========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Y Reference mono-axial accelerometer position : R3 (horizontal, on tower vessel) Quiet acquisition : SIG0038 Injection acquisition : SIG0040 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -2.26965502e-02 0.00000000e+00 2.26965502e-02 3.14159265 0.05659169 0.25 -2.04159152e-02 -1.63793466e-03 2.04815142e-02 -3.06153580 0.05228389 0.50 -7.89033995e-03 -3.23776126e-03 8.52880780e-03 -2.75220014 0.01656868 0.75 -5.95418107e-03 8.41300973e-03 1.03068426e-02 2.18669469 0.01966094 1.00 -8.51652523e-03 1.74671267e-02 1.94327486e-02 2.02445420 0.05139591 1.25 -1.08092059e-02 8.11037314e-03 1.35135889e-02 2.49788620 0.02121955 1.50 -2.89156042e-03 -2.54741757e-03 3.85362919e-03 -2.41938369 0.00105085 1.75 -2.70100789e-03 4.32332932e-03 5.09770733e-03 2.12921716 0.00199917 2.00 2.57272047e-03 1.24818434e-02 1.27442263e-02 1.36752599 0.00903230 2.25 -1.11057819e-02 4.30958445e-03 1.19126365e-02 2.77143137 0.00700929 2.50 -8.86885933e-03 -4.83975074e-03 1.01034575e-02 -2.64205555 0.00387043 2.75 -1.96744427e-02 1.15063925e-02 2.27921207e-02 2.61239512 0.01625643 3.00 -2.84704906e-02 1.60399742e-02 3.26779682e-02 2.62852778 0.02561083 3.25 -2.20330987e-02 1.70596057e-02 2.78655268e-02 2.48273773 0.01972370 3.50 -1.57979177e-02 1.10195522e-02 1.92614832e-02 2.53252503 0.00864008 3.75 -6.82390361e-04 2.93291411e-02 2.93370785e-02 1.59405876 0.01352908 4.00 -8.67138628e-03 4.05248100e-02 4.14421665e-02 1.78159469 0.02276672 4.25 -6.35466514e-03 3.77574966e-02 3.82885142e-02 1.73753579 0.02162852 4.50 -1.41976687e-03 3.65832336e-02 3.66107732e-02 1.60958608 0.01813746 4.75 4.54213425e-05 2.52957041e-02 2.52957449e-02 1.56900071 0.00730321 5.00 6.49683618e-03 3.73503480e-02 3.79111775e-02 1.39857632 0.01357999 5.25 1.09878312e-02 2.26363121e-02 2.51621752e-02 1.11889088 0.00612022 5.50 2.02764902e-02 1.99933768e-02 2.84757997e-02 0.77836788 0.00727165 5.75 -2.12507569e-02 3.48846032e-02 4.08476463e-02 2.11793336 0.01468762 6.00 -1.87894167e-02 3.88191948e-02 4.31273934e-02 2.02158154 0.01513596 6.25 -3.79475674e-03 8.45882096e-03 9.27102102e-03 1.99249816 0.00054809 6.50 -9.99671794e-03 4.82060675e-03 1.10983160e-02 2.69227081 0.00076574 6.75 -1.97514342e-02 3.63156676e-02 4.13394106e-02 2.06893021 0.01036673 7.00 -1.58866820e-02 4.53399166e-02 4.80426342e-02 1.90781911 0.01344896 7.25 9.96822630e-03 2.27725162e-02 2.48586610e-02 1.15819238 0.00361970 7.50 -1.03115618e-02 3.62694629e-02 3.77067931e-02 1.84779187 0.00739340 7.75 -3.78522031e-02 5.96252709e-02 7.06255068e-02 2.13643669 0.02089684 8.00 -2.25619249e-02 5.70660548e-02 6.13642817e-02 1.94730070 0.01564796 8.25 -4.05512969e-03 3.58591039e-02 3.60876628e-02 1.68340302 0.00535612 8.50 -9.53689180e-03 4.11998073e-02 4.22891999e-02 1.79826899 0.00682337 8.75 -4.94787864e-02 5.33326786e-02 7.27497416e-02 2.31872699 0.01745215 9.00 -2.23720223e-02 5.11394753e-02 5.58189333e-02 1.98318218 0.01076497 9.25 -1.40181553e-02 5.88611281e-02 6.05073638e-02 1.80459740 0.01183488 9.50 -8.25898570e-03 6.28161797e-02 6.33567934e-02 1.70152512 0.01308908 9.75 -2.23517803e-02 6.68451929e-02 7.04832029e-02 1.89348972 0.01566978 10.00 1.37046576e-02 4.80927972e-02 5.00073473e-02 1.29319159 0.00759447 10.25 4.70646696e-02 2.83333077e-02 5.49350475e-02 0.54189466 0.00812453 10.50 1.52754620e-02 6.16824147e-02 6.35457317e-02 1.32803352 0.01120990 10.75 -7.73165313e-03 9.05252171e-02 9.08547929e-02 1.65599839 0.02279279 11.00 -1.51598776e-02 5.25667648e-02 5.47091094e-02 1.85157061 0.00800129 11.25 -7.63689533e-03 3.17000783e-02 3.26070105e-02 1.80720245 0.00270811 11.50 -2.31088113e-02 5.35587320e-02 5.83314232e-02 1.97813158 0.00748839 11.75 -4.38494989e-02 6.40916840e-02 7.76564389e-02 2.17081778 0.01246000 12.00 -1.92333485e-02 4.68024306e-02 5.06002886e-02 1.96070456 0.00540013 12.25 1.91436284e-05 4.18528652e-02 4.18528696e-02 1.57033892 0.00338255 12.50 1.54807950e-02 7.56381641e-02 7.72061324e-02 1.36891531 0.01157924 12.75 7.00178527e-03 8.78136975e-02 8.80923973e-02 1.49123011 0.01373989 13.00 -2.00588204e-02 9.37370191e-02 9.58591937e-02 1.78160727 0.01618624 13.25 -3.15621969e-03 9.50256992e-02 9.50781007e-02 1.60399850 0.01549216 13.50 1.93584156e-02 8.51894555e-02 8.73612705e-02 1.34735125 0.01202560 13.75 2.97914672e-02 8.22392855e-02 8.74690323e-02 1.22324725 0.01142947 14.00 1.09682382e-02 1.10303052e-01 1.10847037e-01 1.47168483 0.01838597 14.25 1.01526177e-02 9.21476878e-02 9.27052965e-02 1.46106126 0.01256306 14.50 1.17764873e-02 4.49970184e-02 4.65125501e-02 1.31482061 0.00310308 14.75 1.98222162e-02 5.16788353e-02 5.53499980e-02 1.20453744 0.00423541 15.00 1.64953497e-03 8.06445430e-02 8.06614114e-02 1.55034479 0.00810204 15.25 -8.28214468e-03 7.84802527e-02 7.89160566e-02 1.67593873 0.00780430 15.50 5.11147612e-03 4.03328141e-02 4.06554189e-02 1.44473591 0.00212815 15.75 1.01446894e-02 6.61386898e-02 6.69121888e-02 1.41859743 0.00532124 16.00 4.23433130e-03 1.06602062e-01 1.06686125e-01 1.53109628 0.01330343 16.25 -1.69008215e-02 1.07324678e-01 1.08647247e-01 1.72698745 0.01354832 16.50 -1.13657513e-03 4.06276617e-02 4.06435567e-02 1.59876443 0.00195316 16.75 5.56364274e-03 5.38415664e-02 5.41282587e-02 1.46782818 0.00326575 17.00 -1.31125786e-02 9.03984349e-02 9.13444949e-02 1.71484481 0.00851422 17.25 -1.44108106e-02 8.23961031e-02 8.36468126e-02 1.74394181 0.00729186 17.50 3.06562233e-02 9.55125139e-02 1.00311736e-01 1.26021780 0.00988993 17.75 2.43121076e-02 1.01234875e-01 1.04113296e-01 1.33510436 0.01073637 18.00 3.30375191e-02 1.23486790e-01 1.27829828e-01 1.30937979 0.01537408 18.25 2.12973849e-02 8.91248434e-02 9.16341439e-02 1.33623374 0.00748905 18.50 1.51900045e-02 2.65943822e-02 3.06267433e-02 1.05184257 0.00079543 18.75 5.17080244e-02 1.02127624e-01 1.14471705e-01 1.10211513 0.01118266 19.00 -1.75350300e-02 1.55036921e-01 1.56025396e-01 1.68342001 0.02133280 19.25 -1.84667664e-02 1.15599435e-01 1.17065156e-01 1.72920577 0.01202585 19.50 -5.94464507e-02 5.59444103e-02 8.16312289e-02 2.38653455 0.00568488 19.75 -1.68512036e-02 9.01512235e-02 9.17126281e-02 1.75558538 0.00648311 20.00 -2.22287710e-02 1.15926630e-01 1.18038561e-01 1.76024542 0.00991774 20.25 -6.32094443e-03 8.12774137e-02 8.15228331e-02 1.64841010 0.00481788 20.50 3.38069323e-02 6.81946409e-02 7.61145040e-02 1.11056110 0.00413979 20.75 2.72525025e-02 8.52882155e-02 8.95364652e-02 1.26151596 0.00557178 21.00 -1.08640533e-02 9.29388266e-02 9.35716471e-02 1.68716289 0.00618422 21.25 2.82379301e-02 1.16259776e-01 1.19639944e-01 1.33252385 0.01012747 21.50 3.11020104e-02 7.73587280e-02 8.33769024e-02 1.18852470 0.00489512 21.75 3.86151422e-02 8.07816664e-02 8.95366229e-02 1.12488793 0.00520693 22.00 5.62968015e-02 3.49547602e-02 6.62658669e-02 0.55564654 0.00284488 22.25 1.61481152e-02 1.20332805e-01 1.21411473e-01 1.43739783 0.00898460 22.50 -4.62234815e-02 1.29991066e-01 1.37964805e-01 1.91244211 0.01118383 22.75 -1.85743016e-02 1.40233217e-01 1.41457979e-01 1.70248274 0.01211393 23.00 1.07181763e-02 1.30150867e-01 1.30591453e-01 1.48862980 0.01061727 23.25 1.00170306e-02 1.77081145e-01 1.77364237e-01 1.51428909 0.01817626 23.50 -4.45298678e-02 2.04875148e-01 2.09658616e-01 1.78481876 0.02384953 23.75 1.22834164e-02 1.86233909e-01 1.86638558e-01 1.50493480 0.02041702 24.00 1.41130459e-02 1.66583342e-01 1.67180107e-01 1.48627752 0.01663153 24.25 -4.78076019e-02 1.65331895e-01 1.72105207e-01 1.85228003 0.01566650 24.50 -5.93225142e-02 1.69004639e-01 1.79113731e-01 1.90837167 0.01649269 24.75 -6.38076402e-02 9.87390908e-02 1.17561996e-01 2.14451298 0.00693917 25.00 -6.13528437e-02 1.27095731e-01 1.41129360e-01 2.02053223 0.00993273 25.25 -5.12602241e-02 5.54684156e-02 7.55271852e-02 2.31678602 0.00270526 25.50 -1.12604953e-03 5.87877192e-02 5.87985026e-02 1.58994849 0.00160356 25.75 -3.60217275e-02 1.25232108e-01 1.30309807e-01 1.85087519 0.00803485 26.00 -9.60788973e-02 8.78598008e-02 1.30194082e-01 2.40084868 0.00772977 26.25 1.33666437e-02 9.46243795e-02 9.55638026e-02 1.43046478 0.00423043 26.50 -2.90796755e-02 1.04377004e-01 1.08352141e-01 1.84250849 0.00522969 26.75 -3.71162666e-02 1.05130807e-01 1.11490376e-01 1.91018431 0.00539491 27.00 -3.23677034e-02 1.23338368e-01 1.27514788e-01 1.82743929 0.00678578 27.25 -9.31271775e-02 1.00794974e-01 1.37230820e-01 2.31667449 0.00800722 27.50 -5.78280016e-02 1.00867658e-01 1.16268492e-01 2.09135635 0.00549003 27.75 3.69946755e-02 1.09162922e-01 1.15261223e-01 1.24404941 0.00538871 28.00 -1.88255935e-02 1.29760536e-01 1.31119029e-01 1.71487061 0.00698577 28.25 -4.02760468e-03 1.56147621e-01 1.56199556e-01 1.59658418 0.01030841 28.50 -8.91356296e-03 1.09093698e-01 1.09457236e-01 1.65232081 0.00480603 28.75 7.75062330e-02 1.69555744e-01 1.86430594e-01 1.14204252 0.01390173 29.00 4.35699558e-02 1.71361670e-01 1.76813922e-01 1.32181482 0.01225284 29.25 -1.05622631e-01 1.98421964e-01 2.24783042e-01 2.05995910 0.01767629 29.50 -1.08239417e-01 1.55107840e-01 1.89140724e-01 2.18006665 0.01283348 29.75 1.90496364e-02 1.51945701e-01 1.53135185e-01 1.44607572 0.00775820 30.00 1.27063908e-03 8.49075262e-02 8.49170332e-02 1.55583247 0.00231818 30.25 -4.64987452e-02 7.92421812e-02 9.18773998e-02 2.10144808 0.00271235 30.50 3.69055992e-02 9.53458395e-02 1.02239192e-01 1.20148518 0.00352625 30.75 1.32304680e-01 6.95132583e-02 1.49454413e-01 0.48376277 0.00714593 31.00 4.25714626e-02 1.34359915e-01 1.40942953e-01 1.26395661 0.00656143 31.25 -8.22334265e-02 1.47228600e-01 1.68637472e-01 2.08017439 0.00997096 31.50 -4.44172068e-02 1.39119474e-01 1.46038065e-01 1.87984041 0.00700103 31.75 -6.37791104e-02 1.63064253e-01 1.75093477e-01 1.94363172 0.01028859 32.00 -1.50308340e-02 1.96986919e-01 1.97559541e-01 1.64695247 0.01241617 32.25 -1.17287064e-01 2.32779144e-01 2.60657601e-01 2.03752362 0.02515863 32.50 3.54951216e-02 1.46636919e-01 1.50871766e-01 1.33330324 0.00751551 32.75 1.07868445e-01 1.28254031e-02 1.08628230e-01 0.11834298 0.00359071 33.00 6.36179010e-02 1.12375505e-01 1.29133619e-01 1.05566202 0.00474508 33.25 7.47226766e-03 1.01715408e-01 1.01989504e-01 1.49746556 0.00311365 33.50 -8.97943645e-02 1.50549860e-01 1.75294861e-01 2.10859606 0.00826516 33.75 -5.50411249e-02 1.22243576e-01 1.34063482e-01 1.99386463 0.00441663 34.00 1.46774391e-02 8.10270078e-02 8.23456326e-02 1.39159691 0.00180939 34.25 3.87820461e-02 6.41121149e-02 7.49293693e-02 1.02677450 0.00147085 34.50 -1.23180104e-03 8.91481526e-02 8.91566623e-02 1.58461291 0.00204393 34.75 8.98854096e-03 2.34805650e-02 2.51422116e-02 1.20519819 0.00016653 35.00 -1.00363930e-02 2.43158195e-01 2.43365234e-01 1.61204807 0.01500111 35.25 3.53618943e-03 3.13068062e-01 3.13088032e-01 1.55950153 0.02390554 35.50 8.14813107e-02 8.81240544e-02 1.20021052e-01 0.82454404 0.00354295 35.75 7.23002466e-02 -8.23228115e-03 7.27674111e-02 -0.11337415 0.00124757 36.00 9.71887379e-02 6.37875162e-03 9.73978400e-02 0.06553862 0.00190411 36.25 2.60878212e-01 -2.16069927e-01 3.38738329e-01 -0.69172519 0.01796434 36.50 2.57405491e-01 -9.05305226e-01 9.41188153e-01 -1.29377689 0.13943622 36.75 2.55809714e-01 -3.53893029e-01 4.36667935e-01 -0.94490229 0.03600329 37.00 1.28189035e-01 3.07792685e-02 1.31832440e-01 0.23564751 0.00353777 37.25 1.86397656e-01 5.30236552e-03 1.86473058e-01 0.02843886 0.00713559 37.50 6.06487763e-02 3.26113400e-01 3.31705025e-01 1.38692247 0.02302087 37.75 1.28884031e-01 2.81675360e-01 3.09761363e-01 1.14167140 0.01892527 38.00 8.43615320e-02 1.08400817e-02 8.50551318e-02 0.12779528 0.00159434 38.25 1.24181787e-01 9.74712734e-02 1.57866289e-01 0.66547050 0.00560898 38.50 6.71917172e-02 1.77635212e-01 1.89918392e-01 1.20917349 0.00871797 38.75 2.79110624e-02 1.54324088e-01 1.56827777e-01 1.39187045 0.00558099 39.00 5.90930959e-02 1.03574059e-01 1.19245879e-01 1.05232066 0.00330405 39.25 1.33571449e-02 7.45470173e-02 7.57342136e-02 1.39350023 0.00121682 39.50 -7.19242536e-02 -7.79926124e-02 1.06094042e-01 -2.31573842 0.00230085 39.75 2.70410926e-02 2.11959858e-02 3.43582669e-02 0.66481151 0.00026423 40.00 3.50327644e-01 8.23550352e-02 3.59877493e-01 0.23088781 0.03174085 40.25 2.44894343e-01 1.46431743e-01 2.85334005e-01 0.53890227 0.01883305 40.50 1.38968096e-01 1.79281997e-01 2.26835107e-01 0.91140072 0.01172832 40.75 1.28805016e-01 2.52941502e-01 2.83848790e-01 1.09979322 0.01694388 41.00 2.71139067e-01 2.41885061e-01 3.63352138e-01 0.72843718 0.02604187 41.25 9.95702694e-02 2.06066697e-01 2.28861797e-01 1.12068338 0.00999956 41.50 1.18740693e-01 1.66567797e-01 2.04558508e-01 0.95148686 0.00793740 41.75 1.25166841e-01 1.71756527e-01 2.12525393e-01 0.94103727 0.00860648 42.00 1.59782112e-01 -6.08657065e-03 1.59897998e-01 -0.03807453 0.00509790 42.25 1.04568892e-01 1.82144326e-01 2.10026685e-01 1.04963937 0.00861739 42.50 1.41094855e-01 1.40960549e-01 1.99443312e-01 0.78492199 0.00765187 42.75 4.76525688e-01 7.27058700e-02 4.82040325e-01 0.15140725 0.05588776 43.00 7.59742928e-01 -1.26718017e-01 7.70238127e-01 -0.16526931 0.16903954 43.25 5.94791737e-01 -1.16554187e-01 6.06104025e-01 -0.19350600 0.07192100 43.50 5.64332421e-01 4.08531652e-02 5.65809210e-01 0.07226596 0.04993332 43.75 2.84577193e-01 -5.07689240e-04 2.84577645e-01 -0.00178401 0.01092712 44.00 6.09743802e-02 -4.64839006e-02 7.66722118e-02 -0.65135922 0.00060375 44.25 -3.13595232e-01 9.22453888e-02 3.26880989e-01 2.85550747 0.01253769 44.50 -1.66118038e-01 1.62635365e-01 2.32476804e-01 2.36678767 0.00798743 44.75 -1.37057375e-01 2.03029467e-01 2.44960586e-01 2.16458824 0.01209162 45.00 -1.83151362e-01 2.85405907e-01 3.39117904e-01 2.14133047 0.02435277 45.25 -1.54021816e-01 2.05374128e-01 2.56712392e-01 2.21427007 0.01166807 45.50 -1.98337283e-01 1.42278235e-01 2.44091732e-01 2.51931377 0.01090272 45.75 -1.75941147e-01 3.11252768e-01 3.57538211e-01 2.08528579 0.02400507 46.00 -1.89649444e-01 2.91583249e-01 3.47832866e-01 2.14746160 0.02393363 46.25 -3.90047006e-02 1.32816442e-01 1.38425337e-01 1.85643915 0.00332293 46.50 -1.15522868e-01 1.53838492e-01 1.92384549e-01 2.21489623 0.00601876 46.75 -8.16444102e-02 9.80559475e-02 1.27596154e-01 2.26511990 0.00316412 47.00 3.70600893e-02 1.32309789e-01 1.37402076e-01 1.29769407 0.00365347 47.25 1.87605353e-01 1.22162849e-01 2.23873915e-01 0.57719679 0.00880637 47.50 -1.24727968e-03 1.83018358e-01 1.83022608e-01 1.57761127 0.00579120 47.75 4.88785202e-03 1.76477221e-01 1.76544897e-01 1.54310662 0.00462258 48.00 3.73030260e-02 1.94142665e-01 1.97693930e-01 1.38096750 0.00594375 48.25 -2.38285310e-01 2.43170340e-01 3.40458078e-01 2.34604846 0.02381651 48.50 -2.19647333e-01 1.29576493e-01 2.55019643e-01 2.60861067 0.01279273 48.75 -3.14097964e-01 1.11692777e-01 3.33365876e-01 2.79993900 0.02062456 49.00 -1.90638720e-01 9.22223122e-02 2.11773644e-01 2.69102582 0.00911922 49.25 -1.10176800e-01 1.83201554e-01 2.13779645e-01 2.11224214 0.00830655 49.50 -1.37126182e-01 5.47549793e-01 5.64459357e-01 1.81618530 0.05032280 49.75 -1.35438022e-01 7.22282684e-01 7.34871236e-01 1.75615768 0.08918946 50.00 -3.39483610e-01 6.07486386e-01 6.95908637e-01 2.08039602 0.06545721 50.25 -3.90926971e-01 7.69846891e-02 3.98435113e-01 2.94715213 0.02614545 50.50 -3.44955447e-01 -4.55175203e-02 3.47945549e-01 -3.01039869 0.02124779 50.75 -1.01504237e-01 -1.99141052e-02 1.03439265e-01 -2.94786333 0.00191907 51.00 -5.01515310e-02 1.11858286e-02 5.13838381e-02 2.92214396 0.00043523 51.25 1.54714010e-01 -1.67584897e-01 2.28081395e-01 -0.82531158 0.00852545 51.50 1.72182490e-02 -3.78050287e-02 4.15414046e-02 -1.14342056 0.00023533 51.75 -1.41774699e-01 1.22776977e-01 1.87547998e-01 2.42788244 0.00440606 52.00 2.79146625e-02 9.52841554e-02 9.92889654e-02 1.28580861 0.00114674 52.25 -3.91099906e-02 6.49092549e-02 7.57812822e-02 2.11307650 0.00068686 52.50 1.34570135e-01 2.02898851e-01 2.43468817e-01 0.98517149 0.00794419 52.75 -9.42580354e-02 3.84920775e-01 3.96293553e-01 1.81094705 0.02475487 53.00 -1.78328957e-01 -9.80863512e-02 2.03524321e-01 -2.63872609 0.00701152 53.25 -3.19715630e-01 -2.27945077e-01 3.92653845e-01 -2.52222027 0.03493195 53.50 -1.86624525e-01 9.24001186e-02 2.08246237e-01 2.68186275 0.01041963 53.75 -1.86841079e-01 1.58758374e-01 2.45181178e-01 2.43727431 0.01852711 54.00 -3.25460101e-01 2.37137624e-01 4.02689124e-01 2.51191397 0.02943954 54.25 -2.35340480e-01 3.15705875e-01 3.93770670e-01 2.21137405 0.02895312 54.50 6.56117398e-02 7.03566621e-01 7.06619339e-01 1.47780936 0.06612786 54.75 1.60387120e-01 9.06383156e-01 9.20464260e-01 1.39565643 0.11124444 55.00 1.56495934e-01 2.52995432e-01 2.97485573e-01 1.01683263 0.01042781 55.25 -1.05577789e-02 1.89009578e-01 1.89304219e-01 1.62659677 0.00439945 55.50 1.57724424e-01 2.72155328e-01 3.14556062e-01 1.04555812 0.01277786 55.75 1.56921868e-01 1.17913618e-01 1.96285746e-01 0.64440680 0.00547123 56.00 4.42347187e-01 2.96797805e-01 5.32691253e-01 0.59096986 0.03766911 56.25 4.31834163e-01 2.17754280e-01 4.83629684e-01 0.46704534 0.03640896 56.50 1.83113406e-01 -2.51400111e-01 3.11018544e-01 -0.94127986 0.01595875 56.75 1.77103499e-01 -3.48169958e-01 3.90625100e-01 -1.10023706 0.02660752 57.00 5.74664696e-01 -1.31335589e-01 5.89481594e-01 -0.22468414 0.06968093 57.25 7.41410428e-01 -4.60725714e-01 8.72901831e-01 -0.55601928 0.16226756 57.50 1.94406791e+00 -1.35086344e+00 2.36732593e+00 -0.60727088 0.52954292 57.75 2.15634157e+00 -2.30069930e+00 3.15325644e+00 -0.81777554 0.56350114 58.00 1.40940724e-01 -2.98194545e+00 2.98527435e+00 -1.52356679 0.36642590 58.25 -1.10487085e+00 -1.44603998e+00 1.81982725e+00 -2.22323944 0.22850719 58.50 -1.72518424e+00 -6.31647462e-01 1.83718240e+00 -2.79061806 0.45403675 58.75 -1.70927886e+00 -4.52251845e-01 1.76809670e+00 -2.88293348 0.46171573 59.00 -1.46851109e+00 -4.73465771e-01 1.54294999e+00 -2.82970318 0.50036867 59.25 -1.45962150e+00 -4.05914612e-01 1.51501208e+00 -2.87035058 0.50981420 59.50 -1.24556948e+00 -1.30977353e-01 1.25243698e+00 -3.03682309 0.56788326 59.75 -1.10126329e+00 -1.55897792e-01 1.11224321e+00 -3.00096439 0.47855712 60.00 -9.41177054e-01 4.47195801e-02 9.42238870e-01 3.09411384 0.41091257 60.25 -9.03563105e-01 3.90846975e-02 9.04408038e-01 3.09836341 0.30473017 60.50 -9.12583605e-01 -8.12528965e-02 9.16193685e-01 -3.05279070 0.35103391 60.75 -8.74404844e-01 -1.16646527e-01 8.82150919e-01 -3.00897458 0.25887140 61.00 -8.94201348e-01 -1.98091403e-01 9.15880044e-01 -2.92358454 0.29206236 61.25 -6.89706541e-01 2.49225677e-03 6.89711044e-01 3.13797917 0.13299064 61.50 -5.24112462e-01 1.96259019e-01 5.59652995e-01 2.78329571 0.10265925 61.75 -5.49872418e-01 4.74513952e-02 5.51916036e-01 3.05551063 0.09224756 62.00 -6.57647798e-01 -3.08980966e-01 7.26615348e-01 -2.70237313 0.18295157 62.25 -6.04473730e-01 -2.98105606e-01 6.73984749e-01 -2.68342756 0.15126154 62.50 -6.95869499e-01 -2.04549785e-01 7.25310261e-01 -2.85569691 0.22034022 62.75 -6.98739423e-01 -2.63512556e-01 7.46776840e-01 -2.78095971 0.20886097 63.00 -8.65138869e-01 -3.06606988e-01 9.17863338e-01 -2.80100158 0.34631836 63.25 -8.01093311e-01 -2.90569341e-01 8.52162564e-01 -2.79363479 0.23473138 63.50 -7.40355850e-01 -4.39503360e-01 8.60981991e-01 -2.60586423 0.25960428 63.75 -6.77100572e-01 -4.79170090e-01 8.29499343e-01 -2.52573134 0.22834269 64.00 -7.32886467e-01 -6.39737540e-01 9.72824082e-01 -2.42395254 0.32871885 64.25 -1.03874018e+00 -7.29091952e-01 1.26907692e+00 -2.52959252 0.30655533 64.50 -1.52144972e+00 -7.92244457e-01 1.71536017e+00 -2.66150928 0.49734228 64.75 -1.36549177e+00 -4.99915486e-01 1.45412629e+00 -2.79064168 0.40674081 65.00 -1.41824275e+00 -3.14812816e-01 1.45276275e+00 -2.92316040 0.43545101 65.25 -1.52484387e+00 -1.94586315e-01 1.53720938e+00 -3.01466801 0.41311391 65.50 -1.46989351e+00 -3.31686500e-01 1.50685197e+00 -2.91965636 0.44431236 65.75 -1.31983465e+00 -1.85673918e-01 1.33283094e+00 -3.00183016 0.33612953 66.00 -1.42521868e+00 -5.54656587e-02 1.42629756e+00 -3.10269499 0.40599829 66.25 -1.17390111e+00 3.34199067e-02 1.17437673e+00 3.11313124 0.28103523 66.50 -1.22679368e+00 1.43199460e-01 1.23512300e+00 3.02539189 0.27875511 66.75 -7.41285625e-01 2.30035784e-01 7.76157741e-01 2.84069503 0.15438426 67.00 -6.63438147e-01 2.63498039e-01 7.13849698e-01 2.76352791 0.14327076 67.25 -1.09161788e+00 1.14195144e-01 1.09757466e+00 3.03736085 0.19790120 67.50 -1.15102542e+00 1.73321107e-01 1.16400160e+00 2.99213577 0.19099872 67.75 -6.29369506e-01 -1.48805087e-02 6.29545395e-01 -3.11795354 0.07491672 68.00 -6.27242552e-01 2.29829059e-02 6.27663472e-01 3.10496786 0.07146808 68.25 -1.01905372e+00 3.17636485e-01 1.06740968e+00 2.83943907 0.15309917 68.50 -8.15330667e-01 3.27588325e-01 8.78679809e-01 2.75954770 0.09640530 68.75 -2.96827196e-01 4.58734177e-01 5.46391278e-01 2.14509993 0.03725323 69.00 -3.82313684e-01 4.68990388e-01 6.05074985e-01 2.25472776 0.04561012 69.25 -8.60151734e-01 2.74020216e-02 8.60588099e-01 3.10974623 0.17313626 69.50 -8.12191887e-01 1.15230160e-01 8.20325333e-01 3.00065770 0.14997706 69.75 -6.93113806e-01 2.42496643e-01 7.34310132e-01 2.80503762 0.09286833 70.00 -5.54246952e-01 2.67863731e-01 6.15581564e-01 2.69139967 0.06228132 70.25 -5.97238658e-01 4.93129162e-02 5.99271039e-01 3.05921133 0.10158937 70.50 -6.01681361e-01 1.12849755e-01 6.12172792e-01 2.95618931 0.09912979 70.75 -8.35914902e-01 7.72390938e-02 8.39475789e-01 3.04945362 0.18052106 71.00 -8.57786471e-01 7.00836651e-02 8.60644729e-01 3.06007080 0.16840453 71.25 -8.41504397e-01 5.80460287e-02 8.43503996e-01 3.07272287 0.16576653 71.50 -8.88199388e-01 -8.12616711e-02 8.91908971e-01 -3.05035630 0.15456593 71.75 -9.98885994e-01 -3.61865268e-02 9.99541242e-01 -3.10538161 0.27148609 72.00 -9.07367466e-01 -3.15450779e-02 9.07915640e-01 -3.10684116 0.19280511 72.25 -8.45610195e-01 5.75039871e-02 8.47563160e-01 3.07369424 0.19364024 72.50 -9.86440521e-01 -2.07149967e-02 9.86658002e-01 -3.12059600 0.24994889 72.75 -1.08338453e+00 -7.78290546e-02 1.08617650e+00 -3.06987705 0.41627284 73.00 -1.06555970e+00 -3.77716952e-02 1.06622895e+00 -3.10615974 0.35967020 73.25 -1.09708861e+00 -1.15561275e-01 1.10315811e+00 -3.03664516 0.46319074 73.50 -9.46029910e-01 -1.91289459e-01 9.65175760e-01 -2.94208036 0.30865683 73.75 -9.80859265e-01 -1.78973384e-01 9.97053845e-01 -2.96111222 0.33459858 74.00 -1.11067812e+00 -5.88930344e-02 1.11223841e+00 -3.08861787 0.30979520 74.25 -1.27263191e+00 1.60730233e-02 1.27273340e+00 3.12896357 0.38638464 74.50 -1.01700310e+00 -1.05573254e-01 1.02246810e+00 -3.03815495 0.28759923 74.75 -1.18459973e+00 -1.35513944e-01 1.19232569e+00 -3.02769139 0.46166440 75.00 -1.12820847e+00 -1.06048461e-02 1.12825831e+00 -3.13219321 0.34826223 75.25 -1.17523886e+00 -5.99594256e-02 1.17676740e+00 -3.09061792 0.39056784 75.50 -1.23371764e+00 -2.65783137e-01 1.26202214e+00 -2.92940294 0.37896650 75.75 -1.41595583e+00 -1.67003235e-01 1.42577032e+00 -3.02419121 0.43097023 76.00 -1.18536520e+00 -2.12321853e-01 1.20423056e+00 -2.96435285 0.29146144 76.25 -1.20732590e+00 -1.05834537e-01 1.21195577e+00 -3.05415587 0.33870048 76.50 -1.04106170e+00 2.47457467e-01 1.07006760e+00 2.90822618 0.23832022 76.75 -1.15552849e+00 2.35760704e-01 1.17933422e+00 2.94032659 0.28731710 77.00 -1.21298142e+00 -1.02349616e-01 1.21729182e+00 -3.05741350 0.23945478 77.25 -1.42639347e+00 -1.77143826e-01 1.43735113e+00 -3.01803526 0.31146519 77.50 -1.42678906e+00 -2.74032157e-01 1.45286636e+00 -2.95184117 0.33000533 77.75 -1.51378074e+00 -1.81610380e-01 1.52463585e+00 -3.02219193 0.33602483 78.00 -1.24952946e+00 -1.20094999e-01 1.25528749e+00 -3.04577479 0.26752793 78.25 -1.07256785e+00 -8.86195273e-02 1.07622266e+00 -3.05915620 0.17521609 78.50 -1.20823726e+00 5.20653472e-02 1.20935854e+00 3.09852731 0.14471279 78.75 -1.38005278e+00 1.04181666e-01 1.38397958e+00 3.06624450 0.17089268 79.00 -2.25035644e+00 5.61475244e-01 2.31934443e+00 2.89707990 0.41031293 79.25 -2.26669215e+00 6.47588068e-01 2.35738491e+00 2.86330860 0.40172953 79.50 -1.70883625e+00 2.15323259e-01 1.72234882e+00 3.01624747 0.32337035 79.75 -2.05112669e+00 2.10637861e-01 2.06191392e+00 3.03925765 0.32114952 80.00 -3.69021020e+00 4.08391982e-01 3.71273960e+00 3.03137214 0.48551326 80.25 -4.92045223e+00 1.34753885e+00 5.10163808e+00 2.87428210 0.50307981 80.50 -5.97172178e+00 5.95603454e+00 8.43420467e+00 2.35750968 0.59708670 80.75 -2.20578252e+00 6.73196189e+00 7.08412220e+00 1.88743060 0.49278800 81.00 2.68884968e+00 4.53496426e+00 5.27217350e+00 1.03560245 0.62241961 81.25 2.22120024e+00 3.03235234e+00 3.75884174e+00 0.93858915 0.63664070 81.50 1.79336015e+00 2.06713480e+00 2.73663788e+00 0.85619662 0.67397939 81.75 1.38653727e+00 1.50096611e+00 2.04337585e+00 0.82500643 0.59844159 82.00 1.15977075e+00 1.03316592e+00 1.55322246e+00 0.72772917 0.55521744 82.25 8.77458887e-01 8.46631090e-01 1.21931058e+00 0.76751945 0.34231056 82.50 5.79104270e-01 6.94249154e-01 9.04070596e-01 0.87557939 0.22597857 82.75 2.22750525e-01 6.06091370e-01 6.45727919e-01 1.21859979 0.10128336 83.00 -3.31015391e-01 4.36068849e-01 5.47473497e-01 2.22008954 0.07866387 83.25 -2.39213976e-01 4.28756713e-01 4.90974180e-01 2.07970342 0.03614695 83.50 1.40093533e-01 1.22115171e+00 1.22916138e+00 1.45657322 0.14417028 83.75 8.67712133e-01 1.44222275e+00 1.68313125e+00 1.02916508 0.25234878 84.00 1.14584475e+00 1.19642729e+00 1.65662260e+00 0.80699031 0.35650665 84.25 1.10634677e+00 6.71076590e-01 1.29396560e+00 0.54523627 0.24731350 84.50 1.01918136e+00 4.86702719e-01 1.12942914e+00 0.44552099 0.26464369 84.75 7.05993896e-01 2.32662378e-01 7.43343234e-01 0.31834437 0.09336895 85.00 4.30338418e-01 1.74290102e-01 4.64293219e-01 0.38481535 0.04678072 85.25 2.33418745e-01 4.00153988e-02 2.36823865e-01 0.16978142 0.01389912 85.50 1.91220373e-01 5.17922283e-02 1.98110237e-01 0.26450484 0.01222282 85.75 6.51438432e-02 1.49388783e-01 1.62974626e-01 1.15958747 0.00719433 86.00 -1.03696946e-01 1.94797302e-01 2.20678602e-01 2.05997418 0.01471976 86.25 1.68822001e-01 -2.58693673e-02 1.70792541e-01 -0.15205183 0.00834397 86.50 3.29196155e-01 2.40076436e-02 3.30070410e-01 0.07279920 0.03752321 86.75 -6.56964850e-02 3.47931568e-01 3.54079658e-01 1.75741927 0.03581576 87.00 -1.48124956e-01 3.66666846e-01 3.95456165e-01 1.95472641 0.04645377 87.25 -1.63707820e-01 -7.68366470e-02 1.80842807e-01 -2.70276238 0.00742235 87.50 -1.30955302e-01 -4.65181656e-02 1.38972051e-01 -2.80027358 0.00417943 87.75 1.35223891e-01 -1.38160589e-01 1.93323172e-01 -0.79613976 0.01134123 88.00 1.86596092e-01 -9.40496043e-02 2.08957962e-01 -0.46686460 0.01409415 88.25 2.45770988e-01 -5.12702247e-02 2.51061774e-01 -0.20566029 0.01498780 88.50 1.43825705e-01 8.07322553e-02 1.64934928e-01 0.51149268 0.00721533 88.75 -3.20377400e-01 -1.04314869e-01 3.36932146e-01 -2.82681821 0.02966600 89.00 -2.62810928e-01 -3.14120153e-02 2.64681504e-01 -3.02263374 0.01725637 89.25 -1.23732069e-01 1.00446154e-01 1.59370809e-01 2.45969565 0.01151434 89.50 -1.88155627e-01 1.25117700e-01 2.25957914e-01 2.55476613 0.01923172 89.75 1.04530492e-02 1.68427859e-01 1.68751918e-01 1.50881335 0.00941146 90.00 2.25189775e-02 1.14806674e-01 1.16994345e-01 1.37710836 0.00423022 90.25 5.30245712e-03 -2.04490779e-01 2.04559514e-01 -1.54487208 0.01645098 90.50 -2.75615617e-02 -2.60638063e-01 2.62091281e-01 -1.67615128 0.02429313 90.75 -1.28838573e-01 8.66621450e-02 1.55273003e-01 2.54946517 0.00900911 91.00 -1.46441588e-01 -1.70650623e-01 2.24870571e-01 -2.27999533 0.01436842 91.25 -1.18166710e-02 -2.09640241e-01 2.09973008e-01 -1.62710317 0.01099164 91.50 -1.76814684e-01 -2.40731668e-01 2.98689083e-01 -2.20429605 0.01505697 91.75 -9.18920694e-02 -3.55874834e-01 3.67547344e-01 -1.82349129 0.02822993 92.00 -3.42237534e-02 -2.88799173e-01 2.90819923e-01 -1.68874988 0.01509626 92.25 6.47880584e-02 -4.69022665e-01 4.73476243e-01 -1.43353081 0.05088363 92.50 3.25878154e-02 -5.68527336e-01 5.69460532e-01 -1.51353928 0.05766826 92.75 2.19807433e-01 -3.21427341e-01 3.89398053e-01 -0.97099311 0.03915747 93.00 1.98184961e-01 -2.28395720e-01 3.02393591e-01 -0.85610085 0.01904485 93.25 4.80036464e-02 -3.92848565e-01 3.95770571e-01 -1.44920534 0.03363717 93.50 -3.97497698e-02 -5.15812299e-01 5.17341640e-01 -1.64770679 0.04852225 93.75 -2.69285593e-01 -6.54073581e-01 7.07337954e-01 -1.96135262 0.12714673 94.00 -9.87492777e-02 -6.65650723e-01 6.72935588e-01 -1.71807218 0.09203818 94.25 3.76284724e-02 -5.00248915e-01 5.01662116e-01 -1.49571821 0.06339654 94.50 2.32969459e-02 -4.13570367e-01 4.14226020e-01 -1.51452452 0.02815983 94.75 -3.86546604e-01 -4.53547590e-01 5.95922556e-01 -2.27660881 0.06127910 95.00 -6.11019927e-02 -3.30388897e-01 3.35991483e-01 -1.75366970 0.01529972 95.25 2.60247338e-02 -2.99745776e-01 3.00873424e-01 -1.48419082 0.01849852 95.50 9.19796974e-02 -3.20642786e-01 3.33574671e-01 -1.29143743 0.02802777 95.75 1.56226729e-01 -3.72688539e-01 4.04108325e-01 -1.17385840 0.05534549 96.00 1.29542509e-01 -4.80426264e-01 4.97584824e-01 -1.30741934 0.07309348 96.25 3.36884078e-01 -4.22482380e-01 5.40353813e-01 -0.89764764 0.11669604 96.50 2.93198393e-01 -6.61609753e-01 7.23666196e-01 -1.15364582 0.12763113 96.75 6.04133370e-01 -8.67154011e-01 1.05685061e+00 -0.96229852 0.19927019 97.00 3.16444283e-01 -9.70589058e-01 1.02087223e+00 -1.25563019 0.11726244 97.25 4.58424169e-01 -1.04666045e+00 1.14265078e+00 -1.15797680 0.11141490 97.50 5.55676258e-01 -4.18342709e-01 6.95547788e-01 -0.64532473 0.02458238 97.75 -3.38078351e-01 -4.08078145e-01 5.29928999e-01 -2.26265444 0.01055911 98.00 -7.91579284e-01 5.10760424e-01 9.42058370e-01 2.56856932 0.03846649 98.25 -1.16638362e+00 9.97003416e-01 1.53442712e+00 2.43432909 0.11664673 98.50 -1.74010779e+00 -3.77876134e-01 1.78066434e+00 -2.92775596 0.24745250 98.75 -1.76894538e+00 -6.67173024e-01 1.89057864e+00 -2.78093083 0.27608454 99.00 -2.03038668e+00 -3.42744038e-01 2.05911232e+00 -2.97436195 0.34050405 99.25 -1.93110478e+00 -2.95680041e-01 1.95361008e+00 -2.98965819 0.34551429 99.50 -1.23370637e+00 -2.24921657e-01 1.25404192e+00 -2.96125947 0.19382380 99.75 -1.30183652e+00 -4.94556325e-01 1.39261060e+00 -2.77854066 0.24377414 100.00 -1.24772668e+00 -3.68843747e-01 1.30110245e+00 -2.85416583 0.17258962 100.25 -1.33845099e+00 -3.31726849e-01 1.37894661e+00 -2.89864433 0.24305321 100.50 -1.62951561e+00 -2.68955526e-01 1.65156235e+00 -2.97801499 0.52543131 100.75 -1.63018694e+00 -2.87753544e-01 1.65538864e+00 -2.96687673 0.48225080 101.00 -1.72317157e+00 -4.29386535e-01 1.77586403e+00 -2.89738227 0.53650960 101.25 -1.48166984e+00 -3.81615254e-01 1.53002475e+00 -2.88951375 0.43172980 101.50 -1.14355493e+00 -5.16598338e-01 1.25482736e+00 -2.71728627 0.44656865 101.75 -9.30608050e-01 -4.59549443e-01 1.03789067e+00 -2.68290421 0.30879570 102.00 -7.98525620e-01 -3.26985437e-01 8.62880433e-01 -2.75293513 0.20814276 102.25 -9.44351533e-01 -5.77891064e-01 1.10713951e+00 -2.59243643 0.28787895 102.50 -1.29362471e+00 -5.59515246e-01 1.40944039e+00 -2.73337194 0.45634987 102.75 -6.19521543e-01 -3.30005836e-01 7.01933610e-01 -2.65214525 0.11785478 103.00 6.52731304e-01 -2.84602068e-01 7.12078993e-01 -0.41116518 0.10227565 103.25 9.14706422e-01 -1.16208826e+00 1.47889721e+00 -0.90395667 0.36336272 103.50 7.68006127e-01 -2.01401233e+00 2.15547653e+00 -1.20648643 0.76363519 103.75 7.71348725e-01 -2.22703461e+00 2.35683305e+00 -1.23737074 0.72977551 104.00 6.33410529e-01 -2.53901348e+00 2.61682982e+00 -1.32631550 0.77254887 104.25 8.63647944e-01 -2.96920092e+00 3.09225515e+00 -1.28773768 0.72283429 104.50 1.00594490e+00 -3.54153563e+00 3.68163004e+00 -1.29404342 0.74057679 104.75 8.44718441e-01 -4.23386187e+00 4.31730652e+00 -1.37386727 0.59422732 105.00 2.60039037e-01 -5.02222467e+00 5.02895227e+00 -1.51906486 0.52672781 105.25 -3.51205872e+00 -4.60940741e+00 5.79492823e+00 -2.22189079 0.53836569 105.50 -6.24591125e+00 -3.98560678e+00 7.40921513e+00 -2.57361819 0.76489947 105.75 -6.28692136e+00 -2.36451132e+00 6.71686638e+00 -2.78185792 0.82199033 106.00 -6.17284122e+00 -9.75695015e-01 6.24947594e+00 -2.98482705 0.82816182 106.25 -3.93263487e+00 3.52590592e-02 3.93279293e+00 3.13262713 0.47421451 106.50 -2.50742265e+00 -9.05470616e-01 2.66590424e+00 -2.79504940 0.43930159 106.75 -2.87048456e+00 -1.28261790e+00 3.14400863e+00 -2.72137823 0.74623741 107.00 -2.98598220e+00 -1.33395161e+00 3.27040007e+00 -2.72145475 0.81348924 107.25 -2.98884687e+00 -9.98911623e-01 3.15135368e+00 -2.81905056 0.85004872 107.50 -2.88706590e+00 -1.04013315e+00 3.06871740e+00 -2.79579503 0.84763301 107.75 -2.69701364e+00 -8.63985047e-01 2.83202273e+00 -2.83157335 0.83891728 108.00 -2.77000995e+00 -7.60982280e-01 2.87263802e+00 -2.87348505 0.85622191 108.25 -2.63245086e+00 -6.70759503e-01 2.71656325e+00 -2.89209754 0.82633495 108.50 -2.56588782e+00 -5.67770890e-01 2.62795435e+00 -2.92382503 0.85254133 108.75 -2.57148228e+00 -4.03067656e-01 2.60288007e+00 -2.98611249 0.86619922 109.00 -2.44202286e+00 -2.96621080e-01 2.45997148e+00 -3.02071946 0.84880758 109.25 -1.81943578e+00 -1.73340108e-01 1.82767430e+00 -3.04660799 0.63194912 109.50 -1.21815122e+00 -9.48993077e-02 1.22184217e+00 -3.06384531 0.36651896 109.75 -1.95657239e+00 -8.22590947e-01 2.12245881e+00 -2.74360388 0.47446309 110.00 -2.37737700e+00 -6.08539150e-01 2.45402553e+00 -2.89100233 0.66684238 110.25 -1.86650471e+00 -2.53278417e-01 1.88361084e+00 -3.00671982 0.68871234 110.50 -1.65257470e+00 -2.05224981e-01 1.66526887e+00 -3.01804021 0.58969816 110.75 -1.76709506e+00 4.12821336e-01 1.81467529e+00 2.91209285 0.53806934 111.00 -2.21568532e+00 4.58403875e-01 2.26260813e+00 2.93758064 0.62873729 111.25 -2.49842736e+00 6.99537993e-01 2.59451203e+00 2.86859199 0.70536590 111.50 -2.01549703e+00 1.03170904e+00 2.26421108e+00 2.66847982 0.58320295 111.75 -1.41595049e+00 1.82472984e+00 2.30966551e+00 2.23071721 0.56099398 112.00 -1.74708844e+00 2.02634494e+00 2.67551711e+00 2.28232321 0.62265905 112.25 -1.78807047e+00 2.42515722e+00 3.01306879e+00 2.20612031 0.64364464 112.50 -1.59000620e+00 2.46632049e+00 2.93442609e+00 2.14342792 0.56108433 112.75 -2.18177749e+00 2.44655201e+00 3.27807409e+00 2.29904941 0.48864333 113.00 -1.53437987e+00 2.23846652e+00 2.71386329e+00 2.17169729 0.43828364 113.25 -1.34524939e+00 2.06998584e+00 2.46871167e+00 2.14708956 0.52172987 113.50 -1.60643443e+00 1.87728897e+00 2.47079854e+00 2.27860201 0.64805348 113.75 -1.53716887e+00 1.49753590e+00 2.14604332e+00 2.36925366 0.67362473 114.00 -1.82714461e+00 1.35204218e+00 2.27298823e+00 2.50453818 0.59371493 114.25 -2.36380030e+00 9.80901366e-01 2.55924195e+00 2.74824983 0.69839915 114.50 -2.58743595e+00 6.20066643e-01 2.66069680e+00 2.90638316 0.63128062 114.75 -2.58669364e+00 4.25504988e-01 2.62145732e+00 2.97855512 0.58373032 115.00 -2.59037757e+00 7.21132639e-01 2.68888234e+00 2.87007845 0.57812343 115.25 -2.89167934e+00 6.90021595e-01 2.97286717e+00 2.90734995 0.59276427 115.50 -2.21994236e+00 9.92519324e-01 2.43171517e+00 2.72115933 0.40489196 115.75 -1.40945482e+00 9.03428536e-01 1.67414038e+00 2.57158646 0.21099678 116.00 8.34817850e-01 3.34667015e-01 8.99401387e-01 0.38127017 0.02754472 116.25 2.12212217e+00 -1.27850915e+00 2.47749635e+00 -0.54223170 0.18151975 116.50 1.19526364e+00 -2.06272024e+00 2.38400293e+00 -1.04561678 0.17036796 116.75 3.32363682e-01 -2.46255321e+00 2.48488107e+00 -1.43663990 0.15608974 117.00 -1.57958384e+00 -4.28919265e+00 4.57080503e+00 -1.92365430 0.36761669 117.25 -3.19843701e+00 -4.07337507e+00 5.17903310e+00 -2.23645098 0.49553273 117.50 -3.45596485e+00 -3.51721322e+00 4.93097170e+00 -2.34741129 0.65963785 117.75 -3.69014998e+00 -3.50366138e+00 5.08850174e+00 -2.38211216 0.75546117 118.00 -3.39583036e+00 -3.47522867e+00 4.85889681e+00 -2.34463954 0.76073952 118.25 -3.61100683e+00 -3.99118734e+00 5.38228081e+00 -2.30622680 0.75499265 118.50 -4.90752558e+00 -3.12009677e+00 5.81539432e+00 -2.57528039 0.79093753 118.75 -4.80205002e+00 -2.69624339e+00 5.50721462e+00 -2.62998021 0.78748214 119.00 -3.72794603e+00 -1.87977328e+00 4.17506038e+00 -2.67456013 0.74236701 119.25 -3.05131335e+00 -1.39390591e+00 3.35462171e+00 -2.71308037 0.67511276 119.50 -5.84813889e-01 -2.02134246e+00 2.10424158e+00 -1.85242597 0.47152240 119.75 2.13044239e-02 -2.76347139e+00 2.76355351e+00 -1.56308718 0.56120609 120.00 -2.71504377e-01 -5.63190133e+00 5.63844191e+00 -1.61896733 0.74846214 120.25 -1.24771894e+00 -6.25563926e+00 6.37885767e+00 -1.76766786 0.77286354 120.50 -3.65514476e+00 -6.60500765e+00 7.54892107e+00 -2.07623845 0.75431472 120.75 -5.17544626e+00 -5.73894613e+00 7.72791994e+00 -2.30461123 0.80663780 121.00 -5.58140145e+00 -3.93120097e+00 6.82688679e+00 -2.52796027 0.89256424 121.25 -5.12562860e+00 -3.72000643e+00 6.33328638e+00 -2.51378262 0.90808250 121.50 -4.10494035e+00 -3.59328454e+00 5.45547698e+00 -2.42256101 0.85384863 121.75 -4.28645356e+00 -3.45245737e+00 5.50392097e+00 -2.46354680 0.79924120 122.00 -4.35367503e+00 -3.58773347e+00 5.64148187e+00 -2.45234616 0.71745989 122.25 -4.44333233e+00 -4.57211362e+00 6.37553333e+00 -2.34191094 0.63446019 122.50 -7.73347209e+00 -6.31874918e+00 9.98665018e+00 -2.45653251 0.78034996 122.75 -9.24027553e+00 -5.06772714e+00 1.05387167e+01 -2.63994872 0.77246622 123.00 -8.99780756e+00 4.56419254e-01 9.00937619e+00 3.09091049 0.67001538 123.25 -6.75737233e+00 2.65856067e+00 7.26154430e+00 2.76676189 0.60182861 123.50 -3.23756316e+00 1.81612146e+00 3.71215738e+00 2.63037898 0.39362558 123.75 -2.62672421e+00 8.61042295e-01 2.76424925e+00 2.82482962 0.25660411 124.00 -1.69220569e+00 5.59814701e-01 1.78240079e+00 2.82210622 0.09780340 124.25 -1.60305973e-01 1.11649723e+00 1.12794684e+00 1.71340110 0.05768236 124.50 8.79710166e-01 8.04146697e-01 1.19186488e+00 0.74055302 0.15531807 124.75 1.23039890e+00 8.92819757e-01 1.52020018e+00 0.62772389 0.29785629 125.00 1.52745048e+00 1.36361195e+00 2.04756991e+00 0.72878802 0.51954158 125.25 1.86197129e+00 1.83667358e+00 2.61539804e+00 0.77855855 0.45359192 125.50 3.19162217e+00 2.04800346e+00 3.79219861e+00 0.57050485 0.51977298 125.75 4.22937787e+00 1.60975045e+00 4.52536559e+00 0.36368137 0.44908574 126.00 6.21890346e+00 9.49441137e-01 6.29096167e+00 0.15150035 0.53737873 126.25 6.85845355e+00 6.28890355e-02 6.85874187e+00 0.00916931 0.46661536 126.50 7.36565178e+00 4.02057238e-01 7.37661685e+00 0.05453131 0.32396390 126.75 1.04723903e+01 1.63639556e+00 1.05994693e+01 0.15500463 0.29506744 127.00 1.30901202e+01 3.75274127e+00 1.36174268e+01 0.27919689 0.33085314 127.25 1.44711767e+01 1.42226079e+00 1.45409003e+01 0.09796769 0.29664261 127.50 1.86915175e+01 -1.90883962e+00 1.87887332e+01 -0.10177049 0.34754186 127.75 1.76800502e+01 -6.82843553e+00 1.89528813e+01 -0.36857321 0.29947999 128.00 1.91473337e+01 -2.63670693e+00 1.93280266e+01 -0.13684555 0.24956905 128.25 3.11630995e+01 -5.03328123e+00 3.15669557e+01 -0.16013126 0.37441958 128.50 4.00678221e+01 -5.05682691e+00 4.03856641e+01 -0.12554294 0.45596179 128.75 5.13114537e+01 -1.05894510e+01 5.23927643e+01 -0.20351872 0.42577368 129.00 5.28709429e+01 -1.36539242e+01 5.46055514e+01 -0.25272823 0.43049174 129.25 2.56080573e+01 -1.27771293e+01 2.86186588e+01 -0.46280692 0.23996983 129.50 1.65996025e+01 -1.07677259e+01 1.97861246e+01 -0.57544230 0.16764091 129.75 1.95415986e+01 2.81159438e+00 1.97428249e+01 0.14289676 0.12507474 130.00 1.01215987e+01 1.14905357e+01 1.53127127e+01 0.84865479 0.04542446 130.25 -1.46449337e+01 -5.58460176e+00 1.56736039e+01 -2.77728104 0.04764185 130.50 -1.32238837e+01 -2.15180414e+01 2.52566269e+01 -2.12184475 0.17825839 130.75 2.06616104e+00 -4.22970122e+01 4.23474469e+01 -1.52198626 0.59025572 131.00 9.93567123e+00 -4.38239147e+01 4.49360997e+01 -1.34784725 0.68482929 131.25 1.66484720e+01 -4.29983530e+01 4.61088926e+01 -1.20138281 0.63081420 131.50 1.40515111e+01 -4.69129088e+01 4.89720939e+01 -1.27977689 0.66396938 131.75 1.05202405e+01 -4.11505498e+01 4.24740298e+01 -1.32050479 0.71269185 132.00 7.29683684e+00 -3.38396993e+01 3.46174678e+01 -1.35841857 0.67730714 132.25 8.34970432e+00 -2.10045698e+01 2.26033077e+01 -1.19243103 0.67756122 132.50 1.35402285e+01 -1.55164055e+01 2.05936064e+01 -0.85330481 0.67897671 132.75 2.09026165e+01 -1.37118696e+01 2.49986949e+01 -0.58057333 0.85335547 133.00 2.07571460e+01 -1.28481563e+01 2.44117642e+01 -0.55425506 0.75748507 133.25 6.76351315e+00 -8.12019157e+00 1.05679999e+01 -0.87629889 0.26735016 133.50 6.95090947e+00 -5.62941215e+00 8.94457509e+00 -0.68073720 0.38986455 133.75 1.20218134e+01 -5.18548116e+00 1.30924869e+01 -0.40722786 0.70237615 134.00 1.12923111e+01 -5.78029320e+00 1.26857431e+01 -0.47310533 0.68509050 134.25 9.27583884e+00 -4.82352089e+00 1.04550246e+01 -0.47952648 0.74559367 134.50 1.01609624e+01 -3.62499032e+00 1.07882210e+01 -0.34268133 0.75118102 134.75 1.11773816e+01 -2.11618503e+00 1.13759439e+01 -0.18711274 0.71141033 135.00 1.15283012e+01 -1.87025328e+00 1.16790229e+01 -0.16083027 0.68087303 135.25 1.40461773e+01 -2.24306739e+00 1.42241502e+01 -0.15835530 0.79575851 135.50 1.43402782e+01 -3.28851166e+00 1.47125078e+01 -0.22542240 0.84648731 135.75 1.50493496e+01 -3.80760144e+00 1.55235547e+01 -0.24780744 0.86294628 136.00 1.49614516e+01 -5.35151987e+00 1.58897388e+01 -0.34350663 0.85477863 136.25 1.50954852e+01 -7.26321260e+00 1.67519531e+01 -0.44845528 0.88003364 136.50 1.33394033e+01 -9.35612064e+00 1.62934549e+01 -0.61165807 0.87290273 136.75 1.06373955e+01 -1.01051470e+01 1.46720203e+01 -0.75974404 0.85194544 137.00 4.93857024e+00 -7.89344355e+00 9.31106476e+00 -1.01172634 0.61861038 137.25 2.07868139e+00 -5.92630277e+00 6.28028509e+00 -1.23344890 0.32765748 137.50 2.31862857e+00 -6.79042249e+00 7.17536591e+00 -1.24175353 0.50624594 137.75 3.02650977e+00 -6.55200051e+00 7.21723438e+00 -1.13807284 0.68689298 138.00 3.34629939e+00 -4.33901037e+00 5.47948269e+00 -0.91385681 0.76529424 138.25 3.59256636e+00 -3.78339738e+00 5.21733925e+00 -0.81126440 0.84097132 138.50 3.86401655e+00 -2.31506298e+00 4.50445785e+00 -0.53978236 0.88703010 138.75 4.15373799e+00 -1.66279581e+00 4.47419593e+00 -0.38077628 0.93051905 139.00 4.45015578e+00 -1.12822969e+00 4.59094638e+00 -0.24829438 0.95383655 139.25 4.65388493e+00 -7.92651342e-01 4.72090469e+00 -0.16870150 0.96677345 139.50 4.74692784e+00 -2.42611668e-01 4.75312364e+00 -0.05106476 0.96585554 139.75 4.87740663e+00 -3.39685801e-02 4.87752491e+00 -0.00696436 0.97078718 140.00 5.11990244e+00 4.13827052e-01 5.13659944e+00 0.08065181 0.95637106 140.25 5.23736181e+00 5.48740316e-01 5.26603025e+00 0.10439330 0.95066837 140.50 5.08911446e+00 9.10533412e-01 5.16992815e+00 0.17704455 0.92076223 140.75 5.21578574e+00 9.79699721e-01 5.30699844e+00 0.18567018 0.92073406 141.00 5.45294083e+00 1.18175515e+00 5.57952587e+00 0.21341850 0.91739951 141.25 5.29930529e+00 1.26909111e+00 5.44914937e+00 0.23505565 0.85299149 141.50 5.33523171e+00 1.76622385e+00 5.61998613e+00 0.31969337 0.74825712 141.75 5.43069025e+00 1.54488575e+00 5.64615521e+00 0.27715185 0.67787563 142.00 5.46468722e+00 1.63673962e+00 5.70453530e+00 0.29100907 0.61114775 142.25 5.10678509e+00 1.98798884e+00 5.48008701e+00 0.37123430 0.51381330 142.50 5.53142944e+00 3.61392514e+00 6.60735700e+00 0.57872228 0.44427293 142.75 5.82379317e+00 4.37552309e+00 7.28435098e+00 0.64434436 0.51058960 143.00 8.19463547e+00 2.87629363e+00 8.68476342e+00 0.33756287 0.52487971 143.25 1.01082397e+01 3.35525822e+00 1.06505525e+01 0.32048972 0.57600434 143.50 1.15426672e+01 1.54578303e+00 1.16457122e+01 0.13312697 0.50182652 143.75 1.35095395e+01 5.25674821e-01 1.35197630e+01 0.03889176 0.48662107 144.00 1.28926654e+01 3.10699190e-01 1.28964087e+01 0.02409425 0.44406370 144.25 1.21785298e+01 -1.63912561e+00 1.22883408e+01 -0.13378744 0.36751679 144.50 1.13749239e+01 -9.10082311e+00 1.45675624e+01 -0.67478833 0.31709856 144.75 1.11862920e+01 -1.27809340e+01 1.69848580e+01 -0.85183452 0.44925847 145.00 8.60724234e+00 -1.45969688e+01 1.69456814e+01 -1.03801478 0.51162498 145.25 3.79184402e+00 -1.32705294e+01 1.38016315e+01 -1.29247826 0.43511354 145.50 9.04171295e-01 -1.44046173e+01 1.44329666e+01 -1.50810902 0.59617275 145.75 -4.20310567e+00 -1.30633043e+01 1.37228283e+01 -1.88208504 0.60977468 146.00 -6.41879127e+00 -1.02822953e+01 1.21213233e+01 -2.12886092 0.65351115 146.25 -6.43120383e+00 -7.02682273e+00 9.52557717e+00 -2.31196583 0.54243941 146.50 -5.12306807e+00 -5.34164408e+00 7.40128286e+00 -2.33531057 0.52869293 146.75 -3.58173240e+00 -4.15710180e+00 5.48728552e+00 -2.28198270 0.38751344 147.00 -2.88015084e+00 -3.53192214e+00 4.55738334e+00 -2.25489490 0.41183495 147.25 -2.55866198e+00 -3.31076762e+00 4.18424824e+00 -2.22874952 0.42393321 147.50 -2.44257615e+00 -2.82860247e+00 3.73726774e+00 -2.28309159 0.42787063 147.75 -2.01177983e+00 -1.85579116e+00 2.73700912e+00 -2.39650511 0.29082737 148.00 -2.20152082e+00 -1.60878885e+00 2.72670048e+00 -2.51051766 0.33894903 148.25 -2.53670924e+00 -1.85165331e+00 3.14062315e+00 -2.51105204 0.42656378 148.50 -2.58761852e+00 -1.84547492e+00 3.17829314e+00 -2.52206620 0.48748658 148.75 -2.67859535e+00 -1.07921534e+00 2.88783289e+00 -2.75858580 0.46174062 149.00 -2.76057080e+00 -7.34721017e-01 2.85667046e+00 -2.88147435 0.51809641 149.25 -3.02938086e+00 5.05475989e-02 3.02980255e+00 3.12490842 0.54934617 149.50 -3.25882369e+00 6.05985666e-01 3.31468709e+00 2.95774029 0.62342322 149.75 -2.29899519e+00 8.36113579e-01 2.44631658e+00 2.79277735 0.44002647 150.00 -1.88092349e+00 1.03943294e+00 2.14902164e+00 2.63674137 0.35203691 150.25 -1.47922816e+00 1.39048763e+00 2.03016546e+00 2.38710775 0.31811541 150.50 -1.41493992e+00 1.16285034e+00 1.83146824e+00 2.45367742 0.29482485 150.75 -5.87341334e-01 1.93852889e+00 2.02555278e+00 1.86498758 0.36882744 151.00 -1.39963597e-01 1.71090853e+00 1.71662396e+00 1.65242116 0.31545622 151.25 -5.56661049e-02 1.46122577e+00 1.46228570e+00 1.60887340 0.22774206 151.50 -4.64032169e-01 1.28051976e+00 1.36200466e+00 1.91845547 0.21325587 151.75 -1.57653225e-01 7.11271075e-01 7.28533514e-01 1.78891990 0.08699185 152.00 -1.04143299e-01 6.06716266e-01 6.15589517e-01 1.74079042 0.06412159 152.25 -2.47244897e-03 6.84871000e-01 6.84875463e-01 1.57440641 0.10762846 152.50 7.47896601e-02 9.59401823e-01 9.62312502e-01 1.49299919 0.17380420 152.75 -1.35688690e-01 1.60819272e+00 1.61390683e+00 1.65497036 0.34188654 153.00 -1.95664271e-01 1.40094524e+00 1.41454306e+00 1.70956457 0.26209153 153.25 -1.15820585e-02 8.00937810e-01 8.01021547e-01 1.58525594 0.12907545 153.50 -1.43246224e-03 1.02130548e+00 1.02130648e+00 1.57219891 0.16306607 153.75 -3.56155340e-01 1.47035557e+00 1.51287545e+00 1.80844307 0.35564616 154.00 -3.38338525e-01 1.18304516e+00 1.23047503e+00 1.84935044 0.21781268 154.25 -2.61452332e-01 1.08511610e+00 1.11616947e+00 1.80723381 0.23419391 154.50 -2.78160553e-01 1.28902688e+00 1.31869769e+00 1.78332853 0.22840640 154.75 -1.13373948e-01 1.15212893e+00 1.15769371e+00 1.66888441 0.12999315 155.00 -1.03754573e-01 1.37224887e+00 1.37616568e+00 1.64626189 0.12692579 155.25 -8.27620977e-01 1.59022615e+00 1.79270067e+00 2.05066373 0.25431323 155.50 -2.27953813e-01 1.47635595e+00 1.49385067e+00 1.72398960 0.17161292 155.75 3.30729644e-01 1.37590431e+00 1.41509533e+00 1.33489911 0.16398467 156.00 5.23377125e-03 1.80920024e+00 1.80920781e+00 1.56790347 0.18718443 156.25 1.06490766e-01 1.93119697e+00 1.93413081e+00 1.51570975 0.33281517 156.50 1.30624967e-01 1.47587212e+00 1.48164145e+00 1.48251938 0.19349291 156.75 -2.56854300e-01 1.28303230e+00 1.30848997e+00 1.76837762 0.20302185 157.00 -3.83219442e-01 1.39568116e+00 1.44733653e+00 1.83876757 0.21367092 157.25 -4.79624948e-01 1.39552577e+00 1.47564639e+00 1.90183663 0.26768065 157.50 -5.73554874e-01 1.44870065e+00 1.55810743e+00 1.94777176 0.24941070 157.75 -8.04466009e-01 1.47724215e+00 1.68208500e+00 2.06946329 0.31326803 158.00 -3.09914914e-01 1.47344751e+00 1.50568749e+00 1.77810762 0.24520863 158.25 -2.24824905e-01 1.32309395e+00 1.34205955e+00 1.73911224 0.25078109 158.50 -2.51898113e-01 1.31243162e+00 1.33638670e+00 1.76042265 0.25950113 158.75 -2.82260633e-01 1.44577666e+00 1.47307203e+00 1.76360227 0.31307949 159.00 1.40681806e-01 1.70842258e+00 1.71420508e+00 1.48863568 0.36544384 159.25 3.35439174e-01 1.56810903e+00 1.60358516e+00 1.36005921 0.43732252 159.50 -1.54785650e-01 1.64746305e+00 1.65471844e+00 1.66447527 0.44012202 159.75 -1.95296238e-02 1.73407087e+00 1.73418084e+00 1.58205815 0.49733970 160.00 -7.19053668e-02 1.17655754e+00 1.17875274e+00 1.63183545 0.22011935 160.25 3.12532233e-01 1.37334858e+00 1.40846112e+00 1.34703756 0.25646826 160.50 -1.03323764e-01 1.11448255e+00 1.11926188e+00 1.66324215 0.19878847 160.75 -2.37038739e-01 1.12453163e+00 1.14924269e+00 1.77854394 0.23310400 161.00 6.86169581e-02 8.19595006e-01 8.22462315e-01 1.48727054 0.17648893 161.25 -3.68097691e-02 6.13413644e-01 6.14517093e-01 1.63073252 0.12601896 161.50 5.88290917e-02 4.23793964e-01 4.27857670e-01 1.43286249 0.07291060 161.75 -9.14720621e-03 2.49846395e-01 2.50013785e-01 1.60739130 0.02348128 162.00 -4.35685446e-01 5.77324392e-01 7.23273988e-01 2.21727518 0.13526701 162.25 -3.88940404e-01 4.01723037e-01 5.59156540e-01 2.34002893 0.07068488 162.50 -7.28450790e-02 2.35101529e-01 2.46128288e-01 1.87126076 0.01445974 162.75 2.86774432e-02 1.02718996e-01 1.06647024e-01 1.29854497 0.00218192 163.00 1.99653922e-01 2.39207065e-01 3.11579377e-01 0.87528213 0.01351167 163.25 3.51192071e-01 5.31606237e-02 3.55192796e-01 0.15023142 0.01532195 163.50 6.17690221e-02 -2.70684669e-01 2.77642940e-01 -1.34644246 0.01119923 163.75 -2.65232510e-02 2.14011771e-02 3.40806869e-02 2.46266845 0.00016094 164.00 7.14919174e-02 2.01275578e-01 2.13595300e-01 1.22950167 0.00979785 164.25 6.39663378e-02 -1.67045130e-01 1.78873608e-01 -1.20509284 0.00676288 164.50 2.07061991e-02 -4.44992536e-01 4.45474021e-01 -1.52429830 0.04588298 164.75 -2.08692350e-02 -3.00493839e-01 3.01217649e-01 -1.64013478 0.01245377 165.00 -1.14879540e-01 -8.39608604e-02 1.42291022e-01 -2.51045410 0.00232876 165.25 -5.16376837e-01 -1.95394397e-01 5.52108692e-01 -2.77984890 0.03008100 165.50 -4.97095550e-01 -1.87432653e-01 5.31257927e-01 -2.78102105 0.04476413 165.75 -4.53278154e-01 -1.26179592e-02 4.53453744e-01 -3.11376272 0.02498535 166.00 -1.45137496e-01 3.26067170e-02 1.48755137e-01 2.92060102 0.00296636 166.25 -1.07442930e-01 3.79351144e-01 3.94273096e-01 1.84679599 0.02060460 166.50 -2.19529581e-01 7.17550937e-02 2.30958937e-01 2.82568079 0.01041411 166.75 -2.84043101e-02 1.19326669e-01 1.22660747e-01 1.80448557 0.00286454 167.00 -4.26641182e-02 3.36161469e-01 3.38858023e-01 1.69703696 0.03818903 167.25 1.38373255e-02 1.08134368e-01 1.09016114e-01 1.44352383 0.00353460 167.50 2.86209784e-01 1.51493021e-01 3.23830474e-01 0.48681789 0.04905994 167.75 1.57230042e-01 -8.12440176e-02 1.76979876e-01 -0.47693452 0.01152982 168.00 2.85931385e-02 -1.55584458e-01 1.58190048e-01 -1.38904552 0.01476304 168.25 9.91762463e-02 -8.19634744e-02 1.28662112e-01 -0.69065781 0.00657384 168.50 1.77717262e-01 4.53499391e-02 1.83412220e-01 0.24984824 0.01567911 168.75 -4.26034975e-02 -1.14944243e-01 1.22585631e-01 -1.92574337 0.00515741 169.00 -3.32873246e-02 -2.06702647e-01 2.09365781e-01 -1.73046514 0.01491839 169.25 -3.46153662e-01 -7.55286357e-02 3.54297802e-01 -2.92676567 0.03398261 169.50 -4.80692243e-01 -1.89839579e-01 5.16821148e-01 -2.76546497 0.12369777 169.75 -3.02496599e-01 -1.90418420e-01 3.57440019e-01 -2.57977148 0.06573004 170.00 -3.72037533e-01 -6.15685265e-02 3.77097612e-01 -2.97758897 0.09209724 170.25 -2.24160190e-01 3.68852028e-02 2.27174622e-01 2.97850569 0.03643434 170.50 -4.11009568e-01 6.28966429e-02 4.15794243e-01 2.98974107 0.12279789 170.75 -5.81341679e-01 1.11324960e-02 5.81448261e-01 3.12244533 0.20965202 171.00 -6.60055178e-01 1.75305039e-01 6.82938280e-01 2.88199432 0.29118204 171.25 -8.97023184e-01 1.41924981e-01 9.08181310e-01 2.98467565 0.31824678 171.50 -9.83169197e-01 1.64874420e-01 9.96897810e-01 2.97544176 0.36640211 171.75 -1.24049779e+00 7.18313682e-01 1.43346061e+00 2.61671794 0.43182947 172.00 -1.07596296e+00 1.10847337e+00 1.54480080e+00 2.34131284 0.38571014 172.25 -5.54458323e-01 1.96961182e+00 2.04616586e+00 1.84520136 0.30668819 172.50 1.40276897e-01 2.11396323e+00 2.11861232e+00 1.50453617 0.32550102 172.75 1.03188813e+00 1.64041581e+00 1.93797759e+00 1.00929670 0.32140347 173.00 1.33963946e+00 1.22863313e+00 1.81773850e+00 0.74220287 0.33788661 173.25 1.32197253e+00 7.85887202e-01 1.53793045e+00 0.53635133 0.34479493 173.50 1.08442025e+00 6.66457812e-01 1.27284457e+00 0.55106770 0.34362817 173.75 8.26555160e-01 8.49700946e-01 1.18540505e+00 0.79920531 0.40759143 174.00 7.52217632e-01 7.54118452e-01 1.06514131e+00 0.78666005 0.38799943 174.25 5.89025634e-01 9.04394055e-01 1.07929598e+00 0.99351259 0.38252734 174.50 4.81223710e-01 9.79019206e-01 1.09089636e+00 1.11394238 0.35156479 174.75 6.83843314e-01 1.09103948e+00 1.28763692e+00 1.01091699 0.39596575 175.00 9.56853252e-01 1.02372392e+00 1.40127756e+00 0.81914856 0.36350297 175.25 7.62856864e-01 7.25849083e-01 1.05299928e+00 0.76054426 0.42388792 175.50 3.32657600e-01 6.64325382e-01 7.42959819e-01 1.10655291 0.19565093 175.75 -5.70938821e-01 4.37081600e-01 7.19035091e-01 2.48821428 0.13603135 176.00 6.79906041e-02 -4.33709314e-01 4.39006254e-01 -1.41529653 0.05470148 176.25 7.57959804e-01 -7.16354724e-01 1.04291282e+00 -0.75718570 0.41323072 176.50 9.01077623e-01 -5.27262302e-01 1.04400499e+00 -0.52942611 0.48258399 176.75 8.89350143e-01 -3.53793027e-01 9.57138017e-01 -0.37861765 0.52197896 177.00 8.22608700e-01 -2.71149461e-01 8.66144967e-01 -0.31840614 0.37264149 177.25 9.07180816e-01 -2.49633543e-01 9.40900600e-01 -0.26852896 0.48269711 177.50 9.44205580e-01 -1.91637930e-01 9.63456939e-01 -0.20024209 0.47574814 177.75 9.82741670e-01 -1.31547182e-01 9.91506859e-01 -0.13306635 0.55143743 178.00 8.81657743e-01 1.25769413e-01 8.90583135e-01 0.14169509 0.43254005 178.25 8.72088833e-01 2.85369989e-01 9.17591937e-01 0.31624376 0.54280654 178.50 9.83086902e-01 2.29312989e-01 1.00947724e+00 0.22916059 0.57597945 178.75 9.21227217e-01 2.57082068e-01 9.56426043e-01 0.27214126 0.59938716 179.00 8.98946926e-01 4.68389202e-01 1.01365380e+00 0.48033924 0.55436090 179.25 8.57418452e-01 6.13571529e-01 1.05434170e+00 0.62112144 0.59972149 179.50 7.31714962e-01 1.02367819e+00 1.25830196e+00 0.95021298 0.64271749 179.75 7.92157055e-01 1.16092032e+00 1.40543544e+00 0.97201267 0.74111684 180.00 8.30890174e-01 1.33500601e+00 1.57245653e+00 1.01407834 0.67982318 180.25 8.34337495e-01 1.51637761e+00 1.73075709e+00 1.06778615 0.70999445 180.50 1.07240082e+00 1.87044669e+00 2.15606454e+00 1.05021091 0.71849206 180.75 1.18703175e+00 2.12417013e+00 2.43333991e+00 1.06120567 0.75263738 181.00 1.58609952e+00 2.58084078e+00 3.02926572e+00 1.01973461 0.74331971 181.25 1.60932097e+00 2.86218740e+00 3.28360027e+00 1.05858190 0.73629219 181.50 2.06003157e+00 3.37544884e+00 3.95441335e+00 1.02283875 0.62124579 181.75 2.88834600e+00 3.33653701e+00 4.41305130e+00 0.85727404 0.67059151 182.00 4.14461941e+00 2.76084174e+00 4.97997160e+00 0.58762870 0.74181757 182.25 4.27887379e+00 2.21477657e+00 4.81809051e+00 0.47763407 0.72188813 182.50 3.16782901e+00 2.69989284e+00 4.16227847e+00 0.70581907 0.63322193 182.75 2.98439039e+00 2.97778298e+00 4.21589581e+00 0.78428994 0.64118330 183.00 2.46194857e+00 4.35564559e+00 5.00328285e+00 1.05633424 0.57677414 183.25 2.21896722e+00 4.46319032e+00 4.98436389e+00 1.10941476 0.52202813 183.50 1.22877403e-01 4.19779510e+00 4.19959315e+00 1.54153279 0.38168545 183.75 -1.24172973e+00 3.49174705e+00 3.70596684e+00 1.91246767 0.32317416 184.00 -2.31692503e+00 2.64072656e+00 3.51305826e+00 2.29097363 0.43247501 184.25 -2.28566484e+00 1.88595409e+00 2.96328983e+00 2.45171957 0.38000811 184.50 -2.57705064e+00 1.37492163e+00 2.92089019e+00 2.65148591 0.46963924 184.75 -2.51370151e+00 6.78109850e-01 2.60356068e+00 2.87809943 0.49225469 185.00 -2.31426955e+00 -8.99801377e-01 2.48303968e+00 -2.77077356 0.55759572 185.25 -1.87431267e+00 -1.13768657e+00 2.19257354e+00 -2.59605026 0.56184767 185.50 -1.66246629e+00 -1.67249461e+00 2.35818412e+00 -2.35318747 0.70741521 185.75 -1.51487617e+00 -1.86387570e+00 2.40184980e+00 -2.25326707 0.73020873 186.00 -1.52198313e+00 -2.25715092e+00 2.72234511e+00 -2.16406076 0.85243412 186.25 -1.49938186e+00 -2.14634655e+00 2.61819584e+00 -2.18056459 0.85502199 186.50 -1.33181765e+00 -2.00381074e+00 2.40603320e+00 -2.15739623 0.90259341 186.75 -1.27275710e+00 -1.84548275e+00 2.24181115e+00 -2.17454947 0.88092029 187.00 -1.04783678e+00 -1.66989984e+00 1.97142776e+00 -2.13118047 0.90416185 187.25 -7.67185460e-01 -1.59809363e+00 1.77270324e+00 -2.01836742 0.83049020 187.50 -3.77398455e-01 -1.60318580e+00 1.64700768e+00 -1.80199235 0.78581365 187.75 -1.63834158e-01 -1.69786658e+00 1.70575278e+00 -1.66699263 0.67221836 188.00 8.49842664e-02 -1.93567374e+00 1.93753843e+00 -1.52692027 0.74447732 188.25 3.03621182e-01 -2.07462299e+00 2.09672277e+00 -1.42547791 0.64025744 188.50 7.30280919e-01 -2.45663213e+00 2.56287956e+00 -1.28184679 0.67098793 188.75 6.61523520e-01 -3.17048185e+00 3.23876034e+00 -1.36509671 0.55426604 189.00 -2.55064118e-02 -4.03465622e+00 4.03473684e+00 -1.57711807 0.45892421 189.25 -2.01429193e+00 -2.91332149e+00 3.54186590e+00 -2.17573211 0.42060124 189.50 -3.32732434e+00 -2.35385004e+00 4.07574500e+00 -2.52589730 0.69252720 189.75 -2.23689269e+00 -1.29530406e+00 2.58486006e+00 -2.61670952 0.52968664 190.00 -2.00013511e+00 -9.66831318e-01 2.22155424e+00 -2.69132679 0.61153316 190.25 -1.89487340e+00 -8.41840223e-01 2.07346091e+00 -2.72351188 0.62169911 190.50 -1.76020375e+00 -7.60656488e-01 1.91752850e+00 -2.73368896 0.66119303 190.75 -1.41695418e+00 -1.01989665e+00 1.74583743e+00 -2.51771387 0.62462178 191.00 -1.32171933e+00 -1.03727556e+00 1.68014362e+00 -2.47619354 0.68830499 191.25 -1.27325524e+00 -1.11755991e+00 1.69414257e+00 -2.42122494 0.72032970 191.50 -1.26645463e+00 -1.04764133e+00 1.64361178e+00 -2.45047089 0.73793451 191.75 -1.08390977e+00 -1.10739005e+00 1.54957192e+00 -2.34547967 0.70504900 192.00 -1.04665937e+00 -1.12368275e+00 1.53562976e+00 -2.32072033 0.72025591 192.25 -1.23581474e+00 -1.15544722e+00 1.69183225e+00 -2.38979068 0.76689868 192.50 -1.23295858e+00 -1.13281452e+00 1.67435229e+00 -2.39849961 0.74282071 192.75 -1.12713447e+00 -1.33435631e+00 1.74669370e+00 -2.27220702 0.71039404 193.00 -1.17231714e+00 -1.33652354e+00 1.77781401e+00 -2.29083661 0.69808045 193.25 -1.61770564e+00 -1.14161217e+00 1.97996209e+00 -2.52705253 0.78107530 193.50 -1.65766170e+00 -9.88883561e-01 1.93021579e+00 -2.60371134 0.79298700 193.75 -1.59973559e+00 -8.43285632e-01 1.80839282e+00 -2.65646902 0.79861942 194.00 -1.55038296e+00 -7.51837672e-01 1.72306332e+00 -2.69006810 0.72746203 194.25 -1.60996436e+00 -4.61574509e-01 1.67482425e+00 -2.86238322 0.71050284 194.50 -1.61923140e+00 -3.84499519e-01 1.66425665e+00 -2.90845257 0.67842447 194.75 -1.41838245e+00 -2.05847288e-01 1.43324174e+00 -2.99747068 0.60883774 195.00 -1.33615064e+00 -2.79911090e-02 1.33644380e+00 -3.12064665 0.57674712 195.25 -1.14247168e+00 1.31138234e-01 1.14997338e+00 3.02730815 0.62491361 195.50 -1.09720179e+00 3.19306094e-01 1.14271963e+00 2.85839593 0.50594255 195.75 -9.44542399e-01 6.49488310e-01 1.14629639e+00 2.53922234 0.53138399 196.00 -6.43673730e-01 7.25457799e-01 9.69847869e-01 2.29653112 0.35484384 196.25 5.04942792e-01 6.56465482e-01 8.28199343e-01 0.91513004 0.14073066 196.50 9.60531850e-01 -2.43025133e-01 9.90798996e-01 -0.24781054 0.31891458 196.75 8.58966844e-01 -6.17428296e-01 1.05784769e+00 -0.62323455 0.72854512 197.00 7.97162856e-01 -5.10904578e-01 9.46832671e-01 -0.56995399 0.67594670 197.25 6.80378230e-01 -1.50697714e-01 6.96867518e-01 -0.21797211 0.50837460 197.50 2.80613389e-01 -3.44194979e-02 2.82716423e-01 -0.12204844 0.09032314 197.75 -1.63211411e-01 -3.47750774e-01 3.84146542e-01 -2.00961193 0.27296093 198.00 -1.09325547e-01 -6.37288588e-01 6.46597881e-01 -1.74069056 0.54561919 198.25 -6.59240299e-02 -8.40878419e-01 8.43458649e-01 -1.64903530 0.79554614 198.50 -5.88109412e-02 -9.41678576e-01 9.43513258e-01 -1.63316863 0.75855013 198.75 -6.03103765e-02 -1.05645526e+00 1.05817534e+00 -1.62782192 0.81882396 199.00 -1.48204256e-02 -1.11163150e+00 1.11173029e+00 -1.58412768 0.76893439 199.25 4.23458815e-02 -1.14000838e+00 1.14079458e+00 -1.53366816 0.79482605 199.50 -7.01731681e-02 -1.22423885e+00 1.22624836e+00 -1.62805351 0.69390908 199.75 -9.38742995e-02 -1.20635830e+00 1.21000526e+00 -1.64845609 0.67566526 200.00 3.38894697e-02 -7.84895532e-01 7.85626815e-01 -1.52764608 0.34522531 200.25 -1.81103227e-02 -8.48818551e-01 8.49011729e-01 -1.59212901 0.40960815 200.50 -2.24515016e-02 -1.10003935e+00 1.10026844e+00 -1.59120322 0.38881177 200.75 4.25232890e-02 -1.04286597e+00 1.04373256e+00 -1.53004349 0.37035138 201.00 2.32710882e-01 -1.38449823e+00 1.40391941e+00 -1.40426973 0.41926077 201.25 1.33478685e-01 -1.44630205e+00 1.45244834e+00 -1.47876739 0.39781229 201.50 -1.64941636e-01 -1.28331315e+00 1.29386954e+00 -1.69862349 0.32813505 201.75 -5.18012161e-02 -1.10514749e+00 1.10636086e+00 -1.61763472 0.27039846 202.00 -2.12973050e-01 -1.17816675e+00 1.19726121e+00 -1.74963159 0.26616112 202.25 -1.03457186e-01 -1.33319693e+00 1.33720508e+00 -1.64824195 0.32485654 202.50 -4.54630624e-01 -1.01501083e+00 1.11217624e+00 -1.99190849 0.19582523 202.75 -3.06189811e-01 -8.60520584e-01 9.13371708e-01 -1.91264592 0.11692877 203.00 -1.38039162e-01 -4.11890356e-02 1.44053278e-01 -2.85161670 0.00274999 203.25 -1.19802559e-01 1.18098091e-02 1.20383242e-01 3.04333284 0.00202034 203.50 1.38989532e-01 1.11527687e-01 1.78203578e-01 0.67621353 0.00427522 203.75 2.97576762e-01 5.41288474e-01 6.17693404e-01 1.06814022 0.04682093 204.00 7.68446852e-01 3.68294501e-01 8.52145178e-01 0.44692754 0.08052646 204.25 8.84237133e-01 4.55622151e-01 9.94719484e-01 0.47579000 0.07935187 204.50 2.30753768e-01 3.41420426e-01 4.12086410e-01 0.97645335 0.01187036 204.75 9.45677373e-02 2.45506376e-01 2.63090170e-01 1.20311799 0.00442678 205.00 1.90862817e-01 1.50064202e+00 1.51273100e+00 1.44428813 0.09363504 205.25 8.46177866e-02 1.49306850e+00 1.49546438e+00 1.51418314 0.08277238 205.50 1.81366471e-01 1.99548678e+00 2.00371188e+00 1.48015703 0.14265046 205.75 2.44025012e-01 1.51387663e+00 1.53341797e+00 1.41097890 0.08154799 206.00 -9.59011497e-02 1.23658606e+00 1.24029920e+00 1.64819456 0.06888327 206.25 -3.25833985e-01 1.29067536e+00 1.33116891e+00 1.81808172 0.07376237 206.50 -6.70227115e-01 1.60070589e+00 1.73535695e+00 1.96732488 0.12687567 206.75 -6.52712377e-01 1.08734295e+00 1.26820666e+00 2.11142314 0.05832724 207.00 -8.44080448e-01 7.15081261e-01 1.10626083e+00 2.43874272 0.05069119 207.25 -8.22443910e-01 1.10601561e+00 1.37829044e+00 2.21019507 0.05797598 207.50 -9.65621887e-01 1.92499753e+00 2.15361118e+00 2.03574102 0.18687078 207.75 -5.07778716e-01 1.35378645e+00 1.44588277e+00 1.92963745 0.11150565 208.00 -4.28115436e-01 1.46587407e+00 1.52711152e+00 1.85494803 0.26187193 208.25 -4.32530793e-01 1.15697397e+00 1.23518082e+00 1.92855542 0.17533234 208.50 -4.54781456e-01 1.04789379e+00 1.14232551e+00 1.98026172 0.26887921 208.75 -5.67638826e-01 7.60232244e-01 9.48771259e-01 2.21215963 0.14037155 209.00 -7.26439982e-01 4.31401883e-01 8.44880247e-01 2.60570189 0.15065159 209.25 -4.54224905e-01 4.17563370e-01 6.16992247e-01 2.39822298 0.06810021 209.50 -7.11622659e-01 1.94521649e-01 7.37729951e-01 2.87476161 0.13745559 209.75 -9.10857582e-01 -1.20845960e-01 9.18839094e-01 -3.00969024 0.16063033 210.00 -1.21546997e+00 -1.65237934e-01 1.22665024e+00 -3.00647525 0.29758932 210.25 -1.19445869e+00 -1.36958634e-01 1.20228501e+00 -3.02742955 0.29549160 210.50 -1.02275369e+00 -3.45496515e-01 1.07953367e+00 -2.81581844 0.32195153 210.75 -1.44099416e+00 -8.57659167e-01 1.67691485e+00 -2.60472058 0.50189391 211.00 -1.86896179e+00 -1.03695544e+00 2.13735695e+00 -2.63504901 0.64347956 211.25 -2.86792951e+00 -9.61962712e-01 3.02496148e+00 -2.81796471 0.73944391 211.50 -3.18954025e+00 -6.07314702e-01 3.24684434e+00 -2.95343673 0.74987946 211.75 -2.81570067e+00 5.89277610e-02 2.81631723e+00 3.12066743 0.59329605 212.00 -2.66063892e+00 2.38843420e-01 2.67133780e+00 3.05206343 0.54720469 212.25 -2.03523812e+00 5.63344677e-01 2.11176500e+00 2.87155798 0.36490683 212.50 -1.73074652e+00 8.50744937e-01 1.92853584e+00 2.68472950 0.34770483 212.75 -1.99133135e+00 3.79399391e-01 2.02715180e+00 2.95332357 0.37540636 213.00 -1.83540176e+00 4.73372483e-01 1.89546330e+00 2.88918120 0.40684642 213.25 -1.46924516e+00 -1.72462051e-02 1.46934638e+00 -3.12985505 0.25833901 213.50 -1.73223169e+00 -1.89344642e-01 1.74254929e+00 -3.03271813 0.27551109 213.75 -2.10186048e+00 -5.75665345e-01 2.17926779e+00 -2.87426455 0.36342465 214.00 -2.19661665e+00 -3.39942697e-01 2.22276534e+00 -2.98805326 0.35737996 214.25 -1.81027491e+00 -7.17890631e-01 1.94742451e+00 -2.76405148 0.37450249 214.50 -1.74773933e+00 -8.46447941e-01 1.94192350e+00 -2.69057551 0.35283947 214.75 -1.78396918e+00 -9.73290574e-01 2.03220092e+00 -2.64215242 0.34345234 215.00 -2.25851553e+00 -1.53655118e+00 2.73164454e+00 -2.54418574 0.39938714 215.25 -2.73533378e+00 -2.33263013e+00 3.59488723e+00 -2.43548852 0.39137598 215.50 -3.04888320e+00 -2.74969821e+00 4.10567035e+00 -2.40774502 0.38273453 215.75 -3.71428091e+00 -6.39273983e-01 3.76889293e+00 -2.97115010 0.15305592 216.00 -2.98536794e+00 2.60060292e+00 3.95923696e+00 2.42496646 0.13718215 216.25 -2.01812647e+00 4.20815213e+00 4.66705248e+00 2.01797120 0.26772885 216.50 -7.80617842e-01 3.34094705e+00 3.43093157e+00 1.80033013 0.21640941 216.75 -3.04729588e-01 3.14028032e+00 3.15503100e+00 1.66753242 0.39320005 217.00 -2.67930535e-01 2.35210162e+00 2.36731257e+00 1.68421856 0.32982431 217.25 -2.99121612e-01 1.64526264e+00 1.67223290e+00 1.75063980 0.29770995 217.50 -1.31726200e+00 1.22091257e+00 1.79605308e+00 2.39413640 0.32984214 217.75 -1.96706397e+00 1.30399050e+00 2.36002794e+00 2.55619387 0.59225331 218.00 -2.10527159e+00 1.31086696e+00 2.48002836e+00 2.58467830 0.54771882 218.25 -2.41171230e+00 1.66899692e+00 2.93290077e+00 2.53623022 0.68858625 218.50 -2.44207325e+00 1.70338845e+00 2.97745764e+00 2.53253485 0.56839304 218.75 -2.94029948e+00 1.71104834e+00 3.40191820e+00 2.61456593 0.68012150 219.00 -2.67877963e+00 2.01941271e+00 3.35468150e+00 2.49562860 0.58354484 219.25 -2.38563754e+00 2.05259126e+00 3.14712525e+00 2.43109447 0.58951891 219.50 -2.04142302e+00 2.03505833e+00 2.88251112e+00 2.35775581 0.41048523 219.75 -2.01652461e+00 2.59615735e+00 3.28730961e+00 2.23118904 0.43592955 220.00 -2.07559537e+00 2.53753003e+00 3.27828534e+00 2.25639232 0.44782457 220.25 -2.37629646e+00 2.30788210e+00 3.31256768e+00 2.37079886 0.62399403 220.50 -2.32782231e+00 2.69005003e+00 3.55740437e+00 2.28413198 0.66288897 220.75 -2.61123005e+00 2.95371577e+00 3.94245599e+00 2.29472861 0.75769001 221.00 -2.80833841e+00 3.14287650e+00 4.21478793e+00 2.30004018 0.70658375 221.25 -2.55948266e+00 3.70395548e+00 4.50224807e+00 2.17546548 0.72459308 221.50 -2.08369745e+00 3.68227521e+00 4.23095093e+00 2.08574382 0.66345910 221.75 -1.94799981e+00 3.76703757e+00 4.24090501e+00 2.04804371 0.72764365 222.00 -1.32099127e+00 4.87173269e+00 5.04765266e+00 1.83558372 0.78825786 222.25 -1.12171024e+00 4.88559146e+00 5.01270763e+00 1.79648059 0.78868456 222.50 -3.82037138e-01 5.42891836e+00 5.44234388e+00 1.64105128 0.79854055 222.75 4.02324616e-01 5.12889590e+00 5.14465142e+00 1.49251389 0.76379494 223.00 1.82950838e+00 3.69271646e+00 4.12107459e+00 1.11080577 0.67111454 223.25 1.98899428e+00 2.87731165e+00 3.49785943e+00 0.96595465 0.61167649 223.50 1.51122023e+00 1.23624093e+00 1.95245442e+00 0.68564548 0.33858000 223.75 1.02032983e+00 1.17382362e+00 1.55529253e+00 0.85524019 0.24625861 224.00 5.71791487e-01 6.05432454e-01 8.32762847e-01 0.81396691 0.06097075 224.25 1.54736339e-01 4.13034126e-01 4.41067482e-01 1.21234718 0.01803792 224.50 -1.00239157e+00 1.26893174e+00 1.61708893e+00 2.23937859 0.19218821 224.75 -9.33546758e-01 1.26274463e+00 1.57036096e+00 2.20741401 0.15970706 225.00 -9.52803229e-01 1.59490882e+00 1.85783965e+00 2.10930404 0.23938641 225.25 -8.66317433e-01 1.56681889e+00 1.79037072e+00 2.07587467 0.23542942 225.50 -1.84840890e-01 1.83147336e+00 1.84077723e+00 1.67138043 0.30526080 225.75 -3.83892049e-01 1.59090481e+00 1.63656690e+00 1.80757413 0.27190157 226.00 -6.94763994e-01 1.27198230e+00 1.44935709e+00 2.07072179 0.27920004 226.25 -8.70623780e-01 1.29780090e+00 1.56277732e+00 2.16168633 0.24824568 226.50 -1.08593411e+00 1.21872883e+00 1.63234581e+00 2.29863811 0.18758261 226.75 -1.30609488e+00 1.44418833e+00 1.94719382e+00 2.30602599 0.21182258 227.00 -1.81887909e+00 1.62078528e+00 2.43624015e+00 2.41372197 0.39612281 227.25 -1.76236884e+00 1.72761504e+00 2.46791362e+00 2.36615232 0.30132666 227.50 -1.84358017e+00 2.13180696e+00 2.81840181e+00 2.28381831 0.40608833 227.75 -1.69178865e+00 2.47475021e+00 2.99775540e+00 2.17044418 0.41550327 228.00 -1.52351793e+00 3.13196015e+00 3.48285533e+00 2.02353908 0.53654346 228.25 -1.45865341e+00 3.31188881e+00 3.61887790e+00 1.98566295 0.44894197 228.50 -1.82468005e+00 3.61071516e+00 4.04558046e+00 2.03871590 0.51441847 228.75 -1.04897140e+00 3.22407945e+00 3.39043202e+00 1.88534957 0.36281575 229.00 -8.58760958e-01 3.46830681e+00 3.57304108e+00 1.81351712 0.53519067 229.25 -1.73814739e-02 3.43106716e+00 3.43111118e+00 1.57586219 0.44584862 229.50 4.90541315e-01 3.39722440e+00 3.43245748e+00 1.42739276 0.53188419 229.75 2.13114554e-01 3.13348457e+00 3.14072338e+00 1.50288890 0.38490295 230.00 2.38859506e-02 2.91284486e+00 2.91294279e+00 1.56259630 0.45865450 230.25 -7.47831566e-02 3.05005959e+00 3.05097624e+00 1.59531000 0.42674443 230.50 1.83153974e-01 3.07031282e+00 3.07577083e+00 1.51121374 0.44346282 230.75 -2.87813068e-02 2.60662334e+00 2.60678223e+00 1.58183748 0.30218176 231.00 -1.12518800e-01 2.57766813e+00 2.58012277e+00 1.61442002 0.37234552 231.25 -1.61991144e-01 2.11286794e+00 2.11906867e+00 1.64731548 0.23885505 231.50 -1.26630463e-01 1.93877746e+00 1.94290847e+00 1.63601828 0.28978657 231.75 2.11694491e-01 2.48767647e+00 2.49666753e+00 1.48590357 0.36643010 232.00 4.12116848e-02 2.55776818e+00 2.55810017e+00 1.55468536 0.41009805 232.25 -2.47220417e-01 2.69631325e+00 2.70762315e+00 1.66222900 0.33021021 232.50 -3.29894231e-01 2.47203804e+00 2.49395315e+00 1.70346279 0.32560450 232.75 -2.52863615e-01 2.78075850e+00 2.79223169e+00 1.66148025 0.32592568 233.00 -3.02947348e-02 2.95855447e+00 2.95870957e+00 1.58103568 0.38211746 233.25 4.52621062e-01 2.60655061e+00 2.64555701e+00 1.39886325 0.32259203 233.50 3.32556515e-01 2.52222885e+00 2.54405821e+00 1.43970225 0.31826527 233.75 1.11576476e-01 2.56422703e+00 2.56665338e+00 1.52731104 0.30696711 234.00 3.94567168e-02 2.49409329e+00 2.49440538e+00 1.55497758 0.29212564 234.25 1.28598965e-01 2.09221034e+00 2.09615882e+00 1.50940796 0.21596391 234.50 -4.38353443e-02 2.47128355e+00 2.47167230e+00 1.58853235 0.26067647 234.75 -1.46987790e-01 2.58900557e+00 2.59317474e+00 1.62750929 0.25947286 235.00 1.52430254e-01 2.44380071e+00 2.44854996e+00 1.50850277 0.25391916 235.25 1.21486034e-02 2.42054815e+00 2.42057864e+00 1.56577742 0.29620144 235.50 3.89418081e-01 2.38830907e+00 2.41984848e+00 1.40916687 0.26872226 235.75 2.56299646e-01 2.42213736e+00 2.43565985e+00 1.46537314 0.25798300 236.00 -5.56940170e-02 2.73827238e+00 2.73883871e+00 1.59113263 0.25807277 236.25 8.16194500e-02 3.05910569e+00 3.06019433e+00 1.54412183 0.42569244 236.50 -1.24222291e-01 3.20033397e+00 3.20274393e+00 1.60959227 0.44756144 236.75 4.95208230e-01 2.77787372e+00 2.82166859e+00 1.39438076 0.38319288 237.00 1.14227610e+00 2.33787913e+00 2.60201336e+00 1.11631426 0.28671046 237.25 7.24214630e-01 1.84394310e+00 1.98106360e+00 1.19655272 0.24133222 237.50 5.88372284e-01 1.89495567e+00 1.98419730e+00 1.26974007 0.23445315 237.75 2.34287353e-02 1.92708885e+00 1.92723126e+00 1.55863935 0.23806536 238.00 1.24896462e-01 1.77096819e+00 1.77536685e+00 1.50038851 0.16649000 238.25 2.86032454e-02 1.67279940e+00 1.67304392e+00 1.55369896 0.21110378 238.50 -3.76079202e-01 1.65726277e+00 1.69939855e+00 1.79394504 0.16453896 238.75 -8.81417743e-01 1.85769063e+00 2.05618864e+00 2.01381182 0.31216588 239.00 -6.35250707e-01 2.28426554e+00 2.37095182e+00 1.84204085 0.32633797 239.25 -8.10386808e-01 2.20672279e+00 2.35081948e+00 1.92274239 0.37456987 239.50 -8.12233382e-01 1.90457396e+00 2.07053738e+00 1.97390685 0.25310349 239.75 -9.79210633e-01 1.73993858e+00 1.99655697e+00 2.08340195 0.25517469 240.00 -9.22502008e-01 2.29929242e+00 2.47744942e+00 1.95234646 0.30213491 240.25 -9.53767833e-01 2.86890977e+00 3.02329561e+00 1.89175129 0.49350387 240.50 -7.07254803e-01 3.05445902e+00 3.13527180e+00 1.79833473 0.35143072 240.75 -3.81951399e-01 3.90141602e+00 3.92006809e+00 1.66838605 0.52579065 241.00 5.89090209e-01 3.43833090e+00 3.48843040e+00 1.40111354 0.53561831 241.25 9.68015407e-01 3.13575641e+00 3.28177118e+00 1.27137496 0.55748483 241.50 7.23128611e-01 2.55514390e+00 2.65549907e+00 1.29499960 0.30741614 241.75 7.01936968e-01 1.47126995e+00 1.63013826e+00 1.12563925 0.19464519 242.00 8.22520308e-01 1.65460485e+00 1.84777078e+00 1.10946354 0.24199825 242.25 3.42835671e-01 1.63360576e+00 1.66919264e+00 1.36393402 0.25042288 242.50 -3.63898457e-01 1.04070030e+00 1.10248773e+00 1.90717438 0.12258616 242.75 -7.24997257e-01 7.32444079e-01 1.03058010e+00 2.35108502 0.13803599 243.00 -1.60696458e+00 4.49722015e-01 1.66870760e+00 2.86871556 0.23981630 243.25 -2.17151293e+00 4.70867101e-01 2.22197755e+00 2.92806011 0.29948236 243.50 -2.68874039e+00 1.88466100e+00 3.28348473e+00 2.53023228 0.25192776 243.75 -1.72280373e+00 2.74625129e+00 3.24190513e+00 2.13106885 0.12357510 244.00 2.90028452e+00 3.09747285e+00 4.24334636e+00 0.81826334 0.20117035 244.25 3.62010402e+00 2.47226623e+00 4.38374879e+00 0.59917534 0.25662596 244.50 2.95957841e+00 1.15322132e+00 3.17632237e+00 0.37155858 0.23582376 244.75 2.29218124e+00 1.34402876e+00 2.65716167e+00 0.53032496 0.20545006 245.00 1.41014603e+00 1.53690989e+00 2.08581011e+00 0.82838539 0.16195672 245.25 9.38496019e-01 1.25201305e+00 1.56470810e+00 0.92755789 0.10519071 245.50 9.74166793e-01 8.33107346e-01 1.28182245e+00 0.70750514 0.08997144 245.75 6.90023165e-01 1.11131762e+00 1.30811269e+00 1.01514683 0.09331559 246.00 -4.03245852e-02 1.61023563e+00 1.61074047e+00 1.59583375 0.14152076 246.25 1.51098093e-01 1.59570973e+00 1.60284752e+00 1.47638761 0.10846246 246.50 -2.84599622e-01 2.10166929e+00 2.12085142e+00 1.70539357 0.20934987 246.75 -2.23605675e-03 2.16283612e+00 2.16283727e+00 1.57183018 0.20162320 247.00 3.53231119e-01 2.00140939e+00 2.03234145e+00 1.39610415 0.27280868 247.25 2.53496439e-01 1.81852440e+00 1.83610769e+00 1.43229206 0.22490407 247.50 1.34327657e-01 1.71609134e+00 1.72134058e+00 1.49268025 0.19941787 247.75 2.78128113e-01 1.54700832e+00 1.57181105e+00 1.39291214 0.17260540 248.00 2.18566230e-01 1.94906108e+00 1.96127772e+00 1.45912363 0.37318056 248.25 -4.72232961e-03 1.50465615e+00 1.50466357e+00 1.57393479 0.22042372 248.50 -3.36279793e-01 1.01159943e+00 1.06602885e+00 1.89172814 0.17877859 248.75 -6.84363010e-01 9.50263181e-01 1.17104775e+00 2.19493963 0.14366462 249.00 -1.04514174e+00 8.98468620e-01 1.37824785e+00 2.43151599 0.20821651 249.25 -1.45093928e+00 1.02710663e+00 1.77768749e+00 2.52559043 0.21183053 249.50 -2.33395030e+00 1.23595097e+00 2.64100337e+00 2.65458292 0.30309987 249.75 -2.53050728e+00 9.75502781e-01 2.71202374e+00 2.77365110 0.15454578 250.00 -2.00597224e+00 5.84232825e-01 2.08931870e+00 2.85818562 0.07861191 250.25 -1.23966849e+00 1.83322656e+00 2.21302905e+00 2.16538516 0.04451443 250.50 1.44311345e+00 5.89931436e+00 6.07325994e+00 1.33088386 0.23772475 250.75 2.76663699e+00 5.50391764e+00 6.16014526e+00 1.10501751 0.32702011 251.00 2.63289469e+00 5.12893815e+00 5.76525290e+00 1.09653290 0.39484647 251.25 2.46951844e+00 3.44634171e+00 4.23978684e+00 0.94904101 0.29597728 251.50 1.97439816e+00 3.56229273e+00 4.07285865e+00 1.06469657 0.39114850 251.75 1.36995239e+00 4.20377141e+00 4.42136445e+00 1.25576282 0.41793068 252.00 1.40008884e+00 4.42298761e+00 4.63929609e+00 1.26422767 0.51217474 252.25 1.11366664e+00 4.13787870e+00 4.28512468e+00 1.30788669 0.51526388 252.50 1.14954060e+00 4.11007481e+00 4.26780488e+00 1.29807651 0.62688197 252.75 1.37384397e+00 4.00623216e+00 4.23525009e+00 1.24043673 0.53352566 253.00 1.53423288e+00 3.62422485e+00 3.93559097e+00 1.17034343 0.52783772 253.25 1.46749564e+00 4.46351578e+00 4.69856537e+00 1.25315321 0.60709645 253.50 1.35540491e+00 4.59469882e+00 4.79044672e+00 1.28393923 0.65073390 253.75 2.08996351e+00 4.17665598e+00 4.67037500e+00 1.10683550 0.54653995 254.00 2.61962020e+00 4.20924029e+00 4.95783358e+00 1.01410498 0.54100123 254.25 2.35190959e+00 4.06595393e+00 4.69717575e+00 1.04638079 0.48972646 254.50 2.43714600e+00 3.54581877e+00 4.30261681e+00 0.96862474 0.50802599 254.75 1.93261080e+00 3.38260175e+00 3.89576425e+00 1.05171807 0.52276978 255.00 1.63210460e+00 3.46933900e+00 3.83406814e+00 1.13107776 0.50443263 255.25 1.81729725e+00 3.27762160e+00 3.74771566e+00 1.06453837 0.52149421 255.50 2.02722640e+00 3.34264732e+00 3.90933984e+00 1.02563063 0.55361026 255.75 2.78205008e+00 2.87546739e+00 4.00101429e+00 0.80190873 0.52689493 256.00 2.66553848e+00 2.60047562e+00 3.72391848e+00 0.77304355 0.48569346 256.25 2.28864164e+00 1.43343950e+00 2.70048687e+00 0.55955345 0.38587640 256.50 2.35488832e+00 1.27970855e+00 2.68014048e+00 0.49778232 0.34318065 256.75 2.03949530e+00 1.26553016e+00 2.40023076e+00 0.55536507 0.29828627 257.00 1.84444168e+00 1.05783173e+00 2.12625800e+00 0.52072439 0.23164703 257.25 1.40034065e+00 1.23472534e+00 1.86694954e+00 0.72263019 0.21814477 257.50 1.20017700e+00 1.29305442e+00 1.76420367e+00 0.82263277 0.20613244 257.75 5.31377926e-01 1.00084121e+00 1.13315737e+00 1.08271096 0.10898879 258.00 3.52829714e-01 1.18101589e+00 1.23259374e+00 1.28048577 0.10951744 258.25 1.26100578e-01 9.31311521e-01 9.39809824e-01 1.43621373 0.07723871 258.50 -1.37599473e-01 1.30349719e+00 1.31073969e+00 1.67596860 0.11768746 258.75 -2.37057620e-01 1.57379482e+00 1.59154844e+00 1.72030043 0.22332659 259.00 -7.15876265e-01 1.61474183e+00 1.76631537e+00 1.98809626 0.19758477 259.25 -1.10178095e+00 1.84488685e+00 2.14884358e+00 2.10916026 0.27278529 259.50 -1.28338219e+00 1.84186150e+00 2.24488834e+00 2.17936158 0.26832523 259.75 -1.56385004e+00 1.62826697e+00 2.25762713e+00 2.33601723 0.34164476 260.00 -2.28140659e+00 1.44378403e+00 2.69987562e+00 2.57736959 0.40788327 260.25 -2.93604184e+00 1.48566504e+00 3.29052310e+00 2.67314902 0.58273687 260.50 -3.02579166e+00 1.96687698e+00 3.60888074e+00 2.56519132 0.57239578 260.75 -3.36077142e+00 2.50705526e+00 4.19286425e+00 2.50067180 0.70095796 261.00 -3.61223372e+00 2.91019638e+00 4.63869329e+00 2.46341602 0.65480739 261.25 -3.83438330e+00 3.47757590e+00 5.17648814e+00 2.40495360 0.74999929 261.50 -3.71888622e+00 3.36622561e+00 5.01613293e+00 2.40592833 0.66375563 261.75 -3.69528414e+00 3.21142407e+00 4.89575014e+00 2.42613675 0.65850744 262.00 -3.98511155e+00 2.51806364e+00 4.71399603e+00 2.57806994 0.48502492 262.25 -4.04356060e+00 1.47811665e+00 4.30525390e+00 2.79113406 0.39383212 262.50 -4.21872453e+00 -3.34253349e-03 4.21872586e+00 -3.14080034 0.26553140 262.75 -4.52305668e+00 -1.63942282e+00 4.81100290e+00 -2.79386186 0.33426085 263.00 -2.79298626e+00 -2.41686474e+00 3.69350882e+00 -2.42826375 0.18202285 263.25 -1.59262640e+00 -3.66566682e+00 3.99669515e+00 -1.98066168 0.21910928 263.50 1.67502282e+00 -4.01666090e+00 4.35192672e+00 -1.17570526 0.21201415 263.75 2.20419369e+00 -4.39707568e+00 4.91861204e+00 -1.10612023 0.31830146 264.00 1.58470635e+00 -2.76953702e+00 3.19086658e+00 -1.05107505 0.14972081 264.25 1.59451783e+00 -1.83497620e+00 2.43097198e+00 -0.85539843 0.09325174 264.50 3.26156287e+00 2.28397569e+00 3.98175053e+00 0.61090737 0.22378682 264.75 3.56477371e+00 3.01094228e+00 4.66619599e+00 0.70137273 0.29135506 265.00 3.54915464e+00 2.27801452e+00 4.21732721e+00 0.57062244 0.28732652 265.25 3.90965587e+00 2.12023704e+00 4.44756272e+00 0.49691835 0.35083960 265.50 3.67839750e+00 8.12133466e-01 3.76698406e+00 0.21729855 0.40074922 265.75 3.44184420e+00 6.36131025e-01 3.50013631e+00 0.18276035 0.32873013 266.00 3.47562887e+00 1.22915572e+00 3.68657292e+00 0.33992267 0.33314459 266.25 3.59901028e+00 8.21395254e-01 3.69155321e+00 0.22438486 0.40197900 266.50 3.08341242e+00 4.98657491e-01 3.12347425e+00 0.16033442 0.39327197 266.75 3.20035266e+00 7.75104817e-01 3.29287787e+00 0.23761804 0.38475993 267.00 3.02856067e+00 7.42285489e-01 3.11819940e+00 0.24035702 0.35912421 267.25 3.13947864e+00 8.02280265e-01 3.24036723e+00 0.25019130 0.31322333 267.50 2.49435565e+00 1.77238238e+00 3.05992637e+00 0.61777625 0.38930454 267.75 2.27595099e+00 1.62898475e+00 2.79884694e+00 0.62121051 0.34296812 268.00 2.28330204e+00 1.73378009e+00 2.86696034e+00 0.64944571 0.33787848 268.25 1.99101462e+00 2.05052476e+00 2.85810969e+00 0.80012172 0.25935526 268.50 1.65727502e+00 1.55633940e+00 2.27348913e+00 0.75399973 0.26177832 268.75 1.57566929e+00 1.69415276e+00 2.31363075e+00 0.82161777 0.25377879 269.00 1.40303873e+00 2.11997136e+00 2.54220304e+00 0.98615685 0.33556548 269.25 1.28954311e+00 2.50790337e+00 2.82001787e+00 1.09585992 0.30987113 269.50 1.04555392e+00 2.59929233e+00 2.80169656e+00 1.18835558 0.29904818 269.75 1.14209850e+00 2.40741217e+00 2.66458671e+00 1.12783014 0.20397120 270.00 1.54730806e+00 2.24974474e+00 2.73047864e+00 0.96832532 0.20742767 270.25 9.48599302e-01 2.20963768e+00 2.40464952e+00 1.16528848 0.11744775 270.50 -4.49833268e-01 2.59448736e+00 2.63319476e+00 1.74247009 0.17333357 270.75 -6.59280535e-01 3.10268885e+00 3.17195979e+00 1.78016912 0.13452313 271.00 -8.07770653e-01 4.22450765e+00 4.30104154e+00 1.75972644 0.22950460 271.25 -5.89997091e-01 4.86906600e+00 4.90468147e+00 1.69138099 0.19727009 271.50 -1.63809290e+00 5.96617779e+00 6.18697226e+00 1.83875641 0.30315460 271.75 2.89269416e-01 5.25908175e+00 5.26703120e+00 1.51584791 0.16380492 272.00 1.03676414e+00 6.69685506e+00 6.77663247e+00 1.41720207 0.27013852 272.25 -2.85917166e-02 6.70695623e+00 6.70701718e+00 1.57505930 0.20643304 272.50 -3.89130918e-01 7.38556890e+00 7.39581306e+00 1.62343566 0.23178529 272.75 -1.42974627e+00 9.05166052e+00 9.16388196e+00 1.72745606 0.23812609 273.00 -3.32342338e+00 8.74666637e+00 9.35677912e+00 1.93391238 0.21732829 273.25 4.30853026e-01 6.15923190e+00 6.17428311e+00 1.50095770 0.08227295 273.50 1.30107507e+00 4.64629913e+00 4.82502766e+00 1.29776541 0.04263494 273.75 2.48148023e+00 -1.55511797e+00 2.92850406e+00 -0.55981342 0.01792036 274.00 2.55961806e+00 -5.61175131e+00 6.16793299e+00 -1.14286673 0.07530372 274.25 3.01295978e+00 -6.87992986e+00 7.51074973e+00 -1.15802111 0.15132866 274.50 3.26032719e+00 -8.60629105e+00 9.20315049e+00 -1.20867148 0.26982958 274.75 3.24736506e+00 -8.81404536e+00 9.39323030e+00 -1.21779743 0.35352408 275.00 3.57041257e+00 -7.83462147e+00 8.60982807e+00 -1.14319385 0.38437712 275.25 2.62334925e+00 -6.83419438e+00 7.32039440e+00 -1.20428384 0.43413246 275.50 2.37104669e+00 -6.00210963e+00 6.45346283e+00 -1.19457696 0.48040920 275.75 2.79571426e+00 -5.32176166e+00 6.01141959e+00 -1.08708577 0.58545885 276.00 2.79103649e+00 -4.79403590e+00 5.54731150e+00 -1.04357587 0.58420328 276.25 2.99125560e+00 -4.49686205e+00 5.40086829e+00 -0.98381859 0.56783971 276.50 2.35140890e+00 -3.86763743e+00 4.52633882e+00 -1.02453687 0.50133462 276.75 2.71839580e+00 -3.21067772e+00 4.20691420e+00 -0.86823663 0.53064804 277.00 2.78432191e+00 -2.92971497e+00 4.04174199e+00 -0.81083757 0.47479299 277.25 3.46601742e+00 -3.35104344e+00 4.82107549e+00 -0.76853414 0.64208939 277.50 3.30999197e+00 -3.45017195e+00 4.78118534e+00 -0.80613137 0.60582966 277.75 2.48118388e+00 -3.02869927e+00 3.91526407e+00 -0.88444271 0.59465999 278.00 2.31612811e+00 -2.97689763e+00 3.77178590e+00 -0.90959342 0.59055198 278.25 2.12900917e+00 -2.52841435e+00 3.30538336e+00 -0.87094554 0.56506661 278.50 2.15217198e+00 -2.47316731e+00 3.27847538e+00 -0.85468637 0.52597808 278.75 2.64068558e+00 -2.20592536e+00 3.44083232e+00 -0.69593365 0.62848744 279.00 2.56364506e+00 -2.03702497e+00 3.27440784e+00 -0.67142824 0.58011039 279.25 2.45185555e+00 -1.76467015e+00 3.02087014e+00 -0.62384418 0.60935321 279.50 2.50349222e+00 -1.87670686e+00 3.12881798e+00 -0.64326784 0.55377749 279.75 2.70502038e+00 -1.63451139e+00 3.16050040e+00 -0.54353940 0.65866713 280.00 2.89129583e+00 -1.67641750e+00 3.34215008e+00 -0.52544556 0.62679961 280.25 2.96640656e+00 -2.14875604e+00 3.66288417e+00 -0.62689073 0.71016211 280.50 2.65608804e+00 -2.04862373e+00 3.35434984e+00 -0.65699032 0.59044851 280.75 2.04855341e+00 -2.05663867e+00 2.90281479e+00 -0.78736768 0.50121147 281.00 1.39797300e+00 -2.04950061e+00 2.48088317e+00 -0.97218220 0.29902285 281.25 4.97451959e-01 -1.56490821e+00 1.64207069e+00 -1.26301826 0.16042028 281.50 4.07642962e-01 -1.36825167e+00 1.42768534e+00 -1.28123987 0.10596427 281.75 -7.98363940e-02 -1.37433479e+00 1.37665172e+00 -1.62882205 0.11883064 282.00 2.97923954e-01 -8.19281964e-01 8.71769246e-01 -1.22202183 0.03730529 282.25 6.68745771e-01 -7.51594043e-01 1.00603902e+00 -0.84366204 0.06140840 282.50 7.00825576e-01 2.96591020e-02 7.01452886e-01 0.04229500 0.02766740 282.75 5.79184275e-01 5.48303015e-01 7.97552895e-01 0.75801556 0.05747117 283.00 5.57405457e-01 5.91497022e-01 8.12754311e-01 0.81506262 0.07218025 283.25 6.91013697e-01 7.28894570e-01 1.00438400e+00 0.81207023 0.14241701 283.50 1.01125595e+00 3.97351416e-01 1.08652048e+00 0.37439554 0.13024505 283.75 1.02418160e+00 3.26447518e-01 1.07494927e+00 0.30855945 0.17763376 284.00 1.43858397e+00 2.77371854e-01 1.46507986e+00 0.19047162 0.25681162 284.25 1.59609888e+00 2.85794719e-01 1.62148397e+00 0.17718062 0.29527135 284.50 1.33366120e+00 2.38598068e-01 1.35483624e+00 0.17703167 0.20306789 284.75 1.36899965e+00 1.23642055e-01 1.37457172e+00 0.09007125 0.23093469 285.00 1.39068405e+00 -7.39482988e-02 1.39264872e+00 -0.05312402 0.19425817 285.25 1.42756127e+00 -3.47089211e-02 1.42798316e+00 -0.02430865 0.23379803 285.50 1.02402272e+00 2.58582678e-02 1.02434915e+00 0.02524629 0.14778948 285.75 1.14294557e+00 -8.93322547e-02 1.14643135e+00 -0.07800110 0.19036289 286.00 1.18000360e+00 1.36411181e-01 1.18786215e+00 0.11509147 0.22855603 286.25 1.14343207e+00 1.10424437e-01 1.14875170e+00 0.09627425 0.22461440 286.50 3.90906091e-01 1.48802483e-01 4.18269950e-01 0.36372399 0.02582302 286.75 1.71368639e-01 3.05673453e-01 3.50433261e-01 1.05983120 0.01610330 287.00 -1.20514898e-01 6.03491734e-01 6.15407275e-01 1.76789958 0.04410871 287.25 1.37531288e-01 1.12958443e+00 1.13792611e+00 1.44963878 0.12214530 287.50 2.80479342e-01 2.00202707e+00 2.02157885e+00 1.43160459 0.29260581 287.75 8.05968072e-01 2.13602690e+00 2.28302331e+00 1.20999225 0.34712720 288.00 1.30834200e+00 1.89925286e+00 2.30627843e+00 0.96757797 0.51120202 288.25 1.62253094e+00 1.71360539e+00 2.35988349e+00 0.81269076 0.47651200 288.50 1.85201200e+00 1.29398016e+00 2.25927712e+00 0.60984546 0.47489499 288.75 2.16179585e+00 1.45418216e+00 2.60538040e+00 0.59214946 0.48070417 289.00 1.84252392e+00 6.61027461e-01 1.95751161e+00 0.34445913 0.35988763 289.25 1.92756479e+00 5.44758034e-01 2.00306449e+00 0.27543161 0.36260086 289.50 1.82913608e+00 3.98699975e-01 1.87208453e+00 0.21461486 0.42065273 289.75 1.75419926e+00 4.53024346e-01 1.81175222e+00 0.25272945 0.35617065 290.00 1.62711680e+00 3.75308857e-01 1.66984006e+00 0.22669403 0.35375056 290.25 1.60932041e+00 1.16305758e-01 1.61351765e+00 0.07214468 0.32341056 290.50 1.69766676e+00 -1.45774459e-01 1.70391391e+00 -0.08565742 0.44692979 290.75 1.55860688e+00 1.05950041e-01 1.56220384e+00 0.06787298 0.30753817 291.00 1.34669561e+00 2.22076926e-01 1.36488360e+00 0.16343420 0.25615135 291.25 1.29279313e+00 -1.87078118e-01 1.30625889e+00 -0.14371088 0.22666794 291.50 1.38223179e+00 -2.59692281e-01 1.40641559e+00 -0.18571402 0.36951790 291.75 1.34417412e+00 -5.01603658e-01 1.43471610e+00 -0.35716415 0.29021760 292.00 1.35517743e+00 -8.83490951e-01 1.61773364e+00 -0.57773604 0.38654814 292.25 1.63616044e+00 -7.67972521e-01 1.80742988e+00 -0.43884870 0.31759579 292.50 2.09456810e+00 -1.22701617e+00 2.42750576e+00 -0.52991935 0.45071827 292.75 2.56666688e+00 -2.41491715e+00 3.52414581e+00 -0.75494544 0.49088603 293.00 2.87894173e+00 -4.03264179e+00 4.95484665e+00 -0.95079593 0.64209255 293.25 1.51335694e+00 -7.16055184e+00 7.31872611e+00 -1.36251494 0.67822253 293.50 -1.17918085e+00 -8.72731262e+00 8.80661416e+00 -1.70509687 0.75526802 293.75 -4.23013165e+00 -9.18446132e+00 1.01117923e+01 -2.00240940 0.73558594 294.00 -7.09294735e+00 -9.51356201e+00 1.18666661e+01 -2.21145086 0.79142885 294.25 -1.25932955e+01 -6.63694617e+00 1.42351729e+01 -2.65656172 0.76928921 294.50 -1.59024611e+01 -4.73989868e+00 1.65938214e+01 -2.85191598 0.84042826 294.75 -1.78367036e+01 2.84048740e+00 1.80614608e+01 2.98366917 0.80243810 295.00 -1.89221373e+01 8.06964527e+00 2.05710101e+01 2.73848108 0.84212041 295.25 -1.40395984e+01 1.39388147e+01 1.97838540e+01 2.35979667 0.80893377 295.50 -9.49212975e+00 1.50349928e+01 1.77806506e+01 2.13393878 0.83567792 295.75 -4.42273944e+00 1.47976666e+01 1.54444670e+01 1.86122608 0.83066774 296.00 -1.98639151e+00 1.42186840e+01 1.43567659e+01 1.70960088 0.83663363 296.25 2.36439682e+00 1.19370906e+01 1.21689976e+01 1.37525583 0.74797831 296.50 3.51206854e+00 9.56960342e+00 1.01937204e+01 1.21905552 0.69619176 296.75 3.17017623e+00 6.51813536e+00 7.24817949e+00 1.11811816 0.74605990 297.00 2.68643271e+00 5.65552937e+00 6.26114472e+00 1.12733987 0.72836967 297.25 1.63940302e+00 5.10907974e+00 5.36566287e+00 1.26029506 0.77254351 297.50 1.55423361e+00 4.83793707e+00 5.08146408e+00 1.25995123 0.73150556 297.75 2.97394434e-01 3.74510142e+00 3.75689075e+00 1.49155370 0.67882833 298.00 8.04112006e-02 3.97256710e+00 3.97338085e+00 1.55055747 0.71995351 298.25 -1.34332578e-01 3.95873134e+00 3.96100985e+00 1.60471655 0.73271021 298.50 -3.74519845e-01 3.87022006e+00 3.88829891e+00 1.66726560 0.70377806 298.75 -1.02306303e+00 3.73830778e+00 3.87577128e+00 1.83792571 0.75112979 299.00 -1.41736207e+00 3.73020736e+00 3.99040877e+00 1.93391599 0.73097972 299.25 -1.86866200e+00 3.82499748e+00 4.25705337e+00 2.02523350 0.81064724 299.50 -2.01572256e+00 3.88155395e+00 4.37373965e+00 2.04977086 0.76926692 299.75 -2.65181989e+00 3.40845736e+00 4.31853335e+00 2.23198527 0.74567065 300.00 -2.96934358e+00 3.83567015e+00 4.85070786e+00 2.22956854 0.74912070 300.25 -3.06354139e+00 4.74032177e+00 5.64410634e+00 2.14454696 0.78665838 300.50 -2.99289342e+00 4.72455807e+00 5.59275066e+00 2.13546743 0.70521824 300.75 -3.17492363e+00 5.15286962e+00 6.05245450e+00 2.12300388 0.78153853 301.00 -2.95137153e+00 5.22369774e+00 5.99980099e+00 2.08508030 0.75463231 301.25 -2.93335373e+00 5.04309844e+00 5.83415855e+00 2.09761916 0.78845621 301.50 -3.01126670e+00 4.91135034e+00 5.76099725e+00 2.12080997 0.77518587 301.75 -3.35870022e+00 4.89685107e+00 5.93801462e+00 2.17198946 0.82603603 302.00 -3.62898501e+00 4.63502423e+00 5.88667834e+00 2.23505315 0.75184569 302.25 -3.65167190e+00 4.59912288e+00 5.87253258e+00 2.24186379 0.77806031 302.50 -3.50615880e+00 4.08044959e+00 5.37989018e+00 2.28064062 0.65879128 302.75 -3.31305751e+00 3.87953530e+00 5.10168052e+00 2.27759823 0.71784263 303.00 -3.90212342e+00 3.86293948e+00 5.49079854e+00 2.36124063 0.61777867 303.25 -4.15348230e+00 4.00375548e+00 5.76900973e+00 2.37454752 0.69357108 303.50 -4.39364185e+00 3.52903937e+00 5.63544209e+00 2.46489437 0.64497225 303.75 -4.46917219e+00 3.06615357e+00 5.41985220e+00 2.54027872 0.69869300 304.00 -5.15557216e+00 3.25810096e+00 6.09878235e+00 2.57800604 0.66715240 304.25 -5.48596225e+00 3.01114490e+00 6.25801689e+00 2.63960834 0.66487885 304.50 -4.61302765e+00 2.37025117e+00 5.18633925e+00 2.66695279 0.58334409 304.75 -4.27556655e+00 1.99796429e+00 4.71935702e+00 2.70444708 0.59753407 305.00 -4.19436466e+00 1.22318444e+00 4.36908172e+00 2.85783632 0.52394428 305.25 -4.22436915e+00 8.45603514e-01 4.30817130e+00 2.94403101 0.56621067 305.50 -4.40307758e+00 -1.97457932e-01 4.40750290e+00 -3.09677724 0.57056760 305.75 -4.59689550e+00 -1.14468316e+00 4.73727219e+00 -2.89754388 0.60457031 306.00 -4.17815550e+00 -2.57581989e+00 4.90834305e+00 -2.58913131 0.57869658 306.25 -4.17775134e+00 -3.66062701e+00 5.55461937e+00 -2.42207241 0.63751366 306.50 -3.72560012e+00 -4.34173443e+00 5.72107980e+00 -2.27996850 0.63488075 306.75 -3.85215627e+00 -5.14419718e+00 6.42665330e+00 -2.21355159 0.66609537 307.00 -3.32350493e+00 -6.87872960e+00 7.63954226e+00 -2.02087880 0.68336668 307.25 -3.09239572e+00 -7.93253219e+00 8.51398721e+00 -1.94251104 0.65937362 307.50 -7.45088440e-01 -9.73172824e+00 9.76020959e+00 -1.64721006 0.61703820 307.75 1.14412357e-01 -1.04801720e+01 1.04807965e+01 -1.55987973 0.61489951 308.00 5.63785506e+00 -9.86353719e+00 1.13611080e+01 -1.05153190 0.42897989 308.25 1.02592150e+01 -6.63350651e+00 1.22169923e+01 -0.57397434 0.31305933 308.50 7.03865004e+00 8.44976149e+00 1.09973207e+01 0.87625489 0.20975207 308.75 3.75392620e+00 9.87896871e+00 1.05681590e+01 1.20765656 0.23304998 309.00 -1.38506030e+00 9.71172479e+00 9.80999442e+00 1.71245836 0.32454186 309.25 -2.71716253e+00 7.67981093e+00 8.14631623e+00 1.91085768 0.31625899 309.50 -1.98218691e+00 5.45071810e+00 5.79994765e+00 1.91958477 0.28524575 309.75 -8.20107543e-01 3.18841719e+00 3.29219996e+00 1.82255362 0.12293630 310.00 -9.05066167e-01 1.93471434e+00 2.13594578e+00 2.00835662 0.06774788 310.25 -8.09447130e-01 -4.80667960e-02 8.10873031e-01 -3.08228005 0.00991789 310.50 -9.98539562e-01 -7.94409684e-01 1.27599687e+00 -2.46955781 0.03161963 310.75 -5.82185861e-01 -1.23823009e-01 5.95207959e-01 -2.93202893 0.00839262 311.00 3.59618054e-01 -4.33542439e-01 5.63279852e-01 -0.87833199 0.01233944 311.25 1.69420894e+00 -1.13190792e+00 2.03753760e+00 -0.58899708 0.12762719 311.50 3.10983105e+00 -2.48954944e+00 3.98357949e+00 -0.67507116 0.46723658 311.75 3.84057068e+00 -4.21438982e+00 5.70184748e+00 -0.83177345 0.54417620 312.00 5.19888387e+00 -5.71943529e+00 7.72918712e+00 -0.83303897 0.70664944 312.25 5.62659426e+00 -7.28321285e+00 9.20346415e+00 -0.91302318 0.72966527 312.50 5.47817534e+00 -9.38093723e+00 1.08633507e+01 -1.04224782 0.82027536 312.75 4.51586792e+00 -1.09639291e+01 1.18575210e+01 -1.18008721 0.82760332 313.00 3.65573464e+00 -1.11574801e+01 1.17411140e+01 -1.25417057 0.87855193 313.25 3.93075106e+00 -1.09144619e+01 1.16007018e+01 -1.22511546 0.87929162 313.50 4.74273485e+00 -1.06576595e+01 1.16653007e+01 -1.15210219 0.91786680 313.75 6.19609690e+00 -1.09586737e+01 1.25890486e+01 -1.05620229 0.90473406 314.00 7.89683959e+00 -1.15079917e+01 1.39568602e+01 -0.96938898 0.90366693 314.25 1.16976714e+01 -1.15497794e+01 1.64387627e+01 -0.77903660 0.81446348 314.50 1.72366889e+01 -1.24194584e+01 2.12449145e+01 -0.62436846 0.78205978 314.75 2.63287092e+01 -1.38380615e+01 2.97437872e+01 -0.48390807 0.51532647 315.00 2.20473956e+01 -5.28463889e+00 2.26719003e+01 -0.23525607 0.11805041 315.25 -1.84607927e+01 1.86154570e+01 2.62170957e+01 2.35202299 0.25689299 315.50 -1.98777923e+01 1.79631230e+01 2.67917975e+01 2.40674924 0.56985879 315.75 -1.17601674e+01 1.01145920e+01 1.55114960e+01 2.43128019 0.55879750 316.00 -9.25341115e+00 9.47490447e+00 1.32438451e+01 2.34436839 0.66577078 316.25 -7.73998855e+00 8.42168447e+00 1.14381901e+01 2.31403969 0.77754401 316.50 -6.22890419e+00 7.40451686e+00 9.67605898e+00 2.27017706 0.77117419 316.75 -2.35556766e+00 5.13846988e+00 5.65266059e+00 2.00062866 0.66144670 317.00 -1.14654230e+00 4.19015965e+00 4.34419120e+00 1.83788595 0.58059589 317.25 -6.91455954e-01 1.89306406e+00 2.01539149e+00 1.92099844 0.32958724 317.50 -3.86859429e-01 1.30071776e+00 1.35702871e+00 1.85988444 0.22457926 317.75 4.75990338e-02 1.17501044e+00 1.17597415e+00 1.53030901 0.14149855 318.00 3.40431966e-01 8.05989711e-01 8.74936190e-01 1.17114901 0.06921655 318.25 3.45993578e-01 1.53137357e-01 3.78368347e-01 0.41668452 0.01624698 318.50 1.17752416e-01 -8.95831711e-02 1.47955317e-01 -0.65036193 0.00198498 318.75 1.46259170e+00 7.06426286e-02 1.46429671e+00 0.04826212 0.14006110 319.00 1.51055584e+00 3.81574336e-01 1.55800446e+00 0.24742916 0.12208356 319.25 3.53378494e-01 4.29793869e-01 5.56416328e-01 0.88266188 0.02570131 319.50 7.60421537e-01 4.05544397e-01 8.61804602e-01 0.48994324 0.04692160 319.75 1.59730311e+00 1.12654437e+00 1.95460468e+00 0.61426015 0.18923745 320.00 1.48918636e+00 1.77482024e+00 2.31682172e+00 0.87268600 0.19956326 320.25 2.32247093e+00 3.34381655e+00 4.07123818e+00 0.96373279 0.47242314 320.50 2.92107329e+00 4.05679454e+00 4.99902502e+00 0.94674386 0.46120558 320.75 3.92086566e+00 4.13032349e+00 5.69497670e+00 0.81140806 0.44992084 321.00 5.83043162e+00 3.37570541e+00 6.73715963e+00 0.52482048 0.49878237 321.25 7.15585522e+00 2.08407122e+00 7.45316153e+00 0.28340084 0.64652513 321.50 7.47325401e+00 2.31428562e+00 7.82339078e+00 0.30030983 0.65414684 321.75 7.57898030e+00 2.81940941e+00 8.08640908e+00 0.35614127 0.78570549 322.00 8.04387447e+00 3.47130749e+00 8.76092987e+00 0.40740267 0.77644646 322.25 8.62467759e+00 3.85154066e+00 9.44560369e+00 0.41999966 0.83265282 322.50 9.99248977e+00 3.61261544e+00 1.06254808e+01 0.34691209 0.80900315 322.75 1.11513360e+01 2.75893339e+00 1.14875589e+01 0.24253796 0.86326399 323.00 1.15562287e+01 2.52610313e+00 1.18291005e+01 0.21520724 0.84719392 323.25 1.15885954e+01 1.79380030e+00 1.17266050e+01 0.15357136 0.89162103 323.50 1.30309191e+01 9.45911633e-01 1.30652057e+01 0.07246269 0.84716097 323.75 1.34664645e+01 3.23732387e-02 1.34665035e+01 0.00240398 0.87454373 324.00 1.30059130e+01 -6.48364546e-01 1.30220639e+01 -0.04981029 0.87064740 324.25 1.28226123e+01 4.59884106e-02 1.28226948e+01 0.00358649 0.89238181 324.50 1.39410952e+01 6.21423795e-01 1.39549383e+01 0.04454548 0.88851425 324.75 1.49070124e+01 4.91212410e-01 1.49151033e+01 0.03293985 0.91069202 325.00 1.57686303e+01 4.57817289e-01 1.57752749e+01 0.02902527 0.85959503 325.25 1.74640990e+01 2.56309985e-01 1.74659798e+01 0.01467534 0.91749586 325.50 1.84340828e+01 -1.01750305e+00 1.84621430e+01 -0.05514088 0.91095492 325.75 1.93347216e+01 -8.59143364e-01 1.93538004e+01 -0.04440605 0.92457009 326.00 2.16289204e+01 -1.33293981e+00 2.16699545e+01 -0.06154982 0.88677129 326.25 2.26977743e+01 -2.02393114e+00 2.27878313e+01 -0.08893350 0.90473642 326.50 2.60893194e+01 -4.62184445e+00 2.64955474e+01 -0.17533553 0.90701074 326.75 2.75228252e+01 -6.38716490e+00 2.82542348e+01 -0.22803153 0.91045816 327.00 2.88607972e+01 -1.20261605e+01 3.12661822e+01 -0.39481557 0.89921931 327.25 2.93553219e+01 -1.50931120e+01 3.30081346e+01 -0.47490540 0.90763581 327.50 2.86861294e+01 -1.88037437e+01 3.42997783e+01 -0.58023160 0.90670466 327.75 2.80721705e+01 -2.21067221e+01 3.57316935e+01 -0.66706992 0.89836352 328.00 2.58944470e+01 -3.17237948e+01 4.09502325e+01 -0.88622699 0.91154506 328.25 2.19751937e+01 -3.41850614e+01 4.06389907e+01 -0.99947783 0.89830499 328.50 1.02740738e+01 -3.66646304e+01 3.80769184e+01 -1.29758588 0.89766860 328.75 5.06363221e+00 -3.69172744e+01 3.72629242e+01 -1.43448531 0.89024083 329.00 -3.48344420e+00 -3.30825003e+01 3.32653906e+01 -1.67570543 0.82669288 329.25 -4.84791571e+00 -2.55281544e+01 2.59843983e+01 -1.75846626 0.72065637 329.50 -7.11765320e+00 -1.94845186e+01 2.07438533e+01 -1.92103401 0.70202800 329.75 -6.30506312e+00 -1.52955973e+01 1.65441566e+01 -1.96178768 0.64177117 330.00 -5.31632087e+00 -1.22684553e+01 1.33707989e+01 -1.97970349 0.64709536 330.25 -2.62795379e+00 -1.16279369e+01 1.19212020e+01 -1.79306566 0.57631114 330.50 -1.18973121e+00 -1.04868799e+01 1.05541513e+01 -1.68376282 0.57293711 330.75 -2.05794340e-01 -1.12296087e+01 1.12314942e+01 -1.58912032 0.56832456 331.00 -4.04478885e-01 -1.39661005e+01 1.39719565e+01 -1.59974971 0.73878230 331.25 -1.57329968e+00 -1.31251379e+01 1.32190967e+01 -1.69009630 0.64965576 331.50 -3.32208055e+00 -1.07785009e+01 1.12788431e+01 -1.86977140 0.64779935 331.75 -3.66911185e+00 -9.89498064e+00 1.05533418e+01 -1.92588444 0.52964096 332.00 -6.64320082e+00 -7.36062131e+00 9.91518346e+00 -2.30500890 0.54382655 332.25 -6.24970619e+00 -4.58944856e+00 7.75382909e+00 -2.50818542 0.38025100 332.50 -6.02689087e+00 -2.90449336e+00 6.69025376e+00 -2.69251148 0.33525320 332.75 -4.51000613e+00 -5.66809464e-01 4.54548438e+00 -3.01656995 0.12705213 333.00 -4.23680614e+00 2.04960627e+00 4.70652867e+00 2.69101954 0.18341795 333.25 -3.65837070e+00 3.62567967e+00 5.15065328e+00 2.36068249 0.15168523 333.50 -3.84723761e+00 5.80612926e+00 6.96508250e+00 2.15598979 0.28795282 333.75 -1.49430990e+00 1.01855908e+01 1.02946210e+01 1.71646539 0.34442636 334.00 9.76951342e-01 1.37999961e+01 1.38345338e+01 1.50012064 0.55492239 334.25 8.47999379e+00 1.74198828e+01 1.93742770e+01 1.11776461 0.60203816 334.50 1.38717148e+01 1.96411661e+01 2.40457871e+01 0.95588324 0.77069132 334.75 1.91545444e+01 2.00243279e+01 2.77104724e+01 0.80759484 0.78925493 335.00 2.28913593e+01 2.06801714e+01 3.08493731e+01 0.73469321 0.85504038 335.25 2.83597621e+01 1.94841591e+01 3.44079724e+01 0.60197176 0.86705298 335.50 3.39341346e+01 1.93936484e+01 3.90850238e+01 0.51920641 0.87838344 335.75 4.42473047e+01 1.49727575e+01 4.67119625e+01 0.32629285 0.89160258 336.00 5.09677708e+01 1.10960419e+01 5.21616316e+01 0.21436214 0.92570563 336.25 5.73585822e+01 -1.93511386e+00 5.73912156e+01 -0.03372434 0.94551816 336.50 6.05853333e+01 -1.02368062e+01 6.14440787e+01 -0.16738414 0.95884709 336.75 5.73074149e+01 -1.70093149e+01 5.97783957e+01 -0.28852604 0.96101499 337.00 5.46016143e+01 -2.05999095e+01 5.83583118e+01 -0.36076507 0.95921091 337.25 5.84339455e+01 -2.35121149e+01 6.29868680e+01 -0.38254852 0.95465509 337.50 6.09498665e+01 -2.88416167e+01 6.74294081e+01 -0.44198055 0.95746883 337.75 6.44751000e+01 -4.39227095e+01 7.80143764e+01 -0.59802083 0.95967931 338.00 6.32768312e+01 -5.32104770e+01 8.26759471e+01 -0.69919643 0.96231698 338.25 5.30608633e+01 -7.10429989e+01 8.86710939e+01 -0.92929259 0.96433282 338.50 4.36709833e+01 -7.82025864e+01 8.95700804e+01 -1.06150094 0.97109897 338.75 3.05378836e+01 -8.48986559e+01 9.02238555e+01 -1.22550805 0.97655552 339.00 2.22583344e+01 -8.89026886e+01 9.16467211e+01 -1.32547191 0.96891997 339.25 4.47806424e+00 -9.22056870e+01 9.23143639e+01 -1.52226843 0.95766411 339.50 -9.18555480e+00 -9.06120221e+01 9.10764128e+01 -1.67182357 0.94006519 339.75 -3.11069292e+01 -8.62651288e+01 9.17023091e+01 -1.91688013 0.96157428 340.00 -3.95822396e+01 -8.15252308e+01 9.06262487e+01 -2.02279407 0.95973469 340.25 -5.49707962e+01 -6.63705117e+01 8.61790767e+01 -2.26252191 0.93929522 340.50 -6.11480844e+01 -5.40566328e+01 8.16162225e+01 -2.41767214 0.89828289 340.75 -6.39166892e+01 -1.92694522e+01 6.67581826e+01 -2.84878078 0.83913581 341.00 -5.88409929e+01 -6.31736498e+00 5.91791479e+01 -3.03463901 0.82603054 341.25 -4.59549658e+01 6.23235389e+00 4.63756522e+01 3.00679632 0.79601245 341.50 -3.42647184e+01 9.34007118e+00 3.55148962e+01 2.87547241 0.70187202 341.75 -1.84469147e+01 1.10023621e+01 2.14788415e+01 2.60379954 0.65412190 342.00 -1.40040970e+01 9.14760840e+00 1.67270282e+01 2.56296454 0.45412324 342.25 -5.65474237e+00 4.30252568e+00 7.10547947e+00 2.49117076 0.16348574 342.50 -2.26257652e+00 4.65792521e-01 2.31002493e+00 2.93856103 0.02111321 342.75 -1.20351299e+00 -3.27261267e+00 3.48689507e+00 -1.92319834 0.09352512 343.00 -2.45873083e-01 -5.85039395e+00 5.85555830e+00 -1.61279837 0.19162268 343.25 1.30331370e+00 -7.22009227e+00 7.33678124e+00 -1.39220745 0.36837854 343.50 2.22273950e+00 -9.81151089e+00 1.00601350e+01 -1.34801271 0.46933130 343.75 4.73286044e+00 -1.43431120e+01 1.51038018e+01 -1.25207181 0.72020954 344.00 4.02871396e+00 -1.84720769e+01 1.89062995e+01 -1.35606141 0.75415831 344.25 2.14372188e+00 -2.24009056e+01 2.25032468e+01 -1.47538887 0.83463453 344.50 -1.68165131e+00 -2.84323166e+01 2.84820045e+01 -1.62987327 0.82548449 344.75 -6.73453045e+00 -3.48257830e+01 3.54709608e+01 -1.76181628 0.86918638 345.00 -1.53318713e+01 -4.52446579e+01 4.77718050e+01 -1.89751789 0.79427813 345.25 -3.21255495e+01 -5.19613977e+01 6.10904067e+01 -2.12453276 0.82411133 345.50 -7.01985431e+01 -4.10604609e+01 8.13252538e+01 -2.61233594 0.62482860 345.75 -9.55105487e+01 -7.24154326e+00 9.57846797e+01 -3.06591814 0.50972192 346.00 -3.60379768e+01 4.22339157e+01 5.55197209e+01 2.27720003 0.17495530 346.25 1.16953980e+01 4.10295141e+01 4.26638414e+01 1.29311239 0.18828529 346.50 1.35789071e+01 2.69165542e+00 1.38431112e+01 0.19568659 0.08500069 346.75 5.08904527e+00 -2.62479263e+00 5.72607353e+00 -0.47618631 0.03751858 347.00 -5.82816068e+00 9.38230572e-01 5.90319689e+00 2.98197978 0.06060843 347.25 -8.21183374e+00 4.78596194e+00 9.50471699e+00 2.61390666 0.19170710 347.50 -1.50346186e+01 1.15559821e+01 1.89626074e+01 2.48627778 0.50360119 347.75 -1.64429411e+01 1.39282384e+01 2.15491563e+01 2.43880503 0.66147821 348.00 -1.75865267e+01 2.41379291e+01 2.98651225e+01 2.20045020 0.81222057 348.25 -1.87326986e+01 2.77535696e+01 3.34839457e+01 2.16452221 0.87899138 348.50 -1.55008529e+01 3.48900713e+01 3.81784431e+01 1.98888074 0.91855953 348.75 -1.29310019e+01 3.89529129e+01 4.10431509e+01 1.89131483 0.93073482 349.00 -7.94618594e+00 4.76058050e+01 4.82644232e+01 1.73618790 0.93417010 349.25 -2.26710447e+00 5.10113363e+01 5.10616901e+01 1.61521025 0.93907048 349.50 5.99866488e+00 5.34082252e+01 5.37440461e+01 1.45894784 0.95619728 349.75 9.25916856e+00 5.38816826e+01 5.46714543e+01 1.40061587 0.95065831 350.00 1.85096923e+01 5.29787789e+01 5.61191564e+01 1.23467452 0.93484340 350.25 2.26477708e+01 5.09830607e+01 5.57870415e+01 1.15275820 0.95127273 350.50 2.83624280e+01 5.07884471e+01 5.81712445e+01 1.06149446 0.97205786 350.75 3.07953722e+01 4.94633641e+01 5.82664511e+01 1.01393227 0.96871131 351.00 3.35965268e+01 4.71613234e+01 5.79043784e+01 0.95181348 0.97139125 351.25 3.50197402e+01 4.57230977e+01 5.75932624e+01 0.91719085 0.97438587 351.50 3.71263602e+01 4.45175755e+01 5.79670696e+01 0.87568193 0.98820987 351.75 3.87195415e+01 4.30525269e+01 5.79027026e+01 0.83833723 0.98467340 352.00 4.13816690e+01 4.01560977e+01 5.76624203e+01 0.77036858 0.98295010 352.25 4.10188504e+01 3.74810501e+01 5.55641540e+01 0.74036106 0.98007841 352.50 4.00902206e+01 3.44813028e+01 5.28789753e+01 0.71032425 0.98594236 352.75 3.86249256e+01 3.33047431e+01 5.10008901e+01 0.71156893 0.98481445 353.00 3.64713378e+01 3.30926388e+01 4.92471443e+01 0.73686664 0.98538198 353.25 3.48212187e+01 3.33414962e+01 4.82096737e+01 0.76369289 0.98330204 353.50 3.35377061e+01 3.34137443e+01 4.73419057e+01 0.78354665 0.98721127 353.75 3.13588313e+01 3.46706019e+01 4.67485501e+01 0.83551214 0.97489723 354.00 2.92718223e+01 3.91314442e+01 4.88682874e+01 0.92855183 0.97977812 354.25 2.94861099e+01 4.45898803e+01 5.34573485e+01 0.98653670 0.96809736 354.50 3.14883165e+01 5.09869997e+01 5.99265235e+01 1.01755388 0.97111459 354.75 3.60535364e+01 5.19686936e+01 6.32503170e+01 0.96427401 0.93814372 355.00 4.45376334e+01 4.95300941e+01 6.66095414e+01 0.83842146 0.92038118 355.25 5.61351881e+01 4.14309935e+01 6.97688080e+01 0.63581396 0.88898493 355.50 6.27849359e+01 3.58789289e+01 7.23135238e+01 0.51916800 0.92718998 355.75 5.86619935e+01 2.80152406e+01 6.50083317e+01 0.44554359 0.89717892 356.00 5.73474113e+01 2.17320406e+01 6.13270508e+01 0.36223282 0.89568820 356.25 5.64549497e+01 1.37804219e+01 5.81124890e+01 0.23941419 0.89400803 356.50 5.39716381e+01 1.02677549e+01 5.49396443e+01 0.18799698 0.90611836 356.75 4.47930055e+01 3.71439905e+00 4.49467474e+01 0.08273435 0.90543433 357.00 3.92374380e+01 1.54613083e-01 3.92377426e+01 0.00394043 0.92412142 357.25 3.33547010e+01 3.88081977e-01 3.33569586e+01 0.01163448 0.91276738 357.50 2.99149453e+01 7.74060165e-01 2.99249582e+01 0.02586959 0.90387854 357.75 2.10281806e+01 1.90670174e+00 2.11144475e+01 0.09042636 0.84241809 358.00 1.66252039e+01 2.34756380e+00 1.67901299e+01 0.14027769 0.80649300 358.25 8.03118004e+00 5.57883778e+00 9.77871585e+00 0.60712453 0.56036979 358.50 3.30725607e+00 8.50575542e+00 9.12610639e+00 1.19995995 0.48820516 358.75 -4.08027094e+00 1.66914245e+01 1.71829061e+01 1.81054763 0.68717840 359.00 -6.15373373e+00 2.19895537e+01 2.28343800e+01 1.84366412 0.77143703 359.25 -7.97621982e+00 3.26477820e+01 3.36080013e+01 1.81041373 0.88872067 359.50 -7.75019236e+00 3.60744634e+01 3.68975933e+01 1.78241835 0.92147678 359.75 -7.70103136e+00 4.20438927e+01 4.27433597e+01 1.75195466 0.93905285 360.00 -8.83392362e+00 4.49602850e+01 4.58199239e+01 1.76480771 0.94270674 360.25 -1.33372293e+01 4.61397708e+01 4.80287428e+01 1.85218780 0.94676463 360.50 -1.65325067e+01 4.92711023e+01 5.19708120e+01 1.89453304 0.94122687 360.75 -3.02057975e+01 5.35021294e+01 6.14399548e+01 2.08475828 0.86290254 361.00 -4.13241945e+01 5.02450366e+01 6.50557665e+01 2.25907913 0.71924119 361.25 -6.03460796e+01 1.75775234e+01 6.28539470e+01 2.85815620 0.23120180 361.50 -1.97124274e+01 -4.20939331e+01 4.64809531e+01 -2.00876074 0.10840355 361.75 3.92901445e+01 -6.05905672e+01 7.22144881e+01 -0.99550929 0.56525882 362.00 3.76065065e+01 -4.00722236e+01 5.49548218e+01 -0.81713001 0.61415607 362.25 3.99310144e+01 -1.24793758e+01 4.18356395e+01 -0.30290617 0.80288067 362.50 3.25502916e+01 -4.59357451e+00 3.28728217e+01 -0.14019657 0.77105146 362.75 2.47724368e+01 5.64844486e+00 2.54082379e+01 0.22418068 0.75770488 363.00 2.33706932e+01 1.72467632e+01 2.90454840e+01 0.63575438 0.70579388 363.25 3.11791806e+01 2.95054116e+01 4.29268053e+01 0.75782371 0.91914062 363.50 3.52594025e+01 3.16830110e+01 4.74029392e+01 0.73202401 0.89892494 363.75 3.94329653e+01 3.61736543e+01 5.35116064e+01 0.74231603 0.91079749 364.00 4.50851298e+01 3.93125051e+01 5.98175726e+01 0.71710658 0.90118908 364.25 5.40622528e+01 4.55328082e+01 7.06821321e+01 0.69996538 0.92354516 364.50 6.56974179e+01 4.49446122e+01 7.96000559e+01 0.59998538 0.91065752 364.75 8.11019733e+01 3.41088304e+01 8.79826254e+01 0.39811005 0.92909633 365.00 8.73501297e+01 2.32163383e+01 9.03827612e+01 0.25977891 0.94435237 365.25 8.92342169e+01 1.62527659e+01 9.07022484e+01 0.18016116 0.95890631 365.50 9.42751933e+01 1.02428670e+01 9.48299973e+01 0.10822408 0.94743810 365.75 1.01592061e+02 -1.20978811e+00 1.01599264e+02 -0.01190773 0.94762323 366.00 9.77777379e+01 -2.90339984e+01 1.01997348e+02 -0.28864594 0.90532443 366.25 9.69290843e+01 -4.68247932e+01 1.07646684e+02 -0.45002265 0.94019007 366.50 7.59225707e+01 -6.40834108e+01 9.93525052e+01 -0.70103705 0.91132617 366.75 6.11918533e+01 -6.93863714e+01 9.25143851e+01 -0.84807160 0.93589513 367.00 3.93387308e+01 -6.84121433e+01 7.89161397e+01 -1.04894284 0.89038065 367.25 2.44266970e+01 -6.19958724e+01 6.66344635e+01 -1.19546853 0.89370062 367.50 1.59759353e+01 -4.85432710e+01 5.11045954e+01 -1.25285419 0.85305930 367.75 9.36300972e+00 -4.21222596e+01 4.31503268e+01 -1.35207065 0.84605909 368.00 7.93812318e+00 -3.53050080e+01 3.61864254e+01 -1.34963027 0.77361548 368.25 6.56033875e+00 -3.25885864e+01 3.32423526e+01 -1.37214352 0.79989039 368.50 4.02392435e+00 -2.43380552e+01 2.46684595e+01 -1.40694392 0.58800567 368.75 5.27022580e+00 -2.15828667e+01 2.22170073e+01 -1.33129746 0.46903145 369.00 9.94582888e+00 -1.17127542e+01 1.53658102e+01 -0.86679873 0.29049386 369.25 1.57415375e+01 -1.01355299e+01 1.87223120e+01 -0.57205501 0.40664442 369.50 2.72628062e+01 -9.10455123e+00 2.87428853e+01 -0.32230998 0.69070295 369.75 3.27985383e+01 -1.30221736e+01 3.52891076e+01 -0.37794789 0.74627809 370.00 3.73838210e+01 -2.45514914e+01 4.47250020e+01 -0.58109954 0.72981713 370.25 3.34352520e+01 -3.44927815e+01 4.80381936e+01 -0.80096529 0.72849619 370.50 3.30485054e+01 -6.21153245e+01 7.03599123e+01 -1.08183808 0.87949815 370.75 2.90711350e+01 -6.84390168e+01 7.43574469e+01 -1.16911687 0.86516923 371.00 5.31719954e+00 -7.32913028e+01 7.34839280e+01 -1.49837436 0.87955398 371.25 -2.26530722e+00 -7.10591539e+01 7.10952528e+01 -1.60266471 0.87186536 371.50 -1.77616956e+01 -6.71522508e+01 6.94615190e+01 -1.82937377 0.84309062 371.75 -3.18668784e+01 -5.90226317e+01 6.70758451e+01 -2.06585950 0.82970204 372.00 -5.22392322e+01 -4.69009810e+01 7.02042691e+01 -2.40998801 0.87371235 372.25 -5.04630243e+01 -3.12611328e+01 5.93613953e+01 -2.58696835 0.79517907 372.50 -3.34484560e+01 -2.14508148e+00 3.35171685e+01 -3.07754940 0.52638131 372.75 -1.33927115e+01 8.94561479e-01 1.34225542e+01 3.07489707 0.16072477 373.00 1.34746132e+01 -6.20772329e+00 1.48358022e+01 -0.43171444 0.28421714 373.25 1.54421266e+01 -2.14895433e+01 2.64624214e+01 -0.94770386 0.59292753 373.50 8.90977013e+00 -3.70446102e+01 3.81010124e+01 -1.33476482 0.81003369 373.75 -3.59750970e+00 -4.34517372e+01 4.36004076e+01 -1.65340116 0.82407840 374.00 -1.60803517e+01 -5.12532952e+01 5.37166452e+01 -1.87481301 0.91707306 374.25 -2.36115210e+01 -4.75863565e+01 5.31221729e+01 -2.03138534 0.90946421 374.50 -3.28132926e+01 -4.39029457e+01 5.48104079e+01 -2.21263473 0.92482181 374.75 -3.70512272e+01 -3.95010534e+01 5.41583480e+01 -2.32420341 0.92310282 375.00 -4.09146350e+01 -3.68099007e+01 5.50361349e+01 -2.40895678 0.95298447 375.25 -4.60655827e+01 -3.16708073e+01 5.59023966e+01 -2.53929470 0.93474155 375.50 -5.24710954e+01 -2.80207395e+01 5.94842643e+01 -2.65109902 0.95056193 375.75 -5.30126575e+01 -2.16989286e+01 5.72816320e+01 -2.75308114 0.94194726 376.00 -5.23004286e+01 -1.65623905e+01 5.48602553e+01 -2.83490611 0.93806513 376.25 -5.31182901e+01 -9.73148897e+00 5.40023576e+01 -2.96039791 0.91021940 376.50 -5.39336741e+01 -5.26141978e+00 5.41897014e+01 -3.04434684 0.95214298 376.75 -5.36948195e+01 -3.39030126e+00 5.38017452e+01 -3.07853617 0.94697529 377.00 -5.44272321e+01 -2.69386143e+00 5.44938573e+01 -3.09213828 0.95313450 377.25 -5.72482757e+01 -1.90534544e+00 5.72799739e+01 -3.10832279 0.94397819 377.50 -5.92755136e+01 -2.04757038e+00 5.93108680e+01 -3.10706311 0.94652058 377.75 -6.90916478e+01 3.65519091e+00 6.91882665e+01 3.08873841 0.94223919 378.00 -7.16500671e+01 1.06987038e+01 7.24444226e+01 2.99336896 0.94229194 378.25 -6.61610328e+01 2.68719710e+01 7.14099789e+01 2.75578716 0.90635888 378.50 -6.39916814e+01 3.28192862e+01 7.19169023e+01 2.66770371 0.92476386 378.75 -5.35806558e+01 4.47876140e+01 6.98342111e+01 2.44534655 0.90000565 379.00 -4.86165915e+01 5.11057170e+01 7.05362835e+01 2.33123910 0.90914254 379.25 -2.97314756e+01 4.60422004e+01 5.48073431e+01 2.14417382 0.86947015 379.50 -2.64563156e+01 4.28047448e+01 5.03207990e+01 2.12439652 0.87184688 379.75 -2.68627886e+01 3.23894124e+01 4.20794896e+01 2.26319069 0.81867919 380.00 -3.07548663e+01 3.10595390e+01 4.37099161e+01 2.35126570 0.83203964 380.25 -3.25441708e+01 3.91162179e+01 5.08841975e+01 2.26473931 0.90401960 380.50 -2.79709859e+01 4.17799074e+01 5.02785910e+01 2.16074696 0.89103093 380.75 -2.35910749e+01 3.49161680e+01 4.21387898e+01 2.16499173 0.90137880 381.00 -2.60476805e+01 3.22791240e+01 4.14779883e+01 2.24976151 0.91299333 381.25 -3.32744941e+01 3.53314329e+01 4.85335153e+01 2.32622153 0.93723293 381.50 -3.40633408e+01 3.94499560e+01 5.21211110e+01 2.28305118 0.93202842 381.75 -3.28554608e+01 4.57214474e+01 5.63021497e+01 2.19389716 0.92825378 382.00 -2.93820219e+01 4.62208342e+01 5.47692316e+01 2.13704438 0.92135042 382.25 -2.14164109e+01 4.89409785e+01 5.34217374e+01 1.98328793 0.93902411 382.50 -1.77866282e+01 4.74973449e+01 5.07184574e+01 1.92910775 0.94185458 382.75 -1.56794179e+01 4.59847536e+01 4.85843772e+01 1.89940400 0.94307365 383.00 -1.64451380e+01 4.37920881e+01 4.67780883e+01 1.93002948 0.93188491 383.25 -1.86714806e+01 4.25192321e+01 4.64382309e+01 1.98457428 0.92864544 383.50 -2.03200868e+01 4.20257409e+01 4.66804973e+01 2.02116938 0.91324812 383.75 -2.35066821e+01 3.92112444e+01 4.57174560e+01 2.11083949 0.92238268 384.00 -2.76074431e+01 3.69876557e+01 4.61547136e+01 2.21198697 0.89070066 384.25 -3.49283005e+01 3.50083508e+01 4.94527128e+01 2.35504988 0.88319787 384.50 -3.96357071e+01 3.64269350e+01 5.38322475e+01 2.39835541 0.83103929 384.75 -4.88659686e+01 3.60094566e+01 6.07006083e+01 2.50652675 0.84397977 385.00 -5.44149121e+01 4.50739783e+01 7.06586596e+01 2.44980927 0.77786559 385.25 -6.58475265e+01 6.36434678e+01 9.15772228e+01 2.37321379 0.79620911 385.50 -6.30466010e+01 7.76303722e+01 1.00006743e+02 2.25289499 0.66141912 385.75 -7.93031913e+01 1.03318881e+02 1.30245105e+02 2.22543992 0.67685444 386.00 -5.00171009e+01 1.21774557e+02 1.31646318e+02 1.96052282 0.45019609 386.25 -7.79679638e-01 1.67925219e+02 1.67927029e+02 1.57543931 0.48024235 386.50 8.91745283e+01 1.63201714e+02 1.85975525e+02 1.07071599 0.43813787 386.75 2.09351160e+02 1.40503954e+02 2.52129469e+02 0.59109319 0.60129768 387.00 2.18600898e+02 5.60069410e+01 2.25661539e+02 0.25081136 0.58459092 387.25 2.18220744e+02 5.67032864e+00 2.18294401e+02 0.02597852 0.68776741 387.50 1.82990991e+02 -2.70395839e+01 1.84977949e+02 -0.14670299 0.71808740 387.75 1.56255358e+02 -5.12231267e+01 1.64437056e+02 -0.31677746 0.76118788 388.00 1.15286755e+02 -6.54631585e+01 1.32576246e+02 -0.51642836 0.78401621 388.25 9.57671516e+01 -7.14806391e+01 1.19502423e+02 -0.64119337 0.82138501 388.50 6.71179588e+01 -6.93819990e+01 9.65333216e+01 -0.80198302 0.81010693 388.75 5.34058889e+01 -6.37701999e+01 8.31794889e+01 -0.87361931 0.80417368 389.00 4.04630989e+01 -4.56504991e+01 6.10018888e+01 -0.84556449 0.76452412 389.25 3.38135566e+01 -4.13530339e+01 5.34175067e+01 -0.88536737 0.79600585 389.50 2.56008256e+01 -3.90675424e+01 4.67084054e+01 -0.99070671 0.82841028 389.75 2.27171690e+01 -3.81398262e+01 4.43927484e+01 -1.03359733 0.86369129 390.00 1.60947337e+01 -3.20140291e+01 3.58320878e+01 -1.10495910 0.84596960 390.25 1.44024246e+01 -2.76878319e+01 3.12097080e+01 -1.09114195 0.86294909 390.50 1.29286306e+01 -2.23198911e+01 2.57939340e+01 -1.04577950 0.89096078 390.75 1.19195788e+01 -2.06659794e+01 2.38570548e+01 -1.04763062 0.90650465 391.00 9.98133915e+00 -1.90769478e+01 2.15303755e+01 -1.08874992 0.90638583 391.25 8.67159535e+00 -1.72862353e+01 1.93393510e+01 -1.10583165 0.88914328 391.50 6.10652109e+00 -1.29698151e+01 1.43354701e+01 -1.13075942 0.80546608 391.75 4.60363401e+00 -8.82632256e+00 9.95476851e+00 -1.09003408 0.68838447 392.00 4.43922900e+00 -3.70044425e+00 5.77927692e+00 -0.69488273 0.58457060 392.25 5.73087366e+00 -2.68817937e+00 6.33002538e+00 -0.43859866 0.66597276 392.50 8.08933323e+00 -9.78945890e-01 8.14835242e+00 -0.12043125 0.78574735 392.75 8.76925807e+00 -9.77456891e-02 8.76980281e+00 -0.01114594 0.79935614 393.00 9.27375640e+00 7.81720432e-01 9.30664518e+00 0.08409503 0.82336944 393.25 9.54102650e+00 1.49036483e+00 9.65672687e+00 0.15495371 0.82636353 393.50 9.64201725e+00 2.54980254e+00 9.97346427e+00 0.25852895 0.89179346 393.75 9.40426952e+00 2.52176481e+00 9.73650774e+00 0.26198772 0.86975811 394.00 8.73750148e+00 2.69179594e+00 9.14274015e+00 0.29884746 0.83968471 394.25 8.62176345e+00 4.08378332e+00 9.54002574e+00 0.44235434 0.80622683 394.50 8.79634879e+00 5.98025965e+00 1.06366939e+01 0.59707889 0.83509310 394.75 9.41449736e+00 7.28670619e+00 1.19049925e+01 0.65867739 0.82099105 395.00 1.01761309e+01 9.84546989e+00 1.41593403e+01 0.76888445 0.86775858 395.25 1.07106336e+01 1.10291447e+01 1.53739944e+01 0.80004819 0.80501856 395.50 1.33691866e+01 1.19328818e+01 1.79200674e+01 0.72869272 0.79882730 395.75 1.61927578e+01 1.15417329e+01 1.98850951e+01 0.61924598 0.81663418 396.00 1.71185981e+01 1.10597468e+01 2.03804907e+01 0.57360480 0.85282805 396.25 1.78796224e+01 9.52585825e+00 2.02588961e+01 0.48952439 0.79751191 396.50 1.87554931e+01 9.71851053e+00 2.11238720e+01 0.47807674 0.83224524 396.75 1.79778328e+01 1.01415156e+01 2.06410468e+01 0.51361335 0.78494331 397.00 2.00578528e+01 1.02800848e+01 2.25388022e+01 0.47361471 0.77401031 397.25 2.02150068e+01 8.21698719e+00 2.18212139e+01 0.38607970 0.73764845 397.50 2.09386683e+01 6.77976050e+00 2.20089296e+01 0.31313836 0.79069893 397.75 2.18870301e+01 6.50679304e+00 2.28337566e+01 0.28896862 0.79804379 398.00 2.09833205e+01 7.74865892e+00 2.23683136e+01 0.35374388 0.82148268 398.25 1.98855649e+01 9.18724852e+00 2.19052786e+01 0.43279307 0.81332401 398.50 1.91098415e+01 1.04113255e+01 2.17619334e+01 0.49885358 0.78672467 398.75 1.85495147e+01 1.24044467e+01 2.23149008e+01 0.58942336 0.72183173 399.00 1.82071981e+01 1.38008072e+01 2.28465390e+01 0.64859280 0.73478716 399.25 1.56977882e+01 1.93921747e+01 2.49494889e+01 0.89029501 0.64516983 399.50 1.42150796e+01 2.00425575e+01 2.45717846e+01 0.95389271 0.53745910 399.75 7.89121724e+00 2.38024265e+01 2.50764196e+01 1.25066970 0.36939451 400.00 2.87767686e+00 2.18669862e+01 2.20555233e+01 1.43994907 0.24287047 400.25 -1.95666600e+01 1.01927172e+01 2.20623132e+01 2.66134734 0.24416663 400.50 -2.64727864e+01 2.48519340e-01 2.64739528e+01 3.13220520 0.36923759 400.75 -1.62944813e+01 -1.52934987e+01 2.23472867e+01 -2.38787261 0.46923097 401.00 -1.31577781e+01 -1.72195522e+01 2.16711814e+01 -2.22327220 0.60595487 401.25 -9.29125388e+00 -1.64239911e+01 1.88699465e+01 -2.08562265 0.74109000 401.50 -5.70043022e+00 -1.70941413e+01 1.80195608e+01 -1.89267235 0.78031563 401.75 7.77613106e-01 -1.46557522e+01 1.46763672e+01 -1.51778747 0.80128403 402.00 2.06727418e+00 -1.47875517e+01 1.49313532e+01 -1.43189824 0.82894088 402.25 3.29877800e+00 -1.38640952e+01 1.42511428e+01 -1.33720312 0.87247898 402.50 4.27443476e+00 -1.41783245e+01 1.48086352e+01 -1.27798529 0.86163987 402.75 6.72972203e+00 -1.32120064e+01 1.48272139e+01 -1.09968552 0.90587762 403.00 7.17406326e+00 -1.28586033e+01 1.47244987e+01 -1.06189336 0.87590093 403.25 7.30085064e+00 -1.13782452e+01 1.35191303e+01 -1.00031349 0.78924706 403.50 7.97230092e+00 -9.59124464e+00 1.24719508e+01 -0.87731479 0.69552059 403.75 1.07006425e+01 -4.79755486e+00 1.17269042e+01 -0.42147485 0.58635038 404.00 1.10559242e+01 -1.41348187e+00 1.11459136e+01 -0.12715855 0.34210892 404.25 4.74872552e+00 7.64970520e+00 9.00379829e+00 1.01524289 0.11205722 404.50 -7.13106870e+00 1.54465008e+00 7.29644329e+00 2.92827957 0.07486893 404.75 -1.32117599e+01 -6.75258388e+00 1.48373848e+01 -2.66910132 0.46807004 405.00 -8.59372336e+00 -8.67895895e+00 1.22137795e+01 -2.35125983 0.52232491 405.25 -5.72363429e+00 -1.05257449e+01 1.19812894e+01 -2.06884751 0.70120235 405.50 -4.23163165e+00 -1.23956814e+01 1.30980771e+01 -1.89977088 0.71076365 405.75 -2.16462183e+00 -1.53782749e+01 1.55298721e+01 -1.71063604 0.84286839 406.00 -1.11942277e+00 -1.71471153e+01 1.71836163e+01 -1.63598726 0.80430684 406.25 -1.19175175e+00 -1.98453915e+01 1.98811428e+01 -1.63077611 0.82741575 406.50 -2.39917632e+00 -2.38912196e+01 2.40113811e+01 -1.67088163 0.77022985 406.75 -5.93417706e+00 -2.80170390e+01 2.86385917e+01 -1.77951761 0.81233442 407.00 -1.57523069e+01 -3.13302814e+01 3.50673881e+01 -2.03666719 0.79301209 407.25 -2.15435158e+01 -3.26421549e+01 3.91105273e+01 -2.15416279 0.82306480 407.50 -3.10579431e+01 -2.76824716e+01 4.16042674e+01 -2.41359557 0.73548341 407.75 -3.62886973e+01 -1.59526399e+01 3.96403365e+01 -2.72741798 0.64792650 408.00 -3.01885567e+01 2.43523674e+00 3.02866197e+01 3.06109940 0.63939282 408.25 -2.74927875e+01 1.05478503e+01 2.94467402e+01 2.77525239 0.68160995 408.50 -2.02957200e+01 1.65688309e+01 2.62000459e+01 2.45694899 0.66611071 408.75 -1.77253690e+01 2.00173082e+01 2.67372649e+01 2.29554357 0.73356767 409.00 -1.21391963e+01 1.75435812e+01 2.13339478e+01 2.17609588 0.61090909 409.25 -1.30008151e+01 1.65092317e+01 2.10137080e+01 2.23786105 0.65635171 409.50 -7.20662903e+00 1.80704136e+01 1.94544429e+01 1.95027486 0.55067199 409.75 -3.04210972e+00 1.88916714e+01 1.91350380e+01 1.73045489 0.63154159 410.00 4.13737398e-01 1.66597107e+01 1.66648474e+01 1.54596682 0.65523931 410.25 9.39192266e-01 1.58753508e+01 1.59031080e+01 1.51170479 0.67097944 410.50 9.43071415e-01 1.47765019e+01 1.48065658e+01 1.50706040 0.65861788 410.75 1.53667721e+00 1.37535190e+01 1.38390991e+01 1.45952806 0.63762771 411.00 3.91738054e+00 1.20102089e+01 1.26329326e+01 1.25550576 0.69219008 411.25 4.30413687e+00 1.15379118e+01 1.23145850e+01 1.21374251 0.73882282 411.50 4.21971985e+00 1.11965886e+01 1.19653513e+01 1.21038240 0.78446165 411.75 4.21259961e+00 1.13832787e+01 1.21377523e+01 1.21635564 0.77929036 412.00 3.98161100e+00 1.28737820e+01 1.34754402e+01 1.27084712 0.80456864 412.25 4.10455103e+00 1.27532519e+01 1.33974913e+01 1.25942203 0.84572572 412.50 4.07031326e+00 1.31256111e+01 1.37422385e+01 1.27009517 0.88849775 412.75 4.95664737e+00 1.38013812e+01 1.46644631e+01 1.22600105 0.86679179 413.00 5.19973440e+00 1.43870912e+01 1.52978963e+01 1.22398719 0.91244876 413.25 6.02891991e+00 1.45309040e+01 1.57319752e+01 1.17750867 0.93069213 413.50 7.98611030e+00 1.48542981e+01 1.68649972e+01 1.07750013 0.92556494 413.75 9.00562616e+00 1.54061558e+01 1.78451937e+01 1.04181663 0.92430761 414.00 1.10680045e+01 1.75642331e+01 2.07606119e+01 1.00850616 0.93967795 414.25 1.25183702e+01 1.75749207e+01 2.15774751e+01 0.95187222 0.94825885 414.50 1.40385700e+01 1.69814671e+01 2.20329679e+01 0.87998591 0.96474573 414.75 1.59363160e+01 1.64070850e+01 2.28726607e+01 0.79995247 0.95125881 415.00 1.98732017e+01 1.54243258e+01 2.51565890e+01 0.66001998 0.96996038 415.25 2.12705281e+01 1.37560682e+01 2.53311030e+01 0.57406571 0.95366930 415.50 2.26764133e+01 1.07896325e+01 2.51124648e+01 0.44410787 0.95247901 415.75 2.25908955e+01 7.79216012e+00 2.38969939e+01 0.33214635 0.94125457 416.00 2.40655554e+01 5.95235375e+00 2.47907538e+01 0.24247276 0.95544343 416.25 2.32192003e+01 3.41677585e+00 2.34692484e+01 0.14610448 0.91849840 416.50 2.15129569e+01 1.59055881e+00 2.15716757e+01 0.07380064 0.93734409 416.75 2.10069411e+01 1.59475968e+00 2.10673879e+01 0.07577051 0.94705447 417.00 2.02529327e+01 1.86956133e+00 2.03390399e+01 0.09204978 0.95880936 417.25 2.04950296e+01 1.65950189e+00 2.05621055e+01 0.08079468 0.95210145 417.50 2.10634913e+01 8.17844263e-01 2.10793628e+01 0.03880808 0.95055534 417.75 2.19403917e+01 -1.52427511e-01 2.19409212e+01 -0.00694724 0.95050741 418.00 2.24228735e+01 -1.56648080e+00 2.24775247e+01 -0.06974752 0.96176913 418.25 2.10764011e+01 -3.17551406e+00 2.13142810e+01 -0.14954202 0.96272173 418.50 2.08671346e+01 -4.21140090e+00 2.12878651e+01 -0.19914475 0.97133607 418.75 1.91401562e+01 -4.61596645e+00 1.96888985e+01 -0.23664775 0.96705357 419.00 1.87275269e+01 -4.73078105e+00 1.93158109e+01 -0.24743465 0.96971422 419.25 1.77467745e+01 -4.89900873e+00 1.84105484e+01 -0.26934273 0.95759655 419.50 1.70665274e+01 -5.38492583e+00 1.78959153e+01 -0.30563888 0.96716419 419.75 1.77600515e+01 -5.91932399e+00 1.87205188e+01 -0.32171543 0.97653611 420.00 1.77104739e+01 -5.71712263e+00 1.86103836e+01 -0.31225008 0.97507638 420.25 1.64312751e+01 -5.42142877e+00 1.73025631e+01 -0.31869860 0.96143822 420.50 1.63841276e+01 -5.68886596e+00 1.73436684e+01 -0.33419438 0.96600896 420.75 1.60306562e+01 -6.15283236e+00 1.71708848e+01 -0.36647782 0.96165702 421.00 1.56950114e+01 -6.45365265e+00 1.69700623e+01 -0.39011669 0.96676253 421.25 1.54058262e+01 -6.26374882e+00 1.66305150e+01 -0.38616856 0.96621138 421.50 1.50340495e+01 -6.70412702e+00 1.64611046e+01 -0.41946379 0.96495094 421.75 1.35587086e+01 -6.93056111e+00 1.52273194e+01 -0.47252936 0.96996495 422.00 1.27914477e+01 -6.98624353e+00 1.45749351e+01 -0.49989426 0.96615358 422.25 1.20573314e+01 -6.50854381e+00 1.37018387e+01 -0.49497817 0.95771295 422.50 1.18466917e+01 -5.46524283e+00 1.30465698e+01 -0.43223650 0.94729504 422.75 1.15183828e+01 -3.06912587e+00 1.19202632e+01 -0.26040438 0.94125228 423.00 1.20288368e+01 -2.17733602e+00 1.22243081e+01 -0.17907077 0.94506199 423.25 1.37417439e+01 -2.30881747e+00 1.39343520e+01 -0.16646017 0.96068334 423.50 1.41392804e+01 -2.92925711e+00 1.44395220e+01 -0.20428171 0.96189919 423.75 1.49424308e+01 -2.58700557e+00 1.51647234e+01 -0.17143212 0.97039915 424.00 1.54021811e+01 -2.45105853e+00 1.55959889e+01 -0.15781379 0.97474558 424.25 1.60744849e+01 -2.44318448e+00 1.62590964e+01 -0.15083702 0.97956106 424.50 1.67084729e+01 -2.39882901e+00 1.68797941e+01 -0.14259521 0.97461488 424.75 1.75606517e+01 -2.82334971e+00 1.77861686e+01 -0.15941282 0.97423025 425.00 1.81612725e+01 -3.32038126e+00 1.84623062e+01 -0.18083041 0.96694118 425.25 1.87480607e+01 -3.19951549e+00 1.90191135e+01 -0.16903007 0.96776446 425.50 1.88601004e+01 -3.55938042e+00 1.91930346e+01 -0.18653149 0.96323043 425.75 1.99137991e+01 -4.64424850e+00 2.04481891e+01 -0.22912218 0.96334223 426.00 1.97585604e+01 -5.64412224e+00 2.05488887e+01 -0.27824441 0.95464817 426.25 1.99360392e+01 -6.85535373e+00 2.10817821e+01 -0.33120106 0.96630769 426.50 1.94772408e+01 -6.64474135e+00 2.05794921e+01 -0.32877269 0.95891737 426.75 1.93742667e+01 -7.27044163e+00 2.06935142e+01 -0.35900105 0.96564539 427.00 1.89743490e+01 -7.55156649e+00 2.04218529e+01 -0.37877084 0.95865411 427.25 1.95757489e+01 -7.45449105e+00 2.09470614e+01 -0.36384793 0.96364755 427.50 1.92740645e+01 -8.40902840e+00 2.10285834e+01 -0.41139207 0.95905680 427.75 1.91087503e+01 -9.23149381e+00 2.12218005e+01 -0.45003883 0.96524222 428.00 1.90697932e+01 -8.85622909e+00 2.10259317e+01 -0.43477360 0.95299591 428.25 1.91324760e+01 -9.04726056e+00 2.11637559e+01 -0.44171271 0.95890539 428.50 1.91227444e+01 -9.89432108e+00 2.15308370e+01 -0.47747931 0.95145412 428.75 1.82806990e+01 -1.02023617e+01 2.09349502e+01 -0.50903672 0.95929564 429.00 1.85442453e+01 -1.08948564e+01 2.15078341e+01 -0.53118212 0.95365048 429.25 1.80778032e+01 -1.15447558e+01 2.14496703e+01 -0.56833001 0.96266346 429.50 1.73099389e+01 -1.03914490e+01 2.01895071e+01 -0.54065249 0.93509019 429.75 1.71167158e+01 -1.03753675e+01 2.00157491e+01 -0.54493229 0.95481015 430.00 1.71758249e+01 -1.11791530e+01 2.04934726e+01 -0.57698346 0.95365385 430.25 1.69642084e+01 -1.14932113e+01 2.04909315e+01 -0.59546354 0.95653279 430.50 1.62735828e+01 -9.45870149e+00 1.88227663e+01 -0.52650401 0.94355820 430.75 1.63642055e+01 -8.97375679e+00 1.86632133e+01 -0.50159643 0.95328358 431.00 1.73879203e+01 -8.39276103e+00 1.93074651e+01 -0.44969397 0.94305853 431.25 1.78035391e+01 -8.82321313e+00 1.98699546e+01 -0.46011146 0.93660871 431.50 1.84155563e+01 -9.76998195e+00 2.08467086e+01 -0.48777128 0.95439118 431.75 1.82754026e+01 -9.84295068e+00 2.07575051e+01 -0.49404102 0.95789948 432.00 1.86812129e+01 -9.64522759e+00 2.10242272e+01 -0.47660738 0.94773453 432.25 1.91228878e+01 -9.45616383e+00 2.13331637e+01 -0.45923356 0.95522891 432.50 1.93055445e+01 -8.02941560e+00 2.09087437e+01 -0.39414827 0.94929150 432.75 2.02147034e+01 -7.08489382e+00 2.14203164e+01 -0.33710434 0.94570630 433.00 2.32478556e+01 -8.43835168e+00 2.47319342e+01 -0.34818528 0.95919960 433.25 2.29100310e+01 -9.96835887e+00 2.49847493e+01 -0.41040174 0.96231852 433.50 2.15049308e+01 -1.23153986e+01 2.47816684e+01 -0.52008741 0.96872049 433.75 2.08087072e+01 -1.26905974e+01 2.43732140e+01 -0.54764495 0.95941949 434.00 2.04070774e+01 -1.30057396e+01 2.41991337e+01 -0.56740618 0.97075921 434.25 1.97951324e+01 -1.29578538e+01 2.36591048e+01 -0.57960076 0.96437940 434.50 1.82404690e+01 -1.25583285e+01 2.21455712e+01 -0.60295735 0.97167249 434.75 1.81931798e+01 -1.19465317e+01 2.17649124e+01 -0.58103513 0.96983227 435.00 1.78856248e+01 -1.06633641e+01 2.08231340e+01 -0.53761882 0.97352693 435.25 1.73794492e+01 -9.87051366e+00 1.99868030e+01 -0.51651359 0.96595662 435.50 1.66498104e+01 -8.76777362e+00 1.88172803e+01 -0.48469969 0.96388925 435.75 1.61806782e+01 -7.17650447e+00 1.77007504e+01 -0.41745469 0.94374233 436.00 1.62910534e+01 -4.57863132e+00 1.69222423e+01 -0.27398385 0.94852672 436.25 1.67815436e+01 -3.02669070e+00 1.70523038e+01 -0.17843997 0.91882418 436.50 1.80239328e+01 7.88386313e-01 1.80411670e+01 0.04371322 0.90313119 436.75 2.08102417e+01 3.36975903e+00 2.10813053e+01 0.16053449 0.85870501 437.00 2.55036912e+01 6.43347479e+00 2.63026208e+01 0.24710141 0.89978956 437.25 2.91739997e+01 3.65146776e+00 2.94016236e+01 0.12451422 0.83218105 437.50 3.46054759e+01 -2.39792208e+00 3.46884562e+01 -0.06918255 0.87392610 437.75 3.38393859e+01 -5.10954371e+00 3.42229671e+01 -0.14986192 0.90458856 438.00 3.38025755e+01 -6.22535419e+00 3.43710510e+01 -0.18212722 0.94027760 438.25 3.12415820e+01 -6.48984093e+00 3.19085330e+01 -0.20481792 0.91232339 438.50 3.07651466e+01 -5.57235178e+00 3.12657216e+01 -0.17918288 0.91388031 438.75 3.13507494e+01 -4.13132832e+00 3.16217861e+01 -0.13102272 0.89258893 439.00 3.31710359e+01 -3.78280563e+00 3.33860336e+01 -0.11354888 0.92457819 439.25 3.17491842e+01 -2.84078031e+00 3.18760212e+01 -0.08923806 0.90233749 439.50 3.27891100e+01 -2.14297941e+00 3.28590641e+01 -0.06526362 0.92183829 439.75 3.27705149e+01 -9.49361027e-01 3.27842635e+01 -0.02896188 0.91656373 440.00 3.30752676e+01 3.82441005e-01 3.30774786e+01 0.01156223 0.93474050 440.25 3.35644564e+01 2.30210724e+00 3.36433118e+01 0.06848040 0.91682265 440.50 3.39139369e+01 4.20799655e+00 3.41740011e+01 0.12344775 0.91797932 440.75 3.29612191e+01 6.92692418e+00 3.36812150e+01 0.20713946 0.89440285 441.00 3.40054957e+01 8.79879843e+00 3.51253839e+01 0.25319345 0.90435612 441.25 3.62367101e+01 9.30099595e+00 3.74113310e+01 0.25124949 0.88757296 441.50 3.68394604e+01 9.72118691e+00 3.81004898e+01 0.25799868 0.88346140 441.75 3.63923056e+01 1.38316480e+01 3.89321768e+01 0.36320876 0.86946232 442.00 3.82853707e+01 1.60733889e+01 4.15225655e+01 0.39748440 0.89389109 442.25 3.93659575e+01 1.47069067e+01 4.20234663e+01 0.35753792 0.88318793 442.50 3.96929075e+01 1.47996848e+01 4.23622187e+01 0.35688848 0.86722824 442.75 4.30112087e+01 1.41654084e+01 4.52838036e+01 0.31815429 0.85828369 443.00 4.29134933e+01 1.45293138e+01 4.53063888e+01 0.32645806 0.86423603 443.25 4.39320177e+01 1.63922178e+01 4.68905852e+01 0.35712749 0.88863103 443.50 4.55359715e+01 1.62857821e+01 4.83606389e+01 0.34347056 0.89617260 443.75 4.67244257e+01 1.69365512e+01 4.96992829e+01 0.34774707 0.86703139 444.00 4.28041365e+01 1.48409435e+01 4.53039480e+01 0.33374756 0.82692114 444.25 3.96779771e+01 1.47679691e+01 4.23371560e+01 0.35630977 0.77432668 444.50 3.83568750e+01 1.54184886e+01 4.13398071e+01 0.38220744 0.79777142 444.75 3.95686784e+01 1.55814314e+01 4.25260075e+01 0.37513452 0.89248692 445.00 3.98449011e+01 1.59769006e+01 4.29287491e+01 0.38134859 0.88706999 445.25 4.02928957e+01 1.39893092e+01 4.26522944e+01 0.33416970 0.87957946 445.50 4.07098699e+01 1.14251992e+01 4.22827232e+01 0.27361076 0.88222635 445.75 4.03522049e+01 1.02786076e+01 4.16407278e+01 0.24941825 0.84325076 446.00 3.88692933e+01 9.39076243e+00 3.99876028e+01 0.23705586 0.83377350 446.25 3.96812685e+01 4.94094011e+00 3.99876976e+01 0.12387810 0.82724650 446.50 3.64687907e+01 1.47338623e+00 3.64985420e+01 0.04037933 0.85539794 446.75 3.33302440e+01 -8.84832899e-01 3.33419869e+01 -0.02654121 0.89153761 447.00 2.73074689e+01 -1.76919583e+00 2.73647202e+01 -0.06469756 0.83758566 447.25 2.37568692e+01 -1.98687984e+00 2.38398097e+01 -0.08343973 0.89346078 447.50 2.09322052e+01 -2.89152491e+00 2.11309756e+01 -0.13726889 0.87030126 447.75 1.77421492e+01 -3.01692261e+00 1.79968241e+01 -0.16843164 0.87429416 448.00 1.53482242e+01 -2.61868042e+00 1.55700184e+01 -0.16899055 0.82429691 448.25 1.29731366e+01 -1.71889869e+00 1.30865154e+01 -0.13172949 0.81239423 448.50 1.11116252e+01 -3.45323766e-01 1.11169898e+01 -0.03106770 0.79469754 448.75 9.54848032e+00 1.45978440e-01 9.54959612e+00 0.01528694 0.77197855 449.00 8.18564344e+00 2.47564474e-01 8.18938622e+00 0.03023452 0.68111758 449.25 8.07074276e+00 1.10548073e+00 8.14610191e+00 0.13612674 0.71629447 449.50 7.72134828e+00 -4.62545667e-02 7.72148683e+00 -0.00599041 0.68961651 449.75 7.31935041e+00 -3.41996033e-01 7.32733592e+00 -0.04669096 0.70018138 450.00 4.84941625e+00 -2.34214453e-02 4.84947281e+00 -0.00482971 0.34646695 450.25 3.42468235e+00 -2.39507830e-02 3.42476610e+00 -0.00699346 0.23301533 450.50 2.19005444e+00 -2.79384563e-02 2.19023264e+00 -0.01275628 0.14536010 450.75 1.73431126e+00 -7.49611839e-01 1.88937912e+00 -0.40797393 0.10087184 451.00 -1.85153525e+00 -1.23875994e+00 2.22771384e+00 -2.55194549 0.11882232 451.25 -3.74978305e+00 -5.03399521e-01 3.78342226e+00 -3.00814289 0.34535720 451.50 -5.73630248e+00 1.81731818e+00 6.01729271e+00 2.83478604 0.53591950 451.75 -6.11841614e+00 3.77122865e+00 7.18729307e+00 2.58922084 0.67100836 452.00 -4.55329424e+00 5.19313971e+00 6.90660470e+00 2.29063937 0.76034424 452.25 -3.94296762e+00 5.36099310e+00 6.65486593e+00 2.20494748 0.76417682 452.50 -3.78814158e+00 5.46696662e+00 6.65114582e+00 2.17675122 0.73928861 452.75 -3.66546484e+00 5.71002539e+00 6.78527983e+00 2.14148100 0.78546926 453.00 -2.79009416e+00 5.91905029e+00 6.54368258e+00 2.01128309 0.87870289 453.25 -2.66458944e+00 5.75243502e+00 6.33960138e+00 2.00458180 0.87739211 453.50 -3.13557406e+00 6.05807931e+00 6.82144776e+00 2.04841317 0.89137679 453.75 -3.09674006e+00 6.34721820e+00 7.06236347e+00 2.02470855 0.90665557 454.00 -2.54970790e+00 6.91833393e+00 7.37321875e+00 1.92389464 0.95492315 454.25 -2.19827872e+00 6.96751983e+00 7.30607705e+00 1.87641537 0.94505628 454.50 -8.67868733e-01 6.83129282e+00 6.88620053e+00 1.69716250 0.89882911 454.75 1.42310848e-02 6.70727120e+00 6.70728629e+00 1.56867459 0.88451700 455.00 1.83333965e+00 5.71137243e+00 5.99840890e+00 1.26018826 0.84809812 455.25 2.82992276e+00 4.34252829e+00 5.18324365e+00 0.99324359 0.77065542 455.50 3.39866795e+00 1.38380272e+00 3.66958496e+00 0.38666378 0.66196556 455.75 2.82201837e+00 -2.06061399e-01 2.82953159e+00 -0.07288979 0.51316025 456.00 2.46912300e+00 -2.19926307e+00 3.30655810e+00 -0.72765659 0.70655620 456.25 1.59030780e+00 -3.09969482e+00 3.48384656e+00 -1.09676091 0.62882665 456.50 -1.17417275e+00 -4.99936702e+00 5.13540186e+00 -1.80147967 0.73704861 456.75 -2.38931884e+00 -6.51367911e+00 6.93807322e+00 -1.92237236 0.81276731 457.00 -4.46838196e+00 -8.54519063e+00 9.64296222e+00 -2.05260501 0.86605421 457.25 -7.66454667e+00 -8.03006834e+00 1.11007780e+01 -2.33290908 0.85658225 457.50 -1.21974851e+01 -6.61016742e+00 1.38734623e+01 -2.64496732 0.87584913 457.75 -1.43664859e+01 -2.37021202e+00 1.45606944e+01 -2.97808353 0.88191990 458.00 -1.42500049e+01 6.89352238e-01 1.42666691e+01 3.09325476 0.92454111 458.25 -1.26586478e+01 2.81980717e+00 1.29689119e+01 2.92241380 0.92139657 458.50 -1.15966095e+01 4.22904431e+00 1.23436691e+01 2.79190076 0.94525978 458.75 -1.02695613e+01 5.48865555e+00 1.16442788e+01 2.65075965 0.93556394 459.00 -8.12731091e+00 5.93492724e+00 1.00636248e+01 2.51085516 0.90477723 459.25 -6.14122656e+00 4.30660679e+00 7.50076834e+00 2.53002043 0.83002244 459.50 -5.25968765e+00 3.06028727e+00 6.08520109e+00 2.61463446 0.84473006 459.75 -5.75675520e+00 1.57229286e+00 5.96760717e+00 2.87497383 0.80859691 460.00 -6.60434404e+00 6.08276556e-01 6.63229678e+00 3.04974927 0.89497919 460.25 -8.31693092e+00 5.38394411e-01 8.33433911e+00 3.07694811 0.89752899 460.50 -9.66249530e+00 1.46581788e+00 9.77304648e+00 2.99103878 0.93516262 460.75 -8.63392748e+00 2.77532708e+00 9.06902112e+00 2.83058009 0.95116553 461.00 -7.95896720e+00 2.82704448e+00 8.44614347e+00 2.80029069 0.95058851 461.25 -7.40112463e+00 2.08733408e+00 7.68983806e+00 2.86670316 0.93877986 461.50 -7.57663953e+00 1.70332163e+00 7.76574344e+00 2.92045689 0.94053201 461.75 -8.40067510e+00 1.47758583e+00 8.52963082e+00 2.96748459 0.93650480 462.00 -8.84107507e+00 1.38856897e+00 8.94945429e+00 2.98580645 0.94214237 462.25 -9.20528740e+00 1.53851767e+00 9.33297127e+00 2.97598918 0.94347249 462.50 -9.39187155e+00 1.82774491e+00 9.56806682e+00 2.94938586 0.93452120 462.75 -1.04090957e+01 2.66959563e+00 1.07459767e+01 2.89053618 0.87746484 463.00 -1.10709929e+01 4.16250152e+00 1.18276499e+01 2.78196074 0.87517352 463.25 -9.24505528e+00 6.73064719e+00 1.14355874e+01 2.51230340 0.81080942 463.50 -7.49100427e+00 7.67898620e+00 1.07276267e+01 2.34380343 0.81201778 463.75 -3.53988479e+00 6.00881582e+00 6.97399827e+00 2.10317386 0.77449749 464.00 -2.27416664e+00 4.58727909e+00 5.12005502e+00 2.03104219 0.72108992 464.25 -2.91983226e+00 2.55158495e+00 3.87762894e+00 2.42339697 0.75931824 464.50 -3.84406676e+00 1.62492556e+00 4.17339578e+00 2.74166323 0.79098902 464.75 -5.08332463e+00 5.42167213e-01 5.11215557e+00 3.03533831 0.86340750 465.00 -6.11091410e+00 3.01839947e-01 6.11836403e+00 3.09223918 0.88397795 465.25 -7.79304849e+00 1.01963996e+00 7.85947011e+00 3.01149201 0.93976328 465.50 -8.21157514e+00 1.75630888e+00 8.39729642e+00 2.93088525 0.92582332 465.75 -8.79707577e+00 3.85997386e+00 9.60666125e+00 2.72810903 0.93880769 466.00 -7.87078738e+00 5.53340924e+00 9.62122195e+00 2.52883521 0.90316438 466.25 -5.73303372e+00 7.99756189e+00 9.84015609e+00 2.19274020 0.88710063 466.50 -2.76748543e+00 7.72597986e+00 8.20668876e+00 1.91476204 0.67966642 466.75 2.45794944e+00 5.80258249e+00 6.30170445e+00 1.17011567 0.66485771 467.00 3.44377042e+00 3.13286682e+00 4.65557829e+00 0.73815939 0.54358260 467.25 4.09445544e+00 1.28151758e-01 4.09646045e+00 0.03128864 0.50999128 467.50 3.26867155e+00 -3.57896341e+00 4.84697770e+00 -0.83068091 0.46127070 467.75 2.21921209e+00 -8.35908072e+00 8.64864919e+00 -1.31129730 0.77281668 468.00 -5.39616321e-01 -9.98541082e+00 9.99998075e+00 -1.62478429 0.83770070 468.25 -3.05606050e+00 -1.14766501e+01 1.18765737e+01 -1.83104242 0.91627086 468.50 -6.23703634e+00 -1.17488677e+01 1.33017486e+01 -2.05882822 0.92272773 468.75 -9.65344433e+00 -1.21536185e+01 1.55209352e+01 -2.24204316 0.95100060 469.00 -1.21581789e+01 -1.04915120e+01 1.60590516e+01 -2.42964664 0.94082785 469.25 -1.45838601e+01 -8.59037164e+00 1.69258223e+01 -2.60927632 0.95950671 469.50 -1.48865127e+01 -5.91806033e+00 1.60197284e+01 -2.76320435 0.95181290 469.75 -1.48664281e+01 -3.87922841e+00 1.53642149e+01 -2.88634541 0.96817516 470.00 -1.48016961e+01 -2.24758802e+00 1.49713680e+01 -2.99089718 0.95893296 470.25 -1.41964449e+01 -1.59608942e+00 1.42858863e+01 -3.02963399 0.96471481 470.50 -1.32534008e+01 -1.22274680e+00 1.33096860e+01 -3.04959399 0.94657407 470.75 -1.29262357e+01 -7.02125992e-01 1.29452907e+01 -3.08732808 0.95925974 471.00 -1.24129057e+01 -5.04296291e-01 1.24231455e+01 -3.10098821 0.95018413 471.25 -1.20893633e+01 -3.38055250e-01 1.20940889e+01 -3.11363691 0.95372200 471.50 -1.16230412e+01 -8.47559488e-01 1.16539025e+01 -3.06880086 0.93181764 471.75 -1.13736046e+01 -8.12718464e-01 1.14026046e+01 -3.07025736 0.92377185 472.00 -1.17398369e+01 -8.13296470e-01 1.17679744e+01 -3.07242652 0.89269884 472.25 -1.17121534e+01 -8.61874850e-01 1.17438224e+01 -3.06813698 0.88315669 472.50 -1.09453723e+01 -4.88931072e-01 1.09562871e+01 -3.09695221 0.85020284 472.75 -1.05165264e+01 -9.96539698e-01 1.05636366e+01 -3.04711536 0.85840670 473.00 -1.13648468e+01 -1.81323012e+00 1.15085858e+01 -2.98337887 0.87126454 473.25 -1.15363795e+01 -2.89638520e+00 1.18944147e+01 -2.89561156 0.87934428 473.50 -1.34434324e+01 -4.01807236e+00 1.40310648e+01 -2.85115692 0.91530451 473.75 -1.42151964e+01 -3.97416476e+00 1.47602775e+01 -2.86898128 0.93028728 474.00 -1.57133553e+01 -3.81411147e+00 1.61696314e+01 -2.90346744 0.92652198 474.25 -1.71891857e+01 -3.54293932e+00 1.75505135e+01 -2.93832480 0.91424684 474.50 -1.95244468e+01 -2.63970793e+00 1.97020832e+01 -3.00720737 0.93538904 474.75 -2.00546187e+01 -1.12848743e+00 2.00863440e+01 -3.08538123 0.93058623 475.00 -2.26770595e+01 7.41758909e-01 2.26891876e+01 3.10889465 0.91494184 475.25 -2.27332259e+01 2.71819968e+00 2.28951560e+01 3.02258817 0.89356871 475.50 -2.35250758e+01 7.22302136e+00 2.46089664e+01 2.84369430 0.87772001 475.75 -2.22270514e+01 1.16404827e+01 2.50906885e+01 2.65915909 0.82398022 476.00 -1.97265435e+01 1.67965547e+01 2.59087006e+01 2.43624595 0.86299331 476.25 -1.55566463e+01 1.75186876e+01 2.34289065e+01 2.29694355 0.82763714 476.50 -7.66516088e+00 1.74559762e+01 1.90647789e+01 1.98456054 0.82376327 476.75 -4.45585311e+00 1.51038955e+01 1.57474534e+01 1.85767210 0.74762337 477.00 -1.93283819e-01 1.05831092e+01 1.05848740e+01 1.58905772 0.70469190 477.25 1.47911439e+00 7.90466190e+00 8.04185670e+00 1.38581622 0.60572063 477.50 1.76143354e+00 4.53333223e+00 4.86351203e+00 1.20019804 0.52555779 477.75 1.55350023e+00 2.98835071e+00 3.36802656e+00 1.09139351 0.37248721 478.00 1.55429840e+00 1.07300716e+00 1.88870005e+00 0.60421886 0.19828503 478.25 2.33087838e+00 -1.38485758e-02 2.33091952e+00 -0.00594129 0.20526152 478.50 4.24688950e+00 -1.78154320e+00 4.60542795e+00 -0.39719750 0.52309803 478.75 6.22423902e+00 -3.16495945e+00 6.98270146e+00 -0.47041603 0.61999448 479.00 9.25630132e+00 -4.88201137e+00 1.04648530e+01 -0.48534669 0.76247427 479.25 1.24608890e+01 -5.49116554e+00 1.36171456e+01 -0.41506978 0.66400791 479.50 1.75408097e+01 -5.34182481e+00 1.83361691e+01 -0.29561393 0.75103884 479.75 2.08696003e+01 -2.65260297e-01 2.08712860e+01 -0.01270968 0.68464376 480.00 2.25826605e+01 5.37662285e+00 2.32138887e+01 0.23373475 0.72474798 480.25 1.68364399e+01 1.00746847e+01 1.96205244e+01 0.53923166 0.63496717 480.50 1.31659202e+01 1.46146998e+01 1.96705594e+01 0.83750169 0.71603726 480.75 6.32691293e+00 1.58823209e+01 1.70961382e+01 1.19170283 0.81120804 481.00 2.90878621e+00 1.52936904e+01 1.55678516e+01 1.38284601 0.87477405 481.25 -2.19213668e+00 1.49866784e+01 1.51461544e+01 1.71603867 0.87837086 481.50 -5.28727455e+00 1.44049827e+01 1.53446667e+01 1.92257444 0.92432725 481.75 -8.47801252e+00 1.41561664e+01 1.65007195e+01 2.11040060 0.92697496 482.00 -1.04369135e+01 1.46619146e+01 1.79972471e+01 2.18942340 0.94188990 482.25 -1.24733291e+01 1.46212163e+01 1.92188425e+01 2.27708614 0.92691397 482.50 -1.40270717e+01 1.53392052e+01 2.07858114e+01 2.31154255 0.94365040 482.75 -1.57238174e+01 1.67427533e+01 2.29686356e+01 2.32482063 0.91726237 483.00 -1.72056023e+01 1.89550292e+01 2.55993337e+01 2.30785286 0.92618780 483.25 -1.68348631e+01 1.95068390e+01 2.57668272e+01 2.28280286 0.90558270 483.50 -1.61285699e+01 2.04840178e+01 2.60715506e+01 2.23779054 0.86001708 483.75 -1.34782549e+01 2.90390804e+01 3.20145521e+01 2.00534825 0.82657892 484.00 -1.10542585e+01 3.47983624e+01 3.65119522e+01 1.87838069 0.81349953 484.25 -3.38102311e-01 3.77181320e+01 3.77196473e+01 1.57976001 0.76777179 484.50 8.35181713e+00 3.13131809e+01 3.24078408e+01 1.31014517 0.77465810 484.75 1.31457491e+01 2.02077659e+01 2.41073541e+01 0.99404892 0.89141856 485.00 1.21802920e+01 1.66351841e+01 2.06176832e+01 0.93878448 0.91204419 485.25 8.51718211e+00 1.17938646e+01 1.45477707e+01 0.94534522 0.90477716 485.50 6.15726270e+00 1.06742423e+01 1.23227972e+01 1.04758506 0.90365172 485.75 2.38574417e+00 9.77050883e+00 1.00575652e+01 1.33130457 0.92584820 486.00 9.65543054e-01 9.70980781e+00 9.75769650e+00 1.47168218 0.92814473 486.25 -1.45443330e+00 9.88507652e+00 9.99150209e+00 1.71688241 0.95912757 486.50 -2.38576878e+00 1.00369941e+01 1.03166440e+01 1.80416311 0.96194166 486.75 -3.92726384e+00 1.10034107e+01 1.16832551e+01 1.91361668 0.97017048 487.00 -4.64884411e+00 1.19168911e+01 1.27915615e+01 1.94274392 0.97255206 487.25 -5.35554385e+00 1.32262213e+01 1.42693651e+01 1.95553573 0.98255255 487.50 -5.58069658e+00 1.46337859e+01 1.56617964e+01 1.93512857 0.98258294 487.75 -5.70726683e+00 1.63185021e+01 1.72877530e+01 1.90724135 0.98799395 488.00 -5.12640030e+00 1.75301657e+01 1.82643557e+01 1.85529661 0.98213274 488.25 -3.56545859e+00 1.95728043e+01 1.98949029e+01 1.75098447 0.98454455 488.50 -1.15780759e+00 2.04015340e+01 2.04343610e+01 1.62748653 0.98642974 488.75 9.23294968e-01 1.94437074e+01 1.94656166e+01 1.52334643 0.98986321 489.00 1.29032682e+00 1.83625184e+01 1.84077980e+01 1.50064204 0.98919316 489.25 1.53594746e+00 1.71554152e+01 1.72240357e+01 1.48150306 0.99234771 489.50 1.86051095e+00 1.63432204e+01 1.64487797e+01 1.45744439 0.99007298 489.75 1.80267100e+00 1.55987181e+01 1.57025357e+01 1.45574138 0.98770707 490.00 7.37203828e-01 1.56628376e+01 1.56801770e+01 1.52376397 0.98310090 490.25 1.41272066e-01 1.63942401e+01 1.63948488e+01 1.56217936 0.98832312 490.50 1.06609385e+00 1.68689280e+01 1.69025823e+01 1.50768159 0.98715806 490.75 2.12572545e+00 1.71656638e+01 1.72967836e+01 1.44758768 0.99060526 491.00 3.16602232e+00 1.71095926e+01 1.74000534e+01 1.38782231 0.98853726 491.25 3.64615318e+00 1.66481465e+01 1.70427467e+01 1.35518807 0.98966532 491.50 3.28227104e+00 1.64302051e+01 1.67548483e+01 1.37362141 0.98593281 491.75 3.30521017e+00 1.66413663e+01 1.69664224e+01 1.37473371 0.98601266 492.00 4.38684857e+00 1.67153801e+01 1.72814459e+01 1.31414053 0.98535342 492.25 4.53365630e+00 1.66877512e+01 1.72926308e+01 1.30552332 0.98895499 492.50 4.61002151e+00 1.65807488e+01 1.72096929e+01 1.29961109 0.98513647 492.75 4.55960059e+00 1.65865308e+01 1.72018302e+01 1.30252515 0.98118266 493.00 4.52800309e+00 1.70817955e+01 1.76717443e+01 1.31167799 0.97137368 493.25 4.77643897e+00 1.79104673e+01 1.85364292e+01 1.31017755 0.96887661 493.50 5.44462762e+00 1.95709932e+01 2.03142252e+01 1.29945862 0.96172590 493.75 6.09007356e+00 2.00757395e+01 2.09791400e+01 1.27626451 0.95407069 494.00 8.26699862e+00 2.10905246e+01 2.26528915e+01 1.19722549 0.94570225 494.25 1.01101234e+01 2.14690659e+01 2.37304737e+01 1.13068556 0.94440310 494.50 1.23898782e+01 2.24290031e+01 2.56236075e+01 1.06610906 0.94164421 494.75 1.39945323e+01 2.23449310e+01 2.63655623e+01 1.01126587 0.94369891 495.00 1.81841698e+01 2.20309811e+01 2.85662066e+01 0.88076378 0.92185703 495.25 1.99230536e+01 2.18611099e+01 2.95776299e+01 0.83174750 0.91471364 495.50 2.46197644e+01 1.97946332e+01 3.15905097e+01 0.67718366 0.93032521 495.75 2.77574349e+01 1.72328767e+01 3.26718110e+01 0.55560098 0.91206866 496.00 3.19540024e+01 1.01910526e+01 3.35397648e+01 0.30873097 0.87205833 496.25 3.36127543e+01 5.34850894e+00 3.40356255e+01 0.15779849 0.87323800 496.50 3.16754617e+01 -1.02572455e+00 3.16920651e+01 -0.03237100 0.86373320 496.75 2.68372406e+01 -4.22361815e+00 2.71675622e+01 -0.15609865 0.86613920 497.00 2.52821500e+01 -7.27640183e+00 2.63084232e+01 -0.28023417 0.94011311 497.25 2.49631211e+01 -6.97099304e+00 2.59181820e+01 -0.27231463 0.94152162 497.50 2.44570617e+01 -8.04447929e+00 2.57460970e+01 -0.31777562 0.93844784 497.75 2.41180835e+01 -9.35951526e+00 2.58704943e+01 -0.37018016 0.92337330 498.00 2.25657671e+01 -1.19007095e+01 2.55115803e+01 -0.48531007 0.92504910 498.25 2.14597274e+01 -1.47425041e+01 2.60357702e+01 -0.60193734 0.89549911 498.50 1.88839593e+01 -1.99833510e+01 2.74943310e+01 -0.81367639 0.88219964 498.75 1.43733287e+01 -2.25622685e+01 2.67516081e+01 -1.00357761 0.85616095 499.00 7.91498369e+00 -2.19631372e+01 2.33457997e+01 -1.22490808 0.88586970 499.25 3.74614917e+00 -2.01096378e+01 2.04555901e+01 -1.38662116 0.87693013 499.50 1.00966586e+00 -1.83141005e+01 1.83419110e+01 -1.51572156 0.89793517 499.75 -5.64142806e-01 -1.60600637e+01 1.60699690e+01 -1.60590895 0.86682833 500.00 -1.83042956e+00 -1.37232650e+01 1.38447996e+01 -1.70339518 0.84824893 500.25 -2.01330128e+00 -1.08076445e+01 1.09935691e+01 -1.75497021 0.82550293 500.50 -2.24233815e+00 -9.59471413e+00 9.85325426e+00 -1.80038125 0.89088359 500.75 -1.98178294e+00 -8.67160953e+00 8.89518271e+00 -1.79547470 0.87657673 501.00 -1.62961802e+00 -8.30737763e+00 8.46570600e+00 -1.76450183 0.90073013 501.25 -1.79683409e+00 -7.95345844e+00 8.15390176e+00 -1.79298492 0.82167430 501.50 -2.94006820e+00 -8.03546002e+00 8.55643727e+00 -1.92155344 0.79688472 501.75 -3.56977676e+00 -7.37999758e+00 8.19802845e+00 -2.02132701 0.74242906 502.00 -4.20131345e+00 -6.39814692e+00 7.65423534e+00 -2.15182897 0.70798561 502.25 -4.66301500e+00 -5.27538507e+00 7.04083777e+00 -2.29465573 0.64402670 502.50 -4.89584967e+00 -3.96742266e+00 6.30157016e+00 -2.46056378 0.61273753 502.75 -4.08135062e+00 -1.78270753e+00 4.45370285e+00 -2.72977534 0.33205279 503.00 -4.06523302e+00 -3.18698653e-01 4.07770626e+00 -3.06335651 0.25622603 503.25 -2.55640782e+00 1.15318994e+00 2.80447285e+00 2.71782617 0.12559143 503.50 -1.93020467e+00 2.45848961e+00 3.12567772e+00 2.23639683 0.16739637 503.75 1.35322406e+00 2.31758815e+00 2.68373437e+00 1.04230423 0.13365124 504.00 1.98552058e+00 2.63916088e+00 3.30264471e+00 0.92580552 0.16782639 504.25 3.32365063e+00 2.05202712e+00 3.90608100e+00 0.55311661 0.29214129 504.50 3.64135161e+00 2.13500688e+00 4.22110127e+00 0.53030191 0.36074897 504.75 3.58914190e+00 3.80531486e+00 5.23090439e+00 0.81462430 0.26623104 505.00 5.99938116e+00 4.57743272e+00 7.54622188e+00 0.65175931 0.34300083 505.25 9.02602219e+00 -2.09514501e+00 9.26599747e+00 -0.22808354 0.29048659 505.50 1.03027760e+01 -6.63009439e+00 1.22517486e+01 -0.57180993 0.47979548 505.75 9.63695554e+00 -1.13611979e+01 1.48979103e+01 -0.86732835 0.65105659 506.00 7.52764364e+00 -1.40974543e+01 1.59813527e+01 -1.08034202 0.70985195 506.25 2.15424593e+00 -1.52628438e+01 1.54141226e+01 -1.43057938 0.78926306 506.50 3.99975038e-01 -1.48558647e+01 1.48612481e+01 -1.54387912 0.87673278 506.75 -1.16247293e+00 -1.28894609e+01 1.29417752e+01 -1.66074085 0.91201592 507.00 -1.36802817e+00 -1.22858952e+01 1.23618252e+01 -1.68168901 0.89179793 507.25 -4.97048294e-01 -1.32969531e+01 1.33062399e+01 -1.60815955 0.89674278 507.50 -1.40237596e+00 -1.35558128e+01 1.36281591e+01 -1.67388162 0.90054045 507.75 -4.08125762e+00 -1.33872124e+01 1.39955036e+01 -1.86670804 0.91638878 508.00 -5.80085461e+00 -1.19309422e+01 1.32663972e+01 -2.02334518 0.91007173 508.25 -6.93702201e+00 -1.02525794e+01 1.23789200e+01 -2.16565284 0.96015595 508.50 -6.84439933e+00 -9.06980302e+00 1.13625318e+01 -2.21725784 0.93920849 508.75 -6.58934149e+00 -7.42021485e+00 9.92365909e+00 -2.29695627 0.96438629 509.00 -6.53950953e+00 -6.96073231e+00 9.55075804e+00 -2.32500348 0.97372491 509.25 -6.29236475e+00 -6.45288844e+00 9.01296973e+00 -2.34360037 0.98213434 509.50 -5.88273941e+00 -6.00226257e+00 8.40439046e+00 -2.34613819 0.97264006 509.75 -5.47434504e+00 -5.57462453e+00 7.81312308e+00 -2.34711883 0.98005081 510.00 -5.26170512e+00 -5.35165259e+00 7.50504671e+00 -2.34771976 0.97605532 510.25 -5.15948705e+00 -5.14549114e+00 7.28672667e+00 -2.35755266 0.98197037 510.50 -5.01762973e+00 -5.15019923e+00 7.19035188e+00 -2.34315710 0.98213839 510.75 -4.93820696e+00 -5.13210882e+00 7.12210846e+00 -2.33694207 0.98705337 511.00 -5.08400881e+00 -4.82007451e+00 7.00573079e+00 -2.38283722 0.98307809 511.25 -5.10461660e+00 -4.56056835e+00 6.84513655e+00 -2.41242463 0.98663932 511.50 -4.94017090e+00 -4.22580681e+00 6.50097929e+00 -2.43397375 0.98674739 511.75 -4.85824487e+00 -4.01459932e+00 6.30234488e+00 -2.45099125 0.98823338 512.00 -4.58180597e+00 -3.66278319e+00 5.86591226e+00 -2.46720602 0.98663015 512.25 -4.37074563e+00 -3.56830093e+00 5.64235668e+00 -2.45692808 0.98784555 512.50 -3.97532484e+00 -3.50662271e+00 5.30090657e+00 -2.41875714 0.98533493 512.75 -3.73928017e+00 -3.49067445e+00 5.11537138e+00 -2.39056646 0.98971699 513.00 -3.43552944e+00 -3.44614206e+00 4.86608237e+00 -2.35465233 0.98691147 513.25 -3.28490880e+00 -3.37501931e+00 4.70971137e+00 -2.34266506 0.98518412 513.50 -3.07239650e+00 -3.53254156e+00 4.68171658e+00 -2.28664005 0.98038949 513.75 -3.00804442e+00 -3.64913999e+00 4.72911767e+00 -2.26018923 0.98316772 514.00 -2.87474557e+00 -3.77982068e+00 4.74881106e+00 -2.22101581 0.97301486 514.25 -2.70000053e+00 -3.78946479e+00 4.65296102e+00 -2.18986358 0.96986091 514.50 -2.51786293e+00 -3.92029209e+00 4.65921923e+00 -2.14171408 0.97009282 514.75 -2.52009315e+00 -3.88730277e+00 4.63270896e+00 -2.14596735 0.96780463 515.00 -2.50645525e+00 -3.71683087e+00 4.48298445e+00 -2.16410123 0.95515784 515.25 -2.27466392e+00 -3.57975945e+00 4.24131745e+00 -2.13685623 0.95504590 515.50 -2.09495598e+00 -3.23104849e+00 3.85078108e+00 -2.14603377 0.95752023 515.75 -1.99085366e+00 -3.16452404e+00 3.73867767e+00 -2.13235020 0.95045394 516.00 -1.62728897e+00 -2.98469583e+00 3.39948210e+00 -2.06995532 0.92063955 516.25 -1.28616599e+00 -2.77873859e+00 3.06196197e+00 -2.00429274 0.86727426 516.50 -2.27820036e-02 -2.93585050e+00 2.93593889e+00 -1.57855610 0.76427460 516.75 6.69248159e-01 -3.11169098e+00 3.18284682e+00 -1.35894811 0.79474339 517.00 1.40296479e+00 -3.73856544e+00 3.99314184e+00 -1.21179053 0.86849832 517.25 2.00924044e+00 -4.08373883e+00 4.55126026e+00 -1.11356110 0.90186644 517.50 2.60842562e+00 -4.87642041e+00 5.53022244e+00 -1.07961555 0.88633916 517.75 2.77810843e+00 -5.83874088e+00 6.46597104e+00 -1.12669050 0.84944602 518.00 1.25543419e+00 -8.67414011e+00 8.76452061e+00 -1.42706143 0.86339717 518.25 -1.90560470e-01 -8.41364325e+00 8.41580098e+00 -1.59344144 0.85378815 518.50 -1.76446624e+00 -6.22878731e+00 6.47388079e+00 -1.84684032 0.82243144 518.75 -9.63655076e-01 -5.17176298e+00 5.26077594e+00 -1.75501386 0.83238109 519.00 1.89662908e-01 -5.16723509e+00 5.17071470e+00 -1.53410789 0.91260521 519.25 6.25810976e-01 -5.08562947e+00 5.12398931e+00 -1.44835709 0.88894651 519.50 1.23653665e+00 -5.38124869e+00 5.52149077e+00 -1.34493101 0.90392704 519.75 1.34080116e+00 -5.67567546e+00 5.83189846e+00 -1.33881299 0.91456533 520.00 1.47976402e+00 -5.57009205e+00 5.76330001e+00 -1.31113176 0.93463953 520.25 1.85346921e+00 -5.35465620e+00 5.66636489e+00 -1.23756297 0.92753713 520.50 2.11557606e+00 -5.11866536e+00 5.53862772e+00 -1.17887199 0.92546743 520.75 2.40047175e+00 -5.07454021e+00 5.61366395e+00 -1.12894658 0.93261430 521.00 2.65723445e+00 -4.90765651e+00 5.58085902e+00 -1.07454365 0.93658203 521.25 3.37681283e+00 -4.48823342e+00 5.61668088e+00 -0.92578005 0.90872194 521.50 4.43420942e+00 -4.17849449e+00 6.09278502e+00 -0.75571645 0.93129147 521.75 5.32249801e+00 -3.91470745e+00 6.60711128e+00 -0.63415758 0.92936567 522.00 6.29928571e+00 -4.04733416e+00 7.48745045e+00 -0.57108957 0.96163298 522.25 7.00209026e+00 -4.15757778e+00 8.14338510e+00 -0.53582039 0.95512155 522.50 7.97764024e+00 -4.19179138e+00 9.01187321e+00 -0.48379384 0.95169183 522.75 9.57340158e+00 -4.54121265e+00 1.05958780e+01 -0.44292380 0.96563520 523.00 1.03847132e+01 -4.83232474e+00 1.14539788e+01 -0.43552946 0.97397832 523.25 1.11097991e+01 -5.64512542e+00 1.24617446e+01 -0.47012351 0.96419320 523.50 1.10750682e+01 -6.28292891e+00 1.27331195e+01 -0.51603119 0.96896360 523.75 1.12395787e+01 -5.69763606e+00 1.26012375e+01 -0.46917314 0.97559248 524.00 1.19984349e+01 -5.74520814e+00 1.33030018e+01 -0.44656846 0.98504257 524.25 1.28304266e+01 -6.40419617e+00 1.43399294e+01 -0.46296043 0.97705706 524.50 1.32333822e+01 -7.04245436e+00 1.49906160e+01 -0.48905385 0.96850235 524.75 1.23327397e+01 -8.59937132e+00 1.50348147e+01 -0.60889805 0.92745875 525.00 1.04672202e+01 -8.48072124e+00 1.34716491e+01 -0.68093993 0.93180165 525.25 1.00980483e+01 -6.14151181e+00 1.18189994e+01 -0.54641835 0.96566253 525.50 1.04733940e+01 -5.33784245e+00 1.17551922e+01 -0.47134362 0.97915342 525.75 1.09642822e+01 -4.73335497e+00 1.19423672e+01 -0.40753761 0.98842826 526.00 1.08802511e+01 -4.48890860e+00 1.17698838e+01 -0.39129881 0.98630086 526.25 1.06421801e+01 -3.89820507e+00 1.13336667e+01 -0.35111943 0.97634900 526.50 1.03647359e+01 -3.79737424e+00 1.10384692e+01 -0.35118717 0.97646757 526.75 9.93327025e+00 -3.38684218e+00 1.04947872e+01 -0.32859827 0.97345129 527.00 9.57579401e+00 -3.11107454e+00 1.00684962e+01 -0.31413192 0.96953308 527.25 8.65102937e+00 -2.47471177e+00 8.99802798e+00 -0.27861907 0.96888323 527.50 8.31097387e+00 -2.12298466e+00 8.57784067e+00 -0.25009540 0.96227821 527.75 7.42511957e+00 -1.71634360e+00 7.62090782e+00 -0.22716381 0.96650962 528.00 6.88138495e+00 -1.70041820e+00 7.08836236e+00 -0.24225123 0.95677596 528.25 5.97898215e+00 -1.62480784e+00 6.19582343e+00 -0.26534524 0.95845618 528.50 5.45208200e+00 -1.39023484e+00 5.62653989e+00 -0.24967105 0.94928670 528.75 4.70355881e+00 -1.21729620e+00 4.85852607e+00 -0.25324674 0.93782421 529.00 3.91413994e+00 -1.12019179e+00 4.07128003e+00 -0.27874038 0.87465654 529.25 2.72119214e+00 -7.43966202e-01 2.82105873e+00 -0.26687545 0.80124515 529.50 2.44491549e+00 -2.05286401e-01 2.45351875e+00 -0.08376813 0.63866555 529.75 1.60963324e+00 7.50451507e-01 1.77597766e+00 0.43626454 0.45106034 530.00 1.81844725e+00 6.23488729e-01 1.92236536e+00 0.33030774 0.54319239 530.25 1.75865396e+00 2.77020446e-01 1.78033819e+00 0.15623472 0.58979810 530.50 1.26793178e+00 1.51214135e-01 1.27691687e+00 0.11869983 0.44083338 530.75 7.56173520e-01 7.10287853e-02 7.59502127e-01 0.09365705 0.26753764 531.00 5.36465766e-01 -3.97907514e-02 5.37939423e-01 -0.07403645 0.15771081 531.25 4.15742737e-01 -1.30070979e-01 4.35615063e-01 -0.30321654 0.12762088 531.50 1.20782076e-01 -3.87671156e-01 4.06050779e-01 -1.26876982 0.08422517 531.75 -3.29175833e-01 -6.27695559e-01 7.08772491e-01 -2.05378820 0.22555835 532.00 -7.50734997e-01 -9.86511444e-01 1.23968055e+00 -2.22130021 0.42533715 532.25 -1.31389516e+00 -1.26800493e+00 1.82596742e+00 -2.37396644 0.62747908 532.50 -1.82113553e+00 -1.54326368e+00 2.38708974e+00 -2.43859928 0.60080128 532.75 -2.30452358e+00 -1.51674526e+00 2.75886664e+00 -2.55950242 0.64111211 533.00 -2.33280810e+00 -1.29019877e+00 2.66582192e+00 -2.63639793 0.61190269 533.25 -2.31507530e+00 -1.41277663e+00 2.71210462e+00 -2.59366985 0.65138862 533.50 -2.19107369e+00 -1.30772178e+00 2.55165439e+00 -2.60349947 0.43004446 533.75 -2.10092554e+00 -1.26296849e+00 2.45132159e+00 -2.60032901 0.44566348 534.00 -2.19117136e+00 -1.14596252e+00 2.47274383e+00 -2.65972200 0.33412041 534.25 -2.74291151e+00 -8.30996184e-01 2.86602830e+00 -2.84742124 0.38872347 534.50 -3.03995133e+00 -2.53595674e-01 3.05051059e+00 -3.05836439 0.46000636 534.75 -2.68424156e+00 2.81605072e-01 2.69897280e+00 3.03706454 0.41601033 535.00 -1.50893174e+00 3.57491056e-01 1.55070141e+00 2.90896513 0.19887684 535.25 -1.43070347e+00 4.89023814e-01 1.51197113e+00 2.81223569 0.21891927 535.50 -1.54076228e+00 5.98162649e-01 1.65279973e+00 2.77127805 0.25294406 535.75 -1.32555962e+00 5.34698387e-01 1.42933925e+00 2.75817968 0.21996683 536.00 -7.67513870e-01 2.17034111e-01 7.97609770e-01 2.86601210 0.10271313 536.25 -8.21856124e-01 3.36192712e-02 8.22543461e-01 3.10070893 0.11223448 536.50 -7.40357307e-01 -7.25862145e-01 1.03682438e+00 -2.36608025 0.18066527 536.75 -8.06120649e-01 -7.68912100e-01 1.11402707e+00 -2.37981408 0.19391826 537.00 -1.17860017e+00 -8.48472278e-01 1.45224088e+00 -2.51763657 0.26559056 537.25 -1.42178299e+00 -1.22095238e+00 1.87408420e+00 -2.43204217 0.33512901 537.50 -2.33845483e+00 -1.69373070e+00 2.88740275e+00 -2.51474685 0.41607551 537.75 -3.18134205e+00 -1.83668595e+00 3.67346600e+00 -2.61800867 0.39590316 538.00 -5.75343789e+00 -8.89481762e-02 5.75412542e+00 -3.12613388 0.45193585 538.25 -6.75882569e+00 1.81832895e+00 6.99914601e+00 2.87878485 0.47067373 538.50 -6.99978531e+00 5.55269458e+00 8.93473063e+00 2.47097107 0.39462578 538.75 -6.18821582e+00 7.17010439e+00 9.47124131e+00 2.28282254 0.35751901 539.00 -5.38951099e+00 1.25564417e+01 1.36642254e+01 1.97623828 0.39451167 539.25 -2.52347819e+00 1.30628611e+01 1.33043708e+01 1.76162528 0.32715492 539.50 -1.35634758e+00 1.53871134e+01 1.54467776e+01 1.65871736 0.38607648 539.75 -1.67031121e+00 1.30693154e+01 1.31756193e+01 1.69791126 0.26306361 540.00 1.35732813e+00 1.46452382e+01 1.47080027e+01 1.47837982 0.22909035 540.25 2.41352764e+00 1.58027868e+01 1.59860310e+01 1.41923951 0.19597433 540.50 4.76488765e+00 8.23882276e+00 9.51747628e+00 1.04645131 0.06934380 540.75 9.85078981e+00 -5.33918491e+00 1.12046845e+01 -0.49668490 0.10095934 541.00 1.86450267e+01 -1.52044284e+01 2.40585050e+01 -0.68410193 0.40781705 541.25 2.18431548e+01 -1.83326933e+01 2.85168556e+01 -0.69824211 0.60415460 541.50 2.06719933e+01 -1.64607893e+01 2.64251565e+01 -0.67247133 0.64963937 541.75 2.00314148e+01 -1.33598001e+01 2.40778288e+01 -0.58819348 0.71288645 542.00 2.18507726e+01 -1.07232084e+01 2.43401615e+01 -0.45621811 0.73502307 542.25 2.37449559e+01 -9.86526826e+00 2.57127682e+01 -0.39376930 0.75306547 542.50 2.63153372e+01 -7.05653616e+00 2.72450302e+01 -0.26198952 0.78669950 542.75 2.80452442e+01 -4.20276408e+00 2.83584017e+01 -0.14874967 0.73485578 543.00 2.98470740e+01 -3.20233517e+00 3.00183740e+01 -0.10688255 0.73444760 543.25 3.15024023e+01 -2.99563105e+00 3.16445122e+01 -0.09480707 0.71611789 543.50 3.37069418e+01 -1.24017826e+00 3.37297490e+01 -0.03677637 0.65019494 543.75 3.31718859e+01 -2.57809085e+00 3.32719186e+01 -0.07756324 0.49387415 544.00 3.30196656e+01 -4.04689567e+00 3.32667353e+01 -0.12195198 0.46386444 544.25 3.11013585e+01 -5.69622000e+00 3.16186879e+01 -0.18114259 0.28736500 544.50 2.72945221e+01 -1.85597043e+01 3.30068714e+01 -0.59716236 0.24156677 544.75 2.15998576e+01 -2.59008811e+01 3.37255021e+01 -0.87569838 0.20587095 545.00 2.11644900e+01 -2.96402335e+01 3.64208605e+01 -0.95070559 0.23646147 545.25 1.22051390e+01 -3.57180976e+01 3.77458331e+01 -1.24152812 0.18732580 545.50 -1.37855421e+00 -4.09009802e+01 4.09242055e+01 -1.60448825 0.23823310 545.75 -8.25097803e+00 -4.29469999e+01 4.37324072e+01 -1.76060362 0.29827495 546.00 -1.89042472e+01 -4.23335830e+01 4.63627308e+01 -1.99078119 0.38749110 546.25 -2.50896002e+01 -3.68458816e+01 4.45769787e+01 -2.16861114 0.54312497 546.50 -2.85398621e+01 -3.66203796e+01 4.64281803e+01 -2.23281444 0.68452213 546.75 -3.09642516e+01 -2.81871504e+01 4.18724292e+01 -2.40310908 0.76388901 547.00 -2.97462629e+01 -2.66778623e+01 3.99568329e+01 -2.41052198 0.79462653 547.25 -2.93011985e+01 -2.01095556e+01 3.55380706e+01 -2.54011730 0.80129806 547.50 -2.92693633e+01 -1.62091866e+01 3.34579341e+01 -2.63584154 0.82623278 547.75 -2.45443985e+01 -1.34894627e+01 2.80070188e+01 -2.63906094 0.84269611 548.00 -2.03320478e+01 -1.24070561e+01 2.38186315e+01 -2.59369110 0.86054025 548.25 -1.54500008e+01 -1.05898152e+01 1.87309026e+01 -2.54071576 0.92777399 548.50 -1.35426668e+01 -1.06424715e+01 1.72239956e+01 -2.47554102 0.94223661 548.75 -1.08589813e+01 -1.17464563e+01 1.59967719e+01 -2.31695528 0.95523949 549.00 -9.99953492e+00 -1.17805391e+01 1.54522426e+01 -2.27460384 0.96177073 549.25 -8.52660260e+00 -1.17632499e+01 1.45284893e+01 -2.19800680 0.96454668 549.50 -7.62795018e+00 -1.15701393e+01 1.38583458e+01 -2.15366696 0.95535123 549.75 -6.68908796e+00 -1.08980781e+01 1.27871812e+01 -2.12129098 0.95539674 550.00 -5.72882439e+00 -1.08658012e+01 1.22835282e+01 -2.05599335 0.94828062 550.25 -4.20204664e+00 -1.10352213e+01 1.18081880e+01 -1.93462910 0.95542099 550.50 -3.84121064e+00 -1.17924992e+01 1.24023359e+01 -1.88569140 0.94733146 550.75 -2.97474650e+00 -1.24629174e+01 1.28130179e+01 -1.80510022 0.94810577 551.00 -2.64552922e+00 -1.27573020e+01 1.30287213e+01 -1.77527185 0.94865210 551.25 -2.36828847e+00 -1.25239530e+01 1.27459088e+01 -1.75769018 0.94398171 551.50 -2.12907611e+00 -1.28548725e+01 1.30299928e+01 -1.73493040 0.91502302 551.75 -2.48931941e+00 -1.30068164e+01 1.32428842e+01 -1.75989541 0.89536029 552.00 -2.78298999e+00 -1.32481741e+01 1.35373243e+01 -1.77785166 0.86692247 552.25 -2.39298361e+00 -1.49689298e+01 1.51589984e+01 -1.72931837 0.90405799 552.50 -1.57953705e+00 -1.43827212e+01 1.44691951e+01 -1.68017983 0.87699472 552.75 -1.97583952e+00 -1.39703558e+01 1.41093863e+01 -1.71129535 0.86096314 553.00 -2.29607041e+00 -1.41235142e+01 1.43089340e+01 -1.73195717 0.82843845 553.25 -2.06535136e+00 -1.58784767e+01 1.60122359e+01 -1.70014251 0.83861824 553.50 -2.25483719e+00 -1.59278946e+01 1.60867063e+01 -1.71142715 0.78001912 553.75 -1.59711377e+00 -1.57522523e+01 1.58330106e+01 -1.67184058 0.75895125 554.00 1.04224693e-01 -1.73225039e+01 1.73228175e+01 -1.56477968 0.72444171 554.25 -6.54575712e-01 -1.95184791e+01 1.95294520e+01 -1.60431997 0.68389737 554.50 -2.33949696e+00 -2.18709962e+01 2.19957660e+01 -1.67735913 0.57646381 554.75 -1.78714046e+00 -2.02721838e+01 2.03508061e+01 -1.65872628 0.45012094 555.00 -6.14457939e+00 -1.33257955e+01 1.46742183e+01 -2.00284599 0.17049648 555.25 -9.81053683e+00 -8.04921419e+00 1.26900151e+01 -2.45449629 0.09126365 555.50 -1.23783114e+01 3.28855601e+00 1.28077005e+01 2.88192023 0.10287249 555.75 -1.48969031e+01 1.07979214e+01 1.83987181e+01 2.51438713 0.20684196 556.00 -7.62361683e+00 1.59273923e+01 1.76578979e+01 2.01721701 0.40276222 556.25 -4.97537686e+00 1.48955153e+01 1.57044818e+01 1.89316336 0.51826022 556.50 -2.08849218e+00 1.13718596e+01 1.15620496e+01 1.75242672 0.57843133 556.75 -2.75192870e+00 9.77718331e+00 1.01570874e+01 1.84516242 0.60463894 557.00 -2.72264675e+00 6.76849689e+00 7.29557095e+00 1.95324325 0.58624333 557.25 -3.03512693e+00 5.74837984e+00 6.50045123e+00 2.05658981 0.59686450 557.50 -3.74174991e+00 4.48545785e+00 5.84123484e+00 2.26604336 0.69508257 557.75 -4.28255054e+00 3.71571341e+00 5.66981175e+00 2.42694622 0.72511422 558.00 -5.44106513e+00 2.55104996e+00 6.00941309e+00 2.70317312 0.82123917 558.25 -5.82937344e+00 2.26449971e+00 6.25376316e+00 2.77107079 0.80974467 558.50 -6.53528680e+00 1.92237236e+00 6.81215744e+00 2.85550894 0.84353512 558.75 -6.40711812e+00 1.47603412e+00 6.57494025e+00 2.91516898 0.81545824 559.00 -5.94357393e+00 5.88063390e-01 5.97259489e+00 3.04297259 0.77508796 559.25 -6.51913221e+00 4.92409538e-01 6.53770234e+00 3.06620282 0.80239004 559.50 -7.15988366e+00 -2.14768142e-01 7.16310403e+00 -3.11160561 0.83115719 559.75 -6.68907682e+00 -6.57953570e-01 6.72135787e+00 -3.04354566 0.78023480 560.00 -6.54149497e+00 -1.61549527e+00 6.73802504e+00 -2.89947610 0.79135790 560.25 -6.62934427e+00 -1.72516104e+00 6.85013766e+00 -2.88700821 0.76936600 560.50 -5.73733402e+00 -1.86325386e+00 6.03230608e+00 -2.82757827 0.75136091 560.75 -5.57797287e+00 -2.33876970e+00 6.04843988e+00 -2.74457118 0.75139293 561.00 -4.98212519e+00 -2.56471752e+00 5.60351206e+00 -2.66618805 0.68907668 561.25 -4.01054447e+00 -2.93815210e+00 4.97164004e+00 -2.50931645 0.61133477 561.50 -2.68431836e+00 -3.42002178e+00 4.34765616e+00 -2.23625163 0.56601983 561.75 -1.86002484e+00 -4.51039583e+00 4.87886902e+00 -1.96193462 0.56331109 562.00 -1.25492636e+00 -5.25770827e+00 5.40539882e+00 -1.80509580 0.74295202 562.25 -9.33774843e-02 -6.01294019e+00 6.01366520e+00 -1.58632450 0.76697629 562.50 1.15549683e+00 -7.24733900e+00 7.33887563e+00 -1.41268968 0.85754336 562.75 1.87846244e+00 -8.05630321e+00 8.27240247e+00 -1.34172233 0.83929532 563.00 2.45629865e+00 -8.93369300e+00 9.26521849e+00 -1.30247871 0.82976841 563.25 2.22700726e+00 -1.01673513e+01 1.04083906e+01 -1.35516652 0.86027954 563.50 1.71966987e+00 -1.07917682e+01 1.09279241e+01 -1.41277476 0.91583596 563.75 2.15546167e+00 -1.11776290e+01 1.13835586e+01 -1.38029755 0.90455965 564.00 2.64563671e+00 -1.15067674e+01 1.18069933e+01 -1.34480386 0.89910075 564.25 3.53289317e+00 -1.25982505e+01 1.30842367e+01 -1.29739145 0.92318701 564.50 3.63254202e+00 -1.35131204e+01 1.39928476e+01 -1.30818844 0.94618059 564.75 3.13393391e+00 -1.59921389e+01 1.62963201e+01 -1.37728150 0.95434760 565.00 2.13495774e+00 -1.75161354e+01 1.76457656e+01 -1.44950937 0.94635763 565.25 -1.75255219e+00 -2.03551117e+01 2.04304188e+01 -1.65668339 0.94101732 565.50 -4.88748445e+00 -2.07819767e+01 2.13489592e+01 -1.80177791 0.94798210 565.75 -9.86160483e+00 -1.83233333e+01 2.08085509e+01 -2.06453437 0.93991695 566.00 -1.21549510e+01 -1.69725800e+01 2.08760941e+01 -2.19228066 0.95003045 566.25 -1.33412994e+01 -1.26034377e+01 1.83531172e+01 -2.38462657 0.93758690 566.50 -1.46894478e+01 -1.00826421e+01 1.78168333e+01 -2.54006166 0.94590440 566.75 -1.55499081e+01 -5.55225410e+00 1.65114254e+01 -2.79864198 0.95389446 567.00 -1.49782270e+01 -3.71128282e+00 1.54311666e+01 -2.89870589 0.94142760 567.25 -1.35287026e+01 -6.48152716e-01 1.35442200e+01 -3.09371981 0.91714335 567.50 -1.20218304e+01 1.45451849e+00 1.21095016e+01 3.02118812 0.88860144 567.75 -8.52873509e+00 4.02398252e+00 9.43036359e+00 2.70074645 0.87759065 568.00 -6.90881775e+00 4.38879514e+00 8.18494260e+00 2.57565971 0.84498497 568.25 -3.60533684e+00 4.59132675e+00 5.83769946e+00 2.23647810 0.77160713 568.50 -2.18224115e+00 4.41363772e+00 4.92365457e+00 2.02997915 0.72291086 568.75 5.57731905e-01 2.59382260e+00 2.65310772e+00 1.35899804 0.44343614 569.00 1.26214350e+00 1.63265159e+00 2.06362725e+00 0.91269717 0.33339802 569.25 1.83469151e+00 3.19286691e-01 1.86226661e+00 0.17230186 0.31371464 569.50 2.25415418e+00 -9.73148903e-01 2.45524538e+00 -0.40754331 0.39626497 569.75 2.24125770e+00 -2.91937812e+00 3.68048974e+00 -0.91605210 0.62787772 570.00 1.90473425e+00 -3.61336116e+00 4.08465316e+00 -1.08567600 0.60553810 570.25 3.09153691e-01 -4.73184852e+00 4.74193699e+00 -1.50555440 0.65075327 570.50 -4.95892822e-01 -4.87803486e+00 4.90317589e+00 -1.67210661 0.65031885 570.75 -1.44835277e+00 -5.20330591e+00 5.40112193e+00 -1.84227657 0.63240430 571.00 -2.36185370e+00 -4.66042623e+00 5.22474167e+00 -2.03986054 0.53244672 571.25 -3.63434324e+00 -3.67494890e+00 5.16852980e+00 -2.35063920 0.46690507 571.50 -5.22723459e+00 -2.37928378e+00 5.74325455e+00 -2.71444714 0.45529963 571.75 -6.27791400e+00 9.23094243e-02 6.27859261e+00 3.12688988 0.64830108 572.00 -5.44034033e+00 1.14152365e+00 5.55881094e+00 2.93476733 0.57983022 572.25 -4.41454445e+00 2.37282995e+00 5.01183845e+00 2.64839483 0.68443458 572.50 -3.54197421e+00 2.55211609e+00 4.36564747e+00 2.51721740 0.60515267 572.75 -2.41390666e+00 2.14459732e+00 3.22896935e+00 2.41520435 0.52336569 573.00 -1.58135257e+00 1.36363304e+00 2.08810225e+00 2.42998914 0.36559918 573.25 -1.53574313e+00 7.35974877e-01 1.70298737e+00 2.69469831 0.36662036 573.50 -2.82113820e+00 7.56871703e-01 2.92090320e+00 2.87947911 0.49315610 573.75 -3.76606626e+00 1.31742217e+00 3.98984414e+00 2.80508367 0.72103722 574.00 -3.87805434e+00 2.65188794e+00 4.69806503e+00 2.54180905 0.76931907 574.25 -3.11182351e+00 3.25883299e+00 4.50593364e+00 2.33312255 0.74188330 574.50 -1.23798790e+00 3.94834738e+00 4.13788123e+00 1.87463371 0.71257464 574.75 -8.39370293e-01 4.07151494e+00 4.15713560e+00 1.77410477 0.80825383 575.00 -1.19955820e+00 3.82020592e+00 4.00411203e+00 1.87505039 0.74132052 575.25 -1.80367673e+00 4.02480786e+00 4.41047935e+00 1.99210226 0.76277531 575.50 -2.53381936e+00 5.41686176e+00 5.98018661e+00 2.00832518 0.73605493 575.75 -3.06666207e+00 7.22409560e+00 7.84805539e+00 1.97224732 0.74228873 576.00 -5.69408267e+00 9.26128311e+00 1.08717037e+01 2.12204643 0.47462095 576.25 -3.21123316e+00 1.02453947e+01 1.07368585e+01 1.87452993 0.20780939 576.50 8.71953795e-01 -3.56911961e+00 3.67408740e+00 -1.33118480 0.02225899 576.75 -3.31405136e+00 -8.71418460e+00 9.32308692e+00 -1.93421016 0.18995016 577.00 -4.07328981e+00 -9.71567922e+00 1.05349947e+01 -1.96778585 0.57179320 577.25 -3.61035695e+00 -7.91342636e+00 8.69810290e+00 -1.99882054 0.62965455 577.50 -2.93490341e+00 -5.30122485e+00 6.05942596e+00 -2.07642024 0.73898751 577.75 -2.40567791e+00 -5.00310621e+00 5.55142846e+00 -2.01899624 0.79095064 578.00 -1.55750502e+00 -4.81609734e+00 5.06168109e+00 -1.88357648 0.81051616 578.25 -1.50088858e+00 -4.92290834e+00 5.14661957e+00 -1.86672272 0.82882224 578.50 -2.13267513e+00 -5.21909681e+00 5.63802046e+00 -1.95871943 0.87269201 578.75 -2.36805482e+00 -4.99199710e+00 5.52518947e+00 -2.01373070 0.87996079 579.00 -2.17027548e+00 -4.20964040e+00 4.73615540e+00 -2.04680554 0.83466207 579.25 -1.84603961e+00 -3.94118358e+00 4.35210182e+00 -2.00884366 0.82010539 579.50 -1.55138849e+00 -4.22350152e+00 4.49941900e+00 -1.92281939 0.85356708 579.75 -1.38691583e+00 -4.50541660e+00 4.71405497e+00 -1.86942376 0.84136010 580.00 -1.25707096e+00 -4.91202109e+00 5.07032332e+00 -1.82133637 0.85446836 580.25 -1.48802538e+00 -5.64542078e+00 5.83823563e+00 -1.82851566 0.84006729 580.50 -1.80745521e+00 -6.35604087e+00 6.60803677e+00 -1.84785095 0.90748039 580.75 -2.02852043e+00 -6.90604434e+00 7.19780130e+00 -1.85649202 0.88333994 581.00 -2.78008799e+00 -8.47781495e+00 8.92200849e+00 -1.88767157 0.89532553 581.25 -3.78478263e+00 -8.94431966e+00 9.71212818e+00 -1.97109837 0.85635619 581.50 -6.01260137e+00 -1.00956638e+01 1.17504810e+01 -2.10794676 0.84673791 581.75 -8.53980118e+00 -1.02265997e+01 1.33233459e+01 -2.26655142 0.79869625 582.00 -1.30863395e+01 -8.12198213e+00 1.54019114e+01 -2.58613055 0.82915307 582.25 -1.51185422e+01 -4.08475503e+00 1.56606367e+01 -2.87771137 0.84392291 582.50 -1.51290668e+01 -2.19596653e-01 1.51306604e+01 -3.12707879 0.92177570 582.75 -1.39108236e+01 1.86570130e+00 1.40353786e+01 3.00826957 0.93568239 583.00 -1.28836091e+01 2.75997112e+00 1.31759183e+01 2.93055886 0.95132816 583.25 -1.19216494e+01 3.10029970e+00 1.23181810e+01 2.88717189 0.94476880 583.50 -1.13848860e+01 3.92775582e+00 1.20433755e+01 2.80938144 0.95256697 583.75 -1.11293922e+01 4.18739133e+00 1.18910730e+01 2.78172989 0.94184126 584.00 -1.10790705e+01 4.74401743e+00 1.20520332e+01 2.73701780 0.94489657 584.25 -1.06352117e+01 5.89408170e+00 1.21592733e+01 2.63552719 0.93518549 584.50 -1.06889427e+01 6.14053960e+00 1.23271944e+01 2.62015236 0.94153608 584.75 -1.01405715e+01 8.44155488e+00 1.31943564e+01 2.44737381 0.90653322 585.00 -9.77301589e+00 1.04580967e+01 1.43137565e+01 2.32234469 0.91139188 585.25 -7.54983725e+00 1.12834329e+01 1.35762992e+01 2.16048730 0.90218400 585.50 -5.80981823e+00 1.17835620e+01 1.31379725e+01 2.02886392 0.90247491 585.75 -3.04440029e+00 1.17562207e+01 1.21440149e+01 1.82419074 0.80463645 586.00 -7.20533875e-01 1.20441461e+01 1.20656796e+01 1.63054951 0.81161904 586.25 2.51662555e+00 1.21877059e+01 1.24448214e+01 1.36716933 0.79946084 586.50 5.46715469e+00 1.08194896e+01 1.21223404e+01 1.10291281 0.78208677 586.75 8.25029946e+00 4.46995317e+00 9.38338545e+00 0.49652030 0.57928093 587.00 7.95556565e+00 8.91709493e-01 8.00538385e+00 0.11162036 0.54486830 587.25 4.64971826e+00 -4.54690747e+00 6.50340276e+00 -0.77421944 0.44922567 587.50 1.85994120e+00 -5.36088060e+00 5.67436534e+00 -1.23684395 0.43190969 587.75 -3.18493903e+00 -4.09975481e+00 5.19151482e+00 -2.23126793 0.53368232 588.00 -4.94829585e+00 -2.97480298e+00 5.77365435e+00 -2.60030797 0.65203104 588.25 -5.60506001e+00 -6.12974627e-02 5.60539518e+00 -3.13065700 0.78862706 588.50 -5.41550015e+00 7.56001034e-01 5.46801422e+00 3.00288955 0.85990592 588.75 -4.50885846e+00 1.37917923e+00 4.71507582e+00 2.84474818 0.88172162 589.00 -4.41760012e+00 1.44519905e+00 4.64798786e+00 2.82542123 0.88828041 589.25 -4.33205055e+00 1.48413677e+00 4.57922744e+00 2.81153032 0.89104729 589.50 -4.46636160e+00 1.52349236e+00 4.71904810e+00 2.81286517 0.91356724 589.75 -4.76344306e+00 1.30499072e+00 4.93896655e+00 2.87419400 0.91191508 590.00 -5.23701222e+00 1.53949925e+00 5.45860376e+00 2.85568154 0.90850240 590.25 -5.79507192e+00 2.44043696e+00 6.28797194e+00 2.74301060 0.93783790 590.50 -5.92037707e+00 2.84877544e+00 6.57011310e+00 2.69311293 0.92726677 590.75 -5.37214654e+00 3.50502458e+00 6.41444899e+00 2.56350128 0.92820151 591.00 -5.08743879e+00 3.80016373e+00 6.35006124e+00 2.50003362 0.91798344 591.25 -4.14893993e+00 4.41728905e+00 6.06020999e+00 2.32487833 0.90682153 591.50 -3.52114327e+00 4.41314058e+00 5.64572934e+00 2.24424140 0.89237737 591.75 -3.21701163e+00 4.12978744e+00 5.23491243e+00 2.23258660 0.90108839 592.00 -3.37156780e+00 3.78695736e+00 5.07035654e+00 2.29823223 0.86900623 592.25 -4.00320214e+00 3.48766609e+00 5.30937305e+00 2.42490808 0.86095564 592.50 -4.31891017e+00 4.30505954e+00 6.09807533e+00 2.35780055 0.87716630 592.75 -4.75377020e+00 5.19352804e+00 7.04067217e+00 2.31201448 0.92789704 593.00 -4.15089582e+00 5.97485060e+00 7.27521654e+00 2.17797525 0.85245029 593.25 -2.74601015e+00 6.96097616e+00 7.48303153e+00 1.94654055 0.89950299 593.50 -1.12615662e+00 6.83513811e+00 6.92728964e+00 1.73408919 0.84686857 593.75 2.33519385e-01 5.92822011e+00 5.93281763e+00 1.53142554 0.83032868 594.00 1.72247248e+00 4.40097630e+00 4.72604526e+00 1.19773938 0.66994951 594.25 1.84678699e+00 2.26209969e+00 2.92022554e+00 0.88613274 0.46226162 594.50 6.02787996e-01 5.28604234e-01 8.01733001e-01 0.71992332 0.07367456 594.75 -8.10331996e-01 3.76314478e-01 8.93448672e-01 2.70683218 0.14490491 595.00 -2.15430284e+00 1.22660007e+00 2.47902571e+00 2.62399813 0.54650589 595.25 -2.49876242e+00 1.67227215e+00 3.00671046e+00 2.55181052 0.63308196 595.50 -1.85059232e+00 2.68645868e+00 3.26216986e+00 2.17400618 0.61823737 595.75 -1.19175332e+00 3.44875722e+00 3.64886316e+00 1.90351043 0.73992027 596.00 -8.07363034e-01 4.10814731e+00 4.18673015e+00 1.76485052 0.76269483 596.25 -4.52741803e-01 4.65781553e+00 4.67976716e+00 1.66769239 0.81584302 596.50 4.82600610e-01 5.00744874e+00 5.03065068e+00 1.47471653 0.76918498 596.75 1.59111761e+00 5.21798572e+00 5.45518379e+00 1.27482324 0.78157313 597.00 3.11239279e+00 5.35003088e+00 6.18949265e+00 1.04390232 0.79409897 597.25 3.91225689e+00 5.68595100e+00 6.90186879e+00 0.96813103 0.80840560 597.50 6.50233861e+00 6.02258358e+00 8.86295212e+00 0.74711285 0.73137849 597.75 9.09237688e+00 5.79778562e+00 1.07835818e+01 0.56764674 0.73089360 598.00 1.31326811e+01 3.75444724e+00 1.36588135e+01 0.27845824 0.73000125 598.25 1.53693003e+01 2.81832987e+00 1.56255680e+01 0.18135911 0.73066208 598.50 2.05107095e+01 -2.63082106e+00 2.06787433e+01 -0.12756918 0.74895096 598.75 2.34534310e+01 -5.85821869e+00 2.41739975e+01 -0.24477242 0.79519670 599.00 2.48896758e+01 -1.30871951e+01 2.81206443e+01 -0.48408035 0.82730433 599.25 2.49299665e+01 -1.71047829e+01 3.02337035e+01 -0.60134514 0.83502341 599.50 2.35115915e+01 -2.33919266e+01 3.31659036e+01 -0.78284687 0.84966397 599.75 2.29520841e+01 -2.68184845e+01 3.52991399e+01 -0.86292693 0.87607570 600.00 1.94092727e+01 -3.37660018e+01 3.89469221e+01 -1.04909957 0.89686313 600.25 1.72317512e+01 -3.86571984e+01 4.23238968e+01 -1.15147574 0.89737463 600.50 1.69905487e+01 -4.75357012e+01 5.04809036e+01 -1.22752030 0.89049970 600.75 1.49339909e+01 -5.07302271e+01 5.28827006e+01 -1.28450295 0.88285267 601.00 6.75089997e+00 -5.80896667e+01 5.84806295e+01 -1.45510017 0.89237163 601.25 -1.71299612e+00 -6.05345951e+01 6.05588272e+01 -1.59908658 0.88390263 601.50 -7.50215106e+00 -5.93144099e+01 5.97869676e+01 -1.69660936 0.90078747 601.75 -1.12094571e+01 -6.13749457e+01 6.23901906e+01 -1.75144424 0.90569144 602.00 -2.03355399e+01 -6.70908915e+01 7.01050776e+01 -1.86509869 0.91484955 602.25 -2.96656475e+01 -6.63750115e+01 7.27027702e+01 -1.99110264 0.91868416 602.50 -3.97883813e+01 -6.13970785e+01 7.31622616e+01 -2.14579955 0.94458275 602.75 -4.42473015e+01 -5.88779356e+01 7.36507636e+01 -2.21526253 0.95323383 603.00 -4.69361748e+01 -5.43408604e+01 7.18048300e+01 -2.28321118 0.96743117 603.25 -4.64025769e+01 -4.96675598e+01 6.79710647e+01 -2.32222216 0.96151433 603.50 -4.44316897e+01 -4.76278152e+01 6.51351198e+01 -2.32149039 0.95312434 603.75 -4.24612374e+01 -4.46705693e+01 6.16312944e+01 -2.33084372 0.96179216 604.00 -4.18315155e+01 -4.38346743e+01 6.05917021e+01 -2.33281544 0.97668237 604.25 -4.04924305e+01 -4.39752478e+01 5.97784187e+01 -2.31498529 0.97585981 604.50 -4.11837535e+01 -4.45481155e+01 6.06682466e+01 -2.31697178 0.97887879 604.75 -3.95416162e+01 -4.49725430e+01 5.98837961e+01 -2.29202217 0.97657697 605.00 -3.88116471e+01 -4.66466997e+01 6.06816162e+01 -2.26476738 0.98204289 605.25 -3.80544384e+01 -4.79967281e+01 6.12521525e+01 -2.24116526 0.97797214 605.50 -3.60081744e+01 -4.87307349e+01 6.05910319e+01 -2.20716923 0.97391274 605.75 -3.42990953e+01 -5.17562645e+01 6.20897645e+01 -2.15605068 0.97269991 606.00 -3.29020499e+01 -5.32530198e+01 6.25973562e+01 -2.12423308 0.97483322 606.25 -3.15167959e+01 -5.85957897e+01 6.65340138e+01 -2.06427740 0.96253002 606.50 -3.13553714e+01 -6.24000626e+01 6.98349993e+01 -2.03643349 0.96484043 606.75 -3.53440193e+01 -6.86005437e+01 7.71701645e+01 -2.04654160 0.94404193 607.00 -3.92879290e+01 -7.29275119e+01 8.28369686e+01 -2.06494250 0.93406266 607.25 -5.40414529e+01 -7.90393436e+01 9.57480886e+01 -2.17051815 0.94724558 607.50 -5.95047628e+01 -8.08753639e+01 1.00407377e+02 -2.20512061 0.95641323 607.75 -7.15180761e+01 -7.86172610e+01 1.06280332e+02 -2.30894445 0.93231380 608.00 -8.04438919e+01 -7.55407784e+01 1.10352295e+02 -2.38761745 0.94631878 608.25 -9.25467529e+01 -5.88423857e+01 1.09669174e+02 -2.57525579 0.92329993 608.50 -1.00770029e+02 -4.69439007e+01 1.11168019e+02 -2.70563483 0.91077959 608.75 -9.33437935e+01 -2.69431986e+01 9.71545148e+01 -2.86058577 0.92691938 609.00 -8.72254538e+01 -1.91344687e+01 8.92995391e+01 -2.92564530 0.92510495 609.25 -6.64301719e+01 -1.34868968e+01 6.77854271e+01 -2.94129142 0.91130426 609.50 -6.11952561e+01 -1.39221784e+01 6.27589548e+01 -2.91789595 0.92622663 609.75 -5.50463819e+01 -2.02531449e+01 5.86540198e+01 -2.78903583 0.92901523 610.00 -5.05421288e+01 -2.65651157e+01 5.70982675e+01 -2.65767273 0.92345842 610.25 -5.07210079e+01 -3.75065667e+01 6.30821940e+01 -2.50486611 0.93318021 610.50 -5.15732456e+01 -4.21130041e+01 6.65830667e+01 -2.45683127 0.92600520 610.75 -5.59937082e+01 -4.67954446e+01 7.29733444e+01 -2.44544348 0.88514287 611.00 -6.16534492e+01 -4.66794666e+01 7.73312383e+01 -2.49354610 0.84917371 611.25 -8.06673717e+01 -4.45039176e+01 9.21293848e+01 -2.63744778 0.89048195 611.50 -8.85446914e+01 -3.50385134e+01 9.52253107e+01 -2.76478520 0.83891683 611.75 -9.85110126e+01 -6.72387014e+00 9.87402149e+01 -3.07344334 0.80511400 612.00 -8.75235415e+01 7.70247000e+00 8.78618140e+01 3.05381424 0.79096967 612.25 -8.52200398e+01 1.97301918e+01 8.74741999e+01 2.91408058 0.87991072 612.50 -7.54023670e+01 2.34233822e+01 7.89567716e+01 2.84039847 0.88031278 612.75 -6.61282914e+01 2.74196792e+01 7.15876367e+01 2.74852649 0.91551086 613.00 -6.03950901e+01 2.46226550e+01 6.52214846e+01 2.75447203 0.91020947 613.25 -5.58970280e+01 2.10180660e+01 5.97179775e+01 2.78193328 0.94510586 613.50 -5.56832869e+01 2.07519040e+01 5.94244895e+01 2.78485977 0.94418093 613.75 -5.56693712e+01 2.09030365e+01 5.94644081e+01 2.78239649 0.94940057 614.00 -5.21422766e+01 2.25654315e+01 5.68156291e+01 2.73316213 0.93694444 614.25 -5.07663884e+01 2.45275190e+01 5.63810729e+01 2.69151986 0.95090300 614.50 -4.80280203e+01 2.79711441e+01 5.55794534e+01 2.61422069 0.95959354 614.75 -4.72265579e+01 2.83572957e+01 5.50861506e+01 2.60084064 0.97200990 615.00 -4.58315366e+01 2.77079353e+01 5.35561334e+01 2.59782661 0.96472480 615.25 -4.51937785e+01 2.89645390e+01 5.36788798e+01 2.57164366 0.96704636 615.50 -4.19380582e+01 3.20176406e+01 5.27629608e+01 2.48953852 0.96840061 615.75 -4.06528098e+01 3.45229947e+01 5.33337427e+01 2.43755423 0.97645031 616.00 -3.79682325e+01 3.71322718e+01 5.31073657e+01 2.36732526 0.97038320 616.25 -3.46598236e+01 3.87190940e+01 5.19660621e+01 2.30093152 0.96989877 616.50 -2.71403553e+01 3.92503881e+01 4.77199314e+01 2.17577258 0.94798693 616.75 -2.24882102e+01 3.71750087e+01 4.34476797e+01 2.11483161 0.95019112 617.00 -1.86277890e+01 3.53919971e+01 3.99948494e+01 2.05528360 0.94275303 617.25 -1.80691469e+01 3.41271899e+01 3.86155300e+01 2.05773701 0.95556369 617.50 -1.94896684e+01 3.28594861e+01 3.82046202e+01 2.10614277 0.95150223 617.75 -1.99762014e+01 3.35997202e+01 3.90895104e+01 2.10718757 0.94703400 618.00 -1.48090145e+01 3.79111679e+01 4.07009037e+01 1.94319396 0.92241059 618.25 -1.12694401e+01 4.03381405e+01 4.18827633e+01 1.84322473 0.91994986 618.50 -5.55673709e+00 4.13874835e+01 4.17588448e+01 1.70425950 0.90861401 618.75 6.03917096e-02 4.06575568e+01 4.06576016e+01 1.56931095 0.92047977 619.00 6.79993751e+00 3.68838816e+01 3.75054646e+01 1.38848279 0.87464112 619.25 9.47314037e+00 3.18564387e+01 3.32351181e+01 1.28175437 0.86445776 619.50 1.27201459e+01 2.29555850e+01 2.62442564e+01 1.06479557 0.88251041 619.75 1.25972888e+01 2.05214891e+01 2.40795183e+01 1.02024908 0.89567686 620.00 1.04939491e+01 1.80933024e+01 2.09162750e+01 1.04521941 0.87242649 620.25 1.00423966e+01 1.62208287e+01 1.90778671e+01 1.01644733 0.85024369 620.50 1.13072732e+01 1.42468312e+01 1.81886400e+01 0.89992748 0.82993033 620.75 1.16668228e+01 1.25976622e+01 1.71702023e+01 0.82374158 0.82633307 621.00 1.15318794e+01 1.08137083e+01 1.58088750e+01 0.75326994 0.82117025 621.25 9.58787054e+00 9.33528058e+00 1.33818805e+01 0.77205076 0.78675356 621.50 7.00355874e+00 8.82631938e+00 1.12673754e+01 0.90004012 0.79378100 621.75 5.82756320e+00 9.72481885e+00 1.13372216e+01 1.03093109 0.71673149 622.00 7.15289697e+00 1.28266897e+01 1.46863168e+01 1.06209321 0.70141550 622.25 8.39670860e+00 1.36920196e+01 1.60616349e+01 1.02068699 0.71544612 622.50 1.22737142e+01 1.44463946e+01 1.89563281e+01 0.86653222 0.73081785 622.75 1.63037130e+01 1.26946910e+01 2.06631614e+01 0.66157895 0.74976471 623.00 1.99680843e+01 1.09546084e+01 2.27755974e+01 0.50177224 0.83978234 623.25 2.14677574e+01 9.56511115e+00 2.35022543e+01 0.41915305 0.85791060 623.50 2.32567758e+01 7.81723956e+00 2.45354204e+01 0.32426310 0.88958527 623.75 2.45230800e+01 7.21700147e+00 2.55629921e+01 0.28621398 0.88078784 624.00 2.76976996e+01 5.38670813e+00 2.82166473e+01 0.19208435 0.88554778 624.25 3.10436201e+01 3.63276837e+00 3.12554532e+01 0.11649160 0.87483790 624.50 3.32797782e+01 -1.96010864e-01 3.32803554e+01 -0.00588972 0.89153160 624.75 3.89432362e+01 -4.61991644e+00 3.92163139e+01 -0.11808019 0.85557109 625.00 4.62249700e+01 -1.05489188e+01 4.74133688e+01 -0.22436598 0.87118655 625.25 5.18372789e+01 -2.06028642e+01 5.57815516e+01 -0.37830846 0.83794716 625.50 5.73284990e+01 -3.17356897e+01 6.55264129e+01 -0.50558467 0.85085350 625.75 5.72396541e+01 -5.00875612e+01 7.60601195e+01 -0.71885834 0.73716035 626.00 5.63391599e+01 -7.96939660e+01 9.75972805e+01 -0.95542524 0.74217757 626.25 1.90784415e+01 -8.96671557e+01 9.16743462e+01 -1.36115303 0.58364411 626.50 -2.83276651e+01 -1.01871133e+02 1.05736391e+02 -1.84201772 0.57605370 626.75 -7.63381394e+01 -7.99686681e+01 1.10555413e+02 -2.33297173 0.53522780 627.00 -9.73636857e+01 -4.50541068e+01 1.07282617e+02 -2.70819450 0.53339298 627.25 -9.44815105e+01 -1.86296219e-01 9.44816941e+01 -3.13962088 0.61846747 627.50 -9.66499472e+01 1.82719967e+01 9.83619752e+01 2.95474453 0.74190033 627.75 -6.68901150e+01 4.14395443e+01 7.86862333e+01 2.58694610 0.74045159 628.00 -5.21468395e+01 4.71599718e+01 7.03090024e+01 2.40636912 0.79047860 628.25 -3.03980636e+01 5.05348871e+01 5.89730200e+01 2.11233735 0.79247200 628.50 -2.10887247e+01 4.35607376e+01 4.83970264e+01 2.02166129 0.79576986 628.75 -1.38215704e+01 3.60125264e+01 3.85737977e+01 1.93725876 0.81180485 629.00 -1.17975606e+01 3.34815813e+01 3.54992777e+01 1.90957180 0.79315918 629.25 -5.81653952e+00 2.62244018e+01 2.68617085e+01 1.78906169 0.72372544 629.50 -4.91194911e+00 2.09509607e+01 2.15190612e+01 1.80108684 0.69140252 629.75 -7.26114042e+00 1.56848162e+01 1.72840278e+01 2.00435951 0.70928858 630.00 -8.71849986e+00 1.43792381e+01 1.68159070e+01 2.11585401 0.70561421 630.25 -9.64193331e+00 1.35125147e+01 1.65998473e+01 2.19056233 0.72591463 630.50 -9.93446772e+00 1.42239800e+01 1.73497913e+01 2.18046845 0.75230957 630.75 -9.06695333e+00 1.42166158e+01 1.68618447e+01 2.13852702 0.77973246 631.00 -7.94597364e+00 1.49298818e+01 1.69127132e+01 2.05988605 0.80930473 631.25 -6.31569024e+00 1.59598088e+01 1.71640158e+01 1.94761166 0.79324728 631.50 -5.60072380e+00 1.40553501e+01 1.51301346e+01 1.94998847 0.75677817 631.75 -4.67269362e+00 1.26431642e+01 1.34790084e+01 1.92480907 0.76885881 632.00 -5.75569774e+00 1.11851131e+01 1.25791420e+01 2.04604418 0.77751981 632.25 -7.52526422e+00 1.00254960e+01 1.25355563e+01 2.21468942 0.85573992 632.50 -8.40470576e+00 1.00798210e+01 1.31240951e+01 2.26581879 0.87939490 632.75 -9.94990233e+00 1.04002167e+01 1.43932298e+01 2.33406976 0.93101454 633.00 -1.07049167e+01 1.16364404e+01 1.58114511e+01 2.31452359 0.93759305 633.25 -1.16968528e+01 1.31752057e+01 1.76182409e+01 2.29682604 0.95868815 633.50 -1.13512745e+01 1.41998391e+01 1.81792977e+01 2.24516801 0.94211735 633.75 -1.10563150e+01 1.71689031e+01 2.04209043e+01 2.14292317 0.95667877 634.00 -1.01556326e+01 1.88656949e+01 2.14254829e+01 2.06462187 0.95378514 634.25 -7.95720518e+00 2.18911861e+01 2.32925126e+01 1.91943716 0.96267990 634.50 -4.81462373e+00 2.37097592e+01 2.41936621e+01 1.77113732 0.95731577 634.75 -1.30207409e+00 2.35158501e+01 2.35518705e+01 1.62610991 0.97327660 635.00 1.54646642e+00 2.27296938e+01 2.27822417e+01 1.50286374 0.96384021 635.25 4.66063213e+00 2.20389312e+01 2.25263397e+01 1.36239406 0.97612118 635.50 6.53111245e+00 1.95079781e+01 2.05722298e+01 1.24773367 0.95586172 635.75 8.44348717e+00 1.66855690e+01 1.87002858e+01 1.10233213 0.96490583 636.00 7.83633258e+00 1.51020953e+01 1.70141527e+01 1.09215084 0.96798205 636.25 7.72223474e+00 1.37913316e+01 1.58061297e+01 1.06035829 0.97820851 636.50 7.19143930e+00 1.29107599e+01 1.47785155e+01 1.06258609 0.97401382 636.75 6.97222487e+00 1.23816603e+01 1.42097653e+01 1.05794433 0.97979568 637.00 7.52711258e+00 1.22042050e+01 1.43387602e+01 1.01814157 0.98097357 637.25 7.77201853e+00 1.19036137e+01 1.42161982e+01 0.99237636 0.98354004 637.50 8.16501263e+00 1.10692374e+01 1.37548337e+01 0.93525849 0.98601862 637.75 8.32039965e+00 1.06470378e+01 1.35125299e+01 0.90745329 0.98815665 638.00 8.96154246e+00 9.78402626e+00 1.32678715e+01 0.82924621 0.97709476 638.25 9.10053412e+00 9.13351069e+00 1.28934378e+01 0.78720668 0.98308160 638.50 9.34779432e+00 8.72667827e+00 1.27881262e+01 0.75104741 0.98474115 638.75 9.48692813e+00 8.45429036e+00 1.27073534e+01 0.72790487 0.98618631 639.00 9.65116389e+00 7.87003624e+00 1.24532098e+01 0.68409060 0.97778796 639.25 9.92466176e+00 7.11763280e+00 1.22130917e+01 0.62215429 0.97335620 639.50 1.00901514e+01 5.91783913e+00 1.16975201e+01 0.53043133 0.96588973 639.75 1.00161549e+01 5.37560489e+00 1.13675189e+01 0.49256970 0.96186547 640.00 1.01968608e+01 4.82938597e+00 1.12826832e+01 0.44231767 0.97164150 640.25 9.95546308e+00 4.36099993e+00 1.08687426e+01 0.41287277 0.96751899 640.50 9.95489050e+00 2.63008486e+00 1.02964650e+01 0.25829834 0.95570063 640.75 9.72660063e+00 1.94767598e+00 9.91968757e+00 0.19762844 0.94756592 641.00 8.86054350e+00 7.77191564e-01 8.89456338e+00 0.08748984 0.94259457 641.25 8.33241499e+00 2.41562940e-01 8.33591580e+00 0.02898263 0.93657138 641.50 7.14243980e+00 -2.96106008e-01 7.14857504e+00 -0.04143354 0.88759797 641.75 6.44548918e+00 -4.64912993e-01 6.46223451e+00 -0.07200528 0.82454034 642.00 4.25751722e+00 -1.09325722e+00 4.39564151e+00 -0.25135222 0.71358364 642.25 3.43037984e+00 -7.21053385e-01 3.50534218e+00 -0.20718026 0.65597498 642.50 2.54275846e+00 6.83231836e-01 2.63295012e+00 0.26249707 0.53131528 642.75 1.88536099e+00 1.50786414e+00 2.41417488e+00 0.67460359 0.46201774 643.00 1.15920736e+00 2.68684436e+00 2.92624235e+00 1.16348511 0.59344902 643.25 1.30512043e+00 3.26456272e+00 3.51578002e+00 1.19047604 0.61607900 643.50 1.19251195e+00 4.27471596e+00 4.43793661e+00 1.29874420 0.74163991 643.75 1.28936915e+00 4.76118907e+00 4.93268630e+00 1.30633134 0.76972131 644.00 1.02563418e+00 5.90106954e+00 5.98953647e+00 1.39871059 0.85980734 644.25 1.39644278e+00 6.82106289e+00 6.96253915e+00 1.36886156 0.84402491 644.50 2.26388409e+00 9.05827947e+00 9.33689446e+00 1.32588892 0.92293604 644.75 3.21566203e+00 9.73075656e+00 1.02483221e+01 1.25163064 0.92575800 645.00 4.03251836e+00 1.01463443e+01 1.09183106e+01 1.19250260 0.93908005 645.25 4.80525473e+00 1.08730756e+01 1.18875669e+01 1.15466469 0.94752651 645.50 5.84435052e+00 1.14092508e+01 1.28190264e+01 1.09739947 0.95629480 645.75 7.60409349e+00 1.22398778e+01 1.44096095e+01 1.01489410 0.94289994 646.00 9.22043556e+00 1.28627135e+01 1.58261123e+01 0.94886123 0.96798168 646.25 1.14141042e+01 1.36550396e+01 1.77972437e+01 0.87455139 0.95854971 646.50 1.38181925e+01 1.32770995e+01 1.91630847e+01 0.76543082 0.97086503 646.75 1.66691976e+01 1.22468021e+01 2.06844462e+01 0.63363475 0.97236235 647.00 1.86658555e+01 1.11432901e+01 2.17390680e+01 0.53820179 0.98093988 647.25 2.05877427e+01 8.86047837e+00 2.24134608e+01 0.40641567 0.97017320 647.50 2.18096173e+01 6.56911911e+00 2.27774611e+01 0.29255997 0.98440681 647.75 2.19805040e+01 4.21522420e+00 2.23810337e+01 0.18947073 0.97775402 648.00 2.26829613e+01 2.58855327e+00 2.28301849e+01 0.11362728 0.98058483 648.25 2.28846659e+01 1.77054283e-01 2.28853508e+01 0.00773665 0.96905922 648.50 2.27381847e+01 -1.04527083e+00 2.27621975e+01 -0.04593750 0.97573608 648.75 2.32430867e+01 -2.20804086e+00 2.33477306e+01 -0.09471351 0.97125112 649.00 2.35507628e+01 -2.27481451e+00 2.36603722e+01 -0.09629324 0.97683151 649.25 2.45160677e+01 -4.63098790e+00 2.49496217e+01 -0.18669623 0.97054037 649.50 2.56185192e+01 -5.45143718e+00 2.61921112e+01 -0.20966555 0.96524030 649.75 2.88853764e+01 -7.74878747e+00 2.99066661e+01 -0.26208924 0.95825206 650.00 3.07174697e+01 -1.09918747e+01 3.26249023e+01 -0.34364022 0.95380274 650.25 3.40624053e+01 -1.77803747e+01 3.84238100e+01 -0.48108768 0.95287502 650.50 3.37067639e+01 -2.19297192e+01 4.02126661e+01 -0.57679895 0.94651166 650.75 2.63223281e+01 -3.11134395e+01 4.07542768e+01 -0.86862235 0.92283789 651.00 2.31909071e+01 -3.57675153e+01 4.26278468e+01 -0.99556147 0.93895596 651.25 1.82630862e+01 -4.13642560e+01 4.52166119e+01 -1.15501792 0.90263873 651.50 1.26802319e+01 -4.59896715e+01 4.77057457e+01 -1.30176168 0.84978935 651.75 -1.00038660e+01 -4.81283647e+01 4.91570628e+01 -1.77573612 0.83699355 652.00 -1.88988831e+01 -3.94757211e+01 4.37664294e+01 -2.01729744 0.81689865 652.25 -2.15589241e+01 -2.30141449e+01 3.15347122e+01 -2.32355810 0.85897135 652.50 -2.15804183e+01 -1.99950004e+01 2.94196277e+01 -2.39430956 0.86863055 652.75 -1.94946759e+01 -1.29623210e+01 2.34107701e+01 -2.55480306 0.91094053 653.00 -1.80405793e+01 -1.17856035e+01 2.15490823e+01 -2.56291300 0.92132397 653.25 -1.62595945e+01 -9.40764956e+00 1.87850548e+01 -2.61706408 0.93675277 653.50 -1.47764310e+01 -7.80338426e+00 1.67103477e+01 -2.65572116 0.91425034 653.75 -1.23886008e+01 -4.52968867e+00 1.31907357e+01 -2.79105880 0.93609073 654.00 -1.10923792e+01 -3.35865004e+00 1.15897112e+01 -2.84757914 0.91792168 654.25 -8.86146440e+00 -1.90365937e+00 9.06363450e+00 -2.92998428 0.86865422 654.50 -7.19348934e+00 -2.17483946e+00 7.51506591e+00 -2.84799556 0.82217865 654.75 -6.12303966e+00 -3.29382662e+00 6.95276265e+00 -2.64805585 0.87627863 655.00 -5.48530506e+00 -3.45900428e+00 6.48485020e+00 -2.57898030 0.81096874 655.25 -5.05529179e+00 -4.09312225e+00 6.50458491e+00 -2.46098262 0.82908777 655.50 -5.12836762e+00 -4.46379414e+00 6.79894202e+00 -2.42536692 0.80843784 655.75 -5.79009290e+00 -4.98339758e+00 7.63933421e+00 -2.43093283 0.88478382 656.00 -6.09106759e+00 -4.06976777e+00 7.32557944e+00 -2.55256145 0.86425195 656.25 -6.07720152e+00 -3.29018824e+00 6.91069584e+00 -2.64537720 0.87108286 656.50 -5.05405863e+00 -3.08938593e+00 5.92349678e+00 -2.59292880 0.77036926 656.75 -3.67539922e+00 -3.03372544e+00 4.76571605e+00 -2.45154641 0.74937910 657.00 -2.99854155e+00 -4.20834343e+00 5.16734031e+00 -2.18987765 0.75994343 657.25 -2.99475305e+00 -5.14428614e+00 5.95249744e+00 -2.09798842 0.85188800 657.50 -3.79432348e+00 -5.80154745e+00 6.93216009e+00 -2.14999182 0.83635899 657.75 -5.57920016e+00 -6.38495099e+00 8.47909627e+00 -2.28894894 0.86751627 658.00 -7.09445306e+00 -5.26826119e+00 8.83661928e+00 -2.50285163 0.87332813 658.25 -7.68327132e+00 -3.65973285e+00 8.51036443e+00 -2.69706394 0.88786804 658.50 -7.80449755e+00 -2.94574619e+00 8.34191840e+00 -2.78068266 0.92032751 658.75 -7.87113380e+00 -2.60040370e+00 8.28956252e+00 -2.82250949 0.91765225 659.00 -7.67068199e+00 -1.33373393e+00 7.78576961e+00 -2.96943951 0.85230941 659.25 -7.27451401e+00 -4.60440316e-01 7.28907123e+00 -3.07838198 0.81600586 659.50 -6.32761142e+00 9.86741886e-01 6.40408665e+00 2.98689635 0.74751790 659.75 -5.40536825e+00 1.47673367e+00 5.60345860e+00 2.87490288 0.73410133 660.00 -4.02175065e+00 5.33938529e-03 4.02175419e+00 3.14026503 0.61704173 660.25 -4.44353009e+00 -5.48743845e-01 4.47728483e+00 -3.01872197 0.68029257 660.50 -6.49342373e+00 -2.00049139e+00 6.79459473e+00 -2.84273996 0.72691001 660.75 -7.32021872e+00 -1.86060526e+00 7.55297650e+00 -2.89268991 0.62676992 661.00 -6.82309031e+00 2.68832069e+00 7.33359595e+00 2.76626644 0.32475402 661.25 -5.80292907e+00 5.51583789e+00 8.00615098e+00 2.38155323 0.34153316 661.50 -6.59159136e+00 6.85476572e+00 9.50983121e+00 2.33662482 0.37048923 661.75 -4.81970104e+00 6.62807957e+00 8.19517888e+00 2.19952151 0.21596346 662.00 -5.37160828e+00 -1.26064094e+00 5.51755300e+00 -2.91107834 0.10835999 662.25 -5.83816265e+00 -6.37616545e+00 8.64520845e+00 -2.31217608 0.29355797 662.50 -6.93469747e+00 -8.81443230e+00 1.12153576e+01 -2.23740162 0.65483484 662.75 -5.62609176e+00 -6.96606591e+00 8.95427176e+00 -2.25018006 0.65226123 663.00 -4.02173896e+00 -6.19310785e+00 7.38437331e+00 -2.14674222 0.79110429 663.25 -3.54020580e+00 -6.30874964e+00 7.23418131e+00 -2.08216582 0.83922664 663.50 -3.67391670e+00 -5.93861577e+00 6.98318131e+00 -2.12481534 0.89004146 663.75 -4.06236055e+00 -5.64141946e+00 6.95186211e+00 -2.19488225 0.90331414 664.00 -4.20054219e+00 -4.98743620e+00 6.52066519e+00 -2.27075910 0.95294508 664.25 -4.20492936e+00 -4.74966992e+00 6.34356329e+00 -2.29543576 0.95397735 664.50 -4.29757740e+00 -4.24894973e+00 6.04340511e+00 -2.36188419 0.94963414 664.75 -4.41566287e+00 -4.05974827e+00 5.99830264e+00 -2.39816362 0.94956832 665.00 -4.60271050e+00 -4.00182538e+00 6.09914341e+00 -2.42591483 0.96831140 665.25 -4.45384959e+00 -3.76234494e+00 5.83026720e+00 -2.44016022 0.96263495 665.50 -4.35243912e+00 -3.50730782e+00 5.58971685e+00 -2.46330946 0.96593906 665.75 -4.50459130e+00 -3.29961044e+00 5.58379546e+00 -2.50938633 0.97011548 666.00 -4.59709486e+00 -3.14612136e+00 5.57057994e+00 -2.54143271 0.98161151 666.25 -4.68184804e+00 -3.06180077e+00 5.59413309e+00 -2.56242975 0.97601328 666.50 -4.85899718e+00 -2.95388206e+00 5.68641125e+00 -2.59536989 0.97665233 666.75 -5.05503696e+00 -2.71124094e+00 5.73622054e+00 -2.64929398 0.96823573 667.00 -5.08971848e+00 -2.36739967e+00 5.61336044e+00 -2.70622504 0.97191532 667.25 -5.01910571e+00 -2.09868495e+00 5.44021145e+00 -2.74554747 0.96238061 667.50 -4.88772787e+00 -1.76110696e+00 5.19532304e+00 -2.79576090 0.95836734 667.75 -4.64107310e+00 -1.51723186e+00 4.88278118e+00 -2.82563056 0.94590196 668.00 -4.44596143e+00 -1.40410585e+00 4.66241206e+00 -2.83568964 0.93575900 668.25 -3.93885195e+00 -1.95904940e+00 4.39913960e+00 -2.68005480 0.89279851 668.50 -3.74926836e+00 -2.45802970e+00 4.48318226e+00 -2.56128902 0.91930693 668.75 -4.43696443e+00 -3.46505554e+00 5.62967701e+00 -2.47857484 0.90532929 669.00 -5.17442316e+00 -3.90034749e+00 6.47976586e+00 -2.49568033 0.92596392 669.25 -6.86349182e+00 -3.87938359e+00 7.88397977e+00 -2.62713928 0.91459162 669.50 -7.82954669e+00 -3.75405331e+00 8.68301316e+00 -2.69450139 0.92659280 669.75 -9.02141619e+00 -1.58411314e+00 9.15944128e+00 -2.96776999 0.90286362 670.00 -9.48924767e+00 6.74717177e-02 9.48948754e+00 3.13448244 0.93203943 670.25 -8.78696976e+00 1.60907356e+00 8.93308207e+00 2.96047888 0.93629324 670.50 -8.27958672e+00 2.26282270e+00 8.58323498e+00 2.87480630 0.94833405 670.75 -6.84663493e+00 2.79007432e+00 7.39330268e+00 2.75462869 0.90129624 671.00 -5.98222932e+00 2.86415548e+00 6.63253001e+00 2.69506691 0.88299161 671.25 -5.84262177e+00 2.23191847e+00 6.25441358e+00 2.77669364 0.88129413 671.50 -5.79618420e+00 2.36039195e+00 6.25837050e+00 2.75486734 0.89075502 671.75 -5.93042603e+00 2.50632532e+00 6.43829321e+00 2.74173837 0.91648004 672.00 -5.84249969e+00 2.53055412e+00 6.36698569e+00 2.73285715 0.90941518 672.25 -5.65307553e+00 3.98582713e+00 6.91694158e+00 2.52747055 0.85337684 672.50 -4.89456223e+00 4.17140826e+00 6.43097086e+00 2.43579171 0.82707781 672.75 -3.14207789e+00 3.61321627e+00 4.78831758e+00 2.28656367 0.74921397 673.00 -2.71701248e+00 3.02384741e+00 4.06519495e+00 2.30279774 0.68128523 673.25 -2.63861983e+00 2.72983852e+00 3.79662125e+00 2.33920453 0.70580294 673.50 -2.90550382e+00 2.17310415e+00 3.62826875e+00 2.49941972 0.65564845 673.75 -3.86890370e+00 1.40020608e+00 4.11448574e+00 2.79434469 0.78487242 674.00 -4.30119728e+00 1.32028675e+00 4.49927274e+00 2.84376470 0.77279266 674.25 -4.83466530e+00 1.78669530e+00 5.15424763e+00 2.78760046 0.78702413 674.50 -4.80252610e+00 2.95515250e+00 5.63889912e+00 2.58997515 0.79435215 674.75 -5.26046481e+00 4.66842656e+00 7.03325647e+00 2.41575180 0.89388558 675.00 -4.71790823e+00 5.25200011e+00 7.05989825e+00 2.30267526 0.86370436 675.25 -3.06361535e+00 5.91861947e+00 6.66451765e+00 2.04844297 0.89992703 675.50 -2.58996101e+00 5.81484204e+00 6.36555465e+00 1.98982267 0.90756596 675.75 -1.67308279e+00 5.54736602e+00 5.79417603e+00 1.86371990 0.91499722 676.00 -1.20192881e+00 5.37620270e+00 5.50891898e+00 1.79074415 0.91757666 676.25 -9.09689250e-01 5.21085728e+00 5.28966616e+00 1.74363031 0.94044075 676.50 -8.61500115e-01 4.88134908e+00 4.95678841e+00 1.74548553 0.94284492 676.75 -8.44734052e-01 4.63631455e+00 4.71264132e+00 1.75101889 0.94251968 677.00 -8.28243257e-01 4.59291246e+00 4.66699387e+00 1.74920960 0.91290330 677.25 -8.48401061e-01 4.62732639e+00 4.70445894e+00 1.75212820 0.90223449 677.50 -9.11976300e-01 4.61638931e+00 4.70560847e+00 1.76583680 0.87138112 677.75 -9.25647394e-01 4.71910790e+00 4.80903343e+00 1.76448609 0.85351455 678.00 -2.68722528e-01 4.96043051e+00 4.96770396e+00 1.62491665 0.79916208 678.25 7.43720497e-01 5.30220078e+00 5.35410620e+00 1.43143914 0.83730312 678.50 9.00181301e-01 4.88266928e+00 4.96495576e+00 1.38848100 0.86154134 678.75 9.93500773e-01 4.44941904e+00 4.55898822e+00 1.35111222 0.87934720 679.00 1.27119613e+00 4.14301803e+00 4.33365181e+00 1.27308666 0.89144802 679.25 1.48875521e+00 3.87204044e+00 4.14838394e+00 1.20373299 0.88782650 679.50 1.41480650e+00 3.20390378e+00 3.50238160e+00 1.15495953 0.86506894 679.75 1.31842246e+00 2.97550894e+00 3.25451858e+00 1.15370241 0.86577053 680.00 1.09624115e+00 2.84733887e+00 3.05107904e+00 1.20328269 0.88058189 680.25 1.02011448e+00 2.86463663e+00 3.04085130e+00 1.22869219 0.89248159 680.50 9.70245028e-01 2.97634787e+00 3.13049869e+00 1.25567371 0.87617311 680.75 1.03138346e+00 2.86752257e+00 3.04736567e+00 1.22552624 0.86482894 681.00 1.14615724e+00 3.04029900e+00 3.24916827e+00 1.21028361 0.87773423 681.25 1.26794531e+00 3.10123960e+00 3.35042868e+00 1.18268303 0.86414578 681.50 1.33766716e+00 3.45437455e+00 3.70432949e+00 1.20133933 0.88059306 681.75 1.38293811e+00 3.81612437e+00 4.05898054e+00 1.22312360 0.90741320 682.00 2.11614195e+00 4.35311273e+00 4.84021149e+00 1.11831299 0.89985295 682.25 2.52486877e+00 4.16868540e+00 4.87369473e+00 1.02621444 0.84901527 682.50 4.21547794e+00 4.29193703e+00 6.01589376e+00 0.79438527 0.88156817 682.75 4.72304611e+00 4.13892746e+00 6.27995901e+00 0.71958044 0.88302118 683.00 5.09645456e+00 2.72827960e+00 5.78077492e+00 0.49150971 0.83343015 683.25 5.68305799e+00 2.29154598e+00 6.12766930e+00 0.38328269 0.87104428 683.50 6.55075736e+00 1.28842117e+00 6.67626027e+00 0.19420390 0.85757550 683.75 6.37168023e+00 -8.36650145e-02 6.37222950e+00 -0.01313001 0.81147323 684.00 4.91408505e+00 -1.55584028e+00 5.15450006e+00 -0.30662330 0.86033235 684.25 4.50299984e+00 -2.05387698e+00 4.94928461e+00 -0.42792590 0.87047245 684.50 3.75851009e+00 -2.27430949e+00 4.39304925e+00 -0.54416789 0.85095361 684.75 3.20505188e+00 -2.12383965e+00 3.84487353e+00 -0.58521928 0.88014076 685.00 2.64694353e+00 -2.19245497e+00 3.43702907e+00 -0.69175855 0.91162669 685.25 2.31333338e+00 -2.18341616e+00 3.18100887e+00 -0.75651484 0.90204554 685.50 1.97396153e+00 -2.07637777e+00 2.86493783e+00 -0.81067862 0.92417335 685.75 1.77716029e+00 -2.26275308e+00 2.87721222e+00 -0.90502308 0.90426999 686.00 1.46512167e+00 -2.53224167e+00 2.92554771e+00 -1.04627063 0.91105717 686.25 1.10363136e+00 -2.65849439e+00 2.87847088e+00 -1.17731187 0.91233072 686.50 7.91598528e-01 -2.78823006e+00 2.89842286e+00 -1.29416819 0.91845747 686.75 3.38187652e-01 -2.61277982e+00 2.63457573e+00 -1.44207603 0.86870943 687.00 -2.51580867e-01 -2.37918291e+00 2.39244734e+00 -1.67614738 0.85435944 687.25 -6.87457379e-01 -1.95792927e+00 2.07511076e+00 -1.90846368 0.78277503 687.50 -1.00665163e+00 -1.53749617e+00 1.83772740e+00 -2.15049258 0.81163872 687.75 -1.05240710e+00 -1.04205492e+00 1.48102639e+00 -2.36113709 0.75299604 688.00 -1.04950019e+00 -6.84200741e-01 1.25282932e+00 -2.56386181 0.75586331 688.25 -8.65414540e-01 -3.16086867e-01 9.21332314e-01 -2.79140311 0.52553131 688.50 -6.54149314e-01 3.56949162e-02 6.55122471e-01 3.08707979 0.41357869 688.75 -4.16504324e-01 1.21666030e-01 4.33910676e-01 2.85738791 0.31692014 689.00 -2.57290413e-01 1.89895934e-01 3.19779334e-01 2.50577661 0.22095010 689.25 4.07091978e-02 2.63567891e-01 2.66693217e-01 1.41755295 0.15466806 689.50 1.90601865e-01 2.38751217e-01 3.05501579e-01 0.89707551 0.21994863 689.75 3.68899634e-01 1.18568088e-01 3.87485912e-01 0.31098159 0.26858610 690.00 5.04195027e-01 3.85661736e-02 5.05667850e-01 0.07634193 0.40898892 690.25 6.04193413e-01 -5.35838390e-02 6.06564843e-01 -0.08845514 0.57928744 690.50 6.03384102e-01 -1.59869583e-01 6.24204019e-01 -0.25900360 0.69789579 690.75 4.71107976e-01 -4.18261328e-01 6.29988304e-01 -0.72604758 0.75422795 691.00 3.70953027e-01 -5.02679159e-01 6.24733931e-01 -0.93505072 0.77368580 691.25 2.45630940e-01 -4.87389345e-01 5.45786526e-01 -1.10397558 0.73764843 691.50 1.21428912e-01 -4.41948355e-01 4.58326662e-01 -1.30265498 0.74762221 691.75 -5.75238459e-02 -3.96153933e-01 4.00308545e-01 -1.71499430 0.66922670 692.00 -6.72960921e-02 -3.08725013e-01 3.15974521e-01 -1.78541973 0.56885882 692.25 -1.00178074e-01 -1.53208501e-01 1.83053247e-01 -2.14988562 0.31709905 692.50 -5.67978372e-02 -1.00729976e-01 1.15639623e-01 -2.08422006 0.16910292 692.75 3.59042329e-02 -8.48816865e-02 9.21629787e-02 -1.17062812 0.11075074 693.00 1.10969451e-01 -6.93714698e-02 1.30868712e-01 -0.55870016 0.15552501 693.25 2.15568474e-01 -2.72810880e-02 2.17287885e-01 -0.12588495 0.44057197 693.50 2.19479785e-01 -7.74616939e-02 2.32748126e-01 -0.33928548 0.52157865 693.75 2.41068073e-01 -2.30392832e-01 3.33458653e-01 -0.76275913 0.68569543 694.00 1.90711515e-01 -2.61379325e-01 3.23558393e-01 -0.94045669 0.68241913 694.25 1.06656702e-01 -2.79335384e-01 2.99004864e-01 -1.20605722 0.68536063 694.50 4.43483713e-02 -2.74518581e-01 2.78077740e-01 -1.41063050 0.60559774 694.75 -7.54023812e-02 -2.13898829e-01 2.26799973e-01 -1.90970924 0.54782860 695.00 -1.39545799e-01 -1.25686758e-01 1.87803598e-01 -2.40839942 0.41241497 695.25 -1.74785987e-01 4.31200974e-02 1.80026343e-01 2.89972015 0.44846934 695.50 -1.01018437e-01 9.60669686e-02 1.39404401e-01 2.38131267 0.21551256 695.75 1.56053388e-02 2.62907639e-01 2.63370373e-01 1.51150915 0.52332116 696.00 1.18492652e-01 2.96404857e-01 3.19212074e-01 1.19049149 0.59368358 696.25 2.72316001e-01 2.97111715e-01 4.03027761e-01 0.82891564 0.75519750 696.50 3.47517132e-01 2.13322702e-01 4.07767988e-01 0.55053969 0.75015426 696.75 3.71657969e-01 1.28256071e-01 3.93165698e-01 0.33229547 0.77316996 697.00 3.50346697e-01 9.40170447e-02 3.62742351e-01 0.26217733 0.71139871 697.25 3.55236672e-01 7.40127613e-02 3.62864964e-01 0.20540921 0.81289528 697.50 3.78549158e-01 9.53859884e-02 3.90381802e-01 0.24683927 0.77888251 697.75 3.99887430e-01 1.01445752e-01 4.12554478e-01 0.24844461 0.79294125 698.00 4.62158909e-01 9.65917464e-02 4.72144917e-01 0.20603535 0.77625721 698.25 5.30074227e-01 1.08266158e-01 5.41017788e-01 0.20147602 0.81531351 698.50 6.17432250e-01 2.61252507e-02 6.17984719e-01 0.04228752 0.85958724 698.75 6.22719485e-01 -4.80782924e-02 6.24572717e-01 -0.07705412 0.88224081 699.00 5.65180128e-01 -1.55824224e-01 5.86267657e-01 -0.26902356 0.82587817 699.25 5.51107534e-01 -2.12068680e-01 5.90502023e-01 -0.36733860 0.85300526 699.50 5.20715761e-01 -2.25781138e-01 5.67557949e-01 -0.40913035 0.79613303 699.75 5.36702324e-01 -2.43511717e-01 5.89361808e-01 -0.42594184 0.81798182 700.00 5.83175657e-01 -3.58464493e-01 6.84536806e-01 -0.55114136 0.84648793 700.25 5.46101929e-01 -4.11315057e-01 6.83671992e-01 -0.64553555 0.85670890 700.50 3.86769493e-01 -4.98476349e-01 6.30927342e-01 -0.91092210 0.85631149 700.75 3.17411667e-01 -5.18427513e-01 6.07879308e-01 -1.02141193 0.91065130 701.00 1.88138345e-01 -4.71205051e-01 5.07375834e-01 -1.19091886 0.83350969 701.25 9.72081538e-02 -4.46493863e-01 4.56953164e-01 -1.35642713 0.80474230 701.50 -2.95818603e-03 -3.58235170e-01 3.58247384e-01 -1.57905380 0.72944266 701.75 -5.01516450e-02 -3.01433442e-01 3.05577007e-01 -1.73566332 0.64066521 702.00 -1.42276985e-01 -9.13806957e-02 1.69095156e-01 -2.57066846 0.26073565 702.25 -1.25018349e-01 2.14441988e-02 1.26844161e-01 2.97171739 0.14619732 702.50 -6.64326843e-03 3.06406951e-01 3.06478959e-01 1.59247412 0.39113561 702.75 4.56094240e-02 4.17127189e-01 4.19613287e-01 1.46188721 0.57196638 703.00 3.23954862e-01 4.86384426e-01 5.84394184e-01 0.98322288 0.70898669 703.25 4.83928434e-01 4.96483798e-01 6.93312982e-01 0.79820367 0.77340697 703.50 7.01448316e-01 4.49728503e-01 8.33237941e-01 0.57012346 0.83182905 703.75 8.14937955e-01 3.92673594e-01 9.04608436e-01 0.44901822 0.84339325 704.00 9.41233488e-01 3.34365242e-01 9.98859647e-01 0.34133670 0.90343893 704.25 9.84116735e-01 2.76135034e-01 1.02212343e+00 0.27355735 0.89853565 704.50 1.03737384e+00 1.46226399e-01 1.04762906e+00 0.14003564 0.91293659 704.75 1.03905765e+00 1.17686385e-01 1.04570115e+00 0.11278198 0.90863732 705.00 1.13230904e+00 2.96481280e-02 1.13269712e+00 0.02617780 0.91468182 705.25 1.16157233e+00 -1.49965213e-02 1.16166913e+00 -0.01290982 0.88337272 705.50 1.24957072e+00 4.29646483e-02 1.25030914e+00 0.03436999 0.84751681 705.75 1.36730332e+00 -6.35996751e-02 1.36878168e+00 -0.04648118 0.86527431 706.00 1.43499427e+00 -9.76186875e-02 1.43831080e+00 -0.06792259 0.91152535 706.25 1.52098322e+00 -1.91935331e-01 1.53304570e+00 -0.12552811 0.90400998 706.50 1.63638685e+00 -3.86933443e-01 1.68151105e+00 -0.23219129 0.90639340 706.75 1.82528144e+00 -4.86617350e-01 1.88903382e+00 -0.26053878 0.90809637 707.00 2.08184489e+00 -6.25745693e-01 2.17385276e+00 -0.29198210 0.93492711 707.25 2.15984167e+00 -7.95984448e-01 2.30184867e+00 -0.35309365 0.91822514 707.50 2.14861179e+00 -1.15321544e+00 2.43853203e+00 -0.49259482 0.89059537 707.75 2.20973537e+00 -1.49796013e+00 2.66960951e+00 -0.59573322 0.86844501 708.00 2.19594061e+00 -1.96176652e+00 2.94460236e+00 -0.72913471 0.89549447 708.25 1.90348785e+00 -2.22659003e+00 2.92932913e+00 -0.86347065 0.87316411 708.50 1.64693931e+00 -2.62713450e+00 3.10068456e+00 -1.01083498 0.88597164 708.75 1.29183667e+00 -2.76832875e+00 3.05491179e+00 -1.13418402 0.89224927 709.00 1.00439367e+00 -2.92890930e+00 3.09633918e+00 -1.24043903 0.91177044 709.25 5.74213993e-01 -2.96839800e+00 3.02342660e+00 -1.37971404 0.90460040 709.50 1.78250658e-01 -3.07738841e+00 3.08254647e+00 -1.51293827 0.92348403 709.75 -1.70639817e-01 -2.85013088e+00 2.85523449e+00 -1.63059581 0.89790375 710.00 -4.06526656e-01 -2.69409472e+00 2.72459360e+00 -1.72056191 0.89314784 710.25 -4.42159918e-01 -2.63528182e+00 2.67211820e+00 -1.73703260 0.90072148 710.50 -5.62138329e-01 -2.69581940e+00 2.75380495e+00 -1.77637277 0.90601661 710.75 -7.72372918e-01 -2.57026627e+00 2.68380860e+00 -1.86271459 0.91085627 711.00 -8.89510054e-01 -2.56497272e+00 2.71483208e+00 -1.90460970 0.93507584 711.25 -1.07469548e+00 -2.47467156e+00 2.69795658e+00 -1.98049923 0.93279654 711.50 -1.38763856e+00 -2.47695642e+00 2.83916429e+00 -2.08145151 0.93804240 711.75 -1.83721983e+00 -2.35251437e+00 2.98491215e+00 -2.23381927 0.90420121 712.00 -2.05113863e+00 -2.13928022e+00 2.96372899e+00 -2.33516351 0.89886223 712.25 -2.12036122e+00 -1.85409268e+00 2.81666317e+00 -2.42308953 0.92813579 712.50 -2.20516947e+00 -1.67908112e+00 2.77165759e+00 -2.49081670 0.93591459 712.75 -2.52551691e+00 -1.30896717e+00 2.84457918e+00 -2.66341503 0.91885845 713.00 -2.74675291e+00 -1.05847939e+00 2.94364233e+00 -2.77377327 0.93428017 713.25 -2.90381200e+00 -4.29677719e-01 2.93542962e+00 -2.99468840 0.91395257 713.50 -2.77598176e+00 -2.66766148e-02 2.77610994e+00 -3.13198315 0.90534216 713.75 -2.52514899e+00 4.67529986e-01 2.56806575e+00 2.95851637 0.90028822 714.00 -2.31015922e+00 7.92953148e-01 2.44245989e+00 2.81094729 0.88130570 714.25 -1.76605543e+00 1.30915180e+00 2.19836990e+00 2.50369201 0.88461708 714.50 -1.48161337e+00 1.40904056e+00 2.04464508e+00 2.38129523 0.87216673 714.75 -8.55069844e-01 1.54452676e+00 1.76541988e+00 2.07640908 0.82442613 715.00 -4.67941483e-01 1.47247824e+00 1.54504414e+00 1.87849489 0.77460603 715.25 -2.21109837e-02 1.25286454e+00 1.25305964e+00 1.58844284 0.72628250 715.50 2.76479276e-01 1.03497534e+00 1.07126782e+00 1.30975572 0.66548681 715.75 3.68122808e-01 5.96870513e-01 7.01262299e-01 1.01814806 0.46330004 716.00 3.27424734e-01 3.95039297e-01 5.13091613e-01 0.87871518 0.30149936 716.25 1.22425495e-01 2.16235267e-01 2.48486805e-01 1.05562484 0.10799707 716.50 1.02317056e-01 2.04427714e-01 2.28603304e-01 1.10674495 0.09701505 716.75 4.60330386e-02 2.15338009e-01 2.20203312e-01 1.36019509 0.08514179 717.00 -1.27766686e-02 2.41295877e-01 2.41633904e-01 1.62369714 0.08222901 717.25 1.82843970e-02 4.18902856e-01 4.19301708e-01 1.52717572 0.21905753 717.50 2.48839849e-01 4.78021387e-01 5.38911604e-01 1.09083463 0.34381876 717.75 4.35571499e-01 5.02277717e-01 6.64834894e-01 0.85640539 0.47414647 718.00 5.65630707e-01 3.64044336e-01 6.72656209e-01 0.57186845 0.40935208 718.25 8.09790480e-01 3.32115082e-01 8.75249135e-01 0.38920399 0.43126738 718.50 1.22585624e+00 2.29507271e-01 1.24715561e+00 0.18507939 0.47590784 718.75 1.60065231e+00 -4.48922965e-01 1.66241380e+00 -0.27343754 0.66066527 719.00 1.47008579e+00 -1.16690416e+00 1.87691703e+00 -0.67092816 0.71932656 719.25 1.21388166e+00 -1.55756590e+00 1.97472029e+00 -0.90877721 0.77349936 719.50 7.97777619e-01 -1.89171275e+00 2.05305291e+00 -1.17170512 0.79695425 719.75 3.99857121e-01 -2.23135538e+00 2.26689933e+00 -1.39347916 0.85435564 720.00 -1.88699609e-01 -2.17571554e+00 2.18388316e+00 -1.65730975 0.84804087 720.25 -4.61617345e-01 -1.97679559e+00 2.02997817e+00 -1.80020338 0.85510694 720.50 -7.27510942e-01 -1.74730736e+00 1.89271107e+00 -1.96532712 0.80273919 720.75 -9.37035219e-01 -1.51968193e+00 1.78534820e+00 -2.12333206 0.81205893 721.00 -1.26529688e+00 -1.31566526e+00 1.82536333e+00 -2.33668162 0.84802417 721.25 -1.41511648e+00 -1.13708220e+00 1.81535412e+00 -2.46470570 0.84133055 721.50 -1.45855052e+00 -6.97921262e-01 1.61693033e+00 -2.69528981 0.87181562 721.75 -1.53453431e+00 -5.36489833e-01 1.62561277e+00 -2.80526456 0.89612318 722.00 -1.50791281e+00 8.83636704e-02 1.51049964e+00 3.08305961 0.77836661 722.25 -1.36982571e+00 4.50698124e-01 1.44206493e+00 2.82373038 0.79167102 722.50 -6.67493575e-01 7.83911728e-01 1.02959471e+00 2.27615520 0.64473638 722.75 -3.92039013e-01 8.54464437e-01 9.40108538e-01 2.00095456 0.66395441 723.00 9.00613991e-02 6.22191491e-01 6.28675836e-01 1.42704606 0.36860074 723.25 2.33191977e-01 4.31118739e-01 4.90144739e-01 1.07496678 0.28052103 723.50 3.33316523e-01 2.07866636e-01 3.92821133e-01 0.55761452 0.25660014 723.75 3.81099726e-01 9.49064925e-02 3.92739409e-01 0.24406855 0.27678808 724.00 3.05924152e-01 -7.04956346e-02 3.13941430e-01 -0.22648150 0.27508483 724.25 2.40952936e-01 -1.13753299e-01 2.66454743e-01 -0.44107756 0.27221412 724.50 2.76897531e-01 -2.24000171e-01 3.56157717e-01 -0.68018302 0.43366242 724.75 2.70756946e-01 -2.66960490e-01 3.80233122e-01 -0.77833796 0.48074355 725.00 1.21535999e-01 -3.08737550e-01 3.31797942e-01 -1.19577194 0.45427380 725.25 4.66347054e-02 -2.60530225e-01 2.64671105e-01 -1.39367294 0.32104292 725.50 2.28276773e-02 -3.66217166e-02 4.31538292e-02 -1.01339365 0.01229795 725.75 8.32737541e-02 4.17934546e-02 9.31730163e-02 0.46515070 0.05432697 726.00 2.49418488e-01 1.22835871e-01 2.78025598e-01 0.45762081 0.30793615 726.25 3.61048716e-01 2.01725509e-01 4.13581137e-01 0.50951415 0.44744746 726.50 5.64679040e-01 3.49326920e-01 6.63996774e-01 0.55400491 0.65310782 726.75 7.35780680e-01 3.46846194e-01 8.13434381e-01 0.44050605 0.73409298 727.00 9.38664197e-01 4.82813626e-01 1.05555647e+00 0.47507145 0.81399158 727.25 1.15387320e+00 5.99833842e-01 1.30047068e+00 0.47939634 0.81258001 727.50 1.55905010e+00 6.86201623e-01 1.70338190e+00 0.41462487 0.81768897 727.75 1.88827094e+00 7.03298899e-01 2.01499292e+00 0.35653894 0.77445441 728.00 2.72881238e+00 6.42622605e-01 2.80345873e+00 0.23128133 0.81386226 728.25 3.10052004e+00 5.90598007e-01 3.15626845e+00 0.18822859 0.72535447 728.50 3.69229282e+00 6.82580514e-01 3.75485585e+00 0.18280249 0.62167231 728.75 3.32923984e+00 8.79231464e-01 3.44338291e+00 0.25819876 0.35449352 729.00 2.65845106e+00 7.19044052e-01 2.75397647e+00 0.26415433 0.14996725 729.25 1.15711384e+00 -4.85249874e-03 1.15712402e+00 -0.00419360 0.03349809 729.50 -5.39746185e-01 -6.94832201e-02 5.44200204e-01 -3.01356366 0.00752113 729.75 -8.62308071e-01 4.95309076e-01 9.94437675e-01 2.62021000 0.05048582 730.00 -8.75389924e-01 2.72891032e-01 9.16938947e-01 2.83940347 0.07954393 730.25 -7.10910310e-01 -4.64334343e-01 8.49117101e-01 -2.56300298 0.10346589 730.50 -7.40495690e-01 -9.60536058e-01 1.21283279e+00 -2.22755185 0.20385280 730.75 -8.87535306e-01 -1.27615714e+00 1.55444394e+00 -2.17847888 0.31240048 731.00 -8.65060391e-01 -1.20747472e+00 1.48537021e+00 -2.19245837 0.30160179 731.25 -8.16681067e-01 -1.59244351e+00 1.78964921e+00 -2.04466923 0.38659665 731.50 -1.20484979e+00 -1.92104211e+00 2.26761236e+00 -2.13096571 0.54676012 731.75 -1.34278619e+00 -1.83707654e+00 2.27550543e+00 -2.20198471 0.58273516 732.00 -1.44753364e+00 -1.83875517e+00 2.34016542e+00 -2.23770553 0.61364473 732.25 -1.57847052e+00 -1.86624061e+00 2.44426332e+00 -2.27284833 0.64898072 732.50 -1.98473751e+00 -1.47207554e+00 2.47107049e+00 -2.50342613 0.64264675 732.75 -2.21907487e+00 -8.14506262e-01 2.36383454e+00 -2.78981205 0.65009741 733.00 -2.40196057e+00 -4.06845772e-01 2.43617283e+00 -2.97380446 0.64539926 733.25 -2.36671829e+00 -2.23345991e-01 2.37723346e+00 -3.04750182 0.64608229 733.50 -2.35919892e+00 -1.15648816e-01 2.36203179e+00 -3.09261149 0.71250353 733.75 -2.45157668e+00 2.32610969e-02 2.45168703e+00 3.13210472 0.74073084 734.00 -2.25868090e+00 7.47754234e-02 2.25991831e+00 3.10849895 0.71978180 734.25 -2.17183315e+00 4.75286459e-01 2.22323108e+00 2.92614797 0.70907952 734.50 -2.13637283e+00 6.88967787e-01 2.24471946e+00 2.82962886 0.73130541 734.75 -1.89628598e+00 9.97226512e-01 2.14251284e+00 2.65745289 0.83145630 735.00 -1.77405663e+00 1.05399160e+00 2.06353465e+00 2.60551245 0.84391440 735.25 -1.63610711e+00 1.01890647e+00 1.92743790e+00 2.58460381 0.76891933 735.50 -1.57533477e+00 1.11192715e+00 1.92822759e+00 2.52696100 0.77558005 735.75 -1.29451844e+00 1.20280307e+00 1.76706345e+00 2.39290349 0.72830173 736.00 -1.34057015e+00 1.18754703e+00 1.79092051e+00 2.41664923 0.71602334 736.25 -1.21301645e+00 1.10936455e+00 1.64380614e+00 2.40079662 0.67852320 736.50 -9.82944962e-01 1.07957799e+00 1.46002378e+00 2.30937687 0.63074619 736.75 -7.56375374e-01 9.16884387e-01 1.18860451e+00 2.26056117 0.63687910 737.00 -6.03011699e-01 8.24163986e-01 1.02120977e+00 2.20245921 0.55659772 737.25 -5.24814263e-01 8.02351656e-01 9.58748242e-01 2.15004495 0.58531785 737.50 -6.81307219e-01 8.34163734e-01 1.07703698e+00 2.25567043 0.71672221 737.75 -6.89157447e-01 8.50434631e-01 1.09461274e+00 2.25182196 0.64037847 738.00 -6.44090750e-01 7.89264576e-01 1.01872050e+00 2.25525619 0.56046144 738.25 -6.72292655e-01 7.58151916e-01 1.01329746e+00 2.29624364 0.56358004 738.50 -6.99974405e-01 7.36288655e-01 1.01591592e+00 2.33091603 0.58561408 738.75 -7.28010287e-01 9.62733037e-01 1.20700202e+00 2.21824807 0.75030794 739.00 -6.82694730e-01 9.02262420e-01 1.13143695e+00 2.21853837 0.72425505 739.25 -8.09729301e-01 6.66118011e-01 1.04851073e+00 2.45319678 0.71280693 739.50 -7.35351188e-01 4.81012620e-01 8.78700467e-01 2.56232210 0.62445501 739.75 -6.20016603e-01 4.36960604e-01 7.58521692e-01 2.52768167 0.50179043 740.00 -4.52890570e-01 4.36351307e-01 6.28897711e-01 2.37479163 0.34947825 740.25 -2.97262109e-01 4.29690326e-01 5.22492620e-01 2.17600139 0.33513787 740.50 -4.04001058e-01 3.85707883e-01 5.58558346e-01 2.37935480 0.40756965 740.75 -5.42489304e-01 3.92545107e-01 6.69616537e-01 2.51520292 0.50456197 741.00 -4.36099497e-01 3.72435401e-01 5.73490104e-01 2.43477243 0.42796423 741.25 -3.71299963e-01 3.22638557e-01 4.91893587e-01 2.42620340 0.37106068 741.50 -3.42824146e-01 1.98214511e-01 3.96001752e-01 2.61737083 0.23382985 741.75 -3.92083951e-01 1.89189813e-01 4.35341946e-01 2.69202355 0.26804712 742.00 -4.75981746e-01 -1.09078654e-01 4.88320361e-01 -2.91631687 0.27773205 742.25 -5.70761415e-01 -1.90278054e-01 6.01643026e-01 -2.81980386 0.40986073 742.50 -7.65518690e-01 -2.64459576e-01 8.09912175e-01 -2.80896402 0.41806354 742.75 -9.82277633e-01 -3.49591086e-01 1.04263286e+00 -2.79967279 0.43735487 743.00 -1.32927584e+00 -3.98006507e-01 1.38758187e+00 -2.85067169 0.48498692 743.25 -1.38476545e+00 -1.72974768e-01 1.39552700e+00 -3.01732363 0.48274107 743.50 -1.89204307e+00 5.80384816e-01 1.97905875e+00 2.84395447 0.57023384 743.75 -2.16708862e+00 7.85113509e-01 2.30492436e+00 2.79401171 0.59910159 744.00 -2.07176753e+00 1.41919945e+00 2.51124426e+00 2.54099219 0.56512541 744.25 -1.97093065e+00 1.49057473e+00 2.47110919e+00 2.49408467 0.54863521 744.50 -1.87345082e+00 2.01473495e+00 2.75117701e+00 2.31987370 0.56466875 744.75 -1.44244227e+00 2.46532060e+00 2.85629924e+00 2.10018282 0.52628074 745.00 -8.60779454e-01 3.66149694e+00 3.76131641e+00 1.80169309 0.70979564 745.25 -6.20793500e-01 3.96363946e+00 4.01195991e+00 1.72615627 0.80307496 745.50 2.12910754e-02 4.28695851e+00 4.28701138e+00 1.56582989 0.82659771 745.75 5.22928489e-01 4.28208445e+00 4.31389632e+00 1.44927795 0.80903173 746.00 1.55446538e+00 4.18336441e+00 4.46283547e+00 1.21502510 0.80438473 746.25 2.11602682e+00 3.71438483e+00 4.27483615e+00 1.05296609 0.75201034 746.50 2.92822157e+00 2.93590372e+00 4.14656632e+00 0.78670819 0.77662818 746.75 3.08313049e+00 2.44181945e+00 3.93296019e+00 0.66983986 0.74567717 747.00 3.27507342e+00 1.78891926e+00 3.73180091e+00 0.49993850 0.76503285 747.25 3.28217986e+00 1.46548287e+00 3.59448809e+00 0.41993686 0.79119468 747.50 3.95480650e+00 9.96206698e-01 4.07834798e+00 0.24676394 0.80071604 747.75 4.33946659e+00 4.12903443e-01 4.35906636e+00 0.09486513 0.83142479 748.00 4.25104884e+00 -6.68945228e-01 4.30335961e+00 -0.15608015 0.83469601 748.25 3.59959147e+00 -1.86182344e+00 4.05258501e+00 -0.47733788 0.76149321 748.50 2.80716965e+00 -2.95952114e+00 4.07908897e+00 -0.81181124 0.74404299 748.75 1.57846389e+00 -3.48034326e+00 3.82156217e+00 -1.14500506 0.73359598 749.00 2.44867665e-01 -3.47140471e+00 3.48003029e+00 -1.50037448 0.71855223 749.25 -3.18241559e-01 -2.88926621e+00 2.90673992e+00 -1.68050026 0.58016065 749.50 -1.16236730e+00 -2.35111545e+00 2.62275458e+00 -2.02994565 0.56021130 749.75 -1.92235790e+00 -1.65019057e+00 2.53349340e+00 -2.43223058 0.55230280 750.00 -2.75398274e+00 -7.72258807e-01 2.86021058e+00 -2.86819891 0.58342429 750.25 -2.40087495e+00 -3.07644901e-01 2.42050531e+00 -3.01414849 0.60561033 750.50 -2.19090335e+00 -1.40171034e-02 2.19094818e+00 -3.13519488 0.63839293 750.75 -1.50542568e+00 1.74784540e-01 1.51553823e+00 3.02600709 0.42762089 751.00 -1.19666626e+00 2.44563148e-01 1.22140135e+00 2.93999835 0.38954378 751.25 -1.30983456e+00 2.12611909e-01 1.32697792e+00 2.98067645 0.51163264 751.50 -1.17865687e+00 2.16400947e-01 1.19835779e+00 2.96001527 0.55794475 751.75 -9.13470781e-01 4.10620128e-01 1.00151773e+00 2.71914093 0.45475413 752.00 -5.57594543e-01 5.83435237e-01 8.07036771e-01 2.33355154 0.37286827 752.25 -3.29206884e-01 7.08060942e-01 7.80850478e-01 2.00600586 0.42840050 752.50 -9.56464144e-02 6.19420913e-01 6.26761920e-01 1.72399899 0.29796015 752.75 1.66589540e-01 4.59314638e-01 4.88591866e-01 1.22286004 0.17905863 753.00 2.11957170e-01 3.86665473e-01 4.40949011e-01 1.06936166 0.16170975 753.25 3.13506075e-01 1.37799513e-01 3.42454033e-01 0.41412423 0.07119018 753.50 2.04432092e-01 -7.01947994e-03 2.04552568e-01 -0.03432300 0.01748890 753.75 -2.75792177e-02 -1.93255968e-01 1.95213940e-01 -1.71254745 0.01091219 754.00 -1.04640614e-01 -1.09264266e-01 1.51288922e-01 -2.33458240 0.00665515 754.25 -4.15723033e-01 -2.00487912e-01 4.61542027e-01 -2.69223492 0.07990272 754.50 -4.77028390e-01 -1.54757481e-01 5.01503702e-01 -2.82788557 0.11361504 754.75 -2.52035872e-01 8.01918197e-02 2.64485932e-01 2.83354496 0.04049231 755.00 -1.77612923e-01 6.17578599e-02 1.88043568e-01 2.80695902 0.02470038 755.25 -3.07517076e-01 1.27906447e-01 3.33056768e-01 2.74742698 0.10041898 755.50 -4.46061207e-01 1.45930982e-01 4.69325528e-01 2.82541321 0.22310104 755.75 -6.60490635e-01 2.00792546e-01 6.90337255e-01 2.84646548 0.39054955 756.00 -6.07771409e-01 3.03068265e-01 6.79143916e-01 2.67902161 0.43416805 756.25 -4.60731549e-01 3.86321475e-01 6.01263538e-01 2.44381539 0.46037381 756.50 -4.33905006e-01 4.85085466e-01 6.50831364e-01 2.30055992 0.49941446 756.75 -3.65718751e-01 5.05197587e-01 6.23678448e-01 2.19739120 0.43111221 757.00 -2.91047397e-01 4.96509917e-01 5.75526442e-01 2.10099690 0.42497049 757.25 -3.51541886e-01 5.95770393e-01 6.91754334e-01 2.10387694 0.63916777 757.50 -3.33012867e-01 6.04641660e-01 6.90281904e-01 2.07422339 0.65350113 757.75 -1.73586748e-01 5.84620958e-01 6.09847541e-01 1.85942676 0.69643531 758.00 -1.15615523e-01 5.35878317e-01 5.48208464e-01 1.78328884 0.69568423 758.25 9.67460965e-03 4.79524059e-01 4.79621644e-01 1.55062362 0.60241499 758.50 8.34625691e-02 3.75900818e-01 3.85055094e-01 1.35230724 0.35984622 758.75 5.76017555e-02 8.65988392e-02 1.04006352e-01 0.98384015 0.03532342 759.00 -1.61107567e-01 -9.08714456e-04 1.61110129e-01 -3.13595229 0.05793502 759.25 -4.44959955e-01 -1.20444170e-01 4.60973058e-01 -2.87724209 0.30337553 759.50 -5.71174631e-01 -1.20895269e-01 5.83828849e-01 -2.93301036 0.35781770 759.75 -7.01729670e-01 -2.31035006e-03 7.01733473e-01 -3.13830030 0.42847707 760.00 -8.42546072e-01 1.10656130e-01 8.49781538e-01 3.01100466 0.42560290 760.25 -9.89908450e-01 1.90719285e-01 1.00811338e+00 2.95126121 0.52801332 760.50 -1.05420754e+00 4.18275246e-01 1.13415507e+00 2.76387605 0.59523573 760.75 -9.77112905e-01 4.24679936e-01 1.06541198e+00 2.73159594 0.61890104 761.00 -1.17943987e+00 2.58920851e-01 1.20752574e+00 2.92549198 0.57229131 761.25 -1.48927209e+00 1.35028650e-01 1.49538092e+00 3.05117233 0.65526599 761.50 -1.78044205e+00 3.89923466e-01 1.82263935e+00 2.92599282 0.64241847 761.75 -2.37958634e+00 2.40959644e-01 2.39175515e+00 3.04067550 0.70745039 762.00 -2.79700703e+00 5.54397818e-01 2.85142162e+00 2.94591779 0.76760110 762.25 -2.93603026e+00 1.22658590e+00 3.18194699e+00 2.74586163 0.74193877 762.50 -3.11338832e+00 2.27392645e+00 3.85537655e+00 2.51077335 0.72973020 762.75 -3.03239769e+00 2.84259605e+00 4.15641529e+00 2.38848995 0.75843543 763.00 -1.89522275e+00 3.81857839e+00 4.26302829e+00 2.03149265 0.76867108 763.25 -1.02842439e+00 4.04651322e+00 4.17515580e+00 1.81967775 0.78877608 763.50 -6.01500653e-01 3.07099784e+00 3.12934990e+00 1.76421268 0.62062193 763.75 -7.68010691e-01 2.72589004e+00 2.83201641e+00 1.84542407 0.57119790 764.00 -1.87161032e+00 2.47841507e+00 3.10571513e+00 2.21759433 0.66314453 764.25 -2.49749805e+00 2.75797486e+00 3.72074211e+00 2.30667205 0.74501930 764.50 -3.01197817e+00 3.86954205e+00 4.90360767e+00 2.23221527 0.81769267 764.75 -2.87460328e+00 4.62003688e+00 5.44133116e+00 2.12738217 0.83835977 765.00 -2.58155729e+00 4.66583075e+00 5.33239296e+00 2.07616191 0.90967781 765.25 -2.79383621e+00 4.62725744e+00 5.40527817e+00 2.11398913 0.93567225 765.50 -3.67825034e+00 4.67862162e+00 5.95138856e+00 2.23705498 0.92142077 765.75 -4.48677081e+00 5.08999045e+00 6.78521297e+00 2.29328974 0.91994507 766.00 -5.01654444e+00 6.49916039e+00 8.21004287e+00 2.22815156 0.96097459 766.25 -5.16836151e+00 7.10802661e+00 8.78840162e+00 2.19949025 0.96584137 766.50 -5.96723698e+00 7.89141372e+00 9.89354980e+00 2.21823348 0.96517725 766.75 -6.31693277e+00 8.13056032e+00 1.02960988e+01 2.23131538 0.95946206 767.00 -6.31644497e+00 9.04132097e+00 1.10291868e+01 2.18059532 0.95437762 767.25 -6.19462677e+00 9.59048371e+00 1.14171265e+01 2.14429371 0.94776469 767.50 -6.13275397e+00 1.00025152e+01 1.17329017e+01 2.12080793 0.94615046 767.75 -5.55136467e+00 9.93895145e+00 1.13842174e+01 2.08017732 0.92173396 768.00 -4.30227407e+00 9.83650371e+00 1.07362176e+01 1.98310468 0.90401607 768.25 -3.72103178e+00 8.91836982e+00 9.66350856e+00 1.96606929 0.88377950 768.50 -2.73740372e+00 7.79471837e+00 8.26141716e+00 1.90852821 0.83842097 768.75 -2.30049056e+00 6.80391809e+00 7.18230869e+00 1.89684205 0.80364292 769.00 -1.37102517e+00 5.09520114e+00 5.27643674e+00 1.83365202 0.82955008 769.25 -1.33739571e+00 4.28183618e+00 4.48583865e+00 1.87353691 0.86187472 769.50 -1.50851958e+00 3.75139857e+00 4.04334299e+00 1.95313060 0.90446188 769.75 -1.74133312e+00 2.88065883e+00 3.36607135e+00 2.11451169 0.86728478 770.00 -1.82458758e+00 2.20520202e+00 2.86217326e+00 2.26202365 0.91685479 770.25 -2.09156233e+00 1.87073870e+00 2.80611765e+00 2.41186806 0.89953501 770.50 -2.26997977e+00 1.42234668e+00 2.67878297e+00 2.58185077 0.91702003 770.75 -2.33456521e+00 1.17580709e+00 2.61394664e+00 2.67502818 0.88641797 771.00 -2.31932437e+00 1.03648912e+00 2.54038880e+00 2.72132577 0.91547956 771.25 -2.26646932e+00 8.57314921e-01 2.42319459e+00 2.77996688 0.91255482 771.50 -2.21984000e+00 6.32222633e-01 2.30811505e+00 2.86413340 0.91283314 771.75 -2.21698710e+00 5.47139403e-01 2.28350461e+00 2.89963355 0.83104359 772.00 -2.20430549e+00 3.32599154e-01 2.22925658e+00 2.99183617 0.84459975 772.25 -2.16259750e+00 3.20214500e-01 2.18617595e+00 2.99459136 0.84600507 772.50 -2.22042289e+00 2.35834907e-01 2.23291198e+00 3.03577765 0.87211252 772.75 -2.32074487e+00 2.35906698e-01 2.33270417e+00 3.04028933 0.83983338 773.00 -2.39218003e+00 1.74529638e-01 2.39853829e+00 3.06876329 0.81373058 773.25 -2.20444303e+00 5.33732839e-02 2.20508906e+00 3.11738570 0.73434259 773.50 -2.32840537e+00 -9.14978904e-02 2.33020244e+00 -3.10231649 0.75501855 773.75 -2.95266892e+00 9.10947346e-02 2.95407379e+00 3.11075078 0.73799026 774.00 -3.26832844e+00 1.80943986e-01 3.27333340e+00 3.08628626 0.69542617 774.25 -3.08200527e+00 4.99958529e-01 3.12229323e+00 2.98077494 0.66082945 774.50 -3.20634873e+00 4.03792520e-01 3.23167458e+00 3.01631685 0.67299953 774.75 -3.26322585e+00 3.12204541e-01 3.27812670e+00 3.04620938 0.64996182 775.00 -3.07182695e+00 6.62151082e-01 3.14238203e+00 2.92928501 0.58051364 775.25 -3.36878909e+00 1.07536207e+00 3.53626123e+00 2.83260355 0.64337369 775.50 -3.86271383e+00 7.40084748e-01 3.93297388e+00 2.95228971 0.64622284 775.75 -4.59048725e+00 1.23900136e+00 4.75475526e+00 2.87796817 0.80535263 776.00 -4.12218841e+00 1.33081278e+00 4.33168557e+00 2.82931444 0.80466013 776.25 -3.92809701e+00 1.31203479e+00 4.14142263e+00 2.81923068 0.81534703 776.50 -4.09963084e+00 1.37285991e+00 4.32339188e+00 2.81845611 0.80632783 776.75 -4.35980060e+00 1.58336612e+00 4.63841671e+00 2.79323010 0.78396693 777.00 -4.43608131e+00 1.95638666e+00 4.84832612e+00 2.72623417 0.78312102 777.25 -3.92191943e+00 2.33806664e+00 4.56596185e+00 2.60400614 0.81474345 777.50 -3.69875826e+00 2.80044006e+00 4.63931861e+00 2.49354407 0.82881109 777.75 -3.54011566e+00 3.11613007e+00 4.71621516e+00 2.41980596 0.84709153 778.00 -3.37172529e+00 3.21085082e+00 4.65597406e+00 2.38062907 0.83808787 778.25 -3.41827187e+00 3.48634892e+00 4.88254149e+00 2.34633517 0.79194368 778.50 -2.91915018e+00 4.05170399e+00 4.99377042e+00 2.19513193 0.76405150 778.75 -2.20878600e+00 4.21358086e+00 4.75741518e+00 2.05362099 0.69439713 779.00 -1.46067703e+00 4.46996488e+00 4.70256987e+00 1.88663367 0.60765329 779.25 -2.31888450e-01 4.79902281e+00 4.80462196e+00 1.61907870 0.47580816 779.50 7.08339444e-01 3.86423326e+00 3.92861852e+00 1.38950242 0.43390708 779.75 2.01491241e+00 4.42377401e+00 4.86103369e+00 1.14339986 0.50246960 780.00 2.90291452e+00 3.83042758e+00 4.80615108e+00 0.92228598 0.50547634 780.25 3.65910552e+00 1.83865330e+00 4.09508232e+00 0.46563530 0.49575007 780.50 3.44945821e+00 1.01276640e+00 3.59506018e+00 0.28557640 0.47032729 780.75 4.05476024e+00 -1.52899003e-01 4.05764201e+00 -0.03769066 0.50142436 781.00 4.29946675e+00 -1.57094687e+00 4.57747621e+00 -0.35031172 0.59319740 781.25 3.63207365e+00 -2.28945272e+00 4.29343135e+00 -0.56243235 0.59023983 781.50 1.97287208e+00 -2.92926864e+00 3.53169067e+00 -0.97807560 0.51342347 781.75 1.10697974e+00 -3.81332559e+00 3.97075008e+00 -1.28826914 0.75181387 782.00 2.53964929e-01 -3.68603375e+00 3.69477238e+00 -1.50200580 0.78223166 782.25 -4.33048639e-01 -3.48885935e+00 3.51563233e+00 -1.69428799 0.85374138 782.50 -1.09660693e+00 -3.25084042e+00 3.43081772e+00 -1.89613982 0.86031492 782.75 -1.70393426e+00 -2.99632141e+00 3.44693110e+00 -2.08786451 0.87994220 783.00 -1.90881329e+00 -2.45313990e+00 3.10828949e+00 -2.23204661 0.86312370 783.25 -2.07385519e+00 -1.91394857e+00 2.82206918e+00 -2.39627194 0.88680597 783.50 -2.03640167e+00 -1.35473927e+00 2.44586390e+00 -2.55456361 0.77549475 783.75 -2.05674440e+00 -8.64266952e-01 2.23095381e+00 -2.74378518 0.75399275 784.00 -1.96659786e+00 -3.66395301e-01 2.00043812e+00 -2.95739530 0.73443721 784.25 -1.74081847e+00 -9.19020870e-02 1.74324265e+00 -3.08884916 0.76330869 784.50 -1.55858101e+00 3.70071244e-02 1.55902030e+00 3.11785300 0.73243112 784.75 -1.16954721e+00 1.82231166e-01 1.18365910e+00 2.98702210 0.63346434 785.00 -4.63066776e-01 4.82191827e-02 4.65570541e-01 3.03783650 0.20163078 785.25 -3.03311275e-01 -5.97949526e-02 3.09149100e-01 -2.94694807 0.09801530 785.50 -2.90043566e-01 -5.20551909e-01 5.95902308e-01 -2.07913889 0.26639195 785.75 -2.31658738e-01 -7.60509530e-01 7.95009759e-01 -1.86647701 0.35920121 786.00 -8.06649766e-01 -1.22878076e+00 1.46989320e+00 -2.15170192 0.53736489 786.25 -1.11425115e+00 -1.36171848e+00 1.75949789e+00 -2.25657767 0.69527760 786.50 -1.64178972e+00 -1.12539595e+00 1.99047470e+00 -2.54068576 0.84431693 786.75 -1.86445440e+00 -1.01615857e+00 2.12338608e+00 -2.64258353 0.89327890 787.00 -1.93142165e+00 -7.70041790e-01 2.07926765e+00 -2.76221463 0.85189219 787.25 -1.88527706e+00 -6.27151771e-01 1.98685403e+00 -2.82045037 0.84546295 787.50 -1.90645467e+00 -4.81657289e-01 1.96635784e+00 -2.89412562 0.84208208 787.75 -1.91579359e+00 -4.85884595e-01 1.97644856e+00 -2.89320934 0.81686312 788.00 -1.95995938e+00 -4.67566314e-01 2.01495881e+00 -2.90741046 0.80937271 788.25 -2.17797888e+00 -3.01217916e-01 2.19870968e+00 -3.00416287 0.82563430 788.50 -2.54919369e+00 -5.47914877e-03 2.54919958e+00 -3.13944329 0.85544408 788.75 -2.65268541e+00 3.01893112e-01 2.66980885e+00 3.02827361 0.84229180 789.00 -2.73028857e+00 8.26552728e-01 2.85265930e+00 2.84762897 0.91599575 789.25 -2.65616174e+00 1.14130385e+00 2.89098075e+00 2.73576333 0.92113470 789.50 -2.27461387e+00 1.50637414e+00 2.72819195e+00 2.55665058 0.94674174 789.75 -1.93168588e+00 1.60728406e+00 2.51292109e+00 2.44760464 0.95091993 790.00 -1.66769140e+00 1.71659773e+00 2.39330365e+00 2.34174451 0.96592206 790.25 -1.46900174e+00 1.67884320e+00 2.23080268e+00 2.28963103 0.96688630 790.50 -1.28273961e+00 1.62949677e+00 2.07380825e+00 2.23768342 0.98148305 790.75 -1.14598333e+00 1.58459622e+00 1.95556206e+00 2.19692505 0.97955165 791.00 -1.07919511e+00 1.50352116e+00 1.85073984e+00 2.19335476 0.98268899 791.25 -1.10388174e+00 1.55109775e+00 1.90380123e+00 2.18931678 0.97956710 791.50 -1.11122387e+00 1.70891341e+00 2.03843164e+00 2.14734848 0.97919386 791.75 -9.33671602e-01 1.84735744e+00 2.06989665e+00 2.03876199 0.96881793 792.00 -7.40651087e-01 1.95774429e+00 2.09316190e+00 1.93247328 0.97728788 792.25 -4.90770966e-01 1.91804370e+00 1.97983529e+00 1.82129257 0.95791694 792.50 -2.74379724e-01 1.85537914e+00 1.87555751e+00 1.71761558 0.96523306 792.75 -1.58255258e-01 1.77794927e+00 1.78497852e+00 1.65957237 0.95757242 793.00 -1.20723150e-01 1.74725476e+00 1.75142036e+00 1.63977974 0.94801024 793.25 -1.73181658e-01 1.75235602e+00 1.76089281e+00 1.66930435 0.93024640 793.50 -1.71316582e-01 1.78546241e+00 1.79366257e+00 1.66645430 0.92901445 793.75 -9.45982355e-02 2.02017109e+00 2.02238474e+00 1.61758899 0.89443803 794.00 1.17384634e-02 2.29007397e+00 2.29010406e+00 1.56567057 0.89298117 794.25 7.54052346e-01 2.53905713e+00 2.64866118e+00 1.28211133 0.87451118 794.50 1.29031191e+00 2.39960368e+00 2.72451879e+00 1.07743096 0.87032419 794.75 1.99121879e+00 1.53758400e+00 2.51577360e+00 0.65754732 0.87545921 795.00 2.15993587e+00 1.10959621e+00 2.42827649e+00 0.47456105 0.90118360 795.25 2.02178745e+00 3.19499433e-01 2.04687674e+00 0.15673209 0.85504056 795.50 1.74700314e+00 3.07238760e-02 1.74727329e+00 0.01758480 0.85118651 795.75 1.27661540e+00 -8.82903663e-02 1.27966482e+00 -0.06904977 0.82839602 796.00 1.10613252e+00 -9.77732643e-02 1.11044530e+00 -0.08816287 0.80160106 796.25 7.74235767e-01 -3.55497384e-02 7.75051486e-01 -0.04588368 0.71779371 796.50 6.59300126e-01 1.75205558e-02 6.59532885e-01 0.02656822 0.68050433 796.75 5.08602447e-01 2.40768062e-01 5.62712812e-01 0.44213511 0.60331296 797.00 4.77646543e-01 4.09636353e-01 6.29244120e-01 0.70889780 0.64600920 797.25 6.16333295e-01 7.17535694e-01 9.45898622e-01 0.86112440 0.83679069 797.50 8.27976126e-01 7.93913404e-01 1.14710198e+00 0.76439937 0.88228460 797.75 1.31485059e+00 7.05623566e-01 1.49222542e+00 0.49254126 0.90227660 798.00 1.48794699e+00 4.95285425e-01 1.56821360e+00 0.32132897 0.90447137 798.25 1.65854157e+00 1.77803047e-01 1.66804498e+00 0.10679657 0.93676083 798.50 1.71548604e+00 -1.17999657e-02 1.71552662e+00 -0.00687839 0.91486222 798.75 1.81001453e+00 -3.40095404e-01 1.84168876e+00 -0.18573096 0.94340455 799.00 1.78444770e+00 -4.93824543e-01 1.85151729e+00 -0.26998132 0.93552186 799.25 1.76160474e+00 -9.41515655e-01 1.99742409e+00 -0.49083778 0.93423305 799.50 1.70584358e+00 -1.17483091e+00 2.07126290e+00 -0.60310828 0.92746956 799.75 1.52029320e+00 -1.47313613e+00 2.11693682e+00 -0.76964594 0.94361098 800.00 1.33283897e+00 -1.66148827e+00 2.13002417e+00 -0.89471789 0.91367394 800.25 1.03513431e+00 -1.98859883e+00 2.24188054e+00 -1.09085639 0.94895752 800.50 7.49087437e-01 -2.08945238e+00 2.21967188e+00 -1.22656133 0.93976363 800.75 4.09761790e-01 -2.13483345e+00 2.17380279e+00 -1.38116180 0.96124794 801.00 1.88143311e-01 -2.13455582e+00 2.14283141e+00 -1.48288186 0.95642809 801.25 -3.27113678e-02 -2.10069960e+00 2.10095427e+00 -1.58636672 0.95949542 801.50 -2.17415188e-01 -2.01626431e+00 2.02795245e+00 -1.67821198 0.93455442 801.75 -5.53538389e-01 -1.96577250e+00 2.04222091e+00 -1.84527718 0.95628618 802.00 -8.01214775e-01 -1.80743852e+00 1.97706326e+00 -1.98805407 0.94114574 802.25 -1.00416062e+00 -1.58568916e+00 1.87689868e+00 -2.13531658 0.95185479 802.50 -1.19993187e+00 -1.25944504e+00 1.73955118e+00 -2.33200074 0.90275532 802.75 -1.27412179e+00 -9.90773456e-01 1.61400694e+00 -2.48065227 0.90485410 803.00 -1.13001255e+00 -6.85920117e-01 1.32189817e+00 -2.59604037 0.86183689 803.25 -9.82023848e-01 -4.91207663e-01 1.09802359e+00 -2.67778560 0.88128069 803.50 -8.06804056e-01 -4.21411102e-01 9.10230795e-01 -2.66024772 0.85333116 803.75 -6.82225201e-01 -3.86751893e-01 7.84224618e-01 -2.62586879 0.88090538 804.00 -5.98213049e-01 -4.23084702e-01 7.32706979e-01 -2.52601912 0.89721023 804.25 -5.70044106e-01 -4.99020237e-01 7.57609055e-01 -2.42253255 0.90612747 804.50 -6.16451242e-01 -5.94943932e-01 8.56720734e-01 -2.37394679 0.90600505 804.75 -6.30141818e-01 -6.62275529e-01 9.14159498e-01 -2.33133635 0.92045963 805.00 -7.13248497e-01 -6.62310266e-01 9.73333606e-01 -2.39320851 0.92153548 805.25 -8.04448535e-01 -7.04577587e-01 1.06937693e+00 -2.42228050 0.94756821 805.50 -9.22666404e-01 -6.44256137e-01 1.12533518e+00 -2.53203900 0.95776709 805.75 -9.54737454e-01 -5.94722097e-01 1.12481909e+00 -2.58449270 0.96395152 806.00 -1.01726341e+00 -4.78330350e-01 1.12411065e+00 -2.70205742 0.97330673 806.25 -1.02326579e+00 -4.43282037e-01 1.11515552e+00 -2.73279437 0.97705692 806.50 -1.00090360e+00 -3.50564682e-01 1.06052044e+00 -2.80469674 0.97605407 806.75 -1.01027345e+00 -2.70272645e-01 1.04580101e+00 -2.88018979 0.97796096 807.00 -1.01941634e+00 -2.22605633e-01 1.04343804e+00 -2.92660167 0.98103725 807.25 -1.01079166e+00 -2.09169862e-01 1.03220726e+00 -2.93753620 0.97886493 807.50 -9.89694256e-01 -1.38360362e-01 9.99318923e-01 -3.00269178 0.97288781 807.75 -1.02651669e+00 -9.10207764e-02 1.03054417e+00 -3.05315439 0.97025995 808.00 -1.01559107e+00 -8.94989937e-03 1.01563050e+00 -3.13278038 0.98197202 808.25 -9.79864808e-01 1.36457446e-02 9.79959820e-01 3.12766740 0.97974911 808.50 -9.63153928e-01 8.06260523e-02 9.66522659e-01 3.05807691 0.97988300 808.75 -9.51582585e-01 1.10016176e-01 9.57921174e-01 3.02648978 0.97543462 809.00 -9.23504968e-01 1.42088839e-01 9.34371802e-01 2.98893153 0.98215520 809.25 -9.16277587e-01 1.55344509e-01 9.29352749e-01 2.97365088 0.98181975 809.50 -8.87814049e-01 2.23022261e-01 9.15397572e-01 2.89548133 0.97837569 809.75 -8.91776738e-01 2.49170633e-01 9.25932910e-01 2.86913187 0.97229950 810.00 -8.61492837e-01 3.32583433e-01 9.23461774e-01 2.77316551 0.96447544 810.25 -8.46374431e-01 3.81535285e-01 9.28395848e-01 2.71808377 0.96640995 810.50 -7.90500005e-01 4.64158439e-01 9.16696959e-01 2.61065988 0.96284643 810.75 -7.14236870e-01 5.09140219e-01 8.77130589e-01 2.52229777 0.93956002 811.00 -6.15175049e-01 5.58651762e-01 8.30982630e-01 2.40431033 0.91294938 811.25 -5.48808477e-01 5.46996677e-01 7.74852314e-01 2.35784789 0.88568658 811.50 -5.00474629e-01 4.99182257e-01 7.06864753e-01 2.35748730 0.84507346 811.75 -4.30771897e-01 4.54767060e-01 6.26400436e-01 2.32910444 0.77417988 812.00 -3.45632618e-01 5.13148502e-01 6.18694829e-01 2.16355112 0.77473407 812.25 -2.71344178e-01 4.85848947e-01 5.56486174e-01 2.08013816 0.58193324 812.50 -1.34127951e-01 4.94547928e-01 5.12413857e-01 1.83563863 0.49347230 812.75 -4.53464099e-03 4.06044181e-01 4.06069501e-01 1.58196371 0.34387851 813.00 -9.12483014e-03 2.17460657e-01 2.17652016e-01 1.61273256 0.13763930 813.25 -8.12352712e-02 2.58697360e-02 8.52549854e-02 2.83329230 0.01470613 813.50 1.03050666e-02 -1.01293375e-01 1.01816218e-01 -1.46941029 0.01530367 813.75 -3.37584853e-01 -1.46075207e-01 3.67833521e-01 -2.73321256 0.18140953 814.00 -4.49498391e-01 -7.35501336e-02 4.55476043e-01 -2.97940281 0.46289324 814.25 -2.22385507e-01 4.47724276e-02 2.26847711e-01 2.94292050 0.37202981 814.50 -1.66895345e-01 -1.28317451e-02 1.67387903e-01 -3.06485864 0.34406554 814.75 -1.63414301e-01 -1.10674403e-01 1.97365288e-01 -2.54629020 0.44876768 815.00 -1.95590985e-01 -1.52823129e-01 2.48215113e-01 -2.47833356 0.65971582 815.25 -2.65008023e-01 -1.35423315e-01 2.97604984e-01 -2.66917121 0.74404272 815.50 -3.00205706e-01 -1.26980845e-01 3.25956440e-01 -2.74143467 0.81616734 815.75 -3.10159511e-01 -1.34134240e-01 3.37921465e-01 -2.73341311 0.84247746 816.00 -3.31052912e-01 -1.39282127e-01 3.59159493e-01 -2.74334881 0.88306283 816.25 -4.02277832e-01 -1.74465238e-01 4.38480984e-01 -2.73238173 0.82448901 816.50 -4.67741613e-01 -1.95882147e-01 5.07101599e-01 -2.74499978 0.81371243 816.75 -6.45704417e-01 -9.58782472e-02 6.52783910e-01 -2.99418344 0.86024863 817.00 -7.34310452e-01 -2.37035431e-02 7.34692927e-01 -3.10932386 0.89099693 817.25 -8.94981110e-01 2.04789247e-01 9.18112098e-01 2.91664562 0.83302272 817.50 -9.57315591e-01 3.49307608e-01 1.01905297e+00 2.79172158 0.81089588 817.75 -1.10915765e+00 9.40185756e-01 1.45402199e+00 2.43846013 0.65433433 818.00 -9.17506300e-01 1.23317458e+00 1.53705477e+00 2.21045911 0.60944043 818.25 -4.45976647e-01 1.15396629e+00 1.23714727e+00 1.93958726 0.27868676 818.50 -2.19949646e-01 8.50118168e-01 8.78110896e-01 1.82397286 0.12249833 818.75 6.97288621e-03 9.73335752e-02 9.75830211e-02 1.49927944 0.00100822 819.00 -6.82109054e-02 -4.98506664e-01 5.03151688e-01 -1.70678233 0.02976342 819.25 -6.31802647e-01 -1.33240532e+00 1.47461131e+00 -2.01357705 0.23533278 819.50 -1.14219168e+00 -1.52773849e+00 1.90750799e+00 -2.21278250 0.39167496 819.75 -1.47170359e+00 -1.44111378e+00 2.05978649e+00 -2.36669590 0.53393078 820.00 -1.63725231e+00 -8.45976865e-01 1.84289771e+00 -2.66467033 0.61637347 820.25 -1.41577274e+00 -2.95994719e-01 1.44638353e+00 -2.93549195 0.71942825 820.50 -1.09837881e+00 -1.73688415e-01 1.11202683e+00 -2.98475967 0.77472380 820.75 -7.48815540e-01 -2.95854336e-01 8.05142535e-01 -2.76532064 0.81567862 821.00 -5.94455607e-01 -3.83909350e-01 7.07646704e-01 -2.56816388 0.78877305 821.25 -4.61540063e-01 -4.80448685e-01 6.66220811e-01 -2.33612410 0.84305860 821.50 -4.12981261e-01 -5.64598480e-01 6.99517666e-01 -2.20232593 0.86178548 821.75 -3.80697981e-01 -6.56679337e-01 7.59051187e-01 -2.09617951 0.89980209 822.00 -3.68706267e-01 -7.61045125e-01 8.45655955e-01 -2.02194584 0.88290280 822.25 -3.97652330e-01 -9.33777287e-01 1.01492236e+00 -1.97338968 0.88285574 822.50 -4.86315401e-01 -1.07369895e+00 1.17869933e+00 -1.99608798 0.90155082 822.75 -5.59137222e-01 -1.18129780e+00 1.30694259e+00 -2.01287674 0.92760039 823.00 -6.99909763e-01 -1.28175497e+00 1.46040045e+00 -2.07060634 0.90049828 823.25 -9.75895707e-01 -1.37912504e+00 1.68948462e+00 -2.18661774 0.93753275 823.50 -1.21284902e+00 -1.43559136e+00 1.87934172e+00 -2.27228874 0.94740884 823.75 -1.43300344e+00 -1.41163893e+00 2.01152264e+00 -2.36370479 0.96048589 824.00 -1.73443935e+00 -1.27728575e+00 2.15400528e+00 -2.50683584 0.94378658 824.25 -1.93170752e+00 -1.18374679e+00 2.26555741e+00 -2.59181586 0.96122642 824.50 -2.12641626e+00 -9.26443734e-01 2.31947065e+00 -2.73070819 0.96855940 824.75 -2.21359953e+00 -7.66223345e-01 2.34246048e+00 -2.80835749 0.98027915 825.00 -2.28834152e+00 -5.04225706e-01 2.34323505e+00 -2.92471284 0.97440693 825.25 -2.31464471e+00 -3.32473629e-01 2.33840091e+00 -2.99892930 0.98175246 825.50 -2.36651435e+00 -6.08812438e-02 2.36729734e+00 -3.11587220 0.98076603 825.75 -2.42705149e+00 7.52757225e-02 2.42821856e+00 3.11058730 0.98497391 826.00 -2.38882573e+00 4.15551068e-01 2.42470020e+00 2.96935994 0.97176933 826.25 -2.28833067e+00 6.66521552e-01 2.38342364e+00 2.85816436 0.97161709 826.50 -1.93861405e+00 9.75709849e-01 2.17030738e+00 2.67530631 0.96707485 826.75 -1.77637884e+00 1.05234648e+00 2.06469244e+00 2.60677194 0.97404121 827.00 -1.44016956e+00 9.51087965e-01 1.72587853e+00 2.55794108 0.96484333 827.25 -1.37157005e+00 8.64732266e-01 1.62140874e+00 2.57907031 0.97493450 827.50 -1.38025975e+00 7.45268453e-01 1.56861150e+00 2.64649967 0.97324099 827.75 -1.40806869e+00 6.49149937e-01 1.55050091e+00 2.70961114 0.97000702 828.00 -1.62786769e+00 6.58530261e-01 1.75602258e+00 2.75718249 0.97585075 828.25 -1.71570168e+00 7.21034346e-01 1.86105421e+00 2.74374686 0.97568319 828.50 -1.93473340e+00 9.34249196e-01 2.14849130e+00 2.69173246 0.95997557 828.75 -1.97084676e+00 1.19465944e+00 2.30465792e+00 2.59665198 0.95977631 829.00 -1.85261968e+00 1.69863563e+00 2.51347621e+00 2.39952780 0.97009587 829.25 -1.75200193e+00 1.91362288e+00 2.59450636e+00 2.31213206 0.96620650 829.50 -1.27981514e+00 2.30461570e+00 2.63612980e+00 2.07772010 0.95948591 829.75 -9.25854073e-01 2.50694794e+00 2.67245089e+00 1.92457380 0.96267946 830.00 -3.98850293e-01 2.47499985e+00 2.50693156e+00 1.73057428 0.97680213 830.25 -1.73943355e-01 2.38535440e+00 2.39168809e+00 1.64358887 0.97605254 830.50 1.62787679e-01 2.22594370e+00 2.23188826e+00 1.49779430 0.97043371 830.75 2.97753158e-01 1.99326390e+00 2.01538034e+00 1.42251309 0.95805776 831.00 5.42824102e-01 1.78099872e+00 1.86188465e+00 1.27495419 0.96086177 831.25 6.40190830e-01 1.61363036e+00 1.73598595e+00 1.19310392 0.95627959 831.50 7.65092369e-01 1.38505103e+00 1.58231877e+00 1.06611780 0.96583752 831.75 7.75188179e-01 1.25162195e+00 1.47223443e+00 1.01627249 0.95120128 832.00 8.29811341e-01 1.02356896e+00 1.31767989e+00 0.88956262 0.96228799 832.25 8.17897543e-01 8.83173826e-01 1.20372439e+00 0.82375297 0.95042375 832.50 7.95606630e-01 7.41960636e-01 1.08788579e+00 0.75052213 0.94481339 832.75 7.70098143e-01 6.22120767e-01 9.89992625e-01 0.67950686 0.92083195 833.00 6.70039592e-01 5.17842304e-01 8.46825665e-01 0.65796750 0.90368858 833.25 6.26670654e-01 4.51063787e-01 7.72123467e-01 0.62387687 0.88011745 833.50 6.08417660e-01 3.94444806e-01 7.25092238e-01 0.57518805 0.88514072 833.75 5.38676138e-01 3.50857914e-01 6.42863328e-01 0.57731221 0.75536971 834.00 4.61952806e-01 2.48749462e-01 5.24668171e-01 0.49395084 0.64915170 834.25 4.02485393e-01 2.76101250e-01 4.88084411e-01 0.60126176 0.62949510 834.50 3.65172206e-01 2.68995186e-01 4.53551706e-01 0.63488638 0.62322579 834.75 3.01154677e-01 3.69149317e-01 4.76408814e-01 0.88649088 0.61429690 835.00 3.21284366e-01 4.32623935e-01 5.38875786e-01 0.93202150 0.71857591 835.25 4.51464797e-01 3.96395139e-01 6.00790786e-01 0.72053791 0.72147732 835.50 5.00315256e-01 3.54127210e-01 6.12961202e-01 0.61594713 0.78263943 835.75 5.25023001e-01 1.71829040e-01 5.52425896e-01 0.31629186 0.70387987 836.00 5.26086774e-01 5.18749820e-02 5.28638163e-01 0.09828764 0.71273539 836.25 4.84056076e-01 2.75488985e-02 4.84839382e-01 0.05685129 0.68558763 836.50 4.69392873e-01 1.38106934e-02 4.69596001e-01 0.02941398 0.69227195 836.75 5.35705642e-01 -2.48467367e-02 5.36281545e-01 -0.04634811 0.69499044 837.00 5.56763522e-01 -8.47461048e-02 5.63176280e-01 -0.15105260 0.69277703 837.25 7.15854415e-01 -2.42911242e-01 7.55945378e-01 -0.32713827 0.74207309 837.50 7.43528398e-01 -3.81757304e-01 8.35806866e-01 -0.47434180 0.81651873 837.75 5.94801748e-01 -6.27928947e-01 8.64918425e-01 -0.81248434 0.80840489 838.00 4.91729437e-01 -6.90999556e-01 8.48102721e-01 -0.95231388 0.76859871 838.25 1.57436045e-01 -7.89492421e-01 8.05036888e-01 -1.37396404 0.82242111 838.50 9.91923300e-02 -8.36747522e-01 8.42606393e-01 -1.45280188 0.86474317 838.75 -6.78522379e-02 -7.92760073e-01 7.95658507e-01 -1.65617812 0.85810354 839.00 -1.49302984e-01 -7.38846672e-01 7.53780993e-01 -1.77018699 0.84940535 839.25 -2.13010102e-01 -7.19841460e-01 7.50696364e-01 -1.85849894 0.86201215 839.50 -2.78708858e-01 -6.91558816e-01 7.45608627e-01 -1.95389949 0.85053015 839.75 -4.37449794e-01 -6.82166169e-01 8.10378309e-01 -2.14100695 0.78272683 840.00 -5.24277194e-01 -6.62854053e-01 8.45128435e-01 -2.23998786 0.78140596 840.25 -5.94425257e-01 -5.02419673e-01 7.78310294e-01 -2.43988061 0.88037669 840.50 -5.99203493e-01 -4.75400291e-01 7.64885784e-01 -2.47089703 0.88278631 840.75 -5.97599466e-01 -4.77052831e-01 7.64659744e-01 -2.46790022 0.87204103 841.00 -6.09117192e-01 -4.78055683e-01 7.74313237e-01 -2.47616813 0.88268880 841.25 -6.48780885e-01 -4.58712910e-01 7.94565398e-01 -2.52615863 0.89910969 841.50 -6.76590958e-01 -4.32957962e-01 8.03260805e-01 -2.57234264 0.87707583 841.75 -7.51011410e-01 -3.45323824e-01 8.26599469e-01 -2.71060935 0.91541953 842.00 -7.77523365e-01 -3.55802316e-01 8.55066004e-01 -2.71242846 0.90682773 842.25 -8.31906630e-01 -3.71485371e-01 9.11081786e-01 -2.72161399 0.90897022 842.50 -8.69274631e-01 -3.30691053e-01 9.30051050e-01 -2.77807708 0.87900892 842.75 -9.99442856e-01 -2.93384329e-01 1.04161432e+00 -2.85606570 0.90167192 843.00 -9.55062809e-01 -2.89066723e-01 9.97849958e-01 -2.84769017 0.88584362 843.25 -9.35160416e-01 -3.11039914e-01 9.85530736e-01 -2.82049689 0.87940890 843.50 -1.01195916e+00 -2.82533736e-01 1.05066011e+00 -2.86933077 0.88469138 843.75 -1.09775098e+00 -2.63615649e-01 1.12895988e+00 -2.90591381 0.90473769 844.00 -1.20092450e+00 -1.85956806e-01 1.21523643e+00 -2.98796800 0.89409696 844.25 -1.27089380e+00 -9.70170173e-02 1.27459144e+00 -3.06540279 0.88999021 844.50 -1.28531781e+00 6.10872461e-02 1.28676864e+00 3.09410143 0.81273720 844.75 -1.33698543e+00 3.44288604e-01 1.38060301e+00 2.88955730 0.81082071 845.00 -1.28694304e+00 4.55525421e-01 1.36518343e+00 2.80139501 0.76707889 845.25 -1.07554083e+00 6.85292724e-01 1.27530945e+00 2.57429607 0.77561700 845.50 -9.06200277e-01 7.52465064e-01 1.17788056e+00 2.44861653 0.80868523 845.75 -8.50353679e-01 7.26629095e-01 1.11852189e+00 2.43449063 0.88230777 846.00 -7.83582014e-01 6.66836304e-01 1.02891760e+00 2.43651240 0.86118324 846.25 -7.60559072e-01 6.56724345e-01 1.00485669e+00 2.42932704 0.84167862 846.50 -8.40295484e-01 6.70988972e-01 1.07532446e+00 2.46775755 0.81950052 846.75 -8.90933999e-01 7.03358734e-01 1.13511096e+00 2.47331030 0.85124271 847.00 -8.51767670e-01 7.97917410e-01 1.16712482e+00 2.38882566 0.84831212 847.25 -8.20630388e-01 7.72039164e-01 1.12671146e+00 2.38669432 0.83637176 847.50 -7.22976813e-01 7.46368150e-01 1.03911543e+00 2.34027627 0.74919382 847.75 -6.30301523e-01 7.56115450e-01 9.84373193e-01 2.26569483 0.72710650 848.00 -5.08820215e-01 6.63854914e-01 8.36421758e-01 2.22475075 0.58289152 848.25 -4.64155670e-01 7.17634567e-01 8.54657743e-01 2.14490851 0.59525985 848.50 -5.08469224e-01 6.92122361e-01 8.58821468e-01 2.20440227 0.64715122 848.75 -5.91900305e-01 6.45411530e-01 8.75729419e-01 2.31297345 0.69763586 849.00 -7.35906002e-01 6.67160547e-01 9.93308028e-01 2.40515191 0.71565057 849.25 -7.64677820e-01 6.12277844e-01 9.79600085e-01 2.46642478 0.70107536 849.50 -8.02061924e-01 6.99636597e-01 1.06432828e+00 2.42429533 0.78059061 849.75 -8.31838171e-01 7.30982752e-01 1.10738003e+00 2.42063934 0.72324344 850.00 -1.05989696e+00 8.05011889e-01 1.33094918e+00 2.49202716 0.68153221 850.25 -9.51002180e-01 9.56101063e-01 1.34853046e+00 2.35352087 0.64900051 850.50 -8.59970458e-01 1.21588179e+00 1.48926751e+00 2.18639237 0.76463072 850.75 -7.84132096e-01 1.26676502e+00 1.48981769e+00 2.12507199 0.82327032 851.00 -5.99193378e-01 1.37679622e+00 1.50153273e+00 1.98128177 0.81303060 851.25 -5.49540314e-01 1.53178796e+00 1.62738099e+00 1.91525147 0.81573958 851.50 -5.76318063e-01 1.70947944e+00 1.80401287e+00 1.89596064 0.84236962 851.75 -5.49198179e-01 1.73440033e+00 1.81927544e+00 1.87745766 0.85210139 852.00 -5.60720576e-01 1.84354355e+00 1.92693030e+00 1.86605948 0.81630716 852.25 -5.79636030e-01 1.85946389e+00 1.94771247e+00 1.87297237 0.75878390 852.50 -4.87790548e-01 1.81652672e+00 1.88087983e+00 1.83313683 0.70428882 852.75 -2.65189208e-01 1.91247112e+00 1.93076956e+00 1.70858085 0.73523556 853.00 -6.78543395e-03 2.30916317e+00 2.30917314e+00 1.57373480 0.76942533 853.25 2.35936363e-01 2.52440887e+00 2.53541044e+00 1.47760502 0.78676664 853.50 3.03315769e-01 2.57203156e+00 2.58985459e+00 1.45341001 0.77950222 853.75 2.46817092e-01 2.57262839e+00 2.58444104e+00 1.47514941 0.76468828 854.00 4.84291210e-01 2.44586958e+00 2.49335436e+00 1.37532103 0.73749062 854.25 8.19651063e-01 2.46142459e+00 2.59430894e+00 1.24934702 0.71124022 854.50 9.63528510e-01 2.54702361e+00 2.72318131e+00 1.20913926 0.67959402 854.75 9.13703411e-01 2.50203124e+00 2.66364679e+00 1.22065854 0.60826854 855.00 9.12627379e-01 2.75284914e+00 2.90018398e+00 1.25067773 0.62903570 855.25 1.90792386e+00 3.53186847e+00 4.01425813e+00 1.07550636 0.65555277 855.50 2.58160573e+00 3.65223595e+00 4.47252900e+00 0.95548367 0.74349952 855.75 3.08902046e+00 2.78280394e+00 4.15764899e+00 0.73329521 0.69909383 856.00 3.30146271e+00 2.31369970e+00 4.03148389e+00 0.61126971 0.66327013 856.25 4.12994766e+00 1.30430971e+00 4.33101506e+00 0.30590435 0.72179637 856.50 4.69288706e+00 1.35498171e+00 4.88458437e+00 0.28108642 0.77764704 856.75 4.27936096e+00 6.72906406e-01 4.33194336e+00 0.15596749 0.72429699 857.00 4.44160108e+00 4.37970297e-01 4.46314218e+00 0.09828866 0.71808854 857.25 3.92119367e+00 1.72933285e-01 3.92500518e+00 0.04407364 0.59842771 857.50 3.67376940e+00 -3.44632096e-01 3.68989877e+00 -0.09353512 0.63980685 857.75 3.68896007e+00 -8.83716570e-01 3.79333381e+00 -0.23512616 0.71089582 858.00 3.64807220e+00 -1.14204874e+00 3.82265694e+00 -0.30339079 0.74843774 858.25 3.72160987e+00 -1.10325761e+00 3.88169517e+00 -0.28819337 0.77169292 858.50 3.47675469e+00 -1.30150215e+00 3.71237539e+00 -0.35819540 0.79265092 858.75 2.85843481e+00 -1.84030960e+00 3.39961601e+00 -0.57201653 0.80278386 859.00 2.65512238e+00 -2.05895484e+00 3.35990623e+00 -0.65960060 0.79567672 859.25 2.27648679e+00 -1.93287326e+00 2.98636755e+00 -0.70394793 0.66193438 859.50 2.18916263e+00 -1.56862102e+00 2.69314035e+00 -0.62174012 0.59877209 859.75 2.02568140e+00 -1.45946154e+00 2.49668042e+00 -0.62433865 0.56641628 860.00 2.02286959e+00 -1.38940731e+00 2.45406887e+00 -0.60184561 0.58004319 860.25 1.94647590e+00 -1.66486084e+00 2.56135317e+00 -0.70757482 0.57689734 860.50 2.16882988e+00 -1.82140029e+00 2.83219386e+00 -0.69854714 0.62016059 860.75 2.37155256e+00 -2.07034320e+00 3.14810777e+00 -0.71769082 0.66908620 861.00 2.36217078e+00 -2.18612984e+00 3.21854229e+00 -0.74671270 0.63129278 861.25 1.83317313e+00 -2.27831397e+00 2.92425003e+00 -0.89324568 0.54414423 861.50 1.45213011e+00 -3.07917494e+00 3.40440893e+00 -1.13012807 0.64548071 861.75 1.14704185e+00 -3.44828843e+00 3.63406083e+00 -1.24966907 0.78510216 862.00 9.73595214e-01 -3.40267799e+00 3.53922380e+00 -1.29211591 0.75982317 862.25 4.57944879e-01 -3.36648986e+00 3.39749429e+00 -1.43559580 0.74499595 862.50 1.45009727e-01 -3.27918289e+00 3.28238759e+00 -1.52660382 0.72710263 862.75 -3.87245395e-01 -3.00202124e+00 3.02689454e+00 -1.69908280 0.78351247 863.00 -6.11662890e-01 -2.72663889e+00 2.79440354e+00 -1.79147156 0.79629393 863.25 -6.99354914e-01 -2.59285230e+00 2.68551305e+00 -1.83425105 0.83639763 863.50 -6.03249549e-01 -2.55842268e+00 2.62858073e+00 -1.80235646 0.84045387 863.75 -7.66567102e-01 -2.61852021e+00 2.72841955e+00 -1.85558690 0.90533152 864.00 -8.29983413e-01 -2.43912432e+00 2.57647044e+00 -1.89878513 0.90990403 864.25 -8.29719711e-01 -2.28819934e+00 2.43398665e+00 -1.91865889 0.90632214 864.50 -9.70541928e-01 -2.03489654e+00 2.25449674e+00 -2.01583369 0.84947821 864.75 -1.15112386e+00 -1.84419826e+00 2.17397180e+00 -2.12881052 0.87507550 865.00 -1.13207806e+00 -1.74880593e+00 2.08324817e+00 -2.14530176 0.83997199 865.25 -1.14818167e+00 -1.48495820e+00 1.87707805e+00 -2.22898591 0.82138575 865.50 -1.20294160e+00 -1.35107578e+00 1.80899814e+00 -2.29825894 0.75013514 865.75 -1.14200270e+00 -1.08699148e+00 1.57661683e+00 -2.38086932 0.64318152 866.00 -8.37208168e-01 -9.03090194e-01 1.23145825e+00 -2.31835582 0.53774991 866.25 -6.87040225e-01 -8.02334643e-01 1.05629785e+00 -2.27893728 0.43376422 866.50 -5.05838363e-01 -7.23865765e-01 8.83093480e-01 -2.18071736 0.28470298 866.75 -2.58453337e-01 -8.44767009e-01 8.83419168e-01 -1.86769947 0.22716282 867.00 3.42545988e-01 -8.47901158e-01 9.14480250e-01 -1.18685260 0.15999085 867.25 4.43130417e-01 -7.52465738e-01 8.73252113e-01 -1.03857527 0.14058730 867.50 7.41482561e-01 -1.18126975e+00 1.39470233e+00 -1.01025807 0.34614094 867.75 9.22936453e-01 -1.14798235e+00 1.47298173e+00 -0.89364300 0.41076329 868.00 5.28333933e-01 -1.08049870e+00 1.20275276e+00 -1.11600974 0.23371890 868.25 2.09498166e-01 -1.51701423e+00 1.53141165e+00 -1.43356532 0.26961212 868.50 2.12514368e-01 -1.72872859e+00 1.74174191e+00 -1.44847900 0.39340558 868.75 1.61585612e-01 -1.59142108e+00 1.59960338e+00 -1.46960769 0.40690336 869.00 1.14823023e-01 -1.78909381e+00 1.79277466e+00 -1.50670480 0.53523414 869.25 9.40846739e-02 -2.06476349e+00 2.06690595e+00 -1.52526102 0.61250524 869.50 -1.40830399e-01 -1.95753467e+00 1.96259399e+00 -1.64261533 0.65019823 869.75 -9.71232636e-02 -2.12401649e+00 2.12623587e+00 -1.61649073 0.67205527 870.00 -1.75713767e-02 -1.99010149e+00 1.99017906e+00 -1.57962548 0.59774534 870.25 -5.39903493e-02 -1.95034881e+00 1.95109596e+00 -1.59847167 0.64852788 870.50 1.45458113e-01 -2.18173432e+00 2.18657785e+00 -1.50422398 0.67351936 870.75 7.60838711e-02 -2.17617941e+00 2.17750904e+00 -1.53584843 0.59767574 871.00 1.45865702e-01 -2.13733411e+00 2.14230574e+00 -1.50265543 0.49364792 871.25 4.16667635e-01 -2.01393564e+00 2.05658666e+00 -1.36678249 0.46501143 871.50 3.23104279e-02 -1.77169610e+00 1.77199070e+00 -1.55256134 0.44027910 871.75 -5.15827900e-03 -1.74973747e+00 1.74974508e+00 -1.57374435 0.39671366 872.00 3.94458876e-01 -2.13716537e+00 2.17326336e+00 -1.38827934 0.44220476 872.25 1.44061572e-01 -2.11365980e+00 2.11856354e+00 -1.50274417 0.38065605 872.50 -4.08673678e-01 -2.39295163e+00 2.42759792e+00 -1.73994667 0.38216932 872.75 -3.64555412e-01 -2.33044565e+00 2.35878731e+00 -1.72597037 0.32773760 873.00 1.24042384e-01 -2.38368597e+00 2.38691125e+00 -1.51880517 0.31188422 873.25 -2.73044494e-01 -2.80118754e+00 2.81446352e+00 -1.66796391 0.39713602 873.50 -4.55287336e-01 -2.80250099e+00 2.83924257e+00 -1.73184684 0.43202698 873.75 -2.80548532e-02 -2.56932773e+00 2.56948089e+00 -1.58171503 0.33450849 874.00 -1.57763749e-01 -1.74647632e+00 1.75358745e+00 -1.66088442 0.14383967 874.25 -4.54874457e-01 -1.44802936e+00 1.51779439e+00 -1.87516863 0.09839864 874.50 -5.90731476e-01 -1.70229602e+00 1.80188108e+00 -1.90481427 0.12867015 874.75 -7.77456780e-01 -1.24721566e+00 1.46968906e+00 -2.12821107 0.08360054 875.00 -1.49259183e+00 -1.28491254e+00 1.96947471e+00 -2.43082751 0.12337909 875.25 -1.85654575e+00 -1.28940070e+00 2.26037968e+00 -2.53455672 0.15602324 875.50 -1.25371187e+00 -1.38185191e+00 1.86582640e+00 -2.30761315 0.07703500 875.75 -2.13521463e+00 -1.19143123e+00 2.44512779e+00 -2.63263478 0.17375121 876.00 -2.51462891e+00 -1.06394746e+00 2.73044735e+00 -2.74132973 0.21364168 876.25 -2.71532131e+00 -1.98228899e+00 3.36191009e+00 -2.51098981 0.19832576 876.50 -2.68536497e+00 -2.09137085e+00 3.40367699e+00 -2.47991088 0.14571444 876.75 -3.68259802e+00 -1.78186261e+00 4.09103441e+00 -2.69094005 0.24823190 877.00 -3.78573317e+00 -1.34067728e+00 4.01611644e+00 -2.80123494 0.23447465 877.25 -5.43004619e+00 -5.83037819e-01 5.46125761e+00 -3.03462992 0.40533537 877.50 -6.34714153e+00 -1.38278516e-01 6.34864762e+00 -3.11981015 0.48848726 877.75 -6.87987168e+00 1.03094852e+00 6.95668665e+00 2.99284944 0.67500643 878.00 -6.79894447e+00 1.30537115e+00 6.92312356e+00 2.95190482 0.73281622 878.25 -6.34174669e+00 1.28910216e+00 6.47143999e+00 2.94105253 0.74773417 878.50 -6.37575278e+00 1.58346812e+00 6.56944402e+00 2.89816016 0.75734147 878.75 -6.61797270e+00 2.19188408e+00 6.97150762e+00 2.82176176 0.71389572 879.00 -6.49957140e+00 2.12988466e+00 6.83965183e+00 2.82492410 0.74381231 879.25 -5.75238923e+00 2.22978777e+00 6.16943557e+00 2.77179698 0.79577763 879.50 -5.75974927e+00 1.97995873e+00 6.09056223e+00 2.81048960 0.77889468 879.75 -5.16336254e+00 2.19123534e+00 5.60908415e+00 2.74024603 0.72541301 880.00 -4.73439007e+00 2.15341743e+00 5.20112064e+00 2.71471627 0.72180467 880.25 -4.26492851e+00 2.85328186e+00 5.13135777e+00 2.55196917 0.78721580 880.50 -3.79587235e+00 3.07930668e+00 4.88781920e+00 2.46004456 0.79353084 880.75 -3.25836973e+00 3.03091515e+00 4.45010336e+00 2.39234415 0.86620431 881.00 -3.06486014e+00 2.96821695e+00 4.26657702e+00 2.37221201 0.89499353 881.25 -2.70061023e+00 2.70419778e+00 3.82177723e+00 2.35553072 0.85431201 881.50 -2.37528574e+00 2.53851983e+00 3.47650188e+00 2.32298722 0.85491576 881.75 -2.02276487e+00 2.27516727e+00 3.04433307e+00 2.29753539 0.86223682 882.00 -1.86762455e+00 2.12241940e+00 2.82713381e+00 2.29242342 0.86250202 882.25 -1.39736791e+00 1.70865653e+00 2.20729342e+00 2.25630711 0.81317395 882.50 -1.12103647e+00 1.37885674e+00 1.77706744e+00 2.25342531 0.71273801 882.75 -1.14441969e+00 1.07684847e+00 1.57140034e+00 2.38660522 0.63396460 883.00 -1.32406197e+00 9.54630140e-01 1.63231700e+00 2.51692054 0.71125019 883.25 -1.38265799e+00 1.00934687e+00 1.71187739e+00 2.51101181 0.82938371 883.50 -1.38467287e+00 8.89791240e-01 1.64591841e+00 2.57043691 0.79946380 883.75 -1.30398129e+00 5.69802219e-01 1.42303963e+00 2.72962618 0.69955793 884.00 -1.32439963e+00 5.31546437e-01 1.42708654e+00 2.75992391 0.70839726 884.25 -1.21686015e+00 4.87321128e-01 1.31081292e+00 2.76067753 0.64736295 884.50 -1.15959103e+00 5.28655911e-01 1.27441297e+00 2.71384430 0.63548123 884.75 -1.16966652e+00 4.69480683e-01 1.26036974e+00 2.75989724 0.69619286 885.00 -1.28469880e+00 4.18642087e-01 1.35118918e+00 2.82657598 0.63985381 885.25 -1.49898147e+00 4.39861763e-01 1.56218559e+00 2.85616463 0.72804586 885.50 -1.35062320e+00 3.48166011e-01 1.39477690e+00 2.88930351 0.67948727 885.75 -1.28638372e+00 2.43809486e-01 1.30928459e+00 2.95428348 0.74379048 886.00 -1.32690403e+00 1.63826266e-01 1.33697919e+00 3.01874928 0.72304187 886.25 -1.32001786e+00 2.26711304e-01 1.33934505e+00 2.97150344 0.65757625 886.50 -1.30850678e+00 3.56543978e-02 1.30899245e+00 3.11435124 0.68177200 886.75 -1.27802011e+00 6.39892929e-03 1.27803613e+00 3.13658579 0.60053524 887.00 -1.20689147e+00 1.21231425e-01 1.21296499e+00 3.04147915 0.52413976 887.25 -1.30604376e+00 1.04380110e-01 1.31020820e+00 3.06184133 0.49688801 887.50 -1.36551062e+00 3.27469823e-02 1.36590322e+00 3.11761576 0.51498845 887.75 -1.21654312e+00 7.50446097e-03 1.21656627e+00 3.13542406 0.44613824 888.00 -1.01101074e+00 2.85209725e-01 1.05047004e+00 2.86663439 0.40553235 888.25 -1.22852467e+00 2.73632957e-01 1.25862936e+00 2.92243704 0.53340087 888.50 -1.49744285e+00 2.12074722e-01 1.51238578e+00 3.00090371 0.54664813 888.75 -1.50064001e+00 4.21682332e-02 1.50123236e+00 3.11349988 0.58089174 889.00 -1.38398127e+00 -1.75127788e-01 1.39501753e+00 -3.01572249 0.53158160 889.25 -1.31197618e+00 -2.05618011e-01 1.32799107e+00 -2.98613335 0.52312879 889.50 -1.38976713e+00 -3.02063369e-01 1.42221481e+00 -2.92757314 0.49485043 889.75 -1.48774328e+00 -3.45444056e-01 1.52732172e+00 -2.91344214 0.44696795 890.00 -1.70654739e+00 -2.47495296e-01 1.72440074e+00 -2.99756988 0.48936913 890.25 -1.97825788e+00 -1.09247433e-01 1.98127213e+00 -3.08642463 0.62551697 890.50 -2.13211214e+00 1.47154969e-01 2.13718431e+00 3.07268353 0.60873676 890.75 -2.10261803e+00 8.70221344e-02 2.10441808e+00 3.10022875 0.58833478 891.00 -2.34511642e+00 9.44063482e-03 2.34513543e+00 3.13756702 0.66123665 891.25 -2.58901018e+00 2.29389222e-01 2.59915239e+00 3.05322228 0.65634977 891.50 -2.92041672e+00 7.61661450e-01 3.01810569e+00 2.88647002 0.65820722 891.75 -2.99951741e+00 1.33607319e+00 3.28362547e+00 2.72254615 0.70489054 892.00 -2.90905834e+00 1.56407891e+00 3.30287197e+00 2.64827431 0.74900174 892.25 -2.68283712e+00 1.80187955e+00 3.23177736e+00 2.55016031 0.73572639 892.50 -2.63215261e+00 2.32504180e+00 3.51198615e+00 2.41806796 0.80225834 892.75 -2.53645464e+00 2.51066248e+00 3.56889734e+00 2.36130472 0.81046284 893.00 -2.49747130e+00 2.48066174e+00 3.52009170e+00 2.35957116 0.83119776 893.25 -2.51798454e+00 2.50375435e+00 3.55091988e+00 2.35902820 0.83939524 893.50 -2.51022503e+00 2.45071959e+00 3.50816992e+00 2.36818870 0.85546301 893.75 -2.44720243e+00 2.43088819e+00 3.44935024e+00 2.35953887 0.85056880 894.00 -2.34937061e+00 2.49288072e+00 3.42549216e+00 2.32656610 0.85694504 894.25 -2.31303985e+00 2.62116263e+00 3.49580418e+00 2.29382915 0.86675600 894.50 -2.00737121e+00 2.64364560e+00 3.31939772e+00 2.22023518 0.89836276 894.75 -1.90486547e+00 2.52959445e+00 3.16660079e+00 2.21623507 0.89846248 895.00 -1.79288540e+00 2.38671893e+00 2.98510725e+00 2.21506021 0.86699002 895.25 -1.79221768e+00 2.13757905e+00 2.78949608e+00 2.26853694 0.84349034 895.50 -1.91240927e+00 2.29983930e+00 2.99108175e+00 2.26447554 0.87177329 895.75 -1.79263197e+00 2.45229629e+00 3.03764489e+00 2.20202703 0.87465864 896.00 -1.65576794e+00 2.51536113e+00 3.01141314e+00 2.15295808 0.89753588 896.25 -1.62272950e+00 2.36070070e+00 2.86463939e+00 2.17301112 0.85595059 896.50 -1.60932921e+00 2.35300107e+00 2.85071123e+00 2.17066737 0.86685268 896.75 -1.74635274e+00 2.08447070e+00 2.71933190e+00 2.26816015 0.86593270 897.00 -1.86281154e+00 1.93226824e+00 2.68397604e+00 2.33789476 0.86954763 897.25 -1.85736558e+00 1.91007602e+00 2.66424423e+00 2.34220436 0.88460039 897.50 -1.87323904e+00 1.97289948e+00 2.72054349e+00 2.33028847 0.90554600 897.75 -2.03082658e+00 1.91295458e+00 2.78991968e+00 2.38607366 0.88899458 898.00 -2.23403021e+00 1.97469913e+00 2.98166524e+00 2.41773411 0.92447895 898.25 -2.33149279e+00 2.00269501e+00 3.07353964e+00 2.43191092 0.93447095 898.50 -2.39212566e+00 2.04531088e+00 3.14731025e+00 2.43419249 0.93126852 898.75 -2.85722205e+00 2.25917961e+00 3.64247311e+00 2.47255379 0.93208373 899.00 -3.07313086e+00 2.38349041e+00 3.88910785e+00 2.48191391 0.93471334 899.25 -3.21120831e+00 2.61108101e+00 4.13879244e+00 2.45890588 0.91905936 899.50 -3.30001135e+00 2.80063209e+00 4.32823463e+00 2.43786921 0.92186798 899.75 -3.19943401e+00 3.16067563e+00 4.49736016e+00 2.36228839 0.94306015 900.00 -3.22966047e+00 3.28241752e+00 4.60488562e+00 2.34809325 0.94217133 900.25 -3.26705127e+00 3.23567256e+00 4.59817365e+00 2.36101992 0.91946744 900.50 -3.36918954e+00 3.39105411e+00 4.78023913e+00 2.35296021 0.91620613 900.75 -3.42224232e+00 3.51176062e+00 4.90348908e+00 2.34328516 0.91327951 901.00 -3.36217216e+00 3.57194805e+00 4.90540666e+00 2.32595101 0.91165125 901.25 -3.26398327e+00 3.39687754e+00 4.71087718e+00 2.33624562 0.90128977 901.50 -3.33137243e+00 3.34601785e+00 4.72163931e+00 2.35400121 0.89497324 901.75 -3.84762434e+00 3.48524352e+00 5.19144830e+00 2.40557302 0.91668432 902.00 -4.17287452e+00 3.45588180e+00 5.41811783e+00 2.44990475 0.93150761 902.25 -4.41780721e+00 3.53367718e+00 5.65719851e+00 2.46693019 0.93087342 902.50 -4.61045576e+00 3.59666230e+00 5.84741669e+00 2.47909802 0.91421333 902.75 -5.15670442e+00 3.58155839e+00 6.27846805e+00 2.53453779 0.92078477 903.00 -5.15702329e+00 3.63833580e+00 6.31128962e+00 2.52717771 0.92216208 903.25 -5.99572523e+00 3.97046733e+00 7.19119822e+00 2.55667736 0.92038019 903.50 -6.29234386e+00 4.49313252e+00 7.73187113e+00 2.52149038 0.89193134 903.75 -6.39611231e+00 4.77349108e+00 7.98100682e+00 2.50045648 0.88451903 904.00 -6.14099472e+00 4.60421067e+00 7.67532228e+00 2.49825158 0.87054297 904.25 -6.25436758e+00 4.67906146e+00 7.81093656e+00 2.49929132 0.89242526 904.50 -6.24296331e+00 4.42416259e+00 7.65165378e+00 2.52507564 0.86054681 904.75 -6.27789662e+00 4.11395517e+00 7.50577199e+00 2.56149510 0.83405322 905.00 -6.00263483e+00 3.93392619e+00 7.17686563e+00 2.56145405 0.75970462 905.25 -6.06250095e+00 3.65368625e+00 7.07837135e+00 2.59921238 0.69183546 905.50 -5.96381462e+00 3.06677365e+00 6.70613043e+00 2.66662579 0.71818867 905.75 -6.85411695e+00 2.12838133e+00 7.17697194e+00 2.84050720 0.69770774 906.00 -6.89764902e+00 2.67579586e+00 7.39847589e+00 2.77153571 0.77246300 906.25 -6.41476687e+00 3.18471000e+00 7.16181624e+00 2.68077670 0.75554234 906.50 -6.66609922e+00 2.28717940e+00 7.04755762e+00 2.81107253 0.76705398 906.75 -6.79629399e+00 1.58540449e+00 6.97876202e+00 2.91241618 0.76392564 907.00 -6.81297279e+00 7.02653172e-01 6.84911087e+00 3.03882142 0.72333142 907.25 -6.45837422e+00 3.32743628e-01 6.46694022e+00 3.09011690 0.64385926 907.50 -5.78306127e+00 3.46893732e-01 5.79345605e+00 3.08168000 0.64317679 907.75 -5.26517404e+00 -1.91867840e-01 5.26866881e+00 -3.10516784 0.68137118 908.00 -5.38294751e+00 -4.22706655e-01 5.39951895e+00 -3.06322648 0.74832426 908.25 -5.63857029e+00 -6.92120277e-01 5.68088949e+00 -3.01945614 0.81998791 908.50 -4.58487088e+00 -6.31115941e-01 4.62810418e+00 -3.00480047 0.69603013 908.75 -4.34942376e+00 -6.63992217e-01 4.39981508e+00 -2.99010020 0.63852789 909.00 -3.90520985e+00 -8.84203303e-01 4.00405787e+00 -2.91893053 0.60447562 909.25 -3.46751280e+00 -3.63901371e-01 3.48655549e+00 -3.03702947 0.57185775 909.50 -2.74919166e+00 -6.15575391e-01 2.81726603e+00 -2.92131458 0.43789448 909.75 -2.43406652e+00 -7.53753203e-01 2.54810198e+00 -2.84128964 0.38016759 910.00 -1.93356233e+00 1.88775778e-01 1.94275567e+00 3.04427001 0.13484333 910.25 -1.59377336e+00 -5.96751453e-01 1.70183013e+00 -2.78332461 0.08018590 910.50 -2.15138108e+00 -1.94921708e+00 2.90308246e+00 -2.40545571 0.17799876 910.75 -2.45136231e+00 -2.14738004e+00 3.25889831e+00 -2.42219964 0.24986976 911.00 -2.83263736e+00 -1.89258719e+00 3.40671699e+00 -2.55257346 0.27346462 911.25 -2.83577717e+00 -1.61393435e+00 3.26288465e+00 -2.62417876 0.23663376 911.50 -2.56708015e+00 -1.20473236e+00 2.83571517e+00 -2.70280474 0.26085457 911.75 -2.16477949e+00 -6.77415981e-01 2.26829510e+00 -2.83831965 0.17567813 912.00 -2.06197910e+00 2.33419645e-01 2.07514880e+00 3.02887076 0.18197919 912.25 -2.41155012e+00 -1.97791708e-01 2.41964781e+00 -3.05975733 0.28548593 912.50 -2.55085719e+00 -3.09938844e-01 2.56961758e+00 -3.02068154 0.31446832 912.75 -1.90847197e+00 6.09405772e-02 1.90944468e+00 3.10967189 0.22291425 913.00 -9.84999721e-01 3.43597023e-01 1.04320821e+00 2.80596092 0.09870360 913.25 -1.02916906e+00 -2.55779642e-01 1.06047734e+00 -2.89799776 0.12175747 913.50 -1.07512051e+00 -5.26839740e-01 1.19726531e+00 -2.68595398 0.16229326 913.75 -1.15601397e+00 -6.53403404e-01 1.32789469e+00 -2.62713858 0.16424334 914.00 -8.30616902e-01 -7.96620390e-01 1.15088161e+00 -2.37708362 0.12669636 914.25 -7.03987915e-01 -5.42031797e-01 8.88480418e-01 -2.48544862 0.09278959 914.50 -5.04419001e-01 -2.17141403e-01 5.49171119e-01 -2.73509105 0.03171309 914.75 -3.80534023e-01 -6.81242536e-02 3.86583828e-01 -2.96444644 0.02216273 915.00 -4.77042937e-01 -6.40775110e-02 4.81327218e-01 -3.00806954 0.04124676 915.25 -1.85527323e-01 -1.62397690e-01 2.46563171e-01 -2.42257560 0.01091563 915.50 -1.35388492e-01 -2.50534390e-01 2.84776271e-01 -2.06623833 0.01428521 915.75 -7.92698962e-02 -1.76640982e-01 1.93612379e-01 -1.99262089 0.00580530 916.00 -5.58829491e-01 -3.82178886e-01 6.77016322e-01 -2.54175959 0.06996867 916.25 -4.82580803e-01 -2.49357021e-01 5.43197161e-01 -2.66466218 0.08756344 916.50 -3.72471190e-01 -1.91001603e-01 4.18588581e-01 -2.66776101 0.05229536 916.75 -2.98479663e-01 1.40647356e-01 3.29957251e-01 2.70123909 0.03149747 917.00 -1.50576466e-01 5.27521184e-01 5.48590805e-01 1.84884382 0.10118869 917.25 9.37916540e-02 2.73149082e-01 2.88803212e-01 1.24003865 0.03549175 917.50 3.21950298e-01 -1.80615703e-01 3.69153121e-01 -0.51125301 0.05611246 917.75 1.87958659e-01 -4.82092940e-01 5.17437977e-01 -1.19904394 0.12769616 918.00 -3.36798801e-02 -7.21836832e-01 7.22622132e-01 -1.61742109 0.25416973 918.25 -1.19751155e-01 -1.06814868e+00 1.07484043e+00 -1.68244108 0.51067583 918.50 -8.52668538e-02 -1.18857776e+00 1.19163230e+00 -1.64241220 0.67292031 918.75 -1.01760283e-01 -8.51560357e-01 8.57618911e-01 -1.68973096 0.44482750 919.00 -2.37379358e-01 -6.53422697e-01 6.95205136e-01 -1.91925790 0.37302914 919.25 -2.76655977e-01 -5.90438583e-01 6.52040068e-01 -2.00897721 0.46289018 919.50 -1.96496319e-01 -6.36929245e-01 6.66550573e-01 -1.87003816 0.50488392 919.75 -2.07470776e-01 -6.06264720e-01 6.40781580e-01 -1.90051586 0.43945797 920.00 -3.26691115e-01 -6.93242268e-01 7.66362791e-01 -2.01118138 0.53372932 920.25 -4.98608092e-01 -7.64958912e-01 9.13111256e-01 -2.14844311 0.58472152 920.50 -5.49121861e-01 -6.89102583e-01 8.81134035e-01 -2.24362288 0.63213559 920.75 -6.17408863e-01 -5.76481174e-01 8.44703646e-01 -2.39046202 0.66029239 921.00 -5.95311118e-01 -3.80312516e-01 7.06422633e-01 -2.57309810 0.57297481 921.25 -6.08081661e-01 -9.56236279e-02 6.15554372e-01 -2.98561542 0.52274963 921.50 -4.53495044e-01 2.58819726e-02 4.54233014e-01 3.08458227 0.42014808 921.75 -1.28358675e-01 2.54690092e-02 1.30861071e-01 2.94571618 0.11909602 922.00 9.75733476e-03 1.63832398e-02 1.90687212e-02 1.03364196 0.00304028 922.25 2.84895461e-01 -1.01095526e-01 3.02300726e-01 -0.34099014 0.38745588 922.50 3.74418233e-01 -2.09217274e-01 4.28906611e-01 -0.50955880 0.55068071 922.75 4.51399146e-01 -4.44732219e-01 6.33678101e-01 -0.77795862 0.69849695 923.00 4.86898271e-01 -6.06825117e-01 7.78014556e-01 -0.89461193 0.79243193 923.25 3.61968832e-01 -7.68549376e-01 8.49523148e-01 -1.13063578 0.84077500 923.50 2.31924703e-01 -8.16897486e-01 8.49182295e-01 -1.29416633 0.84839829 923.75 1.20824942e-01 -8.88277607e-01 8.96457347e-01 -1.43560442 0.88627463 924.00 8.75072946e-02 -9.20710893e-01 9.24860030e-01 -1.47603778 0.90390306 924.25 4.48838749e-02 -9.52695507e-01 9.53752217e-01 -1.52371863 0.91311253 924.50 -1.11017571e-02 -9.47285847e-01 9.47350899e-01 -1.58251533 0.88804587 924.75 -3.33072261e-02 -9.42420219e-01 9.43008611e-01 -1.60612385 0.88119952 925.00 -6.76931453e-02 -9.88301294e-01 9.90616884e-01 -1.63918396 0.87946109 925.25 -2.10286202e-01 -1.03176711e+00 1.05297847e+00 -1.77185428 0.86027888 925.50 -3.14068797e-01 -1.02315588e+00 1.07027434e+00 -1.86862692 0.84759750 925.75 -4.53585349e-01 -1.04172293e+00 1.13618939e+00 -1.98145827 0.90012132 926.00 -5.06316937e-01 -9.84640681e-01 1.10719199e+00 -2.04575110 0.89121252 926.25 -5.50091463e-01 -9.16797409e-01 1.06916702e+00 -2.11122627 0.88881349 926.50 -5.98595393e-01 -8.94093587e-01 1.07597388e+00 -2.16075770 0.88222882 926.75 -6.56612762e-01 -8.18912654e-01 1.04964673e+00 -2.24664026 0.89819799 927.00 -7.20983990e-01 -7.80816465e-01 1.06277574e+00 -2.31637505 0.89665156 927.25 -7.76421041e-01 -8.06909840e-01 1.11979155e+00 -2.33694076 0.91697685 927.50 -8.11859967e-01 -7.49730056e-01 1.10508451e+00 -2.39595983 0.90478753 927.75 -8.69676693e-01 -7.84891593e-01 1.17149151e+00 -2.40739274 0.87569780 928.00 -1.05351494e+00 -7.84767808e-01 1.31367965e+00 -2.50136078 0.86583941 928.25 -1.18280250e+00 -7.35142520e-01 1.39264363e+00 -2.58549539 0.86973728 928.50 -1.32451146e+00 -6.39050799e-01 1.47061774e+00 -2.69205871 0.87476668 928.75 -1.43714229e+00 -5.32672297e-01 1.53268319e+00 -2.78664387 0.88827336 929.00 -1.70344236e+00 -3.00788084e-01 1.72979460e+00 -2.96681763 0.88436805 929.25 -1.85481912e+00 -1.92955902e-01 1.86482866e+00 -3.03793601 0.90475887 929.50 -1.91131168e+00 -4.50656360e-03 1.91131700e+00 -3.13923482 0.88140448 929.75 -1.97540012e+00 1.65976070e-01 1.98236063e+00 3.05776805 0.86077126 930.00 -1.85590450e+00 4.29344012e-01 1.90491936e+00 2.91425244 0.84660662 930.25 -1.72915140e+00 5.61547817e-01 1.81804854e+00 2.82758380 0.85934728 930.50 -1.63110697e+00 8.62706089e-01 1.84520236e+00 2.65508671 0.85010330 930.75 -1.66698645e+00 9.62221831e-01 1.92476354e+00 2.61808983 0.83829687 931.00 -1.81364060e+00 1.11494608e+00 2.12894269e+00 2.59039389 0.87167519 931.25 -1.74330910e+00 1.22304214e+00 2.12954424e+00 2.52981809 0.86888834 931.50 -1.78521350e+00 1.76413247e+00 2.50981087e+00 2.36213383 0.87702789 931.75 -1.83365956e+00 2.14524587e+00 2.82212459e+00 2.27804442 0.89691617 932.00 -1.58817138e+00 2.82920014e+00 3.24448174e+00 2.08231173 0.89640198 932.25 -1.29866729e+00 3.11602579e+00 3.37581894e+00 1.96567582 0.89026953 932.50 -4.41785637e-01 3.45666689e+00 3.48478415e+00 1.69791401 0.86175142 932.75 1.17493207e-01 3.61644893e+00 3.61835702e+00 1.53831919 0.87327045 933.00 8.64706639e-01 3.30391050e+00 3.41519285e+00 1.31481582 0.85526262 933.25 9.96098891e-01 3.10610748e+00 3.26191918e+00 1.26046723 0.84281346 933.50 1.31602177e+00 2.77567679e+00 3.07185529e+00 1.12806097 0.78833998 933.75 1.45889484e+00 2.43205169e+00 2.83606233e+00 1.03047847 0.73950639 934.00 1.59721371e+00 2.18186421e+00 2.70400130e+00 0.93888850 0.76867877 934.25 1.62592184e+00 2.19352023e+00 2.73041258e+00 0.93292614 0.75045649 934.50 1.83589741e+00 2.20949209e+00 2.87269466e+00 0.87748769 0.77595121 934.75 1.98677323e+00 2.18519706e+00 2.95336318e+00 0.83292353 0.78353401 935.00 2.30201367e+00 2.27623218e+00 3.23736002e+00 0.77976692 0.75116250 935.25 2.77960877e+00 1.74180423e+00 3.28026019e+00 0.55977524 0.74843669 935.50 3.10600952e+00 1.17226633e+00 3.31986498e+00 0.36088956 0.86107239 935.75 3.13472388e+00 1.24923295e+00 3.37447429e+00 0.37922513 0.88458035 936.00 3.32266643e+00 9.66648483e-01 3.46042216e+00 0.28311094 0.90929383 936.25 3.50425150e+00 7.77130149e-01 3.58938850e+00 0.21823587 0.91784578 936.50 3.66341551e+00 6.65951700e-01 3.72345336e+00 0.17982077 0.93878807 936.75 3.67365056e+00 4.79249097e-01 3.70477910e+00 0.12972322 0.92132709 937.00 3.82771044e+00 4.92754801e-01 3.85929716e+00 0.12802941 0.92165970 937.25 3.93817891e+00 5.67486003e-01 3.97885580e+00 0.14311345 0.92513720 937.50 4.21998099e+00 4.03616334e-01 4.23923881e+00 0.09535406 0.91236046 937.75 4.44796987e+00 2.54144595e-01 4.45522451e+00 0.05707516 0.87364827 938.00 4.95187532e+00 -2.16216678e-01 4.95659347e+00 -0.04363588 0.86114799 938.25 5.54132232e+00 -6.63878264e-01 5.58094861e+00 -0.11923672 0.84615425 938.50 5.66615163e+00 -1.14297246e+00 5.78028203e+00 -0.19904824 0.81356025 938.75 6.08421566e+00 -1.79431899e+00 6.34328470e+00 -0.28678402 0.76935800 939.00 6.35790352e+00 -2.33890113e+00 6.77446645e+00 -0.35250776 0.70210954 939.25 4.96875524e+00 -4.00763313e+00 6.38354541e+00 -0.67873230 0.66599825 939.50 3.96960915e+00 -4.63525312e+00 6.10273449e+00 -0.86260114 0.67928892 939.75 2.51350418e+00 -4.82317342e+00 5.43881468e+00 -1.09038734 0.61493451 940.00 1.83397103e+00 -4.67825389e+00 5.02488897e+00 -1.19718777 0.59104414 940.25 1.73304251e+00 -4.05558278e+00 4.41035010e+00 -1.16695999 0.52692571 940.50 9.34581993e-01 -3.68172434e+00 3.79849149e+00 -1.32220349 0.48789682 940.75 7.44756780e-01 -3.01202054e+00 3.10272951e+00 -1.32839671 0.43964957 941.00 8.75124351e-01 -2.83055598e+00 2.96275037e+00 -1.27094763 0.32389890 941.25 9.59130737e-01 -2.19058477e+00 2.39135807e+00 -1.15809859 0.26227860 941.50 8.40718125e-01 -1.90336318e+00 2.08076870e+00 -1.15486494 0.28273902 941.75 1.34751382e+00 -1.03304676e+00 1.69793378e+00 -0.65406068 0.25690396 942.00 1.86559066e+00 -3.91886228e-01 1.90630620e+00 -0.20704979 0.31203139 942.25 2.52897873e+00 7.94125751e-03 2.52899120e+00 0.00314009 0.36969105 942.50 2.93300942e+00 -1.91568844e-01 2.93925890e+00 -0.06522213 0.42266328 942.75 2.81658420e+00 -4.22308604e-01 2.84806797e+00 -0.14882778 0.41276301 943.00 3.17951978e+00 -4.96369400e-01 3.21803180e+00 -0.15486455 0.46154441 943.25 3.36327179e+00 -8.65034685e-01 3.47273410e+00 -0.25174390 0.52138755 943.50 3.46330860e+00 -1.07883452e+00 3.62744957e+00 -0.30197723 0.61166094 943.75 3.54035746e+00 -6.27507939e-01 3.59553851e+00 -0.17542238 0.66135460 944.00 3.22381550e+00 -5.85914623e-01 3.27662667e+00 -0.17978334 0.61733022 944.25 3.22824825e+00 -7.62321655e-01 3.31703498e+00 -0.23189294 0.64948086 944.50 3.06950211e+00 -8.48421436e-01 3.18459764e+00 -0.26967066 0.64129420 944.75 2.94019689e+00 -6.58966444e-01 3.01313699e+00 -0.22047977 0.63314173 945.00 2.58920365e+00 -8.54988422e-01 2.72671611e+00 -0.31893953 0.59515123 945.25 2.07284906e+00 -1.13843641e+00 2.36489761e+00 -0.50223907 0.60106007 945.50 1.85306394e+00 -9.29522986e-01 2.07312782e+00 -0.46493805 0.55445305 945.75 1.77970936e+00 -6.63289811e-01 1.89929428e+00 -0.35674883 0.60215548 946.00 1.48023177e+00 -8.84728838e-01 1.72447999e+00 -0.53872377 0.54997886 946.25 7.70553511e-01 -1.08794769e+00 1.33318524e+00 -0.95454597 0.51380721 946.50 6.71472000e-01 -8.28882667e-01 1.06673386e+00 -0.88993138 0.50712106 946.75 4.92500191e-01 -5.31691069e-01 7.24742597e-01 -0.82364470 0.54076191 947.00 4.62301187e-01 -4.51589681e-01 6.46262816e-01 -0.77367793 0.45150582 947.25 4.34574833e-01 -3.95880623e-01 5.87857766e-01 -0.73883788 0.41163319 947.50 4.85526824e-01 -3.87510521e-01 6.21209064e-01 -0.67359588 0.48562368 947.75 4.42417561e-01 -4.26378129e-01 6.14436007e-01 -0.76693858 0.53243728 948.00 2.11559044e-01 -3.54763578e-01 4.13054991e-01 -1.03307374 0.35552473 948.25 7.33322103e-02 -2.08033177e-01 2.20579727e-01 -1.23189387 0.17228647 948.50 2.23259807e-02 -1.23496130e-01 1.25497982e-01 -1.39194522 0.05546627 948.75 3.20808223e-02 4.56981383e-02 5.58345682e-02 0.95871865 0.01311147 949.00 4.64348375e-02 1.19365786e-01 1.28079604e-01 1.19979727 0.05692525 949.25 2.96483771e-02 1.95892394e-01 1.98123336e-01 1.42058603 0.15014288 949.50 -4.05566100e-02 2.73538772e-01 2.76529019e-01 1.71799040 0.24925999 949.75 -5.30189367e-02 3.39383674e-01 3.43500053e-01 1.72576499 0.31622336 950.00 8.89601818e-02 4.52397212e-01 4.61060898e-01 1.37663192 0.37132045 950.25 1.89858138e-01 5.04984744e-01 5.39495788e-01 1.21117721 0.38746593 950.50 1.42664659e-01 3.74719552e-01 4.00958785e-01 1.20701698 0.27420395 950.75 2.48516625e-01 2.81486127e-01 3.75492946e-01 0.84752440 0.27436553 951.00 3.87750321e-01 4.12961591e-01 5.66469405e-01 0.81687383 0.41050131 951.25 3.76159667e-01 4.07915777e-01 5.54879605e-01 0.82587738 0.35352500 951.50 2.58164335e-01 2.77574678e-01 3.79073246e-01 0.82161329 0.22396003 951.75 1.42183251e-01 1.75704114e-01 2.26026575e-01 0.89045877 0.12499489 952.00 2.83965773e-02 1.34418186e-01 1.37384913e-01 1.36260199 0.04265028 952.25 -1.58671122e-01 1.39982125e-01 2.11592817e-01 2.41869057 0.07998031 952.50 -3.37071335e-01 4.78039603e-01 5.84926445e-01 2.18494475 0.40174268 952.75 -3.87207548e-01 6.41039464e-01 7.48906723e-01 2.11417434 0.54110643 953.00 -3.23510558e-01 1.04541401e+00 1.09432606e+00 1.87090642 0.61060471 953.25 -1.44860693e-01 1.26884795e+00 1.27709034e+00 1.68447125 0.62321320 953.50 2.21893715e-01 1.43205021e+00 1.44913927e+00 1.41707054 0.71999912 953.75 4.21771653e-01 1.33348720e+00 1.39859910e+00 1.26446035 0.72032567 954.00 6.87823745e-01 1.23769321e+00 1.41597527e+00 1.06356422 0.71196384 954.25 6.57693268e-01 1.20858025e+00 1.37594573e+00 1.07242728 0.73545317 954.50 8.43004223e-01 1.14932904e+00 1.42534675e+00 0.93795531 0.73936203 954.75 8.91055975e-01 1.04058697e+00 1.36996423e+00 0.86265539 0.70602937 955.00 7.28350371e-01 1.00967045e+00 1.24496132e+00 0.94586873 0.68454837 955.25 6.89293262e-01 9.45235226e-01 1.16986958e+00 0.94072150 0.62835582 955.50 9.20139513e-01 6.61936730e-01 1.13349767e+00 0.62361945 0.56727366 955.75 8.92708830e-01 5.98615339e-01 1.07483458e+00 0.59069354 0.52765786 956.00 7.58861817e-01 4.33616572e-01 8.74010634e-01 0.51912749 0.41329682 956.25 9.27204818e-01 3.95264586e-01 1.00793991e+00 0.40296866 0.51132987 956.50 1.07803728e+00 4.96868827e-01 1.18703118e+00 0.43188241 0.58773864 956.75 1.18133571e+00 4.39238091e-01 1.26035081e+00 0.35597524 0.58629844 957.00 1.34066292e+00 2.86577616e-02 1.34096918e+00 0.02137256 0.73959561 957.25 1.26118057e+00 -1.33352480e-01 1.26821107e+00 -0.10534480 0.69293875 957.50 1.14416337e+00 -2.72267795e-01 1.17611206e+00 -0.23361741 0.65561109 957.75 1.03329369e+00 -3.63544789e-01 1.09538151e+00 -0.33830510 0.60385504 958.00 9.25827986e-01 -5.70843137e-01 1.08766693e+00 -0.55251852 0.60700905 958.25 6.58190913e-01 -5.55197412e-01 8.61080394e-01 -0.70072023 0.47304032 958.50 4.62915498e-01 -5.76157287e-01 7.39085907e-01 -0.89395323 0.45020627 958.75 4.39552172e-01 -6.51031627e-01 7.85524214e-01 -0.97693500 0.49109748 959.00 3.05508062e-01 -5.89657307e-01 6.64101585e-01 -1.09276495 0.48454562 959.25 1.83006010e-01 -5.11037963e-01 5.42817649e-01 -1.22691802 0.49946677 959.50 1.29646658e-01 -4.74507606e-01 4.91900116e-01 -1.30408241 0.44921580 959.75 -7.67346237e-02 -3.62318177e-01 3.70354781e-01 -1.77950033 0.31454592 960.00 -6.79366288e-02 -2.11842136e-01 2.22469046e-01 -1.88112922 0.18718009 960.25 -2.73729279e-02 -9.34552023e-02 9.73814768e-02 -1.85572570 0.04992033 960.50 -2.39865791e-02 -1.43493291e-03 2.40294613e-02 -3.08184154 0.00317040 960.75 5.76545382e-02 6.75573549e-02 8.88146496e-02 0.86432235 0.03666996 961.00 1.01415959e-01 8.91770209e-02 1.35047169e-01 0.72127116 0.09146782 961.25 1.90389878e-02 4.85961851e-02 5.21926457e-02 1.19739664 0.00812500 961.50 2.87108261e-02 1.01377516e-01 1.05364663e-01 1.29481622 0.02779760 961.75 7.29580856e-02 2.38989567e-01 2.49877761e-01 1.27450505 0.11130315 962.00 9.84645843e-02 2.83319941e-01 2.99942434e-01 1.23631607 0.19348873 962.25 1.48820084e-01 3.41353243e-01 3.72383477e-01 1.15967004 0.24444961 962.50 1.68729184e-01 4.33544212e-01 4.65220508e-01 1.19964729 0.30353783 962.75 2.28969173e-01 4.67089843e-01 5.20192084e-01 1.11501642 0.37726739 963.00 2.56371886e-01 4.90907856e-01 5.53820429e-01 1.08951516 0.44792058 963.25 2.53181413e-01 4.97673295e-01 5.58372221e-01 1.10018901 0.57761081 963.50 3.08176630e-01 4.49207765e-01 5.44757241e-01 0.96949783 0.54991988 963.75 3.62364805e-01 4.09328029e-01 5.46678779e-01 0.84618060 0.57582570 964.00 3.46585110e-01 3.63224155e-01 5.02048827e-01 0.80883544 0.53316955 964.25 3.35937120e-01 2.54187238e-01 4.21265831e-01 0.64774433 0.46773754 964.50 2.78731861e-01 3.05982694e-01 4.13904409e-01 0.83196983 0.45207135 964.75 2.47138459e-01 3.99202363e-01 4.69510325e-01 1.01646495 0.52165934 965.00 1.61727748e-01 3.39698209e-01 3.76232292e-01 1.12645704 0.34414277 965.25 6.32001870e-02 2.91456488e-01 2.98230025e-01 1.35725963 0.23914208 965.50 -4.15814353e-02 3.46545998e-01 3.49031725e-01 1.69021363 0.30740510 965.75 -5.42204747e-02 3.91388395e-01 3.95126227e-01 1.70845385 0.36306173 966.00 -5.27545213e-02 3.64036289e-01 3.67838904e-01 1.71471004 0.25547381 966.25 -4.99724061e-02 4.24834791e-01 4.27763768e-01 1.68788613 0.26968311 966.50 -6.00345925e-02 4.50124582e-01 4.54110440e-01 1.70338711 0.31827784 966.75 1.75749664e-02 5.02356501e-01 5.02663838e-01 1.53582554 0.25608542 967.00 1.55032539e-02 4.01920143e-01 4.02219035e-01 1.53224247 0.21378288 967.25 -6.65375249e-02 3.66878998e-01 3.72863838e-01 1.75020719 0.25973285 967.50 -1.00330313e-01 4.03843480e-01 4.16119848e-01 1.81430491 0.37651786 967.75 -7.30505966e-02 3.56107349e-01 3.63522810e-01 1.77312586 0.33775688 968.00 -7.61963702e-02 3.49079544e-01 3.57298775e-01 1.78570350 0.33377370 968.25 -8.72420675e-02 4.75838119e-01 4.83769670e-01 1.75212643 0.43977773 968.50 -9.96712436e-02 5.06816806e-01 5.16524570e-01 1.76497953 0.40691301 968.75 -7.28526638e-02 4.76189077e-01 4.81729746e-01 1.72261021 0.46511775 969.00 -8.19482636e-02 5.29546447e-01 5.35849753e-01 1.72433024 0.49216670 969.25 -1.46180916e-01 4.40485295e-01 4.64107914e-01 1.89122329 0.31308710 969.50 8.72395908e-03 4.46508355e-01 4.46593572e-01 1.55126064 0.27382778 969.75 1.96599566e-01 4.38045152e-01 4.80140547e-01 1.14893146 0.33286091 970.00 1.28902842e-01 5.15891335e-01 5.31751645e-01 1.32594536 0.33233466 970.25 1.22875854e-01 4.17721829e-01 4.35419340e-01 1.28470855 0.29463070 970.50 3.19231034e-01 3.25995802e-01 4.56269346e-01 0.79588210 0.23395880 970.75 3.95114811e-01 2.98151205e-01 4.94984702e-01 0.64643469 0.34468458 971.00 2.81021075e-01 2.35855597e-01 3.66879690e-01 0.69823801 0.25962786 971.25 2.68189884e-01 1.84533999e-01 3.25543562e-01 0.60267578 0.20093324 971.50 2.82684914e-01 1.28305600e-01 3.10440152e-01 0.42607752 0.28814603 971.75 2.38885417e-01 9.86160606e-02 2.58440264e-01 0.39150681 0.25036789 972.00 1.66493164e-01 4.76586381e-02 1.73180020e-01 0.27879471 0.09520231 972.25 1.75336700e-01 -1.61742579e-02 1.76081132e-01 -0.09198652 0.08949365 972.50 2.28210624e-01 -5.84633897e-02 2.35580256e-01 -0.25078823 0.18130314 972.75 2.33718903e-01 -4.15314240e-02 2.37380254e-01 -0.17586247 0.25393218 973.00 1.60183774e-01 -9.72687872e-02 1.87403464e-01 -0.54572052 0.22539539 973.25 1.21409330e-01 -1.26444104e-01 1.75295000e-01 -0.80570888 0.22511464 973.50 2.83749080e-01 -1.31539729e-01 3.12755880e-01 -0.43408755 0.47432265 973.75 2.82510037e-01 -1.76578101e-01 3.33154238e-01 -0.55862306 0.54571437 974.00 2.61138309e-01 -2.31737020e-01 3.49135021e-01 -0.72581618 0.54269075 974.25 2.56888774e-01 -2.83139596e-01 3.82308610e-01 -0.83397001 0.57347384 974.50 2.00007583e-01 -3.51030092e-01 4.04011336e-01 -1.05289890 0.56989020 974.75 1.33259068e-01 -3.67147857e-01 3.90583574e-01 -1.22262503 0.49477519 975.00 -3.29080116e-02 -4.41006907e-01 4.42233004e-01 -1.64527846 0.60008426 975.25 -6.74437058e-02 -4.23801401e-01 4.29134339e-01 -1.72861283 0.59835080 975.50 -1.72863014e-01 -2.99556939e-01 3.45855434e-01 -2.09417909 0.39116573 975.75 -2.08664983e-01 -2.76181736e-01 3.46146539e-01 -2.21783047 0.34728074 976.00 -1.42446684e-01 -1.55904988e-01 2.11181020e-01 -2.31111619 0.23208880 976.25 -1.04442471e-01 -6.26663870e-02 1.21800270e-01 -2.60116679 0.10062361 976.50 -3.41809484e-02 5.57235398e-02 6.53716309e-02 2.12101223 0.03707145 976.75 -1.75331318e-02 3.85155017e-02 4.23184898e-02 1.99798498 0.01468001 977.00 1.71725160e-02 1.63190912e-03 1.72498821e-02 0.09474576 0.00225944 977.25 6.94649776e-02 -9.70018228e-02 1.19309416e-01 -0.94933308 0.09161289 977.50 6.22405883e-02 -1.62826196e-01 1.74316554e-01 -1.20568322 0.15740704 977.75 5.63072462e-02 -1.44152096e-01 1.54758950e-01 -1.19841092 0.10832905 978.00 1.59820797e-01 -1.64479313e-01 2.29338465e-01 -0.79976200 0.25370791 978.25 1.16172373e-01 -1.89571095e-01 2.22335828e-01 -1.02100589 0.22403945 978.50 6.02913752e-02 -2.73506908e-01 2.80073345e-01 -1.35382807 0.40364374 978.75 3.77024268e-02 -3.28087162e-01 3.30246361e-01 -1.45638232 0.45057916 979.00 -1.31150516e-02 -3.43307118e-01 3.43557538e-01 -1.60897986 0.45333604 979.25 -6.03597012e-02 -2.99399496e-01 3.05423234e-01 -1.76973232 0.42492237 979.50 -5.33023132e-02 -2.90021500e-01 2.94878970e-01 -1.75255542 0.47958941 979.75 -9.75811746e-02 -2.65999637e-01 2.83333536e-01 -1.92240009 0.44954326 980.00 -1.34827451e-01 -2.00313287e-01 2.41461911e-01 -2.16322780 0.38971198 980.25 -9.06653775e-02 -1.93871716e-01 2.14024422e-01 -2.00823604 0.33460622 980.50 -2.90277880e-02 -1.67599886e-01 1.70095074e-01 -1.74229198 0.26832470 980.75 3.80699139e-02 -1.68288867e-01 1.72541187e-01 -1.34832320 0.25410176 981.00 7.63951978e-02 -2.00744017e-01 2.14789168e-01 -1.20715983 0.38638994 981.25 1.19542376e-01 -2.77062607e-01 3.01751666e-01 -1.16346388 0.50698979 981.50 1.49577485e-01 -2.80794100e-01 3.18148945e-01 -1.08133646 0.53349890 981.75 9.96924868e-02 -2.85251447e-01 3.02170449e-01 -1.23457605 0.38878493 982.00 9.85926513e-02 -2.96350117e-01 3.12320193e-01 -1.24962509 0.44665397 982.25 1.66751569e-01 -3.54443248e-01 3.91709206e-01 -1.13105828 0.57665386 982.50 1.86923495e-01 -3.79154764e-01 4.22727723e-01 -1.11276397 0.61552680 982.75 1.21497866e-01 -4.23979110e-01 4.41044235e-01 -1.29170970 0.60867743 983.00 1.51594905e-01 -4.88730667e-01 5.11701749e-01 -1.27002565 0.67482417 983.25 2.41474288e-01 -4.96750831e-01 5.52332527e-01 -1.11832439 0.69847399 983.50 2.51601966e-01 -5.16071528e-01 5.74137067e-01 -1.11717187 0.65711208 983.75 1.06888136e-01 -6.46064468e-01 6.54846830e-01 -1.40683653 0.66600713 984.00 1.36508764e-01 -6.97055140e-01 7.10296073e-01 -1.37740742 0.67431457 984.25 1.38239783e-01 -7.72588339e-01 7.84858573e-01 -1.39373931 0.53883734 984.50 7.45440744e-03 -7.33433944e-01 7.33471826e-01 -1.56063297 0.46140950 984.75 -1.56083955e-01 -6.80968048e-01 6.98626999e-01 -1.79611326 0.41892688 985.00 -2.78223719e-01 -7.54493469e-01 8.04157219e-01 -1.92408128 0.44830449 985.25 -5.66909469e-01 -6.25705709e-01 8.44330492e-01 -2.30693411 0.49090354 985.50 -6.07058836e-01 -5.64363973e-01 8.28870994e-01 -2.39262538 0.46265291 985.75 -6.23403795e-01 -4.30983483e-01 7.57877995e-01 -2.53670299 0.36625853 986.00 -6.86463455e-01 -3.05294322e-01 7.51290023e-01 -2.72312573 0.41186856 986.25 -7.32866617e-01 -1.55694354e-01 7.49222404e-01 -2.93225923 0.47333115 986.50 -7.80019114e-01 -1.23656409e-01 7.89759916e-01 -2.98437105 0.48109986 986.75 -8.17738565e-01 -1.91232416e-01 8.39801285e-01 -2.91186586 0.61470253 987.00 -7.49916770e-01 -1.72830654e-01 7.69574946e-01 -2.91508130 0.62886962 987.25 -6.72694133e-01 -3.32003995e-02 6.73512927e-01 -3.09227829 0.58058743 987.50 -6.86690884e-01 -5.56121144e-02 6.88939096e-01 -3.06078335 0.56659448 987.75 -7.82759121e-01 -8.34091095e-02 7.87190524e-01 -3.03543541 0.61182113 988.00 -8.19905117e-01 7.86407322e-03 8.19942830e-01 3.13200150 0.64077996 988.25 -8.22460491e-01 1.71964393e-01 8.40245804e-01 2.93547669 0.72076754 988.50 -9.17705942e-01 2.06725401e-01 9.40701646e-01 2.92002768 0.73269391 988.75 -8.97319097e-01 1.56088395e-01 9.10793692e-01 2.96936625 0.66845184 989.00 -8.75406736e-01 2.43303549e-01 9.08588780e-01 2.87050263 0.62970149 989.25 -7.85726921e-01 3.94589422e-01 8.79242632e-01 2.67618928 0.72820467 989.50 -8.49570945e-01 4.20183324e-01 9.47799987e-01 2.68228805 0.70984906 989.75 -7.97971934e-01 4.04825355e-01 8.94786441e-01 2.67210797 0.65469233 990.00 -7.42163373e-01 4.09688945e-01 8.47733156e-01 2.63719999 0.65584590 990.25 -7.59983918e-01 4.94131401e-01 9.06499530e-01 2.56508623 0.69243969 990.50 -7.55345030e-01 5.76214580e-01 9.50036503e-01 2.48991846 0.61251176 990.75 -7.62508749e-01 7.16762004e-01 1.04650244e+00 2.38710984 0.65465376 991.00 -7.63830935e-01 8.03099006e-01 1.10833466e+00 2.33113922 0.70129458 991.25 -7.43139238e-01 8.19739814e-01 1.10644896e+00 2.30722120 0.63558998 991.50 -7.25997428e-01 1.00396494e+00 1.23895838e+00 2.19687787 0.64495518 991.75 -4.99692211e-01 1.08061242e+00 1.19055261e+00 2.00392709 0.71912319 992.00 -5.16479727e-01 9.73579572e-01 1.10209278e+00 2.05854178 0.75166822 992.25 -4.50720719e-01 1.01072802e+00 1.10667081e+00 1.99026608 0.75812984 992.50 -1.78834638e-01 1.16993841e+00 1.18352765e+00 1.72248037 0.78595148 992.75 -5.75677341e-02 1.21585730e+00 1.21721937e+00 1.61810844 0.84371465 993.00 -4.75588550e-03 1.21674732e+00 1.21675661e+00 1.57470499 0.84484227 993.25 6.63152526e-02 1.14717456e+00 1.14908972e+00 1.51305313 0.84061804 993.50 2.13164745e-01 1.14998045e+00 1.16957011e+00 1.38751282 0.85273038 993.75 2.99483897e-01 1.08305035e+00 1.12369420e+00 1.30101855 0.87783509 994.00 3.97942754e-01 9.11867598e-01 9.94917560e-01 1.15930610 0.84086962 994.25 3.98143659e-01 8.56962881e-01 9.44935846e-01 1.13586883 0.82619619 994.50 3.56513862e-01 7.63610816e-01 8.42735790e-01 1.13399481 0.82845200 994.75 3.56839329e-01 7.43821948e-01 8.24988120e-01 1.12348967 0.82381156 995.00 3.46625129e-01 6.28997899e-01 7.18183359e-01 1.06712802 0.77784540 995.25 3.03950610e-01 6.07999242e-01 6.79741901e-01 1.10721321 0.78349568 995.50 2.24586560e-01 4.96897650e-01 5.45294781e-01 1.14629912 0.62112379 995.75 2.39936165e-01 4.89501187e-01 5.45142894e-01 1.11504793 0.56418675 996.00 2.80772675e-01 5.85168500e-01 6.49041962e-01 1.12342665 0.59662421 996.25 2.08961615e-01 6.56915130e-01 6.89349291e-01 1.26282211 0.61159425 996.50 2.06473785e-01 6.58184926e-01 6.89810714e-01 1.26681697 0.59299058 996.75 2.69395046e-01 6.49209841e-01 7.02884847e-01 1.17746169 0.54917251 997.00 3.85388652e-01 6.16266523e-01 7.26848568e-01 1.01193792 0.48004170 997.25 4.51206949e-01 6.33715508e-01 7.77935123e-01 0.95206041 0.47878834 997.50 3.83252512e-01 5.85988454e-01 7.00189229e-01 0.99159509 0.47019657 997.75 6.14575445e-01 6.79985375e-01 9.16560466e-01 0.83588197 0.57952358 998.00 7.96871457e-01 5.53262603e-01 9.70104957e-01 0.60688576 0.66028729 998.25 7.23286045e-01 5.26434677e-01 8.94581562e-01 0.62916555 0.64188704 998.50 8.84195881e-01 6.03305320e-01 1.07041098e+00 0.59876199 0.67140131 998.75 9.73234534e-01 4.95625915e-01 1.09216780e+00 0.47102528 0.67807535 999.00 1.04987446e+00 4.37138478e-01 1.13724511e+00 0.39454014 0.76813743 999.25 1.07051680e+00 3.66183929e-01 1.13141366e+00 0.32958636 0.77734807 999.50 1.20723740e+00 1.36845456e-01 1.21496865e+00 0.11287243 0.77517107 999.75 1.18524629e+00 3.22828050e-03 1.18525069e+00 0.00272371 0.71421826 1000.00 1.18274635e+00 0.00000000e+00 1.18274635e+00 0.00000000 0.72699050