========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : Z Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0041 Injection acquisition : SIG0042 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -2.56422325e-02 0.00000000e+00 2.56422325e-02 3.14159265 0.12123908 0.25 -2.46090784e-02 8.08975459e-03 2.59046496e-02 2.82399036 0.13170435 0.50 -1.19616337e-02 5.15786890e-03 1.30262924e-02 2.73448142 0.09804122 0.75 -1.51348420e-02 3.44750531e-03 1.55225234e-02 2.91762803 0.13133320 1.00 -1.17446476e-02 -2.34218125e-03 1.19759158e-02 -2.94474964 0.06451636 1.25 -9.44726156e-03 1.00390680e-03 9.50045156e-03 3.03572563 0.04139696 1.50 -8.15735713e-03 5.47817421e-03 9.82613190e-03 2.55020836 0.03993025 1.75 -9.42513701e-03 1.87212092e-03 9.60926868e-03 2.94551414 0.03833437 2.00 -1.12085720e-02 -3.47359731e-04 1.12139531e-02 -3.11061203 0.04115703 2.25 -1.27881936e-02 -1.04821319e-03 1.28310813e-02 -3.05980823 0.05791230 2.50 -1.23547064e-02 -1.58091766e-03 1.24554434e-02 -3.01432352 0.04466623 2.75 -1.09342131e-02 -3.72287567e-03 1.15506198e-02 -2.81342437 0.04579175 3.00 -8.11405881e-03 -8.51637821e-03 1.17629354e-02 -2.33200746 0.04092226 3.25 -1.33049726e-02 -2.37951468e-03 1.35160788e-02 -2.96461965 0.06037390 3.50 -1.54477669e-02 2.23907702e-03 1.56091950e-02 2.99765007 0.07386377 3.75 -1.97564959e-02 -1.30468575e-03 1.97995286e-02 -3.07565008 0.11358078 4.00 -1.89638194e-02 -1.41128347e-03 1.90162606e-02 -3.06730979 0.09266215 4.25 -9.57424234e-03 -9.81646320e-03 1.37123691e-02 -2.34370354 0.04825546 4.50 -9.23232502e-03 -1.37912120e-02 1.65961849e-02 -2.16071327 0.06321179 4.75 -1.83759336e-02 -8.18656803e-03 2.01170284e-02 -2.72248316 0.09316751 5.00 -1.69104745e-02 -4.89143080e-03 1.76036997e-02 -2.86002304 0.07098316 5.25 -2.01494247e-02 -4.36461895e-03 2.06167217e-02 -2.92827567 0.07883269 5.50 -1.96091166e-02 -7.44620849e-03 2.09753063e-02 -2.77867987 0.07256007 5.75 -1.89589960e-02 -8.87879969e-03 2.09350571e-02 -2.70361204 0.08997668 6.00 -1.83129465e-02 -7.55696562e-03 1.98108995e-02 -2.75022291 0.09123991 6.25 -1.02282656e-02 -8.48229517e-03 1.32878421e-02 -2.44923975 0.03412409 6.50 -1.05035607e-02 -1.14367118e-02 1.55281410e-02 -2.31368868 0.04165543 6.75 -3.32973961e-03 -1.40092130e-02 1.43994866e-02 -1.80414853 0.03263405 7.00 -4.76644550e-03 -1.18692519e-02 1.27905490e-02 -1.95266340 0.02709231 7.25 -1.28034451e-02 -5.45426956e-03 1.39167978e-02 -2.73887517 0.03096021 7.50 -1.16876763e-02 -4.30807598e-03 1.24563758e-02 -2.78844483 0.02647915 7.75 -2.87475848e-03 -7.26378743e-03 7.81196801e-03 -1.94764719 0.00728762 8.00 -7.57763022e-03 -8.08794525e-03 1.10831105e-02 -2.32363044 0.01662854 8.25 -2.08205795e-02 -1.12099874e-02 2.36465716e-02 -2.64769201 0.07875520 8.50 -1.52004683e-02 -1.30747662e-02 2.00500311e-02 -2.43123227 0.06078052 8.75 -1.00426764e-02 -9.59642144e-03 1.38905239e-02 -2.37891336 0.02526211 9.00 -1.59266010e-02 -1.15920257e-02 1.96985197e-02 -2.51242509 0.05127907 9.25 -1.92955541e-02 -1.08582510e-02 2.21409129e-02 -2.62902598 0.05554193 9.50 -1.71016541e-02 -1.26404600e-02 2.12661186e-02 -2.50508039 0.05500629 9.75 -1.91341115e-02 -9.40824466e-03 2.13220377e-02 -2.68460698 0.04391729 10.00 -1.75058551e-02 -1.21599799e-02 2.13147853e-02 -2.53448414 0.04931718 10.25 -2.48032179e-02 -2.82203803e-02 3.75711256e-02 -2.29183742 0.13408311 10.50 -1.80892579e-02 -2.42959081e-02 3.02904671e-02 -2.21079340 0.08938006 10.75 -9.58562348e-03 -1.89153930e-02 2.12055717e-02 -2.03983978 0.03326888 11.00 -1.01898506e-02 -7.05771906e-03 1.23953400e-02 -2.53583526 0.01500293 11.25 -1.73801839e-02 1.47063148e-03 1.74422919e-02 3.05717832 0.03303367 11.50 -1.66092644e-02 -7.14317005e-03 1.80801699e-02 -2.73543432 0.03239425 11.75 -1.88662470e-02 -1.23175020e-02 2.25312257e-02 -2.56319153 0.03798398 12.00 -1.39460283e-02 -6.26355431e-03 1.52880286e-02 -2.71946397 0.01875947 12.25 -9.24400373e-03 -1.55109796e-03 9.37323369e-03 -2.97534630 0.00575640 12.50 -1.70622385e-03 -1.23548982e-02 1.24721573e-02 -1.70802929 0.01292321 12.75 5.58926951e-03 -1.46405701e-02 1.56711910e-02 -1.20610720 0.02183740 13.00 -9.32274392e-03 -1.12812767e-02 1.46349158e-02 -2.26142339 0.01739681 13.25 -1.21433246e-02 -1.12282850e-02 1.65388850e-02 -2.39532626 0.01822446 13.50 -1.12708812e-02 -2.23821058e-02 2.50597571e-02 -2.03729315 0.04440324 13.75 -8.00274026e-03 -1.95695236e-02 2.11426135e-02 -1.95898486 0.02836768 14.00 7.48371452e-03 -3.49089185e-02 3.57020808e-02 -1.35961448 0.04764551 14.25 1.03676694e-02 -4.62594598e-02 4.74070268e-02 -1.35031965 0.05543300 14.50 1.32876655e-02 -7.14414664e-03 1.50864471e-02 -0.49331397 0.00546593 14.75 1.84343939e-02 -2.12348895e-03 1.85562950e-02 -0.11468621 0.00863576 15.00 7.70981832e-03 -7.77656866e-03 1.09506310e-02 -0.78970840 0.00368398 15.25 2.64533700e-05 -1.67355806e-03 1.67376712e-03 -1.55499098 0.00009190 15.50 6.80940661e-03 -2.24122251e-02 2.34238309e-02 -1.27583356 0.01455176 15.75 4.15973927e-04 -2.44687504e-02 2.44722859e-02 -1.55379775 0.01610042 16.00 -1.70318020e-02 -3.40776785e-02 3.80968562e-02 -2.03427872 0.03866907 16.25 -6.21170342e-03 -3.92216895e-02 3.97105300e-02 -1.72786596 0.04443386 16.50 -1.36079562e-02 -9.84761626e-03 1.67973813e-02 -2.51515936 0.00895892 16.75 -1.20136970e-02 -4.99311947e-03 1.30100022e-02 -2.74769464 0.00458979 17.00 -2.10467922e-02 -1.56898910e-02 2.62514788e-02 -2.50099282 0.01561078 17.25 -1.03212900e-02 -2.14566213e-02 2.38099900e-02 -2.01915353 0.01232945 17.50 -7.63992038e-03 -3.56778924e-02 3.64867153e-02 -1.78174649 0.02634232 17.75 -7.06821710e-03 -4.20690933e-02 4.26587425e-02 -1.73725611 0.04171834 18.00 -1.91872682e-02 -1.94055307e-02 2.72896662e-02 -2.35053903 0.01531876 18.25 -9.14465048e-03 -1.70878670e-02 1.93809141e-02 -2.06217052 0.00831125 18.50 3.97892698e-02 -1.60541093e-02 4.29059485e-02 -0.38350136 0.02564692 18.75 5.48870068e-02 3.05023371e-03 5.49716967e-02 0.05551586 0.03128506 19.00 1.01249423e-01 7.85531711e-03 1.01553688e-01 0.07742872 0.07724229 19.25 6.39736641e-02 5.83766361e-03 6.42394584e-02 0.09099903 0.03927621 19.50 1.12196420e-01 -2.11717296e-02 1.14176525e-01 -0.18650922 0.10267065 19.75 6.66066864e-02 -5.54317435e-02 8.66552298e-02 -0.69408377 0.09292170 20.00 8.11193640e-02 -1.12405025e-01 1.38619049e-01 -0.94567413 0.14971758 20.25 3.40542460e-02 -6.59064393e-02 7.41845699e-02 -1.09387349 0.07286985 20.50 2.34347461e-02 -3.39741984e-02 4.12726724e-02 -0.96696194 0.01951192 20.75 3.44926585e-02 -7.51165453e-02 8.26573582e-02 -1.14032752 0.06508035 21.00 9.68097437e-02 -6.22871951e-02 1.15116555e-01 -0.57172008 0.06647803 21.25 1.25564772e-01 -3.44977127e-02 1.30217526e-01 -0.26812482 0.09050290 21.50 1.02128914e-01 1.72225346e-02 1.03570898e-01 0.16706344 0.05626555 21.75 3.43370385e-02 -1.08763001e-02 3.60184136e-02 -0.30675320 0.01569818 22.00 2.62184369e-02 -2.11363154e-02 3.36771474e-02 -0.67848716 0.01562893 22.25 -7.93108662e-03 3.17478535e-03 8.54291502e-03 2.76083079 0.00111825 22.50 -3.52460013e-02 5.94355723e-03 3.57436215e-02 2.97453365 0.01677643 22.75 -5.31781961e-03 -3.08558691e-02 3.13107627e-02 -1.74146362 0.01243297 23.00 3.46105233e-02 -6.15550884e-02 7.06181084e-02 -1.05858230 0.04174069 23.25 8.44503021e-02 -3.53560191e-02 9.15527259e-02 -0.39648894 0.07147496 23.50 1.17116721e-01 -2.16658705e-02 1.19103888e-01 -0.18292580 0.11010222 23.75 1.49261192e-01 -3.16597015e-03 1.49294765e-01 -0.02120776 0.14054671 24.00 2.42019511e-01 1.44772872e-02 2.42452131e-01 0.05974748 0.21582436 24.25 1.67660095e-01 -7.96453570e-02 1.85615976e-01 -0.44348148 0.09159089 24.50 1.70725722e-01 -1.16279339e-01 2.06562719e-01 -0.59792066 0.08657208 24.75 1.11863845e-01 -4.87192520e-02 1.22012644e-01 -0.41074966 0.06886005 25.00 8.00839010e-02 -3.66709916e-02 8.80806041e-02 -0.42941003 0.04432639 25.25 1.48056086e-01 -3.52054723e-02 1.52184197e-01 -0.23344928 0.07396889 25.50 1.47880068e-01 -3.28177648e-02 1.51477788e-01 -0.21838235 0.06293785 25.75 1.50294597e-01 -7.36494316e-02 1.67369963e-01 -0.45564290 0.10869891 26.00 2.21253033e-01 -8.30786792e-02 2.36336564e-01 -0.35920169 0.15303267 26.25 1.68269819e-01 -3.34420248e-02 1.71560779e-01 -0.19618419 0.08949786 26.50 9.84222157e-02 3.51804467e-03 9.84850708e-02 0.03572921 0.04059782 26.75 1.19748420e-01 2.02488527e-02 1.21448343e-01 0.16751039 0.05845363 27.00 1.23012827e-01 1.66700765e-02 1.24137211e-01 0.13469442 0.07006503 27.25 1.05855137e-01 1.10542195e-03 1.05860908e-01 0.01044240 0.06100083 27.50 9.72927429e-02 1.44363644e-02 9.83579505e-02 0.14730590 0.05215032 27.75 1.20870763e-01 -2.26446164e-02 1.22973655e-01 -0.18519888 0.05921112 28.00 8.46825658e-02 -1.82502908e-02 8.66268438e-02 -0.21226754 0.03388756 28.25 8.89158615e-02 -1.77700299e-02 9.06741661e-02 -0.19725343 0.03545539 28.50 7.42346200e-02 -8.18627943e-03 7.46846301e-02 -0.10983199 0.02632081 28.75 -2.06861319e-03 -6.08465876e-02 6.08817410e-02 -1.60478043 0.01293951 29.00 1.63090730e-02 -6.73260518e-02 6.92732496e-02 -1.33313428 0.02277601 29.25 1.36089881e-01 -4.98572345e-02 1.44935156e-01 -0.35117021 0.06743706 29.50 9.12437705e-02 -3.49093970e-02 9.76938670e-02 -0.36541249 0.03716767 29.75 1.09953521e-01 -4.37360493e-02 1.18332662e-01 -0.37858121 0.04218890 30.00 7.21768111e-02 -3.37137011e-02 7.96624485e-02 -0.43698195 0.02932736 30.25 6.90703481e-02 -3.99717916e-02 7.98026135e-02 -0.52461895 0.02398875 30.50 6.71837445e-02 -2.15139296e-02 7.05443456e-02 -0.30990723 0.02625828 30.75 8.56071370e-02 -5.78189258e-03 8.58021689e-02 -0.06743743 0.04026492 31.00 5.67946465e-02 -4.36115076e-02 7.16072305e-02 -0.65484683 0.03762108 31.25 6.53631383e-02 -8.38001751e-02 1.06277040e-01 -0.90837744 0.04689846 31.50 7.97940358e-02 -4.56752756e-02 9.19419325e-02 -0.51988915 0.03651439 31.75 1.55413361e-01 -4.16166049e-02 1.60888951e-01 -0.26164161 0.10464565 32.00 1.02427644e-01 -1.22186908e-02 1.03153860e-01 -0.11872988 0.04281696 32.25 9.78579709e-02 2.81199292e-02 1.01818038e-01 0.27981543 0.03028878 32.50 6.84799639e-02 -1.24066349e-03 6.84912017e-02 -0.01811519 0.02543311 32.75 2.95680644e-02 -6.85338675e-02 7.46402132e-02 -1.16348592 0.04003242 33.00 4.90261296e-02 -8.90692686e-02 1.01670527e-01 -1.06762535 0.07750328 33.25 9.03629714e-02 -6.84228027e-02 1.13345254e-01 -0.64809293 0.06862000 33.50 5.54047549e-02 -3.15868669e-02 6.37763046e-02 -0.51815240 0.01552794 33.75 6.28524184e-02 -4.32085712e-02 7.62719288e-02 -0.60226070 0.02263941 34.00 1.73933692e-02 7.58662604e-03 1.89759370e-02 0.41130131 0.00352727 34.25 2.12493149e-02 7.85486708e-03 2.26546313e-02 0.35407442 0.00393131 34.50 2.21473354e-02 -1.61767459e-02 2.74261112e-02 -0.63084843 0.00345295 34.75 5.11209313e-02 1.54389685e-02 5.34014172e-02 0.29329866 0.01046381 35.00 5.84975135e-02 -3.64769172e-02 6.89385566e-02 -0.55756570 0.01763381 35.25 1.06390538e-01 -5.39435193e-02 1.19284742e-01 -0.46925821 0.04365160 35.50 1.54715909e-01 -2.82081622e-03 1.54741622e-01 -0.01823021 0.08301082 35.75 1.48031182e-01 -1.63015146e-02 1.48926056e-01 -0.10968023 0.07307353 36.00 7.66133772e-02 -1.44961462e-01 1.63961688e-01 -1.08460282 0.06227941 36.25 4.03155757e-01 -4.76343788e-01 6.24049653e-01 -0.86842242 0.28420569 36.50 8.00394149e-01 -8.31484936e-01 1.15412217e+00 -0.80444800 0.56058205 36.75 5.44905431e-01 -4.38289215e-01 6.99299195e-01 -0.67738167 0.32040458 37.00 2.10185413e-01 -1.52649623e-01 2.59768773e-01 -0.62813473 0.12340864 37.25 1.84296420e-01 -1.52066465e-01 2.38933841e-01 -0.68987081 0.12135279 37.50 1.86706539e-01 -1.31695402e-01 2.28479781e-01 -0.61431451 0.10898332 37.75 2.23779525e-01 -1.35680019e-01 2.61698955e-01 -0.54504713 0.13727947 38.00 2.17781911e-01 -1.08662344e-01 2.43385426e-01 -0.46280748 0.11329785 38.25 2.01056566e-01 -1.17688516e-01 2.32968516e-01 -0.52957800 0.10859910 38.50 3.09415924e-01 -1.07591475e-01 3.27588369e-01 -0.33464615 0.19448623 38.75 3.73829073e-01 -1.12807085e-01 3.90478699e-01 -0.29307173 0.25538561 39.00 3.36273973e-01 -9.95423077e-02 3.50697671e-01 -0.28779729 0.16966207 39.25 2.20182719e-01 -9.62822388e-02 2.40313751e-01 -0.41222859 0.10074490 39.50 1.95177477e-01 -4.53556678e-02 2.00378103e-01 -0.22832922 0.06505307 39.75 2.54922283e-01 -8.46541579e-02 2.68610679e-01 -0.32062060 0.11022147 40.00 5.57950858e-01 -8.51628767e-02 5.64412859e-01 -0.15146605 0.31405583 40.25 5.13584874e-01 -1.30883349e-01 5.29999881e-01 -0.24953127 0.25506236 40.50 7.60021761e-01 -1.95386173e-01 7.84734881e-01 -0.25163074 0.34350027 40.75 6.78288676e-01 -1.77112673e-01 7.01030974e-01 -0.25541400 0.28582619 41.00 8.82326455e-01 -6.93433809e-03 8.82353704e-01 -0.00785899 0.39046180 41.25 9.03602193e-01 -9.36579411e-02 9.08443027e-01 -0.10328073 0.35783122 41.50 1.08487928e+00 -1.33192117e-01 1.09302479e+00 -0.12216005 0.39958201 41.75 8.24056251e-01 -1.60152065e-01 8.39474472e-01 -0.19195319 0.26451473 42.00 1.04084172e+00 6.52092794e-02 1.04288241e+00 0.06256875 0.28580714 42.25 9.96039677e-01 -1.53495789e-01 1.00779760e+00 -0.15290325 0.28477775 42.50 1.29035620e+00 -1.98806451e-01 1.30558153e+00 -0.15286895 0.34044277 42.75 2.24896780e+00 -1.21086108e-01 2.25222513e+00 -0.05378881 0.53693181 43.00 2.98937441e+00 -4.30892289e-01 3.02026944e+00 -0.14315529 0.63901320 43.25 1.96887895e+00 -6.51703509e-01 2.07393389e+00 -0.31965118 0.31958084 43.50 1.96488471e+00 -6.88152726e-01 2.08190444e+00 -0.33687569 0.24868847 43.75 9.78872458e-01 -4.08415260e-01 1.06065749e+00 -0.39527129 0.03422405 44.00 -6.92689224e-01 -1.08838435e+00 1.29011583e+00 -2.13757851 0.02524112 44.25 -1.78027743e+00 -1.09970247e+00 2.09254229e+00 -2.58824980 0.11069987 44.50 -1.78677060e+00 -7.51311269e-01 1.93830282e+00 -2.74355197 0.17429136 44.75 -7.85339419e-01 -4.20837788e-01 8.90989588e-01 -2.64966452 0.10824210 45.00 -7.03199653e-01 -2.91603052e-01 7.61263484e-01 -2.74849524 0.14830357 45.25 -4.23317600e-01 -1.72416262e-01 4.57083316e-01 -2.75481108 0.12802197 45.50 -4.72687693e-01 -2.72355533e-02 4.73471678e-01 -3.08403779 0.22677828 45.75 -3.89263212e-01 -1.11915219e-01 4.05031930e-01 -2.86163798 0.27196779 46.00 -3.76501526e-01 -8.41311331e-02 3.85786789e-01 -2.92174929 0.32576870 46.25 -1.98538726e-01 -1.25821348e-01 2.35050287e-01 -2.57673517 0.16895050 46.50 -1.76829985e-01 -1.14726152e-01 2.10786464e-01 -2.56606603 0.15214368 46.75 -1.23993810e-01 -6.07942465e-02 1.38095638e-01 -2.68573458 0.10186449 47.00 -8.58880887e-02 -7.04128515e-02 1.11061845e-01 -2.45488210 0.05917570 47.25 1.97509087e-02 -5.17310078e-03 2.04171342e-02 -0.25616293 0.00159252 47.50 1.88750437e-02 -7.06622408e-03 2.01543742e-02 -0.35821702 0.00161135 47.75 -1.03620013e-02 -3.91646264e-02 4.05122084e-02 -1.82944539 0.00758456 48.00 9.13497112e-03 -2.87259801e-02 3.01434841e-02 -1.26290520 0.00407862 48.25 4.89115460e-02 2.38160337e-02 5.44016801e-02 0.45312935 0.01342280 48.50 4.87304792e-02 5.61424299e-03 4.90528218e-02 0.11470437 0.01070641 48.75 4.90377761e-02 -4.20868149e-02 6.46220045e-02 -0.70926584 0.02011987 49.00 1.14298845e-01 -6.61761739e-02 1.32073889e-01 -0.52481647 0.07336287 49.25 2.36387433e-01 -8.42638223e-02 2.50956989e-01 -0.34242254 0.20459868 49.50 1.72762069e-01 -6.57161258e-02 1.84838691e-01 -0.36348352 0.07475536 49.75 1.78945000e-02 -9.48683793e-03 2.02537212e-02 -0.48747868 0.00017533 50.00 -4.93994548e-02 -7.60001581e-02 9.06439748e-02 -2.14716555 0.00248397 50.25 1.18974553e-01 -5.17398911e-02 1.29738046e-01 -0.41021092 0.01779377 50.50 7.94749599e-02 -2.95671359e-02 8.47967262e-02 -0.35616503 0.01625953 50.75 2.63384319e-02 -2.60687972e-02 3.70579976e-02 -0.78025322 0.00385919 51.00 3.57564949e-02 -4.62851578e-02 5.84879710e-02 -0.91303366 0.00755614 51.25 2.78805244e-02 3.06282701e-02 4.14175635e-02 0.83232664 0.00355635 51.50 -7.65526538e-03 1.15613164e-02 1.38660421e-02 2.15566186 0.00031359 51.75 1.03149100e-01 -5.17207268e-02 1.15389646e-01 -0.46478068 0.01971897 52.00 6.22877616e-02 -7.68970616e-02 9.89592004e-02 -0.88997853 0.01307574 52.25 7.65832003e-02 -1.91095816e-02 7.89313796e-02 -0.24453350 0.00735606 52.50 1.88717749e-01 1.49219665e-02 1.89306772e-01 0.07890612 0.03222540 52.75 3.57226632e-01 2.97736838e-02 3.58465255e-01 0.08315457 0.11802492 53.00 2.37943328e-01 1.54441216e-01 2.83670790e-01 0.57571921 0.09361644 53.25 1.99973073e-01 2.81977025e-01 3.45688115e-01 0.95393439 0.15345069 53.50 2.89686813e-01 3.28333468e-01 4.37859927e-01 0.84784983 0.16236847 53.75 4.69776139e-01 5.65242765e-01 7.34975512e-01 0.87737452 0.25165919 54.00 6.15572199e-01 2.25173139e-01 6.55463252e-01 0.35067608 0.18801618 54.25 8.18107169e-01 -1.88377224e-02 8.18324018e-01 -0.02302192 0.27797466 54.50 1.53819678e-01 -6.20057620e-01 6.38852053e-01 -1.32763194 0.10163153 54.75 -5.33212795e-01 -7.64472741e-01 9.32059255e-01 -2.17983636 0.12625870 55.00 -1.67158661e-01 9.06994086e-01 9.22269098e-01 1.75305080 0.08426151 55.25 6.60043729e-01 1.62680355e+00 1.75560460e+00 1.18535969 0.26835050 55.50 1.45345904e+00 9.79870493e-01 1.75290883e+00 0.59317547 0.35626060 55.75 1.80926347e+00 6.61237401e-01 1.92630974e+00 0.35039240 0.40345792 56.00 1.89732362e+00 1.10045422e-01 1.90051227e+00 0.05793544 0.44725400 56.25 1.93800795e+00 -6.87245706e-02 1.93922611e+00 -0.03544660 0.51264426 56.50 2.29878591e+00 -3.90073798e-01 2.33164625e+00 -0.16808581 0.60552006 56.75 2.49321115e+00 -5.24884016e-01 2.54786285e+00 -0.20749525 0.60678376 57.00 3.29414678e+00 -6.50475793e-01 3.35775547e+00 -0.19495603 0.61481782 57.25 4.10370079e+00 -1.33350931e+00 4.31492842e+00 -0.31418926 0.68654891 57.50 6.14509246e+00 -2.83378925e+00 6.76701728e+00 -0.43208478 0.73781590 57.75 6.23586127e+00 -4.66549024e+00 7.78798851e+00 -0.64232949 0.63590227 58.00 4.60675207e-01 -7.62369663e+00 7.63760250e+00 -1.51044296 0.51599250 58.25 -2.63639029e+00 -5.52491522e+00 6.12170254e+00 -2.01602350 0.54109698 58.50 -2.77767780e+00 -1.94837301e+00 3.39288245e+00 -2.52990121 0.62689288 58.75 -2.19176982e+00 -1.09668748e+00 2.45083218e+00 -2.67765215 0.61313740 59.00 -1.56706522e+00 -6.06000690e-01 1.68015780e+00 -2.77259491 0.69954337 59.25 -1.29013346e+00 -4.07156938e-01 1.35285665e+00 -2.83589256 0.70449048 59.50 -1.10962147e+00 -3.02700669e-01 1.15016847e+00 -2.87527633 0.76057119 59.75 -9.99417662e-01 -2.26441701e-01 1.02474949e+00 -2.91878090 0.75922206 60.00 -8.22112339e-01 -1.86999367e-01 8.43111772e-01 -2.91793603 0.74309466 60.25 -7.16633518e-01 -7.81507319e-02 7.20882193e-01 -3.03296932 0.63433635 60.50 -5.67139947e-01 1.89083070e-02 5.67455059e-01 3.10826524 0.60306399 60.75 -4.38783256e-01 1.87223223e-02 4.39182503e-01 3.09894979 0.46605141 61.00 -2.55202332e-01 1.04097564e-01 2.75616642e-01 2.75429275 0.28789915 61.25 -1.77102252e-01 1.00215782e-01 2.03490567e-01 2.62665145 0.15260559 61.50 -6.06091923e-02 5.68181525e-02 8.30769321e-02 2.38846741 0.04131758 61.75 2.46598511e-02 4.60167217e-02 5.22077287e-02 1.07885147 0.01586512 62.00 8.23118136e-02 7.09441198e-02 1.08666015e-01 0.71135917 0.10876299 62.25 2.27210446e-01 3.92211696e-02 2.30570785e-01 0.17093590 0.33782695 62.50 3.56154757e-01 3.18572323e-02 3.57576697e-01 0.08921031 0.68132930 62.75 4.51311489e-01 3.23356768e-02 4.52468403e-01 0.07152602 0.64709476 63.00 5.30885042e-01 1.58667804e-03 5.30887413e-01 0.00298873 0.79633023 63.25 6.61994767e-01 -8.29258925e-02 6.67168476e-01 -0.12461757 0.78910575 63.50 8.33355281e-01 -2.13052761e-01 8.60158417e-01 -0.25029538 0.85227056 63.75 1.01761808e+00 -4.07613352e-01 1.09621859e+00 -0.38098587 0.77717886 64.00 1.22825368e+00 -8.20798648e-01 1.47726691e+00 -0.58910816 0.78807681 64.25 6.46739027e-01 -1.42971995e+00 1.56919423e+00 -1.14598684 0.70562089 64.50 -9.74733078e-03 -1.70852775e+00 1.70855556e+00 -1.57650137 0.77993712 64.75 -7.66337160e-01 -1.05027590e+00 1.30013542e+00 -2.20114780 0.73926114 65.00 -9.19966781e-01 -6.85835692e-01 1.14747962e+00 -2.50097745 0.85996291 65.25 -6.61217317e-01 -4.17027448e-01 7.81741794e-01 -2.57890746 0.85078801 65.50 -5.44324302e-01 -2.77758879e-01 6.11096507e-01 -2.66975334 0.84957057 65.75 -4.65468432e-01 -1.39282671e-01 4.85860601e-01 -2.85084134 0.70791045 66.00 -3.77293856e-01 -1.13347352e-01 3.93952124e-01 -2.84974880 0.77699486 66.25 -3.21878946e-01 -3.93129952e-02 3.24270825e-01 -3.02005862 0.69657668 66.50 -2.64338594e-01 -1.55660767e-02 2.64796516e-01 -3.08277369 0.62798366 66.75 -1.91098797e-01 7.48998662e-03 1.91245523e-01 3.10241839 0.50958956 67.00 -1.65981222e-01 2.40074134e-02 1.67708443e-01 2.99794949 0.51179542 67.25 -1.20617063e-01 2.71951332e-02 1.23644859e-01 2.91983403 0.38591600 67.50 -1.04316624e-01 2.39845424e-02 1.07038387e-01 2.91559966 0.31462002 67.75 -5.33443260e-02 4.39201353e-02 6.90984472e-02 2.45278541 0.14148094 68.00 -3.08110068e-02 5.95018739e-02 6.70059037e-02 2.04859473 0.15833819 68.25 -9.87143640e-04 6.42759796e-02 6.42835594e-02 1.58615301 0.17935873 68.50 1.00151444e-02 6.80363564e-02 6.87695347e-02 1.42464311 0.14106637 68.75 3.98205104e-02 1.20164743e-03 3.98386371e-02 0.03016744 0.04750659 69.00 5.44400385e-02 -2.38995562e-02 5.94550803e-02 -0.41367461 0.07498841 69.25 1.00353579e-01 -2.59062845e-02 1.03643507e-01 -0.25263450 0.10580172 69.50 1.09135024e-01 2.62514715e-02 1.12247910e-01 0.23605666 0.14527391 69.75 1.23803242e-01 6.78183660e-02 1.41161515e-01 0.50114606 0.25116347 70.00 1.45897249e-01 5.42524892e-02 1.55657765e-01 0.35600977 0.18483571 70.25 1.55209676e-01 3.33446510e-02 1.58751092e-01 0.21161955 0.17021906 70.50 1.20879977e-01 2.76469822e-02 1.24001308e-01 0.22484696 0.10303800 70.75 1.45198321e-01 8.16929816e-02 1.66602208e-01 0.51248847 0.18247347 71.00 1.62866590e-01 4.21969320e-02 1.68244190e-01 0.25351450 0.13566921 71.25 1.36925238e-01 2.45573225e-02 1.39109967e-01 0.17746172 0.09883917 71.50 5.72226198e-02 1.93665093e-02 6.04110081e-02 0.32634084 0.02305803 71.75 3.28205890e-02 -5.26913568e-02 6.20771306e-02 -1.01372027 0.03154779 72.00 4.98091768e-02 -6.14357211e-02 7.90904666e-02 -0.88953316 0.04693909 72.25 9.04067281e-02 -5.39431617e-03 9.05675170e-02 -0.05959654 0.07219989 72.50 1.00746986e-01 4.13633459e-02 1.08907674e-01 0.38958218 0.10974918 72.75 1.25720316e-01 3.54200405e-02 1.30614613e-01 0.27461852 0.19747556 73.00 1.42792622e-01 9.43577199e-03 1.43104041e-01 0.06598432 0.20438043 73.25 1.80418352e-01 -6.33786984e-03 1.80529639e-01 -0.03511430 0.41669747 73.50 1.67492796e-01 -2.09424777e-02 1.68796991e-01 -0.12438955 0.32633581 73.75 1.29299002e-01 -5.15728146e-02 1.39204839e-01 -0.37952733 0.26415969 74.00 1.47922996e-01 -4.89721147e-02 1.55818743e-01 -0.31970760 0.26042555 74.25 1.59886420e-01 -5.24122798e-02 1.68257880e-01 -0.31677085 0.36235695 74.50 1.58934970e-01 -1.01917969e-02 1.59261412e-01 -0.06403790 0.30131497 74.75 1.47284655e-01 -4.02701562e-04 1.47285206e-01 -0.00273417 0.32411465 75.00 1.17872569e-01 -1.47541854e-02 1.18792376e-01 -0.12452301 0.20519133 75.25 1.00885952e-01 -1.79049318e-02 1.02462490e-01 -0.17564801 0.16835511 75.50 1.25979821e-01 2.19396135e-02 1.27875964e-01 0.17242256 0.14985780 75.75 1.21315576e-01 2.57770546e-02 1.24023891e-01 0.20936563 0.19613048 76.00 1.42940789e-01 1.01329912e-01 1.75213642e-01 0.61667039 0.36183493 76.25 1.54264122e-01 1.10104559e-01 1.89526867e-01 0.61988840 0.36211794 76.50 2.17828445e-01 1.27349863e-01 2.52323640e-01 0.52904417 0.44641010 76.75 2.69525836e-01 1.33534863e-01 3.00791849e-01 0.45999589 0.57194890 77.00 3.03563857e-01 1.44220956e-01 3.36081388e-01 0.44352392 0.55217516 77.25 3.44479525e-01 1.57945822e-01 3.78963093e-01 0.42990471 0.60668339 77.50 3.73969906e-01 1.36797417e-01 3.98204751e-01 0.35067880 0.51772081 77.75 3.72915980e-01 1.30714211e-01 3.95161401e-01 0.33713728 0.53551023 78.00 3.98340825e-01 1.77176496e-01 4.35966654e-01 0.41850966 0.49639606 78.25 3.94802576e-01 2.17695625e-01 4.50844162e-01 0.50392032 0.45444242 78.50 3.53485245e-01 1.60130306e-01 3.88063826e-01 0.42534942 0.25046269 78.75 4.45533456e-01 2.40182033e-01 5.06149651e-01 0.49442740 0.28480424 79.00 7.27495570e-01 2.95957404e-01 7.85391997e-01 0.38636906 0.38805865 79.25 8.87541991e-01 3.11287858e-01 9.40548199e-01 0.33732526 0.39176528 79.50 1.09783965e+00 1.96548786e-01 1.11529518e+00 0.17715547 0.45045126 79.75 1.27299856e+00 1.74263679e-01 1.28487087e+00 0.13604667 0.42305355 80.00 2.17193035e+00 1.54413041e-01 2.17741242e+00 0.07097542 0.51080053 80.25 2.87112190e+00 -2.93633164e-01 2.88609795e+00 -0.10191688 0.46416724 80.50 3.24813531e+00 -4.72466610e+00 5.73348522e+00 -0.96851942 0.52702870 80.75 -3.39872951e-01 -4.89891493e+00 4.91069049e+00 -1.64006253 0.48480308 81.00 -1.94542044e+00 -3.17873115e+00 3.72679385e+00 -2.12000113 0.73794862 81.25 -1.96224712e+00 -2.55446163e+00 3.22113147e+00 -2.22582182 0.74971290 81.50 -2.08952143e+00 -1.57975012e+00 2.61948664e+00 -2.49424069 0.83341409 81.75 -1.82632765e+00 -1.00939005e+00 2.08670577e+00 -2.63668778 0.89170543 82.00 -1.46807179e+00 -7.30527895e-01 1.63978833e+00 -2.67985849 0.93071826 82.25 -1.29176633e+00 -6.15345562e-01 1.43084255e+00 -2.69703542 0.91125498 82.50 -1.15790976e+00 -5.68240957e-01 1.28982665e+00 -2.68537466 0.86843287 82.75 -1.14068915e+00 -4.05893189e-01 1.21075225e+00 -2.79973216 0.86574675 83.00 -1.11671072e+00 -2.68383252e-01 1.14850878e+00 -2.90573214 0.91839418 83.25 -1.14330619e+00 -7.54492780e-02 1.14579302e+00 -3.07569601 0.83785755 83.50 -8.72431253e-01 4.33529688e-01 9.74209568e-01 2.68041102 0.67191728 83.75 -4.43407184e-01 5.25354036e-01 6.87464031e-01 2.27180606 0.63248282 84.00 -1.83847910e-01 3.45096477e-01 3.91013596e-01 2.06029434 0.49995383 84.25 -1.53213939e-01 1.18367794e-01 1.93611585e-01 2.48380539 0.21112998 84.50 -1.49800593e-01 2.37447809e-02 1.51670803e-01 2.98439126 0.25495881 84.75 -2.03253402e-01 -1.02758567e-02 2.03512994e-01 -3.09107879 0.37220692 85.00 -2.02017736e-01 -4.03926829e-02 2.06016345e-01 -2.94424880 0.48199752 85.25 -1.71031575e-01 -6.03676964e-02 1.81372706e-01 -2.80228126 0.42998409 85.50 -1.77134171e-01 -9.03759874e-02 1.98857571e-01 -2.66980883 0.63943756 85.75 -1.58039666e-01 -6.13182886e-02 1.69518343e-01 -2.77147977 0.53199583 86.00 -1.61877521e-01 -5.33206511e-02 1.70433048e-01 -2.82339632 0.61397417 86.25 -1.52829275e-01 -5.87067425e-02 1.63717039e-01 -2.77483925 0.53061037 86.50 -1.48404240e-01 -5.63358542e-02 1.58737352e-01 -2.77878577 0.57459404 86.75 -1.49321952e-01 -5.02606790e-02 1.57553740e-01 -2.81691154 0.53591821 87.00 -1.56067378e-01 -4.99168734e-02 1.63855793e-01 -2.83203321 0.52470021 87.25 -1.13480811e-01 -4.46090308e-02 1.21933835e-01 -2.76705078 0.39944630 87.50 -1.02570494e-01 -3.91613690e-02 1.09792163e-01 -2.77687410 0.40473009 87.75 -1.02543264e-01 -6.93821914e-02 1.23810377e-01 -2.54673513 0.43767271 88.00 -1.01813536e-01 -7.95221398e-02 1.29188881e-01 -2.47850974 0.47537616 88.25 -6.08948012e-02 -9.77219742e-02 1.15142351e-01 -2.12805943 0.43512220 88.50 -4.57306965e-02 -9.69764471e-02 1.07218132e-01 -2.01143827 0.41174140 88.75 1.28208992e-02 -1.33990181e-01 1.34602169e-01 -1.47540139 0.31725271 89.00 -3.27260988e-02 -1.77598024e-01 1.80588083e-01 -1.75302276 0.29059440 89.25 -2.13206221e-01 -8.01737563e-02 2.27782185e-01 -2.78191179 0.64035576 89.50 -2.09568355e-01 -7.19933062e-02 2.21589557e-01 -2.81069211 0.75357475 89.75 -1.65912991e-01 -3.67315454e-02 1.69930360e-01 -2.92371651 0.68677203 90.00 -1.49126823e-01 -3.85704807e-02 1.54034059e-01 -2.88849690 0.62464642 90.25 -1.28632826e-01 -3.60993509e-02 1.33602272e-01 -2.86799177 0.64316691 90.50 -1.23540713e-01 -4.37701139e-02 1.31065368e-01 -2.80109484 0.57257520 90.75 -7.66221406e-02 -3.21373915e-02 8.30888943e-02 -2.74445188 0.41092785 91.00 -7.61506251e-02 -4.16179152e-02 8.67811532e-02 -2.64142439 0.39677517 91.25 -8.52442613e-02 -4.26792023e-02 9.53315184e-02 -2.67740958 0.47697068 91.50 -8.93626593e-02 -3.49416873e-02 9.59510624e-02 -2.76886028 0.42318018 91.75 -8.01830353e-02 -3.52750366e-02 8.75993571e-02 -2.72714324 0.43912804 92.00 -7.31846312e-02 -2.15383266e-02 7.62882019e-02 -2.85537226 0.37221935 92.25 -7.23265485e-02 -1.55503886e-02 7.39793498e-02 -2.92981411 0.51900953 92.50 -5.87867706e-02 -1.85141869e-02 6.16332663e-02 -2.83648825 0.33639611 92.75 -4.23313671e-02 -1.16825049e-02 4.39138425e-02 -2.87231789 0.19959560 93.00 -3.80740851e-02 -1.86738327e-02 4.24069332e-02 -2.68560577 0.15715343 93.25 -2.70894060e-02 -2.26762587e-02 3.53277317e-02 -2.44464169 0.13146344 93.50 -2.34791111e-02 -3.28615575e-02 4.03875057e-02 -2.19117819 0.13876629 93.75 -2.24030882e-02 -5.81416525e-02 6.23085076e-02 -1.93858303 0.34492672 94.00 -3.65160586e-02 -6.87586640e-02 7.78535574e-02 -2.05899437 0.38998156 94.25 -4.82743464e-02 -5.66861833e-02 7.44562684e-02 -2.27622256 0.39787548 94.50 -5.79346181e-02 -5.67772249e-02 8.11176506e-02 -2.36628372 0.41097109 94.75 -6.78266764e-02 -5.69869422e-02 8.85887668e-02 -2.44282449 0.46856468 95.00 -6.84378647e-02 -2.37640798e-02 7.24463443e-02 -2.80738245 0.24366883 95.25 -6.80248397e-02 5.43874571e-03 6.82419136e-02 3.06181002 0.24077858 95.50 -3.02340068e-02 2.03816620e-02 3.64624096e-02 2.54844066 0.09491707 95.75 -4.26013490e-03 1.89091847e-02 1.93831374e-02 1.79239104 0.03257270 96.00 1.60910707e-02 8.75557087e-03 1.83189131e-02 0.49832228 0.02463146 96.25 4.11643227e-02 -1.11397700e-03 4.11793930e-02 -0.02705511 0.10935906 96.50 6.73816357e-02 -3.23165135e-02 7.47304614e-02 -0.44719822 0.32974795 96.75 7.21011624e-02 -5.76694148e-02 9.23273471e-02 -0.67464355 0.47923991 97.00 4.59724491e-02 -8.71383469e-02 9.85218634e-02 -1.08532893 0.33542586 97.25 2.34962658e-02 -9.23434642e-02 9.52858326e-02 -1.32163921 0.29153873 97.50 -4.18355687e-02 -9.35593015e-02 1.02486866e-01 -1.99128236 0.20377364 97.75 -7.81131359e-02 -9.71065651e-02 1.24624825e-01 -2.24821829 0.23494593 98.00 -8.75830420e-02 3.36841878e-02 9.38371661e-02 2.77443471 0.09252826 98.25 -9.53792967e-02 1.06897092e-01 1.43262691e-01 2.29931503 0.11866801 98.50 -1.43323076e-01 1.03674775e-01 1.76889691e-01 2.51535754 0.13099999 98.75 -1.04964255e-01 1.46045251e-01 1.79851911e-01 2.19396961 0.08098251 99.00 2.59013567e-01 4.84712816e-02 2.63509949e-01 0.18499822 0.12045873 99.25 3.05602069e-01 -1.17292703e-01 3.27338056e-01 -0.36647083 0.20744566 99.50 1.38336401e-01 -1.95874961e-01 2.39799834e-01 -0.95588902 0.21677484 99.75 1.13819222e-01 -1.47278897e-01 1.86134061e-01 -0.91285330 0.08936003 100.00 2.29954330e-01 -2.49021375e-01 3.38955217e-01 -0.82518511 0.10278015 100.25 1.66842111e-01 -1.88553639e-01 2.51771255e-01 -0.84641346 0.13473507 100.50 7.82203312e-02 -6.95286506e-02 1.04654926e-01 -0.72663854 0.16123348 100.75 9.54810878e-02 -5.42475708e-02 1.09815468e-01 -0.51667101 0.20428147 101.00 6.51706039e-02 -1.57721354e-01 1.70655305e-01 -1.17896192 0.37232876 101.25 7.06049971e-03 -1.52857501e-01 1.53020477e-01 -1.52463906 0.29164091 101.50 -1.00848625e-01 -3.54566323e-02 1.06900038e-01 -2.80350855 0.24366278 101.75 -1.05895902e-01 2.84786217e-02 1.09658442e-01 2.87887806 0.22220439 102.00 -7.94492638e-02 1.19953605e-01 1.43878605e-01 2.15579288 0.24223570 102.25 -7.77028010e-02 2.10272835e-01 2.24170449e-01 1.92476562 0.35957803 102.50 -7.50074830e-02 3.64564721e-01 3.72200965e-01 1.77371007 0.58793386 102.75 1.54552005e-01 5.60735371e-01 5.81644633e-01 1.30185028 0.58358368 103.00 6.04808399e-01 5.60939150e-01 8.24891466e-01 0.74778405 0.64894169 103.25 5.57865941e-01 1.67059577e-01 5.82342950e-01 0.29096302 0.62961850 103.50 4.05212959e-01 8.38620351e-02 4.13799931e-01 0.20407684 0.82785182 103.75 3.86061800e-01 1.46711090e-01 4.12998617e-01 0.36316423 0.81311717 104.00 4.08687699e-01 1.97776148e-01 4.54027576e-01 0.45070898 0.81467733 104.25 4.28292602e-01 2.28752159e-01 4.85553399e-01 0.49055598 0.81703538 104.50 4.79094744e-01 2.64328274e-01 5.47175667e-01 0.50416619 0.86515435 104.75 5.62427695e-01 2.59061083e-01 6.19223350e-01 0.43164394 0.89468300 105.00 5.66110082e-01 2.45873020e-01 6.17198644e-01 0.40973835 0.88651400 105.25 5.73173297e-01 2.39132804e-01 6.21057265e-01 0.39525276 0.86963194 105.50 5.93637714e-01 2.24600063e-01 6.34705384e-01 0.36170034 0.88719605 105.75 6.11341480e-01 1.79321807e-01 6.37098671e-01 0.28532185 0.88546784 106.00 6.68731908e-01 1.35082709e-01 6.82238744e-01 0.19931626 0.87988155 106.25 6.54584944e-01 8.51122466e-02 6.60095101e-01 0.12929935 0.84761932 106.50 6.09018419e-01 6.42580237e-02 6.12398995e-01 0.10512187 0.85857236 106.75 5.73018576e-01 6.30065295e-02 5.76472125e-01 0.10951553 0.86335264 107.00 5.42867097e-01 9.05321658e-02 5.50364205e-01 0.16524603 0.85103342 107.25 5.36399919e-01 1.28293930e-01 5.51528970e-01 0.23476561 0.85289399 107.50 5.29933924e-01 1.45985746e-01 5.49674269e-01 0.26881162 0.86764356 107.75 4.91634284e-01 1.92996951e-01 5.28159154e-01 0.37407793 0.79682555 108.00 4.40464858e-01 2.43808869e-01 5.03440221e-01 0.50554649 0.75770623 108.25 3.68266682e-01 1.49142698e-01 3.97320895e-01 0.38479689 0.54621667 108.50 4.13112431e-01 1.14521544e-01 4.28692273e-01 0.27042562 0.53413048 108.75 3.90149412e-01 1.47815139e-01 4.17212032e-01 0.36215750 0.61328383 109.00 2.84334426e-01 1.38802492e-01 3.16405116e-01 0.45413593 0.51651051 109.25 1.45117989e-01 1.40942596e-01 2.02296925e-01 0.77080302 0.16281242 109.50 1.13461054e-01 1.35323861e-01 1.76595465e-01 0.87305134 0.06464543 109.75 2.80316874e-01 2.85944200e-01 4.00426816e-01 0.79533553 0.34105084 110.00 1.65752484e-01 2.90098387e-01 3.34112197e-01 1.05169705 0.32442937 110.25 -7.46450948e-02 3.91408618e-01 3.98462792e-01 1.75924235 0.38409840 110.50 -1.38376292e-01 4.97617616e-01 5.16499071e-01 1.84202146 0.43682935 110.75 -4.88418575e-01 4.98141458e-01 6.97637167e-01 2.34633947 0.35540304 111.00 -5.41052885e-01 5.32438170e-01 7.59097246e-01 2.36421927 0.35881938 111.25 -7.34306607e-01 1.10044109e+00 1.32294247e+00 2.15922612 0.42014877 111.50 -7.16000535e-01 1.70829231e+00 1.85227411e+00 1.96768653 0.44152720 111.75 -2.99147165e-01 3.48884136e+00 3.50164291e+00 1.65633110 0.62551373 112.00 1.67722674e+00 2.93882039e+00 3.38374863e+00 1.05218885 0.55268686 112.25 2.96810316e+00 1.28372198e+00 3.23381795e+00 0.40821095 0.82564675 112.50 2.22669600e+00 6.64011145e-01 2.32359331e+00 0.28980889 0.81617935 112.75 1.42114653e+00 2.01213805e-01 1.43532033e+00 0.14065067 0.83648621 113.00 1.22334548e+00 9.12310673e-02 1.22674255e+00 0.07443727 0.82726043 113.25 1.03617360e+00 -7.69041074e-02 1.03902357e+00 -0.07408350 0.84730008 113.50 9.76254872e-01 -1.11031944e-01 9.82548557e-01 -0.11324593 0.84890977 113.75 9.29698402e-01 -1.08702441e-01 9.36031698e-01 -0.11639378 0.85644417 114.00 8.22742526e-01 -1.12216884e-01 8.30360098e-01 -0.13555721 0.79431668 114.25 7.57211492e-01 -1.23654901e-01 7.67241669e-01 -0.16187414 0.79359561 114.50 6.98839586e-01 -2.59455449e-01 7.45448789e-01 -0.35549310 0.70719012 114.75 7.08082908e-01 -4.54985262e-01 8.41660854e-01 -0.57112671 0.74539032 115.00 6.76859305e-01 -4.56433644e-01 8.16376255e-01 -0.59329646 0.71795676 115.25 5.02865335e-01 -4.47317343e-01 6.73027749e-01 -0.72700430 0.72631536 115.50 4.58368015e-01 -3.78439231e-01 5.94405156e-01 -0.69017070 0.74495925 115.75 4.36171148e-01 -3.12625703e-01 5.36637774e-01 -0.62187939 0.82838068 116.00 3.83208800e-01 -2.45951252e-01 4.55347123e-01 -0.57060360 0.86351029 116.25 3.69453694e-01 -2.03215507e-01 4.21654567e-01 -0.50287641 0.88304019 116.50 3.79339252e-01 -1.06128082e-01 3.93905366e-01 -0.27279624 0.81773366 116.75 3.92105464e-01 -1.88417345e-02 3.92557901e-01 -0.04801579 0.83642599 117.00 4.29500138e-01 3.96856079e-02 4.31329707e-01 0.09213790 0.82943975 117.25 4.55366074e-01 8.66528470e-02 4.63537461e-01 0.18804445 0.83044442 117.50 4.61598719e-01 1.51445177e-01 4.85807594e-01 0.31702269 0.78760822 117.75 4.60273606e-01 1.81756534e-01 4.94860819e-01 0.37609175 0.80864473 118.00 4.15838232e-01 1.50394633e-01 4.42199029e-01 0.34702983 0.77141334 118.25 3.72780241e-01 1.58129150e-01 4.04932015e-01 0.40118323 0.69308906 118.50 3.72592514e-01 2.95991589e-01 4.75853131e-01 0.67132371 0.57379520 118.75 4.50259226e-01 3.02441204e-01 5.42405801e-01 0.59148232 0.60451590 119.00 5.25213838e-01 3.39816376e-01 6.25559546e-01 0.57426742 0.64629694 119.25 4.99715397e-01 3.18794806e-01 5.92744132e-01 0.56785947 0.58310549 119.50 4.07409014e-01 1.05765383e-01 4.20913793e-01 0.25399796 0.38682034 119.75 2.72417225e-01 6.08691615e-02 2.79134734e-01 0.21983001 0.23901173 120.00 -2.33050632e-02 1.51308256e-01 1.53092502e-01 1.72361913 0.06439482 120.25 -9.31865810e-02 3.82887304e-01 3.94063988e-01 1.80953345 0.31983080 120.50 -3.87265460e-02 6.32830177e-01 6.34014020e-01 1.63191590 0.51344580 120.75 1.05204261e-01 7.91088152e-01 7.98052881e-01 1.43858532 0.57429347 121.00 3.60577543e-01 8.77648564e-01 9.48832528e-01 1.18097590 0.73261500 121.25 3.40893188e-01 7.57393172e-01 8.30573646e-01 1.14786965 0.73650783 121.50 3.76442582e-01 5.88020948e-01 6.98195999e-01 1.00135143 0.68954422 121.75 2.50246106e-01 5.65488208e-01 6.18385015e-01 1.15417089 0.64170973 122.00 5.26793268e-02 5.69603220e-01 5.72034038e-01 1.47857441 0.51904120 122.25 -1.85834271e-01 7.10490092e-01 7.34391277e-01 1.82662305 0.43490473 122.50 -7.25580972e-01 1.59335185e+00 1.75078208e+00 1.99811546 0.47009242 122.75 1.31383121e-01 1.66918191e+00 1.67434458e+00 1.49224719 0.33788266 123.00 1.60283156e+00 6.85592868e-01 1.74330335e+00 0.40418795 0.50653110 123.25 1.41023811e+00 3.38387735e-01 1.45026818e+00 0.23549844 0.57897979 123.50 7.95686806e-01 1.95604311e-01 8.19376922e-01 0.24105086 0.42931864 123.75 5.00990577e-01 4.62375153e-01 6.81749470e-01 0.74533574 0.32659992 124.00 -5.25795783e-01 4.71094795e-01 7.05968492e-01 2.41101112 0.20411770 124.25 -8.07850946e-01 1.16457923e-02 8.07934883e-01 3.12717788 0.22379262 124.50 -7.95249218e-01 -2.55333422e-01 8.35234384e-01 -2.83091626 0.35951256 124.75 -4.87560742e-01 -1.54322007e-01 5.11400782e-01 -2.83505098 0.26384721 125.00 -3.69742403e-01 -6.27801410e-02 3.75034386e-01 -2.97340246 0.27386659 125.25 -2.90184619e-01 -4.53558585e-02 2.93707792e-01 -2.98654710 0.22018390 125.50 -3.67737257e-01 5.96153616e-04 3.67737740e-01 3.13997151 0.41919836 125.75 -3.50064235e-01 7.57936285e-02 3.58175436e-01 2.92837033 0.45406702 126.00 -3.31671662e-01 1.20738593e-01 3.52964445e-01 2.79247361 0.56939872 126.25 -3.41955088e-01 1.60669829e-01 3.77820163e-01 2.70234929 0.50918455 126.50 -3.91300781e-01 2.14805278e-01 4.46382805e-01 2.63955454 0.53436050 126.75 -4.27032760e-01 1.21968617e-01 4.44109583e-01 2.86338121 0.36871563 127.00 -4.87347489e-01 6.64424654e-02 4.91855849e-01 3.00609316 0.41915120 127.25 -5.49734978e-01 1.26576396e-01 5.64118897e-01 2.91528698 0.42486869 127.50 -6.81434383e-01 1.13017170e-01 6.90742860e-01 2.97723685 0.53929997 127.75 -9.76751632e-01 2.12758002e-01 9.99654799e-01 2.92712074 0.61833228 128.00 -1.35649459e+00 4.78769102e-01 1.43850528e+00 2.80229591 0.69249350 128.25 -1.66572966e+00 1.04820085e+00 1.96809053e+00 2.57992559 0.72080347 128.50 -1.94006872e+00 1.65004639e+00 2.54686469e+00 2.43680302 0.75674577 128.75 -2.20849941e+00 3.79130167e+00 4.38764607e+00 2.09826182 0.78223424 129.00 -1.20318476e+00 5.15835366e+00 5.29681659e+00 1.79994900 0.74042298 129.25 2.62198485e+00 5.45213158e+00 6.04983829e+00 1.12253698 0.72026261 129.50 4.25864384e+00 4.37353126e+00 6.10441013e+00 0.79870659 0.71937060 129.75 5.02048579e+00 1.65084864e+00 5.28493886e+00 0.31768532 0.72690261 130.00 5.27021058e+00 8.04106902e-01 5.33120131e+00 0.15140817 0.76904060 130.25 4.92148484e+00 -6.11276466e-01 4.95930156e+00 -0.12357284 0.74174772 130.50 4.64137019e+00 -1.73729236e+00 4.95585532e+00 -0.35816203 0.70404356 130.75 4.86125542e+00 -4.03301791e+00 6.31641020e+00 -0.69254562 0.80974180 131.00 5.44652131e+00 -5.16023276e+00 7.50283923e+00 -0.75841356 0.85600613 131.25 4.05050852e+00 -6.88954268e+00 7.99202212e+00 -1.03930561 0.73939374 131.50 9.17648086e-01 -7.08345594e+00 7.14264839e+00 -1.44196576 0.67757741 131.75 -1.74797213e+00 -5.39286886e+00 5.66907762e+00 -1.88423804 0.58758486 132.00 -3.15089739e+00 -3.27314406e+00 4.54330567e+00 -2.33716723 0.49530463 132.25 -2.46342572e+00 -6.42890205e-01 2.54593286e+00 -2.88631243 0.53212858 132.50 -1.78665264e+00 -9.21025621e-01 2.01007856e+00 -2.66561934 0.63760431 132.75 -1.60755440e+00 -1.65950163e+00 2.31044948e+00 -2.34029551 0.85461216 133.00 -1.64288393e+00 -1.52068392e+00 2.23864852e+00 -2.39480257 0.84104905 133.25 -1.51583237e+00 -1.30298151e+00 1.99887683e+00 -2.43156225 0.83179265 133.50 -1.36034356e+00 -1.25478760e+00 1.85068272e+00 -2.39653614 0.73621474 133.75 -1.39673271e+00 -1.69513346e+00 2.19643796e+00 -2.25998094 0.83244391 134.00 -1.45820944e+00 -1.50320232e+00 2.09427600e+00 -2.34100261 0.80014076 134.25 -1.22131615e+00 -8.44170969e-01 1.48466756e+00 -2.53679871 0.79265893 134.50 -9.96010812e-01 -8.17503172e-01 1.28854529e+00 -2.45431034 0.74973297 134.75 -8.08955864e-01 -8.12148307e-01 1.14629598e+00 -2.35422519 0.79856697 135.00 -5.88063708e-01 -8.20685520e-01 1.00962550e+00 -2.19254474 0.74294641 135.25 -3.06558821e-01 -9.42681584e-01 9.91275380e-01 -1.88520793 0.78798597 135.50 -1.43305311e-03 -9.57949332e-01 9.57950404e-01 -1.57229228 0.74014700 135.75 3.36702773e-01 -9.97927776e-01 1.05319922e+00 -1.24538850 0.76246565 136.00 6.43511857e-01 -9.18428518e-01 1.12143589e+00 -0.95962336 0.59671764 136.25 1.39231948e+00 -7.46656759e-01 1.57988919e+00 -0.49223953 0.65794893 136.50 2.12002404e+00 -6.30332132e-01 2.21174603e+00 -0.28899912 0.59632092 136.75 2.68936088e+00 -3.62267870e-01 2.71365067e+00 -0.13389809 0.51392996 137.00 2.28029686e+00 2.52313776e-01 2.29421360e+00 0.11020125 0.32523123 137.25 2.70889410e+00 6.69466342e-01 2.79039288e+00 0.24228170 0.36841600 137.50 2.45954967e+00 -5.08026923e-01 2.51146888e+00 -0.20368834 0.35568958 137.75 2.17871141e+00 -4.34358377e-01 2.22158741e+00 -0.19678472 0.40522478 138.00 1.69661746e+00 -1.94097535e-03 1.69661857e+00 -0.00114403 0.39641740 138.25 1.60151023e+00 1.72660627e-01 1.61079071e+00 0.10739631 0.43109867 138.50 1.36037762e+00 3.63580718e-01 1.40812578e+00 0.26116050 0.57463610 138.75 1.28370855e+00 6.17912160e-01 1.42468350e+00 0.44861600 0.69219063 139.00 1.06417847e+00 4.01778752e-01 1.13749812e+00 0.36100291 0.60434285 139.25 9.77396986e-01 3.05462118e-01 1.02401757e+00 0.30290869 0.55534097 139.50 8.11256732e-01 3.64416371e-01 8.89346263e-01 0.42218829 0.52719392 139.75 7.79091679e-01 2.62402785e-01 8.22094317e-01 0.32487273 0.46372670 140.00 6.37367480e-01 6.59845211e-02 6.40773955e-01 0.10315915 0.33799993 140.25 5.93415375e-01 3.51063878e-02 5.94452913e-01 0.05909102 0.26978622 140.50 5.58561943e-01 4.90021397e-02 5.60707280e-01 0.08750507 0.28655387 140.75 4.16720130e-01 -1.01697917e-01 4.28950035e-01 -0.23936491 0.20304828 141.00 3.29769593e-01 -1.83638357e-01 3.77453348e-01 -0.50810137 0.12738982 141.25 2.96231136e-01 -1.80929080e-01 3.47114128e-01 -0.54830098 0.08572758 141.50 2.34663570e-01 -3.07527977e-01 3.86833876e-01 -0.91898647 0.10368950 141.75 1.73101606e-01 -5.01686085e-01 5.30709990e-01 -1.23854732 0.17837808 142.00 -1.96728499e-01 -4.81264712e-01 5.19920980e-01 -1.95884354 0.17381458 142.25 -2.85501242e-01 -4.31522866e-01 5.17419504e-01 -2.15529224 0.18956158 142.50 -3.04264560e-01 -3.55000849e-01 4.67549490e-01 -2.27938707 0.11646189 142.75 -4.30210882e-01 -3.41091258e-01 5.49021538e-01 -2.47122875 0.13174697 143.00 -4.93111888e-01 5.39463546e-02 4.96053972e-01 3.03262616 0.08207798 143.25 -2.64203661e-01 -4.05278403e-02 2.67293996e-01 -2.98938290 0.01777684 143.50 -2.88872816e-01 -3.63967107e-01 4.64671453e-01 -2.24167070 0.02993580 143.75 -4.15176061e-01 -2.77100586e-01 4.99155183e-01 -2.55306240 0.02687776 144.00 7.38652181e-03 3.82091043e-02 3.89165306e-02 1.37983359 0.00015997 144.25 -4.80580734e-02 -2.16777724e-01 2.22040897e-01 -1.78896076 0.00495446 144.50 -4.58212787e-02 -6.14638709e-01 6.16344329e-01 -1.64520862 0.03806238 144.75 2.02689837e-01 -8.49353110e-01 8.73203227e-01 -1.33653744 0.10344317 145.00 1.67130198e+00 -8.76749500e-01 1.88731025e+00 -0.48312610 0.29136601 145.25 2.19604114e+00 -8.46997055e-01 2.35372061e+00 -0.36811199 0.33500134 145.50 2.76761390e+00 -1.33552422e+00 3.07299718e+00 -0.44959397 0.46467333 145.75 3.18011425e+00 -1.95338393e+00 3.73213550e+00 -0.55083132 0.57594046 146.00 3.24308558e+00 -2.31607003e+00 3.98519566e+00 -0.62016379 0.64693868 146.25 3.07706166e+00 -2.03518340e+00 3.68921129e+00 -0.58435093 0.55414104 146.50 2.98673157e+00 -1.43344640e+00 3.31290418e+00 -0.44746970 0.41271629 146.75 1.76775707e+00 -1.49551966e+00 2.31550084e+00 -0.70216634 0.25257733 147.00 1.55632886e+00 -2.04388610e+00 2.56897448e+00 -0.92000375 0.32218373 147.25 1.26080254e+00 -1.38482181e+00 1.87279323e+00 -0.83224100 0.23219724 147.50 9.62118750e-01 -1.62628956e+00 1.88957409e+00 -1.03657353 0.19661973 147.75 1.28030920e+00 -1.61260610e+00 2.05905077e+00 -0.89976270 0.29156825 148.00 1.37454824e+00 -1.28745929e+00 1.88333063e+00 -0.75269431 0.27201479 148.25 2.16078515e+00 -1.18406779e+00 2.46394176e+00 -0.50129129 0.35000260 148.50 2.93374417e+00 -1.72656821e+00 3.40409938e+00 -0.53193583 0.40812458 148.75 3.21717690e+00 -1.70474901e+00 3.64093345e+00 -0.48727249 0.37370579 149.00 3.26945231e+00 -1.23325385e+00 3.49431444e+00 -0.36070244 0.26689380 149.25 2.54068324e+00 6.31279066e-01 2.61793518e+00 0.24353648 0.17493341 149.50 1.92506930e+00 3.16799488e-01 1.95096226e+00 0.16310335 0.13756301 149.75 1.72170315e+00 7.08077215e-01 1.86162162e+00 0.39018019 0.11684632 150.00 1.57828542e+00 7.76654550e-01 1.75902733e+00 0.45729761 0.10955570 150.25 8.50556484e-01 -5.79589795e-01 1.02925734e+00 -0.59814991 0.04574727 150.50 1.02418715e+00 -1.04732876e+00 1.46487435e+00 -0.79656904 0.08451073 150.75 -3.96764170e-01 -8.38124178e-01 9.27293882e-01 -2.01293468 0.04436959 151.00 -4.92723782e-01 -8.96212926e-01 1.02272887e+00 -2.07347391 0.06212588 151.25 -6.39579434e-01 -1.04716404e+00 1.22703479e+00 -2.11909946 0.10549131 151.50 -1.13433540e+00 -9.53322817e-01 1.48173587e+00 -2.44268423 0.14567494 151.75 -1.85204252e-01 -9.95510455e-01 1.01259157e+00 -1.75473299 0.07743525 152.00 -2.42009962e-01 -1.03330149e+00 1.06126377e+00 -1.80085988 0.08175859 152.25 -4.62596368e-01 -8.29621327e-01 9.49877332e-01 -2.07945529 0.06667147 152.50 -4.40640622e-01 -9.67128006e-01 1.06277972e+00 -1.99831209 0.08029182 152.75 -4.69905207e-01 -1.06022031e+00 1.15968875e+00 -1.98799327 0.10749942 153.00 -9.89170743e-01 -1.08465108e+00 1.46796687e+00 -2.31018622 0.20444131 153.25 -9.52161714e-01 -1.27892361e+00 1.59444584e+00 -2.21076968 0.22635377 153.50 -5.96825612e-01 -1.43416065e+00 1.55338906e+00 -1.96514693 0.21295228 153.75 -3.64975752e-01 -1.63628191e+00 1.67649211e+00 -1.79025575 0.21501861 154.00 2.15324614e-02 -1.46102127e+00 1.46117993e+00 -1.55605944 0.20312713 154.25 1.34990983e-01 -1.17065637e+00 1.17841372e+00 -1.45599117 0.13536902 154.50 3.03725792e-01 -1.05154947e+00 1.09453444e+00 -1.28961255 0.09422948 154.75 2.31741943e-01 -2.17738318e+00 2.18968076e+00 -1.46476409 0.23432100 155.00 8.83774069e-01 -1.61764767e+00 1.84332325e+00 -1.07077294 0.14991993 155.25 1.33257464e+00 -1.61309312e+00 2.09232516e+00 -0.88034270 0.15219837 155.50 7.18680099e-01 -1.40146728e+00 1.57499576e+00 -1.09695690 0.10864444 155.75 5.10971362e-01 -8.71860764e-01 1.01056070e+00 -1.04068251 0.04977266 156.00 4.03889275e-01 -5.36140805e-01 6.71247725e-01 -0.92516942 0.02942931 156.25 2.29697989e-01 -1.37496200e+00 1.39401638e+00 -1.40526721 0.08580950 156.50 -1.50341765e-01 -1.73418963e+00 1.74069421e+00 -1.65727292 0.14927616 156.75 -5.23747758e-01 -2.03148206e+00 2.09791112e+00 -1.82311721 0.20423708 157.00 6.82097232e-02 -2.05512638e+00 2.05625801e+00 -1.53761847 0.16827065 157.25 3.17573627e-01 -2.60327546e+00 2.62257433e+00 -1.44940609 0.25929584 157.50 2.52282372e-01 -1.96113180e+00 1.97729217e+00 -1.44285776 0.15066380 157.75 3.26862081e-01 -1.78118581e+00 1.81092841e+00 -1.38930744 0.10860582 158.00 1.31730874e-02 -1.57063025e+00 1.57068549e+00 -1.56240939 0.09731085 158.25 -1.05818003e-01 -1.81264367e+00 1.81572975e+00 -1.62910786 0.12603594 158.50 -3.60537279e-01 -2.74688656e+00 2.77044634e+00 -1.70130337 0.30635086 158.75 -6.09798070e-01 -3.04954119e+00 3.10991240e+00 -1.76815715 0.32933164 159.00 -5.81678546e-01 -3.51477960e+00 3.56258692e+00 -1.73480481 0.33209217 159.25 -2.26590529e-01 -3.99351767e+00 3.99994083e+00 -1.62747514 0.33973837 159.50 -3.76006914e-01 -3.57453537e+00 3.59425713e+00 -1.67560133 0.26359479 159.75 -2.37826814e-01 -3.87177848e+00 3.87907595e+00 -1.63214497 0.26248311 160.00 -5.75000464e-01 -4.00275200e+00 4.04384089e+00 -1.71347155 0.24946235 160.25 -8.06398177e-01 -4.24597872e+00 4.32187613e+00 -1.75848149 0.25815740 160.50 -2.38664983e-01 -4.81093300e+00 4.81684931e+00 -1.62036457 0.35400078 160.75 -4.58465035e-01 -5.09927478e+00 5.11984311e+00 -1.66046313 0.42727979 161.00 -2.78016177e-01 -4.91403920e+00 4.92189742e+00 -1.62731198 0.55942272 161.25 3.68980333e-01 -4.79023224e+00 4.80442207e+00 -1.49392048 0.54553500 161.50 1.69683418e+00 -4.26428939e+00 4.58948911e+00 -1.19208674 0.46358643 161.75 2.16853464e+00 -4.61935474e+00 5.10303642e+00 -1.13188983 0.47139411 162.00 3.69220129e+00 -4.66115916e+00 5.94632282e+00 -0.90087825 0.60454901 162.25 4.46931346e+00 -5.41970978e+00 7.02481437e+00 -0.88121009 0.60562819 162.50 7.24071276e+00 -6.21550276e+00 9.54255709e+00 -0.70935649 0.69825056 162.75 7.40854817e+00 -5.42862692e+00 9.18458361e+00 -0.63237056 0.63415595 163.00 6.21806574e+00 -5.72540795e+00 8.45249298e+00 -0.74417241 0.36471766 163.25 5.14674287e+00 -6.37277556e+00 8.19153408e+00 -0.89142990 0.28130772 163.50 1.59510131e+00 -9.68971652e+00 9.82013006e+00 -1.40764165 0.34944854 163.75 -3.82978951e+00 -1.05403159e+01 1.12145239e+01 -1.91931152 0.48588645 164.00 -6.65449978e+00 -9.08212506e+00 1.12591013e+01 -2.20313510 0.71122545 164.25 -6.48625402e+00 -7.59206865e+00 9.98553943e+00 -2.27780810 0.68484743 164.50 -6.32482490e+00 -6.76309610e+00 9.25974508e+00 -2.32272031 0.64415366 164.75 -5.71379570e+00 -6.03762125e+00 8.31266093e+00 -2.32864516 0.64840613 165.00 -4.71832048e+00 -5.17186885e+00 7.00076964e+00 -2.31036819 0.57385821 165.25 -4.13489106e+00 -3.13663705e+00 5.18997265e+00 -2.49262424 0.38443771 165.50 -3.62192940e+00 -1.72221468e+00 4.01053562e+00 -2.69773931 0.39728272 165.75 -2.63294077e+00 -6.20349420e-01 2.70503429e+00 -2.91020189 0.26546696 166.00 -1.94999308e+00 4.29346353e-01 1.99670011e+00 2.92487219 0.16908436 166.25 -1.24515128e+00 9.61506271e-01 1.57318022e+00 2.48403405 0.18990373 166.50 -6.65896440e-01 7.12345592e-01 9.75117589e-01 2.32250550 0.11945157 166.75 -4.23011651e-01 1.74036948e-01 4.57414163e-01 2.75127736 0.03845565 167.00 -2.96095886e-01 3.35706191e-01 4.47628664e-01 2.29358227 0.05379898 167.25 -2.26133688e-01 -3.62587938e-01 4.27324768e-01 -2.12843563 0.08582445 167.50 -4.94796023e-02 -5.32571349e-01 5.34864911e-01 -1.66343738 0.20847892 167.75 -2.12092943e-02 -6.81280823e-01 6.81610882e-01 -1.60191778 0.25315476 168.00 -7.67521552e-02 -6.59572428e-01 6.64023103e-01 -1.68664184 0.29679011 168.25 1.19025252e-01 -6.83276688e-01 6.93566177e-01 -1.39832919 0.38446434 168.50 1.49309348e-01 -6.45285332e-01 6.62334086e-01 -1.34341292 0.37146275 168.75 3.66695848e-01 -5.45886728e-01 6.57615514e-01 -0.97928724 0.33475618 169.00 5.13478903e-01 -4.26853029e-01 6.67730554e-01 -0.69353479 0.37452586 169.25 6.53560226e-01 -3.39083619e-01 7.36287083e-01 -0.47859422 0.55679209 169.50 6.43198077e-01 -4.08753156e-01 7.62091142e-01 -0.56611513 0.62068656 169.75 6.09708787e-01 -4.00978772e-01 7.29745695e-01 -0.58173863 0.66129306 170.00 6.20109279e-01 -3.98711319e-01 7.37228752e-01 -0.57141694 0.73269109 170.25 6.35379448e-01 -3.94968422e-01 7.48135748e-01 -0.55616943 0.79173519 170.50 6.56103243e-01 -4.23965220e-01 7.81164498e-01 -0.57368988 0.81677856 170.75 7.69911102e-01 -3.56624277e-01 8.48495126e-01 -0.43377822 0.80693037 171.00 8.64658434e-01 -3.53270381e-01 9.34041845e-01 -0.38786932 0.83466879 171.25 1.07359419e+00 -3.88500764e-01 1.14172559e+00 -0.34720942 0.84128547 171.50 1.19442201e+00 -4.90548394e-01 1.29123261e+00 -0.38969583 0.85388041 171.75 1.30690000e+00 -7.42042486e-01 1.50286881e+00 -0.51639758 0.84738904 172.00 1.38020124e+00 -9.44471079e-01 1.67241774e+00 -0.60011084 0.78684602 172.25 8.67632395e-01 -1.78536400e+00 1.98502156e+00 -1.11843601 0.62046715 172.50 4.17405153e-01 -2.16100601e+00 2.20094844e+00 -1.37999285 0.62628689 172.75 -3.16617152e-01 -1.61609383e+00 1.64681684e+00 -1.76426101 0.44731612 173.00 -3.24450366e-01 -1.27899485e+00 1.31950592e+00 -1.81923180 0.46052462 173.25 -2.23371792e-01 -1.10412107e+00 1.12648937e+00 -1.77040949 0.58064827 173.50 -2.83001558e-01 -9.29343692e-01 9.71478039e-01 -1.86639258 0.54242700 173.75 -2.14539134e-01 -7.55225055e-01 7.85106314e-01 -1.84757802 0.52769284 174.00 -2.31311036e-01 -8.39308153e-01 8.70599202e-01 -1.83971773 0.58908720 174.25 -1.71650060e-01 -1.02606664e+00 1.04032519e+00 -1.73655083 0.75512219 174.50 -2.01981789e-01 -9.86382562e-01 1.00685014e+00 -1.77277441 0.73659649 174.75 -4.59159360e-01 -1.09057591e+00 1.18329334e+00 -1.96929502 0.63388705 175.00 -3.18742342e-01 -1.01409699e+00 1.06300959e+00 -1.87533067 0.51088776 175.25 4.58109229e-02 -1.10190602e+00 1.10285789e+00 -1.52924600 0.47379601 175.50 -4.26215050e-02 -1.51221718e+00 1.51281770e+00 -1.59897364 0.45765272 175.75 -8.73063389e-01 -1.08363613e+00 1.39158433e+00 -2.24899078 0.20651082 176.00 -9.56440496e-01 3.27309373e-01 1.01089557e+00 2.81186899 0.23485763 176.25 -8.84324927e-01 4.78972452e-01 1.00570631e+00 2.64520215 0.59292503 176.50 -8.61443753e-01 3.53123721e-01 9.31011118e-01 2.75256322 0.63389533 176.75 -7.94154909e-01 3.10728062e-01 8.52780128e-01 2.76863573 0.60733473 177.00 -8.01603464e-01 4.07924494e-01 8.99427878e-01 2.67086182 0.62055551 177.25 -7.67571891e-01 5.36363316e-01 9.36403874e-01 2.53168645 0.67386555 177.50 -7.23375799e-01 4.17518734e-01 8.35221192e-01 2.61812087 0.67256051 177.75 -7.59341272e-01 4.01082813e-01 8.58758749e-01 2.65564167 0.74743041 178.00 -7.38969401e-01 4.63918296e-01 8.72522757e-01 2.58098889 0.76841700 178.25 -7.48298750e-01 5.10932707e-01 9.06092297e-01 2.54250900 0.83371498 178.50 -6.88799368e-01 4.67209572e-01 8.32303643e-01 2.54558241 0.78961913 178.75 -6.54442737e-01 5.10325117e-01 8.29895789e-01 2.47929958 0.81308703 179.00 -6.48974359e-01 4.94753725e-01 8.16056963e-01 2.49022637 0.85519929 179.25 -6.68569808e-01 4.54659471e-01 8.08517670e-01 2.54438327 0.87735313 179.50 -7.02740156e-01 5.13552607e-01 8.70390721e-01 2.51050239 0.87487367 179.75 -7.37645738e-01 5.48013265e-01 9.18934042e-01 2.50263686 0.88440764 180.00 -7.37263084e-01 6.00075238e-01 9.50603569e-01 2.45841966 0.87753710 180.25 -7.67172009e-01 6.48197408e-01 1.00434694e+00 2.44005639 0.89687242 180.50 -8.04198125e-01 6.84925907e-01 1.05634186e+00 2.43611942 0.88354021 180.75 -7.47082197e-01 7.06450237e-01 1.02820414e+00 2.38414115 0.86910688 181.00 -7.69383940e-01 6.83010162e-01 1.02881219e+00 2.41559446 0.82358701 181.25 -7.74486769e-01 6.83417350e-01 1.03290320e+00 2.41857942 0.82919607 181.50 -7.44386804e-01 6.60778842e-01 9.95359428e-01 2.41562485 0.71416546 181.75 -6.93549469e-01 6.32886331e-01 9.38912122e-01 2.40189659 0.67567137 182.00 -6.81938641e-01 6.06871180e-01 9.12870713e-01 2.41437433 0.68847311 182.25 -5.90218237e-01 5.19264225e-01 7.86125246e-01 2.42005987 0.63145676 182.50 -7.21608391e-01 2.99623535e-01 7.81340472e-01 2.74803802 0.51307972 182.75 -7.73325608e-01 1.17369523e-01 7.82181629e-01 2.99096971 0.46956459 183.00 -6.98168708e-01 -5.70418819e-02 7.00495054e-01 -3.06007158 0.37219086 183.25 -6.55460206e-01 -4.17267583e-02 6.56787031e-01 -3.07801820 0.25455110 183.50 -5.09709862e-01 -2.58254579e-01 5.71401409e-01 -2.67262348 0.10016846 183.75 -3.06023973e-01 -5.48489869e-01 6.28085829e-01 -2.07971442 0.10119743 184.00 -1.18689304e-01 -1.06691554e+00 1.07349705e+00 -1.68158607 0.26871930 184.25 2.99265010e-01 -1.17417537e+00 1.21171257e+00 -1.32123707 0.30308137 184.50 1.18617313e+00 -1.48288351e+00 1.89893396e+00 -0.89611035 0.53193786 184.75 1.56332688e+00 -1.28647187e+00 2.02459892e+00 -0.68855310 0.63284820 185.00 2.07979954e+00 -1.07820851e+00 2.34266936e+00 -0.47827434 0.75151474 185.25 1.93552496e+00 -9.81326031e-01 2.17008241e+00 -0.46923803 0.79605162 185.50 1.90577442e+00 -1.06500564e+00 2.18316586e+00 -0.50959788 0.89331534 185.75 1.70517722e+00 -8.67337306e-01 1.91308739e+00 -0.47054313 0.89428625 186.00 1.59180529e+00 -7.37990323e-01 1.75455801e+00 -0.43412115 0.92752884 186.25 1.43300511e+00 -7.16421482e-01 1.60211216e+00 -0.46360235 0.91742300 186.50 1.28580994e+00 -6.96898786e-01 1.46252354e+00 -0.49667430 0.93682633 186.75 1.17797391e+00 -6.41838838e-01 1.34148412e+00 -0.49889361 0.93948499 187.00 1.06707441e+00 -6.52150500e-01 1.25057909e+00 -0.54858316 0.94013231 187.25 8.64858468e-01 -6.57753901e-01 1.08656356e+00 -0.65020858 0.88184153 187.50 6.20292336e-01 -6.09789428e-01 8.69830862e-01 -0.77685999 0.88353800 187.75 4.71213747e-01 -4.81082837e-01 6.73411532e-01 -0.79576126 0.82561804 188.00 4.17072746e-01 -3.31096104e-01 5.32516953e-01 -0.67098395 0.84900294 188.25 3.76609897e-01 -2.53646983e-01 4.54061457e-01 -0.59271886 0.71652175 188.50 3.43991281e-01 -1.15801191e-01 3.62959939e-01 -0.32472351 0.57013423 188.75 3.32709824e-01 1.37017360e-02 3.32991839e-01 0.04115898 0.42014133 189.00 3.17075132e-01 1.06724661e-01 3.34554619e-01 0.32467965 0.46451991 189.25 4.06148063e-01 1.77300302e-01 4.43160970e-01 0.41160527 0.63163141 189.50 4.54633288e-01 2.08470973e-01 5.00151550e-01 0.42993928 0.72721005 189.75 5.01559048e-01 2.05700678e-01 5.42101695e-01 0.38920214 0.72489227 190.00 5.21243532e-01 1.84230205e-01 5.52843185e-01 0.33973934 0.78923264 190.25 5.62087325e-01 1.15858549e-01 5.73903619e-01 0.20327508 0.81540416 190.50 5.80708206e-01 1.07558133e-01 5.90585110e-01 0.18314341 0.85711837 190.75 5.69221956e-01 1.60458773e-01 5.91405659e-01 0.27476173 0.82649790 191.00 5.77944739e-01 1.48601231e-01 5.96743200e-01 0.25166866 0.85026603 191.25 6.12874757e-01 1.01577775e-01 6.21235472e-01 0.16424678 0.87020783 191.50 6.31307982e-01 8.15846893e-02 6.36557798e-01 0.12851891 0.87398865 191.75 6.33893294e-01 5.03812403e-02 6.35892268e-01 0.07931233 0.88314114 192.00 6.59912015e-01 -7.05577184e-03 6.59949734e-01 -0.01069158 0.88562180 192.25 6.96930582e-01 -8.13178253e-02 7.01658624e-01 -0.11615473 0.90509570 192.50 7.14772254e-01 -1.19973025e-01 7.24770931e-01 -0.16629777 0.91538938 192.75 6.86553425e-01 -1.85240236e-01 7.11104458e-01 -0.26353644 0.91202622 193.00 6.58209596e-01 -2.19022687e-01 6.93693599e-01 -0.32123017 0.91017553 193.25 6.73735176e-01 -2.80951771e-01 7.29967797e-01 -0.39508042 0.90409473 193.50 6.53627690e-01 -3.40346566e-01 7.36929401e-01 -0.48007330 0.88759438 193.75 6.07209368e-01 -4.46020954e-01 7.53417486e-01 -0.63353455 0.89681726 194.00 5.18330087e-01 -5.16731607e-01 7.31900016e-01 -0.78385383 0.87200984 194.25 4.28279044e-01 -6.18636981e-01 7.52419200e-01 -0.96526051 0.88327084 194.50 3.95621380e-01 -6.44432342e-01 7.56180745e-01 -1.02021396 0.85830467 194.75 3.06501643e-01 -7.33520873e-01 7.94981842e-01 -1.17499741 0.86377848 195.00 2.01698718e-01 -8.17432831e-01 8.41949409e-01 -1.32888209 0.86396579 195.25 -3.28672702e-02 -8.97956261e-01 8.98557568e-01 -1.60738230 0.88341209 195.50 -1.72160526e-01 -8.87585997e-01 9.04128392e-01 -1.76238223 0.86496073 195.75 -3.97061785e-01 -8.12112765e-01 9.03982966e-01 -2.02554430 0.82769246 196.00 -5.71297546e-01 -6.95469840e-01 9.00032879e-01 -2.25848368 0.72549930 196.25 -7.26402057e-01 -4.03854197e-01 8.31118620e-01 -2.63418124 0.58458454 196.50 -5.25742720e-01 -1.07136549e-01 5.36547899e-01 -2.94056386 0.57323024 196.75 -5.49450642e-01 -8.03689744e-02 5.55297380e-01 -2.99635113 0.88214874 197.00 -6.02273220e-01 -3.55612685e-02 6.03322165e-01 -3.08261605 0.78091537 197.25 -7.93308802e-01 -6.00431726e-02 7.95577801e-01 -3.06604967 0.56989905 197.50 -3.94669179e-01 -5.45440971e-01 6.73253009e-01 -2.19717192 0.55456007 197.75 -2.46587694e-01 -6.19563772e-01 6.66831882e-01 -1.94957921 0.88082143 198.00 -2.76375651e-01 -5.18936065e-01 5.87943994e-01 -2.06016799 0.91667409 198.25 -3.19474106e-01 -4.56838660e-01 5.57463242e-01 -2.18106238 0.95341916 198.50 -3.74087943e-01 -4.33582425e-01 5.72656536e-01 -2.28266545 0.93462128 198.75 -4.49403280e-01 -4.32156481e-01 6.23476168e-01 -2.37575595 0.94705707 199.00 -5.55404079e-01 -4.10658444e-01 6.90734427e-01 -2.50491867 0.92375667 199.25 -6.59164392e-01 -3.68217797e-01 7.55037775e-01 -2.63216083 0.92984518 199.50 -7.13010045e-01 -2.43244629e-01 7.53359989e-01 -2.81282210 0.87572646 199.75 -7.07014758e-01 -1.59807419e-01 7.24850522e-01 -2.91929688 0.85125465 200.00 -7.24443623e-01 -1.14430770e-01 7.33425500e-01 -2.98493026 0.82603002 200.25 -8.61681660e-01 -1.34815241e-01 8.72164223e-01 -2.98639486 0.90568405 200.50 -9.92315459e-01 -1.01114940e-01 9.97453859e-01 -3.04004517 0.87358861 200.75 -1.11751903e+00 3.12116077e-02 1.11795481e+00 3.11367054 0.85373296 201.00 -1.08997924e+00 3.63971697e-01 1.14914322e+00 2.81930938 0.81504765 201.25 -1.00840536e+00 5.42491055e-01 1.14506678e+00 2.64803302 0.82194114 201.50 -8.59383340e-01 6.34118474e-01 1.06801028e+00 2.50589607 0.80752383 201.75 -8.07849889e-01 7.27195731e-01 1.08693839e+00 2.40868808 0.80774191 202.00 -6.74604562e-01 7.75701786e-01 1.02801001e+00 2.28659957 0.77548834 202.25 -6.34634959e-01 8.49071080e-01 1.06003926e+00 2.21266100 0.78273525 202.50 -5.07893711e-01 9.10923848e-01 1.04294692e+00 2.07942440 0.79412913 202.75 -4.26977308e-01 8.57271652e-01 9.57718281e-01 2.03289502 0.75829935 203.00 -2.24460867e-01 6.66174761e-01 7.02973323e-01 1.89578928 0.58102392 203.25 -2.01652696e-01 6.73263196e-01 7.02813731e-01 1.86180848 0.61789616 203.50 -1.87991840e-01 6.03903841e-01 6.32487772e-01 1.87258241 0.59778834 203.75 -1.80279981e-01 6.34483127e-01 6.59598143e-01 1.84763691 0.58905066 204.00 -7.54544123e-02 5.11659210e-01 5.17192919e-01 1.71721109 0.42275610 204.25 -9.82146956e-02 4.34845140e-01 4.45798634e-01 1.79293043 0.35205088 204.50 1.19473279e-01 3.76413178e-01 3.94918656e-01 1.26345429 0.30720409 204.75 8.83468477e-02 2.91576942e-01 3.04667489e-01 1.27659255 0.21178304 205.00 4.80268648e-03 2.51353162e-01 2.51399041e-01 1.55169133 0.19174265 205.25 -3.85952987e-02 1.33935207e-01 1.39385210e-01 1.85135930 0.06913737 205.50 -7.18690480e-02 8.08567902e-03 7.23224604e-02 3.02955804 0.02815673 205.75 -1.38262794e-01 4.50639944e-03 1.38336213e-01 3.10901119 0.08116278 206.00 -2.87059650e-01 1.29684102e-01 3.14993983e-01 2.71727019 0.26872471 206.25 -2.79256125e-01 1.49011896e-01 3.16525715e-01 2.65142543 0.24312266 206.50 -3.38009297e-01 2.27137485e-01 4.07236690e-01 2.54991653 0.34297767 206.75 -4.06338089e-01 2.96190302e-01 5.02831322e-01 2.51171604 0.38169472 207.00 -3.62115389e-01 4.77934885e-01 5.99624307e-01 2.21918615 0.46161219 207.25 -2.78653471e-01 4.76269357e-01 5.51797297e-01 2.10016955 0.41509647 207.50 -2.91811246e-01 3.18485628e-01 4.31957057e-01 2.31251507 0.32246573 207.75 -1.78161646e-01 2.21898110e-01 2.84570454e-01 2.24730211 0.11709719 208.00 -1.05344158e-01 2.88425919e-01 3.07061724e-01 1.92098135 0.10854415 208.25 7.95981445e-03 1.61566280e-01 1.61762237e-01 1.52156957 0.04117709 208.50 -6.21938976e-02 -3.82833713e-03 6.23116126e-02 -3.08011535 0.00679355 208.75 -3.52360592e-01 -1.66509872e-01 3.89722368e-01 -2.70014085 0.15187745 209.00 -5.14132875e-01 -2.56649285e-01 5.74631594e-01 -2.67859435 0.29149563 209.25 -7.29736679e-01 -3.97844958e-01 8.31141523e-01 -2.64245003 0.31432467 209.50 -1.29300459e+00 -5.38664481e-01 1.40072135e+00 -2.74685915 0.43760133 209.75 -1.21681289e+00 -7.66921155e-01 1.43833294e+00 -2.57921236 0.30276612 210.00 -1.01918076e+00 -1.48824068e+00 1.80377098e+00 -2.17126328 0.20524525 210.25 4.52479432e-01 5.22322105e-01 6.91055727e-01 0.85692403 0.01535496 210.50 1.08923916e+00 3.55680940e+00 3.71985686e+00 1.27362416 0.25449274 210.75 2.51089396e+00 4.28692636e+00 4.96813105e+00 1.04095074 0.41436798 211.00 3.94397790e+00 4.86699558e+00 6.26439204e+00 0.88977520 0.56506971 211.25 5.06833987e+00 2.64253740e+00 5.71586152e+00 0.48060594 0.64481115 211.50 5.12536057e+00 1.20583639e+00 5.26529794e+00 0.23106649 0.67335746 211.75 3.33535935e+00 -8.46473603e-01 3.44109569e+00 -0.24854049 0.63377138 212.00 2.85951443e+00 -1.09891352e+00 3.06340231e+00 -0.36689971 0.69256162 212.25 1.94136102e+00 -9.08370918e-01 2.14336659e+00 -0.43764288 0.67958043 212.50 1.61864676e+00 -9.00275442e-01 1.85216447e+00 -0.50758333 0.64522246 212.75 1.06802722e+00 -6.52355137e-01 1.25149885e+00 -0.54832566 0.57343656 213.00 9.34558105e-01 -5.30649209e-01 1.07470342e+00 -0.51641221 0.58321931 213.25 5.94609243e-01 -4.71689404e-01 7.58980267e-01 -0.67062764 0.53845555 213.50 5.28605933e-01 -3.42305283e-01 6.29759588e-01 -0.57465965 0.49753545 213.75 4.75742099e-01 -1.24314314e-01 4.91715968e-01 -0.25559107 0.53660179 214.00 4.61927675e-01 -4.80351557e-02 4.64418511e-01 -0.10361606 0.56547002 214.25 3.65521922e-01 1.65268499e-01 4.01148292e-01 0.42463534 0.46091217 214.50 3.23575213e-01 3.63933872e-01 4.86979241e-01 0.84403360 0.46057772 214.75 3.21281312e-01 6.98115961e-01 7.68496959e-01 1.13948266 0.65602982 215.00 3.62444830e-01 8.14526275e-01 8.91526392e-01 1.15212802 0.66410435 215.25 4.95438955e-01 1.02635882e+00 1.13968074e+00 1.12107197 0.58673287 215.50 6.16118313e-01 8.54293995e-01 1.05329009e+00 0.94598228 0.34195399 215.75 7.49544695e-01 6.33151355e-02 7.52214103e-01 0.08427140 0.09557846 216.00 7.07406228e-01 -3.92653660e-01 8.09073834e-01 -0.50672057 0.15632527 216.25 4.02063330e-01 -6.21476034e-01 7.40194151e-01 -0.99656888 0.19990423 216.50 3.48346853e-01 -5.27683749e-01 6.32293973e-01 -0.98732356 0.23936361 216.75 2.65772356e-01 -5.24771503e-01 5.88234711e-01 -1.10199927 0.34733130 217.00 3.37790751e-01 -3.02003943e-01 4.53110332e-01 -0.72952156 0.31387039 217.25 5.17653984e-01 -1.13822291e-01 5.30019963e-01 -0.21643682 0.50005669 217.50 9.00456323e-01 -8.07647190e-02 9.04071086e-01 -0.08945373 0.71355142 217.75 1.12871769e+00 -1.39923484e-01 1.13735756e+00 -0.12333753 0.88661440 218.00 1.13383215e+00 -3.06270422e-01 1.17446878e+00 -0.26382342 0.84601958 218.25 1.04620742e+00 -4.63391239e-01 1.14423835e+00 -0.41695466 0.82991340 218.50 9.95716745e-01 -5.53381728e-01 1.13915898e+00 -0.50725640 0.82099398 218.75 9.38985909e-01 -6.14882262e-01 1.12239687e+00 -0.57976772 0.83703539 219.00 8.43053744e-01 -6.35580648e-01 1.05579467e+00 -0.64599428 0.79260565 219.25 7.49534444e-01 -6.35710343e-01 9.82817136e-01 -0.70341340 0.81784797 219.50 6.25853999e-01 -6.82414736e-01 9.25949836e-01 -0.82860453 0.73606215 219.75 6.03420141e-01 -7.27233580e-01 9.44978596e-01 -0.87817810 0.66736488 220.00 5.15328483e-01 -6.13931092e-01 8.01545277e-01 -0.87249343 0.55484714 220.25 5.66569982e-01 -5.63229150e-01 7.98892120e-01 -0.78244116 0.49035877 220.50 1.04822061e+00 -7.85874282e-01 1.31010108e+00 -0.64332330 0.61991470 220.75 1.34580698e+00 -1.10359759e+00 1.74043789e+00 -0.68683358 0.79724513 221.00 1.23381348e+00 -1.50582214e+00 1.94673985e+00 -0.88436027 0.76671910 221.25 1.34565750e+00 -1.80364004e+00 2.25031365e+00 -0.92980955 0.79862553 221.50 8.71103659e-01 -2.13818974e+00 2.30882588e+00 -1.18392489 0.75416900 221.75 5.75714843e-01 -2.45477614e+00 2.52138325e+00 -1.34043129 0.82038697 222.00 2.08771429e-01 -2.75961969e+00 2.76750544e+00 -1.49528791 0.82233822 222.25 -2.29540323e-01 -3.16228005e+00 3.17059993e+00 -1.64325621 0.82913414 222.50 -1.43271817e+00 -3.62885297e+00 3.90144271e+00 -1.94682313 0.80807637 222.75 -2.32408721e+00 -3.39331388e+00 4.11290171e+00 -2.17131732 0.80884682 223.00 -3.58683256e+00 -1.50097491e+00 3.88822498e+00 -2.74526759 0.76774983 223.25 -3.97204356e+00 -4.01400215e-01 3.99227406e+00 -3.04087822 0.80393659 223.50 -3.13835952e+00 6.96540826e-01 3.21472699e+00 2.92318862 0.72593720 223.75 -2.39405623e+00 9.43566838e-01 2.57329043e+00 2.76615776 0.72190121 224.00 -1.56032885e+00 1.12806250e+00 1.92539636e+00 2.51561991 0.68560544 224.25 -1.19111960e+00 1.12970501e+00 1.64164531e+00 2.38265071 0.66480510 224.50 -7.78293009e-01 1.04840251e+00 1.30571353e+00 2.20939044 0.67302738 224.75 -6.13155075e-01 9.24698087e-01 1.10951597e+00 2.15631645 0.62955005 225.00 -2.87876080e-01 6.55822844e-01 7.16223597e-01 1.98442655 0.57709989 225.25 -2.46526918e-01 5.17472942e-01 5.73196098e-01 2.01539074 0.47716080 225.50 -2.73157793e-01 4.00457479e-01 4.84748772e-01 2.16941737 0.44757100 225.75 -2.85605824e-01 2.80355274e-01 4.00212151e-01 2.36547145 0.40901873 226.00 -2.38647814e-01 1.40712832e-01 2.77043102e-01 2.60883640 0.37891535 226.25 -1.99293426e-01 9.37297709e-02 2.20234283e-01 2.70197756 0.28335653 226.50 -2.55567814e-01 -2.02177817e-02 2.56366273e-01 -3.06264780 0.39099895 226.75 -2.99356144e-01 -6.86725936e-02 3.07131936e-01 -2.91609326 0.44615428 227.00 -3.11573192e-01 -9.14493613e-02 3.24716553e-01 -2.85610201 0.50974746 227.25 -4.00286123e-01 -1.80843561e-01 4.39241817e-01 -2.71725470 0.54681231 227.50 -5.62166001e-01 -2.60603897e-01 6.19632959e-01 -2.70751051 0.76400399 227.75 -6.26733719e-01 -2.76899361e-01 6.85177649e-01 -2.72556752 0.67625667 228.00 -8.36523353e-01 -2.86373028e-01 8.84183709e-01 -2.81176066 0.75708909 228.25 -8.50756023e-01 -2.25106099e-01 8.80033276e-01 -2.88292505 0.70549895 228.50 -9.37400837e-01 -1.51559771e-01 9.49573954e-01 -2.98129892 0.81759273 228.75 -9.51544851e-01 -2.62916240e-02 9.51908006e-01 -3.11396922 0.77318425 229.00 -9.40160508e-01 9.20545709e-02 9.44656458e-01 3.04399009 0.78730840 229.25 -8.90652866e-01 1.73832657e-01 9.07458164e-01 2.94884135 0.74774393 229.50 -8.97679868e-01 1.75636715e-01 9.14700716e-01 2.94837720 0.77661013 229.75 -9.56079315e-01 1.31636878e-01 9.65098919e-01 3.00476885 0.76658121 230.00 -1.01207423e+00 1.46411280e-01 1.02260966e+00 2.99792477 0.81846845 230.25 -9.38058166e-01 2.46969500e-01 9.70024256e-01 2.88415719 0.76047261 230.50 -9.79644165e-01 2.65347867e-01 1.01494442e+00 2.87707805 0.77880798 230.75 -9.65093889e-01 2.95311095e-01 1.00926451e+00 2.84464764 0.70872018 231.00 -8.69924068e-01 3.83313242e-01 9.50629752e-01 2.72655943 0.68618027 231.25 -8.73054151e-01 3.45545172e-01 9.38948890e-01 2.76472177 0.61382058 231.50 -9.89794989e-01 3.71633889e-01 1.05726339e+00 2.78241392 0.67719401 231.75 -9.28498916e-01 4.81896528e-01 1.04610444e+00 2.66285609 0.65144652 232.00 -9.17733357e-01 4.67339022e-01 1.02987391e+00 2.67058690 0.65708507 232.25 -8.88826598e-01 5.16786855e-01 1.02814463e+00 2.61494251 0.58482114 232.50 -8.85990678e-01 4.84501425e-01 1.00981241e+00 2.64117332 0.54691939 232.75 -9.38796527e-01 3.94437518e-01 1.01829263e+00 2.74383521 0.47875188 233.00 -9.98983828e-01 5.51049413e-01 1.14088744e+00 2.63751424 0.49425181 233.25 -6.25304209e-01 6.93970364e-01 9.34130729e-01 2.30419300 0.34028066 233.50 -6.73135608e-01 6.00139755e-01 9.01819977e-01 2.41346100 0.33460606 233.75 -1.01926606e+00 6.89450802e-01 1.23054691e+00 2.54686887 0.38325505 234.00 -1.13397360e+00 7.74165970e-01 1.37303644e+00 2.54257071 0.37435871 234.25 -1.06053639e+00 1.05785541e+00 1.49793041e+00 2.35746006 0.31912243 234.50 -9.09231399e-01 1.16363019e+00 1.47673185e+00 2.23407686 0.27702093 234.75 -5.31265431e-01 9.76181473e-01 1.11138347e+00 2.06919737 0.13222486 235.00 -4.84676014e-01 7.50489945e-01 8.93390170e-01 2.14422236 0.07359460 235.25 -5.61235764e-01 1.01896457e+00 1.16330322e+00 2.07424606 0.14133249 235.50 -5.73964581e-01 9.65639354e-01 1.12334087e+00 2.10707924 0.13841186 235.75 -8.32632389e-01 7.17234052e-01 1.09895468e+00 2.43051431 0.15660936 236.00 -1.15844514e+00 9.20265719e-01 1.47948780e+00 2.47027733 0.24231316 236.25 -1.42478857e+00 1.67826789e+00 2.20150075e+00 2.27468848 0.40793786 236.50 -1.15739195e+00 2.24665122e+00 2.52725105e+00 2.04650075 0.42287680 236.75 -1.67405561e-01 2.68386374e+00 2.68907962e+00 1.63309046 0.49529171 237.00 1.19149974e-01 2.17319058e+00 2.17645446e+00 1.51602396 0.45333550 237.25 4.28325047e-01 1.65154520e+00 1.70618402e+00 1.31703902 0.42571647 237.50 6.58991419e-01 1.39994287e+00 1.54729110e+00 1.13083985 0.39691963 237.75 8.29529208e-01 1.04438985e+00 1.33374243e+00 0.89955808 0.42153072 238.00 3.91707636e-01 7.90382835e-01 8.82122382e-01 1.11068110 0.35041026 238.25 1.19004393e-01 7.68403363e-01 7.77563999e-01 1.41714474 0.46977152 238.50 1.35585070e-02 8.78401123e-01 8.78505758e-01 1.55536211 0.50771281 238.75 1.25556974e-01 1.03875064e+00 1.04631135e+00 1.45050682 0.63252461 239.00 2.33526995e-01 1.15693707e+00 1.18027041e+00 1.37162318 0.70082231 239.25 4.89661350e-01 1.22718640e+00 1.32127011e+00 1.19114249 0.71527839 239.50 4.30644467e-01 1.08730918e+00 1.16948532e+00 1.19368730 0.62709483 239.75 2.87055924e-01 9.72807613e-01 1.01427598e+00 1.28385952 0.59705219 240.00 2.43779511e-01 9.36053134e-01 9.67276548e-01 1.31602234 0.54460790 240.25 3.41581917e-01 9.56939825e-01 1.01607679e+00 1.22794136 0.63717755 240.50 2.36452601e-01 1.07251811e+00 1.09827362e+00 1.35380263 0.64237304 240.75 3.52832328e-01 1.25208060e+00 1.30084452e+00 1.29612221 0.76455413 241.00 5.59072094e-01 1.27833544e+00 1.39524302e+00 1.15851699 0.73552166 241.25 6.28225177e-01 1.20507563e+00 1.35899748e+00 1.09024172 0.79203250 241.50 7.73538775e-01 9.41997603e-01 1.21890185e+00 0.88328037 0.76624468 241.75 8.84743698e-01 7.98650207e-01 1.19189495e+00 0.73429988 0.80909464 242.00 7.55112082e-01 5.95453436e-01 9.61643931e-01 0.66772814 0.77433377 242.25 6.99241582e-01 4.91123731e-01 8.54483065e-01 0.61231233 0.80785415 242.50 5.48806571e-01 4.03471592e-01 6.81159289e-01 0.63394862 0.75514273 242.75 4.38928493e-01 3.67672265e-01 5.72574114e-01 0.69728552 0.73906383 243.00 3.19996634e-01 3.99632420e-01 5.11960854e-01 0.89561200 0.69234826 243.25 2.65822134e-01 3.96900793e-01 4.77694093e-01 0.98066592 0.65192699 243.50 3.47449834e-02 2.97930596e-01 2.99949752e-01 1.45469969 0.18049163 243.75 -4.35484648e-02 3.94786511e-01 3.97181140e-01 1.68066105 0.19202989 244.00 4.04178155e-01 3.84930245e-01 5.58149867e-01 0.76101103 0.20336589 244.25 5.55800272e-01 3.96183242e-01 6.82550440e-01 0.61927552 0.32944774 244.50 6.80538149e-01 3.81162918e-01 7.80011117e-01 0.51055718 0.48294348 244.75 6.90441731e-01 2.98519401e-01 7.52212481e-01 0.40808810 0.51007048 245.00 5.94486087e-01 1.64740418e-01 6.16889871e-01 0.27033052 0.57338631 245.25 5.42462560e-01 1.65784767e-01 5.67230304e-01 0.29660030 0.55926009 245.50 3.55187451e-01 1.69769084e-01 3.93674570e-01 0.44586911 0.43424991 245.75 3.40957719e-01 1.98837458e-01 3.94700520e-01 0.52795508 0.46011809 246.00 3.17218937e-01 2.32123305e-01 3.93076434e-01 0.63171504 0.51881944 246.25 3.00790150e-01 2.42485583e-01 3.86359900e-01 0.67848697 0.52963716 246.50 2.52962477e-01 2.36506492e-01 3.46302376e-01 0.75179074 0.55805497 246.75 2.46620429e-01 2.33550012e-01 3.39657539e-01 0.75818451 0.52477724 247.00 2.50416768e-01 2.74115874e-01 3.71278966e-01 0.83054883 0.61876871 247.25 2.47435581e-01 2.91900144e-01 3.82661810e-01 0.86765534 0.67355646 247.50 2.70632009e-01 3.02486168e-01 4.05881222e-01 0.84092147 0.75493950 247.75 2.66415902e-01 2.85063063e-01 3.90177373e-01 0.81919829 0.75539629 248.00 2.22614356e-01 2.62594411e-01 3.44257137e-01 0.86761008 0.84505495 248.25 1.86854192e-01 2.51781852e-01 3.13542007e-01 0.93235280 0.78065346 248.50 1.42079787e-01 2.64618890e-01 3.00349502e-01 1.07804898 0.76752241 248.75 9.01690551e-02 2.65943119e-01 2.80813463e-01 1.24390612 0.65926584 249.00 1.01410542e-02 2.98238361e-01 2.98410725e-01 1.53680624 0.66745418 249.25 -2.25020596e-02 3.37221468e-01 3.37971391e-01 1.63742539 0.58206255 249.50 -1.50631107e-01 3.71555932e-01 4.00928349e-01 1.95595458 0.44871849 249.75 -1.04910099e-01 2.82902427e-01 3.01728209e-01 1.92591043 0.04210265 250.00 4.03044411e-02 7.05624509e-02 8.12619680e-02 1.05183142 0.00124857 250.25 -3.67340543e-02 5.09822968e-01 5.11144646e-01 1.64272459 0.07474661 250.50 3.34995216e-01 7.86825544e-01 8.55170294e-01 1.16828603 0.35676174 250.75 5.65008413e-01 5.78326075e-01 8.08514413e-01 0.79704573 0.46822207 251.00 6.70402606e-01 4.98344622e-01 8.35336469e-01 0.63923232 0.64609007 251.25 6.20733107e-01 3.74800563e-01 7.25110372e-01 0.54321119 0.64544646 251.50 6.66172166e-01 3.51112047e-01 7.53037200e-01 0.48505976 0.76556487 251.75 5.47495013e-01 2.71417393e-01 6.11079529e-01 0.46023705 0.73483560 252.00 5.31713751e-01 3.15070831e-01 6.18052701e-01 0.53492891 0.73250269 252.25 5.13473692e-01 2.85050984e-01 5.87289789e-01 0.50678268 0.79291172 252.50 5.28049100e-01 2.86125965e-01 6.00586313e-01 0.49656824 0.84483835 252.75 5.56438745e-01 2.59128902e-01 6.13817452e-01 0.43582624 0.83889859 253.00 5.46151588e-01 2.25167759e-01 5.90747050e-01 0.39104815 0.85480592 253.25 4.93026230e-01 1.95539568e-01 5.30387204e-01 0.37758131 0.79167855 253.50 4.65795171e-01 2.08378945e-01 5.10281223e-01 0.42065779 0.78254014 253.75 4.60229389e-01 2.21671190e-01 5.10831877e-01 0.44886315 0.79866853 254.00 4.62923109e-01 2.07060129e-01 5.07120993e-01 0.42059666 0.83634678 254.25 4.68569448e-01 2.21495075e-01 5.18283124e-01 0.44157408 0.74290263 254.50 4.60807014e-01 1.90472633e-01 4.98621027e-01 0.39195815 0.75308784 254.75 4.01203791e-01 2.03926617e-01 4.50056160e-01 0.47025510 0.69484875 255.00 3.30052423e-01 2.52487202e-01 4.15553112e-01 0.65302665 0.63756024 255.25 3.41028005e-01 3.77057519e-01 5.08401881e-01 0.83553053 0.73488724 255.50 3.95591480e-01 3.99263182e-01 5.62053119e-01 0.79001747 0.78007951 255.75 5.36792790e-01 4.11145427e-01 6.76156092e-01 0.65361828 0.81446044 256.00 5.68767190e-01 3.35591164e-01 6.60391964e-01 0.53305827 0.76833854 256.25 5.94485418e-01 1.60984462e-01 6.15896833e-01 0.26445390 0.70457307 256.50 5.83576786e-01 1.09318891e-01 5.93727619e-01 0.18517950 0.76071233 256.75 6.09877956e-01 2.06702110e-02 6.10228136e-01 0.03387940 0.82062004 257.00 5.80412766e-01 -2.14545239e-02 5.80809156e-01 -0.03694743 0.79129849 257.25 5.34335258e-01 -4.01329894e-02 5.35840298e-01 -0.07496750 0.75479782 257.50 4.79629221e-01 -3.84646143e-02 4.81169114e-01 -0.08002529 0.72972388 257.75 4.08671087e-01 -7.33929422e-02 4.15209081e-01 -0.17769507 0.73108831 258.00 3.18272035e-01 -7.20132999e-02 3.26317336e-01 -0.22251660 0.63666355 258.25 2.69554518e-01 -9.36816435e-02 2.85369740e-01 -0.33448381 0.65596453 258.50 2.69888524e-01 -7.12891327e-02 2.79145044e-01 -0.25824468 0.62338145 258.75 2.44908023e-01 -7.10068337e-02 2.54993941e-01 -0.28219530 0.69485272 259.00 2.30410870e-01 -4.62736771e-02 2.35011536e-01 -0.19819460 0.64053500 259.25 1.65125735e-01 -7.00205274e-03 1.65274127e-01 -0.04237898 0.60039539 259.50 1.52134154e-01 4.59884684e-02 1.58933131e-01 0.29355539 0.51388747 259.75 1.59962336e-01 1.07977175e-01 1.92994869e-01 0.59376082 0.66947800 260.00 1.85439081e-01 1.31122599e-01 2.27114043e-01 0.61547024 0.64552398 260.25 2.40862805e-01 1.43786605e-01 2.80516450e-01 0.53818471 0.70612813 260.50 2.81162684e-01 1.36589367e-01 3.12584565e-01 0.45222475 0.75482565 260.75 3.20794236e-01 1.15265997e-01 3.40874158e-01 0.34494853 0.82929910 261.00 3.46215178e-01 6.38065014e-02 3.52045763e-01 0.18225218 0.77642778 261.25 3.49486118e-01 5.58108242e-03 3.49530678e-01 0.01596804 0.82323250 261.50 3.32214292e-01 -2.94244337e-02 3.33514817e-01 -0.08834012 0.80216043 261.75 3.11277428e-01 -5.20610326e-02 3.15600995e-01 -0.16571582 0.80108928 262.00 2.53113173e-01 -3.47272010e-02 2.55484358e-01 -0.13634900 0.61831202 262.25 2.28019776e-01 -1.76189514e-02 2.28699466e-01 -0.07711617 0.57038127 262.50 1.80642269e-01 -4.35319222e-02 1.85813502e-01 -0.23647532 0.36157148 262.75 1.42655533e-01 -5.34313595e-02 1.52333552e-01 -0.35837443 0.26129549 263.00 1.17259940e-01 -1.40250696e-02 1.18095707e-01 -0.11904115 0.13067083 263.25 1.23544861e-01 3.26677392e-02 1.27790899e-01 0.25850376 0.14413671 263.50 1.48033228e-01 1.63334553e-01 2.20435960e-01 0.83450095 0.23815157 263.75 2.30323261e-01 2.62948852e-01 3.49558154e-01 0.85144313 0.39856107 264.00 3.00609904e-01 4.23544019e-01 5.19380256e-01 0.95355739 0.55442761 264.25 3.00961261e-01 3.90142695e-01 4.92736241e-01 0.91373097 0.55759103 264.50 2.37907908e-01 2.71770451e-01 3.61191571e-01 0.85173971 0.31249746 264.75 8.86280014e-02 2.06926813e-01 2.25108037e-01 1.16612878 0.17686458 265.00 4.55181809e-02 1.50644211e-01 1.57370846e-01 1.27736194 0.10485258 265.25 6.11300891e-02 1.46963166e-01 1.59169909e-01 1.17661160 0.14288191 265.50 2.80652505e-02 1.31558928e-01 1.34519180e-01 1.36061850 0.12319338 265.75 6.80756584e-02 1.16600479e-01 1.35018395e-01 1.04234627 0.13112275 266.00 3.22873121e-03 8.46261680e-02 8.46877382e-02 1.53266195 0.09087447 266.25 1.13905809e-02 6.24266313e-02 6.34573056e-02 1.39031824 0.06075786 266.50 4.81664993e-02 8.90150785e-02 1.01211145e-01 1.07480797 0.15976256 266.75 4.27789207e-02 5.67308537e-02 7.10522752e-02 0.92469679 0.08326064 267.00 2.27262553e-02 8.58850323e-02 8.88409897e-02 1.31211268 0.11739871 267.25 3.46861379e-02 9.82808767e-02 1.04222161e-01 1.23151484 0.15492568 267.50 -7.43445462e-03 1.29369961e-01 1.29583402e-01 1.62819981 0.27456855 267.75 1.16382800e-02 1.21745869e-01 1.22300883e-01 1.47549107 0.22375530 268.00 4.06456097e-02 1.21043410e-01 1.27685445e-01 1.24683312 0.28830940 268.25 4.47900578e-02 8.65488153e-02 9.74517660e-02 1.09323740 0.15452697 268.50 5.16486183e-02 5.59709930e-02 7.61599097e-02 0.82554004 0.13491393 268.75 3.36167771e-02 5.76859916e-02 6.67664686e-02 1.04315379 0.08323898 269.00 -7.06345622e-03 9.10542103e-02 9.13277703e-02 1.64821546 0.14910922 269.25 -1.34677985e-02 8.60285676e-02 8.70763805e-02 1.72608620 0.12505524 269.50 -6.89252310e-03 7.25526402e-02 7.28793008e-02 1.66551238 0.12784858 269.75 -5.21476461e-03 7.18554532e-02 7.20444302e-02 1.64324230 0.08799911 270.00 9.14416292e-03 6.81611483e-02 6.87717810e-02 1.43743751 0.08776426 270.25 -2.86238045e-02 7.11008024e-02 7.66462412e-02 1.95352539 0.07792183 270.50 -5.59036730e-02 5.85211512e-02 8.09317354e-02 2.33332339 0.08575558 270.75 -9.20441642e-02 5.74004176e-02 1.08475509e-01 2.58398760 0.11628476 271.00 -1.03667156e-01 8.54252456e-02 1.34329266e-01 2.45236776 0.18481428 271.25 -1.01512190e-01 8.14977954e-02 1.30179167e-01 2.46512391 0.11422724 271.50 -9.13193359e-02 1.05605068e-01 1.39612505e-01 2.28377711 0.10796457 271.75 -1.50616071e-01 9.54047659e-02 1.78289849e-01 2.57695414 0.13033839 272.00 -1.85990616e-01 1.32607409e-01 2.28423366e-01 2.52220894 0.23904587 272.25 -2.04614919e-01 9.86426036e-02 2.27151113e-01 2.69237623 0.15708784 272.50 -1.95542125e-01 4.68990708e-02 2.01087656e-01 2.90619777 0.15384792 272.75 -2.24458125e-01 5.72570309e-02 2.31645888e-01 2.89182914 0.14051511 273.00 -2.11755899e-01 2.65119934e-02 2.13409106e-01 3.01704002 0.10572215 273.25 -2.15557240e-01 3.12020808e-02 2.17803796e-01 2.99784032 0.10934309 273.50 -2.46113673e-01 -3.97701039e-02 2.49306240e-01 -2.98138511 0.15394051 273.75 -7.41806397e-02 -9.78889109e-03 7.48237241e-02 -3.01039052 0.01177767 274.00 7.93543134e-03 -5.34282024e-02 5.40142933e-02 -1.42334909 0.00604749 274.25 8.88123783e-02 -8.61969767e-02 1.23764120e-01 -0.77045492 0.04385670 274.50 1.38129804e-01 -1.10964555e-01 1.77180629e-01 -0.67677139 0.10338075 274.75 1.58544013e-01 -9.02347063e-02 1.82423974e-01 -0.51742379 0.13503421 275.00 1.94298589e-01 -1.01508797e-01 2.19216737e-01 -0.48143577 0.22896210 275.25 1.87098253e-01 -5.74062748e-02 1.95707017e-01 -0.29770573 0.23479398 275.50 2.07555907e-01 -4.55400749e-02 2.12493184e-01 -0.21598855 0.34389165 275.75 1.83256215e-01 -5.64368132e-02 1.91749718e-01 -0.29874958 0.39069025 276.00 1.77280774e-01 -5.75712348e-02 1.86394528e-01 -0.31400221 0.35376190 276.25 1.75979209e-01 -4.15822640e-02 1.80825238e-01 -0.23203483 0.38947774 276.50 1.61382948e-01 -4.47171934e-02 1.67463678e-01 -0.27030588 0.42213990 276.75 1.45231341e-01 -1.74098773e-02 1.46271140e-01 -0.11930753 0.45935309 277.00 1.49294641e-01 -3.83909907e-03 1.49343994e-01 -0.02570925 0.43002326 277.25 1.38544409e-01 4.51075355e-02 1.45702585e-01 0.31475801 0.41900555 277.50 1.40990637e-01 5.15568026e-02 1.50121496e-01 0.35057069 0.43947832 277.75 1.15583065e-01 2.73722206e-02 1.18779979e-01 0.23253469 0.44866201 278.00 1.31585268e-01 3.48870873e-02 1.36131523e-01 0.25916638 0.46894085 278.25 1.43023829e-01 3.55112749e-02 1.47366435e-01 0.24336787 0.53181288 278.50 1.46718697e-01 5.20906541e-02 1.55691401e-01 0.34115559 0.54312748 278.75 1.75359309e-01 7.03079669e-02 1.88928816e-01 0.38131354 0.69942396 279.00 1.68439046e-01 5.65711568e-02 1.77685138e-01 0.32401866 0.62442198 279.25 1.69508865e-01 3.49026651e-02 1.73064876e-01 0.20306662 0.68694336 279.50 1.58459985e-01 2.87568084e-02 1.61048195e-01 0.17952301 0.59422773 279.75 1.64249462e-01 2.37316175e-02 1.65955040e-01 0.14349219 0.69472769 280.00 1.49730688e-01 2.34401989e-02 1.51554352e-01 0.15528866 0.61604452 280.25 1.32537461e-01 2.29362591e-02 1.34507437e-01 0.17135776 0.57946761 280.50 1.20935900e-01 3.06302759e-02 1.24754582e-01 0.24806047 0.42707706 280.75 1.23348031e-01 5.10193332e-02 1.33482991e-01 0.39219317 0.50154107 281.00 1.06835115e-01 6.63425557e-02 1.25758008e-01 0.55570388 0.35664411 281.25 9.58756373e-02 5.10193517e-02 1.08605304e-01 0.48902853 0.30703262 281.50 8.69614163e-02 5.86989413e-02 1.04918319e-01 0.59374955 0.22457817 281.75 1.16487272e-01 6.02987400e-02 1.31168680e-01 0.47766163 0.31142651 282.00 1.28186730e-01 4.87607291e-02 1.37147535e-01 0.36348625 0.33549760 282.25 1.48257287e-01 3.58930460e-02 1.52540270e-01 0.23752938 0.51973450 282.50 1.25361176e-01 2.13928889e-02 1.27173425e-01 0.16902186 0.45760274 282.75 1.23059041e-01 3.39358031e-02 1.27652521e-01 0.26908051 0.53177548 283.00 1.19321189e-01 1.74520150e-02 1.20590709e-01 0.14523106 0.52725202 283.25 1.21773048e-01 1.48797653e-02 1.22678778e-01 0.12158984 0.61543107 283.50 1.34201132e-01 1.06251255e-03 1.34205338e-01 0.00791715 0.55606863 283.75 1.34070821e-01 -9.14284575e-03 1.34382204e-01 -0.06808873 0.64539936 284.00 1.35216546e-01 -3.02224125e-03 1.35250317e-01 -0.02234740 0.59197186 284.25 1.34833827e-01 -1.55962534e-02 1.35732840e-01 -0.11515841 0.60794812 284.50 1.06289697e-01 -4.99378005e-02 1.17436296e-01 -0.43921942 0.49931181 284.75 8.33933731e-02 -7.23897541e-02 1.10429757e-01 -0.71488107 0.49645091 285.00 4.12529819e-02 -6.18161525e-02 7.43171934e-02 -0.98232110 0.29411586 285.25 2.46199387e-02 -4.66809595e-02 5.27754996e-02 -1.08546304 0.21620956 285.50 3.02257032e-03 -3.88070137e-02 3.89245455e-02 -1.49306604 0.15617665 285.75 -1.54490650e-03 -2.85265908e-02 2.85683937e-02 -1.62490019 0.10031774 286.00 -2.58239175e-02 -7.21171730e-03 2.68120044e-02 -2.86926561 0.07857096 286.25 -3.58609076e-02 -4.35051625e-03 3.61238382e-02 -3.02086622 0.13566799 286.50 -5.23173235e-02 5.55905768e-03 5.26118376e-02 3.03573332 0.26416540 286.75 -7.39935786e-02 1.69991296e-02 7.59211438e-02 2.91577321 0.42664578 287.00 -1.20042039e-01 5.99435686e-02 1.34176460e-01 2.67846134 0.56054690 287.25 -1.29488971e-01 1.08807573e-01 1.69134507e-01 2.44276606 0.62908808 287.50 -8.17901357e-02 1.87821069e-01 2.04856975e-01 1.98150026 0.74322552 287.75 -3.84044397e-02 2.28318034e-01 2.31525432e-01 1.73744226 0.77071853 288.00 2.65417115e-02 2.33610502e-01 2.35113439e-01 1.45766621 0.84250654 288.25 4.91285495e-02 2.21783349e-01 2.27159566e-01 1.35280052 0.83779602 288.50 7.74521837e-02 1.87554944e-01 2.02917958e-01 1.17917001 0.83428322 288.75 8.71911350e-02 1.80820003e-01 2.00744035e-01 1.12149106 0.81623467 289.00 1.03914287e-01 1.57998867e-01 1.89107962e-01 0.98903406 0.82998975 289.25 1.05028749e-01 1.48889501e-01 1.82206261e-01 0.95644599 0.82256482 289.50 9.63569891e-02 1.37144619e-01 1.67610608e-01 0.95833153 0.83198190 289.75 9.98673423e-02 1.31619181e-01 1.65218325e-01 0.92171248 0.80768290 290.00 1.10967314e-01 1.34320191e-01 1.74228754e-01 0.88031820 0.85414712 290.25 1.12503067e-01 1.29907330e-01 1.71851257e-01 0.85707186 0.77880023 290.50 1.23632009e-01 1.10206095e-01 1.65620823e-01 0.72804570 0.80140248 290.75 1.10226272e-01 9.28810386e-02 1.44141314e-01 0.70020551 0.73488544 291.00 9.54722253e-02 9.18438242e-02 1.32477296e-01 0.76603011 0.79434715 291.25 8.71232853e-02 9.25059027e-02 1.27074029e-01 0.81535436 0.74899768 291.50 8.13905386e-02 8.38107798e-02 1.16827508e-01 0.80004737 0.72747789 291.75 5.65985078e-02 7.66759437e-02 9.53026308e-02 0.93492110 0.57982102 292.00 4.17241183e-02 8.56196200e-02 9.52450596e-02 1.11734441 0.72629989 292.25 2.80111443e-02 8.05836507e-02 8.53132403e-02 1.23625823 0.46968408 292.50 -7.68115948e-03 9.50468728e-02 9.53567420e-02 1.65143552 0.54609989 292.75 -2.72024249e-02 1.38605250e-01 1.41249380e-01 1.76459148 0.55193628 293.00 -4.54150156e-02 2.07002951e-01 2.11926273e-01 1.78676766 0.74708040 293.25 -2.55886828e-02 2.85119785e-01 2.86265738e-01 1.66030366 0.77922903 293.50 -2.56157707e-02 3.38639084e-01 3.39606532e-01 1.64629582 0.81570742 293.75 4.95758357e-02 4.20181649e-01 4.23096185e-01 1.45335262 0.81782005 294.00 1.30497398e-01 4.67782291e-01 4.85643740e-01 1.29874266 0.88161279 294.25 3.42337543e-01 5.07210772e-01 6.11929539e-01 0.97708693 0.84441581 294.50 5.01671120e-01 4.50856496e-01 6.74496473e-01 0.73210154 0.86972606 294.75 6.29273023e-01 2.77832115e-01 6.87877331e-01 0.41577362 0.79077495 295.00 6.61768411e-01 7.17546366e-02 6.65647172e-01 0.10800667 0.76384985 295.25 5.09085473e-01 -2.23175308e-01 5.55855410e-01 -0.41315281 0.81637580 295.50 4.34241730e-01 -2.94989038e-01 5.24961344e-01 -0.59671144 0.83003903 295.75 1.94122219e-01 -2.73443135e-01 3.35342488e-01 -0.95344492 0.66984161 296.00 1.17210797e-01 -2.48792507e-01 2.75020149e-01 -1.13051956 0.71171295 296.25 2.77260597e-02 -1.76772902e-01 1.78934047e-01 -1.41521819 0.64639604 296.50 1.45525093e-02 -1.26259029e-01 1.27094917e-01 -1.45604353 0.52246540 296.75 3.82060708e-02 -3.73344511e-02 5.34187709e-02 -0.77386024 0.18284770 297.00 3.53264605e-02 -1.51853913e-02 3.84519820e-02 -0.40597892 0.13694599 297.25 4.89447691e-02 7.08519426e-03 4.94549331e-02 0.14376034 0.27645408 297.50 5.47054752e-02 1.65275230e-02 5.71475987e-02 0.29339902 0.36386251 297.75 6.61779661e-02 2.20822891e-02 6.97649675e-02 0.32206287 0.46185209 298.00 6.30146266e-02 3.29335925e-02 7.11017910e-02 0.48159050 0.44326926 298.25 6.89769896e-02 4.46725544e-02 8.21794513e-02 0.57471741 0.63700401 298.50 7.43032451e-02 4.84649106e-02 8.87120048e-02 0.57796116 0.66401719 298.75 7.66790316e-02 4.81713259e-02 9.05546825e-02 0.56091170 0.78446802 299.00 7.49031657e-02 5.18108472e-02 9.10760568e-02 0.60513670 0.78309873 299.25 7.82797162e-02 6.23031481e-02 1.00046970e-01 0.67223846 0.84681341 299.50 8.34503689e-02 6.39704842e-02 1.05148404e-01 0.65402135 0.81202082 299.75 8.46503935e-02 6.79831734e-02 1.08569798e-01 0.67663151 0.78973093 300.00 8.73400309e-02 6.37392851e-02 1.08124824e-01 0.63043630 0.73696332 300.25 9.64201787e-02 5.67540587e-02 1.11883305e-01 0.53200377 0.75537642 300.50 9.81490889e-02 5.19589976e-02 1.11053956e-01 0.48688105 0.72374318 300.75 9.84762218e-02 5.82742631e-02 1.14426640e-01 0.53433845 0.80480996 301.00 8.97007430e-02 5.32706719e-02 1.04326352e-01 0.53590071 0.67133715 301.25 8.89914388e-02 5.35302286e-02 1.03850670e-01 0.54153721 0.74864149 301.50 7.97773682e-02 5.26245957e-02 9.55707934e-02 0.58312441 0.63436690 301.75 7.52964435e-02 5.75057554e-02 9.47442152e-02 0.65222722 0.65759122 302.00 7.37820140e-02 5.95874059e-02 9.48390453e-02 0.67936656 0.64243284 302.25 6.58305178e-02 6.58970853e-02 9.31454933e-02 0.78590351 0.69170128 302.50 6.65569611e-02 6.02313965e-02 8.97644150e-02 0.73554876 0.60705958 302.75 7.13320672e-02 6.82377762e-02 9.87150339e-02 0.76323160 0.68658059 303.00 7.02193956e-02 7.73378358e-02 1.04460061e-01 0.83360268 0.67692248 303.25 7.20489653e-02 8.25933989e-02 1.09602568e-01 0.85347872 0.74007228 303.50 7.08825759e-02 9.83079017e-02 1.21197290e-01 0.94609774 0.66126289 303.75 5.75394945e-02 1.13773595e-01 1.27495978e-01 1.10256981 0.72619061 304.00 5.48082446e-02 1.14363465e-01 1.26818554e-01 1.12388926 0.71389005 304.25 5.55830216e-02 1.10816284e-01 1.23974679e-01 1.10588703 0.70700107 304.50 6.82877430e-02 1.28320733e-01 1.45359645e-01 1.08174941 0.74600609 304.75 7.31032946e-02 1.36309006e-01 1.54674616e-01 1.07852774 0.78208253 305.00 8.91855081e-02 1.32482822e-01 1.59705207e-01 0.97829429 0.74943036 305.25 8.85071104e-02 1.28176071e-01 1.55764610e-01 0.96646660 0.76129414 305.50 8.20987397e-02 1.24265872e-01 1.48936933e-01 0.98695672 0.79946655 305.75 7.99352332e-02 1.20064768e-01 1.44240043e-01 0.98341641 0.81562211 306.00 6.98746319e-02 1.38936136e-01 1.55517569e-01 1.10481045 0.77259102 306.25 6.58046796e-02 1.48407386e-01 1.62342256e-01 1.15343974 0.81381298 306.50 6.79697177e-02 1.26745055e-01 1.43819997e-01 1.07855456 0.71191479 306.75 5.72303581e-02 1.26608904e-01 1.38942897e-01 1.14625989 0.66467428 307.00 6.78069402e-02 1.70575856e-01 1.83558993e-01 1.19243160 0.71032592 307.25 6.37829249e-02 1.80162734e-01 1.91120047e-01 1.23053626 0.71654935 307.50 5.73490826e-02 1.89325980e-01 1.97821243e-01 1.27667026 0.69196775 307.75 3.36823658e-02 1.80987102e-01 1.84094631e-01 1.38679762 0.53475619 308.00 -6.13601211e-02 2.25733640e-01 2.33924648e-01 1.83620868 0.33031788 308.25 -7.64712723e-02 1.82904059e-01 1.98246690e-01 1.96680387 0.17124120 308.50 -9.67822940e-02 -8.09593671e-02 1.26179363e-01 -2.44498249 0.04134875 308.75 2.52151624e-02 -1.86995595e-01 1.88687988e-01 -1.43676119 0.18244003 309.00 8.18919748e-02 -1.68916754e-01 1.87720977e-01 -1.11937706 0.45270556 309.25 6.04005143e-02 -1.67804719e-01 1.78344178e-01 -1.22528920 0.46167261 309.50 4.43321598e-02 -1.27241132e-01 1.34742889e-01 -1.23553815 0.40257110 309.75 3.88466862e-02 -9.55614281e-02 1.03155473e-01 -1.18469042 0.31978051 310.00 4.47833163e-02 -5.05288590e-02 6.75182272e-02 -0.84560661 0.20860090 310.25 3.52608667e-02 -2.76210817e-02 4.47912142e-02 -0.66449662 0.09935518 310.50 4.24581569e-02 -1.91794118e-02 4.65891074e-02 -0.42428753 0.15420966 310.75 4.45700066e-02 -2.16524229e-02 4.95511141e-02 -0.45222891 0.13246651 311.00 2.91965685e-02 -3.50806053e-02 4.56408642e-02 -0.87668536 0.17216267 311.25 1.82670841e-02 -1.87198154e-02 2.61556466e-02 -0.79763787 0.06341644 311.50 1.96191934e-02 -1.79274883e-02 2.65764480e-02 -0.74037257 0.09513024 311.75 9.48671308e-03 -2.51720325e-03 9.81499044e-03 -0.25936328 0.01194774 312.00 -2.59158979e-03 1.16836013e-02 1.19675761e-02 1.78907651 0.01787281 312.25 2.46291647e-03 2.71965313e-02 2.73078244e-02 1.48048273 0.05803112 312.50 2.08614859e-02 5.02940584e-02 5.44490028e-02 1.17760510 0.31125647 312.75 2.95535978e-02 4.65824296e-02 5.51664562e-02 1.00543991 0.31674244 313.00 4.39262329e-02 3.76827908e-02 5.78749226e-02 0.70904259 0.45576456 313.25 3.88105359e-02 3.00892128e-02 4.91082318e-02 0.65948788 0.40828660 313.50 3.34539851e-02 2.56338995e-02 4.21457699e-02 0.65381617 0.43532539 313.75 3.81091773e-02 3.13890696e-02 4.93718856e-02 0.68900321 0.40102432 314.00 3.39754684e-02 3.32514901e-02 4.75393947e-02 0.77462941 0.37176544 314.25 3.09127645e-03 3.80146111e-02 3.81400924e-02 1.48965675 0.14521751 314.50 -1.61955020e-02 5.38056071e-02 5.61901917e-02 1.86317054 0.17657579 314.75 4.48220169e-02 1.11311746e-01 1.19997158e-01 1.18798945 0.19346493 315.00 2.15677856e-01 1.11098534e-01 2.42610433e-01 0.47566502 0.36077892 315.25 2.53077362e-01 -8.36422245e-02 2.66541128e-01 -0.31919895 0.45327533 315.50 2.03068436e-01 -1.58920469e-01 2.57861407e-01 -0.66403805 0.56552407 315.75 7.10448596e-02 -2.09380712e-01 2.21105528e-01 -1.24367692 0.65974749 316.00 3.99364448e-02 -2.27778667e-01 2.31253196e-01 -1.39723044 0.82869318 316.25 2.95551116e-03 -1.91051148e-01 1.91074007e-01 -1.55532782 0.79141899 316.50 -1.89730530e-02 -1.72862251e-01 1.73900358e-01 -1.68011696 0.81836181 316.75 -5.35613909e-02 -1.41908386e-01 1.51679968e-01 -1.93170131 0.85662797 317.00 -5.90523931e-02 -1.28625595e-01 1.41533490e-01 -2.00119445 0.87785784 317.25 -5.85768977e-02 -1.08429666e-01 1.23240600e-01 -2.06610721 0.86674626 317.50 -6.59255223e-02 -9.70915012e-02 1.17358145e-01 -2.16729163 0.87664126 317.75 -6.32919287e-02 -9.71180687e-02 1.15921471e-01 -2.14836630 0.86696323 318.00 -6.30166118e-02 -9.47236723e-02 1.13770240e-01 -2.15782988 0.84730730 318.25 -6.96044361e-02 -8.64855386e-02 1.11015881e-01 -2.24846339 0.88013025 318.50 -7.04373601e-02 -7.98285505e-02 1.06461351e-01 -2.29377852 0.87573959 318.75 -7.23207958e-02 -7.36765356e-02 1.03240154e-01 -2.34690870 0.82979810 319.00 -6.79492274e-02 -7.30125493e-02 9.97393095e-02 -2.32029011 0.80258283 319.25 -6.25452696e-02 -7.80747924e-02 1.00037913e-01 -2.24620416 0.80708719 319.50 -5.98079865e-02 -7.94822730e-02 9.94707342e-02 -2.21587605 0.75633952 319.75 -6.84052958e-02 -8.99707970e-02 1.13022249e-01 -2.22086042 0.81387952 320.00 -6.98730052e-02 -9.77675853e-02 1.20169620e-01 -2.19131001 0.78385164 320.25 -6.99709959e-02 -1.03806427e-01 1.25186719e-01 -2.16389488 0.79268352 320.50 -9.04169357e-02 -1.19460957e-01 1.49820368e-01 -2.21868253 0.76719719 320.75 -1.34960615e-01 -1.34028871e-01 1.90205431e-01 -2.35965834 0.85095493 321.00 -1.63816346e-01 -1.11428606e-01 1.98121502e-01 -2.54427621 0.83252346 321.25 -1.74776033e-01 -7.97560335e-02 1.92113734e-01 -2.71348488 0.88525066 321.50 -1.66814500e-01 -7.21134705e-02 1.81734504e-01 -2.73355734 0.87541426 321.75 -1.60044358e-01 -6.44206072e-02 1.72523074e-01 -2.75891816 0.92182073 322.00 -1.63439477e-01 -6.50200449e-02 1.75897893e-01 -2.76296408 0.89592244 322.25 -1.76328748e-01 -5.61554605e-02 1.85054757e-01 -2.83327798 0.89406978 322.50 -1.75480956e-01 -5.81564572e-02 1.84866816e-01 -2.82157249 0.84498318 322.75 -1.66369770e-01 -6.14729914e-02 1.77363551e-01 -2.78765598 0.85648672 323.00 -1.73578932e-01 -5.78672844e-02 1.82970676e-01 -2.81980248 0.83731813 323.25 -1.77860889e-01 -5.12320931e-02 1.85092472e-01 -2.86113872 0.90310420 323.50 -1.84661559e-01 -4.11009116e-02 1.89180275e-01 -2.92258825 0.89206357 323.75 -1.84662091e-01 -3.18268689e-02 1.87384731e-01 -2.97091751 0.91615864 324.00 -1.94752858e-01 -2.31242069e-02 1.96120893e-01 -3.02340981 0.89702062 324.25 -1.89008615e-01 -2.51025376e-02 1.90668282e-01 -3.00955377 0.92789093 324.50 -1.93390137e-01 -2.85037088e-02 1.95479427e-01 -2.99525657 0.88254711 324.75 -1.99955054e-01 -3.22034211e-02 2.02531687e-01 -2.98191055 0.91046990 325.00 -1.99558276e-01 -3.98427612e-02 2.03496809e-01 -2.94452907 0.88795444 325.25 -2.10752473e-01 -3.71520340e-02 2.14002053e-01 -2.96710259 0.91940557 325.50 -2.31716430e-01 -2.98373572e-02 2.33629561e-01 -3.01353066 0.93005933 325.75 -2.32707854e-01 -3.21499134e-02 2.34918203e-01 -3.00430603 0.93224364 326.00 -2.51337123e-01 -3.20201704e-02 2.53368586e-01 -3.01487599 0.92480164 326.25 -2.63395004e-01 -2.73681068e-02 2.64813032e-01 -3.03805899 0.94313274 326.50 -2.93542982e-01 -2.05006874e-02 2.94257983e-01 -3.07186708 0.91765132 326.75 -3.16395507e-01 -6.37076076e-03 3.16459639e-01 -3.12145994 0.93446221 327.00 -3.41434367e-01 2.20605335e-02 3.42146305e-01 3.07707099 0.93829676 327.25 -3.40665154e-01 3.90820902e-02 3.42899631e-01 3.02736913 0.94158975 327.50 -3.35637409e-01 7.48446950e-02 3.43881082e-01 2.92218960 0.91856839 327.75 -3.53141829e-01 8.33363970e-02 3.62841710e-01 2.90984685 0.91687317 328.00 -3.59774711e-01 1.28848505e-01 3.82151515e-01 2.79768763 0.93074032 328.25 -3.59959214e-01 1.60914967e-01 3.94289567e-01 2.72120577 0.93164216 328.50 -3.65187445e-01 2.44057412e-01 4.39233298e-01 2.55245513 0.90705094 328.75 -3.21395274e-01 2.69100283e-01 4.19177629e-01 2.44452524 0.88080719 329.00 -2.34231856e-01 2.73409118e-01 3.60023761e-01 2.27917203 0.84257883 329.25 -1.94439762e-01 2.64204289e-01 3.28040740e-01 2.20524123 0.81365520 329.50 -1.61266262e-01 1.97087946e-01 2.54657546e-01 2.25656379 0.80518654 329.75 -1.56359410e-01 1.73986552e-01 2.33922178e-01 2.30288541 0.78529228 330.00 -1.42306655e-01 1.68865450e-01 2.20831891e-01 2.27105002 0.81675901 330.25 -1.61574484e-01 1.60317981e-01 2.27614079e-01 2.36009796 0.81250547 330.50 -1.80354451e-01 1.55936740e-01 2.38419787e-01 2.42867613 0.85468385 330.75 -1.78915913e-01 1.80703352e-01 2.54292362e-01 2.35122417 0.80385491 331.00 -1.85498210e-01 2.11857771e-01 2.81590662e-01 2.28995415 0.86511736 331.25 -1.45213819e-01 2.05215962e-01 2.51397384e-01 2.18661453 0.84026457 331.50 -9.61919011e-02 2.00555400e-01 2.22430551e-01 2.01801358 0.85889507 331.75 -7.35985460e-02 1.79730421e-01 1.94215782e-01 1.95946038 0.77008415 332.00 -3.94773964e-02 1.48086206e-01 1.53257917e-01 1.83132143 0.70266087 332.25 -3.29329449e-02 1.23840781e-01 1.28144909e-01 1.83071058 0.48702943 332.50 -4.39909330e-02 9.70668324e-02 1.06570034e-01 1.99631028 0.47877091 332.75 -5.84271816e-02 6.38562120e-02 8.65525931e-02 2.31182651 0.32516228 333.00 -7.17291919e-02 2.98230367e-02 7.76819830e-02 2.74756353 0.30996774 333.25 -5.63311146e-02 -1.10416558e-02 5.74030716e-02 -2.94803324 0.13091968 333.50 -2.36097929e-02 -4.59862375e-02 5.16929044e-02 -2.04511427 0.17086242 333.75 -4.48827088e-02 -9.53101405e-02 1.05349326e-01 -2.01090411 0.35260824 334.00 -7.07017643e-02 -1.41749846e-01 1.58403783e-01 -2.03346619 0.60676826 334.25 -1.22516766e-01 -1.79764623e-01 2.17544657e-01 -2.16902524 0.70230489 334.50 -1.64488055e-01 -1.99372299e-01 2.58467858e-01 -2.26061400 0.83332849 334.75 -2.30269637e-01 -2.12866684e-01 3.13586242e-01 -2.39544655 0.85841913 335.00 -2.60896875e-01 -2.28823804e-01 3.47026674e-01 -2.42159367 0.89981350 335.25 -2.91236035e-01 -2.67421908e-01 3.95389561e-01 -2.39879608 0.89412165 335.50 -3.31749774e-01 -3.05867254e-01 4.51234628e-01 -2.39676480 0.89505125 335.75 -4.48187789e-01 -3.71830085e-01 5.82348612e-01 -2.44904387 0.91419132 336.00 -5.50544040e-01 -3.83946498e-01 6.71203138e-01 -2.53261735 0.93921260 336.25 -6.99107067e-01 -3.43630429e-01 7.78994585e-01 -2.68474590 0.93345655 336.50 -8.22470586e-01 -2.51475753e-01 8.60056928e-01 -2.84486304 0.94027302 336.75 -9.06457901e-01 -8.64236545e-02 9.10568490e-01 -3.04653782 0.96452692 337.00 -8.98344115e-01 -2.87875562e-02 8.98805248e-01 -3.10955848 0.97628697 337.25 -9.17804929e-01 -3.51858060e-02 9.18479139e-01 -3.10327451 0.97485983 337.50 -9.91601295e-01 -5.51547101e-03 9.91616634e-01 -3.13603052 0.97467182 337.75 -1.10786817e+00 9.32117711e-02 1.11178250e+00 3.05765419 0.98291327 338.00 -1.15956274e+00 1.59045850e-01 1.17041930e+00 3.00528301 0.97681542 338.25 -1.20149016e+00 3.84831340e-01 1.26161554e+00 2.83162210 0.97942229 338.50 -1.17954611e+00 4.86794046e-01 1.27604760e+00 2.75018953 0.98441784 338.75 -1.13138664e+00 6.77494273e-01 1.31872447e+00 2.60204299 0.98704380 339.00 -1.11510294e+00 7.49686213e-01 1.34368299e+00 2.54969863 0.98500749 339.25 -1.03499075e+00 9.39897270e-01 1.39807465e+00 2.40430865 0.98388892 339.50 -9.82978739e-01 1.00694006e+00 1.40718708e+00 2.34415372 0.98102569 339.75 -8.05096890e-01 1.17623816e+00 1.42538318e+00 2.17102161 0.97804465 340.00 -6.96984465e-01 1.24482541e+00 1.42666662e+00 2.08121263 0.97353158 340.25 -4.03395864e-01 1.26575427e+00 1.32848112e+00 1.87931957 0.97051151 340.50 -2.69424003e-01 1.25178158e+00 1.28044774e+00 1.78279465 0.94761545 340.75 -1.43055757e-02 1.11526056e+00 1.11535231e+00 1.58362274 0.94125517 341.00 7.01399573e-02 9.99429461e-01 1.00188765e+00 1.50073121 0.91889779 341.25 1.45513463e-01 8.15869471e-01 8.28744328e-01 1.39429833 0.91672804 341.50 1.31765503e-01 6.69028975e-01 6.81881161e-01 1.37633482 0.83195594 341.75 9.83873637e-02 4.44557083e-01 4.55314258e-01 1.35299162 0.66120405 342.00 2.96601991e-02 3.39164678e-01 3.40459111e-01 1.48356751 0.53181089 342.25 4.00380119e-03 2.32212066e-01 2.32246581e-01 1.55355603 0.43585467 342.50 -1.18633982e-01 1.90059123e-01 2.24045736e-01 2.12881666 0.34800739 342.75 -2.96933011e-01 1.37983314e-01 3.27427256e-01 2.70658571 0.67202614 343.00 -3.35507719e-01 1.32516608e-01 3.60729928e-01 2.76542709 0.70603558 343.25 -3.64637670e-01 1.09349659e-01 3.80680940e-01 2.85024063 0.75687036 343.50 -4.30801267e-01 1.11192331e-01 4.44919617e-01 2.88899962 0.77338007 343.75 -5.13995577e-01 1.36221451e-01 5.31740291e-01 2.88252398 0.87629630 344.00 -5.40420421e-01 1.13553330e-01 5.52221505e-01 2.93448519 0.89648133 344.25 -5.64374904e-01 8.46048609e-02 5.70681185e-01 2.99279173 0.92430676 344.50 -5.90752427e-01 5.56726507e-02 5.93369930e-01 3.04762993 0.89541585 344.75 -6.08102803e-01 3.65470995e-02 6.09200057e-01 3.08156466 0.93095582 345.00 -6.21591969e-01 -5.84742892e-02 6.24336302e-01 -3.04779686 0.91067867 345.25 -6.36292342e-01 -1.32031407e-01 6.49846317e-01 -2.93699494 0.93579900 345.50 -5.91818435e-01 -2.13461492e-01 6.29138195e-01 -2.79542861 0.85279969 345.75 -5.07180468e-01 -2.77111744e-01 5.77947183e-01 -2.64153527 0.72405981 346.00 -4.69949200e-01 -1.10132227e-01 4.82681425e-01 -2.91139751 0.32789301 346.25 -5.45357301e-01 9.47920980e-02 5.53534216e-01 2.96949555 0.28005924 346.50 -4.28272491e-01 -6.42580379e-02 4.33066302e-01 -2.99266351 0.17217659 346.75 -2.58426576e-01 -1.26031573e-01 2.87520873e-01 -2.68784296 0.05633148 347.00 -2.68155510e-01 1.00248908e-02 2.68342833e-01 3.10422544 0.04751583 347.25 -1.70996619e-01 3.64287305e-01 4.02424011e-01 2.00966602 0.11247163 347.50 -2.72707993e-01 4.24422983e-01 5.04484408e-01 2.14190812 0.39320532 347.75 -2.39572499e-01 3.33233952e-01 4.10414240e-01 2.19411555 0.43959446 348.00 -2.42088729e-01 2.33915091e-01 3.36635148e-01 2.37336417 0.43624434 348.25 -1.73438708e-01 1.30778213e-01 2.17218614e-01 2.49551651 0.28830423 348.50 -6.68355799e-02 -4.75392501e-02 8.20181385e-02 -2.52333191 0.06538540 348.75 -4.95619733e-03 -1.27040027e-01 1.27136668e-01 -1.60978943 0.16785539 349.00 1.53941344e-01 -1.80988429e-01 2.37602081e-01 -0.86597780 0.39353380 349.25 2.17905608e-01 -2.81455535e-01 3.55949537e-01 -0.91198019 0.54838452 349.50 3.03029093e-01 -4.32886146e-01 5.28409923e-01 -0.96005673 0.74500380 349.75 3.75200009e-01 -5.19386185e-01 6.40731657e-01 -0.94520024 0.78006664 350.00 5.20675696e-01 -7.36715691e-01 9.02138121e-01 -0.95555281 0.82626556 350.25 5.59766901e-01 -8.09526531e-01 9.84211455e-01 -0.96581516 0.86020976 350.50 5.73519761e-01 -8.81917991e-01 1.05200012e+00 -0.99420347 0.89581313 350.75 5.56977074e-01 -9.49033460e-01 1.10040355e+00 -1.04007323 0.91311006 351.00 5.18676765e-01 -1.03928454e+00 1.16152397e+00 -1.10789220 0.92129237 351.25 5.87012847e-01 -1.08158980e+00 1.23061796e+00 -1.07355066 0.93700677 351.50 6.68507438e-01 -1.19983371e+00 1.37350032e+00 -1.06246748 0.96704933 351.75 6.66558032e-01 -1.26351597e+00 1.42855599e+00 -1.08535848 0.96271499 352.00 6.80035734e-01 -1.41423867e+00 1.56924174e+00 -1.12258628 0.95065008 352.25 6.15871733e-01 -1.50370267e+00 1.62493684e+00 -1.18206714 0.94280561 352.50 5.12697376e-01 -1.66912538e+00 1.74609224e+00 -1.27277891 0.94941163 352.75 2.91406928e-01 -1.74069445e+00 1.76491790e+00 -1.40492602 0.95630895 353.00 6.36361691e-02 -1.68188352e+00 1.68308696e+00 -1.53297811 0.96286022 353.25 -8.50658450e-02 -1.52511172e+00 1.52748222e+00 -1.62651539 0.94699481 353.50 -2.52885139e-01 -1.34768373e+00 1.37120470e+00 -1.75628365 0.96339131 353.75 -2.93312698e-01 -1.24448267e+00 1.27858103e+00 -1.80226252 0.96578215 354.00 -3.01635232e-01 -1.09267919e+00 1.13354824e+00 -1.84013942 0.96366755 354.25 -1.88479113e-01 -9.52061826e-01 9.70539075e-01 -1.76623863 0.94993060 354.50 -1.42736538e-01 -8.66016058e-01 8.77700138e-01 -1.73414745 0.96058708 354.75 -1.38345494e-01 -8.41692406e-01 8.52986273e-01 -1.73370555 0.94374447 355.00 -4.87311412e-02 -8.06960212e-01 8.08430274e-01 -1.63111161 0.91938583 355.25 3.43167648e-03 -8.68694108e-01 8.68700886e-01 -1.56684596 0.89753037 355.50 -3.78643831e-02 -9.52432021e-01 9.53184382e-01 -1.61053087 0.91514357 355.75 -1.44678400e-01 -9.19919130e-01 9.31226635e-01 -1.72679149 0.91802036 356.00 -2.59985406e-01 -8.50334686e-01 8.89191481e-01 -1.86751521 0.92993577 356.25 -3.56224194e-01 -7.49213166e-01 8.29587877e-01 -2.01462351 0.91017842 356.50 -4.18210196e-01 -6.46788430e-01 7.70217529e-01 -2.14477418 0.93208462 356.75 -4.21885728e-01 -4.10617647e-01 5.88722702e-01 -2.36972884 0.87434763 357.00 -3.60597784e-01 -2.79583408e-01 4.56286800e-01 -2.48207449 0.80824313 357.25 -2.65674345e-01 -1.27703074e-01 2.94772679e-01 -2.69352404 0.63300730 357.50 -2.02428102e-01 -3.47102033e-02 2.05382411e-01 -2.97177482 0.47722663 357.75 -3.54878462e-02 3.73102118e-02 5.14921268e-02 2.33116656 0.03943946 358.00 6.12452196e-02 1.32156439e-01 1.45658166e-01 1.13683055 0.25536603 358.25 3.90340633e-01 2.06578781e-01 4.41634014e-01 0.48675486 0.68864072 358.50 5.65634612e-01 2.48460419e-01 6.17798587e-01 0.41388637 0.76853753 358.75 8.96458954e-01 1.97289053e-01 9.17911557e-01 0.21662274 0.80490278 359.00 1.14193872e+00 -7.45370430e-05 1.14193873e+00 -0.00006527 0.79626154 359.25 1.42769890e+00 -6.60583235e-01 1.57311613e+00 -0.43335739 0.86372956 359.50 1.40108855e+00 -1.03367262e+00 1.74112843e+00 -0.63562393 0.88933679 359.75 9.43638134e-01 -1.60090441e+00 1.85831856e+00 -1.03817724 0.91873729 360.00 6.97407236e-01 -1.56749018e+00 1.71563467e+00 -1.15217522 0.93208083 360.25 3.30160660e-01 -1.37294195e+00 1.41208203e+00 -1.33480058 0.95521692 360.50 3.02223142e-01 -1.33263575e+00 1.36647608e+00 -1.34778259 0.96988777 360.75 3.26363568e-01 -1.33302078e+00 1.37239119e+00 -1.33068937 0.97215047 361.00 3.65000843e-01 -1.35083457e+00 1.39927826e+00 -1.30689441 0.96919077 361.25 4.87542576e-01 -1.50742129e+00 1.58430322e+00 -1.25798671 0.96252412 361.50 5.29480226e-01 -1.65872282e+00 1.74118084e+00 -1.26181054 0.94654908 361.75 5.05544126e-01 -2.11191404e+00 2.17157910e+00 -1.33584028 0.92365484 362.00 5.08424284e-01 -2.30421254e+00 2.35963783e+00 -1.35362620 0.83595351 362.25 1.94232597e-02 -2.70103325e+00 2.70110308e+00 -1.56360540 0.50315801 362.50 -9.11597806e-01 -1.72619250e+00 1.95211453e+00 -2.05666839 0.18207203 362.75 -1.78256489e+00 7.21525783e-01 1.92305409e+00 2.75698243 0.29312277 363.00 -1.43125427e+00 6.77023068e-01 1.58330320e+00 2.69975468 0.48454503 363.25 -1.03385794e+00 6.66062643e-01 1.22983808e+00 2.56927047 0.65022901 363.50 -7.51469020e-01 6.20396494e-01 9.74472934e-01 2.45144863 0.64697483 363.75 -5.28481828e-01 5.49174662e-01 7.62158679e-01 2.33699515 0.73722075 364.00 -3.74422908e-01 4.22636388e-01 5.64636194e-01 2.29577890 0.67679819 364.25 -2.92372130e-01 3.45206395e-01 4.52381385e-01 2.27351632 0.74415258 364.50 -2.22317118e-01 2.86910635e-01 3.62963653e-01 2.23002229 0.65219467 364.75 -1.83937953e-01 2.79977002e-01 3.34992974e-01 2.15205942 0.73685672 365.00 -1.16127853e-01 2.56608818e-01 2.81662499e-01 1.99576730 0.63887159 365.25 -4.35276206e-02 2.75051860e-01 2.78474737e-01 1.72774716 0.69288967 365.50 8.71900805e-02 2.99207199e-01 3.11652143e-01 1.28724460 0.64979752 365.75 2.14151719e-01 2.94063176e-01 3.63777556e-01 0.94136068 0.71297364 366.00 3.90190830e-01 1.34442795e-01 4.12702979e-01 0.33181719 0.65205589 366.25 5.05341916e-01 -6.03655784e-04 5.05342276e-01 -0.00119455 0.75747866 366.50 5.67250899e-01 -3.01692616e-01 6.42488924e-01 -0.48880208 0.76688848 366.75 5.10905192e-01 -5.17156190e-01 7.26962612e-01 -0.79147846 0.83938637 367.00 3.11184691e-01 -7.03655891e-01 7.69394258e-01 -1.15441444 0.79519422 367.25 9.78166407e-02 -7.53796459e-01 7.60116568e-01 -1.44175211 0.85388599 367.50 -6.51136832e-02 -7.34743248e-01 7.37622825e-01 -1.65918642 0.90879816 367.75 -1.29941980e-01 -7.30433596e-01 7.41901716e-01 -1.74685157 0.91215288 368.00 -3.51486582e-01 -6.13511427e-01 7.07063708e-01 -2.09105819 0.84906794 368.25 -4.79473341e-01 -5.38798479e-01 7.21247867e-01 -2.29799966 0.87008086 368.50 -5.31178319e-01 -3.57784443e-01 6.40437439e-01 -2.54882777 0.66872193 368.75 -4.13681904e-01 -1.79638338e-01 4.51001830e-01 -2.73191949 0.37238338 369.00 -5.14653398e-02 9.41438682e-02 1.07292820e-01 2.07107696 0.03066864 369.25 1.75948076e-01 1.73212607e-02 1.76798619e-01 0.09812911 0.07696428 369.50 5.15739359e-01 -3.44575837e-01 6.20257684e-01 -0.58900816 0.48030979 369.75 4.52644710e-01 -7.04232979e-01 8.37156689e-01 -0.99953571 0.54775966 370.00 3.12489750e-02 -1.19174212e+00 1.19215174e+00 -1.54458108 0.75112447 370.25 -2.75819315e-01 -1.12499302e+00 1.15831153e+00 -1.81122797 0.80746438 370.50 -6.23183883e-01 -8.99244280e-01 1.09407423e+00 -2.17681455 0.86155229 370.75 -7.22703364e-01 -7.82834852e-01 1.06542506e+00 -2.31627551 0.85374738 371.00 -9.32022585e-01 -5.53975474e-01 1.08423011e+00 -2.60531584 0.85997751 371.25 -9.15215434e-01 -3.66470077e-01 9.85859832e-01 -2.76072472 0.84619019 371.50 -8.27246049e-01 -8.76375922e-02 8.31875214e-01 -3.03604736 0.88958958 371.75 -7.96406231e-01 -9.97232914e-03 7.96468663e-01 -3.12907165 0.87457012 372.00 -6.78220951e-01 1.67055775e-01 6.98492155e-01 2.90008553 0.88118436 372.25 -5.56829737e-01 2.14828913e-01 5.96833995e-01 2.77338102 0.84514020 372.50 -2.72019978e-01 2.81485367e-01 3.91444607e-01 2.33909535 0.63773574 372.75 -9.33250826e-02 2.79569145e-01 2.94734589e-01 1.89298260 0.45205777 373.00 1.48798102e-01 7.88471190e-02 1.68397576e-01 0.48727528 0.11377004 373.25 2.98422635e-01 -2.42788182e-01 3.84710502e-01 -0.68296170 0.33366079 373.50 1.78707059e-01 -7.09707843e-01 7.31861623e-01 -1.32412079 0.59460111 373.75 -1.51608933e-01 -8.20567601e-01 8.34455785e-01 -1.75349704 0.73103677 374.00 -4.01717665e-01 -7.31153005e-01 8.34243250e-01 -2.07320210 0.81472886 374.25 -5.98820311e-01 -5.06568043e-01 7.84344916e-01 -2.43945842 0.77986782 374.50 -7.99134869e-01 -3.53428766e-01 8.73801139e-01 -2.72519039 0.89828025 374.75 -7.79995339e-01 -2.06465379e-01 8.06858527e-01 -2.88282653 0.90623550 375.00 -7.50307276e-01 -9.40501209e-02 7.56178837e-01 -3.01689423 0.94396957 375.25 -7.11478033e-01 -1.27943534e-02 7.11593062e-01 -3.12361181 0.93634845 375.50 -6.61655231e-01 2.04053346e-02 6.61969805e-01 3.11076260 0.94822955 375.75 -6.09706137e-01 8.12987918e-02 6.15102485e-01 3.00903364 0.94763622 376.00 -5.78184063e-01 1.23358199e-01 5.91197138e-01 2.93138978 0.96720823 376.25 -5.58069080e-01 1.33271835e-01 5.73761693e-01 2.90717425 0.96564762 376.50 -5.51847864e-01 1.60252521e-01 5.74645051e-01 2.85897315 0.97419985 376.75 -5.06693382e-01 2.13075330e-01 5.49671975e-01 2.74352166 0.95942632 377.00 -4.76095550e-01 2.52487535e-01 5.38903449e-01 2.65397684 0.97077750 377.25 -4.27803527e-01 2.83765130e-01 5.13360017e-01 2.55591949 0.95967137 377.50 -3.87072604e-01 2.89849917e-01 4.83568170e-01 2.49884351 0.96215834 377.75 -3.23300393e-01 3.03927167e-01 4.43728371e-01 2.38707175 0.93552358 378.00 -2.63988718e-01 3.26562065e-01 4.19920023e-01 2.25063076 0.94072744 378.25 -1.99682175e-01 3.04900849e-01 3.64468790e-01 2.15061447 0.90938617 378.50 -1.64876060e-01 2.99672133e-01 3.42034358e-01 2.07378399 0.89681574 378.75 -1.20961092e-01 2.63165941e-01 2.89634077e-01 2.00163633 0.87837447 379.00 -1.05192913e-01 2.38403831e-01 2.60579999e-01 1.98634022 0.88093440 379.25 -6.36233675e-02 1.92480715e-01 2.02723355e-01 1.89003449 0.78220698 379.50 -5.19023299e-02 1.66759006e-01 1.74649414e-01 1.87253429 0.72955410 379.75 -4.66980416e-02 1.03507073e-01 1.13553605e-01 1.99461281 0.46133998 380.00 -5.40096868e-02 5.70643051e-02 7.85708673e-02 2.32870067 0.26675127 380.25 -1.10368350e-01 3.08316053e-02 1.14593894e-01 2.86918506 0.48166948 380.50 -1.34295285e-01 3.69646227e-02 1.39289651e-01 2.87299510 0.64969642 380.75 -1.64132980e-01 5.09985530e-02 1.71873463e-01 2.84033495 0.79247123 381.00 -1.85495360e-01 6.02981230e-02 1.95049718e-01 2.82730161 0.80097701 381.25 -2.53156694e-01 1.25091430e-01 2.82375951e-01 2.68265488 0.87667612 381.50 -2.39746389e-01 1.67453099e-01 2.92436098e-01 2.53190145 0.81139870 381.75 -1.20162697e-01 2.50647906e-01 2.77963031e-01 2.01783532 0.81128078 382.00 -6.26797180e-02 2.34021232e-01 2.42269858e-01 1.83249173 0.77968261 382.25 1.08198323e-03 1.86711488e-01 1.86714623e-01 1.56500144 0.80507117 382.50 1.29635313e-02 1.57613431e-01 1.58145650e-01 1.48873215 0.68625948 382.75 7.07115856e-03 9.20527369e-02 9.23239279e-02 1.49413050 0.49058832 383.00 -1.77495322e-03 8.31448749e-02 8.31638183e-02 1.59214080 0.47204079 383.25 -6.90327988e-03 7.52587862e-02 7.55747324e-02 1.66226759 0.41269115 383.50 -3.43807070e-03 6.45848803e-02 6.46763256e-02 1.62397950 0.27026314 383.75 7.64406661e-03 4.37956479e-02 4.44577387e-02 1.39799760 0.24937314 384.00 7.96638559e-03 3.37837813e-02 3.47103325e-02 1.33922160 0.13086162 384.25 -2.05359569e-03 1.91458361e-02 1.92556562e-02 1.67764850 0.04841758 384.50 -6.93763542e-03 -1.03765471e-02 1.24821278e-02 -2.16012794 0.01228213 384.75 -1.21240456e-02 -6.51314533e-02 6.62502731e-02 -1.75483722 0.26927813 385.00 -2.49071949e-02 -8.46491042e-02 8.82374025e-02 -1.85696084 0.30510538 385.25 -5.25893863e-02 -1.08924309e-01 1.20955152e-01 -2.02059493 0.46724698 385.50 -7.62219153e-02 -1.42400908e-01 1.61517179e-01 -2.06225466 0.52387077 385.75 -8.36429793e-02 -1.80646238e-01 1.99070870e-01 -2.00442550 0.63465730 386.00 -9.09206104e-02 -2.34821952e-01 2.51809266e-01 -1.94021068 0.64556061 386.25 -1.21833175e-01 -2.74904324e-01 3.00692052e-01 -1.98796756 0.71947190 386.50 -1.45172815e-01 -2.67863404e-01 3.04673513e-01 -2.06745036 0.61102135 386.75 -1.50935078e-01 -3.16161194e-01 3.50341688e-01 -2.01620032 0.69658461 387.00 -8.73562759e-02 -3.35983431e-01 3.47154123e-01 -1.82516601 0.71816906 387.25 -2.73124472e-02 -3.43478799e-01 3.44562991e-01 -1.65014649 0.76485414 387.50 -4.04588347e-02 -3.26374498e-01 3.28872666e-01 -1.69413157 0.71782843 387.75 -4.17162298e-02 -2.94450707e-01 2.97391094e-01 -1.71153444 0.76480408 388.00 1.19976914e-02 -2.17303322e-01 2.17634277e-01 -1.51564060 0.75143914 388.25 1.81991253e-02 -1.92443136e-01 1.93301756e-01 -1.47650790 0.83733022 388.50 1.91214734e-02 -1.66578760e-01 1.67672639e-01 -1.45650717 0.80029607 388.75 1.61047972e-02 -1.40874723e-01 1.41792285e-01 -1.45697048 0.75771501 389.00 1.55822174e-02 -9.68536052e-02 9.80990639e-02 -1.41127903 0.59111039 389.25 2.47478976e-02 -7.36996731e-02 7.77438117e-02 -1.24683294 0.49565087 389.50 4.29070222e-02 -4.37832730e-02 6.13024270e-02 -0.79550565 0.39392579 389.75 5.06577996e-02 -2.84487439e-02 5.80994293e-02 -0.51169537 0.39228564 390.00 6.67456159e-02 -1.67975679e-02 6.88268518e-02 -0.24654557 0.49435452 390.25 7.74769639e-02 -2.17779255e-02 8.04795500e-02 -0.27401828 0.61945311 390.50 9.18205908e-02 -2.42199963e-02 9.49611980e-02 -0.25790097 0.72507084 390.75 1.00695439e-01 -3.25666195e-02 1.05830791e-01 -0.31279949 0.79759470 391.00 1.03837169e-01 -5.17845339e-02 1.16033597e-01 -0.46261430 0.81826368 391.25 9.94731156e-02 -6.63711890e-02 1.19582756e-01 -0.58839071 0.79305413 391.50 6.51418614e-02 -8.22504912e-02 1.04921902e-01 -0.90095645 0.77516458 391.75 5.45681650e-02 -7.63157339e-02 9.38177802e-02 -0.95005309 0.76656553 392.00 5.54783533e-02 -5.73297974e-02 7.97781509e-02 -0.80180902 0.78727280 392.25 5.21492473e-02 -5.36474582e-02 7.48170687e-02 -0.79955844 0.76148109 392.50 5.45986065e-02 -3.49246173e-02 6.48130907e-02 -0.56907290 0.75565291 392.75 5.78764670e-02 -3.01240156e-02 6.52467758e-02 -0.47990347 0.72351036 393.00 6.46483050e-02 -2.16476651e-02 6.81764237e-02 -0.32311744 0.77849290 393.25 6.46393262e-02 -1.84579242e-02 6.72230426e-02 -0.27815012 0.77219822 393.50 7.78878248e-02 -9.83278849e-03 7.85060315e-02 -0.12557863 0.78241716 393.75 8.16051744e-02 -2.86296132e-03 8.16553797e-02 -0.03506870 0.74279756 394.00 9.04230437e-02 5.28901753e-03 9.05775940e-02 0.05842535 0.80339982 394.25 9.99648761e-02 1.46761361e-02 1.01036456e-01 0.14577156 0.76775505 394.50 1.15591201e-01 2.42311072e-02 1.18103651e-01 0.20663551 0.82634089 394.75 1.42796364e-01 2.03942630e-02 1.44245373e-01 0.14186125 0.80414042 395.00 1.87843287e-01 1.98880445e-02 1.88893183e-01 0.10548276 0.85020905 395.25 2.07469733e-01 -7.80963336e-04 2.07471203e-01 -0.00376421 0.75900588 395.50 2.40172141e-01 -5.33075531e-02 2.46016976e-01 -0.21841486 0.72468572 395.75 2.57039602e-01 -1.24033916e-01 2.85401067e-01 -0.44958869 0.70020717 396.00 2.38421014e-01 -1.95394119e-01 3.08258725e-01 -0.68653892 0.75096403 396.25 1.97014704e-01 -2.02029089e-01 2.82188849e-01 -0.79796350 0.73039420 396.50 1.65477474e-01 -2.09101101e-01 2.66657204e-01 -0.90133644 0.79634557 396.75 1.42692485e-01 -2.02799469e-01 2.47969292e-01 -0.95764917 0.77943319 397.00 1.40836309e-01 -1.96893753e-01 2.42078532e-01 -0.94988156 0.84836689 397.25 1.43766081e-01 -1.83048128e-01 2.32755887e-01 -0.90502117 0.84546781 397.50 1.53847634e-01 -1.82079639e-01 2.38373843e-01 -0.86924315 0.86917352 397.75 1.60697180e-01 -1.85627388e-01 2.45522119e-01 -0.85725931 0.82523015 398.00 1.84127247e-01 -2.15078509e-01 2.83128254e-01 -0.86277547 0.87402223 398.25 1.87346776e-01 -2.44085250e-01 3.07695342e-01 -0.91615972 0.84363721 398.50 1.84038684e-01 -2.65293162e-01 3.22878768e-01 -0.96429882 0.82881900 398.75 2.12492715e-01 -2.75453219e-01 3.47890256e-01 -0.91372086 0.71978468 399.00 2.23799935e-01 -2.84550967e-01 3.62016109e-01 -0.90434017 0.72214262 399.25 2.69203958e-01 -2.82464959e-01 3.90201517e-01 -0.80943150 0.46515447 399.50 2.95811990e-01 -2.01993630e-01 3.58198493e-01 -0.59911927 0.29549089 399.75 1.23556291e-01 -1.51436068e-01 1.95445747e-01 -0.88643675 0.11869201 400.00 5.18391315e-02 -1.54194317e-02 5.40837723e-02 -0.28911362 0.00894531 400.25 7.00568687e-02 7.31017990e-02 1.01251360e-01 0.80666458 0.05364537 400.50 4.49699242e-02 1.91467160e-02 4.88762807e-02 0.40252024 0.03010637 400.75 -6.40081584e-03 -7.16644614e-02 7.19497427e-02 -1.65987641 0.20860465 401.00 -2.90025648e-02 -1.05679680e-01 1.09587150e-01 -1.83864037 0.49605341 401.25 -5.58608010e-02 -1.10258560e-01 1.23601696e-01 -2.03973751 0.66502378 401.50 -6.86328260e-02 -1.08682330e-01 1.28539152e-01 -2.13405572 0.66684485 401.75 -5.86444650e-02 -1.14544266e-01 1.28683962e-01 -2.04398257 0.72056310 402.00 -6.12780722e-02 -1.24073981e-01 1.38381195e-01 -2.02953864 0.71440752 402.25 -6.81510261e-02 -1.22970009e-01 1.40592266e-01 -2.07686490 0.80333165 402.50 -5.70173667e-02 -1.28301526e-01 1.40400362e-01 -1.98898464 0.78797187 402.75 -4.48580102e-02 -1.23221019e-01 1.31132226e-01 -1.91992830 0.68993918 403.00 -4.39741530e-02 -1.13291779e-01 1.21526760e-01 -1.94104524 0.57888995 403.25 -2.38375707e-02 -1.08932144e-01 1.11509829e-01 -1.78622993 0.53095821 403.50 -2.74820192e-03 -9.33481192e-02 9.33885645e-02 -1.60022818 0.32458751 403.75 4.55304852e-02 -5.89216783e-02 7.44633417e-02 -0.91290669 0.13180352 404.00 3.46809410e-02 -5.24440760e-02 6.28740708e-02 -0.98652265 0.04438132 404.25 -1.25085164e-01 -7.21324352e-02 1.44393166e-01 -2.61850679 0.07099296 404.50 -2.38007594e-01 -1.65340158e-01 2.89801627e-01 -2.53444314 0.34116882 404.75 -1.85680267e-01 -1.51759561e-01 2.39808520e-01 -2.45638165 0.43419352 405.00 -8.12923043e-02 -1.64687813e-01 1.83658690e-01 -2.02932256 0.38047963 405.25 -2.10597734e-02 -1.95715926e-01 1.96845721e-01 -1.67798767 0.56271304 405.50 3.72434570e-04 -2.67609808e-01 2.67610068e-01 -1.56940462 0.69265659 405.75 1.58884645e-02 -3.52592991e-01 3.52950791e-01 -1.52576502 0.84041156 406.00 1.26207458e-02 -4.46227243e-01 4.46405685e-01 -1.54252064 0.87048726 406.25 7.61241180e-03 -5.48039820e-01 5.48092687e-01 -1.55690697 0.92326018 406.50 -5.76569480e-02 -6.58145534e-01 6.60666230e-01 -1.65817840 0.90962641 406.75 -1.33863998e-01 -7.84174823e-01 7.95518524e-01 -1.73987338 0.94660782 407.00 -2.66137587e-01 -8.53668760e-01 8.94192131e-01 -1.87300456 0.87281423 407.25 -5.78551682e-01 -9.52415621e-01 1.11436868e+00 -2.11668099 0.87460736 407.50 -8.89688695e-01 -7.94799286e-01 1.19300121e+00 -2.41246633 0.84994941 407.75 -1.07738774e+00 -5.92959894e-01 1.22978282e+00 -2.63846684 0.85386723 408.00 -1.04535454e+00 -1.38356813e-01 1.05447082e+00 -3.01000351 0.74399732 408.25 -9.57324655e-01 5.68634508e-02 9.59011964e-01 3.08226407 0.76113227 408.50 -7.36169390e-01 7.68568448e-02 7.40170484e-01 3.03756847 0.69443768 408.75 -6.66984574e-01 9.28411122e-02 6.73415098e-01 3.00328604 0.79234736 409.00 -6.33764539e-01 1.23539843e-01 6.45693103e-01 2.94907663 0.78249743 409.25 -6.16908848e-01 1.25828978e-01 6.29610561e-01 2.94038571 0.78320113 409.50 -5.27553620e-01 1.23890469e-01 5.41905591e-01 2.91093272 0.70398335 409.75 -4.88654460e-01 1.22079927e-01 5.03673198e-01 2.89677519 0.68679848 410.00 -4.59015419e-01 6.60874106e-02 4.63748532e-01 2.99859885 0.73688706 410.25 -4.87778854e-01 5.77222407e-02 4.91182316e-01 3.02380353 0.75677164 410.50 -5.27056427e-01 6.85505706e-02 5.31495680e-01 3.01225564 0.76661494 410.75 -5.41298851e-01 7.61107694e-02 5.46623541e-01 3.00190077 0.77546601 411.00 -5.92457240e-01 6.03724239e-02 5.95525323e-01 3.04004145 0.81902045 411.25 -5.92621218e-01 1.04562621e-01 6.01775082e-01 2.96694925 0.81867212 411.50 -5.77030900e-01 1.59737599e-01 5.98732628e-01 2.87152891 0.80298213 411.75 -6.11768208e-01 1.72199237e-01 6.35541437e-01 2.86721401 0.78533921 412.00 -6.98300346e-01 2.58203092e-01 7.44508032e-01 2.78742441 0.84838161 412.25 -7.50482974e-01 2.56908253e-01 7.93238013e-01 2.81177254 0.84467307 412.50 -7.87024735e-01 3.85493935e-01 8.76363798e-01 2.68612884 0.88797202 412.75 -7.75380348e-01 4.46423244e-01 8.94711349e-01 2.61919684 0.88934462 413.00 -7.12124729e-01 5.68729164e-01 9.11358597e-01 2.46768336 0.88366256 413.25 -6.94318756e-01 6.55079384e-01 9.54571912e-01 2.38526546 0.90325318 413.50 -6.11502850e-01 7.45828364e-01 9.64466528e-01 2.25755272 0.92690234 413.75 -5.59425202e-01 7.87316323e-01 9.65827908e-01 2.18856576 0.93370733 414.00 -4.80733511e-01 8.86696277e-01 1.00863026e+00 2.06760239 0.95804813 414.25 -4.40640540e-01 9.14994355e-01 1.01556819e+00 2.01959748 0.94622629 414.50 -4.25886647e-01 1.00329697e+00 1.08994690e+00 1.97223249 0.95815399 414.75 -3.35312901e-01 1.00992353e+00 1.06413358e+00 1.89136271 0.95376712 415.00 -2.16046158e-01 9.79245015e-01 1.00279447e+00 1.78794292 0.95873233 415.25 -1.16590647e-01 9.77819769e-01 9.84746099e-01 1.68947135 0.95193612 415.50 6.59058342e-03 9.67712952e-01 9.67735394e-01 1.56398596 0.96221335 415.75 5.82350436e-02 9.52700089e-01 9.54478276e-01 1.50974598 0.95900480 416.00 1.08466653e-01 9.51641926e-01 9.57803409e-01 1.45730765 0.95319865 416.25 1.75224549e-01 8.71042733e-01 8.88492591e-01 1.37227946 0.93811761 416.50 1.81187696e-01 7.86878988e-01 8.07469828e-01 1.34447988 0.94596521 416.75 1.75386740e-01 7.02865348e-01 7.24417150e-01 1.32625906 0.94318315 417.00 1.65699376e-01 6.60494591e-01 6.80962105e-01 1.32499744 0.93687935 417.25 1.21736278e-01 6.41350736e-01 6.52802028e-01 1.38321552 0.92391299 417.50 9.33066996e-02 6.42615763e-01 6.49354417e-01 1.42660572 0.94205718 417.75 7.59406386e-02 6.77828527e-01 6.82069273e-01 1.45922640 0.95651296 418.00 8.97588436e-02 6.92380504e-01 6.98174342e-01 1.44187729 0.96259788 418.25 1.32932245e-01 7.09114725e-01 7.21467029e-01 1.38548484 0.93964064 418.50 1.74492967e-01 7.28638189e-01 7.49240553e-01 1.33574478 0.93924965 418.75 1.72421507e-01 7.08845883e-01 7.29514676e-01 1.33218762 0.92274138 419.00 1.90011065e-01 7.12636049e-01 7.37532605e-01 1.31022697 0.94750137 419.25 1.89856458e-01 6.81697422e-01 7.07641753e-01 1.29917404 0.94143085 419.50 1.98860367e-01 6.76027912e-01 7.04669556e-01 1.28470591 0.93951645 419.75 2.28934187e-01 7.11080183e-01 7.47024691e-01 1.25932307 0.93895910 420.00 2.21141911e-01 7.48760780e-01 7.80734559e-01 1.28361666 0.95597450 420.25 2.11137531e-01 7.39807084e-01 7.69346202e-01 1.29279152 0.95048024 420.50 2.30846606e-01 7.26644799e-01 7.62432174e-01 1.26319169 0.94784584 420.75 3.13432842e-01 7.45671233e-01 8.08866944e-01 1.17288232 0.89510199 421.00 3.48463004e-01 7.40832815e-01 8.18693914e-01 1.13113522 0.89635594 421.25 3.80335136e-01 7.19982890e-01 8.14266650e-01 1.08480043 0.92638761 421.50 3.90153358e-01 7.18876432e-01 8.17926015e-01 1.07355445 0.92087282 421.75 4.90262640e-01 6.42317013e-01 8.08039975e-01 0.91885506 0.90560795 422.00 5.19495375e-01 5.65359032e-01 7.67793123e-01 0.82764933 0.90882254 422.25 5.10270143e-01 4.92968037e-01 7.09502011e-01 0.76815361 0.91619933 422.50 4.65101733e-01 4.34557282e-01 6.36521526e-01 0.75146006 0.90944862 422.75 3.04077217e-01 4.30531575e-01 5.27086701e-01 0.95586589 0.87129375 423.00 2.09044149e-01 4.81344202e-01 5.24777760e-01 1.16108130 0.87574898 423.25 1.69543861e-01 6.10518076e-01 6.33622476e-01 1.29991713 0.93200073 423.50 1.65545971e-01 6.31171985e-01 6.52520914e-01 1.31429059 0.93071717 423.75 1.40837592e-01 6.26509243e-01 6.42144111e-01 1.34967482 0.93619229 424.00 1.21298077e-01 6.65719227e-01 6.76679624e-01 1.39056739 0.92838306 424.25 1.14080429e-01 6.96955723e-01 7.06230575e-01 1.40855120 0.91309116 424.50 9.12218456e-02 7.48207280e-01 7.53747676e-01 1.44947454 0.90068742 424.75 4.61426864e-02 8.16041482e-01 8.17344999e-01 1.51431194 0.92989832 425.00 2.21368316e-02 8.64874208e-01 8.65157462e-01 1.54520648 0.92877572 425.25 -3.09343105e-04 9.30146416e-01 9.30146468e-01 1.57112890 0.93425100 425.50 -9.40208460e-04 9.68349188e-01 9.68349644e-01 1.57176727 0.91121788 425.75 -4.83539160e-02 1.06393284e+00 1.06503108e+00 1.61621335 0.89404125 426.00 -3.93615217e-02 1.14245062e+00 1.14312849e+00 1.60523629 0.89990304 426.25 -1.20269536e-03 1.22625270e+00 1.22625329e+00 1.57177712 0.89081282 426.50 5.15696052e-02 1.26063297e+00 1.26168733e+00 1.52991141 0.87383564 426.75 1.11409580e-01 1.32609030e+00 1.33076203e+00 1.48697959 0.90036451 427.00 8.07972588e-02 1.30643729e+00 1.30893338e+00 1.50902950 0.82744019 427.25 6.61500180e-02 1.39073995e+00 1.39231226e+00 1.52326753 0.85807771 427.50 1.78018179e-01 1.43284366e+00 1.44385991e+00 1.44718855 0.83874740 427.75 2.81539591e-01 1.57317481e+00 1.59816880e+00 1.39370833 0.87490924 428.00 2.76832211e-01 1.59563156e+00 1.61946786e+00 1.39901246 0.86631238 428.25 2.56284522e-01 1.66578643e+00 1.68538606e+00 1.41814132 0.86434153 428.50 2.19665257e-01 1.49136984e+00 1.50746039e+00 1.42455688 0.76458225 428.75 2.69616345e-01 1.71851795e+00 1.73953929e+00 1.41517600 0.81667310 429.00 2.62407126e-01 1.68918565e+00 1.70944601e+00 1.41668280 0.76401210 429.25 4.10943542e-01 1.89675262e+00 1.94075890e+00 1.35743752 0.82582944 429.50 4.32875703e-01 1.91967663e+00 1.96787696e+00 1.34901167 0.82855515 429.75 4.34638537e-01 1.85689487e+00 1.90708396e+00 1.34086835 0.85294837 430.00 4.11282114e-01 1.66255139e+00 1.71266754e+00 1.32828498 0.82455016 430.25 4.49102608e-01 1.63097623e+00 1.69167864e+00 1.30209717 0.81408711 430.50 4.06542722e-01 1.66095838e+00 1.70998822e+00 1.33075176 0.84168108 430.75 3.04792129e-01 1.71860885e+00 1.74542677e+00 1.39527318 0.86357748 431.00 2.62240754e-01 1.67152618e+00 1.69197222e+00 1.41517781 0.88199358 431.25 1.47539439e-01 1.67604888e+00 1.68253016e+00 1.48299453 0.89571749 431.50 -7.65179675e-02 1.81248385e+00 1.81409832e+00 1.61298846 0.87735418 431.75 -1.36287309e-01 1.94338167e+00 1.94815465e+00 1.64081064 0.90171121 432.00 4.72826123e-02 1.99589702e+00 1.99645700e+00 1.54711085 0.92455857 432.25 4.97143863e-02 1.98908752e+00 1.98970869e+00 1.54580797 0.92872700 432.50 -1.03515802e-01 1.93072829e+00 1.93350130e+00 1.62435994 0.93686919 432.75 -1.44987443e-01 1.83868554e+00 1.84439309e+00 1.64948735 0.92322703 433.00 -4.12843155e-01 1.86541153e+00 1.91054957e+00 1.78860037 0.94292324 433.25 -4.63903027e-01 1.95299508e+00 2.00733550e+00 1.80400845 0.94591169 433.50 -2.91304968e-01 2.00818877e+00 2.02920691e+00 1.71485010 0.95946636 433.75 -2.68600973e-01 1.95049910e+00 1.96890660e+00 1.70764445 0.95536649 434.00 -2.37451320e-01 1.83683387e+00 1.85211819e+00 1.69935543 0.94944004 434.25 -1.47686321e-01 1.85101474e+00 1.85689709e+00 1.65041435 0.94136881 434.50 2.20218365e-02 1.86729412e+00 1.86742397e+00 1.55900343 0.93118853 434.75 1.06713546e-01 1.80497562e+00 1.80812742e+00 1.51174319 0.92732218 435.00 1.22057529e-01 1.72031681e+00 1.72464140e+00 1.49996441 0.93896521 435.25 1.98160041e-01 1.54814293e+00 1.56077351e+00 1.44349002 0.90840452 435.50 3.81415235e-01 1.27205890e+00 1.32801032e+00 1.27948554 0.91413169 435.75 3.38943012e-01 1.02237851e+00 1.07709804e+00 1.25067506 0.88840629 436.00 2.82167012e-01 7.16740472e-01 7.70282498e-01 1.19574932 0.90264034 436.25 1.67981330e-01 5.49044204e-01 5.74166583e-01 1.27388770 0.84504962 436.50 4.38401098e-02 4.60268704e-01 4.62351852e-01 1.47583387 0.87909484 436.75 -8.55177715e-02 4.03744016e-01 4.12701490e-01 1.77952322 0.84120068 437.00 -1.99880469e-01 3.60119432e-01 4.11871591e-01 2.07750031 0.89731578 437.25 -2.75039167e-01 3.16023610e-01 4.18948046e-01 2.28696505 0.87618673 437.50 -3.33865171e-01 2.95554454e-01 4.45890556e-01 2.41698623 0.93552052 437.75 -3.87821852e-01 2.54791258e-01 4.64030575e-01 2.56032611 0.92459503 438.00 -4.20329647e-01 2.27033609e-01 4.77725101e-01 2.64635698 0.94824677 438.25 -4.63119026e-01 1.94083779e-01 5.02143153e-01 2.74474723 0.92632340 438.50 -4.67936833e-01 1.65974614e-01 4.96500204e-01 2.80074180 0.92786379 438.75 -4.77284029e-01 1.37697340e-01 4.96750040e-01 2.86071769 0.90830726 439.00 -5.02219188e-01 9.05827676e-02 5.10322791e-01 2.96314619 0.92751402 439.25 -5.43419856e-01 3.19883333e-02 5.44360536e-01 3.08279564 0.93955304 439.50 -5.57800053e-01 -1.90409069e-02 5.58124946e-01 -3.10747018 0.95664533 439.75 -6.02291227e-01 -6.15388995e-02 6.05426923e-01 -3.03977134 0.95219468 440.00 -6.51248408e-01 -9.27015021e-02 6.57813087e-01 -3.00019822 0.95664653 440.25 -6.79207020e-01 -1.47028636e-01 6.94938555e-01 -2.92841089 0.91742688 440.50 -7.21555013e-01 -1.92385257e-01 7.46762160e-01 -2.88102832 0.92406338 440.75 -8.33688741e-01 -2.36802434e-01 8.66667359e-01 -2.86483996 0.94254942 441.00 -9.09514325e-01 -2.70989403e-01 9.49026640e-01 -2.85201805 0.95287274 441.25 -9.98664100e-01 -3.36884945e-01 1.05395515e+00 -2.81624440 0.94046226 441.50 -1.07887715e+00 -3.24227436e-01 1.12654309e+00 -2.84965608 0.94056441 441.75 -1.25753143e+00 -2.34154014e-01 1.27914558e+00 -2.95749957 0.92586412 442.00 -1.29084600e+00 -1.20821199e-01 1.29648801e+00 -3.04826609 0.93328490 442.25 -1.33650114e+00 6.12046284e-02 1.33790183e+00 3.09582996 0.95114185 442.50 -1.33797945e+00 8.48684379e-02 1.34066836e+00 3.07824722 0.95637340 442.75 -1.33243220e+00 2.14168534e-01 1.34953463e+00 2.98222079 0.94630670 443.00 -1.34646300e+00 3.01877849e-01 1.37988871e+00 2.92103920 0.96119119 443.25 -1.29369682e+00 4.03685285e-01 1.35521706e+00 2.83912682 0.96446829 443.50 -1.25299806e+00 4.40102276e-01 1.32804147e+00 2.80381413 0.96005870 443.75 -1.16519203e+00 4.50661227e-01 1.24930701e+00 2.77254329 0.94869238 444.00 -1.12231276e+00 4.55788596e-01 1.21133363e+00 2.75582544 0.94988340 444.25 -1.11641280e+00 4.63683237e-01 1.20887538e+00 2.74793833 0.94300208 444.50 -1.07754890e+00 4.09499683e-01 1.15273658e+00 2.77842042 0.93236806 444.75 -1.12683762e+00 4.07917825e-01 1.19839892e+00 2.79426562 0.94778878 445.00 -1.14372952e+00 4.29784174e-01 1.22181490e+00 2.78214331 0.92995535 445.25 -1.20285748e+00 5.47039274e-01 1.32140762e+00 2.71476821 0.93117179 445.50 -1.21543198e+00 6.22227789e-01 1.36544583e+00 2.66843903 0.93574312 445.75 -1.24204854e+00 7.55633285e-01 1.45384533e+00 2.59503663 0.93960122 446.00 -1.25943006e+00 8.56781402e-01 1.52323289e+00 2.54421569 0.93137367 446.25 -1.05981754e+00 9.37628072e-01 1.41504757e+00 2.41729122 0.91708386 446.50 -9.19522446e-01 1.02645453e+00 1.37808941e+00 2.30129936 0.88874140 446.75 -7.50597204e-01 1.18786314e+00 1.40513879e+00 2.13433393 0.86723617 447.00 -5.80306680e-01 1.25761299e+00 1.38504378e+00 2.00311883 0.88658323 447.25 -4.14645978e-01 1.29824870e+00 1.36285765e+00 1.87994467 0.93004685 447.50 -2.41147742e-01 1.11403891e+00 1.13983987e+00 1.78397003 0.89059170 447.75 -1.03164104e-01 9.62011929e-01 9.67527666e-01 1.67762593 0.93411523 448.00 -4.93535545e-02 8.33354482e-01 8.34814629e-01 1.62995000 0.92464313 448.25 1.91499665e-03 7.48892781e-01 7.48895230e-01 1.56823923 0.92785427 448.50 -4.85455064e-02 5.99018493e-01 6.00982380e-01 1.65166135 0.90216083 448.75 -9.20471421e-02 5.51317929e-01 5.58949135e-01 1.73622881 0.93563378 449.00 -1.24362103e-01 5.48989221e-01 5.62898835e-01 1.79356583 0.91341499 449.25 -1.44161547e-01 5.59327637e-01 5.77607096e-01 1.82304707 0.93904144 449.50 -1.52528587e-01 5.44436156e-01 5.65398707e-01 1.84395229 0.82849391 449.75 -1.43960796e-01 5.53094922e-01 5.71523143e-01 1.82542875 0.72207508 450.00 -4.24075848e-02 5.96404985e-01 5.97910787e-01 1.64178220 0.73665513 450.25 8.35546466e-02 5.75463340e-01 5.81497580e-01 1.42660851 0.81734071 450.50 1.63320329e-01 4.43157240e-01 4.72294262e-01 1.21770288 0.78077866 450.75 1.63167599e-01 4.03325397e-01 4.35080500e-01 1.18636878 0.82074104 451.00 1.95033985e-01 2.55705873e-01 3.21595629e-01 0.91919905 0.68549731 451.25 1.60295704e-01 1.48676768e-01 2.18630954e-01 0.74781079 0.54944575 451.50 9.27727454e-03 4.95501401e-02 5.04111516e-02 1.38570918 0.06238552 451.75 -6.26060893e-02 4.31545764e-02 7.60384106e-02 2.53808190 0.18891526 452.00 -1.27341990e-01 1.28298149e-01 1.80766140e-01 2.35245425 0.56099332 452.25 -1.05946751e-01 1.60821639e-01 1.92583264e-01 2.15332195 0.64002290 452.50 -4.76579856e-02 1.43493509e-01 1.51200763e-01 1.89146027 0.57188596 452.75 -3.32687938e-02 1.32140241e-01 1.36263920e-01 1.81743908 0.53999089 453.00 1.74088090e-02 8.77643868e-02 8.94743216e-02 1.37497966 0.32049700 453.25 1.51942522e-02 5.78458070e-02 5.98080487e-02 1.31393067 0.20783202 453.50 -1.20379167e-02 1.07269096e-02 1.61238341e-02 2.41372011 0.01683897 453.75 -7.88175313e-03 -2.37303491e-02 2.50050295e-02 -1.89147079 0.04291584 454.00 -3.93300930e-03 -7.11293740e-02 7.12380265e-02 -1.62603382 0.32136890 454.25 -1.21388375e-02 -9.83579373e-02 9.91041634e-02 -1.69359033 0.51277572 454.50 -3.27616190e-02 -1.26118723e-01 1.30304474e-01 -1.82494714 0.66703340 454.75 -6.34323710e-02 -1.26441224e-01 1.41460414e-01 -2.03578285 0.68693552 455.00 -8.59906520e-02 -1.07550123e-01 1.37700476e-01 -2.24525687 0.68281375 455.25 -4.32472622e-02 -1.09042033e-01 1.17305118e-01 -1.94837768 0.54265700 455.50 2.93315511e-03 -1.32588367e-01 1.32620807e-01 -1.54867767 0.65025359 455.75 2.54906445e-02 -2.02544683e-01 2.04142405e-01 -1.44560257 0.66825735 456.00 8.96009698e-02 -3.23722299e-01 3.35893526e-01 -1.30077283 0.87091923 456.25 7.35837093e-02 -3.96082932e-01 4.02860089e-01 -1.38711189 0.86743336 456.50 2.34840824e-02 -5.34635634e-01 5.35151159e-01 -1.52689915 0.90142326 456.75 -1.19038060e-02 -6.30447112e-01 6.30559483e-01 -1.58967561 0.90161903 457.00 -1.05419377e-01 -7.63437941e-01 7.70681993e-01 -1.70801365 0.90915559 457.25 -3.03225568e-01 -9.02340577e-01 9.51926605e-01 -1.89498393 0.90779222 457.50 -4.96250105e-01 -9.91128985e-01 1.10842268e+00 -2.03499718 0.94917863 457.75 -6.41206706e-01 -9.40246873e-01 1.13807303e+00 -2.16930909 0.91880190 458.00 -9.03814869e-01 -8.53428480e-01 1.24306938e+00 -2.38486018 0.92517644 458.25 -1.02377693e+00 -6.23650151e-01 1.19877384e+00 -2.59446065 0.93164289 458.50 -1.10997643e+00 -4.56353857e-01 1.20012771e+00 -2.75152130 0.95364318 458.75 -1.11482466e+00 -3.16336531e-01 1.15883685e+00 -2.86510580 0.93644880 459.00 -1.11129315e+00 -1.50611924e-01 1.12145281e+00 -3.00688489 0.94522332 459.25 -1.07418337e+00 -4.48428654e-02 1.07511897e+00 -3.09987087 0.95210948 459.50 -1.03171197e+00 1.59274680e-03 1.03171320e+00 3.14004886 0.96541697 459.75 -9.42345546e-01 1.50382594e-02 9.42465532e-01 3.12563568 0.94365844 460.00 -9.39277381e-01 4.71277353e-02 9.40458942e-01 3.09146023 0.95271614 460.25 -1.00387144e+00 1.81562901e-02 1.00403561e+00 3.12350836 0.95320716 460.50 -1.05994778e+00 5.70869188e-02 1.06148397e+00 3.08778640 0.94944193 460.75 -1.03901974e+00 3.18997257e-01 1.08688604e+00 2.84371027 0.93216145 461.00 -9.19501559e-01 4.47904041e-01 1.02279086e+00 2.68830516 0.94112322 461.25 -7.26135024e-01 4.72377454e-01 8.66263547e-01 2.56484026 0.93061302 461.50 -6.46465905e-01 4.58715714e-01 7.92677912e-01 2.52446972 0.93665548 461.75 -5.46111241e-01 4.18947023e-01 6.88297970e-01 2.48720815 0.93111005 462.00 -5.08906735e-01 3.89135379e-01 6.40634379e-01 2.48878148 0.94067264 462.25 -4.45694017e-01 3.34210919e-01 5.57081767e-01 2.49817712 0.89779604 462.50 -4.19809056e-01 2.63124848e-01 4.95453660e-01 2.58171962 0.88204431 462.75 -3.66895140e-01 1.26409909e-01 3.88061218e-01 2.80979058 0.81317672 463.00 -3.71926961e-01 5.18716341e-02 3.75526738e-01 3.00301925 0.81008596 463.25 -4.42461783e-01 -3.44554149e-02 4.43801313e-01 -3.06387742 0.80594568 463.50 -5.21491018e-01 -2.69468100e-02 5.22186760e-01 -3.08996594 0.83480882 463.75 -6.26510610e-01 4.73322383e-02 6.28296017e-01 3.06618692 0.88111873 464.00 -6.04475272e-01 7.77509833e-02 6.09455142e-01 3.01366946 0.88797772 464.25 -5.56014789e-01 3.74061024e-02 5.57271623e-01 3.07441850 0.88974403 464.50 -5.72794191e-01 2.62478246e-02 5.73395268e-01 3.09580051 0.89341739 464.75 -6.00719739e-01 8.52486426e-02 6.06738441e-01 3.00062310 0.91394007 465.00 -6.10055191e-01 1.06358145e-01 6.19257128e-01 2.96898566 0.92773104 465.25 -5.85195061e-01 1.23902152e-01 5.98168039e-01 2.93294607 0.95540777 465.50 -5.67376305e-01 1.19666344e-01 5.79858521e-01 2.93372736 0.95504865 465.75 -5.12975162e-01 9.70444586e-02 5.22073887e-01 2.95462260 0.93602283 466.00 -4.87926042e-01 4.62837010e-02 4.90116316e-01 3.04701761 0.89955135 466.25 -4.37862524e-01 -3.25664052e-02 4.39071931e-01 -3.06735348 0.90848727 466.50 -4.49558266e-01 -8.07176044e-02 4.56747158e-01 -2.96393688 0.87363343 466.75 -5.09550146e-01 -1.73699051e-01 5.38342560e-01 -2.81305922 0.90830947 467.00 -5.34326744e-01 -2.61863388e-01 5.95044119e-01 -2.68591168 0.91848808 467.25 -5.64852432e-01 -3.45707722e-01 6.62247763e-01 -2.59237309 0.94628506 467.50 -6.17911757e-01 -4.20853751e-01 7.47618097e-01 -2.54367077 0.91877343 467.75 -7.43660371e-01 -5.09223404e-01 9.01298631e-01 -2.54117328 0.93231244 468.00 -8.89373681e-01 -6.01963139e-01 1.07393909e+00 -2.54658042 0.90433361 468.25 -1.10707866e+00 -6.88865777e-01 1.30390153e+00 -2.58498237 0.92965440 468.50 -1.37008085e+00 -6.59019500e-01 1.52033820e+00 -2.69325396 0.90183112 468.75 -1.68525651e+00 -5.28681065e-01 1.76623701e+00 -2.83760622 0.93007191 469.00 -1.95523335e+00 -2.90874066e-01 1.97675116e+00 -2.99390886 0.93137864 469.25 -2.07681020e+00 -4.26163837e-02 2.07724740e+00 -3.12107542 0.95009851 469.50 -2.08303839e+00 3.55702250e-01 2.11319025e+00 2.97246272 0.92525608 469.75 -2.01428970e+00 5.67002190e-01 2.09257126e+00 2.86720291 0.95234877 470.00 -1.92181298e+00 7.14049304e-01 2.05017841e+00 2.78585021 0.92034614 470.25 -1.91120567e+00 8.81753407e-01 2.10480312e+00 2.70933220 0.91567012 470.50 -1.77174303e+00 1.01305694e+00 2.04092080e+00 2.62217753 0.88432632 470.75 -1.73248763e+00 1.18846464e+00 2.10094302e+00 2.54033317 0.89406328 471.00 -1.55509012e+00 1.38093726e+00 2.07973388e+00 2.41544089 0.76725493 471.25 -1.58175460e+00 1.60336377e+00 2.25227063e+00 2.34941018 0.76736059 471.50 -1.17892343e+00 1.71566225e+00 2.08167178e+00 2.17284839 0.70115908 471.75 -8.34133009e-01 1.75529797e+00 1.94341165e+00 2.01441500 0.68358802 472.00 -2.15562390e-01 1.69141058e+00 1.70509146e+00 1.69755831 0.66592894 472.25 9.89640403e-03 1.81342850e+00 1.81345551e+00 1.56533909 0.74651025 472.50 2.13023867e-01 1.54414127e+00 1.55876600e+00 1.43370545 0.77408127 472.75 2.37410334e-01 1.36671069e+00 1.38717763e+00 1.39880330 0.81321547 473.00 3.04270344e-01 1.19310041e+00 1.23128755e+00 1.32109394 0.88984876 473.25 2.53246154e-01 1.08466230e+00 1.11383388e+00 1.34142600 0.90785597 473.50 1.42435435e-01 9.14682201e-01 9.25705883e-01 1.41631580 0.92700623 473.75 9.17727930e-02 8.78066438e-01 8.82849316e-01 1.46665751 0.94523204 474.00 -5.24826195e-02 8.97929718e-01 8.99462175e-01 1.62917838 0.95326030 474.25 -9.92264990e-02 9.11536934e-01 9.16921742e-01 1.67922564 0.95098540 474.50 -2.00438840e-01 9.98138844e-01 1.01806526e+00 1.76897310 0.97397903 474.75 -2.08289147e-01 1.04357836e+00 1.06416171e+00 1.76779886 0.97463504 475.00 -1.53019483e-01 1.15649873e+00 1.16657802e+00 1.70234493 0.97185734 475.25 -1.07637417e-01 1.22225861e+00 1.22698897e+00 1.65863408 0.96808223 475.50 5.55510386e-02 1.27533106e+00 1.27654034e+00 1.52726571 0.97004696 475.75 1.26502198e-01 1.31289750e+00 1.31897788e+00 1.47473941 0.96272969 476.00 3.42255896e-01 1.35780782e+00 1.40027896e+00 1.32387503 0.94298888 476.25 5.09988689e-01 1.26724771e+00 1.36601802e+00 1.18818996 0.92977374 476.50 6.63706534e-01 1.06954531e+00 1.25874284e+00 1.01540328 0.93310841 476.75 7.39638308e-01 9.41066972e-01 1.19694272e+00 0.90467695 0.93766640 477.00 7.90951835e-01 7.58316301e-01 1.09574104e+00 0.76433615 0.93852218 477.25 6.98067870e-01 6.01705592e-01 9.21600983e-01 0.71139580 0.89668819 477.50 6.34963813e-01 4.41566004e-01 7.73407770e-01 0.60764496 0.90958140 477.75 5.83745154e-01 4.22691583e-01 7.20712549e-01 0.62671995 0.90455103 478.00 5.59530612e-01 4.20416744e-01 6.99874806e-01 0.64437988 0.94218623 478.25 5.50590849e-01 3.89944615e-01 6.74690363e-01 0.61622771 0.87910651 478.50 6.05410790e-01 3.45972606e-01 6.97294248e-01 0.51917548 0.73336644 478.75 4.47930800e-01 1.11605964e-01 4.61625273e-01 0.24418692 0.22868490 479.00 -1.94791800e-01 -2.34810651e-01 3.05089965e-01 -2.26330932 0.16568289 479.25 -2.45680288e-01 -7.70082319e-02 2.57466642e-01 -2.83784348 0.23455151 479.50 -2.74414739e-01 -7.77224665e-03 2.74524784e-01 -3.11327723 0.40456246 479.75 -2.73747034e-01 6.06164261e-02 2.80377941e-01 2.92367662 0.45233542 480.00 -3.28659353e-01 7.03675777e-02 3.36107968e-01 2.93067220 0.65559796 480.25 -3.55928163e-01 1.06628770e-01 3.71556929e-01 2.85052171 0.66606688 480.50 -4.44973580e-01 1.44340580e-01 4.67798770e-01 2.82792152 0.75205517 480.75 -5.55854932e-01 1.72529380e-01 5.82014684e-01 2.84063521 0.74399792 481.00 -6.94585394e-01 1.94837321e-01 7.21394796e-01 2.86811220 0.76274377 481.25 -7.90152825e-01 4.06880217e-01 8.88759246e-01 2.66606568 0.67989418 481.50 -9.57651254e-01 5.70812080e-01 1.11486428e+00 2.60407951 0.70567694 481.75 -7.92421916e-01 1.11443483e+00 1.36744195e+00 2.18890177 0.55415129 482.00 -3.27391000e-01 1.53894400e+00 1.57338282e+00 1.78040889 0.57260731 482.25 4.70592377e-01 1.22542940e+00 1.31268213e+00 1.20413914 0.75059724 482.50 6.12799260e-01 1.11483464e+00 1.27215534e+00 1.06820093 0.88983281 482.75 5.38276992e-01 9.95227370e-01 1.13146791e+00 1.07499877 0.95174910 483.00 5.09254108e-01 9.15729960e-01 1.04780776e+00 1.06326797 0.96704309 483.25 4.94109282e-01 8.16336448e-01 9.54227006e-01 1.02650606 0.97070722 483.50 4.88411352e-01 7.76714449e-01 9.17513479e-01 1.00945682 0.97561508 483.75 5.12287233e-01 7.45620971e-01 9.04648463e-01 0.96880701 0.95970161 484.00 5.46253056e-01 7.04954948e-01 8.91826149e-01 0.91156339 0.95080077 484.25 6.11469610e-01 5.56166867e-01 8.26569216e-01 0.73807055 0.95241576 484.50 6.25151606e-01 4.75005468e-01 7.85139940e-01 0.64975916 0.94720081 484.75 5.90396402e-01 3.67460834e-01 6.95410221e-01 0.55672516 0.96030254 485.00 5.45663380e-01 3.00058846e-01 6.22722921e-01 0.50276440 0.94073610 485.25 4.23865483e-01 2.08519850e-01 4.72379589e-01 0.45718542 0.94892955 485.50 3.70101599e-01 1.97840973e-01 4.19662059e-01 0.49091073 0.93740597 485.75 2.77934267e-01 1.84232113e-01 3.33450039e-01 0.58536410 0.95012195 486.00 2.39673613e-01 1.86206333e-01 3.03506572e-01 0.66050617 0.93287848 486.25 1.80790604e-01 2.13884014e-01 2.80056448e-01 0.86905233 0.96561485 486.50 1.48761377e-01 2.28508127e-01 2.72664467e-01 0.99371049 0.95499155 486.75 1.02987903e-01 2.71403963e-01 2.90287133e-01 1.20811819 0.97175244 487.00 8.25067887e-02 3.04971312e-01 3.15934916e-01 1.30658171 0.97266122 487.25 7.27757436e-02 3.49219250e-01 3.56721731e-01 1.36534129 0.98830553 487.50 8.18567398e-02 3.81021322e-01 3.89714990e-01 1.35917782 0.98641341 487.75 9.49171444e-02 4.13711062e-01 4.24459782e-01 1.34527071 0.99174354 488.00 1.14719385e-01 4.35017960e-01 4.49890167e-01 1.31295462 0.99062277 488.25 1.37614085e-01 4.57429395e-01 4.77681157e-01 1.27856701 0.99405385 488.50 1.59982611e-01 4.66769880e-01 4.93425330e-01 1.24060015 0.99381386 488.75 1.86708485e-01 4.64850794e-01 5.00945426e-01 1.18886619 0.99694083 489.00 2.09028218e-01 4.55181281e-01 5.00882017e-01 1.14030179 0.99579841 489.25 2.29208182e-01 4.47242310e-01 5.02555544e-01 1.09720500 0.99686416 489.50 2.34561936e-01 4.28552031e-01 4.88544926e-01 1.07000075 0.99613636 489.75 2.38299066e-01 4.04184147e-01 4.69202802e-01 1.03807350 0.99638118 490.00 2.28278283e-01 4.02890252e-01 4.63067522e-01 1.05529653 0.99590469 490.25 2.24801680e-01 4.10822680e-01 4.68306598e-01 1.07010629 0.99674376 490.50 2.36426480e-01 4.08929325e-01 4.72356511e-01 1.04659065 0.99616309 490.75 2.47377304e-01 4.01077506e-01 4.71231044e-01 1.01812857 0.99616017 491.00 2.41845027e-01 3.82881375e-01 4.52865504e-01 1.00743300 0.99528386 491.25 2.34972964e-01 3.71610371e-01 4.39666421e-01 1.00695762 0.99702957 491.50 2.23582558e-01 3.76504767e-01 4.37886971e-01 1.03492058 0.99598948 491.75 2.19737296e-01 3.81225444e-01 4.40019679e-01 1.04791261 0.99667635 492.00 2.22199613e-01 3.72003081e-01 4.33311620e-01 1.03236018 0.99561439 492.25 2.15238548e-01 3.65965076e-01 4.24568098e-01 1.03914337 0.99511130 492.50 1.94516997e-01 3.66137377e-01 4.14600339e-01 1.08244850 0.99341963 492.75 1.81039612e-01 3.69942751e-01 4.11865245e-01 1.11568724 0.99257294 493.00 1.57177498e-01 3.96273020e-01 4.26306313e-01 1.19319036 0.98179991 493.25 1.33419893e-01 4.20568764e-01 4.41224380e-01 1.26360191 0.97520327 493.50 1.19937906e-01 4.71811257e-01 4.86817176e-01 1.32186171 0.97042811 493.75 1.26373110e-01 5.14191997e-01 5.29493695e-01 1.32980252 0.97289170 494.00 1.39820721e-01 5.97424528e-01 6.13568171e-01 1.34089514 0.96983031 494.25 1.56566211e-01 6.40383243e-01 6.59244777e-01 1.33101183 0.96865614 494.50 2.16792565e-01 7.15515953e-01 7.47637676e-01 1.27660074 0.96097317 494.75 2.56263375e-01 7.41868224e-01 7.84881761e-01 1.23819876 0.95738549 495.00 3.40581323e-01 7.62483907e-01 8.35091220e-01 1.15071220 0.96620058 495.25 3.77046976e-01 7.88863146e-01 8.74339456e-01 1.12493366 0.96508197 495.50 4.97516987e-01 8.55914872e-01 9.90006778e-01 1.04426331 0.96907482 495.75 5.84753887e-01 8.58368439e-01 1.03862095e+00 0.97277305 0.95763407 496.00 7.73145783e-01 7.93969130e-01 1.10821540e+00 0.79868508 0.94552186 496.25 8.50502780e-01 7.05273320e-01 1.10488254e+00 0.69231934 0.94920429 496.50 8.61718177e-01 5.26333760e-01 1.00974524e+00 0.54831973 0.95244711 496.75 7.98817517e-01 4.35417148e-01 9.09778829e-01 0.49905579 0.94967918 497.00 7.55027246e-01 3.82775998e-01 8.46512614e-01 0.46920788 0.97390095 497.25 7.29357031e-01 4.14985420e-01 8.39151105e-01 0.51729403 0.98200533 497.50 7.49584228e-01 4.37859324e-01 8.68099823e-01 0.52867331 0.98708781 497.75 7.69048646e-01 4.58922989e-01 8.95570282e-01 0.53801986 0.98563237 498.00 7.94363873e-01 4.76684373e-01 9.26413490e-01 0.54048064 0.98536892 498.25 8.33991010e-01 4.61615292e-01 9.53220689e-01 0.50552754 0.97280974 498.50 9.16209349e-01 4.25419689e-01 1.01015914e+00 0.43470324 0.97088254 498.75 9.56477105e-01 3.58333461e-01 1.02139675e+00 0.35845399 0.97090410 499.00 9.52163146e-01 2.95985495e-01 9.97106850e-01 0.30138631 0.97916826 499.25 9.51672116e-01 2.46324799e-01 9.83033938e-01 0.25327528 0.97757931 499.50 9.27184480e-01 1.91655404e-01 9.46785538e-01 0.20383608 0.97912901 499.75 8.88350244e-01 1.84018011e-01 9.07209339e-01 0.20425697 0.97354345 500.00 8.69300102e-01 1.79535024e-01 8.87646040e-01 0.20366477 0.96843057 500.25 8.69398517e-01 1.91727645e-01 8.90288308e-01 0.21705489 0.95635500 500.50 8.63005776e-01 1.73625797e-01 8.80298181e-01 0.19853693 0.95430854 500.75 7.62692880e-01 2.08132859e-01 7.90581884e-01 0.26640546 0.93819317 501.00 6.58782371e-01 2.73527400e-01 7.13310207e-01 0.39354201 0.92107636 501.25 5.55033069e-01 4.53820628e-01 7.16948304e-01 0.68540853 0.81180843 501.50 4.57744283e-01 6.45204281e-01 7.91086842e-01 0.95375196 0.73061362 501.75 2.82087450e-01 7.72022093e-01 8.21943698e-01 1.22047931 0.46319020 502.00 1.86746421e-02 1.00199697e+00 1.00217098e+00 1.55216106 0.38081273 502.25 -4.02364045e-01 2.92545056e-01 4.97473048e-01 2.51293185 0.08652360 502.50 -4.01368508e-01 -1.55465163e-01 4.30425483e-01 -2.77204946 0.07507577 502.75 -2.64544519e-01 -3.73899048e-01 4.58022161e-01 -2.18655764 0.07618786 503.00 -4.10291724e-01 -5.30301280e-01 6.70491421e-01 -2.22929090 0.21600044 503.25 -3.04282407e-01 -5.80096470e-01 6.55057019e-01 -2.05388077 0.38924949 503.50 -2.60066868e-01 -6.26219873e-01 6.78075295e-01 -1.96441933 0.54395161 503.75 -7.59009961e-02 -5.80247026e-01 5.85190202e-01 -1.70086589 0.64707874 504.00 1.61681130e-03 -5.65204055e-01 5.65206367e-01 -1.56793575 0.75708509 504.25 6.23017510e-02 -4.89028526e-01 4.92981143e-01 -1.44407993 0.76602827 504.50 1.02934792e-01 -4.66994626e-01 4.78204508e-01 -1.35384578 0.82035628 504.75 1.13732641e-01 -4.87854742e-01 5.00936486e-01 -1.34175906 0.86348115 505.00 1.37674331e-01 -4.68017119e-01 4.87846538e-01 -1.28470116 0.85507023 505.25 1.53003250e-01 -3.71975261e-01 4.02213363e-01 -1.18056409 0.81648201 505.50 1.75922115e-01 -3.30502010e-01 3.74406422e-01 -1.08165352 0.83678903 505.75 2.11002957e-01 -2.47017887e-01 3.24869334e-01 -0.86386834 0.84965170 506.00 2.53472928e-01 -2.08905915e-01 3.28466447e-01 -0.68930864 0.84216556 506.25 3.49300752e-01 -1.56337652e-01 3.82691099e-01 -0.42083396 0.90426114 506.50 3.93438962e-01 -1.47375163e-01 4.20135282e-01 -0.35840418 0.92053882 506.75 4.91376414e-01 -1.41241244e-01 5.11272793e-01 -0.27989442 0.93313744 507.00 5.48274227e-01 -1.56582038e-01 5.70195197e-01 -0.27818543 0.93904582 507.25 6.00127228e-01 -1.96188276e-01 6.31381445e-01 -0.31595949 0.96417106 507.50 6.12108759e-01 -1.89110038e-01 6.40655711e-01 -0.29964601 0.95537926 507.75 6.55680799e-01 -1.47892519e-01 6.72152890e-01 -0.22184327 0.94274105 508.00 7.40300881e-01 -1.42347365e-01 7.53862167e-01 -0.18996459 0.91481047 508.25 9.72583530e-01 -1.73554580e-01 9.87947324e-01 -0.17658824 0.94031817 508.50 1.08336612e+00 -2.72029672e-01 1.11699700e+00 -0.24601060 0.94064859 508.75 1.14316834e+00 -4.14908174e-01 1.21613430e+00 -0.34816098 0.96632317 509.00 1.15414184e+00 -5.67946815e-01 1.28631527e+00 -0.45730321 0.95969256 509.25 1.17128763e+00 -7.36447816e-01 1.38357150e+00 -0.56129184 0.97334635 509.50 1.11309310e+00 -8.44848985e-01 1.39740691e+00 -0.64924272 0.96546536 509.75 1.03730749e+00 -9.79960304e-01 1.42700001e+00 -0.75697767 0.97652456 510.00 9.67653415e-01 -1.04650016e+00 1.42531250e+00 -0.82452453 0.97309671 510.25 8.95665017e-01 -1.13203398e+00 1.44350849e+00 -0.90144447 0.98006069 510.50 7.79912638e-01 -1.17551274e+00 1.41070689e+00 -0.98501290 0.97282751 510.75 6.84445328e-01 -1.23748685e+00 1.41415668e+00 -1.06558155 0.97911597 511.00 5.70132107e-01 -1.23376396e+00 1.35912624e+00 -1.13791919 0.97983858 511.25 4.72655867e-01 -1.19481758e+00 1.28490957e+00 -1.19409891 0.97888642 511.50 3.84902066e-01 -1.08625551e+00 1.15243248e+00 -1.23026178 0.96280623 511.75 3.13303818e-01 -1.00581393e+00 1.05348040e+00 -1.26882929 0.96777479 512.00 2.79762022e-01 -8.79570104e-01 9.22989901e-01 -1.26284802 0.95539245 512.25 3.33622598e-01 -7.98632028e-01 8.65515543e-01 -1.17508881 0.97111131 512.50 3.80349813e-01 -7.28833270e-01 8.22109431e-01 -1.08981309 0.96421796 512.75 4.43062325e-01 -6.80935820e-01 8.12390186e-01 -0.99395250 0.96297236 513.00 5.43278642e-01 -6.09359569e-01 8.16376609e-01 -0.84266563 0.95391455 513.25 6.18371059e-01 -5.83282262e-01 8.50059389e-01 -0.75620603 0.96718496 513.50 7.89497164e-01 -5.77701232e-01 9.78286504e-01 -0.63170745 0.95824562 513.75 8.82539320e-01 -5.79548273e-01 1.05581810e+00 -0.58105872 0.96585932 514.00 9.87760510e-01 -6.31905619e-01 1.17259351e+00 -0.56912564 0.96230446 514.25 1.07549376e+00 -6.67549877e-01 1.26582371e+00 -0.55549509 0.96818346 514.50 1.27842971e+00 -7.26086725e-01 1.47023279e+00 -0.51652140 0.96980976 514.75 1.38015518e+00 -7.62482935e-01 1.57677156e+00 -0.50473126 0.97552831 515.00 1.59957360e+00 -7.86906414e-01 1.78265459e+00 -0.45718497 0.95242106 515.25 1.75897748e+00 -7.93247554e-01 1.92957079e+00 -0.42366099 0.95839642 515.50 2.02951659e+00 -7.88506423e-01 2.17731026e+00 -0.37057024 0.93937478 515.75 2.30063472e+00 -7.78676404e-01 2.42883863e+00 -0.32635883 0.91345985 516.00 2.93284536e+00 -7.58607151e-01 3.02936738e+00 -0.25311166 0.83752263 516.25 3.39700740e+00 -6.51381792e-01 3.45889542e+00 -0.18945203 0.81026324 516.50 3.02907346e+00 2.19089496e-01 3.03698638e+00 0.07220315 0.44432451 516.75 1.01221165e+00 7.81325901e-01 1.27868784e+00 0.65737025 0.06664189 517.00 -1.61858797e+00 -4.74758280e-01 1.68677871e+00 -2.85627889 0.21804776 517.25 -1.56537471e+00 -9.09329079e-01 1.81032520e+00 -2.61533428 0.43747746 517.50 -9.46656872e-01 -1.76293513e+00 2.00102462e+00 -2.06358668 0.80732066 517.75 -6.16373892e-01 -2.04841581e+00 2.13914097e+00 -1.86308110 0.86736602 518.00 -4.26181405e-01 -2.33171158e+00 2.37033952e+00 -1.75157704 0.90417527 518.25 -6.02809729e-01 -2.34333521e+00 2.41962796e+00 -1.82258149 0.89834032 518.50 -9.80790169e-01 -2.16529946e+00 2.37707196e+00 -1.99610758 0.88191970 518.75 -9.21589876e-01 -1.77186723e+00 1.99720839e+00 -2.05041287 0.81013103 519.00 -5.03920421e-01 -1.12934975e+00 1.23667564e+00 -1.99048905 0.69674793 519.25 -2.26932138e-01 -1.07243171e+00 1.09617880e+00 -1.77932543 0.65581853 519.50 8.44135092e-02 -9.47961941e-01 9.51712920e-01 -1.48198322 0.69844961 519.75 2.94312455e-01 -8.89385697e-01 9.36817346e-01 -1.25122244 0.73275099 520.00 4.00816788e-01 -7.99981728e-01 8.94776432e-01 -1.10632312 0.80341748 520.25 5.15458099e-01 -7.12045074e-01 8.79036540e-01 -0.94420154 0.72697257 520.50 6.05446198e-01 -4.93638763e-01 7.81181367e-01 -0.68401917 0.70771464 520.75 6.53063267e-01 -3.42520776e-01 7.37436175e-01 -0.48304186 0.66730568 521.00 8.00090449e-01 -1.74159037e-01 8.18826048e-01 -0.21433078 0.77589999 521.25 8.79556958e-01 8.29866814e-02 8.83463203e-01 0.09407206 0.79109945 521.50 9.54930703e-01 2.76594245e-01 9.94181585e-01 0.28193316 0.90104312 521.75 9.59662604e-01 4.47006673e-01 1.05866297e+00 0.43591168 0.90942530 522.00 9.82934123e-01 5.79490219e-01 1.14103830e+00 0.53270130 0.94535762 522.25 9.71183632e-01 7.41491705e-01 1.22188690e+00 0.65208072 0.92618292 522.50 9.51224063e-01 8.56316294e-01 1.27988469e+00 0.73293975 0.94286098 522.75 1.01977694e+00 1.05343526e+00 1.46617559e+00 0.80163160 0.93484709 523.00 1.09501924e+00 1.14322754e+00 1.58304654e+00 0.80693325 0.96510537 523.25 1.13746875e+00 1.12254416e+00 1.59810530e+00 0.77879449 0.95546756 523.50 1.22386972e+00 1.02310091e+00 1.59517791e+00 0.69628393 0.95008763 523.75 1.07185733e+00 8.94216883e-01 1.39588752e+00 0.69528997 0.97336843 524.00 1.03611672e+00 8.82926061e-01 1.36128479e+00 0.70574048 0.98184215 524.25 1.01536845e+00 9.04646034e-01 1.35991086e+00 0.72779447 0.98366666 524.50 1.01267557e+00 8.93915916e-01 1.35077662e+00 0.72318955 0.97964711 524.75 1.04313323e+00 8.27292464e-01 1.33136763e+00 0.67050973 0.97247627 525.00 1.00187225e+00 7.33126169e-01 1.24145962e+00 0.63172243 0.96268285 525.25 8.81233521e-01 5.66845948e-01 1.04780096e+00 0.57160938 0.95762645 525.50 7.98402134e-01 5.21359405e-01 9.53552095e-01 0.57848376 0.95484996 525.75 6.41713294e-01 4.71479740e-01 7.96297116e-01 0.63365012 0.95604658 526.00 5.83029644e-01 4.58847923e-01 7.41933274e-01 0.66676750 0.96080272 526.25 4.92819456e-01 4.51564619e-01 6.68417251e-01 0.74174154 0.95874877 526.50 4.41020021e-01 4.35520845e-01 6.19820188e-01 0.77912452 0.96469356 526.75 3.81127321e-01 4.18888441e-01 5.66326373e-01 0.83256363 0.97145061 527.00 3.56510544e-01 4.26273165e-01 5.55705479e-01 0.87428453 0.96973681 527.25 3.10129469e-01 4.20000845e-01 5.22092901e-01 0.93475935 0.97644779 527.50 2.88824375e-01 4.12243093e-01 5.03352647e-01 0.95965662 0.96510328 527.75 2.53840604e-01 4.08079558e-01 4.80587118e-01 1.01433051 0.96614922 528.00 2.44153400e-01 4.01210047e-01 4.69659861e-01 1.02411918 0.96802188 528.25 2.04376867e-01 3.77471570e-01 4.29248983e-01 1.07455158 0.95992868 528.50 1.91344407e-01 3.62959469e-01 4.10307517e-01 1.08564311 0.95540500 528.75 1.93573908e-01 3.35130444e-01 3.87018439e-01 1.04700454 0.96873114 529.00 1.68994439e-01 3.06110996e-01 3.49661354e-01 1.06636590 0.94049704 529.25 1.17260185e-01 2.99085499e-01 3.21250816e-01 1.19715136 0.95060387 529.50 9.12777409e-02 2.94148827e-01 3.07985646e-01 1.26990656 0.94418632 529.75 5.34999942e-02 2.92161209e-01 2.97019227e-01 1.38968483 0.94746182 530.00 4.05590116e-02 2.90043242e-01 2.92865354e-01 1.43185946 0.92673558 530.25 3.21204396e-02 2.75059469e-01 2.76928573e-01 1.45454650 0.92943009 530.50 3.52638594e-02 2.65431401e-01 2.67763643e-01 1.43871491 0.90256814 530.75 1.51056106e-02 2.45686799e-01 2.46150731e-01 1.50939042 0.88197820 531.00 2.63936628e-03 2.23908179e-01 2.23923735e-01 1.55900916 0.79057172 531.25 -3.32223068e-02 1.95645429e-01 1.98446103e-01 1.73900060 0.73242892 531.50 -4.59894946e-02 1.81180574e-01 1.86926279e-01 1.81937866 0.73543482 531.75 -6.02742401e-02 1.74187131e-01 1.84320755e-01 1.90393140 0.68719302 532.00 -1.02158672e-01 1.84648121e-01 2.11024461e-01 2.07614002 0.62525706 532.25 -1.39568702e-01 1.74769997e-01 2.23660399e-01 2.24467388 0.58893225 532.50 -1.23301389e-01 2.16226226e-01 2.48911658e-01 2.08904789 0.52556627 532.75 -1.21495225e-01 2.30039181e-01 2.60152098e-01 2.05670961 0.54857344 533.00 -1.50055493e-01 2.54741876e-01 2.95651948e-01 2.10312484 0.60677314 533.25 -1.45319420e-01 2.34626656e-01 2.75984423e-01 2.12533288 0.63175875 533.50 -1.42925663e-01 2.37923837e-01 2.77552693e-01 2.11174524 0.62621882 533.75 -1.38753567e-01 2.45969741e-01 2.82406916e-01 2.08440667 0.64483485 534.00 -1.11989958e-01 2.46984611e-01 2.71188401e-01 1.99649806 0.68407184 534.25 -1.11303875e-01 2.40352418e-01 2.64873248e-01 2.00447925 0.73290021 534.50 -1.12130290e-01 2.05001098e-01 2.33663545e-01 2.07131342 0.60125620 534.75 -1.16557349e-01 1.84498270e-01 2.18232049e-01 2.13423705 0.61980436 535.00 -1.61926960e-01 1.76700251e-01 2.39673359e-01 2.31259513 0.61748333 535.25 -1.73403387e-01 1.78071540e-01 2.48552224e-01 2.34291366 0.62332226 535.50 -1.77032514e-01 2.07065785e-01 2.72427514e-01 2.27816163 0.64941887 535.75 -1.84202557e-01 2.07511592e-01 2.77473679e-01 2.29675936 0.66509187 536.00 -2.21966451e-01 2.16256171e-01 3.09896493e-01 2.36922430 0.55137168 536.25 -2.47700266e-01 1.64430018e-01 2.97309019e-01 2.55555885 0.50664949 536.50 -2.73801311e-01 1.26711834e-01 3.01700260e-01 2.70815564 0.50586320 536.75 -3.32733362e-01 1.23497407e-01 3.54912806e-01 2.78619256 0.51932747 537.00 -4.78183311e-01 2.11573217e-01 5.22898179e-01 2.72503325 0.55544688 537.25 -6.19789398e-01 2.73595893e-01 6.77490672e-01 2.72588530 0.47041148 537.50 -4.72108860e-01 7.11239588e-01 8.53667691e-01 2.15680000 0.44277199 537.75 -2.32773440e-01 9.40538864e-01 9.68915285e-01 1.81341072 0.53160265 538.00 3.30747323e-01 8.07871529e-01 8.72954867e-01 1.18220786 0.56534656 538.25 4.40969792e-01 6.35856770e-01 7.73801131e-01 0.96444280 0.51552555 538.50 5.11743500e-01 6.04084420e-01 7.91706635e-01 0.86796554 0.46407322 538.75 4.37281246e-01 4.72654130e-01 6.43907458e-01 0.82425266 0.30878171 539.00 5.24657639e-01 4.53779832e-02 5.26616368e-01 0.08627595 0.15888137 539.25 1.91866346e-01 -3.54608453e-01 4.03187115e-01 -1.07483860 0.10183848 539.50 -1.75953744e-01 -5.09280107e-01 5.38819030e-01 -1.90345218 0.29025786 539.75 -1.64491879e-01 -2.82276483e-01 3.26707194e-01 -2.09842289 0.22415413 540.00 -1.78730428e-01 -2.38568124e-01 2.98092797e-01 -2.21377232 0.37491815 540.25 -1.94666188e-01 -2.20003202e-01 2.93762376e-01 -2.29516864 0.44460518 540.50 -1.68109568e-01 -2.04046748e-01 2.64378332e-01 -2.25992822 0.48091387 540.75 -1.57733920e-01 -2.16485636e-01 2.67854475e-01 -2.20046767 0.52623174 541.00 -1.62594776e-01 -2.29895468e-01 2.81583003e-01 -2.18637500 0.63555271 541.25 -1.45118805e-01 -2.07449546e-01 2.53169472e-01 -2.18121204 0.59014582 541.50 -1.39095318e-01 -2.05601473e-01 2.48232699e-01 -2.16559552 0.66510003 541.75 -1.26314496e-01 -2.89333389e-01 3.15704231e-01 -1.98242654 0.66595822 542.00 -1.46454674e-01 -3.40868754e-01 3.70999298e-01 -1.97659999 0.77071820 542.25 -1.82879791e-01 -3.53455100e-01 3.97964227e-01 -2.04827158 0.79293240 542.50 -2.38263585e-01 -3.21729759e-01 4.00349315e-01 -2.20823522 0.73435088 542.75 -2.80182652e-01 -2.65457039e-01 3.85966006e-01 -2.38317574 0.74086642 543.00 -2.20774048e-01 -2.79978556e-01 3.56551781e-01 -2.23850976 0.75231612 543.25 -2.00270369e-01 -3.52701537e-01 4.05594126e-01 -2.08721658 0.73975069 543.50 -2.33237803e-01 -4.01506251e-01 4.64335161e-01 -2.09705856 0.82452845 543.75 -2.96806077e-01 -4.29413581e-01 5.22005623e-01 -2.17558457 0.86575422 544.00 -3.02024157e-01 -4.31612659e-01 5.26790356e-01 -2.18135946 0.89620924 544.25 -3.19907585e-01 -4.80480412e-01 5.77236771e-01 -2.15820406 0.91235479 544.50 -3.40956959e-01 -5.30011358e-01 6.30209242e-01 -2.14244797 0.91760478 544.75 -3.75205164e-01 -6.34707492e-01 7.37314394e-01 -2.10468053 0.91934398 545.00 -4.38418060e-01 -6.45036583e-01 7.79924733e-01 -2.16775370 0.92670011 545.25 -6.08035525e-01 -6.86838738e-01 9.17308373e-01 -2.29541165 0.94346463 545.50 -7.20062583e-01 -6.40744399e-01 9.63869031e-01 -2.41441622 0.94144741 545.75 -8.41421780e-01 -4.39678055e-01 9.49372110e-01 -2.66007465 0.94317114 546.00 -8.70172227e-01 -3.80748201e-01 9.49825719e-01 -2.72913606 0.95310891 546.25 -7.91402942e-01 -2.01734165e-01 8.16710040e-01 -2.89200098 0.93780001 546.50 -7.20345282e-01 -1.63239537e-01 7.38609823e-01 -2.91874356 0.92764158 546.75 -5.86245228e-01 -7.57666474e-02 5.91121013e-01 -3.01306456 0.84014695 547.00 -5.38083562e-01 -5.92250603e-02 5.41333102e-01 -3.03196726 0.87321280 547.25 -4.86378014e-01 -9.48071324e-02 4.95532002e-01 -2.94908183 0.90691475 547.50 -4.28463930e-01 -1.14642739e-01 4.43536128e-01 -2.88015004 0.86950817 547.75 -3.43086071e-01 -1.63137207e-01 3.79897093e-01 -2.69773696 0.90621964 548.00 -3.17016747e-01 -1.90192043e-01 3.69692617e-01 -2.60121492 0.92329165 548.25 -2.82839893e-01 -2.33298386e-01 3.66642253e-01 -2.45188628 0.92668665 548.50 -2.48988886e-01 -2.60105835e-01 3.60070147e-01 -2.33436126 0.91796215 548.75 -2.35521427e-01 -3.11736418e-01 3.90704411e-01 -2.21781747 0.94423458 549.00 -2.28628902e-01 -3.26886632e-01 3.98906061e-01 -2.18112851 0.94486327 549.25 -2.11000963e-01 -3.38043754e-01 3.98490886e-01 -2.12880749 0.95377480 549.50 -2.00751803e-01 -3.49068736e-01 4.02678866e-01 -2.09271086 0.94948289 549.75 -1.64218979e-01 -3.51856736e-01 3.88292462e-01 -2.00746822 0.90493204 550.00 -1.44571314e-01 -3.61637697e-01 3.89464618e-01 -1.95110301 0.87518380 550.25 -9.19804746e-02 -3.89958075e-01 4.00659092e-01 -1.80243518 0.91164597 550.50 -6.62144579e-02 -4.01500294e-01 4.06923630e-01 -1.73424271 0.91919784 550.75 -3.53695790e-02 -4.32784114e-01 4.34227011e-01 -1.65234079 0.91913261 551.00 8.51231433e-03 -4.65455135e-01 4.65532966e-01 -1.55251021 0.91944257 551.25 2.64767576e-02 -4.64617144e-01 4.65370938e-01 -1.51387171 0.93827242 551.50 3.58328650e-02 -4.79764318e-01 4.81100608e-01 -1.49624627 0.90429375 551.75 7.17157134e-02 -5.13733701e-01 5.18715201e-01 -1.43209560 0.89870447 552.00 9.97682799e-02 -5.28230140e-01 5.37569336e-01 -1.38412258 0.86982657 552.25 1.25908363e-01 -5.28684497e-01 5.43470526e-01 -1.33699747 0.88356465 552.50 1.24169986e-01 -5.19428367e-01 5.34063679e-01 -1.33614864 0.82342881 552.75 1.49448464e-01 -5.43391221e-01 5.63567975e-01 -1.30240295 0.84910381 553.00 2.17704057e-01 -5.18679569e-01 5.62515379e-01 -1.17340003 0.78990098 553.25 2.78030257e-01 -5.32572238e-01 6.00777840e-01 -1.08966337 0.78063069 553.50 2.58244348e-01 -5.45802512e-01 6.03813320e-01 -1.12886167 0.69129189 553.75 2.80916791e-01 -5.89737385e-01 6.53226168e-01 -1.12625346 0.73611888 554.00 3.10934407e-01 -5.17326679e-01 6.03578576e-01 -1.02961193 0.71047429 554.25 3.68522022e-01 -5.18342928e-01 6.35993610e-01 -0.95275127 0.75392838 554.50 3.79974571e-01 -5.41629663e-01 6.61621770e-01 -0.95903793 0.63582244 554.75 4.76492405e-01 -6.71961973e-01 8.23758402e-01 -0.95398492 0.65352417 555.00 4.91380341e-01 -6.77935495e-01 8.37287988e-01 -0.94360696 0.61581094 555.25 4.94499098e-01 -6.72423305e-01 8.34675062e-01 -0.93670585 0.52973966 555.50 6.06471400e-01 -6.03679239e-01 8.55708001e-01 -0.78309088 0.40085378 555.75 5.92019922e-01 -5.22895584e-01 7.89878079e-01 -0.72347780 0.30388822 556.00 6.35902150e-01 -4.01203086e-02 6.37166527e-01 -0.06300844 0.22522623 556.25 6.38423847e-01 1.49023970e-01 6.55586113e-01 0.22931869 0.23499382 556.50 2.08422364e-01 5.23712262e-01 5.63661614e-01 1.19204019 0.27803523 556.75 8.90573360e-02 5.82455871e-01 5.89224957e-01 1.41907169 0.41436399 557.00 -1.19781329e-01 4.13363035e-01 4.30367942e-01 1.85284408 0.42764009 557.25 -2.30227200e-01 3.31990868e-01 4.04008044e-01 2.17712932 0.51785837 557.50 -3.42286321e-01 2.09682537e-01 4.01405894e-01 2.59196431 0.68886540 557.75 -3.22171380e-01 1.44140534e-01 3.52946018e-01 2.72090025 0.68599501 558.00 -3.40720101e-01 6.81663314e-02 3.47472065e-01 2.94413413 0.74252150 558.25 -3.34248419e-01 5.39358583e-02 3.38572123e-01 2.98160715 0.76142245 558.50 -3.25946210e-01 1.58472709e-02 3.26331224e-01 3.09301163 0.78591079 558.75 -3.10414663e-01 3.14946850e-02 3.12008298e-01 3.04047862 0.79315664 559.00 -2.37599607e-01 1.85687007e-02 2.38324086e-01 3.06359995 0.70364661 559.25 -2.13329374e-01 -3.06174477e-03 2.13351344e-01 -3.12724144 0.62209019 559.50 -1.64225446e-01 -5.09197161e-02 1.71938403e-01 -2.84093239 0.59852200 559.75 -1.41328779e-01 -6.02887937e-02 1.53650780e-01 -2.73837992 0.55305835 560.00 -1.23780904e-01 -8.36408196e-02 1.49390424e-01 -2.54735081 0.49997116 560.25 -1.31855737e-01 -1.02896614e-01 1.67253247e-01 -2.47893470 0.54745203 560.50 -1.31648376e-01 -1.05871416e-01 1.68938011e-01 -2.46429694 0.56827027 560.75 -1.13718947e-01 -9.60435884e-02 1.48850159e-01 -2.44025956 0.48250283 561.00 -8.53279066e-02 -1.11158613e-01 1.40132398e-01 -2.22548107 0.56298830 561.25 -5.97891215e-02 -1.21895135e-01 1.35768785e-01 -2.02681217 0.46213972 561.50 -1.31135196e-02 -1.25994782e-01 1.26675370e-01 -1.67450279 0.51726896 561.75 1.80603853e-02 -1.26723465e-01 1.28003961e-01 -1.42923157 0.56652691 562.00 5.11586130e-02 -1.52601071e-01 1.60948099e-01 -1.24732704 0.77593140 562.25 5.58561564e-02 -1.87919083e-01 1.96044617e-01 -1.28187802 0.81417492 562.50 5.09833441e-02 -2.11909937e-01 2.17956700e-01 -1.33469386 0.87424542 562.75 5.37173420e-02 -2.24350293e-01 2.30691584e-01 -1.33578552 0.86469293 563.00 4.84269290e-02 -2.33212986e-01 2.38187876e-01 -1.36605490 0.88606677 563.25 6.40573432e-02 -2.37365440e-01 2.45857063e-01 -1.30720750 0.88367832 563.50 7.09537644e-02 -2.42848784e-01 2.53001915e-01 -1.28653600 0.90971552 563.75 8.75955388e-02 -2.50677393e-01 2.65541209e-01 -1.23462464 0.90626834 564.00 9.01515078e-02 -2.58404931e-01 2.73679379e-01 -1.23512240 0.94353709 564.25 9.22615960e-02 -2.86883031e-01 3.01353738e-01 -1.25964264 0.93782321 564.50 9.13783859e-02 -3.01289137e-01 3.14841474e-01 -1.27632270 0.94190255 564.75 5.62498584e-02 -3.07633587e-01 3.12733865e-01 -1.38994717 0.94009080 565.00 2.84659022e-02 -3.15329459e-01 3.16611711e-01 -1.48076683 0.94844936 565.25 -2.98578410e-02 -3.17948556e-01 3.19347420e-01 -1.66442950 0.94740865 565.50 -5.58566733e-02 -3.02499637e-01 3.07613391e-01 -1.75339002 0.95059664 565.75 -8.14411330e-02 -2.67541608e-01 2.79662601e-01 -1.86628993 0.92148844 566.00 -9.83400932e-02 -2.38335132e-01 2.57826316e-01 -1.96212818 0.90492020 566.25 -1.08024272e-01 -1.88210035e-01 2.17007513e-01 -2.09184563 0.89305980 566.50 -1.01771734e-01 -1.57273961e-01 1.87330149e-01 -2.14512908 0.88430878 566.75 -8.44321014e-02 -1.28746487e-01 1.53962456e-01 -2.15123892 0.84831443 567.00 -8.01479716e-02 -1.11306798e-01 1.37160128e-01 -2.19486125 0.80806996 567.25 -8.29397910e-02 -7.80656851e-02 1.13900220e-01 -2.38645817 0.70266740 567.50 -7.59875664e-02 -5.56826129e-02 9.42054331e-02 -2.50919994 0.62699904 567.75 -4.76374858e-02 -2.92249671e-02 5.58876440e-02 -2.59131539 0.40340160 568.00 -3.22060566e-02 -2.68787071e-02 4.19487184e-02 -2.44611586 0.27339784 568.25 9.87877250e-04 -2.01051973e-02 2.01294526e-02 -1.52170040 0.07408197 568.50 2.05657142e-02 -2.60631420e-02 3.31999393e-02 -0.90275397 0.16559540 568.75 3.17396079e-02 -3.57490827e-02 4.78058535e-02 -0.84473800 0.31090051 569.00 1.84044775e-02 -4.35087743e-02 4.72412768e-02 -1.17061573 0.32671926 569.25 1.88202831e-03 -5.08002216e-02 5.08350720e-02 -1.53376562 0.36659363 569.50 3.33514990e-03 -3.51672463e-02 3.53250398e-02 -1.47624230 0.18722817 569.75 9.76458147e-03 -2.84470614e-02 3.00762756e-02 -1.24014347 0.17614918 570.00 1.34040453e-02 -3.48400176e-02 3.73295494e-02 -1.20352152 0.22530832 570.25 1.28276034e-02 -3.15461855e-02 3.40545038e-02 -1.18458813 0.16851719 570.50 6.41748389e-05 -3.48415769e-02 3.48416360e-02 -1.56895442 0.11419757 570.75 -5.58824217e-02 -2.51314808e-02 6.12734558e-02 -2.71897103 0.27485334 571.00 -7.23411145e-02 -8.15431090e-03 7.27992420e-02 -3.02934617 0.27312502 571.25 -7.37252832e-02 2.19684522e-02 7.69287351e-02 2.85199269 0.26765966 571.50 -8.08652710e-02 2.89402222e-02 8.58878834e-02 2.79791337 0.25241915 571.75 -7.85701714e-02 4.81420653e-02 9.21462440e-02 2.59186759 0.31788625 572.00 -7.13673624e-02 7.95515260e-02 1.06872568e-01 2.30201867 0.41562394 572.25 -7.03005724e-02 1.05270334e-01 1.26585993e-01 2.15958999 0.54261227 572.50 -5.30443954e-02 1.41906618e-01 1.51496522e-01 1.92851268 0.51704102 572.75 -2.57231499e-02 1.88453309e-01 1.90200763e-01 1.70645413 0.66162801 573.00 4.92223985e-02 1.66534066e-01 1.73656096e-01 1.28340911 0.63074664 573.25 8.30918653e-02 1.34551172e-01 1.58140052e-01 1.01757340 0.74515650 573.50 4.76760857e-02 1.01007534e-01 1.11693917e-01 1.12979428 0.63620200 573.75 2.01252852e-02 1.00832936e-01 1.02821730e-01 1.37379465 0.68626568 574.00 2.35180452e-02 1.38192064e-01 1.40178975e-01 1.40222758 0.70995703 574.25 3.89413597e-02 1.75101748e-01 1.79379630e-01 1.35196488 0.84041166 574.50 6.53902102e-02 1.87006600e-01 1.98109435e-01 1.23441737 0.81662465 574.75 9.36740416e-02 1.82923213e-01 2.05513328e-01 1.09751969 0.81126441 575.00 1.11980378e-01 1.66325963e-01 2.00509179e-01 0.97824398 0.81548554 575.25 9.72030033e-02 1.73838464e-01 1.99168862e-01 1.06094994 0.77824311 575.50 2.94939057e-02 2.06759856e-01 2.08852887e-01 1.42910412 0.67691549 575.75 -1.74830209e-02 2.17229297e-01 2.17931694e-01 1.65110510 0.55948929 576.00 -1.25777541e-01 1.38123275e-01 1.86810142e-01 2.30944685 0.19327033 576.25 -1.21080992e-01 3.03428846e-02 1.24825067e-01 2.89604946 0.04703558 576.50 6.47441284e-03 -2.15800178e-01 2.15897278e-01 -1.54080344 0.20501301 576.75 2.81961387e-02 -2.87648917e-01 2.89027545e-01 -1.47308573 0.49447780 577.00 2.41956398e-02 -2.26453664e-01 2.27742598e-01 -1.46435428 0.65711499 577.25 3.50965922e-02 -1.94630349e-01 1.97769420e-01 -1.39238923 0.71754214 577.50 6.15961642e-02 -1.41346088e-01 1.54184318e-01 -1.15982829 0.77434074 577.75 7.02422010e-02 -1.22335667e-01 1.41067297e-01 -1.04958154 0.80007455 578.00 7.72768240e-02 -1.16182025e-01 1.39534836e-01 -0.98385430 0.84539430 578.25 8.07729190e-02 -1.19079325e-01 1.43889367e-01 -0.97477493 0.85312919 578.50 4.48282588e-02 -1.25524818e-01 1.33289357e-01 -1.22778675 0.79755330 578.75 2.94682889e-02 -1.03933004e-01 1.08029854e-01 -1.29451580 0.80345500 579.00 3.29270199e-02 -8.30967284e-02 8.93826321e-02 -1.19352749 0.84771121 579.25 3.75784832e-02 -7.04891946e-02 7.98803415e-02 -1.08101302 0.82617703 579.50 4.86448469e-02 -5.74256489e-02 7.52597255e-02 -0.86799253 0.84735845 579.75 4.83411757e-02 -5.07276758e-02 7.00725792e-02 -0.80948281 0.81688210 580.00 4.94421898e-02 -3.84265455e-02 6.26189231e-02 -0.66068402 0.79203031 580.25 5.32756099e-02 -3.13101253e-02 6.17949396e-02 -0.53132698 0.76727635 580.50 6.06403237e-02 -2.29547250e-02 6.48395578e-02 -0.36186970 0.77585827 580.75 6.77248348e-02 -1.85725814e-02 7.02253090e-02 -0.26765570 0.81509530 581.00 7.80973873e-02 -2.23741336e-02 8.12391762e-02 -0.27901684 0.88444030 581.25 9.27630113e-02 -2.74292563e-02 9.67333467e-02 -0.28749959 0.86842555 581.50 1.11023683e-01 -4.98262404e-02 1.21691875e-01 -0.42184665 0.90678658 581.75 1.10487141e-01 -7.12334195e-02 1.31459531e-01 -0.57265544 0.89214543 582.00 1.04220431e-01 -1.04565275e-01 1.47633990e-01 -0.78704983 0.90918182 582.25 7.28731450e-02 -1.23185371e-01 1.43126276e-01 -1.03659616 0.88073186 582.50 3.81848308e-02 -1.38590091e-01 1.43754286e-01 -1.30194346 0.91304226 582.75 1.48437484e-02 -1.25053086e-01 1.25930977e-01 -1.45264956 0.88509688 583.00 -1.10141444e-02 -1.14166294e-01 1.14696356e-01 -1.66697325 0.90625244 583.25 -2.30101667e-02 -1.01278574e-01 1.03859604e-01 -1.79420072 0.86739144 583.50 -2.87539150e-02 -8.47358296e-02 8.94815537e-02 -1.89793949 0.89245887 583.75 -3.32362238e-02 -7.02226804e-02 7.76908709e-02 -2.01285471 0.82170517 584.00 -3.71296178e-02 -5.52979382e-02 6.66068352e-02 -2.16210088 0.81378360 584.25 -3.33455035e-02 -4.18712548e-02 5.35268586e-02 -2.24332713 0.69642597 584.50 -3.57197156e-02 -3.36029715e-02 4.90413884e-02 -2.38671966 0.75034522 584.75 -3.80785718e-02 -2.74464353e-02 4.69391568e-02 -2.51705329 0.68258338 585.00 -3.67349028e-02 -1.93706109e-02 4.15291903e-02 -2.65633800 0.65106674 585.25 -3.54046672e-02 -8.06599999e-03 3.63118551e-02 -2.91759280 0.59827882 585.50 -3.58276529e-02 -2.32686996e-03 3.59031341e-02 -3.07673754 0.61680750 585.75 -2.84556817e-02 2.83969966e-03 2.85970228e-02 3.04212820 0.36095899 586.00 -2.41435831e-02 1.06724698e-02 2.63972388e-02 2.72537655 0.35295627 586.25 -2.36463689e-02 1.69493529e-02 2.90934928e-02 2.51969046 0.38148747 586.50 -2.20172458e-02 2.27974354e-02 3.16935668e-02 2.33878701 0.51532764 586.75 -1.86704738e-02 2.56989413e-02 3.17651094e-02 2.19909194 0.36324113 587.00 -1.21545681e-02 3.13359440e-02 3.36106369e-02 1.94081047 0.40761505 587.25 -7.98922148e-03 3.90390742e-02 3.98481740e-02 1.77265594 0.43918621 587.50 1.62689794e-03 3.49159155e-02 3.49537974e-02 1.52423526 0.38471667 587.75 1.49209593e-02 2.56843173e-02 2.97038580e-02 1.04451200 0.43615251 588.00 1.04686111e-02 2.13104449e-02 2.37429333e-02 1.11417867 0.39286062 588.25 7.09286739e-03 1.87182416e-02 2.00170262e-02 1.20858631 0.33425214 588.50 7.14105076e-03 1.68476353e-02 1.82985634e-02 1.16989106 0.34645298 588.75 9.72097456e-03 1.95220273e-02 2.18084135e-02 1.10879084 0.49042897 589.00 7.52812966e-03 1.96246467e-02 2.10190269e-02 1.20450221 0.50706209 589.25 -9.24493333e-04 1.79605820e-02 1.79843597e-02 1.62222440 0.47365120 589.50 -6.96855591e-04 2.12776548e-02 2.12890630e-02 1.60353521 0.56503564 589.75 3.19766857e-05 2.36508140e-02 2.36508357e-02 1.56944429 0.62794390 590.00 -4.86522617e-04 2.74491357e-02 2.74534470e-02 1.58851899 0.63105961 590.25 -7.42392787e-04 3.41505892e-02 3.41586576e-02 1.59253170 0.78299138 590.50 8.67534565e-04 3.73637392e-02 3.73738093e-02 1.54758188 0.81539159 590.75 3.09393033e-03 4.06034636e-02 4.07211697e-02 1.49474461 0.89138291 591.00 1.94041348e-03 4.31419153e-02 4.31855307e-02 1.52584917 0.87279741 591.25 1.91151099e-03 5.11560808e-02 5.11917813e-02 1.53344745 0.86485691 591.50 7.01448991e-03 5.53468624e-02 5.57895890e-02 1.44473152 0.82288637 591.75 1.83038139e-02 6.04993183e-02 6.32075717e-02 1.27700559 0.88911973 592.00 2.21239144e-02 6.07141084e-02 6.46194286e-02 1.22135549 0.89102418 592.25 2.69325939e-02 6.00935333e-02 6.58528462e-02 1.14945869 0.92245547 592.50 2.55995351e-02 5.90129732e-02 6.43262560e-02 1.16149985 0.86192954 592.75 2.72993982e-02 6.28710826e-02 6.85421780e-02 1.16114872 0.85857195 593.00 2.58996555e-02 6.93473988e-02 7.40260351e-02 1.21336160 0.86264970 593.25 2.84879049e-02 7.90905385e-02 8.40647013e-02 1.22506938 0.88266892 593.50 3.98634817e-02 7.91070834e-02 8.85834511e-02 1.10401925 0.83100046 593.75 5.91056351e-02 7.96209781e-02 9.91613647e-02 0.93221730 0.84403665 594.00 7.89171637e-02 8.61120376e-02 1.16804117e-01 0.82896815 0.86206754 594.25 9.27119172e-02 8.55519026e-02 1.26153191e-01 0.74525447 0.90065731 594.50 1.01041347e-01 6.65287876e-02 1.20976995e-01 0.58227952 0.87589172 594.75 1.00961816e-01 5.73088321e-02 1.16093026e-01 0.51627696 0.89084731 595.00 1.02424461e-01 4.48549654e-02 1.11815644e-01 0.41277311 0.85116356 595.25 1.03612087e-01 3.97224902e-02 1.10965494e-01 0.36609458 0.87963527 595.50 1.00523874e-01 2.49570140e-02 1.03575585e-01 0.24334931 0.85047222 595.75 9.60160950e-02 1.14841651e-02 9.67004475e-02 0.11904116 0.85466911 596.00 7.63838177e-02 1.86825134e-02 7.86353859e-02 0.23987793 0.76205612 596.25 5.84831154e-02 2.39009029e-02 6.31785403e-02 0.38796701 0.71541890 596.50 5.41408635e-02 3.56595763e-02 6.48293027e-02 0.58242814 0.65063474 596.75 5.44767764e-02 4.35626965e-02 6.97526178e-02 0.67453132 0.65402496 597.00 3.26740746e-02 6.03028109e-02 6.85858888e-02 1.07424470 0.57787398 597.25 1.74371156e-02 7.91339150e-02 8.10322745e-02 1.35391272 0.64495855 597.50 3.74611161e-03 1.16030886e-01 1.16091343e-01 1.53852207 0.68996945 597.75 4.63028282e-03 1.66201543e-01 1.66266029e-01 1.54294409 0.77507637 598.00 4.24649010e-02 2.49000086e-01 2.52595152e-01 1.40187972 0.81749666 598.25 7.13038965e-02 3.14624156e-01 3.22602860e-01 1.34792908 0.85096620 598.50 1.28297955e-01 4.06920735e-01 4.26667142e-01 1.26537189 0.89456286 598.75 1.86751673e-01 4.41279710e-01 4.79170084e-01 1.17044725 0.86190055 599.00 3.92497554e-01 4.79582428e-01 6.19720611e-01 0.88492703 0.82952833 599.25 5.26689555e-01 4.49856248e-01 6.92656142e-01 0.70688126 0.81608769 599.50 7.63522030e-01 2.90345432e-01 8.16863735e-01 0.36338396 0.79748139 599.75 8.66762377e-01 1.42729117e-01 8.78435325e-01 0.16320463 0.80989417 600.00 8.91179050e-01 8.31281476e-04 8.91179438e-01 0.00093279 0.80899099 600.25 9.06071327e-01 -2.85319077e-02 9.06520446e-01 -0.03147929 0.79043450 600.50 1.03486718e+00 -2.09116612e-01 1.05578399e+00 -0.19938608 0.79391275 600.75 1.04591441e+00 -3.31085858e-01 1.09706645e+00 -0.30657172 0.78387772 601.00 9.84070945e-01 -6.94946610e-01 1.20471840e+00 -0.61487202 0.77299261 601.25 8.21818585e-01 -8.31167151e-01 1.16885612e+00 -0.79105367 0.76857720 601.50 6.57999475e-01 -9.92098420e-01 1.19047158e+00 -0.98516970 0.77280588 601.75 6.07610545e-01 -1.10330572e+00 1.25955313e+00 -1.06740188 0.75644676 602.00 3.35414164e-01 -1.44733610e+00 1.48569325e+00 -1.34307042 0.80646856 602.25 -1.96958323e-02 -1.51719740e+00 1.51732524e+00 -1.58377732 0.83947753 602.50 -4.27384484e-01 -1.39307272e+00 1.45715788e+00 -1.86847321 0.91063511 602.75 -4.85064966e-01 -1.08723882e+00 1.19053613e+00 -1.99043889 0.89755030 603.00 -5.23621301e-01 -9.09615008e-01 1.04956121e+00 -2.09312014 0.96051165 603.25 -4.73841124e-01 -8.26765051e-01 9.52924897e-01 -2.09122163 0.95393081 603.50 -3.95962162e-01 -7.60462102e-01 8.57373106e-01 -2.05085565 0.96701044 603.75 -3.92384867e-01 -7.50838366e-01 8.47186010e-01 -2.05235663 0.96835162 604.00 -4.28761038e-01 -7.62107690e-01 8.74439340e-01 -2.08326100 0.97349585 604.25 -4.85119276e-01 -7.27022670e-01 8.74015260e-01 -2.15921542 0.97156060 604.50 -5.01922029e-01 -7.03922281e-01 8.64541671e-01 -2.19021791 0.98199529 604.75 -5.31983926e-01 -6.71728303e-01 8.56869774e-01 -2.24061738 0.98259600 605.00 -5.57083917e-01 -6.53639326e-01 8.58828772e-01 -2.27661273 0.98745941 605.25 -5.90065039e-01 -6.21232556e-01 8.56800233e-01 -2.33046948 0.98344574 605.50 -6.15126511e-01 -6.08917589e-01 8.65541019e-01 -2.36126691 0.98326269 605.75 -6.67162836e-01 -6.11091353e-01 9.04731391e-01 -2.40003206 0.96928312 606.00 -7.35643561e-01 -5.98545278e-01 9.48381726e-01 -2.45859287 0.96944483 606.25 -7.83905738e-01 -5.29734475e-01 9.46111421e-01 -2.54731901 0.95945027 606.50 -8.32978817e-01 -4.53477659e-01 9.48417470e-01 -2.64305534 0.95757170 606.75 -8.58356175e-01 -3.42390086e-01 9.24124610e-01 -2.76204315 0.94310671 607.00 -8.67002639e-01 -2.63277678e-01 9.06095311e-01 -2.84677759 0.94417906 607.25 -8.05002807e-01 -1.42772020e-01 8.17565514e-01 -2.96606198 0.93495852 607.50 -7.83677289e-01 -1.18633886e-01 7.92605887e-01 -2.99135233 0.95035452 607.75 -7.66081693e-01 -5.76271031e-02 7.68246082e-01 -3.06651088 0.95172217 608.00 -7.27952683e-01 -9.62870981e-03 7.28016360e-01 -3.12836632 0.95534544 608.25 -6.80216660e-01 2.80049716e-02 6.80792908e-01 3.10044523 0.95341125 608.50 -6.56239932e-01 4.24623051e-02 6.57612269e-01 3.07697727 0.95763882 608.75 -6.01216936e-01 2.50993944e-02 6.01740629e-01 3.09986923 0.96080831 609.00 -5.90860492e-01 1.12707992e-02 5.90967979e-01 3.12251974 0.95990286 609.25 -5.43322086e-01 -2.61961958e-02 5.43953242e-01 -3.09341511 0.93204139 609.50 -5.29590187e-01 -4.88236546e-02 5.31835986e-01 -3.04966113 0.91690383 609.75 -5.75032310e-01 -1.32047242e-01 5.89998841e-01 -2.91587145 0.91645178 610.00 -6.01963437e-01 -1.50230422e-01 6.20426594e-01 -2.89702123 0.90576290 610.25 -6.65846716e-01 -1.60555791e-01 6.84930662e-01 -2.90497925 0.90062845 610.50 -7.22747887e-01 -1.84399906e-01 7.45900686e-01 -2.89178481 0.88212814 610.75 -8.65672225e-01 -1.17837877e-01 8.73655634e-01 -3.00630122 0.89518555 611.00 -9.25560172e-01 -5.23653738e-02 9.27040326e-01 -3.08507595 0.87379862 611.25 -1.13301214e+00 3.60155942e-02 1.13358442e+00 3.10981588 0.86697888 611.50 -1.19335266e+00 1.88274853e-01 1.20811340e+00 2.98511281 0.83810574 611.75 -1.07971204e+00 4.55908217e-01 1.17201979e+00 2.74205374 0.88078982 612.00 -1.02814824e+00 5.77229978e-01 1.17910273e+00 2.63001882 0.86390752 612.25 -9.02788491e-01 7.07585308e-01 1.14704142e+00 2.47682205 0.84242555 612.50 -7.98497877e-01 7.77231299e-01 1.11431026e+00 2.36969001 0.82945515 612.75 -6.02306636e-01 8.88291809e-01 1.07323605e+00 2.16663864 0.82696950 613.00 -4.11417388e-01 8.22877898e-01 9.19995816e-01 2.03442297 0.74363503 613.25 -2.98184118e-01 7.70520348e-01 8.26205407e-01 1.94003763 0.75827098 613.50 -2.50008236e-01 7.89448528e-01 8.28090030e-01 1.87749130 0.79388643 613.75 -1.41389177e-01 8.08961972e-01 8.21224922e-01 1.74382709 0.85322113 614.00 -4.21194577e-02 7.40766633e-01 7.41963107e-01 1.62759445 0.82865966 614.25 4.06302273e-02 6.97391543e-01 6.98574105e-01 1.51260183 0.87970488 614.50 7.19111434e-02 6.22512692e-01 6.26652427e-01 1.45578853 0.88406066 614.75 5.92029412e-02 5.80742730e-01 5.83752607e-01 1.46920380 0.89571418 615.00 4.37934994e-02 5.21480175e-01 5.23315816e-01 1.48701370 0.87342440 615.25 3.72610722e-02 5.12795566e-01 5.14147528e-01 1.49826118 0.90903218 615.50 5.26131069e-02 4.72682595e-01 4.75601698e-01 1.45994514 0.87569180 615.75 8.04390505e-02 4.73133044e-01 4.79922200e-01 1.40239295 0.91030515 616.00 9.85923815e-02 4.62675639e-01 4.73063637e-01 1.36084478 0.92261566 616.25 1.21213554e-01 4.56738908e-01 4.72549633e-01 1.31138701 0.94130134 616.50 1.06387263e-01 4.55012885e-01 4.67284683e-01 1.34111093 0.91943791 616.75 1.16237782e-01 4.40899634e-01 4.55964592e-01 1.31302390 0.91054808 617.00 1.39658460e-01 4.25634340e-01 4.47961021e-01 1.25374653 0.92404613 617.25 1.38691664e-01 4.12066635e-01 4.34780737e-01 1.24613038 0.92287077 617.50 1.17590622e-01 3.98242426e-01 4.15240394e-01 1.28368096 0.88025349 617.75 1.28452459e-01 3.98713961e-01 4.18894805e-01 1.25912896 0.87376048 618.00 2.09856626e-01 3.89602979e-01 4.42527156e-01 1.07671487 0.87269497 618.25 2.38414742e-01 3.63469171e-01 4.34685435e-01 0.99025520 0.89387997 618.50 2.63398807e-01 3.18599180e-01 4.13381626e-01 0.87996161 0.89991470 618.75 2.94983527e-01 2.86506873e-01 4.11219490e-01 0.77082173 0.90549388 619.00 3.01971983e-01 2.43269773e-01 3.87772177e-01 0.67814856 0.92749497 619.25 2.87646119e-01 2.17939813e-01 3.60885095e-01 0.64838961 0.92068779 619.50 2.70395362e-01 1.88687422e-01 3.29721997e-01 0.60926170 0.93319698 619.75 2.57762788e-01 1.75641579e-01 3.11916045e-01 0.59813871 0.94655227 620.00 2.36496872e-01 1.66354459e-01 2.89144560e-01 0.61301144 0.96071761 620.25 2.33362100e-01 1.49143151e-01 2.76950445e-01 0.56867881 0.95067854 620.50 2.06735850e-01 1.34376605e-01 2.46570038e-01 0.57636945 0.95988549 620.75 1.96538671e-01 1.36057431e-01 2.39037808e-01 0.60551783 0.95748010 621.00 1.85983605e-01 1.46754016e-01 2.36910621e-01 0.66804046 0.95849146 621.25 1.82420593e-01 1.43211434e-01 2.31919787e-01 0.66556566 0.94321363 621.50 1.76879051e-01 1.39036203e-01 2.24982809e-01 0.66617826 0.94747501 621.75 1.70108023e-01 1.44380723e-01 2.23119996e-01 0.70377319 0.93946489 622.00 1.62809482e-01 1.59982617e-01 2.28257235e-01 0.77664085 0.92129362 622.25 1.66717002e-01 1.83613704e-01 2.48009175e-01 0.83359154 0.90843380 622.50 1.80547826e-01 2.27025705e-01 2.90065834e-01 0.89894324 0.93406808 622.75 1.89940549e-01 2.26496058e-01 2.95597491e-01 0.87295542 0.93332634 623.00 2.16350530e-01 2.26021481e-01 3.12878989e-01 0.80725626 0.93140179 623.25 2.45673916e-01 2.19585177e-01 3.29504663e-01 0.72938325 0.91297465 623.50 3.13372772e-01 2.32799996e-01 3.90382290e-01 0.63893207 0.89506838 623.75 3.60633095e-01 1.73042903e-01 4.00000095e-01 0.44738253 0.85044386 624.00 4.24598839e-01 1.00569584e-01 4.36346669e-01 0.23257189 0.92456838 624.25 4.09875672e-01 2.52195911e-02 4.10650818e-01 0.06145238 0.89301290 624.50 3.75706793e-01 -8.18872935e-02 3.84527143e-01 -0.21459918 0.90462096 624.75 3.33333570e-01 -1.22273800e-01 3.55052321e-01 -0.35158095 0.92273351 625.00 2.80812368e-01 -1.41376658e-01 3.14392979e-01 -0.46640855 0.93279661 625.25 2.11026181e-01 -1.47428692e-01 2.57424296e-01 -0.60980423 0.90035634 625.50 1.63510408e-01 -1.42395607e-01 2.16822883e-01 -0.71648365 0.93617771 625.75 1.31570791e-01 -1.13917286e-01 1.74034540e-01 -0.71360987 0.92471365 626.00 1.15151352e-01 -9.83564469e-02 1.51439178e-01 -0.70689802 0.93900538 626.25 1.00516126e-01 -8.00713500e-02 1.28510360e-01 -0.67266557 0.87249213 626.50 7.63488282e-02 -7.29603159e-02 1.05604693e-01 -0.76270745 0.84771072 626.75 5.57771587e-02 -6.25797648e-02 8.38291023e-02 -0.84281035 0.74025844 627.00 5.12173426e-02 -4.61302670e-02 6.89290774e-02 -0.73318884 0.64577832 627.25 3.51296628e-02 -1.98462877e-02 4.03480898e-02 -0.51424399 0.29793026 627.50 1.54447969e-02 -3.84757342e-03 1.59168330e-02 -0.24414816 0.07856939 627.75 1.28071723e-02 2.61128282e-02 2.90844196e-02 1.11481367 0.17715464 628.00 2.74407664e-02 4.35820743e-02 5.15013870e-02 1.00887146 0.35851837 628.25 5.60412660e-02 8.30102921e-02 1.00156538e-01 0.97696954 0.64973944 628.50 7.25114913e-02 9.48399725e-02 1.19383989e-01 0.91803748 0.74959679 628.75 1.00825230e-01 9.10297381e-02 1.35838655e-01 0.73438570 0.78867702 629.00 1.23948584e-01 9.98260787e-02 1.59149293e-01 0.67801463 0.82066613 629.25 1.47239950e-01 8.03797570e-02 1.67751329e-01 0.49969765 0.85296206 629.50 1.49315191e-01 6.18611990e-02 1.61622506e-01 0.39277237 0.87380823 629.75 1.58046212e-01 4.15725392e-02 1.63422401e-01 0.25721383 0.92193311 630.00 1.59551179e-01 4.04216069e-02 1.64591875e-01 0.24812508 0.92304765 630.25 1.56768712e-01 2.86680778e-02 1.59368403e-01 0.18087013 0.93631986 630.50 1.51175438e-01 1.95738518e-02 1.52437360e-01 0.12876137 0.93189553 630.75 1.41861876e-01 1.45293064e-02 1.42603971e-01 0.10206281 0.94723164 631.00 1.45701459e-01 1.33055596e-02 1.46307735e-01 0.09106811 0.94979944 631.25 1.42570080e-01 -8.52394341e-04 1.42572628e-01 -0.00597870 0.94911437 631.50 1.36998097e-01 -2.35527832e-03 1.37018341e-01 -0.01719036 0.94656957 631.75 1.31200887e-01 -3.35302655e-03 1.31243725e-01 -0.02555087 0.93070193 632.00 1.26432057e-01 -5.91554964e-03 1.26570371e-01 -0.04675427 0.94399589 632.25 1.19091357e-01 -1.23216922e-02 1.19727088e-01 -0.10309737 0.96408830 632.50 1.17976152e-01 -1.51604387e-02 1.18946254e-01 -0.12780385 0.96220995 632.75 1.10849780e-01 -1.62122379e-02 1.12029060e-01 -0.14522451 0.97215942 633.00 1.10315955e-01 -1.42838414e-02 1.11236855e-01 -0.12876479 0.97646218 633.25 1.10153597e-01 -1.01531914e-02 1.10620533e-01 -0.09191333 0.97993833 633.50 1.08063860e-01 -1.36921952e-02 1.08927839e-01 -0.12603308 0.97228406 633.75 1.08863033e-01 -2.18778963e-02 1.11039643e-01 -0.19832536 0.97054090 634.00 1.09332961e-01 -2.67175579e-02 1.12550096e-01 -0.23967167 0.96773550 634.25 1.07644891e-01 -3.42774514e-02 1.12970644e-01 -0.30827888 0.97240453 634.50 9.57428368e-02 -4.12661977e-02 1.04257325e-01 -0.40695082 0.94615467 634.75 8.37251617e-02 -4.96713741e-02 9.73506451e-02 -0.53545404 0.96315168 635.00 7.67087804e-02 -5.32025958e-02 9.33528424e-02 -0.60639472 0.94419943 635.25 6.41054051e-02 -5.47108315e-02 8.42779808e-02 -0.70649422 0.94121904 635.50 5.11131500e-02 -5.20259140e-02 7.29331875e-02 -0.79424777 0.89022286 635.75 3.15764651e-02 -4.97953167e-02 5.89630962e-02 -1.00566197 0.85295333 636.00 1.78209152e-02 -3.77137496e-02 4.17122515e-02 -1.12936441 0.57324528 636.25 1.15714766e-02 -1.92995160e-02 2.25026752e-02 -1.03069056 0.28812441 636.50 1.90922856e-02 -6.03735758e-03 2.00241118e-02 -0.30627007 0.16105100 636.75 2.53648365e-02 8.64351840e-03 2.67971144e-02 0.32842655 0.30906050 637.00 3.76702653e-02 1.06766437e-02 3.91540497e-02 0.27618061 0.45184947 637.25 4.48416648e-02 1.01149447e-02 4.59683262e-02 0.22185713 0.57189182 637.50 4.46554933e-02 -3.75927948e-03 4.48134496e-02 -0.08398600 0.45360476 637.75 4.24980472e-02 -1.38214031e-02 4.46890948e-02 -0.31443487 0.46745196 638.00 3.32686798e-02 -1.88804838e-02 3.82528133e-02 -0.51619111 0.28853718 638.25 2.54450851e-02 -2.38626321e-02 3.48837723e-02 -0.75331576 0.20438028 638.50 5.24673304e-03 -4.66016865e-03 7.01750522e-03 -0.72625955 0.01329045 638.75 -9.19208756e-04 1.08668985e-03 1.42331991e-03 2.27289341 0.00068920 639.00 -7.27729750e-03 1.14703844e-02 1.35841370e-02 2.13615684 0.04556694 639.25 -2.35510514e-02 1.33901879e-02 2.70914960e-02 2.62461161 0.16884487 639.50 -3.16922240e-02 4.81052870e-02 5.76065595e-02 2.15333967 0.35449687 639.75 -2.42485365e-02 7.43791799e-02 7.82320518e-02 1.88594365 0.44255123 640.00 -2.11602899e-03 9.94294546e-02 9.94519684e-02 1.59207483 0.40312014 640.25 2.52019944e-02 1.13541207e-01 1.16304541e-01 1.35237402 0.39190354 640.50 8.85909704e-02 1.08706347e-01 1.40233483e-01 0.88700172 0.45127061 640.75 1.30628000e-01 8.21470570e-02 1.54310769e-01 0.56137206 0.57722162 641.00 1.37361849e-01 2.54561096e-02 1.39700719e-01 0.18324265 0.73706761 641.25 1.32564628e-01 7.78519409e-03 1.32793033e-01 0.05866016 0.80085215 641.50 1.08061277e-01 2.00663758e-02 1.09908594e-01 0.18360312 0.82774022 641.75 9.71998527e-02 2.24459948e-02 9.97578772e-02 0.22694790 0.86726586 642.00 1.01948896e-01 2.38734473e-02 1.04706823e-01 0.23002595 0.90114939 642.25 1.04366708e-01 1.80600120e-02 1.05917769e-01 0.17134697 0.91732782 642.50 1.04559542e-01 9.87842380e-03 1.05025145e-01 0.09419694 0.91983048 642.75 9.92617199e-02 1.67929056e-03 9.92759238e-02 0.01691619 0.89854179 643.00 8.93590883e-02 -6.51031632e-03 8.95959312e-02 -0.07272718 0.93697615 643.25 8.49297651e-02 -5.74016466e-03 8.51235249e-02 -0.06748456 0.92074304 643.50 7.87127423e-02 -3.71655689e-03 7.88004352e-02 -0.04718167 0.89381494 643.75 7.82467249e-02 -3.92611524e-04 7.82477099e-02 -0.00501757 0.87474192 644.00 7.90641024e-02 3.10516538e-03 7.91250551e-02 0.03925385 0.87725379 644.25 8.82583769e-02 -7.73476527e-04 8.82617661e-02 -0.00876355 0.86333123 644.50 9.70728778e-02 -1.86946996e-02 9.88566407e-02 -0.19025489 0.91426503 644.75 8.80014120e-02 -2.74472803e-02 9.21824371e-02 -0.30233443 0.89017746 645.00 7.64082205e-02 -3.51706861e-02 8.41141683e-02 -0.43138613 0.88496830 645.25 6.30070885e-02 -4.09113659e-02 7.51241177e-02 -0.57589261 0.87775258 645.50 5.41672698e-02 -4.87223759e-02 7.28557687e-02 -0.73252773 0.91498143 645.75 4.77847031e-02 -5.19466327e-02 7.05820834e-02 -0.82710538 0.86781601 646.00 3.66078492e-02 -5.44808333e-02 6.56376098e-02 -0.97915186 0.86955402 646.25 2.60152008e-02 -5.18717380e-02 5.80298878e-02 -1.10592596 0.78269365 646.50 9.74195082e-03 -5.22074696e-02 5.31086197e-02 -1.38631727 0.69640207 646.75 -8.85240633e-03 -4.66396392e-02 4.74723187e-02 -1.75836943 0.67456946 647.00 -1.39484831e-02 -3.82899661e-02 4.07514624e-02 -1.92014062 0.72192611 647.25 -2.19361618e-02 -1.87871816e-02 2.88817137e-02 -2.43336709 0.52678626 647.50 -2.67795225e-02 -7.33824489e-03 2.77667547e-02 -2.87413360 0.57609343 647.75 -2.39725557e-02 1.48987759e-02 2.82251121e-02 2.58551919 0.56641866 648.00 -2.18121883e-02 2.73322716e-02 3.49689094e-02 2.24433971 0.74166392 648.25 -1.02121730e-02 3.90250490e-02 4.03390993e-02 1.82673972 0.75830715 648.50 -1.11858504e-03 4.67966222e-02 4.68099891e-02 1.59469489 0.83882805 648.75 1.43543994e-02 4.92025123e-02 5.12536437e-02 1.28693354 0.83546630 649.00 2.61411535e-02 5.33560872e-02 5.94157550e-02 1.11523099 0.91079613 649.25 3.74121568e-02 4.97631399e-02 6.22578475e-02 0.92614128 0.90321655 649.50 4.46032583e-02 4.89328128e-02 6.62108059e-02 0.83165269 0.85766070 649.75 5.93282935e-02 4.41538236e-02 7.39554362e-02 0.63979729 0.68142738 650.00 6.82954958e-02 4.29983124e-02 8.07039628e-02 0.56189477 0.77548568 650.25 8.04996733e-02 3.44038132e-02 8.75432451e-02 0.40388336 0.93385108 650.50 8.66522312e-02 2.53741474e-02 9.02909549e-02 0.28486350 0.93817653 650.75 9.01843032e-02 9.06163904e-03 9.06384126e-02 0.10014300 0.94647034 651.00 9.10729872e-02 1.13801909e-03 9.10800971e-02 0.01249503 0.94587333 651.25 9.19964163e-02 -8.97180921e-03 9.24328620e-02 -0.09721604 0.94081103 651.50 9.44350893e-02 -1.73754688e-02 9.60202739e-02 -0.18195867 0.94221316 651.75 9.64426343e-02 -3.23778546e-02 1.01732528e-01 -0.32389826 0.93743682 652.00 9.59286818e-02 -3.88049718e-02 1.03480133e-01 -0.38439596 0.90916200 652.25 8.75755004e-02 -4.51265335e-02 9.85183856e-02 -0.47580243 0.92271541 652.50 8.75547286e-02 -5.35566987e-02 1.02636010e-01 -0.54897366 0.90175150 652.75 8.85697909e-02 -7.08251208e-02 1.13405492e-01 -0.67452947 0.89682534 653.00 7.71690560e-02 -8.58752044e-02 1.15453947e-01 -0.83874495 0.87734561 653.25 5.54558299e-02 -9.93395533e-02 1.13770365e-01 -1.06164487 0.90811478 653.50 4.06252699e-02 -1.00454530e-01 1.08358318e-01 -1.18649014 0.87289364 653.75 1.15523511e-02 -1.07909818e-01 1.08526428e-01 -1.46414691 0.87130308 654.00 -8.36105805e-05 -9.76147965e-02 9.76148323e-02 -1.57165286 0.83038432 654.25 -1.82133584e-02 -8.20702547e-02 8.40669562e-02 -1.78918106 0.78858698 654.50 -2.11281050e-02 -6.51675993e-02 6.85070275e-02 -1.88431517 0.70791539 654.75 -2.07674298e-02 -4.75099915e-02 5.18506069e-02 -1.98288534 0.71623377 655.00 -1.30707807e-02 -4.18468676e-02 4.38406847e-02 -1.87354261 0.54255544 655.25 3.71233699e-03 -3.59114917e-02 3.61028625e-02 -1.46778759 0.46939970 655.50 1.49345627e-02 -3.56584945e-02 3.86596611e-02 -1.17417010 0.47040385 655.75 2.83225502e-02 -4.74040893e-02 5.52205988e-02 -1.03223875 0.71650126 656.00 2.66955239e-02 -5.23800593e-02 5.87904891e-02 -1.09945815 0.77739482 656.25 2.10045011e-02 -5.82752208e-02 6.19450597e-02 -1.22485462 0.82195372 656.50 1.74293713e-02 -6.34221815e-02 6.57735212e-02 -1.30260205 0.77126932 656.75 7.12052659e-03 -6.81746075e-02 6.85454521e-02 -1.46672822 0.80566440 657.00 -4.67923584e-03 -5.43467658e-02 5.45478341e-02 -1.65668413 0.58104415 657.25 -1.62151154e-02 -4.29692234e-02 4.59269434e-02 -1.93163951 0.52165424 657.50 -2.13619844e-02 -2.82050467e-02 3.53816201e-02 -2.21900497 0.43511920 657.75 -1.62099434e-02 -1.68617822e-02 2.33897833e-02 -2.33648719 0.25098633 658.00 9.47937170e-03 -4.12805037e-03 1.03392112e-02 -0.41071137 0.06288048 658.25 2.45706496e-02 -4.77128122e-03 2.50296214e-02 -0.19179917 0.29338533 658.50 2.81803071e-02 -1.19692442e-02 3.06168665e-02 -0.40164862 0.35675580 658.75 2.93557839e-02 -1.87848341e-02 3.48515716e-02 -0.56924389 0.43095597 659.00 3.51677567e-02 -2.61790685e-02 4.38419290e-02 -0.63991095 0.43509671 659.25 3.45790429e-02 -2.16062749e-02 4.07742728e-02 -0.55848229 0.35854090 659.50 3.17999143e-02 -1.69655592e-02 3.60425408e-02 -0.49009454 0.22601331 659.75 2.83446037e-02 -1.64812101e-02 3.27879070e-02 -0.52667445 0.15114827 660.00 2.39571623e-02 3.19930657e-02 3.99687613e-02 0.92804855 0.15205941 660.25 2.39930231e-02 7.32695805e-02 7.70979675e-02 1.25433900 0.41803108 660.50 6.51002464e-02 1.15840762e-01 1.32880112e-01 1.05880161 0.71528473 660.75 9.83217191e-02 1.30572392e-01 1.63451247e-01 0.92537452 0.83052279 661.00 1.68191658e-01 1.44678505e-01 2.21856493e-01 0.71038610 0.88699514 661.25 2.05797333e-01 1.23998089e-01 2.40266661e-01 0.54227423 0.89326330 661.50 2.50746090e-01 6.97365697e-02 2.60262926e-01 0.27126108 0.94521734 661.75 2.51536609e-01 4.01436362e-02 2.54719802e-01 0.15825899 0.94753201 662.00 2.58902548e-01 -9.76320104e-03 2.59086567e-01 -0.03769209 0.95984146 662.25 2.59069993e-01 -2.90661373e-02 2.60695420e-01 -0.11172692 0.96399137 662.50 2.42445214e-01 -5.14368435e-02 2.47841543e-01 -0.20905875 0.96931164 662.75 2.35579947e-01 -5.86934470e-02 2.42781449e-01 -0.24417332 0.96023298 663.00 2.15347817e-01 -6.41458589e-02 2.24698405e-01 -0.28950240 0.96565729 663.25 2.16664600e-01 -6.46141395e-02 2.26094087e-01 -0.28982476 0.96912800 663.50 2.22921520e-01 -7.68397684e-02 2.35793032e-01 -0.33194031 0.97579700 663.75 2.24561543e-01 -8.02637665e-02 2.38474650e-01 -0.34327358 0.96620435 664.00 2.32005810e-01 -9.19543079e-02 2.49564202e-01 -0.37735142 0.95991039 664.25 2.25244444e-01 -9.64933867e-02 2.45042921e-01 -0.40474195 0.94623846 664.50 2.13159447e-01 -1.12305279e-01 2.40934484e-01 -0.48490433 0.94174914 664.75 2.13269648e-01 -1.19116566e-01 2.44279960e-01 -0.50936523 0.93039034 665.00 2.03629508e-01 -1.36279413e-01 2.45024601e-01 -0.58979017 0.92198434 665.25 2.03590499e-01 -1.35827949e-01 2.44741340e-01 -0.58834580 0.90545762 665.50 2.13417847e-01 -1.34484997e-01 2.52256599e-01 -0.56229325 0.88947854 665.75 2.10168906e-01 -1.75769824e-01 2.73981751e-01 -0.69650213 0.83743035 666.00 2.16883992e-01 -2.42291936e-01 3.25183100e-01 -0.84067558 0.90787741 666.25 1.60428335e-01 -2.64127597e-01 3.09031776e-01 -1.02496106 0.85331073 666.50 8.87919793e-02 -2.73424866e-01 2.87480735e-01 -1.25679965 0.90296933 666.75 4.92065342e-02 -2.56684816e-01 2.61358715e-01 -1.38139392 0.85644709 667.00 1.15768581e-02 -2.32528839e-01 2.32816848e-01 -1.52105064 0.85410694 667.25 -1.62314286e-02 -1.81322404e-01 1.82047449e-01 -1.66007531 0.79035948 667.50 -2.85996568e-02 -1.31841357e-01 1.34907686e-01 -1.78441149 0.72489815 667.75 1.02325245e-02 -8.32062513e-02 8.38330771e-02 -1.44843288 0.39513232 668.00 4.36692963e-02 -4.25854327e-02 6.09961189e-02 -0.77283298 0.28728796 668.25 1.08280904e-01 -2.57868655e-02 1.11309104e-01 -0.23379298 0.54581148 668.50 1.52192738e-01 -2.85663310e-02 1.54850460e-01 -0.18553959 0.75310748 668.75 2.03155382e-01 -8.12365556e-02 2.18795538e-01 -0.38039775 0.79911157 669.00 2.47852864e-01 -1.27259937e-01 2.78614669e-01 -0.47434925 0.88168480 669.25 2.66741649e-01 -2.22851239e-01 3.47582769e-01 -0.69599041 0.86703597 669.50 2.25421378e-01 -2.85330699e-01 3.63632239e-01 -0.90216091 0.88836117 669.75 1.49955652e-01 -3.90560267e-01 4.18358721e-01 -1.20420218 0.86393180 670.00 7.76946201e-02 -4.34491779e-01 4.41383688e-01 -1.39384927 0.84501193 670.25 -7.62179521e-02 -3.88999201e-01 3.96395704e-01 -1.76427869 0.78681410 670.50 -1.29907053e-01 -3.16626291e-01 3.42239756e-01 -1.96013761 0.73194500 670.75 -1.45987117e-01 -2.15450690e-01 2.60252259e-01 -2.16632279 0.62433877 671.00 -1.40520249e-01 -1.72934547e-01 2.22827956e-01 -2.25315095 0.57775559 671.25 -1.12073446e-01 -1.07285752e-01 1.55147317e-01 -2.37801685 0.50541110 671.50 -1.02718107e-01 -6.89370630e-02 1.23706621e-01 -2.55050735 0.42787126 671.75 -8.82443721e-02 -6.01305620e-02 1.06783677e-01 -2.54345273 0.38171330 672.00 -6.77617201e-02 -6.01094595e-02 9.05803391e-02 -2.41596672 0.26588155 672.25 -3.49857629e-02 -5.17630735e-02 6.24773509e-02 -2.16515211 0.15999218 672.50 -4.12755078e-02 -2.79137661e-02 4.98281636e-02 -2.54696473 0.10055899 672.75 -1.72298721e-02 2.28511706e-02 2.86189534e-02 2.21685502 0.03834684 673.00 2.06318968e-02 2.04384195e-02 2.90414214e-02 0.78068732 0.04127920 673.25 9.78753534e-02 5.69656417e-03 9.80409897e-02 0.05813665 0.32468220 673.50 1.21958949e-01 -1.05878946e-02 1.22417681e-01 -0.08659811 0.49958284 673.75 1.34920310e-01 -4.18837657e-02 1.41271865e-01 -0.30100099 0.71644981 674.00 1.46947969e-01 -6.93774995e-02 1.62502132e-01 -0.44109826 0.79558359 674.25 1.38437177e-01 -1.23475794e-01 1.85502355e-01 -0.72833668 0.85892333 674.50 1.17301805e-01 -1.31282528e-01 1.76053445e-01 -0.84158035 0.83436019 674.75 9.78512425e-02 -1.48674957e-01 1.77986260e-01 -0.98870923 0.88975938 675.00 9.33509886e-02 -1.51770380e-01 1.78181523e-01 -1.01936201 0.88322080 675.25 8.53587650e-02 -1.63428903e-01 1.84377669e-01 -1.08946901 0.89429956 675.50 8.89323505e-02 -1.69338621e-01 1.91270833e-01 -1.08721242 0.91123364 675.75 9.43094478e-02 -1.82302561e-01 2.05252274e-01 -1.09338595 0.92486402 676.00 9.05142290e-02 -1.88973434e-01 2.09532299e-01 -1.12410683 0.90135595 676.25 7.36783760e-02 -1.98172825e-01 2.11426043e-01 -1.21484419 0.85498284 676.50 7.33096316e-02 -2.05768340e-01 2.18437433e-01 -1.22854437 0.84890545 676.75 7.35993489e-02 -2.02765821e-01 2.15710089e-01 -1.22260772 0.89368392 677.00 7.83390249e-02 -2.19139607e-01 2.32721229e-01 -1.22746938 0.87635311 677.25 9.07241762e-02 -2.52896977e-01 2.68677794e-01 -1.22635693 0.90358997 677.50 8.49323176e-02 -2.77490652e-01 2.90197451e-01 -1.27377759 0.84556482 677.75 4.88191451e-02 -3.20594257e-01 3.24289973e-01 -1.41968019 0.85158319 678.00 2.91327914e-02 -3.25020549e-01 3.26323577e-01 -1.48140153 0.83059864 678.25 1.49863118e-02 -3.47109743e-01 3.47433106e-01 -1.52764856 0.84746690 678.50 -1.81987819e-02 -3.41659229e-01 3.42143573e-01 -1.62401192 0.77206313 678.75 -3.86501676e-02 -3.46680694e-01 3.48828524e-01 -1.68182420 0.71273668 679.00 -4.36204333e-02 -3.00427495e-01 3.03577703e-01 -1.71498328 0.59231421 679.25 -1.67316608e-02 -2.36595360e-01 2.37186241e-01 -1.64139725 0.47911163 679.50 4.13580706e-02 -2.23709637e-01 2.27500531e-01 -1.38798650 0.31086888 679.75 8.17814414e-02 -1.83260177e-01 2.00680085e-01 -1.15105805 0.13400551 680.00 -6.56178080e-02 -1.79564385e-01 1.91178098e-01 -1.92114859 0.06823530 680.25 -2.61949470e-01 -1.99011223e-01 3.28972631e-01 -2.49189252 0.14427347 680.50 -5.40729653e-01 -2.21423837e-01 5.84309056e-01 -2.75293139 0.38939886 680.75 -6.27604508e-01 -1.92878092e-01 6.56573969e-01 -2.84342997 0.45399743 681.00 -5.48645128e-01 -1.56652443e-01 5.70571173e-01 -2.86346709 0.38164040 681.25 -5.87555467e-01 -1.39863570e-01 6.03972884e-01 -2.90789874 0.45233199 681.50 -6.01283776e-01 7.84861715e-02 6.06384580e-01 3.01179551 0.43106877 681.75 -6.14385002e-01 1.97266512e-01 6.45277466e-01 2.83091067 0.46995257 682.00 -5.15385883e-01 2.08444757e-01 5.55942286e-01 2.75726107 0.36667819 682.25 -5.50257611e-01 2.30415871e-01 5.96552522e-01 2.74503466 0.44319074 682.50 -5.01446781e-01 4.13293706e-01 6.49815791e-01 2.45226730 0.46901784 682.75 -5.48210986e-01 5.40097831e-01 7.69571928e-01 2.36364918 0.54844585 683.00 -3.39994688e-01 8.12805725e-01 8.81050245e-01 1.96697632 0.44593858 683.25 -5.48578733e-02 8.78230312e-01 8.79941969e-01 1.63317938 0.44016958 683.50 1.25932401e-01 8.21153096e-01 8.30753499e-01 1.41862152 0.47780119 683.75 2.18021363e-01 5.53446815e-01 5.94841737e-01 1.19553042 0.32300472 684.00 4.57623199e-01 2.66736786e-01 5.29686233e-01 0.52773186 0.36097067 684.25 4.57763520e-01 4.68459418e-02 4.60154303e-01 0.10198153 0.40745765 684.50 4.64543962e-01 3.06211494e-02 4.65552089e-01 0.06582136 0.60522560 684.75 3.27288654e-01 -6.70931644e-02 3.34094830e-01 -0.20219564 0.48698533 685.00 2.03180745e-01 -1.38767224e-01 2.46046251e-01 -0.59920768 0.54785630 685.25 1.89535449e-01 -1.38293784e-01 2.34624929e-01 -0.63034679 0.55300109 685.50 1.35809338e-01 -1.28481477e-01 1.86953648e-01 -0.75767876 0.48119429 685.75 8.73198994e-02 -1.38477805e-01 1.63709704e-01 -1.00820190 0.45908546 686.00 6.84642836e-02 -1.93034144e-01 2.04815865e-01 -1.22996325 0.63574649 686.25 4.99762953e-02 -2.33059410e-01 2.38357543e-01 -1.35955944 0.64905550 686.50 -5.42982995e-03 -2.79184839e-01 2.79237636e-01 -1.59024275 0.72163185 686.75 -6.48326872e-02 -2.85600140e-01 2.92866381e-01 -1.79401843 0.76647031 687.00 -1.21170044e-01 -3.03367446e-01 3.26671068e-01 -1.95079982 0.80789121 687.25 -2.04541407e-01 -2.79874755e-01 3.46651216e-01 -2.20191658 0.79379817 687.50 -2.61821983e-01 -2.51916322e-01 3.63335361e-01 -2.37547363 0.82494922 687.75 -3.18855422e-01 -1.98936781e-01 3.75825255e-01 -2.58377823 0.81646155 688.00 -3.56286256e-01 -1.44521953e-01 3.84482108e-01 -2.75623851 0.89966330 688.25 -3.62955868e-01 -1.01411628e-01 3.76857109e-01 -2.86913592 0.88249033 688.50 -3.67995893e-01 -3.92794824e-02 3.70086280e-01 -3.03525636 0.89499378 688.75 -3.62030790e-01 -3.36203422e-03 3.62046401e-01 -3.13230632 0.91871679 689.00 -3.55782794e-01 2.23720335e-02 3.56485490e-01 3.07879418 0.92977926 689.25 -3.39780000e-01 8.04826993e-02 3.49181777e-01 2.90901206 0.90924051 689.50 -3.36237382e-01 9.85377318e-02 3.50378741e-01 2.85651492 0.93745038 689.75 -3.18574234e-01 1.14542684e-01 3.38540351e-01 2.79643740 0.92141575 690.00 -3.04024939e-01 1.28599513e-01 3.30104527e-01 2.74142571 0.94767468 690.25 -2.98829766e-01 1.26612018e-01 3.24545578e-01 2.74082974 0.95415675 690.50 -2.88141064e-01 1.33889845e-01 3.17729072e-01 2.70660824 0.95089423 690.75 -2.69222384e-01 1.51022663e-01 3.08688414e-01 2.63037474 0.94272938 691.00 -2.56565218e-01 1.70339118e-01 3.07962865e-01 2.55549308 0.94072532 691.25 -2.33881459e-01 1.75361797e-01 2.92322248e-01 2.49822646 0.96244594 691.50 -2.28320446e-01 1.71084807e-01 2.85307268e-01 2.49852764 0.96343627 691.75 -2.05340529e-01 1.64388239e-01 2.63036548e-01 2.46650789 0.95033596 692.00 -2.01349228e-01 1.61467915e-01 2.58095717e-01 2.46567620 0.96481343 692.25 -2.01530771e-01 1.58633970e-01 2.56474926e-01 2.47473933 0.97116295 692.50 -2.01686557e-01 1.55127207e-01 2.54444331e-01 2.48594780 0.97482827 692.75 -2.00102843e-01 1.59931265e-01 2.56162365e-01 2.46731204 0.97738557 693.00 -2.03236904e-01 1.64269174e-01 2.61322790e-01 2.46183266 0.97792941 693.25 -2.01989274e-01 1.71628247e-01 2.65058337e-01 2.43727864 0.98391040 693.50 -2.01231699e-01 1.76239372e-01 2.67496753e-01 2.42230791 0.98333883 693.75 -1.91908765e-01 1.91647623e-01 2.71215386e-01 2.35687533 0.98485534 694.00 -1.84016658e-01 1.91795975e-01 2.65796589e-01 2.33549746 0.98323201 694.25 -1.70115710e-01 1.88909661e-01 2.54216866e-01 2.30389509 0.97756003 694.50 -1.68443358e-01 1.87056050e-01 2.51720343e-01 2.30388579 0.97316384 694.75 -1.69084779e-01 1.70907098e-01 2.40414015e-01 2.35083465 0.97294749 695.00 -1.75638122e-01 1.74412032e-01 2.47524356e-01 2.35969709 0.97986615 695.25 -1.93274292e-01 1.81701973e-01 2.65274498e-01 2.38704617 0.98464534 695.50 -2.02613151e-01 1.90881576e-01 2.78366422e-01 2.38599947 0.97326769 695.75 -2.11940582e-01 2.34051884e-01 3.15751635e-01 2.30665730 0.97692258 696.00 -1.93680415e-01 2.51113994e-01 3.17128272e-01 2.22778114 0.97773714 696.25 -1.63490065e-01 2.80619942e-01 3.24771540e-01 2.09832581 0.97789103 696.50 -1.29527931e-01 2.90092021e-01 3.17696184e-01 1.99074114 0.96815673 696.75 -9.08009850e-02 2.85379904e-01 2.99477058e-01 1.87884366 0.96588802 697.00 -7.84660879e-02 2.63686945e-01 2.75114034e-01 1.86002494 0.94926173 697.25 -6.35046626e-02 2.27146523e-01 2.35856705e-01 1.84341159 0.93286287 697.50 -6.73717442e-02 2.04405562e-01 2.15222177e-01 1.88918167 0.91654991 697.75 -8.68116206e-02 1.90606367e-01 2.09444610e-01 1.99817301 0.90641579 698.00 -9.83219427e-02 1.87538834e-01 2.11749896e-01 2.05367490 0.91061899 698.25 -1.16348278e-01 1.80599461e-01 2.14832696e-01 2.14310730 0.92617828 698.50 -1.36694650e-01 2.07232722e-01 2.48255570e-01 2.15390392 0.93746964 698.75 -1.50777651e-01 2.34547987e-01 2.78830877e-01 2.14212416 0.94728282 699.00 -1.28084729e-01 2.73945351e-01 3.02409909e-01 2.00815334 0.93356381 699.25 -1.16405421e-01 3.00099770e-01 3.21885218e-01 1.94081885 0.95505435 699.50 -8.42023247e-02 3.32789258e-01 3.43276451e-01 1.81861528 0.94760749 699.75 -5.95451794e-02 3.40708277e-01 3.45872459e-01 1.74381766 0.95846883 700.00 -3.94811466e-03 3.34038764e-01 3.34062096e-01 1.58261511 0.93470267 700.25 2.48956255e-02 3.20534492e-01 3.21499849e-01 1.49328284 0.94741341 700.50 4.28353536e-02 2.88660244e-01 2.91821185e-01 1.42347773 0.95804672 700.75 5.57165787e-02 2.69908684e-01 2.75599410e-01 1.36722817 0.96391643 701.00 6.47390459e-02 2.45639693e-01 2.54027563e-01 1.31310325 0.97232001 701.25 6.34819195e-02 2.36025448e-01 2.44413515e-01 1.30805205 0.97574983 701.50 6.73104775e-02 2.12656609e-01 2.23055002e-01 1.26425157 0.97206051 701.75 6.26178887e-02 2.08407011e-01 2.17610850e-01 1.27891793 0.97864556 702.00 5.51126664e-02 2.00575994e-01 2.08009941e-01 1.30264210 0.97765472 702.25 5.43048182e-02 1.94551000e-01 2.01987883e-01 1.29859552 0.97911923 702.50 4.90706152e-02 1.85210924e-01 1.91601178e-01 1.31180246 0.97728546 702.75 4.72156578e-02 1.83806059e-01 1.89773511e-01 1.31935518 0.97625937 703.00 4.57269338e-02 1.77328037e-01 1.83128875e-01 1.31842785 0.97648358 703.25 4.80575523e-02 1.72978147e-01 1.79529852e-01 1.29980618 0.96818337 703.50 5.60714825e-02 1.70969939e-01 1.79929795e-01 1.25388859 0.96673959 703.75 5.73448383e-02 1.71388178e-01 1.80727248e-01 1.24791484 0.97477243 704.00 5.38351353e-02 1.65776098e-01 1.74298412e-01 1.25679412 0.97317379 704.25 5.67530815e-02 1.55895956e-01 1.65904977e-01 1.22166481 0.95992044 704.50 6.48902001e-02 1.37019429e-01 1.51608252e-01 1.12850401 0.95993898 704.75 6.21839477e-02 1.33493351e-01 1.47266147e-01 1.13486419 0.95458932 705.00 6.24726286e-02 1.32339862e-01 1.46344349e-01 1.12974781 0.95172185 705.25 5.62930639e-02 1.30590778e-01 1.42207103e-01 1.16380013 0.93070776 705.50 4.44676161e-02 1.18671508e-01 1.26729222e-01 1.21227834 0.92266467 705.75 3.96774050e-02 1.20568285e-01 1.26929145e-01 1.25287270 0.91787452 706.00 3.72279294e-02 1.22204543e-01 1.27749243e-01 1.27509157 0.91180419 706.25 2.87950540e-02 1.22767123e-01 1.26098857e-01 1.34041066 0.91209130 706.50 2.62693940e-02 1.23316720e-01 1.26083680e-01 1.36090984 0.90500003 706.75 3.17720059e-02 1.21928356e-01 1.25999938e-01 1.31588572 0.85660791 707.00 2.63547341e-02 1.06287673e-01 1.09506353e-01 1.32774175 0.72861837 707.25 2.06946824e-02 1.08642186e-01 1.10595635e-01 1.38256654 0.76859135 707.50 1.32206290e-02 1.16298026e-01 1.17047067e-01 1.45760337 0.88375433 707.75 8.07560097e-03 1.16874603e-01 1.17153268e-01 1.50180969 0.89631610 708.00 7.93579993e-03 1.22042687e-01 1.22300427e-01 1.50586295 0.87094649 708.25 1.34221938e-02 1.27492321e-01 1.28196908e-01 1.46590426 0.85900202 708.50 2.35770403e-02 1.34003560e-01 1.36061864e-01 1.39663545 0.89953650 708.75 9.61142453e-03 1.31692237e-01 1.32042511e-01 1.49794151 0.87704250 709.00 9.75282301e-03 1.30436804e-01 1.30800908e-01 1.49616471 0.91296023 709.25 1.78154255e-02 1.30868584e-01 1.32075644e-01 1.43549585 0.91774666 709.50 1.43577631e-02 1.33547119e-01 1.34316710e-01 1.46369686 0.92975852 709.75 1.99427214e-02 1.32172057e-01 1.33668114e-01 1.42104141 0.90523883 710.00 2.33482824e-02 1.27636315e-01 1.29754273e-01 1.38986853 0.89868080 710.25 2.25432826e-02 1.37096980e-01 1.38938049e-01 1.40782162 0.90528448 710.50 2.91212180e-02 1.45389967e-01 1.48277739e-01 1.37311492 0.91631044 710.75 4.09577348e-02 1.45271370e-01 1.50934777e-01 1.29599005 0.92794354 711.00 4.29842832e-02 1.41441576e-01 1.47828847e-01 1.27576418 0.93615178 711.25 6.14100476e-02 1.39429979e-01 1.52354563e-01 1.15592384 0.94169520 711.50 7.10383491e-02 1.40303992e-01 1.57263019e-01 1.10210760 0.94765772 711.75 8.02702876e-02 1.20137272e-01 1.44486273e-01 0.98176423 0.95735433 712.00 7.85714902e-02 1.12442298e-01 1.37174157e-01 0.96089523 0.95631883 712.25 7.82655976e-02 1.04163390e-01 1.30290121e-01 0.92641684 0.95086208 712.50 8.40452043e-02 1.00528321e-01 1.31032590e-01 0.87446568 0.94813684 712.75 8.98474941e-02 9.61867670e-02 1.31622439e-01 0.81946082 0.96787375 713.00 9.18141282e-02 9.15852941e-02 1.29683076e-01 0.78415043 0.96352564 713.25 9.34102572e-02 8.15964156e-02 1.24030042e-01 0.71799533 0.95261095 713.50 9.09568925e-02 7.52843598e-02 1.18071551e-01 0.69140016 0.95068380 713.75 9.05963610e-02 6.86333047e-02 1.13658397e-01 0.64832987 0.94580946 714.00 9.28575375e-02 6.52613432e-02 1.13496983e-01 0.61261037 0.94096902 714.25 9.32512124e-02 4.69629680e-02 1.04409334e-01 0.46653764 0.90762784 714.50 9.30414515e-02 4.09356820e-02 1.01648619e-01 0.41448385 0.91813596 714.75 9.10858389e-02 2.54128353e-02 9.45644872e-02 0.27208000 0.94462940 715.00 8.82093239e-02 2.15192992e-02 9.07962833e-02 0.23928328 0.93469559 715.25 7.61915591e-02 9.40016103e-03 7.67692432e-02 0.12275503 0.91176125 715.50 7.06181527e-02 4.12716045e-03 7.07386524e-02 0.05837693 0.88406576 715.75 6.23429441e-02 -1.27630022e-03 6.23560071e-02 -0.02046939 0.85589452 716.00 5.93384494e-02 -2.46017619e-03 5.93894271e-02 -0.04143634 0.82931173 716.25 5.36400199e-02 -3.60433655e-03 5.37609800e-02 -0.06709406 0.77022595 716.50 4.74020861e-02 -5.16559395e-03 4.76827131e-02 -0.10854566 0.67432833 716.75 3.67823462e-02 -1.11446612e-02 3.84336371e-02 -0.29419711 0.52856677 717.00 2.05273210e-02 -2.35489704e-02 3.12397970e-02 -0.85384605 0.34540559 717.25 -1.66690630e-03 -2.54256292e-02 2.54802119e-02 -1.63626272 0.23195501 717.50 -2.03752998e-02 -1.61998647e-02 2.60305294e-02 -2.46986279 0.22090464 717.75 -1.59114572e-02 6.20172508e-03 1.70773495e-02 2.76994079 0.13476971 718.00 -9.41767851e-03 1.60737574e-02 1.86295020e-02 2.10078663 0.20264685 718.25 -9.48255912e-03 1.94166207e-02 2.16084263e-02 2.02509939 0.27720278 718.50 -9.40774385e-03 1.58153925e-02 1.84019641e-02 2.10741848 0.16602332 718.75 -1.68459103e-02 1.90458751e-02 2.54269552e-02 2.29497669 0.23925480 719.00 -1.70569825e-02 3.60390191e-02 3.98716885e-02 2.01285024 0.41628304 719.25 -1.32782540e-02 3.29222144e-02 3.54990737e-02 1.95416323 0.30790871 719.50 -1.55612447e-02 2.80771519e-02 3.21010715e-02 2.07688256 0.23078822 719.75 -1.60364715e-02 2.82195567e-02 3.24578465e-02 2.08756198 0.32605998 720.00 -2.45051915e-02 4.55966863e-02 5.17644879e-02 2.06394047 0.64943387 720.25 -1.82387458e-02 5.60383768e-02 5.89317531e-02 1.88545222 0.72240643 720.50 -1.54224746e-02 5.85995200e-02 6.05950201e-02 1.82814475 0.67280963 720.75 -8.96812863e-03 5.92186567e-02 5.98938781e-02 1.72109520 0.66132375 721.00 -1.32246525e-02 6.41863385e-02 6.55345518e-02 1.77398828 0.64929015 721.25 -1.35684513e-02 6.58258848e-02 6.72097462e-02 1.77407564 0.66281939 721.50 1.78783969e-03 8.26958168e-02 8.27151406e-02 1.54918022 0.76474284 721.75 2.84601018e-03 9.71039752e-02 9.71456729e-02 1.54149582 0.84860488 722.00 1.73116099e-03 1.14666089e-01 1.14679156e-01 1.55570006 0.84065716 722.25 6.25132294e-04 1.37352132e-01 1.37353555e-01 1.56624505 0.80347549 722.50 2.52974204e-02 1.94281690e-01 1.95921756e-01 1.44131481 0.73625075 722.75 2.29111976e-02 2.44668666e-01 2.45739047e-01 1.47742687 0.67978172 723.00 -6.74875238e-02 3.24305082e-01 3.31252701e-01 1.77596700 0.50754054 723.25 -1.72616610e-01 3.13045515e-01 3.57482851e-01 2.07472187 0.32726627 723.50 -4.50743212e-01 2.02318292e-04 4.50743258e-01 3.14114380 0.47055954 723.75 -4.62300265e-01 -6.84466381e-02 4.67339787e-01 -2.99460381 0.61720651 724.00 -3.63171739e-01 -1.26076727e-01 3.84433418e-01 -2.80745499 0.73571787 724.25 -3.19655140e-01 -1.29245682e-01 3.44795381e-01 -2.75736039 0.77626003 724.50 -2.69983189e-01 -1.39084704e-01 3.03702943e-01 -2.66589025 0.87339869 724.75 -2.60211984e-01 -1.29590736e-01 2.90695778e-01 -2.67953041 0.90573631 725.00 -2.32301290e-01 -1.34471213e-01 2.68414598e-01 -2.61685817 0.92848431 725.25 -2.20112049e-01 -1.23880752e-01 2.52578215e-01 -2.62896949 0.92814797 725.50 -2.25229785e-01 -1.27029507e-01 2.58582582e-01 -2.62806477 0.95408995 725.75 -2.21375893e-01 -1.27547754e-01 2.55491126e-01 -2.61888765 0.95092953 726.00 -2.22768863e-01 -1.25252433e-01 2.55566309e-01 -2.62939094 0.95053041 726.25 -2.24139492e-01 -1.25032375e-01 2.56654645e-01 -2.63275562 0.94668217 726.50 -2.19427316e-01 -1.14080028e-01 2.47310735e-01 -2.66215292 0.94659184 726.75 -2.20631415e-01 -1.06075975e-01 2.44806727e-01 -2.69343597 0.94603161 727.00 -2.17179694e-01 -9.46041155e-02 2.36890182e-01 -2.73077560 0.93304025 727.25 -2.12090230e-01 -9.69201147e-02 2.33186136e-01 -2.71295277 0.92264015 727.50 -2.19083367e-01 -9.21167664e-02 2.37661567e-01 -2.74356992 0.94318056 727.75 -2.32213192e-01 -1.05232590e-01 2.54944827e-01 -2.71610376 0.94019806 728.00 -2.70368191e-01 -1.22364478e-01 2.96769312e-01 -2.71659146 0.93393780 728.25 -2.86937613e-01 -1.15093444e-01 3.09159659e-01 -2.76013005 0.91270170 728.50 -3.12592829e-01 -9.95690596e-02 3.28067484e-01 -2.83322703 0.93513108 728.75 -3.27892837e-01 -6.57800106e-02 3.34425959e-01 -2.94360644 0.89764502 729.00 -3.39767580e-01 -2.12241812e-02 3.40429838e-01 -3.07920695 0.87390761 729.25 -3.22290679e-01 1.09679596e-02 3.22477252e-01 3.10757452 0.91145200 729.50 -3.09775873e-01 3.84906528e-02 3.12158008e-01 3.01797301 0.91997561 729.75 -2.85112526e-01 4.16997702e-02 2.88145837e-01 2.99636510 0.87362178 730.00 -2.69658444e-01 5.52166364e-02 2.75253617e-01 2.93961950 0.84821897 730.25 -2.51600771e-01 4.06108426e-02 2.54857193e-01 2.98156304 0.87123262 730.50 -2.41392933e-01 2.61523210e-02 2.42805461e-01 3.03367435 0.90112527 730.75 -2.41615418e-01 2.30076688e-02 2.42708391e-01 3.04665458 0.94601445 731.00 -2.44664067e-01 3.20835581e-02 2.46758709e-01 3.01120354 0.96534936 731.25 -2.54063206e-01 2.76332363e-02 2.55561555e-01 3.03325332 0.97052090 731.50 -2.55278116e-01 2.99257396e-02 2.57026198e-01 3.02489728 0.96725615 731.75 -2.51671460e-01 3.81192927e-02 2.54541950e-01 2.99127074 0.97529339 732.00 -2.51584008e-01 4.12654085e-02 2.54945772e-01 2.97901789 0.98716249 732.25 -2.57673607e-01 3.71962416e-02 2.60344480e-01 2.99822889 0.99244261 732.50 -2.62375813e-01 3.65474193e-02 2.64909005e-01 3.00318905 0.99282396 732.75 -2.70600287e-01 4.36677639e-02 2.74101056e-01 2.98159829 0.98906686 733.00 -2.77802078e-01 4.41492835e-02 2.81288382e-01 2.98398718 0.99117506 733.25 -2.83825654e-01 4.61261290e-02 2.87549338e-01 2.98048544 0.99229283 733.50 -2.88405300e-01 4.91283454e-02 2.92559757e-01 2.97286739 0.99324756 733.75 -2.96722455e-01 5.87020295e-02 3.02473376e-01 2.94627987 0.99377403 734.00 -3.02977998e-01 6.04961350e-02 3.08958653e-01 2.94451278 0.99408582 734.25 -3.08753223e-01 7.49514560e-02 3.17720433e-01 2.90344415 0.99311534 734.50 -3.07090638e-01 7.91606126e-02 3.17129410e-01 2.88930885 0.99217710 734.75 -3.08291109e-01 9.51016789e-02 3.22626312e-01 2.84237420 0.99219606 735.00 -3.05957505e-01 1.00101283e-01 3.21916545e-01 2.82539587 0.99110358 735.25 -3.00020605e-01 1.01599807e-01 3.16756822e-01 2.81507125 0.99029574 735.50 -2.97112751e-01 1.03701807e-01 3.14690406e-01 2.80578061 0.98838150 735.75 -2.94545341e-01 9.78776310e-02 3.10382004e-01 2.82077173 0.98953039 736.00 -2.94099419e-01 9.47767369e-02 3.08993687e-01 2.82984019 0.98870630 736.25 -2.92650961e-01 9.57427387e-02 3.07914367e-01 2.82541128 0.98519840 736.50 -2.89536405e-01 9.42557660e-02 3.04492166e-01 2.82687216 0.97337853 736.75 -2.87758350e-01 8.15934084e-02 2.99102578e-01 2.86529660 0.97412872 737.00 -2.85132753e-01 8.24494796e-02 2.96814089e-01 2.86010865 0.96550758 737.25 -2.73464081e-01 8.15590612e-02 2.85367279e-01 2.85174751 0.92489321 737.50 -2.85902912e-01 6.74552435e-02 2.93752762e-01 2.90989236 0.89981860 737.75 -2.90079196e-01 4.65682812e-02 2.93793371e-01 2.98241439 0.85498693 738.00 -3.02241063e-01 4.68016099e-02 3.05843180e-01 2.98796419 0.78974703 738.25 -2.76086422e-01 1.84985431e-02 2.76705455e-01 3.07468992 0.74675685 738.50 -2.38683267e-01 1.74321717e-02 2.39318998e-01 3.06868735 0.52145359 738.75 -2.49183203e-01 4.47716652e-02 2.53173400e-01 2.96381580 0.37817345 739.00 -2.05878455e-01 7.33906248e-02 2.18568346e-01 2.79916070 0.30298447 739.25 -2.08044366e-01 1.25669689e-01 2.43054169e-01 2.59819881 0.40566688 739.50 -2.08945733e-01 1.16346928e-01 2.39154609e-01 2.63352200 0.46320769 739.75 -2.23416752e-01 1.19290538e-01 2.53269180e-01 2.65116523 0.48706773 740.00 -2.01104181e-01 1.79447255e-01 2.69525897e-01 2.41304250 0.48476217 740.25 -1.40196984e-01 2.01596746e-01 2.45553339e-01 2.17845046 0.48887819 740.50 -8.51761989e-02 2.00203955e-01 2.17569778e-01 1.97304564 0.36913765 740.75 -5.77921372e-02 2.03396369e-01 2.11447426e-01 1.84763578 0.29941593 741.00 -8.44905587e-02 2.16451208e-01 2.32357010e-01 1.94295147 0.32177217 741.25 -7.92826996e-02 2.51157565e-01 2.63374010e-01 1.87656580 0.37061231 741.50 -4.31951200e-02 3.43426872e-01 3.46132684e-01 1.69591606 0.53872333 741.75 -1.14189678e-02 3.64788821e-01 3.64967501e-01 1.60208906 0.59457914 742.00 -1.71011904e-02 4.09637722e-01 4.09994530e-01 1.61251921 0.60567558 742.25 -4.30621796e-03 4.12879155e-01 4.12901611e-01 1.58122568 0.67180671 742.50 1.16113993e-02 3.80067976e-01 3.80245304e-01 1.54025498 0.57015345 742.75 3.96179500e-02 3.75724256e-01 3.77807224e-01 1.46574032 0.55677909 743.00 4.92210141e-02 3.20996752e-01 3.24748554e-01 1.41864340 0.55010250 743.25 1.15714722e-01 2.79499326e-01 3.02505819e-01 1.17827343 0.55644314 743.50 2.05860603e-01 3.11919968e-01 3.73728048e-01 0.98743800 0.69158703 743.75 2.06426272e-01 3.14301751e-01 3.76028452e-01 0.98967146 0.67746283 744.00 1.78943802e-01 2.66387620e-01 3.20910032e-01 0.97928813 0.64129792 744.25 1.92318241e-01 2.54974108e-01 3.19371416e-01 0.92457071 0.67618794 744.50 2.30499077e-01 2.16831802e-01 3.16458298e-01 0.75485472 0.69207596 744.75 2.47788705e-01 2.10545922e-01 3.25159696e-01 0.70431954 0.68741856 745.00 2.59691091e-01 1.58419656e-01 3.04197715e-01 0.54776272 0.60204724 745.25 2.61734780e-01 7.27145031e-02 2.71647739e-01 0.27098373 0.53907046 745.50 1.95275323e-01 -6.25063635e-02 2.05035356e-01 -0.30978777 0.52549481 745.75 1.78976969e-01 -4.82830945e-02 1.85375329e-01 -0.26349994 0.53150298 746.00 1.65891102e-01 -2.69162373e-02 1.68060529e-01 -0.16085071 0.50359438 746.25 1.33619699e-01 -3.90313488e-02 1.39203700e-01 -0.28420056 0.37471671 746.50 9.28486684e-02 -7.84229663e-02 1.21536155e-01 -0.70136946 0.32405015 746.75 6.72533769e-02 -1.06513309e-01 1.25968654e-01 -1.00760213 0.34559445 747.00 -9.16858253e-03 -1.54432810e-01 1.54704737e-01 -1.63009612 0.39231750 747.25 -6.54291702e-02 -1.58173282e-01 1.71171737e-01 -1.96301856 0.52900499 747.50 -1.31607038e-01 -9.68061327e-02 1.63376375e-01 -2.50739117 0.63567360 747.75 -1.42031898e-01 -6.22844231e-02 1.55088392e-01 -2.72832289 0.75007764 748.00 -1.21848998e-01 -6.37971168e-02 1.37539996e-01 -2.65926323 0.83133235 748.25 -1.15575326e-01 -6.25328405e-02 1.31407808e-01 -2.64564138 0.77793724 748.50 -1.20884961e-01 -6.22101776e-02 1.35953227e-01 -2.66631522 0.78464768 748.75 -1.20091844e-01 -5.77756107e-02 1.33266921e-01 -2.69318293 0.68665052 749.00 -9.60018294e-02 -7.64722424e-02 1.22736935e-01 -2.46894626 0.54438700 749.25 -1.12255718e-01 -1.59070484e-01 1.94691461e-01 -2.18533620 0.59291802 749.50 -1.82204636e-01 -2.18802560e-01 2.84733366e-01 -2.26518162 0.69910150 749.75 -2.45224130e-01 -2.42041088e-01 3.44555891e-01 -2.36272686 0.67416490 750.00 -2.91872592e-01 -2.58519015e-01 3.89899591e-01 -2.41672019 0.81172871 750.25 -3.49234753e-01 -2.68416561e-01 4.40468345e-01 -2.48630292 0.88261499 750.50 -4.18009709e-01 -2.72047996e-01 4.98740643e-01 -2.56464302 0.91956295 750.75 -4.86831219e-01 -2.74514465e-01 5.58894290e-01 -2.62815538 0.86733564 751.00 -5.42203866e-01 -2.72069955e-01 6.06635881e-01 -2.67651779 0.83454081 751.25 -5.95217568e-01 -2.00718864e-01 6.28149676e-01 -2.81634880 0.68430904 751.50 -5.85997860e-01 -1.33324769e-01 6.00973365e-01 -2.91788331 0.51392758 751.75 -6.26633206e-01 5.17138625e-02 6.28763468e-01 3.05925272 0.54821859 752.00 -5.98218950e-01 1.71897325e-01 6.22426383e-01 2.86178276 0.53966427 752.25 -4.73637644e-01 2.64206173e-01 5.42344466e-01 2.63276282 0.38466724 752.50 -3.29473442e-01 3.25605847e-01 4.63219080e-01 2.36209843 0.32245144 752.75 -1.32202530e-01 3.11848901e-01 3.38714107e-01 1.97176148 0.18201704 753.00 -1.14121042e-01 2.31732875e-01 2.58309383e-01 2.02840026 0.13833471 753.25 -2.29759455e-01 2.94138434e-01 3.73238296e-01 2.23392290 0.34077443 753.50 -2.21443780e-01 3.57194574e-01 4.20268143e-01 2.12575797 0.50105663 753.75 -2.07070232e-01 3.87622465e-01 4.39464739e-01 2.06143279 0.66297027 754.00 -2.12520532e-01 4.27439119e-01 4.77356447e-01 2.03219731 0.69570085 754.25 -2.53883935e-01 5.02511608e-01 5.63005300e-01 2.03861917 0.65038372 754.50 -2.87201882e-01 5.12360490e-01 5.87365468e-01 2.08170059 0.63633442 754.75 -2.85970047e-01 4.62285682e-01 5.43587086e-01 2.12478035 0.56885046 755.00 -2.69753019e-01 4.87799420e-01 5.57418124e-01 2.07593979 0.47801392 755.25 -1.79131765e-01 6.21442353e-01 6.46744762e-01 1.85144025 0.40121899 755.50 -1.57616167e-01 5.18304365e-01 5.41740040e-01 1.86601000 0.27693260 755.75 -1.05980089e-01 3.81077963e-01 3.95540382e-01 1.84204791 0.13481269 756.00 -1.70807715e-01 3.85490336e-01 4.21637373e-01 1.98789080 0.14030743 756.25 -1.40402711e-01 3.56809391e-01 3.83439517e-01 1.94568240 0.09832285 756.50 -1.54034437e-01 6.63428343e-02 1.67713981e-01 2.73490287 0.02323055 756.75 -1.03004765e-01 -2.04655286e-02 1.05018187e-01 -2.94546159 0.00801426 757.00 -4.30842662e-02 4.03077172e-02 5.89997123e-02 2.38947735 0.00255132 757.25 1.84135589e-01 -6.56496462e-02 1.95488596e-01 -0.34247927 0.03220238 757.50 1.71553719e-01 -1.03974923e-01 2.00602749e-01 -0.54487659 0.04192542 757.75 1.63235977e-01 -2.00330182e-01 2.58414717e-01 -0.88707508 0.07234704 758.00 1.47226251e-01 -7.62637257e-02 1.65806287e-01 -0.47794652 0.02836005 758.25 4.06632337e-02 -2.01231201e-01 2.05298551e-01 -1.37140905 0.05401334 758.50 1.07828202e-01 -3.48931508e-01 3.65212429e-01 -1.27108135 0.19538209 758.75 2.15510401e-01 -3.27990722e-01 3.92457191e-01 -0.98947227 0.28774923 759.00 1.20728147e-01 -3.42809578e-01 3.63446960e-01 -1.23218730 0.27390645 759.25 5.49435233e-02 -3.50345866e-01 3.54627998e-01 -1.41523685 0.30459201 759.50 1.25854970e-01 -2.44892544e-01 2.75339484e-01 -1.09607550 0.31503017 759.75 1.17039215e-01 -3.05500635e-01 3.27152588e-01 -1.20493778 0.48204553 760.00 9.04534068e-02 -2.87203454e-01 3.01110682e-01 -1.26568517 0.45782744 760.25 9.36121304e-02 -2.49389296e-01 2.66379901e-01 -1.21170528 0.33940024 760.50 9.48074900e-02 -2.00252907e-01 2.21561925e-01 -1.12862258 0.24168134 760.75 7.97166571e-02 -2.36163320e-01 2.49254608e-01 -1.24525662 0.34415967 761.00 3.18610061e-02 -1.79339618e-01 1.82147804e-01 -1.39497342 0.30202702 761.25 1.29678896e-01 -1.34912292e-01 1.87130817e-01 -0.80517476 0.34742525 761.50 2.09773563e-01 -1.16342478e-01 2.39876051e-01 -0.50637553 0.50165132 761.75 2.58384361e-01 -1.05683830e-01 2.79162229e-01 -0.38825618 0.69317016 762.00 2.87502071e-01 -7.28528613e-02 2.96588908e-01 -0.24817556 0.64409927 762.25 3.11360759e-01 -7.41284684e-02 3.20063356e-01 -0.23372785 0.59835690 762.50 3.84199974e-01 -1.70470326e-01 4.20321011e-01 -0.41760424 0.71056578 762.75 3.86305398e-01 -1.95736504e-01 4.33064244e-01 -0.46898408 0.73226599 763.00 3.71811473e-01 -2.53535285e-01 4.50026568e-01 -0.59846931 0.68121767 763.25 4.05924414e-01 -2.78814890e-01 4.92455453e-01 -0.60185538 0.69761060 763.50 4.17830781e-01 -3.65397370e-01 5.55065581e-01 -0.71855265 0.78467750 763.75 4.36237242e-01 -4.20406992e-01 6.05842364e-01 -0.76692089 0.86446744 764.00 4.42212227e-01 -4.70861666e-01 6.45958483e-01 -0.81676478 0.88976105 764.25 4.47880628e-01 -5.12294648e-01 6.80472530e-01 -0.85238348 0.89130652 764.50 4.40489973e-01 -5.63046078e-01 7.14879222e-01 -0.90692067 0.93380916 764.75 4.47653542e-01 -5.52899665e-01 7.11401246e-01 -0.89020070 0.93426605 765.00 4.29780244e-01 -6.09298870e-01 7.45624685e-01 -0.95647641 0.94578391 765.25 4.49368621e-01 -6.09351372e-01 7.57126972e-01 -0.93537311 0.95486207 765.50 4.73699965e-01 -6.46844901e-01 8.01748079e-01 -0.93870425 0.96630846 765.75 4.98283565e-01 -6.46372747e-01 8.16139840e-01 -0.91405788 0.95883863 766.00 4.91790435e-01 -6.42581411e-01 8.09177794e-01 -0.91755246 0.96069298 766.25 4.81235744e-01 -6.59037122e-01 8.16037848e-01 -0.94008134 0.95183350 766.50 5.39598252e-01 -7.40507912e-01 9.16252281e-01 -0.94107586 0.93787382 766.75 5.34154493e-01 -7.60886234e-01 9.29660628e-01 -0.95871846 0.93978221 767.00 5.40174923e-01 -8.42231955e-01 1.00057164e+00 -1.00051805 0.92472024 767.25 4.64523865e-01 -9.09269401e-01 1.02105498e+00 -1.09848587 0.93063461 767.50 3.30114058e-01 -9.60871595e-01 1.01599681e+00 -1.23987296 0.95228484 767.75 2.71018721e-01 -9.35517976e-01 9.73984102e-01 -1.28881648 0.94236137 768.00 1.66960388e-01 -8.65343571e-01 8.81303164e-01 -1.38019724 0.93430307 768.25 1.24274184e-01 -8.15095716e-01 8.24515069e-01 -1.41949576 0.92621308 768.50 1.04841137e-01 -7.52176277e-01 7.59447704e-01 -1.43230486 0.93203641 768.75 1.22764174e-01 -7.00676615e-01 7.11349957e-01 -1.39734881 0.94647686 769.00 1.36205914e-01 -6.42886107e-01 6.57156448e-01 -1.36201731 0.94316655 769.25 1.64650146e-01 -5.95424582e-01 6.17770267e-01 -1.30101232 0.92835040 769.50 1.97228743e-01 -5.83635709e-01 6.16059914e-01 -1.24491337 0.92971399 769.75 2.11998957e-01 -5.81359019e-01 6.18806808e-01 -1.22112066 0.91431048 770.00 2.23808224e-01 -5.78254277e-01 6.20054941e-01 -1.20151101 0.91306253 770.25 2.32930483e-01 -5.55315784e-01 6.02189530e-01 -1.17363094 0.90082211 770.50 2.44575709e-01 -5.47193136e-01 5.99364335e-01 -1.15046989 0.90159634 770.75 2.78858397e-01 -5.49075614e-01 6.15829550e-01 -1.10087348 0.85813340 771.00 2.97501208e-01 -5.45433099e-01 6.21292390e-01 -1.07146056 0.84727722 771.25 3.44596199e-01 -5.41101084e-01 6.41511437e-01 -1.00372630 0.82926210 771.50 4.19434203e-01 -5.43852664e-01 6.86804754e-01 -0.91384738 0.83757495 771.75 4.78973680e-01 -5.22292788e-01 7.08664619e-01 -0.82863551 0.81176510 772.00 5.40790228e-01 -5.48135789e-01 7.70004490e-01 -0.79214375 0.76777497 772.25 4.65917187e-01 -6.10330843e-01 7.67842798e-01 -0.91878394 0.62696779 772.50 4.75656345e-01 -8.07266195e-01 9.36977944e-01 -1.03834196 0.66351729 772.75 3.02601163e-01 -9.63877631e-01 1.01026113e+00 -1.26659877 0.63379894 773.00 1.58504089e-01 -1.07215725e+00 1.08381027e+00 -1.42402284 0.66592272 773.25 -2.47572395e-01 -9.86817318e-01 1.01739889e+00 -1.81660274 0.69132415 773.50 -3.93525594e-01 -8.97002918e-01 9.79528778e-01 -1.98422327 0.72466499 773.75 -3.56558974e-01 -8.11857181e-01 8.86705353e-01 -1.98462378 0.76228535 774.00 -3.41896754e-01 -7.46178674e-01 8.20777683e-01 -2.00044585 0.75857324 774.25 -2.92860534e-01 -7.07710527e-01 7.65912189e-01 -1.96315432 0.75133930 774.50 -3.73524372e-01 -6.92140452e-01 7.86497846e-01 -2.06567063 0.75705535 774.75 -5.51112839e-01 -5.57349054e-01 7.83813325e-01 -2.35056854 0.78514510 775.00 -5.64689035e-01 -4.65025476e-01 7.31520608e-01 -2.45268151 0.76086989 775.25 -6.29613084e-01 -2.65101735e-01 6.83148275e-01 -2.74306820 0.61251801 775.50 -6.54332099e-01 -1.15860419e-01 6.64510446e-01 -2.96634241 0.62791711 775.75 -4.96269542e-01 -4.77665546e-02 4.98563037e-01 -3.04563701 0.58812826 776.00 -3.69564538e-01 -3.09643702e-02 3.70859461e-01 -3.05800180 0.46842129 776.25 -2.06458279e-01 2.22032724e-02 2.07648757e-01 3.03446078 0.38210242 776.50 -1.96017177e-01 3.81327368e-02 1.99691860e-01 2.94945475 0.38336258 776.75 -1.28809515e-01 4.36357244e-02 1.35999881e-01 2.81496459 0.17333544 777.00 -9.08095778e-02 1.77641621e-02 9.25307780e-02 2.94841224 0.10099756 777.25 -1.43842190e-01 -5.70896766e-02 1.54757251e-01 -2.76376928 0.38523341 777.50 -1.60888164e-01 -6.19627892e-02 1.72407623e-01 -2.77397097 0.54076028 777.75 -1.66492894e-01 -5.57637221e-02 1.75583247e-01 -2.81840440 0.69614751 778.00 -1.84225799e-01 -4.59317681e-02 1.89865406e-01 -2.89725107 0.71149351 778.25 -1.92226449e-01 -2.90621831e-03 1.92248417e-01 -3.12647508 0.71161609 778.50 -1.97350032e-01 9.78695970e-03 1.97592560e-01 3.09204137 0.58465938 778.75 -1.94121912e-01 2.91623082e-02 1.96300170e-01 2.99248093 0.41892734 779.00 -1.97165075e-01 4.75492179e-02 2.02817640e-01 2.90494688 0.38153726 779.25 -2.11835110e-01 1.17256483e-01 2.42122276e-01 2.63604550 0.40547077 779.50 -1.87181322e-01 1.54057037e-01 2.42426108e-01 2.45296213 0.35781490 779.75 -2.15138907e-01 2.69450772e-01 3.44802071e-01 2.24458223 0.41943863 780.00 -1.51448203e-01 4.23729205e-01 4.49981108e-01 1.91406376 0.48466556 780.25 1.50333852e-01 5.42124213e-01 5.62582375e-01 1.30028828 0.62756386 780.50 2.56914944e-01 5.30954518e-01 5.89845733e-01 1.12013276 0.75284985 780.75 3.28151598e-01 4.89685751e-01 5.89470615e-01 0.98040200 0.79628289 781.00 3.79632068e-01 3.41266627e-01 5.10473719e-01 0.73222941 0.73485884 781.25 4.72700605e-01 2.58345082e-01 5.38691047e-01 0.50017523 0.80113576 781.50 4.93289386e-01 1.94181357e-01 5.30132830e-01 0.37501675 0.83275700 781.75 5.18042377e-01 1.23520712e-01 5.32564804e-01 0.23406702 0.90256594 782.00 4.56301819e-01 6.52250328e-02 4.60939969e-01 0.14198094 0.87456881 782.25 4.36294377e-01 1.24685354e-02 4.36472506e-01 0.02857049 0.88454646 782.50 4.09677390e-01 -4.94887969e-02 4.12655674e-01 -0.12021694 0.86456658 782.75 3.47628783e-01 -8.13545546e-02 3.57021476e-01 -0.22988977 0.85471732 783.00 2.91016083e-01 -7.40177268e-02 3.00281509e-01 -0.24906143 0.86154713 783.25 2.48479031e-01 -7.95708339e-02 2.60908694e-01 -0.30991300 0.87135941 783.50 1.71516106e-01 -4.86515043e-02 1.78282763e-01 -0.27639531 0.75159187 783.75 1.49085488e-01 -3.14180021e-02 1.52360013e-01 -0.20769908 0.75550239 784.00 1.30571070e-01 1.01829168e-02 1.30967539e-01 0.07783001 0.67200454 784.25 1.23540757e-01 3.67020456e-02 1.28877301e-01 0.28877989 0.71199387 784.50 1.25072422e-01 1.03266879e-01 1.62194819e-01 0.69019065 0.77315899 784.75 1.34438016e-01 1.27913224e-01 1.85567704e-01 0.76053285 0.86301829 785.00 1.56097482e-01 1.39668488e-01 2.09460522e-01 0.72990791 0.87593545 785.25 1.74736534e-01 1.54913998e-01 2.33519171e-01 0.72533851 0.91202250 785.50 2.05824434e-01 1.86580847e-01 2.77805886e-01 0.73639734 0.95587109 785.75 2.26680592e-01 1.91586082e-01 2.96798446e-01 0.70168960 0.96053953 786.00 2.84726933e-01 1.74402324e-01 3.33894590e-01 0.54957809 0.96061135 786.25 3.14612946e-01 1.68622227e-01 3.56952043e-01 0.49200569 0.97426583 786.50 3.42275999e-01 1.50970792e-01 3.74092287e-01 0.41541059 0.97541790 786.75 3.45849132e-01 1.41635277e-01 3.73727406e-01 0.38869401 0.96148924 787.00 3.69825272e-01 1.08115847e-01 3.85304773e-01 0.28441735 0.92498072 787.25 3.87515791e-01 9.36266444e-02 3.98665821e-01 0.23706419 0.92583669 787.50 4.28488636e-01 4.43364963e-02 4.30776318e-01 0.10310490 0.93827999 787.75 4.29405332e-01 3.39782312e-02 4.30747559e-01 0.07896404 0.93522622 788.00 4.36240278e-01 2.47092873e-02 4.36939503e-01 0.05658101 0.90845962 788.25 4.52029402e-01 -8.10952802e-03 4.52102140e-01 -0.01793834 0.87937636 788.50 4.20123246e-01 -7.84316871e-02 4.27381646e-01 -0.18456276 0.86355895 788.75 3.93210111e-01 -1.27729673e-01 4.13435679e-01 -0.31408557 0.86770153 789.00 3.24999910e-01 -1.90105806e-01 3.76517143e-01 -0.52927319 0.84241791 789.25 2.73118386e-01 -1.86403045e-01 3.30665613e-01 -0.59888356 0.82015386 789.50 2.23023877e-01 -1.79973472e-01 2.86583497e-01 -0.67897623 0.85414254 789.75 1.76383103e-01 -1.58101159e-01 2.36869111e-01 -0.73079538 0.78394086 790.00 1.23421884e-01 -1.34253434e-01 1.82364871e-01 -0.82740908 0.71032690 790.25 1.24309113e-01 -8.65224417e-02 1.51455896e-01 -0.60805423 0.64980540 790.50 1.14655288e-01 -5.41157610e-02 1.26784662e-01 -0.44098681 0.57244418 790.75 1.00742376e-01 -3.72385351e-02 1.07404538e-01 -0.35406431 0.53079523 791.00 1.03437663e-01 -2.91134882e-02 1.07456714e-01 -0.27436136 0.58038443 791.25 1.05205968e-01 -3.46658563e-02 1.10770110e-01 -0.31830080 0.55955373 791.50 9.54723622e-02 -8.66757751e-04 9.54762966e-02 -0.00907838 0.46316125 791.75 7.92459665e-02 1.42869172e-02 8.05235320e-02 0.17836969 0.37941212 792.00 7.84303551e-02 4.80196902e-02 9.19630972e-02 0.54938474 0.38295467 792.25 8.07304581e-02 7.33544267e-02 1.09079232e-01 0.73756476 0.48731577 792.50 8.83984638e-02 6.80260969e-02 1.11542988e-01 0.65588947 0.59125783 792.75 8.51618351e-02 7.46277192e-02 1.13233540e-01 0.71956849 0.51494912 793.00 8.34628245e-02 5.74786954e-02 1.01340236e-01 0.60308426 0.42494654 793.25 8.07625444e-02 8.95353918e-02 1.20578501e-01 0.83686737 0.36549492 793.50 8.75504116e-02 1.07632557e-01 1.38743800e-01 0.88792621 0.41638815 793.75 9.76003207e-02 6.89275378e-02 1.19485681e-01 0.61488991 0.40241841 794.00 7.43283912e-02 8.65948514e-02 1.14120016e-01 0.86147658 0.37554289 794.25 8.00859920e-02 1.40824450e-01 1.62003987e-01 1.05371424 0.60377931 794.50 1.00223329e-01 1.53947329e-01 1.83696750e-01 0.99370194 0.66676330 794.75 1.15414412e-01 2.08984350e-01 2.38736142e-01 1.06621703 0.69219721 795.00 1.43706639e-01 2.23035271e-01 2.65323067e-01 0.99842269 0.75076146 795.25 1.43385093e-01 2.16543167e-01 2.59711817e-01 0.98592385 0.75291399 795.50 1.43955365e-01 2.21691140e-01 2.64329545e-01 0.99487747 0.70003476 795.75 1.36433950e-01 1.97555717e-01 2.40088492e-01 0.96640023 0.69987693 796.00 1.31826922e-01 1.86763977e-01 2.28602538e-01 0.95615651 0.74037960 796.25 1.91956492e-01 1.73743104e-01 2.58909175e-01 0.73563505 0.77198134 796.50 1.91194031e-01 1.72272367e-01 2.57357584e-01 0.73338621 0.79064211 796.75 2.06714774e-01 1.57189959e-01 2.59691511e-01 0.65013635 0.77917829 797.00 2.04254809e-01 1.52550274e-01 2.54934527e-01 0.64149014 0.78500548 797.25 1.78019319e-01 1.45339385e-01 2.29813870e-01 0.68467613 0.82175502 797.50 1.67497422e-01 1.51614497e-01 2.25925524e-01 0.73566693 0.84142746 797.75 1.37520286e-01 1.90301086e-01 2.34789975e-01 0.94503295 0.86564979 798.00 1.38833569e-01 1.99432386e-01 2.42998018e-01 0.96266328 0.86224916 798.25 1.69132457e-01 1.85229776e-01 2.50830337e-01 0.83079313 0.83828773 798.50 1.81013049e-01 1.79726590e-01 2.55083066e-01 0.78183201 0.85267356 798.75 1.81215582e-01 1.72920678e-01 2.50480833e-01 0.76197953 0.84955921 799.00 1.85412597e-01 1.70068876e-01 2.51597404e-01 0.74226173 0.83358925 799.25 1.62670526e-01 1.60186664e-01 2.28301264e-01 0.77770494 0.80500044 799.50 1.62284458e-01 1.59493917e-01 2.27540227e-01 0.77672614 0.81374195 799.75 1.59755334e-01 1.49257603e-01 2.18631193e-01 0.75143941 0.78970671 800.00 1.61122265e-01 1.46190399e-01 2.17559226e-01 0.73684783 0.72826982 800.25 1.42156875e-01 1.39561770e-01 1.99213616e-01 0.77618673 0.60005089 800.50 1.63302856e-01 1.48237740e-01 2.20549881e-01 0.73707897 0.53818345 800.75 2.06158567e-01 1.62676048e-01 2.62611598e-01 0.66804818 0.61432085 801.00 2.27826737e-01 1.96032525e-01 3.00555774e-01 0.71052713 0.71856205 801.25 2.50241671e-01 2.03649834e-01 3.22636248e-01 0.68310672 0.78283523 801.50 2.63118800e-01 2.03022579e-01 3.32339691e-01 0.65718267 0.87158817 801.75 2.68538727e-01 2.15339607e-01 3.44215331e-01 0.67589478 0.90064439 802.00 2.64098001e-01 2.27230448e-01 3.48398379e-01 0.71050205 0.93390216 802.25 2.72181113e-01 2.27363387e-01 3.54650064e-01 0.69592054 0.95423906 802.50 2.74927650e-01 2.33390476e-01 3.60633231e-01 0.70386440 0.97341241 802.75 2.70012618e-01 2.38758277e-01 3.60433529e-01 0.72404419 0.97604048 803.00 2.70508727e-01 2.15763475e-01 3.46018566e-01 0.67328872 0.97051726 803.25 2.75130781e-01 2.07510325e-01 3.44612074e-01 0.64619919 0.98036353 803.50 2.68171584e-01 2.19487875e-01 3.46541377e-01 0.68589648 0.98300782 803.75 2.68146736e-01 2.20958658e-01 3.47455609e-01 0.68921750 0.98328425 804.00 2.72270995e-01 2.09415876e-01 3.43491636e-01 0.65564174 0.98286471 804.25 2.79005155e-01 2.05738294e-01 3.46658509e-01 0.63538797 0.98531348 804.50 2.80240733e-01 1.96912337e-01 3.42504506e-01 0.61250511 0.99047605 804.75 2.82333113e-01 1.91927597e-01 3.41391548e-01 0.59703394 0.99474151 805.00 2.83938589e-01 1.82775052e-01 3.37680088e-01 0.57194306 0.99592775 805.25 2.84243834e-01 1.78269925e-01 3.35521569e-01 0.56016006 0.99648555 805.50 2.73941399e-01 1.65869838e-01 3.20244739e-01 0.54444932 0.99504090 805.75 2.67523399e-01 1.59009072e-01 3.11211591e-01 0.53627280 0.99633912 806.00 2.52957232e-01 1.52156560e-01 2.95193123e-01 0.54152980 0.99542358 806.25 2.46329889e-01 1.48800781e-01 2.87784792e-01 0.54340762 0.99703997 806.50 2.37158178e-01 1.47704918e-01 2.79393529e-01 0.55702425 0.99620977 806.75 2.29087996e-01 1.48823366e-01 2.73184377e-01 0.57611793 0.99624196 807.00 2.17210710e-01 1.48965565e-01 2.63384191e-01 0.60113976 0.99521827 807.25 2.10308104e-01 1.47940182e-01 2.57129921e-01 0.61303430 0.99467644 807.50 1.92691465e-01 1.42891115e-01 2.39891374e-01 0.63807368 0.99328240 807.75 1.83481162e-01 1.44156234e-01 2.33337431e-01 0.66594384 0.99014468 808.00 1.54771152e-01 1.51475434e-01 2.16561576e-01 0.77463693 0.98802028 808.25 1.44343504e-01 1.61366024e-01 2.16504135e-01 0.84102273 0.98722323 808.50 1.27910278e-01 1.79332812e-01 2.20275502e-01 0.95122874 0.98888417 808.75 1.19722702e-01 1.88719765e-01 2.23492003e-01 1.00547022 0.98916444 809.00 1.08627157e-01 2.05739716e-01 2.32655733e-01 1.08501341 0.98989506 809.25 1.06449966e-01 2.15573391e-01 2.40423547e-01 1.11212166 0.98958752 809.50 1.06231061e-01 2.35669296e-01 2.58505426e-01 1.14730785 0.99157292 809.75 1.02686580e-01 2.42459310e-01 2.63307901e-01 1.17017918 0.99013573 810.00 9.66352124e-02 2.50571070e-01 2.68559538e-01 1.20271290 0.98698822 810.25 9.02046979e-02 2.53606167e-01 2.69170904e-01 1.22906316 0.98514841 810.50 7.56407610e-02 2.62099102e-01 2.72795645e-01 1.28983444 0.98376995 810.75 6.29217811e-02 2.77951857e-01 2.84984886e-01 1.34817206 0.97118848 811.00 4.33020627e-02 3.00897941e-01 3.03997762e-01 1.42786815 0.97468595 811.25 2.50554788e-02 3.27819237e-01 3.28775348e-01 1.49451386 0.96394971 811.50 1.47639248e-02 3.73085594e-01 3.73377602e-01 1.53124448 0.97909653 811.75 1.87317269e-02 3.84650214e-01 3.85106044e-01 1.52213669 0.96727205 812.00 1.22556631e-02 4.19474217e-01 4.19653214e-01 1.54158791 0.94899226 812.25 6.65120524e-03 4.41352166e-01 4.41402280e-01 1.55572740 0.91314183 812.50 -7.60106417e-03 4.88437184e-01 4.88496324e-01 1.58635708 0.92159865 812.75 -2.69518475e-02 5.38012602e-01 5.38687258e-01 1.62084968 0.87496406 813.00 -5.80562578e-02 5.80982856e-01 5.83876364e-01 1.67039336 0.81929453 813.25 -2.66015194e-02 7.13915297e-01 7.14410731e-01 1.60804055 0.69061919 813.50 1.58297099e-01 1.00022720e+00 1.01267587e+00 1.41383698 0.68932894 813.75 6.92084607e-01 5.68185015e-01 8.95441408e-01 0.68740110 0.59562329 814.00 7.97837161e-01 2.43414766e-01 8.34143203e-01 0.29612296 0.82732550 814.25 6.23574000e-01 1.85234496e-01 6.50504690e-01 0.28875089 0.92402096 814.50 5.15232769e-01 2.05006430e-01 5.54520011e-01 0.37868687 0.92908744 814.75 3.80339248e-01 2.74235824e-01 4.68895757e-01 0.62470075 0.93229393 815.00 3.46929286e-01 3.14040002e-01 4.67954114e-01 0.73568000 0.96627408 815.25 3.26470150e-01 3.42019157e-01 4.72821174e-01 0.80865389 0.97123359 815.50 3.15485178e-01 3.52272242e-01 4.72891774e-01 0.84043299 0.97383237 815.75 3.13790920e-01 3.95062624e-01 5.04518799e-01 0.89955204 0.96570775 816.00 3.21783966e-01 4.25268183e-01 5.33289741e-01 0.92304561 0.97310019 816.25 3.24231515e-01 4.48767839e-01 5.53641264e-01 0.94513351 0.97227843 816.50 3.40205225e-01 4.66388366e-01 5.77284768e-01 0.94057994 0.97872400 816.75 3.73743442e-01 4.42542123e-01 5.79247521e-01 0.86948205 0.97878606 817.00 3.81985476e-01 4.36030073e-01 5.79685370e-01 0.85137022 0.97286927 817.25 3.67130611e-01 4.34121702e-01 5.68547744e-01 0.86881215 0.96885992 817.50 3.55195131e-01 4.25116404e-01 5.53974312e-01 0.87476635 0.96582525 817.75 3.19737528e-01 4.11800190e-01 5.21355429e-01 0.91058816 0.96975173 818.00 3.04617149e-01 4.16720549e-01 5.16185648e-01 0.93957524 0.96460515 818.25 2.53594190e-01 4.41877146e-01 5.09475637e-01 1.04978759 0.96220850 818.50 2.28430923e-01 4.54960994e-01 5.09087608e-01 1.10547889 0.95474087 818.75 1.70572112e-01 4.80479895e-01 5.09858583e-01 1.22967090 0.95049445 819.00 1.38420721e-01 4.98996948e-01 5.17839986e-01 1.30020215 0.94269230 819.25 4.15658149e-02 5.17834236e-01 5.19499771e-01 1.49069948 0.92083494 819.50 5.48815235e-03 5.21632683e-01 5.21661553e-01 1.56027561 0.88564216 819.75 -1.02237235e-01 5.43403376e-01 5.52937321e-01 1.75676482 0.76656992 820.00 -1.66180875e-01 4.98535731e-01 5.25503529e-01 1.89255103 0.61873873 820.25 -3.07383223e-01 1.90168988e-01 3.61453579e-01 2.58755771 0.24313858 820.50 -5.31572239e-02 4.76807797e-02 7.14083133e-02 2.41045052 0.00742337 820.75 3.93150147e-01 -2.48524221e-01 4.65114315e-01 -0.56371412 0.20086686 821.00 4.82865863e-01 -9.43371785e-02 4.91994863e-01 -0.19293905 0.22687311 821.25 7.77302749e-01 2.21142900e-01 8.08148344e-01 0.27717698 0.36759648 821.50 8.94174649e-01 1.22788647e-01 9.02565983e-01 0.13646714 0.40953170 821.75 1.17447055e+00 6.13753463e-02 1.17607313e+00 0.05221039 0.44692247 822.00 1.02337928e+00 -1.29300874e-01 1.03151533e+00 -0.12568102 0.35603400 822.25 1.09448216e+00 -5.45230197e-01 1.22277028e+00 -0.46217670 0.41380025 822.50 8.31052147e-01 -6.99072212e-01 1.08597865e+00 -0.69935673 0.53159434 822.75 6.52138544e-01 -7.73173342e-01 1.01147501e+00 -0.87011304 0.69593216 823.00 7.42520112e-01 -6.05111597e-01 9.57860199e-01 -0.68378637 0.82486302 823.25 7.34542708e-01 -5.55810337e-01 9.21128721e-01 -0.64775964 0.90140659 823.50 7.20284652e-01 -4.98102778e-01 8.75737608e-01 -0.60502282 0.93617154 823.75 6.97375544e-01 -4.53798247e-01 8.32024938e-01 -0.57688325 0.95792792 824.00 6.87826536e-01 -3.63027758e-01 7.77749636e-01 -0.48563141 0.96037064 824.25 6.92580131e-01 -3.29890043e-01 7.67134068e-01 -0.44452511 0.97668083 824.50 7.09980409e-01 -2.79903355e-01 7.63163200e-01 -0.37553185 0.98239194 824.75 7.15812211e-01 -2.56066839e-01 7.60235060e-01 -0.34354375 0.98961080 825.00 7.39738036e-01 -2.21187510e-01 7.72098619e-01 -0.29054635 0.98577235 825.25 7.64452524e-01 -1.99674881e-01 7.90099816e-01 -0.25549160 0.98976677 825.50 8.17940461e-01 -1.92985629e-01 8.40398745e-01 -0.23170346 0.98717075 825.75 8.62669182e-01 -1.94892164e-01 8.84410014e-01 -0.22218767 0.98403873 826.00 9.78213269e-01 -2.25996960e-01 1.00397999e+00 -0.22704676 0.96954880 826.25 1.05308211e+00 -2.83764509e-01 1.09064395e+00 -0.26320935 0.96601776 826.50 1.02065350e+00 -5.20427729e-01 1.14567822e+00 -0.47153349 0.89355184 826.75 8.12231704e-01 -6.67623327e-01 1.05139966e+00 -0.68798949 0.86560621 827.00 5.47829114e-01 -6.52094001e-01 8.51670902e-01 -0.87207343 0.92796927 827.25 5.08098772e-01 -6.12661867e-01 7.95939021e-01 -0.87842542 0.95679526 827.50 4.93281701e-01 -5.19818123e-01 7.16615460e-01 -0.81158547 0.98205651 827.75 4.91616707e-01 -4.90026640e-01 6.94127578e-01 -0.78377836 0.98807319 828.00 4.84136364e-01 -4.50668725e-01 6.61430510e-01 -0.74961172 0.99379050 828.25 4.77757445e-01 -4.35602392e-01 6.46530447e-01 -0.73927707 0.99330426 828.50 4.82134035e-01 -4.16937252e-01 6.37408738e-01 -0.71300917 0.98928436 828.75 4.81998557e-01 -3.91405047e-01 6.20902987e-01 -0.68204308 0.98989071 829.00 4.73120614e-01 -3.63838451e-01 5.96842972e-01 -0.65556218 0.99336868 829.25 4.75432895e-01 -3.58246629e-01 5.95295796e-01 -0.64574800 0.99328372 829.50 4.85277132e-01 -3.41052755e-01 5.93136474e-01 -0.61260267 0.99089826 829.75 4.92323477e-01 -3.26504252e-01 5.90751583e-01 -0.58559216 0.98937718 830.00 5.08770081e-01 -3.21152117e-01 6.01652455e-01 -0.56306843 0.99243427 830.25 5.10920410e-01 -3.18278550e-01 6.01947590e-01 -0.55712476 0.99187369 830.50 5.10802852e-01 -3.11113519e-01 5.98089604e-01 -0.54706026 0.99335811 830.75 5.23061901e-01 -3.08256489e-01 6.07137395e-01 -0.53253756 0.99240840 831.00 5.42076059e-01 -3.07309445e-01 6.23125628e-01 -0.51573472 0.99107851 831.25 5.62175114e-01 -2.96851871e-01 6.35737282e-01 -0.48582845 0.98752140 831.50 5.95959105e-01 -2.71022290e-01 6.54691024e-01 -0.42681075 0.98758907 831.75 6.12433707e-01 -2.61943602e-01 6.66100215e-01 -0.40416322 0.98462080 832.00 6.62270010e-01 -2.70066280e-01 7.15218401e-01 -0.38720276 0.98872803 832.25 6.96989838e-01 -2.68946507e-01 7.47079017e-01 -0.36826511 0.98017461 832.50 7.63724156e-01 -2.43378203e-01 8.01565678e-01 -0.30849867 0.97401916 832.75 8.40766892e-01 -2.45516494e-01 8.75880880e-01 -0.28411505 0.96338437 833.00 9.43564041e-01 -2.37078236e-01 9.72892177e-01 -0.24616253 0.97319522 833.25 1.02016056e+00 -2.28312531e-01 1.04539666e+00 -0.22017253 0.94689821 833.50 1.22601159e+00 -1.91763707e-01 1.24091811e+00 -0.15515550 0.91969578 833.75 1.39509339e+00 -1.66706473e-02 1.39519299e+00 -0.01194892 0.75311810 834.00 1.66908360e+00 2.91381936e-01 1.69432685e+00 0.17283423 0.76246493 834.25 1.51300162e+00 7.44811483e-01 1.68639203e+00 0.45744779 0.52133950 834.50 8.32883026e-01 1.35043325e+00 1.58662034e+00 1.01814982 0.29349194 834.75 -5.04178951e-01 1.00234092e+00 1.12199988e+00 2.03684222 0.23682929 835.00 -9.62238239e-01 8.78746848e-01 1.30311107e+00 2.40151491 0.48061778 835.25 -8.45700112e-01 5.42767725e-01 1.00489078e+00 2.57100573 0.52425823 835.50 -8.84864483e-01 5.06246237e-01 1.01944613e+00 2.62192753 0.71758545 835.75 -7.09711128e-01 2.60095399e-01 7.55870030e-01 2.79031184 0.72561643 836.00 -6.28790515e-01 1.83458265e-01 6.55007211e-01 2.85770909 0.80540063 836.25 -5.76685190e-01 7.47354377e-02 5.81507691e-01 3.01271607 0.83912768 836.50 -5.70457843e-01 4.79565206e-02 5.72470068e-01 3.05772314 0.86823453 836.75 -5.42943489e-01 -4.04139158e-03 5.42958530e-01 -3.13414931 0.82113793 837.00 -5.59184588e-01 1.00232063e-02 5.59274412e-01 3.12366989 0.83292908 837.25 -5.90117768e-01 1.04751465e-01 5.99342848e-01 2.96591317 0.79443699 837.50 -6.04992750e-01 1.81013784e-01 6.31492057e-01 2.85087004 0.80913677 837.75 -5.88639830e-01 2.92674377e-01 6.57385077e-01 2.68018394 0.85639427 838.00 -4.68662325e-01 2.99898238e-01 5.56402128e-01 2.57234857 0.83534547 838.25 -2.91234136e-01 3.68220574e-01 4.69471739e-01 2.23997798 0.79285555 838.50 -2.25209078e-01 3.92911650e-01 4.52878233e-01 2.09126171 0.80208579 838.75 -1.47009238e-01 3.86595146e-01 4.13603099e-01 1.93417631 0.79200881 839.00 -7.50550070e-02 3.72731722e-01 3.80213349e-01 1.76950374 0.78426496 839.25 -2.43587124e-02 2.73247084e-01 2.74330669e-01 1.65970667 0.73071005 839.50 -1.70461292e-02 2.48929597e-01 2.49512555e-01 1.63916730 0.66306268 839.75 -2.86563574e-02 2.26014555e-01 2.27823980e-01 1.69691327 0.64746861 840.00 -3.17052828e-02 2.16150153e-01 2.18463072e-01 1.71643947 0.60706244 840.25 -1.98736129e-02 1.62901589e-01 1.64109379e-01 1.69219409 0.60416012 840.50 -1.19836628e-02 1.69712839e-01 1.70135404e-01 1.64129073 0.66820970 840.75 4.91226472e-04 1.77644014e-01 1.77644693e-01 1.56803110 0.65417191 841.00 9.42479237e-03 1.97611830e-01 1.97836453e-01 1.52313898 0.72949350 841.25 2.00103518e-02 2.32174463e-01 2.33035180e-01 1.48482208 0.86136755 841.50 3.92940143e-02 2.19625034e-01 2.23112472e-01 1.39375541 0.81675433 841.75 5.91024991e-02 1.88504180e-01 1.97552350e-01 1.26696959 0.80536417 842.00 6.49666629e-02 1.79266299e-01 1.90675308e-01 1.22311498 0.79408536 842.25 8.66258088e-02 1.75846703e-01 1.96025748e-01 1.11306919 0.85990734 842.50 9.15749983e-02 1.69189475e-01 1.92382584e-01 1.07469031 0.85819407 842.75 7.84654659e-02 1.64074728e-01 1.81871784e-01 1.12471586 0.85895400 843.00 6.79325926e-02 1.46363643e-01 1.61360321e-01 1.13624953 0.79842732 843.25 5.65514298e-02 1.48274412e-01 1.58692676e-01 1.20642907 0.80340142 843.50 4.71418506e-02 1.60818160e-01 1.67585305e-01 1.28564713 0.75985972 843.75 4.19036848e-02 1.76016752e-01 1.80935944e-01 1.33708038 0.82115907 844.00 5.21322083e-02 1.74979279e-01 1.82580161e-01 1.28123638 0.78550150 844.25 5.55853106e-02 1.80201239e-01 1.88579462e-01 1.27159404 0.77751959 844.50 4.56041474e-02 1.90648278e-01 1.96026794e-01 1.33600256 0.75576955 844.75 5.23530845e-02 2.16410916e-01 2.22653386e-01 1.33344127 0.79225944 845.00 6.91565592e-02 2.41947471e-01 2.51637057e-01 1.29238696 0.83160063 845.25 8.62001785e-02 2.56502939e-01 2.70599757e-01 1.24659448 0.85765154 845.50 1.18231660e-01 2.32049748e-01 2.60433889e-01 1.09956972 0.83989685 845.75 1.27222260e-01 2.11153111e-01 2.46518032e-01 1.02853189 0.84200442 846.00 1.52302603e-01 2.14289072e-01 2.62899010e-01 0.95290238 0.79430407 846.25 1.56841524e-01 2.13417544e-01 2.64851490e-01 0.93702651 0.82093364 846.50 1.71718694e-01 2.16871311e-01 2.76623345e-01 0.90107545 0.86630517 846.75 1.67041860e-01 2.06785929e-01 2.65825889e-01 0.89131681 0.88321841 847.00 1.40875881e-01 2.01674116e-01 2.46005006e-01 0.96105609 0.86764806 847.25 1.30198892e-01 1.93948998e-01 2.33597871e-01 0.97958958 0.83048630 847.50 1.44266837e-01 2.10349548e-01 2.55068330e-01 0.96963480 0.84309583 847.75 1.48308854e-01 2.13424036e-01 2.59894855e-01 0.96349984 0.84152138 848.00 1.41636811e-01 2.24236674e-01 2.65222684e-01 1.00743656 0.87030477 848.25 1.38192896e-01 2.37141289e-01 2.74469065e-01 1.04316097 0.89174270 848.50 1.37621759e-01 2.72796920e-01 3.05545263e-01 1.10356773 0.88182611 848.75 1.33372832e-01 3.02524043e-01 3.30619281e-01 1.15556341 0.87129444 849.00 1.07130097e-01 3.16284683e-01 3.33935411e-01 1.24421088 0.83646264 849.25 1.18802462e-01 3.33027832e-01 3.53583882e-01 1.22813474 0.83826812 849.50 1.42855190e-01 3.64658326e-01 3.91641801e-01 1.19742150 0.81634709 849.75 1.69589515e-01 4.03613556e-01 4.37795051e-01 1.17301708 0.80408005 850.00 1.87807651e-01 4.15692014e-01 4.56148621e-01 1.14645053 0.86847741 850.25 1.84455169e-01 4.23030276e-01 4.61495746e-01 1.15961785 0.86173418 850.50 2.38887165e-01 4.22765035e-01 4.85589696e-01 1.05646511 0.86317161 850.75 2.61573847e-01 4.02998724e-01 4.80446509e-01 0.99507610 0.85760468 851.00 2.62107730e-01 4.26297265e-01 5.00429636e-01 1.01953115 0.87528973 851.25 2.77059531e-01 4.33139850e-01 5.14171288e-01 1.00172881 0.87176659 851.50 2.66023961e-01 4.82443088e-01 5.50926566e-01 1.06687120 0.85250353 851.75 2.47636477e-01 5.03450168e-01 5.61057837e-01 1.11366674 0.85319934 852.00 2.38513370e-01 5.96967600e-01 6.42852193e-01 1.19068521 0.90716521 852.25 2.33192694e-01 6.29641431e-01 6.71436641e-01 1.21610162 0.90524986 852.50 2.20755992e-01 6.44822923e-01 6.81564238e-01 1.24095164 0.90263999 852.75 2.02119058e-01 6.91440219e-01 7.20376076e-01 1.28640387 0.88110446 853.00 1.79219412e-01 7.93189428e-01 8.13184522e-01 1.34857993 0.88647982 853.25 1.87003292e-01 8.25073166e-01 8.45999977e-01 1.34791142 0.86997409 853.50 2.18631998e-01 8.39049073e-01 8.67065913e-01 1.31589334 0.87184776 853.75 2.03576514e-01 8.99630360e-01 9.22376378e-01 1.34825527 0.84193958 854.00 1.34524094e-01 9.48669138e-01 9.58159624e-01 1.42993252 0.82764076 854.25 3.11472384e-02 9.90648152e-01 9.91137685e-01 1.53936541 0.78412057 854.50 -8.52936025e-02 1.13000435e+00 1.13321879e+00 1.64613424 0.83507909 854.75 -1.07309055e-01 1.10846944e+00 1.11365153e+00 1.66730390 0.80731766 855.00 -1.57642944e-01 1.08480245e+00 1.09619690e+00 1.71510565 0.81062326 855.25 -1.10885429e-01 9.37054487e-01 9.43592438e-01 1.68858260 0.78277723 855.50 -1.40165189e-01 8.86368160e-01 8.97382190e-01 1.72763191 0.76890966 855.75 -1.50190957e-01 7.13041198e-01 7.28687226e-01 1.77839598 0.67687176 856.00 -2.34429716e-01 5.79352507e-01 6.24985295e-01 1.95529706 0.68639227 856.25 -1.90022812e-01 4.78420264e-01 5.14776280e-01 1.94887626 0.74635564 856.50 -1.89734131e-01 3.99378921e-01 4.42156718e-01 2.01430420 0.80532192 856.75 -1.48283014e-01 2.87677782e-01 3.23645421e-01 2.04672603 0.77056704 857.00 -1.19226828e-01 2.58682237e-01 2.84835982e-01 2.00267822 0.75074442 857.25 -7.47216392e-02 8.94755886e-02 1.16572743e-01 2.26658011 0.22579102 857.50 -5.44127449e-02 -1.49402355e-02 5.64265668e-02 -2.87362406 0.09635451 857.75 -4.72837623e-02 -4.13031042e-02 6.27829643e-02 -2.42360399 0.10057197 858.00 -8.78682382e-03 -7.58804993e-02 7.63875543e-02 -1.68608105 0.13491879 858.25 -3.09283610e-02 -1.12351683e-01 1.16530958e-01 -1.83942440 0.29655458 858.50 -2.51902112e-02 -1.48689519e-01 1.50808222e-01 -1.73861771 0.40663089 858.75 9.19952651e-03 -2.23262210e-01 2.23451663e-01 -1.52961459 0.57648100 859.00 -3.21535320e-03 -2.35916224e-01 2.35938134e-01 -1.58442470 0.50302419 859.25 7.67366462e-03 -3.19852972e-01 3.19945009e-01 -1.54680970 0.56286466 859.50 1.80265053e-02 -3.54104098e-01 3.54562642e-01 -1.51993287 0.59310227 859.75 -2.48580807e-02 -3.93954199e-01 3.94737679e-01 -1.63381169 0.53355631 860.00 -1.49728001e-02 -3.59251574e-01 3.59563455e-01 -1.61244998 0.47338218 860.25 -1.41437054e-02 -2.29475131e-01 2.29910591e-01 -1.63235348 0.23202057 860.50 2.60761536e-02 -1.86793055e-01 1.88604377e-01 -1.43209354 0.18421068 860.75 3.31549394e-02 -2.33484170e-01 2.35826435e-01 -1.42973859 0.21397308 861.00 1.56288842e-02 -1.86705586e-01 1.87358581e-01 -1.48728232 0.11197816 861.25 -7.22742773e-04 -2.77356028e-01 2.77356969e-01 -1.57340215 0.19243623 861.50 2.12325663e-02 -1.82320943e-01 1.83553121e-01 -1.45486147 0.07049203 861.75 -1.65926032e-03 1.57649524e-01 1.57658256e-01 1.58132093 0.06065788 862.00 -1.39730897e-01 1.95987224e-01 2.40698391e-01 2.19016690 0.14549466 862.25 -2.06500626e-01 1.94353855e-01 2.83577026e-01 2.38648742 0.21677311 862.50 -2.13418367e-01 1.51794736e-01 2.61895096e-01 2.52335332 0.20237367 862.75 -2.51431829e-01 4.89648456e-02 2.56155267e-01 2.94925599 0.20063010 863.00 -3.70342855e-01 -2.07077115e-02 3.70921339e-01 -3.08573584 0.42256600 863.25 -4.38633775e-01 -2.47235637e-02 4.39329994e-01 -3.08528730 0.55506747 863.50 -3.85775431e-01 -5.77656608e-02 3.90076345e-01 -2.99295789 0.47489564 863.75 -3.80415387e-01 -1.00962798e-01 3.93585255e-01 -2.88217185 0.62656994 864.00 -3.41198428e-01 -8.69300114e-02 3.52098273e-01 -2.89212169 0.54038873 864.25 -3.02674544e-01 -4.98894683e-02 3.06758600e-01 -2.97823275 0.42564991 864.50 -3.08844402e-01 -1.26172104e-01 3.33622937e-01 -2.75375480 0.47622457 864.75 -3.67453656e-01 -1.17686395e-01 3.85839704e-01 -2.83163984 0.63999850 865.00 -3.68398286e-01 -7.21062530e-02 3.75388611e-01 -2.94830711 0.60724285 865.25 -3.47954161e-01 -7.38469327e-02 3.55704186e-01 -2.93246390 0.50109235 865.50 -2.64630450e-01 -1.33162896e-01 2.96245898e-01 -2.67538575 0.46132522 865.75 -3.07901474e-01 -1.46694653e-01 3.41061049e-01 -2.69697516 0.54637648 866.00 -3.05808814e-01 -1.44419679e-01 3.38195320e-01 -2.70038654 0.47720303 866.25 -3.17045978e-01 -1.78055969e-01 3.63623542e-01 -2.62988007 0.53507122 866.50 -3.64435977e-01 -2.25160836e-01 4.28381820e-01 -2.58816322 0.56450856 866.75 -3.69376127e-01 -2.30952382e-01 4.35634854e-01 -2.58281366 0.51774030 867.00 -2.82643681e-01 -2.36792475e-01 3.68725002e-01 -2.44423740 0.37002785 867.25 -2.15868283e-01 -2.24154278e-01 3.11198097e-01 -2.33736587 0.26742306 867.50 -2.91804860e-01 -2.13933591e-02 2.92588025e-01 -3.06840966 0.23226107 867.75 -3.37990832e-01 2.86565988e-03 3.38002980e-01 3.13311434 0.36675298 868.00 -4.55566389e-01 2.15603462e-02 4.56076291e-01 3.09430148 0.58395919 868.25 -4.55148449e-01 4.39926682e-02 4.57269577e-01 3.04523633 0.60153366 868.50 -4.57962010e-01 9.75004445e-02 4.68225949e-01 2.93182388 0.56720818 868.75 -4.77022689e-01 8.74424508e-02 4.84970956e-01 2.96029663 0.62087083 869.00 -4.61204136e-01 1.69508769e-01 4.91367966e-01 2.78938244 0.67574281 869.25 -4.42587988e-01 1.72698782e-01 4.75088409e-01 2.76956113 0.67370578 869.50 -4.48935868e-01 1.53144887e-01 4.74338244e-01 2.81284280 0.70239874 869.75 -4.87488443e-01 1.83907015e-01 5.21024733e-01 2.78084725 0.80806518 870.00 -4.81058149e-01 1.96964695e-01 5.19819232e-01 2.75297449 0.81889373 870.25 -4.41022093e-01 1.81287062e-01 4.76828570e-01 2.75158729 0.78932437 870.50 -3.89593327e-01 1.92135404e-01 4.34394951e-01 2.68342465 0.82250262 870.75 -3.63403629e-01 1.80283566e-01 4.05665332e-01 2.68107206 0.82709023 871.00 -3.83917597e-01 1.38919389e-01 4.08278481e-01 2.79440304 0.83219982 871.25 -3.81559516e-01 9.22938807e-02 3.92563148e-01 2.90426522 0.83234361 871.50 -3.78644978e-01 7.69622098e-02 3.86387372e-01 2.94106742 0.83273459 871.75 -3.55245495e-01 9.37692757e-02 3.67412627e-01 2.88352242 0.83134643 872.00 -3.51955671e-01 8.03392406e-02 3.61008570e-01 2.91717250 0.87653793 872.25 -3.50246171e-01 6.66958367e-02 3.56539920e-01 2.95341997 0.87784739 872.50 -3.67213209e-01 3.67124560e-02 3.69043825e-01 3.04194790 0.87134194 872.75 -3.74654373e-01 3.65837798e-02 3.76436279e-01 3.04425450 0.83011290 873.00 -3.43047791e-01 3.52099918e-02 3.44850011e-01 3.03931208 0.81296833 873.25 -3.65093699e-01 2.81843798e-02 3.66179967e-01 3.06454780 0.81408597 873.50 -3.65329658e-01 4.12745024e-03 3.65352973e-01 3.13029526 0.77490339 873.75 -3.58581415e-01 -1.36007880e-02 3.58839258e-01 -3.10368140 0.73395174 874.00 -3.74658361e-01 -3.82559612e-02 3.76606434e-01 -3.03983640 0.79430842 874.25 -3.99516999e-01 -8.94607733e-02 4.09410628e-01 -2.92130420 0.80787854 874.50 -4.41581445e-01 -1.12757463e-01 4.55750389e-01 -2.89158583 0.80980512 874.75 -5.00834011e-01 -1.09863446e-01 5.12742317e-01 -2.92565194 0.85377858 875.00 -5.56854904e-01 -7.64124581e-02 5.62073169e-01 -3.00522285 0.85443310 875.25 -6.03749841e-01 -1.22952153e-01 6.16142112e-01 -2.94069234 0.81722174 875.50 -6.41937946e-01 -1.86328252e-01 6.68432902e-01 -2.85909636 0.73918641 875.75 -6.58817664e-01 -2.51788273e-01 7.05292881e-01 -2.77654032 0.71678819 876.00 -6.64095243e-01 -2.58458392e-01 7.12617171e-01 -2.77044093 0.74010301 876.25 -6.74946249e-01 -1.68650806e-01 6.95697875e-01 -2.89673358 0.74686508 876.50 -7.34893687e-01 -1.49964990e-01 7.50038818e-01 -2.94029294 0.75344884 876.75 -8.34924803e-01 -2.18140332e-01 8.62951117e-01 -2.88603591 0.71061253 877.00 -8.65403603e-01 -2.61319592e-01 9.03997415e-01 -2.84833621 0.68077664 877.25 -9.60678564e-01 -2.49665945e-01 9.92590745e-01 -2.88733232 0.65477084 877.50 -9.81539304e-01 -2.17632274e-01 1.00537715e+00 -2.92339712 0.63486669 877.75 -1.14403066e+00 4.39580267e-03 1.14403911e+00 3.13775029 0.51963408 878.00 -1.12711163e+00 2.33210951e-01 1.15098565e+00 2.93756154 0.53038735 878.25 -1.19422182e+00 4.93556767e-01 1.29219350e+00 2.74968441 0.51452781 878.50 -1.18465060e+00 6.80012972e-01 1.36594827e+00 2.62049529 0.52286091 878.75 -8.72761927e-01 7.71173656e-01 1.16465540e+00 2.41791178 0.47154794 879.00 -7.86272247e-01 7.27341569e-01 1.07109748e+00 2.39510860 0.50274341 879.25 -7.82385308e-01 4.67971864e-01 9.11660263e-01 2.60254577 0.51349330 879.50 -5.83468994e-01 4.21857952e-01 7.20000138e-01 2.51558554 0.45725743 879.75 -5.54254808e-01 3.86459512e-01 6.75684355e-01 2.53270822 0.52991121 880.00 -5.80985347e-01 3.97913933e-01 7.04187099e-01 2.54107640 0.52874666 880.25 -6.81554313e-01 3.55281820e-01 7.68597068e-01 2.66106496 0.64028313 880.50 -7.49420411e-01 2.92088564e-01 8.04329958e-01 2.76995132 0.74169133 880.75 -7.28195602e-01 2.83394399e-01 7.81396967e-01 2.77045420 0.69229829 881.00 -7.92117952e-01 2.74926296e-01 8.38472014e-01 2.80752379 0.69787201 881.25 -9.46279695e-01 1.01869131e-01 9.51747121e-01 3.03435340 0.77040664 881.50 -8.89188226e-01 7.21201182e-02 8.92108184e-01 3.06066199 0.72170276 881.75 -7.83797228e-01 -2.56066793e-02 7.84215402e-01 -3.10893424 0.49673364 882.00 -7.46220763e-01 -1.29477142e-01 7.57370291e-01 -2.96979259 0.38656785 882.25 -5.47281165e-01 -3.22289714e-01 6.35127808e-01 -2.60938055 0.31832268 882.50 -4.21927074e-01 -3.48830774e-01 5.47453527e-01 -2.45074861 0.19418253 882.75 2.06794922e-01 -3.08513769e-01 3.71409323e-01 -0.98028671 0.03901849 883.00 4.02053197e-01 8.42895187e-02 4.10793739e-01 0.20665473 0.04558450 883.25 1.98172335e-01 6.65395267e-01 6.94278860e-01 1.28133477 0.20316881 883.50 3.09169741e-01 8.07009027e-01 8.64204547e-01 1.20493831 0.37961274 883.75 4.80952707e-01 7.58115258e-01 8.97805241e-01 1.00546187 0.49195342 884.00 3.30347963e-01 7.96494729e-01 8.62283961e-01 1.17763755 0.61133638 884.25 2.90714430e-01 7.62406556e-01 8.15952595e-01 1.20650375 0.65415187 884.50 2.05377722e-01 7.69752257e-01 7.96679700e-01 1.31005997 0.70837231 884.75 1.00450916e-01 8.33023609e-01 8.39058234e-01 1.45078984 0.76964772 885.00 1.29520290e-01 8.43583127e-01 8.53468217e-01 1.41845010 0.76376705 885.25 1.16815327e-01 7.65798820e-01 7.74657119e-01 1.41942272 0.75579155 885.50 1.61946398e-01 7.41521729e-01 7.59000073e-01 1.35577518 0.74475626 885.75 2.09122902e-01 7.71018152e-01 7.98875071e-01 1.30593885 0.83112271 886.00 1.95287427e-01 6.82906201e-01 7.10280268e-01 1.29226468 0.79937611 886.25 1.69517288e-01 6.31300884e-01 6.53664223e-01 1.30846389 0.80055148 886.50 1.82622593e-01 5.77857625e-01 6.06028421e-01 1.26469522 0.84208931 886.75 1.73184238e-01 5.52004262e-01 5.78533910e-01 1.26678478 0.84848588 887.00 1.71333017e-01 5.03562384e-01 5.31911719e-01 1.24284101 0.82769955 887.25 1.43348071e-01 4.85222860e-01 5.05954438e-01 1.28353995 0.85277380 887.50 1.08887094e-01 4.68890620e-01 4.81367649e-01 1.34261784 0.84385003 887.75 5.72351867e-02 4.30484443e-01 4.34272636e-01 1.43861625 0.80374552 888.00 -2.25456385e-02 3.90399833e-01 3.91050298e-01 1.62848238 0.86141650 888.25 -3.41153908e-02 3.85117396e-01 3.86625489e-01 1.65915009 0.88721579 888.50 -9.89501264e-02 4.40886676e-01 4.51854168e-01 1.79157234 0.90026228 888.75 -1.15062336e-01 4.52245022e-01 4.66652870e-01 1.81993513 0.91117368 889.00 -9.53388301e-02 4.46416522e-01 4.56483520e-01 1.78120024 0.91232092 889.25 -7.16850269e-02 4.36401687e-01 4.42250128e-01 1.73360623 0.91767546 889.50 -7.86087805e-02 4.12849686e-01 4.20266824e-01 1.75894945 0.88661235 889.75 -9.53765449e-02 4.03005308e-01 4.14137614e-01 1.80318390 0.87118237 890.00 -1.53721655e-01 3.75351027e-01 4.05609098e-01 1.95950059 0.88283140 890.25 -1.60993484e-01 3.69816823e-01 4.03340284e-01 1.98138650 0.88490791 890.50 -1.91858515e-01 3.60677564e-01 4.08531511e-01 2.05966758 0.83046560 890.75 -2.13062637e-01 3.70621847e-01 4.27499989e-01 2.09253951 0.83815527 891.00 -2.50137395e-01 3.87336181e-01 4.61083543e-01 2.14420548 0.90479086 891.25 -2.79905065e-01 3.93420100e-01 4.82831462e-01 2.18917628 0.90257337 891.50 -2.57055698e-01 4.34895882e-01 5.05185174e-01 2.10462682 0.90429638 891.75 -2.34564240e-01 4.25814840e-01 4.86146748e-01 2.07429935 0.90544962 892.00 -2.13314451e-01 4.57030467e-01 5.04360886e-01 2.00748380 0.92672374 892.25 -2.26036264e-01 4.61692501e-01 5.14054820e-01 2.02607472 0.93602021 892.50 -2.03653241e-01 4.29299137e-01 4.75155124e-01 2.01374308 0.92695093 892.75 -1.92761981e-01 4.18743089e-01 4.60980429e-01 2.00221129 0.93060374 893.00 -2.06434638e-01 4.01128080e-01 4.51130798e-01 2.04608345 0.94389655 893.25 -2.05431618e-01 3.90825742e-01 4.41527927e-01 2.05474085 0.93936103 893.50 -1.86994636e-01 3.78969322e-01 4.22592879e-01 2.02917372 0.93094752 893.75 -2.01516581e-01 3.65912142e-01 4.17732723e-01 2.07419518 0.94938067 894.00 -2.16275252e-01 3.63143883e-01 4.22668268e-01 2.10794733 0.96613453 894.25 -2.16306285e-01 3.51284927e-01 4.12540312e-01 2.12272164 0.95727000 894.50 -2.22772837e-01 3.34887049e-01 4.02215206e-01 2.15779522 0.95347906 894.75 -2.39950500e-01 3.23771587e-01 4.02994147e-01 2.20858379 0.95566960 895.00 -2.53292861e-01 3.24255812e-01 4.11459724e-01 2.23393805 0.95470293 895.25 -2.65848254e-01 3.10619504e-01 4.08851771e-01 2.27868529 0.95045601 895.50 -2.75421861e-01 3.12716911e-01 4.16712212e-01 2.29286729 0.96521204 895.75 -2.94946951e-01 3.26248172e-01 4.39808565e-01 2.30584836 0.97301779 896.00 -2.96642496e-01 3.21644204e-01 4.37552014e-01 2.31577943 0.97789782 896.25 -2.99231966e-01 3.10899346e-01 4.31506863e-01 2.33707408 0.96132151 896.50 -2.94403403e-01 3.21125400e-01 4.35654549e-01 2.31280866 0.95326107 896.75 -3.13811683e-01 3.06630489e-01 4.38748252e-01 2.36776829 0.94858173 897.00 -3.38449696e-01 3.01961198e-01 4.53573325e-01 2.41310965 0.95923277 897.25 -3.40551590e-01 2.86803359e-01 4.45232021e-01 2.44166014 0.95498607 897.50 -3.53029412e-01 2.84617820e-01 4.53472237e-01 2.46307318 0.95719458 897.75 -3.58400299e-01 3.01619938e-01 4.68428608e-01 2.44201141 0.96339661 898.00 -3.59542104e-01 2.98528594e-01 4.67321994e-01 2.44864592 0.96378428 898.25 -3.54113563e-01 3.04421112e-01 4.66978188e-01 2.43151088 0.94989537 898.50 -3.56382105e-01 3.03010604e-01 4.67785882e-01 2.43695881 0.95532328 898.75 -3.70945292e-01 3.01494327e-01 4.78015940e-01 2.45911166 0.95168919 899.00 -3.83130992e-01 2.96609091e-01 4.84526892e-01 2.48280041 0.95573608 899.25 -4.02591559e-01 2.73351900e-01 4.86622261e-01 2.54511333 0.95112866 899.50 -4.19942283e-01 2.55594069e-01 4.91609448e-01 2.59484373 0.94238353 899.75 -4.44917741e-01 2.40790516e-01 5.05897093e-01 2.64552898 0.94346447 900.00 -4.59480668e-01 2.30762638e-01 5.14173005e-01 2.67616670 0.93891176 900.25 -4.96705677e-01 2.75662588e-01 5.68072523e-01 2.63493273 0.92896836 900.50 -4.93449029e-01 3.03731794e-01 5.79435024e-01 2.58983353 0.92091027 900.75 -4.65361207e-01 2.97919570e-01 5.52555085e-01 2.57214472 0.89127044 901.00 -4.64038152e-01 3.14050956e-01 5.60320809e-01 2.54662231 0.91420636 901.25 -4.52673794e-01 3.66944495e-01 5.82719337e-01 2.46041215 0.93960687 901.50 -4.64219716e-01 3.86876007e-01 6.04295448e-01 2.44682101 0.94248530 901.75 -5.16008616e-01 3.95978541e-01 6.50433621e-01 2.48705612 0.91525032 902.00 -4.70209507e-01 4.00123544e-01 6.17410586e-01 2.43654885 0.90450723 902.25 -4.31911199e-01 3.94375963e-01 5.84875786e-01 2.40158966 0.95126164 902.50 -4.21332018e-01 3.89874507e-01 5.74040766e-01 2.39495374 0.95734366 902.75 -4.27225854e-01 3.90563577e-01 5.78845263e-01 2.40099544 0.95919123 903.00 -4.43024918e-01 3.96431984e-01 5.94499281e-01 2.41164126 0.95892346 903.25 -4.29823796e-01 3.97423646e-01 5.85400760e-01 2.39534069 0.96752491 903.50 -4.28080194e-01 3.86338351e-01 5.76636778e-01 2.40740323 0.97035714 903.75 -4.46538469e-01 3.72384595e-01 5.81435200e-01 2.44649869 0.97405679 904.00 -4.39194538e-01 3.56250801e-01 5.65514346e-01 2.46009235 0.97285078 904.25 -4.61938031e-01 3.47193428e-01 5.77866785e-01 2.49706722 0.96778326 904.50 -4.67259213e-01 3.69625023e-01 5.95780018e-01 2.47233340 0.96163195 904.75 -4.55412844e-01 3.79875489e-01 5.93048266e-01 2.44638184 0.96460535 905.00 -4.71057343e-01 3.79215587e-01 6.04730917e-01 2.46379178 0.97309248 905.25 -4.77791237e-01 3.81946190e-01 6.11692209e-01 2.46721783 0.97792833 905.50 -4.75562542e-01 3.68608264e-01 6.01690771e-01 2.48222046 0.97308464 905.75 -4.93574073e-01 3.60084563e-01 6.10963385e-01 2.51131170 0.98159945 906.00 -4.99602539e-01 3.50171310e-01 6.10100519e-01 2.53026306 0.97724450 906.25 -5.39328991e-01 3.56640170e-01 6.46581759e-01 2.55733798 0.96934123 906.50 -5.65112575e-01 4.07218177e-01 6.96547820e-01 2.51717683 0.97183903 906.75 -5.66395424e-01 4.32492470e-01 7.12638417e-01 2.48945210 0.98241138 907.00 -5.61473268e-01 4.50067692e-01 7.19592356e-01 2.46588692 0.97907143 907.25 -5.76623239e-01 4.52673326e-01 7.33080828e-01 2.47603937 0.97496674 907.50 -5.99807921e-01 4.91370401e-01 7.75380173e-01 2.45524581 0.96918304 907.75 -6.14665945e-01 5.41179243e-01 8.18956163e-01 2.41968736 0.97676887 908.00 -5.98060187e-01 5.63738176e-01 8.21873907e-01 2.38572804 0.97012737 908.25 -5.73517747e-01 5.82241036e-01 8.17268151e-01 2.34864696 0.97266190 908.50 -5.45973396e-01 6.03980195e-01 8.14173829e-01 2.30579448 0.95251080 908.75 -5.12472303e-01 6.49839566e-01 8.27598527e-01 2.23855566 0.94203306 909.00 -4.75429732e-01 6.62421589e-01 8.15374633e-01 2.19331270 0.93414753 909.25 -4.26688635e-01 6.76256707e-01 7.99616361e-01 2.13366758 0.91812417 909.50 -3.44129379e-01 6.26733379e-01 7.14996334e-01 2.07293614 0.89750273 909.75 -3.41239737e-01 6.14353560e-01 7.02762303e-01 2.07781050 0.88607016 910.00 -3.50623320e-01 5.56315868e-01 6.57589582e-01 2.13316877 0.91965381 910.25 -3.28213876e-01 5.64018206e-01 6.52564851e-01 2.09781615 0.92247596 910.50 -3.11726757e-01 6.06504156e-01 6.81924382e-01 2.04555974 0.93194159 910.75 -2.83572823e-01 6.50616613e-01 7.09729190e-01 1.98182304 0.93708135 911.00 -1.92273087e-01 6.59267502e-01 6.86733267e-01 1.85457189 0.93425115 911.25 -1.54238933e-01 6.50356279e-01 6.68395794e-01 1.80365490 0.92247461 911.50 -4.10466676e-02 6.06115669e-01 6.07503937e-01 1.63841393 0.86470568 911.75 -1.76618740e-02 5.97049094e-01 5.97310273e-01 1.60036965 0.87470790 912.00 -2.33723637e-02 5.50054258e-01 5.50550592e-01 1.61326180 0.84378124 912.25 -3.31349813e-03 4.88208070e-01 4.88219314e-01 1.57758328 0.78478697 912.50 2.72538511e-03 4.16396663e-01 4.16405582e-01 1.56425125 0.64652096 912.75 3.48209965e-02 3.47479435e-01 3.49219787e-01 1.47091952 0.46445768 913.00 -2.14301412e-02 2.60759599e-01 2.61638720e-01 1.65279556 0.34221341 913.25 -3.70700956e-02 2.69025585e-01 2.71567592e-01 1.70772796 0.36649251 913.50 -1.09550272e-01 3.54975992e-01 3.71495918e-01 1.87013628 0.47457753 913.75 -1.69665053e-01 3.67778852e-01 4.05027794e-01 2.00302693 0.55308159 914.00 -2.44688124e-01 2.85789092e-01 3.76228233e-01 2.27886974 0.52558607 914.25 -2.18504447e-01 3.10993521e-01 3.80080470e-01 2.18326599 0.56639636 914.50 -1.56422545e-01 3.55860545e-01 3.88721931e-01 1.98493565 0.62589300 914.75 -1.33908977e-01 3.55478546e-01 3.79863937e-01 1.93105709 0.66837489 915.00 -1.11152488e-01 2.97755061e-01 3.17825348e-01 1.92807730 0.61839750 915.25 -1.17090496e-01 2.56412021e-01 2.81881728e-01 1.99916644 0.59273460 915.50 -9.02274283e-02 2.19085147e-01 2.36937313e-01 1.96146541 0.56535842 915.75 -1.00577302e-01 2.07680987e-01 2.30753518e-01 2.02179509 0.62372317 916.00 -1.02936412e-01 1.50039465e-01 1.81955341e-01 2.17210672 0.56181161 916.25 -1.04224040e-01 9.95557376e-02 1.44131868e-01 2.37909905 0.49169173 916.50 -1.06278279e-01 6.41942686e-02 1.24161091e-01 2.59822208 0.55509306 916.75 -8.75219586e-02 6.06515032e-02 1.06483323e-01 2.53558951 0.45400593 917.00 -7.10633199e-02 4.96172604e-02 8.66710330e-02 2.53206772 0.37501601 917.25 -7.23069542e-02 8.15684962e-03 7.27655813e-02 3.02925891 0.30080813 917.50 -6.83128161e-02 -2.60694548e-02 7.31181052e-02 -2.77703187 0.35846791 917.75 -9.66165790e-02 -2.16560915e-02 9.90138861e-02 -2.92109247 0.51614781 918.00 -9.93442218e-02 -2.26662166e-02 1.01897163e-01 -2.91727406 0.59708295 918.25 -1.11596670e-01 -1.16741138e-02 1.12205622e-01 -3.03736188 0.64669178 918.50 -1.37531653e-01 -8.55255887e-03 1.37797322e-01 -3.07948652 0.84307187 918.75 -1.42922999e-01 9.57494333e-03 1.43243371e-01 3.07469889 0.84953935 919.00 -1.47105473e-01 2.31115748e-02 1.48909922e-01 2.98575762 0.87611788 919.25 -1.59104369e-01 2.68358584e-02 1.61351676e-01 2.97449711 0.88852281 919.50 -1.65644748e-01 3.30640720e-02 1.68912449e-01 2.94457372 0.91074092 919.75 -1.68596159e-01 4.01009647e-02 1.73299602e-01 2.90807950 0.91587123 920.00 -1.78063357e-01 4.10313537e-02 1.82729666e-01 2.91511476 0.93441835 920.25 -1.95941032e-01 4.50038256e-02 2.01042862e-01 2.91582778 0.95630389 920.50 -2.01869152e-01 4.72443076e-02 2.07323851e-01 2.91169604 0.96998876 920.75 -2.07545516e-01 5.25972472e-02 2.14106543e-01 2.89339296 0.96982315 921.00 -2.12729467e-01 6.01620615e-02 2.21073064e-01 2.86597997 0.96959621 921.25 -2.31394677e-01 7.63600240e-02 2.43668525e-01 2.82284595 0.97939185 921.50 -2.34057744e-01 8.43197338e-02 2.48782726e-01 2.79581414 0.97679555 921.75 -2.21769447e-01 1.01421429e-01 2.43860604e-01 2.71266131 0.96704372 922.00 -2.20510441e-01 1.10867272e-01 2.46812493e-01 2.67572702 0.97333322 922.25 -2.15743210e-01 1.20970099e-01 2.47343683e-01 2.63056144 0.97940726 922.50 -2.12633730e-01 1.22897777e-01 2.45595128e-01 2.61752265 0.96437430 922.75 -1.82155924e-01 1.07631578e-01 2.11578206e-01 2.60790893 0.93644581 923.00 -1.78331446e-01 9.76730212e-02 2.03327627e-01 2.64051316 0.93813910 923.25 -1.97962846e-01 9.15295273e-02 2.18098470e-01 2.70851021 0.94503222 923.50 -1.98071757e-01 8.45310121e-02 2.15355318e-01 2.73822406 0.95517306 923.75 -2.10480051e-01 8.73135877e-02 2.27871706e-01 2.74836692 0.96750086 924.00 -2.20490416e-01 9.12571808e-02 2.38629203e-01 2.74917597 0.96467952 924.25 -2.31305716e-01 9.15446486e-02 2.48762451e-01 2.76473520 0.96619336 924.50 -2.36832911e-01 1.00543811e-01 2.57291441e-01 2.74011611 0.94354044 924.75 -2.39881261e-01 1.23195308e-01 2.69666652e-01 2.66714976 0.93260459 925.00 -2.40947186e-01 1.28291059e-01 2.72972787e-01 2.65232740 0.92905155 925.25 -2.41610761e-01 1.49870794e-01 2.84318509e-01 2.58638133 0.88464079 925.50 -2.29070808e-01 1.94237671e-01 3.00335992e-01 2.43829734 0.85430101 925.75 -1.74140191e-01 2.27482342e-01 2.86483895e-01 2.22415067 0.83560146 926.00 -1.46523465e-01 2.14767677e-01 2.59989001e-01 2.16950428 0.79490631 926.25 -1.30022393e-01 1.84367614e-01 2.25604167e-01 2.18502671 0.82215586 926.50 -1.33378922e-01 1.74777413e-01 2.19856956e-01 2.22265155 0.85538613 926.75 -1.34606126e-01 1.81049621e-01 2.25605351e-01 2.21010926 0.88862198 927.00 -1.27285641e-01 1.87509326e-01 2.26630496e-01 2.16716769 0.92128674 927.25 -1.24413408e-01 1.95403714e-01 2.31649105e-01 2.13776442 0.92076399 927.50 -1.20501518e-01 2.16633538e-01 2.47892528e-01 2.07842221 0.91780561 927.75 -1.37607508e-01 2.22094402e-01 2.61269496e-01 2.12549597 0.88443845 928.00 -1.24134238e-01 2.63259645e-01 2.91058327e-01 2.01140784 0.87057559 928.25 -1.05614343e-01 2.93115063e-01 3.11561920e-01 1.91663252 0.89595288 928.50 -7.47519909e-02 3.40126746e-01 3.48244259e-01 1.78713379 0.84031715 928.75 -4.36965448e-02 3.94488067e-01 3.96900772e-01 1.68111433 0.84949500 929.00 9.96678173e-03 4.26198222e-01 4.26314744e-01 1.54741527 0.83446438 929.25 4.69496819e-02 4.85671752e-01 4.87935778e-01 1.47442620 0.82796457 929.50 1.87289782e-01 4.74411391e-01 5.10042773e-01 1.19479502 0.77064817 929.75 2.92885918e-01 4.92564052e-01 5.73063266e-01 1.03434588 0.80376553 930.00 4.04631992e-01 4.71319957e-01 6.21183991e-01 0.86138357 0.73321268 930.25 5.78869140e-01 3.17538485e-01 6.60242508e-01 0.50172904 0.69657142 930.50 6.74235538e-01 8.87142149e-02 6.80046890e-01 0.13082596 0.74738664 930.75 6.62236401e-01 -3.31989600e-02 6.63068037e-01 -0.05008965 0.79024643 931.00 5.81415768e-01 -8.17436466e-02 5.87133988e-01 -0.13967861 0.86776713 931.25 5.45955417e-01 -7.16797270e-02 5.50640809e-01 -0.13054559 0.86800132 931.50 5.87906714e-01 -2.55874621e-02 5.88463272e-01 -0.04349555 0.85246515 931.75 6.66365735e-01 9.08923301e-03 6.66427721e-01 0.01363916 0.88391935 932.00 8.31384911e-01 -4.71092473e-02 8.32718531e-01 -0.05660305 0.88860731 932.25 8.98999472e-01 -1.62801419e-01 9.13621558e-01 -0.17915026 0.85883206 932.50 7.32296893e-01 -4.60988160e-01 8.65314291e-01 -0.56183583 0.82311299 932.75 6.11852405e-01 -5.84852005e-01 8.46413158e-01 -0.76283969 0.84245589 933.00 5.16319759e-01 -6.63683536e-01 8.40869746e-01 -0.90963915 0.82564124 933.25 4.29660337e-01 -6.04205259e-01 7.41398679e-01 -0.95264851 0.78373655 933.50 3.67648030e-01 -5.50236395e-01 6.61759144e-01 -0.98175798 0.84601110 933.75 3.49508453e-01 -4.86363445e-01 5.98920328e-01 -0.94768549 0.86321334 934.00 3.36350462e-01 -4.20260678e-01 5.38284934e-01 -0.89584951 0.82401184 934.25 3.67646768e-01 -4.06030633e-01 5.47745397e-01 -0.83496975 0.81062221 934.50 4.06451113e-01 -4.18779163e-01 5.83591034e-01 -0.80033597 0.82236556 934.75 4.06890468e-01 -4.48727407e-01 6.05736030e-01 -0.83425601 0.83139043 935.00 4.31164316e-01 -4.54957208e-01 6.26808366e-01 -0.81224231 0.87050086 935.25 4.21018234e-01 -4.31746898e-01 6.03043727e-01 -0.79797853 0.84655402 935.50 4.36836978e-01 -4.78584882e-01 6.47973791e-01 -0.83097168 0.82949478 935.75 5.31461906e-01 -4.82289080e-01 7.17672986e-01 -0.73693033 0.84714723 936.00 5.66234162e-01 -4.98925676e-01 7.54684011e-01 -0.72229110 0.89075492 936.25 6.43903344e-01 -5.10753117e-01 8.21876063e-01 -0.67058939 0.85548803 936.50 7.32524710e-01 -5.83268717e-01 9.36373242e-01 -0.67244676 0.82878033 936.75 6.43869119e-01 -6.92261691e-01 9.45406628e-01 -0.82160078 0.79410396 937.00 4.82869256e-01 -8.83046031e-01 1.00644573e+00 -1.07039609 0.75104204 937.25 4.15407450e-01 -9.14326395e-01 1.00426894e+00 -1.14434601 0.72394571 937.50 3.26749077e-01 -8.26859318e-01 8.89078901e-01 -1.19446163 0.67807533 937.75 2.84052931e-01 -9.00429280e-01 9.44171041e-01 -1.26521353 0.70746308 938.00 2.39600236e-01 -1.11177711e+00 1.13730234e+00 -1.35853176 0.72717315 938.25 -1.12909497e-01 -1.09464890e+00 1.10045662e+00 -1.67357961 0.70257484 938.50 -3.48443375e-01 -1.00774557e+00 1.06628510e+00 -1.90369355 0.78019009 938.75 -4.73688379e-01 -9.14520536e-01 1.02991674e+00 -2.04871135 0.76476414 939.00 -5.37286554e-01 -6.99515517e-01 8.82042402e-01 -2.22577098 0.65202619 939.25 -5.43114643e-01 -4.93623813e-01 7.33919604e-01 -2.40389532 0.70084976 939.50 -5.08573631e-01 -3.07363580e-01 5.94238595e-01 -2.59797053 0.70443113 939.75 -4.55427668e-01 -1.61087006e-01 4.83076997e-01 -2.80162106 0.65089586 940.00 -3.85045325e-01 -1.08660396e-01 4.00083722e-01 -2.86654360 0.58924640 940.25 -1.95764050e-01 -2.61358799e-02 1.97501006e-01 -3.00887045 0.23236111 940.50 -7.45644610e-02 -1.49985818e-02 7.60579799e-02 -2.94309234 0.03107251 940.75 1.88859234e-01 1.03650107e-01 2.15432483e-01 0.50193836 0.19359911 941.00 3.19191584e-01 1.18073459e-01 3.40330147e-01 0.35430434 0.45811630 941.25 2.96505594e-01 1.18057967e-01 3.19144561e-01 0.37892295 0.41293203 941.50 3.32679961e-01 1.14968238e-01 3.51985301e-01 0.33273364 0.41069284 941.75 4.49396671e-01 9.66152946e-02 4.59664968e-01 0.21176555 0.47306884 942.00 4.62604466e-01 4.95317471e-02 4.65248628e-01 0.10666511 0.49366510 942.25 4.96574339e-01 -6.84505514e-02 5.01269939e-01 -0.13698226 0.50439538 942.50 5.79336445e-01 -4.84240909e-02 5.81356697e-01 -0.08339159 0.53818270 942.75 6.82628869e-01 1.46456799e-02 6.82785961e-01 0.02145153 0.59294187 943.00 7.51222345e-01 9.42558392e-02 7.57112392e-01 0.12481770 0.57872950 943.25 7.99867244e-01 1.90722393e-01 8.22291091e-01 0.23407184 0.66523276 943.50 7.71678965e-01 1.56851086e-01 7.87458373e-01 0.20052773 0.63544679 943.75 7.85206971e-01 9.75385030e-02 7.91241902e-01 0.12358704 0.67946830 944.00 8.39916217e-01 1.37123724e-01 8.51035938e-01 0.16183111 0.71462926 944.25 9.43550479e-01 8.54970281e-02 9.47416091e-01 0.09036526 0.73456736 944.50 8.92736802e-01 5.29844437e-03 8.92752525e-01 0.00593499 0.75324440 944.75 8.95266912e-01 3.24276801e-02 8.95854005e-01 0.03620541 0.69947009 945.00 9.54829698e-01 7.67088447e-02 9.57906049e-01 0.08016555 0.68648619 945.25 8.46063152e-01 2.66949930e-02 8.46484188e-01 0.03154155 0.67589218 945.50 7.67841603e-01 7.76879772e-02 7.71761718e-01 0.10083395 0.64553728 945.75 9.24845213e-01 2.00688607e-01 9.46369159e-01 0.21368411 0.73533092 946.00 9.49722021e-01 2.07098952e-01 9.72040068e-01 0.21470170 0.77416180 946.25 9.74559477e-01 2.19227073e-01 9.98912750e-01 0.22126677 0.84437765 946.50 9.77710872e-01 2.16288969e-01 1.00134882e+00 0.21771346 0.88897729 946.75 8.67454519e-01 1.67116066e-01 8.83405412e-01 0.19031943 0.87858626 947.00 8.32167170e-01 2.16655141e-01 8.59907931e-01 0.25469634 0.87920825 947.25 7.76452629e-01 2.18564897e-01 8.06628353e-01 0.27439133 0.90380315 947.50 7.11182656e-01 2.39461338e-01 7.50414887e-01 0.32478524 0.88883742 947.75 6.90405263e-01 3.23264620e-01 7.62338141e-01 0.43790559 0.88869154 948.00 6.50550114e-01 3.04587130e-01 7.18323583e-01 0.43788500 0.87797112 948.25 6.05418345e-01 2.64336338e-01 6.60609622e-01 0.41166961 0.91606414 948.50 5.96271594e-01 2.83221692e-01 6.60116914e-01 0.44343833 0.89568872 948.75 5.50287295e-01 2.72728420e-01 6.14163576e-01 0.46013022 0.86464253 949.00 4.76626418e-01 2.56124192e-01 5.41084415e-01 0.49309390 0.87669281 949.25 4.31741988e-01 2.77120559e-01 5.13027239e-01 0.57063594 0.84487234 949.50 3.50692436e-01 3.53048935e-01 4.97623085e-01 0.78874668 0.71607370 949.75 3.16685652e-01 4.83812773e-01 5.78242684e-01 0.99122047 0.72105774 950.00 3.89412225e-01 4.60170336e-01 6.02825529e-01 0.86849213 0.75307879 950.25 3.76228363e-01 4.31550428e-01 5.72523845e-01 0.85377804 0.72086208 950.50 2.35273920e-01 4.56865338e-01 5.13886908e-01 1.09524115 0.62455335 950.75 2.27849224e-01 4.65044564e-01 5.17862641e-01 1.11521988 0.63039111 951.00 1.81373875e-01 4.93450291e-01 5.25727754e-01 1.21856200 0.71057537 951.25 1.90071453e-01 5.30754552e-01 5.63761964e-01 1.22691000 0.70019065 951.50 2.30025721e-01 5.98250088e-01 6.40948516e-01 1.20372511 0.72371762 951.75 1.86965549e-01 6.35832203e-01 6.62750864e-01 1.28480846 0.74863915 952.00 1.89827508e-01 7.53637224e-01 7.77176652e-01 1.32404733 0.74501927 952.25 2.57522488e-01 8.31671015e-01 8.70628800e-01 1.27051488 0.77475659 952.50 1.64458816e-01 7.83844895e-01 8.00911682e-01 1.36398573 0.70827368 952.75 2.71901781e-01 7.78509845e-01 8.24626071e-01 1.23478155 0.72445181 953.00 4.28775028e-01 7.76157688e-01 8.86717983e-01 1.06608718 0.79315168 953.25 4.29852305e-01 7.21727390e-01 8.40037755e-01 1.03362712 0.80149592 953.50 4.07178670e-01 6.43773228e-01 7.61733837e-01 1.00683068 0.79039290 953.75 3.63883837e-01 6.30537174e-01 7.28003142e-01 1.04738428 0.77953100 954.00 2.59896827e-01 6.64176303e-01 7.13215621e-01 1.19780632 0.78378954 954.25 2.50681636e-01 7.34903192e-01 7.76481799e-01 1.24206463 0.82073414 954.50 1.72827609e-01 8.15105461e-01 8.33226437e-01 1.36185973 0.80526214 954.75 1.88306505e-01 8.57894904e-01 8.78318283e-01 1.35472457 0.81303234 955.00 1.62339496e-01 9.05153672e-01 9.19596260e-01 1.39333286 0.79353744 955.25 2.16547840e-01 1.08098342e+00 1.10246003e+00 1.37308843 0.81960053 955.50 2.49046221e-01 1.36817955e+00 1.39066146e+00 1.39074027 0.85982184 955.75 2.55404408e-01 1.37380277e+00 1.39734229e+00 1.38698430 0.79196035 956.00 3.75677510e-01 1.38858166e+00 1.43850360e+00 1.30657412 0.71022815 956.25 4.12673855e-01 1.41149761e+00 1.47058669e+00 1.28635787 0.70915315 956.50 5.42208811e-01 1.57035528e+00 1.66132661e+00 1.23833455 0.77613906 956.75 4.70474967e-01 1.63688070e+00 1.70315152e+00 1.29091886 0.76970183 957.00 4.67058507e-01 1.76338051e+00 1.82418597e+00 1.31187636 0.77002924 957.25 5.54424314e-01 1.49876743e+00 1.59802695e+00 1.21648662 0.65882336 957.50 1.18961306e+00 1.25328496e+00 1.72797640e+00 0.81145635 0.69078758 957.75 1.31290672e+00 1.19010425e+00 1.77202488e+00 0.73637557 0.71708082 958.00 1.14959437e+00 1.14555707e+00 1.62291966e+00 0.78363911 0.61310099 958.25 1.22962402e+00 1.13576219e+00 1.67389694e+00 0.74573757 0.62336230 958.50 1.25419342e+00 1.04581844e+00 1.63301480e+00 0.69504747 0.66095242 958.75 1.21237236e+00 1.13335158e+00 1.65961819e+00 0.75172374 0.67603570 959.00 1.19090144e+00 1.08573646e+00 1.61154271e+00 0.73923787 0.64388753 959.25 1.16165485e+00 1.13774688e+00 1.62601044e+00 0.77500106 0.66890423 959.50 1.32105043e+00 1.23710112e+00 1.80986005e+00 0.75259354 0.73261098 959.75 1.15621053e+00 1.14788944e+00 1.62925534e+00 0.78178675 0.69538336 960.00 1.08834130e+00 1.13979972e+00 1.57595374e+00 0.80848883 0.68008755 960.25 1.06804258e+00 1.12006601e+00 1.54766367e+00 0.80916921 0.60966867 960.50 1.04894070e+00 1.14308733e+00 1.55142684e+00 0.82832134 0.60556447 960.75 9.25741435e-01 9.45927028e-01 1.32354643e+00 0.79618256 0.48029684 961.00 8.99087605e-01 7.92962271e-01 1.19881095e+00 0.72276023 0.41496494 961.25 9.36094551e-01 8.34969148e-01 1.25437095e+00 0.72836141 0.50602296 961.50 7.43814005e-01 6.99853183e-01 1.02130003e+00 0.75495677 0.41622124 961.75 6.78772152e-01 5.18982281e-01 8.54443821e-01 0.65277339 0.28004296 962.00 7.93764577e-01 7.33255888e-01 1.08061390e+00 0.74579355 0.35116543 962.25 4.75185899e-01 5.04174055e-01 6.92815355e-01 0.81498861 0.19461529 962.50 3.28956954e-01 5.02912702e-01 6.00944143e-01 0.99154181 0.14558674 962.75 2.17098326e-01 5.35839186e-01 5.78148178e-01 1.18585326 0.20427091 963.00 2.35371640e-01 4.39624749e-01 4.98667955e-01 1.07923748 0.19851643 963.25 1.78222899e-01 1.36883073e-01 2.24722890e-01 0.65494977 0.04949540 963.50 1.50030649e-01 4.70890814e-02 1.57246867e-01 0.30412620 0.02090979 963.75 1.74336724e-01 9.20592573e-02 1.97150197e-01 0.48583835 0.02480654 964.00 7.24227873e-02 6.29373740e-02 9.59488049e-02 0.71543716 0.00760008 964.25 6.34635404e-02 8.94089574e-02 1.09642978e-01 0.95351552 0.01326631 964.50 1.31500806e-01 1.59011849e-01 2.06342507e-01 0.87981486 0.03832697 964.75 5.28070281e-02 2.15622723e-01 2.21994912e-01 1.33061892 0.04845656 965.00 2.62199555e-02 1.77066610e-01 1.78997404e-01 1.42378503 0.04020156 965.25 9.45634136e-03 3.09407208e-01 3.09551680e-01 1.54024307 0.09565650 965.50 2.51498793e-02 3.37837286e-01 3.38772118e-01 1.49648963 0.15229424 965.75 7.95219016e-02 3.38678628e-01 3.47889272e-01 1.34017346 0.19190881 966.00 1.38677015e-01 4.39632340e-01 4.60985801e-01 1.26523653 0.25889161 966.25 2.21350474e-01 3.68587087e-01 4.29944732e-01 1.02998149 0.22743880 966.50 1.30992584e-01 2.16516265e-01 2.53057998e-01 1.02670764 0.07977562 966.75 -1.61088880e-03 2.34057649e-01 2.34063193e-01 1.57767866 0.05490465 967.00 6.16137258e-02 2.24183779e-01 2.32496490e-01 1.30258279 0.04905140 967.25 1.29367554e-01 2.74662174e-01 3.03603811e-01 1.13061171 0.10782841 967.50 4.09860816e-02 7.05799016e-02 8.16172861e-02 1.04468537 0.00977183 967.75 1.26459438e-01 -7.29159355e-02 1.45975077e-01 -0.52303247 0.03756455 968.00 1.26747347e-01 1.12574682e-02 1.27246299e-01 0.08858572 0.02907311 968.25 4.14658175e-02 1.58264354e-01 1.63606295e-01 1.31455253 0.05762604 968.50 1.48719495e-01 2.34878917e-01 2.78002866e-01 1.00633983 0.18834289 968.75 1.96751347e-01 2.13761067e-01 2.90525191e-01 0.82680981 0.26119315 969.00 1.08466142e-01 1.88122988e-01 2.17152395e-01 1.04778267 0.14896699 969.25 7.71165239e-02 1.81593159e-01 1.97289213e-01 1.16920822 0.08708638 969.50 1.91223110e-01 1.09000114e-01 2.20107479e-01 0.51808014 0.08718869 969.75 1.16917119e-01 6.91123845e-02 1.35816547e-01 0.53386664 0.02785520 970.00 -1.62030739e-01 7.70106783e-02 1.79400682e-01 2.69791232 0.04206930 970.25 -1.04956678e-01 2.04675548e-01 2.30017356e-01 2.04462777 0.06463375 970.50 -2.02898205e-01 2.34625114e-01 3.10188049e-01 2.28380641 0.09393846 970.75 -2.02627766e-01 2.32926534e-01 3.08727683e-01 2.28674268 0.11445530 971.00 -2.59185144e-01 9.94337570e-02 2.77604054e-01 2.77526889 0.09084463 971.25 -6.02867987e-01 1.13415078e-01 6.13443388e-01 2.95564014 0.31767997 971.50 -7.19486014e-01 2.79492699e-01 7.71865463e-01 2.77107256 0.48755264 971.75 -7.67985762e-01 4.64080166e-01 8.97314065e-01 2.59803039 0.59578247 972.00 -6.99969673e-01 4.76898103e-01 8.46988397e-01 2.54351903 0.61404920 972.25 -6.18068409e-01 4.33297936e-01 7.54821608e-01 2.53016117 0.58555812 972.50 -6.10611177e-01 4.30699848e-01 7.47227120e-01 2.52727936 0.57948603 972.75 -5.71118063e-01 3.89128790e-01 6.91083973e-01 2.54349643 0.50050595 973.00 -4.36329884e-01 4.19278958e-01 6.05126939e-01 2.37612026 0.52683765 973.25 -4.38693738e-01 5.43813477e-01 6.98702578e-01 2.24960864 0.62293047 973.50 -3.34675772e-01 5.36367030e-01 6.32216310e-01 2.12865306 0.51439564 973.75 -3.70434907e-01 5.46874437e-01 6.60525298e-01 2.16617058 0.51319959 974.00 -2.81686325e-01 5.53851638e-01 6.21368508e-01 2.04129649 0.47935284 974.25 -2.54610606e-01 5.96554453e-01 6.48616818e-01 1.97419225 0.53160724 974.50 -7.50218842e-02 5.44799488e-01 5.49940693e-01 1.70764117 0.44343783 974.75 -6.53848459e-02 6.19912800e-01 6.23351472e-01 1.67588205 0.50277401 975.00 -1.09550940e-02 7.47453718e-01 7.47533996e-01 1.58545183 0.49881255 975.25 9.02515279e-02 7.16506868e-01 7.22168561e-01 1.44549577 0.43391615 975.50 2.03525826e-01 5.93054604e-01 6.27006001e-01 1.24020807 0.40354487 975.75 2.30349680e-01 5.09205400e-01 5.58883812e-01 1.14597255 0.38824468 976.00 1.72117531e-01 4.55837684e-01 4.87249872e-01 1.20976117 0.44301906 976.25 1.36134266e-01 3.70135116e-01 3.94376143e-01 1.21835628 0.37550571 976.50 2.46358239e-01 3.40231994e-01 4.20059747e-01 0.94408554 0.44700555 976.75 1.87286110e-01 2.91274774e-01 3.46290457e-01 0.99936644 0.34543241 977.00 8.89559266e-02 2.85179908e-01 2.98731881e-01 1.26843160 0.36236717 977.25 4.29549447e-02 2.70548692e-01 2.73937442e-01 1.41334085 0.40774610 977.50 -4.30825429e-02 2.36827786e-01 2.40714573e-01 1.75074361 0.37625252 977.75 -8.89754195e-02 2.22839557e-01 2.39946022e-01 1.95068202 0.27605943 978.00 -2.07426698e-01 2.37838350e-01 3.15583453e-01 2.28800029 0.39684912 978.25 -2.65849758e-01 2.23779509e-01 3.47495845e-01 2.44190664 0.52946206 978.50 -3.20409874e-01 2.07151091e-01 3.81541691e-01 2.56766838 0.62175092 978.75 -3.05401749e-01 1.86766025e-01 3.57982928e-01 2.59272952 0.61566830 979.00 -2.40937644e-01 1.71226709e-01 2.95583380e-01 2.52374269 0.58039696 979.25 -2.46326225e-01 1.47032440e-01 2.86871308e-01 2.60345474 0.52366444 979.50 -2.74249068e-01 1.39765212e-01 3.07809788e-01 2.67027174 0.57363803 979.75 -2.59395263e-01 7.59782276e-02 2.70293533e-01 2.85665747 0.47697413 980.00 -2.33944406e-01 2.21699707e-02 2.34992538e-01 3.04710884 0.44920500 980.25 -1.86249886e-01 -4.08071137e-02 1.90667880e-01 -2.92590217 0.34115820 980.50 -1.84791663e-01 -1.34946027e-01 2.28819556e-01 -2.51084507 0.38010911 980.75 -2.32354370e-01 -2.33883457e-01 3.29681702e-01 -2.35291487 0.44678152 981.00 -1.91241549e-01 -3.01880157e-01 3.57358307e-01 -2.13548577 0.44798912 981.25 -1.81997825e-01 -4.37833547e-01 4.74153375e-01 -1.96474484 0.47346772 981.50 -2.15941804e-01 -4.69142836e-01 5.16455093e-01 -2.00217448 0.47687046 981.75 -2.47185536e-01 -4.40796566e-01 5.05373428e-01 -2.08187071 0.43743148 982.00 -2.25284181e-01 -4.12194069e-01 4.69741325e-01 -2.07098602 0.35807776 982.25 -2.68929207e-01 -2.46512926e-01 3.64817133e-01 -2.39965653 0.15645060 982.50 -3.69276333e-01 -2.08671168e-01 4.24156418e-01 -2.62724445 0.20102886 982.75 -5.84169799e-01 -2.27020085e-01 6.26731579e-01 -2.77093493 0.40309502 983.00 -6.82378032e-01 -2.30586429e-01 7.20284582e-01 -2.81572342 0.51154076 983.25 -5.64349215e-01 3.43708171e-02 5.65394897e-01 3.08076433 0.39020239 983.50 -5.91085712e-01 1.35847020e-01 6.06495451e-01 2.91568928 0.47380826 983.75 -5.97623202e-01 9.35276663e-02 6.04897442e-01 2.98635247 0.59369627 984.00 -6.01525040e-01 1.66428442e-01 6.24124027e-01 2.87166756 0.70300433 984.25 -6.77595407e-01 1.88451637e-01 7.03313269e-01 2.87032976 0.81906002 984.50 -7.56835300e-01 1.39100547e-01 7.69511945e-01 2.95982881 0.83329825 984.75 -7.87245446e-01 1.25839656e-01 7.97239620e-01 2.98308554 0.80967044 985.00 -7.64397728e-01 1.01833067e-01 7.71150997e-01 3.00915247 0.78401761 985.25 -8.39593292e-01 1.10739989e-01 8.46864948e-01 3.01045245 0.76328669 985.50 -8.78221749e-01 4.95183861e-02 8.79616684e-01 3.08526746 0.76597304 985.75 -8.33690886e-01 -5.72919077e-02 8.35657141e-01 -3.07297972 0.72400314 986.00 -7.74398005e-01 -9.35732484e-02 7.80030912e-01 -3.02134211 0.63320021 986.25 -8.46273155e-01 -8.73214290e-02 8.50766293e-01 -3.03877302 0.62351475 986.50 -8.26099484e-01 -1.41004181e-01 8.38046858e-01 -2.97253518 0.62039591 986.75 -8.50833208e-01 -2.10356749e-01 8.76451430e-01 -2.89921692 0.65289922 987.00 -9.20974544e-01 -2.17401786e-01 9.46286239e-01 -2.90977997 0.69905756 987.25 -9.02508930e-01 -2.67365470e-01 9.41279269e-01 -2.85358262 0.64301875 987.50 -9.34248274e-01 -2.86678435e-01 9.77243246e-01 -2.84385911 0.61863239 987.75 -9.57652709e-01 -2.79276874e-01 9.97544126e-01 -2.85783559 0.54545636 988.00 -1.07724822e+00 -2.99144578e-01 1.11801216e+00 -2.87072426 0.56502659 988.25 -8.23447334e-01 -3.75238983e-01 9.04914254e-01 -2.71401473 0.51269767 988.50 -8.88299263e-01 -3.77029977e-01 9.65001132e-01 -2.74019620 0.57461279 988.75 -8.80486720e-01 -3.69449903e-01 9.54856060e-01 -2.74430698 0.54721562 989.00 -9.29929045e-01 -2.47371157e-01 9.62268423e-01 -2.88160270 0.57147918 989.25 -9.22410361e-01 -3.18203304e-01 9.75753154e-01 -2.80940649 0.60208912 989.50 -9.15960511e-01 -2.32926257e-01 9.45112850e-01 -2.89257361 0.62348545 989.75 -7.66825653e-01 -1.96585091e-01 7.91623194e-01 -2.89063508 0.55337556 990.00 -7.41349049e-01 -1.86840836e-01 7.64531171e-01 -2.89470605 0.51531349 990.25 -8.46473526e-01 -1.16685942e-01 8.54478226e-01 -3.00460650 0.60885876 990.50 -8.60874612e-01 4.20057304e-02 8.61898822e-01 3.09283707 0.60322227 990.75 -7.98850915e-01 -8.10325286e-02 8.02950220e-01 -3.04050207 0.59609112 991.00 -7.21488495e-01 -2.32086507e-01 7.57898275e-01 -2.83036891 0.51580487 991.25 -7.35277063e-01 -1.32242848e-01 7.47074648e-01 -2.96364071 0.49867151 991.50 -6.81859457e-01 -2.00031393e-02 6.82152802e-01 -3.11226490 0.49718649 991.75 -6.64786062e-01 -3.06194644e-02 6.65490842e-01 -3.09556606 0.58311798 992.00 -7.04399816e-01 3.45538767e-02 7.05246816e-01 3.09257759 0.70837521 992.25 -7.29926290e-01 5.79483021e-02 7.32222913e-01 3.06236956 0.78408360 992.50 -6.63935075e-01 2.04767708e-02 6.64250768e-01 3.11076090 0.76390142 992.75 -6.41001155e-01 2.82453422e-02 6.41623161e-01 3.09755672 0.70727798 993.00 -5.85331067e-01 -2.00505609e-02 5.85674383e-01 -3.10735097 0.66299543 993.25 -5.22188392e-01 -3.01081671e-02 5.23055655e-01 -3.08399875 0.62039896 993.50 -3.47641741e-01 -1.17959757e-02 3.47841811e-01 -3.10767425 0.34529080 993.75 -2.83030293e-01 5.04950342e-03 2.83075333e-01 3.12375369 0.29850059 994.00 -2.05128590e-01 -2.82193331e-02 2.07060545e-01 -3.00488178 0.19980922 994.25 -2.19236205e-01 -3.16748523e-02 2.21512550e-01 -2.99810732 0.20374691 994.50 -2.62034818e-01 -3.17067685e-02 2.63946141e-01 -3.02117595 0.22525824 994.75 -2.67327057e-01 -5.75424406e-03 2.67388980e-01 -3.12007087 0.22559957 995.00 -2.12871462e-01 -5.55775336e-04 2.12872187e-01 -3.13898181 0.10965762 995.25 -2.08994587e-01 -2.06935015e-02 2.10016567e-01 -3.04289981 0.09554295 995.50 -2.65081952e-01 3.72204819e-02 2.67682285e-01 3.00209341 0.15977710 995.75 -2.68732367e-01 9.98635473e-02 2.86687658e-01 2.78579763 0.21264697 996.00 -3.82374839e-01 5.09772672e-02 3.85757954e-01 3.00905665 0.28467873 996.25 -4.46665405e-01 1.05570420e-01 4.58971783e-01 2.90949950 0.32261709 996.50 -4.25693130e-01 2.13696125e-01 4.76319929e-01 2.67634975 0.33945308 996.75 -4.26042847e-01 2.01518461e-01 4.71298416e-01 2.69977703 0.34729208 997.00 -3.72640959e-01 2.34676181e-01 4.40379602e-01 2.57957426 0.40570482 997.25 -3.91856568e-01 2.76407457e-01 4.79533786e-01 2.52726563 0.51121694 997.50 -3.96341753e-01 3.10083310e-01 5.03228024e-01 2.47769859 0.49494572 997.75 -3.93296939e-01 2.56828042e-01 4.69726650e-01 2.56310220 0.43043204 998.00 -2.48194415e-01 2.33220899e-01 3.40576651e-01 2.38728758 0.32318021 998.25 -2.23329349e-01 2.19743626e-01 3.13310164e-01 2.36428716 0.34381711 998.50 -1.88325286e-01 2.51618032e-01 3.14289751e-01 2.21330921 0.40939335 998.75 -1.59629742e-01 2.16655123e-01 2.69111681e-01 2.20579053 0.35345792 999.00 -1.96181380e-01 1.52144265e-01 2.48263995e-01 2.48195244 0.29382312 999.25 -2.15687440e-01 6.41057845e-02 2.25012496e-01 2.85269183 0.23492494 999.50 -1.75477440e-01 5.94962517e-02 1.85289330e-01 2.81470275 0.15657358 999.75 -2.48589410e-01 5.93970682e-02 2.55586984e-01 2.90705355 0.29473026 1000.00 -2.39678337e-01 0.00000000e+00 2.39678337e-01 3.14159265 0.24906316