01 -0.62223946 0.01157624 31.50 1.12809035e-01 -9.90620941e-02 1.50130533e-01 -0.72060548 0.00528195 31.75 -1.09391882e-01 -9.17752997e-02 1.42791069e-01 -2.44354351 0.00459931 32.00 -7.10860455e-02 -1.44678368e-01 1.61198809e-01 -2.02749072 0.00632732 32.25 -1.36855996e-01 -5.53216072e-02 1.47614511e-01 -2.75744312 0.00485912 32.50 1.75788202e-01 1.13878891e-02 1.76156680e-01 0.06469148 0.00525843 32.75 2.85894411e-01 2.37649155e-02 2.86880437e-01 0.08293413 0.01017599 33.00 1.62822291e-01 -3.02884708e-01 3.43875334e-01 -1.07754493 0.02114629 33.25 9.73039255e-03 -2.63133213e-01 2.63313062e-01 -1.53383421 0.01256554 33.50 -1.36751224e-01 1.72993936e-02 1.37841091e-01 3.01575839 0.00380264 33.75 -2.24983447e-01 3.56831914e-02 2.27795613e-01 2.98429920 0.00838318 34.00 1.13265921e-01 -1.10598457e-01 1.58307257e-01 -0.77348319 0.00480749 34.25 9.21386074e-02 -9.08306109e-02 1.29382081e-01 -0.77824956 0.00340597 34.50 1.84632015e-02 -2.40866966e-01 2.41573561e-01 -1.49429282 0.01308171 34.75 -5.65636037e-02 -2.13681046e-01 2.21040790e-01 -1.82957148 0.01041954 35.00 1.62901379e-02 -1.35290142e-01 1.36267351e-01 -1.45096432 0.00424131 35.25 1.07315980e-02 -3.80450239e-02 3.95296223e-02 -1.29586335 0.00037730 35.50 -2.07150822e-01 -1.48506309e-01 2.54883477e-01 -2.51961459 0.01505877 35.75 -1.28943380e-01 -5.49325881e-02 1.40156999e-01 -2.73885752 0.00407333 36.00 -3.00641052e-01 1.22738522e-01 3.24730329e-01 2.75398934 0.02485301 36.25 -3.11308599e-01 -8.95882550e-02 3.23943049e-01 -2.86138462 0.03122880 36.50 -1.79843459e-01 -2.65400687e-01 3.20595063e-01 -2.16635055 0.03931190 36.75 -9.52005550e-02 -1.43659282e-01 1.72340172e-01 -2.15603589 0.00822811 37.00 8.13441723e-02 3.96898823e-02 9.05105581e-02 0.45394130 0.00146799 37.25 9.74104016e-02 -1.14366000e-01 1.50227722e-01 -0.86529143 0.00410261 37.50 -1.76360069e-01 -4.27289587e-01 4.62254545e-01 -1.96223812 0.03630886 37.75 -8.71824511e-02 -3.23735533e-01 3.35269258e-01 -1.83385697 0.02067027 38.00 -3.34373884e-01 3.13922310e-02 3.35844260e-01 3.04798342 0.02474357 38.25 -1.97740454e-01 5.64636329e-02 2.05643938e-01 2.86345028 0.00965886 38.50 -2.80792867e-01 -2.58033111e-01 3.81347244e-01 -2.39840893 0.02622784 38.75 -1.65790440e-01 -2.66226428e-01 3.13628732e-01 -2.12777043 0.01770410 39.00 4.17230936e-02 -1.82732527e-01 1.87435303e-01 -1.34631578 0.00727354 39.25 -4.28751843e-02 -2.55238802e-01 2.58814852e-01 -1.73722322 0.01275243 39.50 -2.45721533e-01 -1.88349324e-01 3.09603843e-01 -2.48760524 0.01205858 39.75 -2.66311274e-01 -1.37877724e-01 2.99886582e-01 -2.66386071 0.01426796 40.00 -3.42238138e-01 -3.25281663e-02 3.43780489e-01 -3.04683190 0.02648307 40.25 -2.99497279e-01 -5.37149075e-02 3.04276044e-01 -2.96412916 0.02149842 40.50 -2.88684850e-01 -7.83731652e-02 2.99134243e-01 -2.87649866 0.01762559 40.75 -1.86211243e-01 -7.30415060e-02 2.00024220e-01 -2.76778443 0.01015141 41.00 -3.50916365e-01 1.33405549e-01 3.75418880e-01 2.77830289 0.04218789 41.25 -4.26116487e-01 -6.79910587e-02 4.31506714e-01 -2.98336664 0.03994749 41.50 -5.00206526e-01 -2.85804802e-01 5.76099777e-01 -2.62248798 0.05496849 41.75 -4.32525413e-01 -1.90593911e-01 4.72656611e-01 -2.72653826 0.04654308 42.00 -3.93527367e-01 2.24030230e-01 4.52828149e-01 2.62406203 0.04342103 42.25 -7.54733772e-01 3.23999687e-01 8.21339676e-01 2.73609393 0.10704706 42.50 -1.19173991e+00 3.26741928e-01 1.23572015e+00 2.87399622 0.22335121 42.75 -1.91110073e+00 2.78764667e-01 1.93132487e+00 2.99674814 0.40884112 43.00 -2.62072420e+00 4.67709964e-01 2.66213222e+00 2.96498604 0.52394178 43.25 -2.46252729e+00 3.24946825e-01 2.48387421e+00 3.01039401 0.39204377 43.50 -2.42566369e+00 3.56195473e-01 2.45167689e+00 2.99579015 0.31097985 43.75 -1.52900901e+00 8.82789373e-01 1.76555533e+00 2.61798622 0.06241753 44.00 -1.02629073e+00 1.07330937e+00 1.48501369e+00 2.33380414 0.02008053 44.25 1.35396961e+00 8.73400817e-01 1.61123018e+00 0.57289941 0.05031686 44.50 1.84536426e+00 4.43240173e-01 1.89784908e+00 0.23572572 0.13591365 44.75 1.36125249e+00 3.42413184e-01 1.40365777e+00 0.24643013 0.13032495 45.00 1.30119128e+00 3.15601165e-01 1.33891854e+00 0.23795268 0.14200168 45.25 1.21310590e+00 9.71938902e-02 1.21699325e+00 0.07994909 0.12803736 45.50 1.38258115e+00 1.28977505e-01 1.38858411e+00 0.09301827 0.17789184 45.75 1.27110574e+00 2.91007729e-01 1.30399206e+00 0.22506200 0.18338348 46.00 1.17605020e+00 5.61816081e-01 1.30335389e+00 0.44566069 0.22297415 46.25 6.35876502e-01 2.72886983e-01 6.91958258e-01 0.40538125 0.09058264 46.50 5.22885920e-01 4.06288420e-01 6.62178198e-01 0.66056560 0.08201535 46.75 3.72137579e-01 3.76804357e-01 5.29592203e-01 0.79162924 0.04214045 47.00 2.22702267e-01 2.47682448e-01 3.33080914e-01 0.83845418 0.01526251 47.25 3.48704988e-01 2.58778148e-02 3.49663881e-01 0.07407541 0.01529798 47.50 3.92454951e-01 1.44364384e-02 3.92720383e-01 0.03676838 0.01740990 47.75 3.71875232e-01 -1.66535860e-01 4.07462122e-01 -0.42104559 0.01900460 48.00 5.85474036e-01 -1.52431645e-01 6.04991945e-01 -0.25470144 0.03665992 48.25 4.73343146e-01 4.42321313e-01 6.47844023e-01 0.75153208 0.04389439 48.50 4.10589090e-01 3.96055121e-01 5.70476169e-01 0.76738230 0.03090048 48.75 2.61886771e-01 2.25779881e-01 3.45776280e-01 0.71149291 0.01087480 49.00 3.38927932e-01 3.09682841e-01 4.59103044e-01 0.74033987 0.01784236 49.25 3.04780368e-01 2.41745072e-01 3.89013820e-01 0.67056730 0.01129720 49.50 3.82896376e-01 -4.84507486e-01 6.17541204e-01 -0.90201063 0.01193736 49.75 -4.37635952e-01 -1.88926365e+00 1.93928914e+00 -1.79842523 0.02099566 50.00 -2.22242284e+00 -1.99405332e+00 2.98586871e+00 -2.41030285 0.02513957 50.25 -4.81501861e-01 -1.38692476e-02 4.81701566e-01 -3.11279647 0.00146403 50.50 5.45523162e-01 5.51761304e-01 7.75909826e-01 0.79108317 0.01353399 50.75 1.23215582e-02 2.02619870e-01 2.02994168e-01 1.51005992 0.00240547 51.00 -3.86625488e-02 1.25078977e-01 1.30918078e-01 1.87058534 0.00129768 51.25 2.01577328e-01 -3.16711335e-02 2.04050190e-01 -0.15584252 0.00554580 51.50 3.11364116e-01 -1.37472618e-02 3.11667451e-01 -0.04412307 0.00984918 51.75 2.91444352e-01 4.62785914e-02 2.95095778e-01 0.15747572 0.00661748 52.00 3.86923307e-01 1.30713631e-01 4.08406291e-01 0.32579053 0.01520569 52.25 6.07418010e-01 1.88855476e-01 6.36099858e-01 0.30144039 0.04624126 52.50 3.28163912e-01 8.96186050e-02 3.40180904e-01 0.26659055 0.01502512 52.75 3.93077825e-01 5.40951007e-02 3.96782631e-01 0.13676026 0.02579738 53.00 5.66837916e-01 4.45403827e-02 5.68585147e-01 0.07841581 0.06528272 53.25 5.86589920e-01 9.03065546e-03 5.86659430e-01 0.01539396 0.09575295 53.50 4.14521465e-01 1.57136449e-01 4.43305660e-01 0.36234212 0.05143875 53.75 3.58567422e-01 1.32277740e-01 3.82188430e-01 0.35341747 0.03634285 54.00 3.97141644e-01 3.90414874e-02 3.99056040e-01 0.09799135 0.02985270 54.25 5.86622348e-01 2.87266105e-02 5.87325291e-01 0.04893043 0.06105548 54.50 3.34073917e-01 -3.09503725e-01 4.55409637e-01 -0.74723919 0.03376761 54.75 1.36048110e-01 -2.68555532e-01 3.01050099e-01 -1.10188896 0.01468415 55.00 1.08188316e-01 4.89425159e-01 5.01240160e-01 1.35324299 0.03310164 55.25 4.35411129e-01 6.33379671e-01 7.68604358e-01 0.96854907 0.07373467 55.50 5.16168974e-01 2.95560498e-01 5.94799477e-01 0.52003187 0.05184765 55.75 7.06374465e-01 1.93257213e-01 7.32334101e-01 0.26705517 0.08702118 56.00 7.92801918e-01 3.07533185e-01 8.50359655e-01 0.37003785 0.14671356 56.25 9.21732298e-01 1.76202988e-01 9.38423104e-01 0.18888615 0.18983815 56.50 1.04561626e+00 2.20361494e-01 1.06858437e+00 0.20770845 0.23215672 56.75 1.12051494e+00 1.16363285e-01 1.12654079e+00 0.10347713 0.30914321 57.00 1.29513836e+00 -6.51931121e-03 1.29515477e+00 -0.00503364 0.47470924 57.25 1.64372432e+00 -1.04793684e-01 1.64706143e+00 -0.06366764 0.58221984 57.50 2.11622702e+00 -8.06320749e-01 2.26463461e+00 -0.36403633 0.75888432 57.75 2.17802335e+00 -1.37830671e+00 2.57750172e+00 -0.56420620 0.69793705 58.00 1.21290293e+00 -2.31459607e+00 2.61313768e+00 -1.08811507 0.51310279 58.25 -2.79649724e-02 -1.71408533e+00 1.71431344e+00 -1.58710969 0.34897632 58.50 -5.59806045e-01 -7.48546818e-01 9.34721963e-01 -2.21292456 0.34884152 58.75 -4.62210463e-01 -5.92422682e-01 7.51400790e-01 -2.23334936 0.33642432 59.00 -2.87863242e-01 -2.40939951e-01 3.75389539e-01 -2.44469757 0.17295894 59.25 -3.02001696e-01 -1.84039803e-01 3.53660393e-01 -2.59429012 0.16102970 59.50 -3.54714334e-01 -2.03120519e-01 4.08754454e-01 -2.62154036 0.20255911 59.75 -3.43984033e-01 -1.86751981e-01 3.91409398e-01 -2.64420999 0.16331562 60.00 -4.31231702e-01 -1.58958922e-01 4.59596257e-01 -2.78843059 0.25230610 60.25 -4.71230001e-01 1.52267784e-02 4.71475947e-01 3.10929106 0.21572965 60.50 -2.64704779e-01 2.51831951e-01 3.65360030e-01 2.38111075 0.13381776 60.75 -1.76655517e-01 3.80530376e-01 4.19536099e-01 2.00542482 0.15108640 61.00 -2.00732136e-01 4.08271622e-01 4.54949566e-01 2.02775229 0.23223524 61.25 -1.27408119e-01 3.79854870e-01 4.00652657e-01 1.89441708 0.14012486 61.50 -1.31835245e-01 3.64840385e-01 3.87929167e-01 1.91754692 0.13430577 61.75 -1.40105191e-01 3.56190677e-01 3.82754834e-01 1.94555097 0.13080715 62.00 -1.31311052e-01 2.82022968e-01 3.11094112e-01 2.00655059 0.11117146 62.25 -1.29463502e-01 2.59391007e-01 2.89904282e-01 2.03372815 0.11706663 62.50 -1.30601658e-01 3.16839766e-01 3.42701372e-01 1.96177633 0.19407063 62.75 -6.97793386e-02 2.56026502e-01 2.65365269e-01 1.83688088 0.08788084 63.00 -1.75549804e-01 2.02711264e-01 2.68159636e-01 2.28451140 0.14596380 63.25 -1.83924070e-01 4.07698362e-01 4.47265042e-01 1.99458775 0.25895604 63.50 -7.82443516e-02 5.95252175e-01 6.00372660e-01 1.70149441 0.47540576 63.75 2.65091576e-02 6.06425976e-01 6.07005107e-01 1.52711038 0.35361347 64.00 6.00189816e-02 4.97144094e-01 5.00753960e-01 1.45065025 0.28602494 64.25 3.37910287e-01 5.11210657e-01 6.12796620e-01 0.98672701 0.32322076 64.50 4.93253784e-01 4.06103601e-01 6.38920520e-01 0.68879705 0.45504043 64.75 3.90617055e-01 3.31991123e-01 5.12640019e-01 0.70444446 0.37788918 65.00 3.01511251e-01 2.91852553e-01 4.19627152e-01 0.76912173 0.33377590 65.25 2.99007723e-01 1.89057409e-01 3.53763087e-01 0.56381918 0.19625640 65.50 2.59915877e-01 1.60891208e-01 3.05683241e-01 0.55428219 0.17699336 65.75 2.25427126e-01 9.69351285e-02 2.45385020e-01 0.40610354 0.13974671 66.00 2.04404104e-01 9.08866919e-02 2.23699416e-01 0.41838946 0.14896189 66.25 3.04969890e-01 8.07200779e-02 3.15471654e-01 0.25874869 0.26143769 66.50 3.03432083e-01 6.06789218e-02 3.09439753e-01 0.19737181 0.25143684 66.75 2.02288168e-01 1.00946400e-01 2.26076710e-01 0.46286551 0.11287043 67.00 1.76176061e-01 1.57083176e-01 2.36036287e-01 0.72816933 0.15825629 67.25 1.34828092e-01 1.41229813e-01 1.95254896e-01 0.80858379 0.12331876 67.50 1.45817134e-01 1.22148570e-01 1.90218058e-01 0.69729995 0.12829086 67.75 2.25729948e-01 1.93959590e-01 2.97614402e-01 0.70984260 0.26453569 68.00 2.19454456e-01 1.88906102e-01 2.89561347e-01 0.71072993 0.21587205 68.25 2.51100054e-01 1.39628548e-01 2.87310579e-01 0.50748953 0.14986073 68.50 3.66631911e-01 1.39917975e-01 3.92423238e-01 0.36457113 0.18971489 68.75 4.40582672e-01 7.54172167e-02 4.46990880e-01 0.16953299 0.16317275 69.00 4.32339299e-01 5.04328291e-02 4.35270881e-01 0.11612621 0.15044838 69.25 2.05139677e-01 -1.04084305e-01 2.30034410e-01 -0.46953624 0.03727952 69.50 2.64782223e-01 -1.93605678e-02 2.65489091e-01 -0.07298895 0.03870066 69.75 3.48642334e-01 2.21529655e-02 3.49345432e-01 0.06345536 0.08139906 70.00 4.79104317e-01 -1.19832417e-01 4.93863093e-01 -0.24508933 0.09659148 70.25 6.20508651e-01 -3.15320546e-01 6.96030195e-01 -0.47015795 0.12158336 70.50 4.53824155e-01 -3.36024446e-01 5.64684683e-01 -0.63734731 0.07734505 70.75 3.20141884e-01 -4.28440865e-01 5.34838667e-01 -0.92907335 0.08095755 71.00 3.39169345e-01 -4.22514775e-01 5.41806773e-01 -0.89438712 0.04858590 71.25 6.50260256e-01 -3.24726184e-01 7.26832508e-01 -0.46315052 0.06874760 71.50 4.42799304e-01 1.07218358e-01 4.55595215e-01 0.23756517 0.03720755 71.75 4.53412678e-02 8.06287069e-02 9.25030753e-02 1.05852351 0.00262533 72.00 8.69339650e-02 -1.94363196e-03 8.69556897e-02 -0.02235384 0.00177069 72.25 -9.43189937e-02 -8.37175277e-03 9.46898031e-02 -3.05306466 0.00253700 72.50 -2.64470369e-02 8.11118634e-02 8.53145952e-02 1.88598335 0.00219971 72.75 -6.44460447e-02 1.94127770e-01 2.04545555e-01 1.89132610 0.02549285 73.00 -3.66311919e-02 9.30850042e-02 1.00033306e-01 1.94570759 0.00549062 73.25 -7.25579290e-02 8.19072666e-02 1.09423276e-01 2.29574110 0.00982550 73.50 -1.75070337e-01 2.18075484e-02 1.76423331e-01 3.01766649 0.01823837 73.75 -9.91671941e-02 -3.74052473e-03 9.92377142e-02 -3.10389115 0.00562195 74.00 6.21807443e-02 8.72077579e-02 1.07105733e-01 0.95138645 0.00526349 74.25 -4.72397967e-02 4.83610769e-02 6.76046756e-02 2.34446626 0.00243916 74.50 -1.44872883e-01 -4.09032199e-02 1.50536459e-01 -2.86641660 0.01257547 74.75 -1.47852310e-01 3.27566703e-02 1.51437462e-01 2.92356444 0.01641559 75.00 -1.74628254e-01 -5.45777858e-02 1.82958361e-01 -2.83867410 0.01392287 75.25 -4.61085004e-01 -2.46239799e-01 5.22717341e-01 -2.65108200 0.09939643 75.50 -2.00211467e-01 -9.35895822e-02 2.21005976e-01 -2.70431944 0.02192645 75.75 -2.01146380e-01 -1.27389988e-01 2.38092577e-01 -2.57703291 0.03694828 76.00 -4.78615516e-01 5.45367720e-02 4.81712644e-01 3.02813507 0.12946730 76.25 -5.21039020e-01 -1.07003995e-02 5.21148884e-01 -3.12105888 0.14292816 76.50 -5.33660677e-01 -9.23845841e-03 5.33740637e-01 -3.12428290 0.11295574 76.75 -4.80468425e-01 -1.80599944e-02 4.80807727e-01 -3.10402203 0.08943778 77.00 -2.00605435e-01 1.99958541e-01 2.83241873e-01 2.35780945 0.03359699 77.25 -2.11728021e-01 4.49837362e-01 4.97174423e-01 2.01071143 0.10274531 77.50 -5.81527501e-01 2.92575442e-01 6.50979741e-01 2.67545583 0.16452243 77.75 -4.93664125e-01 3.79257931e-01 6.22527788e-01 2.48651290 0.14946973 78.00 -4.22783923e-01 5.25344973e-01 6.74339370e-01 2.24844141 0.15116239 78.25 -3.43393980e-01 7.05106139e-01 7.84279346e-01 2.02399831 0.18494068 78.50 -5.26796406e-01 6.62209140e-01 8.46188749e-01 2.24279569 0.13361095 78.75 -4.40594788e-01 5.78418594e-01 7.27111984e-01 2.22175808 0.08645331 79.00 -5.02247034e-02 5.38204271e-01 5.40542652e-01 1.66384588 0.05163389 79.25 2.65230583e-02 3.24724138e-01 3.25805522e-01 1.48929850 0.02313705 79.50 -1.00819437e-02 3.23084494e-01 3.23241761e-01 1.60199149 0.02123901 79.75 -6.00686934e-02 3.22954198e-01 3.28493017e-01 1.75469247 0.02007670 80.00 -2.18724468e-01 1.81689666e-01 2.84344030e-01 2.44842334 0.02149437 80.25 -5.38635694e-01 5.92966422e-02 5.41889752e-01 3.03194743 0.06235172 80.50 -1.32520553e+00 1.11824818e+00 1.73396906e+00 2.44069152 0.30179559 80.75 -1.83671727e-01 2.26246927e+00 2.26991245e+00 1.65180066 0.35182671 81.00 1.44442992e+00 1.57475718e+00 2.13687575e+00 0.82853773 0.44606510 81.25 1.38476897e+00 1.16586430e+00 1.81020017e+00 0.69978430 0.47766631 81.50 1.29731841e+00 1.08531072e+00 1.69142969e+00 0.69665132 0.65897886 81.75 1.33405758e+00 9.60467971e-01 1.64383951e+00 0.62399665 0.72766282 82.00 1.26277746e+00 8.54066611e-01 1.52447916e+00 0.59466950 0.75138804 82.25 1.30586993e+00 8.64199126e-01 1.56592988e+00 0.58461217 0.63797017 82.50 1.76126511e+00 9.93899279e-01 2.02234778e+00 0.51376325 0.74507841 82.75 2.13208171e+00 5.53386422e-01 2.20272762e+00 0.25394853 0.66699662 83.00 2.27492875e+00 -5.72018460e-02 2.27564780e+00 -0.02513916 0.61916263 83.25 2.08771646e+00 -4.16904630e-01 2.12893623e+00 -0.19710139 0.26249256 83.50 1.39733495e+00 -3.09243630e+00 3.39348010e+00 -1.14640028 0.35724336 83.75 -1.16816688e+00 -3.40656451e+00 3.60129083e+00 -1.90114672 0.58185600 84.00 -2.11578690e+00 -2.23521681e+00 3.07778303e+00 -2.32875256 0.64626271 84.25 -1.53490351e+00 -9.09308914e-01 1.78403237e+00 -2.60676466 0.46976474 84.50 -9.87078586e-01 -5.74997429e-01 1.14234241e+00 -2.61412192 0.45051391 84.75 -8.00226573e-01 -2.86045801e-01 8.49814549e-01 -2.79829101 0.28208865 85.00 -6.96031140e-01 -3.22878597e-01 7.67274355e-01 -2.70725192 0.26474278 85.25 -4.77055389e-01 -2.95103204e-01 5.60952534e-01 -2.58761377 0.15992941 85.50 -5.25524541e-01 -1.64511509e-01 5.50672389e-01 -2.83821364 0.23342995 85.75 -5.02165405e-01 6.28718089e-02 5.06085920e-01 3.01703937 0.18585750 86.00 -5.88748611e-01 1.01247571e-01 5.97390992e-01 2.97128768 0.28393238 86.25 -4.86050072e-01 2.57606069e-01 5.50095955e-01 2.65423483 0.29343588 86.50 -4.40879176e-01 3.65513586e-01 5.72690693e-01 2.44938394 0.37268765 86.75 -3.56080702e-01 3.49725529e-01 4.99100603e-01 2.36519838 0.28976998 87.00 -3.25363729e-01 3.35919165e-01 4.67657184e-01 2.34023379 0.30836614 87.25 -1.48092469e-01 2.80226168e-01 3.16951234e-01 2.05696343 0.18822191 87.50 -1.51185726e-01 2.72015498e-01 3.11206611e-01 2.07808023 0.20059643 87.75 -1.73832066e-01 3.17568206e-01 3.62031977e-01 2.07162963 0.16197167 88.00 -7.44580401e-02 3.70948045e-01 3.78346999e-01 1.76888759 0.17600657 88.25 3.74298576e-03 2.74302396e-01 2.74327933e-01 1.55715170 0.12978251 88.50 1.11336949e-02 2.15491166e-01 2.15778594e-01 1.51917563 0.13001467 88.75 1.55859123e-02 1.07247611e-01 1.08374216e-01 1.42648021 0.03412934 89.00 -2.19858340e-02 1.80901238e-01 1.82232365e-01 1.69173820 0.05801623 89.25 -1.11584804e-01 3.93677248e-01 4.09185708e-01 1.84699426 0.22535046 89.50 -3.54647845e-02 3.88144348e-01 3.89761190e-01 1.66191342 0.19510166 89.75 -8.16338542e-02 1.96463219e-01 2.12748402e-01 1.96460765 0.08035177 90.00 2.29225442e-03 1.76321598e-01 1.76336497e-01 1.55779664 0.05191048 90.25 1.20354071e-01 1.19459838e-01 1.69575220e-01 0.78166932 0.08288000 90.50 1.05621415e-01 1.50413728e-01 1.83793833e-01 0.95859139 0.08668434 90.75 4.46938376e-03 2.58163678e-01 2.58202362e-01 1.55348585 0.16344239 91.00 3.25932186e-02 2.57848492e-01 2.59900293e-01 1.44505865 0.15108685 91.25 1.61916258e-01 2.87368425e-01 3.29844640e-01 1.05768941 0.18846376 91.50 1.66713692e-01 1.74567949e-01 2.41386462e-01 0.80840810 0.09888877 91.75 1.98471568e-01 1.63314310e-01 2.57026316e-01 0.68852536 0.18523734 92.00 1.81833093e-01 1.44173406e-01 2.32054400e-01 0.67038972 0.12276359 92.25 1.44566209e-01 1.21019557e-01 1.88534140e-01 0.69697006 0.09777387 92.50 1.68899079e-01 1.23672738e-01 2.09336678e-01 0.63203007 0.11802589 92.75 2.04363408e-01 1.50579025e-01 2.53847287e-01 0.63501234 0.20842120 93.00 1.88152291e-01 1.63740810e-01 2.49424012e-01 0.71613726 0.15493118 93.25 2.69206132e-01 1.40293424e-01 3.03569080e-01 0.48041430 0.30765659 93.50 2.58645678e-01 1.24112770e-01 2.86882495e-01 0.44740322 0.27351759 93.75 2.58110136e-01 7.67340692e-02 2.69274878e-01 0.28897051 0.30076135 94.00 2.91546256e-01 8.21087445e-02 3.02887876e-01 0.27452138 0.31750743 94.25 3.44212070e-01 9.48777743e-02 3.57048654e-01 0.26895885 0.45532033 94.50 3.21930706e-01 8.09180426e-02 3.31944437e-01 0.24625107 0.34335291 94.75 3.01050379e-01 3.99619308e-02 3.03691104e-01 0.13197016 0.29807921 95.00 2.70372182e-01 -3.79132961e-02 2.73017463e-01 -0.13931790 0.19657905 95.25 2.08479668e-01 -7.35186464e-02 2.21062804e-01 -0.33902638 0.17827770 95.50 1.65747683e-01 -7.85357689e-02 1.83412544e-01 -0.44249104 0.10856984 95.75 1.19587688e-01 -8.97099138e-02 1.49496099e-01 -0.64360357 0.10457030 96.00 4.05170664e-02 -5.35219702e-02 6.71284884e-02 -0.92281915 0.02116671 96.25 3.70522481e-02 2.04800657e-02 4.23355900e-02 0.50494041 0.01081317 96.50 1.06478397e-01 9.75938912e-02 1.44437588e-01 0.74188957 0.09650706 96.75 1.73423655e-01 6.88944844e-02 1.86607112e-01 0.37814309 0.18593793 97.00 1.34557247e-01 1.32258509e-02 1.35205680e-01 0.09797691 0.08821127 97.25 1.12804965e-01 -2.69462307e-02 1.15978703e-01 -0.23448052 0.07581828 97.50 3.38975512e-02 -5.04778176e-02 6.08034049e-02 -0.97943186 0.01253291 97.75 -1.39728644e-02 -3.72716105e-02 3.98046968e-02 -1.92947315 0.00436822 98.00 1.35246580e-01 1.61778377e-01 2.10864603e-01 0.87448686 0.08833298 98.25 1.25430956e-01 2.13435976e-01 2.47563811e-01 1.03948873 0.13786824 98.50 2.47553371e-02 3.11188680e-01 3.12171781e-01 1.49141261 0.23385531 98.75 1.28434973e-01 3.81748303e-01 4.02774514e-01 1.24625339 0.29219200 99.00 4.42851757e-01 3.85217656e-01 5.86950016e-01 0.71590966 0.34097061 99.25 4.30418378e-01 2.44994177e-01 4.95259656e-01 0.51746457 0.29869982 99.50 4.14523527e-01 1.98091738e-01 4.59423651e-01 0.44579403 0.27438103 99.75 2.34084576e-01 7.44390986e-02 2.45635438e-01 0.30788846 0.01874594 100.00 -9.51700556e-01 1.12903880e+00 1.47663894e+00 2.27117148 0.16232278 100.25 -2.78375296e-01 6.40701342e-01 6.98563537e-01 1.98067357 0.05743988 100.50 5.83137119e-01 -3.70567158e-02 5.84313358e-01 -0.06346184 0.26095391 100.75 6.02532430e-01 2.24036959e-02 6.02948799e-01 0.03716543 0.30629556 101.00 6.06281351e-01 2.80986860e-01 6.68229521e-01 0.43399031 0.38962518 101.25 6.69018976e-01 3.54334869e-01 7.57059832e-01 0.48707242 0.45225901 101.50 8.90312838e-01 2.40829069e-01 9.22309920e-01 0.26417722 0.54230348 101.75 1.17520861e+00 6.86183093e-02 1.17721015e+00 0.05832198 0.54525365 102.00 1.49134259e+00 -1.37034494e-01 1.49762518e+00 -0.09162936 0.64684589 102.25 1.30933440e+00 -3.34032530e-01 1.35127136e+00 -0.24978817 0.51333724 102.50 1.39527563e+00 -9.04906079e-01 1.66302408e+00 -0.57535525 0.61164228 102.75 1.37721330e+00 -1.10537506e+00 1.76594748e+00 -0.67633475 0.61568322 103.00 1.07165204e+00 -1.31388292e+00 1.69550182e+00 -0.88659285 0.65639267 103.25 1.15666722e+00 -1.43691020e+00 1.84461107e+00 -0.89303324 0.68890666 103.50 1.15653057e+00 -1.62127069e+00 1.99150235e+00 -0.95116788 0.75823523 103.75 1.12363307e+00 -1.76562270e+00 2.09283894e+00 -1.00404494 0.70401366 104.00 8.40625869e-01 -1.95632677e+00 2.12928774e+00 -1.16495482 0.68281819 104.25 4.45683451e-01 -2.13957578e+00 2.18550183e+00 -1.36542849 0.71120436 104.50 5.94161046e-02 -2.06610544e+00 2.06695960e+00 -1.54204671 0.74969032 104.75 -3.06911960e-02 -1.93271556e+00 1.93295923e+00 -1.58667482 0.74642029 105.00 -1.10853798e-01 -1.84656957e+00 1.84989398e+00 -1.63075666 0.76099289 105.25 -4.11434616e-01 -1.53861714e+00 1.59267735e+00 -1.83208833 0.69933443 105.50 -4.79717870e-01 -1.30032297e+00 1.38599028e+00 -1.92422780 0.74742313 105.75 -2.32876925e-01 -1.20869973e+00 1.23092920e+00 -1.76113138 0.64737877 106.00 -1.54483133e-02 -1.31532692e+00 1.31541764e+00 -1.58254063 0.57019602 106.25 -9.88959961e-01 -1.57899604e+00 1.86313453e+00 -2.13034573 0.54484610 106.50 -1.48174294e+00 -1.00574538e+00 1.79083386e+00 -2.54526554 0.63713655 106.75 -1.07761336e+00 -3.43563870e-01 1.13105557e+00 -2.83296116 0.71590012 107.00 -9.43850866e-01 -1.83759832e-01 9.61572740e-01 -2.94930650 0.80994508 107.25 -7.28593336e-01 -8.93608613e-02 7.34052868e-01 -3.01955367 0.65998827 107.50 -5.97241160e-01 -4.86618386e-02 5.99220309e-01 -3.06029453 0.60517454 107.75 -4.75274478e-01 -7.57940442e-02 4.81280134e-01 -2.98345005 0.53919061 108.00 -4.36212854e-01 -6.50486276e-02 4.41036255e-01 -2.99356218 0.50322320 108.25 -4.70689329e-01 1.60129802e-04 4.70689357e-01 3.14125245 0.41854427 108.50 -4.96883053e-01 1.00978674e-01 5.07039900e-01 2.94109881 0.46922150 108.75 -4.12509003e-01 1.44653959e-01 4.37136644e-01 2.80432231 0.34759612 109.00 -3.49598465e-01 1.80175661e-01 3.93296778e-01 2.66571778 0.27149695 109.25 -3.61328844e-01 3.37726858e-01 4.94588682e-01 2.38994434 0.19905383 109.50 -2.32305939e-01 2.60745318e-01 3.49219372e-01 2.29857796 0.08003871 109.75 5.36787848e-02 2.45587025e-01 2.51384961e-01 1.35560719 0.11887973 110.00 1.73593130e-01 3.04506733e-01 3.50512375e-01 1.05266759 0.24969975 110.25 4.63150148e-01 2.56746863e-01 5.29553597e-01 0.50617611 0.45116931 110.50 5.52870340e-01 1.84403885e-01 5.82812496e-01 0.32193575 0.47683534 110.75 4.24422128e-01 2.42628737e-01 4.88879174e-01 0.51932692 0.30713335 111.00 3.56665284e-01 2.91927452e-01 4.60903202e-01 0.68591490 0.21759476 111.25 4.60877324e-01 2.20881396e-01 5.11073868e-01 0.44692072 0.09873621 111.50 7.46315807e-01 -2.51428908e-01 7.87530177e-01 -0.32495123 0.11302832 111.75 7.06654585e-01 -1.76702122e+00 1.90308295e+00 -1.19036504 0.37757368 112.00 -3.72627368e-01 -1.82764428e+00 1.86524389e+00 -1.77192367 0.35767040 112.25 -1.75376111e+00 -3.55084785e-01 1.78934716e+00 -2.94182280 0.46520619 112.50 -1.12690010e+00 4.51171460e-01 1.21386141e+00 2.76077158 0.27058645 112.75 -1.12953936e-03 6.23839225e-01 6.23840248e-01 1.57260695 0.13258163 113.00 3.43485099e-01 3.27498144e-01 4.74591453e-01 0.76157651 0.06512389 113.25 5.96959210e-01 3.13018247e-01 6.74048011e-01 0.48294084 0.14931009 113.50 8.89656376e-01 3.41396175e-01 9.52911232e-01 0.36641048 0.21965103 113.75 8.89325788e-01 3.09462412e-01 9.41630151e-01 0.33486894 0.20388849 114.00 9.81819496e-01 5.37624175e-01 1.11937897e+00 0.50098292 0.17318169 114.25 1.49231330e+00 8.03622661e-01 1.69493610e+00 0.49397739 0.23555640 114.50 1.36332142e+00 1.03918217e+00 1.71421844e+00 0.65129068 0.18384791 114.75 2.02190951e+00 1.50219391e+00 2.51886971e+00 0.63897899 0.27124743 115.00 2.68942053e+00 2.59890086e+00 3.73995568e+00 0.76828293 0.33619428 115.25 3.78460783e+00 3.60043085e+00 5.22363463e+00 0.76046413 0.53001763 115.50 3.72115955e+00 3.76081937e+00 5.29063236e+00 0.79069883 0.68262979 115.75 4.20150891e+00 4.18184248e+00 5.92794092e+00 0.78305228 0.83177918 116.00 4.50517961e+00 3.59657796e+00 5.76472171e+00 0.67371612 0.88750975 116.25 4.62357300e+00 3.05044516e+00 5.53919154e+00 0.58320530 0.93041819 116.50 4.33876310e+00 2.51671229e+00 5.01584549e+00 0.52562341 0.90340274 116.75 3.60459471e+00 1.98095188e+00 4.11306132e+00 0.50250764 0.85414684 117.00 2.37819694e+00 1.41330017e+00 2.76644863e+00 0.53619843 0.56161449 117.25 1.18990546e+00 1.47374726e+00 1.89415047e+00 0.89155866 0.42222109 117.50 4.65667173e-02 1.93501592e+00 1.93557616e+00 1.54673568 0.38415459 117.75 -8.11092112e-01 2.35868261e+00 2.49424419e+00 1.90200424 0.47300517 118.00 -1.36061946e+00 3.21920403e+00 3.49493346e+00 1.97068085 0.48658055 118.25 -2.27108731e+00 3.14370315e+00 3.87823504e+00 2.19641411 0.36987000 118.50 -5.25626094e+00 5.10388782e+00 7.32652373e+00 2.37090105 0.42796737 118.75 -7.83880286e+00 8.26071100e+00 1.13879839e+01 2.32999422 0.59234789 119.00 -6.80964139e+00 1.33299866e+01 1.49686258e+01 2.04308727 0.61316694 119.25 -4.60882422e+00 1.77899227e+01 1.83772308e+01 1.82429249 0.63545099 119.50 7.19005509e+00 2.60861702e+01 2.70589203e+01 1.30184721 0.73157570 119.75 1.36682649e+01 2.50448256e+01 2.85318200e+01 1.07122035 0.70832380 120.00 2.22353932e+01 1.45551605e+01 2.65756544e+01 0.57959814 0.70474328 120.25 2.04926069e+01 7.85515882e+00 2.19465363e+01 0.36604203 0.72140705 120.50 1.69332192e+01 2.04003871e+00 1.70556639e+01 0.11989769 0.81687301 120.75 1.48279824e+01 2.19707882e-01 1.48296100e+01 0.01481603 0.85266028 121.00 9.22070730e+00 -2.98008853e-01 9.22552179e+00 -0.03230828 0.82715974 121.25 7.54255738e+00 8.22220446e-02 7.54300553e+00 0.01090065 0.85387007 121.50 6.20299246e+00 4.64839385e-01 6.22038513e+00 0.07479812 0.88858228 121.75 5.43510999e+00 8.12179852e-01 5.49545783e+00 0.14833449 0.85822355 122.00 4.47790775e+00 1.82753933e+00 4.83648196e+00 0.38748971 0.84319597 122.25 4.99007700e+00 2.02254456e+00 5.38438065e+00 0.38507840 0.68671445 122.50 8.74397286e+00 -1.04156163e+00 8.80578855e+00 -0.11855903 0.47070390 122.75 5.18478894e+00 -6.63308206e+00 8.41901502e+00 -0.90734121 0.29594399 123.00 -7.11016158e+00 -8.02067150e-01 7.15525746e+00 -3.02926177 0.18642229 123.25 -4.57087663e+00 5.02144199e+00 6.79027193e+00 2.30925751 0.23385287 123.50 -3.53209058e+00 2.89260180e+00 4.56539254e+00 2.45540381 0.19431487 123.75 -2.94876873e+00 4.58634267e-02 2.94912538e+00 3.12604049 0.06546988 124.00 2.43517500e+00 -3.50467879e+00 4.26765166e+00 -0.96354493 0.06435270 124.25 1.06172277e+01 -4.17070770e-01 1.06254163e+01 -0.03926227 0.26295150 124.50 1.56722820e+01 3.68661133e+00 1.61000474e+01 0.23103115 0.63714214 124.75 1.20953486e+01 5.22785178e+00 1.31767937e+01 0.40797014 0.64910146 125.00 8.61647371e+00 5.18365018e+00 1.00555382e+01 0.54159340 0.65417155 125.25 6.47999000e+00 3.95380321e+00 7.59097031e+00 0.54785352 0.62499853 125.50 5.22527462e+00 3.23577657e+00 6.14603489e+00 0.55445729 0.63119309 125.75 2.72118218e+00 3.10868427e+00 4.13143442e+00 0.85176897 0.41570403 126.00 1.24224908e+00 1.91140938e+00 2.27962027e+00 0.99448253 0.19619401 126.25 1.37901515e+00 1.23777718e+00 1.85304482e+00 0.73147678 0.11707946 126.50 1.27905803e+00 1.53053943e+00 1.99462789e+00 0.87466825 0.12138669 126.75 -1.97082725e+00 2.15204580e+00 2.91812632e+00 2.31226833 0.15564087 127.00 -4.20185452e+00 3.60088988e+00 5.53371388e+00 2.43306238 0.43396332 127.25 -5.05650168e+00 3.28024408e+00 6.02728882e+00 2.56611913 0.45141401 127.50 -6.40045353e+00 2.78638824e+00 6.98067080e+00 2.73099469 0.52172958 127.75 -5.66272088e+00 2.65310981e+00 6.25343101e+00 2.70344297 0.55852474 128.00 -4.94590284e+00 2.19517657e+00 5.41116947e+00 2.72387537 0.51783680 128.25 -4.98790195e+00 1.92269017e-01 4.99160627e+00 3.10306466 0.27597928 128.50 -5.48413663e+00 -5.61347059e-01 5.51279105e+00 -3.03958957 0.31889877 128.75 -6.91716548e+00 -5.69377480e+00 8.95914336e+00 -2.45290214 0.37295970 129.00 -1.03696351e+01 -1.00875247e+01 1.44667718e+01 -2.36998392 0.55131036 129.25 -2.23909135e+01 -1.22038929e+01 2.55007453e+01 -2.64256722 0.72581874 129.50 -2.92543211e+01 -7.22139867e+00 3.01324393e+01 -2.89958187 0.73007871 129.75 -3.57363811e+01 3.84482932e+00 3.59426160e+01 3.03441626 0.82793455 130.00 -3.73540381e+01 8.87430633e+00 3.83937166e+01 2.90834387 0.84996557 130.25 -3.71245307e+01 2.05779663e+01 4.24462422e+01 2.63545741 0.79023375 130.50 -3.47680308e+01 2.67493543e+01 4.38673446e+01 2.48581183 0.74117125 130.75 -3.80244167e+01 3.45693226e+01 5.13896325e+01 2.40375353 0.82645504 131.00 -3.69144317e+01 4.15488948e+01 5.55786463e+01 2.29719769 0.84071313 131.25 -2.88878945e+01 5.50223037e+01 6.21447050e+01 2.05426021 0.80600778 131.50 -1.75376259e+01 5.84070087e+01 6.09831697e+01 1.86249694 0.71375691 131.75 1.42720117e+01 4.57661252e+01 4.79398428e+01 1.26850681 0.55672737 132.00 2.14464873e+01 3.36594932e+01 3.99113179e+01 1.00350039 0.52994173 132.25 2.06578728e+01 6.91377109e+00 2.17841213e+01 0.32296181 0.47077214 132.50 1.39584746e+01 7.59239460e+00 1.58897284e+01 0.49816887 0.57569891 132.75 8.18356443e+00 1.18885488e+01 1.44328902e+01 0.96792735 0.77681161 133.00 7.16041773e+00 1.13810898e+01 1.34462183e+01 1.00921798 0.76662486 133.25 6.20464953e+00 1.02207765e+01 1.19566696e+01 1.02520003 0.76571257 133.50 4.11951534e+00 1.11016857e+01 1.18413611e+01 1.21547456 0.67859021 133.75 2.88877045e+00 1.27587201e+01 1.30816640e+01 1.34813511 0.75168549 134.00 3.31516969e+00 1.18151414e+01 1.22714268e+01 1.29724380 0.73987906 134.25 2.36930871e+00 9.75515140e+00 1.00387550e+01 1.33253216 0.75578362 134.50 -6.74232394e-01 9.18059607e+00 9.20532093e+00 1.64410574 0.74210710 134.75 -3.85566037e+00 8.86177815e+00 9.66422418e+00 1.98118115 0.85052238 135.00 -5.56102825e+00 8.14446881e+00 9.86191702e+00 2.16988389 0.81551525 135.25 -7.80202455e+00 7.94355902e+00 1.11342587e+01 2.34720590 0.85489649 135.50 -1.18333844e+01 7.84316150e+00 1.41966252e+01 2.55627208 0.83952025 135.75 -1.62223853e+01 7.94593836e+00 1.80638789e+01 2.68612765 0.87685341 136.00 -2.06007428e+01 9.50839673e+00 2.26892092e+01 2.70917041 0.82341159 136.25 -2.39747421e+01 1.43314867e+01 2.79316983e+01 2.60281124 0.78401804 136.50 -2.01516909e+01 1.37469605e+01 2.43940478e+01 2.54293087 0.64502428 136.75 -1.89439759e+01 1.49867527e+01 2.41552681e+01 2.47229652 0.63608680 137.00 -1.43492920e+01 9.34685934e+00 1.71250098e+01 2.56424706 0.49780226 137.25 -9.22542429e+00 1.44835098e+00 9.33842460e+00 2.98586817 0.27963919 137.50 -9.42276296e+00 -4.47556982e+00 1.04316435e+01 -2.69816532 0.26409413 137.75 -1.18620223e+01 -6.63628472e+00 1.35921980e+01 -2.63151822 0.37552780 138.00 -9.73577494e+00 -3.12053201e+00 1.02236507e+01 -2.83141609 0.30575793 138.25 -8.89278411e+00 -4.46601858e+00 9.95122762e+00 -2.67618099 0.34692409 138.50 -6.39876988e+00 -3.58191675e+00 7.33310191e+00 -2.63127024 0.34034895 138.75 -6.06052434e+00 -3.99342934e+00 7.25792210e+00 -2.55896902 0.43488942 139.00 -7.21092676e+00 -3.33475487e+00 7.94468721e+00 -2.70842662 0.51038187 139.25 -7.85307748e+00 -2.09127321e+00 8.12676132e+00 -2.88133277 0.49919839 139.50 -7.26516513e+00 1.15949844e+00 7.35710956e+00 2.98333037 0.44824359 139.75 -6.82847519e+00 1.17314645e+00 6.92851687e+00 2.97145153 0.43606940 140.00 -5.18917184e+00 5.60440345e-01 5.21934841e+00 3.03400778 0.18467854 140.25 -4.51346321e+00 -8.75069338e-01 4.59750982e+00 -2.95008877 0.12775586 140.50 -3.29192335e+00 3.20291065e-01 3.30746817e+00 3.04460191 0.07435951 140.75 -2.73792644e+00 6.94210971e-02 2.73880640e+00 3.11624273 0.05170463 141.00 -7.84113374e-01 -3.92664455e-01 8.76937374e-01 -2.67732515 0.00506016 141.25 -1.26956525e+00 6.42575396e-01 1.42291921e+00 2.67304660 0.01121200 141.50 -5.60907475e+00 4.43120729e+00 7.14823878e+00 2.47297489 0.11584967 141.75 -8.04220377e+00 2.90966290e+00 8.55237860e+00 2.79444521 0.11529279 142.00 -1.22958140e+01 -1.49515225e+00 1.23863846e+01 -3.02058824 0.13641479 142.25 -1.63161104e+01 4.58865391e+00 1.69490768e+01 2.86743952 0.22785230 142.50 -1.19142362e+01 1.50316836e+01 1.91807334e+01 2.24101382 0.21808086 142.75 -6.41360876e+00 2.15829818e+01 2.25157608e+01 1.85964600 0.28387125 143.00 7.35242526e+00 2.41833467e+01 2.52763212e+01 1.27564782 0.33543103 143.25 1.59757184e+01 2.54959589e+01 3.00876635e+01 1.01104867 0.42859297 143.50 2.88551130e+01 2.06855302e+01 3.55036435e+01 0.62196240 0.55397299 143.75 2.60943300e+01 1.05436275e+01 2.81439538e+01 0.38399990 0.50159987 144.00 2.70586794e+01 5.27552222e+00 2.75681567e+01 0.19255051 0.60859426 144.25 2.24441051e+01 2.07960997e+00 2.25402447e+01 0.09239348 0.43850850 144.50 1.59644944e+01 -2.96870621e+00 1.62381741e+01 -0.18385674 0.29515457 144.75 8.79222679e+00 -2.84084884e+00 9.23978755e+00 -0.31252073 0.15010476 145.00 6.22593372e+00 -1.76857302e+00 6.47225627e+00 -0.27677465 0.06699696 145.25 3.83282911e+00 3.99450629e-01 3.85358792e+00 0.10384334 0.02928328 145.50 3.03998000e-01 5.18251925e+00 5.19142760e+00 1.51220512 0.06472738 145.75 -3.19453243e+00 5.94175745e+00 6.74607434e+00 2.06410137 0.15064561 146.00 -2.11951051e+00 6.39471867e+00 6.73682059e+00 1.89084825 0.10833517 146.25 -3.03418067e+00 5.96481132e+00 6.69217650e+00 2.04136386 0.07144163 146.50 -3.33268141e+00 5.45410678e+00 6.39171700e+00 2.11929449 0.05965979 146.75 2.27565294e+00 1.00147942e+00 2.48627378e+00 0.41457761 0.01014542 147.00 1.19218549e+00 -3.38164634e-01 1.23921813e+00 -0.27639108 0.00301163 147.25 -1.08136842e+00 3.24958193e+00 3.42478326e+00 1.89204119 0.03634973 147.50 -1.79089804e-01 4.44874753e+00 4.45235081e+00 1.61103083 0.06259149 147.75 9.24856268e-01 3.52244297e+00 3.64183520e+00 1.31403090 0.06364215 148.00 1.15256231e+00 3.20100648e+00 3.40218200e+00 1.22518544 0.06700746 148.25 -1.90756698e-01 1.16238871e+00 1.17793702e+00 1.73345397 0.01197523 148.50 -2.21648952e+00 1.98297185e+00 2.97405500e+00 2.41174386 0.06638185 148.75 -3.48898401e+00 1.99044043e+00 4.01682244e+00 2.62315221 0.11221551 149.00 -2.60865756e+00 1.45659132e+00 2.98776715e+00 2.63234746 0.04802696 149.25 -9.19145556e-01 -4.83666563e-01 1.03863463e+00 -2.65719503 0.00508126 149.50 1.95230419e+00 1.00936436e+00 2.19779618e+00 0.47716427 0.02085169 149.75 3.99938061e+00 9.80179621e-01 4.11774178e+00 0.24034544 0.11281332 150.00 3.40088513e+00 1.47677159e+00 3.70767771e+00 0.40966379 0.09200296 150.25 4.17906755e+00 1.30295720e+00 4.37747679e+00 0.30223043 0.12926973 150.50 4.61967445e+00 1.97992439e+00 5.02608124e+00 0.40490347 0.20627520 150.75 2.98612902e+00 8.30149526e-01 3.09937328e+00 0.27115490 0.10525202 151.00 3.70179443e+00 1.10066725e+00 3.86196199e+00 0.28900861 0.16908158 151.25 3.77776934e+00 2.11972510e+00 4.33183284e+00 0.51132909 0.27349452 151.50 4.42207628e+00 1.94693804e+00 4.83170015e+00 0.41473884 0.29602904 151.75 3.95600614e+00 1.60556751e+00 4.26940647e+00 0.38554415 0.19137233 152.00 3.54088254e+00 1.48672652e+00 3.84033917e+00 0.39752136 0.17590549 152.25 1.68264776e+00 1.51908679e+00 2.26692041e+00 0.73435742 0.07459406 152.50 1.56186158e+00 1.88917665e+00 2.45120379e+00 0.87996068 0.07751168 152.75 3.73224561e+00 2.57358607e+00 4.53354194e+00 0.60368098 0.32269272 153.00 3.94397693e+00 2.50731168e+00 4.67349611e+00 0.56627939 0.31862781 153.25 3.18070340e+00 4.20432186e+00 5.27192530e+00 0.92312792 0.41547029 153.50 2.98444862e+00 3.47664373e+00 4.58191938e+00 0.86142963 0.34285765 153.75 2.26023800e+00 2.04103455e+00 3.04540602e+00 0.73447975 0.20581360 154.00 2.08896323e+00 2.27676518e+00 3.08989111e+00 0.82838898 0.17380415 154.25 2.53653336e+00 2.50397816e+00 3.56425422e+00 0.77893954 0.22235237 154.50 1.56375002e+00 2.71393253e+00 3.13221071e+00 1.04806564 0.14632569 154.75 2.06836770e+00 3.20528672e+00 3.81470941e+00 0.99773309 0.17844418 155.00 1.54806272e+00 2.11751375e+00 2.62304454e+00 0.93951723 0.10001086 155.25 3.19985087e+00 1.02621410e+00 3.36038108e+00 0.31034401 0.16220948 155.50 3.09846746e+00 1.42415219e+00 3.41008945e+00 0.43083427 0.15536755 155.75 2.94956189e+00 1.99815919e+00 3.56266129e+00 0.59542588 0.17209469 156.00 2.61532970e+00 2.28143512e+00 3.47057569e+00 0.71731678 0.14957204 156.25 2.64199403e+00 1.67386335e+00 3.12761106e+00 0.56473159 0.12706688 156.50 1.99763830e+00 2.47369739e+00 3.17958135e+00 0.89146768 0.16101616 156.75 2.73284043e+00 3.21187874e+00 4.21717700e+00 0.86580658 0.27032044 157.00 1.21869002e+00 2.90437915e+00 3.14970214e+00 1.17350474 0.17531181 157.25 9.54124955e-01 2.86649001e+00 3.02111228e+00 1.24947652 0.14687673 157.50 1.60035775e+00 2.53030165e+00 2.99392241e+00 1.00683831 0.14242608 157.75 1.54939395e+00 2.05069750e+00 2.57021047e+00 0.92375594 0.12923690 158.00 1.54805989e+00 3.00011781e+00 3.37597339e+00 1.09443104 0.19228978 158.25 2.71165984e+00 3.03219403e+00 4.06783723e+00 0.84114507 0.24545003 158.50 2.58305033e+00 2.58508040e+00 3.65442057e+00 0.78579097 0.21984659 158.75 2.33011409e+00 3.55097692e+00 4.24721895e+00 0.99008220 0.28203437 159.00 2.38168274e+00 5.32988790e+00 5.83781789e+00 1.15056154 0.36680658 159.25 2.02420416e+00 6.48909090e+00 6.79747770e+00 1.26842212 0.39833852 159.50 1.53704052e+00 6.37239550e+00 6.55514439e+00 1.33411423 0.41228113 159.75 9.14828998e-01 7.98400402e+00 8.03624492e+00 1.45671114 0.54157205 160.00 2.15048997e+00 7.10760968e+00 7.42581460e+00 1.27699107 0.32903085 160.25 2.86291008e+00 6.52540689e+00 7.12581148e+00 1.15735160 0.34212316 160.50 3.83304719e+00 5.68545865e+00 6.85687180e+00 0.97760722 0.38995179 160.75 3.97918822e+00 4.92582513e+00 6.33227384e+00 0.89130425 0.39695241 161.00 3.23264466e+00 5.74185816e+00 6.58930396e+00 1.05802997 0.58349092 161.25 2.07772970e+00 5.55465652e+00 5.93052862e+00 1.21285715 0.57533697 161.50 3.95833800e-01 5.72692751e+00 5.74059084e+00 1.50178807 0.61801228 161.75 -6.08743017e-03 5.88090274e+00 5.88090589e+00 1.57183144 0.63558390 162.00 -8.23907841e-01 5.18243750e+00 5.24752156e+00 1.72845763 0.60179033 162.25 -1.68570405e+00 4.84752046e+00 5.13225611e+00 1.90546139 0.58540861 162.50 -2.75627314e+00 4.40813015e+00 5.19890883e+00 2.12959004 0.63584441 162.75 -2.74385707e+00 3.55651452e+00 4.49194247e+00 2.22791712 0.50364207 163.00 -3.55352567e+00 3.53201989e+00 5.01026040e+00 2.35922964 0.32677383 163.25 -3.10724501e+00 4.31707392e+00 5.31903175e+00 2.19465945 0.30064129 163.50 -1.84106253e+00 5.44124342e+00 5.74427029e+00 1.89705800 0.38893149 163.75 -1.50222582e+00 4.91240594e+00 5.13696550e+00 1.86756794 0.46331049 164.00 -1.22472769e+00 4.73785046e+00 4.89358610e+00 1.82375754 0.61520856 164.25 -2.12087370e+00 4.05221816e+00 4.57368312e+00 2.05297712 0.64751788 164.50 -2.99766200e+00 3.53561376e+00 4.63535782e+00 2.27403954 0.72508657 164.75 -3.12513676e+00 3.08902279e+00 4.39414856e+00 2.36200599 0.62131360 165.00 -3.41833247e+00 3.01532739e+00 4.55820097e+00 2.41875285 0.60887871 165.25 -3.23485023e+00 2.25332001e+00 3.94229718e+00 2.53316817 0.45094379 165.50 -2.97236429e+00 9.63761403e-01 3.12470567e+00 2.82804769 0.30731605 165.75 -2.67870361e+00 1.45870848e+00 3.05012843e+00 2.64293745 0.26262227 166.00 -3.62358234e+00 1.41918723e+00 3.89158597e+00 2.76830253 0.34636008 166.25 -3.58129475e+00 2.57264601e+00 4.40955548e+00 2.51865290 0.40632521 166.50 -3.61391419e+00 3.71664915e+00 5.18400007e+00 2.34218080 0.64401063 166.75 -3.41843084e+00 3.15022515e+00 4.64861140e+00 2.39700296 0.61438870 167.00 -3.90611469e+00 2.45234425e+00 4.61212796e+00 2.58096670 0.71317688 167.25 -3.95516458e+00 2.44949326e+00 4.65224076e+00 2.58709178 0.73326072 167.50 -4.22157909e+00 2.24471346e+00 4.78126223e+00 2.65288938 0.81727356 167.75 -4.45921443e+00 1.57724831e+00 4.72993716e+00 2.80162061 0.79519140 168.00 -4.53254543e+00 1.36720299e+00 4.73425940e+00 2.84863074 0.82969420 168.25 -4.42333086e+00 1.19496327e+00 4.58189841e+00 2.87774092 0.81839695 168.50 -4.62304097e+00 1.23289598e+00 4.78461496e+00 2.88097308 0.82098505 168.75 -4.59944870e+00 1.29058500e+00 4.77708468e+00 2.86803175 0.73600511 169.00 -4.55137332e+00 1.31158818e+00 4.73658765e+00 2.86102025 0.77384517 169.25 -4.63260771e+00 2.00343468e+00 5.04725715e+00 2.73341721 0.76430959 169.50 -4.36812282e+00 2.15750897e+00 4.87189306e+00 2.68281981 0.78603341 169.75 -3.92316365e+00 1.52728830e+00 4.20996705e+00 2.77034416 0.78246849 170.00 -4.02941925e+00 1.28251745e+00 4.22860148e+00 2.83344308 0.75897581 170.25 -4.16125593e+00 7.45595172e-01 4.22752446e+00 2.96429844 0.76456640 170.50 -4.29377413e+00 7.37863946e-01 4.35671200e+00 2.97140979 0.77959895 170.75 -4.73065036e+00 3.32906193e-01 4.74234956e+00 3.07133629 0.75933834 171.00 -4.72999152e+00 2.42487199e-01 4.73620310e+00 3.09037161 0.74543663 171.25 -3.89637656e+00 -1.37715364e-01 3.89880954e+00 -3.10626289 0.61160368 171.50 -3.98666923e+00 1.38373051e-02 3.98669324e+00 3.13812177 0.68141700 171.75 -4.49229757e+00 6.40459620e-01 4.53772255e+00 2.99997859 0.73400452 172.00 -4.68311178e+00 1.01844079e+00 4.79257317e+00 2.92745591 0.70760881 172.25 -3.48525058e+00 8.54748665e-01 3.58853269e+00 2.90109200 0.44881471 172.50 -2.62431340e+00 1.72289043e+00 3.13932672e+00 2.56065394 0.39109659 172.75 -2.35841967e+00 2.07583868e+00 3.14185448e+00 2.41983521 0.50432112 173.00 -2.14443624e+00 1.69027614e+00 2.73050183e+00 2.47407931 0.52670486 173.25 -2.27335284e+00 1.04954975e+00 2.50393447e+00 2.70907248 0.64198716 173.50 -2.29729396e+00 5.41734419e-01 2.36030415e+00 2.91000929 0.61065738 173.75 -2.72953537e+00 -3.08365525e-01 2.74689873e+00 -3.02909600 0.68112500 174.00 -2.55505022e+00 -3.92065067e-01 2.58495583e+00 -2.98933317 0.62657132 174.25 -2.61528990e+00 -5.88043629e-01 2.68058512e+00 -2.92042255 0.61153845 174.50 -2.77681072e+00 -8.61129320e-01 2.90727045e+00 -2.84088251 0.61128599 174.75 -3.07108652e+00 -1.46387349e+00 3.40213139e+00 -2.69678829 0.56796381 175.00 -3.40970259e+00 -1.22751679e+00 3.62393008e+00 -2.79603088 0.53452631 175.25 -1.80082943e+00 -2.21798235e+00 2.85699709e+00 -2.25276483 0.40423173 175.50 -7.19997290e-01 -2.83572235e+00 2.92569946e+00 -1.81944464 0.24149678 175.75 -4.67178691e+00 -5.18312803e-01 4.70045116e+00 -3.03109922 0.16506123 176.00 -4.92436055e+00 4.13162687e+00 6.42803761e+00 2.44350889 0.44538619 176.25 -4.16938478e+00 4.58000184e+00 6.19356007e+00 2.30929795 0.74241034 176.50 -3.90237886e+00 3.67290996e+00 5.35899509e+00 2.38647700 0.68718171 176.75 -4.10926131e+00 2.58164561e+00 4.85292927e+00 2.58065929 0.65249206 177.00 -4.17630074e+00 2.06714528e+00 4.65989028e+00 2.68197681 0.66243103 177.25 -4.50689828e+00 2.04089528e+00 4.94746254e+00 2.71638107 0.70697784 177.50 -4.21623634e+00 2.29945249e+00 4.80251295e+00 2.64230311 0.71105799 177.75 -4.22898934e+00 2.32373812e+00 4.82536109e+00 2.63915002 0.78645741 178.00 -4.01700005e+00 2.18641516e+00 4.57347796e+00 2.64314346 0.80554941 178.25 -4.21341457e+00 2.02575298e+00 4.67509759e+00 2.69343363 0.85066375 178.50 -4.24570941e+00 1.77280866e+00 4.60096717e+00 2.74604656 0.80778662 178.75 -4.28637204e+00 1.94115448e+00 4.70542942e+00 2.71635747 0.83328443 179.00 -4.32494649e+00 1.74341790e+00 4.66311785e+00 2.75841036 0.82793071 179.25 -4.51105484e+00 1.46184426e+00 4.74200426e+00 2.82821283 0.87137997 179.50 -4.66997621e+00 1.43580091e+00 4.88571407e+00 2.84331182 0.83681933 179.75 -4.62125392e+00 1.72461605e+00 4.93257421e+00 2.78440782 0.82511658 180.00 -4.30758893e+00 1.47141305e+00 4.55196428e+00 2.81243297 0.81660188 180.25 -4.61014944e+00 1.11146207e+00 4.74223848e+00 2.90501706 0.84649297 180.50 -5.36031229e+00 1.42669659e+00 5.54692807e+00 2.88146407 0.85852257 180.75 -5.33681159e+00 1.60594219e+00 5.57320449e+00 2.84929395 0.87557203 181.00 -5.40811137e+00 1.38390061e+00 5.58236953e+00 2.89107489 0.79856171 181.25 -5.59911114e+00 1.35828869e+00 5.76150968e+00 2.90360012 0.78183372 181.50 -5.99578460e+00 1.74529496e+00 6.24463670e+00 2.85833285 0.68444999 181.75 -6.18207554e+00 1.84486780e+00 6.45148008e+00 2.85158413 0.70456468 182.00 -5.67405964e+00 1.53317118e+00 5.87754767e+00 2.87768780 0.64239348 182.25 -4.93920531e+00 1.08099922e+00 5.05611594e+00 2.92612906 0.53306888 182.50 -4.88546320e+00 3.14792538e-01 4.89559445e+00 3.07724707 0.40216623 182.75 -4.26613697e+00 5.46737421e-01 4.30102853e+00 3.01412996 0.33157793 183.00 -4.67704846e+00 -1.75157664e+00 4.99427703e+00 -2.78325629 0.27574119 183.25 -4.22364076e+00 -2.16097295e+00 4.74435932e+00 -2.66867846 0.23225057 183.50 -2.91579522e+00 -2.92479294e+00 4.12992439e+00 -2.35465394 0.15099361 183.75 -3.38809715e+00 -3.03294545e+00 4.54730254e+00 -2.41144879 0.19293156 184.00 -1.68827861e+00 -1.17062844e+00 2.05442342e+00 -2.53531955 0.04178914 184.25 6.30939269e-01 -2.79907186e+00 2.86930090e+00 -1.34909151 0.07935656 184.50 4.52698028e+00 -5.66714046e+00 7.25327729e+00 -0.89678014 0.41192057 184.75 5.39343651e+00 -3.84433559e+00 6.62329778e+00 -0.61925198 0.46070116 185.00 6.28918222e+00 -1.56370566e+00 6.48066265e+00 -0.24369277 0.68873733 185.25 6.55336761e+00 -5.92264205e-01 6.58007628e+00 -0.09013069 0.73741802 185.50 6.19745246e+00 9.04843643e-03 6.19745907e+00 0.00146002 0.78708645 185.75 5.49202931e+00 4.82613970e-01 5.51319347e+00 0.08765019 0.74250892 186.00 5.36779969e+00 8.77046509e-01 5.43897822e+00 0.16195920 0.81185796 186.25 4.43949862e+00 6.07135892e-01 4.48082158e+00 0.13591462 0.79129426 186.50 3.73035057e+00 7.71401732e-01 3.80927499e+00 0.20391645 0.84009869 186.75 3.20815464e+00 1.15819355e+00 3.41081639e+00 0.34645428 0.79808820 187.00 2.76849950e+00 1.63635211e+00 3.21593497e+00 0.53382079 0.84441996 187.25 2.51811579e+00 2.00928922e+00 3.22151367e+00 0.67347968 0.78447325 187.50 2.39602631e+00 2.36480318e+00 3.36648721e+00 0.77883992 0.85135574 187.75 1.96620647e+00 2.48695667e+00 3.17031881e+00 0.90180885 0.78672077 188.00 1.81663781e+00 2.82798853e+00 3.36120397e+00 0.99979790 0.82277779 188.25 1.69561972e+00 3.40119510e+00 3.80042818e+00 1.10832025 0.79282740 188.50 1.70301284e+00 3.81035387e+00 4.17361346e+00 1.15048710 0.83060012 188.75 2.11072503e+00 3.72652805e+00 4.28277614e+00 1.05544522 0.66610087 189.00 3.26645365e+00 3.97018512e+00 5.14121478e+00 0.88233898 0.75186031 189.25 4.01383814e+00 3.32670180e+00 5.21323714e+00 0.69206173 0.69943608 189.50 4.02591286e+00 2.91002376e+00 4.96751574e+00 0.62587998 0.72973266 189.75 3.88764810e+00 2.17399538e+00 4.45421864e+00 0.50988352 0.70800280 190.00 3.73909837e+00 1.68426232e+00 4.10092626e+00 0.42322485 0.73680594 190.25 3.12595844e+00 1.66731465e+00 3.54281728e+00 0.48999140 0.72796572 190.50 2.86874460e+00 1.72560064e+00 3.34774449e+00 0.54153471 0.77992510 190.75 2.97678088e+00 1.62410571e+00 3.39100925e+00 0.49945210 0.72921550 191.00 2.83559162e+00 1.65632880e+00 3.28390087e+00 0.52866198 0.78049887 191.25 2.92382071e+00 1.87618051e+00 3.47401509e+00 0.57050974 0.75990998 191.50 2.76278608e+00 1.85216207e+00 3.32618268e+00 0.59058034 0.73736933 191.75 2.41493139e+00 1.58913128e+00 2.89088772e+00 0.58200933 0.71677864 192.00 2.32243852e+00 1.75415502e+00 2.91046053e+00 0.64688921 0.75347511 192.25 2.89662784e+00 1.92154635e+00 3.47603125e+00 0.58571930 0.82895405 192.50 2.97271318e+00 1.90822583e+00 3.53247073e+00 0.57066975 0.87518006 192.75 3.05544461e+00 2.30807995e+00 3.82922640e+00 0.64694755 0.83450462 193.00 3.18853226e+00 2.43225731e+00 4.01031341e+00 0.65165181 0.81876351 193.25 3.44951330e+00 2.07938143e+00 4.02777471e+00 0.54247893 0.85942179 193.50 3.60688436e+00 1.97965189e+00 4.11444242e+00 0.50196272 0.84019359 193.75 3.95833270e+00 1.48514923e+00 4.22777317e+00 0.35894219 0.87895355 194.00 3.76287028e+00 1.29936250e+00 3.98089634e+00 0.33249192 0.88162616 194.25 3.33876806e+00 1.15347057e+00 3.53240237e+00 0.33264055 0.86147654 194.50 3.47893222e+00 9.83465581e-01 3.61526956e+00 0.27550305 0.81035689 194.75 4.06341178e+00 7.90996039e-01 4.13968477e+00 0.19225863 0.83542394 195.00 3.88292237e+00 2.55146379e-01 3.89129616e+00 0.06561555 0.77034671 195.25 3.51747572e+00 -3.71478096e-01 3.53703709e+00 -0.10521926 0.77990618 195.50 3.28143738e+00 -5.36122414e-01 3.32494489e+00 -0.16194949 0.68314520 195.75 2.92449924e+00 -8.64541177e-01 3.04961100e+00 -0.28743384 0.62560328 196.00 2.27379980e+00 -1.06104389e+00 2.50917909e+00 -0.43660452 0.38538685 196.25 -5.58243870e-01 -1.69451251e+00 1.78409890e+00 -1.88904075 0.17025671 196.50 -1.62283993e+00 3.67000232e-01 1.66382049e+00 2.91918684 0.19589569 196.75 -2.04219909e+00 1.12731418e+00 2.33268394e+00 2.63720762 0.61454102 197.00 -2.45507368e+00 1.67885118e+00 2.97421049e+00 2.54180219 0.61742017 197.25 -3.23474807e+00 1.60910727e+00 3.61286884e+00 2.67999162 0.42739326 197.50 9.07873925e-02 3.11237000e-01 3.24207990e-01 1.28697280 0.00647556 197.75 1.15194207e+00 4.89089427e-01 1.25147073e+00 0.40151328 0.42377330 198.00 1.28147331e+00 1.29127877e+00 1.81922365e+00 0.78920942 0.70043501 198.25 1.45509410e+00 1.91082940e+00 2.40178430e+00 0.91997658 0.88648767 198.50 1.65171078e+00 2.28381690e+00 2.81850459e+00 0.94465335 0.89474186 198.75 1.96645475e+00 2.59872217e+00 3.25888036e+00 0.92302058 0.92175094 199.00 2.44174553e+00 2.81222402e+00 3.72434225e+00 0.85579566 0.89970183 199.25 2.87763967e+00 2.83475682e+00 4.03938811e+00 0.77789132 0.91344556 199.50 3.28033264e+00 2.42205566e+00 4.07761400e+00 0.63600767 0.81423465 199.75 3.66124113e+00 1.94782136e+00 4.14713090e+00 0.48892743 0.84906306 200.00 2.91060051e+00 1.87341560e+00 3.46139876e+00 0.57190013 0.81766676 200.25 2.82700163e+00 1.95815169e+00 3.43893825e+00 0.60578296 0.81627572 200.50 3.81612530e+00 1.77534579e+00 4.20887930e+00 0.43544026 0.75933667 200.75 4.10098495e+00 1.13124188e+00 4.25414924e+00 0.26915292 0.73452450 201.00 3.08322215e+00 8.55907178e-01 3.19981811e+00 0.27078322 0.54399010 201.25 2.82578167e+00 9.22028702e-01 2.97240289e+00 0.31539962 0.53455875 201.50 2.84010355e+00 1.40659125e+00 3.16933543e+00 0.45984887 0.58407771 201.75 3.20761261e+00 1.44183418e+00 3.51676904e+00 0.42244124 0.60068291 202.00 3.51502454e+00 3.04950968e-01 3.52822797e+00 0.08653974 0.45970317 202.25 3.52442736e+00 -2.76497121e-01 3.53525655e+00 -0.07829129 0.41579449 202.50 2.55381998e+00 -8.12283459e-01 2.67988822e+00 -0.30794766 0.30051573 202.75 2.34344280e+00 -8.73367155e-01 2.50089871e+00 -0.35673998 0.31791436 203.00 2.20646793e+00 -1.02391815e+00 2.43246975e+00 -0.43447878 0.31429328 203.25 1.92545044e+00 -7.37053656e-01 2.06170015e+00 -0.36558746 0.25241705 203.50 1.16795753e+00 1.85135325e-01 1.18253959e+00 0.15720410 0.12648959 203.75 9.77669183e-01 8.08179156e-01 1.26845992e+00 0.69077430 0.12410279 204.00 1.52155511e+00 1.54824945e+00 2.17076169e+00 0.79409372 0.21326479 204.25 1.96611514e+00 1.90821674e+00 2.73987223e+00 0.77045518 0.27157398 204.50 3.19041425e+00 2.15415990e+00 3.84956465e+00 0.59388537 0.38932922 204.75 3.70573293e+00 1.66723258e+00 4.06351092e+00 0.42277600 0.37555229 205.00 4.44640531e+00 -1.09041366e-01 4.44774215e+00 -0.02451857 0.44782637 205.25 3.86976157e+00 -1.20404972e+00 4.05275096e+00 -0.30164824 0.35159266 205.50 2.64119357e+00 -2.10046916e+00 3.37459245e+00 -0.67185179 0.26424958 205.75 1.50048756e+00 -8.49567436e-01 1.72430500e+00 -0.51519135 0.07720122 206.00 -4.71507232e-02 -4.92871130e-03 4.74076249e-02 -3.03743992 0.00012184 206.25 6.87484431e-01 6.67763433e-01 9.58406409e-01 0.77084761 0.04373371 206.50 1.68208811e+00 1.29132459e+00 2.12059888e+00 0.65472780 0.20892565 206.75 2.16351548e+00 1.38569286e+00 2.56923022e+00 0.56965510 0.25889133 207.00 2.25823438e+00 1.27177371e+00 2.59172354e+00 0.51289957 0.28510694 207.25 2.17442264e+00 1.46834090e+00 2.62376424e+00 0.59394098 0.22651419 207.50 2.93979572e+00 1.80807276e+00 3.45130786e+00 0.55140025 0.28643034 207.75 2.68782735e+00 1.75624702e+00 3.21073504e+00 0.57876705 0.22102497 208.00 3.20618534e+00 1.50701356e+00 3.54269873e+00 0.43938808 0.25674669 208.25 2.58957784e+00 1.41427316e+00 2.95060704e+00 0.49987518 0.16937915 208.50 2.44878976e+00 1.61966099e+00 2.93596203e+00 0.58435651 0.17695481 208.75 3.53106555e+00 1.46901488e+00 3.82445142e+00 0.39424506 0.28598304 209.00 4.38676249e+00 1.09829189e+00 4.52215990e+00 0.24532218 0.40118352 209.25 3.12537293e+00 1.56261460e+00 3.49424103e+00 0.46362921 0.20762873 209.50 3.86750205e+00 2.34077130e+00 4.52070596e+00 0.54426436 0.31055409 209.75 3.26202995e+00 2.58138747e+00 4.15985585e+00 0.66944049 0.19418496 210.00 2.67772735e+00 3.33672784e+00 4.27831467e+00 0.89453226 0.12619238 210.25 5.66195879e-02 -2.01973572e+00 2.02052917e+00 -1.54277050 0.01606792 210.50 -2.50824477e+00 -8.96693391e+00 9.31113289e+00 -1.84354682 0.26963094 210.75 -4.23142779e+00 -8.39295256e+00 9.39928900e+00 -2.03776989 0.29409129 211.00 -6.34072033e+00 -7.12586270e+00 9.53848277e+00 -2.29795740 0.32365151 211.25 -6.67591125e+00 -3.84686252e+00 7.70494271e+00 -2.61883424 0.39690585 211.50 -7.04403293e+00 -2.65997433e+00 7.52953274e+00 -2.78052616 0.50062326 211.75 -4.18560746e+00 -7.22151341e-01 4.24744775e+00 -2.97074262 0.31205236 212.00 -2.61420551e+00 -5.98489957e-01 2.68183904e+00 -2.91653351 0.22519034 212.25 -7.34352499e-01 -3.44883276e-01 8.11306395e-01 -2.70252448 0.03124110 212.50 -1.40393773e-01 -3.71159104e-01 3.96824258e-01 -1.93241996 0.01151047 212.75 1.35000982e-01 -3.93711440e-01 4.16213843e-01 -1.24046669 0.01173341 213.00 1.74432313e-01 -6.63795300e-01 6.86331430e-01 -1.31382580 0.02499168 213.25 6.77762173e-01 -1.55564042e+00 1.69687320e+00 -1.15991410 0.13891740 213.50 6.70470196e-01 -1.59273766e+00 1.72810403e+00 -1.17235718 0.16296532 213.75 8.14478886e-01 -2.06850597e+00 2.22308182e+00 -1.19568751 0.29590155 214.00 1.44357329e+00 -1.95239165e+00 2.42811387e+00 -0.93412212 0.35604468 214.25 1.81648792e+00 -2.18268501e+00 2.83967291e+00 -0.87671173 0.42228957 214.50 1.60543185e+00 -2.71126183e+00 3.15092877e+00 -1.03618030 0.40238058 214.75 6.79189567e-01 -4.88161146e+00 4.92863358e+00 -1.43255156 0.55005191 215.00 2.34016947e-01 -4.99518741e+00 5.00066607e+00 -1.52398207 0.48917667 215.25 4.09680460e-01 -4.92201736e+00 4.93903766e+00 -1.48775349 0.38519604 215.50 3.41478221e-02 -3.94578084e+00 3.94592860e+00 -1.56214228 0.21864610 215.75 -1.60994079e+00 -1.08836616e+00 1.94330910e+00 -2.54713663 0.04861698 216.00 -1.21781349e+00 3.75443029e-01 1.27437324e+00 2.84254533 0.02599287 216.25 -1.08362874e+00 1.52734922e+00 1.87271111e+00 2.18785860 0.08000980 216.50 -4.48984134e-01 1.25322262e+00 1.33122263e+00 1.91481394 0.06026805 216.75 -2.17772924e-01 1.03084950e+00 1.05360132e+00 1.77899096 0.07530200 217.00 3.67689437e-01 6.37559110e-01 7.35987188e-01 1.04767468 0.03454661 217.25 1.13467167e+00 4.98628937e-01 1.23939930e+00 0.41404412 0.14836662 217.50 1.47232829e+00 1.87614683e-01 1.48423376e+00 0.12674414 0.21492433 217.75 1.85536751e+00 -3.16346216e-01 1.88214333e+00 -0.16887924 0.42765268 218.00 1.65757212e+00 -5.41202676e-01 1.74368738e+00 -0.31559093 0.33688269 218.25 1.40380571e+00 -8.55860491e-01 1.64413128e+00 -0.54750065 0.34030270 218.50 1.74424345e+00 -9.84526561e-01 2.00291731e+00 -0.51386446 0.37229014 218.75 2.08024297e+00 -8.43416900e-01 2.24471888e+00 -0.38518853 0.46797239 219.00 1.55874738e+00 -1.02075929e+00 1.86323453e+00 -0.57978325 0.28296355 219.25 1.21655969e+00 -1.23781008e+00 1.73556656e+00 -0.79405614 0.30940881 219.50 1.40510293e+00 -1.41068113e+00 1.99106391e+00 -0.78737921 0.35990081 219.75 1.37615298e+00 -1.59960853e+00 2.11010532e+00 -0.86034939 0.47996922 220.00 1.60625021e+00 -1.61713751e+00 2.27929232e+00 -0.78877574 0.39591680 220.25 1.67881316e+00 -2.21813361e+00 2.78182141e+00 -0.92292024 0.47105643 220.50 2.24441328e+00 -2.58984937e+00 3.42705570e+00 -0.85673272 0.57643933 220.75 2.41653674e+00 -2.87282036e+00 3.75403072e+00 -0.87144961 0.64386479 221.00 2.10003922e+00 -3.16024930e+00 3.79438274e+00 -0.98428347 0.55193072 221.25 1.60430203e+00 -3.77711732e+00 4.10370567e+00 -1.16914386 0.60557521 221.50 1.67917737e+00 -3.91682751e+00 4.26159294e+00 -1.16578872 0.55018140 221.75 1.37166611e+00 -4.28964388e+00 4.50361106e+00 -1.26130908 0.55692418 222.00 6.43549607e-01 -4.19276503e+00 4.24186688e+00 -1.41849445 0.54972609 222.25 2.67561718e-01 -4.39833257e+00 4.40646328e+00 -1.51003867 0.60801696 222.50 1.34376093e-01 -4.42909846e+00 4.43113643e+00 -1.54046625 0.56797298 222.75 -4.30678851e-01 -4.62698561e+00 4.64698613e+00 -1.66360870 0.58848106 223.00 -1.41892112e+00 -3.35126715e+00 3.63927584e+00 -1.97130962 0.50235159 223.25 -1.49943157e+00 -2.64851649e+00 3.04350696e+00 -2.08594672 0.43599667 223.50 2.92636522e-02 -1.85694404e+00 1.85717461e+00 -1.55503859 0.19858004 223.75 8.41373177e-01 -2.16898841e+00 2.32646073e+00 -1.20075526 0.29260513 224.00 1.68961799e+00 -3.44643256e+00 3.83832077e+00 -1.11497806 0.53215644 224.25 1.64608185e+00 -4.01289981e+00 4.33738981e+00 -1.18152995 0.54906628 224.50 5.84546175e-01 -5.48438148e+00 5.51544508e+00 -1.46461341 0.60369758 224.75 -1.34252034e-01 -6.69434926e+00 6.69569531e+00 -1.59084817 0.64927615 225.00 -1.16599288e+00 -6.21538284e+00 6.32380607e+00 -1.75623887 0.57727741 225.25 -2.35008970e+00 -5.90152305e+00 6.35223550e+00 -1.94976511 0.60119419 225.50 -3.72945307e+00 -6.26662791e+00 7.29242385e+00 -2.10762664 0.69678885 225.75 -3.51906921e+00 -5.50915103e+00 6.53717013e+00 -2.13923500 0.70451270 226.00 -3.19114421e+00 -5.23130155e+00 6.12779873e+00 -2.11854334 0.75662025 226.25 -3.26830518e+00 -5.81250690e+00 6.66836226e+00 -2.08302503 0.71525589 226.50 -3.96151000e+00 -7.70971897e+00 8.66794832e+00 -2.04544920 0.82013421 226.75 -4.62452045e+00 -7.90512614e+00 9.15845012e+00 -2.10011544 0.77688785 227.00 -5.97583621e+00 -7.64148255e+00 9.70066358e+00 -2.23448087 0.74169008 227.25 -7.28229051e+00 -6.39773043e+00 9.69343642e+00 -2.42076533 0.69485581 227.50 -9.40692022e+00 -5.95710885e+00 1.11345091e+01 -2.57706934 0.80107453 227.75 -1.04114141e+01 -4.96271826e+00 1.15336948e+01 -2.69678971 0.78661819 228.00 -1.16109180e+01 -2.28811521e+00 1.18342253e+01 -2.94702000 0.80779949 228.25 -1.11473215e+01 6.14550365e-01 1.11642487e+01 3.08651854 0.72777939 228.50 -1.23729403e+01 3.05441464e+00 1.27443753e+01 2.89956913 0.81229792 228.75 -1.00023843e+01 4.99938526e+00 1.11821977e+01 2.67808957 0.79620487 229.00 -8.51884085e+00 6.06799317e+00 1.04590244e+01 2.52265749 0.85077094 229.25 -6.76035848e+00 5.39356987e+00 8.64829710e+00 2.46818053 0.78272602 229.50 -6.02431945e+00 5.29846963e+00 8.02285518e+00 2.42021211 0.83456058 229.75 -4.91208498e+00 5.33425378e+00 7.25140278e+00 2.31501586 0.70849678 230.00 -3.71827033e+00 5.92735237e+00 6.99707370e+00 2.13105297 0.70477666 230.25 -2.92693315e+00 5.43882648e+00 6.17638820e+00 2.06450024 0.68225095 230.50 -2.39897377e+00 5.87645696e+00 6.34726883e+00 1.95838138 0.72951109 230.75 -1.23747551e+00 5.76239495e+00 5.89377139e+00 1.78233372 0.69921099 231.00 -8.21061983e-01 5.57737125e+00 5.63748284e+00 1.71695957 0.67777771 231.25 -3.18612500e-01 4.64044821e+00 4.65137330e+00 1.63934859 0.62841787 231.50 -4.20673626e-01 4.09756244e+00 4.11909993e+00 1.67310226 0.62696452 231.75 3.36959397e-01 4.12734445e+00 4.14107641e+00 1.48933626 0.58008340 232.00 9.70436366e-01 4.04752206e+00 4.16223276e+00 1.33547771 0.63416051 232.25 6.11102918e-01 2.90345254e+00 2.96706647e+00 1.36334965 0.40487665 232.50 5.74811516e-01 2.61878941e+00 2.68113153e+00 1.35472764 0.38392879 232.75 7.03954706e-01 1.98903688e+00 2.10993363e+00 1.23063591 0.25672693 233.00 9.90096385e-01 1.71321360e+00 1.97873487e+00 1.04677212 0.24257938 233.25 7.35170361e-01 1.26220204e+00 1.46069485e+00 1.04338074 0.13960748 233.50 6.88205426e-01 9.25695455e-01 1.15348983e+00 0.93150240 0.10019968 233.75 3.22776762e-01 4.58430483e-01 5.60663309e-01 0.95733002 0.02410236 234.00 2.62521628e-01 2.21231820e-01 3.43309078e-01 0.70025153 0.00952920 234.25 5.26927282e-01 1.14406139e+00 1.25957486e+00 1.13918224 0.11185926 234.50 3.42586767e-01 1.04591633e+00 1.10059377e+00 1.25426247 0.09326190 234.75 -5.54674302e-01 1.64905150e-01 5.78668549e-01 2.85261396 0.03167461 235.00 -6.45989068e-01 1.35500905e-01 6.60047250e-01 2.93483295 0.04142646 235.25 -4.28588823e-01 1.70454350e-01 4.61240788e-01 2.76306139 0.02276381 235.50 -6.66650841e-01 1.65238867e-01 6.86824015e-01 2.89862518 0.04041027 235.75 -9.18326445e-01 5.43697554e-01 1.06720686e+00 2.60703733 0.10752291 236.00 -7.97765588e-01 6.51872010e-01 1.03022670e+00 2.45649817 0.08711898 236.25 -8.74227632e-01 9.17342742e-01 1.26719835e+00 2.33213359 0.16914893 236.50 -1.01619764e+00 9.70343413e-01 1.40507081e+00 2.37927284 0.18102999 236.75 -7.66087672e-01 8.16121168e-01 1.11934985e+00 2.32458246 0.16198451 237.00 -6.84192787e-01 7.35542248e-01 1.00456068e+00 2.32004191 0.12841051 237.25 -9.36451956e-01 3.78513740e-01 1.01005689e+00 2.75747097 0.13373436 237.50 -8.61377646e-01 4.47039715e-01 9.70472027e-01 2.66287482 0.10249653 237.75 -1.18438876e+00 1.59845191e-02 1.18449662e+00 3.12809747 0.19967330 238.00 -1.49986847e+00 2.35011882e-01 1.51816864e+00 2.98616806 0.24596768 238.25 -2.13237438e+00 4.09238302e-01 2.17128913e+00 2.95198142 0.36062243 238.50 -1.98509656e+00 1.09298956e+00 2.26610558e+00 2.63829069 0.33468072 238.75 -1.29539873e+00 1.23144921e+00 1.78732342e+00 2.38149711 0.27454026 239.00 -1.30673063e+00 9.50201796e-01 1.61568202e+00 2.51287033 0.17802251 239.25 -1.83574547e+00 7.15733931e-01 1.97033918e+00 2.76983436 0.26857488 239.50 -2.21514180e+00 8.55406150e-01 2.37456794e+00 2.77307120 0.37598774 239.75 -2.54774352e+00 1.06531389e+00 2.76150153e+00 2.74554667 0.54677459 240.00 -1.94256753e+00 2.14921347e+00 2.89701349e+00 2.30573467 0.43827509 240.25 -1.92599937e+00 3.15048754e+00 3.69256622e+00 2.11950782 0.55551409 240.50 -2.05864190e+00 3.50933671e+00 4.06859320e+00 2.10131839 0.57110514 240.75 -1.47652085e+00 3.74087382e+00 4.02172236e+00 1.94672493 0.54371497 241.00 2.04727841e-01 3.62567628e+00 3.63145177e+00 1.51439011 0.47707796 241.25 1.10727370e+00 3.61875549e+00 3.78436868e+00 1.27386062 0.60626014 241.50 9.09849122e-01 2.79399268e+00 2.93840441e+00 1.25598136 0.49544060 241.75 1.34806675e+00 2.30758688e+00 2.67249718e+00 1.04208373 0.49099194 242.00 1.43933735e+00 1.17447952e+00 1.85771207e+00 0.68441294 0.34032195 242.25 1.27109878e+00 8.43223117e-01 1.52535810e+00 0.58572464 0.33901103 242.50 1.40568823e+00 8.69847824e-01 1.65305615e+00 0.55413255 0.40551979 242.75 1.50652603e+00 7.41266633e-01 1.67901665e+00 0.45725698 0.51970680 243.00 1.53323050e+00 3.84779674e-01 1.58077549e+00 0.24588208 0.44537066 243.25 1.53147682e+00 9.23322951e-02 1.53425764e+00 0.06021682 0.36561279 243.50 8.24453238e-01 -5.62506240e-01 9.98066337e-01 -0.59873267 0.08421525 243.75 5.56943493e-01 -2.79152208e-01 6.22986364e-01 -0.46462455 0.02223708 244.00 -8.41932875e-01 5.14448748e-01 9.86665333e-01 2.59310014 0.03519825 244.25 -1.27017532e+00 1.04690162e+00 1.64600983e+00 2.45225797 0.11285288 244.50 -7.04149881e-01 1.49862357e+00 1.65580786e+00 2.01004615 0.13859058 244.75 -7.17421708e-01 1.18376188e+00 1.38419150e+00 2.11565423 0.11278000 245.00 -6.02165133e-01 1.59870616e+00 1.70835132e+00 1.93101961 0.21944276 245.25 -7.42609776e-01 1.43498317e+00 1.61574936e+00 2.04834901 0.19411774 245.50 -6.70318452e-01 2.02726585e+00 2.13521279e+00 1.89013127 0.36233171 245.75 -8.32065677e-01 2.16532851e+00 2.31969413e+00 1.93766719 0.42337681 246.00 -5.62640749e-01 2.96952729e+00 3.02235950e+00 1.75804812 0.56359618 246.25 -1.94865008e-01 2.75909553e+00 2.76596827e+00 1.64130566 0.50433310 246.50 2.49420604e-01 2.84145521e+00 2.85238117e+00 1.48324156 0.46766152 246.75 5.85479641e-01 2.64781086e+00 2.71176856e+00 1.35317953 0.46917003 247.00 1.43697468e+00 2.54202594e+00 2.92006714e+00 1.05629212 0.57517007 247.25 1.47495336e+00 2.39951635e+00 2.81658768e+00 1.01964694 0.61409957 247.50 1.72535202e+00 2.29980069e+00 2.87505180e+00 0.92715567 0.73098475 247.75 1.62520058e+00 1.87296591e+00 2.47977383e+00 0.85610728 0.57596159 248.00 1.75992581e+00 1.26441401e+00 2.16704445e+00 0.62299973 0.55827970 248.25 1.85535430e+00 1.26504044e+00 2.24558831e+00 0.59842851 0.60200240 248.50 1.92924083e+00 1.05838011e+00 2.20048600e+00 0.50176716 0.63717336 248.75 1.84986712e+00 8.39923521e-01 2.03162002e+00 0.42621292 0.49175103 249.00 1.54384126e+00 4.22161652e-01 1.60052063e+00 0.26692357 0.41276762 249.25 1.56152082e+00 5.95892622e-01 1.67135732e+00 0.36455348 0.34773598 249.50 1.55562960e+00 6.58019004e-01 1.68907444e+00 0.40016869 0.32226045 249.75 1.66865115e+00 8.79969028e-01 1.88646286e+00 0.48529019 0.17647460 250.00 1.90016639e+00 2.50124561e+00 3.14115614e+00 0.92112365 0.22518317 250.25 2.27014208e+00 2.04517747e+00 3.05553530e+00 0.73331369 0.22538511 250.50 2.26571219e+00 6.39332909e-01 2.35418740e+00 0.27502672 0.22864511 250.75 1.82627685e+00 5.69868566e-01 1.91312240e+00 0.30246431 0.18355814 251.00 1.50879740e+00 4.17987250e-01 1.56562541e+00 0.27025565 0.15445680 251.25 1.39625461e+00 4.87445725e-01 1.47889494e+00 0.33588127 0.14478168 251.50 1.09125428e+00 2.59866320e-01 1.12176932e+00 0.23378123 0.14074487 251.75 1.26886274e+00 6.47896187e-01 1.42470422e+00 0.47210090 0.20491658 252.00 1.48445132e+00 5.74788912e-01 1.59184736e+00 0.36942891 0.31618440 252.25 1.70943548e+00 5.39318417e-02 1.71028603e+00 0.03153904 0.32888223 252.50 1.97162528e+00 -1.31835827e-01 1.97602807e+00 -0.06676718 0.47496989 252.75 1.85972670e+00 3.64301506e-02 1.86008348e+00 0.01958648 0.41175981 253.00 2.09377934e+00 -2.33678582e-01 2.10677897e+00 -0.11114616 0.52166869 253.25 1.86269765e+00 -3.88020341e-01 1.90268292e+00 -0.20537395 0.45187728 253.50 2.21737050e+00 -7.59405531e-01 2.34380646e+00 -0.32996004 0.56144708 253.75 2.25043551e+00 -1.61704968e+00 2.77115674e+00 -0.62306722 0.60174859 254.00 2.25483873e+00 -2.20908119e+00 3.15663387e+00 -0.77514799 0.62175461 254.25 9.29805318e-01 -2.73051810e+00 2.88448730e+00 -1.24258873 0.51195210 254.50 4.50207658e-01 -2.44975590e+00 2.49078118e+00 -1.38904779 0.48660884 254.75 1.67134846e-01 -3.24778875e+00 3.25208638e+00 -1.51938056 0.59653424 255.00 4.92848212e-02 -3.46485347e+00 3.46520397e+00 -1.55657307 0.61995653 255.25 -1.23333227e+00 -3.03311148e+00 3.27427454e+00 -1.95699894 0.52771658 255.50 -2.14724803e+00 -2.21276073e+00 3.08333977e+00 -2.34116980 0.50571611 255.75 -2.73470312e+00 -7.49013193e-01 2.83542270e+00 -2.87425687 0.55326781 256.00 -2.52643360e+00 -2.43961524e-01 2.53818517e+00 -3.04532752 0.59789703 256.25 -2.31156115e+00 7.56830457e-03 2.31157354e+00 3.13831856 0.56691476 256.50 -2.07624958e+00 3.76117413e-01 2.11004186e+00 2.96238379 0.48849605 256.75 -1.52086628e+00 5.84713315e-01 1.62939373e+00 2.77455358 0.37362607 257.00 -1.16708645e+00 6.80847682e-01 1.35116407e+00 2.61348800 0.28351616 257.25 -9.33643658e-01 8.42473248e-01 1.25755781e+00 2.40748079 0.29476600 257.50 -7.74699888e-01 8.17592742e-01 1.12632935e+00 2.32926321 0.24913070 257.75 -7.40605863e-01 5.86082778e-01 9.44452257e-01 2.47214481 0.24976228 258.00 -7.36764080e-01 6.56588456e-01 9.86878772e-01 2.41367263 0.23511870 258.25 -6.91238391e-01 5.46590678e-01 8.81233160e-01 2.47252287 0.20776470 258.50 -4.96786278e-01 3.66173904e-01 6.17154708e-01 2.50640826 0.10553445 258.75 -4.06880420e-01 3.41783388e-02 4.08313403e-01 3.05778845 0.06703688 259.00 -4.63287255e-01 2.16014824e-01 5.11172657e-01 2.70529504 0.08074336 259.25 -5.72231453e-01 2.49923036e-01 6.24428026e-01 2.72981050 0.16285228 259.50 -5.75496210e-01 8.80204676e-02 5.82188536e-01 2.98982173 0.12227764 259.75 -4.85634488e-01 4.63288276e-02 4.87839334e-01 3.04648193 0.15032555 260.00 -4.63985689e-01 1.03155463e-01 4.75314390e-01 2.92282609 0.13376501 260.25 -4.40819508e-01 5.36370821e-03 4.40852138e-01 3.12942567 0.13015546 260.50 -3.54356423e-01 4.86211870e-02 3.57676522e-01 3.00523428 0.06052262 260.75 -3.28334454e-01 -8.42154989e-02 3.38962777e-01 -2.89051230 0.07302909 261.00 -3.41579497e-01 -2.17130278e-01 4.04749441e-01 -2.57536055 0.06794549 261.25 -5.31214781e-01 -4.54130608e-01 6.98873202e-01 -2.43426609 0.21024522 261.50 -6.66243173e-01 -7.70758109e-01 1.01879734e+00 -2.28359105 0.27391603 261.75 -9.47987949e-01 -8.97056862e-01 1.30514067e+00 -2.38379174 0.42845705 262.00 -1.04108791e+00 -8.87671526e-01 1.36814647e+00 -2.43556886 0.29373096 262.25 -1.01485824e+00 -9.72131751e-01 1.40533888e+00 -2.37769430 0.28349524 262.50 -7.92775894e-01 -1.05018981e+00 1.31582379e+00 -2.21741855 0.20896937 262.75 -6.21819231e-01 -1.18603279e+00 1.33915381e+00 -2.05368267 0.22862342 263.00 -5.11112994e-01 -1.32644228e+00 1.42150822e+00 -1.93858925 0.18775010 263.25 -5.70562932e-01 -1.46556081e+00 1.57270803e+00 -1.94205658 0.20865868 263.50 1.11263523e-02 -1.71628424e+00 1.71632030e+00 -1.56431360 0.16472110 263.75 3.46337108e-01 -1.86000041e+00 1.89197012e+00 -1.38670191 0.22175327 264.00 8.35716930e-01 -1.83331356e+00 2.01481051e+00 -1.14308777 0.32572926 264.25 5.28009521e-01 -1.94779351e+00 2.01809158e+00 -1.30607736 0.43554379 264.50 6.06853654e-01 -1.71388172e+00 1.81814793e+00 -1.23049015 0.37409308 264.75 9.82139977e-01 -1.59671893e+00 1.87459603e+00 -1.01934864 0.32923852 265.00 1.98449680e+00 -8.68194538e-01 2.16610002e+00 -0.41240079 0.31696581 265.25 2.22699328e+00 -7.10698663e-01 2.33764661e+00 -0.30891286 0.34143404 265.50 2.05377848e+00 -9.79438399e-01 2.27536934e+00 -0.44499403 0.35712640 265.75 1.94024981e+00 -1.24263394e+00 2.30406346e+00 -0.56963271 0.36554656 266.00 7.39970360e-01 -7.43559140e-01 1.04901684e+00 -0.78781724 0.13584184 266.25 7.60192605e-01 -7.25973701e-01 1.05115680e+00 -0.76237728 0.15609159 266.50 4.79591450e-01 -8.58948597e-01 9.83768596e-01 -1.06156720 0.13367007 266.75 5.38705888e-01 -5.74713107e-01 7.87717709e-01 -0.81772622 0.07654326 267.00 3.17758514e-01 -4.28774627e-01 5.33683571e-01 -0.93302517 0.03640231 267.25 4.35454360e-01 -2.42829621e-01 4.98584721e-01 -0.50869492 0.03435261 267.50 5.30265918e-01 -4.14559497e-01 6.73083590e-01 -0.66354164 0.06135628 267.75 5.14239093e-01 -3.48283435e-01 6.21082278e-01 -0.59531379 0.04972397 268.00 2.08616557e-01 -2.61691525e-01 3.34668974e-01 -0.89777421 0.01531784 268.25 4.51281401e-01 -2.10393577e-01 4.97916017e-01 -0.43625514 0.02407712 268.50 6.30586477e-01 -8.31585036e-02 6.36046100e-01 -0.13111826 0.05649468 268.75 6.02615308e-01 -1.08974686e-01 6.12389330e-01 -0.17890282 0.05531589 269.00 6.98971611e-01 5.20169828e-02 7.00904472e-01 0.07428238 0.09752663 269.25 9.12449235e-01 8.08523469e-02 9.16024404e-01 0.08837941 0.12572265 269.50 1.05095942e+00 1.65198830e-01 1.06386388e+00 0.15591283 0.16937573 269.75 1.17985238e+00 1.80900393e-01 1.19364006e+00 0.15213979 0.15211116 270.00 1.39293361e+00 9.29317261e-02 1.39603021e+00 0.06661783 0.21619808 270.25 1.03795209e+00 -1.95862281e-01 1.05627012e+00 -0.18650761 0.10874464 270.50 7.71785076e-01 -3.37712581e-01 8.42438123e-01 -0.41247201 0.09212537 270.75 1.08543427e+00 6.09693934e-02 1.08714526e+00 0.05611154 0.10276540 271.00 1.64389125e+00 7.48401495e-01 1.80623455e+00 0.42722132 0.26261459 271.25 1.87341989e+00 9.82431043e-01 2.11538952e+00 0.48298057 0.22186243 271.50 1.90072625e+00 5.16902890e-01 1.96975858e+00 0.26552863 0.20615038 271.75 1.66472891e+00 1.39227763e-01 1.67054084e+00 0.08343971 0.11290498 272.00 1.85762192e+00 2.49256370e-01 1.87426997e+00 0.13338367 0.14983596 272.25 2.53770363e+00 5.90911770e-01 2.60559330e+00 0.22877630 0.17648486 272.50 3.22905580e+00 5.26664884e-01 3.27172389e+00 0.16167819 0.28137367 272.75 2.63332582e+00 4.11888099e-01 2.66534363e+00 0.15515649 0.19516910 273.00 2.37208189e+00 4.30135185e-01 2.41076519e+00 0.17938317 0.14583831 273.25 2.54928628e+00 5.74839421e-01 2.61329311e+00 0.22178110 0.12950500 273.50 2.76178123e+00 5.70395256e-01 2.82006849e+00 0.20366804 0.14505599 273.75 2.22952111e+00 1.94705819e+00 2.96003378e+00 0.71787079 0.17946531 274.00 2.20504372e+00 2.16923632e+00 3.09318670e+00 0.77721245 0.21043814 274.25 1.58176732e+00 2.50051229e+00 2.95880881e+00 1.00676671 0.20630490 274.50 1.78289142e+00 2.38312642e+00 2.97623812e+00 0.92849227 0.20802136 274.75 1.58809076e+00 1.62953819e+00 2.27539601e+00 0.79827881 0.17796909 275.00 1.16904220e+00 1.54037992e+00 1.93376057e+00 0.92160379 0.18549623 275.25 1.42910022e+00 1.79444377e+00 2.29398254e+00 0.89825259 0.29032397 275.50 1.30207685e+00 1.39305864e+00 1.90683416e+00 0.81914313 0.28483731 275.75 7.77309022e-01 8.91723647e-01 1.18295409e+00 0.85384254 0.16342695 276.00 6.57652576e-01 6.00461462e-01 8.90539655e-01 0.73997162 0.09887187 276.25 6.04046090e-01 1.21235511e+00 1.35450234e+00 1.10855620 0.18566266 276.50 5.74031183e-01 1.02158184e+00 1.17181110e+00 1.05885953 0.19964288 276.75 5.51060028e-01 8.36511955e-01 1.00170824e+00 0.98828805 0.23404694 277.00 4.39987393e-01 9.57447278e-01 1.05370499e+00 1.14003553 0.24443291 277.25 7.65080785e-01 6.67258186e-01 1.01517589e+00 0.71720835 0.22945677 277.50 7.80987004e-01 5.76455044e-01 9.70691051e-01 0.63584858 0.18405076 277.75 8.02474971e-01 8.44750058e-01 1.16514752e+00 0.81105696 0.27820991 278.00 8.03132257e-01 8.36767474e-01 1.15982810e+00 0.80590582 0.28255504 278.25 8.87515194e-01 5.23785724e-01 1.03055068e+00 0.53316094 0.33606893 278.50 8.30854728e-01 4.04491889e-01 9.24085098e-01 0.45306290 0.24222312 278.75 9.43371753e-01 2.17803765e-01 9.68188383e-01 0.22690210 0.31113571 279.00 9.12720723e-01 2.54601210e-01 9.47565773e-01 0.27203250 0.28227196 279.25 5.89172736e-01 2.54137024e-01 6.41646429e-01 0.40723306 0.21591722 279.50 4.91400766e-01 2.64264257e-01 5.57951889e-01 0.49341090 0.13326356 279.75 4.68350328e-01 3.46146205e-01 5.82382370e-01 0.63647262 0.20098997 280.00 5.26415639e-01 4.10068331e-01 6.67285142e-01 0.66179308 0.19475022 280.25 5.63003580e-01 5.90421432e-01 8.15825041e-01 0.80916450 0.30754339 280.50 5.77345994e-01 6.78698862e-01 8.91044635e-01 0.86591579 0.24443918 280.75 8.64081996e-01 6.67698570e-01 1.09199775e+00 0.65788777 0.30219622 281.00 1.42479435e+00 3.76008703e-01 1.47357439e+00 0.25802122 0.33257823 281.25 1.81718519e+00 -8.04367292e-02 1.81896457e+00 -0.04423559 0.44625515 281.50 1.44446365e+00 -4.36263715e-01 1.50890731e+00 -0.29331329 0.28828471 281.75 9.80204334e-01 -6.53724077e-01 1.17820020e+00 -0.58818235 0.21908812 282.00 5.75534969e-01 -7.14003481e-01 9.17083132e-01 -0.89236665 0.11364331 282.25 3.16914996e-01 -9.38125098e-01 9.90208975e-01 -1.24501554 0.18638908 282.50 2.49473992e-01 -1.08599250e+00 1.11427868e+00 -1.34499407 0.26270553 282.75 8.08448116e-02 -1.22489662e+00 1.22756165e+00 -1.50489058 0.38257017 283.00 -5.39287004e-02 -1.14109541e+00 1.14236904e+00 -1.61802165 0.37088368 283.25 -2.22409965e-01 -1.15874910e+00 1.17990070e+00 -1.76042973 0.51217545 283.50 -3.19746831e-01 -9.16974188e-01 9.71122905e-01 -1.90631054 0.36630870 283.75 -3.95262849e-01 -8.32845200e-01 9.21880604e-01 -2.01391287 0.38964665 284.00 -4.85253064e-01 -8.39235916e-01 9.69426355e-01 -2.09503829 0.34077692 284.25 -5.80189277e-01 -9.25683882e-01 1.09247895e+00 -2.13066619 0.47369350 284.50 -8.98177021e-01 -6.44185790e-01 1.10530416e+00 -2.51940637 0.45975250 284.75 -9.60369261e-01 -3.48602741e-01 1.02168145e+00 -2.79339421 0.48890456 285.00 -1.11769125e+00 -9.20575192e-02 1.12147596e+00 -3.05941415 0.44656888 285.25 -1.03514889e+00 -3.10575235e-02 1.03561469e+00 -3.11159870 0.45098466 285.50 -1.39549245e+00 8.43363059e-02 1.39803855e+00 3.08123127 0.67954551 285.75 -1.44112426e+00 1.06309117e-01 1.44504006e+00 3.06795785 0.71289747 286.00 -1.30358844e+00 3.55558982e-01 1.35120872e+00 2.87531571 0.70190399 286.25 -1.29831422e+00 4.98390011e-01 1.39068775e+00 2.77506420 0.72566428 286.50 -1.41558791e+00 8.46044459e-01 1.64914534e+00 2.60289334 0.72226020 286.75 -1.53268128e+00 1.02325341e+00 1.84286718e+00 2.55292820 0.77208663 287.00 -1.30917064e+00 1.14076227e+00 1.73645222e+00 2.42482652 0.70734077 287.25 -1.21360432e+00 1.49822429e+00 1.92808492e+00 2.25162234 0.72998008 287.50 -9.65659920e-01 2.11564753e+00 2.32561036e+00 1.99899040 0.80899923 287.75 -5.53056983e-01 2.13078891e+00 2.20139351e+00 1.82474755 0.79831469 288.00 -9.09006508e-02 1.97905052e+00 1.98113702e+00 1.61669551 0.80876759 288.25 9.83789146e-02 1.91995069e+00 1.92246952e+00 1.51960077 0.78557790 288.50 1.00388292e-01 1.72868367e+00 1.73159610e+00 1.51278937 0.81367008 288.75 1.55068517e-01 1.79627774e+00 1.80295867e+00 1.48468213 0.79954845 289.00 3.78450821e-01 1.93525548e+00 1.97191247e+00 1.37767747 0.82720874 289.25 4.99801521e-01 1.87735590e+00 1.94274721e+00 1.31060511 0.81298013 289.50 4.73610917e-01 1.81494574e+00 1.87572262e+00 1.31553820 0.84803153 289.75 6.60472391e-01 1.74251421e+00 1.86348586e+00 1.20849357 0.78484102 290.00 5.86627880e-01 1.65893936e+00 1.75960565e+00 1.23090356 0.80906548 290.25 6.62545822e-01 1.69453873e+00 1.81945829e+00 1.19808220 0.79614265 290.50 7.10007968e-01 1.62269182e+00 1.77122558e+00 1.15834435 0.87062241 290.75 7.52986509e-01 1.59132407e+00 1.76048316e+00 1.12883205 0.78162460 291.00 6.90289492e-01 1.70149422e+00 1.83618685e+00 1.18538922 0.79305745 291.25 6.74845727e-01 1.65004370e+00 1.78271169e+00 1.18256698 0.80586114 291.50 6.98217764e-01 1.57691653e+00 1.72457931e+00 1.15396770 0.85015058 291.75 7.41203906e-01 1.69020233e+00 1.84558044e+00 1.15752195 0.83271137 292.00 8.10946273e-01 1.86253089e+00 2.03141703e+00 1.16014972 0.86464009 292.25 8.35744865e-01 2.15073440e+00 2.30740719e+00 1.20016833 0.80298574 292.50 8.34069370e-01 2.44293603e+00 2.58139656e+00 1.24178473 0.87073777 292.75 1.12555441e+00 2.72767972e+00 2.95078115e+00 1.17943965 0.83897508 293.00 1.53311250e+00 3.13938700e+00 3.49373506e+00 1.11651391 0.86858575 293.25 2.05038911e+00 3.30834000e+00 3.89219849e+00 1.01597129 0.80748805 293.50 2.81326597e+00 3.45367127e+00 4.45447086e+00 0.88723260 0.84033183 293.75 3.41608001e+00 3.25414045e+00 4.71794793e+00 0.76112494 0.84621034 294.00 3.69516832e+00 3.26792703e+00 4.93291151e+00 0.72411704 0.86201008 294.25 5.22713645e+00 2.95801278e+00 6.00606319e+00 0.51496506 0.86839313 294.50 6.03199711e+00 2.46919530e+00 6.51781517e+00 0.38854026 0.87839453 294.75 6.64340055e+00 9.37002334e-01 6.70915376e+00 0.14011833 0.79169130 295.00 7.39253911e+00 -1.07280218e+00 7.46997584e+00 -0.14411354 0.82961901 295.25 5.97837036e+00 -3.19008586e+00 6.77624970e+00 -0.49016849 0.84361949 295.50 5.15203382e+00 -3.81978943e+00 6.41359834e+00 -0.63798331 0.85821136 295.75 3.23555746e+00 -4.32106126e+00 5.39818511e+00 -0.92807155 0.71041156 296.00 1.73793016e+00 -4.38683935e+00 4.71855494e+00 -1.19359681 0.64441926 296.25 2.27217380e-01 -3.35651331e+00 3.36419520e+00 -1.50320498 0.63985863 296.50 -4.10943197e-01 -2.93274315e+00 2.96139438e+00 -1.71001238 0.64027266 296.75 -5.67222942e-01 -1.58500909e+00 1.68344756e+00 -1.91446262 0.54222890 297.00 -4.82529743e-01 -1.23273319e+00 1.32380741e+00 -1.94389371 0.53539756 297.25 -3.40056360e-01 -7.96860603e-01 8.66386259e-01 -1.97414416 0.41737750 297.50 -2.56122718e-01 -5.45070401e-01 6.02246285e-01 -2.01006649 0.26696957 297.75 -9.25509981e-02 -4.08872362e-01 4.19216288e-01 -1.79340172 0.20347875 298.00 1.85696532e-02 -2.57072971e-01 2.57742788e-01 -1.49868662 0.10212320 298.25 2.38481806e-01 -3.04291565e-01 3.86609529e-01 -0.90605642 0.30873063 298.50 2.37268096e-01 -2.51976014e-01 3.46104119e-01 -0.81545165 0.21075171 298.75 1.27211128e-01 -8.00395641e-02 1.50296383e-01 -0.56160439 0.06462990 299.00 1.40877642e-01 -1.70885323e-02 1.41910282e-01 -0.12071079 0.05964762 299.25 1.22850548e-01 5.32329952e-02 1.33888046e-01 0.40889246 0.07311721 299.50 1.32112509e-01 9.36209852e-02 1.61921598e-01 0.61650503 0.08606037 299.75 6.39779870e-02 1.58900868e-01 1.71297019e-01 1.18802623 0.09613621 300.00 6.83709547e-02 2.25180829e-01 2.35331666e-01 1.27601544 0.10761871 300.25 1.56700634e-01 3.75467530e-01 4.06854955e-01 1.17542478 0.27678017 300.50 1.43311224e-01 3.97614460e-01 4.22652772e-01 1.22486226 0.24083407 300.75 -8.68874276e-02 3.80290896e-01 3.90090491e-01 1.79541701 0.22641154 301.00 -9.21802463e-02 4.69732498e-01 4.78691777e-01 1.76457378 0.32391479 301.25 -1.67274233e-01 5.78439445e-01 6.02140233e-01 1.85229897 0.51689346 301.50 -1.70797292e-01 6.19626956e-01 6.42735777e-01 1.83976242 0.42196460 301.75 -2.90546142e-01 6.27213770e-01 6.91241039e-01 2.00460020 0.52585348 302.00 -4.78997303e-01 8.06133244e-01 9.37704230e-01 2.10693372 0.58828257 302.25 -6.52396238e-01 1.07137029e+00 1.25437440e+00 2.11776072 0.78294454 302.50 -6.30794693e-01 1.20184081e+00 1.35732210e+00 2.05413130 0.79161593 302.75 -6.61137995e-01 1.33448101e+00 1.48927600e+00 2.03077889 0.84426741 303.00 -7.83565264e-01 1.52653961e+00 1.71589559e+00 2.04502334 0.78014785 303.25 -8.16704524e-01 1.77988261e+00 1.95831264e+00 2.00098800 0.80727153 303.50 -5.56120994e-01 1.91915324e+00 1.99810404e+00 1.85284540 0.79176272 303.75 -6.38025980e-01 1.88105747e+00 1.98631678e+00 1.89780387 0.86763638 304.00 -9.61842854e-01 1.99651066e+00 2.21612195e+00 2.01974733 0.85031363 304.25 -1.07100015e+00 2.23745059e+00 2.48056978e+00 2.01723467 0.89781155 304.50 -6.95585775e-01 2.58472977e+00 2.67668966e+00 1.83368175 0.86719148 304.75 -4.99604151e-01 2.71270232e+00 2.75832525e+00 1.75292750 0.88701658 305.00 -6.20104542e-01 2.77607467e+00 2.84448945e+00 1.79056314 0.89336919 305.25 -5.91999756e-01 2.81219987e+00 2.87383573e+00 1.77827814 0.91221453 305.50 -5.42471043e-01 2.66347494e+00 2.71815629e+00 1.77171863 0.89115533 305.75 -6.04700486e-01 2.61545604e+00 2.68445022e+00 1.79800668 0.88212926 306.00 -8.22734978e-01 2.68589696e+00 2.80908086e+00 1.86803810 0.90003918 306.25 -8.47077569e-01 2.82677768e+00 2.95096805e+00 1.86194291 0.91877483 306.50 -1.11008930e+00 3.00998284e+00 3.20816068e+00 1.92412256 0.91018018 306.75 -1.20289097e+00 2.99085942e+00 3.22369148e+00 1.95318841 0.89651778 307.00 -1.47391393e+00 2.76216835e+00 3.13081399e+00 2.06096713 0.81227743 307.25 -1.60076027e+00 2.72970560e+00 3.16444720e+00 2.10117241 0.82677122 307.50 -1.99478588e+00 2.79759147e+00 3.43594074e+00 2.19021839 0.77688765 307.75 -2.38327158e+00 2.94112459e+00 3.78552470e+00 2.25180235 0.73258798 308.00 -3.97626324e+00 2.07437371e+00 4.48482950e+00 2.66074460 0.49440795 308.25 -4.64802423e+00 1.00334762e+00 4.75508524e+00 2.92898948 0.35076792 308.50 1.92750634e+00 -1.05250218e+00 2.19614243e+00 -0.49980047 0.05390948 308.75 2.99165650e+00 -1.69122231e+00 3.43660319e+00 -0.51452377 0.18407732 309.00 1.87957438e+00 -1.72249290e+00 2.54946694e+00 -0.74181707 0.24523676 309.25 1.55083983e+00 -1.43596096e+00 2.11354869e+00 -0.74695493 0.27520749 309.50 3.50632285e-01 -1.30404174e+00 1.35035842e+00 -1.30812758 0.24180949 309.75 -6.59443457e-01 -9.07979594e-01 1.12218208e+00 -2.19894015 0.16684652 310.00 -1.88586089e+00 3.79776216e-01 1.92372068e+00 2.94286973 0.45347243 310.25 -2.61777070e+00 1.18581810e+00 2.87382811e+00 2.71625688 0.60747310 310.50 -2.94260775e+00 2.73109097e+00 4.01469778e+00 2.39345746 0.81286691 310.75 -2.69500529e+00 3.40410830e+00 4.34177462e+00 2.24045084 0.82373636 311.00 -1.79946223e+00 3.99458166e+00 4.38118101e+00 1.99404583 0.86731443 311.25 -1.34167778e+00 4.17952186e+00 4.38959021e+00 1.88141724 0.88040653 311.50 -7.62037958e-01 4.34034227e+00 4.40673040e+00 1.74459591 0.93648722 311.75 -5.21321182e-01 4.39480570e+00 4.42561780e+00 1.68886671 0.94367744 312.00 -1.08253616e-01 4.40057435e+00 4.40190566e+00 1.59539125 0.95010318 312.25 3.20822574e-01 4.18161423e+00 4.19390328e+00 1.49422415 0.90122354 312.50 6.20624681e-01 3.54709685e+00 3.60098196e+00 1.39758274 0.92304478 312.75 4.47496307e-01 3.39647241e+00 3.42582512e+00 1.43979759 0.92755437 313.00 2.02197531e-01 3.43652409e+00 3.44246738e+00 1.51202628 0.95407102 313.25 2.28966739e-01 3.33344059e+00 3.34129495e+00 1.50221623 0.94981950 313.50 2.15178535e-01 3.36905250e+00 3.37591714e+00 1.50701381 0.95814347 313.75 1.86654985e-01 3.60633179e+00 3.61115897e+00 1.51908490 0.95500190 314.00 1.28557045e-01 3.74351127e+00 3.74571803e+00 1.53646852 0.96268671 314.25 2.27608175e-01 3.92612090e+00 3.93271290e+00 1.51288835 0.92927985 314.50 3.92019586e-01 4.06142492e+00 4.08030045e+00 1.47457175 0.90173768 314.75 1.10573100e+00 3.95758832e+00 4.10915397e+00 1.29834859 0.68582829 315.00 2.85133079e+00 3.88913599e+00 4.82239215e+00 0.93816493 0.62914778 315.25 4.11005056e+00 2.33697483e+00 4.72799820e+00 0.51701122 0.73082352 315.50 4.00054303e+00 1.30260864e+00 4.20727154e+00 0.31478168 0.80028933 315.75 3.27629497e+00 5.24936957e-01 3.31808191e+00 0.15887243 0.78694467 316.00 2.66146248e+00 2.64327516e-01 2.67455633e+00 0.09899201 0.81380216 316.25 2.34685109e+00 -9.92145910e-02 2.34894734e+00 -0.04225046 0.90076763 316.50 2.10302629e+00 -2.21347178e-01 2.11464280e+00 -0.10486565 0.88091599 316.75 1.38590168e+00 -4.78163418e-01 1.46607084e+00 -0.33223118 0.82670175 317.00 1.09892177e+00 -4.13534343e-01 1.17415489e+00 -0.35991794 0.79609091 317.25 7.71353997e-01 -2.81085888e-01 8.20972755e-01 -0.34945043 0.74101991 317.50 6.85628126e-01 -2.47486936e-01 7.28927781e-01 -0.34640854 0.68297580 317.75 4.03950757e-01 -1.02670363e-01 4.16794215e-01 -0.24889531 0.35794385 318.00 3.22026618e-01 -5.95794582e-02 3.27491762e-01 -0.18294538 0.23979582 318.25 2.64312213e-01 -2.02040380e-03 2.64319935e-01 -0.00764386 0.16970882 318.50 1.62187826e-01 9.03655297e-04 1.62190343e-01 0.00557160 0.05906037 318.75 1.71825459e-01 1.13943035e-01 2.06172267e-01 0.58555183 0.11061889 319.00 1.23551342e-01 5.73397826e-02 1.36208608e-01 0.43451479 0.04408235 319.25 -2.10501004e-02 -5.05871669e-02 5.47920449e-02 -1.96511766 0.00743145 319.50 -9.00243723e-02 2.55677241e-02 9.35847003e-02 2.86487037 0.01618907 319.75 -9.15331595e-02 2.11962686e-02 9.39553144e-02 2.91403433 0.01547171 320.00 -2.08656633e-01 3.47422984e-02 2.11529237e-01 2.97660162 0.06151123 320.25 -3.05099784e-01 -9.29904987e-03 3.05241462e-01 -3.11112337 0.12454520 320.50 -3.36761167e-01 8.38297470e-03 3.36865489e-01 3.11670486 0.10990858 320.75 -3.79838841e-01 -8.88091936e-02 3.90082835e-01 -2.91191102 0.14254320 321.00 -3.11854434e-01 -2.14086979e-01 3.78267661e-01 -2.53998705 0.13626371 321.25 -3.36415542e-01 -4.08742524e-01 5.29382535e-01 -2.25943499 0.36709155 321.50 -4.09272210e-01 -3.76172981e-01 5.55886548e-01 -2.39831030 0.33604251 321.75 -5.29350472e-01 -3.27174504e-01 6.22298223e-01 -2.58799380 0.45484594 322.00 -6.45974293e-01 -4.70388806e-01 7.99092245e-01 -2.51219994 0.48376689 322.25 -8.97638728e-01 -5.97014660e-01 1.07804536e+00 -2.55467920 0.59767643 322.50 -1.09721388e+00 -4.93380949e-01 1.20303909e+00 -2.71901563 0.60526602 322.75 -1.33060046e+00 -4.99777764e-01 1.42136392e+00 -2.78229327 0.75749093 323.00 -1.45751192e+00 -5.44710475e-01 1.55597252e+00 -2.78393916 0.66758697 323.25 -1.65166640e+00 -6.68253302e-01 1.78173072e+00 -2.75713274 0.73101517 323.50 -1.86797031e+00 -7.70232183e-01 2.02053723e+00 -2.75049688 0.75606599 323.75 -2.08613751e+00 -7.83682801e-01 2.22848120e+00 -2.78224164 0.83315639 324.00 -2.18331680e+00 -4.18457800e-01 2.22305627e+00 -2.95222757 0.71420501 324.25 -2.45240399e+00 -3.34631805e-01 2.47512904e+00 -3.00597964 0.80387636 324.50 -2.72359428e+00 -4.93659096e-01 2.76797130e+00 -2.96228650 0.79624146 324.75 -3.29702761e+00 -6.96129370e-01 3.36971619e+00 -2.93351032 0.86091508 325.00 -3.94809304e+00 -3.67961875e-01 3.96520297e+00 -3.04866121 0.87660291 325.25 -4.22447006e+00 -2.68733415e-01 4.23300897e+00 -3.07806473 0.88500925 325.50 -5.49606624e+00 1.22833887e-01 5.49743870e+00 3.11924695 0.79845099 325.75 -6.90705200e+00 5.30321320e-01 6.92738103e+00 3.06496331 0.87339296 326.00 -9.06786207e+00 2.66323362e+00 9.45086958e+00 2.85592539 0.90851654 326.25 -9.65392757e+00 4.15855589e+00 1.05115130e+01 2.73485074 0.91022323 326.50 -8.48357010e+00 9.48554002e+00 1.27258175e+01 2.30049149 0.82319151 326.75 -6.16380648e+00 1.29154664e+01 1.43108973e+01 2.01607256 0.83915208 327.00 2.09341774e+00 1.38347246e+01 1.39922122e+01 1.42061941 0.81175443 327.25 5.09532108e+00 1.19365167e+01 1.29785487e+01 1.16734424 0.85246755 327.50 6.27770578e+00 8.10238744e+00 1.02497938e+01 0.91161307 0.81752719 327.75 6.34274875e+00 5.94423362e+00 8.69277718e+00 0.75297560 0.81159118 328.00 6.13279667e+00 3.45879631e+00 7.04091379e+00 0.51351570 0.81451638 328.25 5.82725519e+00 2.42658282e+00 6.31230601e+00 0.39458052 0.81638556 328.50 5.08340357e+00 1.50577252e+00 5.30173017e+00 0.28797929 0.79397843 328.75 4.36781120e+00 9.72411079e-01 4.47474670e+00 0.21905865 0.78936520 329.00 3.83035586e+00 6.39488660e-01 3.88337118e+00 0.16542707 0.75665072 329.25 3.33725245e+00 1.51055556e-01 3.34066935e+00 0.04523258 0.68778752 329.50 2.37080837e+00 -4.79231040e-02 2.37129268e+00 -0.02021107 0.63299154 329.75 2.04838763e+00 -4.13779602e-02 2.04880551e+00 -0.02019751 0.59908621 330.00 1.71778532e+00 1.29128860e-02 1.71783386e+00 0.00751703 0.61268554 330.25 1.56123742e+00 1.23309618e-01 1.56609947e+00 0.07881836 0.55352871 330.50 1.36134100e+00 1.52396302e-01 1.36984450e+00 0.11148158 0.55765764 330.75 1.28088542e+00 5.46427900e-02 1.28205042e+00 0.04263432 0.47037283 331.00 9.15687257e-01 -2.34344469e-01 9.45198647e-01 -0.25054445 0.34009809 331.25 6.08759613e-01 -2.52221753e-01 6.58941636e-01 -0.39279059 0.15791013 331.50 3.22029825e-01 -1.10135985e-01 3.40342686e-01 -0.32953513 0.05327693 331.75 -2.19080386e-01 2.28474284e-01 3.16538645e-01 2.33520818 0.03351691 332.00 -7.72825111e-01 5.85908202e-01 9.69818062e-01 2.49290344 0.34928107 332.25 -7.58052097e-01 7.76390833e-01 1.08509249e+00 2.34424366 0.38088322 332.50 -6.22306398e-01 9.09895919e-01 1.10235014e+00 2.17065640 0.41219685 332.75 -7.42416397e-01 1.20697746e+00 1.41703094e+00 2.12224759 0.42191515 333.00 -1.10977506e+00 1.60854686e+00 1.95423225e+00 2.17472781 0.56217356 333.25 -1.13464818e+00 2.29568836e+00 2.56078339e+00 2.02983484 0.61476368 333.50 -1.38522089e+00 3.08565217e+00 3.38231965e+00 1.99275444 0.76640323 333.75 -1.06940974e+00 3.91398616e+00 4.05745300e+00 1.83751417 0.75522550 334.00 -9.42844541e-01 4.82615716e+00 4.91739248e+00 1.76372769 0.85904267 334.25 3.32179466e-01 6.19681389e+00 6.20571072e+00 1.51724270 0.86381561 334.50 1.52016441e+00 7.04109065e+00 7.20332266e+00 1.35816105 0.93680955 334.75 2.97253770e+00 7.00664935e+00 7.61111789e+00 1.16956513 0.93109569 335.00 4.50115352e+00 7.17389049e+00 8.46906652e+00 1.01044756 0.95442158 335.25 6.20456009e+00 6.91539209e+00 9.29081340e+00 0.83952471 0.94211264 335.50 7.72959622e+00 6.20441851e+00 9.91168334e+00 0.67637502 0.94861299 335.75 9.56086732e+00 3.71723446e+00 1.02580708e+01 0.37081128 0.94710025 336.00 1.03958188e+01 2.21712028e+00 1.06296129e+01 0.21012238 0.96281078 336.25 9.69255950e+00 -3.72091939e-01 9.69969907e+00 -0.03837060 0.93435142 336.50 8.70850861e+00 -1.76691895e+00 8.88595098e+00 -0.20017833 0.96170921 336.75 6.90799248e+00 -2.76623498e+00 7.44126441e+00 -0.38088544 0.93898300 337.00 5.88686691e+00 -2.74880417e+00 6.49700903e+00 -0.43685027 0.96052958 337.25 5.31976215e+00 -2.07767072e+00 5.71109314e+00 -0.37233951 0.97737089 337.50 5.22582498e+00 -2.00350314e+00 5.59671972e+00 -0.36610160 0.98648426 337.75 5.09452630e+00 -2.03313647e+00 5.48523857e+00 -0.37971521 0.98796283 338.00 5.00695779e+00 -2.12983907e+00 5.44112496e+00 -0.40218898 0.99123145 338.25 4.81294757e+00 -2.25367793e+00 5.31446409e+00 -0.43792915 0.99167735 338.50 4.68543696e+00 -2.22733244e+00 5.18790220e+00 -0.44375301 0.99192539 338.75 4.65086041e+00 -2.31300093e+00 5.19427337e+00 -0.46150735 0.99194071 339.00 4.61889177e+00 -2.45341154e+00 5.23004678e+00 -0.48827068 0.99315883 339.25 4.32151869e+00 -2.55928246e+00 5.02249445e+00 -0.53467802 0.99517436 339.50 4.25944250e+00 -2.54066797e+00 4.95962137e+00 -0.53782650 0.99403468 339.75 4.18964873e+00 -2.48072787e+00 4.86900064e+00 -0.53459694 0.99060033 340.00 4.14290309e+00 -2.41479635e+00 4.79529847e+00 -0.52773272 0.98860342 340.25 4.08231523e+00 -2.28343517e+00 4.67753929e+00 -0.50999190 0.98564541 340.50 4.09386685e+00 -2.21670938e+00 4.65548561e+00 -0.49627131 0.98152062 340.75 4.24844087e+00 -2.22360392e+00 4.79517093e+00 -0.48218634 0.98563884 341.00 4.25262845e+00 -2.26428892e+00 4.81786811e+00 -0.48926513 0.97871201 341.25 4.29488787e+00 -2.03189530e+00 4.75127987e+00 -0.44189389 0.95091614 341.50 4.32497694e+00 -2.00128655e+00 4.76556118e+00 -0.43338771 0.93932573 341.75 4.49641153e+00 -1.90010328e+00 4.88140442e+00 -0.39982093 0.94956928 342.00 4.67787372e+00 -1.87508453e+00 5.03968694e+00 -0.38123134 0.93358873 342.25 5.14143190e+00 -1.58791794e+00 5.38105987e+00 -0.29955379 0.94314242 342.50 5.02618836e+00 -1.61162384e+00 5.27824789e+00 -0.31028822 0.91286442 342.75 4.76080640e+00 -1.78530129e+00 5.08454307e+00 -0.35877047 0.92311682 343.00 4.82253721e+00 -1.49155618e+00 5.04793076e+00 -0.29995659 0.89640228 343.25 5.11064318e+00 -1.28715192e+00 5.27024040e+00 -0.24672578 0.90858959 343.50 5.04076762e+00 -6.91976704e-01 5.08804186e+00 -0.13642337 0.90954549 343.75 4.99379062e+00 -2.85617392e-01 5.00195183e+00 -0.05713226 0.95221775 344.00 4.99100373e+00 7.78397486e-02 4.99161069e+00 0.01559475 0.92068389 344.25 5.02444716e+00 4.11344544e-01 5.04125715e+00 0.08168644 0.90999367 344.50 4.77268883e+00 1.17324080e+00 4.91477900e+00 0.24104433 0.85946525 344.75 4.22703397e+00 2.06782502e+00 4.70571105e+00 0.45496271 0.88823162 345.00 3.18282354e+00 3.20351280e+00 4.51584543e+00 0.78863776 0.80837633 345.25 1.81128502e+00 3.93511423e+00 4.33196000e+00 1.13942009 0.74412011 345.50 -1.30356017e+00 5.30947725e+00 5.46715811e+00 1.81155007 0.47633418 345.75 -5.22193447e+00 6.36810154e+00 8.23536987e+00 2.25762254 0.42887763 346.00 3.41578211e+00 5.25424366e+00 6.26694853e+00 0.99435104 0.07979849 346.25 1.45080726e+01 6.34876778e+00 1.58363829e+01 0.41249641 0.37451549 346.50 1.10545871e+01 6.81749935e+00 1.29877709e+01 0.55261738 0.38454226 346.75 9.44542256e+00 6.33063533e+00 1.13707058e+01 0.59046765 0.30352962 347.00 3.99872896e+00 3.97954568e+00 5.64150841e+00 0.78299373 0.11180208 347.25 3.78966932e+00 1.84258493e+00 4.21387147e+00 0.45255697 0.07912739 347.50 5.01465014e+00 1.46689849e-01 5.01679519e+00 0.02924392 0.17618192 347.75 4.06382335e+00 3.85230123e-01 4.08204146e+00 0.09451257 0.19863866 348.00 1.97293599e+00 2.69906233e+00 3.34326396e+00 0.93958550 0.14119400 348.25 1.46640544e+00 4.87634784e+00 5.09206375e+00 1.27868097 0.35183803 348.50 4.59470887e-01 7.33448922e+00 7.34886696e+00 1.50823284 0.68110601 348.75 -4.06781497e-02 9.01576615e+00 9.01585792e+00 1.57530819 0.73495694 349.00 -1.79538104e+00 1.29996518e+01 1.31230462e+01 1.70803806 0.85256182 349.25 -2.76141197e+00 1.42925027e+01 1.45568207e+01 1.76165173 0.84943139 349.50 -5.58355571e+00 1.83677965e+01 1.91977093e+01 1.86590611 0.86449963 349.75 -6.93462175e+00 2.04319398e+01 2.15766805e+01 1.89799785 0.87280063 350.00 -6.15207151e+00 2.47819444e+01 2.55341487e+01 1.81412550 0.88290039 350.25 -4.66595704e+00 2.66051926e+01 2.70112464e+01 1.74440843 0.85894668 350.50 -4.49530531e+00 3.27212632e+01 3.30286063e+01 1.70732346 0.87768814 350.75 -2.69204532e+00 3.68801188e+01 3.69782405e+01 1.64366158 0.88921021 351.00 9.51020677e-01 3.94973672e+01 3.95088149e+01 1.54672290 0.92309979 351.25 5.84410080e+00 3.97755332e+01 4.02025690e+01 1.42491308 0.93246434 351.50 9.59155299e+00 3.99934153e+01 4.11274988e+01 1.33541370 0.96550480 351.75 1.32819144e+01 4.04171699e+01 4.25435879e+01 1.25329322 0.95355808 352.00 2.11263279e+01 4.14114521e+01 4.64890320e+01 1.09905645 0.96142347 352.25 2.49569223e+01 3.78321229e+01 4.53223730e+01 0.98764943 0.94993726 352.50 3.46218373e+01 3.26190737e+01 4.75675897e+01 0.75562207 0.95367706 352.75 3.78110313e+01 2.63368399e+01 4.60793144e+01 0.60839905 0.94405419 353.00 3.73240679e+01 1.76600413e+01 4.12911988e+01 0.44194129 0.94338457 353.25 3.48385183e+01 1.17453109e+01 3.67651287e+01 0.32516884 0.92927297 353.50 3.19191352e+01 5.66155642e+00 3.24173474e+01 0.17554612 0.95268351 353.75 2.63789493e+01 1.88187057e+00 2.64459903e+01 0.07121920 0.92672702 354.00 2.15667383e+01 2.19936347e-01 2.15678598e+01 0.01019759 0.95589714 354.25 1.90139169e+01 2.85122540e-01 1.90160545e+01 0.01499434 0.95426265 354.50 1.65670333e+01 -6.72300863e-02 1.65671697e+01 -0.00405804 0.97078526 354.75 1.49717843e+01 3.33173702e-01 1.49754910e+01 0.02224977 0.95821826 355.00 1.38165397e+01 2.94450648e-01 1.38196769e+01 0.02130824 0.94975586 355.25 1.25822106e+01 -2.47255957e-01 1.25846398e+01 -0.01964870 0.92574176 355.50 1.07060728e+01 -6.98566443e-01 1.07288392e+01 -0.06515719 0.94546471 355.75 9.67170307e+00 7.85152793e-02 9.67202176e+00 0.00811786 0.93783880 356.00 8.71331934e+00 3.19682008e-01 8.71918176e+00 0.03667244 0.95559204 356.25 7.83361829e+00 1.68012471e-01 7.83541981e+00 0.02144433 0.93104475 356.50 7.38963920e+00 2.04747913e-01 7.39247517e+00 0.02770034 0.92948254 356.75 6.73730744e+00 3.06218847e-01 6.74426286e+00 0.04541996 0.92589997 357.00 6.29614167e+00 2.52547666e-01 6.30120467e+00 0.04009001 0.94305001 357.25 5.39863286e+00 3.50161058e-01 5.40997685e+00 0.06477033 0.91734113 357.50 4.88556271e+00 4.11294643e-01 4.90284471e+00 0.08398769 0.92160826 357.75 3.99205462e+00 7.39331145e-01 4.05993974e+00 0.18312578 0.84427886 358.00 3.52987482e+00 8.74135732e-01 3.63649963e+00 0.24275560 0.82751642 358.25 2.62989530e+00 1.24460778e+00 2.90953567e+00 0.44202258 0.70927777 358.50 1.92275531e+00 1.61191377e+00 2.50903447e+00 0.69768304 0.63751612 358.75 1.30225991e+00 2.75030114e+00 3.04303093e+00 1.12857485 0.75885399 359.00 1.25085810e+00 3.40623392e+00 3.62864651e+00 1.21885846 0.79277760 359.25 2.55807350e+00 4.83031791e+00 5.46586783e+00 1.08376024 0.85752674 359.50 3.58417866e+00 5.16572528e+00 6.28737261e+00 0.96421763 0.89367763 359.75 4.80718832e+00 4.50199870e+00 6.58612570e+00 0.75262620 0.91774129 360.00 4.78709142e+00 3.76532972e+00 6.09048046e+00 0.66649129 0.91652731 360.25 3.87892626e+00 3.19443108e+00 5.02498347e+00 0.68892765 0.94456381 360.50 3.42829814e+00 3.15587955e+00 4.65969997e+00 0.74404702 0.94465155 360.75 2.79478981e+00 3.11148646e+00 4.18236752e+00 0.83896722 0.94816839 361.00 2.47803133e+00 3.21902889e+00 4.06236215e+00 0.91473871 0.91718937 361.25 1.57622912e+00 4.22140201e+00 4.50607737e+00 1.21343795 0.92434967 361.50 1.27666077e+00 4.64285590e+00 4.81518157e+00 1.30245507 0.88609786 361.75 9.69807151e-01 6.40251666e+00 6.47554982e+00 1.42046630 0.86513987 362.00 4.48096581e-01 7.25173725e+00 7.26556837e+00 1.50908317 0.80712142 362.25 5.36167136e-01 9.36588655e+00 9.38122093e+00 1.51361193 0.56961695 362.50 4.80062830e+00 5.36148742e+00 7.19663667e+00 0.84053340 0.29070754 362.75 1.05007603e+01 9.88374081e-01 1.05471726e+01 0.09384756 0.71196261 363.00 1.04800360e+01 1.53581877e+00 1.05919731e+01 0.14551132 0.81298493 363.25 1.11189849e+01 1.59124312e+00 1.12322696e+01 0.14214530 0.87445712 363.50 1.10504339e+01 -1.31900756e+00 1.11288756e+01 -0.11880044 0.87551023 363.75 1.03752638e+01 -2.29708497e+00 1.06265092e+01 -0.21788542 0.92134430 364.00 9.89650799e+00 -2.31959477e+00 1.01647130e+01 -0.23022923 0.91092863 364.25 9.86001717e+00 -2.67865979e+00 1.02173948e+01 -0.26526666 0.93933916 364.50 9.37134884e+00 -3.88709955e+00 1.01455272e+01 -0.39318716 0.92087444 364.75 9.39617683e+00 -4.98543384e+00 1.06368552e+01 -0.48781214 0.95707728 365.00 9.03736074e+00 -5.90810843e+00 1.07972049e+01 -0.57900178 0.96137608 365.25 8.69784860e+00 -7.00232521e+00 1.11662495e+01 -0.67782116 0.96247795 365.50 8.31997414e+00 -8.99234259e+00 1.22508855e+01 -0.82421623 0.91765804 365.75 7.34117524e+00 -1.10947027e+01 1.33035815e+01 -0.98625195 0.93691660 366.00 4.08889967e+00 -1.30452311e+01 1.36710334e+01 -1.26705515 0.90631054 366.25 2.31294232e-01 -1.34066375e+01 1.34086325e+01 -1.55354582 0.89568158 366.50 -4.01414526e+00 -1.03530686e+01 1.11040259e+01 -1.94067637 0.87283158 366.75 -5.46788713e+00 -8.58792347e+00 1.01808752e+01 -2.13776130 0.91103115 367.00 -5.48049905e+00 -4.68549410e+00 7.21039006e+00 -2.43423804 0.76711250 367.25 -5.12463149e+00 -2.69520509e+00 5.79016220e+00 -2.65741571 0.81583214 367.50 -3.67405937e+00 -1.44571204e+00 3.94826488e+00 -2.76670940 0.75625642 367.75 -3.27458860e+00 -1.01151932e+00 3.42725865e+00 -2.84199116 0.80127965 368.00 -2.65979969e+00 -1.02490018e+00 2.85043063e+00 -2.77379658 0.71632578 368.25 -2.06072097e+00 -9.64981434e-01 2.27546920e+00 -2.70364666 0.61820192 368.50 -1.54141104e+00 -9.72505257e-01 1.82255712e+00 -2.57874842 0.54083563 368.75 -1.33458247e+00 -9.81012980e-01 1.65635046e+00 -2.50771472 0.47869129 369.00 -1.53770397e+00 -6.25637524e-01 1.66010716e+00 -2.75518244 0.42606015 369.25 -1.23372007e+00 -7.25740468e-01 1.43135056e+00 -2.60985487 0.34477784 369.50 -7.35223342e-01 -1.14608186e+00 1.36163762e+00 -2.14118024 0.42991958 369.75 -8.53608615e-01 -1.30256751e+00 1.55734703e+00 -2.15090777 0.54978054 370.00 -6.38846305e-01 -1.55940531e+00 1.68519125e+00 -1.95961361 0.56681510 370.25 -7.75163609e-01 -1.71423982e+00 1.88135504e+00 -1.99547070 0.63790612 370.50 -1.05605183e+00 -1.87533247e+00 2.15223543e+00 -2.08366256 0.72839146 370.75 -1.25935074e+00 -2.08104750e+00 2.43243150e+00 -2.11499569 0.77418634 371.00 -1.64258417e+00 -2.12697736e+00 2.68739938e+00 -2.22839366 0.83542120 371.25 -1.89258236e+00 -2.07864536e+00 2.81116249e+00 -2.30937596 0.84307591 371.50 -2.50607556e+00 -1.89206838e+00 3.14011743e+00 -2.49490396 0.88964397 371.75 -2.69535000e+00 -1.58944925e+00 3.12909900e+00 -2.60878073 0.88649749 372.00 -3.04199100e+00 -1.20801933e+00 3.27307500e+00 -2.76357608 0.88569705 372.25 -3.11420735e+00 -7.08036109e-01 3.19368166e+00 -2.91803614 0.79674061 372.50 -1.85183010e+00 5.95678667e-01 1.94527833e+00 2.83037533 0.58825551 372.75 -7.90077350e-01 9.46968036e-01 1.23327640e+00 2.26611847 0.33219375 373.00 1.14812775e+00 5.36811528e-01 1.26742414e+00 0.43735542 0.13195263 373.25 1.14309441e+00 -1.66521104e+00 2.01980015e+00 -0.96921813 0.12736922 373.50 -2.46345603e+00 -6.42406002e+00 6.88020078e+00 -1.93697494 0.70666437 373.75 -4.74789165e+00 -6.98441382e+00 8.44538403e+00 -2.16782516 0.82919396 374.00 -6.83242298e+00 -6.00958044e+00 9.09928904e+00 -2.42018133 0.89658716 374.25 -7.79734487e+00 -3.79060078e+00 8.66990435e+00 -2.68909444 0.88834269 374.50 -8.24445012e+00 -1.35452583e+00 8.35498043e+00 -2.97875197 0.94165274 374.75 -7.76101864e+00 -5.16792314e-01 7.77820575e+00 -3.07510260 0.92809542 375.00 -7.35827447e+00 -7.87234871e-02 7.35869558e+00 -3.13089443 0.95270451 375.25 -7.25108041e+00 5.06841659e-01 7.26877263e+00 3.07180738 0.94218752 375.50 -7.10876728e+00 1.40043817e+00 7.24539849e+00 2.94708187 0.94421268 375.75 -6.31014095e+00 1.94611908e+00 6.60342777e+00 2.84243700 0.93587476 376.00 -6.04687608e+00 2.02867550e+00 6.37810588e+00 2.81790101 0.96179905 376.25 -5.72902459e+00 1.84513121e+00 6.01882313e+00 2.83001561 0.92364466 376.50 -5.69402646e+00 1.50645635e+00 5.88993617e+00 2.88295076 0.93729630 376.75 -6.05998500e+00 1.28645428e+00 6.19502888e+00 2.93241134 0.94838774 377.00 -6.43649414e+00 1.30267303e+00 6.56699428e+00 2.94190142 0.95213573 377.25 -6.88513610e+00 1.58172096e+00 7.06448444e+00 2.91578090 0.93877572 377.50 -7.65448099e+00 1.92719794e+00 7.89336247e+00 2.89494521 0.93940696 377.75 -7.91009376e+00 3.59242540e+00 8.68764085e+00 2.71528705 0.94518438 378.00 -7.61829496e+00 4.54399886e+00 8.87053232e+00 2.60378107 0.94708988 378.25 -6.68502440e+00 5.51052672e+00 8.66345520e+00 2.45220382 0.95461163 378.50 -6.34924359e+00 6.05960431e+00 8.77677039e+00 2.37953160 0.95551420 378.75 -5.75675183e+00 6.24601872e+00 8.49428876e+00 2.31545422 0.92788741 379.00 -5.15907247e+00 6.33771696e+00 8.17206737e+00 2.25403196 0.91172934 379.25 -3.75515917e+00 5.66847629e+00 6.79947379e+00 2.15588346 0.90358624 379.50 -3.47625691e+00 5.49094948e+00 6.49883746e+00 2.13519095 0.90562336 379.75 -3.65064294e+00 3.69644327e+00 5.19527543e+00 2.34996076 0.83150120 380.00 -4.19508861e+00 3.22324767e+00 5.29037749e+00 2.48645790 0.81726722 380.25 -5.90796628e+00 4.46474980e+00 7.40527220e+00 2.49444278 0.82384241 380.50 -6.02996094e+00 5.21080287e+00 7.96949782e+00 2.42893978 0.86702957 380.75 -5.86616263e+00 4.95127681e+00 7.67639277e+00 2.44056878 0.89431749 381.00 -6.15940269e+00 4.90287425e+00 7.87251024e+00 2.46929652 0.86932377 381.25 -6.89705273e+00 6.60625725e+00 9.55049586e+00 2.37772629 0.84362392 381.50 -6.66588239e+00 7.88165980e+00 1.03225263e+01 2.27281555 0.88976808 381.75 -4.85217646e+00 9.43889725e+00 1.06130296e+01 2.04562998 0.92158102 382.00 -3.83362651e+00 9.55423313e+00 1.02946619e+01 1.95237897 0.92772203 382.25 -2.29066406e+00 9.23820926e+00 9.51796471e+00 1.81384976 0.93112865 382.50 -2.01308160e+00 8.42272692e+00 8.65995532e+00 1.80540116 0.94334153 382.75 -1.48131916e+00 8.07766384e+00 8.21236626e+00 1.75216570 0.95416201 383.00 -1.12659911e+00 7.35946447e+00 7.44519596e+00 1.72269876 0.94673632 383.25 -1.14856954e+00 6.42350494e+00 6.52538334e+00 1.74773375 0.93759498 383.50 -1.36050659e+00 5.84200565e+00 5.99833379e+00 1.79960159 0.93013455 383.75 -1.45291969e+00 5.49600325e+00 5.68480671e+00 1.82924332 0.89658869 384.00 -1.72208275e+00 4.85955472e+00 5.15566107e+00 1.91135935 0.85360626 384.25 -1.88969609e+00 3.98393303e+00 4.40938473e+00 2.01369728 0.84840174 384.50 -2.27266361e+00 3.23012125e+00 3.94951683e+00 2.18392402 0.75349638 384.75 -2.60255029e+00 2.24245464e+00 3.43538511e+00 2.43038116 0.67250989 385.00 -2.51877896e+00 1.32429843e+00 2.84570093e+00 2.65754221 0.44699941 385.25 -3.05708689e+00 -7.32165571e-02 3.05796352e+00 -3.11764745 0.40408464 385.50 -3.17801945e+00 -1.20636336e+00 3.39928230e+00 -2.77879874 0.37047311 385.75 -3.63474199e+00 -4.79830668e+00 6.01955948e+00 -2.21908345 0.50528630 386.00 -6.20354636e+00 -7.77265266e+00 9.94475323e+00 -2.24439277 0.66252981 386.25 -9.13931622e+00 -9.65029762e+00 1.32911755e+01 -2.32900631 0.76333430 386.50 -8.80328284e+00 -9.64619247e+00 1.30593575e+01 -2.31053878 0.69725059 386.75 -7.02461387e+00 -1.09000121e+01 1.29674772e+01 -2.14326662 0.75362321 387.00 -4.18097403e+00 -1.11286717e+01 1.18881402e+01 -1.93017521 0.76728263 387.25 -1.23974947e+00 -1.08733229e+01 1.09437712e+01 -1.68432360 0.71829159 387.50 2.97944658e+00 -1.05942752e+01 1.10052610e+01 -1.29664579 0.75072052 387.75 3.95555619e+00 -9.92113387e+00 1.06806049e+01 -1.19141113 0.82395452 388.00 5.89584536e+00 -6.73022075e+00 8.94745013e+00 -0.85138578 0.81072456 388.25 7.10886778e+00 -5.42613840e+00 8.94309673e+00 -0.65195354 0.86471862 388.50 7.48592660e+00 -3.65858635e+00 8.33212765e+00 -0.45458989 0.90019816 388.75 7.51863602e+00 -3.11928971e+00 8.14001571e+00 -0.39326302 0.93010934 389.00 7.45611108e+00 -1.96164369e+00 7.70984036e+00 -0.25726215 0.94973823 389.25 7.42457267e+00 -1.29165837e+00 7.53609054e+00 -0.17224681 0.94923155 389.50 7.44381205e+00 -2.39684127e-01 7.44766986e+00 -0.03218799 0.94636285 389.75 7.46810371e+00 2.89917752e-02 7.46815999e+00 0.00388206 0.95438573 390.00 7.62477064e+00 6.24138369e-01 7.65027294e+00 0.08167458 0.94792431 390.25 7.47251981e+00 8.38548301e-01 7.51942255e+00 0.11175009 0.94578084 390.50 7.92495779e+00 6.83671323e-01 7.95439265e+00 0.08605508 0.96243025 390.75 8.14004872e+00 5.75361282e-01 8.16035745e+00 0.07056542 0.96975351 391.00 8.17811591e+00 4.78197046e-01 8.19208473e+00 0.05840626 0.97103528 391.25 8.35558042e+00 4.26189138e-01 8.36644257e+00 0.05096236 0.97560450 391.50 8.80230605e+00 -4.38762749e-02 8.80241540e+00 -0.00498459 0.97782901 391.75 9.02167184e+00 -7.79382169e-01 9.05527467e+00 -0.08617603 0.96775312 392.00 9.42954148e+00 -2.32820605e+00 9.71271311e+00 -0.24206412 0.97182029 392.25 8.49505733e+00 -3.06640009e+00 9.03154519e+00 -0.34640770 0.95499088 392.50 7.04509291e+00 -3.49378594e+00 7.86383331e+00 -0.46037640 0.96169848 392.75 6.36963014e+00 -3.50550625e+00 7.27054071e+00 -0.50310951 0.94881086 393.00 5.08367710e+00 -3.72265684e+00 6.30094809e+00 -0.63206119 0.96019763 393.25 4.58077222e+00 -3.50512057e+00 5.76795842e+00 -0.65314646 0.94516809 393.50 3.56006592e+00 -3.39866931e+00 4.92189216e+00 -0.76220894 0.91543498 393.75 3.13305553e+00 -3.35924235e+00 4.59353308e+00 -0.82022333 0.91384878 394.00 2.54534826e+00 -3.01179654e+00 3.94331285e+00 -0.86913855 0.91222416 394.25 1.77043981e+00 -3.06042805e+00 3.53562964e+00 -1.04634004 0.81516496 394.50 5.72617857e-01 -2.95037664e+00 3.00543068e+00 -1.37909664 0.75628247 394.75 -6.15455602e-02 -2.81998931e+00 2.82066084e+00 -1.59261761 0.62095085 395.00 -7.56548663e-01 -2.42131796e+00 2.53675906e+00 -1.87363860 0.39363203 395.25 -1.01842577e+00 -1.68529127e+00 1.96911089e+00 -2.11437345 0.21082342 395.50 -1.53782360e+00 -3.48820867e-01 1.57688853e+00 -2.91853934 0.13559734 395.75 -9.57743671e-01 1.08874538e+00 1.45004808e+00 2.29226881 0.06582234 396.00 -1.17376638e+00 1.86259222e+00 2.20158518e+00 2.13311115 0.08261217 396.25 -2.11425640e+00 8.41708298e-01 2.27564342e+00 2.76271596 0.08333512 396.50 -2.07307678e+00 1.81776638e+00 2.75715831e+00 2.42171882 0.09489205 396.75 -2.46910054e+00 6.27278050e+00 6.74123377e+00 1.94579183 0.34103394 397.00 -2.40281277e+00 8.84046750e+00 9.16118851e+00 1.83618233 0.65478819 397.25 -2.53379273e+00 1.10786094e+01 1.13646685e+01 1.79563952 0.77495244 397.50 -1.52310686e+00 1.20356739e+01 1.21316652e+01 1.69667656 0.73128194 397.75 -1.27856488e+00 1.29462911e+01 1.30092729e+01 1.66923628 0.72122894 398.00 -1.99203551e+00 1.44575723e+01 1.45941633e+01 1.70771912 0.73164701 398.25 -1.55249144e+00 1.60291664e+01 1.61041736e+01 1.66734933 0.75607606 398.50 -3.02110220e+00 1.73969681e+01 1.76573372e+01 1.74273843 0.73878027 398.75 -3.92090862e+00 2.12576061e+01 2.16161824e+01 1.75319366 0.64617949 399.00 -4.19360794e+00 2.72456669e+01 2.75665144e+01 1.72351618 0.64364652 399.25 -3.53086456e-01 2.70618505e+01 2.70641538e+01 1.58384297 0.39962989 399.50 -1.09433880e+00 2.56016105e+01 2.56249886e+01 1.61351524 0.31936491 399.75 -9.31704456e+00 1.39141780e+01 1.67454970e+01 2.16083246 0.14932010 400.00 -8.99298760e+00 -1.09651549e+00 9.05959007e+00 -3.02026151 0.06707644 400.25 -8.52615714e+00 -4.95019646e+00 9.85899592e+00 -2.61556794 0.22061869 400.50 -7.51849022e+00 -6.17923100e+00 9.73193665e+00 -2.45365713 0.41607636 400.75 -2.08225999e+00 -5.96824052e+00 6.32105225e+00 -1.90648202 0.50582354 401.00 -1.14986912e-01 -5.06066912e+00 5.06197530e+00 -1.59351410 0.58294270 401.25 1.49041600e+00 -4.64872938e+00 4.88180548e+00 -1.26054270 0.66246170 401.50 2.34636646e+00 -4.56046781e+00 5.12867451e+00 -1.09561512 0.72963543 401.75 2.88423453e+00 -4.43616555e+00 5.29134894e+00 -0.99430592 0.83460068 402.00 2.97624807e+00 -4.43871099e+00 5.34417513e+00 -0.98013022 0.81093704 402.25 3.62649138e+00 -4.48821782e+00 5.77022867e+00 -0.89119480 0.81332070 402.50 4.40728131e+00 -4.69757200e+00 6.44137495e+00 -0.81727044 0.83483594 402.75 3.24203753e+00 -4.97451060e+00 5.93772373e+00 -0.99320594 0.81970573 403.00 2.56849494e+00 -5.03022805e+00 5.64804041e+00 -1.09869518 0.76890508 403.25 1.61128524e+00 -4.54223630e+00 4.81955919e+00 -1.22991046 0.51620371 403.50 9.40295070e-01 -4.50064797e+00 4.59782416e+00 -1.36483455 0.39222157 403.75 2.18689287e-01 -3.59193176e+00 3.59858289e+00 -1.50998791 0.14415450 404.00 -8.10592334e-01 -1.91516833e+00 2.07964652e+00 -1.97118260 0.03313376 404.25 1.99421493e+00 3.77309267e-01 2.02959490e+00 0.18699155 0.02105681 404.50 1.07992155e+00 -2.19775337e+00 2.44874466e+00 -1.11407232 0.04532461 404.75 7.82592715e-01 -1.21770190e+00 1.44749759e+00 -0.99958416 0.02735662 405.00 1.44472745e+00 8.85445568e-01 1.69447670e+00 0.54983681 0.06274930 405.25 3.71277943e+00 2.69451350e+00 4.58749759e+00 0.62779324 0.41504500 405.50 6.20875739e+00 2.77624490e+00 6.80119138e+00 0.42048121 0.73240554 405.75 7.60162397e+00 1.82951641e+00 7.81868386e+00 0.23618257 0.82956099 406.00 9.12347964e+00 5.07201480e-01 9.13756718e+00 0.05553582 0.84149096 406.25 1.05408586e+01 -9.44899775e-01 1.05831251e+01 -0.08940267 0.91376339 406.50 1.15174112e+01 -1.96131302e+00 1.16832149e+01 -0.16867310 0.89886419 406.75 1.21707581e+01 -3.75719794e+00 1.27374993e+01 -0.29942558 0.91254793 407.00 1.17208489e+01 -6.17269204e+00 1.32469025e+01 -0.48473339 0.86564023 407.25 1.08865793e+01 -8.05506248e+00 1.35425862e+01 -0.63701061 0.87445629 407.50 1.00436510e+01 -9.90171924e+00 1.41038637e+01 -0.77828226 0.83798114 407.75 8.72410114e+00 -1.14249118e+01 1.43749279e+01 -0.91864576 0.84510665 408.00 4.70883457e+00 -1.15086904e+01 1.24347529e+01 -1.18242298 0.76076921 408.25 3.06301766e+00 -1.02225950e+01 1.06716225e+01 -1.27967709 0.71729893 408.50 3.71788721e+00 -7.87956946e+00 8.71265173e+00 -1.12993034 0.65876688 408.75 3.20192965e+00 -7.15847175e+00 7.84194308e+00 -1.15019637 0.66810464 409.00 4.84041980e+00 -7.68519413e+00 9.08250365e+00 -1.00872626 0.72148562 409.25 5.12387943e+00 -8.10044309e+00 9.58495272e+00 -1.00679114 0.78138797 409.50 4.33575121e+00 -8.23191294e+00 9.30393085e+00 -1.08601732 0.79501738 409.75 3.55689351e+00 -9.38016565e+00 1.00318991e+01 -1.20835465 0.80587070 410.00 2.87889703e+00 -9.43881109e+00 9.86809014e+00 -1.27475293 0.79133613 410.25 2.77016091e+00 -9.23101606e+00 9.63770974e+00 -1.27925445 0.79214777 410.50 2.42511688e+00 -1.05662808e+01 1.08410093e+01 -1.34518890 0.74970318 410.75 2.26738337e+00 -1.23424541e+01 1.25489920e+01 -1.38911599 0.82101110 411.00 2.08570765e+00 -1.20394784e+01 1.22188059e+01 -1.39925981 0.86466577 411.25 1.55500266e+00 -1.17418731e+01 1.18443918e+01 -1.43913024 0.81308361 411.50 6.53061648e-02 -1.21361651e+01 1.21363409e+01 -1.56541526 0.81265969 411.75 -3.45483204e-01 -1.17140838e+01 1.17191774e+01 -1.60028076 0.80177942 412.00 -2.96444534e+00 -1.21502661e+01 1.25066743e+01 -1.81010295 0.84685272 412.25 -3.80472138e+00 -1.23657163e+01 1.29378068e+01 -1.86928681 0.88324708 412.50 -4.04458997e+00 -1.33348605e+01 1.39347484e+01 -1.86528659 0.91879910 412.75 -4.91092763e+00 -1.26683090e+01 1.35868783e+01 -1.94061498 0.88397181 413.00 -8.37080791e+00 -1.16866154e+01 1.43752358e+01 -2.19236053 0.90300007 413.25 -8.49536440e+00 -1.14091089e+01 1.42245908e+01 -2.21084047 0.90645119 413.50 -8.59564767e+00 -9.99078885e+00 1.31795683e+01 -2.28127266 0.91389435 413.75 -9.50525039e+00 -9.35237636e+00 1.33347939e+01 -2.36430106 0.92222419 414.00 -9.96095753e+00 -8.84783033e+00 1.33230919e+01 -2.41530677 0.95159016 414.25 -1.03666654e+01 -8.56660535e+00 1.34482147e+01 -2.45098349 0.94246812 414.50 -1.10965764e+01 -7.91069430e+00 1.36276591e+01 -2.52226462 0.95139216 414.75 -1.18593064e+01 -7.32643864e+00 1.39398655e+01 -2.58820233 0.95289488 415.00 -1.27775184e+01 -6.10912904e+00 1.41628540e+01 -2.69560546 0.96559425 415.25 -1.27248238e+01 -4.86099514e+00 1.36216891e+01 -2.77669145 0.96388026 415.50 -1.25164122e+01 -3.26263993e+00 1.29346586e+01 -2.88659811 0.96427916 415.75 -1.29471961e+01 -2.01193397e+00 1.31025862e+01 -2.98743031 0.93842039 416.00 -1.27259793e+01 -3.45985382e-01 1.27306816e+01 -3.11441202 0.92101323 416.25 -1.16335907e+01 1.13972576e+00 1.16892860e+01 3.04393576 0.90269186 416.50 -1.06940576e+01 2.68460847e+00 1.10258783e+01 2.89563785 0.92887567 416.75 -9.75079410e+00 3.04182532e+00 1.02142394e+01 2.83920285 0.88872260 417.00 -8.80665316e+00 3.11971512e+00 9.34289903e+00 2.80114089 0.90537850 417.25 -8.22071382e+00 3.38015243e+00 8.88850754e+00 2.75148989 0.88960438 417.50 -6.91450673e+00 3.68076754e+00 7.83316366e+00 2.65242038 0.89766050 417.75 -6.45095296e+00 3.69882468e+00 7.43613462e+00 2.62097935 0.90500811 418.00 -6.17813251e+00 3.80554088e+00 7.25613276e+00 2.58951359 0.95016396 418.25 -5.48689672e+00 3.98765857e+00 6.78287966e+00 2.51313162 0.92531783 418.50 -5.27220581e+00 4.17084572e+00 6.72250758e+00 2.47230172 0.93896927 418.75 -4.54526302e+00 3.99901359e+00 6.05405035e+00 2.42003922 0.91704388 419.00 -4.15751383e+00 3.67612948e+00 5.54967109e+00 2.41756820 0.92568640 419.25 -3.82835851e+00 3.68436471e+00 5.31327320e+00 2.37535880 0.92169216 419.50 -3.88516656e+00 3.75808849e+00 5.40534442e+00 2.37281913 0.93970297 419.75 -3.84773943e+00 3.47372029e+00 5.18380472e+00 2.40723544 0.92496048 420.00 -3.81005482e+00 3.25423229e+00 5.01064323e+00 2.43471335 0.91791838 420.25 -3.54175919e+00 3.20595096e+00 4.77725651e+00 2.40591972 0.92425434 420.50 -3.42230994e+00 3.27119706e+00 4.73423019e+00 2.37876670 0.91670489 420.75 -3.38616004e+00 3.47229326e+00 4.85004126e+00 2.34363646 0.86594658 421.00 -3.31421041e+00 3.51103030e+00 4.82818024e+00 2.32736542 0.87703113 421.25 -2.44998811e+00 3.21893466e+00 4.04524191e+00 2.22137487 0.77531357 421.50 -2.42403243e+00 3.02945564e+00 3.87988849e+00 2.24563144 0.76478289 421.75 -2.22068080e+00 2.83532877e+00 3.60145977e+00 2.23522030 0.83125054 422.00 -2.15722057e+00 2.56962925e+00 3.35508496e+00 2.26916677 0.82469692 422.25 -1.97647416e+00 2.22024062e+00 2.97252730e+00 2.29817462 0.85979157 422.50 -2.04033431e+00 1.92498342e+00 2.80508917e+00 2.38527624 0.79012246 422.75 -2.27196386e+00 1.47175746e+00 2.70700753e+00 2.56677199 0.75339150 423.00 -2.65496804e+00 1.33443670e+00 2.97146035e+00 2.67585224 0.74914787 423.25 -3.94120812e+00 7.08534528e-01 4.00439041e+00 2.96371672 0.83942613 423.50 -4.47048492e+00 7.79780067e-01 4.53798329e+00 2.96890154 0.85369723 423.75 -5.59109770e+00 1.30785664e+00 5.74202599e+00 2.91180661 0.91872737 424.00 -5.93977152e+00 1.69850348e+00 6.17784750e+00 2.86307107 0.89644216 424.25 -6.34099629e+00 2.38093585e+00 6.77326284e+00 2.78239866 0.88740656 424.50 -7.01256103e+00 3.09724578e+00 7.66609051e+00 2.72568656 0.88120297 424.75 -7.57083083e+00 4.30829116e+00 8.71084682e+00 2.62423049 0.87284919 425.00 -7.94618891e+00 5.79236083e+00 9.83327831e+00 2.51170133 0.86056119 425.25 -8.70601874e+00 7.40111059e+00 1.14267756e+01 2.43703227 0.89888462 425.50 -8.20668641e+00 9.27363961e+00 1.23834605e+01 2.29523275 0.87189565 425.75 -8.04627361e+00 1.15689135e+01 1.40919225e+01 2.17850126 0.86376058 426.00 -5.99049288e+00 1.36273328e+01 1.48859062e+01 1.98496295 0.84539747 426.25 -3.12778062e+00 1.56691457e+01 1.59782709e+01 1.76782069 0.85479246 426.50 5.02476988e-01 1.51191771e+01 1.51275245e+01 1.53757414 0.75395753 426.75 4.62927422e+00 1.55083614e+01 1.61845437e+01 1.28071457 0.78137150 427.00 6.20892649e+00 1.43577322e+01 1.56427377e+01 1.16263681 0.77395129 427.25 7.66757950e+00 1.39952808e+01 1.59580594e+01 1.06959073 0.82448827 427.50 9.43337427e+00 1.22995988e+01 1.55006026e+01 0.91652510 0.74949294 427.75 1.17049631e+01 1.12977694e+01 1.62679364e+01 0.76769804 0.82207794 428.00 1.25119307e+01 9.32837560e+00 1.56066332e+01 0.64065245 0.78128346 428.25 1.38443237e+01 6.45733932e+00 1.52762079e+01 0.43642873 0.77824142 428.50 1.32028139e+01 4.19718430e+00 1.38539038e+01 0.30779752 0.75999853 428.75 1.41665819e+01 3.32284871e+00 1.45510606e+01 0.23039062 0.81564890 429.00 1.41583133e+01 1.49554571e+00 1.42370816e+01 0.10523996 0.81500889 429.25 1.47137448e+01 4.24169597e-01 1.47198575e+01 0.02882014 0.90611873 429.50 1.48164737e+01 -1.59270756e+00 1.49018324e+01 -0.10708452 0.88596729 429.75 1.46023860e+01 -2.91541359e+00 1.48905780e+01 -0.19706211 0.89596740 430.00 1.26653120e+01 -2.66246283e+00 1.29421341e+01 -0.20719994 0.85969375 430.25 1.23771775e+01 -3.18698742e+00 1.27809003e+01 -0.25201465 0.89124338 430.50 1.22802326e+01 -3.97819267e+00 1.29085293e+01 -0.31328275 0.89835263 430.75 1.18338205e+01 -4.71053907e+00 1.27368947e+01 -0.37883055 0.89796234 431.00 1.25067819e+01 -4.70297820e+00 1.33617961e+01 -0.35967709 0.90412692 431.25 1.25429861e+01 -4.69054421e+00 1.33913295e+01 -0.35785642 0.90707921 431.50 1.18456364e+01 -4.65850616e+00 1.27287384e+01 -0.37468923 0.90905684 431.75 1.15504864e+01 -4.19189255e+00 1.22876238e+01 -0.34813740 0.91767380 432.00 1.15522549e+01 -3.59136363e+00 1.20976231e+01 -0.30140821 0.93526819 432.25 1.14483389e+01 -3.56036450e+00 1.19891893e+01 -0.30151225 0.92511731 432.50 1.31177321e+01 -2.75060855e+00 1.34030125e+01 -0.20669171 0.92980876 432.75 1.38307222e+01 -2.10040699e+00 1.39893026e+01 -0.15071372 0.94246928 433.00 1.68324377e+01 -3.82636117e+00 1.72618655e+01 -0.22352220 0.94101069 433.25 1.70782659e+01 -6.27600539e+00 1.81949281e+01 -0.35216590 0.95575431 433.50 1.58750378e+01 -7.63381193e+00 1.76151046e+01 -0.44822593 0.97238544 433.75 1.51392095e+01 -7.94012822e+00 1.70950666e+01 -0.48303490 0.96216214 434.00 1.41803994e+01 -8.40504021e+00 1.64841872e+01 -0.53505113 0.96859180 434.25 1.41159827e+01 -9.15496213e+00 1.68248120e+01 -0.57535729 0.95938143 434.50 1.31582658e+01 -1.08350407e+01 1.70451772e+01 -0.68887103 0.95676103 434.75 1.16336821e+01 -1.14478304e+01 1.63216231e+01 -0.77734637 0.94604556 435.00 8.91308573e+00 -1.09128942e+01 1.40902220e+01 -0.88592622 0.94262623 435.25 7.57665352e+00 -1.04498846e+01 1.29075856e+01 -0.94345758 0.93278029 435.50 6.73382953e+00 -9.63703247e+00 1.17565665e+01 -0.96091305 0.94656285 435.75 5.35593731e+00 -8.93388888e+00 1.04163542e+01 -1.03073871 0.91586030 436.00 4.38996999e+00 -7.49552636e+00 8.68646948e+00 -1.04097377 0.95074389 436.25 4.38396830e+00 -6.10958607e+00 7.51972207e+00 -0.94838493 0.92505402 436.50 4.33961866e+00 -4.77680080e+00 6.45369010e+00 -0.83331692 0.95397664 436.75 4.61967041e+00 -4.05821200e+00 6.14901938e+00 -0.72078828 0.94258528 437.00 4.98884620e+00 -3.46360020e+00 6.07331152e+00 -0.60686915 0.96956392 437.25 5.39888839e+00 -3.13163705e+00 6.24140580e+00 -0.52562285 0.96322597 437.50 5.78635668e+00 -2.75141160e+00 6.40719826e+00 -0.44385607 0.96773027 437.75 5.83897321e+00 -2.44238019e+00 6.32920446e+00 -0.39617295 0.96158843 438.00 5.89344725e+00 -2.37485180e+00 6.35394693e+00 -0.38305962 0.96374301 438.25 6.16056289e+00 -2.21587244e+00 6.54695546e+00 -0.34527818 0.96023267 438.50 6.26674678e+00 -2.14263508e+00 6.62291479e+00 -0.32944555 0.97085266 438.75 6.27852353e+00 -2.11626800e+00 6.62559038e+00 -0.32510492 0.95612810 439.00 6.41056406e+00 -2.24421938e+00 6.79204330e+00 -0.33674735 0.97239528 439.25 6.39698083e+00 -2.41008258e+00 6.83592435e+00 -0.36030678 0.96584786 439.50 6.27018796e+00 -2.36638967e+00 6.70186967e+00 -0.36087601 0.97528211 439.75 6.31101771e+00 -2.41798213e+00 6.75837126e+00 -0.36588501 0.97086446 440.00 6.29886909e+00 -2.30988392e+00 6.70904729e+00 -0.35148658 0.97515867 440.25 6.04108566e+00 -2.06965872e+00 6.38578133e+00 -0.33006469 0.95308442 440.50 6.19181015e+00 -2.05497613e+00 6.52391292e+00 -0.32044754 0.95075197 440.75 6.65877678e+00 -1.94859186e+00 6.93803419e+00 -0.28468639 0.96039993 441.00 6.78097189e+00 -1.86217662e+00 7.03201831e+00 -0.26801099 0.95640678 441.25 7.05444076e+00 -2.65596031e+00 7.53785510e+00 -0.36008054 0.95485152 441.50 7.11418747e+00 -2.86863441e+00 7.67077093e+00 -0.38328541 0.96466124 441.75 6.63943403e+00 -3.22474846e+00 7.38113046e+00 -0.45213930 0.95013144 442.00 6.28927402e+00 -3.65958675e+00 7.27650623e+00 -0.52698751 0.95088968 442.25 5.86480995e+00 -3.86297795e+00 7.02271987e+00 -0.58244642 0.95185259 442.50 5.62310683e+00 -3.89748894e+00 6.84176516e+00 -0.60609371 0.95374394 442.75 5.27886336e+00 -3.73055129e+00 6.46400892e+00 -0.61520576 0.95684130 443.00 5.23095141e+00 -3.51182355e+00 6.30045691e+00 -0.59124111 0.96643730 443.25 4.98073039e+00 -3.35747545e+00 6.00668932e+00 -0.59312630 0.96179768 443.50 4.89695728e+00 -3.34134335e+00 5.92830212e+00 -0.59876855 0.95262361 443.75 4.49467325e+00 -3.39923156e+00 5.63532278e+00 -0.64750822 0.93046852 444.00 4.41858339e+00 -3.21446998e+00 5.46412815e+00 -0.62893760 0.93324030 444.25 4.61974395e+00 -3.28266146e+00 5.66726569e+00 -0.61778619 0.93273974 444.50 4.77742870e+00 -3.35564716e+00 5.83816691e+00 -0.61233226 0.93216144 444.75 4.71596795e+00 -3.43148357e+00 5.83227513e+00 -0.62903045 0.94450160 445.00 4.68434622e+00 -3.44075432e+00 5.81221901e+00 -0.63352123 0.93824657 445.25 4.52159683e+00 -4.00159042e+00 6.03800992e+00 -0.72446290 0.93957964 445.50 4.04505155e+00 -4.13866148e+00 5.78713754e+00 -0.79683623 0.93724734 445.75 3.45568408e+00 -3.94502847e+00 5.24452115e+00 -0.85142331 0.94265578 446.00 3.39791228e+00 -4.00242588e+00 5.25025912e+00 -0.86690449 0.91750821 446.25 3.46609010e+00 -4.25480683e+00 5.48791051e+00 -0.88719855 0.90360616 446.50 3.28876410e+00 -4.39635147e+00 5.49034384e+00 -0.92853368 0.87703819 446.75 3.20417091e+00 -4.61152016e+00 5.61540999e+00 -0.96355615 0.85395470 447.00 2.39037682e+00 -5.04017960e+00 5.57828932e+00 -1.12794850 0.79961201 447.25 1.02196910e+00 -4.96379793e+00 5.06790990e+00 -1.36774904 0.85222353 447.50 5.56721570e-01 -4.63159679e+00 4.66493598e+00 -1.45116947 0.85546925 447.75 -1.21534729e-01 -4.28119983e+00 4.28292455e+00 -1.59917671 0.85280726 448.00 -3.05976678e-01 -3.28173156e+00 3.29596477e+00 -1.66376391 0.78224282 448.25 -3.87696056e-01 -3.10463223e+00 3.12874568e+00 -1.69502986 0.87909020 448.50 -2.37130175e-01 -3.06133467e+00 3.07050495e+00 -1.64810170 0.85730253 448.75 1.67945361e-02 -2.75882445e+00 2.75887557e+00 -1.56470883 0.84768325 449.00 -1.03000789e-02 -2.59248463e+00 2.59250509e+00 -1.57476936 0.89741635 449.25 -5.27247135e-02 -2.56653877e+00 2.56708027e+00 -1.59133656 0.93984114 449.50 -1.12929681e-01 -2.49440252e+00 2.49695756e+00 -1.61603867 0.90989338 449.75 -2.18216845e-01 -2.48812930e+00 2.49768013e+00 -1.65827567 0.90540314 450.00 -6.05059429e-01 -2.31494986e+00 2.39271598e+00 -1.82644761 0.84040000 450.25 -8.91725388e-01 -2.10932581e+00 2.29007196e+00 -1.97076284 0.86280597 450.50 -1.26809645e+00 -1.53120685e+00 1.98813054e+00 -2.26247843 0.80668694 450.75 -1.36210539e+00 -1.19472774e+00 1.81182380e+00 -2.42156410 0.80477930 451.00 -1.48434836e+00 -5.94257771e-01 1.59888472e+00 -2.76078522 0.78972455 451.25 -1.32351772e+00 -2.04907545e-01 1.33928573e+00 -2.98799174 0.76321696 451.50 -7.70454414e-01 1.14009530e-01 7.78844129e-01 2.99468178 0.54586523 451.75 -4.76253610e-01 1.76974524e-01 5.08072321e-01 2.78580856 0.39277999 452.00 -4.07615826e-01 2.25687895e-02 4.08240140e-01 3.08628133 0.34498289 452.25 -3.73103029e-01 4.56614325e-02 3.75886734e-01 3.01981532 0.32625780 452.50 -3.44964468e-01 2.88656667e-01 4.49803463e-01 2.44482833 0.45370469 452.75 -3.62615032e-01 3.74543127e-01 5.21317768e-01 2.34001471 0.56800899 453.00 -3.84932925e-01 5.04983703e-01 6.34966060e-01 2.22210284 0.53009568 453.25 -1.89561217e-01 6.76711494e-01 7.02760202e-01 1.84391739 0.59756960 453.50 -3.16261524e-03 8.76791926e-01 8.76797629e-01 1.57440334 0.83471456 453.75 9.95463710e-02 9.56855687e-01 9.62019899e-01 1.46713436 0.87120588 454.00 2.64629835e-01 1.12613795e+00 1.15681271e+00 1.33999496 0.89506098 454.25 4.38023441e-01 1.17116957e+00 1.25040102e+00 1.21289815 0.90503451 454.50 7.00527537e-01 1.16475138e+00 1.35918527e+00 1.02931901 0.94053737 454.75 8.62955851e-01 1.08232736e+00 1.38424179e+00 0.89769472 0.89674998 455.00 9.67727925e-01 5.74196732e-01 1.12525518e+00 0.53551191 0.85391532 455.25 7.64777345e-01 4.08529802e-01 8.67053047e-01 0.49061732 0.75389371 455.50 3.15466979e-01 2.82999037e-01 4.23801687e-01 0.73119936 0.50180034 455.75 8.51677733e-02 3.85125225e-01 3.94429954e-01 1.35315599 0.42769484 456.00 -3.08986693e-01 6.50462718e-01 7.20121187e-01 2.01426586 0.61694079 456.25 -5.02857806e-01 9.77005798e-01 1.09882041e+00 2.04612893 0.68525843 456.50 -6.89278437e-01 1.60834180e+00 1.74981945e+00 1.97568239 0.87340414 456.75 -7.38620332e-01 2.10057920e+00 2.22665511e+00 1.90891984 0.86411886 457.00 -8.07117945e-01 2.86296841e+00 2.97456341e+00 1.84558129 0.90588597 457.25 -4.55512742e-01 3.44115241e+00 3.47117008e+00 1.70240335 0.83905174 457.50 6.30860801e-01 4.20097836e+00 4.24808245e+00 1.42174015 0.91353446 457.75 1.49280612e+00 4.18577001e+00 4.44400053e+00 1.22821989 0.89242350 458.00 2.34528228e+00 4.20660813e+00 4.81621230e+00 1.06219538 0.92486175 458.25 2.82747795e+00 3.81506362e+00 4.74861474e+00 0.93299287 0.91570246 458.50 3.42164596e+00 3.52673232e+00 4.91380728e+00 0.80052088 0.94682651 458.75 3.75140497e+00 2.97359307e+00 4.78699227e+00 0.67025000 0.91772531 459.00 4.23623710e+00 2.44341125e+00 4.89039501e+00 0.52317706 0.94788753 459.25 4.25286559e+00 1.91873554e+00 4.66566306e+00 0.42382065 0.93592079 459.50 4.20510448e+00 1.57185297e+00 4.48927894e+00 0.35771505 0.95079298 459.75 3.99062521e+00 1.44390776e+00 4.24381423e+00 0.34717021 0.93829872 460.00 4.12318537e+00 1.51016015e+00 4.39104103e+00 0.35108676 0.95288067 460.25 4.60543588e+00 1.58519977e+00 4.87061577e+00 0.33150016 0.93214138 460.50 5.21569777e+00 1.16279733e+00 5.34374408e+00 0.21935461 0.92304984 460.75 5.56717204e+00 -4.15552859e-01 5.58265965e+00 -0.07450527 0.88817301 461.00 5.33330561e+00 -1.22718356e+00 5.47267103e+00 -0.22616157 0.92398936 461.25 4.18519684e+00 -1.69204174e+00 4.51429704e+00 -0.38420092 0.88355556 461.50 3.55189344e+00 -1.91405144e+00 4.03479119e+00 -0.49426727 0.89036588 461.75 2.57207967e+00 -1.83657997e+00 3.16047778e+00 -0.62008991 0.81060944 462.00 2.14903973e+00 -1.51594032e+00 2.62991385e+00 -0.61434333 0.77667208 462.25 2.17208975e+00 -1.24635715e+00 2.50427235e+00 -0.52093615 0.74504190 462.50 2.24394120e+00 -9.28492282e-01 2.42845013e+00 -0.39232678 0.72324928 462.75 2.43687740e+00 -1.19297007e+00 2.71321747e+00 -0.45525164 0.67347855 463.00 2.56558491e+00 -1.52021362e+00 2.98215952e+00 -0.53491671 0.66190499 463.25 1.58731809e+00 -2.49948209e+00 2.96091024e+00 -1.00499640 0.63138706 463.50 8.43700555e-01 -2.54299013e+00 2.67929644e+00 -1.25044893 0.49646544 463.75 -1.38581885e+00 -8.31449094e-01 1.61610689e+00 -2.60119555 0.36959613 464.00 -1.60205676e+00 -2.19404765e-02 1.60220699e+00 -3.12789832 0.45916920 464.25 -1.19337686e+00 8.14778785e-01 1.44499578e+00 2.54253751 0.44413340 464.50 -1.17130863e+00 1.23951636e+00 1.70539284e+00 2.32790976 0.56172214 464.75 -1.09815243e+00 2.12183413e+00 2.38916698e+00 2.04838411 0.77126841 465.00 -7.88106992e-01 2.85686096e+00 2.96357338e+00 1.83996623 0.77747581 465.25 1.49408929e-01 3.71147088e+00 3.71447696e+00 1.53056206 0.92011774 465.50 4.63828580e-01 3.92907741e+00 3.95636023e+00 1.45328991 0.92680929 465.75 1.11737927e+00 3.98463249e+00 4.13833693e+00 1.29739619 0.91246016 466.00 1.58490566e+00 3.78760876e+00 4.10583805e+00 1.17449096 0.92422683 466.25 1.76387005e+00 3.48658348e+00 3.90736508e+00 1.10243816 0.94585964 466.50 1.63548309e+00 3.50374455e+00 3.86665628e+00 1.13407489 0.92681537 466.75 1.30428161e+00 4.14484529e+00 4.34521495e+00 1.26593066 0.92918574 467.00 1.16648254e+00 4.57442458e+00 4.72080944e+00 1.32111647 0.91246961 467.25 1.08810786e+00 5.58471087e+00 5.68972532e+00 1.37837016 0.90532542 467.50 1.46988668e+00 6.81710587e+00 6.97377224e+00 1.35843012 0.88485319 467.75 2.59478942e+00 8.44169276e+00 8.83148395e+00 1.27258468 0.93867678 468.00 3.88277014e+00 8.81105448e+00 9.62863360e+00 1.15572800 0.90900300 468.25 5.80791259e+00 9.48616365e+00 1.11229110e+01 1.02141745 0.93482398 468.50 7.87629350e+00 8.93740978e+00 1.19127366e+01 0.84842478 0.90947904 468.75 9.91626187e+00 7.88724362e+00 1.26704720e+01 0.67192043 0.93294451 469.00 1.09517273e+01 6.44947841e+00 1.27096854e+01 0.53221817 0.91819582 469.25 1.18718092e+01 5.20761633e+00 1.29637618e+01 0.41337862 0.93016393 469.50 1.15005021e+01 4.28782270e+00 1.22738329e+01 0.35687376 0.92519628 469.75 1.17320930e+01 3.58094871e+00 1.22664257e+01 0.29624506 0.94542482 470.00 1.20967116e+01 3.80546031e+00 1.26811656e+01 0.30478447 0.92200152 470.25 1.28989405e+01 3.89941421e+00 1.34754628e+01 0.29357013 0.92883570 470.50 1.45127280e+01 3.39656283e+00 1.49048956e+01 0.22990227 0.87263227 470.75 1.71155109e+01 2.94173844e+00 1.73664774e+01 0.17021249 0.89043436 471.00 1.70874022e+01 -6.40939941e-01 1.70994186e+01 -0.03749193 0.77707986 471.25 1.74943030e+01 -4.73112859e+00 1.81227541e+01 -0.26412026 0.76844062 471.50 1.56772625e+01 -9.07013081e+00 1.81119804e+01 -0.52450052 0.65937991 471.75 1.65263651e+01 -1.20814414e+01 2.04714916e+01 -0.63125617 0.68794594 472.00 9.58689774e+00 -1.43302120e+01 1.72413336e+01 -0.98118076 0.54836219 472.25 6.66250664e+00 -1.63602338e+01 1.76648307e+01 -1.18406603 0.59474347 472.50 4.93975341e-02 -1.45058267e+01 1.45059108e+01 -1.56739098 0.70548692 472.75 -2.37721742e+00 -1.42223148e+01 1.44196186e+01 -1.73641233 0.81500180 473.00 -3.52954930e+00 -1.24196057e+01 1.29114028e+01 -1.84768778 0.86572413 473.25 -3.66133271e+00 -1.17069698e+01 1.22661526e+01 -1.87390722 0.90430856 473.50 -3.52746658e+00 -1.08317237e+01 1.13916311e+01 -1.88562568 0.91409722 473.75 -3.17023653e+00 -9.66573625e+00 1.01723575e+01 -1.88772755 0.91461343 474.00 -3.26732776e+00 -8.00670960e+00 8.64770659e+00 -1.95824337 0.94785682 474.25 -3.24576665e+00 -7.61332632e+00 8.27633607e+00 -1.97379043 0.95519047 474.50 -2.80266863e+00 -6.72740206e+00 7.28785908e+00 -1.96553481 0.94603213 474.75 -2.46617043e+00 -6.46079470e+00 6.91548008e+00 -1.93543949 0.93601965 475.00 -1.33932787e+00 -6.01778034e+00 6.16502062e+00 -1.78978882 0.92591806 475.25 -9.12397918e-01 -5.78591686e+00 5.85741444e+00 -1.72720125 0.90715606 475.50 -2.19772490e-01 -5.85159522e+00 5.85572084e+00 -1.60833639 0.85149787 475.75 7.28426582e-02 -6.50108694e+00 6.50149502e+00 -1.55959211 0.86043679 476.00 -1.03673229e-01 -7.08261859e+00 7.08337732e+00 -1.58543298 0.90099794 476.25 -2.46285923e-01 -7.46276168e+00 7.46682454e+00 -1.60378633 0.86341440 476.50 -1.07114046e+00 -9.04578462e+00 9.10898245e+00 -1.68866070 0.89762598 476.75 -1.79946794e+00 -9.21165772e+00 9.38577236e+00 -1.76371369 0.89206575 477.00 -2.76067928e+00 -9.59107583e+00 9.98048524e+00 -1.85105862 0.90640669 477.25 -3.43977031e+00 -9.18993989e+00 9.81259471e+00 -1.92895085 0.88227328 477.50 -4.29482675e+00 -8.27956957e+00 9.32720800e+00 -2.04931214 0.86916953 477.75 -4.03598875e+00 -7.72638454e+00 8.71700770e+00 -2.05217502 0.85152343 478.00 -3.44848160e+00 -8.44648479e+00 9.12332892e+00 -1.95841520 0.88391835 478.25 -2.10514009e+00 -9.27353252e+00 9.50947003e+00 -1.79401852 0.76896041 478.50 7.21191238e-01 -1.35220567e+01 1.35412753e+01 -1.51751238 0.68568202 478.75 1.83371639e+00 -1.14411204e+01 1.15871374e+01 -1.41187372 0.22615087 479.00 -2.43187005e+00 8.22464388e+00 8.57664030e+00 1.85828594 0.06229591 479.25 -7.70669257e+00 1.58801566e+01 1.76514159e+01 2.02261761 0.48818386 479.50 -7.92847794e+00 1.63562344e+01 1.81765554e+01 2.02215944 0.80244942 479.75 -6.16406420e+00 1.41258565e+01 1.54121870e+01 1.98225579 0.84345970 480.00 -4.62810603e+00 1.38523438e+01 1.46050263e+01 1.89323919 0.90184757 480.25 -4.31821433e+00 1.32962055e+01 1.39798447e+01 1.88482057 0.88398792 480.50 -3.77014651e+00 1.34530339e+01 1.39713322e+01 1.84403228 0.89893969 480.75 -1.60529893e+00 1.46110957e+01 1.46990171e+01 1.68022591 0.85115972 481.00 -5.83745311e-01 1.49723219e+01 1.49836972e+01 1.60976489 0.82869992 481.25 2.75514238e+00 1.49977979e+01 1.52487623e+01 1.38911881 0.71760087 481.50 7.39137787e+00 1.58429221e+01 1.74822953e+01 1.13427210 0.68212518 481.75 1.37703003e+01 9.80707363e+00 1.69056164e+01 0.61886057 0.41817715 482.00 1.51339765e+01 -2.62384871e+00 1.53597470e+01 -0.17166823 0.33817362 482.25 5.21762145e+00 -1.31173330e+01 1.41169401e+01 -1.19221779 0.63775841 482.50 3.66746457e+00 -1.12098295e+01 1.17945145e+01 -1.25460745 0.79176263 482.75 1.41890767e+00 -8.54880848e+00 8.66576167e+00 -1.40631851 0.83762597 483.00 1.07645091e+00 -7.80316539e+00 7.87706397e+00 -1.43371101 0.89622815 483.25 -1.98444376e-02 -6.15425481e+00 6.15428680e+00 -1.57402082 0.88500117 483.50 -5.56409795e-01 -5.96644246e+00 5.99233072e+00 -1.66378393 0.87383963 483.75 -2.39677728e+00 -5.33323534e+00 5.84704545e+00 -1.99315451 0.86488945 484.00 -2.68478603e+00 -4.63120608e+00 5.35314354e+00 -2.09616787 0.84212017 484.25 -3.52687306e+00 -2.02562185e+00 4.06718299e+00 -2.62025504 0.80458721 484.50 -3.56958180e+00 -1.44768953e+00 3.85197601e+00 -2.75629999 0.87747033 484.75 -2.71168683e+00 -1.69450783e-01 2.71697608e+00 -3.07918473 0.79638666 485.00 -2.01092627e+00 1.59909227e-01 2.01727425e+00 3.06223945 0.80084113 485.25 -1.23816521e+00 3.27385563e-01 1.28071636e+00 2.88309655 0.78178589 485.50 -9.48292929e-01 2.82392212e-01 9.89446735e-01 2.85216455 0.76383466 485.75 -6.08641749e-01 1.07877560e-01 6.18128099e-01 2.96617136 0.68000365 486.00 -4.54478443e-01 1.40840265e-02 4.54696618e-01 3.11061314 0.53846596 486.25 -2.77479204e-01 -1.63147104e-01 3.21887692e-01 -2.61007198 0.53895888 486.50 -2.42152181e-01 -2.46702515e-01 3.45687445e-01 -2.34688661 0.59844057 486.75 -1.45518117e-01 -3.56533953e-01 3.85086979e-01 -1.95830584 0.58666342 487.00 -1.80251764e-01 -5.07120352e-01 5.38202332e-01 -1.91231081 0.66218940 487.25 -3.11496719e-01 -7.11654209e-01 7.76840987e-01 -1.98338131 0.85553173 487.50 -4.23634292e-01 -7.45765316e-01 8.57689874e-01 -2.08739415 0.88841063 487.75 -5.71502503e-01 -7.37738129e-01 9.33205582e-01 -2.22989927 0.92368746 488.00 -7.70970023e-01 -6.56744624e-01 1.01277257e+00 -2.43603020 0.92260851 488.25 -9.05522173e-01 -4.76316987e-01 1.02315604e+00 -2.65735139 0.95497291 488.50 -9.27936965e-01 -3.46077462e-01 9.90371961e-01 -2.78461726 0.94332045 488.75 -9.36598277e-01 -1.55009235e-01 9.49338820e-01 -2.97757702 0.93884215 489.00 -8.97955910e-01 -1.90912323e-02 8.98158834e-01 -3.12033509 0.92734893 489.25 -8.01420406e-01 1.05979771e-01 8.08397414e-01 3.01011559 0.91908537 489.50 -6.63142143e-01 1.61448317e-01 6.82512316e-01 2.90277908 0.87615830 489.75 -5.36786248e-01 1.61858311e-01 5.60658174e-01 2.84873081 0.89790284 490.00 -4.80837604e-01 7.84886285e-02 4.87201464e-01 2.97978656 0.82619492 490.25 -4.31115849e-01 -7.80391350e-03 4.31186476e-01 -3.12349297 0.78905717 490.50 -4.85414897e-01 -2.21595548e-02 4.85920434e-01 -3.09597357 0.77294919 490.75 -5.15472044e-01 -4.86164832e-02 5.17759588e-01 -3.04755633 0.81510811 491.00 -4.82093485e-01 -4.16078975e-02 4.83885674e-01 -3.05549930 0.71971424 491.25 -4.89670432e-01 -5.09579194e-02 4.92314779e-01 -3.03790015 0.73801870 491.50 -4.86847621e-01 -1.28536513e-01 5.03529782e-01 -2.88346475 0.65867683 491.75 -5.44326700e-01 -2.30311585e-01 5.91045669e-01 -2.74132158 0.77172489 492.00 -6.06415364e-01 -3.04936671e-01 6.78767977e-01 -2.67566672 0.77002663 492.25 -6.66891981e-01 -3.59842555e-01 7.57780693e-01 -2.64678349 0.77249902 492.50 -8.30681193e-01 -4.83444993e-01 9.61119298e-01 -2.61452391 0.85173516 492.75 -9.86698573e-01 -5.50016143e-01 1.12964235e+00 -2.63306234 0.84711190 493.00 -1.37659960e+00 -8.15039993e-01 1.59978644e+00 -2.60702623 0.84883397 493.25 -1.69722561e+00 -8.64997338e-01 1.90493968e+00 -2.67025193 0.88292256 493.50 -2.18021327e+00 -6.83850114e-01 2.28494658e+00 -2.83764949 0.88153352 493.75 -2.40123090e+00 -5.58707966e-01 2.46537308e+00 -2.91298453 0.89900568 494.00 -3.17314930e+00 -2.48934845e-01 3.18289884e+00 -3.06330260 0.91448755 494.25 -3.43622149e+00 -1.25315379e-01 3.43850579e+00 -3.10513986 0.88534478 494.50 -4.07752464e+00 5.30854210e-01 4.11193548e+00 3.01213050 0.87253387 494.75 -4.41313483e+00 9.61186054e-01 4.51659581e+00 2.92714061 0.89383487 495.00 -4.76662710e+00 1.77191871e+00 5.08531512e+00 2.78568815 0.92706162 495.25 -5.13593579e+00 2.19696123e+00 5.58609658e+00 2.73738439 0.90771996 495.50 -5.62670147e+00 3.51809704e+00 6.63602111e+00 2.58281333 0.89043434 495.75 -5.61352724e+00 4.53581300e+00 7.21701376e+00 2.46198372 0.90648477 496.00 -4.60618117e+00 5.91772652e+00 7.49909276e+00 2.23220843 0.92979517 496.25 -3.96098852e+00 6.48507902e+00 7.59905783e+00 2.11910820 0.91686054 496.50 -2.35982684e+00 7.31324898e+00 7.68455551e+00 1.88292691 0.93412807 496.75 -1.79627393e+00 7.15358475e+00 7.37566097e+00 1.81681117 0.94489939 497.00 -1.56299896e+00 6.79793670e+00 6.97530710e+00 1.79679116 0.95776845 497.25 -1.73856113e+00 6.92085228e+00 7.13588054e+00 1.81690993 0.95742199 497.50 -1.70232848e+00 7.57081685e+00 7.75984472e+00 1.79197180 0.96609036 497.75 -1.30457643e+00 8.13826700e+00 8.24216654e+00 1.72974555 0.94711056 498.00 -1.12931341e+00 9.19979993e+00 9.26885471e+00 1.69293939 0.96473156 498.25 -8.24168446e-01 9.45306500e+00 9.48892468e+00 1.65776174 0.95150902 498.50 -2.14934432e-01 1.07759939e+01 1.07781372e+01 1.59073935 0.95583039 498.75 6.81591152e-01 1.13999560e+01 1.14203137e+01 1.51107849 0.95495866 499.00 2.13587923e+00 1.24742714e+01 1.26558061e+01 1.40121799 0.96568789 499.25 2.81448324e+00 1.26324645e+01 1.29421975e+01 1.35157911 0.95472847 499.50 3.88231274e+00 1.27661568e+01 1.33434295e+01 1.27557340 0.95763899 499.75 4.76555586e+00 1.29637598e+01 1.38119365e+01 1.21852377 0.94978031 500.00 5.43030056e+00 1.33409832e+01 1.44038188e+01 1.18423661 0.96263216 500.25 6.59123464e+00 1.30450095e+01 1.46156303e+01 1.10294267 0.95560720 500.50 7.43510566e+00 1.24821929e+01 1.45287967e+01 1.03357632 0.95679360 500.75 5.82645764e+00 1.32095921e+01 1.44374836e+01 1.15538684 0.92601168 501.00 3.54380676e+00 1.49745627e+01 1.53881804e+01 1.33841646 0.93233262 501.25 1.01834073e+00 1.87654124e+01 1.87930232e+01 1.51658260 0.82594287 501.50 -1.19203432e+00 2.31848495e+01 2.32154731e+01 1.62216546 0.80146747 501.75 -1.01619230e+01 2.22071359e+01 2.44217436e+01 1.99995009 0.49986610 502.00 -1.76763029e+01 1.40549969e+01 2.25830605e+01 2.46982696 0.28409476 502.25 -2.12048804e+01 5.33513005e+00 2.18657395e+01 2.89510947 0.31958657 502.50 -2.11083413e+01 -6.14556028e+00 2.19847671e+01 -2.85828059 0.35730015 502.75 -1.69668657e+01 -9.82222484e+00 1.96048625e+01 -2.61682767 0.47618400 503.00 -1.60354224e+01 -8.24855046e+00 1.80325638e+01 -2.66649501 0.56712244 503.25 -1.05692457e+01 -6.71150009e+00 1.25201113e+01 -2.57583266 0.64455727 503.50 -9.54546763e+00 -6.56990802e+00 1.15879094e+01 -2.53877915 0.73176245 503.75 -5.15738172e+00 -4.61870506e+00 6.92322342e+00 -2.41124029 0.55691607 504.00 -3.96773151e+00 -4.11722559e+00 5.71790520e+00 -2.33770620 0.58764852 504.25 -1.85404836e+00 -3.24285830e+00 3.73545517e+00 -2.09017173 0.50379802 504.50 -8.53332414e-01 -3.35679689e+00 3.46356197e+00 -1.81973370 0.53793008 504.75 -1.24949461e-01 -3.50736940e+00 3.50959435e+00 -1.60640610 0.55856920 505.00 3.09536983e-01 -2.63929883e+00 2.65738809e+00 -1.45404964 0.42635102 505.25 1.58756874e+00 -1.16857353e+00 1.97127842e+00 -0.63453096 0.23676482 505.50 2.87015415e+00 -7.55402439e-01 2.96789786e+00 -0.25735588 0.47338875 505.75 4.21910412e+00 -3.25623796e-01 4.23165103e+00 -0.07702573 0.70262194 506.00 5.64317469e+00 -4.43135309e-01 5.66054675e+00 -0.07836508 0.79543463 506.25 7.31645905e+00 -4.21922146e-01 7.32861456e+00 -0.05760374 0.81264264 506.50 9.18976899e+00 -1.11760444e+00 9.25747772e+00 -0.12101970 0.84117321 506.75 1.13513911e+01 -3.64179426e+00 1.19212728e+01 -0.31044987 0.92639077 507.00 1.18610742e+01 -4.96981566e+00 1.28601769e+01 -0.39677947 0.90337414 507.25 1.20960743e+01 -8.26956238e+00 1.46526679e+01 -0.59967289 0.92773881 507.50 1.28543436e+01 -8.73697063e+00 1.55424839e+01 -0.59696474 0.89853137 507.75 1.58281235e+01 -1.16998934e+01 1.96829114e+01 -0.63654276 0.93835624 508.00 1.60148719e+01 -1.53291060e+01 2.21688433e+01 -0.76352294 0.93666082 508.25 1.50950246e+01 -2.22358533e+01 2.68755082e+01 -0.97439983 0.95330812 508.50 1.28303729e+01 -2.67982444e+01 2.97113509e+01 -1.12427112 0.94982012 508.75 9.26427538e+00 -3.01690550e+01 3.15594467e+01 -1.27285799 0.95378501 509.00 1.52168446e+00 -3.14607565e+01 3.14975352e+01 -1.52246629 0.90635938 509.25 -6.79647057e+00 -3.30530880e+01 3.37446090e+01 -1.77359259 0.95087118 509.50 -1.37329136e+01 -2.97748988e+01 3.27892896e+01 -2.00294527 0.94328622 509.75 -2.00730486e+01 -2.39788160e+01 3.12715669e+01 -2.26776280 0.96833084 510.00 -2.17675094e+01 -1.85156308e+01 2.85771420e+01 -2.43674537 0.93697425 510.25 -2.07213547e+01 -1.20557134e+01 2.39732093e+01 -2.61466196 0.95159940 510.50 -1.90287657e+01 -6.52690277e+00 2.01170173e+01 -2.81116578 0.88867997 510.75 -1.63840404e+01 -3.19947390e+00 1.66935141e+01 -2.94873974 0.93609048 511.00 -1.34203438e+01 -1.95992066e+00 1.35627032e+01 -2.99657680 0.93975173 511.25 -1.14891701e+01 -1.66113261e+00 1.16086343e+01 -2.99800519 0.95917417 511.50 -1.03030279e+01 -2.25886705e+00 1.05477421e+01 -2.92576449 0.95911553 511.75 -1.00297851e+01 -2.43513322e+00 1.03211658e+01 -2.90341114 0.96057344 512.00 -9.78596982e+00 -1.36353812e+00 9.88050816e+00 -3.00314798 0.93767194 512.25 -9.27915339e+00 -3.52192472e-01 9.28583476e+00 -3.10365563 0.95234472 512.50 -8.11252501e+00 6.09207259e-01 8.13536696e+00 3.06663868 0.94269917 512.75 -6.71845227e+00 6.45265735e-01 6.74936803e+00 3.04584254 0.90931547 513.00 -4.57413296e+00 2.83697731e-01 4.58292229e+00 3.07964981 0.84173983 513.25 -3.85832679e+00 2.90485301e-02 3.85843614e+00 3.13406401 0.82927195 513.50 -2.20645752e+00 -1.37727666e+00 2.60102783e+00 -2.58356691 0.56632351 513.75 -1.21866139e+00 -2.17006540e+00 2.48883897e+00 -2.08248526 0.64102506 514.00 -4.19752901e-01 -2.63110603e+00 2.66437824e+00 -1.72899794 0.59690811 514.25 3.60578875e-01 -3.38020708e+00 3.39938480e+00 -1.46452460 0.67449337 514.50 1.22439560e+00 -4.77736101e+00 4.93176670e+00 -1.31990535 0.77734477 514.75 1.66984001e+00 -5.92267156e+00 6.15356840e+00 -1.29598926 0.82095408 515.00 2.96787940e+00 -8.00136462e+00 8.53405788e+00 -1.21560598 0.79036813 515.25 3.81531029e+00 -1.06354620e+01 1.12990993e+01 -1.22636124 0.81142900 515.50 4.74908140e+00 -1.56714592e+01 1.63752376e+01 -1.27655274 0.87415530 515.75 3.69578062e+00 -1.93503036e+01 1.97000772e+01 -1.38207575 0.88620138 516.00 1.74195843e-01 -2.39758130e+01 2.39764458e+01 -1.56353097 0.85495876 516.25 -8.68721329e-01 -2.66269159e+01 2.66410834e+01 -1.60341044 0.74909707 516.50 -4.48764227e+00 -3.11904745e+01 3.15116587e+01 -1.71369428 0.48398660 516.75 -1.74967661e+00 -1.86631823e+01 1.87450192e+01 -1.66427328 0.15380931 517.00 -6.64966182e+00 1.23966241e+01 1.40674906e+01 2.06314521 0.20395942 517.25 -7.99419247e+00 7.71485924e+00 1.11097330e+01 2.37397429 0.32356477 517.50 -1.12926546e+01 1.57660075e+00 1.14021804e+01 3.00287635 0.51227031 517.75 -1.47376469e+01 -1.08474755e+00 1.47775137e+01 -3.06812129 0.71610521 518.00 -1.96384202e+01 -3.70004908e+00 1.99839413e+01 -2.95536702 0.81459673 518.25 -2.08084362e+01 -4.36274100e-01 2.08130092e+01 -3.12062951 0.78592665 518.50 -1.93189125e+01 4.78090083e+00 1.99016932e+01 2.89899416 0.84994692 518.75 -1.74111242e+01 5.33189895e+00 1.82092392e+01 2.84442536 0.84152056 519.00 -1.51506167e+01 4.04821079e+00 1.56821299e+01 2.88049450 0.81288665 519.25 -1.43450584e+01 3.59050883e+00 1.47875777e+01 2.89633555 0.83746278 519.50 -1.51722009e+01 3.43964199e+00 1.55572111e+01 2.91865419 0.86383690 519.75 -1.44305427e+01 3.71845290e+00 1.49019279e+01 2.88939953 0.87450984 520.00 -1.45086076e+01 4.44803309e+00 1.51751341e+01 2.84411115 0.88435137 520.25 -1.29220392e+01 4.56291014e+00 1.37039865e+01 2.80214931 0.86876534 520.50 -1.08995113e+01 4.43379308e+00 1.17668121e+01 2.75524807 0.89457954 520.75 -8.74953970e+00 2.74224533e+00 9.16920686e+00 2.83787354 0.86373430 521.00 -7.03161321e+00 1.33396568e+00 7.15702793e+00 2.95411085 0.86643612 521.25 -5.48851997e+00 -2.58066592e-01 5.49458368e+00 -3.09460792 0.75858641 521.50 -4.08091111e+00 -1.31515565e+00 4.28759488e+00 -2.82983183 0.71140896 521.75 -2.47452547e+00 -2.91177287e+00 3.82121676e+00 -2.27519439 0.57411060 522.00 -1.33669310e+00 -4.45248711e+00 4.64880521e+00 -1.86244823 0.74633719 522.25 -2.17586649e-01 -5.20240294e+00 5.20695116e+00 -1.61259622 0.78755754 522.50 5.38963922e-01 -6.69188136e+00 6.71355035e+00 -1.49042983 0.85253789 522.75 8.48600111e-01 -8.71796978e+00 8.75917343e+00 -1.47376283 0.92859023 523.00 9.71736021e-01 -9.83328410e+00 9.88118146e+00 -1.47229503 0.96045048 523.25 6.33744371e-02 -1.13167477e+01 1.13169252e+01 -1.56519633 0.93295024 523.50 -1.31782333e+00 -1.20926941e+01 1.21642883e+01 -1.67934479 0.95498309 523.75 -1.48810772e+00 -1.11012363e+01 1.12005317e+01 -1.70405079 0.97694108 524.00 -1.42242406e+00 -1.10211990e+01 1.11126108e+01 -1.69914935 0.98293226 524.25 -1.62781142e+00 -1.10514134e+01 1.11706539e+01 -1.71703918 0.98201309 524.50 -1.96035164e+00 -1.10544475e+01 1.12269224e+01 -1.74630769 0.98234051 524.75 -3.40673489e+00 -1.12795063e+01 1.17827460e+01 -1.86411330 0.97672500 525.00 -4.32246950e+00 -1.08872061e+01 1.17138806e+01 -1.94873356 0.97163719 525.25 -6.10134906e+00 -9.53767393e+00 1.13222650e+01 -2.13990403 0.96726723 525.50 -6.80146352e+00 -8.58753230e+00 1.09547075e+01 -2.24065002 0.96631588 525.75 -7.07647122e+00 -6.43422767e+00 9.56429457e+00 -2.40369466 0.95723862 526.00 -7.40398114e+00 -5.14469582e+00 9.01592102e+00 -2.53432783 0.94915306 526.25 -6.99994729e+00 -2.41876720e+00 7.40605812e+00 -2.80889593 0.92245688 526.50 -6.36046772e+00 -1.32378174e+00 6.49676440e+00 -2.93639552 0.92914516 526.75 -4.87877949e+00 -2.70478252e-02 4.87885447e+00 -3.13604874 0.86835009 527.00 -3.74315139e+00 6.44890211e-01 3.79829774e+00 2.97098216 0.83077506 527.25 -2.77575293e+00 7.28643257e-01 2.86979535e+00 2.88488159 0.84671982 527.50 -2.46393978e+00 1.03490881e+00 2.67245870e+00 2.74394600 0.79622657 527.75 -1.57573387e+00 1.78089303e+00 2.37792288e+00 2.29514980 0.70845584 528.00 -8.28785818e-01 1.85532730e+00 2.03202493e+00 1.99090758 0.65084573 528.25 2.43953759e-01 2.11450915e+00 2.12853527e+00 1.45593282 0.64259172 528.50 9.34004040e-01 1.84875670e+00 2.07129546e+00 1.10299214 0.65619676 528.75 1.37471456e+00 1.15330845e+00 1.79442484e+00 0.69804033 0.73165139 529.00 1.40362939e+00 8.76328778e-01 1.65472886e+00 0.55811780 0.68706673 529.25 1.40745315e+00 6.16098173e-01 1.53639231e+00 0.41261165 0.74618468 529.50 1.47081055e+00 8.13564522e-01 1.68082447e+00 0.50525096 0.73378075 529.75 1.47726466e+00 1.02414959e+00 1.79755202e+00 0.60619778 0.85012030 530.00 1.70925465e+00 1.22065168e+00 2.10036710e+00 0.62015476 0.79337136 530.25 2.27853946e+00 1.17114144e+00 2.56189663e+00 0.47477511 0.83116498 530.50 2.57661657e+00 1.11694430e+00 2.80829441e+00 0.40904194 0.86438443 530.75 2.86362343e+00 1.27078405e+00 3.13292694e+00 0.41765921 0.91470653 531.00 3.18090734e+00 1.08826681e+00 3.36191852e+00 0.32964176 0.85879345 531.25 3.60498430e+00 7.71778822e-01 3.68667253e+00 0.21090295 0.88489160 531.50 3.76131640e+00 7.21856544e-01 3.82995796e+00 0.18961047 0.84309682 531.75 4.16776207e+00 3.68567565e-01 4.18402709e+00 0.08820352 0.87186701 532.00 4.03919318e+00 -1.00316974e-01 4.04043872e+00 -0.02483079 0.82725343 532.25 3.78682346e+00 -4.60234228e-01 3.81468838e+00 -0.12094255 0.81590443 532.50 3.37958356e+00 -9.30324327e-01 3.50529434e+00 -0.26862446 0.70453755 532.75 3.39147136e+00 -1.32233811e+00 3.64014506e+00 -0.37177015 0.77401980 533.00 2.83137204e+00 -1.37158173e+00 3.14609346e+00 -0.45110853 0.66602176 533.25 2.50570729e+00 -1.07679953e+00 2.72728185e+00 -0.40587756 0.64923981 533.50 2.48680205e+00 -9.95539128e-01 2.67867180e+00 -0.38079002 0.56236339 533.75 2.43971752e+00 -6.74605053e-01 2.53126718e+00 -0.26976903 0.54996592 534.00 1.94458860e+00 -2.10929079e-02 1.94470300e+00 -0.01084655 0.38458043 534.25 1.70012507e+00 6.58363732e-02 1.70139933e+00 0.03870509 0.39794577 534.50 1.86923308e+00 3.71415377e-01 1.90577587e+00 0.19614461 0.36299060 534.75 1.97027273e+00 3.73348872e-01 2.00533389e+00 0.18727060 0.40199878 535.00 1.70362898e+00 9.35260119e-01 1.94346680e+00 0.50206061 0.36146182 535.25 1.43279500e+00 1.29079168e+00 1.92848248e+00 0.73330698 0.33811184 535.50 1.60964588e+00 2.76978009e+00 3.20353580e+00 1.04435563 0.48298591 535.75 2.11119594e+00 3.34799400e+00 3.95805661e+00 1.00819066 0.58987526 536.00 2.12251005e+00 4.05050822e+00 4.57292748e+00 1.08812510 0.67751506 536.25 2.34103237e+00 4.49454448e+00 5.06767823e+00 1.09059963 0.69268698 536.50 3.53254887e+00 5.02463902e+00 6.14214123e+00 0.95802946 0.72771457 536.75 3.66546588e+00 5.44552145e+00 6.56424740e+00 0.97834230 0.73342834 537.00 4.12644699e+00 6.99893814e+00 8.12481999e+00 1.03807244 0.50942670 537.25 5.21776747e+00 6.76907923e+00 8.54666783e+00 0.91410064 0.38325027 537.50 9.09970553e+00 -7.18231428e-02 9.09998897e+00 -0.00789274 0.31326985 537.75 8.54193953e+00 -3.18671635e+00 9.11701114e+00 -0.35707497 0.35470331 538.00 8.63124500e+00 -3.87684655e+00 9.46194110e+00 -0.42215869 0.51193791 538.25 8.11797973e+00 -2.80179297e+00 8.58787743e+00 -0.33233353 0.48210710 538.50 6.76759407e+00 -3.83105445e+00 7.77671574e+00 -0.51511096 0.44302502 538.75 4.90443780e+00 -3.32140827e+00 5.92328144e+00 -0.59527670 0.26021188 539.00 1.46676563e+00 -5.06955506e+00 5.27747951e+00 -1.28915863 0.17386354 539.25 -2.20536011e+00 -4.51468821e+00 5.02454205e+00 -2.02519005 0.16443454 539.50 -4.60089313e+00 -2.74668025e+00 5.35840181e+00 -2.60339044 0.33093116 539.75 -3.60248823e+00 -6.88811836e-01 3.66774906e+00 -2.95266847 0.23500919 540.00 -2.49724222e+00 1.66189450e+00 2.99968532e+00 2.55440378 0.24771345 540.25 -6.16710222e-01 3.69315804e+00 3.74429537e+00 1.73625688 0.45861038 540.50 9.47304764e-01 4.60557290e+00 4.70198767e+00 1.36793888 0.66487109 540.75 2.60796631e+00 4.66692440e+00 5.34618290e+00 1.06120747 0.68709849 541.00 4.19883174e+00 4.22652361e+00 5.95765808e+00 0.78868488 0.80965837 541.25 5.50309678e+00 3.61548087e+00 6.58451031e+00 0.58127359 0.85657959 541.50 6.04116080e+00 3.36408867e+00 6.91467399e+00 0.50809574 0.91837965 541.75 6.06043034e+00 3.33189594e+00 6.91594871e+00 0.50267335 0.90316550 542.00 6.51239444e+00 3.15249378e+00 7.23529532e+00 0.45082744 0.91800291 542.25 7.33013048e+00 2.65352874e+00 7.79564158e+00 0.34732758 0.91172452 542.50 7.96324245e+00 1.85893600e+00 8.17733901e+00 0.22933270 0.90689764 542.75 6.99513408e+00 1.29647428e+00 7.11426358e+00 0.18325996 0.84063461 543.00 5.92932076e+00 1.34819090e+00 6.08066307e+00 0.22357571 0.84310515 543.25 5.56536041e+00 2.55674772e+00 6.12455675e+00 0.43064655 0.86351433 543.50 5.88891209e+00 3.30841685e+00 6.75462120e+00 0.51186091 0.92394686 543.75 6.73907928e+00 3.92725623e+00 7.79990584e+00 0.52764551 0.93038143 544.00 7.17691237e+00 4.03915300e+00 8.23546162e+00 0.51261592 0.94362146 544.25 7.83765662e+00 4.01677026e+00 8.80700316e+00 0.47359462 0.93861143 544.50 8.39553373e+00 3.79782449e+00 9.21457853e+00 0.42481683 0.95648910 544.75 8.68562505e+00 3.49592716e+00 9.36277678e+00 0.38265603 0.94415037 545.00 8.70746135e+00 3.88303815e+00 9.53403737e+00 0.41947565 0.94650515 545.25 8.47918496e+00 4.08820683e+00 9.41328915e+00 0.44926283 0.92606597 545.50 8.57815286e+00 4.61846813e+00 9.74243062e+00 0.49389281 0.92482759 545.75 9.27834254e+00 5.68431097e+00 1.08811319e+01 0.54966395 0.92832732 546.00 9.73975165e+00 6.07584439e+00 1.14794881e+01 0.55774977 0.93441955 546.25 1.15810344e+01 5.70060304e+00 1.29080298e+01 0.45741721 0.93284043 546.50 1.24081171e+01 5.88194432e+00 1.37316655e+01 0.44266480 0.91947203 546.75 1.18250985e+01 5.03110012e+00 1.28508725e+01 0.40225976 0.74248530 547.00 1.30690107e+01 4.44098830e+00 1.38029497e+01 0.32756872 0.80248981 547.25 1.40910940e+01 2.58758817e+00 1.43267073e+01 0.18160957 0.93054290 547.50 1.34202877e+01 1.60727020e+00 1.35161917e+01 0.11919648 0.94174740 547.75 1.21743508e+01 1.03736683e+00 1.22184675e+01 0.08500388 0.96515948 548.00 1.14508398e+01 9.36585778e-01 1.14890785e+01 0.08161022 0.94929001 548.25 9.33836507e+00 1.50275052e+00 9.45850524e+00 0.15955434 0.95842948 548.50 8.84153844e+00 1.92712464e+00 9.04912213e+00 0.21460613 0.96170681 548.75 8.39688715e+00 2.69534542e+00 8.81887752e+00 0.31060382 0.96944653 549.00 8.14107039e+00 3.24173853e+00 8.76275618e+00 0.37894991 0.97071442 549.25 7.58895358e+00 4.23887538e+00 8.69254168e+00 0.50939037 0.96047584 549.50 7.33138141e+00 4.86961730e+00 8.80126844e+00 0.58630373 0.96405518 549.75 7.31483414e+00 6.01591975e+00 9.47090750e+00 0.68826735 0.97853786 550.00 7.51407697e+00 6.36984690e+00 9.85070060e+00 0.70316997 0.97620792 550.25 7.70115922e+00 7.10004534e+00 1.04746598e+01 0.74480797 0.97185407 550.50 7.95367881e+00 7.21332153e+00 1.07374585e+01 0.73662319 0.96727977 550.75 8.90707762e+00 7.01607677e+00 1.13384904e+01 0.66719386 0.96108346 551.00 9.19591551e+00 6.85173087e+00 1.14678280e+01 0.64034753 0.94965100 551.25 9.05533330e+00 6.16842360e+00 1.09566651e+01 0.59799153 0.94955513 551.50 9.02972377e+00 6.18107936e+00 1.09426529e+01 0.60026496 0.94781305 551.75 9.07297178e+00 5.96054611e+00 1.08557324e+01 0.58124989 0.93618192 552.00 8.20340411e+00 5.75957510e+00 1.00233998e+01 0.61213112 0.90841484 552.25 7.67814223e+00 5.46282655e+00 9.42318110e+00 0.61838762 0.89650714 552.50 6.70515256e+00 4.99790274e+00 8.36290037e+00 0.64053929 0.83767989 552.75 6.44588575e+00 5.34979335e+00 8.37673755e+00 0.69274103 0.83589013 553.00 5.06345981e+00 5.72418274e+00 7.64230942e+00 0.84656988 0.76154149 553.25 4.37253977e+00 6.22174316e+00 7.60455074e+00 0.95820454 0.75492161 553.50 4.10211263e+00 6.80042881e+00 7.94186124e+00 1.02801707 0.71672591 553.75 5.31280017e+00 7.06777034e+00 8.84190156e+00 0.92621197 0.72832488 554.00 5.33195649e+00 8.46992032e+00 1.00084619e+01 1.00895562 0.69318542 554.25 5.50397933e+00 9.32101393e+00 1.08247443e+01 1.03739772 0.66347194 554.50 7.83873410e+00 8.82374471e+00 1.18027210e+01 0.84444494 0.57432511 554.75 1.11993507e+01 8.95149926e+00 1.43371823e+01 0.67430624 0.71717568 555.00 1.15838728e+01 4.80048125e+00 1.25391678e+01 0.39286737 0.55152858 555.25 1.19339398e+01 3.96076007e+00 1.25740423e+01 0.32045135 0.43143817 555.50 1.20990286e+01 1.51119841e+00 1.21930396e+01 0.12425895 0.34671547 555.75 1.30463386e+01 7.98958575e-02 1.30465832e+01 0.00612393 0.28460505 556.00 1.04863938e+01 -2.34920195e+00 1.07463112e+01 -0.22038510 0.28223929 556.25 6.91360925e+00 1.29801677e+00 7.03440405e+00 0.18558758 0.16691300 556.50 3.24004476e+00 4.98829251e+00 5.94818898e+00 0.99475170 0.16255802 556.75 4.88732038e-01 4.76676053e+00 4.79174968e+00 1.46862417 0.16487662 557.00 -3.90643525e-01 3.62253735e+00 3.64353938e+00 1.67821820 0.22076113 557.25 2.29425896e-01 2.60584541e+00 2.61592557e+00 1.48297998 0.13803934 557.50 1.71502858e+00 7.77865535e-01 1.88318820e+00 0.42580911 0.09835535 557.75 2.52916960e+00 1.44098711e-01 2.53327127e+00 0.05691318 0.21104973 558.00 2.61550558e+00 -2.18420076e+00 3.40758014e+00 -0.69577820 0.41962155 558.25 2.46396118e+00 -3.34732378e+00 4.15640243e+00 -0.93625148 0.53148187 558.50 1.77068016e+00 -4.97907571e+00 5.28455326e+00 -1.22911984 0.72348044 558.75 7.87106761e-01 -4.95240726e+00 5.01456626e+00 -1.41318046 0.66517949 559.00 -1.15613399e+00 -6.05266184e+00 6.16209065e+00 -1.75953530 0.78317529 559.25 -1.00351111e+00 -5.94922534e+00 6.03326750e+00 -1.73790259 0.76411740 559.50 -1.54829741e+00 -5.13766302e+00 5.36589286e+00 -1.86350237 0.69318415 559.75 -2.41132812e+00 -4.34919764e+00 4.97292906e+00 -2.07703476 0.62460138 560.00 -2.55912620e+00 -3.66650623e+00 4.47128560e+00 -2.18016130 0.65304114 560.25 -2.42644134e+00 -3.07871686e+00 3.91996366e+00 -2.23825989 0.60577386 560.50 -2.45823539e+00 -2.62810232e+00 3.59858903e+00 -2.32281019 0.72830419 560.75 -1.63979407e+00 -2.62185825e+00 3.09242061e+00 -2.12970624 0.65007897 561.00 -6.55088021e-01 -2.49290955e+00 2.57754502e+00 -1.82776706 0.64049439 561.25 -4.34541782e-01 -2.57296422e+00 2.60940059e+00 -1.73810514 0.61018225 561.50 -5.61035643e-04 -2.94903394e+00 2.94903399e+00 -1.57098657 0.70285887 561.75 3.94178093e-01 -2.70059954e+00 2.72921495e+00 -1.42586032 0.67922634 562.00 8.12456340e-01 -2.48437010e+00 2.61384394e+00 -1.25473208 0.78002232 562.25 9.29359400e-01 -2.74412506e+00 2.89722820e+00 -1.24424834 0.81919697 562.50 1.21392661e+00 -2.83414028e+00 3.08317514e+00 -1.16611469 0.82153315 562.75 1.75280179e+00 -2.90439439e+00 3.39231792e+00 -1.02780733 0.84559642 563.00 2.20771974e+00 -3.05441238e+00 3.76874799e+00 -0.94493372 0.88501161 563.25 2.50479319e+00 -2.91534218e+00 3.84359323e+00 -0.86099896 0.91617454 563.50 2.84148926e+00 -2.89615874e+00 4.05731398e+00 -0.79492608 0.93605405 563.75 3.35053372e+00 -3.14865258e+00 4.59783528e+00 -0.75434562 0.91451516 564.00 4.01228069e+00 -3.66558213e+00 5.43460106e+00 -0.74027321 0.94227754 564.25 3.83114781e+00 -4.24161763e+00 5.71568138e+00 -0.83620066 0.96217626 564.50 3.78595956e+00 -4.45000689e+00 5.84260654e+00 -0.86585186 0.97357084 564.75 3.74381736e+00 -4.80472093e+00 6.09110102e+00 -0.90887036 0.97223980 565.00 3.75473865e+00 -5.08914803e+00 6.32435688e+00 -0.93515347 0.97598715 565.25 3.44716295e+00 -5.28337572e+00 6.30848566e+00 -0.99269747 0.97763115 565.50 3.40987726e+00 -5.43864491e+00 6.41919943e+00 -1.01078031 0.97758875 565.75 3.29120378e+00 -5.99159443e+00 6.83602415e+00 -1.06848802 0.97440833 566.00 2.93386870e+00 -6.19508535e+00 6.85468220e+00 -1.12850720 0.97112875 566.25 2.15045027e+00 -6.20666520e+00 6.56864744e+00 -1.23726585 0.95600812 566.50 1.66807619e+00 -6.14293448e+00 6.36538468e+00 -1.30564609 0.96328567 566.75 1.07141069e+00 -6.22322417e+00 6.31477948e+00 -1.40030441 0.96606714 567.00 7.84268870e-01 -6.08995315e+00 6.14024487e+00 -1.44272047 0.96299964 567.25 -1.41796521e-01 -5.38248897e+00 5.38435640e+00 -1.59713428 0.94954531 567.50 -4.71206911e-01 -5.00136705e+00 5.02351553e+00 -1.66473465 0.93055696 567.75 -6.44409566e-01 -3.78628823e+00 3.84073460e+00 -1.73937658 0.92094959 568.00 -5.44004227e-01 -3.42369351e+00 3.46664360e+00 -1.72837297 0.89112127 568.25 -2.26718184e-01 -2.44669017e+00 2.45717193e+00 -1.66319569 0.75496296 568.50 6.31415113e-02 -1.95221188e+00 1.95323272e+00 -1.53846402 0.66970812 568.75 1.29513506e+00 -1.27428039e+00 1.81691093e+00 -0.77728184 0.53597798 569.00 2.01679966e+00 -1.15299188e+00 2.32311669e+00 -0.51934604 0.63102777 569.25 2.83320675e+00 -1.01264410e+00 3.00873870e+00 -0.34326950 0.71883312 569.50 3.36410208e+00 -1.23841901e+00 3.58481024e+00 -0.35273203 0.68841360 569.75 4.53247158e+00 -2.63710432e+00 5.24381710e+00 -0.52694816 0.79773194 570.00 4.62033401e+00 -3.33426789e+00 5.69779157e+00 -0.62510942 0.82996222 570.25 4.91941989e+00 -4.55876019e+00 6.70693570e+00 -0.74736494 0.86225631 570.50 4.57039277e+00 -4.92629755e+00 6.71988821e+00 -0.82285735 0.81678753 570.75 3.97774660e+00 -5.93298769e+00 7.14302533e+00 -0.98018197 0.80189311 571.00 3.29535631e+00 -6.67436361e+00 7.44355445e+00 -1.11217454 0.77865266 571.25 1.49365513e+00 -6.90307323e+00 7.06281995e+00 -1.35770592 0.68523115 571.50 -2.73647901e-01 -6.43624940e+00 6.44206407e+00 -1.61328741 0.67028060 571.75 -1.62957928e+00 -5.37817207e+00 5.61963197e+00 -1.86500197 0.71474836 572.00 -2.07586301e+00 -4.16818060e+00 4.65649404e+00 -2.03286362 0.74986160 572.25 -1.68474997e+00 -3.24194124e+00 3.65356887e+00 -2.05005834 0.73972419 572.50 -7.59555213e-02 -2.67389845e+00 2.67497704e+00 -1.59919497 0.46390359 572.75 1.68564144e+00 -2.83015152e+00 3.29410757e+00 -1.03361757 0.59457913 573.00 2.80994736e+00 -4.28321100e+00 5.12266538e+00 -0.99018847 0.74432703 573.25 3.24156498e+00 -5.75374935e+00 6.60404233e+00 -1.05773630 0.86922617 573.50 2.18066757e+00 -6.50426745e+00 6.86008791e+00 -1.24730630 0.89680317 573.75 1.34307270e+00 -6.67823414e+00 6.81194947e+00 -1.37233181 0.95369821 574.00 1.14947218e+00 -6.76380327e+00 6.86078136e+00 -1.40245997 0.94493778 574.25 1.03673850e+00 -6.79082124e+00 6.86950361e+00 -1.41929849 0.95236570 574.50 5.90569181e-01 -6.49852841e+00 6.52530792e+00 -1.48016790 0.93828430 574.75 5.03292738e-01 -6.48205393e+00 6.50156340e+00 -1.49330777 0.92581108 575.00 1.60669683e-01 -6.50100155e+00 6.50298669e+00 -1.54608675 0.89956117 575.25 1.13707124e-01 -6.43716306e+00 6.43816725e+00 -1.55313400 0.91031927 575.50 1.07280120e+00 -6.43716796e+00 6.52595079e+00 -1.40565674 0.84511732 575.75 2.22222103e+00 -6.86864899e+00 7.21918314e+00 -1.25789364 0.74242545 576.00 2.80039453e+00 -5.80694073e+00 6.44691943e+00 -1.12144965 0.45569423 576.25 2.62765855e+00 -3.57383230e+00 4.43586145e+00 -0.93680254 0.15708357 576.50 -1.52721206e+00 1.31025233e+00 2.01224696e+00 2.43250853 0.05618997 576.75 -2.79825771e+00 1.53693927e+00 3.19255830e+00 2.63932648 0.28172070 577.00 -3.20264871e+00 1.55400290e+00 3.55975895e+00 2.68983534 0.62803202 577.25 -3.42194636e+00 9.70796779e-01 3.55698795e+00 2.86515879 0.74112449 577.50 -3.24256077e+00 2.17092254e-01 3.24981990e+00 3.07474155 0.84362584 577.75 -3.08483749e+00 -1.59354166e-01 3.08895065e+00 -3.08998130 0.85646494 578.00 -2.87202688e+00 -8.08507428e-01 2.98365928e+00 -2.86718326 0.90045900 578.25 -2.86772325e+00 -9.06186333e-01 3.00749236e+00 -2.83552686 0.90468745 578.50 -3.13080977e+00 -1.00380057e+00 3.28779339e+00 -2.83132730 0.94108808 578.75 -3.07804983e+00 -1.03323773e+00 3.24684015e+00 -2.81773218 0.94548050 579.00 -2.93933456e+00 -1.00146827e+00 3.10525785e+00 -2.81321554 0.95388969 579.25 -2.86310304e+00 -9.61231626e-01 3.02015319e+00 -2.81768601 0.95956778 579.50 -2.77262611e+00 -1.01880978e+00 2.95388370e+00 -2.78945489 0.96443449 579.75 -2.84676539e+00 -1.00425986e+00 3.01871017e+00 -2.80245025 0.96634797 580.00 -2.77735209e+00 -9.65353310e-01 2.94033870e+00 -2.80707495 0.96811022 580.25 -2.77492537e+00 -9.01520712e-01 2.91769607e+00 -2.82746833 0.97415838 580.50 -2.82344583e+00 -8.22615618e-01 2.94084050e+00 -2.85808888 0.97933801 580.75 -2.82264305e+00 -6.60709798e-01 2.89893968e+00 -2.91165759 0.97333295 581.00 -2.65593798e+00 -3.49636746e-01 2.67885282e+00 -3.01070189 0.96336430 581.25 -2.41230361e+00 -2.12300093e-01 2.42162756e+00 -3.05381161 0.94944896 581.50 -2.15647818e+00 -6.32712511e-02 2.15740617e+00 -3.11226098 0.92693245 581.75 -1.81776921e+00 4.93307958e-02 1.81843846e+00 3.11446122 0.87264373 582.00 -1.37367375e+00 -4.46181240e-02 1.37439817e+00 -3.10912319 0.84545148 582.25 -1.18390022e+00 -1.68443954e-01 1.19582319e+00 -3.00026238 0.77421664 582.50 -9.92151338e-01 -2.85716436e-01 1.03247187e+00 -2.86120261 0.76132614 582.75 -8.90887481e-01 -5.57311015e-01 1.05084541e+00 -2.58258474 0.77348400 583.00 -8.84043556e-01 -8.27632801e-01 1.21099507e+00 -2.38913900 0.88397098 583.25 -9.39716070e-01 -9.36202854e-01 1.32647732e+00 -2.35806729 0.93071716 583.50 -9.87599309e-01 -9.84492714e-01 1.39448137e+00 -2.35776977 0.95935755 583.75 -1.01494540e+00 -9.72424584e-01 1.40560440e+00 -2.37758675 0.94598763 584.00 -1.02999450e+00 -9.95700682e-01 1.43258805e+00 -2.37312228 0.93940376 584.25 -9.64899763e-01 -1.09836119e+00 1.46199482e+00 -2.29159978 0.94447327 584.50 -9.76207679e-01 -1.15353914e+00 1.51116974e+00 -2.27312201 0.96384465 584.75 -1.05666607e+00 -1.18638669e+00 1.58872796e+00 -2.29842666 0.95061272 585.00 -1.13567612e+00 -1.21000229e+00 1.65947756e+00 -2.32451866 0.96197081 585.25 -1.17815546e+00 -1.11210673e+00 1.62013323e+00 -2.38502544 0.95335188 585.50 -1.22067506e+00 -1.06784405e+00 1.62183184e+00 -2.42287710 0.96391968 585.75 -1.09796081e+00 -9.75070785e-01 1.46842806e+00 -2.41540554 0.95555791 586.00 -1.00966246e+00 -9.07080579e-01 1.35728165e+00 -2.40966233 0.95031094 586.25 -9.46906232e-01 -8.89502468e-01 1.29917129e+00 -2.38744302 0.89722808 586.50 -7.93672301e-01 -9.57629675e-01 1.24377261e+00 -2.26284630 0.83134154 586.75 -5.87904979e-01 -1.41455432e+00 1.53186037e+00 -1.96468799 0.77452668 587.00 -5.55761536e-01 -1.65836878e+00 1.74901627e+00 -1.89415889 0.83323273 587.25 -7.63345463e-01 -1.78497491e+00 1.94134791e+00 -1.97490985 0.89131015 587.50 -9.79524154e-01 -1.91718053e+00 2.15291634e+00 -2.04314101 0.91718498 587.75 -1.27474120e+00 -1.70322892e+00 2.12742894e+00 -2.21328946 0.93747440 588.00 -1.36879731e+00 -1.57085075e+00 2.08354941e+00 -2.28756854 0.95616638 588.25 -1.45910656e+00 -1.40341697e+00 2.02449281e+00 -2.37564676 0.95599080 588.50 -1.41401472e+00 -1.31177405e+00 1.92877909e+00 -2.39368557 0.96676674 588.75 -1.34874412e+00 -1.17308616e+00 1.78752394e+00 -2.42573712 0.97090368 589.00 -1.28876534e+00 -1.08648319e+00 1.68563395e+00 -2.44115201 0.96754750 589.25 -1.22978684e+00 -1.04638963e+00 1.61471574e+00 -2.43659330 0.97067521 589.50 -1.18756268e+00 -1.00920733e+00 1.55846224e+00 -2.43720661 0.97318613 589.75 -1.12851837e+00 -9.53275404e-01 1.47725682e+00 -2.44017533 0.97494040 590.00 -1.07955646e+00 -9.32120487e-01 1.42628565e+00 -2.42935377 0.97203179 590.25 -9.85843461e-01 -8.78328410e-01 1.32035909e+00 -2.41380510 0.96682279 590.50 -9.03050751e-01 -8.94661065e-01 1.27118806e+00 -2.36086133 0.94440019 590.75 -7.02672180e-01 -9.48670171e-01 1.18056058e+00 -2.20831350 0.94759863 591.00 -6.33333247e-01 -9.46596548e-01 1.13892758e+00 -2.16045648 0.95336141 591.25 -6.24350946e-01 -1.05829429e+00 1.22873956e+00 -2.10380052 0.96290528 591.50 -5.61783419e-01 -1.15039055e+00 1.28023398e+00 -2.02507369 0.95074928 591.75 -5.16771168e-01 -1.24102107e+00 1.34431608e+00 -1.96536707 0.96715446 592.00 -5.23493343e-01 -1.37228834e+00 1.46874796e+00 -1.93523137 0.95420613 592.25 -5.58922904e-01 -1.56570389e+00 1.66247510e+00 -1.91367465 0.96551753 592.50 -6.36432778e-01 -1.61253601e+00 1.73358561e+00 -1.94670653 0.95698750 592.75 -7.75712658e-01 -1.76505876e+00 1.92799443e+00 -1.98486966 0.94212892 593.00 -1.09106081e+00 -1.79198808e+00 2.09800738e+00 -2.11770139 0.91935458 593.25 -1.46864775e+00 -1.72384365e+00 2.26463312e+00 -2.27642781 0.95661416 593.50 -1.72847354e+00 -1.41115689e+00 2.23136384e+00 -2.45692061 0.93171688 593.75 -2.02324133e+00 -1.05114392e+00 2.28000198e+00 -2.66243976 0.94556992 594.00 -2.05127593e+00 -5.69690571e-01 2.12891528e+00 -2.87069482 0.89573663 594.25 -2.00670181e+00 3.61268959e-02 2.00702698e+00 3.12359148 0.89958900 594.50 -1.77685182e+00 3.71197163e-01 1.81521065e+00 2.93564732 0.89893553 594.75 -1.52600814e+00 7.29078289e-01 1.69122913e+00 2.69588807 0.88820608 595.00 -9.62754396e-01 9.65875169e-01 1.36374883e+00 2.35457636 0.83587103 595.25 -5.43505702e-01 1.06656781e+00 1.19706530e+00 2.04208157 0.84732204 595.50 -1.49615963e-01 1.09486779e+00 1.10504317e+00 1.70660721 0.84310338 595.75 9.40047975e-02 1.15219394e+00 1.15602240e+00 1.48938899 0.88456938 596.00 4.64183745e-01 1.17450701e+00 1.26290667e+00 1.19442104 0.88541007 596.25 7.42693839e-01 1.13581483e+00 1.35708123e+00 0.99169388 0.89673443 596.50 1.05291892e+00 8.67450817e-01 1.36422475e+00 0.68911740 0.87189088 596.75 1.17852318e+00 7.66673682e-01 1.40595356e+00 0.57675308 0.88366300 597.00 1.23066966e+00 6.55777187e-01 1.39448611e+00 0.48959036 0.86851908 597.25 1.31349207e+00 7.00878951e-01 1.48878901e+00 0.49016467 0.87108851 597.50 1.30088453e+00 8.54515047e-01 1.55643713e+00 0.58119122 0.82447451 597.75 1.24862475e+00 1.13256632e+00 1.68575509e+00 0.73669705 0.80259866 598.00 1.74923016e+00 1.77709622e+00 2.49356715e+00 0.79330029 0.87486034 598.25 2.04148129e+00 2.00165360e+00 2.85906680e+00 0.77554779 0.88369012 598.50 3.43029150e+00 2.75225197e+00 4.39793027e+00 0.67616471 0.86198825 598.75 4.33477586e+00 2.81696347e+00 5.16967746e+00 0.57627129 0.88707657 599.00 6.49916878e+00 1.97225490e+00 6.79183217e+00 0.29463049 0.87700738 599.25 7.35916083e+00 1.08257706e+00 7.43836146e+00 0.14605848 0.89446706 599.50 7.32447350e+00 -7.36182003e-01 7.36137732e+00 -0.10017347 0.89647246 599.75 7.15154134e+00 -1.33930782e+00 7.27587033e+00 -0.18513098 0.88970886 600.00 7.38471937e+00 -2.62240882e+00 7.83652399e+00 -0.34122243 0.90044434 600.25 7.77545502e+00 -3.06382893e+00 8.35731706e+00 -0.37535665 0.90817989 600.50 8.24825981e+00 -3.47878498e+00 8.95185650e+00 -0.39912303 0.91592270 600.75 8.21439272e+00 -4.41015001e+00 9.32339374e+00 -0.49271515 0.86109006 601.00 8.74287262e+00 -6.49204220e+00 1.08896480e+01 -0.63871767 0.89933517 601.25 8.71860809e+00 -6.93543139e+00 1.11406614e+01 -0.67197546 0.89943641 601.50 7.71991998e+00 -8.49274992e+00 1.14771062e+01 -0.83303038 0.93098522 601.75 7.21119968e+00 -9.22833134e+00 1.17116822e+01 -0.90748798 0.91015890 602.00 7.58826721e+00 -1.08075825e+01 1.32055155e+01 -0.95864602 0.85543002 602.25 5.32726076e+00 -1.18509423e+01 1.29932498e+01 -1.14833987 0.81220510 602.50 1.93536463e+00 -1.39748683e+01 1.41082451e+01 -1.43318271 0.90056986 602.75 -1.29101373e-01 -1.34685597e+01 1.34691784e+01 -1.58038142 0.89994972 603.00 -1.30320578e+00 -1.22878601e+01 1.23567735e+01 -1.67645772 0.92116718 603.25 -2.08206061e+00 -1.10115609e+01 1.12066699e+01 -1.75766971 0.93605412 603.50 -2.92969236e+00 -1.08231737e+01 1.12126797e+01 -1.83514837 0.96596855 603.75 -3.29323315e+00 -1.00868582e+01 1.06108479e+01 -1.88637303 0.96307482 604.00 -3.68690262e+00 -9.22241406e+00 9.93207793e+00 -1.95110985 0.97356879 604.25 -3.73953717e+00 -8.30915954e+00 9.11187524e+00 -1.99369182 0.97240765 604.50 -3.73874173e+00 -7.58956478e+00 8.46047772e+00 -2.02851938 0.98113927 604.75 -3.49271822e+00 -7.07283083e+00 7.88822011e+00 -2.02948919 0.98037507 605.00 -3.16491558e+00 -6.79742341e+00 7.49811014e+00 -2.00655148 0.98473484 605.25 -3.00501993e+00 -6.18556016e+00 6.87686697e+00 -2.02302932 0.97559966 605.50 -2.80035586e+00 -5.78427211e+00 6.42649180e+00 -2.02166979 0.97587135 605.75 -2.58093145e+00 -5.59755951e+00 6.16391755e+00 -2.00282737 0.95497091 606.00 -2.56078745e+00 -5.60197973e+00 6.15952995e+00 -1.99955699 0.96613223 606.25 -2.35216567e+00 -5.20100191e+00 5.70816119e+00 -1.99552178 0.95774554 606.50 -2.15993886e+00 -4.88956321e+00 5.34538719e+00 -1.98676401 0.95766375 606.75 -1.93020781e+00 -4.77242568e+00 5.14798495e+00 -1.95513306 0.93252962 607.00 -1.97498659e+00 -4.70036948e+00 5.09843557e+00 -1.96857467 0.93345487 607.25 -1.81449061e+00 -4.01607560e+00 4.40695353e+00 -1.99515184 0.90414870 607.50 -1.64941271e+00 -3.72456913e+00 4.07344786e+00 -1.98768557 0.89829261 607.75 -1.24258234e+00 -3.49301457e+00 3.70744679e+00 -1.91256979 0.84135644 608.00 -6.88951702e-01 -3.22350044e+00 3.29630240e+00 -1.78135619 0.79916683 608.25 4.09954972e-01 -2.98393838e+00 3.01196801e+00 -1.43426386 0.75956837 608.50 1.01338193e+00 -3.11839359e+00 3.27892079e+00 -1.25659227 0.75891904 608.75 2.25078544e+00 -3.59842545e+00 4.24437284e+00 -1.01184347 0.85866638 609.00 2.54608309e+00 -3.90923967e+00 4.66526461e+00 -0.99350861 0.90672368 609.25 3.15546085e+00 -4.95283054e+00 5.87260278e+00 -1.00354137 0.92811135 609.50 3.42661395e+00 -5.35758435e+00 6.35966927e+00 -1.00177980 0.92967508 609.75 3.64355810e+00 -6.11979785e+00 7.12231994e+00 -1.03378650 0.90904556 610.00 3.54112433e+00 -6.63198145e+00 7.51816065e+00 -1.08036162 0.88158678 610.25 2.36579826e+00 -7.17678196e+00 7.55666598e+00 -1.25236794 0.87560110 610.50 2.26681026e+00 -6.89864430e+00 7.26152339e+00 -1.25332283 0.87599004 610.75 2.56079641e+00 -6.88789558e+00 7.34852255e+00 -1.21484979 0.89095506 611.00 2.46454994e+00 -6.78473538e+00 7.21849296e+00 -1.22236728 0.86269832 611.25 2.69803087e+00 -6.72923061e+00 7.24995967e+00 -1.18947818 0.76223209 611.50 2.91075617e+00 -7.02412246e+00 7.60334123e+00 -1.17794300 0.75381671 611.75 2.44834503e+00 -7.85222326e+00 8.22507164e+00 -1.26854678 0.83620786 612.00 2.51459555e+00 -7.85033708e+00 8.24323863e+00 -1.26080595 0.82668039 612.25 2.93089075e+00 -7.81504121e+00 8.34655556e+00 -1.21199758 0.80471055 612.50 3.19277476e+00 -8.22424121e+00 8.82224201e+00 -1.20049043 0.81459555 612.75 4.12636217e+00 -9.15884046e+00 1.00454578e+01 -1.14749904 0.86187459 613.00 3.68308369e+00 -1.01690778e+01 1.08155097e+01 -1.22330811 0.84042676 613.25 2.66825332e+00 -1.18501699e+01 1.21468556e+01 -1.34932405 0.88319385 613.50 1.72951282e+00 -1.23111256e+01 1.24320163e+01 -1.43122599 0.86570785 613.75 1.97657317e+00 -1.34117639e+01 1.35566313e+01 -1.42447354 0.89674038 614.00 1.35522682e+00 -1.34551128e+01 1.35231912e+01 -1.47041280 0.89008317 614.25 3.64611874e-01 -1.45095059e+01 1.45140863e+01 -1.54567244 0.88956464 614.50 -7.43015188e-01 -1.45763284e+01 1.45952534e+01 -1.62172634 0.88955183 614.75 -1.08744628e+00 -1.39455237e+01 1.39878580e+01 -1.64861701 0.92069582 615.00 -2.87672509e+00 -1.33749256e+01 1.36807961e+01 -1.78265225 0.91903520 615.25 -3.98569847e+00 -1.37271337e+01 1.42940544e+01 -1.85337826 0.92936288 615.50 -3.91088112e+00 -1.31198604e+01 1.36903517e+01 -1.86049864 0.90993109 615.75 -5.09789662e+00 -1.33299295e+01 1.42714951e+01 -1.93607362 0.94480734 616.00 -5.33995612e+00 -1.26813000e+01 1.37597420e+01 -1.96934968 0.94143866 616.25 -5.04439568e+00 -1.23535634e+01 1.33437797e+01 -1.95846757 0.95790208 616.50 -5.40387624e+00 -1.26164552e+01 1.37250436e+01 -1.97547542 0.93020807 616.75 -5.59579777e+00 -1.29423325e+01 1.41002455e+01 -1.97888772 0.94175823 617.00 -6.23962043e+00 -1.20031069e+01 1.35280242e+01 -2.05018477 0.93878120 617.25 -7.21300700e+00 -1.12005456e+01 1.33221504e+01 -2.14293294 0.94881369 617.50 -8.12324863e+00 -1.09637676e+01 1.36451958e+01 -2.20845933 0.93395910 617.75 -9.06958512e+00 -1.07020409e+01 1.40282235e+01 -2.27381576 0.92310575 618.00 -1.08225764e+01 -8.52785202e+00 1.37786944e+01 -2.47423101 0.89884341 618.25 -1.08915502e+01 -6.70001389e+00 1.27873395e+01 -2.59010275 0.89855837 618.50 -1.08649364e+01 -4.18387161e+00 1.16426640e+01 -2.77401399 0.90737079 618.75 -9.86529165e+00 -3.86283892e+00 1.05945979e+01 -2.76838454 0.87506825 619.00 -8.41529806e+00 -2.07170490e+00 8.66655657e+00 -2.90020950 0.87001148 619.25 -7.86803964e+00 -1.57940273e+00 8.02499600e+00 -2.94348902 0.87908804 619.50 -6.92917462e+00 -1.13065182e+00 7.02081437e+00 -2.97984547 0.87464966 619.75 -6.55775279e+00 -4.52729996e-01 6.57336186e+00 -3.07266465 0.88161720 620.00 -5.62310681e+00 -5.83183421e-03 5.62310984e+00 -3.14055553 0.87874537 620.25 -4.72225749e+00 2.05307272e-01 4.72671841e+00 3.09814351 0.84763957 620.50 -3.74954245e+00 7.27879073e-02 3.75024888e+00 3.12218261 0.89951719 620.75 -3.30491196e+00 -6.80233510e-02 3.30561193e+00 -3.12101306 0.85595918 621.00 -2.31144985e+00 -7.23618131e-01 2.42207011e+00 -2.83819941 0.73682797 621.25 -2.02896658e+00 -9.73652504e-01 2.25048985e+00 -2.69417341 0.65053479 621.50 -1.90644785e+00 -1.66520302e+00 2.53129305e+00 -2.42363640 0.75383349 621.75 -2.03063843e+00 -1.99903781e+00 2.84949901e+00 -2.36403630 0.68964277 622.00 -3.00087170e+00 -2.63783921e+00 3.99542571e+00 -2.42048793 0.79827352 622.25 -3.56896682e+00 -2.20360318e+00 4.19444766e+00 -2.58845222 0.75757442 622.50 -4.61363108e+00 -1.52646378e+00 4.85959704e+00 -2.82207018 0.75448709 622.75 -5.60096608e+00 -7.13607569e-01 5.64624271e+00 -3.01486747 0.75474210 623.00 -6.07123022e+00 9.88098656e-01 6.15111171e+00 2.98025624 0.78095944 623.25 -5.87584243e+00 1.92297826e+00 6.18250513e+00 2.82531033 0.76728780 623.50 -5.24105160e+00 3.21190592e+00 6.14694733e+00 2.59178823 0.72868730 623.75 -5.01793522e+00 4.40637630e+00 6.67801063e+00 2.42099526 0.69650602 624.00 -3.29663510e+00 6.72662763e+00 7.49101610e+00 2.02648241 0.71879833 624.25 -1.18118487e+00 8.02112140e+00 8.10762519e+00 1.71700483 0.68817321 624.50 2.58738043e+00 9.49164118e+00 9.83797691e+00 1.30466676 0.80495078 624.75 5.63661471e+00 7.20714609e+00 9.14955628e+00 0.90707383 0.79760900 625.00 7.35725808e+00 5.49805509e+00 9.18465330e+00 0.64176879 0.89442737 625.25 7.64615039e+00 2.76839524e+00 8.13188957e+00 0.34738151 0.86873192 625.50 7.37749188e+00 1.01754018e+00 7.44733338e+00 0.13706020 0.91479154 625.75 6.68478743e+00 -1.36282330e-01 6.68617647e+00 -0.02038411 0.89941261 626.00 6.25077331e+00 -7.67175411e-01 6.29767617e+00 -0.12212213 0.94745879 626.25 5.81118532e+00 -1.44090301e+00 5.98715928e+00 -0.24305150 0.91634936 626.50 5.30987896e+00 -2.07573396e+00 5.70118286e+00 -0.37265373 0.89193505 626.75 4.95564944e+00 -2.45404927e+00 5.52999269e+00 -0.45980213 0.92552678 627.00 4.76296926e+00 -2.82435528e+00 5.53740544e+00 -0.53524326 0.93742907 627.25 4.02825618e+00 -3.50954428e+00 5.34263502e+00 -0.71669172 0.89139386 627.50 3.56051921e+00 -3.88392127e+00 5.26897917e+00 -0.82881296 0.87901937 627.75 2.92726815e+00 -4.36568835e+00 5.25624710e+00 -0.98013286 0.81905051 628.00 2.10801281e+00 -4.50699609e+00 4.97561371e+00 -1.13330444 0.80131959 628.25 7.78498241e-01 -3.96711900e+00 4.04278278e+00 -1.37702098 0.81027736 628.50 5.32454344e-01 -3.62626733e+00 3.66514971e+00 -1.42500549 0.81277225 628.75 3.30861355e-01 -3.04427957e+00 3.06220628e+00 -1.46253827 0.69956857 629.00 -1.72255661e-02 -2.79316201e+00 2.79321512e+00 -1.57696330 0.71978976 629.25 -1.42413008e-01 -2.15892560e+00 2.16361762e+00 -1.63666566 0.61499684 629.50 -1.52293767e-01 -1.90190367e+00 1.90799134e+00 -1.65070022 0.60214316 629.75 -1.58923392e-01 -1.55503657e+00 1.56313639e+00 -1.67264186 0.56385916 630.00 -4.46752515e-02 -1.33493731e+00 1.33568466e+00 -1.60425002 0.52106061 630.25 2.98434650e-01 -1.14079275e+00 1.17918249e+00 -1.31492749 0.53744814 630.50 4.91176514e-01 -1.14360149e+00 1.24461992e+00 -1.16512056 0.64312564 630.75 5.01365178e-01 -1.09987399e+00 1.20875549e+00 -1.14309752 0.68956811 631.00 4.27443551e-01 -1.14987269e+00 1.22674985e+00 -1.21489453 0.71876090 631.25 3.36832578e-01 -1.10234252e+00 1.15265572e+00 -1.27424579 0.74335495 631.50 3.96503639e-01 -1.01158018e+00 1.08651258e+00 -1.19723614 0.68560699 631.75 3.80288825e-01 -8.34183963e-01 9.16778313e-01 -1.14306233 0.72075580 632.00 3.82152759e-01 -7.68298902e-01 8.58093197e-01 -1.10922996 0.74961480 632.25 4.69222163e-01 -6.25412246e-01 7.81863105e-01 -0.92712846 0.77853660 632.50 6.22504573e-01 -5.80653328e-01 8.51275649e-01 -0.75062768 0.82116867 632.75 7.48562935e-01 -5.23935211e-01 9.13703767e-01 -0.61067320 0.87008373 633.00 7.88159735e-01 -5.43853635e-01 9.57586834e-01 -0.60400311 0.91627591 633.25 8.77606487e-01 -5.46237330e-01 1.03371581e+00 -0.55673983 0.96480487 633.50 9.26910662e-01 -5.68981327e-01 1.08761350e+00 -0.55053895 0.97011453 633.75 9.78432867e-01 -5.99521720e-01 1.14750040e+00 -0.54973212 0.97786941 634.00 1.00859886e+00 -6.25993886e-01 1.18707203e+00 -0.55547012 0.97632232 634.25 1.05559119e+00 -6.19043009e-01 1.22371852e+00 -0.53039073 0.98418714 634.50 1.07895323e+00 -6.12136368e-01 1.24050433e+00 -0.51606067 0.97981734 634.75 1.12279426e+00 -6.13577827e-01 1.27950955e+00 -0.50013205 0.98772122 635.00 1.16034197e+00 -5.91532037e-01 1.30242222e+00 -0.47144979 0.98205104 635.25 1.21356370e+00 -6.06826952e-01 1.35682564e+00 -0.46367734 0.98090517 635.50 1.31034853e+00 -5.61663839e-01 1.42565057e+00 -0.40494717 0.96318988 635.75 1.47572743e+00 -5.33085678e-01 1.56906080e+00 -0.34664922 0.97331971 636.00 1.64168628e+00 -6.27626094e-01 1.75756887e+00 -0.36516027 0.96916989 636.25 1.77130401e+00 -7.20065767e-01 1.91207024e+00 -0.38611210 0.97682320 636.50 1.89969547e+00 -9.16161940e-01 2.10907458e+00 -0.44936148 0.96234194 636.75 2.02041510e+00 -1.07979889e+00 2.29086071e+00 -0.49082169 0.96790832 637.00 2.10895133e+00 -1.28855948e+00 2.47144922e+00 -0.54846512 0.95892290 637.25 2.17510455e+00 -1.57341372e+00 2.68453171e+00 -0.62624147 0.96643994 637.50 2.10033371e+00 -1.84548204e+00 2.79592662e+00 -0.72089992 0.92742346 637.75 2.03879478e+00 -2.18961816e+00 2.99184088e+00 -0.82105208 0.92772384 638.00 1.65983866e+00 -2.47375880e+00 2.97901779e+00 -0.97981463 0.90909053 638.25 1.42175741e+00 -2.50867176e+00 2.88354437e+00 -1.05519399 0.90104757 638.50 8.06436918e-01 -2.81260303e+00 2.92593170e+00 -1.29156468 0.89814926 638.75 6.81438383e-01 -3.01177680e+00 3.08790508e+00 -1.34828489 0.90180364 639.00 4.22512448e-01 -2.86879090e+00 2.89973757e+00 -1.42456863 0.91145244 639.25 4.46202947e-01 -2.84144575e+00 2.87626685e+00 -1.41503458 0.91795202 639.50 4.75039392e-01 -2.74069182e+00 2.78155605e+00 -1.39917317 0.84025438 639.75 4.30155008e-01 -3.03690329e+00 3.06721615e+00 -1.43008968 0.81522786 640.00 1.66798114e-01 -3.10624660e+00 3.11072171e+00 -1.51715021 0.77362560 640.25 -1.51079233e-01 -2.97121249e+00 2.97505103e+00 -1.62160024 0.60177645 640.50 -2.10819000e+00 -1.98865842e+00 2.89814206e+00 -2.38536269 0.45504991 640.75 -2.64436929e+00 -4.50482016e-01 2.68246584e+00 -2.97285731 0.44905319 641.00 -2.13691800e+00 3.21486199e-01 2.16096550e+00 2.99226864 0.58494385 641.25 -1.67888712e+00 4.80296646e-01 1.74623791e+00 2.86295457 0.60319550 641.50 -1.08936546e+00 3.93994696e-01 1.15842519e+00 2.79455630 0.63458292 641.75 -7.66011974e-01 3.88747615e-01 8.59010508e-01 2.67196666 0.58847505 642.00 -4.99945538e-01 1.62163040e-01 5.25587664e-01 2.82793845 0.50892072 642.25 -3.77917933e-01 1.86113449e-02 3.78375932e-01 3.09238535 0.39488398 642.50 -2.59155796e-01 -9.10280441e-02 2.74677686e-01 -2.80380616 0.40774298 642.75 -2.31170066e-01 -2.01806725e-01 3.06864064e-01 -2.42390816 0.50245780 643.00 -1.84734056e-01 -2.79390664e-01 3.34941509e-01 -2.15500713 0.60823460 643.25 -1.76761006e-01 -2.88384957e-01 3.38245971e-01 -2.12067203 0.57686624 643.50 -1.25158151e-01 -3.67546364e-01 3.88271674e-01 -1.89900396 0.72172735 643.75 -7.28745005e-02 -4.02630850e-01 4.09172695e-01 -1.74985366 0.73641294 644.00 -2.53325523e-02 -4.26827983e-01 4.27579075e-01 -1.63007752 0.72706069 644.25 -5.49237179e-02 -5.39263281e-01 5.42053043e-01 -1.67229587 0.80811547 644.50 -9.05233134e-02 -6.36029101e-01 6.42438704e-01 -1.71217257 0.90819260 644.75 -8.32385536e-02 -6.76809536e-01 6.81908941e-01 -1.69316848 0.90281694 645.00 -9.89069879e-02 -7.28141463e-01 7.34828267e-01 -1.70580487 0.91725057 645.25 -1.71940287e-01 -7.42910578e-01 7.62548090e-01 -1.79823329 0.91709168 645.50 -2.47199696e-01 -7.40406399e-01 7.80582683e-01 -1.89303006 0.94736639 645.75 -2.98122038e-01 -7.42598727e-01 8.00205985e-01 -1.95255878 0.94460598 646.00 -3.47940184e-01 -7.09826573e-01 7.90516373e-01 -2.02655416 0.95021543 646.25 -4.14615686e-01 -6.83117809e-01 7.99097058e-01 -2.11630760 0.95031130 646.50 -4.56151556e-01 -6.40579723e-01 7.86394700e-01 -2.18959157 0.95776957 646.75 -4.28208598e-01 -5.70339946e-01 7.13197208e-01 -2.21480629 0.94991081 647.00 -4.18941357e-01 -5.53785674e-01 6.94399333e-01 -2.21844734 0.96511891 647.25 -3.73964714e-01 -5.45694808e-01 6.61537929e-01 -2.17158832 0.96904751 647.50 -3.71663519e-01 -5.60002091e-01 6.72113170e-01 -2.15673004 0.97977203 647.75 -3.85019115e-01 -5.67158195e-01 6.85498459e-01 -2.16719074 0.97640914 648.00 -3.81288035e-01 -5.67026991e-01 6.83300940e-01 -2.16278084 0.98173752 648.25 -3.76308863e-01 -5.74265079e-01 6.86577557e-01 -2.15087978 0.97980025 648.50 -3.65051226e-01 -5.69087579e-01 6.76108771e-01 -2.14114995 0.98178746 648.75 -3.33930255e-01 -5.80313765e-01 6.69532285e-01 -2.09295410 0.98314999 649.00 -3.17073165e-01 -6.08675423e-01 6.86309816e-01 -2.05104207 0.98506630 649.25 -3.15896063e-01 -6.93636187e-01 7.62182054e-01 -1.99814870 0.97802159 649.50 -3.25197688e-01 -7.49862114e-01 8.17341254e-01 -1.97999316 0.98065686 649.75 -3.28806480e-01 -8.48549571e-01 9.10027514e-01 -1.94047398 0.98269067 650.00 -3.52415984e-01 -8.98967573e-01 9.65577404e-01 -1.94440714 0.98171123 650.25 -4.63908595e-01 -1.02494598e+00 1.12504465e+00 -1.99582492 0.98450825 650.50 -5.28100744e-01 -1.08560873e+00 1.20724344e+00 -2.02355004 0.98656704 650.75 -7.00512413e-01 -1.08875194e+00 1.29464220e+00 -2.14252394 0.98667291 651.00 -7.76926466e-01 -1.09121606e+00 1.33953993e+00 -2.18951888 0.98882727 651.25 -8.64630391e-01 -1.10606283e+00 1.40390907e+00 -2.23429053 0.98675349 651.50 -9.20201781e-01 -1.08813998e+00 1.42506840e+00 -2.27276825 0.98646580 651.75 -1.03880136e+00 -1.03496883e+00 1.46637947e+00 -2.35804259 0.98165571 652.00 -1.07602864e+00 -1.01572852e+00 1.47971012e+00 -2.38501400 0.98008995 652.25 -1.14988020e+00 -1.01020184e+00 1.53059865e+00 -2.42076804 0.97620072 652.50 -1.22650752e+00 -1.00017875e+00 1.58261752e+00 -2.45749037 0.97975901 652.75 -1.30591808e+00 -1.00790709e+00 1.64963594e+00 -2.48428514 0.98810669 653.00 -1.32365688e+00 -9.85436546e-01 1.65019778e+00 -2.50163348 0.98571846 653.25 -1.39345498e+00 -9.30185385e-01 1.67539895e+00 -2.55298645 0.98102835 653.50 -1.39017956e+00 -9.53798717e-01 1.68592147e+00 -2.54025830 0.97647730 653.75 -1.42083689e+00 -1.00246039e+00 1.73888019e+00 -2.52715677 0.98197274 654.00 -1.45347939e+00 -9.74337313e-01 1.74983872e+00 -2.55104562 0.97877014 654.25 -1.52165764e+00 -9.39009327e-01 1.78806613e+00 -2.58869708 0.97969837 654.50 -1.55502071e+00 -8.99292006e-01 1.79633391e+00 -2.61727053 0.97168725 654.75 -1.61444002e+00 -8.88327984e-01 1.84269997e+00 -2.63856591 0.97733446 655.00 -1.65133044e+00 -8.73968972e-01 1.86834526e+00 -2.65481868 0.96817683 655.25 -1.68718135e+00 -7.94419774e-01 1.86485487e+00 -2.70153072 0.97309142 655.50 -1.69308202e+00 -7.65593479e-01 1.85813350e+00 -2.71691964 0.97072206 655.75 -1.66666420e+00 -7.64469347e-01 1.83362563e+00 -2.71154204 0.97520552 656.00 -1.58297290e+00 -7.62529806e-01 1.75705860e+00 -2.69268590 0.96601866 656.25 -1.52051190e+00 -7.49053480e-01 1.69500370e+00 -2.68385645 0.96465152 656.50 -1.39709826e+00 -7.99251562e-01 1.60956100e+00 -2.62195582 0.94625216 656.75 -1.31296110e+00 -8.59737265e-01 1.56939957e+00 -2.56184498 0.95635572 657.00 -1.18106032e+00 -1.08379711e+00 1.60297213e+00 -2.39911264 0.92030970 657.25 -1.08363169e+00 -1.39032880e+00 1.76274553e+00 -2.23285369 0.94815110 657.50 -1.20899395e+00 -1.66059609e+00 2.05408027e+00 -2.20009961 0.95913309 657.75 -1.36416584e+00 -1.85106771e+00 2.29943473e+00 -2.20590051 0.97001667 658.00 -1.67963285e+00 -1.97882025e+00 2.59555314e+00 -2.27459632 0.96931970 658.25 -1.89121282e+00 -1.95125284e+00 2.71736519e+00 -2.34057037 0.98114067 658.50 -2.02934764e+00 -1.84348807e+00 2.74166010e+00 -2.40414826 0.98032634 658.75 -2.07734538e+00 -1.77697958e+00 2.73368255e+00 -2.43396685 0.98030802 659.00 -1.93983769e+00 -1.65791113e+00 2.55179145e+00 -2.43439662 0.97562130 659.25 -1.85558099e+00 -1.66079421e+00 2.49026469e+00 -2.41153213 0.97611726 659.50 -1.68969153e+00 -1.57494741e+00 2.30987376e+00 -2.39132759 0.96402870 659.75 -1.66551497e+00 -1.59817592e+00 2.30826914e+00 -2.37682435 0.96353741 660.00 -1.60649582e+00 -1.78730131e+00 2.40318014e+00 -2.30296953 0.93523039 660.25 -1.67676828e+00 -2.08564165e+00 2.67608911e+00 -2.24794603 0.93427846 660.50 -1.77640780e+00 -2.23675064e+00 2.85633998e+00 -2.24198530 0.96942359 660.75 -1.85838307e+00 -2.32613371e+00 2.97732861e+00 -2.24487532 0.96557651 661.00 -2.41859841e+00 -2.45656325e+00 3.44736440e+00 -2.34840725 0.94684778 661.25 -2.85317055e+00 -2.28614058e+00 3.65609367e+00 -2.46608194 0.95438711 661.50 -3.16930723e+00 -1.85989862e+00 3.67474233e+00 -2.61090058 0.97271101 661.75 -3.23862938e+00 -1.51157685e+00 3.57401523e+00 -2.70491061 0.97325959 662.00 -3.07240580e+00 -9.52442905e-01 3.21664808e+00 -2.84098784 0.98260443 662.25 -2.89807596e+00 -7.76861880e-01 3.00039308e+00 -2.87968871 0.97626809 662.50 -2.56611487e+00 -6.12728994e-01 2.63825366e+00 -2.90720447 0.97356710 662.75 -2.46312176e+00 -6.00393095e-01 2.53523977e+00 -2.90250219 0.97059673 663.00 -2.29139327e+00 -4.87457505e-01 2.34266898e+00 -2.93198328 0.95929531 663.25 -2.26629996e+00 -4.30208674e-01 2.30677156e+00 -2.95399609 0.95473672 663.50 -2.32100712e+00 -2.88019455e-01 2.33880937e+00 -3.01813135 0.95494243 663.75 -2.36413519e+00 -1.06838371e-01 2.36654804e+00 -3.09643207 0.93773383 664.00 -2.36711243e+00 2.81983310e-01 2.38384896e+00 3.02302596 0.93783436 664.25 -2.24556944e+00 6.00005010e-01 2.32434681e+00 2.88049703 0.90213526 664.50 -1.83714610e+00 1.14919497e+00 2.16696905e+00 2.58261036 0.86069712 664.75 -1.35625907e+00 1.35481574e+00 1.91701965e+00 2.35672687 0.73072310 665.00 -4.05872377e-01 1.39921804e+00 1.45689516e+00 1.85311911 0.66303061 665.25 2.17522502e-01 1.35451378e+00 1.37186866e+00 1.41156503 0.64810979 665.50 6.53768694e-01 1.06723770e+00 1.25156295e+00 1.02117799 0.65057859 665.75 1.03075325e+00 6.91239345e-01 1.24107377e+00 0.59073159 0.58790128 666.00 1.38950666e+00 2.20807234e-01 1.40694157e+00 0.15759280 0.69416930 666.25 1.46961827e+00 -2.98448926e-01 1.49961649e+00 -0.20035458 0.68487501 666.50 1.52387049e+00 -9.20006291e-01 1.78005417e+00 -0.54315762 0.80343658 666.75 1.17300194e+00 -1.43540571e+00 1.85373221e+00 -0.88566007 0.79037822 667.00 7.54232425e-01 -1.83694545e+00 1.98575808e+00 -1.18119364 0.84771131 667.25 2.32785386e-01 -1.87929040e+00 1.89365294e+00 -1.44755532 0.84640801 667.50 -6.33534845e-02 -1.78576773e+00 1.78689117e+00 -1.60625834 0.88835188 667.75 -4.19941068e-01 -1.45483358e+00 1.51422959e+00 -1.85181016 0.84692992 668.00 -6.05489175e-01 -1.28358166e+00 1.41922479e+00 -2.01156383 0.89987696 668.25 -7.66583372e-01 -9.00776920e-01 1.18281407e+00 -2.27588496 0.84226662 668.50 -8.05984775e-01 -7.41794493e-01 1.09538602e+00 -2.39764324 0.85364265 668.75 -6.17228597e-01 -4.16290008e-01 7.44492117e-01 -2.54822073 0.65203177 669.00 -4.88461045e-01 -1.23800221e-01 5.03905435e-01 -2.89337002 0.43987633 669.25 -8.76285288e-02 2.78455579e-01 2.91918257e-01 1.87567950 0.14808463 669.50 2.74741331e-01 3.36521572e-01 4.34430164e-01 0.88612595 0.22476509 669.75 1.17143264e+00 2.76243328e-01 1.20356338e+00 0.23158574 0.65608218 670.00 1.58640282e+00 3.30107554e-02 1.58674624e+00 0.02080556 0.76313322 670.25 1.78205325e+00 -7.23076494e-01 1.92316234e+00 -0.38545747 0.75780493 670.50 1.71039908e+00 -1.36385727e+00 2.18759495e+00 -0.67314822 0.73114898 670.75 1.14187375e+00 -2.28079257e+00 2.55066470e+00 -1.10663062 0.82034643 671.00 8.52427752e-01 -2.37987140e+00 2.52792819e+00 -1.22685085 0.84311191 671.25 2.56254428e-01 -2.09993503e+00 2.11551258e+00 -1.44936700 0.79796633 671.50 -7.54561756e-02 -2.05370310e+00 2.05508882e+00 -1.60752133 0.81111009 671.75 -3.10516450e-01 -1.98469730e+00 2.00884142e+00 -1.72599349 0.87244808 672.00 -4.46542569e-01 -1.90515923e+00 1.95679124e+00 -1.80102630 0.83050663 672.25 -9.11571834e-01 -1.88379654e+00 2.09276196e+00 -2.02148233 0.74419892 672.50 -1.09084774e+00 -1.83475149e+00 2.13454019e+00 -2.10719732 0.78287155 672.75 -1.07731539e+00 -1.49894858e+00 1.84592938e+00 -2.19397194 0.78153150 673.00 -1.28667393e+00 -1.21486765e+00 1.76958560e+00 -2.38489142 0.78178650 673.25 -1.36914593e+00 -7.88215545e-01 1.57982415e+00 -2.61923343 0.83337981 673.50 -1.31831999e+00 -5.45481581e-01 1.42671572e+00 -2.74927203 0.81495661 673.75 -1.12444476e+00 -4.81433911e-02 1.12547492e+00 -3.09880353 0.79865688 674.00 -8.83700579e-01 1.06492258e-01 8.90093992e-01 3.02166379 0.72012784 674.25 -4.90180383e-01 2.79408574e-01 5.64221551e-01 2.62351526 0.60596940 674.50 -2.74608457e-01 3.18787341e-01 4.20755480e-01 2.28188064 0.43377853 674.75 -1.36492483e-02 2.55422209e-01 2.55786643e-01 1.62418353 0.26880536 675.00 1.25183417e-01 2.07158665e-01 2.42044625e-01 1.02723013 0.27596189 675.25 2.58179515e-01 2.28571519e-01 3.44821115e-01 0.72464522 0.60537029 675.50 2.80396516e-01 1.63379577e-01 3.24522869e-01 0.52758188 0.49438218 675.75 4.30555782e-01 4.20181793e-02 4.32601212e-01 0.09728250 0.67428711 676.00 5.17397794e-01 -8.49078785e-03 5.17467459e-01 -0.01640909 0.69393038 676.25 6.03156693e-01 -7.45941228e-02 6.07751824e-01 -0.12304807 0.81727205 676.50 6.68150413e-01 -1.04883206e-01 6.76332360e-01 -0.15570482 0.85632434 676.75 7.48363192e-01 -1.53724649e-01 7.63988701e-01 -0.20259635 0.90502598 677.00 7.98997343e-01 -1.54516370e-01 8.13800997e-01 -0.19102970 0.87616164 677.25 8.86235423e-01 -1.40298788e-01 8.97271963e-01 -0.15700576 0.90069839 677.50 9.33530085e-01 -1.42420063e-01 9.44331454e-01 -0.15139342 0.80267081 677.75 1.08469748e+00 -1.75395605e-01 1.09878672e+00 -0.16031241 0.80259789 678.00 1.12143680e+00 -1.87207327e-01 1.13695517e+00 -0.16540999 0.77400427 678.25 1.18025985e+00 -2.36654398e-01 1.20375189e+00 -0.19788630 0.77220077 678.50 1.44652568e+00 -2.94615723e-01 1.47622321e+00 -0.20092312 0.77392611 678.75 1.55342247e+00 -2.99432214e-01 1.58201803e+00 -0.19042101 0.74826783 679.00 1.91789135e+00 -2.90774990e-01 1.93980858e+00 -0.15046592 0.71631297 679.25 2.22926353e+00 -3.02849100e-01 2.24974075e+00 -0.13502503 0.75689999 679.50 1.92765522e+00 -3.70063617e-01 1.96285550e+00 -0.18966844 0.52847633 679.75 1.92257387e+00 -2.53976571e-01 1.93927677e+00 -0.13134188 0.34191459 680.00 1.57886926e+00 -8.23665630e-01 1.78080129e+00 -0.48084135 0.17634045 680.25 8.34070505e-01 -1.30138042e+00 1.54572462e+00 -1.00083632 0.12063011 680.50 -3.61156601e-01 -1.51696420e+00 1.55936349e+00 -1.80452369 0.16546583 680.75 -9.46720127e-01 -1.64739068e+00 1.90004607e+00 -2.09238901 0.29937078 681.00 -1.12354131e+00 -2.30550057e+00 2.56469842e+00 -2.02425726 0.40923060 681.25 -1.13639560e+00 -2.47953633e+00 2.72754384e+00 -2.00053909 0.49759945 681.50 -1.19268100e+00 -1.46355865e+00 1.88798620e+00 -2.25456794 0.46471655 681.75 -1.47847078e+00 -1.17190273e+00 1.88659265e+00 -2.47135248 0.48172404 682.00 -1.29986475e+00 -6.47823728e-01 1.45235118e+00 -2.67924365 0.37628421 682.25 -1.02874798e+00 -3.24361630e-01 1.07867181e+00 -2.83616124 0.31161384 682.50 -8.14057404e-01 6.35141424e-02 8.16531385e-01 3.06372869 0.33601278 682.75 -6.84331301e-01 3.83961341e-02 6.85407610e-01 3.08554390 0.32245168 683.00 -3.81427525e-01 -6.62010649e-02 3.87129872e-01 -2.96974326 0.16094166 683.25 -1.98162782e-01 -2.81311296e-01 3.44099598e-01 -2.18448609 0.10881373 683.50 -2.07612776e-01 -8.01568527e-01 8.28018821e-01 -1.82423511 0.42732689 683.75 -3.71059725e-01 -9.65827875e-01 1.03465395e+00 -1.93759802 0.45955118 684.00 -6.75231686e-01 -1.27410528e+00 1.44197160e+00 -2.05812788 0.64486339 684.25 -8.10388660e-01 -1.21571745e+00 1.46106081e+00 -2.15874788 0.65138844 684.50 -1.26821221e+00 -9.22112132e-01 1.56800924e+00 -2.51291191 0.71072024 684.75 -1.31982614e+00 -8.08041850e-01 1.54753761e+00 -2.59222642 0.73385181 685.00 -1.21502495e+00 -5.72487482e-01 1.34314093e+00 -2.70127108 0.69632939 685.25 -1.09732231e+00 -5.87799947e-01 1.24483936e+00 -2.64981980 0.74557876 685.50 -1.00492095e+00 -6.20609848e-01 1.18111079e+00 -2.58835352 0.84779360 685.75 -1.03372865e+00 -5.61854326e-01 1.17655225e+00 -2.64373651 0.84990814 686.00 -1.20178692e+00 -6.15296307e-01 1.35014123e+00 -2.66840345 0.88456067 686.25 -1.20619981e+00 -5.86002574e-01 1.34101342e+00 -2.68934884 0.85634247 686.50 -1.28896015e+00 -4.30392547e-01 1.35891723e+00 -2.81932608 0.86445626 686.75 -1.30481731e+00 -3.14977252e-01 1.34229612e+00 -2.90472843 0.80674637 687.00 -1.29668788e+00 -2.15316797e-01 1.31444315e+00 -2.97704270 0.80047795 687.25 -1.31230127e+00 1.61976453e-02 1.31240123e+00 3.12925035 0.82940956 687.50 -1.33845662e+00 1.61584756e-01 1.34817498e+00 3.02144939 0.86582871 687.75 -1.08258645e+00 3.45090100e-01 1.13625728e+00 2.83301087 0.81090459 688.00 -9.03848783e-01 4.83825440e-01 1.02519739e+00 2.65010958 0.81087464 688.25 -6.06926537e-01 4.83515188e-01 7.75981159e-01 2.46889052 0.69282732 688.50 -3.56403353e-01 4.48947192e-01 5.73216304e-01 2.24178505 0.66242641 688.75 -2.04825118e-01 2.62541781e-01 3.32988762e-01 2.23332333 0.45707141 689.00 -1.20325180e-01 1.43893302e-01 1.87572470e-01 2.26723057 0.24958696 689.25 -7.50015019e-02 -3.10904000e-02 8.11901364e-02 -2.74862319 0.05963420 689.50 -4.49789778e-02 -1.20477894e-01 1.28600278e-01 -1.92810912 0.21514731 689.75 -7.63504238e-02 -1.86932953e-01 2.01924036e-01 -1.95855516 0.44868146 690.00 -1.11922739e-01 -2.51596760e-01 2.75368170e-01 -1.98935900 0.66168923 690.25 -1.44788775e-01 -3.46010274e-01 3.75082523e-01 -1.96710792 0.83669058 690.50 -1.67660711e-01 -3.88912667e-01 4.23512900e-01 -1.97782336 0.89666202 690.75 -2.20397735e-01 -4.35219151e-01 4.87843081e-01 -2.03955586 0.91559114 691.00 -2.63159632e-01 -4.41864747e-01 5.14293153e-01 -2.10794917 0.93539349 691.25 -3.08747144e-01 -4.43838837e-01 5.40664140e-01 -2.17858267 0.93525704 691.50 -3.29966909e-01 -4.22604412e-01 5.36164760e-01 -2.23371597 0.94084115 691.75 -3.28892714e-01 -3.78313506e-01 5.01289862e-01 -2.28642619 0.93447135 692.00 -3.24976329e-01 -3.58423712e-01 4.83815225e-01 -2.30729090 0.90587065 692.25 -3.26520091e-01 -3.67921373e-01 4.91916158e-01 -2.29664687 0.91795000 692.50 -3.16704982e-01 -3.93464763e-01 5.05090651e-01 -2.24852595 0.93441391 692.75 -3.05913402e-01 -3.77053709e-01 4.85543519e-01 -2.25240519 0.92122484 693.00 -3.36352573e-01 -3.76816308e-01 5.05097597e-01 -2.29951731 0.94289083 693.25 -3.57898250e-01 -4.10791023e-01 5.44830636e-01 -2.28749374 0.95361333 693.50 -3.79523134e-01 -4.02222091e-01 5.53010325e-01 -2.32716639 0.94324660 693.75 -4.32573821e-01 -3.50667567e-01 5.56855325e-01 -2.46038923 0.94812238 694.00 -4.44086765e-01 -3.07979530e-01 5.40429872e-01 -2.53523429 0.94142774 694.25 -4.38259724e-01 -2.01864924e-01 4.82515319e-01 -2.70995412 0.93965180 694.50 -4.08704917e-01 -1.48183706e-01 4.34739140e-01 -2.79376474 0.93417542 694.75 -3.29958181e-01 -1.10881372e-01 3.48090620e-01 -2.81740202 0.92574086 695.00 -2.72674378e-01 -9.88563896e-02 2.90041208e-01 -2.79378700 0.87949236 695.25 -1.77899527e-01 -1.11874022e-01 2.10152417e-01 -2.58022191 0.80688333 695.50 -1.28916430e-01 -1.33683807e-01 1.85717006e-01 -2.33804198 0.75439282 695.75 -8.69178624e-02 -2.26433838e-01 2.42542775e-01 -1.93730799 0.77367979 696.00 -8.49654851e-02 -2.79467946e-01 2.92098385e-01 -1.86594247 0.84766399 696.25 -1.05160543e-01 -3.27107048e-01 3.43595344e-01 -1.88184723 0.90143039 696.50 -1.53091530e-01 -3.49444015e-01 3.81507715e-01 -1.98371052 0.89891434 696.75 -2.18693627e-01 -3.33734144e-01 3.99005490e-01 -2.15088342 0.92741961 697.00 -2.38286455e-01 -3.03958355e-01 3.86226768e-01 -2.23567032 0.90665392 697.25 -2.31050441e-01 -2.58093251e-01 3.46405013e-01 -2.30096469 0.86193167 697.50 -1.86554861e-01 -2.09055170e-01 2.80190614e-01 -2.29938073 0.76251686 697.75 -1.29026422e-01 -2.42195284e-01 2.74420067e-01 -2.06028937 0.80030515 698.00 -1.27498982e-01 -2.95090022e-01 3.21456235e-01 -1.97863844 0.83674125 698.25 -1.41107380e-01 -3.12626004e-01 3.42996080e-01 -1.99478200 0.85747831 698.50 -1.41691160e-01 -3.19214777e-01 3.49248420e-01 -1.98854426 0.86766925 698.75 -1.58495969e-01 -3.15883745e-01 3.53416910e-01 -2.03584624 0.90311757 699.00 -1.65396998e-01 -3.04192494e-01 3.46250257e-01 -2.06880895 0.89258359 699.25 -1.42617129e-01 -2.92271410e-01 3.25211043e-01 -2.02476665 0.89766812 699.50 -1.31788005e-01 -3.24444461e-01 3.50188930e-01 -1.95663254 0.89125145 699.75 -1.22120971e-01 -3.60889275e-01 3.80991602e-01 -1.89709008 0.91875025 700.00 -1.72045688e-01 -3.85468963e-01 4.22120883e-01 -1.99059263 0.93072655 700.25 -2.12309632e-01 -3.80595296e-01 4.35807479e-01 -2.07963550 0.95143866 700.50 -2.29623250e-01 -3.44066790e-01 4.13652986e-01 -2.15929253 0.95245201 700.75 -2.50925074e-01 -3.21202581e-01 4.07595990e-01 -2.23397140 0.96008198 701.00 -2.55530894e-01 -2.80589484e-01 3.79508229e-01 -2.30948788 0.95630482 701.25 -2.44136146e-01 -2.55727346e-01 3.53551882e-01 -2.33300992 0.95326024 701.50 -2.29467600e-01 -2.14950327e-01 3.14418546e-01 -2.38884869 0.94163361 701.75 -2.15373695e-01 -2.10531765e-01 3.01180100e-01 -2.36756256 0.94979054 702.00 -1.88642439e-01 -1.89502633e-01 2.67389636e-01 -2.35391972 0.95191152 702.25 -1.81585942e-01 -1.71314703e-01 2.49644110e-01 -2.38529146 0.93717863 702.50 -1.45883657e-01 -1.57943151e-01 2.15007164e-01 -2.31652331 0.90606465 702.75 -1.23545344e-01 -1.62813609e-01 2.04381318e-01 -2.21991495 0.89697408 703.00 -9.36757202e-02 -1.67552421e-01 1.91960815e-01 -2.08058634 0.90992208 703.25 -8.30251026e-02 -1.69474400e-01 1.88718679e-01 -2.02632941 0.88592536 703.50 -5.80541829e-02 -1.78717341e-01 1.87910022e-01 -1.88488169 0.81929495 703.75 -6.30586380e-02 -1.72950509e-01 1.84087670e-01 -1.92042267 0.77752260 704.00 -2.72925217e-02 -1.54374620e-01 1.56768635e-01 -1.74578225 0.75830967 704.25 -1.87938716e-02 -1.65683177e-01 1.66745689e-01 -1.68374613 0.72787802 704.50 -3.11504203e-02 -1.79487105e-01 1.82170167e-01 -1.74263708 0.72433402 704.75 -2.86171718e-02 -1.82708680e-01 1.84936217e-01 -1.72616138 0.73934004 705.00 -4.22913081e-02 -1.90739111e-01 1.95371347e-01 -1.78898979 0.79104535 705.25 -5.17448058e-02 -1.77538309e-01 1.84925325e-01 -1.85439732 0.70435709 705.50 -4.11775041e-02 -1.39675844e-01 1.45619121e-01 -1.85748269 0.53157808 705.75 -3.52262307e-02 -1.12813348e-01 1.18185189e-01 -1.87345554 0.42094780 706.00 3.49833602e-02 -2.41264443e-02 4.24961269e-02 -0.60374912 0.06227651 706.25 1.04177920e-01 1.89621700e-02 1.05889579e-01 0.18004611 0.25936548 706.50 2.39988729e-01 4.52948294e-02 2.44225739e-01 0.18654298 0.71548781 706.75 3.31683208e-01 3.71423716e-03 3.31704003e-01 0.01119768 0.77452139 707.00 4.36444341e-01 -6.91509921e-02 4.41888586e-01 -0.15713551 0.86749971 707.25 5.06816694e-01 -1.63071255e-01 5.32405292e-01 -0.31129492 0.83756021 707.50 5.64699504e-01 -3.23373930e-01 6.50735145e-01 -0.52006474 0.88541181 707.75 5.38342016e-01 -4.39704425e-01 6.95091439e-01 -0.68488637 0.86530662 708.00 5.41371635e-01 -5.72501547e-01 7.87934812e-01 -0.81333834 0.92100673 708.25 4.74331674e-01 -6.80919894e-01 8.29844828e-01 -0.96235304 0.88595811 708.50 3.77561776e-01 -7.80582606e-01 8.67099821e-01 -1.12027980 0.85843423 708.75 2.70705568e-01 -7.51755222e-01 7.99010274e-01 -1.22515397 0.83544515 709.00 1.63779657e-01 -8.08824312e-01 8.25239689e-01 -1.37100671 0.81573158 709.25 9.29377369e-02 -8.05608523e-01 8.10951611e-01 -1.45594066 0.86598008 709.50 9.14828255e-02 -8.37156209e-01 8.42139909e-01 -1.46195014 0.90502108 709.75 7.19935098e-02 -7.94817904e-01 7.98071780e-01 -1.48046421 0.88069258 710.00 6.03769971e-02 -8.25290218e-01 8.27495816e-01 -1.49776792 0.89329872 710.25 4.76740897e-02 -8.48389984e-01 8.49728417e-01 -1.51466176 0.90147551 710.50 1.12047096e-02 -8.95358257e-01 8.95428364e-01 -1.55828276 0.91731435 710.75 -7.95483608e-02 -9.66169617e-01 9.69438843e-01 -1.65294478 0.92107382 711.00 -1.50748702e-01 -1.00147833e+00 1.01276059e+00 -1.72020083 0.92507278 711.25 -2.93735917e-01 -1.05759492e+00 1.09762826e+00 -1.84170767 0.91453441 711.50 -3.75177721e-01 -1.05168669e+00 1.11660343e+00 -1.91346210 0.93652933 711.75 -5.26306444e-01 -9.47503259e-01 1.08386387e+00 -2.07782688 0.93476757 712.00 -5.95506285e-01 -8.78010122e-01 1.06090976e+00 -2.16677216 0.94633730 712.25 -6.77845544e-01 -8.19231700e-01 1.06330389e+00 -2.26203232 0.97673350 712.50 -7.09571781e-01 -7.98315557e-01 1.06808232e+00 -2.29740924 0.97434060 712.75 -7.98106575e-01 -7.13288336e-01 1.07039916e+00 -2.41225486 0.94038552 713.00 -8.66731454e-01 -6.21876610e-01 1.06674924e+00 -2.51922047 0.95334394 713.25 -8.54786440e-01 -4.44812447e-01 9.63596374e-01 -2.66177551 0.96581313 713.50 -8.31473364e-01 -3.79437294e-01 9.13958760e-01 -2.71347618 0.95694159 713.75 -7.73454483e-01 -2.45064733e-01 8.11349839e-01 -2.83475479 0.94994726 714.00 -7.28747771e-01 -1.93424489e-01 7.53980336e-01 -2.88215420 0.94961558 714.25 -6.59783476e-01 -1.42955042e-01 6.75092867e-01 -2.92822118 0.95053851 714.50 -6.14973747e-01 -1.17276466e-01 6.26056290e-01 -2.95315366 0.95865413 714.75 -5.89088427e-01 -1.17510384e-01 6.00694485e-01 -2.94469874 0.97059661 715.00 -5.82150520e-01 -9.09225877e-02 5.89208065e-01 -2.98666035 0.95710107 715.25 -5.63410796e-01 -4.42282687e-02 5.65144110e-01 -3.06325239 0.95750597 715.50 -5.55933848e-01 -8.70241877e-03 5.56001956e-01 -3.12594024 0.94693227 715.75 -5.06137925e-01 8.74741438e-02 5.13641241e-01 2.97045649 0.93237687 716.00 -4.45619184e-01 1.35754107e-01 4.65838636e-01 2.84588304 0.90591754 716.25 -3.28744447e-01 1.57771519e-01 3.64643338e-01 2.69413650 0.88813373 716.50 -2.74602999e-01 1.35969538e-01 3.06422131e-01 2.68183297 0.80808187 716.75 -2.25677272e-01 1.37960353e-01 2.64505747e-01 2.59289336 0.75048900 717.00 -1.73810471e-01 1.37699876e-01 2.21746106e-01 2.47160041 0.66150107 717.25 -1.03121521e-01 1.01836657e-01 1.44930165e-01 2.36246331 0.46033708 717.50 -3.35941927e-02 4.31235936e-02 5.46645599e-02 2.23261376 0.11372294 717.75 2.59150147e-02 -2.29707721e-02 3.46301077e-02 -0.72524386 0.10218178 718.00 2.53629440e-02 -6.04609166e-02 6.55652451e-02 -1.17359921 0.28483278 718.25 1.02305065e-02 -1.14406249e-01 1.14862757e-01 -1.48161092 0.51336393 718.50 7.82819247e-03 -1.21027039e-01 1.21279943e-01 -1.50620495 0.49908559 718.75 2.60838165e-02 -1.16622331e-01 1.19503696e-01 -1.35075714 0.43219935 719.00 6.22748163e-02 -1.78792780e-01 1.89327787e-01 -1.23563035 0.60989744 719.25 6.28746663e-02 -2.25388931e-01 2.33994431e-01 -1.29875158 0.75110427 719.50 6.82722611e-02 -2.56595566e-01 2.65522854e-01 -1.31075151 0.78030039 719.75 8.05486633e-02 -2.78800402e-01 2.90202948e-01 -1.28954319 0.83073494 720.00 5.54455852e-02 -3.17722596e-01 3.22524202e-01 -1.39802670 0.88477908 720.25 5.65291367e-02 -3.51186662e-01 3.55707203e-01 -1.41119925 0.84680247 720.50 6.81784669e-02 -4.30471285e-01 4.35836931e-01 -1.41372006 0.82078227 720.75 9.54022349e-02 -4.59360735e-01 4.69162947e-01 -1.36602259 0.85959900 721.00 8.29977096e-02 -5.08025512e-01 5.14760664e-01 -1.40885389 0.91109771 721.25 5.58687840e-02 -5.43236082e-01 5.46101421e-01 -1.46831225 0.91776502 721.50 6.95443934e-02 -5.71019255e-01 5.75238570e-01 -1.44960326 0.91327335 721.75 8.67703602e-02 -5.65702314e-01 5.72318271e-01 -1.41859733 0.90566718 722.00 1.51181980e-01 -6.22778332e-01 6.40865697e-01 -1.33264889 0.86873558 722.25 2.39982218e-01 -7.18887413e-01 7.57885597e-01 -1.24860380 0.87778211 722.50 3.65877408e-01 -8.19915797e-01 8.97846419e-01 -1.15107546 0.82216797 722.75 5.35866565e-01 -9.31875266e-01 1.07496255e+00 -1.04893117 0.79271732 723.00 6.80345808e-01 -1.03196091e+00 1.23604762e+00 -0.98792865 0.59286803 723.25 8.49731680e-01 -6.99134919e-01 1.10037883e+00 -0.68847254 0.37923128 723.50 6.94980694e-01 3.68377869e-01 7.86575120e-01 0.48740138 0.18146332 723.75 4.34204047e-01 8.92400008e-01 9.92426787e-01 1.11796032 0.34017796 724.00 3.81189189e-01 8.56718687e-01 9.37695103e-01 1.15215750 0.58479980 724.25 2.57566083e-01 8.10658284e-01 8.50592229e-01 1.26315878 0.66816500 724.50 3.92370707e-02 6.17197524e-01 6.18443474e-01 1.50730881 0.67920077 724.75 -1.79978143e-02 5.28574973e-01 5.28881295e-01 1.60483287 0.72795974 725.00 -3.73459394e-02 4.28594440e-01 4.30218448e-01 1.65771264 0.77953464 725.25 -7.70842312e-02 3.77554909e-01 3.85343597e-01 1.77219533 0.79542211 725.50 -8.38813632e-02 3.05017790e-01 3.16341485e-01 1.83916702 0.75675921 725.75 -7.75910813e-02 2.44149379e-01 2.56182152e-01 1.87850387 0.70121723 726.00 -9.49254215e-02 2.25105733e-01 2.44301917e-01 1.96986224 0.79203590 726.25 -9.32215218e-02 2.17645871e-01 2.36769882e-01 1.97547352 0.72587691 726.50 -1.22083826e-01 1.76680133e-01 2.14756444e-01 2.17544823 0.64417829 726.75 -1.22950229e-01 1.53936906e-01 1.97010989e-01 2.24474734 0.55027007 727.00 -1.27729544e-01 1.16129542e-01 1.72629392e-01 2.40372712 0.54410538 727.25 -1.32930008e-01 8.71744637e-02 1.58964694e-01 2.56115635 0.52418569 727.50 -1.49625658e-01 9.39149951e-02 1.76657476e-01 2.58107824 0.61713793 727.75 -1.74745958e-01 6.78810206e-02 1.87467285e-01 2.77107792 0.57611511 728.00 -1.74927916e-01 4.67006249e-02 1.81054478e-01 2.88070645 0.55370673 728.25 -1.78701249e-01 4.33623736e-02 1.83887008e-01 2.90354079 0.52125311 728.50 -1.68470818e-01 2.41020390e-02 1.70186147e-01 2.99949329 0.50295493 728.75 -1.97389576e-01 3.89942618e-02 2.01204367e-01 2.94655421 0.45940268 729.00 -2.11117333e-01 6.89012123e-02 2.22076351e-01 2.82612707 0.49390366 729.25 -1.87854432e-01 7.47860557e-02 2.02193575e-01 2.76271974 0.48030739 729.50 -2.00964421e-01 1.19195373e-01 2.33654093e-01 2.60624971 0.58788309 729.75 -1.30856163e-01 1.01781161e-01 1.65779190e-01 2.48052975 0.41806338 730.00 -8.32907459e-02 7.54737475e-02 1.12399444e-01 2.40539120 0.29575778 730.25 -4.00152437e-02 5.36713582e-02 6.69465041e-02 2.21145008 0.12388895 730.50 -1.82740097e-02 4.09060076e-02 4.48022420e-02 1.99092900 0.07284889 730.75 -2.01232827e-02 -6.20187885e-03 2.10572982e-02 -2.84263531 0.02850470 731.00 -2.61417151e-02 -1.76677688e-02 3.15521683e-02 -2.54726215 0.08420089 731.25 -3.72937494e-02 -3.80670136e-02 5.32909116e-02 -2.34593402 0.16917476 731.50 -4.49037550e-02 -5.26913960e-02 6.92295488e-02 -2.27656784 0.24127202 731.75 -9.15163586e-02 -5.72323208e-02 1.07938790e-01 -2.58272154 0.49022086 732.00 -9.45416575e-02 -5.24810559e-02 1.08131338e-01 -2.63483439 0.53394905 732.25 -8.90347244e-02 -4.16695519e-02 9.83032741e-02 -2.70385918 0.48333154 732.50 -8.64799851e-02 -3.28121821e-02 9.24955518e-02 -2.77895310 0.44871681 732.75 -8.43441372e-02 -3.84080806e-02 9.26774737e-02 -2.71427916 0.44261597 733.00 -7.64672633e-02 -4.23746794e-02 8.74234283e-02 -2.63556539 0.48336118 733.25 -8.41522840e-02 -5.27196711e-02 9.93024201e-02 -2.58193022 0.64736580 733.50 -8.46606045e-02 -6.71459721e-02 1.08055539e-01 -2.47106127 0.70329216 733.75 -9.43659864e-02 -1.04432233e-01 1.40751663e-01 -2.30560220 0.76764381 734.00 -1.04021923e-01 -1.17277695e-01 1.56762936e-01 -2.29636632 0.77743769 734.25 -1.25059580e-01 -1.59941116e-01 2.03029700e-01 -2.23440912 0.79868026 734.50 -1.40800363e-01 -1.92385546e-01 2.38404993e-01 -2.20259004 0.83736130 734.75 -1.78070569e-01 -2.30348363e-01 2.91152016e-01 -2.22888634 0.82489720 735.00 -2.04636772e-01 -2.31457791e-01 3.08948082e-01 -2.29476910 0.77917123 735.25 -2.80278080e-01 -2.08866174e-01 3.49543818e-01 -2.50116386 0.72471360 735.50 -2.91238745e-01 -2.37890551e-01 3.76047764e-01 -2.45667754 0.73687041 735.75 -2.87798914e-01 -2.73888625e-01 3.97294845e-01 -2.38095460 0.63621872 736.00 -2.97076665e-01 -3.04440437e-01 4.25368693e-01 -2.34395310 0.65160133 736.25 -2.52849954e-01 -3.37575211e-01 4.21770224e-01 -2.21366874 0.58089665 736.50 -2.50221871e-01 -3.93190182e-01 4.66057404e-01 -2.13754353 0.49899983 736.75 -3.49335877e-01 -4.91530709e-01 6.03024040e-01 -2.18867422 0.46931433 737.00 -4.00360247e-01 -4.57477626e-01 6.07926069e-01 -2.28970967 0.41269658 737.25 -2.78235702e-01 -2.96257133e-01 4.06427601e-01 -2.32483549 0.19523872 737.50 -2.58653570e-01 -2.62136327e-01 3.68262302e-01 -2.34950714 0.12036162 737.75 -1.47893781e-01 -5.10878386e-01 5.31854582e-01 -1.85258252 0.12633167 738.00 -9.48192901e-02 -4.48303225e-01 4.58220994e-01 -1.77923147 0.10264190 738.25 -5.99005027e-02 -2.39261960e-01 2.46646215e-01 -1.81610937 0.03378714 738.50 1.37917953e-01 -2.30636807e-01 2.68727926e-01 -1.03185784 0.03448957 738.75 5.67560023e-01 -1.06730774e-01 5.77508301e-01 -0.18588111 0.12785122 739.00 8.16428273e-01 -5.52883508e-01 9.86019928e-01 -0.59525806 0.28895913 739.25 1.09754137e+00 -9.64789923e-01 1.46130649e+00 -0.72111724 0.60740933 739.50 7.95347964e-01 -9.25879719e-01 1.22058660e+00 -0.86108971 0.51117817 739.75 6.71801114e-01 -9.03660865e-01 1.12601940e+00 -0.93151863 0.55426899 740.00 6.82688132e-01 -9.72639997e-01 1.18831463e+00 -0.95880176 0.64194065 740.25 7.20584312e-01 -8.87936701e-01 1.14353545e+00 -0.88906634 0.71347842 740.50 7.70412031e-01 -8.30844795e-01 1.13306565e+00 -0.82312109 0.64349869 740.75 6.52448195e-01 -5.88650974e-01 8.78748323e-01 -0.73403956 0.47042757 741.00 6.80005152e-01 -3.32204025e-01 7.56813399e-01 -0.45443089 0.36482324 741.25 5.86281178e-01 -4.66702829e-01 7.49357825e-01 -0.67232118 0.38042440 741.50 7.90506417e-01 -4.21248783e-01 8.95740438e-01 -0.48960799 0.52492936 741.75 8.97180964e-01 -6.01169042e-01 1.07997125e+00 -0.59035121 0.65103328 742.00 7.53583359e-01 -8.27270051e-01 1.11904585e+00 -0.83197642 0.62178982 742.25 2.88446226e-01 -7.83279703e-01 8.34702533e-01 -1.21795265 0.51006436 742.50 3.24269747e-02 -4.98288197e-01 4.99342204e-01 -1.50581121 0.34906645 742.75 -4.79402160e-02 -4.20246564e-01 4.22972149e-01 -1.68438172 0.29346061 743.00 -3.47387904e-01 -3.72541130e-02 3.49379771e-01 -3.03476028 0.22320016 743.25 -3.96545384e-01 1.37583793e-01 4.19735085e-01 2.80763222 0.33565522 743.50 -4.62631445e-01 2.18991662e-01 5.11844901e-01 2.69948248 0.39762620 743.75 -5.56145070e-01 3.08301627e-01 6.35883033e-01 2.63541226 0.44273115 744.00 -7.42828201e-01 7.77402473e-01 1.07524339e+00 2.33345563 0.62524069 744.25 -8.15377118e-01 9.31331212e-01 1.23782780e+00 2.28990740 0.70085670 744.50 -8.92279888e-01 1.13376666e+00 1.44277172e+00 2.23756303 0.80227497 744.75 -8.79145920e-01 1.40630187e+00 1.65848802e+00 2.12950161 0.80884050 745.00 -4.94428482e-01 1.81255937e+00 1.87878444e+00 1.83709670 0.85425881 745.25 -2.10274730e-01 2.02139976e+00 2.03230717e+00 1.67444784 0.86670930 745.50 3.51990109e-01 2.18749643e+00 2.21563483e+00 1.41125388 0.93641549 745.75 5.25465500e-01 2.13608646e+00 2.19976802e+00 1.32959109 0.95617092 746.00 7.89460258e-01 2.13155638e+00 2.27305523e+00 1.21609277 0.95476373 746.25 1.03302327e+00 2.16600353e+00 2.39973090e+00 1.12577777 0.94868280 746.50 1.42153209e+00 2.18292095e+00 2.60497551e+00 0.99357349 0.95058194 746.75 1.68716395e+00 2.10512582e+00 2.69779112e+00 0.89516872 0.93364969 747.00 2.09210501e+00 1.83677213e+00 2.78399627e+00 0.72050066 0.90348412 747.25 2.07978338e+00 1.20907362e+00 2.40569282e+00 0.52659034 0.78241529 747.50 1.73775178e+00 2.69677229e-01 1.75855254e+00 0.15395933 0.79273651 747.75 1.50231689e+00 2.47593626e-01 1.52258288e+00 0.16333956 0.84241399 748.00 1.26863586e+00 2.24304667e-01 1.28831267e+00 0.17499917 0.86408551 748.25 1.16654246e+00 3.25729507e-01 1.21116515e+00 0.27229124 0.83146318 748.50 1.08277597e+00 4.26184127e-01 1.16363083e+00 0.37497979 0.76491223 748.75 1.06923129e+00 2.39154634e-01 1.09565072e+00 0.22004788 0.69722106 749.00 1.19548137e+00 1.28188775e-01 1.20233442e+00 0.10681960 0.76890184 749.25 1.02515123e+00 1.76134367e-01 1.04017228e+00 0.17015176 0.72145406 749.50 7.93023825e-01 2.53959886e-01 8.32695869e-01 0.30992285 0.63081729 749.75 6.69784384e-01 2.65467962e-01 7.20475093e-01 0.37735448 0.53309103 750.00 5.16566821e-01 3.13441294e-01 6.04224069e-01 0.54538830 0.49487408 750.25 1.50511809e-01 4.40076713e-01 4.65103556e-01 1.24125482 0.31982430 750.50 -9.97231441e-02 7.06273981e-01 7.13279498e-01 1.71106520 0.56910508 750.75 -2.11043452e-01 1.05683081e+00 1.07769694e+00 1.76789826 0.70798184 751.00 -3.29808290e-01 1.43058194e+00 1.46810701e+00 1.79737880 0.76548613 751.25 -2.17142870e-01 1.62237614e+00 1.63684311e+00 1.70384809 0.64039428 751.50 9.32399413e-02 2.00508679e+00 2.00725353e+00 1.52432810 0.63829436 751.75 1.36357887e-01 1.98467901e+00 1.98935775e+00 1.50219887 0.56361911 752.00 -1.05052282e-01 1.56220993e+00 1.56573811e+00 1.63794118 0.32334440 752.25 -5.74103529e-01 1.03496489e+00 1.18353166e+00 2.07724710 0.21766745 752.50 -4.34981103e-01 8.88622810e-01 9.89373063e-01 2.02600892 0.20785622 752.75 -4.35266476e-01 1.05183476e+00 1.13833794e+00 1.96315636 0.24561205 753.00 -1.96110915e-01 1.03670007e+00 1.05508603e+00 1.75775554 0.21875663 753.25 3.95896160e-01 1.28897395e+00 1.34840188e+00 1.27280152 0.24867885 753.50 7.67827317e-01 1.59902336e+00 1.77381918e+00 1.12312586 0.38315923 753.75 1.63880158e+00 1.06543815e+00 1.95469411e+00 0.57646835 0.38789227 754.00 2.01998655e+00 6.78302466e-01 2.13083080e+00 0.32396490 0.46005928 754.25 2.53232664e+00 2.48415741e-01 2.54448198e+00 0.09778496 0.40412776 754.50 2.87805564e+00 -4.20571926e-01 2.90862252e+00 -0.14510354 0.41477472 754.75 3.18760700e+00 -1.59268314e+00 3.56335207e+00 -0.46336639 0.58292392 755.00 3.20528992e+00 -1.66919029e+00 3.61387322e+00 -0.48011820 0.60606467 755.25 2.09829062e+00 -8.55248450e-01 2.26589352e+00 -0.38703483 0.36656787 755.50 2.03482973e+00 -1.09250801e+00 2.30956831e+00 -0.49273305 0.39513333 755.75 1.92153974e+00 -1.45678808e+00 2.41133707e+00 -0.64868772 0.49236953 756.00 1.69032693e+00 -1.35229654e+00 2.16469653e+00 -0.67475357 0.48691872 756.25 9.88693954e-01 -1.33605076e+00 1.66209126e+00 -0.93371807 0.31309750 756.50 2.90658180e-01 -1.00756264e+00 1.04864897e+00 -1.28994476 0.11881758 756.75 -7.02623087e-01 -4.34584479e-01 8.26161528e-01 -2.58766870 0.08634377 757.00 -7.96278002e-01 -1.50982502e-01 8.10465528e-01 -2.95420687 0.09688828 757.25 -8.00440639e-01 -4.48115117e-01 9.17339835e-01 -2.63122954 0.11715550 757.50 -1.33973825e+00 -1.37766971e-01 1.34680300e+00 -3.03912157 0.23924812 757.75 -1.95313530e+00 6.98095653e-02 1.95438248e+00 3.10586555 0.41780146 758.00 -1.81102732e+00 1.96301712e-01 1.82163507e+00 3.03362172 0.47037606 758.25 -2.00444185e+00 3.48663530e-01 2.03454009e+00 2.96937039 0.59945251 758.50 -1.99491571e+00 3.85930997e-01 2.03190340e+00 2.95049600 0.57062540 758.75 -1.67357934e+00 3.62196944e-01 1.71232428e+00 2.92845911 0.42259456 759.00 -1.79286555e+00 5.63461290e-01 1.87932316e+00 2.83708722 0.55461046 759.25 -2.01579716e+00 3.60631172e-01 2.04780200e+00 2.96456297 0.66795529 759.50 -1.94246940e+00 3.38556153e-01 1.97175243e+00 2.96903439 0.71675645 759.75 -1.85566719e+00 5.41503344e-01 1.93306146e+00 2.85766591 0.75567675 760.00 -1.84606214e+00 8.73081857e-01 2.04211101e+00 2.69982412 0.76605605 760.25 -1.87602727e+00 1.16700743e+00 2.20938558e+00 2.58510802 0.79731001 760.50 -1.47017322e+00 1.16731409e+00 1.87724039e+00 2.47052241 0.73332310 760.75 -1.13591073e+00 1.23948428e+00 1.68125384e+00 2.31261943 0.81288050 761.00 -1.01947854e+00 1.09086296e+00 1.49309025e+00 2.32238138 0.80553966 761.25 -1.06265822e+00 9.01584998e-01 1.39359176e+00 2.43801411 0.81135335 761.50 -1.00977099e+00 7.46358494e-01 1.25566256e+00 2.50508058 0.69430951 761.75 -9.28708149e-01 6.32069200e-01 1.12339232e+00 2.54401287 0.60637793 762.00 -7.91087228e-01 6.15423424e-01 1.00227990e+00 2.48044446 0.51153571 762.25 -1.06619031e+00 6.73474227e-01 1.26108259e+00 2.57821546 0.58320005 762.50 -1.31453972e+00 6.00766176e-01 1.44531473e+00 2.71291925 0.40242381 762.75 -1.41225814e+00 6.09761126e-01 1.53827231e+00 2.73400747 0.32924580 763.00 -1.36905373e+00 1.33570392e+00 1.91269786e+00 2.36852392 0.56837837 763.25 -1.27695026e+00 1.33457361e+00 1.84707571e+00 2.33413304 0.57045199 763.50 -1.56390967e+00 1.56052438e+00 2.20930980e+00 2.35727798 0.69696365 763.75 -1.79626336e+00 1.83867737e+00 2.57046621e+00 2.34452660 0.77747765 764.00 -1.24465343e+00 1.98602377e+00 2.34381155e+00 2.13062164 0.78026373 764.25 -1.18938772e+00 2.02189405e+00 2.34578318e+00 2.10253446 0.81804759 764.50 -1.17937896e+00 2.37129726e+00 2.64839299e+00 2.03232651 0.93000090 764.75 -1.11730280e+00 2.37792782e+00 2.62733825e+00 2.01004586 0.96492704 765.00 -1.17685684e+00 2.21035841e+00 2.50413185e+00 2.06004859 0.96336576 765.25 -1.23589112e+00 2.13211167e+00 2.46441211e+00 2.09612261 0.96509731 765.50 -1.36577307e+00 1.98741023e+00 2.41145921e+00 2.17288839 0.95991297 765.75 -1.43150340e+00 1.96686045e+00 2.43264095e+00 2.19994482 0.94515347 766.00 -1.63889877e+00 2.24002640e+00 2.77555534e+00 2.20244482 0.95251035 766.25 -1.80027331e+00 2.52835194e+00 3.10379567e+00 2.18955343 0.94883995 766.50 -1.81736740e+00 3.11147863e+00 3.60334894e+00 2.09943128 0.95116619 766.75 -1.72380861e+00 3.42797576e+00 3.83699543e+00 2.03673321 0.94526764 767.00 -1.20818368e+00 4.03221953e+00 4.20933512e+00 1.86191585 0.94504093 767.25 -7.12762022e-01 4.18395323e+00 4.24423071e+00 1.73953258 0.91975767 767.50 3.28917423e-01 4.07307833e+00 4.08633745e+00 1.49021717 0.91698204 767.75 7.43025921e-01 3.74568032e+00 3.81866582e+00 1.37496977 0.90756089 768.00 1.24867838e+00 3.02521842e+00 3.27278844e+00 1.17934162 0.90384523 768.25 1.32085957e+00 2.61379333e+00 2.92858081e+00 1.10288425 0.92539161 768.50 1.28289509e+00 2.24205464e+00 2.58314321e+00 1.05107175 0.94038738 768.75 1.03497774e+00 1.92597737e+00 2.18645095e+00 1.07769538 0.92627624 769.00 7.19030681e-01 1.68956726e+00 1.83620332e+00 1.16844221 0.92220187 769.25 6.49422171e-01 1.78591936e+00 1.90033079e+00 1.22202683 0.92545807 769.50 5.93113962e-01 2.05695718e+00 2.14076085e+00 1.29006590 0.93501107 769.75 4.94274254e-01 2.13150623e+00 2.18806441e+00 1.34293396 0.92559663 770.00 4.04889819e-01 2.25546451e+00 2.29151826e+00 1.39317316 0.91935507 770.25 5.50589390e-01 2.29990570e+00 2.36489216e+00 1.33582205 0.91210081 770.50 6.52911011e-01 2.23871384e+00 2.33198037e+00 1.28702164 0.90491637 770.75 7.90147590e-01 2.14632459e+00 2.28714724e+00 1.21805357 0.89851120 771.00 8.57945922e-01 1.96019656e+00 2.13972937e+00 1.15823178 0.87355558 771.25 8.86846586e-01 1.86315981e+00 2.06345859e+00 1.12654005 0.87822886 771.50 9.02485242e-01 1.91411744e+00 2.11620537e+00 1.13021658 0.87498228 771.75 7.60991195e-01 1.87411371e+00 2.02272336e+00 1.18508198 0.71923555 772.00 7.36173797e-01 2.10311815e+00 2.22824097e+00 1.23408658 0.69006134 772.25 8.17757994e-01 2.46442565e+00 2.59655963e+00 1.25040390 0.65576972 772.50 1.29013675e+00 2.60187409e+00 2.90416969e+00 1.11047500 0.60721523 772.75 2.67214558e+00 2.08676301e+00 3.39041913e+00 0.66300526 0.58826844 773.00 3.61604745e+00 1.25708806e+00 3.82832464e+00 0.33457214 0.61658963 773.25 3.76190332e+00 -2.71949140e-01 3.77172015e+00 -0.07216477 0.75769534 773.50 3.52722390e+00 -7.08322462e-01 3.59764216e+00 -0.19817991 0.81393013 773.75 2.82675335e+00 -1.48964370e+00 3.19524223e+00 -0.48499825 0.83355356 774.00 2.45897857e+00 -1.70139704e+00 2.99020526e+00 -0.60527720 0.85259057 774.25 2.13573739e+00 -1.88959885e+00 2.85165882e+00 -0.72432688 0.88428506 774.50 1.96082522e+00 -1.97063588e+00 2.77997146e+00 -0.78789358 0.89414175 774.75 1.44439096e+00 -2.07291821e+00 2.52651047e+00 -0.96222724 0.80467788 775.00 8.21772277e-01 -2.16844783e+00 2.31893848e+00 -1.20855143 0.79966722 775.25 3.84824754e-01 -2.18041171e+00 2.21411050e+00 -1.39610357 0.87448411 775.50 2.71951798e-01 -1.97943265e+00 1.99802688e+00 -1.43426234 0.87901570 775.75 1.76972985e-02 -1.91395217e+00 1.91403399e+00 -1.56155012 0.92585264 776.00 -1.86059826e-02 -1.94214695e+00 1.94223607e+00 -1.58037614 0.91581092 776.25 -1.73979767e-01 -2.07807361e+00 2.08534383e+00 -1.65432319 0.87665791 776.50 -2.22239627e-01 -2.19747003e+00 2.20867946e+00 -1.67158794 0.88654269 776.75 -3.86417038e-01 -2.25180387e+00 2.28471854e+00 -1.74074436 0.90533683 777.00 -6.75641115e-01 -2.19874531e+00 2.30021126e+00 -1.86892299 0.89416906 777.25 -1.31487957e+00 -2.17768055e+00 2.54385551e+00 -2.11400393 0.87457098 777.50 -1.60806101e+00 -2.03068336e+00 2.59027703e+00 -2.24056745 0.85041771 777.75 -2.11933169e+00 -1.71470043e+00 2.72612626e+00 -2.46134201 0.84038024 778.00 -2.33347539e+00 -1.51271444e+00 2.78090136e+00 -2.56643687 0.78156453 778.25 -2.55164053e+00 -7.33238824e-01 2.65490274e+00 -2.86177236 0.81012421 778.50 -2.55730886e+00 -4.37836688e-01 2.59451914e+00 -2.97202678 0.77541077 778.75 -2.53103916e+00 1.29515517e-01 2.53435071e+00 3.09046636 0.70905258 779.00 -1.97998862e+00 2.86073551e-01 2.00054818e+00 2.99810319 0.60545439 779.25 -1.59386372e+00 8.18771222e-01 1.79186715e+00 2.66704351 0.68662694 779.50 -1.50029587e+00 9.38649501e-01 1.76973178e+00 2.58253114 0.70628377 779.75 -1.22660675e+00 1.39260607e+00 1.85577902e+00 2.29290158 0.74762244 780.00 -8.52556313e-01 1.65752105e+00 1.86392819e+00 2.04586286 0.75251133 780.25 -5.47944464e-01 1.80550705e+00 1.88682242e+00 1.86544737 0.80046706 780.50 -7.32204153e-02 1.54865740e+00 1.55038736e+00 1.61804108 0.74323897 780.75 3.91692554e-01 1.31302535e+00 1.37020386e+00 1.28088794 0.74136221 781.00 5.38531263e-01 1.01421952e+00 1.14832798e+00 1.08267221 0.66023791 781.25 5.57284997e-01 6.79318984e-01 8.78658551e-01 0.88376445 0.52067265 781.50 5.03547948e-01 3.73855387e-01 6.27158981e-01 0.63864672 0.38823174 781.75 5.64707597e-01 1.65205021e-01 5.88376894e-01 0.28460769 0.46052875 782.00 3.42458181e-01 -9.82747283e-02 3.56280125e-01 -0.27945888 0.18398956 782.25 3.08402299e-01 -2.11086758e-01 3.73723959e-01 -0.60021509 0.21452629 782.50 8.89643548e-02 -2.66029857e-01 2.80511214e-01 -1.24807266 0.14262319 782.75 -7.46482622e-02 -3.24677518e-01 3.33148396e-01 -1.79678407 0.23453088 783.00 -2.73520246e-01 -2.83224673e-01 3.93737908e-01 -2.33876560 0.36027681 783.25 -3.60971736e-01 -2.35109244e-01 4.30786433e-01 -2.56428784 0.43771939 783.50 -4.26674102e-01 -1.22235691e-01 4.43838206e-01 -2.86258068 0.55491847 783.75 -4.56220665e-01 -7.63616595e-02 4.62567182e-01 -2.97575119 0.58466563 784.00 -4.20009158e-01 -5.27184994e-02 4.23304775e-01 -3.01672815 0.59562721 784.25 -4.44826316e-01 -6.00055889e-02 4.48855346e-01 -3.00750541 0.67917143 784.50 -5.35668570e-01 -1.34896496e-01 5.52392869e-01 -2.89489399 0.75549221 784.75 -6.22794975e-01 -1.94090701e-01 6.52337934e-01 -2.83948726 0.81707890 785.00 -7.44141928e-01 -2.59822039e-01 7.88197121e-01 -2.80566942 0.85294897 785.25 -8.29059320e-01 -2.65023745e-01 8.70388959e-01 -2.83219089 0.85361584 785.50 -9.96209149e-01 7.06840460e-03 9.96234225e-01 3.13449747 0.77684942 785.75 -1.16719202e+00 6.39536489e-02 1.16894280e+00 3.08685465 0.83362066 786.00 -1.44395751e+00 7.81435675e-02 1.44607044e+00 3.08752776 0.89265795 786.25 -1.57871637e+00 2.72850232e-01 1.60212129e+00 2.97045286 0.87122933 786.50 -1.74059850e+00 5.16320806e-01 1.81556336e+00 2.85322673 0.86265248 786.75 -1.74011330e+00 7.43684865e-01 1.89236928e+00 2.73771017 0.84239541 787.00 -1.57912206e+00 1.37016122e+00 2.09068607e+00 2.42692769 0.91930319 787.25 -1.42616310e+00 1.55498633e+00 2.10995822e+00 2.31300875 0.90556864 787.50 -1.02943974e+00 1.95826121e+00 2.21235918e+00 2.05478465 0.86563991 787.75 -7.79120263e-01 2.22509865e+00 2.35756069e+00 1.90760556 0.87203529 788.00 -4.46429514e-01 2.48047918e+00 2.52033257e+00 1.74886711 0.86308145 788.25 1.70494047e-01 2.38678635e+00 2.39286800e+00 1.49948498 0.80846894 788.50 1.14681437e+00 2.28237287e+00 2.55429229e+00 1.10517800 0.87559269 788.75 1.36045157e+00 1.90529009e+00 2.34114476e+00 0.95071018 0.87120983 789.00 1.56085582e+00 1.23246082e+00 1.98877615e+00 0.66837081 0.89429745 789.25 1.56514203e+00 9.54427941e-01 1.83319455e+00 0.54759626 0.84482493 789.50 1.47897612e+00 3.95029731e-01 1.53082293e+00 0.26100389 0.86042062 789.75 1.28079251e+00 1.54575800e-01 1.29008648e+00 0.12010673 0.84142595 790.00 1.00834159e+00 -1.06981939e-01 1.01400093e+00 -0.10570149 0.83403507 790.25 7.87554974e-01 -1.35937941e-01 7.99200826e-01 -0.17092338 0.74659516 790.50 6.17773729e-01 -7.74127489e-02 6.22605103e-01 -0.12465945 0.63772522 790.75 5.49719152e-01 -5.63814989e-02 5.52602949e-01 -0.10220680 0.57996420 791.00 4.69290127e-01 -6.32274262e-02 4.73530284e-01 -0.13392348 0.53626674 791.25 3.65137564e-01 -2.05677715e-01 4.19080855e-01 -0.51298808 0.48234167 791.50 1.55921625e-01 -2.58172398e-01 3.01603283e-01 -1.02748200 0.32205142 791.75 8.75544920e-02 -1.32060838e-01 1.58448269e-01 -0.98534618 0.15921014 792.00 3.67332658e-02 -5.67152975e-02 6.75718712e-02 -0.99605498 0.04226187 792.25 4.50430541e-02 6.48865913e-03 4.55080149e-02 0.14307037 0.01961103 792.50 7.20708071e-02 1.48304763e-01 1.64889368e-01 1.11844026 0.24732800 792.75 4.30159262e-02 2.25137377e-01 2.29209966e-01 1.38200646 0.44450664 793.00 4.98045322e-02 2.55568408e-01 2.60376079e-01 1.37833107 0.54072318 793.25 1.46429746e-01 2.74116179e-01 3.10775401e-01 1.08017335 0.54634526 793.50 2.33478620e-01 2.96115782e-01 3.77089940e-01 0.90312508 0.58416679 793.75 3.52657319e-01 1.54075941e-01 3.84846177e-01 0.41190663 0.58939879 794.00 3.34759867e-01 8.31713151e-02 3.44937148e-01 0.24351994 0.58934412 794.25 1.73631880e-01 3.28181088e-02 1.76706134e-01 0.18680597 0.26851089 794.50 8.52648430e-02 4.19407514e-02 9.50216821e-02 0.45713696 0.14360322 794.75 -4.39209539e-02 1.32707996e-01 1.39787204e-01 1.89040879 0.22186112 795.00 -1.16683806e-01 2.42793310e-01 2.69376506e-01 2.01879494 0.57110524 795.25 -9.47219094e-02 4.29929035e-01 4.40239952e-01 1.78765171 0.75188413 795.50 -4.34904066e-02 5.75309258e-01 5.76950741e-01 1.64624765 0.84228029 795.75 1.43517462e-01 6.72176489e-01 6.87327064e-01 1.36044326 0.85928800 796.00 2.55970898e-01 6.91103813e-01 7.36984112e-01 1.21608237 0.89868659 796.25 3.96506500e-01 6.60707694e-01 7.70553088e-01 1.03028570 0.90020271 796.50 4.64651054e-01 6.29944549e-01 7.82771190e-01 0.93527450 0.86424551 796.75 5.88966871e-01 6.07179831e-01 8.45901485e-01 0.80062335 0.84872443 797.00 6.51467730e-01 5.42870701e-01 8.48008727e-01 0.69472100 0.86209654 797.25 6.78428231e-01 4.66780948e-01 8.23498220e-01 0.60264912 0.89625366 797.50 7.01367734e-01 4.25563330e-01 8.20378478e-01 0.54537677 0.87595147 797.75 6.92849964e-01 3.94062820e-01 7.97073759e-01 0.51712936 0.87493597 798.00 7.05080763e-01 4.22368468e-01 8.21908757e-01 0.53971007 0.84745891 798.25 7.10674879e-01 5.29975026e-01 8.86528235e-01 0.64076582 0.79760856 798.50 7.47562948e-01 5.37925205e-01 9.20985281e-01 0.62374098 0.79435956 798.75 9.61529799e-01 6.56700326e-01 1.16438605e+00 0.59920783 0.88649087 799.00 1.16664547e+00 6.96712978e-01 1.35884901e+00 0.53835327 0.86435420 799.25 1.47786003e+00 6.77538362e-01 1.62577013e+00 0.42986620 0.86438611 799.50 1.58970707e+00 6.84470018e-01 1.73079975e+00 0.40657362 0.79958372 799.75 2.09275983e+00 8.67460561e-01 2.26542082e+00 0.39294828 0.80118090 800.00 2.31206783e+00 7.04956283e-01 2.41715142e+00 0.29594881 0.75914093 800.25 2.44773337e+00 5.77440735e-01 2.51492275e+00 0.23167260 0.64094596 800.50 2.41082524e+00 2.11795524e-01 2.42011067e+00 0.08762691 0.41001278 800.75 1.75565553e+00 -8.91407677e-01 1.96899314e+00 -0.46981641 0.16896264 801.00 -2.89320000e-01 -1.57013386e+00 1.59656707e+00 -1.75301688 0.13384867 801.25 -1.73650749e+00 -2.24023993e+00 2.83445465e+00 -2.23019606 0.48278831 801.50 -1.86165898e+00 -1.41448277e+00 2.33806238e+00 -2.49185094 0.56314571 801.75 -1.94201527e+00 -9.27853245e-01 2.15228598e+00 -2.69587971 0.78814332 802.00 -1.74246909e+00 -6.23362925e-01 1.85061607e+00 -2.79803310 0.85399188 802.25 -1.41722354e+00 -5.88977254e-01 1.53473671e+00 -2.74772330 0.88504541 802.50 -1.11679917e+00 -5.32340304e-01 1.23718494e+00 -2.69678581 0.92658063 802.75 -1.02992862e+00 -4.80460351e-01 1.13648366e+00 -2.70510344 0.96370601 803.00 -9.25568996e-01 -4.11023540e-01 1.01272816e+00 -2.72367553 0.97158489 803.25 -8.78846913e-01 -3.75872107e-01 9.55851315e-01 -2.73744762 0.98386208 803.50 -7.99680846e-01 -3.42218611e-01 8.69829312e-01 -2.73723107 0.97212253 803.75 -7.43999756e-01 -3.09275944e-01 8.05721569e-01 -2.74763093 0.97398506 804.00 -7.17437753e-01 -2.70052741e-01 7.66580336e-01 -2.78158395 0.97148577 804.25 -6.89030640e-01 -2.51809289e-01 7.33601486e-01 -2.79121687 0.97609012 804.50 -6.41575406e-01 -2.18157990e-01 6.77651762e-01 -2.81382292 0.98150490 804.75 -6.24384870e-01 -1.93287224e-01 6.53617944e-01 -2.84138459 0.98665140 805.00 -5.75308665e-01 -1.51010981e-01 5.94797761e-01 -2.88489659 0.98051291 805.25 -5.38534587e-01 -1.33941137e-01 5.54941195e-01 -2.89782463 0.98581656 805.50 -5.14674318e-01 -1.33677608e-01 5.31751216e-01 -2.88747524 0.99148216 805.75 -5.07412313e-01 -1.23774336e-01 5.22290476e-01 -2.90233271 0.99284854 806.00 -4.94830040e-01 -1.01686695e-01 5.05170221e-01 -2.93891597 0.99027756 806.25 -4.85268625e-01 -8.99971694e-02 4.93543442e-01 -2.95821764 0.99204689 806.50 -4.68238846e-01 -5.51775826e-02 4.71478719e-01 -3.02429294 0.98725659 806.75 -4.50702947e-01 -3.57492756e-02 4.52118521e-01 -3.06243944 0.98918595 807.00 -4.18825983e-01 -7.66769289e-03 4.18896165e-01 -3.12328711 0.98876653 807.25 -3.93204967e-01 -3.77196856e-03 3.93223058e-01 -3.13200007 0.98732568 807.50 -3.59534151e-01 1.47955359e-03 3.59537195e-01 3.13747748 0.98507206 807.75 -3.43855006e-01 2.66492214e-03 3.43865333e-01 3.13384268 0.98404446 808.00 -3.19357469e-01 2.13211954e-03 3.19364587e-01 3.13491647 0.98095631 808.25 -3.00073996e-01 -1.43620694e-04 3.00074030e-01 -3.14111404 0.97551602 808.50 -2.71375113e-01 -1.15460775e-02 2.71620625e-01 -3.09907174 0.97560557 808.75 -2.62894266e-01 -2.43692686e-02 2.64021318e-01 -3.04916071 0.97037041 809.00 -2.55187762e-01 -5.21202389e-02 2.60455971e-01 -2.94012092 0.96919956 809.25 -2.64089998e-01 -6.87126217e-02 2.72882670e-01 -2.88705002 0.96945305 809.50 -2.92119005e-01 -7.52743160e-02 3.01661625e-01 -2.88939542 0.97004461 809.75 -3.13861410e-01 -6.41922052e-02 3.20358587e-01 -2.93985086 0.97554265 810.00 -3.27958489e-01 -3.98033119e-02 3.30365062e-01 -3.02081643 0.96667988 810.25 -3.32383891e-01 -9.84317797e-03 3.32529607e-01 -3.11198742 0.95508694 810.50 -3.09960352e-01 3.33925501e-02 3.11753881e-01 3.03427487 0.94236536 810.75 -2.77602461e-01 4.51164493e-02 2.81244769e-01 2.98047952 0.90796016 811.00 -2.50560031e-01 4.82577644e-02 2.55164929e-01 2.95132287 0.87872828 811.25 -2.17267389e-01 2.57461687e-02 2.18787530e-01 3.02364277 0.80983792 811.50 -1.89659953e-01 -1.65224679e-02 1.90378281e-01 -3.05469577 0.72262189 811.75 -2.04212230e-01 -6.59846353e-02 2.14608031e-01 -2.82906395 0.79126071 812.00 -2.21616886e-01 -1.00175376e-01 2.43205983e-01 -2.71705975 0.83361624 812.25 -2.76124062e-01 -1.31725654e-01 3.05934871e-01 -2.69647105 0.83020524 812.50 -3.56278171e-01 -1.36884324e-01 3.81669298e-01 -2.77477522 0.88408960 812.75 -4.07363644e-01 -1.14961869e-01 4.23274579e-01 -2.86653631 0.85107298 813.00 -4.82986317e-01 -1.11147377e-01 4.95610252e-01 -2.91540525 0.84756331 813.25 -5.85411961e-01 -1.23048027e-02 5.85541265e-01 -3.12057670 0.73655718 813.50 -6.57464272e-01 1.83240716e-01 6.82522109e-01 2.86978219 0.63316047 813.75 -3.33785031e-01 6.04950099e-01 6.90924793e-01 2.07498695 0.65793607 814.00 -5.61317461e-02 6.19409127e-01 6.21947296e-01 1.66117091 0.77957139 814.25 -1.48504471e-02 3.92382058e-01 3.92662979e-01 1.60862518 0.83470500 814.50 -4.12676509e-02 3.25435114e-01 3.28041206e-01 1.69693073 0.91024272 814.75 -1.09421575e-01 2.77612168e-01 2.98398386e-01 1.94625175 0.92074083 815.00 -1.67907942e-01 2.80550790e-01 3.26958442e-01 2.11010768 0.93448339 815.25 -2.14359181e-01 3.40079253e-01 4.01999698e-01 2.13321301 0.94696287 815.50 -2.14792066e-01 3.71081850e-01 4.28762604e-01 2.09550168 0.95434459 815.75 -1.82869780e-01 4.42906544e-01 4.79173834e-01 1.96236148 0.92206497 816.00 -1.83683660e-01 5.19382336e-01 5.50906251e-01 1.91072612 0.93934512 816.25 -9.13499467e-02 5.55722677e-01 5.63180705e-01 1.73371976 0.90763315 816.50 4.22607438e-02 6.09353146e-01 6.10816852e-01 1.50155375 0.89872225 816.75 1.80601169e-01 6.46831769e-01 6.71571381e-01 1.29852139 0.90737526 817.00 2.79762385e-01 5.99080157e-01 6.61183807e-01 1.13390651 0.87961587 817.25 4.96905489e-01 4.82596240e-01 6.92686218e-01 0.77079050 0.90302829 817.50 5.94166433e-01 4.07053316e-01 7.20226459e-01 0.60064423 0.89973681 817.75 6.70446639e-01 1.85737932e-01 6.95699127e-01 0.27025818 0.87194765 818.00 6.47331947e-01 9.27656342e-02 6.53945038e-01 0.14233552 0.85662020 818.25 5.73867583e-01 -1.11753734e-01 5.84647672e-01 -0.19233071 0.86415213 818.50 4.96897023e-01 -2.03547419e-01 5.36971325e-01 -0.38878645 0.85833261 818.75 3.83981088e-01 -2.69106407e-01 4.68892029e-01 -0.61128444 0.80209305 819.00 3.36688585e-01 -3.06347822e-01 4.55201264e-01 -0.73824955 0.79854994 819.25 2.90414144e-01 -3.72140041e-01 4.72047227e-01 -0.90812797 0.82621946 819.50 2.60394568e-01 -3.96584572e-01 4.74430874e-01 -0.98980041 0.79573355 819.75 1.78905336e-01 -4.74017811e-01 5.06655706e-01 -1.20990287 0.78462625 820.00 1.31836719e-01 -4.96476755e-01 5.13682868e-01 -1.31124180 0.67107546 820.25 2.60253798e-01 -4.82170560e-01 5.47923798e-01 -1.07585305 0.55300380 820.50 2.22248650e-01 -2.80994007e-01 3.58262605e-01 -0.90160588 0.22025585 820.75 -2.40195209e-02 1.26792022e-02 2.71606250e-02 2.65589786 0.00082078 821.00 1.01949435e-01 2.83705477e-01 3.01467221e-01 1.22581669 0.08254473 821.25 1.84289618e-01 5.23137150e-01 5.54648664e-01 1.23209371 0.16988422 821.50 2.26067374e-01 2.40108619e-01 3.29785698e-01 0.81550911 0.05471551 821.75 4.48407904e-01 1.39865666e-01 4.69714863e-01 0.30235287 0.12082256 822.00 3.37081030e-01 -2.01172644e-01 3.92548154e-01 -0.53806911 0.08224377 822.25 5.48493564e-01 -6.39781297e-01 8.42713057e-01 -0.86207131 0.34605129 822.50 2.84452205e-01 -6.42060810e-01 7.02250056e-01 -1.15375375 0.46271564 822.75 2.85446704e-01 -7.33832815e-01 7.87394704e-01 -1.19982541 0.70101454 823.00 1.98522065e-01 -6.26941409e-01 6.57621883e-01 -1.26413361 0.71160927 823.25 1.64749249e-01 -5.46447887e-01 5.70743032e-01 -1.27797199 0.79542746 823.50 7.96223946e-02 -5.49852059e-01 5.55587088e-01 -1.42698899 0.85684809 823.75 4.74757819e-02 -5.86795187e-01 5.88712613e-01 -1.49006527 0.93716914 824.00 -1.77028929e-02 -5.66423884e-01 5.66700458e-01 -1.60203995 0.93426189 824.25 -9.96049653e-02 -5.19038717e-01 5.28509545e-01 -1.76039410 0.93360893 824.50 -1.59050336e-01 -4.57882124e-01 4.84719557e-01 -1.90511810 0.95356149 824.75 -1.69494324e-01 -4.28768321e-01 4.61053792e-01 -1.94724888 0.96514716 825.00 -1.89465198e-01 -3.78971573e-01 4.23693892e-01 -2.03440047 0.95393774 825.25 -2.08905831e-01 -3.61404020e-01 4.17438034e-01 -2.09491194 0.95217392 825.50 -2.29092726e-01 -3.16062756e-01 3.90357712e-01 -2.19799507 0.93069534 825.75 -2.46256730e-01 -3.01153841e-01 3.89019296e-01 -2.25624359 0.94090148 826.00 -3.17059844e-01 -2.85501274e-01 4.26659023e-01 -2.40852074 0.91137486 826.25 -3.63002016e-01 -2.83009112e-01 4.60287541e-01 -2.47939327 0.91575722 826.50 -4.10415396e-01 -1.69408483e-01 4.44004540e-01 -2.75012361 0.79793273 826.75 -4.49219571e-01 -1.78860122e-02 4.49575502e-01 -3.10179793 0.72725524 827.00 -3.53474357e-01 1.79210730e-01 3.96308726e-01 2.67236247 0.80617904 827.25 -3.29459460e-01 2.05751356e-01 3.88429088e-01 2.58334440 0.88750765 827.50 -2.46419847e-01 2.11511235e-01 3.24745660e-01 2.43227849 0.88501607 827.75 -2.04210326e-01 2.07261972e-01 2.90962854e-01 2.34877822 0.87050031 828.00 -1.27528293e-01 1.90581326e-01 2.29313557e-01 2.16051909 0.87828955 828.25 -1.05181091e-01 1.81694918e-01 2.09943100e-01 2.09554797 0.87571032 828.50 -5.23654122e-02 1.51373880e-01 1.60175491e-01 1.90384453 0.84640839 828.75 -5.14249216e-02 1.24368917e-01 1.34581388e-01 1.96287503 0.78789118 829.00 -5.52684095e-02 7.78065115e-02 9.54382016e-02 2.18842253 0.69912928 829.25 -6.84475546e-02 6.14772079e-02 9.20027979e-02 2.40979221 0.68319399 829.50 -9.21296449e-02 4.87002361e-02 1.04209330e-01 2.65532340 0.79590779 829.75 -1.02143813e-01 4.66972534e-02 1.12312030e-01 2.71279083 0.78966101 830.00 -1.42189091e-01 4.09744592e-02 1.47975146e-01 2.86102520 0.84050103 830.25 -1.59991195e-01 3.27821493e-02 1.63315191e-01 2.93949030 0.87055545 830.50 -2.01946227e-01 3.49259403e-02 2.04944139e-01 2.97033993 0.91600751 830.75 -2.38351121e-01 4.88873984e-02 2.43313038e-01 2.93929172 0.91608553 831.00 -3.01252384e-01 9.10631423e-02 3.14714942e-01 2.84804369 0.94563585 831.25 -3.45365600e-01 1.31533368e-01 3.69565184e-01 2.77770088 0.92452506 831.50 -3.79579729e-01 1.88685444e-01 4.23890278e-01 2.68027542 0.95035072 831.75 -3.91778294e-01 2.21942593e-01 4.50276300e-01 2.62616945 0.93562227 832.00 -4.32581003e-01 3.02865498e-01 5.28066126e-01 2.53077547 0.95198380 832.25 -4.89939211e-01 3.67596338e-01 6.12509182e-01 2.49790617 0.91910610 832.50 -5.60938435e-01 5.00969278e-01 7.52078550e-01 2.41260761 0.95604032 832.75 -6.09639491e-01 5.81442134e-01 8.42457871e-01 2.37986381 0.95075168 833.00 -6.58636891e-01 6.85612131e-01 9.50718964e-01 2.33613004 0.95072838 833.25 -7.74865018e-01 7.83466276e-01 1.10192341e+00 2.35067502 0.88681146 833.50 -9.29487449e-01 1.15461652e+00 1.48225714e+00 2.24858974 0.90407692 833.75 -1.08655355e+00 1.30626778e+00 1.69909804e+00 2.26462901 0.84134836 834.00 -1.45464797e+00 1.46468079e+00 2.06428935e+00 2.35275782 0.77910633 834.25 -2.12568654e+00 8.38848475e-01 2.28521553e+00 2.76572870 0.56288529 834.50 -2.20834916e+00 -8.86920374e-02 2.21012947e+00 -3.10145208 0.42549675 834.75 -8.77782718e-01 -1.17772974e+00 1.46886005e+00 -2.21129397 0.40213514 835.00 -5.73228117e-01 -1.49208964e+00 1.59841232e+00 -1.93758915 0.72454348 835.25 -3.94166462e-01 -1.34585180e+00 1.40238521e+00 -1.85570375 0.81032549 835.50 -2.45448916e-01 -1.13251518e+00 1.15880793e+00 -1.78422453 0.83807119 835.75 -1.16408837e-01 -8.90735976e-01 8.98310412e-01 -1.70074821 0.85438783 836.00 -6.70313694e-02 -8.01070588e-01 8.03870196e-01 -1.65427908 0.89649473 836.25 -2.88539645e-02 -6.37170487e-01 6.37823472e-01 -1.61604994 0.88487023 836.50 1.14153791e-02 -6.15816226e-01 6.15922020e-01 -1.55226146 0.91234490 836.75 7.78098898e-02 -6.09965542e-01 6.14908400e-01 -1.44391718 0.85655792 837.00 9.36322568e-02 -6.06919679e-01 6.14099745e-01 -1.41772854 0.79403253 837.25 7.20210706e-02 -6.56037627e-01 6.59979092e-01 -1.46145228 0.80546456 837.50 6.64186828e-02 -6.78337010e-01 6.81580913e-01 -1.47319346 0.81769520 837.75 -4.56915525e-02 -7.27138618e-01 7.28572775e-01 -1.63355129 0.83523575 838.00 -1.42013769e-01 -7.11596923e-01 7.25629445e-01 -1.76777889 0.84118574 838.25 -2.93963351e-01 -7.01273354e-01 7.60393825e-01 -1.96773142 0.88511548 838.50 -3.24060866e-01 -6.73081102e-01 7.47029862e-01 -2.01950131 0.89395692 838.75 -4.73332400e-01 -5.78960532e-01 7.47822745e-01 -2.25615058 0.84564443 839.00 -4.89214096e-01 -5.30067960e-01 7.21319953e-01 -2.31613491 0.84468454 839.25 -4.33823635e-01 -4.58387939e-01 6.31127918e-01 -2.32866952 0.88780317 839.50 -4.48070407e-01 -4.44384248e-01 6.31066121e-01 -2.36032483 0.87132423 839.75 -5.25369127e-01 -3.49004197e-01 6.30727080e-01 -2.55522834 0.87437806 840.00 -5.32767070e-01 -2.78175943e-01 6.01017975e-01 -2.66039483 0.88969865 840.25 -5.37662289e-01 -1.93728174e-01 5.71499206e-01 -2.79575760 0.89274525 840.50 -5.48462289e-01 -1.23564128e-01 5.62209014e-01 -2.92000036 0.89209180 840.75 -4.98886135e-01 -8.18442810e-02 5.05555004e-01 -2.97898707 0.90710209 841.00 -4.91075009e-01 -6.60737341e-02 4.95500154e-01 -3.00784671 0.88265518 841.25 -4.60912848e-01 -5.87346653e-02 4.64640091e-01 -3.01484461 0.84369826 841.50 -4.46085187e-01 -2.52706534e-02 4.46800403e-01 -3.08500330 0.82753260 841.75 -4.84864682e-01 2.55153297e-02 4.85535572e-01 3.08901754 0.88291521 842.00 -5.04883962e-01 8.57257619e-02 5.12110067e-01 2.97340369 0.87581334 842.25 -5.10163957e-01 1.44180562e-01 5.30146487e-01 2.86615967 0.89368470 842.50 -4.67970547e-01 1.97855211e-01 5.08077865e-01 2.74159186 0.85336490 842.75 -3.97234709e-01 2.98865633e-01 4.97107715e-01 2.49657943 0.89990057 843.00 -3.53213774e-01 3.27143198e-01 4.81438098e-01 2.39449472 0.91067490 843.25 -2.88229355e-01 3.19692891e-01 4.30441292e-01 2.30448477 0.88575007 843.50 -2.25754191e-01 3.28358374e-01 3.98477323e-01 2.17309982 0.86333846 843.75 -1.64745628e-01 3.35544761e-01 3.73806646e-01 2.02720160 0.86544269 844.00 -1.24122832e-01 2.78454286e-01 3.04865982e-01 1.99011583 0.76988933 844.25 -7.98522385e-02 2.27602072e-01 2.41203406e-01 1.90822056 0.73482055 844.50 -4.97574247e-02 2.05114427e-01 2.11063330e-01 1.80878289 0.63024375 844.75 -6.13708119e-02 2.22119709e-01 2.30442057e-01 1.84036712 0.67032256 845.00 -4.20988207e-02 2.36594850e-01 2.40311118e-01 1.74688965 0.66055358 845.25 -4.77695183e-02 2.10257060e-01 2.15615301e-01 1.79419977 0.60509366 845.50 -7.23434361e-02 1.83990732e-01 1.97702206e-01 1.94541883 0.56889097 845.75 -6.36914922e-02 1.58689296e-01 1.70993856e-01 1.95247433 0.39194674 846.00 -3.74946039e-03 1.55403919e-01 1.55449144e-01 1.59491884 0.37820093 846.25 -7.77046712e-03 1.47967353e-01 1.48171244e-01 1.62326287 0.52080673 846.50 -1.17367492e-02 1.35614412e-01 1.36121343e-01 1.65712622 0.44395040 846.75 -1.24580038e-02 1.22705063e-01 1.23335860e-01 1.67197765 0.40138220 847.00 7.16033366e-03 1.19240459e-01 1.19455253e-01 1.51081882 0.42374938 847.25 7.55567133e-03 1.04245259e-01 1.04518717e-01 1.49844309 0.36105535 847.50 -2.32665284e-02 1.21835269e-01 1.24036946e-01 1.75949152 0.45564725 847.75 -2.34033410e-02 1.22675615e-01 1.24888042e-01 1.75930538 0.50441583 848.00 -5.84976482e-04 1.18326188e-01 1.18327634e-01 1.57574005 0.38188323 848.25 1.59242449e-02 1.09058299e-01 1.10214764e-01 1.42580508 0.30132872 848.50 2.31122547e-02 1.05638452e-01 1.08137222e-01 1.35540391 0.32948962 848.75 2.21798976e-02 9.10098509e-02 9.36735866e-02 1.33174754 0.25867585 849.00 7.94112678e-02 6.33380000e-02 1.01576827e-01 0.67327253 0.18695140 849.25 8.05093244e-02 9.93138723e-02 1.27847552e-01 0.88959189 0.21200058 849.50 1.18302182e-01 1.01663252e-01 1.55983406e-01 0.70989856 0.42304186 849.75 1.56070093e-01 8.01643684e-02 1.75454267e-01 0.47450264 0.40590936 850.00 2.10628623e-01 -5.20885271e-02 2.16973803e-01 -0.24243618 0.42442182 850.25 2.08086304e-01 -1.20038403e-01 2.40227243e-01 -0.52323726 0.46611432 850.50 2.27379291e-01 -1.86634374e-01 2.94166163e-01 -0.68729963 0.60149475 850.75 1.77186374e-01 -2.38064124e-01 2.96765123e-01 -0.93096606 0.64498257 851.00 1.29848467e-01 -3.27602730e-01 3.52397748e-01 -1.19343221 0.76019408 851.25 8.19927333e-02 -3.74302643e-01 3.83177866e-01 -1.35514791 0.71363660 851.50 -5.79762630e-02 -4.80149630e-01 4.83637172e-01 -1.69096084 0.82136291 851.75 -9.58074866e-02 -5.17785261e-01 5.26574450e-01 -1.75376024 0.81351524 852.00 -1.44718009e-01 -5.66214208e-01 5.84415804e-01 -1.82102808 0.77993920 852.25 -2.81517391e-01 -6.03818606e-01 6.66219897e-01 -2.00706355 0.76805107 852.50 -4.02161549e-01 -6.42661094e-01 7.58120830e-01 -2.12995309 0.88738844 852.75 -4.33721932e-01 -6.85796535e-01 8.11437984e-01 -2.13472451 0.87820710 853.00 -5.36011649e-01 -7.63274740e-01 9.32682592e-01 -2.18303249 0.82467933 853.25 -5.92453123e-01 -7.95954462e-01 9.92242011e-01 -2.21065902 0.78097338 853.50 -6.55934686e-01 -9.30337874e-01 1.13832283e+00 -2.18490349 0.80531835 853.75 -8.91167785e-01 -9.21316620e-01 1.28179731e+00 -2.33956204 0.77420426 854.00 -1.13440063e+00 -1.08687247e+00 1.57103677e+00 -2.37758803 0.77788346 854.25 -1.21381539e+00 -1.04468538e+00 1.60147287e+00 -2.43094094 0.77053680 854.50 -1.24686786e+00 -1.06641027e+00 1.64070422e+00 -2.43404629 0.77228829 854.75 -1.09486207e+00 -1.04053072e+00 1.51043938e+00 -2.38163226 0.73260908 855.00 -1.17842813e+00 -1.09608916e+00 1.60938010e+00 -2.39237933 0.77974739 855.25 -1.14292342e+00 -1.15189830e+00 1.62269641e+00 -2.35228358 0.73961521 855.50 -1.03009810e+00 -1.28202098e+00 1.64459110e+00 -2.24766504 0.80237843 855.75 -7.02348776e-01 -1.19145134e+00 1.38305824e+00 -2.10345212 0.80140509 856.00 -6.41109816e-01 -1.18753475e+00 1.34954088e+00 -2.06582595 0.87722845 856.25 -4.52428965e-01 -1.12202673e+00 1.20980823e+00 -1.95407958 0.77126968 856.50 -2.45377191e-01 -9.63573657e-01 9.94325981e-01 -1.82014973 0.66232349 856.75 -7.26156505e-02 -8.21562190e-01 8.24765097e-01 -1.65895451 0.65506553 857.00 3.60821859e-02 -7.92225593e-01 7.93046855e-01 -1.52528244 0.65540342 857.25 1.06787315e-01 -7.32326301e-01 7.40071174e-01 -1.42599756 0.63571592 857.50 2.90221714e-02 -7.47835923e-01 7.48398860e-01 -1.53200758 0.64196794 857.75 8.01549158e-02 -7.15514073e-01 7.19989722e-01 -1.45923721 0.52720919 858.00 1.86515304e-01 -7.04842079e-01 7.29102404e-01 -1.31210570 0.53449865 858.25 3.50742885e-01 -5.77900132e-01 6.76009714e-01 -1.02529940 0.56734411 858.50 3.46781827e-01 -5.87144726e-01 6.81906566e-01 -1.03729939 0.54447991 858.75 3.64236786e-01 -5.66121539e-01 6.73173108e-01 -0.99908209 0.39621081 859.00 4.58372408e-01 -6.30893852e-01 7.79828389e-01 -0.94247656 0.46050967 859.25 4.75523236e-01 -5.83086774e-01 7.52404502e-01 -0.88665891 0.50787183 859.50 4.36492032e-01 -4.93898978e-01 6.59136932e-01 -0.84702200 0.46936082 859.75 3.62284636e-01 -5.76893388e-01 6.81216660e-01 -1.01004810 0.46588161 860.00 3.14431739e-01 -6.76382812e-01 7.45896123e-01 -1.13564353 0.45730306 860.25 2.51670685e-01 -6.95080030e-01 7.39239056e-01 -1.22340556 0.30508950 860.50 2.30513418e-01 -5.30355656e-01 5.78285014e-01 -1.16078951 0.19630485 860.75 2.10882677e-01 -7.22948607e-01 7.53077813e-01 -1.28697332 0.37134401 861.00 8.74673322e-02 -7.00214876e-01 7.05656720e-01 -1.44652504 0.32322335 861.25 4.82824572e-02 -4.22458036e-01 4.25208170e-01 -1.45700072 0.11957918 861.50 -3.83976045e-02 -2.45217700e-01 2.48205754e-01 -1.72612083 0.05264874 861.75 1.29260855e-01 7.09769482e-03 1.29455575e-01 0.05485477 0.01297901 862.00 6.81990737e-02 1.61800325e-01 1.75586044e-01 1.17189270 0.01693709 862.25 -1.98998877e-01 1.14944981e-01 2.29810578e-01 2.61779443 0.04629771 862.50 -2.60206234e-01 7.26815048e-02 2.70166403e-01 2.86921213 0.11667257 862.75 -3.15899486e-01 1.85887907e-01 3.66533490e-01 2.60971649 0.32559789 863.00 -3.36127047e-01 2.15066391e-01 3.99042534e-01 2.57239538 0.40481347 863.25 -4.42163216e-01 5.83139892e-03 4.42201668e-01 3.12840508 0.45929866 863.50 -3.92035659e-01 -3.99052611e-02 3.94061402e-01 -3.04015216 0.40936329 863.75 -2.61671875e-01 2.54615310e-02 2.62907702e-01 3.04459473 0.27781399 864.00 -2.06875278e-01 3.37346057e-04 2.06875553e-01 3.13996198 0.21042423 864.25 -1.69885512e-01 4.03660770e-03 1.69933462e-01 3.11783637 0.25824801 864.50 -1.81583899e-01 -3.36788929e-02 1.84680752e-01 -2.95820367 0.28678658 864.75 -1.36540007e-01 -9.07038916e-02 1.63921840e-01 -2.55522845 0.26616273 865.00 -1.22133641e-01 -6.42312241e-02 1.37993755e-01 -2.65743305 0.20016602 865.25 -1.32854171e-01 -8.05260529e-02 1.55353391e-01 -2.59668264 0.26283015 865.50 -5.94941237e-02 -8.89448068e-02 1.07008081e-01 -2.16033528 0.07977530 865.75 -3.18560450e-02 -1.33928496e-01 1.37664990e-01 -1.80431556 0.10784361 866.00 7.54118510e-03 -1.52768326e-01 1.52954342e-01 -1.52147283 0.11099642 866.25 5.01087767e-02 -1.84555411e-01 1.91236997e-01 -1.30567694 0.17487668 866.50 7.46735218e-02 -2.37835203e-01 2.49282408e-01 -1.26657126 0.16863342 866.75 -1.43214524e-02 -2.54026248e-01 2.54429634e-01 -1.62711455 0.15880556 867.00 2.08087914e-02 -2.26482408e-01 2.27436336e-01 -1.47917538 0.16590210 867.25 2.57746683e-02 -3.31824718e-01 3.32824243e-01 -1.49327643 0.31303410 867.50 -2.91576934e-02 -3.38930955e-01 3.40182839e-01 -1.65661345 0.26444710 867.75 -1.40543906e-01 -3.17049607e-01 3.46804041e-01 -1.98805355 0.25698337 868.00 -1.06688926e-01 -3.22383263e-01 3.39578408e-01 -1.89038968 0.36514666 868.25 -1.32404393e-01 -3.14034649e-01 3.40805933e-01 -1.96980359 0.43770743 868.50 -2.31162437e-01 -2.66107033e-01 3.52489752e-01 -2.28603687 0.51830230 868.75 -2.84769055e-01 -2.73566980e-01 3.94882650e-01 -2.37625512 0.60409379 869.00 -3.61302282e-01 -2.00087083e-01 4.13006271e-01 -2.63584115 0.65252846 869.25 -3.78143017e-01 -2.12485538e-01 4.33753669e-01 -2.62964507 0.61494888 869.50 -4.61413284e-01 -2.14725824e-01 5.08929659e-01 -2.70603450 0.74069636 869.75 -4.46491555e-01 -1.93706512e-01 4.86700032e-01 -2.73225718 0.74303948 870.00 -4.17125738e-01 -2.16946247e-01 4.70169709e-01 -2.66199625 0.73387918 870.25 -4.08988775e-01 -1.78774604e-01 4.46354318e-01 -2.72950648 0.70996693 870.50 -5.03840571e-01 -8.26237415e-02 5.10570273e-01 -2.97905150 0.73989697 870.75 -4.99240765e-01 -8.18891879e-02 5.05912226e-01 -2.97901296 0.75941492 871.00 -4.78126660e-01 -9.34074577e-02 4.87165327e-01 -2.94866131 0.80255794 871.25 -4.37901265e-01 -6.97413362e-02 4.43420085e-01 -2.98365637 0.79514840 871.50 -3.81560741e-01 -3.92850031e-02 3.83577776e-01 -3.03899545 0.75171462 871.75 -3.71378781e-01 -3.46330350e-02 3.72990142e-01 -3.04860630 0.72223681 872.00 -3.85759596e-01 -4.38795732e-02 3.88247192e-01 -3.02833097 0.79531047 872.25 -3.89526145e-01 -4.35956529e-02 3.91958159e-01 -3.03013677 0.81113347 872.50 -3.72803830e-01 -8.64656123e-02 3.82699618e-01 -2.91368890 0.86806552 872.75 -3.62349924e-01 -9.25415499e-02 3.73980489e-01 -2.89154492 0.86059698 873.00 -3.64121343e-01 -1.39541017e-01 3.89943647e-01 -2.77562912 0.84383409 873.25 -3.80587967e-01 -1.34287419e-01 4.03584330e-01 -2.80238823 0.84627405 873.50 -3.84121015e-01 -9.64607098e-02 3.96047500e-01 -2.89555956 0.86200203 873.75 -3.63889709e-01 -1.10485548e-01 3.80293014e-01 -2.84681467 0.81434362 874.00 -3.15299694e-01 -1.66503966e-01 3.56563413e-01 -2.65573296 0.80156927 874.25 -3.79338226e-01 -2.07303651e-01 4.32287281e-01 -2.64145007 0.75383255 874.50 -4.35269756e-01 -2.55715214e-01 5.04826734e-01 -2.61042488 0.76262609 874.75 -4.51738329e-01 -2.38795188e-01 5.10970312e-01 -2.65531678 0.73199436 875.00 -5.16483157e-01 -2.30541339e-01 5.65600707e-01 -2.72176355 0.81773247 875.25 -5.33465495e-01 -2.34261647e-01 5.82635352e-01 -2.72781342 0.80401000 875.50 -5.87169802e-01 -2.47268882e-01 6.37110883e-01 -2.74301308 0.80455574 875.75 -6.93059770e-01 -2.67996878e-01 7.43070771e-01 -2.77261583 0.73821485 876.00 -6.97684575e-01 -2.85550605e-01 7.53858683e-01 -2.75310919 0.70446598 876.25 -7.50648070e-01 -2.58297489e-01 7.93845147e-01 -2.81018421 0.67988394 876.50 -7.65544137e-01 -2.17718954e-01 7.95901608e-01 -2.86451068 0.65581394 876.75 -8.02612624e-01 -1.71086584e-01 8.20644651e-01 -2.93157386 0.65117745 877.00 -8.24143210e-01 -2.57752041e-02 8.24546173e-01 -3.11032769 0.58276975 877.25 -8.45423788e-01 6.35382710e-03 8.45447664e-01 3.13407724 0.54230282 877.50 -9.36781599e-01 1.30482001e-01 9.45825204e-01 3.00319555 0.53637762 877.75 -1.05432661e+00 2.71329788e-01 1.08868014e+00 2.88970943 0.57903335 878.00 -1.01066990e+00 4.39931803e-01 1.10226750e+00 2.73104091 0.58886940 878.25 -5.45644131e-01 7.92802754e-01 9.62425958e-01 2.17359075 0.49923155 878.50 -5.26897782e-01 8.64969338e-01 1.01281451e+00 2.11791806 0.59284681 878.75 -4.42411891e-01 6.22136038e-01 7.63401291e-01 2.18894487 0.46161766 879.00 -2.72709596e-01 4.17354836e-01 4.98553491e-01 2.14957470 0.31145075 879.25 -2.22127058e-01 3.55482852e-01 4.19175963e-01 2.12929505 0.29695241 879.50 -2.51946964e-01 2.90552688e-01 3.84575268e-01 2.28515158 0.33815222 879.75 -4.33495311e-01 2.82689140e-01 5.17524236e-01 2.56373149 0.58393486 880.00 -5.17672121e-01 2.77163684e-01 5.87200249e-01 2.65002466 0.63240569 880.25 -4.99509615e-01 2.78829475e-01 5.72062699e-01 2.63247077 0.67893012 880.50 -5.29516469e-01 2.85419139e-01 6.01541168e-01 2.64721966 0.72290667 880.75 -5.49463274e-01 3.16905628e-01 6.34302032e-01 2.61844053 0.79202795 881.00 -4.89032051e-01 3.20649787e-01 5.84780842e-01 2.56123303 0.71271466 881.25 -5.21329757e-01 2.54537693e-01 5.80150113e-01 2.68739157 0.62360242 881.50 -5.83155125e-01 1.98780339e-01 6.16103500e-01 2.81307412 0.59259289 881.75 -5.38400944e-01 1.47508160e-01 5.58242093e-01 2.87418004 0.45864506 882.00 -4.50491222e-01 6.13097477e-02 4.54644065e-01 3.00632837 0.34770070 882.25 -2.95184108e-01 5.28218563e-02 2.99872984e-01 2.96452135 0.25144354 882.50 -1.86915988e-01 -1.29979741e-03 1.86920507e-01 -3.13463885 0.09322947 882.75 -1.94398853e-03 9.57233927e-02 9.57431303e-02 1.59110193 0.01149741 883.00 4.45083676e-02 1.10738736e-01 1.19348492e-01 1.18863389 0.02346147 883.25 1.51430030e-01 1.05414314e-01 1.84508080e-01 0.60812093 0.08738467 883.50 2.24713371e-01 2.15092691e-01 3.11064246e-01 0.76352683 0.26760428 883.75 2.69274203e-01 2.58432939e-01 3.73224035e-01 0.76485696 0.46407067 884.00 2.57213201e-01 2.89428310e-01 3.87204568e-01 0.84426287 0.50328243 884.25 1.91663981e-01 2.96141965e-01 3.52753661e-01 0.99638985 0.61758892 884.50 1.07762378e-01 3.09872798e-01 3.28076029e-01 1.23611553 0.59109144 884.75 3.37812317e-02 2.82859432e-01 2.84869496e-01 1.45193168 0.52131584 885.00 5.74284153e-02 2.58966480e-01 2.65257724e-01 1.35256786 0.50147744 885.25 7.74901205e-02 2.40789117e-01 2.52950820e-01 1.25944569 0.44331274 885.50 5.52901562e-02 2.14922612e-01 2.21920550e-01 1.31900012 0.31871589 885.75 2.50633692e-02 2.85303703e-01 2.86402471e-01 1.48317324 0.52619343 886.00 1.00428544e-02 3.14396948e-01 3.14557307e-01 1.53886395 0.53160573 886.25 -9.70261866e-03 2.46731152e-01 2.46921855e-01 1.61010073 0.46075695 886.50 -2.32891162e-03 2.65099502e-01 2.65109731e-01 1.57958115 0.53603226 886.75 -4.78573089e-02 2.85812377e-01 2.89791368e-01 1.73670035 0.70280379 887.00 -3.33339405e-02 3.16525033e-01 3.18275429e-01 1.67572175 0.76775340 887.25 -1.32367729e-02 3.16867103e-01 3.17143458e-01 1.61254595 0.82333815 887.50 -1.14090699e-02 3.28586557e-01 3.28784569e-01 1.60550404 0.78969381 887.75 -7.21518815e-03 2.96685797e-01 2.96773518e-01 1.59511082 0.79499400 888.00 6.80327832e-03 2.94198652e-01 2.94277304e-01 1.54767567 0.76961879 888.25 -9.81812164e-04 2.99264471e-01 2.99266082e-01 1.57407707 0.79640977 888.50 -5.91049822e-03 2.90111869e-01 2.90172071e-01 1.59116668 0.77138135 888.75 1.01141370e-02 2.69039418e-01 2.69229464e-01 1.53322051 0.75511505 889.00 -7.22319822e-03 2.59760994e-01 2.59861403e-01 1.59859626 0.74059694 889.25 8.37168834e-03 2.72729401e-01 2.72857859e-01 1.54011001 0.77305404 889.50 4.63884371e-02 2.33380987e-01 2.37946575e-01 1.37458663 0.67399402 889.75 5.59576395e-02 1.92695690e-01 2.00656139e-01 1.28817566 0.64514297 890.00 5.15448811e-02 1.86570805e-01 1.93560172e-01 1.30124499 0.67486606 890.25 3.29869060e-02 1.57906595e-01 1.61315308e-01 1.36485658 0.56966278 890.50 5.00405875e-03 9.59835098e-02 9.61138635e-02 1.51870892 0.28496339 890.75 -3.14122456e-02 6.06746596e-02 6.83238135e-02 2.04851613 0.17544709 891.00 -3.89887663e-02 1.60733345e-02 4.21719810e-02 2.75056601 0.06225980 891.25 -6.46579198e-02 1.20579006e-02 6.57726354e-02 2.95722289 0.14741829 891.50 -1.14749598e-01 2.32789055e-02 1.17087051e-01 2.94144190 0.47340558 891.75 -1.30343809e-01 1.34687079e-02 1.31037836e-01 3.03862593 0.47963338 892.00 -1.76409208e-01 9.19070820e-03 1.76648458e-01 3.08954091 0.59355437 892.25 -1.96472754e-01 2.20304535e-02 1.97704032e-01 3.02992927 0.64997837 892.50 -2.36538859e-01 5.01986715e-02 2.41806820e-01 2.93247358 0.72867610 892.75 -2.27747306e-01 6.85154425e-02 2.37830195e-01 2.84936563 0.71043286 893.00 -2.23553216e-01 1.11761177e-01 2.49933194e-01 2.67800027 0.76849208 893.25 -2.35845968e-01 1.07671644e-01 2.59261458e-01 2.71331856 0.77750406 893.50 -2.54743547e-01 9.29206597e-02 2.71161435e-01 2.79182820 0.84291333 893.75 -2.57936860e-01 1.06205084e-01 2.78946130e-01 2.75099957 0.84812148 894.00 -2.27979427e-01 1.11546468e-01 2.53805503e-01 2.68655531 0.87165021 894.25 -2.42394525e-01 1.04005841e-01 2.63765655e-01 2.73627409 0.88247236 894.50 -2.62128202e-01 1.15576915e-01 2.86477255e-01 2.72631734 0.91099178 894.75 -2.53842023e-01 9.77624690e-02 2.72017046e-01 2.77396960 0.86170374 895.00 -2.32868012e-01 9.55915224e-02 2.51724552e-01 2.75207038 0.82262996 895.25 -2.71932236e-01 9.01508380e-02 2.86486151e-01 2.82147544 0.84356233 895.50 -2.84215102e-01 7.84326139e-02 2.94838768e-01 2.87233215 0.88834632 895.75 -3.10197590e-01 8.21415908e-02 3.20889055e-01 2.88272999 0.88881864 896.00 -3.30169186e-01 9.52813018e-02 3.43642573e-01 2.86064256 0.91880728 896.25 -3.35875294e-01 1.14355028e-01 3.54808802e-01 2.81343407 0.91178379 896.50 -3.37859063e-01 1.25961303e-01 3.60575923e-01 2.78473280 0.92444604 896.75 -3.23825469e-01 1.36593981e-01 3.51455331e-01 2.74242402 0.92227626 897.00 -3.16757762e-01 1.48216168e-01 3.49719191e-01 2.70393970 0.92116134 897.25 -3.38489964e-01 1.53703795e-01 3.71753026e-01 2.71534542 0.93648682 897.50 -3.44717451e-01 1.57497190e-01 3.78992725e-01 2.71302563 0.95841522 897.75 -3.57952167e-01 1.56682797e-01 3.90741926e-01 2.72899763 0.94050926 898.00 -3.52145212e-01 1.64452012e-01 3.88652435e-01 2.70469134 0.94155946 898.25 -3.47485226e-01 1.52067734e-01 3.79302752e-01 2.72907848 0.91402583 898.50 -3.65522080e-01 1.44917515e-01 3.93201573e-01 2.76413550 0.93821464 898.75 -3.79031316e-01 1.26061670e-01 3.99444968e-01 2.82051209 0.93547278 899.00 -3.90485140e-01 1.24650418e-01 4.09898001e-01 2.83259799 0.94072452 899.25 -4.33526001e-01 1.45946240e-01 4.57433163e-01 2.81686067 0.91619055 899.50 -4.57121427e-01 1.57241579e-01 4.83409674e-01 2.81028904 0.92662726 899.75 -4.29666635e-01 2.03496303e-01 4.75419985e-01 2.69927545 0.88363125 900.00 -4.53659949e-01 2.28695538e-01 5.08044288e-01 2.67466066 0.88589044 900.25 -5.31216935e-01 2.20684942e-01 5.75233236e-01 2.74785333 0.91155175 900.50 -5.14986760e-01 2.38033303e-01 5.67336951e-01 2.70862937 0.89980971 900.75 -4.95702545e-01 3.18474116e-01 5.89191629e-01 2.57052901 0.88563709 901.00 -4.98048216e-01 3.35217136e-01 6.00352025e-01 2.54917584 0.90554849 901.25 -4.46983118e-01 4.15504228e-01 6.10276717e-01 2.39267610 0.88572875 901.50 -4.32734106e-01 4.31418036e-01 6.11048548e-01 2.35771745 0.89109477 901.75 -3.87765186e-01 4.50293939e-01 5.94244454e-01 2.28172109 0.91423753 902.00 -3.63822090e-01 4.47698668e-01 5.76888734e-01 2.25320292 0.92590448 902.25 -3.68696633e-01 3.99382734e-01 5.43547400e-01 2.31626399 0.93978115 902.50 -3.48593672e-01 3.66106043e-01 5.05520704e-01 2.33169627 0.93257644 902.75 -3.33079566e-01 3.70094779e-01 4.97907766e-01 2.30360287 0.90731543 903.00 -3.12435827e-01 3.88642843e-01 4.98657603e-01 2.24791993 0.90260377 903.25 -3.01417640e-01 4.11520858e-01 5.10100001e-01 2.20296921 0.92940328 903.50 -3.04409084e-01 4.23635448e-01 5.21662614e-01 2.19387285 0.92609947 903.75 -2.80712962e-01 4.18704439e-01 5.04096394e-01 2.16140135 0.93493342 904.00 -2.82692580e-01 4.21377146e-01 5.07418756e-01 2.16170868 0.95243888 904.25 -2.73000683e-01 4.47936310e-01 5.24572503e-01 2.11814500 0.96478199 904.50 -2.62570073e-01 4.59256459e-01 5.29017522e-01 2.09016862 0.96050180 904.75 -2.35022281e-01 4.62699538e-01 5.18966603e-01 2.04077347 0.95590380 905.00 -2.12511143e-01 4.65518291e-01 5.11730657e-01 1.99904612 0.94820808 905.25 -1.78385845e-01 4.63933734e-01 4.97047301e-01 1.93787588 0.93521909 905.50 -1.65573627e-01 4.63416630e-01 4.92107304e-01 1.91394980 0.95193674 905.75 -1.59917835e-01 4.38398955e-01 4.66655502e-01 1.92057434 0.95997671 906.00 -1.67456895e-01 4.31378578e-01 4.62741061e-01 1.94108049 0.95231433 906.25 -1.90426362e-01 4.62233123e-01 4.99921654e-01 1.96157923 0.95009833 906.50 -1.66334757e-01 4.86033419e-01 5.13707831e-01 1.90053155 0.93268676 906.75 -1.11378429e-01 5.14281764e-01 5.26204226e-01 1.78407343 0.94010690 907.00 -8.18280737e-02 5.14267063e-01 5.20736446e-01 1.72858945 0.94332184 907.25 -8.33115130e-02 5.11957898e-01 5.18692296e-01 1.73211346 0.95460082 907.50 -7.88790560e-02 5.10749578e-01 5.16804641e-01 1.72402360 0.92399610 907.75 -5.16320094e-02 5.00740849e-01 5.03395731e-01 1.67354446 0.90434582 908.00 -3.15895037e-02 5.43588771e-01 5.44505875e-01 1.62884391 0.92079097 908.25 -1.59864228e-02 5.69576599e-01 5.69800902e-01 1.59885616 0.92717950 908.50 5.37057443e-02 5.64023907e-01 5.66575038e-01 1.47586363 0.84767958 908.75 1.01096113e-01 5.36720971e-01 5.46159157e-01 1.38461888 0.83235707 909.00 1.45524083e-01 5.38372706e-01 5.57693849e-01 1.30680154 0.66827729 909.25 1.85386590e-01 5.82820887e-01 6.11594942e-01 1.26283145 0.59219590 909.50 3.34443718e-01 3.45488164e-01 4.80847867e-01 0.80164019 0.38532092 909.75 2.82193950e-01 2.34664380e-01 3.67016071e-01 0.69369746 0.26003449 910.00 1.83096635e-01 1.94852887e-01 2.67379927e-01 0.81649349 0.18845718 910.25 1.83606945e-01 1.69929289e-01 2.50174886e-01 0.74672932 0.18417921 910.50 2.09021397e-01 1.37463490e-01 2.50172252e-01 0.58173619 0.23151928 910.75 1.57035941e-01 6.87214475e-02 1.71414480e-01 0.41250784 0.12568077 911.00 1.64310085e-01 -1.12295012e-02 1.64693369e-01 -0.06823724 0.15056662 911.25 2.15194614e-01 -2.54330286e-02 2.16692318e-01 -0.11764047 0.23320374 911.50 2.81454241e-01 -1.48702521e-01 3.18322054e-01 -0.48605891 0.45808032 911.75 2.66637998e-01 -1.80504924e-01 3.21990450e-01 -0.59509923 0.53507867 912.00 2.54755828e-01 -2.52923029e-01 3.58985501e-01 -0.78178803 0.50568010 912.25 2.35572692e-01 -2.36653225e-01 3.33915022e-01 -0.78768633 0.45104138 912.50 2.56660635e-01 -3.51756638e-01 4.35439334e-01 -0.94044433 0.44731341 912.75 2.15731297e-01 -4.09020533e-01 4.62425982e-01 -1.08544323 0.48017276 913.00 7.74871419e-02 -3.94147389e-01 4.01691948e-01 -1.37667758 0.44547802 913.25 -2.05195661e-02 -4.25926254e-01 4.26420247e-01 -1.61893544 0.40646532 913.50 -1.35578707e-01 -5.33970293e-01 5.50913659e-01 -1.81944862 0.40214991 913.75 -2.31125666e-02 -4.89684139e-01 4.90229280e-01 -1.61796025 0.30081006 914.00 1.49612237e-02 -5.01253514e-01 5.01476742e-01 -1.54095757 0.24495347 914.25 -1.60748890e-01 -5.77953494e-01 5.99892029e-01 -1.84207445 0.30505119 914.50 -1.92764278e-01 -4.98549335e-01 5.34518013e-01 -1.93974168 0.24246259 914.75 -2.91654680e-01 -5.72630694e-01 6.42626146e-01 -2.04187545 0.35313410 915.00 -4.07172003e-01 -5.16105351e-01 6.57384038e-01 -2.23875193 0.42855610 915.25 -3.41319882e-01 -3.54278920e-01 4.91947980e-01 -2.33756660 0.31872850 915.50 -3.92993690e-01 -2.64539338e-01 4.73735266e-01 -2.54912265 0.47897467 915.75 -3.82187890e-01 -1.99577913e-01 4.31159978e-01 -2.66034442 0.49640360 916.00 -3.22376797e-01 -1.82873716e-01 3.70634045e-01 -2.62558935 0.47632811 916.25 -2.54379895e-01 -9.83937233e-02 2.72746138e-01 -2.77251856 0.39145285 916.50 -1.90458199e-01 -1.53614806e-02 1.91076688e-01 -3.06111148 0.50787956 916.75 -1.36206479e-01 9.60733343e-03 1.36544886e-01 3.07117421 0.38256773 917.00 -6.91643336e-02 4.30167872e-02 8.14502855e-02 2.58518929 0.28389100 917.25 -3.82705623e-02 7.57532524e-02 8.48716160e-02 2.03859548 0.31751523 917.50 -2.23771178e-02 8.77325516e-02 9.05413497e-02 1.82053221 0.50718974 917.75 -1.96297885e-02 1.00453465e-01 1.02353443e-01 1.76377625 0.54549026 918.00 -1.51106851e-02 1.21625512e-01 1.22560589e-01 1.69440239 0.69244950 918.25 -1.55611445e-02 1.24757027e-01 1.25723765e-01 1.69488705 0.67083158 918.50 -1.98049865e-02 1.20658012e-01 1.22272619e-01 1.73348708 0.65942880 918.75 -2.59449275e-02 1.06598340e-01 1.09710279e-01 1.80954383 0.59515182 919.00 -4.09276335e-02 1.07429200e-01 1.14961316e-01 1.93479336 0.65433520 919.25 -6.61869424e-02 9.46000782e-02 1.15455126e-01 2.18128734 0.64906609 919.50 -8.58509126e-02 9.77842685e-02 1.30123566e-01 2.29130169 0.73755089 919.75 -1.24795802e-01 1.07721624e-01 1.64857334e-01 2.42949475 0.87351632 920.00 -1.41290448e-01 1.24783122e-01 1.88504159e-01 2.41815553 0.91906718 920.25 -1.63636357e-01 1.71475578e-01 2.37024748e-01 2.33280591 0.94130054 920.50 -1.66707231e-01 1.90521486e-01 2.53159510e-01 2.28962910 0.95601849 920.75 -1.80233970e-01 2.15013464e-01 2.80562068e-01 2.26842632 0.96213289 921.00 -1.86587167e-01 2.44635544e-01 3.07670799e-01 2.22238541 0.95959586 921.25 -1.60714470e-01 3.01571465e-01 3.41722825e-01 2.06043439 0.95216553 921.50 -1.36188738e-01 3.26109363e-01 3.53404427e-01 1.96639673 0.95231670 921.75 -7.03670094e-02 3.49693603e-01 3.56703142e-01 1.76936926 0.94567548 922.00 -3.73392007e-02 3.60255610e-01 3.62185478e-01 1.67407397 0.95366821 922.25 2.36198897e-02 3.54503056e-01 3.55289060e-01 1.50426649 0.94974180 922.50 4.32171019e-02 3.28186247e-01 3.31019533e-01 1.43986500 0.92353594 922.75 7.45475078e-02 2.71622626e-01 2.81666792e-01 1.30293920 0.92617702 923.00 7.58782489e-02 2.52544988e-01 2.63697705e-01 1.27892272 0.90018148 923.25 6.95207673e-02 2.44851982e-01 2.54530214e-01 1.29414728 0.90500674 923.50 8.83043214e-02 2.31822571e-01 2.48071275e-01 1.20685142 0.90784798 923.75 8.37647725e-02 2.19715651e-01 2.35141456e-01 1.20656472 0.92465991 924.00 7.21332605e-02 2.17732677e-01 2.29370281e-01 1.25088341 0.88703218 924.25 1.04318176e-01 2.17728892e-01 2.41429394e-01 1.12399215 0.82512875 924.50 1.10748641e-01 2.28638503e-01 2.54048866e-01 1.11972006 0.84929395 924.75 1.43481213e-01 2.56831280e-01 2.94192394e-01 1.06132913 0.83960592 925.00 1.71847605e-01 2.72654158e-01 3.22291621e-01 1.00841142 0.77571620 925.25 2.56009862e-01 2.89754441e-01 3.86650598e-01 0.84714950 0.75946620 925.50 2.82417140e-01 1.30998068e-01 3.11319667e-01 0.43430844 0.61729016 925.75 3.07253327e-01 -3.36162680e-02 3.09086817e-01 -0.10897552 0.72050748 926.00 2.39177541e-01 -7.04255800e-02 2.49330420e-01 -0.28635636 0.65830521 926.25 1.94213400e-01 -9.62506859e-02 2.16755714e-01 -0.46011532 0.78423263 926.50 1.75219590e-01 -1.08247577e-01 2.05959808e-01 -0.55339228 0.78909516 926.75 1.58086839e-01 -9.70475153e-02 1.85498434e-01 -0.55056828 0.78918813 927.00 1.31647919e-01 -8.50197508e-02 1.56714813e-01 -0.57342518 0.77999633 927.25 1.23927651e-01 -8.12068211e-02 1.48164134e-01 -0.58007528 0.78569696 927.50 1.13358263e-01 -7.43514112e-02 1.35566323e-01 -0.58050999 0.77158955 927.75 1.05051864e-01 -6.18231322e-02 1.21893370e-01 -0.53192148 0.73013913 928.00 1.19062276e-01 -6.20718353e-02 1.34271137e-01 -0.48057289 0.73284079 928.25 1.22717258e-01 -4.47751615e-02 1.30630550e-01 -0.34985521 0.74046221 928.50 1.39466946e-01 -2.05243293e-02 1.40969065e-01 -0.14611391 0.64136199 928.75 1.41043503e-01 -6.04603670e-03 1.41173029e-01 -0.04284024 0.59654736 929.00 1.75438906e-01 5.67641077e-03 1.75530713e-01 0.03234420 0.55792017 929.25 1.97459334e-01 1.61452842e-02 1.98118295e-01 0.08158362 0.54602398 929.50 2.20151026e-01 3.52349463e-02 2.22952855e-01 0.15870302 0.50314982 929.75 2.60996144e-01 2.95118283e-02 2.62659352e-01 0.11259556 0.50102146 930.00 3.14583272e-01 -1.18772703e-01 3.36258219e-01 -0.36100939 0.59934171 930.25 2.98129908e-01 -2.01427936e-01 3.59798076e-01 -0.59418793 0.70181929 930.50 2.03881557e-01 -2.00496055e-01 2.85948173e-01 -0.77702623 0.59622418 930.75 1.80478753e-01 -1.84316185e-01 2.57963247e-01 -0.79591720 0.56849581 931.00 1.72587220e-01 -1.72545102e-01 2.44045408e-01 -0.78527613 0.64797503 931.25 2.01553962e-01 -1.40064702e-01 2.45442703e-01 -0.60731118 0.65314048 931.50 2.62783377e-01 -1.14527154e-01 2.86655842e-01 -0.41100236 0.78747070 931.75 3.10596298e-01 -1.17789258e-01 3.32181230e-01 -0.36247913 0.82347307 932.00 4.51619072e-01 -1.85850506e-01 4.88364819e-01 -0.39039822 0.81599332 932.25 4.66315702e-01 -2.98128162e-01 5.53471530e-01 -0.56883552 0.81451839 932.50 4.02601862e-01 -4.76112848e-01 6.23515600e-01 -0.86886122 0.74057814 932.75 2.75742870e-01 -5.69084174e-01 6.32369297e-01 -1.11959471 0.75856237 933.00 1.30849324e-01 -6.06567185e-01 6.20520181e-01 -1.35833105 0.80602430 933.25 5.89127366e-02 -5.74944882e-01 5.77955300e-01 -1.46868594 0.80948727 933.50 -2.86842185e-03 -5.09043338e-01 5.09051420e-01 -1.57643119 0.85746641 933.75 7.78540688e-03 -4.53820057e-01 4.53886832e-01 -1.55364274 0.82536530 934.00 -2.27383969e-02 -3.87331489e-01 3.87998347e-01 -1.62943429 0.81688641 934.25 -3.64824085e-02 -3.74424901e-01 3.76198050e-01 -1.66792558 0.82501388 934.50 4.39475379e-03 -3.42958098e-01 3.42986255e-01 -1.55798277 0.81582525 934.75 -6.78833228e-03 -3.69694198e-01 3.69756516e-01 -1.58915628 0.86419188 935.00 -4.47036267e-02 -3.45731133e-01 3.48609281e-01 -1.69938458 0.84481920 935.25 -5.27747325e-02 -3.23374235e-01 3.27652359e-01 -1.73257032 0.88550528 935.50 -5.48451460e-02 -3.10165612e-01 3.14977296e-01 -1.74581256 0.89323947 935.75 -5.85529248e-02 -2.85975095e-01 2.91907862e-01 -1.77275340 0.82340363 936.00 -4.83489530e-02 -2.49718935e-01 2.54356379e-01 -1.76204353 0.78900866 936.25 -3.66517587e-02 -2.22505258e-01 2.25503750e-01 -1.73405338 0.72981230 936.50 -7.35803560e-02 -1.74174971e-01 1.89079320e-01 -1.97050580 0.64924831 936.75 -7.14130003e-02 -1.43392138e-01 1.60190892e-01 -2.03286342 0.58935151 937.00 -5.19686616e-02 -1.30629110e-01 1.40587006e-01 -1.94943381 0.54932362 937.25 -1.77210294e-02 -9.99861988e-02 1.01544448e-01 -1.74620952 0.32787782 937.50 2.70351932e-03 -5.57404975e-02 5.58060218e-02 -1.52233242 0.20936668 937.75 2.34360834e-02 -4.11826696e-02 4.73841986e-02 -1.05342522 0.13367242 938.00 3.51535047e-02 -4.24521554e-03 3.54089078e-02 -0.12018027 0.09308445 938.25 6.72984082e-02 -1.76578299e-03 6.73215696e-02 -0.02623209 0.19645004 938.50 1.12321002e-01 3.80360738e-03 1.12385385e-01 0.03385079 0.43665071 938.75 1.86238978e-01 -1.39865861e-02 1.86763437e-01 -0.07495950 0.60241241 939.00 2.19025456e-01 -5.10265013e-02 2.24890760e-01 -0.22888794 0.66130531 939.25 2.13607881e-01 -1.19132513e-01 2.44583079e-01 -0.50874782 0.60776393 939.50 2.11009208e-01 -1.51236424e-01 2.59609980e-01 -0.62186549 0.67019519 939.75 1.80569463e-01 -1.66291093e-01 2.45475169e-01 -0.74425681 0.72670233 940.00 1.65989649e-01 -1.62031468e-01 2.31962842e-01 -0.77333190 0.81926590 940.25 1.36625221e-01 -1.46615249e-01 2.00405794e-01 -0.82065403 0.80154968 940.50 1.32286256e-01 -1.22684300e-01 1.80419209e-01 -0.74775687 0.75557994 940.75 9.71728148e-02 -5.85849751e-02 1.13466979e-01 -0.54254524 0.43137155 941.00 9.81884160e-02 -1.04670429e-02 9.87447418e-02 -0.10620053 0.37631878 941.25 1.31532643e-01 4.59930128e-02 1.39342001e-01 0.33638076 0.44128748 941.50 1.51781832e-01 7.21972738e-02 1.68077871e-01 0.44399061 0.49007295 941.75 1.83065458e-01 1.54429956e-01 2.39502763e-01 0.70075381 0.55399518 942.00 2.18278280e-01 1.97996093e-01 2.94699610e-01 0.73671354 0.64458321 942.25 2.86412432e-01 2.91280587e-01 4.08505155e-01 0.79382485 0.63590968 942.50 3.11417548e-01 3.84479183e-01 4.94777860e-01 0.89000413 0.66436693 942.75 3.60020363e-01 4.16915265e-01 5.50847529e-01 0.85849756 0.70783044 943.00 3.38652336e-01 4.67762571e-01 5.77483530e-01 0.94415481 0.66986616 943.25 3.93288377e-01 5.27625096e-01 6.58075976e-01 0.93024983 0.66606299 943.50 4.23889216e-01 5.96888603e-01 7.32091573e-01 0.95328094 0.72444808 943.75 4.86898033e-01 6.68771968e-01 8.27239772e-01 0.94149322 0.79992406 944.00 5.06660059e-01 6.88929345e-01 8.55177208e-01 0.93668471 0.81295434 944.25 5.59977478e-01 7.23099794e-01 9.14575359e-01 0.91185344 0.79125080 944.50 7.03622526e-01 7.20094467e-01 1.00678732e+00 0.79696732 0.75504532 944.75 8.38571233e-01 8.34424298e-01 1.18299012e+00 0.78291942 0.71329865 945.00 7.88015429e-01 7.13214161e-01 1.06284653e+00 0.73561267 0.65005860 945.25 6.47756529e-01 5.30051529e-01 8.36984554e-01 0.68579324 0.62961134 945.50 6.98295851e-01 5.13451712e-01 8.66746650e-01 0.63402168 0.60223774 945.75 8.43119050e-01 7.00205589e-01 1.09596423e+00 0.69306046 0.75509866 946.00 7.45598345e-01 6.96521029e-01 1.02032271e+00 0.75137991 0.76286751 946.25 7.04604547e-01 5.99167490e-01 9.24915806e-01 0.70470300 0.77440034 946.50 6.93633222e-01 6.68291963e-01 9.63193228e-01 0.76679337 0.83726069 946.75 6.51040043e-01 7.17232980e-01 9.68646625e-01 0.83373747 0.86981674 947.00 6.79764500e-01 6.94588231e-01 9.71870663e-01 0.79618372 0.86197603 947.25 7.18937091e-01 7.54960618e-01 1.04251430e+00 0.80983429 0.84043168 947.50 6.51618018e-01 7.61469861e-01 1.00221873e+00 0.86298099 0.84672794 947.75 6.19001265e-01 7.29483252e-01 9.56717503e-01 0.86714606 0.85784662 948.00 5.43808626e-01 6.96400421e-01 8.83573068e-01 0.90782005 0.84318932 948.25 4.86013178e-01 7.13654089e-01 8.63429770e-01 0.97292207 0.81287292 948.50 4.71286038e-01 7.35054674e-01 8.73164305e-01 1.00066220 0.85217030 948.75 4.70891656e-01 7.27931202e-01 8.66961814e-01 0.99661027 0.84998273 949.00 4.44845362e-01 6.70662361e-01 8.04782827e-01 0.98513327 0.78499512 949.25 3.84897308e-01 6.68190254e-01 7.71118767e-01 1.04818868 0.77583789 949.50 2.46390199e-01 7.07580063e-01 7.49251410e-01 1.23571233 0.77362637 949.75 2.12169056e-01 7.64099515e-01 7.93009318e-01 1.29994766 0.83468905 950.00 2.21302526e-01 6.70274353e-01 7.05862958e-01 1.25189810 0.77885771 950.25 1.75270076e-01 6.02067189e-01 6.27060204e-01 1.28751180 0.72693041 950.50 1.40442975e-01 5.64839179e-01 5.82037393e-01 1.32709580 0.71512607 950.75 1.06211953e-01 6.01364015e-01 6.10671481e-01 1.39598078 0.74593033 951.00 1.84352299e-01 6.30125275e-01 6.56539133e-01 1.28617496 0.72025174 951.25 1.97371315e-01 6.37130499e-01 6.67001281e-01 1.27038991 0.69087720 951.50 1.89105632e-01 6.78002030e-01 7.03880453e-01 1.29879307 0.77627235 951.75 1.58564701e-01 6.99602799e-01 7.17347085e-01 1.34791232 0.78654198 952.00 1.49393894e-01 6.86202962e-01 7.02277040e-01 1.35643045 0.75213483 952.25 1.67253664e-01 6.98872669e-01 7.18607539e-01 1.33589515 0.75949043 952.50 5.30240116e-02 7.15777589e-01 7.17738882e-01 1.49685250 0.74039773 952.75 4.07807548e-02 6.80940942e-01 6.82161005e-01 1.51097895 0.80033025 953.00 1.13068721e-01 6.04450875e-01 6.14935278e-01 1.38587324 0.82484859 953.25 1.45498040e-01 5.62732999e-01 5.81238426e-01 1.31778123 0.80550433 953.50 1.28695713e-01 4.27199995e-01 4.46164120e-01 1.27818946 0.72186095 953.75 1.19347832e-01 4.23038859e-01 4.39551796e-01 1.29582259 0.69321283 954.00 5.45629016e-02 3.69204856e-01 3.73214865e-01 1.42407344 0.51646604 954.25 -1.13814461e-02 3.88601629e-01 3.88768264e-01 1.60007617 0.54294085 954.50 -1.35955746e-01 3.50049774e-01 3.75524712e-01 1.94125398 0.46185936 954.75 -2.06570278e-01 3.02633890e-01 3.66413088e-01 2.16973157 0.41445717 955.00 -2.45181277e-01 3.61881670e-01 4.37118064e-01 2.16627369 0.54630612 955.25 -3.01484600e-01 4.00202614e-01 5.01053985e-01 2.21642518 0.56236829 955.50 -3.49913408e-01 5.32242029e-01 6.36962299e-01 2.15237903 0.70379038 955.75 -3.14852340e-01 5.81472485e-01 6.61242956e-01 2.06707025 0.74479230 956.00 -3.38938665e-01 6.13898269e-01 7.01249244e-01 2.07525717 0.77405549 956.25 -3.00529433e-01 6.38853280e-01 7.06010944e-01 2.01050126 0.76828509 956.50 -2.93896434e-01 7.14460152e-01 7.72546712e-01 1.96105262 0.82192547 956.75 -2.56244668e-01 7.73139646e-01 8.14497540e-01 1.89083640 0.79618792 957.00 -2.68538034e-01 8.12363574e-01 8.55597599e-01 1.89005228 0.72661244 957.25 -3.27865363e-01 8.07062970e-01 8.71117865e-01 1.95667478 0.73250160 957.50 -2.96699716e-01 8.26484577e-01 8.78127256e-01 1.91545752 0.73684719 957.75 -2.42511239e-01 7.85328855e-01 8.21920380e-01 1.87030880 0.70176836 958.00 -1.74795393e-01 7.77631756e-01 7.97034866e-01 1.79190054 0.74564745 958.25 -1.78553217e-01 7.42425368e-01 7.63594577e-01 1.80681392 0.71905720 958.50 -1.96271659e-01 8.16202868e-01 8.39469884e-01 1.80678492 0.75899968 958.75 -7.74180291e-02 8.36481299e-01 8.40056257e-01 1.66308543 0.71819030 959.00 -2.07181663e-02 8.61396117e-01 8.61645236e-01 1.59484354 0.74696184 959.25 -4.31832042e-02 7.80309618e-01 7.81503608e-01 1.62608105 0.69574411 959.50 -4.69690412e-02 7.15754509e-01 7.17293948e-01 1.63632409 0.75793754 959.75 -7.46905244e-03 6.47535824e-01 6.47578898e-01 1.58233039 0.70263202 960.00 -5.68789855e-02 6.07449466e-01 6.10106607e-01 1.66415985 0.66328445 960.25 -3.04912304e-02 5.50259145e-01 5.51103295e-01 1.62615221 0.60755147 960.50 -6.15740574e-02 5.37038466e-01 5.40556823e-01 1.68495268 0.68042771 960.75 -7.93977891e-02 4.97476351e-01 5.03772497e-01 1.72906265 0.64844945 961.00 -9.94999901e-02 4.36088909e-01 4.47296081e-01 1.79512070 0.57425683 961.25 -1.81268620e-01 4.50003062e-01 4.85140256e-01 1.95372829 0.55705171 961.50 -2.47326531e-01 4.39644048e-01 5.04437609e-01 2.08323201 0.57997385 961.75 -3.19109147e-01 4.66631554e-01 5.65310229e-01 2.17060554 0.66105444 962.00 -3.45438923e-01 4.89988989e-01 5.99514186e-01 2.18486560 0.67495653 962.25 -4.22431403e-01 5.07308619e-01 6.60159319e-01 2.26515550 0.65746577 962.50 -4.26601110e-01 4.75412423e-01 6.38753065e-01 2.30213349 0.62446610 962.75 -4.36686236e-01 4.94162831e-01 6.59463246e-01 2.29452637 0.56881275 963.00 -5.05649089e-01 5.39316596e-01 7.39285730e-01 2.32398686 0.62045584 963.25 -5.92914152e-01 5.77026109e-01 8.27348972e-01 2.36977387 0.63962933 963.50 -5.84457996e-01 5.50037215e-01 8.02578400e-01 2.38652536 0.61664488 963.75 -4.24929686e-01 6.24143445e-01 7.55063095e-01 2.16853387 0.54175418 964.00 -3.72484439e-01 7.12374163e-01 8.03879098e-01 2.05257800 0.60288730 964.25 -3.01875729e-01 6.81021598e-01 7.44929105e-01 1.98803863 0.52477477 964.50 -3.04813170e-01 6.50324444e-01 7.18215115e-01 2.00909959 0.51459505 964.75 -1.66446216e-01 6.34373322e-01 6.55845908e-01 1.82739142 0.57160660 965.00 -1.40669127e-01 5.30207865e-01 5.48550986e-01 1.83013113 0.45743645 965.25 -1.66837749e-01 4.83645565e-01 5.11613005e-01 1.90297298 0.47017900 965.50 -1.43700184e-01 5.01684242e-01 5.21859006e-01 1.84976266 0.51419836 965.75 -1.50715257e-01 4.45845213e-01 4.70630473e-01 1.89678039 0.45824864 966.00 -1.52319971e-01 4.14493127e-01 4.41594753e-01 1.92296221 0.40118796 966.25 -2.90241032e-01 2.76161401e-01 4.00630722e-01 2.38104737 0.40156055 966.50 -3.63498948e-01 2.21212750e-01 4.25519172e-01 2.59489912 0.39803972 966.75 -3.33016758e-01 1.87025612e-01 3.81940756e-01 2.62987937 0.35752636 967.00 -3.59400474e-01 1.59172954e-01 3.93070896e-01 2.72467159 0.32439250 967.25 -4.08358619e-01 8.81520929e-02 4.17764950e-01 2.92898574 0.42146174 967.50 -4.52383630e-01 8.02578857e-02 4.59447796e-01 2.96600848 0.40432965 967.75 -4.61536527e-01 1.17994594e-01 4.76380825e-01 2.89129780 0.32780331 968.00 -6.94227666e-01 1.20382385e-01 7.04587802e-01 2.96989524 0.46027591 968.25 -6.93831364e-01 7.19327274e-02 6.97550198e-01 3.03828707 0.47841911 968.50 -6.89915310e-01 1.59533016e-01 7.08119989e-01 2.91435101 0.38632209 968.75 -9.44754980e-01 3.06448528e-01 9.93213307e-01 2.82793225 0.40232950 969.00 -8.39525053e-01 5.48242358e-01 1.00268240e+00 2.56308422 0.46072092 969.25 -7.84957063e-01 6.24606215e-01 1.00314033e+00 2.46946678 0.54588274 969.50 -9.13793698e-01 6.77265442e-01 1.13741259e+00 2.50377453 0.53772358 969.75 -8.77139917e-01 7.23070130e-01 1.13675188e+00 2.45217960 0.49068191 970.00 -5.99334627e-01 7.89401223e-01 9.91138884e-01 2.22017653 0.41184179 970.25 -4.51093230e-01 1.00669814e+00 1.10314380e+00 1.99206230 0.43519706 970.50 -5.28416436e-01 1.13451794e+00 1.25154100e+00 2.00668114 0.55542489 970.75 -8.13432969e-01 1.24780378e+00 1.48952592e+00 2.14850026 0.64114347 971.00 -6.21658024e-01 1.11601715e+00 1.27747915e+00 2.07902287 0.60550064 971.25 -4.78189197e-01 1.07567076e+00 1.17717139e+00 1.98910861 0.55116164 971.50 -5.52167978e-01 1.28344116e+00 1.39717954e+00 1.97708393 0.69023399 971.75 -7.99854367e-01 1.39614406e+00 1.60903239e+00 2.09105282 0.78790904 972.00 -6.90440666e-01 1.31433427e+00 1.48464908e+00 2.05449092 0.79607759 972.25 -6.28003020e-01 1.18128562e+00 1.33784286e+00 2.05942405 0.77250683 972.50 -8.29552468e-01 1.03264511e+00 1.32458039e+00 2.24756309 0.69498587 972.75 -8.03482742e-01 1.06503476e+00 1.33412277e+00 2.21711977 0.63204342 973.00 -7.40984231e-01 8.88319038e-01 1.15679226e+00 2.26601167 0.45855657 973.25 -7.90665949e-01 6.86580001e-01 1.04716032e+00 2.42653769 0.33507790 973.50 -9.06756427e-01 5.34384640e-01 1.05250851e+00 2.60905088 0.38837899 973.75 -1.09544440e+00 5.83938331e-01 1.24136312e+00 2.65184763 0.40954346 974.00 -8.89416727e-01 5.09373894e-01 1.02495067e+00 2.62148443 0.28624566 974.25 -6.59455147e-01 3.16244446e-01 7.31362866e-01 2.69443511 0.17216184 974.50 -5.83898727e-01 -1.03465488e-01 5.92994798e-01 -2.96621543 0.04341534 974.75 -6.01444257e-01 -2.70639798e-01 6.59530966e-01 -2.71875272 0.04257592 975.00 -4.87041830e-01 2.57745637e-01 5.51037710e-01 2.65485387 0.02272439 975.25 -4.78476893e-01 1.20811678e-01 4.93493261e-01 2.89426978 0.01809454 975.50 1.49883573e-01 2.73918192e-01 3.12243913e-01 1.07011791 0.01058377 975.75 4.80210591e-01 6.81766541e-01 8.33911164e-01 0.95714870 0.07315133 976.00 2.49628853e-01 6.19342260e-01 6.67756992e-01 1.18765930 0.04703081 976.25 2.36070358e-01 3.13215395e-01 3.92215627e-01 0.92493160 0.01507314 976.50 4.97833139e-01 -1.22975330e-01 5.12797003e-01 -0.24217311 0.02080903 976.75 1.16629059e+00 7.59453902e-03 1.16631531e+00 0.00651161 0.10864853 977.00 1.27920170e+00 2.25173172e-01 1.29886872e+00 0.17424132 0.15341961 977.25 5.45430429e-01 2.64459204e-01 6.06162539e-01 0.45146510 0.04412939 977.50 6.46538728e-02 3.04893979e-01 3.11673646e-01 1.36183806 0.01735192 977.75 -3.28037182e-02 1.95176434e-01 1.97913932e-01 1.73731217 0.00776973 978.00 -4.74011470e-01 1.77166985e-01 5.06038550e-01 2.78390870 0.07007907 978.25 -8.12336166e-01 -4.91722646e-02 8.13823051e-01 -3.08113451 0.19476502 978.50 -9.07001162e-01 -2.92859089e-01 9.53109413e-01 -2.82927287 0.29957760 978.75 -5.69102157e-01 -2.47240013e-01 6.20487622e-01 -2.73175457 0.18421956 979.00 -3.75202162e-01 -1.64730206e-01 4.09771525e-01 -2.72788712 0.12300701 979.25 -1.71194356e-01 -7.55139678e-02 1.87109238e-01 -2.72616390 0.02536006 979.50 -1.74410628e-01 -1.18655342e-01 2.10945864e-01 -2.54419602 0.02430105 979.75 -1.42072893e-01 -1.50389544e-01 2.06885771e-01 -2.32776550 0.04363291 980.00 -2.41524592e-01 -1.93816360e-01 3.09675491e-01 -2.46534712 0.15744233 980.25 -2.29850325e-01 -2.57374401e-01 3.45069202e-01 -2.29976293 0.18104705 980.50 -5.98441148e-02 -2.70042531e-01 2.76594083e-01 -1.78888175 0.10379893 980.75 -2.46565608e-01 -3.38900632e-01 4.19104089e-01 -2.19977096 0.16845062 981.00 -2.98231779e-01 -2.87393254e-01 4.14170347e-01 -2.37470000 0.13861363 981.25 -2.10386633e-01 -2.79582733e-01 3.49898613e-01 -2.21589695 0.06879988 981.50 -1.08872278e-01 -1.57015246e-01 1.91067947e-01 -2.17707001 0.02129458 981.75 1.29797148e-01 -3.19708595e-01 3.45052004e-01 -1.18514046 0.05075915 982.00 4.31202030e-01 -6.11438546e-01 7.48192680e-01 -0.95657194 0.19350729 982.25 6.74809825e-01 -8.42415630e-01 1.07936666e+00 -0.89542069 0.40103891 982.50 7.48676739e-01 -8.82148251e-01 1.15702308e+00 -0.86705910 0.49331525 982.75 6.59640236e-01 -1.08740697e+00 1.27184085e+00 -1.02552513 0.54613393 983.00 7.65894188e-01 -1.15145509e+00 1.38291096e+00 -0.98384215 0.54813033 983.25 7.65322443e-01 -8.66858982e-01 1.15635762e+00 -0.84752720 0.44333124 983.50 5.03690374e-01 -7.67349665e-01 9.17894058e-01 -0.98993326 0.37428391 983.75 4.76462906e-01 -8.33762106e-01 9.60300031e-01 -1.05162542 0.35044243 984.00 4.83451830e-01 -9.33938934e-01 1.05164994e+00 -1.09313003 0.38861563 984.25 6.17172127e-01 -8.31625654e-01 1.03561704e+00 -0.93235279 0.40279008 984.50 4.46380023e-01 -5.78982365e-01 7.31078453e-01 -0.91400679 0.22085807 984.75 3.06447731e-01 -3.84770796e-01 4.91893055e-01 -0.89822849 0.16291225 985.00 1.24759684e-01 -3.70924782e-01 3.91344059e-01 -1.24633533 0.10712131 985.25 2.14064981e-01 -1.02454999e-01 2.37320128e-01 -0.44639481 0.03540576 985.50 3.58248634e-01 -1.35460536e-01 3.83003447e-01 -0.36150213 0.09942801 985.75 3.15031761e-01 -1.68490496e-02 3.15482013e-01 -0.05343274 0.09888813 986.00 2.66469706e-01 -6.98758331e-02 2.75479103e-01 -0.25645390 0.07476471 986.25 2.56201204e-01 -1.63949828e-01 3.04168708e-01 -0.56926074 0.09701812 986.50 2.72217576e-01 -2.90379435e-01 3.98023397e-01 -0.81766914 0.16650567 986.75 1.17365004e-01 -1.34583525e-01 1.78570068e-01 -0.85363348 0.04241477 987.00 1.47788501e-01 -6.71885718e-02 1.62344527e-01 -0.42669467 0.02770917 987.25 2.60801936e-01 -6.78853875e-02 2.69492256e-01 -0.25464417 0.10465290 987.50 1.81561452e-01 -5.88657107e-02 1.90865746e-01 -0.31352554 0.06907007 987.75 1.41380898e-01 -6.86781360e-02 1.57179021e-01 -0.45219629 0.04607419 988.00 1.82071711e-01 5.87227196e-02 1.91307255e-01 0.31199192 0.06690594 988.25 2.18316682e-01 8.13132005e-02 2.32967830e-01 0.35653782 0.14197913 988.50 1.80497696e-01 1.40766054e-01 2.28898450e-01 0.66235000 0.15964805 988.75 2.80899786e-01 2.64856386e-01 3.86074598e-01 0.75600998 0.35053351 989.00 3.49210375e-01 3.55337396e-01 4.98209345e-01 0.79409433 0.44745302 989.25 4.50262814e-01 2.51998190e-01 5.15984195e-01 0.51023639 0.42186750 989.50 4.36539424e-01 1.27561628e-01 4.54795160e-01 0.28429571 0.32234475 989.75 4.61696331e-01 7.35210422e-02 4.67513471e-01 0.15791524 0.43249890 990.00 4.57046005e-01 9.90455280e-02 4.67654859e-01 0.21340813 0.39379947 990.25 4.77340242e-01 8.27634763e-02 4.84462073e-01 0.17167790 0.37194465 990.50 5.87426851e-01 8.51287568e-02 5.93563148e-01 0.14391616 0.49139835 990.75 5.74818746e-01 5.42702699e-02 5.77374967e-01 0.09413380 0.48667728 991.00 6.30286554e-01 -1.31446291e-01 6.43847239e-01 -0.20560308 0.47777356 991.25 6.05802979e-01 -1.79264186e-01 6.31769656e-01 -0.28770185 0.51281023 991.50 5.51946972e-01 -1.81953898e-01 5.81164934e-01 -0.31843938 0.50157307 991.75 5.31753709e-01 -2.83190489e-01 6.02460671e-01 -0.48935467 0.52935069 992.00 4.37859711e-01 -2.17958362e-01 4.89108346e-01 -0.46187105 0.36685105 992.25 3.95091164e-01 -2.43023562e-01 4.63850708e-01 -0.55145400 0.41274322 992.50 4.21225429e-01 -2.75169138e-01 5.03139063e-01 -0.57866257 0.43546643 992.75 4.32562251e-01 -2.95903561e-01 5.24088750e-01 -0.59995560 0.49812088 993.00 4.29312969e-01 -4.12239500e-01 5.95189912e-01 -0.76511288 0.60077456 993.25 4.66182374e-01 -3.25759761e-01 5.68722629e-01 -0.60990792 0.58857161 993.50 4.47677766e-01 -2.03852603e-01 4.91905749e-01 -0.42729876 0.47820350 993.75 3.67005282e-01 -1.98537618e-01 4.17264979e-01 -0.49588137 0.38187266 994.00 2.68446250e-01 -2.09090308e-01 3.40267757e-01 -0.66173628 0.39194236 994.25 2.51355282e-01 -1.76927773e-01 3.07380733e-01 -0.61333540 0.39535352 994.50 2.08076308e-01 -9.83756000e-02 2.30159746e-01 -0.44164050 0.27483417 994.75 1.78508413e-01 -4.16717957e-02 1.83307916e-01 -0.22933730 0.16157015 995.00 1.70485175e-01 3.66761757e-02 1.74385597e-01 0.21189873 0.10803597 995.25 1.39785396e-01 6.25511222e-02 1.53142416e-01 0.42075604 0.12157175 995.50 1.06959841e-01 1.80900596e-01 2.10155736e-01 1.03682581 0.16626411 995.75 6.53578796e-02 1.67383072e-01 1.79690693e-01 1.19853334 0.13127075 996.00 7.14149556e-03 1.34907797e-01 1.35096687e-01 1.51790957 0.09417146 996.25 3.55928284e-02 1.46744536e-01 1.50999366e-01 1.33284200 0.10512832 996.50 5.37572398e-02 1.60704820e-01 1.69457605e-01 1.24798787 0.11557515 996.75 6.50823609e-02 1.37995996e-01 1.52573290e-01 1.13010529 0.09788861 997.00 1.39969571e-01 1.30622852e-01 1.91451848e-01 0.75087020 0.15622043 997.25 1.39001868e-01 1.41597858e-01 1.98422460e-01 0.79464948 0.16721267 997.50 1.12310886e-01 1.59443812e-01 1.95028368e-01 0.95712904 0.23382689 997.75 7.94713249e-02 1.80196892e-01 1.96943168e-01 1.15543107 0.22903412 998.00 8.41419262e-02 1.45075900e-01 1.67710705e-01 1.04522334 0.27453932 998.25 8.75486601e-02 8.17808695e-02 1.19803500e-01 0.75134881 0.12524907 998.50 8.91096638e-02 3.43396142e-03 8.91758054e-02 0.03851729 0.09517596 998.75 6.50607791e-02 -2.22579719e-02 6.87627973e-02 -0.32962904 0.05784119 999.00 -2.10649466e-02 -3.95109916e-02 4.47755562e-02 -2.06060424 0.02588804 999.25 -1.47033704e-02 -1.86079074e-02 2.37158875e-02 -2.23951324 0.00633388 999.50 -7.68996152e-03 6.40375824e-04 7.71657886e-03 3.05851009 0.00065031 999.75 2.34872669e-02 2.34158563e-02 3.31655549e-02 0.78387565 0.01281236 1000.00 3.32571428e-02 0.00000000e+00 3.32571428e-02 0.00000000 0.02696248