========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : BOTTOM Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0043 Injection acquisition : SIG0044 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -1.10193224e-01 0.00000000e+00 1.10193224e-01 3.14159265 0.02905170 0.25 -1.16702372e-01 -1.31483378e-02 1.17440719e-01 -3.02940021 0.03831785 0.50 -1.38405091e-01 -1.78856020e-02 1.39555953e-01 -3.01307839 0.35818246 0.75 -1.25370234e-01 -1.32297988e-02 1.26066345e-01 -3.03645592 0.32218164 1.00 -1.21977305e-01 -1.41447019e-02 1.22794688e-01 -3.02614653 0.24811808 1.25 -1.14473493e-01 -2.15817425e-03 1.14493835e-01 -3.12274184 0.22443906 1.50 -1.23067437e-01 5.78897927e-03 1.23203516e-01 3.09458822 0.24144301 1.75 -1.36679927e-01 -2.02911008e-02 1.38177897e-01 -2.99421203 0.26963471 2.00 -1.43690446e-01 -3.36422569e-02 1.47576237e-01 -2.91160524 0.28427068 2.25 -1.45341441e-01 -1.19029857e-03 1.45346315e-01 -3.13340317 0.25389369 2.50 -1.41692853e-01 1.51649269e-04 1.41692934e-01 3.14052239 0.22063850 2.75 -1.26622998e-01 -4.16113193e-02 1.33284978e-01 -2.82408673 0.19472206 3.00 -1.33167328e-01 -4.96001259e-02 1.42104573e-01 -2.78504658 0.17994364 3.25 -1.29517859e-01 -2.30794995e-02 1.31558121e-01 -2.96524813 0.19470104 3.50 -1.27382583e-01 -2.09645354e-02 1.29096221e-01 -2.97847562 0.18357153 3.75 -1.23046302e-01 -2.80499194e-02 1.26202973e-01 -2.91746044 0.15808898 4.00 -1.23742088e-01 -3.42402989e-02 1.28391987e-01 -2.87164017 0.14491081 4.25 -1.21383970e-01 -2.49750998e-02 1.23926687e-01 -2.93867166 0.15449121 4.50 -1.32840210e-01 -2.32470133e-02 1.34858982e-01 -2.96834716 0.17030717 4.75 -1.24291322e-01 -3.79836011e-02 1.29965713e-01 -2.84500492 0.12146455 5.00 -1.30047735e-01 -4.83861542e-02 1.38757462e-01 -2.78539799 0.13465228 5.25 -1.20825887e-01 -2.40079485e-02 1.23187972e-01 -2.94544864 0.10721184 5.50 -1.10560181e-01 -3.12226346e-02 1.14884318e-01 -2.86635614 0.08160471 5.75 -8.75575456e-02 -2.91339806e-02 9.22773679e-02 -2.82037534 0.05498777 6.00 -8.62614630e-02 -3.10179628e-02 9.16687188e-02 -2.79640826 0.05278422 6.25 -9.08516582e-02 -7.20581889e-02 1.15958641e-01 -2.47104795 0.07379533 6.50 -9.41619900e-02 -5.59213498e-02 1.09515651e-01 -2.60568195 0.06633854 6.75 -8.86037648e-02 1.58860658e-02 9.00166331e-02 2.96418427 0.04493877 7.00 -9.89855165e-02 -1.02239827e-02 9.95121214e-02 -3.03866996 0.05139532 7.25 -1.53198317e-01 -4.22591675e-02 1.58919985e-01 -2.87243995 0.10730681 7.50 -1.54614811e-01 -3.03632429e-02 1.57567974e-01 -2.94768036 0.10591575 7.75 -1.40696844e-01 -3.97455571e-02 1.46202980e-01 -2.86627578 0.09275339 8.00 -1.26220600e-01 -3.36995994e-02 1.30641888e-01 -2.88068870 0.07692141 8.25 -1.66246083e-01 -1.19122708e-02 1.66672320e-01 -3.07006047 0.12267868 8.50 -1.47977897e-01 -3.70823571e-02 1.52553463e-01 -2.89605511 0.09450812 8.75 -1.35824908e-01 -7.89974956e-02 1.57127368e-01 -2.61480293 0.09286900 9.00 -1.12660486e-01 -6.26535046e-02 1.28910227e-01 -2.63405781 0.05955606 9.25 -7.70267613e-02 -5.60983938e-02 9.52898302e-02 -2.51212647 0.02877878 9.50 -1.13644119e-01 -5.40038464e-02 1.25822896e-01 -2.69797999 0.05416326 9.75 -1.39118611e-01 -7.49862992e-02 1.58040922e-01 -2.64722633 0.08554053 10.00 -1.15994755e-01 -6.88607349e-02 1.34894714e-01 -2.60585249 0.05836350 10.25 -1.02655411e-01 -3.69836953e-02 1.09114285e-01 -2.79579781 0.03772080 10.50 -1.38708044e-01 -6.35013469e-02 1.52552753e-01 -2.71226642 0.07021034 10.75 -1.46580678e-01 -9.58942355e-02 1.75161638e-01 -2.56226503 0.08442717 11.00 -1.20950049e-01 -8.16857422e-02 1.45950248e-01 -2.54759050 0.06113787 11.25 -9.90060042e-02 -7.30882237e-02 1.23061275e-01 -2.50567340 0.03908417 11.50 -1.25519637e-01 -6.59770514e-02 1.41803211e-01 -2.65765088 0.05435400 11.75 -1.35117067e-01 -6.48009628e-02 1.49852550e-01 -2.69440494 0.06363365 12.00 -1.50953919e-01 -6.39100489e-02 1.63925532e-01 -2.74109958 0.06607457 12.25 -1.57439504e-01 -6.69673018e-02 1.71090084e-01 -2.73942339 0.06371515 12.50 -1.01402569e-01 -1.01554824e-01 1.43512589e-01 -2.35544431 0.04799192 12.75 -7.55290041e-02 -1.06814176e-01 1.30820100e-01 -2.18627589 0.03700007 13.00 -1.37724744e-01 -9.19484007e-02 1.65597746e-01 -2.55292729 0.05501357 13.25 -1.33943934e-01 -7.39201379e-02 1.52987465e-01 -2.63731202 0.04444890 13.50 -1.15635629e-01 -4.78344033e-02 1.25138838e-01 -2.74936196 0.02895541 13.75 -1.31557241e-01 -4.79863228e-02 1.40035691e-01 -2.79183293 0.03341046 14.00 -1.03161855e-01 -6.68426180e-02 1.22923976e-01 -2.56666746 0.02966128 14.25 -1.07750988e-01 -4.97945527e-02 1.18700349e-01 -2.70870047 0.02573144 14.50 -7.77371653e-02 -1.10704706e-01 1.35272314e-01 -2.18299921 0.03335647 14.75 -9.39133901e-02 -1.14125910e-01 1.47798674e-01 -2.25934126 0.03946887 15.00 -1.35954596e-01 -4.42001225e-02 1.42959096e-01 -2.82726177 0.03265900 15.25 -1.39335709e-01 -2.70678577e-02 1.41940512e-01 -2.94971889 0.03185235 15.50 -1.49564278e-01 -5.66002544e-02 1.59915797e-01 -2.77981449 0.04088064 15.75 -1.39679053e-01 -8.02387791e-02 1.61085380e-01 -2.62017102 0.04090096 16.00 -1.23319402e-01 -1.34713617e-01 1.82634700e-01 -2.31206519 0.04550019 16.25 -1.09722513e-01 -1.10717560e-01 1.55876259e-01 -2.35168061 0.03187925 16.50 -1.04249443e-01 -4.64644517e-02 1.14135409e-01 -2.72231656 0.01935164 16.75 -1.12493275e-01 -4.09672680e-02 1.19720733e-01 -2.79234577 0.01965151 17.00 -5.59955489e-02 -1.00959920e-01 1.15448720e-01 -2.07718841 0.01974708 17.25 -8.31060405e-02 -1.00191366e-01 1.30172669e-01 -2.26325209 0.02296551 17.50 -5.35481262e-02 -7.36850283e-02 9.10872396e-02 -2.19922872 0.01000174 17.75 -6.76940424e-02 -8.27934546e-02 1.06945030e-01 -2.25619253 0.01425841 18.00 -5.49881578e-02 -1.09333337e-01 1.22382499e-01 -2.03679353 0.01735394 18.25 -9.73616561e-02 -1.08271419e-01 1.45609039e-01 -2.30318967 0.02444675 18.50 -1.13161762e-01 -1.02717183e-01 1.52828021e-01 -2.40453844 0.02344730 18.75 -7.37077884e-02 -1.36765093e-01 1.55362572e-01 -2.06510632 0.02660087 19.00 -2.91539450e-02 -1.49830829e-01 1.52640852e-01 -1.76297407 0.02603560 19.25 -4.68931230e-02 -1.07876478e-01 1.17627801e-01 -1.98084809 0.01580806 19.50 -9.30733653e-02 -6.74871302e-02 1.14965926e-01 -2.51422150 0.01340659 19.75 -9.53764256e-02 -1.17274511e-01 1.51162077e-01 -2.25357952 0.02420171 20.00 -7.32409129e-02 -1.47434588e-01 1.64624388e-01 -2.03185569 0.02578212 20.25 -1.31426930e-01 -1.32942859e-01 1.86940743e-01 -2.35046043 0.03496411 20.50 -1.09165205e-01 -7.59869066e-02 1.33007714e-01 -2.53350740 0.01691326 20.75 -2.86044050e-02 -6.46568274e-02 7.07016076e-02 -1.98731505 0.00451218 21.00 6.38304885e-02 -6.04581273e-02 8.79176684e-02 -0.75827151 0.00635616 21.25 -5.98086957e-02 -8.85950665e-02 1.06893245e-01 -2.16460047 0.00951322 21.50 -1.32078761e-01 -1.83763378e-02 1.33350999e-01 -3.00334846 0.01873961 21.75 -8.15528081e-02 -5.33055655e-02 9.74286602e-02 -2.56266807 0.00838687 22.00 -1.29415793e-02 -5.70686226e-02 5.85176226e-02 -1.79379697 0.00254049 22.25 -8.87808507e-02 -8.98787300e-02 1.26333786e-01 -2.35004948 0.01350782 22.50 -8.22217235e-02 -6.49199204e-02 1.04761672e-01 -2.47324305 0.00926569 22.75 -8.23688844e-02 -1.22353929e-01 1.47496160e-01 -2.16330961 0.01653918 23.00 -5.51595031e-02 -1.83607746e-01 1.91714306e-01 -1.86263872 0.02751057 23.25 -9.61542307e-02 -1.41588601e-01 1.71151886e-01 -2.16736413 0.02280175 23.50 -1.37071627e-01 -3.34901074e-02 1.41103573e-01 -2.90196169 0.01425051 23.75 -6.92053131e-02 -1.06497549e-01 1.27008281e-01 -2.14705210 0.01126606 24.00 -5.41309318e-02 -1.73629695e-01 1.81872012e-01 -1.87300761 0.02210054 24.25 7.11895980e-02 -7.03880864e-02 1.00112145e-01 -0.77973694 0.00629805 24.50 8.60859408e-02 -6.97935838e-02 1.10823885e-01 -0.68125738 0.00837755 24.75 -2.04459442e-02 -1.36564480e-01 1.38086545e-01 -1.71940892 0.01371624 25.00 -4.27840656e-02 -1.09316437e-01 1.17390628e-01 -1.94384806 0.00950970 25.25 -1.68946450e-02 -1.76566980e-01 1.77373412e-01 -1.66618997 0.02146589 25.50 -1.41546451e-02 -1.98464652e-01 1.98968772e-01 -1.64199650 0.02520119 25.75 -1.64365883e-01 -1.04468042e-01 1.94755527e-01 -2.57541978 0.02272183 26.00 -6.15230990e-02 -9.64165760e-02 1.14373283e-01 -2.13875811 0.00791199 26.25 -1.13386885e-01 -1.57032461e-01 1.93689905e-01 -2.19617486 0.02226928 26.50 -1.81107525e-01 -1.50138357e-01 2.35247661e-01 -2.44941649 0.03048775 26.75 -1.87350398e-01 -2.09631034e-01 2.81150035e-01 -2.30012818 0.04955208 27.00 -2.01136440e-01 -1.85283743e-01 2.73470168e-01 -2.39719600 0.04425841 27.25 2.75870316e-04 -1.25280574e-01 1.25280878e-01 -1.56859431 0.00956701 27.50 -1.77183587e-02 -1.70643617e-01 1.71561022e-01 -1.67425811 0.01969593 27.75 -5.09927673e-02 -1.47388921e-01 1.55960752e-01 -1.90388022 0.01609030 28.00 -9.82365167e-02 -1.58544146e-01 1.86511821e-01 -2.12551475 0.02098914 28.25 -9.73926991e-02 -8.46385856e-02 1.29031113e-01 -2.42614568 0.00978882 28.50 -1.04899045e-01 -1.15619922e-01 1.56114625e-01 -2.30761616 0.01387814 28.75 -2.51706807e-01 -1.19077553e-01 2.78452474e-01 -2.69971172 0.04508987 29.00 -1.74386252e-01 -1.07704926e-01 2.04965646e-01 -2.58831589 0.02386209 29.25 -1.09376237e-01 2.44996822e-02 1.12086555e-01 2.92123541 0.00787360 29.50 -1.49407777e-01 -3.95081268e-02 1.54543120e-01 -2.88307817 0.01427439 29.75 -2.13436082e-01 -2.43638336e-02 2.14822153e-01 -3.02793413 0.02450298 30.00 -1.98714344e-01 -4.17948499e-02 2.03062059e-01 -2.93428798 0.02035864 30.25 -1.36431585e-01 -1.41700650e-01 1.96704478e-01 -2.33725230 0.01392875 30.50 -1.35345255e-01 -1.04915788e-01 1.71247367e-01 -2.48217543 0.01204307 30.75 -3.65253977e-01 4.01782312e-02 3.67457151e-01 3.03203233 0.06303918 31.00 -2.35464471e-01 -1.09339763e-01 2.59612597e-01 -2.70686314 0.03137442 31.25 -1.68167182e-01 -1.36037291e-01 2.16301516e-01 -2.46142374 0.02263734 31.50 -1.35639027e-01 -1.00435657e-01 1.68775789e-01 -2.50422333 0.01355844 31.75 -2.36863027e-01 1.82530223e-02 2.37565288e-01 3.06468315 0.02640644 32.00 -2.39190661e-01 -2.77268440e-02 2.40792338e-01 -3.02618830 0.02392369 32.25 -4.09026767e-01 -8.03189677e-02 4.16838138e-01 -2.94769371 0.05930541 32.50 -1.96896084e-01 -2.43471910e-01 3.13123999e-01 -2.25082055 0.02520756 32.75 6.13554570e-02 -3.62213224e-01 3.67372987e-01 -1.40299867 0.02803271 33.00 5.82090876e-03 -3.87070646e-01 3.87114412e-01 -1.55575910 0.04527246 33.25 -4.05338942e-02 -3.55740186e-01 3.58042003e-01 -1.68424944 0.03815885 33.50 -1.71715923e-01 -1.05796107e-01 2.01690789e-01 -2.58941082 0.01236403 33.75 -1.66114460e-01 -5.90141870e-02 1.76285814e-01 -2.80023763 0.00805349 34.00 1.42200598e-02 -1.62248132e-01 1.62870091e-01 -1.48337580 0.00808783 34.25 -2.90775650e-02 -1.28393509e-01 1.31644969e-01 -1.79351162 0.00559591 34.50 -9.62782850e-02 -2.56560686e-01 2.74030826e-01 -1.92979944 0.02631338 34.75 -1.33550825e-01 -2.85172429e-01 3.14895439e-01 -2.00877705 0.03414328 35.00 -1.83237835e-01 -1.68893481e-01 2.49200947e-01 -2.39690779 0.02442086 35.25 -2.97682847e-01 -1.61936037e-01 3.38878087e-01 -2.64337653 0.04231255 35.50 -2.15528148e-01 -1.03063633e-01 2.38902689e-01 -2.69554392 0.02235678 35.75 -1.63702152e-01 -1.26172454e-01 2.06683049e-01 -2.48494702 0.01500434 36.00 -2.99613349e-02 -4.08349086e-01 4.09446770e-01 -1.64403695 0.06101989 36.25 2.45448677e-01 -9.88543279e-01 1.01855921e+00 -1.32742461 0.23042984 36.50 5.04796960e-02 -1.64239801e+00 1.64317358e+00 -1.54007064 0.43455295 36.75 -3.27228038e-02 -8.98425429e-01 8.99021153e-01 -1.60720263 0.18618039 37.00 1.60178082e-02 -8.98900236e-02 9.13060049e-02 -1.39445385 0.00291763 37.25 6.48377792e-02 -1.69987191e-01 1.81932907e-01 -1.20640258 0.01161576 37.50 -1.24191411e-01 -3.59935010e-01 3.80758083e-01 -1.90304422 0.04580865 37.75 -1.57710764e-01 -2.76124438e-01 3.17989607e-01 -2.08973867 0.03647342 38.00 -8.82981885e-02 -2.17305446e-02 9.09328690e-02 -2.90028408 0.00347270 38.25 -8.76460728e-02 -9.31342136e-02 1.27889858e-01 -2.32584574 0.00659494 38.50 6.60703900e-02 -1.73321068e-01 1.85487167e-01 -1.20659914 0.01448386 38.75 5.93523451e-02 -1.82096819e-01 1.91525331e-01 -1.25571591 0.01516725 39.00 -1.11677988e-02 -2.66160011e-01 2.66394202e-01 -1.61273069 0.03074831 39.25 -3.32370353e-02 -3.22727594e-01 3.24434586e-01 -1.67342241 0.04137129 39.50 -1.16288960e-01 -2.42341503e-02 1.18787273e-01 -2.93613724 0.00444441 39.75 -5.00291949e-02 -9.69967447e-02 1.09138851e-01 -2.04698984 0.00420329 40.00 1.89610961e-02 -5.10231706e-02 5.44324086e-02 -1.21499455 0.00116268 40.25 6.10964166e-02 -6.17133403e-02 8.68407076e-02 -0.79042153 0.00309790 40.50 9.11127984e-02 -1.50363273e-01 1.75814265e-01 -1.02601247 0.01284327 40.75 1.00263192e-01 -1.34051723e-01 1.67399439e-01 -0.92861231 0.01178379 41.00 1.73412252e-02 -1.96393236e-01 1.97157351e-01 -1.48272625 0.01866595 41.25 1.21807385e-02 -1.00505424e-01 1.01240855e-01 -1.45018969 0.00392101 41.50 1.74407660e-01 -1.78827949e-01 2.49794850e-01 -0.79791122 0.02142420 41.75 -1.19387373e-01 -2.23406835e-01 2.53306058e-01 -2.06157942 0.02464159 42.00 -2.71961152e-01 -9.91227717e-02 2.89461901e-01 -2.79208203 0.02853492 42.25 -2.02879472e-01 -1.33943451e-01 2.43106825e-01 -2.55807203 0.02173552 42.50 -5.94402557e-01 -1.32295478e-01 6.08947037e-01 -2.92259344 0.14848696 42.75 -8.19442038e-01 3.42532240e-02 8.20157629e-01 3.09981631 0.25917328 43.00 -9.87528364e-01 1.26484003e-01 9.95595537e-01 3.01420484 0.36402141 43.25 -8.63961573e-01 -1.59184277e-02 8.64108208e-01 -3.12316981 0.23206090 43.50 -9.01748946e-01 -4.81705014e-03 9.01761812e-01 -3.13625081 0.20820588 43.75 -6.78436818e-01 1.70741398e-01 6.99592125e-01 2.89504395 0.05373707 44.00 -5.37194273e-01 2.18154838e-01 5.79801018e-01 2.75583835 0.01867487 44.25 4.68422967e-01 3.13854247e-01 5.63847998e-01 0.59032275 0.03185851 44.50 6.79567190e-01 1.59212845e-01 6.97968692e-01 0.23013489 0.07563432 44.75 3.29291760e-01 2.84063037e-02 3.30514722e-01 0.08605181 0.02538301 45.00 3.05108353e-01 -9.96154172e-02 3.20958469e-01 -0.31558071 0.02869826 45.25 3.53338177e-01 -6.70377354e-04 3.53338813e-01 -0.00189727 0.03024915 45.50 3.85143838e-01 4.77693961e-02 3.88094951e-01 0.12339982 0.04115268 45.75 4.17232635e-01 -1.26911351e-01 4.36107284e-01 -0.29528181 0.05232072 46.00 2.38107629e-01 6.07392763e-02 2.45732583e-01 0.24976507 0.02024414 46.25 -7.80215699e-02 3.83371990e-02 8.69316180e-02 2.68487553 0.00346520 46.50 -6.06547535e-02 3.43402662e-02 6.97011693e-02 2.62642761 0.00225262 46.75 1.18514892e-02 -1.06938352e-02 1.59629542e-02 -0.73409537 0.00007472 47.00 -3.55486856e-02 -1.16617909e-01 1.21915732e-01 -1.86667878 0.00376211 47.25 7.80479600e-02 -1.25173432e-01 1.47512278e-01 -1.01326302 0.00513146 47.50 2.41544422e-02 -1.40289060e-01 1.42353284e-01 -1.40029182 0.00439590 47.75 5.98535144e-02 -2.77476947e-01 2.83858943e-01 -1.35834521 0.02070126 48.00 9.30535579e-02 -2.40074546e-01 2.57477673e-01 -1.20102269 0.01446099 48.25 -6.57482723e-02 -1.18036721e-02 6.67994161e-02 -2.96395670 0.00097300 48.50 -1.02560452e-01 -1.44784518e-02 1.03577371e-01 -3.00134946 0.00197922 48.75 -2.48332061e-01 -2.62284093e-01 3.61194903e-01 -2.32887737 0.01864889 49.00 -1.66231502e-01 -2.07189743e-01 2.65632268e-01 -2.24694745 0.00875997 49.25 -2.36395601e-01 -2.36884603e-01 3.34659821e-01 -2.35516127 0.01229608 49.50 -5.40033453e-02 -5.44728454e-01 5.47398803e-01 -1.66961154 0.01153438 49.75 -1.19964560e+00 -1.55925816e+00 1.96734226e+00 -2.22657908 0.02247400 50.00 -2.88665918e+00 -1.86257910e+00 3.43540422e+00 -2.56857310 0.03307998 50.25 -1.40934692e+00 8.17956404e-02 1.41171855e+00 3.08361971 0.01198603 50.50 -2.64139047e-01 6.45330103e-01 6.97295044e-01 1.95930136 0.01134973 50.75 -2.75849411e-01 2.07611187e-01 3.45246727e-01 2.49641361 0.00750607 51.00 -3.32777458e-01 -5.66000677e-02 3.37556520e-01 -2.97312101 0.00939969 51.25 -4.03631985e-01 -1.79899808e-01 4.41908045e-01 -2.72231823 0.02842391 51.50 -1.31059601e-01 -1.39646364e-01 1.91514297e-01 -2.32448523 0.00463453 51.75 1.11251454e-01 2.76148904e-02 1.14627519e-01 0.24330313 0.00145228 52.00 4.48611501e-02 6.63015488e-02 8.00525962e-02 0.97593254 0.00082580 52.25 1.50134051e-01 2.14389483e-01 2.61730937e-01 0.95987814 0.01212688 52.50 -1.02081689e-01 6.28018601e-02 1.19853014e-01 2.59006302 0.00252740 52.75 -1.44028988e-01 -2.49810422e-02 1.46179348e-01 -2.96985662 0.00464747 53.00 -2.71836602e-01 -9.40529359e-02 2.87647515e-01 -2.80849405 0.02456535 53.25 -4.62040776e-01 -7.24070760e-02 4.67679872e-01 -2.98614550 0.08583488 53.50 -5.82761559e-01 -1.44689793e-01 6.00454970e-01 -2.89823063 0.12283351 53.75 -5.61026624e-01 3.16006148e-03 5.61035523e-01 3.13596007 0.12047609 54.00 -3.58737682e-01 -1.22504929e-01 3.79078069e-01 -2.81252015 0.04131342 54.25 -3.29723798e-01 -7.77108677e-02 3.38757674e-01 -2.91013189 0.03212779 54.50 -4.10956488e-01 -6.45253607e-01 7.65008139e-01 -2.13790111 0.11056134 54.75 -7.63479836e-01 -5.57889443e-01 9.45590869e-01 -2.51054582 0.11927872 55.00 -5.31469796e-01 3.62305495e-01 6.43214906e-01 2.54325118 0.05777497 55.25 -2.72015774e-01 4.83645707e-01 5.54892558e-01 2.08313091 0.05034372 55.50 -4.30765956e-02 2.60536797e-01 2.64073883e-01 1.73465183 0.01631466 55.75 -7.79282423e-02 1.45422903e-01 1.64986762e-01 2.06272900 0.00785294 56.00 -3.84410452e-01 -1.27089083e-01 4.04874092e-01 -2.82229711 0.05901873 56.25 -5.43498488e-01 -6.88078715e-02 5.47836772e-01 -3.01566084 0.10860912 56.50 -7.47418169e-01 1.96428489e-02 7.47676241e-01 3.11531777 0.15479218 56.75 -9.59928481e-01 6.28195980e-02 9.61981803e-01 3.07624388 0.26357285 57.00 -1.33017969e+00 -1.61585112e-02 1.33027783e+00 -3.12944564 0.43083495 57.25 -1.84538406e+00 1.54840751e-01 1.85186878e+00 3.05788168 0.54221793 57.50 -2.53364126e+00 1.39553478e+00 2.89255171e+00 2.63813388 0.69225582 57.75 -2.78345822e+00 2.34775561e+00 3.64137282e+00 2.44090349 0.67081792 58.00 -1.56324665e+00 3.77328504e+00 4.08428942e+00 1.96356345 0.51937244 58.25 5.01846751e-01 2.76620633e+00 2.81136046e+00 1.39132773 0.36541104 58.50 1.72645506e+00 1.21686502e+00 2.11220443e+00 0.61396320 0.58268514 58.75 1.40973528e+00 8.39771845e-01 1.64090534e+00 0.53724783 0.58751548 59.00 9.79406897e-01 4.60897372e-01 1.08243441e+00 0.43984259 0.56042644 59.25 9.63732347e-01 5.07852459e-01 1.08935493e+00 0.48498556 0.58254834 59.50 1.22314551e+00 5.34910824e-01 1.33499608e+00 0.41226267 0.71534434 59.75 1.09128996e+00 2.45845985e-01 1.11863936e+00 0.22158109 0.60194230 60.00 1.08313366e+00 -8.16607884e-02 1.08620763e+00 -0.07525072 0.64276566 60.25 1.08715001e+00 -1.87044484e-01 1.10312320e+00 -0.17038219 0.61484877 60.50 9.98909639e-01 -1.33221202e-01 1.00775411e+00 -0.13258424 0.51751669 60.75 8.97387850e-01 -2.69323251e-01 9.36931143e-01 -0.29156607 0.43791647 61.00 7.82810913e-01 -5.70212331e-01 9.68470458e-01 -0.62954392 0.61437094 61.25 7.76409192e-01 -5.09251449e-01 9.28519397e-01 -0.58051587 0.51185852 61.50 8.66049604e-01 -5.11355256e-01 1.00574655e+00 -0.53336465 0.54689925 61.75 7.75179280e-01 -5.84627696e-01 9.70923508e-01 -0.64617340 0.53071279 62.00 8.66968548e-01 -6.63631053e-01 1.09180614e+00 -0.65332326 0.63175297 62.25 9.06951204e-01 -8.09758360e-01 1.21584090e+00 -0.72884276 0.69607757 62.50 8.81070329e-01 -9.48644021e-01 1.29468545e+00 -0.82231267 0.77418553 62.75 1.00820720e+00 -9.82527539e-01 1.40777914e+00 -0.77249929 0.69409258 63.00 1.23393769e+00 -9.36720438e-01 1.54920864e+00 -0.64931942 0.78943099 63.25 1.49289153e+00 -1.31325557e+00 1.98830714e+00 -0.72147023 0.80013112 63.50 1.70027977e+00 -1.66046778e+00 2.37657412e+00 -0.77355255 0.85632144 63.75 1.60582834e+00 -2.32998540e+00 2.82975558e+00 -0.96735482 0.80253223 64.00 1.67547960e+00 -3.28390185e+00 3.68663034e+00 -1.09901411 0.84979022 64.25 -5.51835567e-02 -4.17219992e+00 4.17256485e+00 -1.58402204 0.75306700 64.50 -1.69143079e+00 -4.05933220e+00 4.39762618e+00 -1.96559634 0.81522094 64.75 -2.61852556e+00 -2.57147839e+00 3.67003777e+00 -2.36525920 0.84230015 65.00 -2.63081362e+00 -1.78726973e+00 3.18048949e+00 -2.54485371 0.87093442 65.25 -1.98252653e+00 -1.14190645e+00 2.28787276e+00 -2.61901809 0.82461051 65.50 -1.65203399e+00 -9.40381067e-01 1.90092947e+00 -2.62410835 0.85403664 65.75 -1.26120368e+00 -8.22980493e-01 1.50596534e+00 -2.56343689 0.81246826 66.00 -1.14721065e+00 -7.49113917e-01 1.37013282e+00 -2.56312031 0.82238949 66.25 -9.53094519e-01 -7.81758197e-01 1.23269422e+00 -2.45463656 0.81239594 66.50 -8.49726167e-01 -7.67950044e-01 1.14533045e+00 -2.40670310 0.80108084 66.75 -7.01275317e-01 -7.47171101e-01 1.02472031e+00 -2.32451887 0.73181415 67.00 -6.46408418e-01 -7.94641671e-01 1.02435308e+00 -2.25369027 0.80255039 67.25 -5.37159708e-01 -6.41255633e-01 8.36510214e-01 -2.26808767 0.71887429 67.50 -4.89620061e-01 -6.69981688e-01 8.29821225e-01 -2.20189328 0.72968755 67.75 -4.04655655e-01 -6.76804007e-01 7.88549215e-01 -2.10966434 0.66584090 68.00 -3.21542239e-01 -6.82337448e-01 7.54303522e-01 -2.01116942 0.59304457 68.25 -1.12315973e-01 -6.39252701e-01 6.49044601e-01 -1.74472001 0.40874624 68.50 -6.55790809e-02 -6.55953450e-01 6.59223441e-01 -1.67044043 0.36658740 68.75 3.09585007e-01 -6.82931302e-01 7.49825339e-01 -1.14518663 0.35329635 69.00 4.81760673e-01 -6.80334574e-01 8.33635699e-01 -0.95463935 0.32592424 69.25 1.26356376e-01 -9.27406265e-01 9.35974527e-01 -1.43538306 0.18936833 69.50 -2.86989184e-01 -1.12546521e+00 1.16147955e+00 -1.82047160 0.26970232 69.75 3.00632958e-01 -1.33092105e+00 1.36445265e+00 -1.34864122 0.48689930 70.00 3.58728968e-01 -1.29827965e+00 1.34692855e+00 -1.30121168 0.38184062 70.25 4.98440679e-01 -1.44531912e+00 1.52885266e+00 -1.23870299 0.27688061 70.50 7.23213482e-01 -1.68538075e+00 1.83399728e+00 -1.16544976 0.32228625 70.75 7.43694889e-01 -1.99898618e+00 2.13284501e+00 -1.21462673 0.41295225 71.00 5.99921250e-01 -1.82078032e+00 1.91706716e+00 -1.25251255 0.25268243 71.25 8.19843253e-01 -5.25684887e-01 9.73903260e-01 -0.57016524 0.05277834 71.50 -5.47568030e-01 3.60768408e-01 6.55732104e-01 2.55901704 0.03662067 71.75 -2.16161393e+00 9.09769972e-02 2.16352759e+00 3.09952995 0.44816616 72.00 -2.10838305e+00 -4.57125974e-01 2.15736952e+00 -2.92808374 0.43154286 72.25 -2.00237570e+00 -1.05921529e+00 2.26526941e+00 -2.65503127 0.52626236 72.50 -1.95233776e+00 -9.55341485e-01 2.17354551e+00 -2.68651575 0.53492151 72.75 -2.41049362e+00 -1.15847792e+00 2.67442528e+00 -2.69358694 0.75688313 73.00 -2.30770135e+00 -9.93974895e-01 2.51266226e+00 -2.73488646 0.74956719 73.25 -2.31610664e+00 -1.00798108e+00 2.52594058e+00 -2.73111017 0.81239468 73.50 -2.10808264e+00 -1.00604764e+00 2.33583909e+00 -2.69632357 0.71930269 73.75 -2.05530734e+00 -7.54190998e-01 2.18931321e+00 -2.78989986 0.68088253 74.00 -1.98070557e+00 -7.88577547e-01 2.13191207e+00 -2.76269972 0.66677796 74.25 -1.93501522e+00 -8.57495482e-01 2.11650240e+00 -2.72445258 0.69795189 74.50 -2.00779657e+00 -7.58148862e-01 2.14616793e+00 -2.78054236 0.71166175 74.75 -2.03170029e+00 -6.98875827e-01 2.14854218e+00 -2.81028581 0.76608265 75.00 -2.13983308e+00 -8.02109208e-01 2.28522752e+00 -2.78295646 0.69103621 75.25 -2.37897718e+00 -8.11524879e-01 2.51358410e+00 -2.81284746 0.71588122 75.50 -1.93729629e+00 -9.97125019e-01 2.17884722e+00 -2.66625488 0.67078733 75.75 -1.88796622e+00 -1.05235944e+00 2.16145248e+00 -2.63308296 0.75722820 76.00 -1.96052058e+00 -1.01667284e+00 2.20845299e+00 -2.66319737 0.73218045 76.25 -2.14298496e+00 -8.08011921e-01 2.29025496e+00 -2.78102616 0.71136675 76.50 -2.10552901e+00 -8.32059175e-01 2.26397325e+00 -2.76524989 0.70844237 76.75 -2.15031217e+00 -8.07829052e-01 2.29704815e+00 -2.78222604 0.73100654 77.00 -1.83316019e+00 -8.58979506e-01 2.02443130e+00 -2.70339668 0.63509602 77.25 -1.82901549e+00 -8.54296071e-01 2.01869250e+00 -2.70462635 0.60727314 77.50 -1.98659168e+00 -6.98834996e-01 2.10592422e+00 -2.80333665 0.67006313 77.75 -2.04588012e+00 -5.53406774e-01 2.11940665e+00 -2.87741658 0.67421677 78.00 -1.98841926e+00 -7.09004384e-01 2.11104201e+00 -2.79907966 0.65025676 78.25 -1.81153392e+00 -7.59514982e-01 1.96431111e+00 -2.74458857 0.60362663 78.50 -1.81837255e+00 -6.57357569e-01 1.93354537e+00 -2.79470208 0.43849180 78.75 -1.67841550e+00 -7.24618101e-01 1.82815480e+00 -2.73403759 0.37978041 79.00 -1.49663137e+00 -8.29622295e-01 1.71119216e+00 -2.63543389 0.37337558 79.25 -1.89679807e+00 -7.79504485e-01 2.05072430e+00 -2.75167550 0.42015277 79.50 -2.47948358e+00 -8.57433809e-01 2.62355324e+00 -2.80865415 0.45495565 79.75 -2.38225157e+00 -1.10258118e+00 2.62503482e+00 -2.70811940 0.41660633 80.00 -3.24420471e+00 -1.25598642e+00 3.47884551e+00 -2.77221470 0.54917108 80.25 -4.38131997e+00 -7.68589904e-01 4.44822382e+00 -2.96793534 0.50988600 80.50 -6.67702157e+00 2.69813758e+00 7.20156674e+00 2.75756283 0.56314503 80.75 -3.64521057e+00 5.84144485e+00 6.88549476e+00 2.12869457 0.47507140 81.00 1.29327906e+00 4.71953606e+00 4.89352546e+00 1.30333518 0.53910644 81.25 1.30082908e+00 2.66358318e+00 2.96425904e+00 1.11649140 0.53562350 81.50 8.53505404e-01 1.73661279e+00 1.93501820e+00 1.11399026 0.61292647 81.75 7.47730041e-01 1.07524907e+00 1.30967964e+00 0.96316313 0.55758528 82.00 4.70862423e-01 7.11378286e-01 8.53094653e-01 0.98609988 0.52284597 82.25 2.11727153e-01 5.37698104e-01 5.77882028e-01 1.19567574 0.24518575 82.50 -1.28663282e-03 4.24940962e-01 4.24942910e-01 1.57382411 0.18010955 82.75 -3.04581529e-02 2.83060498e-01 2.84694475e-01 1.67798688 0.07320226 83.00 -7.54801822e-02 5.11275435e-02 9.11662416e-02 2.54622085 0.00965239 83.25 -1.67557798e-01 4.17765335e-02 1.72687273e-01 2.89724834 0.01740893 83.50 -3.79080302e-01 5.02927348e-01 6.29791864e-01 2.21669161 0.22961980 83.75 -2.12233764e-01 2.89597996e-01 3.59040625e-01 2.20323499 0.12989053 84.00 -1.02724908e-01 8.13033900e-02 1.31006290e-01 2.47207637 0.03073262 84.25 -6.24404730e-02 -5.47300944e-02 8.30312947e-02 -2.42190449 0.00850516 84.50 -1.33801371e-01 -1.23115015e-01 1.81824403e-01 -2.39776521 0.05194975 84.75 -2.44974197e-01 -1.19788521e-01 2.72693321e-01 -2.68679643 0.08158624 85.00 -3.02798653e-01 -9.34207575e-02 3.16882411e-01 -2.84233382 0.11177793 85.25 -3.52283714e-01 -8.64089772e-02 3.62726242e-01 -2.90105904 0.12430429 85.50 -2.62998093e-01 -4.89093347e-02 2.67507234e-01 -2.95772470 0.11373538 85.75 -1.91905602e-01 -1.36872652e-01 2.35715682e-01 -2.52204319 0.08028430 86.00 -2.15972699e-01 -1.29115474e-01 2.51624745e-01 -2.60276851 0.12144137 86.25 -8.96014641e-02 -1.61158085e-01 1.84391840e-01 -2.07822287 0.07584470 86.50 -5.88416094e-02 -2.01602753e-01 2.10014297e-01 -1.85477697 0.10838781 86.75 -1.97864769e-01 -2.73487627e-01 3.37558808e-01 -2.19711214 0.21281769 87.00 -1.45696257e-01 -3.95327544e-01 4.21320860e-01 -1.92389644 0.36456898 87.25 -2.13655466e-01 -2.89005491e-01 3.59406221e-01 -2.20740011 0.29693821 87.50 -2.09228448e-01 -2.76368833e-01 3.46635652e-01 -2.21880206 0.31397773 87.75 -2.06805647e-01 -2.54029259e-01 3.27565933e-01 -2.25407690 0.20177444 88.00 -2.30818841e-01 -2.37882247e-01 3.31459350e-01 -2.34112546 0.20793907 88.25 -1.47868943e-01 -2.39120271e-01 2.81147165e-01 -2.12462632 0.20070135 88.50 -1.04743417e-01 -2.15512126e-01 2.39617737e-01 -2.02319832 0.21359640 88.75 7.23029730e-02 -4.17082483e-01 4.23303104e-01 -1.39914806 0.34329398 89.00 -7.93617187e-02 -5.62329830e-01 5.67902386e-01 -1.71100057 0.35366701 89.25 -3.54806027e-01 -3.81951934e-01 5.21320053e-01 -2.31936607 0.35829653 89.50 -2.92328351e-01 -3.81170380e-01 4.80361035e-01 -2.22504051 0.32121269 89.75 -2.20736923e-01 -4.43146344e-01 4.95079258e-01 -2.03293314 0.38649081 90.00 -1.51476784e-01 -4.15920849e-01 4.42645873e-01 -1.92006168 0.32311622 90.25 -1.28750454e-01 -3.18495752e-01 3.43534894e-01 -1.95495720 0.32752007 90.50 -1.24899855e-01 -3.01624198e-01 3.26461530e-01 -1.96339076 0.28350881 90.75 -9.04990232e-02 -4.26300523e-01 4.35800653e-01 -1.77998008 0.44460609 91.00 -7.11138500e-02 -4.47291049e-01 4.52908890e-01 -1.72846456 0.44140166 91.25 -9.17448448e-02 -5.07509227e-01 5.15735138e-01 -1.74963958 0.48230813 91.50 -1.63098022e-01 -4.63644212e-01 4.91494578e-01 -1.90905075 0.38415832 91.75 -1.93443256e-01 -3.55987748e-01 4.05151293e-01 -2.06855719 0.39516331 92.00 -1.49304662e-01 -3.67386240e-01 3.96565923e-01 -1.95680516 0.29985145 92.25 -9.77077358e-02 -3.93888951e-01 4.05826696e-01 -1.81394742 0.38551290 92.50 -3.38387808e-02 -3.27332058e-01 3.29076495e-01 -1.67380794 0.32427226 92.75 -2.46866170e-02 -2.44327393e-01 2.45571383e-01 -1.67149367 0.25308102 93.00 -6.46741117e-02 -2.33161254e-01 2.41964690e-01 -1.84137323 0.19017892 93.25 -8.32049719e-02 -2.70597481e-01 2.83100802e-01 -1.86910690 0.30921967 93.50 -2.23810500e-02 -3.13798657e-01 3.14595786e-01 -1.64199872 0.35880902 93.75 4.95583654e-02 -3.31267003e-01 3.34953517e-01 -1.42229517 0.48251087 94.00 6.59787497e-02 -3.48666734e-01 3.54854459e-01 -1.38377615 0.45486405 94.25 4.08061523e-02 -3.55528941e-01 3.57863060e-01 -1.45652049 0.51054038 94.50 2.86431135e-02 -2.84364908e-01 2.85803829e-01 -1.47040831 0.34193923 94.75 4.12720944e-02 -2.85874462e-01 2.88838352e-01 -1.42741562 0.34230618 95.00 5.17462818e-02 -2.17301002e-01 2.23377267e-01 -1.33701853 0.16471273 95.25 1.20585614e-01 -1.44731815e-01 1.88383090e-01 -0.87615687 0.14781268 95.50 2.35397934e-01 -7.71530809e-02 2.47719166e-01 -0.31672257 0.20983926 95.75 3.09747595e-01 -1.06366421e-01 3.27501737e-01 -0.33078042 0.41844924 96.00 2.99192629e-01 -8.39445065e-02 3.10745731e-01 -0.27353728 0.35260098 96.25 3.33196136e-01 -1.34987091e-01 3.59501293e-01 -0.38491925 0.44352795 96.50 4.06151519e-01 -1.72565755e-01 4.41291283e-01 -0.40176921 0.52202354 96.75 4.92639932e-01 -1.93227359e-01 5.29179473e-01 -0.37378880 0.64851219 97.00 5.70592322e-01 -1.68318821e-01 5.94900684e-01 -0.28685381 0.67063839 97.25 6.47610102e-01 -1.35481887e-01 6.61629947e-01 -0.20622860 0.72461528 97.50 6.83202252e-01 -1.78705562e-01 7.06187648e-01 -0.25583856 0.60938340 97.75 7.44397783e-01 -2.62267755e-01 7.89248018e-01 -0.33874196 0.58646220 98.00 9.81100974e-01 -4.79182309e-01 1.09186758e+00 -0.45433498 0.64723461 98.25 9.99262285e-01 -5.93682453e-01 1.16231836e+00 -0.53608530 0.63089148 98.50 9.37504193e-01 -9.83545542e-01 1.35877737e+00 -0.80936034 0.67412515 98.75 7.25064754e-01 -1.17047681e+00 1.37685688e+00 -1.01619002 0.56627441 99.00 -6.44034381e-04 -1.04092465e+00 1.04092485e+00 -1.57141504 0.25589557 99.25 1.12584551e-01 -5.35291644e-01 5.47003131e-01 -1.36349407 0.11080765 99.50 3.41524911e-01 -6.94056405e-02 3.48505965e-01 -0.20049245 0.06673470 99.75 3.49015498e-01 -2.79725014e-01 4.47278327e-01 -0.67563588 0.03401755 100.00 -1.42704669e+00 7.59466127e-01 1.61655531e+00 2.65252253 0.11172022 100.25 -3.78534826e-01 2.49252218e-01 4.53227628e-01 2.55928912 0.01382371 100.50 1.13352003e+00 -3.01039026e-01 1.17281377e+00 -0.25958659 0.44314511 100.75 1.12420588e+00 -3.15391388e-01 1.16760892e+00 -0.27351488 0.52174593 101.00 9.91209374e-01 -2.21692243e-01 1.01569852e+00 -0.22003706 0.52976210 101.25 1.06749216e+00 5.05258573e-03 1.06750412e+00 0.00473310 0.56976488 101.50 1.30351040e+00 3.38198186e-02 1.30394906e+00 0.02593937 0.69912882 101.75 1.53935714e+00 -2.01424606e-01 1.55247939e+00 -0.13011061 0.70307833 102.00 1.75228925e+00 -5.39987041e-01 1.83360400e+00 -0.29892694 0.74754452 102.25 1.64827050e+00 -6.26881293e-01 1.76345564e+00 -0.36343246 0.70083951 102.50 1.88974159e+00 -1.05780975e+00 2.16566035e+00 -0.51030882 0.74547352 102.75 1.70032565e+00 -1.49396012e+00 2.26340985e+00 -0.72088323 0.72051346 103.00 9.61108581e-01 -2.03144953e+00 2.24733551e+00 -1.12888737 0.68678515 103.25 7.02294221e-01 -1.05776437e+00 1.26967816e+00 -0.98468238 0.40415479 103.50 1.13421089e+00 -3.85182171e-01 1.19783123e+00 -0.32738319 0.61131455 103.75 1.38587839e+00 -4.59102882e-01 1.45994328e+00 -0.31989432 0.70619847 104.00 1.50420163e+00 -5.68256302e-01 1.60796075e+00 -0.36120512 0.82130697 104.25 1.56865485e+00 -6.95576492e-01 1.71595592e+00 -0.41737044 0.87559190 104.50 1.49162362e+00 -7.45828670e-01 1.66769345e+00 -0.46365665 0.92951017 104.75 1.43545552e+00 -6.16097331e-01 1.56208465e+00 -0.40542260 0.91988285 105.00 1.46815890e+00 -4.70764347e-01 1.54178780e+00 -0.31029196 0.93773962 105.25 1.52375652e+00 -3.63454204e-01 1.56650340e+00 -0.23414996 0.92291422 105.50 1.68738160e+00 -3.30668927e-01 1.71947626e+00 -0.19351344 0.94837348 105.75 2.04241223e+00 -3.41055133e-01 2.07069223e+00 -0.16545979 0.91805542 106.00 2.33054930e+00 -5.54427781e-01 2.39558974e+00 -0.23355439 0.89485148 106.25 1.52115045e+00 -8.16276454e-01 1.72632730e+00 -0.49251097 0.65498677 106.50 1.15994584e+00 -4.21566334e-01 1.23417686e+00 -0.34859422 0.60516274 106.75 1.58315786e+00 -8.91487124e-02 1.58566589e+00 -0.05625129 0.87999899 107.00 1.78088097e+00 -1.93593035e-02 1.78098619e+00 -0.01087020 0.94240283 107.25 1.90033101e+00 -1.96702370e-02 1.90043281e+00 -0.01035058 0.93096973 107.50 2.05007325e+00 2.77253956e-02 2.05026072e+00 0.01352328 0.92931492 107.75 2.25190880e+00 -6.03116717e-03 2.25191688e+00 -0.00267824 0.94676411 108.00 2.26787288e+00 5.69007207e-02 2.26858659e+00 0.02508464 0.93396064 108.25 2.46775066e+00 -4.78390111e-02 2.46821431e+00 -0.01938325 0.92342824 108.50 2.59116942e+00 -2.71290538e-01 2.60533252e+00 -0.10431805 0.93491241 108.75 2.56724810e+00 -3.27856776e-01 2.58809832e+00 -0.12701992 0.92672589 109.00 2.48130910e+00 -2.99997067e-01 2.49937854e+00 -0.12031876 0.90702646 109.25 2.40972940e+00 -3.16762350e-01 2.43045966e+00 -0.13070204 0.85193545 109.50 2.08385365e+00 -3.18606676e-01 2.10806932e+00 -0.15171810 0.72252476 109.75 1.73971263e+00 -5.01248616e-01 1.81048342e+00 -0.28052378 0.81829451 110.00 1.85444930e+00 -3.58377273e-01 1.88876056e+00 -0.19089940 0.88646988 110.25 2.01276165e+00 -2.53181552e-01 2.02862277e+00 -0.12513094 0.89118448 110.50 2.01766705e+00 -2.63170240e-01 2.03475770e+00 -0.12970072 0.87495987 110.75 2.31725357e+00 -4.92099074e-01 2.36892921e+00 -0.20925437 0.89382616 111.00 2.54902291e+00 -5.81322917e-01 2.61447015e+00 -0.22422238 0.88421460 111.25 2.81255319e+00 -6.58891254e-01 2.88870094e+00 -0.23011817 0.81742197 111.50 2.69308731e+00 -1.02602645e+00 2.88191768e+00 -0.36400763 0.79529176 111.75 2.41917713e+00 -1.49159215e+00 2.84205298e+00 -0.55251435 0.89740405 112.00 2.28569110e+00 -1.54486529e+00 2.75880274e+00 -0.59435769 0.88039578 112.25 2.09225819e+00 -1.74744615e+00 2.72600668e+00 -0.69583668 0.78745643 112.50 1.87720081e+00 -1.79307859e+00 2.59596103e+00 -0.76248234 0.76032907 112.75 1.64601740e+00 -1.42761535e+00 2.17886642e+00 -0.71446074 0.77531810 113.00 1.59386122e+00 -1.30907390e+00 2.06253923e+00 -0.68760785 0.75331360 113.25 1.71895971e+00 -1.44821483e+00 2.24769853e+00 -0.70012081 0.82609780 113.50 1.81173015e+00 -1.52078976e+00 2.36541067e+00 -0.69831554 0.86165560 113.75 2.03589498e+00 -1.38845587e+00 2.46428043e+00 -0.59853478 0.89403491 114.00 2.27351298e+00 -1.39305978e+00 2.66636022e+00 -0.54973050 0.87058499 114.25 2.50294450e+00 -1.64289572e+00 2.99396686e+00 -0.58085085 0.86104300 114.50 2.93357432e+00 -1.73139593e+00 3.40640429e+00 -0.53318255 0.84594111 114.75 3.04335930e+00 -2.10384925e+00 3.69975911e+00 -0.60485758 0.85632817 115.00 2.88316160e+00 -2.13438253e+00 3.58722868e+00 -0.63725922 0.75910179 115.25 2.45274012e+00 -2.45611220e+00 3.47108358e+00 -0.78608510 0.72084620 115.50 2.32149232e+00 -2.57046656e+00 3.46361443e+00 -0.83624888 0.77327130 115.75 1.80844381e+00 -2.58835057e+00 3.15753507e+00 -0.96095291 0.79862645 116.00 9.01132807e-01 -1.85242527e+00 2.05998051e+00 -1.11803839 0.67329352 116.25 6.42559749e-01 -1.59102131e+00 1.71587640e+00 -1.18696146 0.68826169 116.50 3.74177226e-01 -7.81772428e-01 8.66704520e-01 -1.12439302 0.26542345 116.75 4.11071969e-01 -6.10817609e-02 4.15585305e-01 -0.14751206 0.07109141 117.00 1.01790804e+00 1.89641598e-01 1.03542297e+00 0.18419351 0.34610509 117.25 1.36160085e+00 4.59515668e-01 1.43704959e+00 0.32547962 0.52562605 117.50 1.72317084e+00 3.05914162e-01 1.75011463e+00 0.17569923 0.59202526 117.75 1.67297586e+00 2.83641693e-01 1.69685027e+00 0.16794616 0.48774484 118.00 1.68148827e+00 4.97772489e-01 1.75361918e+00 0.28781145 0.39383987 118.25 1.80746483e+00 3.58980660e-01 1.84276863e+00 0.19605870 0.32023786 118.50 2.22514102e+00 8.77166642e-01 2.39179302e+00 0.37550264 0.30536044 118.75 2.13849727e+00 1.17592539e+00 2.44048583e+00 0.50275413 0.29468006 119.00 2.83379204e+00 4.46176213e-01 2.86870189e+00 0.15616643 0.35184376 119.25 2.89555446e+00 -2.30579051e-01 2.90472070e+00 -0.07946440 0.31996522 119.50 8.91309169e-01 -2.55869867e+00 2.70949643e+00 -1.23559691 0.24321372 119.75 -1.63835738e+00 -2.91638912e+00 3.34507704e+00 -2.08263563 0.24730609 120.00 -6.06131670e+00 1.16878481e+00 6.17297482e+00 2.95110374 0.45014883 120.25 -5.42079718e+00 3.92589238e+00 6.69310639e+00 2.51479076 0.48996061 120.50 -4.34446731e+00 7.57729177e+00 8.73440020e+00 2.09139239 0.61565523 120.75 -2.95192368e+00 9.11953025e+00 9.58538917e+00 1.88384520 0.63927062 121.00 9.83534917e-01 9.67665130e+00 9.72650612e+00 1.46950417 0.68550191 121.25 1.83852674e+00 8.40053818e+00 8.59937337e+00 1.35533536 0.71827973 121.50 2.68653973e+00 6.77388542e+00 7.28718186e+00 1.19322228 0.70564010 121.75 1.86235096e+00 5.65095611e+00 5.94992908e+00 1.25244212 0.62413455 122.00 3.46056495e-01 4.52390246e+00 4.53711898e+00 1.49444988 0.45412132 122.25 -2.14137699e+00 5.09147366e+00 5.52345901e+00 1.96891808 0.29574150 122.50 -9.28845663e+00 1.31108443e+01 1.60676590e+01 2.18717496 0.35428781 122.75 -1.16255221e+00 2.35136562e+01 2.35423779e+01 1.62019768 0.36772012 123.00 2.43019526e+01 1.13583625e+01 2.68253108e+01 0.43721668 0.42194538 123.25 1.75504808e+01 -2.60510065e+00 1.77427711e+01 -0.14735876 0.36879344 123.50 1.13731106e+01 5.76848711e-01 1.13877302e+01 0.05067697 0.42276303 123.75 7.40454307e+00 3.11010541e+00 8.03119006e+00 0.39765064 0.26325430 124.00 -1.24350262e+00 2.99512292e+00 3.24300171e+00 1.96431647 0.04552466 124.25 -3.80375967e+00 -2.36652989e+00 4.47984947e+00 -2.58504146 0.07374668 124.50 -2.34451988e+00 -8.25051587e+00 8.57716652e+00 -1.84766439 0.33771281 124.75 4.95401312e-01 -6.46894452e+00 6.48788607e+00 -1.49436404 0.38272486 125.00 1.96606520e+00 -4.91589804e+00 5.29447503e+00 -1.19034151 0.60278549 125.25 1.61299187e+00 -3.55607324e+00 3.90479189e+00 -1.14496269 0.57775374 125.50 1.96680048e+00 -2.50317924e+00 3.18342746e+00 -0.90482294 0.63617763 125.75 2.70594529e+00 -1.24060094e+00 2.97678192e+00 -0.42987711 0.56735044 126.00 2.78795530e+00 -1.55401570e-01 2.79228301e+00 -0.05568272 0.60565680 126.25 2.11211451e+00 2.15120503e-01 2.12304134e+00 0.10150077 0.42703125 126.50 1.76444281e+00 2.98722969e-01 1.78955129e+00 0.16771128 0.36040524 126.75 1.98344272e+00 6.34922640e-01 2.08258777e+00 0.30980400 0.35703816 127.00 2.25337511e+00 4.95453176e-01 2.30720030e+00 0.21642782 0.43615358 127.25 1.98041622e+00 7.86365484e-01 2.13082592e+00 0.37797867 0.30081942 127.50 1.45936191e+00 1.38567713e+00 2.01242101e+00 0.75950456 0.26578332 127.75 -1.02967087e-01 2.23928174e+00 2.24164782e+00 1.61674615 0.29330835 128.00 -1.25700304e+00 2.75350847e+00 3.02685737e+00 1.99905043 0.43211389 128.25 -3.26851449e+00 5.02229254e+00 5.99221239e+00 2.14773464 0.49212245 128.50 -4.26139544e+00 7.33185302e+00 8.48030423e+00 2.09729007 0.62233881 128.75 -3.73136094e+00 1.55500248e+01 1.59914454e+01 1.80630209 0.68689180 129.00 -1.05717365e+00 2.12215280e+01 2.12478438e+01 1.62057127 0.76070890 129.25 1.23428857e+01 2.39818702e+01 2.69717802e+01 1.09547721 0.80863664 129.50 1.80646739e+01 1.91201049e+01 2.63041984e+01 0.81377396 0.79576402 129.75 2.12164279e+01 9.58473299e+00 2.32809777e+01 0.42431656 0.84547003 130.00 2.07579522e+01 6.52412445e+00 2.17590620e+01 0.30451950 0.87765999 130.25 1.87040185e+01 3.26686923e+00 1.89871731e+01 0.17291707 0.81148061 130.50 1.83307631e+01 2.10843999e+00 1.84516231e+01 0.11451868 0.76539880 130.75 2.09070622e+01 1.77396741e+00 2.09821879e+01 0.08464740 0.79561494 131.00 2.16366810e+01 -9.86245977e-01 2.16591469e+01 -0.04555060 0.81591409 131.25 1.90329896e+01 -5.58369283e+00 1.98351284e+01 -0.28536244 0.80257619 131.50 1.58139675e+01 -6.97791312e+00 1.72850467e+01 -0.41555364 0.72313553 131.75 8.60216400e+00 -7.80783828e+00 1.16172098e+01 -0.73703094 0.56926073 132.00 6.39459205e+00 -6.71344690e+00 9.27152505e+00 -0.80971850 0.58405294 132.25 3.54889383e+00 -4.45160070e+00 5.69310076e+00 -0.89775436 0.60087879 132.50 4.61671004e+00 -3.25236122e+00 5.64728829e+00 -0.61372365 0.76791654 132.75 4.37550252e+00 -2.21612428e+00 4.90471499e+00 -0.46882176 0.66721305 133.00 3.55424614e+00 1.32652344e-01 3.55672072e+00 0.03730490 0.38366416 133.25 6.07021042e+00 2.75883417e+00 6.66772979e+00 0.42657938 0.58626618 133.50 8.16950581e+00 2.11293032e+00 8.43832327e+00 0.25309023 0.58252405 133.75 1.06484323e+01 -6.81866564e-02 1.06486507e+01 -0.00640336 0.72094543 134.00 1.19006258e+01 -3.50610623e-02 1.19006774e+01 -0.00294614 0.78911141 134.25 1.30391099e+01 -1.54111366e+00 1.31298674e+01 -0.11764585 0.84262687 134.50 1.27949637e+01 -1.14735245e+00 1.28463035e+01 -0.08943299 0.79690063 134.75 1.37932219e+01 -1.28718446e+00 1.38531518e+01 -0.09305058 0.80715485 135.00 1.35217121e+01 -1.09326532e+00 1.35658368e+01 -0.08067709 0.81480940 135.25 1.28322304e+01 -1.41195873e+00 1.29096772e+01 -0.10959136 0.79144166 135.50 1.50082480e+01 -1.62594743e+00 1.50960661e+01 -0.10791604 0.79372629 135.75 1.72976448e+01 -2.45911892e+00 1.74715706e+01 -0.14121865 0.80082764 136.00 1.69996815e+01 -4.62964977e+00 1.76188203e+01 -0.26588917 0.68766162 136.25 1.43249043e+01 -9.70658566e+00 1.73037767e+01 -0.59553515 0.50848576 136.50 -1.12560521e+00 -9.79084974e+00 9.85533996e+00 -1.68525883 0.15828617 136.75 -1.70000764e+01 -9.48883160e+00 1.94689631e+01 -2.63250307 0.36816537 137.00 -2.04502354e+01 7.48940609e+00 2.17785062e+01 2.79053644 0.25508491 137.25 -2.53171704e+01 1.93452300e+01 3.18621569e+01 2.48911897 0.34517038 137.50 -1.18286456e+01 1.77573776e+01 2.13363848e+01 2.15842432 0.25339847 137.75 -1.00801455e+01 1.92226795e+01 2.17053159e+01 2.05376357 0.35901682 138.00 -5.12904177e+00 9.20333636e+00 1.05360557e+01 2.07922872 0.27904745 138.25 -5.92850522e+00 6.90469467e+00 9.10065836e+00 2.28027320 0.37486480 138.50 -5.86009453e+00 3.11028873e+00 6.63435030e+00 2.65364293 0.40981413 138.75 -5.65704366e+00 1.52045300e+00 5.85780849e+00 2.87902605 0.51253132 139.00 -4.62071475e+00 5.03047548e-01 4.64801696e+00 3.03315182 0.54885252 139.25 -4.03056587e+00 -2.74514378e-02 4.03065935e+00 -3.13478194 0.49915746 139.50 -3.42639774e+00 -1.63369705e+00 3.79594093e+00 -2.69667894 0.55612040 139.75 -3.36949476e+00 -1.84755283e+00 3.84277847e+00 -2.64004213 0.61975865 140.00 -2.65709452e+00 -1.64800846e+00 3.12667286e+00 -2.58643115 0.42856180 140.25 -2.70274257e+00 -1.65067950e+00 3.16694809e+00 -2.59331175 0.40588872 140.50 -2.74038684e+00 -1.72227976e+00 3.23665995e+00 -2.58049440 0.39505950 140.75 -2.60229256e+00 -1.75790794e+00 3.14040872e+00 -2.54748392 0.40510019 141.00 -2.77041348e+00 -2.02270922e+00 3.43023956e+00 -2.51094252 0.42511278 141.25 -2.30169481e+00 -2.14313534e+00 3.14496869e+00 -2.39185216 0.35170473 141.50 -3.19815526e-01 -3.07576945e+00 3.09235180e+00 -1.67440304 0.19704674 141.75 4.65120468e-01 -2.38124043e+00 2.42624051e+00 -1.37789808 0.09148890 142.00 2.75990606e+00 -1.55588792e+00 3.16825956e+00 -0.51333600 0.09861671 142.25 4.37234058e+00 -3.46126620e+00 5.57653350e+00 -0.66961503 0.23999817 142.50 3.17361294e+00 -7.17130680e+00 7.84215916e+00 -1.15416077 0.29792140 142.75 1.20561540e+00 -9.53752060e+00 9.61341810e+00 -1.44505560 0.39016948 143.00 -4.35401606e+00 -1.07737783e+01 1.16203165e+01 -1.95485869 0.50228252 143.25 -7.16888191e+00 -1.06381218e+01 1.28281917e+01 -2.16378033 0.55571560 143.50 -1.10020603e+01 -8.87334466e+00 1.41344110e+01 -2.46289076 0.62018803 143.75 -9.56188571e+00 -6.06764414e+00 1.13245734e+01 -2.57614423 0.56272128 144.00 -1.00548198e+01 -4.68444242e+00 1.10924930e+01 -2.70560326 0.67332567 144.25 -8.90663097e+00 -3.48797058e+00 9.56525034e+00 -2.76833553 0.64349039 144.50 -8.21031103e+00 -2.39079322e+00 8.55132150e+00 -2.85823422 0.62107868 144.75 -7.64630976e+00 -1.71875974e+00 7.83710329e+00 -2.92048485 0.59438301 145.00 -7.16918693e+00 -6.90593619e-01 7.20237188e+00 -3.04556093 0.62043810 145.25 -5.78714798e+00 -2.25034391e-01 5.79152158e+00 -3.10272704 0.53053804 145.50 -6.01906109e+00 -6.75193029e-02 6.01943978e+00 -3.13037554 0.63076341 145.75 -5.57299886e+00 -5.64205819e-01 5.60148592e+00 -3.04069724 0.57175805 146.00 -5.72899795e+00 -5.17964544e-01 5.75236515e+00 -3.05142678 0.52301515 146.25 -4.90865595e+00 9.91600412e-02 4.90965741e+00 3.12139434 0.34319696 146.50 -5.67506544e+00 9.14252323e-01 5.74823669e+00 2.98186516 0.38738862 146.75 -4.66848677e+00 -3.94120280e-01 4.68509333e+00 -3.05737094 0.24628094 147.00 -4.92698168e+00 1.46644110e-01 4.92916352e+00 3.11183796 0.26360922 147.25 -4.13233620e+00 1.51335604e+00 4.40073278e+00 2.79053911 0.25641791 147.50 -3.85455256e+00 9.98820708e-01 3.98186115e+00 2.88804199 0.23974614 147.75 -3.42948484e+00 3.83452927e-01 3.45085532e+00 3.03024448 0.22328909 148.00 -4.19140595e+00 2.36421891e-01 4.19806850e+00 3.08524602 0.26079559 148.25 -3.91943994e+00 1.89435980e+00 4.35322966e+00 2.69137454 0.33597917 148.50 -2.77564252e+00 3.27466178e+00 4.29273819e+00 2.27390238 0.32543990 148.75 -1.62666494e+00 3.52452820e+00 3.88179570e+00 2.00319466 0.24120262 149.00 -2.05000885e+00 2.98431081e+00 3.62058659e+00 2.17269565 0.16776035 149.25 -2.56697781e+00 2.46060937e+00 3.55583655e+00 2.37734829 0.14937446 149.50 -3.23153497e+00 1.17512924e+00 3.43856758e+00 2.79281465 0.13495701 149.75 -4.04986567e+00 -5.91873315e-01 4.09288724e+00 -2.99647362 0.27465955 150.00 -3.60845313e+00 -1.11150673e+00 3.77576234e+00 -2.84278655 0.19685621 150.25 -3.36573849e+00 -6.86334300e-01 3.43500369e+00 -2.94043274 0.23433764 150.50 -3.31289529e+00 -7.58979671e-01 3.39872407e+00 -2.91638055 0.32164282 150.75 -2.67820184e+00 -8.21789616e-01 2.80144663e+00 -2.84386903 0.21823567 151.00 -2.87464402e+00 -1.08760054e+00 3.07350828e+00 -2.77989463 0.27137938 151.25 -2.58659140e+00 -5.75303969e-01 2.64979806e+00 -2.92273734 0.28183450 151.50 -2.84676080e+00 -4.79486261e-01 2.88685887e+00 -2.97472663 0.30161169 151.75 -2.75535363e+00 -1.01814697e+00 2.93744734e+00 -2.78763861 0.24795762 152.00 -2.28811921e+00 -3.58647856e-01 2.31605652e+00 -2.98611419 0.18108026 152.25 -1.40924701e+00 -2.03813759e-01 1.42390912e+00 -2.99796255 0.10100466 152.50 -1.61255963e+00 4.95776051e-02 1.61332158e+00 3.11085767 0.10842678 152.75 -1.92924316e+00 -6.62181727e-01 2.03972150e+00 -2.81095818 0.21617965 153.00 -1.73670247e+00 -5.94578085e-01 1.83566298e+00 -2.81173989 0.18119338 153.25 -2.21935049e+00 -1.37655961e+00 2.61159586e+00 -2.58641393 0.33672139 153.50 -2.05414235e+00 -9.66217518e-01 2.27003900e+00 -2.70192454 0.25645685 153.75 -1.22079434e+00 -5.19624117e-01 1.32678109e+00 -2.73917643 0.11783583 154.00 -1.14079645e+00 -8.74985209e-01 1.43771195e+00 -2.48730315 0.10161533 154.25 -1.50305069e+00 -1.32999195e+00 2.00699775e+00 -2.41720450 0.19914883 154.50 -1.13899707e+00 -1.31783594e+00 1.74183980e+00 -2.28353021 0.13319687 154.75 -2.01506683e+00 -1.08158021e+00 2.28698712e+00 -2.64898173 0.20739104 155.00 -1.61737883e+00 -7.07936926e-01 1.76552796e+00 -2.72900906 0.12982527 155.25 -2.12653105e+00 -8.12581574e-01 2.27649360e+00 -2.77659792 0.23717190 155.50 -1.95281434e+00 -8.60122606e-01 2.13384506e+00 -2.72670646 0.19354134 155.75 -2.19118242e+00 -1.02433431e+00 2.41878920e+00 -2.70429769 0.23328132 156.00 -2.21940432e+00 -9.79218239e-01 2.42582437e+00 -2.72607443 0.20291176 156.25 -2.18026012e+00 -4.07773518e-01 2.21806525e+00 -2.95669902 0.19189906 156.50 -1.55635680e+00 -1.01265840e+00 1.85680465e+00 -2.56475392 0.14240284 156.75 -1.47998685e+00 -9.31983016e-01 1.74898639e+00 -2.57960362 0.15014770 157.00 -1.21207463e+00 -1.72269326e+00 2.10637057e+00 -2.18392952 0.17924180 157.25 -1.53156751e+00 -2.10825788e+00 2.60584925e+00 -2.19906161 0.21754112 157.50 -1.51298673e+00 -5.54328352e-01 1.61133757e+00 -2.79040042 0.10234120 157.75 -1.08380520e+00 -2.91354654e-01 1.12228394e+00 -2.87897569 0.06880636 158.00 -1.05609596e+00 -6.99407184e-01 1.26669219e+00 -2.55664896 0.07754281 158.25 -1.03764909e+00 -3.69090907e-01 1.10133725e+00 -2.79984968 0.06043948 158.50 -1.62197557e+00 4.06741532e-01 1.67219718e+00 2.89589016 0.11483468 158.75 -1.81494621e+00 6.77091131e-01 1.93713246e+00 2.78452036 0.14827945 159.00 -1.64352584e+00 5.94361893e-01 1.74769655e+00 2.79458749 0.12538539 159.25 -1.42187722e+00 4.59805981e-01 1.49437491e+00 2.82882712 0.09740337 159.50 -7.98043899e-01 5.67258756e-01 9.79110086e-01 2.52364746 0.04358060 159.75 -9.37809118e-01 7.89119595e-01 1.22564093e+00 2.44208323 0.07640344 160.00 1.30225807e-01 8.59128935e-01 8.68942626e-01 1.42036259 0.02948735 160.25 3.05441132e-01 1.40440891e-01 3.36181393e-01 0.43097111 0.00560312 160.50 -9.40177932e-02 -2.56358602e-01 2.73055082e-01 -1.92230865 0.00476367 160.75 1.88826189e-01 -4.27236481e-01 4.67104207e-01 -1.15463924 0.01564800 161.00 8.13007620e-01 -5.88575018e-01 1.00369415e+00 -0.62661811 0.10167055 161.25 7.41137701e-01 -5.12966725e-01 9.01343415e-01 -0.60542735 0.08821949 161.50 1.32141642e+00 -3.45110926e-01 1.36573896e+00 -0.25546125 0.21335442 161.75 1.30274060e+00 -7.82158819e-01 1.51950831e+00 -0.54070982 0.26608385 162.00 8.62370996e-01 -6.57752717e-01 1.08458396e+00 -0.65159608 0.14244391 162.25 6.41168373e-01 -7.48631004e-01 9.85669956e-01 -0.86256702 0.11475228 162.50 6.09321240e-01 -7.46237843e-01 9.63401937e-01 -0.88606057 0.15156124 162.75 7.42625833e-01 -6.51623709e-01 9.87981066e-01 -0.72022100 0.15617629 163.00 7.75266207e-01 -8.25322471e-01 1.13234044e+00 -0.81666163 0.13558631 163.25 6.50905875e-01 -1.27970707e+00 1.43573279e+00 -1.10026332 0.17118431 163.50 4.12523007e-01 -1.40809540e+00 1.46727907e+00 -1.28580587 0.16961909 163.75 4.87479548e-01 -1.34163847e+00 1.42745581e+00 -1.22228142 0.21262446 164.00 2.89914006e-01 -9.63594823e-01 1.00626294e+00 -1.27854419 0.25732141 164.25 4.65227611e-01 -6.86507709e-01 8.29294618e-01 -0.97521274 0.19598724 164.50 7.03785578e-01 -3.88581322e-01 8.03933818e-01 -0.50447726 0.20199739 164.75 7.66132550e-01 -3.12029380e-01 8.27237220e-01 -0.38676523 0.14868879 165.00 7.45769457e-01 -2.04397332e-01 7.73272495e-01 -0.26750675 0.15344637 165.25 7.34710106e-01 -1.00195202e-01 7.41510633e-01 -0.13553768 0.09422752 165.50 9.24350238e-01 1.97695459e-01 9.45254917e-01 0.21070067 0.12848754 165.75 9.70052965e-01 -8.54319388e-02 9.73807666e-01 -0.08784271 0.09834615 166.00 1.16796890e+00 -5.37176303e-02 1.16920354e+00 -0.04595996 0.11353567 166.25 1.21255255e+00 1.46613801e-01 1.22138418e+00 0.12032922 0.13369250 166.50 1.67521977e+00 -1.07743579e-01 1.67868102e+00 -0.06422762 0.34234234 166.75 1.49193677e+00 -2.83495815e-01 1.51863267e+00 -0.18777995 0.28967456 167.00 1.66137175e+00 -2.01761901e-01 1.67357819e+00 -0.12085116 0.46869141 167.25 1.77214940e+00 -2.11413875e-01 1.78471548e+00 -0.11873683 0.48849882 167.50 1.84507749e+00 -2.71729027e-01 1.86497925e+00 -0.14622133 0.60420845 167.75 1.98408331e+00 -2.92197234e-01 2.00548393e+00 -0.14621959 0.60569201 168.00 2.01017812e+00 -2.14114896e-01 2.02154923e+00 -0.10611528 0.65787806 168.25 1.88994541e+00 -4.77446896e-02 1.89054838e+00 -0.02525710 0.66152854 168.50 1.95022219e+00 1.89885705e-02 1.95031463e+00 0.00973631 0.70132977 168.75 2.16221189e+00 -2.87599374e-01 2.18125506e+00 -0.13223546 0.59136963 169.00 2.19980891e+00 -3.90358884e-01 2.23417531e+00 -0.17562310 0.63093232 169.25 1.82629683e+00 -5.79774414e-01 1.91611546e+00 -0.30739630 0.52237875 169.50 1.70517572e+00 -6.24760633e-01 1.81602590e+00 -0.35120157 0.53604119 169.75 1.67897241e+00 -4.20972706e-01 1.73094378e+00 -0.24566782 0.58296858 170.00 1.67679345e+00 -2.44376331e-01 1.69450761e+00 -0.14472137 0.58124597 170.25 1.84719531e+00 -4.60614737e-01 1.90375851e+00 -0.24437526 0.65655745 170.50 1.78419157e+00 -5.70256278e-01 1.87310752e+00 -0.30935463 0.64724937 170.75 1.89900560e+00 -3.04088702e-01 1.92319843e+00 -0.15878250 0.60076825 171.00 1.81639132e+00 -2.87575014e-01 1.83901517e+00 -0.15701889 0.58264486 171.25 1.42479792e+00 -6.84957727e-02 1.42644341e+00 -0.04803704 0.40258235 171.50 1.35372276e+00 -2.17013885e-01 1.37100705e+00 -0.15895649 0.45078750 171.75 1.38505693e+00 -6.45198075e-02 1.38655887e+00 -0.04654913 0.52360505 172.00 1.44929364e+00 -2.46612258e-01 1.47012573e+00 -0.16854596 0.48965682 172.25 1.28949574e+00 -2.30734114e-01 1.30997615e+00 -0.17705981 0.33061917 172.50 9.49839826e-01 -4.66243057e-01 1.05810126e+00 -0.45631288 0.26323362 172.75 8.92840443e-01 -6.66846906e-01 1.11438272e+00 -0.64150292 0.34549294 173.00 8.56034013e-01 -5.30022985e-01 1.00683593e+00 -0.55438955 0.30068038 173.25 9.64512404e-01 -3.32619427e-01 1.02025480e+00 -0.33208629 0.40033068 173.50 1.02104315e+00 -1.70158584e-01 1.03512466e+00 -0.16513412 0.41438058 173.75 1.08759882e+00 1.25687932e-01 1.09483727e+00 0.11505423 0.43922914 174.00 1.09107348e+00 2.29166149e-01 1.11488047e+00 0.20702794 0.39532640 174.25 1.11276072e+00 2.53280406e-01 1.14122188e+00 0.22380151 0.43587450 174.50 1.30655479e+00 3.91212672e-01 1.36386685e+00 0.29092743 0.48921163 174.75 1.60137856e+00 7.35527105e-01 1.76221832e+00 0.43056802 0.58111467 175.00 1.65261245e+00 5.60189313e-01 1.74497564e+00 0.32681672 0.50665793 175.25 1.04164669e+00 1.06243444e+00 1.48788264e+00 0.79527757 0.41603229 175.50 7.90517590e-01 1.45732197e+00 1.65792201e+00 1.07377169 0.32656892 175.75 2.51989995e+00 3.61401368e-01 2.54568393e+00 0.14244757 0.26678290 176.00 2.13694739e+00 -1.41196265e+00 2.56128535e+00 -0.58388700 0.40061485 176.25 1.65679335e+00 -1.48125826e+00 2.22240641e+00 -0.72951879 0.62803115 176.50 1.70189151e+00 -1.17083304e+00 2.06574072e+00 -0.60259954 0.55840642 176.75 1.78395779e+00 -9.08149123e-01 2.00180924e+00 -0.47087268 0.56946257 177.00 1.78748296e+00 -8.62409067e-01 1.98465229e+00 -0.44952650 0.59029893 177.25 1.93605824e+00 -9.64187290e-01 2.16286353e+00 -0.46205886 0.64496962 177.50 1.78537696e+00 -1.28979225e+00 2.20252922e+00 -0.62561509 0.65444690 177.75 1.78188525e+00 -1.34624175e+00 2.23326708e+00 -0.64702163 0.74245402 178.00 1.78972567e+00 -1.28543523e+00 2.20351122e+00 -0.62285658 0.71427181 178.25 1.96581693e+00 -1.26278460e+00 2.33646339e+00 -0.57099371 0.77746356 178.50 1.89168512e+00 -1.28395411e+00 2.28626568e+00 -0.59631157 0.73578375 178.75 1.92732205e+00 -1.36896856e+00 2.36403155e+00 -0.61760246 0.78446484 179.00 2.03796084e+00 -1.42456726e+00 2.48649880e+00 -0.61006527 0.77451656 179.25 2.10861485e+00 -1.40412961e+00 2.53334494e+00 -0.58747263 0.82199968 179.50 2.28902090e+00 -1.47612418e+00 2.72370323e+00 -0.57276145 0.79370843 179.75 2.38636059e+00 -1.54783199e+00 2.84438055e+00 -0.57540177 0.78919162 180.00 2.54108946e+00 -1.66743192e+00 3.03931980e+00 -0.58071288 0.81673912 180.25 2.70657100e+00 -1.63380571e+00 3.16146290e+00 -0.54309470 0.84291207 180.50 2.83783102e+00 -1.88058482e+00 3.40439189e+00 -0.58524021 0.84572848 180.75 2.77961877e+00 -1.96767849e+00 3.40558940e+00 -0.61600506 0.85711970 181.00 2.52419238e+00 -2.30151846e+00 3.41592365e+00 -0.73928763 0.76235411 181.25 2.33498903e+00 -2.37792226e+00 3.33266980e+00 -0.79450762 0.72140049 181.50 2.37299737e+00 -2.98986387e+00 3.81711966e+00 -0.89992049 0.66691997 181.75 2.14290010e+00 -3.21406411e+00 3.86293010e+00 -0.98275265 0.67589824 182.00 1.46971814e+00 -3.16369061e+00 3.48841076e+00 -1.13590204 0.61110878 182.25 1.21644736e+00 -2.74097052e+00 2.99877701e+00 -1.15310885 0.53589401 182.50 1.69402478e+00 -2.67135033e+00 3.16319973e+00 -1.00564749 0.42769531 182.75 1.41297048e+00 -2.48807491e+00 2.86129382e+00 -1.05431646 0.36844143 183.00 1.38817104e+00 -2.39311887e+00 2.76659299e+00 -1.04516185 0.28861616 183.25 1.48679631e+00 -2.31056490e+00 2.74759411e+00 -0.99902008 0.26221740 183.50 1.06217075e+00 -2.23872301e+00 2.47791998e+00 -1.12779370 0.22673996 183.75 6.93751818e-01 -1.84501126e+00 1.97113118e+00 -1.21113613 0.19007890 184.00 8.02744718e-02 -1.04759266e+00 1.05066378e+00 -1.49431822 0.07689471 184.25 2.25913394e-01 -1.02764871e+00 1.05218760e+00 -1.35440319 0.08008489 184.50 8.48383907e-01 -6.09286686e-01 1.04450252e+00 -0.62281898 0.08505728 184.75 6.27663269e-01 -7.07262634e-01 9.45611766e-01 -0.84495595 0.08727677 185.00 1.59046164e-01 -1.13994018e+00 1.15098189e+00 -1.43216972 0.20523515 185.25 -2.29619441e-01 -1.24261652e+00 1.26365379e+00 -1.75352218 0.26319868 185.50 -7.27745008e-01 -1.33752269e+00 1.52268833e+00 -2.06909788 0.49433275 185.75 -7.87324162e-01 -1.35384611e+00 1.56613493e+00 -2.09753639 0.45895939 186.00 -9.22870949e-01 -1.36095125e+00 1.64434762e+00 -2.16667759 0.57836793 186.25 -9.17580717e-01 -1.31020187e+00 1.59955722e+00 -2.18174734 0.61822574 186.50 -8.83240707e-01 -1.29059684e+00 1.56389077e+00 -2.17095249 0.70273147 186.75 -5.33901267e-01 -1.27216910e+00 1.37966111e+00 -1.96815049 0.62927134 187.00 -3.98733639e-01 -1.47040952e+00 1.52351326e+00 -1.83560005 0.76262428 187.25 -6.18645355e-01 -1.67801810e+00 1.78842580e+00 -1.92401136 0.72213865 187.50 -8.88191034e-01 -1.53700048e+00 1.77517712e+00 -2.09478704 0.77612008 187.75 -8.30197771e-01 -1.61714133e+00 1.81779383e+00 -2.04508554 0.73710422 188.00 -7.32624124e-01 -1.67237469e+00 1.82580810e+00 -1.98368858 0.77026141 188.25 -8.80136871e-01 -1.74765677e+00 1.95676905e+00 -2.03732751 0.73569442 188.50 -9.99668265e-01 -2.05544428e+00 2.28564823e+00 -2.02346558 0.79769280 188.75 -1.37866701e+00 -2.07594985e+00 2.49204544e+00 -2.15702950 0.60290183 189.00 -1.97333234e+00 -1.92821038e+00 2.75899180e+00 -2.36775913 0.65347393 189.25 -2.22040734e+00 -1.34414729e+00 2.59556173e+00 -2.59724080 0.57585205 189.50 -2.04628333e+00 -8.06245988e-01 2.19938811e+00 -2.76626499 0.57773057 189.75 -1.77508269e+00 -5.05529305e-01 1.84566477e+00 -2.86414590 0.49349834 190.00 -1.50084388e+00 -3.27415486e-01 1.53614233e+00 -2.92680356 0.47872027 190.25 -1.18559426e+00 -1.30224587e-01 1.19272469e+00 -3.03219212 0.38904148 190.50 -1.00790542e+00 -7.11803148e-02 1.01041574e+00 -3.07108769 0.38385429 190.75 -6.52207444e-01 -6.05454151e-02 6.55011677e-01 -3.04902642 0.17179950 191.00 -7.40103330e-01 2.53960809e-02 7.40538925e-01 3.10729188 0.28235922 191.25 -5.28590209e-01 1.44886749e-01 5.48087383e-01 2.87406305 0.13223016 191.50 -4.37218764e-01 3.41080613e-03 4.37232068e-01 3.13379167 0.08658192 191.75 -2.17299949e-01 -3.03810052e-01 3.73523514e-01 -2.19168362 0.08152403 192.00 -1.51642054e-01 -4.25540875e-01 4.51752531e-01 -1.91311810 0.13584410 192.25 8.08650280e-02 -4.80330451e-01 4.87089822e-01 -1.40400743 0.15754670 192.50 1.11760130e-01 -5.80365763e-01 5.91028549e-01 -1.38055660 0.26185201 192.75 1.36164848e-01 -6.12476045e-01 6.27429495e-01 -1.35203549 0.19723461 193.00 2.57050870e-01 -6.00798777e-01 6.53478631e-01 -1.16651543 0.18869468 193.25 1.81225836e-01 -7.56478061e-01 7.77882935e-01 -1.33566248 0.30376992 193.50 1.24321565e-01 -8.40977717e-01 8.50117269e-01 -1.42402950 0.31199813 193.75 1.77131253e-01 -1.18060711e+00 1.19382102e+00 -1.42187309 0.51564450 194.00 1.29992430e-01 -1.28025650e+00 1.28683905e+00 -1.46960688 0.59990656 194.25 1.75576107e-01 -1.50904778e+00 1.51922750e+00 -1.45496817 0.67121593 194.50 2.05903132e-01 -1.74197290e+00 1.75409968e+00 -1.45314113 0.68308453 194.75 -2.77450131e-01 -1.74307555e+00 1.76501869e+00 -1.72864488 0.66882959 195.00 -3.56047204e-01 -1.90022569e+00 1.93329441e+00 -1.75601966 0.64729647 195.25 -1.96712044e-01 -2.19065181e+00 2.19946607e+00 -1.66035226 0.76269514 195.50 -4.43275722e-01 -2.26043921e+00 2.30349274e+00 -1.76444062 0.71254288 195.75 -1.06404739e+00 -2.25440693e+00 2.49289941e+00 -2.01178223 0.72827688 196.00 -1.30323999e+00 -2.14993701e+00 2.51409300e+00 -2.11574456 0.58045568 196.25 -1.16316067e+00 -8.11759641e-01 1.41841336e+00 -2.53228337 0.23199202 196.50 -4.95192560e-01 -5.13366694e-01 7.13274865e-01 -2.33817654 0.09520274 196.75 -1.43896581e-01 -7.17525251e-01 7.31811937e-01 -1.76871651 0.28741378 197.00 -2.63745661e-02 -8.92425379e-01 8.92815028e-01 -1.60034153 0.38139835 197.25 1.16121764e-01 -8.95662865e-01 9.03159029e-01 -1.44186654 0.29860137 197.50 -7.87648671e-02 -1.58729639e+00 1.58924942e+00 -1.62037769 0.52983726 197.75 -2.54511042e-01 -1.91792632e+00 1.93473958e+00 -1.70272667 0.81302663 198.00 -2.83841309e-01 -2.18409111e+00 2.20245768e+00 -1.70003057 0.84620744 198.25 -3.24865650e-01 -2.43570214e+00 2.45727137e+00 -1.70339036 0.92157747 198.50 -6.49014070e-01 -2.61649209e+00 2.69578377e+00 -1.81393641 0.91614502 198.75 -9.42791503e-01 -2.88713863e+00 3.03717390e+00 -1.88642838 0.93514055 199.00 -1.39104250e+00 -3.01442600e+00 3.31990412e+00 -2.00314091 0.90255868 199.25 -1.82293770e+00 -3.25410135e+00 3.72991655e+00 -2.08143458 0.91438258 199.50 -2.14814641e+00 -2.90293502e+00 3.61131066e+00 -2.20786098 0.82767463 199.75 -2.36502585e+00 -2.71260134e+00 3.59882665e+00 -2.28784876 0.83338345 200.00 -1.48287788e+00 -2.27714585e+00 2.71741053e+00 -2.14801482 0.58233801 200.25 -1.78273202e+00 -2.49289958e+00 3.06474824e+00 -2.19160059 0.59921963 200.50 -3.39898435e+00 -2.63912045e+00 4.30326055e+00 -2.48138117 0.73776976 200.75 -4.28376797e+00 -1.87507203e+00 4.67616971e+00 -2.72900127 0.75053527 201.00 -4.05155554e+00 5.52753684e-02 4.05193259e+00 3.12795050 0.66563455 201.25 -3.77666520e+00 7.35839354e-01 3.84768237e+00 2.94916507 0.70283402 201.50 -3.75628372e+00 7.81019202e-01 3.83662070e+00 2.93659020 0.69104848 201.75 -4.11436936e+00 1.15010073e+00 4.27209164e+00 2.86901734 0.70484408 202.00 -2.95447551e+00 1.79571509e+00 3.45738603e+00 2.59546133 0.52669748 202.25 -2.45392636e+00 2.09459833e+00 3.22631319e+00 2.43502957 0.45994802 202.50 -6.57781995e-01 2.22391705e+00 2.31915592e+00 1.85837369 0.34280338 202.75 -2.79119131e-02 2.14183472e+00 2.14201658e+00 1.58382737 0.37078512 203.00 -1.85831261e-01 1.92460334e+00 1.93355405e+00 1.66705355 0.38033526 203.25 -6.90797665e-02 1.84951161e+00 1.85080123e+00 1.60812925 0.35827936 203.50 -3.21151809e-01 1.39674925e+00 1.43319466e+00 1.79679636 0.29385586 203.75 -7.67365129e-02 1.37885787e+00 1.38099150e+00 1.62639121 0.24484889 204.00 1.08643883e-01 9.00742432e-01 9.07270865e-01 1.45076026 0.09257031 204.25 5.17251568e-01 6.56205769e-01 8.35556818e-01 0.90326367 0.06442375 204.50 1.32755016e+00 4.16880031e-01 1.39146627e+00 0.30427091 0.14887217 204.75 1.31879765e+00 -2.25223413e-01 1.33789119e+00 -0.16914752 0.12932325 205.00 1.90541444e+00 -1.25538283e+00 2.28179540e+00 -0.58257172 0.28040532 205.25 1.20360920e+00 -2.19249544e+00 2.50114202e+00 -1.06874601 0.28960483 205.50 -4.20326561e-01 -3.43607996e+00 3.46169321e+00 -1.69251893 0.40545744 205.75 -1.43818819e+00 -2.17167911e+00 2.60472176e+00 -2.15573298 0.24875527 206.00 -1.79981123e+00 -1.57409717e+00 2.39104629e+00 -2.42299483 0.36325978 206.25 -1.84354239e+00 -1.22418955e+00 2.21298183e+00 -2.55540934 0.31597652 206.50 -1.18764886e+00 -1.06397516e+00 1.59453848e+00 -2.41106580 0.23873102 206.75 -1.34812748e+00 -8.19342225e-01 1.57758340e+00 -2.59548449 0.20588039 207.00 -1.05967934e+00 -6.67586967e-01 1.25243470e+00 -2.57941335 0.15385845 207.25 -7.58826046e-01 -7.18787249e-01 1.04521389e+00 -2.38328480 0.08873206 207.50 -1.16456772e+00 -9.37202463e-01 1.49484663e+00 -2.46395343 0.15768569 207.75 -8.91684144e-01 -1.16520053e+00 1.46723988e+00 -2.22399402 0.13241512 208.00 -9.53520132e-01 -1.70553084e+00 1.95397955e+00 -2.08058041 0.22109848 208.25 -1.08796940e+00 -1.31248856e+00 1.70478844e+00 -2.26293401 0.15250820 208.50 -1.05520229e+00 -1.25032059e+00 1.63607868e+00 -2.27176485 0.16191369 208.75 -1.43604074e+00 -1.07528372e+00 1.79400337e+00 -2.49887051 0.20455502 209.00 -1.34878175e+00 -1.08146364e+00 1.72880763e+00 -2.46575040 0.24067911 209.25 -7.62686607e-01 -8.53794986e-01 1.14483918e+00 -2.29989191 0.08325653 209.50 -6.39657026e-01 -6.56257890e-01 9.16425408e-01 -2.34338504 0.06740173 209.75 -6.47010719e-01 -1.33672091e+00 1.48507430e+00 -2.02158511 0.12518745 210.00 -2.04564016e-01 -1.63845416e+00 1.65117487e+00 -1.69500544 0.12479515 210.25 -1.04020999e+00 -9.38730129e-01 1.40116062e+00 -2.40742952 0.07468764 210.50 -2.11949377e+00 -1.87928066e-01 2.12780892e+00 -3.05315744 0.18549723 210.75 -3.83079349e+00 -7.18695278e-01 3.89762769e+00 -2.95613841 0.33752472 211.00 -5.50542804e+00 -1.14334425e-01 5.50661514e+00 -3.12082806 0.50070791 211.25 -6.23883995e+00 1.15714215e+00 6.34524246e+00 2.95820268 0.56173963 211.50 -6.92619470e+00 2.42987632e+00 7.34005940e+00 2.80418382 0.66850727 211.75 -4.83675398e+00 4.10085117e+00 6.34122775e+00 2.43834698 0.60710808 212.00 -4.18771480e+00 3.82120497e+00 5.66908834e+00 2.40192529 0.62694615 212.25 -3.02338327e+00 3.75123175e+00 4.81794417e+00 2.24916742 0.53429175 212.50 -2.87639733e+00 3.94310432e+00 4.88075130e+00 2.20103173 0.63636614 212.75 -2.30880806e+00 3.65805394e+00 4.32573153e+00 2.13381124 0.51059620 213.00 -1.76010885e+00 3.44402917e+00 3.86772803e+00 2.04325350 0.43997802 213.25 -1.48238693e+00 3.50496205e+00 3.80555252e+00 1.97092043 0.46797927 213.50 -9.28167512e-01 3.23811956e+00 3.36851796e+00 1.84994961 0.44949672 213.75 -7.47350131e-01 2.87958265e+00 2.97498378e+00 1.82472801 0.51734222 214.00 -1.21982461e+00 2.77631194e+00 3.03247095e+00 1.98477419 0.55845066 214.25 -1.50121102e+00 3.49110826e+00 3.80019360e+00 1.97690272 0.64204081 214.50 -1.53472256e+00 3.63911492e+00 3.94949753e+00 1.96989368 0.61913205 214.75 -7.35759268e-01 4.86328376e+00 4.91862487e+00 1.72094626 0.60308574 215.00 -1.54913616e-01 5.03242046e+00 5.03480426e+00 1.60156973 0.55973820 215.25 -8.16160820e-01 5.20163850e+00 5.26527887e+00 1.72643197 0.49614092 215.50 -4.19569411e-01 4.12246237e+00 4.14375850e+00 1.67222349 0.28987712 215.75 1.52487781e+00 8.27544117e-01 1.73495867e+00 0.49721775 0.05430615 216.00 1.16646387e+00 -7.62923084e-01 1.39380400e+00 -0.57921549 0.04428643 216.25 1.30708616e+00 -1.49826292e+00 1.98828218e+00 -0.85344019 0.11486830 216.50 4.03719921e-01 -1.47516260e+00 1.52940985e+00 -1.30365935 0.11408214 216.75 -9.89584116e-03 -1.34356888e+00 1.34360532e+00 -1.57816153 0.19135786 217.00 -2.75638275e-03 -9.56855227e-01 9.56859197e-01 -1.57367699 0.10979116 217.25 3.53427783e-02 -2.94194383e-01 2.96309715e-01 -1.45123520 0.02314009 217.50 -4.90179124e-02 -4.39763106e-01 4.42486548e-01 -1.68180247 0.05488063 217.75 -1.63931817e-01 -3.31505682e-01 3.69823820e-01 -2.03003973 0.06396794 218.00 -1.94508341e-01 -2.04426432e-01 2.82176648e-01 -2.33133818 0.02905946 218.25 -3.36438023e-01 -5.01979403e-02 3.40162279e-01 -2.99348116 0.05149776 218.50 -3.79509371e-01 1.81118434e-01 4.20513080e-01 2.69631530 0.05807150 218.75 -4.22149873e-01 4.97979371e-01 6.52835330e-01 2.27396852 0.14103269 219.00 -2.65134733e-01 3.62927861e-01 4.49458629e-01 2.20172881 0.05089159 219.25 -2.54480457e-01 2.00895602e-01 3.24221137e-01 2.47332750 0.03608180 219.50 -4.21255491e-01 3.61485790e-01 5.55092934e-01 2.43240606 0.09397490 219.75 -3.66789804e-01 5.56672838e-01 6.66647889e-01 2.15340030 0.17800743 220.00 -4.40809636e-01 4.98487533e-01 6.65434412e-01 2.29486612 0.11850278 220.25 -4.14464045e-01 4.38939338e-01 6.03695442e-01 2.32752272 0.09782046 220.50 -1.86771512e-01 6.46607646e-01 6.73041637e-01 1.85199105 0.13270439 220.75 -2.42199826e-01 5.44540777e-01 5.95974339e-01 1.98929926 0.13204906 221.00 -3.86292335e-01 4.83968455e-01 6.19231163e-01 2.24442450 0.10002056 221.25 -2.72926701e-01 3.68104290e-01 4.58246389e-01 2.20879554 0.06580805 221.50 -5.05850984e-01 2.60693790e-01 5.69075100e-01 2.66573515 0.07422790 221.75 -5.36403322e-01 3.67725453e-01 6.50346472e-01 2.54063806 0.09605414 222.00 -6.97053652e-01 3.06996108e-01 7.61662920e-01 2.72673427 0.13338271 222.25 -5.73669207e-01 2.13174092e-01 6.11996367e-01 2.78580825 0.10685986 222.50 -9.87512431e-01 3.23434597e-01 1.03912980e+00 2.82507905 0.22712460 222.75 -1.00019252e+00 4.19187659e-01 1.08448299e+00 2.74472402 0.26292167 223.00 -1.23631124e+00 2.62828122e-01 1.26393991e+00 2.93212060 0.34577985 223.25 -1.33366121e+00 4.33017685e-01 1.40219704e+00 2.82764712 0.38320044 223.50 -1.33561785e+00 1.05399227e+00 1.70140376e+00 2.47350754 0.35747436 223.75 -1.35833453e+00 1.25600274e+00 1.85003124e+00 2.39531706 0.41043983 224.00 -1.17402836e+00 1.46473609e+00 1.87717724e+00 2.24646885 0.46391779 224.25 -1.01571408e+00 1.46888435e+00 1.78586011e+00 2.17578583 0.42925080 224.50 -6.62349485e-01 1.33853486e+00 1.49344648e+00 2.03030076 0.34770598 224.75 -5.20613576e-01 1.58101072e+00 1.66452197e+00 1.88890494 0.35206057 225.00 -3.35166815e-01 1.71985683e+00 1.75221126e+00 1.76326462 0.31344118 225.25 -1.41239388e-01 1.68493298e+00 1.69084231e+00 1.65442574 0.32140936 225.50 4.28923675e-01 1.84219374e+00 1.89146856e+00 1.34203885 0.42159773 225.75 3.68006739e-01 1.53429618e+00 1.57781296e+00 1.33538961 0.37515893 226.00 5.22452977e-01 1.39602157e+00 1.49058154e+00 1.21268844 0.42177003 226.25 3.20813867e-01 1.32059517e+00 1.35900447e+00 1.33248157 0.32928910 226.50 1.99587002e-01 1.34007039e+00 1.35485188e+00 1.42294546 0.39872439 226.75 2.03503476e-01 1.31680329e+00 1.33243558e+00 1.41746578 0.32916305 227.00 5.47796910e-01 1.65534667e+00 1.74363243e+00 1.25121412 0.39899435 227.25 3.68730433e-01 1.37594877e+00 1.42449891e+00 1.30896570 0.27996334 227.50 -1.54493775e-04 1.34516180e+00 1.34516181e+00 1.57091118 0.37656646 227.75 3.30131928e-01 1.33271050e+00 1.37299103e+00 1.32796973 0.32349766 228.00 1.06457534e+00 1.07162618e+00 1.51053081e+00 0.78869880 0.38250236 228.25 9.77327781e-01 6.74737776e-01 1.18761974e+00 0.60424745 0.19815956 228.50 1.01042999e+00 1.05811184e+00 1.46306849e+00 0.80844503 0.33922985 228.75 9.29650902e-01 6.90544433e-01 1.15805976e+00 0.63887698 0.23577634 229.00 7.99095996e-01 5.56804549e-01 9.73953652e-01 0.60857042 0.23136459 229.25 7.42229998e-01 6.10043250e-01 9.60759146e-01 0.68795623 0.17781785 229.50 8.92664703e-01 6.83073551e-01 1.12402836e+00 0.65316295 0.30838883 229.75 7.59173771e-01 4.42803073e-01 8.78873925e-01 0.52802698 0.12635282 230.00 8.74588028e-01 3.45362642e-01 9.40308233e-01 0.37609007 0.14608810 230.25 7.52766709e-01 7.73348802e-01 1.07922476e+00 0.79888393 0.17096582 230.50 6.25535552e-01 8.63227531e-01 1.06604714e+00 0.94371932 0.19553058 230.75 6.98625904e-01 8.50659426e-01 1.10077228e+00 0.88321637 0.17434322 231.00 5.97974837e-01 9.80868312e-01 1.14877176e+00 1.02332001 0.20087396 231.25 7.91071389e-01 7.55134223e-01 1.09362774e+00 0.76216018 0.17586981 231.50 8.31810146e-01 6.61784825e-01 1.06295215e+00 0.67204980 0.18993142 231.75 9.01663376e-01 6.69618192e-01 1.12311414e+00 0.63877898 0.17685421 232.00 9.99961586e-01 5.11243309e-01 1.12307297e+00 0.47261732 0.20787564 232.25 6.32120207e-01 5.43860583e-01 8.33882659e-01 0.71048668 0.09715097 232.50 6.48949741e-01 6.25202302e-01 9.01118019e-01 0.76676248 0.12362893 232.75 8.70090956e-01 5.74094144e-01 1.04242139e+00 0.58324019 0.14076106 233.00 9.40102416e-01 5.43918633e-01 1.08611235e+00 0.52451594 0.16227059 233.25 5.16586101e-01 3.44695237e-01 6.21028185e-01 0.58841058 0.05604308 233.50 3.82195525e-01 3.83931353e-01 5.41734901e-01 0.78766388 0.04622889 233.75 9.29161149e-01 6.83695122e-02 9.31673136e-01 0.07344961 0.10979917 234.00 1.10922889e+00 1.71740990e-01 1.12244541e+00 0.15360947 0.15309265 234.25 1.19903352e+00 3.21945294e-01 1.24150319e+00 0.26231696 0.17563673 234.50 1.19105191e+00 1.77949774e-01 1.20427188e+00 0.14830854 0.17961889 234.75 1.26415770e+00 3.47990821e-01 1.31117974e+00 0.26862172 0.24202267 235.00 1.20512250e+00 2.73180913e-01 1.23569739e+00 0.22291587 0.22338010 235.25 1.08193314e+00 -4.47499297e-02 1.08285820e+00 -0.04133752 0.18467859 235.50 1.27815218e+00 -2.44765192e-02 1.27838652e+00 -0.01914759 0.20205045 235.75 1.18449309e+00 -1.94106730e-01 1.20029218e+00 -0.16242953 0.22726743 236.00 9.68379913e-01 8.54593547e-03 9.68417621e-01 0.00882475 0.13756162 236.25 9.47751075e-01 -1.98205536e-01 9.68254892e-01 -0.20616117 0.19090729 236.50 9.34378126e-01 -3.14628593e-01 9.85927804e-01 -0.32480006 0.17008641 236.75 7.95465384e-01 -3.10196603e-01 8.53807419e-01 -0.37181800 0.16953789 237.00 8.22443122e-01 -3.10098804e-01 8.78961863e-01 -0.36056313 0.16970960 237.25 1.14904949e+00 -3.03930832e-01 1.18856581e+00 -0.25858437 0.29218476 237.50 1.06086035e+00 -8.66034718e-02 1.06438942e+00 -0.08145450 0.20326602 237.75 9.35242046e-01 3.83673039e-01 1.01088213e+00 0.38930207 0.25331528 238.00 8.75814867e-01 2.19260183e-01 9.02843679e-01 0.24530797 0.17939646 238.25 1.00616782e+00 -2.46605987e-01 1.03594796e+00 -0.24035622 0.21420808 238.50 1.18918693e+00 -2.28129573e-01 1.21087103e+00 -0.18953395 0.23357293 238.75 1.32337901e+00 -1.86227567e-01 1.33641786e+00 -0.13980327 0.28817132 239.00 1.20732311e+00 -8.10418876e-02 1.21004003e+00 -0.06702472 0.19987199 239.25 1.42641596e+00 1.78120563e-02 1.42652717e+00 0.01248663 0.30744102 239.50 1.50003845e+00 -1.61267788e-01 1.50868242e+00 -0.10709775 0.33270372 239.75 1.75741425e+00 -4.88457551e-01 1.82403279e+00 -0.27109841 0.47509966 240.00 1.55532962e+00 -1.19399621e+00 1.96078484e+00 -0.65472093 0.41995338 240.25 1.66878512e+00 -1.81419017e+00 2.46498068e+00 -0.82712130 0.54291196 240.50 1.23456106e+00 -2.03573197e+00 2.38082877e+00 -1.02565076 0.47858808 240.75 6.86959447e-01 -2.19641091e+00 2.30133313e+00 -1.26767047 0.48006716 241.00 -2.02805961e-01 -2.01787965e+00 2.02804550e+00 -1.67096445 0.39180161 241.25 -7.18549270e-01 -1.93630098e+00 2.06532674e+00 -1.92613799 0.49509247 241.50 -5.68194562e-01 -1.33925575e+00 1.45480274e+00 -1.97204123 0.31885533 241.75 -7.91218745e-01 -7.69436087e-01 1.10365710e+00 -2.37015097 0.24384252 242.00 -6.34219653e-01 -7.34455634e-01 9.70391491e-01 -2.28308924 0.22530840 242.25 -4.71026130e-01 -5.71072186e-01 7.40262830e-01 -2.26048339 0.19064946 242.50 -4.04932585e-01 -4.08951503e-01 5.75509974e-01 -2.35125658 0.12999334 242.75 -4.95587896e-01 -2.82811830e-01 5.70604849e-01 -2.62302666 0.17161505 243.00 -7.13756461e-01 2.09327207e-01 7.43818637e-01 2.85631658 0.24947861 243.25 -6.70945227e-01 5.11538990e-01 8.43705894e-01 2.49019291 0.27737512 243.50 -5.29616741e-01 4.71463155e-01 7.09063748e-01 2.41422013 0.08878549 243.75 -6.63334485e-01 1.90933216e-01 6.90266710e-01 2.86133018 0.05287806 244.00 1.29056024e-01 -4.06200706e-01 4.26209421e-01 -1.26316758 0.01440360 244.25 4.80793724e-01 -5.71003847e-01 7.46463662e-01 -0.87095635 0.05299943 244.50 9.76681951e-01 -9.10054668e-01 1.33495585e+00 -0.75009933 0.16400626 244.75 1.10146145e+00 -7.39851889e-01 1.32687533e+00 -0.59147928 0.17504504 245.00 7.75120579e-01 -1.18486855e+00 1.41588326e+00 -0.99148630 0.26257047 245.25 7.19211062e-01 -1.09412506e+00 1.30934113e+00 -0.98927918 0.21965279 245.50 1.02264231e+00 -1.14640621e+00 1.53624363e+00 -0.84239544 0.33997032 245.75 9.84040332e-01 -1.38080741e+00 1.69557202e+00 -0.95162698 0.39843670 246.00 4.50014458e-01 -2.27649455e+00 2.32054745e+00 -1.37563379 0.56973890 246.25 1.77781233e-01 -2.41508181e+00 2.42161647e+00 -1.49731594 0.58980599 246.50 9.52177264e-02 -3.07659015e+00 3.07806325e+00 -1.53985709 0.62704145 246.75 -1.83063059e-01 -2.66691010e+00 2.67318565e+00 -1.63933120 0.58261138 247.00 -6.78015600e-01 -2.27667834e+00 2.37549351e+00 -1.86024194 0.61156038 247.25 -9.04236301e-01 -1.96010331e+00 2.15862185e+00 -2.00302460 0.62888586 247.50 -1.15161298e+00 -1.69656250e+00 2.05049671e+00 -2.16714645 0.73986252 247.75 -1.06184450e+00 -1.51803490e+00 1.85255060e+00 -2.18117739 0.61637526 248.00 -1.16483990e+00 -1.18600760e+00 1.66236760e+00 -2.34719045 0.63472454 248.25 -9.67791984e-01 -9.47828151e-01 1.35462154e+00 -2.36661572 0.52923125 248.50 -6.19950880e-01 -7.57492988e-01 9.78843562e-01 -2.25667124 0.45199928 248.75 -4.76736690e-01 -7.25675226e-01 8.68264018e-01 -2.15204599 0.29504427 249.00 -9.93718864e-02 -7.85035673e-01 7.91300057e-01 -1.69670931 0.29301105 249.25 -4.22666243e-02 -7.14838346e-01 7.16086816e-01 -1.62985509 0.17219527 249.50 3.27551389e-01 -4.22510477e-01 5.34607347e-01 -0.91132988 0.08171070 249.75 1.68730222e-01 -7.53354128e-01 7.72018349e-01 -1.35046058 0.05733646 250.00 6.20478080e-01 5.88367729e-02 6.23261433e-01 0.09454221 0.01138882 250.25 1.48661334e-01 -2.35088220e-01 2.78148635e-01 -1.00691905 0.00242580 250.50 -1.34458221e+00 -1.65535684e+00 2.13262927e+00 -2.25296905 0.20166431 250.75 -2.36098256e+00 -1.46066142e+00 2.77628717e+00 -2.58756055 0.39881193 251.00 -2.93772560e+00 -1.24156448e+00 3.18931248e+00 -2.74173300 0.51729099 251.25 -2.44159327e+00 -3.87438978e-01 2.47214211e+00 -2.98422193 0.46429032 251.50 -2.41151380e+00 -2.32299816e-01 2.42267662e+00 -3.04555951 0.60503082 251.75 -2.34947810e+00 -4.90827118e-01 2.40019970e+00 -2.93564561 0.56757336 252.00 -2.55013092e+00 -2.98288418e-01 2.56751703e+00 -3.02515193 0.67901066 252.25 -2.24053464e+00 -4.22772852e-01 2.28007288e+00 -2.95509262 0.63036763 252.50 -2.41928222e+00 -3.07169873e-01 2.43870453e+00 -3.01530104 0.71152236 252.75 -2.79885899e+00 -1.14826678e-01 2.80121346e+00 -3.10058940 0.72904637 253.00 -3.03747606e+00 2.69816046e-01 3.04943626e+00 3.05299616 0.79512493 253.25 -2.93136882e+00 3.27599975e-01 2.94961776e+00 3.03029781 0.76954659 253.50 -3.06541753e+00 6.59644587e-01 3.13558856e+00 2.92963571 0.79994647 253.75 -3.13248709e+00 1.50947343e+00 3.47720942e+00 2.69254829 0.79631857 254.00 -3.03969168e+00 2.07772596e+00 3.68193844e+00 2.54200488 0.77723549 254.25 -1.85742948e+00 2.77874876e+00 3.34237774e+00 2.16002628 0.68696742 254.50 -1.39135785e+00 2.67472834e+00 3.01497071e+00 2.05046249 0.68409839 254.75 -8.14011440e-01 3.25361162e+00 3.35389374e+00 1.81595101 0.69761936 255.00 -5.11230969e-01 3.41894798e+00 3.45695855e+00 1.71922535 0.70090551 255.25 8.77438630e-01 3.17936101e+00 3.29821694e+00 1.30151966 0.63297861 255.50 1.63135777e+00 2.37719278e+00 2.88311875e+00 0.96935564 0.60361582 255.75 2.08568513e+00 1.24531156e+00 2.42917339e+00 0.53826638 0.59134007 256.00 2.01841642e+00 7.10428651e-01 2.13979291e+00 0.33843167 0.60967317 256.25 1.51091607e+00 2.42778475e-01 1.53029695e+00 0.15932111 0.51896509 256.50 1.16654391e+00 -1.90229366e-02 1.16669900e+00 -0.01630564 0.36350569 256.75 9.96219352e-01 -3.77211529e-01 1.06524248e+00 -0.36196074 0.33816330 257.00 7.13966657e-01 -4.38971632e-01 8.38119610e-01 -0.55125618 0.23505067 257.25 7.29306120e-01 -1.87845215e-01 7.53109050e-01 -0.25208780 0.21998267 257.50 5.03973327e-01 -2.52208628e-01 5.63558610e-01 -0.46399989 0.13593002 257.75 3.46280432e-01 -2.72707704e-01 4.40771629e-01 -0.66709353 0.13474203 258.00 2.15589892e-01 -3.83936737e-01 4.40325357e-01 -1.05914819 0.11839115 258.25 2.75048408e-01 -9.86829468e-02 2.92215590e-01 -0.34447861 0.06044347 258.50 1.61134714e-01 -7.34383188e-02 1.77080723e-01 -0.42763136 0.02120747 258.75 6.85494441e-02 3.44972570e-02 7.67403872e-02 0.46624131 0.00545515 259.00 9.54170309e-02 -1.23466736e-01 1.56039881e-01 -0.91285236 0.01713328 259.25 4.33600852e-02 -1.13491808e-01 1.21492747e-01 -1.20585505 0.01635417 259.50 4.20697305e-02 -4.15563239e-02 5.91336645e-02 -0.77925893 0.00311107 259.75 -4.01420165e-02 -6.19022015e-02 7.37784795e-02 -2.14609859 0.00848508 260.00 -2.36032602e-02 -5.20652679e-02 5.71656016e-02 -1.99642419 0.00470510 260.25 -2.37821694e-02 7.33415606e-02 7.71010771e-02 1.88436414 0.00901229 260.50 3.81454148e-02 1.57980183e-01 1.62520186e-01 1.33387419 0.02763091 260.75 8.12186936e-02 1.91235122e-01 2.07767534e-01 1.16917477 0.06593137 261.00 7.96240613e-02 3.07518205e-01 3.17659310e-01 1.31743574 0.09360097 261.25 1.43244372e-01 3.54109653e-01 3.81985074e-01 1.18639964 0.15962448 261.50 3.44174309e-01 5.04676837e-01 6.10863868e-01 0.97227401 0.24713982 261.75 5.17062526e-01 6.19992417e-01 8.07306790e-01 0.87567534 0.42752334 262.00 6.62609561e-01 6.50464957e-01 9.28523608e-01 0.77614944 0.32851607 262.25 7.20307909e-01 7.24723200e-01 1.02179607e+00 0.78845365 0.34759198 262.50 8.61954678e-01 4.60119375e-01 9.77075077e-01 0.49032777 0.26845426 262.75 9.26541478e-01 2.99337412e-01 9.73695022e-01 0.31248496 0.27816607 263.00 2.86608852e-01 5.85115823e-01 6.51540606e-01 1.11531561 0.10010739 263.25 1.50173420e-01 7.85050352e-01 7.99284749e-01 1.38178822 0.14073914 263.50 -7.48957919e-02 8.54627444e-01 8.57902936e-01 1.65820861 0.10347816 263.75 -9.42874187e-02 1.16753055e+00 1.17133160e+00 1.65137943 0.18722662 264.00 -8.94926994e-01 1.52086183e+00 1.76462886e+00 2.10266810 0.39807394 264.25 -9.01970495e-01 2.00078702e+00 2.19469803e+00 1.99432186 0.58473421 264.50 -6.92720660e-01 1.81049133e+00 1.93848930e+00 1.93622616 0.52497064 264.75 -7.84931146e-01 1.37473109e+00 1.58303584e+00 2.08959719 0.40093843 265.00 -7.44920185e-01 7.93730447e-01 1.08853760e+00 2.32448235 0.19168632 265.25 -8.18532889e-01 7.94405735e-01 1.14064743e+00 2.37115188 0.18507243 265.50 -5.51952321e-01 8.17680616e-01 9.86535835e-01 2.16456104 0.17725808 265.75 -6.36687828e-01 1.00451904e+00 1.18929807e+00 2.13571552 0.25421739 266.00 -5.16685329e-02 6.23625433e-01 6.25762190e-01 1.65345940 0.11626491 266.25 -7.91077446e-02 6.25224159e-01 6.30208921e-01 1.69665456 0.13247669 266.50 -1.77250539e-01 3.39258881e-01 3.82771919e-01 2.05225318 0.05704894 266.75 -2.72771963e-01 1.38656064e-01 3.05990274e-01 2.67130941 0.03247821 267.00 -3.77835868e-01 4.81125281e-01 6.11752792e-01 2.23651988 0.10721113 267.25 -2.27366924e-01 3.02935815e-01 3.78768829e-01 2.21464607 0.04603532 267.50 -2.79548822e-01 5.55550230e-01 6.21919289e-01 2.03699483 0.11666204 267.75 -2.66877284e-01 3.87160487e-01 4.70230504e-01 2.17431816 0.06502076 268.00 -1.74208452e-02 -2.08259185e-01 2.08986540e-01 -1.65425186 0.01486054 268.25 -2.93709868e-01 -2.48662245e-01 3.84835548e-01 -2.43906096 0.03451205 268.50 -3.44819735e-01 5.03172937e-01 6.09986602e-01 2.17158191 0.11863387 268.75 -4.17706761e-01 3.11574775e-01 5.21112059e-01 2.50070948 0.09154591 269.00 -5.50032576e-01 1.29232683e-01 5.65010549e-01 2.91082372 0.14353850 269.25 -6.16401038e-01 1.44239689e-01 6.33052390e-01 2.91172573 0.13869690 269.50 -9.00316575e-01 1.93455478e-01 9.20866417e-01 2.92993602 0.26998939 269.75 -7.12471482e-01 3.04369860e-01 7.74762302e-01 2.73785764 0.14775875 270.00 -7.14089620e-01 3.86076382e-01 8.11775190e-01 2.64595213 0.17256824 270.25 -7.11677882e-01 3.32802317e-01 7.85648007e-01 2.70417428 0.13949122 270.50 -7.62220403e-01 2.94431037e-01 8.17110506e-01 2.77296891 0.18520868 270.75 -9.75575694e-01 1.79726541e-01 9.91992724e-01 2.95940924 0.18397570 271.00 -1.33941221e+00 1.39902371e-01 1.34669883e+00 3.03751946 0.29419982 271.25 -1.19991769e+00 2.18153756e-01 1.21958744e+00 2.96174972 0.16605173 271.50 -1.25432228e+00 3.49649578e-01 1.30214409e+00 2.86973809 0.20701462 271.75 -1.28929264e+00 4.04505645e-01 1.35125880e+00 2.83757641 0.15452016 272.00 -1.59847387e+00 3.77948861e-01 1.64254804e+00 2.90941312 0.21925160 272.25 -1.36376086e+00 4.10779713e-01 1.42428356e+00 2.84902526 0.11289389 272.50 -1.71436922e+00 7.15371439e-01 1.85763778e+00 2.74627932 0.18739265 272.75 -1.55737735e+00 9.36465329e-02 1.56019033e+00 3.08153405 0.14689079 273.00 -1.52519096e+00 -1.69289796e-01 1.53455743e+00 -3.03104934 0.12763724 273.25 -1.41626503e+00 -4.25240611e-01 1.47872790e+00 -2.84990196 0.08857665 273.50 -1.48245461e+00 -3.88956441e-01 1.53263133e+00 -2.88500290 0.08498552 273.75 -1.38749087e+00 -1.53399496e+00 2.06839828e+00 -2.30608934 0.19896052 274.00 -1.45755935e+00 -1.72773703e+00 2.26043237e+00 -2.27157676 0.24933024 274.25 -6.68495560e-01 -2.01715320e+00 2.12503961e+00 -1.89081078 0.24254365 274.50 -5.26504981e-01 -2.05745631e+00 2.12375468e+00 -1.82132105 0.23516779 274.75 -2.33684877e-01 -1.70550137e+00 1.72143647e+00 -1.70696668 0.22761294 275.00 -3.13633765e-01 -1.50471283e+00 1.53705134e+00 -1.77628848 0.24831779 275.25 -3.44996623e-01 -1.09677903e+00 1.14975950e+00 -1.87555169 0.19786221 275.50 -2.28215762e-01 -1.03869919e+00 1.06347471e+00 -1.78707291 0.22921443 275.75 -1.18603386e-01 -1.07677855e+00 1.08329073e+00 -1.68050060 0.25502125 276.00 -1.48505870e-01 -1.13251068e+00 1.14220595e+00 -1.70118217 0.25630012 276.25 -7.61876732e-02 -8.01213643e-01 8.04827847e-01 -1.66560160 0.16143872 276.50 3.52834431e-02 -5.65463612e-01 5.66563340e-01 -1.50847975 0.12857891 276.75 -1.07161174e-01 -4.54644602e-01 4.67103020e-01 -1.80227455 0.14606391 277.00 -6.37819262e-02 -6.08386820e-01 6.11721061e-01 -1.67525253 0.21769702 277.25 -2.28453289e-01 -2.81840194e-01 3.62801323e-01 -2.25195370 0.08857433 277.50 -1.31893185e-01 -3.02012439e-01 3.29556255e-01 -1.98254720 0.06069232 277.75 -3.43085218e-01 -2.55504110e-01 4.27773091e-01 -2.50147616 0.11850674 278.00 -2.78591687e-01 -2.47496120e-01 3.72649510e-01 -2.41523298 0.09197108 278.25 -1.75106645e-01 -1.40833578e-01 2.24714116e-01 -2.46425154 0.05530026 278.50 -1.79285606e-01 -1.45021891e-01 2.30596351e-01 -2.46145593 0.04891641 278.75 -1.35517935e-01 -1.63503436e-01 2.12364037e-01 -2.26287602 0.05411768 279.00 -1.74074063e-01 -6.44325406e-02 1.85616087e-01 -2.78708572 0.03841721 279.25 -1.45702052e-01 1.08759346e-03 1.45706111e-01 3.13412829 0.03474428 279.50 -7.47881481e-02 -8.14181174e-02 1.10553955e-01 -2.31377627 0.01529524 279.75 -1.15768841e-02 -1.19050377e-01 1.19611941e-01 -1.66773511 0.02524431 280.00 -4.22673257e-02 -1.35967880e-01 1.42386064e-01 -1.87218876 0.02692982 280.25 -1.70902800e-01 -1.64982364e-01 2.37543569e-01 -2.37381903 0.09130691 280.50 -2.33958227e-01 -1.33957486e-01 2.69594251e-01 -2.62158642 0.07374642 280.75 -2.31061962e-01 -1.17748783e-01 2.59334545e-01 -2.67029592 0.06686387 281.00 -3.28399212e-01 3.11591311e-03 3.28413993e-01 3.13210475 0.06981258 281.25 -4.86002999e-01 1.43835133e-01 5.06840666e-01 2.85385077 0.15190772 281.50 -3.07492052e-01 1.97806169e-01 3.65620900e-01 2.56994986 0.06548692 281.75 -1.21803572e-01 2.03211127e-01 2.36919548e-01 2.11077027 0.03453399 282.00 -1.11137720e-03 2.94532515e-01 2.94534612e-01 1.57456967 0.03700838 282.25 1.71339223e-01 3.65516867e-01 4.03682684e-01 1.13245261 0.10043454 282.50 1.57311305e-01 4.15257296e-01 4.44055705e-01 1.20867338 0.14826090 282.75 1.77301340e-01 4.46756235e-01 4.80652576e-01 1.19299656 0.25167294 283.00 3.71744227e-01 3.11176603e-01 4.84793408e-01 0.69694052 0.24070740 283.25 4.77463118e-01 2.43849719e-01 5.36128449e-01 0.47218638 0.39376830 283.50 4.10008432e-01 2.34573303e-01 4.72368023e-01 0.51966586 0.30036393 283.75 4.05984465e-01 1.99601025e-01 4.52398005e-01 0.45694287 0.32580530 284.00 5.50544006e-01 1.30007922e-01 5.65686099e-01 0.23189626 0.34694370 284.25 6.13420108e-01 1.09027375e-01 6.23033865e-01 0.17589998 0.48088852 284.50 5.55326194e-01 -3.25005457e-02 5.56276431e-01 -0.05845846 0.39783367 284.75 4.75724631e-01 -1.77412838e-01 5.07729494e-01 -0.35695621 0.39310261 285.00 3.17148035e-01 -1.88377766e-01 3.68875397e-01 -0.53597702 0.21706425 285.25 2.00101534e-01 -2.30408569e-01 3.05170006e-01 -0.85568018 0.18815917 285.50 3.13000137e-01 -2.73995409e-01 4.15983858e-01 -0.71904762 0.38510064 285.75 3.02466330e-01 -2.76299014e-01 4.09666969e-01 -0.74021663 0.40835282 286.00 1.64942071e-01 -3.33102636e-01 3.71703178e-01 -1.11102105 0.37638576 286.25 1.01998256e-01 -3.47974750e-01 3.62615596e-01 -1.28566362 0.38217034 286.50 -9.47330921e-02 -3.16631379e-01 3.30499302e-01 -1.86151027 0.28982057 286.75 -9.13917417e-02 -3.23910700e-01 3.36556967e-01 -1.84579857 0.30109856 287.00 -2.70938296e-01 -1.28862443e-01 3.00021815e-01 -2.69764228 0.20346101 287.25 -2.71622104e-01 -6.55267758e-02 2.79414255e-01 -2.90487324 0.18785494 287.50 -3.79566850e-01 1.83546754e-02 3.80010379e-01 3.09327340 0.30288539 287.75 -2.63076478e-01 2.28628799e-01 3.48540329e-01 2.42613779 0.25452053 288.00 -1.97147082e-02 3.06567136e-01 3.07200388e-01 1.63501586 0.21493153 288.25 7.82586548e-02 2.43472388e-01 2.55740535e-01 1.25979926 0.15297701 288.50 2.43747692e-01 2.02773369e-01 3.17064625e-01 0.69389096 0.26850800 288.75 2.67839351e-01 1.27590418e-01 2.96676984e-01 0.44456489 0.21358630 289.00 2.07743462e-01 -1.97043770e-02 2.08675845e-01 -0.09456665 0.11901278 289.25 2.20677748e-01 -4.01620701e-02 2.24302609e-01 -0.18002388 0.12237132 289.50 2.77282118e-01 -1.07898131e-01 2.97535510e-01 -0.37109864 0.24788176 289.75 2.23301856e-01 -1.31140236e-01 2.58962314e-01 -0.53101246 0.14213650 290.00 1.49963038e-01 -1.66801899e-01 2.24302890e-01 -0.83850703 0.14861389 290.25 1.80745098e-01 -1.99529867e-01 2.69222879e-01 -0.83475590 0.17972341 290.50 1.85399394e-01 -2.40201827e-01 3.03430145e-01 -0.91345825 0.34706655 290.75 1.62664289e-01 -2.48966118e-01 2.97395022e-01 -0.99206330 0.21692847 291.00 1.11149319e-01 -3.96033587e-01 4.11335354e-01 -1.29717915 0.35023377 291.25 1.21824247e-01 -3.51300355e-01 3.71824000e-01 -1.23699219 0.33317742 291.50 1.53480628e-01 -3.14049216e-01 3.49547155e-01 -1.11621724 0.38652316 291.75 1.08645506e-01 -3.17925302e-01 3.35976701e-01 -1.24150539 0.32139376 292.00 6.35363446e-02 -3.29102532e-01 3.35179570e-01 -1.38008322 0.34224036 292.25 6.73520669e-02 -3.56031222e-01 3.62345873e-01 -1.38383113 0.23964866 292.50 8.83530717e-02 -3.77002850e-01 3.87217528e-01 -1.34059427 0.32723793 292.75 9.71298954e-02 -5.14759667e-01 5.23843232e-01 -1.38429924 0.37237619 293.00 2.67758736e-02 -6.58783555e-01 6.59327475e-01 -1.53017427 0.47999509 293.25 -3.59167003e-02 -8.91486762e-01 8.92209984e-01 -1.61106309 0.46009379 293.50 -3.02190652e-01 -1.08357115e+00 1.12492028e+00 -1.84276986 0.60526251 293.75 -5.56880035e-01 -1.20024283e+00 1.32313953e+00 -2.00520909 0.65977087 294.00 -6.77537023e-01 -1.29852520e+00 1.46465836e+00 -2.05171122 0.72692221 294.25 -1.28138913e+00 -1.10970203e+00 1.69510964e+00 -2.42787430 0.76711385 294.50 -1.56492604e+00 -9.85995996e-01 1.84964365e+00 -2.57936356 0.81818470 294.75 -1.86883255e+00 -5.02316177e-01 1.93516321e+00 -2.87901260 0.71918434 295.00 -2.06323724e+00 3.74981069e-02 2.06357797e+00 3.12342025 0.77266398 295.25 -1.82816694e+00 6.35530792e-01 1.93548282e+00 2.80702825 0.80386768 295.50 -1.62843333e+00 8.11482096e-01 1.81942252e+00 2.67928936 0.81473261 295.75 -1.15773090e+00 1.05034446e+00 1.56319043e+00 2.40478970 0.65954970 296.00 -7.72271619e-01 1.12859614e+00 1.36752795e+00 2.17089136 0.58670960 296.25 -4.83191105e-01 8.51321811e-01 9.78888385e-01 2.08703451 0.56726550 296.50 -3.14106517e-01 8.33976494e-01 8.91167602e-01 1.93100152 0.55548284 296.75 -2.13526478e-01 5.14434994e-01 5.56989156e-01 1.96422611 0.45022799 297.00 -1.78701802e-01 4.17012964e-01 4.53689482e-01 1.97565157 0.41590404 297.25 -2.48650022e-01 4.42931125e-01 5.07951587e-01 2.08233002 0.50980310 297.50 -2.61562875e-01 3.45898324e-01 4.33659761e-01 2.21824364 0.42630814 297.75 -2.34066770e-01 2.84399895e-01 3.68334839e-01 2.25941703 0.42807544 298.00 -2.51591564e-01 2.17457116e-01 3.32544602e-01 2.42884021 0.39876675 298.25 -3.40867221e-01 2.69569508e-01 4.34578166e-01 2.47246556 0.65054164 298.50 -3.54749165e-01 2.31888320e-01 4.23815011e-01 2.56264291 0.56464778 298.75 -3.53555206e-01 1.70356131e-01 3.92456998e-01 2.69258039 0.61491582 299.00 -3.53982003e-01 1.29037083e-01 3.76767604e-01 2.79203255 0.59672147 299.25 -3.82880097e-01 7.70859512e-02 3.90562943e-01 2.94291682 0.68051984 299.50 -3.98700562e-01 5.14543930e-02 4.02007080e-01 3.01324683 0.64583380 299.75 -3.67987623e-01 -1.57575231e-02 3.68324843e-01 -3.09879800 0.62461537 300.00 -3.93537177e-01 -3.94909057e-02 3.95513643e-01 -3.04157886 0.53228012 300.25 -4.62913920e-01 -1.46319845e-02 4.63145109e-01 -3.10999474 0.61425508 300.50 -4.65168192e-01 -2.38963806e-02 4.65781584e-01 -3.09026629 0.56048409 300.75 -4.17632693e-01 -3.94698556e-02 4.19493666e-01 -3.04736400 0.51606450 301.00 -4.77053983e-01 -4.17291166e-02 4.78875581e-01 -3.05434221 0.61038723 301.25 -4.77690900e-01 -9.07520118e-02 4.86235050e-01 -2.95384942 0.70021425 301.50 -4.78782809e-01 -1.08217324e-01 4.90860436e-01 -2.91930194 0.57356120 301.75 -4.48425995e-01 -8.09652314e-02 4.55676685e-01 -2.96296289 0.61260231 302.00 -3.87369496e-01 -2.04899591e-01 4.38222511e-01 -2.65505317 0.50548733 302.25 -3.38679172e-01 -3.59473477e-01 4.93887398e-01 -2.32641854 0.65447556 302.50 -4.05537012e-01 -3.07479791e-01 5.08924444e-01 -2.49286162 0.64407096 302.75 -4.29026999e-01 -2.78096833e-01 5.11274891e-01 -2.56648134 0.69739893 303.00 -3.97261486e-01 -3.48089656e-01 5.28188505e-01 -2.42207039 0.53613372 303.25 -4.23638970e-01 -4.41129608e-01 6.11608787e-01 -2.33597145 0.58696102 303.50 -4.55445192e-01 -4.63771397e-01 6.50010947e-01 -2.34713680 0.56786360 303.75 -4.40777902e-01 -5.54512967e-01 7.08357105e-01 -2.24241484 0.74389793 304.00 -3.68556847e-01 -5.86200565e-01 6.92434294e-01 -2.13206724 0.68073595 304.25 -3.43939921e-01 -6.57714287e-01 7.42214762e-01 -2.05262087 0.76671355 304.50 -3.87408498e-01 -6.47706548e-01 7.54724530e-01 -2.10983489 0.67545044 304.75 -4.26564098e-01 -6.64107262e-01 7.89300567e-01 -2.14174801 0.69139658 305.00 -3.82521507e-01 -8.11690430e-01 8.97309343e-01 -2.01119305 0.74807522 305.25 -3.89774657e-01 -8.55730466e-01 9.40318517e-01 -1.99820440 0.80760634 305.50 -2.44728126e-01 -8.68251292e-01 9.02082126e-01 -1.84553198 0.77293301 305.75 -1.54161013e-01 -9.15459253e-01 9.28348675e-01 -1.73762854 0.78587729 306.00 -1.40579366e-01 -9.69508139e-01 9.79647176e-01 -1.71479344 0.80462864 306.25 -1.80440028e-01 -1.05835455e+00 1.07362608e+00 -1.73966375 0.85083232 306.50 -5.51453789e-02 -1.26342473e+00 1.26462764e+00 -1.61441618 0.83229010 306.75 -2.85425484e-02 -1.27602247e+00 1.27634166e+00 -1.59316097 0.81497913 307.00 2.23007272e-01 -1.32275446e+00 1.34142148e+00 -1.40377387 0.75969530 307.25 2.56313723e-01 -1.41134857e+00 1.43443421e+00 -1.39114524 0.79862747 307.50 2.92908598e-01 -1.40171834e+00 1.43199503e+00 -1.36479663 0.73404431 307.75 4.93503431e-01 -1.56872932e+00 1.64452344e+00 -1.26601035 0.68676901 308.00 1.24098731e+00 -1.31211623e+00 1.80601730e+00 -0.81325075 0.42332051 308.25 1.67230541e+00 -8.13437802e-01 1.85964686e+00 -0.45272229 0.30596104 308.50 -1.08910703e+00 6.99194180e-01 1.29422820e+00 2.57087006 0.09427155 308.75 -1.38811502e+00 1.04960957e+00 1.74027111e+00 2.49417339 0.23152681 309.00 -8.83776745e-01 9.27776432e-01 1.28133932e+00 2.33191089 0.30228728 309.25 -9.02333719e-01 7.13525518e-01 1.15035855e+00 2.47251396 0.37747103 309.50 -4.41668789e-01 4.89295243e-01 6.59151845e-01 2.30508084 0.34771235 309.75 -1.27710273e-01 2.83567832e-01 3.10999404e-01 1.99395740 0.08496736 310.00 2.47151338e-01 -3.38043933e-01 4.18757071e-01 -0.93948705 0.19870786 310.25 3.76667125e-01 -6.53995500e-01 7.54710697e-01 -1.04825021 0.41359984 310.50 4.32035660e-01 -1.08164606e+00 1.16473732e+00 -1.19078639 0.71043325 310.75 3.96132259e-01 -1.25835394e+00 1.31923288e+00 -1.26581570 0.73698984 311.00 2.89678685e-01 -1.36437603e+00 1.39478877e+00 -1.36158711 0.82034423 311.25 2.66695850e-01 -1.47142676e+00 1.49540074e+00 -1.39149305 0.83209825 311.50 1.66481629e-01 -1.59750568e+00 1.60615707e+00 -1.46695767 0.90163159 311.75 1.76621423e-01 -1.74178022e+00 1.75071227e+00 -1.46973894 0.91517986 312.00 1.12035123e-01 -1.85107902e+00 1.85446634e+00 -1.51034584 0.92559396 312.25 5.57482109e-02 -1.92524985e+00 1.92605681e+00 -1.54184806 0.88038416 312.50 -9.47882071e-02 -1.90627014e+00 1.90862533e+00 -1.62047984 0.91945269 312.75 -1.43593132e-01 -2.03694132e+00 2.04199631e+00 -1.64117439 0.94080642 313.00 -9.82294699e-02 -2.04395068e+00 2.04630971e+00 -1.61881801 0.96023966 313.25 -3.44856650e-02 -2.07846905e+00 2.07875512e+00 -1.58738666 0.96065618 313.50 4.99854906e-02 -2.18297909e+00 2.18355129e+00 -1.54790249 0.96649038 313.75 4.12326818e-02 -2.48629025e+00 2.48663213e+00 -1.55421383 0.95982903 314.00 7.64260985e-02 -2.71477822e+00 2.71585378e+00 -1.54265188 0.96898874 314.25 9.59337828e-02 -3.12535527e+00 3.12682728e+00 -1.54011064 0.93992799 314.50 8.97253759e-02 -3.51329631e+00 3.51444186e+00 -1.54526308 0.90789794 314.75 -5.75118235e-01 -3.62432764e+00 3.66967462e+00 -1.72816694 0.67184273 315.00 -2.66363314e+00 -3.52630365e+00 4.41924868e+00 -2.21771982 0.56558860 315.25 -4.44255233e+00 -1.46471084e+00 4.67778249e+00 -2.82311538 0.67411430 315.50 -4.44018657e+00 -2.35683549e-01 4.44643717e+00 -3.08856277 0.78594249 315.75 -3.52782612e+00 5.93195936e-01 3.57735078e+00 2.97500329 0.81547795 316.00 -2.84421381e+00 7.43347312e-01 2.93974785e+00 2.88595653 0.83046371 316.25 -2.21910631e+00 1.15774093e+00 2.50295763e+00 2.66072438 0.90537342 316.50 -1.90908399e+00 1.22861766e+00 2.27026497e+00 2.56975520 0.89298561 316.75 -1.07273742e+00 1.12815631e+00 1.55676018e+00 2.33101963 0.86594417 317.00 -7.62392833e-01 9.79544673e-01 1.24126975e+00 2.23217320 0.85996937 317.25 -4.43731302e-01 6.82606636e-01 8.14155567e-01 2.14720964 0.82875784 317.50 -3.82622862e-01 5.55917079e-01 6.74865953e-01 2.17360856 0.79010271 317.75 -3.33923602e-01 2.60250413e-01 4.23361842e-01 2.47955747 0.58394166 318.00 -2.95505818e-01 2.02215255e-01 3.58070800e-01 2.54148006 0.49812090 318.25 -2.62225838e-01 9.37418191e-02 2.78477861e-01 2.79826526 0.40679964 318.50 -2.22698429e-01 4.29173046e-02 2.26796132e-01 2.95121171 0.27930116 318.75 -2.48592210e-01 -5.39162940e-02 2.54371881e-01 -2.92801405 0.39169598 319.00 -2.31931738e-01 -5.26141212e-02 2.37824676e-01 -2.91851639 0.33502418 319.25 -1.33389187e-01 -3.87642558e-02 1.38907677e-01 -2.85877248 0.15521029 319.50 -1.25505524e-01 -1.22339756e-01 1.75267374e-01 -2.36896696 0.17952487 319.75 -1.76791695e-01 -9.68951742e-02 2.01603517e-01 -2.64022828 0.22493678 320.00 -1.61391033e-01 -1.11720687e-01 1.96286977e-01 -2.53609644 0.19660559 320.25 -1.26612870e-01 -7.74334012e-02 1.48414118e-01 -2.59270479 0.13268148 320.50 -1.27727164e-01 -1.06881104e-01 1.66546687e-01 -2.44481650 0.12077792 320.75 -1.18700229e-01 -1.51256335e-01 1.92271223e-01 -2.23617652 0.15827081 321.00 -1.52865380e-01 -7.21279214e-02 1.69027398e-01 -2.70072617 0.13792728 321.25 -1.68633301e-01 5.90479312e-02 1.78672461e-01 2.80477903 0.28260810 321.50 -1.20123588e-01 7.59964008e-02 1.42144748e-01 2.57750985 0.16051722 321.75 -4.56511016e-02 9.56327100e-02 1.05969988e-01 2.01616735 0.12040386 322.00 1.98587249e-02 1.16266025e-01 1.17949809e-01 1.40162467 0.10853802 322.25 1.46507370e-01 1.06734582e-01 1.81264118e-01 0.62961619 0.20971966 322.50 2.29331145e-01 9.31379454e-02 2.47522627e-01 0.38577849 0.29482680 322.75 3.14915466e-01 9.22900293e-02 3.28160327e-01 0.28508036 0.53551223 323.00 3.57181622e-01 1.02138311e-01 3.71498244e-01 0.27852333 0.44384170 323.25 4.30033510e-01 6.45542662e-02 4.34851783e-01 0.14900193 0.54975811 323.50 4.98290698e-01 1.16494870e-01 5.11727148e-01 0.22966400 0.59529516 323.75 5.81590474e-01 1.35877764e-01 5.97252246e-01 0.22951454 0.73411938 324.00 6.07824163e-01 4.28766735e-02 6.09334574e-01 0.07042459 0.59006623 324.25 6.86598807e-01 9.35885575e-03 6.86662589e-01 0.01362990 0.70558494 324.50 8.26277691e-01 4.46531076e-02 8.27483367e-01 0.05398877 0.73737464 324.75 1.01553636e+00 6.27715121e-02 1.01747450e+00 0.06173265 0.83334443 325.00 1.15429316e+00 -5.89461795e-03 1.15430821e+00 -0.00510665 0.85320105 325.25 1.24040318e+00 -4.70245021e-02 1.24129422e+00 -0.03789251 0.86601371 325.50 1.58381524e+00 -2.45557828e-01 1.60273808e+00 -0.15381728 0.77391207 325.75 2.02838198e+00 -4.34289444e-01 2.07435310e+00 -0.21092183 0.86319939 326.00 2.70980939e+00 -1.15259629e+00 2.94474874e+00 -0.40216046 0.90208303 326.25 2.87567785e+00 -1.64241787e+00 3.31165510e+00 -0.51892939 0.90763509 326.50 2.41851220e+00 -3.24608303e+00 4.04799411e+00 -0.93046718 0.82122766 326.75 1.59973747e+00 -4.26395443e+00 4.55417033e+00 -1.21187052 0.83432526 327.00 -1.11006531e+00 -4.42563014e+00 4.56272365e+00 -1.81655272 0.80374548 327.25 -2.02514860e+00 -3.76143200e+00 4.27195477e+00 -2.06468867 0.84576825 327.50 -2.35466898e+00 -2.50455103e+00 3.43762154e+00 -2.32535939 0.80848763 327.75 -2.35403166e+00 -1.77654538e+00 2.94916574e+00 -2.49510178 0.80134048 328.00 -2.30499423e+00 -1.03656941e+00 2.52734536e+00 -2.71898336 0.82045815 328.25 -2.16315228e+00 -7.11509825e-01 2.27716359e+00 -2.82381693 0.81149688 328.50 -1.86677124e+00 -3.44207141e-01 1.89823956e+00 -2.95925429 0.78941320 328.75 -1.64698283e+00 -2.62580545e-01 1.66778325e+00 -2.98349199 0.78848501 329.00 -1.39381808e+00 -1.92530842e-01 1.40705259e+00 -3.00432930 0.74166640 329.25 -1.37002024e+00 -6.61884149e-02 1.37161815e+00 -3.09331819 0.74351190 329.50 -1.13763719e+00 1.34429787e-01 1.14555215e+00 3.02397230 0.75942138 329.75 -1.05362210e+00 1.58723990e-01 1.06551060e+00 2.99207095 0.75521959 330.00 -9.13179462e-01 1.89671902e-01 9.32669374e-01 2.93679958 0.78009076 330.25 -8.71140604e-01 1.95089267e-01 8.92718194e-01 2.92128076 0.75703438 330.50 -7.64575120e-01 2.20851511e-01 7.95833214e-01 2.86039153 0.76540777 330.75 -7.04440271e-01 2.10202741e-01 7.35133517e-01 2.85160731 0.69862989 331.00 -5.32405325e-01 1.82615118e-01 5.62853188e-01 2.81116732 0.62496304 331.25 -4.86670688e-01 1.29647523e-01 5.03643563e-01 2.88124221 0.50719425 331.50 -5.28848873e-01 1.08890303e-02 5.28960964e-01 3.12100550 0.58065715 331.75 -5.52387363e-01 -4.43759692e-02 5.54166965e-01 -3.06142993 0.54507645 332.00 -5.53567845e-01 -1.34205776e-01 5.69603853e-01 -2.90374391 0.66608287 332.25 -6.46704364e-01 -8.92070543e-02 6.52828027e-01 -3.00451669 0.70986257 332.50 -7.49333040e-01 2.08315306e-02 7.49622543e-01 3.11379972 0.82485898 332.75 -7.57433438e-01 5.04363548e-02 7.59110822e-01 3.07510231 0.76285048 333.00 -8.04917323e-01 4.00455939e-02 8.05912865e-01 3.09188245 0.79134543 333.25 -8.86414835e-01 6.11407162e-02 8.88520932e-01 3.07272644 0.78938086 333.50 -9.24328456e-01 2.77744010e-02 9.24745647e-01 3.11155350 0.83897612 333.75 -1.02113283e+00 7.56099980e-02 1.02392828e+00 3.06768232 0.81548596 334.00 -1.15790436e+00 9.73791511e-02 1.16199191e+00 3.05769061 0.89835673 334.25 -1.37253358e+00 2.88316530e-01 1.40248881e+00 2.93454151 0.90399398 334.50 -1.49716549e+00 4.52799915e-01 1.56413947e+00 2.84790056 0.95809171 334.75 -1.53088805e+00 5.90351780e-01 1.64077221e+00 2.77353786 0.95147500 335.00 -1.60989771e+00 7.70647116e-01 1.78484386e+00 2.69513530 0.96304360 335.25 -1.74662990e+00 1.00445149e+00 2.01485453e+00 2.61969844 0.95974664 335.50 -1.79088656e+00 1.28068926e+00 2.20169018e+00 2.52079448 0.96622239 335.75 -1.59210479e+00 1.82397796e+00 2.42109340e+00 2.28842153 0.96226885 336.00 -1.42456846e+00 2.09372133e+00 2.53240287e+00 2.16824661 0.97459741 336.25 -9.20652295e-01 2.24491888e+00 2.42636795e+00 1.95998338 0.95660808 336.50 -6.08998491e-01 2.21232099e+00 2.29461181e+00 1.83941895 0.97469615 336.75 -2.54705636e-01 1.98410776e+00 2.00038961e+00 1.69847092 0.94399174 337.00 -1.60300936e-01 1.77312814e+00 1.78035946e+00 1.66095695 0.95881888 337.25 -2.86728148e-01 1.57316390e+00 1.59908026e+00 1.75107950 0.96974549 337.50 -3.30652596e-01 1.56073122e+00 1.59537240e+00 1.77956689 0.97641851 337.75 -3.80901363e-01 1.59334977e+00 1.63824581e+00 1.80544944 0.98210853 338.00 -3.88109519e-01 1.60384385e+00 1.65013457e+00 1.80821933 0.98551934 338.25 -3.94804424e-01 1.61175048e+00 1.65940054e+00 1.81102003 0.98612131 338.50 -3.83443254e-01 1.62113003e+00 1.66586053e+00 1.80305618 0.98539417 338.75 -4.26373981e-01 1.67180236e+00 1.72531676e+00 1.82051146 0.98339643 339.00 -4.29295769e-01 1.70740114e+00 1.76054352e+00 1.81712257 0.98756679 339.25 -3.59270915e-01 1.72337279e+00 1.76042306e+00 1.77632235 0.99066723 339.50 -3.66318288e-01 1.73543282e+00 1.77367307e+00 1.77882441 0.98734792 339.75 -3.72468500e-01 1.69311601e+00 1.73360163e+00 1.78733704 0.98030387 340.00 -4.00483341e-01 1.66550066e+00 1.71297384e+00 1.80677454 0.97371818 340.25 -4.85904693e-01 1.60438403e+00 1.67635065e+00 1.86487544 0.96411832 340.50 -5.25627571e-01 1.58768074e+00 1.67242772e+00 1.89050516 0.95185309 340.75 -5.49292870e-01 1.64577392e+00 1.73502002e+00 1.89293049 0.95754903 341.00 -5.41333930e-01 1.66700858e+00 1.75270078e+00 1.88478738 0.93677541 341.25 -7.03665720e-01 1.51794692e+00 1.67311335e+00 2.00487274 0.86290373 341.50 -7.52499883e-01 1.49151343e+00 1.67058924e+00 2.03805421 0.82352820 341.75 -8.69645940e-01 1.40612985e+00 1.65332550e+00 2.12468449 0.84595859 342.00 -1.06024494e+00 1.40540693e+00 1.76047947e+00 2.21711019 0.79836853 342.25 -1.50224736e+00 1.36159969e+00 2.02748634e+00 2.40526651 0.84665128 342.50 -1.53500094e+00 1.42824374e+00 2.09668979e+00 2.39220604 0.79206298 342.75 -1.44690958e+00 1.48377133e+00 2.07246826e+00 2.34361728 0.82768546 343.00 -1.67663490e+00 1.44195251e+00 2.21140943e+00 2.43130570 0.77721574 343.25 -1.98698130e+00 1.57901607e+00 2.53798866e+00 2.47010350 0.81270853 343.50 -2.09902636e+00 1.43608106e+00 2.54327357e+00 2.54157323 0.83265916 343.75 -2.17948801e+00 1.29016543e+00 2.53272478e+00 2.60710735 0.91057224 344.00 -2.27307136e+00 1.31552033e+00 2.62629913e+00 2.61695122 0.86169209 344.25 -2.34831479e+00 1.39058421e+00 2.72915863e+00 2.60695587 0.85703253 344.50 -2.53004922e+00 1.14709363e+00 2.77794400e+00 2.71592495 0.80622188 344.75 -2.50085831e+00 8.72631550e-01 2.64873142e+00 2.80586887 0.85590680 345.00 -2.60335455e+00 4.89892036e-01 2.64904683e+00 2.95559056 0.81294142 345.25 -2.47247029e+00 1.74499306e-01 2.47862045e+00 3.07113258 0.81075932 345.50 -1.77857382e+00 -3.38529002e-01 1.81050455e+00 -2.95350515 0.39526420 345.75 -8.88787917e-01 -9.53623860e-01 1.30358829e+00 -2.32101821 0.13742993 346.00 -3.26399332e+00 -1.41744364e+00 3.55848266e+00 -2.73189928 0.20059430 346.25 -6.14182368e+00 -2.26224153e+00 6.54520701e+00 -2.78867905 0.42995924 346.50 -5.09883070e+00 -2.61815269e+00 5.73173604e+00 -2.66721850 0.33504014 346.75 -4.55332561e+00 -2.70396165e+00 5.29567585e+00 -2.60571248 0.24724886 347.00 -2.14393502e+00 -1.92778543e+00 2.88319511e+00 -2.40923027 0.08870368 347.25 -1.71581661e+00 -1.13727859e+00 2.05850170e+00 -2.55625744 0.05632471 347.50 -1.67725168e+00 -5.56510079e-01 1.76716628e+00 -2.82122382 0.06054710 347.75 -9.60971038e-01 -7.15948701e-01 1.19835215e+00 -2.50128232 0.04538664 348.00 7.99819943e-01 -2.26460244e+00 2.40169444e+00 -1.23128835 0.14141410 348.25 1.16435492e+00 -3.62061507e+00 3.80323229e+00 -1.25965141 0.36302226 348.50 1.67405117e+00 -4.92547112e+00 5.20218349e+00 -1.24316866 0.63940195 348.75 1.96334521e+00 -6.14868594e+00 6.45453819e+00 -1.26171819 0.69895763 349.00 3.02546666e+00 -9.08614148e+00 9.57660773e+00 -1.24936745 0.83770013 349.25 3.62584257e+00 -1.00303935e+01 1.06656237e+01 -1.22392623 0.83022457 349.50 5.42565346e+00 -1.32299756e+01 1.42992997e+01 -1.18161087 0.85483028 349.75 6.28205150e+00 -1.47324602e+01 1.60159157e+01 -1.16773297 0.86171443 350.00 5.29294828e+00 -1.83053945e+01 1.90552557e+01 -1.28932599 0.87421344 350.25 3.93210439e+00 -1.97587806e+01 2.01462367e+01 -1.37435728 0.84996222 350.50 3.46497691e+00 -2.43694329e+01 2.46145348e+01 -1.42955767 0.86982483 350.75 1.80230839e+00 -2.75908050e+01 2.76496083e+01 -1.50556621 0.88347548 351.00 -1.30202584e+00 -2.95600538e+01 2.95887150e+01 -1.61481468 0.91997370 351.25 -5.17057847e+00 -2.96729442e+01 3.01200681e+01 -1.74331641 0.92965491 351.50 -8.12270747e+00 -2.96945935e+01 3.07855041e+01 -1.83780620 0.96467968 351.75 -1.09109193e+01 -2.99170782e+01 3.18446185e+01 -1.92051117 0.95256413 352.00 -1.68409203e+01 -3.05409425e+01 3.48764356e+01 -2.07472994 0.96111096 352.25 -1.96420156e+01 -2.78470891e+01 3.40773993e+01 -2.18510559 0.95025876 352.50 -2.67496184e+01 -2.39413770e+01 3.58989083e+01 -2.41153714 0.95472253 352.75 -2.90902187e+01 -1.92916816e+01 3.49057274e+01 -2.55601661 0.94562179 353.00 -2.87096249e+01 -1.28827568e+01 3.14675704e+01 -2.71979864 0.94555768 353.25 -2.68725069e+01 -8.55260058e+00 2.82006844e+01 -2.83346359 0.93274034 353.50 -2.47748463e+01 -4.04189827e+00 2.51023894e+01 -2.97987217 0.95499523 353.75 -2.05771091e+01 -1.14334013e+00 2.06088487e+01 -3.08608604 0.92993764 354.00 -1.69130086e+01 1.81012831e-01 1.69139772e+01 3.13089048 0.95794483 354.25 -1.49082817e+01 9.83302317e-02 1.49086060e+01 3.13499707 0.95528456 354.50 -1.29244548e+01 3.00440359e-01 1.29279464e+01 3.11835096 0.97113970 354.75 -1.16659512e+01 -1.34910414e-01 1.16667312e+01 -3.13002871 0.95862702 355.00 -1.07036609e+01 -2.03418883e-01 1.07055937e+01 -3.12259033 0.95001629 355.25 -9.72567240e+00 5.03638726e-03 9.72567370e+00 3.14107481 0.92791655 355.50 -8.30990572e+00 9.45337766e-02 8.31044341e+00 3.13021711 0.94659035 355.75 -7.71577397e+00 -6.48656683e-01 7.74299189e+00 -3.05772097 0.94195100 356.00 -7.13611252e+00 -9.52338446e-01 7.19937847e+00 -3.00892316 0.96155152 356.25 -6.66086462e+00 -8.46646020e-01 6.71445657e+00 -3.01516310 0.94608248 356.50 -6.49469914e+00 -6.95334383e-01 6.53181497e+00 -3.03493709 0.94805145 356.75 -6.06952153e+00 -6.40207371e-01 6.10319237e+00 -3.03650219 0.94474275 357.00 -5.76948706e+00 -4.20867778e-01 5.78481725e+00 -3.06877446 0.95936689 357.25 -4.99631660e+00 -3.22336203e-01 5.00670353e+00 -3.07716717 0.93670870 357.50 -4.51037189e+00 -2.24881203e-01 4.51597455e+00 -3.09177522 0.93635244 357.75 -3.57954156e+00 -1.09667609e-01 3.58122113e+00 -3.11096490 0.85831858 358.00 -2.87976443e+00 -1.72799136e-01 2.88494415e+00 -3.08165991 0.78280551 358.25 -1.28541763e+00 -4.96422702e-01 1.37794556e+00 -2.77304292 0.34391275 358.50 -8.51101147e-02 -1.08204368e+00 1.08538576e+00 -1.64929153 0.23660548 358.75 1.01213271e+00 -2.97308003e+00 3.14063966e+00 -1.24267029 0.69471702 359.00 1.01438792e+00 -4.18792904e+00 4.30902918e+00 -1.33315608 0.76137072 359.25 -1.02890885e+00 -7.12342599e+00 7.19735030e+00 -1.71424440 0.85244058 359.50 -2.70582231e+00 -7.96809921e+00 8.41499135e+00 -1.89816001 0.88478223 359.75 -5.30688846e+00 -7.18071740e+00 8.92892868e+00 -2.20725066 0.92976293 360.00 -5.72849726e+00 -6.27728600e+00 8.49823514e+00 -2.31051592 0.94541471 360.25 -5.38502271e+00 -5.08327690e+00 7.40528012e+00 -2.38501123 0.96992673 360.50 -5.03493033e+00 -4.88678859e+00 7.01649671e+00 -2.37112444 0.97258882 360.75 -4.55738144e+00 -4.83468899e+00 6.64409085e+00 -2.32667735 0.98128840 361.00 -4.35230982e+00 -5.08575568e+00 6.69384132e+00 -2.27863890 0.96645023 361.25 -4.10785183e+00 -6.48438868e+00 7.67604997e+00 -2.13548374 0.96611375 361.50 -4.11197833e+00 -7.24142880e+00 8.32746401e+00 -2.08723359 0.94008015 361.75 -5.49437010e+00 -9.87306318e+00 1.12989150e+01 -2.07861705 0.90911551 362.00 -5.95616070e+00 -1.13225357e+01 1.27935790e+01 -2.05506200 0.87315284 362.25 -8.85143984e+00 -1.23642514e+01 1.52060087e+01 -2.19210709 0.61577469 362.50 -7.16238029e+00 -2.90117435e+00 7.72764544e+00 -2.75673416 0.17394253 362.75 -5.40035817e+00 8.46445274e+00 1.00404596e+01 2.13869252 0.53008093 363.00 -5.47299640e+00 7.10222019e+00 8.96633823e+00 2.22735386 0.67625339 363.25 -5.61169427e+00 5.58569473e+00 7.91777103e+00 2.35851641 0.79556458 363.50 -3.92480922e+00 5.72251458e+00 6.93911382e+00 2.17196507 0.79195674 363.75 -3.38184047e+00 5.26537468e+00 6.25787628e+00 2.14172473 0.86813638 364.00 -3.40166964e+00 4.38469713e+00 5.54949775e+00 2.23060908 0.85359419 364.25 -3.25851381e+00 4.12434674e+00 5.25624851e+00 2.23945168 0.90614721 364.50 -2.89149592e+00 4.10569210e+00 5.02169854e+00 2.18437909 0.87761282 364.75 -2.79590769e+00 4.15064196e+00 5.00449083e+00 2.16358943 0.93203143 365.00 -2.75933447e+00 4.26791250e+00 5.08222430e+00 2.14472848 0.94135871 365.25 -2.62196862e+00 4.45277059e+00 5.16738671e+00 2.10296939 0.94704256 365.50 -2.35127680e+00 4.99647844e+00 5.52207383e+00 2.01063773 0.90506151 365.75 -1.87063626e+00 5.66116136e+00 5.96221670e+00 1.88993459 0.93099360 366.00 -5.01991180e-01 6.17790542e+00 6.19826673e+00 1.65187409 0.90229068 366.25 1.04456789e+00 6.01051320e+00 6.10060579e+00 1.39872482 0.88840711 366.50 2.70674141e+00 4.44818743e+00 5.20699726e+00 1.02414708 0.86210078 366.75 3.28935510e+00 3.60821095e+00 4.88252427e+00 0.83159258 0.90333430 367.00 3.10903315e+00 1.78102565e+00 3.58303495e+00 0.52022087 0.76322256 367.25 2.92984359e+00 8.79406041e-01 3.05897670e+00 0.29159863 0.81133653 367.50 2.23315164e+00 3.32562344e-01 2.25777854e+00 0.14783416 0.77533344 367.75 2.04382029e+00 1.03572941e-01 2.04644295e+00 0.05063284 0.82138378 368.00 1.93483456e+00 1.66008025e-02 1.93490577e+00 0.00857975 0.77631752 368.25 1.76059384e+00 -1.07839659e-01 1.76389344e+00 -0.06117544 0.73068868 368.50 1.46112227e+00 -3.19654762e-01 1.49567960e+00 -0.21538008 0.63992745 368.75 1.29289236e+00 -4.36899106e-01 1.36471663e+00 -0.32587627 0.57831667 369.00 1.25246058e+00 -8.50565758e-01 1.51397477e+00 -0.59657178 0.53184981 369.25 9.47035216e-01 -9.47003423e-01 1.33928757e+00 -0.78538138 0.45526708 369.50 2.32556912e-01 -7.37631397e-01 7.73422779e-01 -1.26538513 0.29448848 369.75 1.22024110e-01 -5.77135293e-01 5.89894083e-01 -1.36243427 0.22686064 370.00 -2.99245467e-01 -1.72220596e-01 3.45264802e-01 -2.61937057 0.07912740 370.25 -2.30241427e-01 4.01117409e-02 2.33709364e-01 2.96910779 0.04012936 370.50 -4.48197673e-02 4.02125973e-01 4.04616002e-01 1.68179524 0.13761090 370.75 8.84909675e-02 6.00078904e-01 6.06568497e-01 1.42438597 0.26249818 371.00 3.39779257e-01 7.09819853e-01 7.86952456e-01 1.12434664 0.42248959 371.25 5.26995116e-01 7.37880276e-01 9.06747569e-01 0.95060268 0.49591034 371.50 9.71247027e-01 7.15162711e-01 1.20614199e+00 0.63469768 0.69132984 371.75 1.13075837e+00 6.18769042e-01 1.28898783e+00 0.50070325 0.70757514 372.00 1.39350890e+00 4.76373876e-01 1.47268432e+00 0.32939771 0.76266421 372.25 1.51443666e+00 2.61184905e-01 1.53679405e+00 0.17078339 0.68628688 372.50 1.04866304e+00 -6.03935328e-01 1.21013720e+00 -0.52251775 0.59494662 372.75 5.88626472e-01 -9.33528233e-01 1.10361048e+00 -1.00822343 0.51002474 373.00 -4.06900036e-01 -1.05483926e+00 1.13059874e+00 -1.93895471 0.27485123 373.25 -7.33573643e-01 3.09798804e-02 7.34227514e-01 3.09938628 0.05818967 373.50 1.43895785e-01 3.16715329e+00 3.17042047e+00 1.52539376 0.59957400 373.75 1.10104016e+00 4.30943664e+00 4.44786844e+00 1.32065248 0.75762360 374.00 2.56030304e+00 4.80813936e+00 5.44732556e+00 1.08149306 0.86144802 374.25 4.31005942e+00 4.06426675e+00 5.92409287e+00 0.75605585 0.85210433 374.50 6.05947391e+00 2.62343693e+00 6.60300276e+00 0.40858334 0.92855115 374.75 6.49815416e+00 1.45992921e+00 6.66013519e+00 0.22099870 0.91168247 375.00 6.74538111e+00 3.85045635e-01 6.75636193e+00 0.05702098 0.95539639 375.25 6.87372616e+00 -5.08248110e-01 6.89249066e+00 -0.07380639 0.94683798 375.50 6.87125546e+00 -1.61269090e+00 7.05796879e+00 -0.23052864 0.95978078 375.75 6.16257209e+00 -2.48407764e+00 6.64439135e+00 -0.38316823 0.95575114 376.00 5.96446984e+00 -2.77016870e+00 6.57637705e+00 -0.43480132 0.97724889 376.25 5.84669178e+00 -3.06029612e+00 6.59918306e+00 -0.48221037 0.95446745 376.50 5.71865495e+00 -3.52685521e+00 6.71875897e+00 -0.55262886 0.96399932 376.75 5.54843737e+00 -3.98723368e+00 6.83250977e+00 -0.62311546 0.96550664 377.00 5.32891227e+00 -4.39891950e+00 6.90997820e+00 -0.69008659 0.97162653 377.25 5.01754305e+00 -4.72308226e+00 6.89080869e+00 -0.75517719 0.96220908 377.50 5.02010907e+00 -5.10513301e+00 7.15987976e+00 -0.79379519 0.95941638 377.75 4.25668663e+00 -6.11599402e+00 7.45149407e+00 -0.96276495 0.95367345 378.00 3.47069739e+00 -6.45475228e+00 7.32868115e+00 -1.07744827 0.95725761 378.25 2.38147139e+00 -6.23609538e+00 6.67534954e+00 -1.20600318 0.96813752 378.50 1.98682562e+00 -6.16816631e+00 6.48025861e+00 -1.25918091 0.96762656 378.75 1.59537067e+00 -5.81833701e+00 6.03309648e+00 -1.30317679 0.93659029 379.00 1.23287540e+00 -5.55485557e+00 5.69002655e+00 -1.35239106 0.91995462 379.25 1.02425867e+00 -4.37592168e+00 4.49419585e+00 -1.34086876 0.89863508 379.50 1.06190113e+00 -4.11961621e+00 4.25427687e+00 -1.31852101 0.89559914 379.75 1.78397122e+00 -3.44708414e+00 3.88135832e+00 -1.09322286 0.87090453 380.00 2.18037257e+00 -3.34186678e+00 3.99025039e+00 -0.99270668 0.85946586 380.25 2.88231043e+00 -4.64513143e+00 5.46671377e+00 -1.01543852 0.87874124 380.50 2.72037636e+00 -5.00231041e+00 5.69416868e+00 -1.07270714 0.90149255 380.75 2.93131444e+00 -4.31213988e+00 5.21413029e+00 -0.97376885 0.91251394 381.00 3.26288440e+00 -4.42285839e+00 5.49618877e+00 -0.93519305 0.89426159 381.25 3.74779835e+00 -5.74511958e+00 6.85947457e+00 -0.99277457 0.87722369 381.50 3.48877912e+00 -6.76819369e+00 7.61446161e+00 -1.09485198 0.90698130 381.75 1.76893207e+00 -7.51625120e+00 7.72160299e+00 -1.33965494 0.93106311 382.00 1.04787532e+00 -7.33439699e+00 7.40887454e+00 -1.42888533 0.93601736 382.25 2.17122620e-01 -6.72203630e+00 6.72554193e+00 -1.53850743 0.94071889 382.50 2.26106541e-01 -6.16084424e+00 6.16499197e+00 -1.53411221 0.95182773 382.75 4.08358755e-02 -5.91037757e+00 5.91051864e+00 -1.56388725 0.96196875 383.00 -8.00194619e-02 -5.53959365e+00 5.54017156e+00 -1.58524033 0.95637022 383.25 1.22170997e-01 -5.07005984e+00 5.07153157e+00 -1.54670443 0.94736370 383.50 3.10581423e-01 -4.73750005e+00 4.74766970e+00 -1.50533192 0.94080997 383.75 4.41532664e-01 -4.64378456e+00 4.66472787e+00 -1.47600095 0.91713698 384.00 6.16362799e-01 -4.28865245e+00 4.33271773e+00 -1.42805431 0.88387997 384.25 7.68685514e-01 -3.84328690e+00 3.91940450e+00 -1.37339373 0.88324305 384.50 1.00273017e+00 -3.31886732e+00 3.46703736e+00 -1.27738633 0.80654706 384.75 1.16458002e+00 -2.62677637e+00 2.87336053e+00 -1.15348669 0.72206883 385.00 1.04810440e+00 -2.07835401e+00 2.32767657e+00 -1.10371829 0.49017742 385.25 1.30004796e+00 -1.26474165e+00 1.81375196e+00 -0.77163326 0.28658696 385.50 1.50708357e+00 -4.62421144e-01 1.57643084e+00 -0.29771264 0.16539102 385.75 2.14836459e+00 2.37387009e+00 3.20167607e+00 0.83522284 0.30725051 386.00 4.71313241e+00 4.07249306e+00 6.22886963e+00 0.71260796 0.55691936 386.25 7.33818143e+00 4.66234174e+00 8.69404033e+00 0.56601015 0.70222217 386.50 7.08676279e+00 4.22744417e+00 8.25187803e+00 0.53786179 0.62612796 386.75 5.99310497e+00 5.03079132e+00 7.82471523e+00 0.69832546 0.67135576 387.00 4.59842933e+00 5.30666580e+00 7.02184122e+00 0.85677892 0.68538002 387.25 3.21122437e+00 5.20895876e+00 6.11924941e+00 1.01834646 0.62252143 387.50 5.99152847e-01 4.12675158e+00 4.17001951e+00 1.42661625 0.51618597 387.75 -4.37069676e-01 3.40895912e+00 3.43686371e+00 1.69831271 0.55271260 388.00 -2.35745067e+00 1.69552868e+00 2.90385798e+00 2.51808265 0.54297202 388.25 -3.36615174e+00 9.52195079e-01 3.49823570e+00 2.86592136 0.74117368 388.50 -3.85967949e+00 -1.20224155e-01 3.86155145e+00 -3.11045398 0.84166718 388.75 -3.97569854e+00 -4.73378327e-01 4.00378145e+00 -3.02308263 0.88772150 389.00 -4.20129534e+00 -1.21179542e+00 4.37256569e+00 -2.86078057 0.92612623 389.25 -4.26033047e+00 -1.64079330e+00 4.56537165e+00 -2.77396810 0.93486684 389.50 -4.35217292e+00 -2.43682694e+00 4.98793892e+00 -2.63117253 0.93910675 389.75 -4.47416142e+00 -2.70620792e+00 5.22892740e+00 -2.59761274 0.94612123 390.00 -4.76268184e+00 -3.25713610e+00 5.76992841e+00 -2.54176285 0.93953834 390.25 -4.76391602e+00 -3.51222076e+00 5.91866459e+00 -2.50629839 0.93456101 390.50 -5.59144772e+00 -3.84099534e+00 6.78362239e+00 -2.53968491 0.95277196 390.75 -5.97202145e+00 -3.86839322e+00 7.11544140e+00 -2.56679886 0.96532634 391.00 -6.64664174e+00 -3.67317945e+00 7.59408281e+00 -2.63672721 0.96445194 391.25 -7.03762662e+00 -3.59447775e+00 7.90243373e+00 -2.66938095 0.97168875 391.50 -7.66834097e+00 -2.70333047e+00 8.13089472e+00 -2.80266453 0.97533032 391.75 -7.76419080e+00 -1.99707435e+00 8.01691740e+00 -2.88983405 0.97178532 392.00 -7.94522284e+00 -1.18617351e+00 8.03327913e+00 -2.99339331 0.97153081 392.25 -7.59771041e+00 -7.83699548e-01 7.63802255e+00 -3.03880673 0.96131821 392.50 -7.18824450e+00 -5.35928479e-01 7.20819522e+00 -3.06717410 0.96173339 392.75 -7.04715755e+00 -3.24725836e-01 7.05463510e+00 -3.09554624 0.95614509 393.00 -6.50168202e+00 6.20301223e-01 6.53120530e+00 3.04647429 0.96215249 393.25 -6.07296174e+00 8.20598156e-01 6.12815190e+00 3.00728291 0.95229728 393.50 -5.38062784e+00 1.25603379e+00 5.52528522e+00 2.91226308 0.92847342 393.75 -4.92456262e+00 1.59756580e+00 5.17721290e+00 2.82789661 0.92423377 394.00 -4.18712397e+00 1.71087240e+00 4.52317272e+00 2.75369177 0.92840475 394.25 -3.35721556e+00 2.06492429e+00 3.94142216e+00 2.59016553 0.82416373 394.50 -1.84357012e+00 2.29869006e+00 2.94664670e+00 2.24676107 0.73984452 394.75 -1.06032037e+00 2.26491249e+00 2.50082144e+00 2.00864144 0.55894369 395.00 4.22797793e-02 2.02169324e+00 2.02213530e+00 1.54988632 0.30081656 395.25 5.08946034e-01 1.25286484e+00 1.35229300e+00 1.18493442 0.10570166 395.50 1.18822428e+00 -3.79632715e-01 1.24739647e+00 -0.30924555 0.08029673 395.75 6.64248288e-01 -2.10788882e+00 2.21007264e+00 -1.26552187 0.12994808 396.00 1.08495328e+00 -3.19859269e+00 3.37759068e+00 -1.24377772 0.16754735 396.25 2.05862836e+00 -2.46595280e+00 3.21230042e+00 -0.87518092 0.15378485 396.50 1.78692675e+00 -3.42837227e+00 3.86611479e+00 -1.09031935 0.17336760 396.75 1.67871428e+00 -7.86666229e+00 8.04378377e+00 -1.36055380 0.42353383 397.00 1.44707436e+00 -1.04049781e+01 1.05051222e+01 -1.43260753 0.70483486 397.25 1.66731983e+00 -1.27822994e+01 1.28905831e+01 -1.44108891 0.80045287 397.50 8.04848378e-01 -1.37713091e+01 1.37948083e+01 -1.51241888 0.75910596 397.75 4.59518483e-01 -1.48429367e+01 1.48500481e+01 -1.53984748 0.74224422 398.00 1.22591667e+00 -1.66762479e+01 1.67212474e+01 -1.49741558 0.74450862 398.25 1.30337506e+00 -1.91023578e+01 1.91467716e+01 -1.50267081 0.77112282 398.50 3.00563371e+00 -2.11064733e+01 2.13194054e+01 -1.42934396 0.75266974 398.75 4.07163957e+00 -2.60604615e+01 2.63766166e+01 -1.41581110 0.65783117 399.00 4.55542842e+00 -3.32817240e+01 3.35920389e+01 -1.43476684 0.64756174 399.25 -8.56708143e-02 -3.33531173e+01 3.33532273e+01 -1.57336492 0.40263929 399.50 1.36161924e+00 -3.20247745e+01 3.20537078e+01 -1.52830424 0.32166203 399.75 1.19964957e+01 -1.75671270e+01 2.12725142e+01 -0.97164300 0.15204431 400.00 1.18254788e+01 1.37217729e+00 1.19048234e+01 0.11551905 0.07156918 400.25 1.22897548e+01 6.82337261e+00 1.40569017e+01 0.50683303 0.25518317 400.50 1.15510857e+01 8.29383811e+00 1.42202437e+01 0.62271369 0.47831117 400.75 4.65761552e+00 8.00769470e+00 9.26372262e+00 1.04398437 0.57575544 401.00 1.98371172e+00 6.91873581e+00 7.19750077e+00 1.29157087 0.64465164 401.25 -1.52387185e-01 6.17732653e+00 6.17920585e+00 1.59546012 0.68660119 401.50 -1.59744993e+00 5.87234238e+00 6.08574164e+00 1.83639873 0.73840403 401.75 -2.48035745e+00 5.49687123e+00 6.03056933e+00 1.99467329 0.85304472 402.00 -2.80707760e+00 5.43857366e+00 6.12027517e+00 2.04727418 0.83056446 402.25 -3.79947369e+00 5.42468652e+00 6.62293168e+00 2.18179357 0.83400224 402.50 -4.79078150e+00 5.60256149e+00 7.37158617e+00 2.27824698 0.85201760 402.75 -3.98875458e+00 5.80913702e+00 7.04671810e+00 2.17249580 0.85417018 403.00 -3.44267494e+00 5.83733354e+00 6.77690737e+00 2.10365863 0.80879965 403.25 -2.96906565e+00 5.28882837e+00 6.06523341e+00 2.08233791 0.61534350 403.50 -2.26337972e+00 5.08593090e+00 5.56682862e+00 1.98950753 0.45565151 403.75 -2.11812035e+00 3.55663456e+00 4.13957525e+00 2.10793042 0.17329519 404.00 -8.86840869e-01 1.52309921e+00 1.76247495e+00 2.09807012 0.02389553 404.25 -1.47486492e+00 -2.46997627e-01 1.49540442e+00 -2.97566114 0.01100815 404.50 7.45813953e-01 2.79090444e+00 2.88883818e+00 1.30966789 0.05052689 404.75 1.44631406e+00 2.01851345e+00 2.48318765e+00 0.94906606 0.06117988 405.00 9.47629634e-02 -8.88789463e-02 1.29921077e-01 -0.75336841 0.00031911 405.25 -2.78971428e+00 -1.77759980e+00 3.30792485e+00 -2.57426993 0.23313039 405.50 -5.73479418e+00 -1.86750521e+00 6.03120552e+00 -2.82677777 0.65037423 405.75 -7.36769938e+00 -8.74246865e-01 7.41938689e+00 -3.02348550 0.79881135 406.00 -9.07109983e+00 5.44630878e-01 9.08743500e+00 3.08162442 0.82376561 406.25 -1.07078643e+01 1.98416171e+00 1.08901449e+01 2.95837133 0.90623822 406.50 -1.18772108e+01 3.06567333e+00 1.22664783e+01 2.88899207 0.89778943 406.75 -1.27788815e+01 5.01799531e+00 1.37288051e+01 2.76741358 0.91579533 407.00 -1.25806542e+01 7.54622819e+00 1.46703245e+01 2.60129966 0.87452810 407.25 -1.19478278e+01 9.68813883e+00 1.53821528e+01 2.46025853 0.88249868 407.50 -1.12015770e+01 1.20845761e+01 1.64776305e+01 2.31829316 0.84385723 407.75 -9.84653374e+00 1.39690823e+01 1.70906257e+01 2.18479029 0.84703341 408.00 -5.13032082e+00 1.44060196e+01 1.52922723e+01 1.91291585 0.77591658 408.25 -3.13075432e+00 1.31086169e+01 1.34772942e+01 1.80523642 0.73450082 408.50 -3.80114558e+00 1.05300848e+01 1.11951504e+01 1.91721883 0.69892699 408.75 -3.26310017e+00 9.79067541e+00 1.03201331e+01 1.89250475 0.71046774 409.00 -5.35105770e+00 1.08434465e+01 1.20919044e+01 2.02921684 0.75941639 409.25 -5.59682491e+00 1.13460013e+01 1.26513317e+01 2.02905842 0.80184627 409.50 -4.65485952e+00 1.18709782e+01 1.27509937e+01 1.94449204 0.82478186 409.75 -3.49999407e+00 1.35024140e+01 1.39486610e+01 1.82442658 0.83333438 410.00 -2.33973419e+00 1.40070925e+01 1.42011618e+01 1.73630749 0.82179985 410.25 -1.86364723e+00 1.37229381e+01 1.38489065e+01 1.70577582 0.81996791 410.50 -1.34299879e+00 1.51479386e+01 1.52073564e+01 1.65922397 0.77704895 410.75 -3.88112256e-01 1.77346193e+01 1.77388656e+01 1.59267728 0.83577948 411.00 4.74982539e-01 1.79710260e+01 1.79773019e+01 1.54437202 0.87611253 411.25 1.48399530e+00 1.72663440e+01 1.73299993e+01 1.48505974 0.82533871 411.50 4.13020059e+00 1.68435975e+01 1.73425873e+01 1.33033196 0.83527714 411.75 4.46941850e+00 1.60520628e+01 1.66626655e+01 1.29924161 0.82239632 412.00 7.89824804e+00 1.52235122e+01 1.71504415e+01 1.09220708 0.84462967 412.25 8.93545755e+00 1.50660460e+01 1.75165106e+01 1.03547633 0.87381304 412.50 9.32010150e+00 1.57818858e+01 1.83284536e+01 1.03734922 0.91699451 412.75 1.01967107e+01 1.48154248e+01 1.79852640e+01 0.96800013 0.88456625 413.00 1.39492000e+01 1.30772604e+01 1.91205367e+01 0.75314691 0.91130022 413.25 1.37740200e+01 1.26322099e+01 1.86894718e+01 0.74218490 0.91037015 413.50 1.35535003e+01 1.10802351e+01 1.75062554e+01 0.68533195 0.91897023 413.75 1.45294120e+01 1.02664858e+01 1.77905746e+01 0.61514193 0.92466911 414.00 1.53797636e+01 9.79596799e+00 1.82345309e+01 0.56713848 0.95497338 414.25 1.58712172e+01 9.42650879e+00 1.84595397e+01 0.53594975 0.94670493 414.50 1.68760721e+01 8.54297685e+00 1.89151861e+01 0.46860988 0.95622679 414.75 1.79038990e+01 7.86553161e+00 1.95554644e+01 0.41393659 0.95608101 415.00 1.92777071e+01 6.19573343e+00 2.02488791e+01 0.31096667 0.96643842 415.25 1.92770600e+01 4.60115247e+00 1.98185683e+01 0.23430159 0.96834502 415.50 1.90564622e+01 2.57281553e+00 1.92293560e+01 0.13419868 0.96802670 415.75 1.96637144e+01 5.47548492e-01 1.96713363e+01 0.02783844 0.94382595 416.00 1.92001068e+01 -2.16696972e+00 1.93220045e+01 -0.11238680 0.93293464 416.25 1.76426909e+01 -4.35807090e+00 1.81729834e+01 -0.24217058 0.91329440 416.50 1.61938543e+01 -6.60289611e+00 1.74882576e+01 -0.38716167 0.93571057 416.75 1.45472022e+01 -7.22874242e+00 1.62442547e+01 -0.46117764 0.89884477 417.00 1.30006447e+01 -7.14233439e+00 1.48333982e+01 -0.50236946 0.91619829 417.25 1.19848238e+01 -7.65960491e+00 1.42234155e+01 -0.56868061 0.90062862 417.50 9.78306929e+00 -8.21971850e+00 1.27778017e+01 -0.69877610 0.91162953 417.75 9.13753732e+00 -8.00799823e+00 1.21500051e+01 -0.71961374 0.91245820 418.00 8.56949469e+00 -8.03244489e+00 1.17454847e+01 -0.75306082 0.95033650 418.25 7.30064340e+00 -8.09874544e+00 1.09036265e+01 -0.83717870 0.93209904 418.50 6.86284943e+00 -8.45938949e+00 1.08931158e+01 -0.88922108 0.94565781 418.75 5.98541050e+00 -7.87796633e+00 9.89381081e+00 -0.92107426 0.93012851 419.00 5.30951897e+00 -7.26026790e+00 8.99458069e+00 -0.93936340 0.93519854 419.25 4.60138724e+00 -6.88185817e+00 8.27845012e+00 -0.98143869 0.93124170 419.50 4.55414350e+00 -7.02299741e+00 8.37034741e+00 -0.99550341 0.94743285 419.75 4.72889566e+00 -6.35263602e+00 7.91949736e+00 -0.93088953 0.93256114 420.00 4.75584947e+00 -6.07800307e+00 7.71752717e+00 -0.90683675 0.93422752 420.25 4.09331295e+00 -5.71513850e+00 7.02979509e+00 -0.94926530 0.92706472 420.50 3.85879710e+00 -5.48804625e+00 6.70887224e+00 -0.95797435 0.92258672 420.75 3.91198011e+00 -5.63337387e+00 6.85846116e+00 -0.96381885 0.86727929 421.00 3.85895993e+00 -5.70563635e+00 6.88809538e+00 -0.97612548 0.87327915 421.25 3.20963097e+00 -5.28661577e+00 6.18466145e+00 -1.02515510 0.80928361 421.50 3.02819973e+00 -5.07972983e+00 5.91385228e+00 -1.03322431 0.80987194 421.75 2.76199922e+00 -4.92708689e+00 5.64843562e+00 -1.05987077 0.88033976 422.00 2.56398356e+00 -4.54141904e+00 5.21521799e+00 -1.05683002 0.88071878 422.25 2.42384018e+00 -3.92218849e+00 4.61070101e+00 -1.01725990 0.89909045 422.50 2.51522613e+00 -3.55546377e+00 4.35519059e+00 -0.95510410 0.86293616 422.75 2.75783257e+00 -3.04916772e+00 4.11133364e+00 -0.83552578 0.84039446 423.00 3.03167228e+00 -2.76770658e+00 4.10502577e+00 -0.73991336 0.81725306 423.25 4.05762871e+00 -2.02291214e+00 4.53393034e+00 -0.46248326 0.85465336 423.50 4.53105536e+00 -1.97552550e+00 4.94299137e+00 -0.41114802 0.86916951 423.75 5.54090493e+00 -2.17419225e+00 5.95220459e+00 -0.37392833 0.91367885 424.00 5.80967304e+00 -2.34578221e+00 6.26538067e+00 -0.38375370 0.89526342 424.25 6.28537912e+00 -2.53890169e+00 6.77879137e+00 -0.38389634 0.89056571 424.50 6.93981114e+00 -2.83154269e+00 7.49523933e+00 -0.38739617 0.88491501 424.75 7.78604710e+00 -3.60408786e+00 8.57974235e+00 -0.43352188 0.88773555 425.00 8.29462638e+00 -4.55032012e+00 9.46077375e+00 -0.50175735 0.88186396 425.25 8.98874447e+00 -5.37880656e+00 1.04751653e+01 -0.53923744 0.91021360 425.50 8.95555688e+00 -6.58604761e+00 1.11165652e+01 -0.63410094 0.88859009 425.75 9.38990117e+00 -8.03189505e+00 1.23564389e+01 -0.70760678 0.88732086 426.00 8.13406788e+00 -9.52153376e+00 1.25228857e+01 -0.86382201 0.85547105 426.25 6.19199750e+00 -1.11895032e+01 1.27885032e+01 -1.06536522 0.85013440 426.50 3.73353531e+00 -1.12129358e+01 1.18181731e+01 -1.24937569 0.77256427 426.75 1.16747454e+00 -1.14153946e+01 1.14749393e+01 -1.46887874 0.78716509 427.00 3.78511706e-01 -1.00202395e+01 1.00273860e+01 -1.53303956 0.74084657 427.25 -2.52236298e-01 -9.37414641e+00 9.37753934e+00 -1.59769749 0.77021143 427.50 -7.88970514e-01 -8.15498589e+00 8.19306227e+00 -1.66724317 0.70478000 427.75 -1.66485673e+00 -7.35110511e+00 7.53727366e+00 -1.79351622 0.77645113 428.00 -2.37090144e+00 -5.96627539e+00 6.42009468e+00 -1.94904536 0.66738418 428.25 -3.13355914e+00 -4.65102755e+00 5.60814142e+00 -2.16367631 0.61761371 428.50 -2.60958339e+00 -2.89717748e+00 3.89917464e+00 -2.30401626 0.44306895 428.75 -2.75288852e+00 -1.80859373e+00 3.29384372e+00 -2.56032596 0.48222367 429.00 -2.31807221e+00 -7.20188887e-01 2.42737117e+00 -2.84036270 0.34234761 429.25 -2.08911438e+00 -1.07297642e-01 2.09186799e+00 -3.09027740 0.41685151 429.50 -1.22496096e+00 5.43217106e-01 1.34000529e+00 2.72419347 0.16487505 429.75 -5.75402636e-01 8.22057351e-01 1.00342737e+00 2.18149167 0.09231335 430.00 -1.83728415e-01 1.13145926e+00 1.14627928e+00 1.73177309 0.11296956 430.25 2.02872213e-01 1.56195003e+00 1.57506985e+00 1.44163546 0.23865010 430.50 4.37603186e-01 2.62101582e+00 2.65729570e+00 1.40536286 0.46905270 430.75 8.40926412e-01 3.16621024e+00 3.27597993e+00 1.31119566 0.56633887 431.00 1.64300270e+00 3.79270252e+00 4.13328565e+00 1.16199988 0.62218889 431.25 1.82430604e+00 4.20200041e+00 4.58092785e+00 1.16119963 0.69758970 431.50 2.39458233e+00 4.66250498e+00 5.24146709e+00 1.09634162 0.74982679 431.75 2.52280443e+00 4.96914789e+00 5.57287833e+00 1.10101282 0.79741163 432.00 2.66278021e+00 4.81113515e+00 5.49885624e+00 1.06529908 0.82265477 432.25 2.84866193e+00 4.98670392e+00 5.74300363e+00 1.05178373 0.80472183 432.50 2.01191130e+00 5.81708717e+00 6.15518401e+00 1.23781238 0.80885865 432.75 1.43800174e+00 5.97707439e+00 6.14762290e+00 1.33469713 0.84138315 433.00 1.53196469e+00 8.32242223e+00 8.46224719e+00 1.38875738 0.85203733 433.25 2.94495148e+00 9.67904807e+00 1.01171493e+01 1.27543546 0.90237239 433.50 4.74534179e+00 9.61920156e+00 1.07260108e+01 1.11250721 0.94615997 433.75 5.14519398e+00 9.39623283e+00 1.07127127e+01 1.06981259 0.93398706 434.00 6.51650763e+00 8.63222158e+00 1.08157349e+01 0.92416337 0.93629514 434.25 6.87571963e+00 8.58401939e+00 1.09982230e+01 0.89545160 0.92502245 434.50 7.52858717e+00 7.76051107e+00 1.08122688e+01 0.80056623 0.92514954 434.75 7.97825396e+00 7.06819546e+00 1.06588894e+01 0.72498848 0.91360778 435.00 8.17942742e+00 5.50372784e+00 9.85870443e+00 0.59228800 0.91586547 435.25 8.01135568e+00 4.48369020e+00 9.18070246e+00 0.51023467 0.90259457 435.50 7.61463644e+00 3.56688515e+00 8.40864780e+00 0.43806997 0.91603989 435.75 7.02895162e+00 2.64954593e+00 7.51174111e+00 0.36047700 0.87979962 436.00 5.86214157e+00 2.13844551e+00 6.24000425e+00 0.34978876 0.90149108 436.25 4.72096004e+00 2.32396834e+00 5.26196660e+00 0.45744133 0.85764499 436.50 3.56605206e+00 2.87040749e+00 4.57776872e+00 0.67773730 0.90783924 436.75 3.24996116e+00 3.35885033e+00 4.67376969e+00 0.80187303 0.88423755 437.00 3.05668490e+00 4.23866179e+00 5.22585652e+00 0.94602035 0.94686335 437.25 3.15042225e+00 4.72267789e+00 5.67704561e+00 0.98250494 0.94184642 437.50 3.21521492e+00 5.19805526e+00 6.11206884e+00 1.01685453 0.95665672 437.75 3.30250621e+00 5.30558768e+00 6.24946460e+00 1.01402696 0.94534541 438.00 3.40910024e+00 5.16897154e+00 6.19194890e+00 0.98774964 0.94725362 438.25 3.73830680e+00 5.29219609e+00 6.47937321e+00 0.95580063 0.94312527 438.50 3.91188732e+00 5.22406898e+00 6.52638944e+00 0.92805085 0.95822566 438.75 4.07845527e+00 5.03115694e+00 6.47659923e+00 0.88960138 0.92864196 439.00 4.33377669e+00 5.11364637e+00 6.70305897e+00 0.86775983 0.95261181 439.25 4.48291589e+00 4.80496574e+00 6.57147097e+00 0.82005848 0.93419281 439.50 4.51751127e+00 4.92112276e+00 6.68022135e+00 0.82813377 0.95175576 439.75 4.82251284e+00 4.83031055e+00 6.82557911e+00 0.78620598 0.94744792 440.00 4.97928485e+00 4.72364086e+00 6.86338551e+00 0.75905715 0.95112390 440.25 5.03158379e+00 4.43738963e+00 6.70874520e+00 0.72272864 0.93034210 440.50 5.22004625e+00 4.32361809e+00 6.77809385e+00 0.69174381 0.92920218 440.75 5.53334614e+00 4.17190885e+00 6.92984436e+00 0.64602922 0.93480266 441.00 5.58279298e+00 4.07747752e+00 6.91327711e+00 0.63081593 0.92461531 441.25 6.67138064e+00 4.10672105e+00 7.83405881e+00 0.55179153 0.91674163 441.50 6.94708765e+00 4.01182375e+00 8.02226631e+00 0.52369818 0.93390859 441.75 7.54310038e+00 3.39997562e+00 8.27394692e+00 0.42346898 0.91944550 442.00 8.15129032e+00 2.93358257e+00 8.66310802e+00 0.34545979 0.92135106 442.25 8.88731225e+00 1.61673316e+00 9.03316916e+00 0.17994697 0.92402285 442.50 9.03779181e+00 1.20913632e+00 9.11831626e+00 0.13299695 0.92374753 442.75 9.73377446e+00 -9.75825212e-02 9.73426359e+00 -0.01002481 0.94530022 443.00 9.61638925e+00 -7.19040890e-01 9.64323400e+00 -0.07463356 0.94786518 443.25 1.00992138e+01 -2.16108515e+00 1.03278463e+01 -0.21080627 0.94664975 443.50 1.02170713e+01 -2.94680645e+00 1.06335420e+01 -0.28079926 0.92664841 443.75 9.80164894e+00 -5.69976400e+00 1.13384140e+01 -0.52671350 0.92176772 444.00 9.40590368e+00 -7.16468021e+00 1.18238601e+01 -0.65096084 0.91899909 444.25 8.00461752e+00 -1.05899470e+01 1.32748212e+01 -0.92354933 0.92934655 444.50 6.27808594e+00 -1.20054695e+01 1.35479025e+01 -1.08896914 0.89537291 444.75 1.27047732e+00 -1.42353912e+01 1.42919724e+01 -1.48178436 0.92191007 445.00 -7.02855033e-01 -1.35634045e+01 1.35816032e+01 -1.62256997 0.90629202 445.25 -5.30874032e+00 -1.13273452e+01 1.25096552e+01 -2.00906393 0.87883884 445.50 -7.00021753e+00 -8.46404347e+00 1.09837643e+01 -2.26181706 0.88487042 445.75 -7.07001339e+00 -5.13711339e+00 8.73928048e+00 -2.51323265 0.90494462 446.00 -6.61346502e+00 -3.59837217e+00 7.52902397e+00 -2.64329213 0.84920628 446.25 -5.32951003e+00 -2.05924233e+00 5.71350646e+00 -2.77287823 0.80495679 446.50 -4.71594887e+00 -1.86167930e+00 5.07011080e+00 -2.76560959 0.76578260 446.75 -4.20272396e+00 -1.40260711e+00 4.43059764e+00 -2.81947828 0.75432754 447.00 -4.37543863e+00 -7.50497875e-01 4.43933670e+00 -2.97172054 0.70169401 447.25 -4.30028687e+00 4.19566196e-02 4.30049154e+00 3.13183626 0.78069879 447.50 -4.28531275e+00 3.29803378e-01 4.29798507e+00 3.06478273 0.80162138 447.75 -4.22181870e+00 1.02100950e+00 4.34352547e+00 2.90430752 0.84242771 448.00 -3.37349206e+00 1.65565870e+00 3.75787898e+00 2.68534433 0.76596054 448.25 -3.15615729e+00 2.04900699e+00 3.76294545e+00 2.56577341 0.86127884 448.50 -2.99989570e+00 2.30720045e+00 3.78451425e+00 2.48598324 0.85982467 448.75 -2.45838671e+00 2.43339894e+00 3.45905994e+00 2.36130255 0.87722444 449.00 -1.94339190e+00 2.73338372e+00 3.35382746e+00 2.18885608 0.90105952 449.25 -1.76496211e+00 2.72375692e+00 3.24560364e+00 2.14575592 0.92799450 449.50 -1.44753719e+00 2.72415863e+00 3.08486696e+00 2.05922415 0.91744930 449.75 -1.17132013e+00 2.76805126e+00 3.00567774e+00 1.97110486 0.92458841 450.00 -8.81852545e-01 2.66150498e+00 2.80379612e+00 1.89074825 0.88995521 450.25 -7.17688182e-01 2.79669897e+00 2.88731735e+00 1.82199557 0.92367094 450.50 -3.03990687e-01 2.97848403e+00 2.99395682e+00 1.67250636 0.91005847 450.75 2.30751337e-02 3.03313698e+00 3.03322476e+00 1.56318879 0.92454561 451.00 3.78263605e-01 3.04623163e+00 3.06962710e+00 1.44725444 0.91955858 451.25 6.46204173e-01 2.85524517e+00 2.92745706e+00 1.34822415 0.93182749 451.50 8.83006269e-01 2.47583875e+00 2.62858851e+00 1.22821014 0.92055867 451.75 1.00648155e+00 2.36588358e+00 2.57107180e+00 1.16857451 0.92189142 452.00 1.34874008e+00 2.10081107e+00 2.49649894e+00 1.00005905 0.92192335 452.25 1.44545344e+00 1.89762523e+00 2.38543857e+00 0.91983840 0.93285711 452.50 1.58888831e+00 1.65110129e+00 2.29144093e+00 0.80459740 0.93759163 452.75 1.65655793e+00 1.49753408e+00 2.23311273e+00 0.73502255 0.94078220 453.00 1.62129804e+00 1.27431412e+00 2.06215514e+00 0.66613590 0.90137158 453.25 1.58598573e+00 1.02954629e+00 1.89085069e+00 0.57577907 0.90889413 453.50 1.70042867e+00 8.70012285e-01 1.91007305e+00 0.47291850 0.94932940 453.75 1.68223519e+00 8.06954921e-01 1.86576833e+00 0.44726970 0.94944793 454.00 1.62339400e+00 6.66665524e-01 1.75495043e+00 0.38966346 0.95774267 454.25 1.65893706e+00 4.85577603e-01 1.72854210e+00 0.28474990 0.94192002 454.50 1.64789116e+00 1.72171643e-01 1.65686099e+00 0.10410229 0.93671989 454.75 1.57082886e+00 -2.18501495e-03 1.57083038e+00 -0.00139099 0.90529063 455.00 1.21631308e+00 -2.66448879e-01 1.24515562e+00 -0.21565614 0.87606373 455.25 1.04277660e+00 -1.83113033e-01 1.05873198e+00 -0.17382914 0.84016133 455.50 7.79278017e-01 2.49616674e-02 7.79677698e-01 0.03202084 0.81005376 455.75 7.42779002e-01 1.44126267e-01 7.56632690e-01 0.19165494 0.79027837 456.00 7.48335003e-01 3.64428404e-01 8.32354094e-01 0.45318202 0.81161415 456.25 8.45846048e-01 5.14801629e-01 9.90190009e-01 0.54673606 0.77452633 456.50 1.09162061e+00 7.09301884e-01 1.30182362e+00 0.57621323 0.88603550 456.75 1.28298309e+00 8.25800709e-01 1.52577601e+00 0.57190305 0.85574967 457.00 1.65620751e+00 1.06217220e+00 1.96754494e+00 0.57025471 0.89035281 457.25 2.11082056e+00 9.22824340e-01 2.30372920e+00 0.41214811 0.82691209 457.50 2.66802989e+00 2.96339108e-01 2.68443669e+00 0.11061699 0.90088996 457.75 2.72676443e+00 -2.81009029e-01 2.74120600e+00 -0.10269332 0.85354800 458.00 2.75492646e+00 -1.00574359e+00 2.93277002e+00 -0.35003745 0.88111633 458.25 2.41366264e+00 -1.32929499e+00 2.75550222e+00 -0.50340940 0.84161962 458.50 2.02684747e+00 -1.71543487e+00 2.65533942e+00 -0.70237483 0.88720870 458.75 1.50225897e+00 -1.80838800e+00 2.35096771e+00 -0.87760400 0.79837306 459.00 9.94800712e-01 -1.79096825e+00 2.04870587e+00 -1.06377533 0.81741599 459.25 8.34555032e-01 -1.52198031e+00 1.73577250e+00 -1.06923235 0.75987878 459.50 7.51367584e-01 -1.29264102e+00 1.49515017e+00 -1.04426613 0.76075974 459.75 7.51039476e-01 -1.00752959e+00 1.25665276e+00 -0.93022855 0.65361610 460.00 9.35858424e-01 -7.41705358e-01 1.19413476e+00 -0.67017566 0.65960416 460.25 1.60536330e+00 -9.70467353e-01 1.87589931e+00 -0.54373327 0.73575716 460.50 1.83168198e+00 -1.52831404e+00 2.38554033e+00 -0.69535413 0.82776014 460.75 1.20447387e+00 -2.19099120e+00 2.50023993e+00 -1.06815333 0.79002608 461.00 7.64727239e-01 -2.23983248e+00 2.36678205e+00 -1.24178406 0.82460884 461.25 6.63856414e-01 -1.97587892e+00 2.08441906e+00 -1.24666539 0.77181883 461.50 6.29320612e-01 -1.91265483e+00 2.01352748e+00 -1.25292386 0.78276318 461.75 7.30927442e-01 -1.73614087e+00 1.88373036e+00 -1.17231265 0.72345757 462.00 7.69129824e-01 -1.71945558e+00 1.88363696e+00 -1.15018159 0.72791999 462.25 9.32054618e-01 -1.91605735e+00 2.13072795e+00 -1.11805220 0.65307907 462.50 1.06944185e+00 -1.97228680e+00 2.24357329e+00 -1.07393469 0.64742104 462.75 1.50811525e+00 -2.46565653e+00 2.89030685e+00 -1.02185571 0.66180398 463.00 1.57168186e+00 -3.10294023e+00 3.47827859e+00 -1.10195131 0.67712715 463.25 9.79659088e-01 -4.42089432e+00 4.52813853e+00 -1.35272279 0.75338440 463.50 2.80608980e-01 -4.56601493e+00 4.57462935e+00 -1.50941753 0.73945931 463.75 -1.87274769e+00 -3.66171482e+00 4.11282620e+00 -2.04355405 0.71991728 464.00 -2.17757122e+00 -2.97373281e+00 3.68577037e+00 -2.20285244 0.72744363 464.25 -2.32452683e+00 -2.23213474e+00 3.22270856e+00 -2.37646798 0.68136196 464.50 -2.35767995e+00 -1.58784140e+00 2.84251562e+00 -2.54889054 0.64447294 464.75 -1.79272312e+00 -8.83488064e-01 1.99860134e+00 -2.68370631 0.53847733 465.00 -1.35450090e+00 -4.69637473e-01 1.43360805e+00 -2.80783962 0.33163280 465.25 -6.11850010e-01 -4.41771876e-02 6.13442792e-01 -3.06951509 0.14580941 465.50 -8.05266864e-02 -1.30301157e-02 8.15740837e-02 -2.98117195 0.00211181 465.75 1.35531654e+00 8.87606544e-02 1.35821993e+00 0.06539733 0.30732588 466.00 2.38109637e+00 -5.71152618e-01 2.44863947e+00 -0.23542167 0.53963571 466.25 3.27657926e+00 -1.28011507e+00 3.51776438e+00 -0.37245175 0.79671195 466.50 3.85736408e+00 -2.12875834e+00 4.40577686e+00 -0.50427675 0.81036150 466.75 4.26144824e+00 -4.24694899e+00 6.01635412e+00 -0.78369405 0.86224969 467.00 4.26359636e+00 -5.65020234e+00 7.07835011e+00 -0.92436294 0.87869642 467.25 4.29443047e+00 -8.42006251e+00 9.45196200e+00 -1.09916204 0.90587614 467.50 3.23613878e+00 -1.05782148e+01 1.10621527e+01 -1.27391279 0.88855652 467.75 9.73212604e-01 -1.29500012e+01 1.29865189e+01 -1.49578578 0.93401418 468.00 -1.49490972e+00 -1.32606934e+01 1.33446898e+01 -1.68305477 0.90913998 468.25 -4.51107679e+00 -1.33598111e+01 1.41008641e+01 -1.89643601 0.93784695 468.50 -6.59169686e+00 -1.18932405e+01 1.35977806e+01 -2.07688817 0.91649134 468.75 -8.19833984e+00 -1.02950597e+01 1.31605862e+01 -2.24329991 0.93257485 469.00 -8.64418616e+00 -9.85588616e+00 1.31095555e+01 -2.29079087 0.91816373 469.25 -8.85642523e+00 -1.05818880e+01 1.37990080e+01 -2.26766046 0.91754891 469.50 -1.00856529e+01 -1.32770604e+01 1.66733538e+01 -2.22043217 0.91268191 469.75 -1.26943186e+01 -1.42747432e+01 1.91027228e+01 -2.29766004 0.92227493 470.00 -1.81169323e+01 -1.38660352e+01 2.28142536e+01 -2.48833132 0.88914094 470.25 -2.33887671e+01 -1.30064280e+01 2.67619430e+01 -2.63408034 0.90494555 470.50 -2.86637898e+01 -7.90172840e+00 2.97329809e+01 -2.87260426 0.84686971 470.75 -3.42753381e+01 -3.00795685e+00 3.44070720e+01 -3.05405828 0.88458543 471.00 -3.10590277e+01 6.39711804e+00 3.17109811e+01 2.93846675 0.75636316 471.25 -2.77117081e+01 1.48320362e+01 3.14313230e+01 2.65016269 0.75269277 471.50 -2.08124274e+01 2.20748334e+01 3.03390080e+01 2.32676753 0.64897036 471.75 -2.07119583e+01 2.77091484e+01 3.45945389e+01 2.21268093 0.69302436 472.00 -5.98763556e+00 2.67188850e+01 2.73815740e+01 1.79125160 0.53931975 472.25 8.40921174e-01 2.79005767e+01 2.79132464e+01 1.54066553 0.59106599 472.50 9.76865395e+00 1.97357758e+01 2.20210682e+01 1.11117930 0.70670702 472.75 1.31122812e+01 1.73955005e+01 2.17838325e+01 0.92488404 0.81693903 473.00 1.33666805e+01 1.45634330e+01 1.97676941e+01 0.82822008 0.86206508 473.25 1.33163690e+01 1.31940713e+01 1.87459116e+01 0.78078500 0.89989268 473.50 1.29647932e+01 1.04942505e+01 1.66797829e+01 0.68047191 0.90991718 473.75 1.16803001e+01 9.04361384e+00 1.47721482e+01 0.65884890 0.91524457 474.00 1.03585058e+01 6.67945355e+00 1.23253293e+01 0.57273070 0.94797910 474.25 9.85769959e+00 5.92597465e+00 1.15018006e+01 0.54126604 0.95231603 474.50 8.34752437e+00 5.04802867e+00 9.75519127e+00 0.54389284 0.94258425 474.75 7.48495963e+00 4.88544328e+00 8.93824237e+00 0.57827190 0.93367170 475.00 5.75464791e+00 4.96105032e+00 7.59789398e+00 0.71147377 0.91257912 475.25 5.01084341e+00 5.25474590e+00 7.26091634e+00 0.80915292 0.89837194 475.50 5.00991053e+00 6.67257569e+00 8.34400802e+00 0.92676993 0.87892748 475.75 5.32744428e+00 7.06810412e+00 8.85097499e+00 0.92491209 0.87468092 476.00 5.92295581e+00 6.75695181e+00 8.98542171e+00 0.85107660 0.91835014 476.25 6.21622649e+00 6.53406656e+00 9.01861950e+00 0.81032106 0.88673482 476.50 7.43096764e+00 6.21520046e+00 9.68751757e+00 0.69654056 0.89445760 476.75 7.52596480e+00 5.49253835e+00 9.31708773e+00 0.63045501 0.88672797 477.00 7.11294221e+00 4.88147401e+00 8.62686127e+00 0.60145882 0.90022947 477.25 6.14787598e+00 4.45752235e+00 7.59380567e+00 0.62734148 0.85481761 477.50 4.87023584e+00 4.05818665e+00 6.33940660e+00 0.69469668 0.85209432 477.75 3.59275761e+00 4.44306056e+00 5.71390361e+00 0.89081999 0.77423816 478.00 1.83022991e+00 5.86860152e+00 6.14737548e+00 1.26848720 0.83583548 478.25 7.06390930e-02 6.89385088e+00 6.89421278e+00 1.56055000 0.69538226 478.50 -3.04734392e+00 1.01324751e+01 1.05808013e+01 1.86294124 0.61561000 478.75 -3.96879050e+00 7.46913498e+00 8.45808934e+00 2.05921512 0.14830590 479.00 8.28816034e+00 -8.07976113e+00 1.15748063e+01 -0.77266668 0.10927174 479.25 1.77793232e+01 -1.12580766e+01 2.10439688e+01 -0.56448262 0.53945072 479.50 1.86845287e+01 -1.21803233e+01 2.23040778e+01 -0.57770519 0.83093394 479.75 1.56004607e+01 -9.55125422e+00 1.82920975e+01 -0.54937224 0.85648030 480.00 1.42080647e+01 -9.23804097e+00 1.69472860e+01 -0.57651369 0.91774697 480.25 1.29122915e+01 -7.66413389e+00 1.50155326e+01 -0.53566583 0.90321097 480.50 1.29977882e+01 -7.28609318e+00 1.49006594e+01 -0.51091763 0.93323546 480.75 1.32191695e+01 -8.05905129e+00 1.54820784e+01 -0.54748404 0.89207826 481.00 1.37469523e+01 -8.32619379e+00 1.60718450e+01 -0.54458230 0.88804566 481.25 1.31199976e+01 -8.63509835e+00 1.57066630e+01 -0.58209239 0.77944755 481.50 1.39108413e+01 -1.06208270e+01 1.75018134e+01 -0.65208072 0.74241702 481.75 1.01045391e+01 -1.49527375e+01 1.80467745e+01 -0.97652119 0.49455906 482.00 6.12569903e-02 -1.72620857e+01 1.72621944e+01 -1.56724770 0.41558367 482.25 -9.82131531e+00 -1.01421206e+01 1.41181035e+01 -2.34012623 0.65664868 482.50 -7.95061864e+00 -8.90067540e+00 1.19345867e+01 -2.29987525 0.81078252 482.75 -5.78501296e+00 -7.45374962e+00 9.43529323e+00 -2.23080648 0.85745566 483.00 -5.33793737e+00 -7.33485832e+00 9.07158872e+00 -2.19990419 0.89514290 483.25 -4.38158546e+00 -5.74902487e+00 7.22838696e+00 -2.22202447 0.87082064 483.50 -4.37936376e+00 -5.51039650e+00 7.03869991e+00 -2.24232519 0.86055762 483.75 -5.36868734e+00 -4.69725936e+00 7.13351591e+00 -2.42279874 0.85026347 484.00 -5.42712851e+00 -4.16132728e+00 6.83888650e+00 -2.48744857 0.83097563 484.25 -5.74115560e+00 -1.35290206e+00 5.89840755e+00 -2.91016501 0.80263351 484.50 -5.37741078e+00 -6.35443298e-01 5.41482547e+00 -3.02396912 0.85088525 484.75 -3.93662676e+00 6.49132916e-01 3.98978744e+00 2.97816755 0.79676684 485.00 -2.98030310e+00 1.12935033e+00 3.18710507e+00 2.77937390 0.80831054 485.25 -1.77031988e+00 1.36419651e+00 2.23496411e+00 2.48504162 0.84167395 485.50 -1.21591433e+00 1.41066546e+00 1.86237072e+00 2.28218364 0.83404734 485.75 -5.27874310e-01 1.33131353e+00 1.43214769e+00 1.94828734 0.83031931 486.00 -1.37629878e-01 1.22266431e+00 1.23038611e+00 1.68289002 0.78289272 486.25 3.87249658e-01 1.04095241e+00 1.11065036e+00 1.21464542 0.88878440 486.50 4.94061591e-01 9.76310554e-01 1.09420252e+00 1.10232074 0.90072124 486.75 6.77494447e-01 9.49990147e-01 1.16682475e+00 0.95129301 0.88524915 487.00 9.21318166e-01 9.22583084e-01 1.30383538e+00 0.78608416 0.89783753 487.25 1.24489058e+00 9.06643298e-01 1.54005020e+00 0.62946233 0.95401590 487.50 1.41863852e+00 8.62763422e-01 1.66039031e+00 0.54640008 0.95943923 487.75 1.62993793e+00 7.72086909e-01 1.80355644e+00 0.44237976 0.97241590 488.00 1.80051715e+00 6.75783011e-01 1.92316008e+00 0.35905748 0.97542789 488.25 1.91022681e+00 5.15339794e-01 1.97852004e+00 0.26350619 0.98897391 488.50 1.93807617e+00 4.83436149e-01 1.99746083e+00 0.24445271 0.98580579 488.75 1.96631713e+00 4.60670383e-01 2.01955942e+00 0.23013031 0.98812427 489.00 2.11148983e+00 4.78770957e-01 2.16508913e+00 0.22297528 0.98136176 489.25 2.28112125e+00 4.11108729e-01 2.31787069e+00 0.17830817 0.98791533 489.50 2.24100553e+00 3.04081809e-01 2.26154184e+00 0.13486621 0.98582711 489.75 2.19445282e+00 3.03737066e-01 2.21537342e+00 0.13753744 0.98987506 490.00 2.19953782e+00 4.07174960e-01 2.23690815e+00 0.18304626 0.98478547 490.25 2.21604308e+00 4.81496930e-01 2.26774915e+00 0.21395228 0.98177342 490.50 2.40761659e+00 5.83129542e-01 2.47722783e+00 0.23762601 0.97738032 490.75 2.47726858e+00 6.58715874e-01 2.56335059e+00 0.25989032 0.98616004 491.00 2.55884896e+00 6.88614939e-01 2.64988652e+00 0.26288325 0.98026970 491.25 2.68772687e+00 7.72781599e-01 2.79661708e+00 0.27997048 0.98482226 491.50 2.98914324e+00 9.66919644e-01 3.14164143e+00 0.31285395 0.97959803 491.75 3.17545014e+00 9.84163581e-01 3.32446410e+00 0.30054075 0.98840800 492.00 3.35940292e+00 8.48648198e-01 3.46493748e+00 0.24744186 0.98382045 492.25 3.46514376e+00 7.73087639e-01 3.55033601e+00 0.21950913 0.98629720 492.50 3.53788202e+00 6.95328603e-01 3.60556390e+00 0.19406460 0.98572940 492.75 3.55321909e+00 6.88400570e-01 3.61929016e+00 0.19136912 0.98556656 493.00 3.50107610e+00 7.61240855e-01 3.58287894e+00 0.21409815 0.97272666 493.25 3.53682179e+00 9.48982996e-01 3.66192260e+00 0.26214083 0.96924312 493.50 3.80032084e+00 1.28140648e+00 4.01054124e+00 0.32521193 0.95881145 493.75 4.10262757e+00 1.36937183e+00 4.32512800e+00 0.32215180 0.96015129 494.00 5.07747411e+00 1.36887389e+00 5.25876022e+00 0.26333657 0.96557199 494.25 5.39001436e+00 1.25205302e+00 5.53352434e+00 0.22824340 0.96009194 494.50 5.58537818e+00 5.26974636e-01 5.61018285e+00 0.09407049 0.93225625 494.75 5.68067094e+00 7.95222411e-02 5.68122752e+00 0.01399783 0.93772149 495.00 5.52384968e+00 -5.42709627e-01 5.55044584e+00 -0.09793414 0.95499346 495.25 5.31014724e+00 -8.10733919e-01 5.37168067e+00 -0.15150638 0.94610902 495.50 5.13657872e+00 -1.23711490e+00 5.28345476e+00 -0.23634300 0.92036285 495.75 4.82958220e+00 -1.29318358e+00 4.99971879e+00 -0.26162569 0.90656994 496.00 4.25982802e+00 -1.56057779e+00 4.53668798e+00 -0.35116352 0.89192127 496.25 3.78816953e+00 -1.16523687e+00 3.96333261e+00 -0.29841362 0.82909201 496.50 3.05267213e+00 -4.82250566e-01 3.09052953e+00 -0.15668168 0.85407289 496.75 2.93297776e+00 -1.88905713e-01 2.93905493e+00 -0.06431864 0.82929532 497.00 2.86474896e+00 8.42946676e-01 2.98619251e+00 0.28617142 0.84755116 497.25 2.86552086e+00 1.40414788e+00 3.19105642e+00 0.45562766 0.84165456 497.50 3.04241206e+00 2.35520085e+00 3.84749818e+00 0.65876186 0.88161992 497.75 3.48063428e+00 2.77631322e+00 4.45227246e+00 0.67330379 0.85415350 498.00 3.97509261e+00 3.97947631e+00 5.62473048e+00 0.78594926 0.93263954 498.25 4.18559541e+00 4.32518587e+00 6.01884056e+00 0.80179830 0.90569433 498.50 4.86280933e+00 5.42776432e+00 7.28749203e+00 0.84024335 0.92748974 498.75 5.65163191e+00 5.80405398e+00 8.10111016e+00 0.79870274 0.92483119 499.00 6.85506463e+00 6.52704858e+00 9.46542520e+00 0.76089154 0.94398988 499.25 7.23621401e+00 6.93031563e+00 1.00195842e+01 0.76380848 0.92816110 499.50 7.96532616e+00 7.60819101e+00 1.10150348e+01 0.76246997 0.93403548 499.75 8.97226801e+00 8.15169281e+00 1.21223632e+01 0.73751508 0.92382659 500.00 9.68220068e+00 9.24719309e+00 1.33886366e+01 0.76242167 0.94105130 500.25 1.09600196e+01 9.47242993e+00 1.44861644e+01 0.71272114 0.94127190 500.50 1.17020007e+01 9.39495398e+00 1.50067312e+01 0.67647647 0.94518316 500.75 1.02508897e+01 1.15170277e+01 1.54182575e+01 0.84349803 0.88614726 501.00 8.29584072e+00 1.50262781e+01 1.71642071e+01 1.06635080 0.90729447 501.25 6.19226436e+00 2.05903537e+01 2.15013209e+01 1.27866427 0.77842014 501.50 4.17375015e+00 2.70203083e+01 2.73407617e+01 1.41754041 0.76955017 501.75 -7.74825396e+00 2.79145391e+01 2.89699315e+01 1.84155078 0.44945106 502.00 -2.02843941e+01 1.90023803e+01 2.77947315e+01 2.38881511 0.26372742 502.25 -2.66138953e+01 7.91157717e+00 2.77649505e+01 2.85264010 0.29954208 502.50 -2.87578449e+01 -7.58704464e+00 2.97418374e+01 -2.88364494 0.35776801 502.75 -2.30998488e+01 -1.45837801e+01 2.73183026e+01 -2.57844965 0.49631154 503.00 -2.18197825e+01 -1.33482243e+01 2.55788585e+01 -2.59257914 0.59390812 503.25 -1.45255476e+01 -1.22196971e+01 1.89819001e+01 -2.44219716 0.67065333 503.50 -1.33773653e+01 -1.22136164e+01 1.81142576e+01 -2.40163814 0.75401858 503.75 -6.88589254e+00 -1.02017508e+01 1.23081776e+01 -2.16452652 0.64106194 504.00 -5.20569239e+00 -9.68659772e+00 1.09967908e+01 -2.06392359 0.69439043 504.25 -1.83993970e+00 -7.83216925e+00 8.04538708e+00 -1.80153326 0.67072704 504.50 -2.11815299e-01 -8.04305213e+00 8.04584075e+00 -1.59712543 0.72814168 504.75 1.25814540e+00 -9.18618325e+00 9.27194114e+00 -1.43468257 0.76288511 505.00 2.09680355e+00 -8.10796561e+00 8.37470545e+00 -1.31773040 0.71943093 505.25 3.58707044e+00 -6.00724003e+00 6.99671402e+00 -1.03249382 0.54810778 505.50 5.90293728e+00 -5.02928770e+00 7.75489544e+00 -0.70565256 0.63913754 505.75 8.76467126e+00 -4.10338842e+00 9.67766804e+00 -0.43786396 0.76677689 506.00 1.15085168e+01 -4.20932429e+00 1.22541572e+01 -0.35064298 0.82330958 506.25 1.51796854e+01 -4.27841013e+00 1.57711015e+01 -0.27472435 0.82681879 506.50 1.94206451e+01 -5.70603187e+00 2.02415478e+01 -0.28577074 0.85087732 506.75 2.43736232e+01 -1.09702164e+01 2.67286205e+01 -0.42292509 0.93138543 507.00 2.55530061e+01 -1.40425119e+01 2.91573020e+01 -0.50249337 0.91182487 507.25 2.64844340e+01 -2.16003422e+01 3.41760154e+01 -0.68417280 0.93859934 507.50 2.81022872e+01 -2.32764683e+01 3.64901702e+01 -0.69174657 0.91411816 507.75 3.35906591e+01 -3.08408340e+01 4.56014190e+01 -0.74274577 0.94798220 508.00 3.32377264e+01 -3.85038237e+01 5.08654195e+01 -0.85867048 0.94544340 508.25 3.00123468e+01 -5.29623587e+01 6.08748914e+01 -1.05524241 0.95957039 508.50 2.49109012e+01 -6.20359858e+01 6.68507033e+01 -1.18894958 0.95779632 508.75 1.74140069e+01 -6.83802837e+01 7.05628148e+01 -1.32143272 0.96042805 509.00 1.53635989e+00 -7.05349508e+01 7.05516810e+01 -1.54901823 0.91774698 509.25 -1.57912394e+01 -7.34935606e+01 7.51709166e+01 -1.78244404 0.95727721 509.50 -2.97177238e+01 -6.65900476e+01 7.29203507e+01 -1.99055136 0.95125254 509.75 -4.23179266e+01 -5.45127029e+01 6.90104462e+01 -2.23091481 0.97327996 510.00 -4.57139009e+01 -4.37562628e+01 6.32801017e+01 -2.37807135 0.94811138 510.25 -4.36831764e+01 -3.11251486e+01 5.36376246e+01 -2.52251316 0.96036389 510.50 -4.09148813e+01 -2.04038591e+01 4.57202907e+01 -2.67899326 0.91429848 510.75 -3.59953514e+01 -1.38472663e+01 3.85669820e+01 -2.77434863 0.95215979 511.00 -3.06443995e+01 -1.07692705e+01 3.24816318e+01 -2.80364710 0.95674451 511.25 -2.72763461e+01 -9.52771253e+00 2.88924966e+01 -2.80553881 0.97388304 511.50 -2.47377412e+01 -1.00740336e+01 2.67103350e+01 -2.75486621 0.97494942 511.75 -2.36108783e+01 -9.94305367e+00 2.56190923e+01 -2.74301153 0.97415768 512.00 -2.26255215e+01 -7.82281078e+00 2.39397283e+01 -2.80870758 0.95831786 512.25 -2.15645885e+01 -5.96857815e+00 2.23753302e+01 -2.87157530 0.96856533 512.50 -1.93262394e+01 -4.18020875e+00 1.97731554e+01 -2.92857707 0.96402238 512.75 -1.67645725e+01 -4.13940888e+00 1.72680513e+01 -2.89952049 0.95094465 513.00 -1.29029420e+01 -4.57602116e+00 1.36903573e+01 -2.80078181 0.93438882 513.25 -1.16698502e+01 -4.86854235e+00 1.26446870e+01 -2.74635588 0.94390691 513.50 -8.55956578e+00 -6.81132231e+00 1.09389340e+01 -2.46944513 0.88014704 513.75 -6.76849388e+00 -7.84353939e+00 1.03601940e+01 -2.28275419 0.90993320 514.00 -5.39608897e+00 -8.24430012e+00 9.85323605e+00 -2.15034501 0.87308762 514.25 -3.90113930e+00 -9.06624291e+00 9.86993659e+00 -1.97714149 0.86052819 514.50 -2.04597417e+00 -1.12006198e+01 1.13859516e+01 -1.75147054 0.86932867 514.75 -1.08908883e+00 -1.28026863e+01 1.28489257e+01 -1.65565923 0.88548284 515.00 1.42791422e+00 -1.54012065e+01 1.54672590e+01 -1.47834618 0.83693228 515.25 3.45571397e+00 -1.89421441e+01 1.92547859e+01 -1.39034561 0.85169431 515.50 5.01963831e+00 -2.54868929e+01 2.59764986e+01 -1.37633537 0.88653019 515.75 4.55131864e+00 -3.02136114e+01 3.05544893e+01 -1.42128246 0.90007137 516.00 1.41834600e+00 -3.65936200e+01 3.66210967e+01 -1.53205634 0.87673523 516.25 9.20724169e-01 -3.97276926e+01 3.97383605e+01 -1.54762460 0.78864591 516.50 -1.20111346e+00 -4.60872252e+01 4.61028741e+01 -1.59685217 0.55083794 516.75 -9.02692219e-01 -2.95509532e+01 2.95647372e+01 -1.60133381 0.21552957 517.00 -1.69503648e+01 7.75202032e+00 1.86389025e+01 2.71265448 0.19876935 517.25 -1.79012884e+01 8.93292838e-01 1.79235627e+01 3.09173298 0.38474038 517.50 -2.07166763e+01 -7.15136928e+00 2.19162670e+01 -2.80920157 0.64882249 517.75 -2.46378998e+01 -1.04443897e+01 2.67602575e+01 -2.74064087 0.78659629 518.00 -2.97274688e+01 -1.34799669e+01 3.26409545e+01 -2.71587212 0.84470556 518.25 -2.99075881e+01 -8.73919673e+00 3.11582635e+01 -2.85730095 0.80218168 518.50 -2.60978935e+01 -1.39695335e+00 2.61352544e+01 -3.08811625 0.83660396 518.75 -2.27059513e+01 -8.92532414e-01 2.27234865e+01 -3.10230458 0.81852014 519.00 -1.83004802e+01 -2.82879403e+00 1.85178198e+01 -2.98823155 0.78617609 519.25 -1.66456449e+01 -3.55410230e+00 1.70208442e+01 -2.93123589 0.80632891 519.50 -1.71515046e+01 -3.72325162e+00 1.75509747e+01 -2.92782908 0.83597588 519.75 -1.56801652e+01 -3.29120377e+00 1.60218477e+01 -2.93470008 0.83516261 520.00 -1.47954097e+01 -2.40180692e+00 1.49890902e+01 -2.98066190 0.85090546 520.25 -1.19871807e+01 -1.07709337e+00 1.20354738e+01 -3.05197954 0.77133030 520.50 -8.32055072e+00 -2.22247739e-01 8.32351839e+00 -3.11488830 0.72455037 520.75 -5.06799583e+00 -1.50683174e+00 5.28726050e+00 -2.85259363 0.57212008 521.00 -2.45093891e+00 -2.66169458e+00 3.61824814e+00 -2.31499529 0.48325340 521.25 2.43644983e-01 -3.14672782e+00 3.15614621e+00 -1.49352246 0.33180626 521.50 2.51856241e+00 -3.02706992e+00 3.93780509e+00 -0.87683760 0.48650087 521.75 5.24120297e+00 -3.80201971e+00 6.47499517e+00 -0.62757672 0.61662668 522.00 7.77862909e+00 -4.66761011e+00 9.07158502e+00 -0.54046040 0.82910817 522.25 9.50888772e+00 -4.81287735e+00 1.06575201e+01 -0.46855163 0.84528366 522.50 1.07171252e+01 -6.13530646e+00 1.23490388e+01 -0.51993602 0.88347356 522.75 1.08448664e+01 -8.30109627e+00 1.36572079e+01 -0.65330980 0.92441349 523.00 1.09157711e+01 -9.24042553e+00 1.43017315e+01 -0.70247064 0.95762434 523.25 9.84703432e+00 -1.10301156e+01 1.47860588e+01 -0.84200634 0.92077023 523.50 7.93175190e+00 -1.22209097e+01 1.45692595e+01 -0.99510245 0.93955271 523.75 6.14399167e+00 -1.07444453e+01 1.23770650e+01 -1.05134796 0.95995032 524.00 5.76803520e+00 -1.01800948e+01 1.17006222e+01 -1.05529827 0.97134123 524.25 5.04237580e+00 -9.50209587e+00 1.07571083e+01 -1.08292315 0.96184224 524.50 4.35763047e+00 -9.32669958e+00 1.02944776e+01 -1.13371401 0.96790188 524.75 2.53463010e+00 -9.68037567e+00 1.00066989e+01 -1.31471323 0.95292253 525.00 1.28116087e+00 -9.28050356e+00 9.36851747e+00 -1.43361475 0.94474469 525.25 -1.03025989e+00 -8.20806685e+00 8.27247223e+00 -1.69566129 0.93554147 525.50 -1.97216660e+00 -7.55441911e+00 7.80760458e+00 -1.82615824 0.93432248 525.75 -3.03972443e+00 -5.42634183e+00 6.21973555e+00 -2.08142114 0.88564754 526.00 -3.82468019e+00 -4.10677028e+00 5.61192843e+00 -2.32064346 0.87092202 526.25 -4.13795865e+00 -1.56799977e+00 4.42507911e+00 -2.77938031 0.81616275 526.50 -3.87959070e+00 -5.06736575e-01 3.91254469e+00 -3.01171195 0.83858991 526.75 -3.03757005e+00 9.59801366e-01 3.18560049e+00 2.83554354 0.75339893 527.00 -2.16810969e+00 1.68146761e+00 2.74372611e+00 2.48194190 0.72770289 527.25 -1.46264046e+00 1.59454351e+00 2.16376665e+00 2.31307595 0.76699317 527.50 -1.32819685e+00 1.85133123e+00 2.27849384e+00 2.19312342 0.76120155 527.75 -8.58390760e-01 2.65716626e+00 2.79237662e+00 1.88326119 0.76764623 528.00 -3.32090600e-01 2.61003175e+00 2.63107391e+00 1.69735254 0.76154603 528.25 3.52303300e-01 2.72271957e+00 2.74541790e+00 1.44211740 0.76715219 528.50 8.08218873e-01 2.52425668e+00 2.65048854e+00 1.26092926 0.76610240 528.75 9.56309255e-01 1.87201244e+00 2.10213177e+00 1.09850996 0.75899150 529.00 8.86304464e-01 1.72197643e+00 1.93668233e+00 1.09545653 0.70046453 529.25 7.89725576e-01 1.51580909e+00 1.70919387e+00 1.09049589 0.73305528 529.50 7.04145426e-01 1.52824018e+00 1.68265827e+00 1.13903402 0.67254836 529.75 5.42601369e-01 1.55734188e+00 1.64916038e+00 1.23553417 0.77403775 530.00 6.45191411e-01 1.65721189e+00 1.77837656e+00 1.19952764 0.70731354 530.25 9.20381670e-01 1.60762543e+00 1.85244755e+00 1.05083534 0.70918167 530.50 9.33148844e-01 1.56657183e+00 1.82343469e+00 1.03357191 0.69112132 530.75 9.33662591e-01 1.54635604e+00 1.80636176e+00 1.02760027 0.72266627 531.00 1.11547364e+00 1.32410180e+00 1.73133677e+00 0.87070882 0.56415321 531.25 1.26592411e+00 1.03377554e+00 1.63439766e+00 0.68479163 0.56855048 531.50 1.06633380e+00 1.09633793e+00 1.52938701e+00 0.79927092 0.45352280 531.75 1.04297304e+00 9.30428150e-01 1.39767282e+00 0.72842895 0.43155022 532.00 8.05025508e-01 6.95153763e-01 1.06362814e+00 0.71228962 0.23149123 532.25 3.94661104e-01 3.99294115e-01 5.61420677e-01 0.79123345 0.08513890 532.50 2.32609745e-01 3.26332948e-01 4.00749905e-01 0.95153209 0.02444163 532.75 -2.31796850e-02 1.40979719e-01 1.42872597e-01 1.73375688 0.00371398 533.00 -5.31134438e-01 2.28868422e-01 5.78346389e-01 2.73473117 0.04589979 533.25 -7.11091534e-01 6.36385927e-01 9.54273660e-01 2.41157887 0.13771361 533.50 -2.93284510e-01 9.13847455e-01 9.59756727e-01 1.88134608 0.09305128 533.75 -1.24950632e-01 1.30590841e+00 1.31187249e+00 1.66618695 0.17381472 534.00 -3.75052462e-01 1.84048158e+00 1.87830689e+00 1.77182339 0.24523215 534.25 -2.84068207e-01 2.40301603e+00 2.41974808e+00 1.68846344 0.41409803 534.50 -2.10808757e-02 2.12364990e+00 2.12375453e+00 1.58072272 0.29607944 534.75 3.75635951e-01 1.95577061e+00 1.99151728e+00 1.38104166 0.30020751 535.00 2.06656566e-01 2.44695546e+00 2.45566650e+00 1.48654170 0.37559118 535.25 2.36365973e-02 2.71674201e+00 2.71684483e+00 1.56209620 0.40947437 535.50 1.08915775e+00 3.56931916e+00 3.73179634e+00 1.27462661 0.47259500 535.75 1.63243236e+00 3.76340602e+00 4.10220188e+00 1.16152546 0.51451242 536.00 1.61475862e+00 3.32701484e+00 3.69817160e+00 1.11893921 0.46445829 536.25 1.84242195e+00 3.23866272e+00 3.72605084e+00 1.05357087 0.46461272 536.50 2.74220529e+00 3.15038475e+00 4.17667499e+00 0.85455765 0.47008646 536.75 2.93713770e+00 3.32384572e+00 4.43562039e+00 0.84708454 0.48373660 537.00 2.78651904e+00 3.55055527e+00 4.51343894e+00 0.90538510 0.25038578 537.25 2.47723433e+00 3.42669580e+00 4.22834885e+00 0.94485144 0.14650006 537.50 4.55951183e+00 -4.58438296e-01 4.58250082e+00 -0.10020870 0.12504711 537.75 6.33287402e+00 -2.32226007e+00 6.74523426e+00 -0.35147350 0.24076966 538.00 7.25945495e+00 -2.68949492e+00 7.74164512e+00 -0.35480351 0.41378120 538.25 7.42071574e+00 -2.48791305e+00 7.82666810e+00 -0.32348887 0.38082996 538.50 7.54312616e+00 -5.07358330e+00 9.09065453e+00 -0.59210605 0.41023521 538.75 5.13689498e+00 -5.82680968e+00 7.76784404e+00 -0.84824245 0.28984421 539.00 3.84338380e-01 -9.77314162e+00 9.78069594e+00 -1.53149060 0.30101784 539.25 -4.36981970e+00 -9.89234772e+00 1.08145211e+01 -1.98675784 0.34574163 539.50 -9.26327529e+00 -7.80016147e+00 1.21099458e+01 -2.44173082 0.60304538 539.75 -9.07494844e+00 -5.98243662e+00 1.08694175e+01 -2.55875940 0.63448298 540.00 -7.96216573e+00 -2.98909914e+00 8.50475142e+00 -2.78246010 0.68103529 540.25 -6.78858086e+00 -1.15044527e+00 6.88537250e+00 -2.97371988 0.72978994 540.50 -5.57880242e+00 -6.77721185e-02 5.57921406e+00 -3.12944510 0.71863855 540.75 -3.82957792e+00 2.10644269e-01 3.83536675e+00 3.08664346 0.53134520 541.00 -2.39122573e+00 -3.61276360e-01 2.41836331e+00 -2.99164256 0.45049814 541.25 -1.48610897e+00 -7.90981787e-01 1.68349994e+00 -2.65247898 0.29329528 541.50 -9.19371816e-01 -9.48230698e-01 1.32075206e+00 -2.34074335 0.31210039 541.75 -4.38499963e-01 -1.58631039e+00 1.64580159e+00 -1.84048927 0.35743463 542.00 1.62456188e-01 -2.53985291e+00 2.54504318e+00 -1.50692051 0.64384679 542.25 7.07723088e-01 -3.82266714e+00 3.88762859e+00 -1.38773059 0.74381735 542.50 8.95029583e-01 -5.24082011e+00 5.31669760e+00 -1.40164775 0.84986799 542.75 -5.30534562e-01 -6.52700662e+00 6.54853284e+00 -1.65190100 0.80880357 543.00 -2.20510279e+00 -6.83884779e+00 7.18556312e+00 -1.88270903 0.87682329 543.25 -4.00540727e+00 -5.99063430e+00 7.20631575e+00 -2.16014418 0.89969771 543.50 -4.52819754e+00 -5.23158537e+00 6.91910821e+00 -2.28424885 0.93931446 543.75 -4.21805289e+00 -4.31550256e+00 6.03452836e+00 -2.34477540 0.91724859 544.00 -3.82246065e+00 -3.87999074e+00 5.44660752e+00 -2.34872557 0.92667499 544.25 -3.50759893e+00 -4.11019959e+00 5.40342400e+00 -2.27725457 0.90863485 544.50 -3.50230598e+00 -4.46291006e+00 5.67306913e+00 -2.23617424 0.93832020 544.75 -3.64909350e+00 -4.98330882e+00 6.17650792e+00 -2.20284889 0.93478646 545.00 -3.73688615e+00 -5.29724818e+00 6.48268127e+00 -2.18516339 0.94617754 545.25 -4.41766261e+00 -5.37948571e+00 6.96093453e+00 -2.25833430 0.90211314 545.50 -5.42177684e+00 -5.35627166e+00 7.62137194e+00 -2.36227206 0.90786369 545.75 -6.25046819e+00 -4.71753670e+00 7.83093258e+00 -2.49505889 0.92046834 546.00 -6.44555012e+00 -4.08866541e+00 7.63297459e+00 -2.57630565 0.92700518 546.25 -6.30122539e+00 -2.63194288e+00 6.82880405e+00 -2.74593205 0.92316131 546.50 -6.20652778e+00 -2.30997035e+00 6.62245801e+00 -2.78529309 0.92600558 546.75 -5.39077891e+00 -2.12452656e+00 5.79431707e+00 -2.76617950 0.82307108 547.00 -5.46914771e+00 -1.63049976e+00 5.70702253e+00 -2.85185523 0.84623357 547.25 -5.45268717e+00 -8.11736178e-01 5.51277725e+00 -2.99380899 0.90852962 547.50 -5.00986670e+00 -5.88729239e-01 5.04434005e+00 -3.02461520 0.91607971 547.75 -4.30795859e+00 -3.94320576e-01 4.32596763e+00 -3.05031396 0.92962278 548.00 -4.02908058e+00 -3.71731712e-01 4.04619263e+00 -3.04959094 0.90895741 548.25 -3.27343691e+00 -7.62675189e-01 3.36111033e+00 -2.91268718 0.91176858 548.50 -3.09097317e+00 -8.56996530e-01 3.20757825e+00 -2.87112857 0.91557802 548.75 -2.90281661e+00 -9.53341374e-01 3.05535661e+00 -2.82427111 0.93799487 549.00 -2.80573074e+00 -9.85672493e-01 2.97383174e+00 -2.80375406 0.93583418 549.25 -2.58009135e+00 -1.03010486e+00 2.77812660e+00 -2.76173186 0.93358039 549.50 -2.50933927e+00 -1.11165721e+00 2.74455193e+00 -2.72456852 0.91281222 549.75 -2.40135437e+00 -1.22023138e+00 2.69359749e+00 -2.67145190 0.92673851 550.00 -2.25013500e+00 -1.21534943e+00 2.55737791e+00 -2.64636425 0.89463475 550.25 -1.89802775e+00 -1.06744082e+00 2.17759942e+00 -2.62928316 0.86975995 550.50 -1.77362703e+00 -1.03134050e+00 2.05168615e+00 -2.61489712 0.81263571 550.75 -1.30947983e+00 -1.10924496e+00 1.71614737e+00 -2.43879145 0.66078033 551.00 -9.79672500e-01 -1.32523932e+00 1.64803442e+00 -2.20737666 0.56165959 551.25 -7.93170265e-01 -1.81366568e+00 1.97952071e+00 -1.98306400 0.72151453 551.50 -7.32708431e-01 -2.11735480e+00 2.24054748e+00 -1.90394696 0.70887780 551.75 -5.59705401e-01 -2.49283184e+00 2.55489348e+00 -1.79165950 0.77288533 552.00 -5.74231795e-01 -2.45650580e+00 2.52272926e+00 -1.80043247 0.69809809 552.25 -3.71310139e-01 -2.45286865e+00 2.48081354e+00 -1.72103359 0.69702112 552.50 -4.48828060e-01 -2.78788390e+00 2.82378173e+00 -1.73041905 0.66763397 552.75 -4.63423347e-01 -3.12178379e+00 3.15599355e+00 -1.71816833 0.77958654 553.00 -5.97140753e-01 -3.30088337e+00 3.35446093e+00 -1.74976410 0.71420834 553.25 -6.55150456e-01 -3.43211195e+00 3.49408279e+00 -1.75941561 0.75325560 553.50 -7.23813294e-01 -2.99232687e+00 3.07862401e+00 -1.80812740 0.61938439 553.75 -9.30171294e-01 -2.63102559e+00 2.79061182e+00 -1.91062083 0.59803635 554.00 -3.76362516e-01 -2.31839805e+00 2.34874823e+00 -1.73172973 0.43500925 554.25 -1.17045153e-01 -2.08441066e+00 2.08769427e+00 -1.62689006 0.37552612 554.50 5.06516142e-01 -1.53156356e+00 1.61314772e+00 -1.25140112 0.18136616 554.75 1.52436588e+00 -1.24425381e+00 1.96770396e+00 -0.68456736 0.26203423 555.00 2.46856604e+00 -1.79416262e+00 3.05169425e+00 -0.62848937 0.33898213 555.25 3.89832790e+00 -1.95376591e+00 4.36052310e+00 -0.46459156 0.40319095 555.50 3.57055514e+00 -2.07857679e+00 4.13150644e+00 -0.52718652 0.25080977 555.75 3.54934829e+00 -1.91066728e+00 4.03094564e+00 -0.49382773 0.18338410 556.00 2.83958115e+00 -2.75382923e+00 3.95560318e+00 -0.77006848 0.15118096 556.25 3.16204294e+00 -9.38022882e-01 3.29824233e+00 -0.28838140 0.11499719 556.50 -1.02161965e+00 2.86934257e+00 3.04578947e+00 1.91284768 0.10670294 556.75 -2.22429147e+00 3.85790853e+00 4.45319332e+00 2.09379747 0.29707057 557.00 -3.21873147e+00 2.71425536e+00 4.21039362e+00 2.44101949 0.52523422 557.25 -3.35692462e+00 2.49441843e+00 4.18223221e+00 2.50254373 0.61766195 557.50 -3.11477146e+00 2.05222465e+00 3.73007068e+00 2.55900826 0.62198061 557.75 -2.73140864e+00 1.41425284e+00 3.07582578e+00 2.66382703 0.59378653 558.00 -2.83986599e+00 1.01339999e+00 3.01526423e+00 2.79883040 0.75262940 558.25 -2.59336203e+00 8.46432754e-01 2.72799835e+00 2.82610918 0.71266718 558.50 -2.31603509e+00 4.35951329e-01 2.35670789e+00 2.95553790 0.74648861 558.75 -2.27052392e+00 4.45623258e-01 2.31384074e+00 2.94779148 0.68418757 559.00 -1.76383517e+00 2.39338769e-02 1.76399754e+00 3.12802426 0.60699582 559.25 -1.70192966e+00 -9.03349814e-02 1.70432538e+00 -3.08856444 0.56029328 559.50 -1.40559088e+00 -1.95542730e-01 1.41912743e+00 -3.00336204 0.43618620 559.75 -1.42933646e+00 -6.25499414e-01 1.56020904e+00 -2.72908549 0.42636879 560.00 -8.39682044e-01 -1.01910272e+00 1.32046821e+00 -2.25996682 0.46596150 560.25 -6.14486474e-01 -1.20114178e+00 1.34919798e+00 -2.04366916 0.42377928 560.50 -8.13187920e-01 -1.60729898e+00 1.80130081e+00 -2.03918022 0.64415722 560.75 -6.66175427e-01 -1.70098964e+00 1.82678829e+00 -1.94407502 0.62734121 561.00 -6.92553689e-01 -1.79048334e+00 1.91975551e+00 -1.93986930 0.70680609 561.25 -8.10175843e-01 -1.74945852e+00 1.92794969e+00 -2.00449141 0.61262933 561.50 -8.71751931e-01 -1.66795642e+00 1.88202818e+00 -2.05239673 0.70823993 561.75 -7.93391218e-01 -1.58671290e+00 1.77401450e+00 -2.03446146 0.66525960 562.00 -7.77377924e-01 -1.44756640e+00 1.64309614e+00 -2.06362262 0.68674557 562.25 -7.63603612e-01 -1.41962456e+00 1.61196290e+00 -2.06429548 0.64037278 562.50 -7.90650354e-01 -1.13738420e+00 1.38519703e+00 -2.17825849 0.58992971 562.75 -3.69545477e-01 -6.88795643e-01 7.81666999e-01 -2.06322327 0.32946769 563.00 9.36046289e-03 -5.14487871e-01 5.14573015e-01 -1.55260459 0.24969759 563.25 2.35223024e-01 -3.91362050e-01 4.56611569e-01 -1.02961477 0.19248556 563.50 4.78749319e-01 -3.38461926e-01 5.86308268e-01 -0.61538924 0.32485088 563.75 9.25549325e-01 -3.48289359e-01 9.88912044e-01 -0.35991478 0.45497668 564.00 1.33896700e+00 -3.05756797e-01 1.37343360e+00 -0.22450334 0.65107403 564.25 1.79568944e+00 -6.28849282e-01 1.90261714e+00 -0.33685241 0.80472292 564.50 1.92999027e+00 -7.39496068e-01 2.06681322e+00 -0.36590583 0.88031675 564.75 2.20987206e+00 -9.86114481e-01 2.41990832e+00 -0.41971561 0.90907989 565.00 2.44798183e+00 -1.13656590e+00 2.69896222e+00 -0.43467119 0.93658289 565.25 2.36219278e+00 -1.58265036e+00 2.84336717e+00 -0.59030125 0.93570145 565.50 2.28721211e+00 -1.74975892e+00 2.87975615e+00 -0.65304368 0.94588994 565.75 2.23276243e+00 -2.05725671e+00 3.03603907e+00 -0.74451072 0.94114416 566.00 2.03885317e+00 -2.21444444e+00 3.01009741e+00 -0.82665829 0.94160558 566.25 1.57610139e+00 -2.15348065e+00 2.66862783e+00 -0.93898961 0.90398638 566.50 1.45539219e+00 -1.99648727e+00 2.47065333e+00 -0.94088662 0.90860300 566.75 1.61398830e+00 -1.94938707e+00 2.53082362e+00 -0.87924557 0.92817399 567.00 1.62781058e+00 -1.89930849e+00 2.50142760e+00 -0.86222109 0.93458600 567.25 1.38318312e+00 -1.74106063e+00 2.22362039e+00 -0.89944959 0.91248332 567.50 1.30035214e+00 -1.71920286e+00 2.15559137e+00 -0.92323136 0.89779998 567.75 1.30598279e+00 -1.76286394e+00 2.19391894e+00 -0.93318979 0.90849751 568.00 1.25412440e+00 -1.72223795e+00 2.13047684e+00 -0.94139734 0.90875888 568.25 1.08700258e+00 -1.63990485e+00 1.96745077e+00 -0.98544422 0.89450455 568.50 1.04990480e+00 -1.55318446e+00 1.87474853e+00 -0.97638115 0.87702260 568.75 1.26986762e+00 -1.21623889e+00 1.75835174e+00 -0.76383014 0.79581734 569.00 1.40332569e+00 -1.20427445e+00 1.84921604e+00 -0.70921089 0.78560101 569.25 1.46020349e+00 -1.51984889e+00 2.10763727e+00 -0.80541038 0.83031608 569.50 1.47419686e+00 -1.58303628e+00 2.16315978e+00 -0.82098376 0.75421017 569.75 1.28346711e+00 -2.28336409e+00 2.61935858e+00 -1.05871472 0.77920418 570.00 1.04436891e+00 -2.37866666e+00 2.59783785e+00 -1.15708024 0.77875690 570.25 3.16627930e-01 -2.44547976e+00 2.46589223e+00 -1.44203786 0.76914208 570.50 3.76736959e-02 -2.26959821e+00 2.26991087e+00 -1.55419857 0.67617083 570.75 -4.94906412e-01 -1.55473747e+00 1.63160687e+00 -1.87897597 0.55434753 571.00 -5.29971419e-01 -8.53286322e-01 1.00447362e+00 -2.12658224 0.21109159 571.25 4.16805806e-02 -2.50934832e-01 2.54372877e-01 -1.40619787 0.01239604 571.50 6.72059361e-01 1.95439377e-01 6.99900232e-01 0.28300140 0.07996121 571.75 1.50810617e+00 4.83307219e-01 1.58365719e+00 0.31013190 0.31413724 572.00 2.04758648e+00 3.74452044e-01 2.08154383e+00 0.18087615 0.44397855 572.25 2.34465949e+00 1.06713518e-01 2.34708668e+00 0.04548205 0.57830669 572.50 3.04717740e+00 -6.20381645e-01 3.10968865e+00 -0.20084723 0.58768485 572.75 3.46843307e+00 -1.72002132e+00 3.87149859e+00 -0.46036810 0.69266077 573.00 3.34136927e+00 -2.89610158e+00 4.42178165e+00 -0.71413312 0.75224032 573.25 3.20242850e+00 -3.88287683e+00 5.03311839e+00 -0.88114109 0.85709257 573.50 2.02233112e+00 -4.16049832e+00 4.62596687e+00 -1.11834736 0.84140584 573.75 1.05828332e+00 -4.12965826e+00 4.26310226e+00 -1.31993075 0.90936264 574.00 5.12406208e-01 -3.90006887e+00 3.93358581e+00 -1.44016068 0.89991279 574.25 9.08416339e-03 -3.64030126e+00 3.64031259e+00 -1.56830089 0.90316775 574.50 -4.09333170e-01 -3.16995198e+00 3.19627114e+00 -1.69921485 0.86781029 574.75 -6.36874500e-01 -2.89101945e+00 2.96033825e+00 -1.78762713 0.84762290 575.00 -1.27232564e+00 -2.26160126e+00 2.59492828e+00 -2.08324454 0.75159411 575.25 -1.52781039e+00 -1.83551740e+00 2.38816430e+00 -2.26495962 0.75286021 575.50 -1.60391670e+00 -1.53634161e+00 2.22101201e+00 -2.37771013 0.69709444 575.75 -1.79617954e+00 -1.54606505e+00 2.36993209e+00 -2.43088955 0.65486461 576.00 -1.60144963e+00 -1.34517067e+00 2.09144090e+00 -2.44295004 0.36759761 576.25 -1.25247975e+00 -1.17473960e+00 1.71718335e+00 -2.38821202 0.14199040 576.50 -2.89868395e-02 -2.29385842e+00 2.29404156e+00 -1.58343237 0.31185787 576.75 -2.75055192e-01 -2.04452770e+00 2.06294665e+00 -1.70452578 0.47554532 577.00 -3.37269148e-01 -1.76897841e+00 1.80084288e+00 -1.75919287 0.66818765 577.25 -2.64138538e-01 -1.60186815e+00 1.62349953e+00 -1.73421981 0.69803588 577.50 -2.19948298e-01 -1.36188389e+00 1.37953071e+00 -1.73091670 0.69144461 577.75 -1.74621828e-01 -1.19403080e+00 1.20673209e+00 -1.71601255 0.65789107 578.00 -5.64411812e-02 -9.72650636e-01 9.74286850e-01 -1.62875954 0.62777361 578.25 -4.71593826e-02 -9.66398064e-01 9.67548048e-01 -1.61955677 0.59986689 578.50 -7.27915625e-02 -8.14604589e-01 8.17850382e-01 -1.65991778 0.65430878 578.75 4.26933136e-02 -7.14125275e-01 7.15400327e-01 -1.51108333 0.59449886 579.00 2.71223269e-01 -6.08303331e-01 6.66029281e-01 -1.15138350 0.57994732 579.25 3.62069068e-01 -6.09575204e-01 7.08996431e-01 -1.03482283 0.64642331 579.50 7.45859024e-01 -6.42351221e-01 9.84337734e-01 -0.71097383 0.82406529 579.75 8.35283726e-01 -7.56606375e-01 1.12701025e+00 -0.73601449 0.87712789 580.00 8.56588706e-01 -9.21254946e-01 1.25795663e+00 -0.82175555 0.92330139 580.25 8.60806700e-01 -1.01265370e+00 1.32908077e+00 -0.86627299 0.93562299 580.50 8.54672305e-01 -1.14766996e+00 1.43094762e+00 -0.93069446 0.95882074 580.75 9.10791235e-01 -1.14451786e+00 1.46268992e+00 -0.89863021 0.94892154 581.00 1.09548423e+00 -1.13436329e+00 1.57697995e+00 -0.80283215 0.93222740 581.25 1.29504559e+00 -1.37978935e+00 1.89234292e+00 -0.81706944 0.93198888 581.50 1.45716939e+00 -1.79416458e+00 2.31135657e+00 -0.88867766 0.95767067 581.75 1.43132962e+00 -2.19397175e+00 2.61958327e+00 -0.99274140 0.94691623 582.00 1.15305541e+00 -2.77846553e+00 3.00822331e+00 -1.17742855 0.95999685 582.25 6.41880055e-01 -3.04719979e+00 3.11407074e+00 -1.36318562 0.92727547 582.50 8.13992570e-03 -3.25615312e+00 3.25616330e+00 -1.56829647 0.95236597 582.75 -6.23446251e-01 -2.92703451e+00 2.99269382e+00 -1.78065611 0.92579985 583.00 -1.13201880e+00 -2.55874385e+00 2.79797010e+00 -1.98732212 0.93910541 583.25 -1.30853056e+00 -2.14254285e+00 2.51052626e+00 -2.11907342 0.92254925 583.50 -1.21671567e+00 -1.84264004e+00 2.20810311e+00 -2.15438601 0.94067269 583.75 -1.21410664e+00 -1.60957449e+00 2.01613119e+00 -2.21704558 0.92199801 584.00 -1.33439976e+00 -1.52478320e+00 2.02622470e+00 -2.28970598 0.91500889 584.25 -1.14715506e+00 -1.26299106e+00 1.70619787e+00 -2.30816963 0.88272324 584.50 -1.15214570e+00 -1.18404310e+00 1.65208891e+00 -2.34254173 0.89245816 584.75 -1.37497941e+00 -1.18462558e+00 1.81491215e+00 -2.43042628 0.90145099 585.00 -1.43773868e+00 -1.14234370e+00 1.83631197e+00 -2.47018866 0.91373052 585.25 -1.59826257e+00 -9.39441980e-01 1.85391328e+00 -2.61019983 0.88329617 585.50 -1.66793643e+00 -8.04165124e-01 1.85167316e+00 -2.69234155 0.90135699 585.75 -1.53284460e+00 -4.90813807e-01 1.60950637e+00 -2.83171009 0.86685362 586.00 -1.52005828e+00 -2.42989721e-01 1.53935739e+00 -2.98307826 0.85906715 586.25 -1.58414974e+00 -2.92796803e-02 1.58442031e+00 -3.12311186 0.78066742 586.50 -1.54037013e+00 1.89823526e-01 1.55202226e+00 3.01897843 0.68996558 586.75 -6.24514581e-01 7.55886915e-01 9.80501652e-01 2.26131061 0.26764162 587.00 -2.79371364e-01 1.04831762e+00 1.08490469e+00 1.83123841 0.31462475 587.25 6.08256176e-01 8.05015652e-01 1.00897263e+00 0.92373164 0.35359783 587.50 1.09737380e+00 4.79567518e-01 1.19758685e+00 0.41200230 0.49631667 587.75 1.09460801e+00 -1.14859318e-01 1.10061772e+00 -0.10454932 0.62669697 588.00 1.04421693e+00 -4.31356070e-01 1.12980399e+00 -0.39174009 0.73745634 588.25 9.32017507e-01 -8.39805889e-01 1.25456389e+00 -0.73340173 0.80296677 588.50 7.93597452e-01 -9.45197458e-01 1.23417792e+00 -0.87236507 0.84728297 588.75 6.14129392e-01 -1.02153612e+00 1.19192741e+00 -1.02950797 0.90550806 589.00 5.26491029e-01 -1.06866116e+00 1.19131418e+00 -1.11303461 0.89381573 589.25 5.12367221e-01 -1.18909343e+00 1.29478313e+00 -1.16394828 0.94407271 589.50 4.94043730e-01 -1.26958276e+00 1.36232140e+00 -1.19968810 0.95445074 589.75 3.63429036e-01 -1.44818313e+00 1.49308910e+00 -1.32491889 0.95674894 590.00 2.80703552e-01 -1.50441310e+00 1.53037683e+00 -1.38633076 0.96000643 590.25 1.07417477e-01 -1.62928707e+00 1.63282420e+00 -1.50496247 0.96980709 590.50 -4.61279953e-02 -1.65010822e+00 1.65075284e+00 -1.59874358 0.95210158 590.75 -3.99002015e-01 -1.63832672e+00 1.68621382e+00 -1.80968807 0.96700083 591.00 -5.05446618e-01 -1.62186131e+00 1.69879675e+00 -1.87290300 0.97083139 591.25 -5.84050090e-01 -1.53888825e+00 1.64599257e+00 -1.93353021 0.97074625 591.50 -6.78971640e-01 -1.45744727e+00 1.60784173e+00 -2.00676384 0.95744727 591.75 -6.63623866e-01 -1.34305498e+00 1.49806319e+00 -2.02972502 0.95415429 592.00 -6.62625878e-01 -1.33565213e+00 1.49098614e+00 -2.03132439 0.93970160 592.25 -7.64255618e-01 -1.37438537e+00 1.57258444e+00 -2.07828849 0.95546945 592.50 -7.94910830e-01 -1.37748288e+00 1.59039062e+00 -2.09418857 0.94054571 592.75 -9.04487347e-01 -1.42742491e+00 1.68986368e+00 -2.13559147 0.92437641 593.00 -1.13869677e+00 -1.35958189e+00 1.77344108e+00 -2.26800888 0.89120177 593.25 -1.30327261e+00 -1.26133587e+00 1.81369448e+00 -2.37254514 0.94033028 593.50 -1.42123987e+00 -1.23040144e+00 1.87984320e+00 -2.42804054 0.92831680 593.75 -1.67356845e+00 -1.22343329e+00 2.07307028e+00 -2.51034153 0.90491786 594.00 -2.03142248e+00 -8.04573935e-01 2.18495229e+00 -2.76448371 0.83976484 594.25 -2.43213165e+00 -2.34401699e-01 2.44340102e+00 -3.04551234 0.85106939 594.50 -2.25802038e+00 1.79039658e-01 2.26510733e+00 3.06246765 0.85110407 594.75 -1.91214360e+00 6.43782624e-01 2.01760978e+00 2.81683214 0.84078522 595.00 -1.22741337e+00 8.51711257e-01 1.49397311e+00 2.53496738 0.78799868 595.25 -7.67306100e-01 8.63156587e-01 1.15490170e+00 2.29747478 0.74406544 595.50 -4.54142882e-01 6.87163747e-01 8.23674555e-01 2.15479231 0.64292364 595.75 -2.11691187e-01 5.55045899e-01 5.94044702e-01 1.93516090 0.55242486 596.00 -1.19296098e-01 1.56040848e-01 1.96418698e-01 2.22352464 0.12003839 596.25 -1.21766975e-01 -1.20841232e-01 1.71551157e-01 -2.36001027 0.10750101 596.50 -2.64785394e-01 -4.54907621e-01 5.26357529e-01 -2.09792326 0.46128937 596.75 -4.38520605e-01 -6.45510248e-01 7.80374142e-01 -2.16752119 0.67475334 597.00 -7.21974320e-01 -8.69084573e-01 1.12984730e+00 -2.26399603 0.73178325 597.25 -8.66557826e-01 -9.43748755e-01 1.28124322e+00 -2.31358060 0.76477716 597.50 -1.41562181e+00 -8.86976917e-01 1.67054278e+00 -2.58186983 0.78689915 597.75 -1.75238460e+00 -8.92522106e-01 1.96658269e+00 -2.67051797 0.83582663 598.00 -2.05129445e+00 -1.05110201e+00 2.30491309e+00 -2.66806709 0.82309113 598.25 -2.21035104e+00 -1.15224522e+00 2.49265336e+00 -2.66105444 0.78346326 598.50 -3.85589801e+00 -1.68948486e+00 4.20978723e+00 -2.72863173 0.73572867 598.75 -4.90303269e+00 -1.37104500e+00 5.09111913e+00 -2.86892520 0.71244826 599.00 -8.98208531e+00 1.39905829e+00 9.09039167e+00 2.98707333 0.77375672 599.25 -1.01804913e+01 4.50908701e+00 1.11343733e+01 2.72464665 0.77685164 599.50 -4.99899585e+00 1.09444706e+01 1.20320986e+01 1.99925759 0.80270655 599.75 -2.02976876e+00 1.24382005e+01 1.26027296e+01 1.73255875 0.82643626 600.00 3.68983928e+00 1.30832500e+01 1.35936141e+01 1.29590830 0.83817983 600.25 5.73777384e+00 1.14756677e+01 1.28301597e+01 1.10715290 0.83927727 600.50 7.46174827e+00 9.14829425e+00 1.18054638e+01 0.88658909 0.83078991 600.75 8.57560354e+00 6.77170700e+00 1.09268931e+01 0.66839671 0.74209241 601.00 9.80715747e+00 3.19951043e+00 1.03158715e+01 0.31535518 0.75732243 601.25 9.74185845e+00 2.93405581e+00 1.01741088e+01 0.29253928 0.75672926 601.50 8.72590175e+00 1.85305390e+00 8.92049158e+00 0.20925379 0.66846101 601.75 9.16830083e+00 2.57688489e+00 9.52355374e+00 0.27399564 0.60627906 602.00 1.46847403e+01 4.11721279e+00 1.52510012e+01 0.27335506 0.63212266 602.25 1.55025897e+01 -2.58821932e+00 1.57171616e+01 -0.16542823 0.54093830 602.50 1.45150929e+01 -1.38870372e+01 2.00882484e+01 -0.76328879 0.76070784 602.75 9.78858647e+00 -1.68494855e+01 1.94864463e+01 -1.04450738 0.79126795 603.00 4.53064275e+00 -1.70439529e+01 1.76358457e+01 -1.31098351 0.84940542 603.25 3.69925775e-01 -1.57546374e+01 1.57589798e+01 -1.54732020 0.86967436 603.50 -1.98097375e+00 -1.59404979e+01 1.60631171e+01 -1.69443546 0.93426981 603.75 -3.81613190e+00 -1.38831059e+01 1.43980378e+01 -1.83904720 0.92957205 604.00 -5.54588534e+00 -1.20373632e+01 1.32534885e+01 -2.00253131 0.95826050 604.25 -6.45251648e+00 -1.04321304e+01 1.22663896e+01 -2.12472473 0.95435063 604.50 -7.16933942e+00 -9.09844455e+00 1.15836575e+01 -2.23816132 0.96965216 604.75 -7.70830273e+00 -7.99381780e+00 1.11049113e+01 -2.33801328 0.96587671 605.00 -7.74500384e+00 -7.24693773e+00 1.06067521e+01 -2.38940453 0.97016052 605.25 -8.12833866e+00 -6.23068389e+00 1.02416459e+01 -2.48759070 0.96024797 605.50 -8.57374116e+00 -5.51280254e+00 1.01931364e+01 -2.57016342 0.96715444 605.75 -9.24643992e+00 -5.06890104e+00 1.05446863e+01 -2.64013223 0.91918206 606.00 -1.07601041e+01 -4.49040416e+00 1.16594841e+01 -2.74624517 0.94732184 606.25 -1.17615897e+01 -2.76313321e+00 1.20818003e+01 -2.91084841 0.93217237 606.50 -1.26032299e+01 -1.09067117e+00 1.26503347e+01 -3.05526870 0.92431387 606.75 -1.37023642e+01 1.85034118e+00 1.38267331e+01 3.00736651 0.92320976 607.00 -1.36044971e+01 3.75754450e+00 1.41138755e+01 2.87211236 0.92338404 607.25 -1.18335315e+01 7.75895455e+00 1.41504008e+01 2.56123809 0.89531897 607.50 -1.13928439e+01 1.04315332e+01 1.54471285e+01 2.40021360 0.92688742 607.75 -8.75474447e+00 1.29087852e+01 1.55975090e+01 2.16674144 0.89178976 608.00 -6.20557007e+00 1.45031680e+01 1.57750113e+01 1.97510118 0.88089610 608.25 -1.59938485e+00 1.53332295e+01 1.54164185e+01 1.67472889 0.88924758 608.50 8.18338676e-01 1.50460302e+01 1.50682681e+01 1.51646085 0.88559865 608.75 5.61473303e+00 1.29986187e+01 1.41594250e+01 1.16305504 0.90592888 609.00 6.77346668e+00 1.20916892e+01 1.38596103e+01 1.06017450 0.93271197 609.25 8.70939684e+00 8.75947979e+00 1.23524119e+01 0.78826514 0.92581667 609.50 9.53114530e+00 7.49984247e+00 1.21280818e+01 0.66668796 0.93152985 609.75 9.69256306e+00 4.90718448e+00 1.08639881e+01 0.46866174 0.87767353 610.00 9.03043039e+00 3.41067229e+00 9.65304918e+00 0.36112394 0.83349802 610.25 7.37325445e+00 1.20842038e+00 7.47162372e+00 0.16244818 0.79963532 610.50 6.68596664e+00 1.40334058e+00 6.83165534e+00 0.20689014 0.78768537 610.75 6.90954450e+00 1.69863267e+00 7.11527639e+00 0.24105822 0.83009526 611.00 6.87442339e+00 1.29388449e+00 6.99512931e+00 0.18604067 0.79113269 611.25 6.74806456e+00 1.96965860e-01 6.75093852e+00 0.02918021 0.69959441 611.50 6.68953911e+00 -3.60051837e-01 6.69922165e+00 -0.05377123 0.64506861 611.75 7.20417575e+00 -2.08474681e+00 7.49975450e+00 -0.28168574 0.72658193 612.00 6.46170234e+00 -2.60394111e+00 6.96664241e+00 -0.38307327 0.66954673 612.25 5.51025342e+00 -3.52673548e+00 6.54222867e+00 -0.56933550 0.67694972 612.50 4.88737005e+00 -4.31215376e+00 6.51774931e+00 -0.72295271 0.67923300 612.75 4.27530075e+00 -5.15781704e+00 6.69934871e+00 -0.87868174 0.74703395 613.00 2.15003575e+00 -5.49526422e+00 5.90089676e+00 -1.19785359 0.63293206 613.25 -2.10891749e-01 -5.34970571e+00 5.35386090e+00 -1.61019711 0.69908804 613.50 -2.16958270e-01 -3.69299821e+00 3.69936571e+00 -1.62947742 0.50925263 613.75 5.75092632e-01 -1.74556103e+00 1.83785604e+00 -1.25253576 0.38141654 614.00 1.02504599e+00 -1.36233807e+00 1.70490008e+00 -0.92575029 0.38958400 614.25 1.59442824e+00 -1.76999235e+00 2.38224145e+00 -0.83753344 0.51765307 614.50 1.80760619e+00 -2.15209768e+00 2.81050966e+00 -0.87217897 0.60027229 614.75 1.86873293e+00 -2.25614237e+00 2.92956331e+00 -0.87904374 0.74925965 615.00 1.37510991e+00 -2.45464269e+00 2.81357388e+00 -1.06014985 0.71547264 615.25 1.13269081e+00 -2.83617906e+00 3.05399740e+00 -1.19083135 0.77122719 615.50 6.49937332e-01 -2.61564471e+00 2.69518382e+00 -1.32724807 0.71380279 615.75 1.79694291e-01 -2.76110234e+00 2.76694347e+00 -1.50580734 0.84240700 616.00 -3.83337339e-02 -2.11561604e+00 2.11596330e+00 -1.58891376 0.75002746 616.25 -9.81430278e-02 -1.62779609e+00 1.63075202e+00 -1.63101540 0.75191164 616.50 2.43510687e-01 -1.48405226e+00 1.50389779e+00 -1.40816061 0.68485914 616.75 4.71311702e-01 -1.49175399e+00 1.56443750e+00 -1.26477635 0.77904538 617.00 3.46991790e-01 -1.61346096e+00 1.65035134e+00 -1.35896230 0.75576468 617.25 6.97069879e-02 -1.70396728e+00 1.70539249e+00 -1.52991048 0.79142429 617.50 -5.07582703e-01 -1.71795777e+00 1.79137352e+00 -1.85808007 0.69091067 617.75 -9.98278526e-01 -1.57160289e+00 1.86185275e+00 -2.13669523 0.68580436 618.00 -1.58879807e+00 -3.92460901e-01 1.63655274e+00 -2.89942303 0.56388484 618.25 -1.32484573e+00 4.16003839e-01 1.38862356e+00 2.83734026 0.49552393 618.50 -6.86374912e-01 1.44854077e+00 1.60292885e+00 2.01329685 0.64267127 618.75 -2.16882758e-01 1.59655964e+00 1.61122339e+00 1.70581368 0.63164604 619.00 1.24070514e+00 1.53952131e+00 1.97723926e+00 0.89246623 0.75171101 619.25 1.68759645e+00 1.35472251e+00 2.16408291e+00 0.67641713 0.85048847 619.50 1.94700554e+00 6.76475139e-01 2.06117665e+00 0.33439583 0.87739807 619.75 1.93337664e+00 4.33722647e-01 1.98142892e+00 0.22068071 0.89480197 620.00 1.86211431e+00 8.82232630e-02 1.86420306e+00 0.04734260 0.89889233 620.25 1.81602516e+00 -7.38796711e-02 1.81752733e+00 -0.04065965 0.89650407 620.50 1.73511651e+00 -5.34453748e-01 1.81556330e+00 -0.29879992 0.91362240 620.75 1.62325842e+00 -6.51293824e-01 1.74904304e+00 -0.38156301 0.91231526 621.00 1.21130626e+00 -7.59896016e-01 1.42993175e+00 -0.56027737 0.85740257 621.25 9.00896568e-01 -7.27137645e-01 1.15773217e+00 -0.67907139 0.74721511 621.50 5.26265199e-01 -5.45646284e-01 7.58079763e-01 -0.80347706 0.72454476 621.75 4.21664892e-01 -3.49876097e-01 5.47918392e-01 -0.69261931 0.45995987 622.00 4.36478924e-01 -2.45401225e-02 4.37168239e-01 -0.05616380 0.47392612 622.25 5.06468221e-01 1.48212977e-01 5.27709338e-01 0.28469111 0.49560016 622.50 7.86510778e-01 4.27142260e-01 8.95013807e-01 0.49751875 0.73499519 622.75 1.03581402e+00 4.80918187e-01 1.14201269e+00 0.43467382 0.75648454 623.00 1.36341471e+00 5.13980188e-01 1.45707766e+00 0.36050550 0.85047869 623.25 1.56952424e+00 4.01135828e-01 1.61997416e+00 0.25022159 0.83601100 623.50 1.83899292e+00 7.63507333e-02 1.84057719e+00 0.04149386 0.83565014 623.75 1.89734539e+00 -3.37404813e-01 1.92711223e+00 -0.17599019 0.80675679 624.00 1.65799841e+00 -9.96572660e-01 1.93445491e+00 -0.54120570 0.80850118 624.25 1.24092474e+00 -1.21982096e+00 1.74007396e+00 -0.77682220 0.77100619 624.50 7.25824670e-01 -1.37758562e+00 1.55710102e+00 -1.08587534 0.80897589 624.75 2.96970540e-01 -1.22626416e+00 1.26171126e+00 -1.33319581 0.76483592 625.00 1.52230412e-02 -1.05672341e+00 1.05683305e+00 -1.55639143 0.80197965 625.25 -1.59165781e-01 -5.84270892e-01 6.05562730e-01 -1.83676029 0.53908498 625.50 -2.02526283e-01 -3.07374715e-01 3.68097964e-01 -2.15339610 0.49841221 625.75 -1.41303142e-01 -1.08790664e-01 1.78331114e-01 -2.48547061 0.14723985 626.00 -1.33602473e-01 2.43856534e-02 1.35809723e-01 2.96105604 0.13502968 626.25 -8.62278901e-02 1.83734502e-01 2.02962105e-01 2.00958946 0.22225563 626.50 -5.29309179e-02 3.07860162e-01 3.12377274e-01 1.74106331 0.41454045 626.75 -6.12294871e-04 4.32298380e-01 4.32298814e-01 1.57221270 0.59704026 627.00 3.77085473e-02 5.31080166e-01 5.32417202e-01 1.49991179 0.72327926 627.25 1.00382503e-01 7.19036691e-01 7.26009924e-01 1.43208592 0.73130141 627.50 1.62847121e-01 8.31691390e-01 8.47484367e-01 1.37744022 0.78055586 627.75 4.09061986e-01 1.01256194e+00 1.09206840e+00 1.18685751 0.77469345 628.00 6.52746573e-01 1.07714722e+00 1.25949363e+00 1.02597989 0.82325806 628.25 9.70318375e-01 9.57688276e-01 1.36333583e+00 0.77884740 0.89266292 628.50 1.03277494e+00 8.89671085e-01 1.36313562e+00 0.71109677 0.91091588 628.75 1.04594548e+00 6.98326664e-01 1.25764147e+00 0.58868384 0.87872366 629.00 1.15147516e+00 6.55142687e-01 1.32480450e+00 0.51728281 0.90741935 629.25 1.29215103e+00 5.15228341e-01 1.39108394e+00 0.37941705 0.90266913 629.50 1.34348376e+00 3.88029287e-01 1.39839742e+00 0.28117158 0.91813112 629.75 1.31537899e+00 2.37722996e-01 1.33668774e+00 0.17879593 0.90228106 630.00 1.29283630e+00 1.82338863e-01 1.30563132e+00 0.14011370 0.90509989 630.25 1.26149195e+00 1.04737780e-01 1.26583251e+00 0.08283692 0.90796819 630.50 1.23081282e+00 7.27696884e-02 1.23296213e+00 0.05905453 0.90487528 630.75 1.26680715e+00 -1.41854467e-02 1.26688657e+00 -0.01119733 0.92492122 631.00 1.29489412e+00 -5.98761779e-02 1.29627772e+00 -0.04620730 0.93529593 631.25 1.28436468e+00 -2.24091922e-01 1.30376755e+00 -0.17273803 0.93571783 631.50 1.20200531e+00 -3.04065612e-01 1.23986800e+00 -0.24776756 0.91665155 631.75 1.09166146e+00 -4.51626880e-01 1.18139392e+00 -0.39226576 0.95290710 632.00 1.04471777e+00 -4.68995701e-01 1.14516033e+00 -0.42195623 0.95150554 632.25 8.43451230e-01 -4.98897595e-01 9.79953462e-01 -0.53414271 0.94352218 632.50 7.55990584e-01 -4.78066159e-01 8.94465771e-01 -0.56388192 0.94439646 632.75 6.68979339e-01 -4.85328807e-01 8.26484971e-01 -0.62762047 0.94137924 633.00 6.36981144e-01 -4.28080018e-01 7.67461713e-01 -0.59171686 0.94672249 633.25 5.88379388e-01 -4.16837395e-01 7.21071230e-01 -0.61637464 0.96242107 633.50 5.50660425e-01 -4.18322471e-01 6.91534955e-01 -0.64966385 0.95687879 633.75 5.12021302e-01 -3.87259308e-01 6.41977869e-01 -0.64754279 0.96004895 634.00 4.70419843e-01 -3.55580201e-01 5.89688144e-01 -0.64725269 0.94621464 634.25 4.27091629e-01 -3.32416934e-01 5.41210012e-01 -0.66138527 0.95643234 634.50 3.97553170e-01 -3.22808500e-01 5.12107265e-01 -0.68200822 0.92872488 634.75 3.61224292e-01 -2.78815406e-01 4.56312414e-01 -0.65734678 0.94236893 635.00 3.62319212e-01 -2.64431724e-01 4.48552503e-01 -0.63046738 0.91575257 635.25 3.62614006e-01 -2.40598016e-01 4.35173899e-01 -0.58581403 0.90159805 635.50 3.58509834e-01 -2.02222987e-01 4.11610784e-01 -0.51357780 0.84412395 635.75 3.63976050e-01 -1.69583565e-01 4.01543460e-01 -0.43601349 0.86429656 636.00 3.74372611e-01 -1.57579983e-01 4.06185059e-01 -0.39840766 0.84734764 636.25 3.65754106e-01 -1.64710127e-01 4.01130268e-01 -0.42312850 0.86254225 636.50 3.97053426e-01 -1.73090158e-01 4.33141577e-01 -0.41109754 0.81278307 636.75 3.93603958e-01 -1.84236982e-01 4.34588704e-01 -0.43778470 0.82758699 637.00 3.80888270e-01 -1.92250248e-01 4.26656808e-01 -0.46743389 0.78366103 637.25 3.81280830e-01 -2.26646481e-01 4.43557999e-01 -0.53631717 0.80453085 637.50 3.46222148e-01 -3.16036680e-01 4.68773888e-01 -0.73985012 0.69105710 637.75 2.89367013e-01 -3.58202062e-01 4.60480168e-01 -0.89129811 0.65503160 638.00 1.46103722e-01 -3.12455002e-01 3.44926696e-01 -1.13340364 0.45911734 638.25 4.77562796e-02 -2.20043442e-01 2.25166113e-01 -1.35707958 0.27451128 638.50 7.63001384e-02 -5.68006348e-02 9.51210978e-02 -0.63993118 0.05001408 638.75 9.45016100e-02 3.18990938e-02 9.97401949e-02 0.32554146 0.05606595 639.00 2.26925516e-01 1.62319790e-01 2.79003412e-01 0.62092069 0.29029780 639.25 2.76774022e-01 2.31550690e-01 3.60859503e-01 0.69666633 0.44568061 639.50 3.71837714e-01 3.32715967e-01 4.98962123e-01 0.72992813 0.38549782 639.75 5.53034975e-01 3.95481479e-01 6.79892112e-01 0.62079585 0.50519178 640.00 7.40861796e-01 1.39020830e-01 7.53792406e-01 0.18549039 0.46199373 640.25 7.55376792e-01 -2.35101502e-02 7.55742566e-01 -0.03111370 0.35222244 640.50 5.62589968e-01 -7.64922950e-01 9.49533882e-01 -0.93664920 0.34302318 640.75 7.43739497e-02 -9.79579812e-01 9.82399151e-01 -1.49501737 0.39304596 641.00 -2.08390909e-01 -8.49440698e-01 8.74629219e-01 -1.81137225 0.52866595 641.25 -3.20875282e-01 -7.00392020e-01 7.70395955e-01 -2.00039609 0.57734387 641.50 -3.62968934e-01 -4.57277896e-01 5.83823193e-01 -2.24172083 0.63602639 641.75 -3.50890357e-01 -3.65036533e-01 5.06335574e-01 -2.33643782 0.61356135 642.00 -2.23928160e-01 -2.56776651e-01 3.40702318e-01 -2.28796654 0.49612924 642.25 -2.19668460e-01 -2.19032294e-01 3.10208604e-01 -2.35764460 0.48866330 642.50 -1.65077329e-01 -1.70453400e-01 2.37286506e-01 -2.34017327 0.50046895 642.75 -1.10075138e-01 -1.61974451e-01 1.95837327e-01 -2.16768801 0.42150663 643.00 -1.29227202e-01 -1.21861970e-01 1.77623224e-01 -2.38551922 0.43750748 643.25 -1.34704063e-01 -9.37652479e-02 1.64125276e-01 -2.53350019 0.32821573 643.50 -8.37759052e-02 -7.98921447e-02 1.15763367e-01 -2.37991953 0.25508083 643.75 -6.47667712e-02 -5.26036917e-02 8.34378993e-02 -2.45945571 0.14138449 644.00 -6.35018500e-02 2.22196095e-02 6.72770095e-02 2.80500254 0.10943705 644.25 -2.09480838e-02 -1.95423347e-02 2.86482995e-02 -2.39089862 0.01732516 644.50 8.39125365e-03 -8.78802210e-02 8.82799319e-02 -1.47559982 0.19643715 644.75 1.41610875e-02 -8.99075236e-02 9.10159283e-02 -1.41457253 0.16963039 645.00 1.24768026e-02 -1.12118499e-01 1.12810586e-01 -1.45997002 0.24775339 645.25 -3.59435795e-02 -1.06934700e-01 1.12813877e-01 -1.89505856 0.23271643 645.50 -7.28172298e-02 -9.78576037e-02 1.21977291e-01 -2.21051985 0.37825118 645.75 -1.00240053e-01 -9.76891534e-02 1.39968707e-01 -2.36908172 0.37867952 646.00 -1.38690870e-01 -7.98780220e-02 1.60048917e-01 -2.61905005 0.41878916 646.25 -2.05578874e-01 -5.57983540e-02 2.13016736e-01 -2.87655716 0.58131346 646.50 -2.61797402e-01 -3.68254782e-03 2.61823301e-01 -3.12752718 0.69782298 646.75 -2.84107421e-01 9.05263863e-02 2.98181242e-01 2.83312899 0.72562926 647.00 -2.69952438e-01 1.55430879e-01 3.11501327e-01 2.61917888 0.78317291 647.25 -2.13904605e-01 2.78383329e-01 3.51073294e-01 2.22595819 0.87316386 647.50 -1.68119106e-01 3.04389193e-01 3.47730952e-01 2.07541613 0.90788392 647.75 -1.00145245e-01 3.52884691e-01 3.66819677e-01 1.84731628 0.89962864 648.00 -7.53672883e-02 3.89725021e-01 3.96945614e-01 1.76182407 0.94225983 648.25 1.43646163e-02 4.10148836e-01 4.10400304e-01 1.53578770 0.93148240 648.50 5.37332357e-02 4.17790913e-01 4.21232130e-01 1.44288576 0.95420929 648.75 1.15014673e-01 4.31159797e-01 4.46236648e-01 1.31011008 0.96198722 649.00 1.51476188e-01 4.34946266e-01 4.60568442e-01 1.23566876 0.96999810 649.25 2.03957395e-01 4.19514095e-01 4.66466178e-01 1.11826951 0.96055048 649.50 2.36581766e-01 4.14048773e-01 4.76872434e-01 1.05168213 0.96468402 649.75 3.04283252e-01 4.13485339e-01 5.13379414e-01 0.93638141 0.96875025 650.00 3.35941526e-01 4.05647778e-01 5.26694246e-01 0.87911856 0.97381415 650.25 4.37045196e-01 4.06851397e-01 5.97106827e-01 0.74963439 0.97622421 650.50 4.69711100e-01 3.95778186e-01 6.14222183e-01 0.70018178 0.97601705 650.75 5.31841202e-01 3.48085784e-01 6.35624714e-01 0.57952653 0.97227330 651.00 5.58056715e-01 3.13171894e-01 6.39924943e-01 0.51138838 0.96931731 651.25 5.98523126e-01 2.64824074e-01 6.54493486e-01 0.41656814 0.96192270 651.50 6.18260289e-01 2.38520737e-01 6.62674827e-01 0.36819963 0.96169826 651.75 6.68818645e-01 1.46935652e-01 6.84768914e-01 0.21625871 0.94893462 652.00 6.71103521e-01 9.54880314e-02 6.77862745e-01 0.14133641 0.93751996 652.25 5.77925467e-01 -3.89447686e-02 5.79236170e-01 -0.06728546 0.88698570 652.50 4.70652700e-01 -4.30777988e-02 4.72619996e-01 -0.09127348 0.80682024 652.75 3.09259407e-01 9.52736899e-02 3.23602313e-01 0.29884435 0.75536522 653.00 3.30157768e-01 1.86976370e-01 3.79426296e-01 0.51528983 0.79338588 653.25 4.52798518e-01 3.54672572e-01 5.75168786e-01 0.66446857 0.84938226 653.50 5.44425057e-01 3.69494739e-01 6.57970368e-01 0.59627894 0.85452102 653.75 7.15092119e-01 4.19228090e-01 8.28920340e-01 0.53025340 0.89690260 654.00 8.60586760e-01 4.04570274e-01 9.50939892e-01 0.43945082 0.90685606 654.25 1.10161028e+00 4.05278857e-01 1.17379562e+00 0.35252868 0.93435192 654.50 1.16907935e+00 2.68875561e-01 1.19960018e+00 0.22605808 0.89133617 654.75 1.31748366e+00 -2.82521661e-03 1.31748669e+00 -0.00214440 0.94363773 655.00 1.30251139e+00 -1.04395630e-01 1.30668832e+00 -0.07997853 0.93740435 655.25 1.26915645e+00 -1.42624154e-01 1.27714516e+00 -0.11190762 0.95250640 655.50 1.26649975e+00 -1.91151582e-01 1.28084368e+00 -0.14979841 0.94490459 655.75 1.29695782e+00 -2.40231098e-01 1.31901879e+00 -0.18315087 0.95913386 656.00 1.37902616e+00 -2.02432869e-01 1.39380495e+00 -0.14575310 0.94721227 656.25 1.49154591e+00 -2.24799335e-01 1.50839118e+00 -0.14958979 0.95712495 656.50 1.60179581e+00 -3.44294014e-01 1.63837974e+00 -0.21172121 0.95011304 656.75 1.68694192e+00 -4.69396436e-01 1.75102999e+00 -0.27138786 0.97125870 657.00 1.67824400e+00 -6.68019190e-01 1.80630910e+00 -0.37882121 0.95167762 657.25 1.66241491e+00 -8.77954076e-01 1.88000710e+00 -0.48588949 0.96615655 657.50 1.52446789e+00 -1.10292785e+00 1.88160894e+00 -0.62631367 0.95683595 657.75 1.36209212e+00 -1.24003530e+00 1.84200502e+00 -0.73852597 0.96179891 658.00 1.09434663e+00 -1.15603790e+00 1.59185997e+00 -0.81280496 0.94394606 658.25 9.73493355e-01 -1.09189087e+00 1.46284482e+00 -0.84266019 0.95531367 658.50 9.53389275e-01 -9.95417483e-01 1.37833489e+00 -0.80696094 0.95250529 658.75 9.72775963e-01 -9.12567388e-01 1.33381870e+00 -0.75347394 0.95206694 659.00 1.03689629e+00 -8.53657923e-01 1.34308814e+00 -0.68877687 0.93785728 659.25 1.09644390e+00 -8.33607648e-01 1.37734924e+00 -0.65004981 0.94302245 659.50 1.23711272e+00 -8.22576327e-01 1.48562434e+00 -0.58678979 0.92769099 659.75 1.25730459e+00 -8.45625063e-01 1.51522163e+00 -0.59207824 0.93448035 660.00 1.23953938e+00 -9.26264047e-01 1.54739231e+00 -0.64174823 0.85911566 660.25 1.10139511e+00 -1.05997034e+00 1.52859684e+00 -0.76623449 0.86172742 660.50 1.02382418e+00 -1.05865869e+00 1.47274375e+00 -0.80212400 0.92385191 660.75 1.05342556e+00 -1.04455082e+00 1.48350660e+00 -0.78116805 0.92782237 661.00 1.12206479e+00 -1.23639234e+00 1.66963930e+00 -0.83383581 0.91031717 661.25 9.63307505e-01 -1.39222175e+00 1.69299816e+00 -0.96551310 0.91657932 661.50 8.15676819e-01 -1.42453775e+00 1.64153480e+00 -1.05077472 0.95047060 661.75 7.13519942e-01 -1.40568804e+00 1.57641034e+00 -1.10109135 0.94917365 662.00 5.11177435e-01 -1.30704751e+00 1.40345130e+00 -1.19799170 0.95579620 662.25 4.80542006e-01 -1.20805943e+00 1.30012623e+00 -1.19220512 0.94738451 662.50 5.31485449e-01 -1.13391856e+00 1.25229712e+00 -1.13248788 0.94823826 662.75 5.34629570e-01 -1.11677001e+00 1.23814540e+00 -1.12431031 0.93970132 663.00 4.83251313e-01 -1.14465729e+00 1.24248627e+00 -1.17131674 0.93325081 663.25 4.76633410e-01 -1.17518464e+00 1.26816338e+00 -1.18548740 0.93014412 663.50 4.89184128e-01 -1.26759026e+00 1.35870754e+00 -1.20248945 0.93557409 663.75 4.38328855e-01 -1.27147516e+00 1.34490939e+00 -1.23881478 0.92381670 664.00 2.89841648e-01 -1.46554085e+00 1.49392709e+00 -1.37554484 0.93433402 664.25 1.79367720e-01 -1.57257298e+00 1.58276927e+00 -1.45722710 0.92370463 664.50 -5.33405449e-02 -1.55689222e+00 1.55780570e+00 -1.60504384 0.90749067 664.75 -2.77327164e-01 -1.50927556e+00 1.53454328e+00 -1.75251777 0.84473499 665.00 -6.43047986e-01 -1.37644003e+00 1.51924253e+00 -2.00784657 0.83855096 665.25 -9.57965521e-01 -1.15732369e+00 1.50236349e+00 -2.26222576 0.82998027 665.50 -1.05273528e+00 -6.96240960e-01 1.26214225e+00 -2.55727029 0.81224352 665.75 -9.28455351e-01 -3.40470575e-01 9.88913318e-01 -2.79011278 0.66150390 666.00 -7.63534352e-01 -2.51590430e-02 7.63948744e-01 -3.10865380 0.63363439 666.25 -5.96219207e-01 1.15505250e-01 6.07304541e-01 2.95023363 0.50932316 666.50 -3.81050454e-01 2.65962136e-01 4.64688397e-01 2.53222979 0.46833511 666.75 -1.19559895e-01 2.72673791e-01 2.97734050e-01 1.98402254 0.24271736 667.00 4.05074476e-02 2.17213859e-01 2.20958625e-01 1.38642766 0.18257516 667.25 1.82575117e-01 1.49337074e-01 2.35871225e-01 0.68558984 0.18189734 667.50 2.34065758e-01 1.01287500e-01 2.55041049e-01 0.40840057 0.26966440 667.75 1.84931320e-01 -8.32645967e-02 2.02811702e-01 -0.42305852 0.16309152 668.00 1.66898832e-01 -1.82972931e-01 2.47657654e-01 -0.83130871 0.31673087 668.25 8.92028106e-02 -1.55604948e-01 1.79360088e-01 -1.05026721 0.16018789 668.50 1.00854385e-01 -1.35259016e-01 1.68720504e-01 -0.93009216 0.20458104 668.75 1.00261129e-01 -1.53867266e-01 1.83650291e-01 -0.99329159 0.18198183 669.00 9.69554189e-02 -1.80152300e-01 2.04585445e-01 -1.07706870 0.23076933 669.25 5.48922822e-02 -2.92125037e-01 2.97237615e-01 -1.38505542 0.35435621 669.50 1.06537051e-03 -3.04188639e-01 3.04190504e-01 -1.56729401 0.39133862 669.75 -1.08972734e-01 -2.75228411e-01 2.96016444e-01 -1.94779403 0.31578048 670.00 -1.06638281e-01 -2.32340757e-01 2.55644187e-01 -2.00108762 0.24697787 670.25 -1.31639636e-02 -1.55671573e-01 1.56227170e-01 -1.65515804 0.08799376 670.50 -6.49286453e-02 -1.05829863e-01 1.24159933e-01 -2.12109711 0.05176337 670.75 -2.55655357e-01 -9.95962723e-02 2.74370332e-01 -2.77010778 0.18113871 671.00 -3.31517952e-01 -7.59469475e-02 3.40106001e-01 -2.91639015 0.25760575 671.25 -4.48039889e-01 3.66122126e-02 4.49533309e-01 3.06005740 0.33246120 671.50 -3.85442635e-01 1.45156759e-01 4.11869530e-01 2.78142211 0.27914486 671.75 -2.26859550e-01 3.36717555e-01 4.06009812e-01 2.16367879 0.34151128 672.00 -1.71820500e-01 4.13609641e-01 4.47878577e-01 1.96452222 0.33465145 672.25 2.91054274e-01 6.16586953e-01 6.81829936e-01 1.12976510 0.40493737 672.50 3.47047397e-01 5.29183360e-01 6.32832462e-01 0.99034275 0.38989745 672.75 3.23687668e-01 2.90364359e-01 4.34839244e-01 0.73118345 0.33348971 673.00 4.05139213e-01 1.57795976e-01 4.34784259e-01 0.37140969 0.33851903 673.25 4.63124317e-01 1.54970307e-04 4.63124343e-01 0.00033462 0.45882066 673.50 4.14005691e-01 -7.41963626e-02 4.20601727e-01 -0.17733325 0.45413236 673.75 3.14079105e-01 -7.07577863e-02 3.21950848e-01 -0.22158713 0.42828966 674.00 1.84899225e-01 -1.14493117e-01 2.17477349e-01 -0.55443140 0.25047743 674.25 4.94386681e-02 -1.54854755e-01 1.62555151e-01 -1.26176632 0.19492989 674.50 -6.79802107e-04 -1.24612063e-01 1.24613917e-01 -1.57625162 0.10518211 674.75 -6.18171105e-02 2.38890682e-02 6.62724885e-02 2.77282378 0.04419491 675.00 -8.35078636e-02 4.89159494e-02 9.67798191e-02 2.61170613 0.07622372 675.25 -1.25451333e-01 9.98404120e-02 1.60331360e-01 2.46938748 0.25889802 675.50 -9.25072148e-02 1.63979649e-01 1.88273498e-01 2.08442951 0.25480438 675.75 -1.06740962e-01 2.53577254e-01 2.75127346e-01 1.96922361 0.51025259 676.00 -1.32192488e-01 2.85634533e-01 3.14741069e-01 2.00424599 0.48087065 676.25 -1.01015327e-01 3.26194242e-01 3.41477349e-01 1.87110861 0.58083401 676.50 -1.09666508e-01 3.87129904e-01 4.02363399e-01 1.84684481 0.64209326 676.75 -6.42669062e-02 4.32534596e-01 4.37282988e-01 1.71829930 0.71190266 677.00 -3.04570913e-02 3.91851325e-01 3.93033199e-01 1.64836651 0.56582105 677.25 -4.16853777e-02 2.85557587e-01 2.88584141e-01 1.71575134 0.38498879 677.50 -1.54903273e-01 3.26972586e-01 3.61809475e-01 2.01322431 0.32109384 677.75 -3.43776571e-01 3.78968096e-01 5.11663121e-01 2.30754141 0.49577434 678.00 -3.65496440e-01 4.09390033e-01 5.48805838e-01 2.29960977 0.42599287 678.25 -4.21072188e-01 5.12618670e-01 6.63385023e-01 2.25845892 0.49235001 678.50 -5.10330385e-01 5.63736998e-01 7.60418638e-01 2.30651170 0.50396069 678.75 -6.11318606e-01 5.66739018e-01 8.33608753e-01 2.39401804 0.52151563 679.00 -8.03536064e-01 5.24758424e-01 9.59709128e-01 2.56306828 0.45731202 679.25 -1.01365566e+00 6.99041500e-01 1.23132320e+00 2.53786429 0.54260877 679.50 -1.03300122e+00 7.69009758e-01 1.28781502e+00 2.50165800 0.40756663 679.75 -1.01068399e+00 8.01877773e-01 1.29015119e+00 2.47088841 0.27270465 680.00 -1.09560451e+00 8.40566692e-01 1.38090608e+00 2.48716325 0.12773535 680.25 -6.87291578e-01 1.38018918e+00 1.54184691e+00 2.03281790 0.10929263 680.50 7.87902159e-01 1.66235629e+00 1.83962448e+00 1.12819110 0.14251619 680.75 1.64072164e+00 1.81653074e+00 2.44780543e+00 0.83620666 0.25031562 681.00 2.31826362e+00 2.14034523e+00 3.15522169e+00 0.74551486 0.26207650 681.25 2.35399288e+00 2.23560507e+00 3.24641533e+00 0.75960907 0.29481363 681.50 2.15534359e+00 1.57051908e+00 2.66684011e+00 0.62970498 0.34683205 681.75 2.61674310e+00 1.35282526e+00 2.94575638e+00 0.47714561 0.39164671 682.00 2.48722364e+00 1.32088419e+00 2.81620604e+00 0.48819178 0.28534162 682.25 2.86890880e+00 6.41541675e-01 2.93976418e+00 0.21999932 0.26539307 682.50 4.35000955e+00 -4.06293392e-01 4.36894236e+00 -0.09313039 0.30163928 682.75 5.26881983e+00 -1.54290851e+00 5.49008462e+00 -0.28487289 0.35202031 683.00 7.08988448e+00 -2.85786450e+00 7.64420378e+00 -0.38316769 0.43456901 683.25 7.24612843e+00 -4.48972702e+00 8.52431967e+00 -0.55470932 0.43718212 683.50 4.58957355e+00 -7.21277441e+00 8.54916956e+00 -1.00410400 0.49009915 683.75 2.15902330e+00 -7.66879996e+00 7.96692377e+00 -1.29636627 0.46715981 684.00 -1.14560819e+00 -7.08903047e+00 7.18100070e+00 -1.73101413 0.59893149 684.25 -1.67552190e+00 -5.99294649e+00 6.22276316e+00 -1.84341768 0.60616407 684.50 -3.19484328e+00 -4.05870183e+00 5.16527678e+00 -2.23765814 0.65122056 684.75 -2.91094733e+00 -3.32316821e+00 4.41781182e+00 -2.29016721 0.64048549 685.00 -2.35815259e+00 -2.46406235e+00 3.41064319e+00 -2.33423513 0.64692683 685.25 -1.95069013e+00 -2.75913822e+00 3.37905841e+00 -2.18619987 0.72223596 685.50 -1.66503925e+00 -2.95598188e+00 3.39266630e+00 -2.08377651 0.81552078 685.75 -2.10908020e+00 -2.79385446e+00 3.50054882e+00 -2.21742594 0.76147895 686.00 -3.18545188e+00 -3.18071974e+00 4.50156436e+00 -2.35693782 0.81756509 686.25 -3.34259812e+00 -2.72224843e+00 4.31086983e+00 -2.45812612 0.76515902 686.50 -3.82899054e+00 -1.55508286e+00 4.13272927e+00 -2.75580964 0.75950220 686.75 -3.91511439e+00 -6.73179749e-01 3.97256739e+00 -2.97131388 0.69574482 687.00 -3.60222230e+00 7.44185445e-02 3.60299092e+00 3.12093653 0.69271604 687.25 -3.25824999e+00 9.91811019e-01 3.40585997e+00 2.84610414 0.74518130 687.50 -2.98530221e+00 1.50821046e+00 3.34465665e+00 2.67378415 0.78844399 687.75 -1.91542867e+00 1.88461076e+00 2.68712201e+00 2.36430420 0.72627460 688.00 -1.18549921e+00 2.06778083e+00 2.38351126e+00 2.09136680 0.72810803 688.25 -2.89450874e-01 1.68380531e+00 1.70850289e+00 1.74103527 0.60129237 688.50 2.53246445e-01 1.25737792e+00 1.28262738e+00 1.37204693 0.59168676 688.75 3.93762254e-01 7.55957149e-01 8.52361381e-01 1.09058532 0.47937020 689.00 5.07642815e-01 5.02416974e-01 7.14229685e-01 0.78022442 0.44754381 689.25 4.10081537e-01 5.88217979e-02 4.14278736e-01 0.14246750 0.24382911 689.50 3.86913688e-01 -1.44423545e-01 4.12989542e-01 -0.35725372 0.38902019 689.75 2.46074447e-01 -2.29044990e-01 3.36175908e-01 -0.74957102 0.37147871 690.00 1.71129927e-01 -2.84974835e-01 3.32409549e-01 -1.03000271 0.41506083 690.25 5.80867766e-02 -4.39674472e-01 4.43494887e-01 -1.43944386 0.66472785 690.50 -3.27186112e-02 -5.12036299e-01 5.13080577e-01 -1.63460858 0.78630398 690.75 -1.46532813e-01 -5.03718504e-01 5.24599082e-01 -1.85388574 0.82230294 691.00 -2.02653479e-01 -4.98550351e-01 5.38164366e-01 -1.95688110 0.86777342 691.25 -2.41045683e-01 -5.07514731e-01 5.61848933e-01 -2.01420638 0.87841611 691.50 -2.79953063e-01 -4.77215636e-01 5.53270712e-01 -2.10133326 0.88481733 691.75 -2.99768042e-01 -3.95465643e-01 4.96239814e-01 -2.21940597 0.84287784 692.00 -3.14185941e-01 -3.57773592e-01 4.76145722e-01 -2.29141876 0.80203788 692.25 -3.49112121e-01 -3.68956376e-01 5.07944958e-01 -2.32856592 0.84531225 692.50 -3.66515989e-01 -3.86984983e-01 5.33002202e-01 -2.32903598 0.87251562 692.75 -3.28065785e-01 -3.43301447e-01 4.74850548e-01 -2.33350490 0.81549840 693.00 -3.67705462e-01 -3.08229286e-01 4.79804751e-01 -2.44395945 0.85857619 693.25 -3.95206284e-01 -3.14352882e-01 5.04980932e-01 -2.46965389 0.88485034 693.50 -4.26869902e-01 -3.04271215e-01 5.24212634e-01 -2.52233021 0.87454436 693.75 -4.61501305e-01 -2.08283315e-01 5.06325384e-01 -2.71764417 0.84366303 694.00 -4.55749854e-01 -1.48365636e-01 4.79291447e-01 -2.82687078 0.84221280 694.25 -4.34589115e-01 -7.65891699e-02 4.41286302e-01 -2.96715037 0.87299875 694.50 -3.95526672e-01 -4.14828609e-02 3.97696085e-01 -3.03709463 0.86096323 694.75 -3.36986065e-01 -1.97116342e-02 3.37562078e-01 -3.08316532 0.89133480 695.00 -2.97903744e-01 -1.85493732e-02 2.98480686e-01 -3.07940661 0.87884453 695.25 -2.46889063e-01 -1.04842403e-02 2.47111572e-01 -3.09915276 0.88713010 695.50 -2.50382325e-01 -8.10623055e-03 2.50513511e-01 -3.10922855 0.85357371 695.75 -2.46336433e-01 -1.56056173e-02 2.46830252e-01 -3.07832637 0.80124551 696.00 -2.35738619e-01 -3.45919237e-03 2.35763997e-01 -3.12691986 0.79105160 696.25 -2.43599618e-01 3.44532407e-02 2.46023982e-01 3.00109067 0.80489410 696.50 -2.22691119e-01 6.64432600e-02 2.32392000e-01 2.85163643 0.69355375 696.75 -1.91940084e-01 1.23744703e-01 2.28371950e-01 2.56894887 0.70756989 697.00 -1.40042511e-01 1.39381864e-01 1.97583423e-01 2.35855880 0.57146074 697.25 -7.19432216e-02 1.56926077e-01 1.72631460e-01 2.00065744 0.50901810 697.50 -1.71070700e-02 1.62479265e-01 1.63377365e-01 1.67569755 0.40461082 697.75 2.76614693e-02 1.05661212e-01 1.09222015e-01 1.31474862 0.25712500 698.00 4.28871704e-02 5.02490382e-02 6.60626614e-02 0.86427826 0.10683989 698.25 8.04452496e-02 1.45334056e-02 8.17475263e-02 0.17873416 0.15484451 698.50 9.15370671e-02 -3.93454721e-02 9.96348375e-02 -0.40595545 0.21206128 698.75 5.77837822e-02 -9.65994674e-02 1.12562972e-01 -1.03171680 0.34933234 699.00 1.94988366e-02 -1.26939895e-01 1.28428741e-01 -1.41838078 0.40527043 699.25 -1.08160544e-02 -1.40619360e-01 1.41034717e-01 -1.64756242 0.55530477 699.50 -4.55460293e-02 -1.27709054e-01 1.35587770e-01 -1.91337334 0.48809090 699.75 -6.43860723e-02 -1.09755533e-01 1.27247174e-01 -2.10132818 0.45074784 700.00 -8.19761047e-02 -6.56256796e-02 1.05008626e-01 -2.46651860 0.27624246 700.25 -1.09087952e-01 -3.32493241e-02 1.14042531e-01 -2.84574376 0.32976679 700.50 -1.28451007e-01 -2.55497397e-02 1.30967364e-01 -2.94524876 0.43687067 700.75 -1.37365492e-01 -1.52441529e-02 1.38208764e-01 -3.03106976 0.47170731 701.00 -1.10840256e-01 3.31915608e-02 1.15703250e-01 2.85063683 0.38440321 701.25 -8.98553916e-02 7.07482875e-02 1.14364818e-01 2.47460843 0.36165984 701.50 -1.01814452e-01 1.27094142e-01 1.62846871e-01 2.24620445 0.63893237 701.75 -9.69657493e-02 1.37170654e-01 1.67982573e-01 2.18613726 0.75098033 702.00 -5.58639192e-02 1.67846644e-01 1.76899048e-01 1.89209124 0.74378116 702.25 -3.75239929e-02 1.94519294e-01 1.98105542e-01 1.76136179 0.73807049 702.50 -1.94664375e-02 2.74665878e-01 2.75354838e-01 1.64155117 0.81733641 702.75 1.85391959e-02 2.94291140e-01 2.94874510e-01 1.50788336 0.82885153 703.00 6.30630428e-02 3.24590523e-01 3.30659878e-01 1.37890203 0.84159640 703.25 1.06351059e-01 3.58234485e-01 3.73687696e-01 1.28220846 0.87669205 703.50 1.79588321e-01 4.02332282e-01 4.40594178e-01 1.15096674 0.90401986 703.75 2.23094589e-01 4.11593692e-01 4.68167238e-01 1.07409560 0.89414006 704.00 3.20476065e-01 3.48287177e-01 4.73295749e-01 0.82696010 0.90200587 704.25 3.50188371e-01 3.37790109e-01 4.86553237e-01 0.76737882 0.89526812 704.50 4.15640962e-01 3.10525296e-01 5.18828843e-01 0.64164242 0.91680928 704.75 4.41686040e-01 2.91702804e-01 5.29317564e-01 0.58367262 0.92053055 705.00 4.44233267e-01 2.59366066e-01 5.14406407e-01 0.52846065 0.91725861 705.25 4.51774735e-01 2.55684283e-01 5.19109684e-01 0.51501034 0.88973109 705.50 4.97372431e-01 3.00137080e-01 5.80914453e-01 0.54294899 0.87697218 705.75 5.21296864e-01 3.23548691e-01 6.13542317e-01 0.55547313 0.87612248 706.00 5.73028873e-01 2.73303434e-01 6.34867589e-01 0.44503434 0.84324884 706.25 6.76766574e-01 2.82856691e-01 7.33499083e-01 0.39588676 0.84214640 706.50 7.63771795e-01 3.42988228e-01 8.37250428e-01 0.42208161 0.88069955 706.75 8.20943245e-01 3.44300660e-01 8.90219499e-01 0.39711481 0.86572701 707.00 9.23122960e-01 3.52602935e-01 9.88172469e-01 0.36486509 0.87645969 707.25 1.03523997e+00 3.03697051e-01 1.07886686e+00 0.28535313 0.83715254 707.50 1.20316435e+00 1.76829683e-01 1.21608931e+00 0.14592582 0.87513112 707.75 1.27130127e+00 2.16800926e-02 1.27148612e+00 0.01705181 0.86977232 708.00 1.41913276e+00 -1.53295943e-01 1.42738833e+00 -0.10760363 0.92164855 708.25 1.44565378e+00 -3.57995489e-01 1.48932052e+00 -0.24275221 0.90170495 708.50 1.36984885e+00 -5.82763765e-01 1.48865694e+00 -0.40222799 0.86352379 708.75 1.19927298e+00 -6.94901310e-01 1.38605322e+00 -0.52516127 0.86013570 709.00 1.12888507e+00 -8.63669170e-01 1.42137467e+00 -0.65307248 0.86682235 709.25 9.89753331e-01 -8.97583533e-01 1.33613916e+00 -0.73660103 0.89802457 709.50 9.88161075e-01 -9.23612911e-01 1.35259865e+00 -0.75164749 0.93174096 709.75 9.61657823e-01 -9.06258401e-01 1.32139701e+00 -0.75574845 0.92004088 710.00 1.00851062e+00 -9.47295673e-01 1.38364113e+00 -0.75410929 0.93638324 710.25 1.05415084e+00 -1.01960220e+00 1.46656832e+00 -0.76873974 0.93243329 710.50 1.10082563e+00 -1.15661613e+00 1.59673979e+00 -0.81010717 0.94408619 710.75 1.03094773e+00 -1.44891920e+00 1.77826322e+00 -0.95237475 0.93439814 711.00 9.25266454e-01 -1.61793721e+00 1.86382371e+00 -1.05130973 0.94310807 711.25 7.25472558e-01 -1.91077681e+00 2.04386360e+00 -1.20793408 0.92854741 711.50 5.28407565e-01 -1.99721205e+00 2.06593091e+00 -1.31215000 0.94863676 711.75 1.53371349e-01 -2.02887819e+00 2.03466692e+00 -1.49534567 0.94513081 712.00 -4.70974264e-02 -1.97937724e+00 1.97993748e+00 -1.59458590 0.95057052 712.25 -2.74064025e-01 -1.84791337e+00 1.86812604e+00 -1.71803305 0.97464525 712.50 -3.58210472e-01 -1.82014375e+00 1.85505741e+00 -1.76511635 0.97772453 712.75 -5.64309475e-01 -1.72809518e+00 1.81789938e+00 -1.88642950 0.95720676 713.00 -7.08471639e-01 -1.67807761e+00 1.82150392e+00 -1.97028652 0.96423741 713.25 -8.72897278e-01 -1.46102064e+00 1.70191979e+00 -2.10934401 0.97379119 713.50 -9.09541174e-01 -1.36518938e+00 1.64042897e+00 -2.15850217 0.97264451 713.75 -9.70643851e-01 -1.18102878e+00 1.52871792e+00 -2.25872692 0.97001451 714.00 -9.90452673e-01 -1.07752741e+00 1.46357843e+00 -2.31411317 0.96976974 714.25 -1.01073560e+00 -9.35955169e-01 1.37753349e+00 -2.39458974 0.97337924 714.50 -1.02980840e+00 -8.35110703e-01 1.32586395e+00 -2.46021773 0.97643349 714.75 -1.02979873e+00 -7.63255258e-01 1.28181278e+00 -2.50376715 0.97879897 715.00 -1.05937505e+00 -6.59619712e-01 1.24794778e+00 -2.58468512 0.96825501 715.25 -1.07235477e+00 -4.81161711e-01 1.17535584e+00 -2.71982334 0.96971345 715.50 -1.07340564e+00 -4.03947635e-01 1.14689728e+00 -2.78166227 0.96355888 715.75 -1.00877839e+00 -1.97061925e-01 1.02784592e+00 -2.94867502 0.95142677 716.00 -9.49880706e-01 -9.20978815e-02 9.54335044e-01 -3.04493746 0.94399582 716.25 -8.22429644e-01 1.48926987e-02 8.22564473e-01 3.12348646 0.93456881 716.50 -7.20931788e-01 2.07577392e-02 7.21230564e-01 3.11280768 0.88901310 716.75 -6.90988053e-01 3.02063184e-02 6.91647967e-01 3.09790579 0.87077648 717.00 -6.21701342e-01 9.47565152e-02 6.28881034e-01 2.99034184 0.84598449 717.25 -4.75443023e-01 1.34358287e-01 4.94062969e-01 2.86617833 0.80221240 717.50 -3.26190123e-01 9.90338796e-02 3.40892514e-01 2.84682921 0.67801798 717.75 -2.25832932e-01 6.22056955e-02 2.34243595e-01 2.87280807 0.73492613 718.00 -2.08543088e-01 1.19546387e-02 2.08885454e-01 3.08433077 0.68747978 718.25 -1.80152418e-01 -7.95644555e-02 1.96940083e-01 -2.72570360 0.65774956 718.50 -2.05037013e-01 -1.07417450e-01 2.31470700e-01 -2.65901388 0.73432961 718.75 -2.23901857e-01 -1.20925663e-01 2.54470150e-01 -2.64639487 0.78568896 719.00 -1.76138467e-01 -1.21451771e-01 2.13951611e-01 -2.53793195 0.63720976 719.25 -1.63348839e-01 -1.46996902e-01 2.19751979e-01 -2.40883523 0.66791137 719.50 -1.64368813e-01 -1.75749648e-01 2.40634672e-01 -2.32274559 0.72165412 719.75 -1.68464209e-01 -1.93876945e-01 2.56843259e-01 -2.28617431 0.77392074 720.00 -1.74893367e-01 -2.20291183e-01 2.81275479e-01 -2.24181836 0.83175611 720.25 -1.74383635e-01 -2.14638419e-01 2.76548917e-01 -2.25308459 0.76376916 720.50 -1.39196631e-01 -2.00160679e-01 2.43803199e-01 -2.17844485 0.67946083 720.75 -1.35857058e-01 -1.76785127e-01 2.22957667e-01 -2.22602446 0.70657526 721.00 -9.84578456e-02 -1.96375850e-01 2.19675720e-01 -2.03554294 0.78510736 721.25 -8.06586466e-02 -2.18209889e-01 2.32640007e-01 -1.92485772 0.83818331 721.50 -7.33049366e-02 -2.27573767e-01 2.39088755e-01 -1.88241668 0.79043039 721.75 -7.71869325e-02 -2.29247541e-01 2.41893071e-01 -1.89557102 0.80779598 722.00 -2.76239660e-02 -2.47353905e-01 2.48891619e-01 -1.68201340 0.66606071 722.25 2.79724635e-02 -2.22352794e-01 2.24105385e-01 -1.44565158 0.53603317 722.50 6.94379052e-02 -2.45327930e-01 2.54965519e-01 -1.29496978 0.44875476 722.75 1.04744819e-01 -2.36405421e-01 2.58571074e-01 -1.15371795 0.32904032 723.00 1.23924966e-01 -2.41894083e-01 2.71790627e-01 -1.09734860 0.15998060 723.25 -5.93755765e-03 -1.93692175e-01 1.93783161e-01 -1.60144134 0.05246797 723.50 -6.02849218e-01 2.57134475e-02 6.03397349e-01 3.09896529 0.28394978 723.75 -8.07374372e-01 1.46606788e-01 8.20577192e-01 2.96196523 0.49773638 724.00 -7.94622394e-01 1.52175791e-01 8.09062557e-01 2.95237657 0.74828793 724.25 -8.04442392e-01 9.37167024e-02 8.09882944e-01 3.02561648 0.80302497 724.50 -7.31272701e-01 1.21376237e-02 7.31373424e-01 3.12499623 0.79473460 724.75 -7.22927805e-01 1.56243514e-02 7.23096627e-01 3.11998342 0.82994049 725.00 -7.61307544e-01 3.54938737e-02 7.62134497e-01 3.09500414 0.89704860 725.25 -7.90772802e-01 4.14188039e-02 7.91856768e-01 3.08926284 0.90435408 725.50 -8.87214552e-01 6.39549479e-02 8.89516665e-01 3.06963203 0.91545949 725.75 -8.85925225e-01 1.04132111e-01 8.92024103e-01 3.02458900 0.91525868 726.00 -8.98455957e-01 2.09317917e-01 9.22516719e-01 2.91270043 0.94312532 726.25 -9.28804445e-01 2.65981915e-01 9.66138745e-01 2.86268669 0.92952176 726.50 -9.18088504e-01 4.11815985e-01 1.00622011e+00 2.71993851 0.93255744 726.75 -8.11162484e-01 5.21303528e-01 9.64231271e-01 2.57039307 0.89047064 727.00 -6.92188012e-01 6.53892352e-01 9.52207673e-01 2.38463658 0.91889904 727.25 -5.93007716e-01 7.14813875e-01 9.28771784e-01 2.26332572 0.90445926 727.50 -4.26160153e-01 7.68234233e-01 8.78519386e-01 2.07726135 0.93079638 727.75 -3.17529734e-01 7.65088820e-01 8.28363468e-01 1.96418642 0.91036496 728.00 -2.27894692e-01 6.99328874e-01 7.35524890e-01 1.88582059 0.90865477 728.25 -1.21133026e-01 6.80359098e-01 6.91058400e-01 1.74699283 0.86910628 728.50 -2.70695663e-02 6.59967760e-01 6.60522676e-01 1.61178985 0.89399140 728.75 7.12867339e-04 5.73321533e-01 5.73321976e-01 1.56955293 0.79796374 729.00 4.89140215e-02 4.49456573e-01 4.52110376e-01 1.46239370 0.78286933 729.25 -1.18551165e-02 3.93314926e-01 3.93493551e-01 1.60092874 0.76037208 729.50 -3.04805833e-02 3.44065023e-01 3.45412516e-01 1.65915526 0.82515099 729.75 -8.56851834e-02 3.11984561e-01 3.23537196e-01 1.83883301 0.78284249 730.00 -1.07471105e-01 3.20188238e-01 3.37743314e-01 1.89463021 0.84225710 730.25 -9.54310720e-02 3.30892185e-01 3.44378756e-01 1.85158217 0.78982464 730.50 -7.01215006e-02 3.29656493e-01 3.37031791e-01 1.78038342 0.79168899 730.75 -3.80570120e-02 3.03164290e-01 3.05543651e-01 1.69567573 0.76154376 731.00 -2.05974957e-02 2.82936922e-01 2.83685668e-01 1.64346703 0.70980242 731.25 1.44505885e-04 2.52198426e-01 2.52198467e-01 1.57022334 0.62375747 731.50 -3.55586706e-02 2.37362239e-01 2.40010940e-01 1.71949812 0.58169656 731.75 -5.27673832e-02 2.37912023e-01 2.43693511e-01 1.78905686 0.65085668 732.00 -6.93578186e-02 2.09858881e-01 2.21023204e-01 1.88999239 0.68974580 732.25 -1.04539909e-01 2.23115144e-01 2.46391884e-01 2.00896636 0.78679669 732.50 -1.29986311e-01 2.30902640e-01 2.64976358e-01 2.08352648 0.86065313 732.75 -1.10557056e-01 2.94831608e-01 3.14878611e-01 1.92955273 0.90507078 733.00 -1.04038631e-01 3.16731736e-01 3.33381207e-01 1.88816852 0.93668609 733.25 -9.92992721e-02 3.28173805e-01 3.42867892e-01 1.86461964 0.93338710 733.50 -8.98704913e-02 3.36487903e-01 3.48282664e-01 1.83178818 0.93002772 733.75 -4.15892031e-02 4.04775769e-01 4.06906727e-01 1.67318332 0.92121267 734.00 -1.57649008e-02 4.16986360e-01 4.17284263e-01 1.60858508 0.92234497 734.25 3.44268748e-02 4.44278784e-01 4.45610646e-01 1.49346152 0.89028993 734.50 6.26205931e-02 4.80020927e-01 4.84088245e-01 1.44107501 0.89857181 734.75 1.19401596e-01 5.00623846e-01 5.14665888e-01 1.33666482 0.85376921 735.00 1.55643808e-01 4.70010507e-01 4.95110969e-01 1.25101239 0.79001199 735.25 2.20754850e-01 3.61048521e-01 4.23188774e-01 1.02201689 0.64662296 735.50 2.16457098e-01 3.46483460e-01 4.08539426e-01 1.01239434 0.63990891 735.75 2.16139177e-01 3.16200031e-01 3.83012537e-01 0.97119477 0.49714135 736.00 1.98925334e-01 3.24774009e-01 3.80853574e-01 1.02123351 0.51501057 736.25 1.06939823e-01 3.12704488e-01 3.30484829e-01 1.24128079 0.43086210 736.50 4.14228265e-02 3.12667946e-01 3.15399897e-01 1.43908150 0.36732020 736.75 -2.44591703e-02 2.87495912e-01 2.88534487e-01 1.65566854 0.38173088 737.00 -6.93130073e-02 3.31073106e-01 3.38250934e-01 1.77717415 0.46514274 737.25 -1.33998506e-01 3.97773848e-01 4.19737577e-01 1.89572747 0.56257017 737.50 -1.39637654e-01 4.06111538e-01 4.29447617e-01 1.90197347 0.54938464 737.75 -6.59115705e-02 4.02757368e-01 4.08114974e-01 1.73300923 0.48867299 738.00 -9.13118740e-02 4.10605899e-01 4.20636497e-01 1.78961872 0.53901488 738.25 -1.09434413e-01 4.26063642e-01 4.39893303e-01 1.82221151 0.68985671 738.50 -4.46943347e-02 4.06313636e-01 4.08764424e-01 1.68035545 0.61961939 738.75 1.33504429e-02 2.91276789e-01 2.91582582e-01 1.52499417 0.41411957 739.00 -9.83338840e-02 2.15767228e-01 2.37118218e-01 1.99841386 0.31461018 739.25 -2.12109926e-01 1.41531436e-01 2.54993663e-01 2.55318276 0.54561193 739.50 -1.88126975e-01 1.78110689e-01 2.59065969e-01 2.38353682 0.51387964 739.75 -1.12418252e-01 1.90497964e-01 2.21195248e-01 2.10392565 0.43385904 740.00 -1.00311016e-01 1.18224481e-01 1.55046212e-01 2.27440684 0.22405211 740.25 -4.96749523e-02 4.34968277e-02 6.60270771e-02 2.42240653 0.06951438 740.50 -2.35578833e-02 -2.76415349e-02 3.63184294e-02 -2.27660326 0.01588619 740.75 6.05886850e-02 -5.39128936e-02 8.11023357e-02 -0.72716104 0.07808060 741.00 1.05307400e-01 -5.86924283e-02 1.20558906e-01 -0.50846397 0.10440954 741.25 4.58004138e-02 -1.09430863e-01 1.18628798e-01 -1.17441612 0.09690012 741.50 1.35143982e-01 -1.64663430e-01 2.13020987e-01 -0.88354318 0.26990594 741.75 2.59363317e-01 -2.83090226e-01 3.83939326e-01 -0.82911028 0.50646094 742.00 3.32214512e-01 -3.21507708e-01 4.62313409e-01 -0.76902141 0.44334739 742.25 1.84643350e-01 -3.10923780e-01 3.61616875e-01 -1.03490815 0.28556889 742.50 1.70549836e-01 -1.33600678e-01 2.16648074e-01 -0.66450741 0.14180023 742.75 2.59420599e-01 -5.90387728e-02 2.66053799e-01 -0.22376815 0.19043676 743.00 1.33700477e-01 -1.95004484e-01 2.36437235e-01 -0.96978147 0.21281121 743.25 1.04816451e-01 -2.01777569e-01 2.27377826e-01 -1.09169800 0.20046065 743.50 1.94907527e-01 -1.56184526e-01 2.49764990e-01 -0.67554913 0.20218460 743.75 2.45043629e-01 -1.80662746e-01 3.04442782e-01 -0.63530250 0.27467703 744.00 3.26588710e-01 -3.85281225e-01 5.05076042e-01 -0.86766047 0.48825919 744.25 3.22317348e-01 -3.94961725e-01 5.09787443e-01 -0.88633171 0.56545626 744.50 2.59592499e-01 -3.27435558e-01 4.17854413e-01 -0.90045810 0.64180856 744.75 2.66196488e-01 -3.54630081e-01 4.43421994e-01 -0.92689122 0.70187606 745.00 1.31576282e-01 -3.72286819e-01 3.94854142e-01 -1.23107161 0.59031884 745.25 4.66940043e-02 -3.34661053e-01 3.37902872e-01 -1.43216505 0.56334077 745.50 -4.11667486e-02 -2.76059423e-01 2.79111996e-01 -1.71882825 0.57364682 745.75 -8.48979984e-02 -1.88222191e-01 2.06483082e-01 -1.99452477 0.41568828 746.00 -8.57520703e-02 -6.20288116e-02 1.05834734e-01 -2.51536644 0.11194072 746.25 -3.66383616e-02 -2.10763687e-02 4.22679885e-02 -2.61956741 0.01361791 746.50 -2.27107428e-02 6.82474623e-02 7.19270043e-02 1.89204025 0.02913425 746.75 4.02485907e-02 1.19889497e-01 1.26465175e-01 1.24690464 0.05965519 747.00 1.34554796e-01 1.75667102e-01 2.21277934e-01 0.91715587 0.07919623 747.25 2.41971075e-01 1.25682613e-01 2.72664850e-01 0.47905612 0.09612716 747.50 1.88654866e-01 -3.16148873e-02 1.91285545e-01 -0.16603773 0.06426315 747.75 3.30967072e-01 8.01182652e-02 3.40526268e-01 0.23750436 0.20841693 748.00 5.28317697e-01 2.36511255e-01 5.78841224e-01 0.42091346 0.36618007 748.25 6.42594899e-01 1.71289340e-01 6.65032512e-01 0.26050170 0.41479876 748.50 9.11018166e-01 -1.15745885e-01 9.18341553e-01 -0.12637405 0.51136390 748.75 1.03233773e+00 -1.40360232e-01 1.04183597e+00 -0.13513484 0.53620864 749.00 9.67269456e-01 3.35982578e-02 9.67852801e-01 0.03472120 0.52436831 749.25 9.89402021e-01 -2.22418596e-01 1.01409388e+00 -0.22112505 0.54654226 749.50 8.87410461e-01 -5.95068435e-01 1.06845860e+00 -0.59069818 0.60915978 749.75 8.33556993e-01 -7.70420964e-01 1.13506199e+00 -0.74605632 0.64760914 750.00 7.77545791e-01 -9.94829848e-01 1.26264163e+00 -0.90738428 0.75895676 750.25 5.36640574e-01 -1.41015861e+00 1.50881755e+00 -1.20716588 0.76841291 750.50 1.25192577e-01 -1.64984593e+00 1.65458901e+00 -1.49506009 0.80413249 750.75 -3.39325818e-01 -1.73308988e+00 1.76599619e+00 -1.76414286 0.77903264 751.00 -9.09181241e-01 -1.70400607e+00 1.93138479e+00 -2.06092634 0.78717289 751.25 -1.16134449e+00 -1.47490110e+00 1.87724646e+00 -2.23781007 0.68074901 751.50 -1.39943511e+00 -1.09527787e+00 1.77709095e+00 -2.47751645 0.59635221 751.75 -1.46471154e+00 -8.97185780e-01 1.71765020e+00 -2.59200784 0.60841615 752.00 -1.41456396e+00 -1.06667260e+00 1.77166070e+00 -2.49549528 0.54250471 752.25 -1.45940648e+00 -1.29705345e+00 1.95248942e+00 -2.41502563 0.62854036 752.50 -1.38359802e+00 -1.12872007e+00 1.78559583e+00 -2.45729987 0.68424100 752.75 -1.37967508e+00 -9.81243633e-01 1.69302758e+00 -2.52338039 0.58833548 753.00 -1.23817659e+00 -7.59666920e-01 1.45264417e+00 -2.59127903 0.54637910 753.25 -1.26960082e+00 -4.72506487e-01 1.35467658e+00 -2.78530597 0.48758631 753.50 -1.47607298e+00 -1.74901438e-01 1.48639899e+00 -3.02365152 0.58080167 753.75 -1.14099258e+00 5.99638021e-01 1.28896463e+00 2.65772189 0.46383750 754.00 -8.97917695e-01 9.56648575e-01 1.31203380e+00 2.32453681 0.49813730 754.25 -5.95732403e-01 1.54891784e+00 1.65953113e+00 1.93796722 0.42787006 754.50 -8.17942059e-02 1.92542906e+00 1.92716563e+00 1.61325183 0.41279632 754.75 4.91076649e-01 2.50150832e+00 2.54925482e+00 1.37694921 0.53361943 755.00 5.42383667e-01 2.60942069e+00 2.66519350e+00 1.36585849 0.53460565 755.25 6.56275454e-01 1.77241380e+00 1.89001274e+00 1.21617706 0.27041750 755.50 9.99179925e-01 2.04567767e+00 2.27665493e+00 1.11644370 0.30096691 755.75 1.75215430e+00 2.22550630e+00 2.83247647e+00 0.90384374 0.39430545 756.00 1.88708040e+00 2.04274864e+00 2.78098803e+00 0.82498943 0.40976563 756.25 2.17072331e+00 1.01115029e+00 2.39467422e+00 0.43592561 0.27022504 756.50 1.73013783e+00 -1.96957992e-01 1.74131254e+00 -0.11335150 0.13140127 756.75 1.01685061e+00 -1.32678868e+00 1.67163195e+00 -0.91688169 0.16099260 757.00 6.81810221e-01 -1.57162195e+00 1.71314352e+00 -1.16147392 0.19633348 757.25 8.19650237e-01 -2.26394688e+00 2.40775455e+00 -1.22343171 0.32202984 757.50 -1.16089812e-01 -2.83991473e+00 2.84228649e+00 -1.61165150 0.41710277 757.75 -1.27848170e+00 -3.36607321e+00 3.60068942e+00 -1.93378079 0.58834060 758.00 -1.46446545e+00 -2.94518034e+00 3.28918627e+00 -2.03223458 0.64949971 758.25 -1.71755318e+00 -2.79887605e+00 3.28385385e+00 -2.12119812 0.71601681 758.50 -1.81226808e+00 -2.72248001e+00 3.27050653e+00 -2.15810729 0.69023069 758.75 -1.83516040e+00 -2.38229862e+00 3.00718480e+00 -2.22718331 0.63804400 759.00 -2.25423522e+00 -2.03221120e+00 3.03503852e+00 -2.40794500 0.72672625 759.25 -2.45474044e+00 -1.96076705e+00 3.14171260e+00 -2.46760364 0.81078443 759.50 -2.50175205e+00 -1.63004782e+00 2.98593691e+00 -2.56411980 0.83558948 759.75 -2.57157306e+00 -1.06766958e+00 2.78440413e+00 -2.74806766 0.86480536 760.00 -2.46632379e+00 -5.17507324e-01 2.52003311e+00 -2.93476383 0.81303478 760.25 -2.43570335e+00 -6.80706673e-02 2.43665436e+00 -3.11365290 0.83630997 760.50 -1.81523816e+00 2.64674602e-01 1.83443240e+00 2.99680585 0.68171613 760.75 -1.35490005e+00 5.35982867e-01 1.45706272e+00 2.76489508 0.71344723 761.00 -1.04769166e+00 5.09295536e-01 1.16492050e+00 2.68911701 0.61351384 761.25 -8.42718901e-01 4.08145984e-01 9.36353720e-01 2.69056720 0.50600534 761.50 -5.48696692e-01 2.88450586e-01 6.19896605e-01 2.65759601 0.26144541 761.75 -1.96362333e-01 1.98652943e-01 2.79322676e-01 2.35039577 0.07202353 762.00 1.48947332e-01 7.55364157e-02 1.67006161e-01 0.46933936 0.02605278 762.25 1.70073849e-02 -1.58222617e-01 1.59134056e-01 -1.46371724 0.02053802 762.50 -1.81957871e-01 -4.10445078e-01 4.48969742e-01 -1.98807999 0.05883620 762.75 -2.76847775e-01 -6.05668731e-01 6.65942417e-01 -1.99953426 0.08359196 763.00 -8.89357464e-01 -1.83476048e-01 9.08085986e-01 -2.93814508 0.20367036 763.25 -8.27888261e-01 -3.38438755e-02 8.28579737e-01 -3.10073564 0.18095434 763.50 -1.20445288e+00 2.05221827e-01 1.22181126e+00 2.97282743 0.37984536 763.75 -1.49748546e+00 3.16399937e-01 1.53054618e+00 2.93336767 0.50892013 764.00 -1.05763385e+00 8.01289641e-01 1.32689654e+00 2.49322950 0.49243040 764.25 -9.58782665e-01 9.09535390e-01 1.32155924e+00 2.38254754 0.54240337 764.50 -1.08337461e+00 1.12095078e+00 1.55891988e+00 2.33914958 0.75962136 764.75 -9.84297252e-01 1.17004498e+00 1.52900174e+00 2.27018704 0.84673124 765.00 -9.70528504e-01 1.00946668e+00 1.40033873e+00 2.33653123 0.85018210 765.25 -8.81218022e-01 1.01654003e+00 1.34532481e+00 2.28500873 0.87425714 765.50 -8.12434024e-01 1.09687241e+00 1.36498283e+00 2.20830741 0.90409653 765.75 -8.00453992e-01 1.06719149e+00 1.33402559e+00 2.21433364 0.90337253 766.00 -6.10219931e-01 1.05334970e+00 1.21733888e+00 2.09586644 0.87552555 766.25 -5.33993880e-01 1.08882153e+00 1.21271670e+00 2.02676099 0.88961365 766.50 -3.77606625e-01 1.17460664e+00 1.23381016e+00 1.88183665 0.91074424 766.75 -3.14772603e-01 1.11221753e+00 1.15590208e+00 1.84659728 0.89591345 767.00 -1.92183897e-01 8.91525298e-01 9.12004389e-01 1.78311487 0.84990089 767.25 -1.24070146e-01 8.43428511e-01 8.52505164e-01 1.71685099 0.78878938 767.50 -7.26307701e-02 7.06761812e-01 7.10483981e-01 1.67320240 0.68937913 767.75 -1.64858828e-01 6.39354736e-01 6.60267304e-01 1.82315124 0.62562565 768.00 -3.23389276e-01 4.78070367e-01 5.77175796e-01 2.16553942 0.53263816 768.25 -3.99821050e-01 4.89246127e-01 6.31837514e-01 2.25594861 0.63754455 768.50 -5.32717005e-01 5.14701226e-01 7.40746083e-01 2.37339297 0.67894203 768.75 -5.32220146e-01 5.76308339e-01 7.84467708e-01 2.31644362 0.64371727 769.00 -5.03202568e-01 7.18597995e-01 8.77266153e-01 2.18169409 0.67925975 769.25 -5.66280162e-01 6.60071317e-01 8.69693834e-01 2.27986325 0.65183737 769.50 -4.91817465e-01 4.36605789e-01 6.57654191e-01 2.41559275 0.41592148 769.75 -4.32666674e-01 3.61411486e-01 5.63754125e-01 2.44568802 0.34223450 770.00 -3.77713227e-01 2.50471868e-01 4.53214561e-01 2.55604454 0.32047829 770.25 -5.65615808e-01 1.60039289e-01 5.87821245e-01 2.86585331 0.39064727 770.50 -9.46749367e-01 2.59568899e-01 9.81687515e-01 2.87399960 0.55138480 770.75 -1.27567764e+00 3.48009541e-01 1.32229500e+00 2.87526950 0.68354832 771.00 -1.46756278e+00 3.98715278e-01 1.52076112e+00 2.87631067 0.69236943 771.25 -1.49839993e+00 8.69031943e-01 1.73217172e+00 2.61602884 0.72317925 771.50 -1.35947399e+00 1.36934473e+00 1.92957885e+00 2.35257729 0.75472452 771.75 -1.25392147e+00 1.51970434e+00 1.97023358e+00 2.26066112 0.57270154 772.00 -1.36252504e+00 1.86269558e+00 2.30783650e+00 2.20233906 0.56341188 772.25 -1.38959677e+00 2.17080853e+00 2.57747722e+00 2.14020079 0.55358897 772.50 -9.53378919e-01 2.45496127e+00 2.63358428e+00 1.94121756 0.44896386 772.75 7.43968205e-01 2.62365587e+00 2.72709714e+00 1.29448796 0.41681093 773.00 1.85325367e+00 2.21740445e+00 2.88988437e+00 0.87461814 0.44763570 773.25 2.01887506e+00 1.26731149e+00 2.38368096e+00 0.56056114 0.57756681 773.50 1.64224119e+00 9.81129519e-01 1.91300059e+00 0.53853006 0.60782773 773.75 1.49085585e+00 9.05184610e-01 1.74413599e+00 0.54566590 0.59852534 774.00 1.51209994e+00 8.08503135e-01 1.71467884e+00 0.49101215 0.57989608 774.25 1.65744097e+00 9.28793914e-01 1.89993914e+00 0.51077624 0.64993787 774.50 1.77230572e+00 9.54643220e-01 2.01306017e+00 0.49408341 0.69721942 774.75 1.75276734e+00 5.11320220e-01 1.82582631e+00 0.28384480 0.45336603 775.00 1.42009158e+00 -1.72464459e-01 1.43052581e+00 -0.12085417 0.32233316 775.25 1.39892755e+00 -9.16976353e-01 1.67267568e+00 -0.58022161 0.44932398 775.50 1.26666129e+00 -7.14949356e-01 1.45450452e+00 -0.51385899 0.38592987 775.75 9.33167848e-01 -8.94678526e-01 1.29276908e+00 -0.76434408 0.44127221 776.00 9.76183608e-01 -1.21423236e+00 1.55797775e+00 -0.89365073 0.49638739 776.25 3.67447795e-01 -1.83127632e+00 1.86777698e+00 -1.37277469 0.49611255 776.50 1.84808973e-01 -2.08583327e+00 2.09400449e+00 -1.48242510 0.56581253 776.75 3.09036118e-01 -1.90189160e+00 1.92683548e+00 -1.40971532 0.62811016 777.00 5.32249096e-02 -1.75446551e+00 1.75527266e+00 -1.54046881 0.60261513 777.25 -8.18082440e-01 -1.76816412e+00 1.94824619e+00 -2.00413930 0.57933126 777.50 -1.17863363e+00 -1.62822100e+00 2.01004499e+00 -2.19736880 0.56759261 777.75 -1.80031306e+00 -1.41753416e+00 2.29140355e+00 -2.47459309 0.64155256 778.00 -2.24275252e+00 -1.16350256e+00 2.52659397e+00 -2.66303157 0.60332469 778.25 -2.30426382e+00 -3.20633217e-01 2.32646457e+00 -3.00333264 0.64774623 778.50 -2.32510370e+00 -1.97149339e-02 2.32518728e+00 -3.13311369 0.63192755 778.75 -2.48009154e+00 7.05975283e-01 2.57861497e+00 2.86427081 0.62211230 779.00 -1.90670630e+00 6.80101805e-01 2.02436839e+00 2.79897099 0.50363293 779.25 -1.40418130e+00 1.25965205e+00 1.88638501e+00 2.41039746 0.60179003 779.50 -1.29666582e+00 1.51437411e+00 1.99365774e+00 2.27890118 0.64270836 779.75 -7.90611714e-01 2.14399330e+00 2.28512016e+00 1.92408214 0.72084459 780.00 -1.82986499e-01 2.49120363e+00 2.49791505e+00 1.64411770 0.76431507 780.25 2.75977196e-01 2.60703859e+00 2.62160516e+00 1.46533061 0.82206771 780.50 8.80308812e-01 2.17732934e+00 2.34855417e+00 1.18658281 0.81097541 780.75 1.48143309e+00 1.73026367e+00 2.27781834e+00 0.86272006 0.84627348 781.00 1.68246478e+00 1.31420440e+00 2.13490537e+00 0.66312134 0.81735049 781.25 1.69336354e+00 8.68110011e-01 1.90291752e+00 0.47371968 0.76354927 781.50 1.54949782e+00 4.08298619e-01 1.60238924e+00 0.25764722 0.72461787 781.75 1.55869909e+00 3.40015566e-03 1.55870280e+00 0.00218140 0.79345545 782.00 1.10737529e+00 -2.75847271e-01 1.14121504e+00 -0.24413150 0.63120805 782.25 9.69688842e-01 -5.03467090e-01 1.09260037e+00 -0.47889313 0.67478942 782.50 6.01010007e-01 -5.38528867e-01 8.06985978e-01 -0.73062281 0.56844424 782.75 3.59941336e-01 -5.78889187e-01 6.81667409e-01 -1.01451635 0.55738684 783.00 9.56509023e-02 -4.41194602e-01 4.51444097e-01 -1.35730052 0.46395308 783.25 -1.63351727e-02 -3.71186173e-01 3.71545438e-01 -1.61477598 0.47683995 783.50 -1.07808805e-01 -2.87790732e-01 3.07321076e-01 -1.92922357 0.48729363 783.75 -1.54414838e-01 -2.42580052e-01 2.87556992e-01 -2.13765967 0.48016032 784.00 -2.56997826e-01 -1.74812010e-01 3.10816861e-01 -2.54427369 0.59524954 784.25 -3.35812287e-01 -1.22398971e-01 3.57423279e-01 -2.79207120 0.69816773 784.50 -4.43433024e-01 1.23792168e-02 4.43605784e-01 3.11368313 0.79050290 784.75 -4.61919118e-01 7.97670535e-02 4.68755858e-01 2.97059292 0.84363013 785.00 -4.76515040e-01 1.98523142e-01 5.16215092e-01 2.74684586 0.87919971 785.25 -4.67884093e-01 2.55796184e-01 5.33242171e-01 2.64128006 0.87715765 785.50 -4.31549302e-01 3.72318424e-01 5.69961234e-01 2.42974395 0.85576910 785.75 -4.50129782e-01 3.97967498e-01 6.00828553e-01 2.41762218 0.88797666 786.00 -5.40359457e-01 4.10073444e-01 6.78342518e-01 2.49242612 0.93438620 786.25 -5.57600636e-01 4.94772028e-01 7.45464841e-01 2.41582557 0.93101323 786.50 -5.74060532e-01 6.16514784e-01 8.42398940e-01 2.32055099 0.93605507 786.75 -5.47769223e-01 7.12255395e-01 8.98531507e-01 2.22638650 0.93124710 787.00 -3.91577992e-01 8.95798006e-01 9.77643796e-01 1.98289412 0.96353839 787.25 -3.12498081e-01 9.38711537e-01 9.89360602e-01 1.89215780 0.95493622 787.50 -1.23575086e-01 1.04754485e+00 1.05480852e+00 1.68822003 0.94406786 787.75 -9.95153024e-03 1.09492185e+00 1.09496708e+00 1.57988488 0.93882870 788.00 1.98917062e-01 1.14750379e+00 1.16461708e+00 1.39915438 0.94163267 788.25 3.76062412e-01 1.04828307e+00 1.11369670e+00 1.22635550 0.91197931 788.50 6.78648974e-01 8.79000028e-01 1.11049785e+00 0.91331980 0.91707975 788.75 7.43830041e-01 7.00421958e-01 1.02170155e+00 0.75535145 0.89830377 789.00 7.30741902e-01 4.12111885e-01 8.38939767e-01 0.51350063 0.91355641 789.25 6.80226066e-01 2.71712381e-01 7.32485576e-01 0.38002718 0.85045285 789.50 5.58850738e-01 7.24664084e-02 5.63529527e-01 0.12895089 0.86445953 789.75 4.61664285e-01 8.65886337e-02 4.69714278e-01 0.18540357 0.81280255 790.00 3.22849469e-01 6.87855683e-02 3.30095795e-01 0.20991895 0.78137979 790.25 2.43024453e-01 8.47760356e-02 2.57386598e-01 0.33563878 0.64981485 790.50 1.69418061e-01 1.37727818e-01 2.18337884e-01 0.68258544 0.62396525 790.75 1.95435400e-01 1.36080067e-01 2.38144452e-01 0.60823290 0.69603578 791.00 2.56465935e-01 1.06910120e-01 2.77857067e-01 0.39495495 0.80525649 791.25 2.40013826e-01 5.36993420e-02 2.45947669e-01 0.22010947 0.75786524 791.50 1.64567609e-01 -8.24582603e-03 1.64774062e-01 -0.05006414 0.62296809 791.75 9.00559090e-02 -2.10972776e-02 9.24941181e-02 -0.23011879 0.40145294 792.00 3.74996781e-02 -3.13381075e-03 3.76303950e-02 -0.08337527 0.11475185 792.25 -3.28049909e-03 1.72668401e-02 1.75757060e-02 1.75854706 0.01956482 792.50 -3.83989008e-02 4.82306249e-02 6.16495641e-02 2.24318642 0.21632121 792.75 -4.48812377e-02 9.99470912e-02 1.09561611e-01 1.99285992 0.45664763 793.00 -5.94580976e-02 1.38324901e-01 1.50562424e-01 1.97676253 0.68058380 793.25 -6.93721592e-02 1.84497989e-01 1.97109118e-01 1.93044777 0.67072751 793.50 -3.62428069e-02 2.36815795e-01 2.39573083e-01 1.72266018 0.70705544 793.75 9.55298295e-03 1.85715404e-01 1.85960938e-01 1.51940279 0.56261061 794.00 9.21989386e-03 1.46048914e-01 1.46339645e-01 1.50775118 0.47830181 794.25 -7.21449275e-02 1.09660140e-01 1.31263997e-01 2.15270207 0.31319412 794.50 -1.46378613e-01 7.68339249e-02 1.65318330e-01 2.65822517 0.40300442 794.75 -2.79775573e-01 1.18469822e-01 3.03824736e-01 2.74103907 0.59663306 795.00 -3.09329755e-01 2.15850876e-01 3.77195570e-01 2.53234348 0.72321398 795.25 -2.71080032e-01 3.72419563e-01 4.60630779e-01 2.19999545 0.78675940 795.50 -2.37264640e-01 4.60257032e-01 5.17813716e-01 2.04677058 0.82461115 795.75 -1.16904299e-01 5.24165976e-01 5.37044305e-01 1.79023411 0.76019367 796.00 -3.77344827e-02 5.49947265e-01 5.51240315e-01 1.63930368 0.82056424 796.25 2.74899238e-02 5.65595819e-01 5.66263478e-01 1.52223107 0.83689541 796.50 7.67288939e-02 5.66628448e-01 5.71799896e-01 1.43620195 0.80678669 796.75 1.35003980e-01 5.72247769e-01 5.87957127e-01 1.33911388 0.80090378 797.00 1.89176754e-01 5.43296221e-01 5.75290038e-01 1.23572431 0.83073287 797.25 2.57358499e-01 4.99076755e-01 5.61525604e-01 1.09469210 0.87769005 797.50 2.90681948e-01 4.83300025e-01 5.63981302e-01 1.02930959 0.86965167 797.75 2.95104405e-01 4.41534833e-01 5.31074024e-01 0.98162204 0.88129453 798.00 2.89977831e-01 4.53293812e-01 5.38110047e-01 1.00168694 0.85560801 798.25 2.75484883e-01 4.96529319e-01 5.67832092e-01 1.06425933 0.85359824 798.50 3.36002478e-01 5.13132015e-01 6.13353185e-01 0.99104921 0.84431797 798.75 4.47972746e-01 5.79690500e-01 7.32612215e-01 0.91287522 0.89844055 799.00 5.59929184e-01 6.10459561e-01 8.28360771e-01 0.82854538 0.87107890 799.25 7.70098455e-01 5.78030787e-01 9.62897305e-01 0.64388075 0.87396563 799.50 8.46869546e-01 5.55252358e-01 1.01266639e+00 0.58033879 0.82260412 799.75 1.14414884e+00 5.95463530e-01 1.28982688e+00 0.47986744 0.81410574 800.00 1.29671735e+00 4.54848197e-01 1.37417713e+00 0.33735970 0.76309319 800.25 1.45114291e+00 2.79960309e-01 1.47790173e+00 0.19058256 0.67124624 800.50 1.39612343e+00 -1.33284045e-02 1.39618705e+00 -0.00954643 0.41782196 800.75 9.64021909e-01 -6.68712647e-01 1.17324969e+00 -0.60646469 0.17545050 801.00 -3.83840800e-01 -6.46701533e-01 7.52034994e-01 -2.10644951 0.09498538 801.25 -1.27717392e+00 -5.30557185e-01 1.38299102e+00 -2.74786853 0.43477437 801.50 -1.06951228e+00 3.83312322e-02 1.07019896e+00 3.10576807 0.47660705 801.75 -8.97862242e-01 3.66231235e-01 9.69681352e-01 2.75430101 0.73342454 802.00 -6.52493612e-01 3.94410303e-01 7.62435178e-01 2.59789569 0.79102997 802.25 -4.71013039e-01 2.86606485e-01 5.51358831e-01 2.59495425 0.78168305 802.50 -3.13317129e-01 1.39633675e-01 3.43023595e-01 2.72235170 0.80192983 802.75 -2.63645876e-01 9.64243699e-02 2.80725501e-01 2.79096988 0.89563334 803.00 -2.48274636e-01 1.83171898e-02 2.48949422e-01 3.06794815 0.87654966 803.25 -2.45814126e-01 -2.31883252e-02 2.46905413e-01 -3.04753822 0.91854675 803.50 -2.54803645e-01 -4.88086502e-02 2.59436277e-01 -2.95233131 0.89257330 803.75 -2.86496123e-01 -6.60871082e-02 2.94019615e-01 -2.91488455 0.91702370 804.00 -3.37091767e-01 -5.77267460e-02 3.41998884e-01 -2.97198849 0.93216371 804.25 -3.66146750e-01 -3.85828837e-02 3.68173983e-01 -3.03660464 0.94753819 804.50 -4.17198029e-01 5.81359221e-03 4.17238533e-01 3.12765870 0.95510717 804.75 -4.26763037e-01 2.68873590e-02 4.27609191e-01 3.07867280 0.96401529 805.00 -3.93050398e-01 6.15891717e-02 3.97846505e-01 2.98616120 0.94917370 805.25 -3.69918827e-01 6.99072266e-02 3.76466411e-01 2.95481544 0.95188525 805.50 -3.72714940e-01 7.13408888e-02 3.79481158e-01 2.95247142 0.97584395 805.75 -3.73619032e-01 6.95888174e-02 3.80044451e-01 2.95744664 0.97764059 806.00 -4.01423000e-01 8.61907558e-02 4.10571883e-01 2.93009078 0.98104677 806.25 -4.15654439e-01 9.68766648e-02 4.26794682e-01 2.91261028 0.98485920 806.50 -4.41389747e-01 1.41873818e-01 4.63630337e-01 2.83059737 0.98337341 806.75 -4.39553384e-01 1.62727915e-01 4.68708387e-01 2.78702632 0.99120630 807.00 -4.36646053e-01 1.97714551e-01 4.79323293e-01 2.71641037 0.99091099 807.25 -4.24627395e-01 2.07890586e-01 4.72786337e-01 2.68631288 0.99107893 807.50 -4.13832372e-01 2.15754056e-01 4.66698023e-01 2.66100645 0.99183749 807.75 -4.08185196e-01 2.29953046e-01 4.68501395e-01 2.62855417 0.99013512 808.00 -3.94394507e-01 2.51244624e-01 4.67622592e-01 2.57438299 0.99034023 808.25 -3.81190932e-01 2.57084494e-01 4.59781430e-01 2.54823847 0.98770227 808.50 -3.56655404e-01 2.50706738e-01 4.35955211e-01 2.52889741 0.98901841 808.75 -3.51549930e-01 2.37476209e-01 4.24243213e-01 2.54749131 0.98416096 809.00 -3.58959340e-01 1.91714766e-01 4.06947613e-01 2.65105038 0.97723986 809.25 -3.92132294e-01 1.74336706e-01 4.29139865e-01 2.72324974 0.97214683 809.50 -4.69551831e-01 1.94229064e-01 5.08137630e-01 2.74937661 0.97013629 809.75 -4.99069568e-01 2.33193731e-01 5.50862732e-01 2.70448087 0.97847614 810.00 -5.18384025e-01 2.86047509e-01 5.92068556e-01 2.63736380 0.96552424 810.25 -5.07358286e-01 3.32844526e-01 6.06793135e-01 2.56098696 0.95937559 810.50 -4.42149145e-01 3.64766255e-01 5.73193063e-01 2.45180175 0.95859865 810.75 -4.06979402e-01 3.42347977e-01 5.31821747e-01 2.44223413 0.93797821 811.00 -4.19435517e-01 3.09958492e-01 5.21536595e-01 2.50517551 0.93185905 811.25 -4.33963653e-01 2.57362863e-01 5.04539489e-01 2.60629790 0.90904186 811.50 -5.08715945e-01 1.83461962e-01 5.40786654e-01 2.79547298 0.89078433 811.75 -6.46267426e-01 1.49738862e-01 6.63387755e-01 2.91391219 0.92270890 812.00 -7.51896325e-01 1.39283292e-01 7.64688119e-01 2.95842625 0.93313934 812.25 -9.03158835e-01 2.11063857e-01 9.27493306e-01 2.91201759 0.90183158 812.50 -1.09426581e+00 3.84985228e-01 1.16001349e+00 2.80329686 0.91582030 812.75 -1.12071304e+00 5.81105848e-01 1.26241108e+00 2.66324347 0.87451903 813.00 -1.21198133e+00 8.10271644e-01 1.45788850e+00 2.55228647 0.86828904 813.25 -1.14369860e+00 1.12993008e+00 1.60772774e+00 2.36225017 0.74138230 813.50 -8.58636414e-01 1.60212757e+00 1.81770989e+00 2.06277707 0.62902086 813.75 5.27749083e-01 1.76585700e+00 1.84303284e+00 1.28038310 0.66437468 814.00 1.02203052e+00 1.30918768e+00 1.66087891e+00 0.90795978 0.79586897 814.25 7.65348336e-01 8.77469789e-01 1.16435016e+00 0.85354195 0.88331514 814.50 6.46972941e-01 8.01864046e-01 1.03032031e+00 0.89190085 0.94466395 814.75 4.47840696e-01 7.38608709e-01 8.63773184e-01 1.02573533 0.94845455 815.00 3.43734926e-01 7.39551062e-01 8.15530179e-01 1.13571246 0.95803775 815.25 3.01760701e-01 7.29706243e-01 7.89639615e-01 1.17867467 0.96118563 815.50 2.98942831e-01 7.14846094e-01 7.74836598e-01 1.17470632 0.96975240 815.75 2.46327495e-01 6.75829865e-01 7.19321375e-01 1.22127908 0.95300422 816.00 1.98752383e-01 6.80676971e-01 7.09100592e-01 1.28670221 0.95693326 816.25 1.78930713e-01 6.92039738e-01 7.14797313e-01 1.31778173 0.94849772 816.50 2.33899705e-01 6.87937997e-01 7.26613900e-01 1.24305680 0.94757391 816.75 2.55563558e-01 7.14778368e-01 7.59092121e-01 1.22741810 0.95920216 817.00 2.68934952e-01 6.80395523e-01 7.31617439e-01 1.19438051 0.94877524 817.25 3.01133408e-01 6.50044552e-01 7.16407181e-01 1.13697815 0.95722188 817.50 3.13025508e-01 6.29961590e-01 7.03446212e-01 1.10963485 0.95809972 817.75 2.80874347e-01 5.59536737e-01 6.26076480e-01 1.10556869 0.95124068 818.00 2.50772184e-01 5.33969471e-01 5.89923796e-01 1.13173224 0.95106995 818.25 2.11269100e-01 4.93485409e-01 5.36807676e-01 1.16628919 0.93729124 818.50 1.76108457e-01 4.75380090e-01 5.06952087e-01 1.21601343 0.92822229 818.75 9.87318418e-02 4.78499040e-01 4.88578865e-01 1.36731542 0.91513653 819.00 3.97953714e-02 4.67179265e-01 4.68871131e-01 1.48581923 0.89086820 819.25 -5.06626772e-02 4.59341545e-01 4.62126998e-01 1.68064646 0.88897707 819.50 -1.24867450e-01 4.46863892e-01 4.63981916e-01 1.84327696 0.87283866 819.75 -2.03608027e-01 4.54843432e-01 4.98336007e-01 1.99168945 0.82541561 820.00 -2.78113949e-01 4.20968795e-01 5.04541471e-01 2.15462348 0.64405221 820.25 -4.08255731e-01 9.43059532e-02 4.19006390e-01 2.91457732 0.37271802 820.50 -2.60748550e-01 6.83168459e-05 2.60748559e-01 3.14133065 0.10513284 820.75 5.58866978e-02 1.63395798e-01 1.72689055e-01 1.24123693 0.02831042 821.00 3.28975982e-01 2.27258928e-01 3.99839740e-01 0.60452952 0.13471139 821.25 5.42282725e-01 3.39799204e-01 6.39948477e-01 0.55975547 0.26133767 821.50 4.22702692e-01 2.39291012e-01 4.85734243e-01 0.51511821 0.15292220 821.75 5.62296317e-01 1.78943910e-01 5.90083105e-01 0.30810356 0.23499136 822.00 4.82764761e-01 -6.38126128e-03 4.82806933e-01 -0.01321739 0.16515635 822.25 6.46308376e-01 -3.00080580e-01 7.12574818e-01 -0.43468146 0.35153578 822.50 5.81473799e-01 -2.89001253e-01 6.49333122e-01 -0.46125683 0.46699841 822.75 6.62586227e-01 -3.40263029e-01 7.44848600e-01 -0.47441905 0.70225370 823.00 6.23705174e-01 -2.67439947e-01 6.78625279e-01 -0.40507833 0.73968339 823.25 6.01121056e-01 -1.86852823e-01 6.29492257e-01 -0.30137238 0.84042480 823.50 6.00195282e-01 -1.26020939e-01 6.13282686e-01 -0.20696017 0.88472912 823.75 6.04696990e-01 -1.22328707e-01 6.16946320e-01 -0.19960374 0.94883236 824.00 6.02065315e-01 -9.26824274e-02 6.09157349e-01 -0.15274180 0.94534234 824.25 5.95226368e-01 -4.42604625e-02 5.96869682e-01 -0.07422244 0.95242833 824.50 5.59817603e-01 -2.90511941e-02 5.60570888e-01 -0.05184753 0.96725521 824.75 5.47570940e-01 -1.65702348e-02 5.47821601e-01 -0.03025212 0.97774808 825.00 5.46332303e-01 1.29645689e-02 5.46486108e-01 0.02372574 0.96471117 825.25 5.54897119e-01 2.71144126e-02 5.55559181e-01 0.04882502 0.96248304 825.50 5.86788770e-01 6.33429016e-02 5.90197750e-01 0.10753199 0.94277899 825.75 6.15753882e-01 8.02763830e-02 6.20964686e-01 0.12963972 0.95856805 826.00 6.63025378e-01 3.80338159e-02 6.64115368e-01 0.05730125 0.93431378 826.25 7.31857770e-01 2.23680183e-02 7.32199511e-01 0.03055383 0.94006240 826.50 7.30538844e-01 -1.11054728e-01 7.38931766e-01 -0.15086252 0.86867226 826.75 7.05772661e-01 -2.81846551e-01 7.59968768e-01 -0.37994131 0.82946105 827.00 4.92335447e-01 -3.67569150e-01 6.14411322e-01 -0.64131048 0.91822871 827.25 4.78143409e-01 -3.46028616e-01 5.90217691e-01 -0.62645038 0.96167803 827.50 4.50743226e-01 -2.97715965e-01 5.40189089e-01 -0.58372131 0.96809230 827.75 4.46132582e-01 -2.83359197e-01 5.28513685e-01 -0.56586186 0.96597128 828.00 4.17514145e-01 -2.95306550e-01 5.11394192e-01 -0.61560659 0.97729391 828.25 4.09883554e-01 -3.02949782e-01 5.09689217e-01 -0.63649618 0.98136029 828.50 3.91316700e-01 -3.35173728e-01 5.15237991e-01 -0.70827174 0.97999252 828.75 3.63083691e-01 -3.39606241e-01 4.97154066e-01 -0.75199976 0.97628315 829.00 3.28695240e-01 -3.46917611e-01 4.77904164e-01 -0.81236324 0.97581622 829.25 2.97660763e-01 -3.55537629e-01 4.63690560e-01 -0.87377271 0.97075070 829.50 2.44448530e-01 -3.65768455e-01 4.39933685e-01 -0.98165347 0.97805760 829.75 2.09355846e-01 -3.71998546e-01 4.26863899e-01 -1.05818908 0.96987582 830.00 1.32552315e-01 -3.61168428e-01 3.84724251e-01 -1.21904919 0.95794845 830.25 1.00519237e-01 -3.46723628e-01 3.61000542e-01 -1.28862036 0.96176762 830.50 5.34457738e-02 -3.07169831e-01 3.11784791e-01 -1.39852672 0.95402558 830.75 2.17682649e-02 -2.70544987e-01 2.71419320e-01 -1.49050849 0.92465029 831.00 -1.16475826e-02 -2.03336811e-01 2.03670137e-01 -1.62801601 0.90973901 831.25 -2.92488528e-02 -1.67540397e-01 1.70074337e-01 -1.74363242 0.78552997 831.50 -4.10864357e-02 -1.04545229e-01 1.12328982e-01 -1.94525502 0.75189006 831.75 -4.46769122e-02 -7.80463747e-02 8.99292115e-02 -2.09070501 0.56475974 832.00 -4.72180345e-02 -1.86409089e-02 5.07644193e-02 -2.76559119 0.30036480 832.25 -4.76676144e-02 3.56175912e-02 5.95047415e-02 2.49988125 0.22273646 832.50 -3.28999795e-02 1.00008671e-01 1.05281256e-01 1.88861590 0.57509652 832.75 -2.31141762e-02 1.36678433e-01 1.38619116e-01 1.73832482 0.64509148 833.00 -1.64496355e-02 1.78350791e-01 1.79107775e-01 1.66276804 0.75865251 833.25 -2.49476317e-02 2.28774907e-01 2.30131141e-01 1.67941594 0.64065157 833.50 5.12784812e-03 3.59869972e-01 3.59906504e-01 1.55654812 0.76709793 833.75 -6.88239340e-03 4.24913812e-01 4.24969546e-01 1.58699206 0.67252834 834.00 -8.47558634e-02 5.22455670e-01 5.29285824e-01 1.73162121 0.64029314 834.25 -3.80441328e-01 4.66702361e-01 6.02118508e-01 2.25471850 0.42233346 834.50 -6.04777212e-01 2.34869520e-01 6.48782836e-01 2.77116338 0.37001262 834.75 -3.93279547e-01 -2.77858108e-01 4.81532896e-01 -2.52650722 0.38658620 835.00 -3.43469799e-01 -4.08626237e-01 5.33804182e-01 -2.26977712 0.74166605 835.25 -2.45613227e-01 -3.92967819e-01 4.63410794e-01 -2.12941090 0.78382554 835.50 -1.60426902e-01 -3.67117991e-01 4.00640001e-01 -1.98277865 0.81716136 835.75 -1.13203117e-01 -3.25439185e-01 3.44565827e-01 -1.90555202 0.83299601 836.00 -8.42839699e-02 -3.06490479e-01 3.17868214e-01 -1.83915977 0.88142715 836.25 -1.28685155e-02 -2.39907940e-01 2.40252821e-01 -1.62438436 0.77522153 836.50 2.26772349e-02 -2.39485465e-01 2.40556739e-01 -1.47638634 0.79679163 836.75 7.05267468e-02 -2.69409642e-01 2.78488020e-01 -1.31475930 0.74536953 837.00 9.31046925e-02 -3.09958069e-01 3.23639442e-01 -1.27899246 0.71457672 837.25 1.20214080e-01 -3.96036972e-01 4.13880065e-01 -1.27609265 0.75969799 837.50 1.26140132e-01 -4.44056498e-01 4.61624855e-01 -1.29402376 0.77985816 837.75 1.57431931e-02 -5.63332988e-01 5.63552929e-01 -1.54285709 0.81562269 838.00 -7.32724474e-02 -5.83618577e-01 5.88200217e-01 -1.69569136 0.82345115 838.25 -2.00517449e-01 -6.11379402e-01 6.43422117e-01 -1.88771708 0.88617593 838.50 -2.45324443e-01 -6.07231693e-01 6.54915576e-01 -1.95475024 0.88480222 838.75 -4.10860072e-01 -5.67751948e-01 7.00819715e-01 -2.19722644 0.83689102 839.00 -4.70221174e-01 -5.34493331e-01 7.11892600e-01 -2.29231097 0.85242561 839.25 -4.55573298e-01 -4.65152565e-01 6.51086736e-01 -2.34579083 0.89326620 839.50 -4.98253827e-01 -4.54514368e-01 6.74418407e-01 -2.40207005 0.87793471 839.75 -6.30182062e-01 -3.86462496e-01 7.39244677e-01 -2.59148357 0.88927358 840.00 -6.67025800e-01 -3.06756543e-01 7.34181854e-01 -2.71054712 0.90691859 840.25 -7.09158549e-01 -2.02758080e-01 7.37574869e-01 -2.86310872 0.90571111 840.50 -7.29588851e-01 -1.07022456e-01 7.37396567e-01 -2.99594268 0.91266921 840.75 -6.98386449e-01 -3.79085471e-02 6.99414534e-01 -3.08736568 0.93286539 841.00 -6.94992096e-01 -1.25045731e-02 6.95104580e-01 -3.12360220 0.91138481 841.25 -6.79290337e-01 2.60827003e-02 6.79790901e-01 3.10321452 0.89969557 841.50 -6.69321417e-01 7.77211431e-02 6.73818770e-01 3.02599106 0.88521093 841.75 -7.02878762e-01 1.55267237e-01 7.19823915e-01 2.92418227 0.91679544 842.00 -7.21857006e-01 2.46750257e-01 7.62865143e-01 2.81221732 0.90928596 842.25 -7.41016881e-01 3.57187813e-01 8.22611179e-01 2.69242910 0.94296254 842.50 -6.72194774e-01 3.97257342e-01 7.80806769e-01 2.60782785 0.91901609 842.75 -5.77031862e-01 4.95617889e-01 7.60659491e-01 2.43194911 0.93786846 843.00 -5.19280444e-01 5.48713262e-01 7.55472318e-01 2.32864248 0.95029407 843.25 -4.46241374e-01 5.56947903e-01 7.13668222e-01 2.24628464 0.93416764 843.50 -4.00433311e-01 5.53121689e-01 6.82854625e-01 2.19741696 0.93398608 843.75 -3.54802296e-01 5.66801675e-01 6.68691863e-01 2.13009471 0.93845134 844.00 -2.93839665e-01 5.24135284e-01 6.00882305e-01 2.08175497 0.91190680 844.25 -2.36843329e-01 4.97123287e-01 5.50659900e-01 2.01540893 0.92450155 844.50 -1.90912820e-01 5.00412938e-01 5.35593888e-01 1.93526263 0.88036956 844.75 -1.85456595e-01 5.29173094e-01 5.60730160e-01 1.90788525 0.87464226 845.00 -1.30705206e-01 5.62685917e-01 5.77667111e-01 1.79903670 0.86904547 845.25 -9.32015570e-02 5.39604659e-01 5.47594484e-01 1.74183076 0.85791068 845.50 -1.02170087e-01 4.96018511e-01 5.06431723e-01 1.77393559 0.84435673 845.75 -8.01616030e-02 4.48737591e-01 4.55841319e-01 1.74756973 0.75779128 846.00 1.17371707e-02 4.32406448e-01 4.32565714e-01 1.54365915 0.75380299 846.25 9.87497749e-03 4.24820380e-01 4.24935137e-01 1.54755545 0.83845980 846.50 8.30593690e-03 3.98479162e-01 3.98565718e-01 1.54995525 0.82033305 846.75 4.49200791e-03 3.91205629e-01 3.91231417e-01 1.55931436 0.82713497 847.00 3.78824037e-02 3.28501796e-01 3.30678857e-01 1.45598476 0.80165976 847.25 4.39704526e-02 2.90141607e-01 2.93454516e-01 1.42039254 0.78798780 847.50 3.12577521e-02 3.12411756e-01 3.13971579e-01 1.47107514 0.78789733 847.75 2.77743150e-02 3.14681202e-01 3.15904529e-01 1.48276270 0.81121529 848.00 4.35593651e-02 3.25980960e-01 3.28878404e-01 1.43795775 0.81062971 848.25 4.98093025e-02 3.21534465e-01 3.25369603e-01 1.41710671 0.77761300 848.50 4.97065066e-02 3.32237451e-01 3.35935204e-01 1.42228646 0.82162898 848.75 3.26460730e-02 3.22712442e-01 3.24359502e-01 1.46997781 0.77224547 849.00 1.10334131e-01 2.70268681e-01 2.91922559e-01 1.18320787 0.68674130 849.25 1.20221728e-01 3.06159351e-01 3.28917637e-01 1.19661880 0.64419097 849.50 1.39494444e-01 3.58610902e-01 3.84786277e-01 1.19982111 0.79703962 849.75 1.80473690e-01 3.72594671e-01 4.14001862e-01 1.11973070 0.77080798 850.00 2.91394086e-01 2.55960400e-01 3.87848217e-01 0.72075210 0.66282977 850.25 3.44448689e-01 1.77448457e-01 3.87469811e-01 0.47570713 0.64039886 850.50 4.43724901e-01 8.57366533e-02 4.51932032e-01 0.19086819 0.69794551 850.75 4.55629554e-01 1.03913766e-02 4.55748035e-01 0.02280268 0.71147967 851.00 3.74399963e-01 -1.12377784e-01 3.90901648e-01 -0.29159841 0.68962470 851.25 3.48991986e-01 -2.11904610e-01 4.08287852e-01 -0.54568985 0.63623769 851.50 2.89948628e-01 -4.13325505e-01 5.04884324e-01 -0.95906308 0.72317311 851.75 2.58983520e-01 -5.04248478e-01 5.66867702e-01 -1.09632565 0.73570675 852.00 1.44213726e-01 -5.75529001e-01 5.93322197e-01 -1.32527567 0.67737047 852.25 -3.88992642e-02 -6.45331311e-01 6.46502632e-01 -1.63100145 0.63332415 852.50 -2.13349611e-01 -7.11195364e-01 7.42507174e-01 -1.86224151 0.79164850 852.75 -2.29426607e-01 -7.77536584e-01 8.10678547e-01 -1.85772275 0.79984066 853.00 -3.43410368e-01 -8.76083016e-01 9.40984661e-01 -1.94437316 0.75753684 853.25 -3.71245098e-01 -9.01314281e-01 9.74777080e-01 -1.96151311 0.71519366 853.50 -4.07249909e-01 -1.01914630e+00 1.09750247e+00 -1.95095702 0.73994680 853.75 -6.81497795e-01 -1.01092081e+00 1.21918010e+00 -2.16395198 0.69164078 854.00 -9.09848277e-01 -1.22020117e+00 1.52207581e+00 -2.21151040 0.71953710 854.25 -9.51770446e-01 -1.22437229e+00 1.55079157e+00 -2.23157527 0.71272142 854.50 -9.09038762e-01 -1.17113990e+00 1.48253841e+00 -2.23085565 0.69216768 854.75 -7.46483570e-01 -1.14095653e+00 1.36345866e+00 -2.15016128 0.64088842 855.00 -8.83656756e-01 -1.28553479e+00 1.55995159e+00 -2.17300528 0.71227048 855.25 -7.81601413e-01 -1.35493070e+00 1.56420522e+00 -2.09402516 0.69998782 855.50 -6.05983545e-01 -1.47641665e+00 1.59593928e+00 -1.96027197 0.77501729 855.75 -3.21768061e-01 -1.35287987e+00 1.39061807e+00 -1.80429733 0.76088377 856.00 -2.41499569e-01 -1.32975386e+00 1.35150559e+00 -1.75045046 0.84987660 856.25 -4.86012442e-02 -1.20898909e+00 1.20996558e+00 -1.61097460 0.71594764 856.50 1.34838677e-01 -1.02962632e+00 1.03841794e+00 -1.44057853 0.63341139 856.75 2.52963363e-01 -8.25498605e-01 8.63387752e-01 -1.27344449 0.61101030 857.00 3.19164563e-01 -8.06122714e-01 8.67006256e-01 -1.19380735 0.61179524 857.25 3.63873739e-01 -6.80802432e-01 7.71943035e-01 -1.07994846 0.61351243 857.50 2.93322322e-01 -6.86500832e-01 7.46539602e-01 -1.16700317 0.59994066 857.75 3.02327832e-01 -5.99194276e-01 6.71145214e-01 -1.10350955 0.42120410 858.00 3.72024744e-01 -5.76358278e-01 6.85996556e-01 -0.99760885 0.43216609 858.25 5.10090197e-01 -3.42249986e-01 6.14269535e-01 -0.59096885 0.47693962 858.50 5.17739712e-01 -3.20788459e-01 6.09064565e-01 -0.55470246 0.44427071 858.75 5.67335876e-01 -2.43673814e-01 6.17451961e-01 -0.40568055 0.31937174 859.00 6.78392075e-01 -2.27804804e-01 7.15619198e-01 -0.32396990 0.36785704 859.25 6.93598331e-01 -2.26184027e-01 7.29546338e-01 -0.31522859 0.45146729 859.50 6.34971614e-01 -1.00773149e-01 6.42918485e-01 -0.15739230 0.39526543 859.75 7.33242712e-01 -1.46195031e-01 7.47674971e-01 -0.19680078 0.40802013 860.00 7.51122562e-01 -2.74744789e-01 7.99793600e-01 -0.35066202 0.36061481 860.25 8.24352709e-01 -2.74409372e-01 8.68825583e-01 -0.32134123 0.28044804 860.50 6.52165721e-01 -1.51565933e-01 6.69546384e-01 -0.22835042 0.14448595 860.75 1.12041184e+00 -2.98669523e-01 1.15953705e+00 -0.26051326 0.35863032 861.00 1.00959349e+00 -4.64786542e-01 1.11144300e+00 -0.43144407 0.31503419 861.25 7.10403393e-01 -3.80015765e-01 8.05658093e-01 -0.49119923 0.13350853 861.50 3.82012291e-01 -2.72560855e-01 4.69279032e-01 -0.61972050 0.04784217 861.75 2.21954867e-01 1.89716709e-01 2.91986973e-01 0.70724728 0.01479359 862.00 -1.25081602e-01 2.22993254e-01 2.55678310e-01 2.08198551 0.00763181 862.25 -5.97244652e-01 -1.62853914e-01 6.19049733e-01 -2.87538890 0.05385368 862.50 -6.23103706e-01 -3.80279341e-01 7.29979867e-01 -2.59363502 0.12675284 862.75 -1.06750601e+00 -3.72282231e-01 1.13055877e+00 -2.80604061 0.37698008 863.00 -1.40689501e+00 -3.99337271e-01 1.46247182e+00 -2.86502392 0.49390562 863.25 -1.60617210e+00 -1.07513873e+00 1.93279903e+00 -2.55171426 0.53077390 863.50 -1.21307843e+00 -1.03788474e+00 1.59648490e+00 -2.43386845 0.45266089 863.75 -9.41789480e-01 -6.99987810e-01 1.17343528e+00 -2.50242366 0.36251747 864.00 -1.07300964e+00 -4.81019663e-01 1.17589524e+00 -2.72016154 0.37206467 864.25 -1.16504498e+00 -5.61914446e-01 1.29347503e+00 -2.69219582 0.47276631 864.50 -1.05894676e+00 -6.83895042e-01 1.26058743e+00 -2.56815751 0.41997243 864.75 -1.01837088e+00 -8.17030776e-01 1.30561041e+00 -2.46545573 0.39979556 865.00 -1.03484102e+00 -7.62710815e-01 1.28554414e+00 -2.50644294 0.34823420 865.25 -1.15548554e+00 -6.68981216e-01 1.33517141e+00 -2.61678657 0.37218138 865.50 -1.37452289e+00 -4.86582241e-01 1.45810680e+00 -2.80135808 0.29766143 865.75 -1.41296054e+00 -5.90879678e-01 1.53153396e+00 -2.74550804 0.27041829 866.00 -8.88957330e-01 -5.26862820e-01 1.03335839e+00 -2.60657656 0.19910362 866.25 -8.85301627e-01 -8.45323443e-01 1.22406319e+00 -2.37929081 0.28496331 866.50 -8.69274591e-01 -1.17688930e+00 1.46311542e+00 -2.20697470 0.26071183 866.75 -5.02319356e-01 -7.62511339e-01 9.13098175e-01 -2.15331185 0.11617687 867.00 -3.52490004e-01 5.76053776e-02 3.57166043e-01 2.97960051 0.03513428 867.25 -6.18266071e-01 3.09823546e-01 6.91551563e-01 2.67705196 0.10818461 867.50 -7.83595809e-01 8.33765367e-01 1.14419713e+00 2.32518504 0.22379203 867.75 -6.89492616e-01 1.22740343e+00 1.40780654e+00 2.08261509 0.27127309 868.00 -7.81449880e-01 1.13524483e+00 1.37820344e+00 2.17366308 0.36859515 868.25 -6.97459106e-01 1.29121618e+00 1.46754503e+00 2.06605093 0.47026468 868.50 -5.46960585e-01 1.66617994e+00 1.75365945e+00 1.88798498 0.61008633 868.75 -4.85905498e-01 2.03161322e+00 2.08891274e+00 1.80555849 0.70496286 869.00 -1.51304032e-01 2.34412008e+00 2.34899805e+00 1.63525311 0.79838694 869.25 -3.95831176e-02 2.41672646e+00 2.41705060e+00 1.58717368 0.78270547 869.50 -7.31329247e-02 2.45840124e+00 2.45948879e+00 1.60053572 0.82278383 869.75 -3.94592543e-02 2.41749693e+00 2.41781894e+00 1.58711724 0.82812848 870.00 1.06522124e-01 2.32668544e+00 2.32912261e+00 1.52504550 0.80168043 870.25 2.20436107e-01 2.26897780e+00 2.27966058e+00 1.47394810 0.76981396 870.50 5.79161933e-01 2.32570983e+00 2.39673836e+00 1.32673469 0.77952671 870.75 6.95433656e-01 2.41260008e+00 2.51082996e+00 1.29015326 0.81276964 871.00 7.46850442e-01 2.26922584e+00 2.38896871e+00 1.25284143 0.82176453 871.25 8.21536538e-01 2.08344911e+00 2.23957194e+00 1.19519986 0.83208948 871.50 8.67711696e-01 1.87250090e+00 2.06377887e+00 1.13685730 0.80240859 871.75 9.32706618e-01 1.81186905e+00 2.03784472e+00 1.09539795 0.77601649 872.00 1.10300527e+00 1.73926396e+00 2.05952901e+00 1.00562335 0.83493880 872.25 1.16146689e+00 1.66068463e+00 2.02654356e+00 0.96047961 0.84438133 872.50 1.17322461e+00 1.64588953e+00 2.02123931e+00 0.95151740 0.90325898 872.75 1.17903209e+00 1.58347307e+00 1.97420962e+00 0.93076911 0.90141813 873.00 1.28513829e+00 1.54996950e+00 2.01345123e+00 0.87853922 0.86918316 873.25 1.21731124e+00 1.58900917e+00 2.00169848e+00 0.91708197 0.86461962 873.50 1.42770968e+00 1.41256923e+00 2.00840901e+00 0.78006759 0.86243455 873.75 1.45799196e+00 1.34963036e+00 1.98676689e+00 0.74682181 0.85482856 874.00 1.43923054e+00 1.54898223e+00 2.11441020e+00 0.82210987 0.82268567 874.25 1.78409506e+00 1.56383172e+00 2.37245966e+00 0.71970187 0.82303363 874.50 1.92642652e+00 1.43024517e+00 2.39931666e+00 0.63864147 0.77897346 874.75 2.03547697e+00 1.35182713e+00 2.44348176e+00 0.58624637 0.76029567 875.00 2.38036502e+00 1.26435206e+00 2.69531515e+00 0.48826290 0.81221464 875.25 2.33234896e+00 1.07412524e+00 2.56779997e+00 0.43157912 0.80474925 875.50 2.59461587e+00 9.94540255e-01 2.77869427e+00 0.36603551 0.79700518 875.75 2.92426974e+00 6.96649905e-01 3.00610622e+00 0.23387107 0.69348836 876.00 2.77537916e+00 6.37784465e-01 2.84771812e+00 0.22587923 0.60565711 876.25 3.14923265e+00 5.05648676e-01 3.18956845e+00 0.15920368 0.60264037 876.50 3.18410130e+00 2.64413670e-01 3.19506114e+00 0.08285175 0.58433567 876.75 3.13385025e+00 -1.09718798e-02 3.13386946e+00 -0.00350107 0.58355737 877.00 2.94214143e+00 -8.53029410e-01 3.06330792e+00 -0.28219735 0.50739548 877.25 2.73810996e+00 -1.13254209e+00 2.96308922e+00 -0.39219391 0.45645101 877.50 2.63460782e+00 -1.79282534e+00 3.18675087e+00 -0.59751192 0.44655902 877.75 2.66629600e+00 -2.45565136e+00 3.62482523e+00 -0.74429544 0.45883266 878.00 2.13911137e+00 -3.08956947e+00 3.75782344e+00 -0.96521257 0.48973639 878.25 -3.40490173e-01 -3.62168330e+00 3.63765357e+00 -1.66453514 0.46697433 878.50 -4.75463150e-01 -3.73246309e+00 3.76262487e+00 -1.69749982 0.55428456 878.75 -3.89472145e-01 -2.74271930e+00 2.77023423e+00 -1.71185543 0.40525684 879.00 -6.77691266e-01 -1.80671612e+00 1.92963431e+00 -1.92965081 0.28366008 879.25 -9.66757902e-01 -1.48865825e+00 1.77502795e+00 -2.14676062 0.30562620 879.50 -8.65559522e-01 -1.29742698e+00 1.55965062e+00 -2.15912340 0.32374160 879.75 -3.45243375e-01 -1.67289808e+00 1.70815134e+00 -1.77431356 0.44515406 880.00 -1.78074538e-01 -1.72044002e+00 1.72963129e+00 -1.67393428 0.43152982 880.25 -1.85199927e-01 -1.50343258e+00 1.51479653e+00 -1.69336358 0.45946202 880.50 -1.49667044e-01 -1.64588709e+00 1.65267799e+00 -1.66148089 0.53326167 880.75 -1.59768434e-01 -1.79678525e+00 1.80387449e+00 -1.65948213 0.65262690 881.00 -2.19868954e-01 -1.53411455e+00 1.54979025e+00 -1.71314673 0.56715400 881.25 9.00089540e-02 -1.73199801e+00 1.73433524e+00 -1.51887476 0.54093978 881.50 3.11326259e-01 -1.84772180e+00 1.87376623e+00 -1.40387222 0.54525152 881.75 2.27479538e-01 -1.71512453e+00 1.73014424e+00 -1.43893443 0.46144655 882.00 3.20072513e-01 -1.32658907e+00 1.36465563e+00 -1.33404632 0.31466225 882.25 5.90604366e-02 -1.00403422e+00 1.00576978e+00 -1.51204090 0.20044650 882.50 1.02212711e-01 -5.65760080e-01 5.74919043e-01 -1.39205990 0.05700512 882.75 -8.54012894e-01 -3.66519896e-02 8.54799036e-01 -3.09870160 0.05628803 883.00 -1.16015330e+00 2.78672649e-01 1.19315302e+00 2.90585546 0.15390979 883.25 -9.98123502e-01 7.60983397e-01 1.25512798e+00 2.49019377 0.30497687 883.50 -1.25007404e+00 9.23959319e-01 1.55447288e+00 2.50508881 0.49728338 883.75 -1.38054016e+00 1.07088411e+00 1.74719315e+00 2.48184581 0.66737965 884.00 -1.47238767e+00 1.10416887e+00 1.84041146e+00 2.49814453 0.72451551 884.25 -1.49066094e+00 9.61246625e-01 1.77371506e+00 2.56884922 0.80760244 884.50 -1.54856163e+00 8.13463097e-01 1.74921849e+00 2.65790864 0.83312472 884.75 -1.40943561e+00 6.74697467e-01 1.56260212e+00 2.69512941 0.77439176 885.00 -1.24851306e+00 6.53379556e-01 1.40914502e+00 2.65945872 0.75603781 885.25 -1.19421067e+00 6.58694028e-01 1.36382438e+00 2.63754278 0.70662254 885.50 -1.16435343e+00 6.72682400e-01 1.34470090e+00 2.61770881 0.70209605 885.75 -1.31018698e+00 8.29859641e-01 1.55088908e+00 2.57698265 0.80874123 886.00 -1.22017570e+00 9.27832203e-01 1.53287356e+00 2.49146320 0.81045743 886.25 -1.04141472e+00 7.58367527e-01 1.28828022e+00 2.51218430 0.80349601 886.50 -8.70485192e-01 7.80775498e-01 1.16933949e+00 2.41046914 0.82816936 886.75 -8.80376932e-01 7.61152583e-01 1.16379414e+00 2.42869722 0.89269314 887.00 -8.36909168e-01 7.83788332e-01 1.14662161e+00 2.38895929 0.90623356 887.25 -8.19018994e-01 8.00865167e-01 1.14550300e+00 2.36740089 0.91696830 887.50 -7.94839925e-01 8.11463233e-01 1.13588868e+00 2.34584606 0.88856414 887.75 -7.43474069e-01 7.58029768e-01 1.06177343e+00 2.34650071 0.90514995 888.00 -6.97163445e-01 6.93882286e-01 9.83620606e-01 2.35855326 0.91547196 888.25 -7.09139644e-01 6.82416336e-01 9.84160094e-01 2.37539603 0.93925822 888.50 -7.13850708e-01 6.90399487e-01 9.93093291e-01 2.37289311 0.91330531 888.75 -6.55171152e-01 7.06290726e-01 9.63377303e-01 2.31866456 0.91419789 889.00 -5.97193288e-01 7.41888323e-01 9.52385482e-01 2.24855669 0.91249443 889.25 -5.37163167e-01 7.42809464e-01 9.16684334e-01 2.19689128 0.90684808 889.50 -3.57402527e-01 7.50606385e-01 8.31352218e-01 2.01518395 0.91229857 889.75 -3.22245916e-01 7.00542045e-01 7.71104135e-01 2.00193103 0.91515075 890.00 -2.94695334e-01 5.82408646e-01 6.52721358e-01 2.03922770 0.89711356 890.25 -3.15579900e-01 5.35083978e-01 6.21212957e-01 2.10366455 0.89231848 890.50 -3.06857080e-01 4.00679982e-01 5.04683777e-01 2.22435871 0.79930229 890.75 -2.80378570e-01 3.33234255e-01 4.35496511e-01 2.27026810 0.76292380 891.00 -2.98147445e-01 1.95307238e-01 3.56422244e-01 2.56166203 0.68836136 891.25 -3.42752778e-01 1.33280690e-01 3.67754278e-01 2.77073192 0.72264840 891.50 -4.24470611e-01 8.31133054e-02 4.32531064e-01 2.94823435 0.80281101 891.75 -4.74436088e-01 4.38992243e-02 4.76462741e-01 3.04932610 0.81904369 892.00 -5.62316193e-01 8.58551511e-03 5.62381731e-01 3.12632571 0.83199705 892.25 -6.38433885e-01 9.48051335e-03 6.38504272e-01 3.12674410 0.87257673 892.50 -7.47971814e-01 3.00069984e-02 7.48573480e-01 3.10149634 0.91280967 892.75 -7.48656714e-01 6.77454756e-02 7.51715587e-01 3.05134906 0.89827459 893.00 -8.05522066e-01 9.74304620e-02 8.11392934e-01 3.02122418 0.91371821 893.25 -8.72419249e-01 1.24360360e-01 8.81238245e-01 2.99999999 0.92793630 893.50 -9.11271213e-01 1.47739472e-01 9.23169635e-01 2.98086652 0.93599440 893.75 -8.99385978e-01 1.76756347e-01 9.16590391e-01 2.94753583 0.94276223 894.00 -9.04660870e-01 2.04532483e-01 9.27493842e-01 2.91924339 0.96052588 894.25 -9.19328758e-01 2.30426188e-01 9.47766634e-01 2.89600597 0.96137942 894.50 -9.44991400e-01 2.81833656e-01 9.86123195e-01 2.85175188 0.97341205 894.75 -9.20756519e-01 2.76164188e-01 9.61279994e-01 2.85019840 0.96143555 895.00 -9.06639267e-01 3.03201700e-01 9.55994786e-01 2.81886105 0.95038822 895.25 -9.53638325e-01 2.47490356e-01 9.85229685e-01 2.88767215 0.94736191 895.50 -9.65467474e-01 2.12790349e-01 9.88639052e-01 2.92465954 0.95844176 895.75 -1.01835302e+00 2.16544429e-01 1.04112168e+00 2.93207158 0.95847438 896.00 -1.07501837e+00 2.46869582e-01 1.10300004e+00 2.91586412 0.96644080 896.25 -1.09740217e+00 2.78115485e-01 1.13209529e+00 2.89338764 0.97054748 896.50 -1.11437942e+00 3.10229560e-01 1.15675575e+00 2.87007963 0.97691387 896.75 -1.10696151e+00 3.59994405e-01 1.16402739e+00 2.82717128 0.97327210 897.00 -1.10804838e+00 3.94888460e-01 1.17631123e+00 2.79924369 0.96943373 897.25 -1.16221530e+00 4.01664406e-01 1.22966609e+00 2.80884087 0.97683172 897.50 -1.20154565e+00 4.19825797e-01 1.27277871e+00 2.80544819 0.98657515 897.75 -1.22842923e+00 4.65091054e-01 1.31352505e+00 2.77966404 0.97474547 898.00 -1.22229686e+00 5.07722921e-01 1.32355286e+00 2.74789470 0.97518120 898.25 -1.18543504e+00 4.73184959e-01 1.27638562e+00 2.76180574 0.96106408 898.50 -1.21165572e+00 4.74629846e-01 1.30130053e+00 2.76824448 0.96913678 898.75 -1.24271030e+00 4.75104889e-01 1.33043359e+00 2.77642564 0.97127443 899.00 -1.27303225e+00 4.62279699e-01 1.35436835e+00 2.79326652 0.97125057 899.25 -1.40494481e+00 4.69199007e-01 1.48122166e+00 2.81927588 0.95356743 899.50 -1.45476338e+00 4.87884325e-01 1.53439486e+00 2.81801002 0.95721984 899.75 -1.44583416e+00 6.14207116e-01 1.57088726e+00 2.73988160 0.92502816 900.00 -1.56131652e+00 6.84904110e-01 1.70493487e+00 2.72819985 0.91848513 900.25 -1.83063840e+00 7.25024734e-01 1.96898396e+00 2.76449589 0.94552285 900.50 -1.79886493e+00 7.83157637e-01 1.96195079e+00 2.73097804 0.93844604 900.75 -1.77305177e+00 1.04179661e+00 2.05646608e+00 2.61036107 0.90883983 901.00 -1.78004897e+00 1.14074445e+00 2.11420723e+00 2.57167666 0.92266641 901.25 -1.69387585e+00 1.43809580e+00 2.22201145e+00 2.43768107 0.90128941 901.50 -1.67605086e+00 1.51676348e+00 2.26046852e+00 2.40604249 0.90916055 901.75 -1.49627455e+00 1.68744710e+00 2.25528607e+00 2.29621962 0.93459856 902.00 -1.37085510e+00 1.70003690e+00 2.18388855e+00 2.24940806 0.93640403 902.25 -1.35097752e+00 1.62635251e+00 2.11427593e+00 2.26396630 0.94515735 902.50 -1.25616086e+00 1.52388401e+00 1.97488293e+00 2.26018881 0.93842478 902.75 -1.18167127e+00 1.54601953e+00 1.94589912e+00 2.22340662 0.92158324 903.00 -1.09326824e+00 1.63809416e+00 1.96941309e+00 2.15930822 0.92541827 903.25 -9.61937696e-01 1.73767605e+00 1.98616268e+00 2.07638174 0.94983249 903.50 -9.46873479e-01 1.76045641e+00 1.99894376e+00 2.06426878 0.94816003 903.75 -8.42335328e-01 1.67578578e+00 1.87557639e+00 2.03656245 0.94654521 904.00 -8.30797120e-01 1.68067732e+00 1.87480668e+00 2.02989187 0.96305500 904.25 -7.50506793e-01 1.73623750e+00 1.89150234e+00 1.97880053 0.96234388 904.50 -7.19724469e-01 1.73607071e+00 1.87934692e+00 1.96380041 0.96496417 904.75 -6.69909745e-01 1.70911673e+00 1.83571759e+00 1.94435472 0.96695934 905.00 -6.20264855e-01 1.69250306e+00 1.80258012e+00 1.92207466 0.96412577 905.25 -5.63787877e-01 1.68735850e+00 1.77905466e+00 1.89325879 0.95891574 905.50 -5.84480453e-01 1.66377190e+00 1.76344955e+00 1.90862741 0.97398712 905.75 -6.16188504e-01 1.58630134e+00 1.70177561e+00 1.94130071 0.98603856 906.00 -6.55887003e-01 1.58685181e+00 1.71705750e+00 1.96273753 0.98537605 906.25 -7.23344504e-01 1.62359790e+00 1.77744125e+00 1.98991801 0.98035792 906.50 -7.19605996e-01 1.75103207e+00 1.89313130e+00 1.96071604 0.97544233 906.75 -6.79196048e-01 1.89590964e+00 2.01389688e+00 1.91479547 0.97882210 907.00 -5.81954203e-01 1.91837883e+00 2.00470647e+00 1.86533035 0.98090729 907.25 -5.66781927e-01 1.91318721e+00 1.99537642e+00 1.85880932 0.98477471 907.50 -4.83505758e-01 1.96782803e+00 2.02635757e+00 1.81172884 0.97538349 907.75 -3.50489333e-01 1.99439733e+00 2.02496012e+00 1.74475697 0.97563041 908.00 -3.28583345e-01 2.02729555e+00 2.05375126e+00 1.73147866 0.97303979 908.25 -2.70356357e-01 1.99111775e+00 2.00938857e+00 1.70575219 0.96671229 908.50 -1.40333337e-01 2.00287921e+00 2.00778948e+00 1.64074781 0.94641291 908.75 -2.60749818e-02 2.03115265e+00 2.03132001e+00 1.58363315 0.94802342 909.00 6.85426740e-02 1.99419946e+00 1.99537706e+00 1.53643883 0.87610734 909.25 1.33962519e-01 1.89778774e+00 1.90250999e+00 1.50032444 0.81839560 909.50 5.45602496e-01 1.66395897e+00 1.75112579e+00 1.25394895 0.79643882 909.75 6.13564457e-01 1.49150164e+00 1.61277354e+00 1.18052370 0.79263554 910.00 5.52387547e-01 1.34254076e+00 1.45173955e+00 1.18045894 0.83944437 910.25 6.14458203e-01 1.32636336e+00 1.46177928e+00 1.13696585 0.88411235 910.50 6.75147844e-01 1.22325344e+00 1.39720205e+00 1.06647408 0.89410092 910.75 7.37212215e-01 1.12349245e+00 1.34376975e+00 0.99008956 0.89959911 911.00 7.80333035e-01 1.06980040e+00 1.32415729e+00 0.94059751 0.91538785 911.25 7.62578127e-01 1.04808044e+00 1.29614737e+00 0.94178926 0.92544677 911.50 8.01636734e-01 9.72270059e-01 1.26013115e+00 0.88129382 0.93503709 911.75 7.55288424e-01 8.91236329e-01 1.16823063e+00 0.86777787 0.94075114 912.00 7.47089485e-01 7.27624366e-01 1.04287100e+00 0.77219968 0.94821801 912.25 6.76834956e-01 6.90966722e-01 9.67233462e-01 0.79572953 0.92995047 912.50 6.11688016e-01 5.76917561e-01 8.40830602e-01 0.75615336 0.88939977 912.75 5.91958818e-01 5.47929403e-01 8.06623749e-01 0.74679127 0.89628265 913.00 4.93108938e-01 5.08774178e-01 7.08524939e-01 0.80103269 0.86950510 913.25 4.40319047e-01 4.96969082e-01 6.63972237e-01 0.84576509 0.83086494 913.50 3.24294665e-01 4.80264410e-01 5.79500590e-01 0.97688048 0.76472096 913.75 3.49523071e-01 4.25215660e-01 5.50431408e-01 0.88278986 0.69234498 914.00 2.65593073e-01 4.54240419e-01 5.26188216e-01 1.04170493 0.60412270 914.25 2.06989614e-01 3.59263111e-01 4.14625956e-01 1.04809786 0.41400041 914.50 1.82911663e-01 2.14168056e-01 2.81646290e-01 0.86395185 0.23432618 914.75 -1.77587300e-03 2.58942091e-01 2.58948180e-01 1.57765441 0.23874966 915.00 -7.01550418e-02 3.36102076e-01 3.43345796e-01 1.77657315 0.32207740 915.25 2.53538220e-03 2.72028783e-01 2.72040598e-01 1.56147632 0.17347684 915.50 -2.98968145e-02 2.42234859e-01 2.44072830e-01 1.69359609 0.17901962 915.75 1.73233345e-02 2.91692291e-01 2.92206247e-01 1.51147693 0.31942584 916.00 -3.49866607e-02 2.58350406e-01 2.60708648e-01 1.70540074 0.30059301 916.25 -2.42169540e-02 1.93315470e-01 1.94826414e-01 1.69541881 0.19599140 916.50 -1.45354063e-02 1.59663886e-01 1.60324155e-01 1.66158360 0.21838485 916.75 -7.91269181e-03 1.63983492e-01 1.64174286e-01 1.61901191 0.27626388 917.00 1.44145766e-02 1.91847607e-01 1.92388368e-01 1.49580168 0.55096731 917.25 8.46227793e-02 1.74128569e-01 1.93602100e-01 1.11842853 0.58482882 917.50 1.37071818e-01 1.60781777e-01 2.11280532e-01 0.86483339 0.76384854 917.75 1.71914303e-01 1.73122070e-01 2.43979054e-01 0.78889855 0.79212954 918.00 2.23007443e-01 1.90942599e-01 2.93583712e-01 0.70809187 0.85314536 918.25 2.83192304e-01 1.86365445e-01 3.39013215e-01 0.58203996 0.86898901 918.50 3.44177440e-01 1.78727094e-01 3.87816302e-01 0.47895840 0.90632215 918.75 3.93135536e-01 1.48429490e-01 4.20222397e-01 0.36100701 0.91993049 919.00 4.07925609e-01 1.14191121e-01 4.23607029e-01 0.27294494 0.93145734 919.25 4.26645794e-01 5.45803079e-02 4.30122824e-01 0.12723774 0.91802714 919.50 4.12153394e-01 4.14044789e-02 4.14227898e-01 0.10012299 0.91679721 919.75 3.98855525e-01 1.37367000e-02 3.99092003e-01 0.03442668 0.92439639 920.00 3.86565680e-01 1.19773236e-02 3.86751187e-01 0.03097402 0.93387651 920.25 3.79132520e-01 -6.19572237e-03 3.79183141e-01 -0.01634038 0.92447471 920.50 3.88116192e-01 -1.67232898e-02 3.88476314e-01 -0.04306172 0.93895223 920.75 3.76065093e-01 -2.94519382e-02 3.77216610e-01 -0.07815654 0.92234734 921.00 3.75453383e-01 -5.65915875e-02 3.79694417e-01 -0.14960250 0.92711604 921.25 3.55489538e-01 -1.13289065e-01 3.73104843e-01 -0.30850934 0.90410343 921.50 3.45716799e-01 -1.32700096e-01 3.70309898e-01 -0.36649860 0.88813801 921.75 3.13872807e-01 -1.97387454e-01 3.70780186e-01 -0.56138256 0.87285699 922.00 2.86308921e-01 -2.35092344e-01 3.70460805e-01 -0.68748356 0.88414444 922.25 2.40102590e-01 -2.66730583e-01 3.58879447e-01 -0.83788789 0.86655414 922.50 1.85690595e-01 -2.69750104e-01 3.27484527e-01 -0.96791162 0.80131316 922.75 9.18548209e-02 -2.64876901e-01 2.80351709e-01 -1.23699025 0.78835191 923.00 6.01229474e-02 -2.53053528e-01 2.60097783e-01 -1.33753148 0.74956563 923.25 1.43599495e-02 -2.01787940e-01 2.02298248e-01 -1.49975253 0.65260727 923.50 -2.78694587e-02 -1.96413264e-01 1.98380636e-01 -1.71174735 0.65911080 923.75 -6.96717488e-02 -1.68207492e-01 1.82065683e-01 -1.96348488 0.71215221 924.00 -7.70559026e-02 -1.30718728e-01 1.51739903e-01 -2.10344364 0.55484925 924.25 -8.86718269e-02 -5.39963324e-02 1.03818576e-01 -2.59462135 0.34556261 924.50 -8.12644476e-02 -4.34465272e-02 9.21493959e-02 -2.65062525 0.31285910 924.75 -6.53126002e-02 -7.76686034e-03 6.57727897e-02 -3.02323025 0.15360431 925.00 -4.44418452e-02 2.83965970e-03 4.45324743e-02 3.07778332 0.07773145 925.25 -3.94091042e-02 1.16369244e-02 4.10913069e-02 2.85446698 0.05460652 925.50 -2.06037220e-02 -1.44023173e-02 2.51384189e-02 -2.53152786 0.02494785 925.75 -3.70759731e-02 -2.06400634e-02 4.24339487e-02 -2.63362274 0.09128566 926.00 -7.29798038e-02 -1.34279369e-02 7.42048600e-02 -2.95963257 0.23983573 926.25 -8.22623088e-02 -1.70142033e-03 8.22799021e-02 -3.12091274 0.34769619 926.50 -8.36864400e-02 8.25635789e-03 8.40927327e-02 3.04325264 0.33482778 926.75 -1.05855089e-01 4.14599364e-02 1.13684767e-01 2.76829055 0.45810908 927.00 -1.07684927e-01 6.06893140e-02 1.23609208e-01 2.62838145 0.55481303 927.25 -1.09673556e-01 8.04076012e-02 1.35991438e-01 2.50896048 0.69553836 927.50 -1.09756481e-01 9.56988419e-02 1.45618520e-01 2.42450989 0.67303754 927.75 -1.10842713e-01 1.01446932e-01 1.50258401e-01 2.40042487 0.69148455 928.00 -1.13537564e-01 1.98646907e-01 2.28804222e-01 2.09003748 0.71481962 928.25 -1.25362474e-01 2.67025756e-01 2.94988990e-01 2.00972883 0.80954078 928.50 -7.60657224e-02 3.05210990e-01 3.14546884e-01 1.81504394 0.73400799 928.75 -2.82910903e-02 3.59366802e-01 3.60478688e-01 1.64935912 0.75118812 929.00 1.35172344e-02 4.42045223e-01 4.42251846e-01 1.54022700 0.64551106 929.25 1.56474487e-01 4.97306408e-01 5.21342429e-01 1.26595938 0.65831783 929.50 2.99949991e-01 5.05923363e-01 5.88156821e-01 1.03563128 0.63372784 929.75 4.34317801e-01 4.99956691e-01 6.62260255e-01 0.85553945 0.60254958 930.00 7.25451724e-01 2.32278328e-01 7.61730547e-01 0.30987021 0.64928395 930.25 7.99953434e-01 4.49552564e-02 8.01215621e-01 0.05613829 0.74673421 930.50 6.27218903e-01 -1.07386511e-01 6.36345359e-01 -0.16956650 0.65670080 930.75 5.91065141e-01 -1.69062622e-01 6.14768388e-01 -0.27859193 0.64023031 931.00 5.31781850e-01 -2.01267498e-01 5.68595235e-01 -0.36181600 0.72343934 931.25 5.53647305e-01 -1.73528324e-01 5.80204634e-01 -0.30372968 0.74423788 931.50 6.42763267e-01 -1.45199890e-01 6.58959502e-01 -0.22217042 0.85803172 931.75 7.38617723e-01 -1.51236331e-01 7.53942020e-01 -0.20196432 0.86731753 932.00 9.96580112e-01 -3.68124971e-01 1.06239725e+00 -0.35384171 0.85067768 932.25 9.96622249e-01 -6.12546964e-01 1.16981609e+00 -0.55110238 0.85328213 932.50 7.51107993e-01 -9.26633909e-01 1.19281751e+00 -0.88963928 0.77554503 932.75 4.76898179e-01 -1.07614175e+00 1.17707814e+00 -1.15364881 0.78308525 933.00 1.68021643e-01 -1.11154240e+00 1.12416982e+00 -1.42077131 0.81001074 933.25 5.39850932e-02 -1.02481791e+00 1.02623883e+00 -1.51816723 0.80920941 933.50 -5.06356293e-02 -8.46905082e-01 8.48417460e-01 -1.63051426 0.80316750 933.75 -1.69171397e-02 -7.39041808e-01 7.39235405e-01 -1.59368297 0.76064465 934.00 -7.08115784e-02 -5.99240310e-01 6.03409669e-01 -1.68841977 0.77398644 934.25 -8.43680040e-02 -5.59719549e-01 5.66042343e-01 -1.72040271 0.76186082 934.50 3.29251867e-02 -5.30408867e-01 5.31429801e-01 -1.50880077 0.77646424 934.75 1.13038449e-02 -6.01797207e-01 6.01903360e-01 -1.55201506 0.84601271 935.00 -1.55791807e-02 -5.94938380e-01 5.95142325e-01 -1.59697655 0.80821400 935.25 1.70223175e-03 -5.80900208e-01 5.80902703e-01 -1.56786600 0.85433198 935.50 2.40168079e-02 -5.77957249e-01 5.78456038e-01 -1.52926558 0.87279045 935.75 3.89511782e-02 -5.68915985e-01 5.70247834e-01 -1.50243740 0.83542235 936.00 9.64555827e-02 -5.78430427e-01 5.86417461e-01 -1.40556269 0.85075218 936.25 9.62208242e-02 -5.83747814e-01 5.91624846e-01 -1.40743242 0.80903171 936.50 -4.55974968e-02 -5.93352874e-01 5.95102315e-01 -1.64749277 0.77102726 936.75 -1.10129617e-01 -5.91734312e-01 6.01895363e-01 -1.75480432 0.74512325 937.00 -1.58277102e-01 -6.25932804e-01 6.45634197e-01 -1.81847054 0.74671299 937.25 -1.44949684e-01 -5.68743399e-01 5.86923730e-01 -1.82034342 0.68096357 937.50 -1.14503172e-01 -4.68520500e-01 4.82309481e-01 -1.81049097 0.69522399 937.75 -1.27998856e-01 -4.19937162e-01 4.39011306e-01 -1.86665533 0.64455394 938.00 -1.41760103e-01 -3.17742522e-01 3.47931369e-01 -1.99044208 0.59191374 938.25 -1.16160530e-01 -2.78625475e-01 3.01869880e-01 -1.96579104 0.59807363 938.50 -4.97286294e-02 -2.50138749e-01 2.55033979e-01 -1.76704180 0.65163007 938.75 -2.31511666e-02 -2.69807186e-01 2.70798623e-01 -1.65639300 0.65785411 939.00 -8.83685569e-03 -2.92365683e-01 2.92499201e-01 -1.60101248 0.62562552 939.25 -5.02318008e-02 -3.41861730e-01 3.45532454e-01 -1.71668837 0.60825954 939.50 -8.53135287e-02 -3.49388758e-01 3.59653864e-01 -1.81028930 0.67134270 939.75 -8.72267510e-02 -3.48753892e-01 3.59496569e-01 -1.81587829 0.73533805 940.00 -8.84930863e-02 -3.23510891e-01 3.35395771e-01 -1.83780444 0.78913074 940.25 -9.98981497e-02 -2.65328840e-01 2.83511964e-01 -1.93088750 0.77629292 940.50 -7.62828274e-02 -2.28939034e-01 2.41313388e-01 -1.89242822 0.67618231 940.75 -4.55785152e-02 -1.19389141e-01 1.27793458e-01 -1.93548414 0.26187950 941.00 -4.77366531e-03 -7.66860388e-02 7.68344742e-02 -1.63296558 0.11818574 941.25 1.09292011e-01 -1.12747237e-02 1.09872030e-01 -0.10279782 0.16879807 941.50 1.46486366e-01 7.95724617e-03 1.46702329e-01 0.05426739 0.19687903 941.75 2.59558471e-01 7.10482033e-02 2.69106758e-01 0.26718248 0.38555520 942.00 3.62193665e-01 9.37511189e-02 3.74130356e-01 0.25328356 0.52247841 942.25 5.32182454e-01 2.13219352e-01 5.73306773e-01 0.38106733 0.56620354 942.50 6.44658350e-01 3.17952374e-01 7.18803242e-01 0.45820140 0.60420058 942.75 7.80250982e-01 2.82457307e-01 8.29803425e-01 0.34733230 0.65017481 943.00 7.69563071e-01 3.70002133e-01 8.53890449e-01 0.44816597 0.61882110 943.25 9.31787215e-01 4.70225626e-01 1.04371431e+00 0.46736001 0.64236709 943.50 1.02768592e+00 5.29592597e-01 1.15611706e+00 0.47583258 0.68203963 943.75 1.18083575e+00 5.84333641e-01 1.31750479e+00 0.45951713 0.77097646 944.00 1.26507033e+00 5.90257533e-01 1.39599674e+00 0.43655665 0.80113598 944.25 1.34710149e+00 6.20999018e-01 1.48334831e+00 0.43195474 0.78691101 944.50 1.50448451e+00 4.83077140e-01 1.58013834e+00 0.31069271 0.73171337 944.75 1.73432070e+00 5.13221554e-01 1.80866377e+00 0.28771021 0.69308736 945.00 1.60736597e+00 4.56711037e-01 1.67099083e+00 0.27684017 0.64260367 945.25 1.29890013e+00 2.48848364e-01 1.32252299e+00 0.18929022 0.58994045 945.50 1.35802367e+00 2.18409861e-01 1.37547489e+00 0.15946366 0.59622681 945.75 1.69877248e+00 5.73255296e-01 1.79288861e+00 0.32545336 0.76482155 946.00 1.60688186e+00 6.75641084e-01 1.74314664e+00 0.39802505 0.77785618 946.25 1.54953186e+00 5.57109176e-01 1.64663888e+00 0.34514286 0.77901550 946.50 1.67248780e+00 6.62375085e-01 1.79887637e+00 0.37708949 0.85950545 946.75 1.69763015e+00 7.71271804e-01 1.86462015e+00 0.42644281 0.88267335 947.00 1.72850523e+00 7.55365529e-01 1.88634764e+00 0.41199494 0.88562874 947.25 1.87002252e+00 7.99416494e-01 2.03372834e+00 0.40397806 0.87416461 947.50 1.81315810e+00 8.11714249e-01 1.98656042e+00 0.42092277 0.88221837 947.75 1.75373765e+00 8.13451773e-01 1.93320964e+00 0.43430259 0.89396505 948.00 1.67344220e+00 8.21449699e-01 1.86418572e+00 0.45632040 0.88438936 948.25 1.64312426e+00 8.37341207e-01 1.84417939e+00 0.47130054 0.87570435 948.50 1.64914192e+00 9.03344280e-01 1.88034570e+00 0.50112662 0.91046901 948.75 1.65868761e+00 9.26196998e-01 1.89975932e+00 0.50926295 0.90618491 949.00 1.65182479e+00 8.58441851e-01 1.86157126e+00 0.47927764 0.87748138 949.25 1.58912682e+00 8.67378598e-01 1.81043356e+00 0.49962901 0.88015987 949.50 1.38320504e+00 1.01484128e+00 1.71556376e+00 0.63297959 0.85277983 949.75 1.40539508e+00 1.09402117e+00 1.78101590e+00 0.66145806 0.86386119 950.00 1.43534377e+00 9.16805975e-01 1.70315734e+00 0.56841609 0.83541144 950.25 1.36372398e+00 7.48411009e-01 1.55559061e+00 0.50192104 0.79956279 950.50 1.25522282e+00 6.97924928e-01 1.43620456e+00 0.50745087 0.79763298 950.75 1.18957176e+00 6.94080321e-01 1.37725396e+00 0.52817697 0.80845355 951.00 1.27145131e+00 6.86013043e-01 1.44471531e+00 0.49478570 0.79901169 951.25 1.18461228e+00 6.78832667e-01 1.36532782e+00 0.52036159 0.73819814 951.50 1.07648144e+00 6.66616166e-01 1.26617116e+00 0.55445718 0.80172628 951.75 9.47076615e-01 7.50933522e-01 1.20865846e+00 0.67039437 0.80325779 952.00 9.11157306e-01 7.43920464e-01 1.17627603e+00 0.68469526 0.76796225 952.25 8.86710733e-01 7.48202247e-01 1.16019935e+00 0.70088080 0.74731957 952.50 7.13577640e-01 9.39851694e-01 1.18004841e+00 0.92140467 0.77114987 952.75 6.30241473e-01 8.86891755e-01 1.08801714e+00 0.95297951 0.81189066 953.00 6.73176126e-01 8.98621003e-01 1.12280266e+00 0.92785783 0.84832383 953.25 7.20408408e-01 9.24134955e-01 1.17175667e+00 0.90865055 0.82348332 953.50 7.56259508e-01 7.50036822e-01 1.06512144e+00 0.78126707 0.78130950 953.75 7.04572397e-01 7.66250751e-01 1.04094307e+00 0.82730819 0.74688613 954.00 5.44086837e-01 6.53301899e-01 8.50196364e-01 0.87635751 0.60304112 954.25 4.48295972e-01 6.67521719e-01 8.04086142e-01 0.97939810 0.53951803 954.50 3.79104337e-01 5.98397722e-01 7.08378382e-01 1.00608488 0.43777585 954.75 2.27465840e-01 5.41603213e-01 5.87430633e-01 1.17318012 0.28131468 955.00 -8.75298822e-02 7.44109984e-01 7.49240381e-01 1.68788854 0.42056853 955.25 -1.52596112e-01 8.56566420e-01 8.70052645e-01 1.74709539 0.45643421 955.50 -2.86661027e-01 1.15473941e+00 1.18978891e+00 1.81412478 0.67493691 955.75 -2.55781858e-01 1.37106041e+00 1.39471538e+00 1.75523381 0.76548222 956.00 -2.63972933e-01 1.52598329e+00 1.54864674e+00 1.74208666 0.76565242 956.25 -1.60214063e-01 1.58220796e+00 1.59029889e+00 1.67171215 0.80132130 956.50 -2.33391529e-01 1.59848105e+00 1.61542975e+00 1.71578016 0.81565196 956.75 -2.57343012e-01 1.65499900e+00 1.67488719e+00 1.72505535 0.81497842 957.00 -2.00407965e-01 1.67124609e+00 1.68321919e+00 1.69014175 0.70945768 957.25 -2.44594553e-01 1.62953225e+00 1.64778695e+00 1.71978513 0.67234598 957.50 -3.48017197e-01 1.92839624e+00 1.95954791e+00 1.74934424 0.70371640 957.75 -1.64732906e-01 1.95678936e+00 1.96371116e+00 1.65478359 0.72685215 958.00 -3.42784474e-02 2.05638827e+00 2.05667394e+00 1.58746403 0.80891220 958.25 5.52425465e-03 2.10922551e+00 2.10923274e+00 1.56817724 0.85255289 958.50 -7.06283845e-02 2.09404943e+00 2.09524017e+00 1.60451168 0.87665693 958.75 2.23111275e-02 2.12583410e+00 2.12595117e+00 1.56030148 0.83907504 959.00 1.12275861e-02 2.13220885e+00 2.13223841e+00 1.56553067 0.83218578 959.25 1.37359941e-01 1.91365361e+00 1.91857705e+00 1.49914033 0.79814180 959.50 1.87106190e-01 1.83532865e+00 1.84484145e+00 1.46920036 0.83970213 959.75 9.60764399e-02 1.68236271e+00 1.68510385e+00 1.51375025 0.82146547 960.00 1.58800875e-01 1.55668498e+00 1.56476383e+00 1.46913579 0.79994914 960.25 8.39004455e-02 1.46194354e+00 1.46434907e+00 1.51346955 0.74065850 960.50 -9.38553383e-02 1.40289185e+00 1.40602787e+00 1.63759812 0.78189519 960.75 -2.48616857e-01 1.30958922e+00 1.33297947e+00 1.75840712 0.76201758 961.00 -2.99490419e-01 1.24333175e+00 1.27889341e+00 1.80717068 0.74603009 961.25 -3.54452730e-01 1.05405471e+00 1.11205578e+00 1.89519245 0.69238404 961.50 -4.60851029e-01 9.91520089e-01 1.09338729e+00 2.00588332 0.67730680 961.75 -5.87722221e-01 1.05557889e+00 1.20816564e+00 2.07882784 0.64678844 962.00 -5.72499886e-01 1.02154181e+00 1.17102681e+00 2.08160985 0.62415905 962.25 -7.47564831e-01 1.03152671e+00 1.27393114e+00 2.19791892 0.60247528 962.50 -8.93629400e-01 9.99939816e-01 1.34106418e+00 2.30011049 0.57835398 962.75 -7.01373055e-01 7.76054263e-01 1.04603269e+00 2.30568933 0.34878535 963.00 -8.75248686e-01 9.20066962e-01 1.26987538e+00 2.33123567 0.41151598 963.25 -8.68259699e-01 9.43642592e-01 1.28231675e+00 2.31461419 0.45315174 963.50 -7.94352827e-01 7.95088676e-01 1.12390499e+00 2.35573153 0.36537306 963.75 -4.63392755e-01 6.31818298e-01 7.83535071e-01 2.20360623 0.19229637 964.00 -4.36036783e-01 6.98433698e-01 8.23369726e-01 2.12889688 0.25729676 964.25 -4.91608979e-01 9.81378120e-01 1.09762580e+00 2.03519355 0.31975211 964.50 -6.15603115e-01 1.03342294e+00 1.20288410e+00 2.10804312 0.37240295 964.75 -6.10376968e-01 1.03084086e+00 1.19799538e+00 2.10539831 0.43263948 965.00 -4.51075417e-01 8.83267564e-01 9.91781539e-01 2.04295887 0.39243811 965.25 -3.83473725e-01 8.43415642e-01 9.26499888e-01 1.99752501 0.47677866 965.50 -2.52159061e-01 9.39679021e-01 9.72923868e-01 1.83296586 0.54943908 965.75 -8.57995402e-02 1.01051258e+00 1.01414853e+00 1.65550012 0.55917547 966.00 -4.24165584e-03 9.43512020e-01 9.43521554e-01 1.57529190 0.50990296 966.25 -1.50773332e-01 7.31593235e-01 7.46968044e-01 1.77403980 0.52264515 966.50 -2.27255477e-01 6.25454681e-01 6.65461201e-01 1.91930947 0.41912585 966.75 -6.28711292e-02 5.50017074e-01 5.53598736e-01 1.68460993 0.38313371 967.00 -2.03070429e-02 5.43943294e-01 5.44322223e-01 1.60811201 0.37324819 967.25 3.57803140e-02 4.48885381e-01 4.50309134e-01 1.49125526 0.34870255 967.50 3.94531654e-02 4.22637092e-01 4.24474574e-01 1.47771609 0.30422496 967.75 5.61208029e-02 3.81889559e-01 3.85991165e-01 1.42488513 0.28772706 968.00 9.64129824e-02 3.46664955e-01 3.59822253e-01 1.29953575 0.23546699 968.25 1.90579917e-01 2.41704240e-01 3.07801307e-01 0.90311691 0.23112971 968.50 2.35334490e-01 1.51091182e-01 2.79662059e-01 0.57075012 0.14582093 968.75 2.59171349e-01 9.28529862e-02 2.75302497e-01 0.34402208 0.13857794 969.00 1.65927527e-01 6.38694388e-02 1.77795527e-01 0.36744240 0.07104294 969.25 1.53855502e-01 9.99740214e-02 1.83483842e-01 0.57622874 0.09380001 969.50 1.72235083e-01 8.12358480e-02 1.90431580e-01 0.44071705 0.08440228 969.75 1.87177262e-01 1.13333815e-01 2.18814719e-01 0.54444592 0.07891419 970.00 1.54902783e-01 8.46888559e-02 1.76541991e-01 0.50032351 0.04011215 970.25 1.10576445e-01 -3.41235601e-02 1.15721941e-01 -0.29932518 0.01373561 970.50 1.94227682e-02 -4.25427701e-01 4.25870841e-01 -1.52517332 0.11844519 970.75 5.07980700e-02 -9.20195571e-01 9.21596622e-01 -1.51564874 0.31105789 971.00 -2.75771451e-01 -8.56454883e-01 8.99758223e-01 -1.88230501 0.27922505 971.25 -5.70948386e-01 -6.91304170e-01 8.96595513e-01 -2.26113188 0.26000425 971.50 -1.08637082e+00 -1.15242014e+00 1.58375305e+00 -2.32670082 0.47342443 971.75 -1.45295552e+00 -1.67702019e+00 2.21889082e+00 -2.28472969 0.68692695 972.00 -1.66552903e+00 -1.28967293e+00 2.10647649e+00 -2.48269987 0.73928663 972.25 -1.69644352e+00 -1.17674616e+00 2.06461913e+00 -2.53513793 0.73673679 972.50 -1.78990322e+00 -1.29642654e+00 2.21008490e+00 -2.51474358 0.64116618 972.75 -1.96684709e+00 -1.13933016e+00 2.27300697e+00 -2.61655732 0.57675338 973.00 -1.87188909e+00 -7.37068093e-01 2.01177487e+00 -2.76648035 0.44939322 973.25 -1.61501189e+00 -7.56509107e-01 1.78341510e+00 -2.70352402 0.30709488 973.50 -1.48608067e+00 -9.47813944e-01 1.76260802e+00 -2.57384572 0.37755379 973.75 -1.68268216e+00 -1.14601436e+00 2.03587037e+00 -2.54368873 0.39125210 974.00 -1.50918535e+00 -8.26582106e-01 1.72072032e+00 -2.64051634 0.28276344 974.25 -1.04376748e+00 -5.53009218e-01 1.18121537e+00 -2.65437436 0.17150368 974.50 -4.80133245e-01 -9.92794863e-01 1.10280079e+00 -2.02125248 0.06073844 974.75 -5.47621630e-01 -1.18910771e+00 1.30914728e+00 -2.00237371 0.06440506 975.00 -9.15174193e-01 -4.43944519e-01 1.01716790e+00 -2.68994167 0.02956280 975.25 -7.03853363e-01 -6.83415445e-01 9.81053631e-01 -2.37092591 0.02823076 975.50 -6.78935941e-01 1.68699824e-02 6.79145499e-01 3.11675009 0.02015516 975.75 -1.01306110e+00 9.10697752e-01 1.36222729e+00 2.40935443 0.07665346 976.00 -1.30791394e+00 5.78747558e-01 1.43024040e+00 2.72499600 0.07492917 976.25 -1.04799543e+00 2.39225641e-01 1.07495271e+00 2.91716822 0.03751524 976.50 -2.64645432e-01 6.93798292e-02 2.73588680e-01 2.88520108 0.00195850 976.75 2.87047144e-01 1.11171044e+00 1.14817079e+00 1.31811207 0.04049637 977.00 1.39733669e-01 1.93704511e+00 1.94207860e+00 1.49878353 0.13030733 977.25 -1.04050970e+00 1.49306773e+00 1.81986584e+00 2.17943457 0.13410653 977.50 -1.66804226e+00 1.23915208e+00 2.07794679e+00 2.50266516 0.21581185 977.75 -1.51485785e+00 1.06704400e+00 1.85293745e+00 2.52792942 0.20445259 978.00 -1.95750768e+00 7.17074209e-01 2.08471383e+00 2.79045348 0.33987871 978.25 -2.13784425e+00 1.37330995e-01 2.14225064e+00 3.07744272 0.37336384 978.50 -2.08081728e+00 -3.18129977e-01 2.10499578e+00 -2.98988041 0.41014635 978.75 -1.50309868e+00 2.71808885e-02 1.50334442e+00 3.12351139 0.30789359 979.00 -1.12132410e+00 2.28823335e-01 1.14443342e+00 2.94029123 0.25164072 979.25 -8.96308754e-01 4.21206165e-01 9.90345402e-01 2.70228564 0.17668131 979.50 -9.76336630e-01 4.03579474e-01 1.05646089e+00 2.74962151 0.14096688 979.75 -8.46524649e-01 4.31906857e-01 9.50340736e-01 2.66980903 0.20565894 980.00 -1.09273185e+00 2.36145281e-01 1.11795684e+00 2.92876015 0.40668523 980.25 -1.00818542e+00 1.53989885e-01 1.01987780e+00 2.99002443 0.34474256 980.50 -6.73124481e-01 2.74606384e-01 7.26983654e-01 2.75424498 0.19068697 980.75 -8.70070051e-01 7.98451118e-02 8.73726007e-01 3.05008037 0.21066824 981.00 -9.16154880e-01 1.19053783e-01 9.23857980e-01 3.01236740 0.18568115 981.25 -6.27994902e-01 1.54773362e-01 6.46786201e-01 2.89995192 0.06805926 981.50 -4.36664330e-01 3.10215377e-01 5.35639167e-01 2.52390712 0.05037376 981.75 4.00961417e-01 1.97930420e-01 4.47153787e-01 0.45854633 0.02987122 982.00 1.21288698e+00 -8.13626130e-02 1.21561289e+00 -0.06698143 0.18617755 982.25 1.67185647e+00 -5.48125761e-01 1.75941636e+00 -0.31681158 0.37585985 982.50 1.80628683e+00 -6.41244506e-01 1.91673332e+00 -0.34112843 0.45905005 982.75 1.41670797e+00 -1.01564788e+00 1.74315865e+00 -0.62198306 0.43915420 983.00 1.42315214e+00 -1.05601928e+00 1.77215652e+00 -0.63837972 0.38528538 983.25 1.13976471e+00 -3.47245447e-01 1.19148772e+00 -0.29573032 0.19378585 983.50 6.65766606e-01 -2.42421197e-01 7.08528906e-01 -0.34920109 0.09592769 983.75 7.04604150e-01 -2.94032234e-01 7.63493264e-01 -0.39533176 0.08887733 984.00 8.53954283e-01 -4.94382779e-01 9.86738187e-01 -0.52478542 0.13929726 984.25 9.83043978e-01 -3.24518022e-01 1.03522336e+00 -0.31885168 0.19263898 984.50 5.38535737e-01 -4.42470481e-02 5.40350387e-01 -0.08197763 0.05440983 984.75 4.67807217e-01 -4.50478829e-02 4.69971173e-01 -0.09599983 0.06582555 985.00 2.51026989e-01 -1.93172888e-01 3.16749607e-01 -0.65588381 0.03190482 985.25 1.31430290e-01 3.57780584e-03 1.31478978e-01 0.02721536 0.00499384 985.50 3.08537547e-01 -4.55690956e-03 3.08571197e-01 -0.01476831 0.03191719 985.75 1.19260044e-01 -7.73011763e-02 1.42121180e-01 -0.57509000 0.01040827 986.00 4.51629841e-02 -2.44769569e-01 2.48901259e-01 -1.38833621 0.03048539 986.25 6.42652535e-03 -5.50826294e-01 5.50863782e-01 -1.55912979 0.15113571 986.50 6.97111653e-02 -7.19281011e-01 7.22651243e-01 -1.47418024 0.26435509 986.75 -3.13914775e-01 -7.07056079e-01 7.73608935e-01 -1.98862805 0.34466288 987.00 -3.73720080e-01 -5.99349715e-01 7.06319177e-01 -2.12834694 0.26125782 987.25 -2.93141907e-01 -5.07266528e-01 5.85876700e-01 -2.09479634 0.24255692 987.50 -3.87481242e-01 -5.16681852e-01 6.45834227e-01 -2.21426009 0.32589480 987.75 -4.21943882e-01 -5.96614671e-01 7.30743255e-01 -2.18635828 0.37539236 988.00 -3.90351085e-01 -4.50970114e-01 5.96446153e-01 -2.28426661 0.27346771 988.25 -3.55292992e-01 -4.22771355e-01 5.52239738e-01 -2.26968501 0.28636481 988.50 -4.04301669e-01 -3.45104425e-01 5.31560819e-01 -2.43502301 0.26555718 988.75 -1.89112712e-01 -1.12135068e-01 2.19858798e-01 -2.60637042 0.04421625 989.00 3.68448382e-02 5.89425027e-02 6.95108677e-02 1.01212657 0.00344562 989.25 1.26648983e-01 -1.38744031e-01 1.87855985e-01 -0.83094075 0.01787048 989.50 4.70564088e-02 -2.12696512e-01 2.17839647e-01 -1.35306612 0.01639251 989.75 3.78903612e-02 -3.01065733e-01 3.03440694e-01 -1.44560045 0.04402599 990.00 1.38326395e-01 -2.51815196e-01 2.87306604e-01 -1.06847756 0.03339106 990.25 1.80710511e-01 -3.75110863e-01 4.16370566e-01 -1.12185318 0.05306592 990.50 4.64524436e-01 -4.50653849e-01 6.47203093e-01 -0.77024317 0.12681162 990.75 3.85618081e-01 -3.91461254e-01 5.49493601e-01 -0.79291743 0.09422929 991.00 1.84509025e-01 -8.72440081e-01 8.91737223e-01 -1.36238115 0.16396277 991.25 5.24690750e-02 -8.53170798e-01 8.54782671e-01 -1.50937477 0.16608691 991.50 -1.04985843e-02 -7.17632134e-01 7.17708924e-01 -1.58542476 0.15054573 991.75 -1.47779764e-01 -9.19705329e-01 9.31502416e-01 -1.73011615 0.23608170 992.00 -2.15368674e-01 -4.96694320e-01 5.41376868e-01 -1.97993206 0.06945531 992.25 -4.18093404e-01 -4.47035974e-01 6.12081086e-01 -2.32275235 0.10827237 992.50 -1.54655655e-01 -7.08079807e-01 7.24772644e-01 -1.78583485 0.12466012 992.75 -3.96078190e-02 -8.96041164e-01 8.96916132e-01 -1.61497070 0.20949286 993.00 -4.41116612e-01 -1.26165956e+00 1.33655105e+00 -1.90714331 0.38011554 993.25 -1.61630093e-01 -1.20265782e+00 1.21347028e+00 -1.70438993 0.33450786 993.50 2.15829959e-01 -1.10456138e+00 1.12545032e+00 -1.37782889 0.27071504 993.75 6.50828605e-02 -9.33031130e-01 9.35298278e-01 -1.50115491 0.18892951 994.00 -3.03228005e-01 -9.14338595e-01 9.63307993e-01 -1.89101891 0.26213058 994.25 -3.78389130e-01 -8.70592062e-01 9.49267545e-01 -1.98079889 0.28135600 994.50 -4.30274936e-01 -6.83530787e-01 8.07682399e-01 -2.13261699 0.21628582 994.75 -4.57085238e-01 -5.24576831e-01 6.95778532e-01 -2.28755014 0.13940990 995.00 -1.13378512e-01 -6.41945356e-02 1.30290542e-01 -2.62639948 0.00428089 995.25 -1.61480305e-01 -1.73174951e-02 1.62406233e-01 -3.03475882 0.00849200 995.50 -1.85049415e-01 5.45116188e-02 1.92911385e-01 2.85511691 0.01245306 995.75 -2.57038645e-01 3.60271177e-01 4.42565460e-01 2.19049805 0.07258959 996.00 -4.60245574e-01 6.54068196e-01 7.99769463e-01 2.18397848 0.21079753 996.25 -4.82833932e-01 6.10845885e-01 7.78627832e-01 2.23967764 0.23018080 996.50 -3.56004638e-01 9.28469397e-01 9.94381579e-01 1.93693864 0.26977769 996.75 -3.77980260e-01 9.25846928e-01 1.00003081e+00 1.95839749 0.26370832 997.00 -1.41393377e-01 6.65410446e-01 6.80266969e-01 1.78017260 0.18112638 997.25 -1.45112201e-01 7.40285079e-01 7.54373614e-01 1.76436403 0.22852373 997.50 -1.66433255e-01 1.00776556e+00 1.02141640e+00 1.73446971 0.37192570 997.75 2.65049451e-04 1.06229762e+00 1.06229765e+00 1.57054682 0.41583674 998.00 3.84229072e-01 7.71242704e-01 8.61653810e-01 1.10859395 0.35972938 998.25 4.23681760e-01 7.85009607e-01 8.92046141e-01 1.07588345 0.33262819 998.50 4.13093014e-01 4.78652996e-01 6.32261441e-01 0.85878481 0.22063011 998.75 4.30697674e-01 3.89655912e-01 5.80803079e-01 0.73541048 0.27214303 999.00 2.72134766e-01 3.94500154e-01 4.79257449e-01 0.96693415 0.24128275 999.25 4.29757740e-01 3.66064249e-01 5.64530557e-01 0.70553355 0.24284022 999.50 5.46253964e-01 3.78808405e-01 6.64747472e-01 0.60632707 0.21919799 999.75 4.74426717e-01 2.57466706e-01 5.39786823e-01 0.49721372 0.16461218 1000.00 3.98926110e-01 0.00000000e+00 3.98926110e-01 0.00000000 0.15074340