========================================================== Mechanical transfer function data ========================================================== Instrumented baffle : NI Triaxial accelerometer position : TOP Triaxial accelerometer axis : X Reference mono-axial accelerometer position : R1 (horizontal, below baffle) Quiet acquisition : SIG0041 Injection acquisition : SIG0042 Analysis parameters -------------------------------------- Sampling frequency : 2000.0 Hz Frequency resolution : 0.250 Hz Window : Hann Window overlap : 50 % FFT length : 8000 samples Transfer function : Triaxial accelerometer / Reference accelerometer Freq[Hz] TF_Real TF_Imag TF_Mag TF_Phase Coherence ----------------------------------------------------------------------------------------------- 0.00 -1.79175011e-01 0.00000000e+00 1.79175011e-01 3.14159265 0.23870442 0.25 -1.74518581e-01 2.75196690e-02 1.76675033e-01 2.98519147 0.23915020 0.50 -8.11869469e-02 1.97091457e-02 8.35450225e-02 2.90343728 0.07908885 0.75 -9.44691741e-02 1.26186954e-02 9.53082175e-02 3.00880394 0.10667520 1.00 -9.81922382e-02 1.54400416e-02 9.93987451e-02 2.98562673 0.10654805 1.25 -1.13634648e-01 6.20087288e-03 1.13803709e-01 3.08707822 0.14171750 1.50 -1.14739366e-01 8.61570188e-03 1.15062385e-01 3.06664398 0.12342239 1.75 -1.23448870e-01 -3.03260083e-03 1.23486113e-01 -3.11703195 0.12491794 2.00 -1.35830294e-01 -1.56061043e-02 1.36723880e-01 -3.02720011 0.12839342 2.25 -1.13514504e-01 -7.82942668e-03 1.13784193e-01 -3.07272880 0.11232396 2.50 -9.27659036e-02 -3.70448522e-03 9.28398410e-02 -3.10168017 0.06472542 2.75 -1.13631657e-01 -1.63066424e-02 1.14795732e-01 -2.99906135 0.08451339 3.00 -1.21326623e-01 -2.87399171e-02 1.24684130e-01 -2.90899931 0.08794801 3.25 -1.39514880e-01 -3.79978387e-02 1.44596810e-01 -2.87568538 0.13164128 3.50 -1.41274500e-01 -5.62433806e-02 1.52058548e-01 -2.76271305 0.14237663 3.75 -1.03371986e-01 -2.85795163e-02 1.07249971e-01 -2.87185794 0.06730771 4.00 -8.83017843e-02 -3.09325739e-02 9.35629694e-02 -2.80464597 0.05069454 4.25 -1.27839062e-01 -5.61850672e-02 1.39640923e-01 -2.72750607 0.09178950 4.50 -1.22251532e-01 -5.91661516e-02 1.35816312e-01 -2.69085057 0.08336632 4.75 -1.17448192e-01 -3.25789179e-02 1.21882992e-01 -2.87100612 0.06476247 5.00 -1.20722452e-01 -4.00811990e-02 1.27202252e-01 -2.82103254 0.06492837 5.25 -1.17336787e-01 -3.33666385e-02 1.21988746e-01 -2.86453960 0.05938907 5.50 -1.16056755e-01 -5.50069299e-02 1.28432600e-01 -2.69898849 0.06259614 5.75 -1.46499689e-01 -6.80000773e-02 1.61512134e-01 -2.70702147 0.09460943 6.00 -1.29664302e-01 -6.41353345e-02 1.44658814e-01 -2.68225348 0.07677891 6.25 -9.17192237e-02 -5.93244018e-02 1.09232782e-01 -2.56746715 0.04169011 6.50 -9.55363332e-02 -6.26300512e-02 1.14235346e-01 -2.56131690 0.04409266 6.75 -1.08387305e-01 -6.51427550e-02 1.26457054e-01 -2.60042473 0.05260231 7.00 -1.16474822e-01 -5.58487934e-02 1.29172256e-01 -2.69448530 0.04962887 7.25 -1.17253128e-01 -6.38695368e-02 1.33520088e-01 -2.64281608 0.04918269 7.50 -8.60973777e-02 -6.53827733e-02 1.08109507e-01 -2.49209951 0.03054817 7.75 -9.75083765e-02 -1.45478196e-02 9.85876389e-02 -2.99348951 0.02287841 8.00 -1.16258860e-01 -2.15651185e-02 1.18242027e-01 -2.95818496 0.03186140 8.25 -1.12207260e-01 -2.12024287e-02 1.14192872e-01 -2.95483686 0.02933310 8.50 -1.21249496e-01 -4.07445537e-02 1.27912309e-01 -2.81740902 0.03509494 8.75 -8.79122541e-02 -6.68756735e-02 1.10457775e-01 -2.49127272 0.02655798 9.00 -9.75366891e-02 -5.86629752e-02 1.13818937e-01 -2.60011117 0.02644541 9.25 -7.08213193e-02 -1.39511856e-02 7.21823721e-02 -2.94709172 0.00876590 9.50 -8.19746150e-02 -1.94172926e-02 8.42429152e-02 -2.90900970 0.01230861 9.75 -9.96026280e-02 -2.23265087e-02 1.02074269e-01 -2.92108186 0.01727848 10.00 -1.19403963e-01 -4.90115940e-02 1.29071463e-01 -2.75209421 0.02677196 10.25 -1.02680160e-01 -5.43983774e-02 1.16199822e-01 -2.65440218 0.01980203 10.50 -8.60686573e-02 -5.30957349e-02 1.01128487e-01 -2.58883944 0.01574020 10.75 -5.19798805e-02 -5.40340228e-02 7.49772205e-02 -2.33682076 0.00867138 11.00 -1.10522945e-01 -7.84829517e-02 1.35554030e-01 -2.52411662 0.02831045 11.25 -1.15254960e-01 -1.23490248e-01 1.68918759e-01 -2.32171411 0.03844902 11.50 -9.83941874e-02 -9.05890525e-02 1.33745252e-01 -2.39747170 0.02385166 11.75 -8.12964276e-02 -6.47569974e-02 1.03935450e-01 -2.46895644 0.01417377 12.00 -9.19876733e-02 -4.83756013e-02 1.03932338e-01 -2.65744647 0.01286240 12.25 -8.83032888e-02 -4.29379210e-02 9.81892860e-02 -2.68900134 0.01049891 12.50 -4.58303834e-02 -1.05895994e-01 1.15387978e-01 -1.97924389 0.01549818 12.75 -3.16907059e-02 -9.53154743e-02 1.00445709e-01 -1.89178073 0.01221070 13.00 -6.49228966e-02 -1.00662265e-01 1.19782612e-01 -2.14361866 0.01633105 13.25 -6.21298248e-02 -9.66210367e-02 1.14872712e-01 -2.14225318 0.01330651 13.50 -8.03681771e-02 -8.17024361e-02 1.14605113e-01 -2.34796210 0.01349320 13.75 -1.05052212e-01 -7.74007867e-02 1.30486969e-01 -2.50660359 0.01575790 14.00 -6.07348745e-02 -1.19635539e-01 1.34169248e-01 -2.04055777 0.01615642 14.25 -6.54087832e-02 -1.30496957e-01 1.45971794e-01 -2.03542619 0.01767353 14.50 -1.22813245e-02 -3.09429205e-02 3.32910688e-02 -1.94862965 0.00084817 14.75 -4.49750021e-02 -1.65149532e-02 4.79113191e-02 -2.78967522 0.00174986 15.00 -3.93929975e-02 -8.33898311e-02 9.22262012e-02 -2.01211764 0.00712452 15.25 -6.19291994e-02 -7.98144301e-02 1.01022616e-01 -2.23067768 0.00865648 15.50 2.83005111e-02 -1.02957247e-01 1.06775998e-01 -1.30254509 0.00850408 15.75 4.48886994e-02 -9.30465587e-02 1.03308554e-01 -1.12130109 0.00791144 16.00 -8.39195266e-02 -1.50410310e-01 1.72237477e-01 -2.07971302 0.02019559 16.25 -8.38118510e-02 -1.47484633e-01 1.69635325e-01 -2.08756201 0.01931065 16.50 -9.02047671e-02 -1.14017978e-01 1.45385691e-01 -2.24011458 0.01322297 16.75 -1.00261538e-01 -8.35675082e-02 1.30521662e-01 -2.44675887 0.00980852 17.00 4.54885373e-03 -1.25482872e-01 1.25565294e-01 -1.53456140 0.00893073 17.25 -1.74798927e-02 -1.23570306e-01 1.24800509e-01 -1.71132104 0.00886784 17.50 -7.22301049e-02 -1.40208311e-01 1.57719874e-01 -2.04650046 0.01446382 17.75 -8.09508818e-02 -1.39811934e-01 1.61556250e-01 -2.09563030 0.01507545 18.00 -9.04329719e-02 -1.78398452e-01 2.00010325e-01 -2.03996116 0.02195862 18.25 -7.54439737e-02 -1.41295415e-01 1.60175489e-01 -2.06122971 0.01384126 18.50 3.83541013e-02 -6.32534310e-02 7.39731953e-02 -1.02571635 0.00319149 18.75 3.41710165e-04 -3.36714047e-02 3.36731386e-02 -1.56064830 0.00061880 19.00 8.02285040e-02 -9.45255890e-02 1.23982659e-01 -0.86702895 0.00792737 19.25 1.67211430e-02 -9.96995741e-02 1.01092046e-01 -1.40462754 0.00521598 19.50 7.25977972e-02 -8.62203468e-02 1.12713745e-01 -0.87096325 0.00701477 19.75 -9.80846681e-03 -1.40390522e-01 1.40732743e-01 -1.64054857 0.01074348 20.00 1.13477012e-01 -2.12469669e-01 2.40874226e-01 -1.08025343 0.03018054 20.25 -1.92273602e-02 -1.90882221e-01 1.91848153e-01 -1.67118663 0.01907047 20.50 -4.92622506e-02 -2.40392810e-01 2.45388412e-01 -1.77292197 0.02785680 20.75 3.27268488e-02 -2.29948029e-01 2.32265242e-01 -1.42942296 0.02305452 21.00 2.57257570e-01 -1.19312468e-01 2.83578776e-01 -0.43425907 0.02723843 21.25 1.58483389e-01 -8.65140201e-02 1.80559299e-01 -0.49967995 0.01418797 21.50 -6.79899277e-02 -1.58486829e-02 6.98126852e-02 -2.91257880 0.00248503 21.75 -1.21973097e-01 -1.37888587e-01 1.84094266e-01 -2.29502489 0.01482647 22.00 -1.17297735e-01 -1.21295648e-01 1.68734682e-01 -2.33943988 0.01158976 22.25 -9.48457254e-02 -5.52442983e-02 1.09761761e-01 -2.61416646 0.00482520 22.50 -7.95595175e-02 -4.17634464e-02 8.98548957e-02 -2.65819788 0.00311307 22.75 -5.05904156e-02 -1.41784755e-01 1.50540050e-01 -1.91352627 0.00864296 23.00 8.86758889e-02 -1.59081662e-01 1.82127396e-01 -1.06227141 0.01288954 23.25 1.48762423e-01 -1.84482323e-01 2.36989422e-01 -0.89217865 0.02173047 23.50 1.14180188e-01 -1.33332237e-01 1.75540881e-01 -0.86262242 0.01332784 23.75 2.27276638e-01 2.60475391e-02 2.28764386e-01 0.11410934 0.02044936 24.00 3.20997042e-01 1.37340239e-01 3.49143870e-01 0.40428650 0.04703473 24.25 1.01138577e-01 -1.52712328e-01 1.83166773e-01 -0.98583563 0.01064557 24.50 9.53842670e-02 -3.23300555e-01 3.37077747e-01 -1.28390281 0.03054946 24.75 1.72892197e-01 -6.40268606e-02 1.84366892e-01 -0.35466859 0.01035023 25.00 1.69753594e-01 -1.10947897e-02 1.70115775e-01 -0.06526538 0.00930930 25.25 1.76837862e-01 -7.04567450e-02 1.90356987e-01 -0.37914847 0.01010666 25.50 1.29373843e-01 -7.79196509e-02 1.51026697e-01 -0.54209640 0.00607672 25.75 1.45057047e-01 -1.04498846e-01 1.78777951e-01 -0.62428530 0.00917308 26.00 2.89558825e-01 -8.08547725e-03 2.89671690e-01 -0.02791618 0.02268643 26.25 1.15541322e-01 -3.79463304e-02 1.21612997e-01 -0.31732400 0.00472146 26.50 2.17494152e-02 -4.91130896e-02 5.37134307e-02 -1.15390962 0.00089857 26.75 -7.69671912e-02 -1.14688722e-01 1.38121148e-01 -2.16185942 0.00636795 27.00 -6.32604479e-02 -5.26155529e-02 8.22817154e-02 -2.44780191 0.00204377 27.25 4.78445036e-02 -5.21850438e-02 7.07981308e-02 -0.82876354 0.00147015 27.50 2.57996637e-02 -1.04867879e-01 1.07994883e-01 -1.32956643 0.00346394 27.75 3.40005767e-02 -1.40144545e-01 1.44210030e-01 -1.33278423 0.00611525 28.00 -2.59778719e-02 -1.55302029e-01 1.57459741e-01 -1.73653512 0.00727729 28.25 8.84509138e-02 -8.11482573e-02 1.20035844e-01 -0.74236642 0.00450982 28.50 3.21104544e-02 -1.14235762e-01 1.18662929e-01 -1.29677777 0.00429571 28.75 7.60388835e-02 -1.63270615e-01 1.80108871e-01 -1.13494434 0.00894737 29.00 2.39870734e-02 -1.28901350e-01 1.31114217e-01 -1.38681218 0.00475097 29.25 -3.65851970e-02 -1.20005400e-01 1.25458251e-01 -1.86670853 0.00414660 29.50 -5.60188076e-02 -7.99287576e-02 9.76048826e-02 -2.18209872 0.00247088 29.75 -9.51906169e-02 4.23722307e-03 9.52848760e-02 3.09710899 0.00215602 30.00 -7.80191952e-02 -8.90345531e-02 1.18381360e-01 -2.29035080 0.00320584 30.25 -1.19897751e-01 -6.21476889e-02 1.35047421e-01 -2.66338166 0.00442308 30.50 -1.10989624e-01 -4.24142528e-02 1.18817783e-01 -2.77657167 0.00337051 30.75 -1.65932150e-01 2.62415736e-03 1.65952899e-01 3.12577933 0.00540250 31.00 4.10490411e-02 -1.29813166e-01 1.36148749e-01 -1.26452937 0.00365974 31.25 1.99015416e-01 -1.97535131e-01 2.80405535e-01 -0.78166528 0.01505742 31.50 2.76092040e-02 -5.48059109e-02 6.13673856e-02 -1.10414265 0.00078919 31.75 -1.22628439e-01 6.29178538e-03 1.22789742e-01 3.09032989 0.00339371 32.00 -1.77272441e-01 -1.06229510e-01 2.06664528e-01 -2.60172896 0.00758713 32.25 -3.25550151e-01 -1.88077450e-01 3.75973440e-01 -2.61771520 0.01972787 32.50 -2.87184848e-01 -1.39569752e-01 3.19303700e-01 -2.68921351 0.01491695 32.75 -2.58246801e-01 -2.37586692e-01 3.50911451e-01 -2.39783784 0.02105273 33.00 1.28228450e-01 -2.16828857e-01 2.51907302e-01 -1.03673849 0.01200637 33.25 2.69032270e-01 -8.12663037e-02 2.81038386e-01 -0.29335386 0.01392767 33.50 2.69509798e-02 -4.80812419e-02 5.51195168e-02 -1.05990460 0.00045268 33.75 -2.51364965e-02 -8.37536687e-03 2.64950982e-02 -2.81996618 0.00009981 34.00 -4.89720556e-02 -1.55416675e-01 1.62949701e-01 -1.87604965 0.00413046 34.25 -2.58750460e-02 -1.50448647e-01 1.52657503e-01 -1.74111597 0.00341405 34.50 -4.54169367e-02 -2.58293892e-01 2.62256426e-01 -1.74485143 0.00998650 34.75 -2.12219612e-02 -1.29726599e-01 1.31450987e-01 -1.73294991 0.00259362 35.00 -5.14700097e-02 -2.00726946e-01 2.07220821e-01 -1.82180632 0.00667918 35.25 3.56535433e-03 -1.72781703e-01 1.72818485e-01 -1.55016423 0.00574263 35.50 -1.70875353e-01 -2.06995078e-01 2.68412646e-01 -2.26089644 0.01252952 35.75 -1.28265759e-01 -3.38662066e-01 3.62138233e-01 -1.93284416 0.02128192 36.00 3.81592913e-02 -4.43444675e-01 4.45083488e-01 -1.48495581 0.02905957 36.25 1.27010969e-01 -1.12429194e+00 1.13144339e+00 -1.45830352 0.17842978 36.50 2.34121923e-01 -1.76891929e+00 1.78434541e+00 -1.43920805 0.41362805 36.75 1.43052469e-01 -1.04041661e+00 1.05020509e+00 -1.43415771 0.15312658 37.00 -9.95753628e-02 -2.05886848e-01 2.28702092e-01 -2.02127146 0.00783904 37.25 -2.56956140e-01 -1.66532774e-01 3.06201931e-01 -2.56655564 0.01371462 37.50 2.08971870e-01 -2.12820818e-01 2.98264887e-01 -0.79452312 0.01386548 37.75 1.90171210e-01 -3.14376224e-01 3.67420058e-01 -1.02676995 0.02114830 38.00 2.22433795e-01 -1.53145229e-01 2.70056020e-01 -0.60296473 0.01229721 38.25 1.46294678e-01 -1.34832499e-01 1.98952094e-01 -0.74464851 0.00643848 38.50 1.14447439e-01 -3.94137313e-01 4.10417395e-01 -1.28819346 0.03048935 38.75 1.42739346e-01 -4.12323155e-01 4.36331187e-01 -1.23752582 0.03801738 39.00 1.70365466e-01 -2.37373386e-01 2.92182335e-01 -0.94828249 0.01638734 39.25 1.06472776e-01 -1.78434399e-01 2.07786637e-01 -1.03280282 0.00700704 39.50 8.50404932e-02 -2.88412470e-01 3.00688607e-01 -1.28406435 0.01366815 39.75 1.06489690e-01 -2.46867355e-01 2.68855993e-01 -1.16354768 0.01135847 40.00 5.58765415e-02 -2.79693881e-01 2.85220713e-01 -1.37361473 0.01772479 40.25 1.18312560e-01 -3.56912509e-01 3.76011172e-01 -1.25070662 0.02932723 40.50 2.91543624e-01 -3.84507781e-01 4.82539033e-01 -0.92205162 0.05541051 40.75 1.40610424e-01 -2.38257912e-01 2.76655243e-01 -1.03764312 0.01604670 41.00 3.11273917e-01 1.32668667e-01 3.38367295e-01 0.40289674 0.02697284 41.25 3.14459200e-01 7.67515520e-02 3.23690268e-01 0.23939423 0.02233904 41.50 4.47323785e-01 -9.49313197e-02 4.57286042e-01 -0.20911804 0.04564825 41.75 1.60035642e-01 -2.53837491e-01 3.00074788e-01 -1.00827681 0.01630456 42.00 -2.14264643e-01 -2.44759261e-01 3.25294380e-01 -2.28985835 0.01922316 42.25 1.51219181e-01 -8.91091476e-02 1.75521170e-01 -0.53249352 0.00529717 42.50 1.70695664e-01 1.24895242e-01 2.11508466e-01 0.63167528 0.00903502 42.75 3.24921039e-01 9.95727701e-02 3.39835869e-01 0.29736569 0.02937465 43.00 5.08888838e-01 2.00791548e-01 5.47069552e-01 0.37581537 0.09229359 43.25 5.20578489e-01 -1.35028325e-01 5.37805366e-01 -0.25378845 0.04886173 43.50 5.76340825e-01 -1.52595660e-01 5.96199784e-01 -0.25882741 0.05649262 43.75 4.12718556e-01 -2.91151280e-01 5.05079869e-01 -0.61437267 0.02614497 44.00 -1.00821578e-01 -5.03042183e-01 5.13046224e-01 -1.76859926 0.01965790 44.25 -3.89810152e-01 -5.45497072e-01 6.70461789e-01 -2.19125140 0.04202005 44.50 -4.46660926e-01 -2.99971407e-01 5.38041660e-01 -2.55019180 0.03422839 44.75 -2.54227268e-01 -2.67061097e-01 3.68718230e-01 -2.33158002 0.01500132 45.00 -2.55258809e-01 -1.06219919e-01 2.76477360e-01 -2.74726200 0.00936322 45.25 1.13055838e-01 -2.66953396e-01 2.89906430e-01 -1.17019347 0.01229141 45.50 4.43495449e-02 -8.44385881e-02 9.53769223e-02 -1.08717029 0.00159666 45.75 -2.01944081e-01 -1.85490320e-01 2.74204433e-01 -2.39863749 0.01541777 46.00 -3.31683437e-01 -2.10221013e-01 3.92691707e-01 -2.57669015 0.03375754 46.25 -2.64753836e-01 -1.22281707e-01 2.91628890e-01 -2.70891205 0.01673560 46.50 -2.28507036e-01 -2.24213112e-01 3.20135885e-01 -2.36567893 0.02072367 46.75 -1.79444281e-01 -1.11922336e-01 2.11487255e-01 -2.58391693 0.01002186 47.00 -1.10628136e-01 -3.54786632e-01 3.71634415e-01 -1.87305789 0.02543262 47.25 -9.15190416e-03 -4.99308727e-01 4.99392593e-01 -1.58912342 0.02739710 47.50 2.50189817e-02 -4.46608426e-01 4.47308658e-01 -1.51483487 0.02210046 47.75 -8.61889814e-02 -1.14613066e-01 1.43403959e-01 -2.21557596 0.00280017 48.00 -1.12893089e-01 -2.08335393e-01 2.36956717e-01 -2.06738514 0.00794069 48.25 -1.79975108e-01 -1.09849264e-01 2.10850421e-01 -2.59359170 0.00640793 48.50 -7.78817320e-02 -1.88938296e-01 2.04360573e-01 -1.96178168 0.00536560 48.75 -5.79021784e-03 -4.79065916e-02 4.82552396e-02 -1.69107763 0.00031119 49.00 -2.09199394e-01 1.60458308e-02 2.09813858e-01 3.06504140 0.00637612 49.25 -4.14916058e-01 4.81468604e-02 4.17700198e-01 3.02606932 0.02522320 49.50 -2.19979177e-01 -8.64635694e-02 2.36361560e-01 -2.76708901 0.00664202 49.75 -3.77363139e-01 6.23140616e-02 3.82473504e-01 2.97793926 0.01383999 50.00 -3.63442148e-01 2.12378086e-02 3.64062137e-01 3.08322385 0.01293315 50.25 -4.80202983e-01 2.53914333e-01 5.43201062e-01 2.65519905 0.05300664 50.50 -4.98074653e-01 2.27377978e-01 5.47520872e-01 2.71333503 0.05019536 50.75 -6.70326568e-01 1.00711529e-01 6.77849924e-01 2.99246557 0.06588783 51.00 -3.99754306e-01 -1.15998347e-01 4.16244065e-01 -2.85917464 0.02319535 51.25 -1.36707397e-01 -1.21538389e-01 1.82922094e-01 -2.41486572 0.00541908 51.50 2.87475587e-02 -1.52148943e-01 1.54840960e-01 -1.38405424 0.00273457 51.75 -3.60570335e-03 1.06015235e-01 1.06076535e-01 1.60479440 0.00113296 52.00 3.97492360e-02 -5.55277338e-02 6.82885861e-02 -0.94951528 0.00046955 52.25 -1.09208557e-01 -4.84484946e-02 1.19472865e-01 -2.72404632 0.00155464 52.50 -1.51642853e-01 -8.09456764e-02 1.71894611e-01 -2.65127864 0.00317995 52.75 -3.22385953e-01 5.92915126e-02 3.27792901e-01 2.95971049 0.01573971 53.00 -4.37381370e-01 8.40307879e-03 4.37462083e-01 3.12238277 0.03612017 53.25 -6.29890535e-01 -2.22689860e-02 6.30284058e-01 -3.10625363 0.10190868 53.50 -9.08717533e-01 -1.87939943e-01 9.27948801e-01 -2.93764916 0.15818165 53.75 -1.13353021e+00 -1.40958218e-01 1.14226090e+00 -3.01787446 0.20512969 54.00 -5.96526039e-01 -2.56024922e-01 6.49147192e-01 -2.73617569 0.05816535 54.25 -6.91467631e-01 -2.74558543e-01 7.43982445e-01 -2.76361782 0.08141607 54.50 -4.00624635e-01 -9.47265338e-02 4.11671245e-01 -2.90940977 0.02621886 54.75 -4.41448609e-01 -3.41081181e-02 4.42764315e-01 -3.06448178 0.03284527 55.00 -7.43435229e-01 -5.86524363e-01 9.46946022e-01 -2.47363327 0.09918224 55.25 -1.01091122e+00 -8.89130845e-01 1.34628940e+00 -2.42020045 0.17176011 55.50 -1.10858808e+00 -3.16263321e-01 1.15281829e+00 -2.86369012 0.13900103 55.75 -1.28336924e+00 -1.08029795e-01 1.28790801e+00 -3.05761392 0.17122772 56.00 -1.42920793e+00 1.44587888e-02 1.42928106e+00 3.13147635 0.21163672 56.25 -1.48429108e+00 -6.84005348e-02 1.48586629e+00 -3.09554227 0.26391086 56.50 -1.52970283e+00 2.13523067e-01 1.54453321e+00 3.00290408 0.36117090 56.75 -1.68690962e+00 3.29988630e-01 1.71888236e+00 2.94841480 0.41523037 57.00 -2.34057980e+00 5.82019043e-01 2.41185820e+00 2.89787135 0.52847078 57.25 -2.78237658e+00 8.33721290e-01 2.90460163e+00 2.85046288 0.63448693 57.50 -3.98475187e+00 1.30415743e+00 4.19274064e+00 2.82529365 0.73498254 57.75 -4.04925738e+00 2.23133871e+00 4.62334919e+00 2.63794452 0.66493466 58.00 -1.03752002e+00 3.84104040e+00 3.97869817e+00 1.83461471 0.50790946 58.25 6.07344266e-01 2.85996809e+00 2.92374495e+00 1.36154441 0.47831295 58.50 5.07574200e-01 1.18208774e+00 1.28645365e+00 1.16521495 0.36483982 58.75 3.23892261e-01 6.89779981e-01 7.62038462e-01 1.13179687 0.23276393 59.00 -6.71549819e-02 4.79664626e-01 4.84342797e-01 1.70989622 0.19255165 59.25 -2.15462169e-01 3.65463780e-01 4.24249597e-01 2.10350265 0.18009252 59.50 -2.76111065e-01 1.20487108e-01 3.01254815e-01 2.73012947 0.14262690 59.75 -3.82805842e-01 4.58486250e-02 3.85541708e-01 3.02239055 0.20390005 60.00 -6.20536388e-01 5.70087657e-02 6.23149588e-01 3.04997968 0.42510542 60.25 -6.00135292e-01 -4.81167980e-03 6.00154581e-01 -3.13357517 0.33334637 60.50 -6.83710230e-01 -5.53460284e-02 6.85946690e-01 -3.06081924 0.39549818 60.75 -8.02145680e-01 -5.87315841e-02 8.04292914e-01 -3.06850497 0.43558423 61.00 -1.02454470e+00 -1.85971199e-02 1.02471347e+00 -3.12344305 0.54562614 61.25 -1.03910398e+00 -6.61673174e-02 1.04120853e+00 -3.07800123 0.47514671 61.50 -9.82929262e-01 -1.64955621e-01 9.96674616e-01 -2.97532160 0.48216026 61.75 -1.09466423e+00 -2.40166650e-01 1.12070058e+00 -2.92561706 0.49820589 62.00 -1.05555063e+00 -2.13711455e-01 1.07696784e+00 -2.94182858 0.58708567 62.25 -1.22101739e+00 -6.13184298e-02 1.22255610e+00 -3.09141568 0.62474464 62.50 -1.48101011e+00 -4.05823720e-02 1.48156602e+00 -3.11419769 0.78359658 62.75 -1.48626731e+00 -7.89170103e-02 1.48836098e+00 -3.08854502 0.67837858 63.00 -1.50925634e+00 -2.06619598e-01 1.52333396e+00 -3.00553684 0.77485526 63.25 -1.67781940e+00 -1.24441227e-01 1.68242788e+00 -3.06755978 0.75131799 63.50 -1.95073328e+00 -7.66188718e-03 1.95074832e+00 -3.13766498 0.81133714 63.75 -2.12709959e+00 2.22639597e-01 2.13871949e+00 3.03730423 0.71902454 64.00 -2.48183158e+00 9.18996906e-01 2.64651532e+00 2.78695786 0.75957217 64.25 -1.53983581e+00 1.73537965e+00 2.32005104e+00 2.29656116 0.65790365 64.50 -5.80009017e-01 2.14938140e+00 2.22626388e+00 1.83436767 0.71269369 64.75 4.34731581e-01 1.18020796e+00 1.25772905e+00 1.21786702 0.50677978 65.00 6.47771740e-01 6.60227830e-01 9.24937303e-01 0.79492088 0.59146302 65.25 3.88750865e-01 2.37609178e-01 4.55615360e-01 0.54862283 0.32736819 65.50 2.92983284e-01 -4.75276850e-04 2.92983669e-01 -0.00162220 0.18541627 65.75 1.65089139e-01 -2.48343284e-01 2.98209340e-01 -0.98411361 0.12154722 66.00 5.47057024e-02 -2.73177497e-01 2.78601254e-01 -1.37315368 0.16963109 66.25 7.98230268e-02 -3.70546532e-01 3.79046763e-01 -1.35861903 0.23882596 66.50 1.00588026e-01 -3.85499500e-01 3.98406596e-01 -1.31555822 0.25982505 66.75 1.48524059e-02 -4.21205372e-01 4.21467151e-01 -1.53554926 0.29011688 67.00 2.59584185e-02 -4.81378026e-01 4.82077425e-01 -1.51692328 0.36163306 67.25 -1.94338914e-02 -4.97025388e-01 4.97405179e-01 -1.60987682 0.34693043 67.50 -4.88346002e-02 -5.37814939e-01 5.40027524e-01 -1.66134987 0.38182292 67.75 2.24479629e-02 -5.20404105e-01 5.20888033e-01 -1.52768741 0.31267851 68.00 4.97117183e-02 -5.51756401e-01 5.53991319e-01 -1.48094171 0.34902208 68.25 2.06461261e-01 -5.92194316e-01 6.27152581e-01 -1.23533566 0.42283786 68.50 2.90685252e-01 -5.72248069e-01 6.41845595e-01 -1.10079251 0.32825417 68.75 5.49108345e-01 -6.56981418e-01 8.56238610e-01 -0.87460114 0.36119610 69.00 7.80385946e-01 -6.89230221e-01 1.04117267e+00 -0.72345063 0.32381508 69.25 3.15318126e-01 -1.32649859e+00 1.36346032e+00 -1.33742050 0.19881229 69.50 -9.61056420e-02 -1.43362568e+00 1.43684338e+00 -1.63773295 0.28871122 69.75 4.22042041e-01 -1.13102590e+00 1.20720299e+00 -1.21364877 0.39230029 70.00 7.60860721e-01 -1.13766317e+00 1.36864404e+00 -0.98132336 0.30559575 70.25 6.99143134e-01 -1.82572313e+00 1.95501050e+00 -1.20508245 0.30763789 70.50 1.23979190e+00 -2.20429062e+00 2.52902769e+00 -1.05844876 0.38171633 70.75 1.83525765e+00 -2.32111017e+00 2.95900711e+00 -0.90176360 0.47247384 71.00 1.61494722e+00 -2.35902060e+00 2.85885164e+00 -0.97049193 0.34603749 71.25 1.29654743e+00 -1.06992812e+00 1.68100608e+00 -0.68992692 0.11653194 71.50 -4.15173634e-01 1.56777136e-01 4.43788482e-01 2.78052852 0.01273609 71.75 -2.57934354e+00 -1.87158083e-01 2.58612475e+00 -3.06915924 0.37698854 72.00 -3.01532497e+00 -8.69032267e-01 3.13805700e+00 -2.86099161 0.50711814 72.25 -3.39271705e+00 -9.38793778e-01 3.52020777e+00 -2.87163872 0.64312137 72.50 -3.12162927e+00 -7.83778919e-01 3.21852120e+00 -2.89559771 0.62769299 72.75 -3.15772455e+00 -7.58544153e-01 3.24755501e+00 -2.90584099 0.70226179 73.00 -2.96670064e+00 -7.93486582e-01 3.07098253e+00 -2.88024571 0.65234157 73.25 -2.94495918e+00 -8.28758584e-01 3.05935048e+00 -2.86727139 0.77361227 73.50 -2.78029504e+00 -9.94636226e-01 2.95285315e+00 -2.79803492 0.71399048 73.75 -2.70703591e+00 -1.14855057e+00 2.94061419e+00 -2.74032908 0.72694883 74.00 -2.72340804e+00 -9.98912307e-01 2.90082353e+00 -2.79004126 0.65676170 74.25 -2.85767831e+00 -1.14342368e+00 3.07794461e+00 -2.76097999 0.71422341 74.50 -3.09552428e+00 -1.35384386e+00 3.37863342e+00 -2.72930370 0.72889558 74.75 -3.29279781e+00 -1.43372015e+00 3.59138844e+00 -2.73093701 0.79522368 75.00 -3.09037703e+00 -1.16022926e+00 3.30099411e+00 -2.78244250 0.71788881 75.25 -3.17585264e+00 -9.06379844e-01 3.30266020e+00 -2.86358606 0.72715313 75.50 -3.29113620e+00 -1.06442085e+00 3.45898384e+00 -2.82879004 0.65932254 75.75 -3.51620882e+00 -1.37368196e+00 3.77501346e+00 -2.76915401 0.76675245 76.00 -3.39579091e+00 -1.29673469e+00 3.63495760e+00 -2.77681672 0.75752298 76.25 -3.56098202e+00 -1.07671813e+00 3.72020361e+00 -2.84796709 0.73321918 76.50 -3.32083380e+00 -9.59336984e-01 3.45662619e+00 -2.86036462 0.71467675 76.75 -3.50384332e+00 -7.40126868e-01 3.58115984e+00 -2.93341996 0.75589044 77.00 -3.75801492e+00 -5.36895994e-01 3.79617353e+00 -2.99968602 0.71380641 77.25 -3.85131428e+00 -5.55034668e-01 3.89110334e+00 -2.99846248 0.71568390 77.50 -3.92235727e+00 -3.66143290e-01 3.93940953e+00 -3.04851462 0.68101287 77.75 -3.70226888e+00 -2.49387600e-01 3.71065884e+00 -3.07433351 0.69163163 78.00 -3.32440065e+00 -5.15760682e-01 3.36417133e+00 -2.98767577 0.61612987 78.25 -3.25331903e+00 -8.25221929e-01 3.35634860e+00 -2.89317659 0.57760000 78.50 -2.64638914e+00 -8.27524972e-01 2.77275550e+00 -2.83852590 0.37016686 78.75 -2.93613963e+00 -7.60726905e-01 3.03308776e+00 -2.88807637 0.37720521 79.00 -3.89430336e+00 -8.52640275e-01 3.98655166e+00 -2.92604837 0.47081646 79.25 -4.14796044e+00 -5.88699915e-01 4.18952783e+00 -3.00060907 0.44988576 79.50 -4.87807199e+00 -2.43292126e-01 4.88413527e+00 -3.09175930 0.52987663 79.75 -4.91653732e+00 -2.98933040e-01 4.92561673e+00 -3.08086587 0.49756773 80.00 -7.06487445e+00 -2.44106257e-01 7.06909038e+00 -3.10705429 0.57264953 80.25 -8.60545860e+00 8.03848603e-01 8.64292140e+00 3.04845146 0.52410722 80.50 -9.05370918e+00 1.09546886e+01 1.42117857e+01 2.26146975 0.54548465 80.75 -1.14670547e+00 1.12598124e+01 1.13180523e+01 1.67228697 0.49023592 81.00 2.09309310e+00 7.41542002e+00 7.70516014e+00 1.29569108 0.72230876 81.25 2.35276638e+00 5.84862888e+00 6.30412320e+00 1.18832893 0.70017296 81.50 2.62900719e+00 3.57398978e+00 4.43678732e+00 0.93657867 0.75486231 81.75 1.84648627e+00 2.40700869e+00 3.03367803e+00 0.91642246 0.79076499 82.00 9.83573680e-01 1.89277376e+00 2.13307518e+00 1.09155516 0.81084242 82.25 6.22345128e-01 1.63497425e+00 1.74941540e+00 1.20708563 0.69195304 82.50 2.27012479e-01 1.50090877e+00 1.51797951e+00 1.42068409 0.56210623 82.75 -2.57231317e-02 1.11171368e+00 1.11201124e+00 1.59393047 0.38353240 83.00 -4.58335124e-01 8.89115735e-01 1.00029889e+00 2.04676332 0.46218141 83.25 -6.75313911e-01 1.26478858e+00 1.43378486e+00 2.06122136 0.46169719 83.50 -2.66986995e-01 2.05573378e+00 2.07299866e+00 1.69994772 0.56867823 83.75 1.99995667e-01 1.94933806e+00 1.95957065e+00 1.46855734 0.61911984 84.00 1.97053103e-01 1.53269615e+00 1.54531143e+00 1.44293143 0.56279842 84.25 1.65805350e-01 1.25256959e+00 1.26349594e+00 1.43918929 0.40500706 84.50 3.89023535e-02 1.09759813e+00 1.09828733e+00 1.53536799 0.43640009 84.75 9.78649631e-02 6.98479654e-01 7.05302331e-01 1.43159113 0.21631402 85.00 7.17867154e-02 3.70061648e-01 3.76960152e-01 1.37919026 0.10754925 85.25 3.25307751e-02 3.05689368e-01 3.07415421e-01 1.46477759 0.07440587 85.50 2.55401723e-02 2.61844289e-01 2.63086929e-01 1.47356436 0.10364198 85.75 -1.88113045e-01 2.88326587e-01 3.44265506e-01 2.14887823 0.15261425 86.00 -3.12431599e-01 3.46266918e-01 4.66384265e-01 2.30487267 0.29334737 86.25 -2.94007094e-01 2.92635641e-01 4.14820190e-01 2.35853228 0.20398285 86.50 -3.03995517e-01 3.98762671e-01 5.01422918e-01 2.22215278 0.33077138 86.75 -3.10283102e-01 2.80639923e-01 4.18371091e-01 2.40631667 0.22102501 87.00 -3.09612642e-01 2.85710518e-01 4.21296200e-01 2.39632277 0.21378902 87.25 -2.36517281e-01 2.64163026e-01 3.54573728e-01 2.30103414 0.15881685 87.50 -2.39141554e-01 2.62648951e-01 3.55208606e-01 2.30938168 0.18285530 87.75 -2.39887022e-01 2.61815036e-01 3.55095616e-01 2.31251505 0.16629383 88.00 -2.26884551e-01 1.46089333e-01 2.69849389e-01 2.56952269 0.10330357 88.25 -6.13966237e-02 7.70522185e-02 9.85220268e-02 2.24359424 0.01645628 88.50 -7.80340890e-02 2.10818167e-02 8.08316895e-02 2.87773018 0.01450466 88.75 -4.37095645e-02 3.03496018e-02 5.32130092e-02 2.53467078 0.00584689 89.00 -1.02079905e-01 -3.55767647e-02 1.08101865e-01 -2.80623801 0.01302934 89.25 -4.02434571e-01 1.20144035e-01 4.19985920e-01 2.85147307 0.21075948 89.50 -3.45708904e-01 1.12711576e-01 3.63618682e-01 2.82642917 0.19078509 89.75 -3.05775825e-01 1.48830526e-01 3.40072611e-01 2.68861661 0.18438483 90.00 -2.79318945e-01 1.02403698e-01 2.97498892e-01 2.79018967 0.13750824 90.25 -1.73424095e-01 1.26652089e-01 2.14747918e-01 2.51081744 0.09603008 90.50 -1.24594752e-01 7.10757186e-02 1.43442009e-01 2.62318065 0.03644756 90.75 -8.40277037e-02 4.42094342e-02 9.49480335e-02 2.65726080 0.01883989 91.00 -9.81577584e-02 -5.32793059e-02 1.11685406e-01 -2.64429978 0.02421002 91.25 -1.88803066e-01 -7.93353207e-02 2.04794265e-01 -2.74379344 0.09853964 91.50 -2.37600764e-01 -6.99137501e-02 2.47673284e-01 -2.85542046 0.10640245 91.75 -2.43685705e-01 -4.12355801e-02 2.47149947e-01 -2.97396434 0.13536839 92.00 -1.94645576e-01 -2.04906793e-03 1.94656361e-01 -3.13106587 0.09150105 92.25 -2.00967943e-01 -7.42289092e-03 2.01104981e-01 -3.10467374 0.17839517 92.50 -1.59917559e-01 -5.16314121e-03 1.60000887e-01 -3.10931760 0.07839203 92.75 -7.36922341e-02 -1.01681697e-02 7.43904365e-02 -3.00447689 0.01615790 93.00 -5.40498948e-02 -2.04872938e-02 5.78024250e-02 -2.77928119 0.00789950 93.25 -1.90280013e-02 6.91114243e-03 2.02442269e-02 2.79319910 0.00136172 93.50 3.74814392e-03 -9.23447159e-02 9.24207505e-02 -1.53022998 0.01871956 93.75 9.77743909e-03 -3.04919894e-01 3.05076614e-01 -1.53874171 0.24874236 94.00 8.30845073e-03 -2.92814369e-01 2.92932220e-01 -1.54242947 0.19605322 94.25 -2.84456665e-03 -2.55147198e-01 2.55163054e-01 -1.58194459 0.19157089 94.50 -6.37677374e-03 -2.44169659e-01 2.44252913e-01 -1.59690655 0.14243996 94.75 2.24650269e-03 -2.54850919e-01 2.54860820e-01 -1.56198159 0.17564234 95.00 -2.02313516e-02 -1.32558583e-01 1.34093570e-01 -1.72224955 0.03933920 95.25 -1.53681500e-02 -3.72915001e-02 4.03340552e-02 -1.96169742 0.00490424 95.50 1.11122001e-01 1.18493496e-02 1.11751985e-01 0.10623226 0.03459336 95.75 1.90448799e-01 1.71653767e-02 1.91220802e-01 0.08988831 0.10923641 96.00 2.72593196e-01 -3.34794184e-02 2.74641443e-01 -0.12220623 0.18999351 96.25 3.64807763e-01 -5.83672124e-02 3.69447473e-01 -0.15864984 0.32030798 96.50 4.69972126e-01 -9.62161587e-02 4.79720073e-01 -0.20193695 0.45097896 96.75 5.40057215e-01 -1.37615301e-01 5.57314782e-01 -0.24950635 0.59153736 97.00 5.53327946e-01 -2.11326687e-01 5.92309703e-01 -0.36482317 0.57035281 97.25 5.40068004e-01 -2.81273646e-01 6.08923898e-01 -0.48015788 0.59642911 97.50 4.30511254e-01 -2.88792276e-01 5.18402275e-01 -0.59086722 0.38991813 97.75 4.65205590e-01 -2.83786713e-01 5.44932234e-01 -0.54775772 0.38589875 98.00 4.37555411e-01 -2.19823838e-01 4.89670560e-01 -0.46555846 0.29488440 98.25 4.17626785e-01 -2.02237603e-01 4.64017435e-01 -0.45097196 0.26841416 98.50 4.51813836e-01 -2.31601720e-01 5.07715569e-01 -0.47368014 0.29041287 98.75 4.02771695e-01 -2.44254506e-01 4.71047027e-01 -0.54513706 0.21542213 99.00 7.42664999e-01 -2.61316577e-01 7.87297691e-01 -0.33833383 0.47252980 99.25 7.94712446e-01 -2.32180127e-01 8.27934467e-01 -0.28424516 0.50957787 99.50 9.56749679e-01 -2.54572984e-01 9.90039066e-01 -0.26005560 0.58308373 99.75 9.79179250e-01 -2.54255482e-01 1.01165105e+00 -0.25405128 0.57534451 100.00 1.07224978e+00 -1.71407198e-01 1.08586372e+00 -0.15851634 0.62342189 100.25 1.22993209e+00 -2.22790534e-01 1.24994743e+00 -0.17919744 0.71483262 100.50 1.37640228e+00 -1.94665175e-01 1.39009991e+00 -0.14049860 0.76471223 100.75 1.40208565e+00 -2.78918098e-01 1.42955919e+00 -0.19636733 0.74889352 101.00 1.15949681e+00 -3.98140907e-01 1.22594822e+00 -0.33075966 0.69593854 101.25 1.18283947e+00 -2.70947376e-01 1.21347505e+00 -0.22518039 0.67336587 101.50 1.49260653e+00 5.97820688e-02 1.49380325e+00 0.04003073 0.79221080 101.75 1.59442397e+00 -1.29672546e-02 1.59447670e+00 -0.00813270 0.76248026 102.00 2.03308588e+00 -3.39326857e-01 2.06120860e+00 -0.16537800 0.73867641 102.25 2.12555499e+00 -3.85981359e-01 2.16031609e+00 -0.17963344 0.78327211 102.50 2.17868438e+00 -5.67441715e-01 2.25136753e+00 -0.25479097 0.82579804 102.75 2.25129510e+00 -5.48545772e-01 2.31716035e+00 -0.23900075 0.81493553 103.00 2.29810352e+00 -5.14419696e-01 2.35497504e+00 -0.22021512 0.81289874 103.25 2.57358317e+00 -8.14088616e-01 2.69927223e+00 -0.30636573 0.82773842 103.50 2.68494849e+00 -1.27830497e+00 2.97372023e+00 -0.44434576 0.86360231 103.75 2.51582270e+00 -1.40177272e+00 2.87998796e+00 -0.50834098 0.85091228 104.00 2.17531440e+00 -1.63120023e+00 2.71897167e+00 -0.64341708 0.84016269 104.25 2.07293035e+00 -1.59277078e+00 2.61418419e+00 -0.65515259 0.85152630 104.50 2.04686752e+00 -1.66867622e+00 2.64086103e+00 -0.68396125 0.88572871 104.75 1.84158423e+00 -1.56428363e+00 2.41628139e+00 -0.70415887 0.90208719 105.00 1.79377160e+00 -1.33737941e+00 2.23745396e+00 -0.64065884 0.91990491 105.25 2.01258700e+00 -1.00180606e+00 2.24813741e+00 -0.46186227 0.91247701 105.50 2.21214000e+00 -8.49025139e-01 2.36947401e+00 -0.36646562 0.92875170 105.75 2.88155369e+00 -1.17067452e+00 3.11027820e+00 -0.38589558 0.88861966 106.00 3.25748971e+00 -2.00413182e+00 3.82462855e+00 -0.55154871 0.83617361 106.25 1.18489111e+00 -2.68848228e+00 2.93801019e+00 -1.15567917 0.45501143 106.50 1.95652743e-01 -1.33054852e+00 1.34485663e+00 -1.42479595 0.25661582 106.75 1.19648150e+00 -2.84864226e-01 1.22992504e+00 -0.23373344 0.50393626 107.00 1.56242774e+00 -7.52414991e-02 1.56423838e+00 -0.04811961 0.78074593 107.25 2.02119039e+00 -1.18484178e-01 2.02466024e+00 -0.05855398 0.86671041 107.50 2.18359527e+00 -3.31133976e-02 2.18384633e+00 -0.01516346 0.90350003 107.75 2.40417352e+00 1.54953092e-01 2.40916184e+00 0.06436269 0.88694220 108.00 2.54676585e+00 2.70201141e-01 2.56105934e+00 0.10570038 0.90590864 108.25 2.53278010e+00 1.68540259e-03 2.53278066e+00 0.00066544 0.87334993 108.50 2.75963929e+00 -1.70413999e-01 2.76489601e+00 -0.06167396 0.88817522 108.75 3.00804116e+00 -9.16018682e-02 3.00943559e+00 -0.03044292 0.92288052 109.00 2.99672545e+00 -1.23447573e-01 2.99926703e+00 -0.04117088 0.92989674 109.25 2.82791836e+00 -1.96352999e-01 2.83472693e+00 -0.06932250 0.86186400 109.50 2.58646438e+00 -4.52432520e-01 2.62573669e+00 -0.17317111 0.74663177 109.75 2.19148229e+00 -2.43453234e-01 2.20496352e+00 -0.11063703 0.82999049 110.00 2.43176970e+00 -1.11458272e-01 2.43432266e+00 -0.04580217 0.89306414 110.25 2.71753386e+00 1.05949917e-01 2.71959844e+00 0.03896779 0.92096922 110.50 2.82083947e+00 1.57297868e-01 2.82522175e+00 0.05570510 0.88902879 110.75 2.87902443e+00 1.29680497e-02 2.87905364e+00 0.00450429 0.82001648 111.00 3.04752338e+00 -1.71962854e-01 3.05237120e+00 -0.05636731 0.83409506 111.25 3.46613432e+00 -4.01608267e-01 3.48932319e+00 -0.11535197 0.87457745 111.50 3.51444116e+00 -8.02054803e-01 3.60480077e+00 -0.22437420 0.88358572 111.75 3.43389165e+00 -1.30565143e+00 3.67373618e+00 -0.36334360 0.89579668 112.00 2.97519413e+00 -1.32576925e+00 3.25721418e+00 -0.41919524 0.83270521 112.25 2.72838364e+00 -1.26626939e+00 3.00790882e+00 -0.43452543 0.82766931 112.50 2.87173796e+00 -1.38497882e+00 3.18826681e+00 -0.44937055 0.83813116 112.75 3.12092022e+00 -1.63232650e+00 3.52202113e+00 -0.48189929 0.90221772 113.00 3.29782536e+00 -1.67615447e+00 3.69934398e+00 -0.47023417 0.90736490 113.25 3.64207518e+00 -1.50563019e+00 3.94101940e+00 -0.39200360 0.93490611 113.50 3.78315084e+00 -1.40772870e+00 4.03657409e+00 -0.35623003 0.92744112 113.75 4.11454817e+00 -1.24250310e+00 4.29806010e+00 -0.29327050 0.92601255 114.00 4.29652058e+00 -1.41021249e+00 4.52203365e+00 -0.31714330 0.90442046 114.25 4.56602161e+00 -1.72111759e+00 4.87963104e+00 -0.36047068 0.91314547 114.50 5.11080312e+00 -1.61952639e+00 5.36126611e+00 -0.30687288 0.88397053 114.75 5.49262149e+00 -1.22116971e+00 5.62673496e+00 -0.21877081 0.87662256 115.00 5.71971660e+00 -1.06773672e+00 5.81852384e+00 -0.18455231 0.86302521 115.25 6.31302767e+00 -8.72638511e-01 6.37305392e+00 -0.13735779 0.89660825 115.50 5.93322764e+00 -5.31775985e-01 5.95701065e+00 -0.08938792 0.85834276 115.75 5.73610201e+00 -3.15520088e-01 5.74477321e+00 -0.05495063 0.89951433 116.00 5.38825573e+00 -3.94562660e-02 5.38840019e+00 -0.00732251 0.89579326 116.25 5.07424569e+00 3.32872853e-01 5.08515228e+00 0.06550660 0.90097220 116.50 4.78814724e+00 4.58165587e-01 4.81001764e+00 0.09539700 0.87065838 116.75 4.37737990e+00 5.80510210e-01 4.41570457e+00 0.13184657 0.83959649 117.00 4.42442919e+00 1.02171865e+00 4.54086806e+00 0.22694831 0.79858760 117.25 4.26715496e+00 1.47713290e+00 4.51558779e+00 0.33325284 0.70295140 117.50 3.44786067e+00 3.00305144e+00 4.57231464e+00 0.71655421 0.62622435 117.75 3.29744698e+00 3.22581763e+00 4.61292271e+00 0.77441801 0.65405479 118.00 2.19050086e+00 2.23418623e+00 3.12887873e+00 0.79527094 0.39103309 118.25 8.89298637e-01 2.71893443e+00 2.86067414e+00 1.25468776 0.23524034 118.50 -3.67160959e-01 5.11782184e+00 5.13097531e+00 1.64241527 0.25712301 118.75 -1.11277946e-01 7.68994070e+00 7.69074578e+00 1.58526590 0.36249663 119.00 8.15291338e-01 1.08380975e+01 1.08687192e+01 1.49571316 0.46818960 119.25 1.90269145e+00 1.30630687e+01 1.32009090e+01 1.42615919 0.53868510 119.50 8.26771163e+00 1.36070957e+01 1.59219380e+01 1.02480516 0.69515936 119.75 1.01181069e+01 1.43168619e+01 1.75313611e+01 0.95557013 0.76030454 120.00 1.03539093e+01 1.31512505e+01 1.67379457e+01 0.90385070 0.76406806 120.25 1.06172797e+01 1.14809642e+01 1.56377482e+01 0.82446214 0.80647545 120.50 1.02575607e+01 1.05358811e+01 1.47045007e+01 0.79878237 0.81738441 120.75 1.10631224e+01 1.10674544e+01 1.56486812e+01 0.78559391 0.79308389 121.00 1.33218417e+01 1.13490067e+01 1.75006120e+01 0.70560172 0.83633587 121.25 1.23823667e+01 1.05963198e+01 1.62973924e+01 0.70782788 0.83822876 121.50 1.15445826e+01 9.15675557e+00 1.47351132e+01 0.67055917 0.84189948 121.75 9.25393119e+00 9.20103093e+00 1.30496825e+01 0.78253172 0.80395263 122.00 5.98980867e+00 1.00113346e+01 1.16663889e+01 1.03162577 0.65221979 122.25 3.01366107e+00 1.36685894e+01 1.39968743e+01 1.35378750 0.52864638 122.50 -1.42667542e+00 2.84781771e+01 2.85138909e+01 1.62085163 0.51928485 122.75 1.11217054e+01 2.77269807e+01 2.98743668e+01 1.18932919 0.44750972 123.00 2.94889270e+01 1.21351258e+01 3.18882124e+01 0.39039323 0.63236069 123.25 2.59739812e+01 7.25012133e+00 2.69668678e+01 0.27220191 0.69647436 123.50 1.62045865e+01 4.67174532e+00 1.68645731e+01 0.28068648 0.63570983 123.75 1.08974795e+01 7.71226379e+00 1.33504334e+01 0.61588226 0.52724047 124.00 7.35245556e-02 4.20285914e+00 4.20350220e+00 1.55330417 0.05199262 124.25 2.54104404e+00 -4.68355951e+00 5.32847393e+00 -1.07369437 0.05885701 124.50 9.01588550e+00 -8.19320427e+00 1.21825608e+01 -0.73762949 0.31428246 124.75 1.21296961e+01 -5.83964287e+00 1.34622047e+01 -0.44868445 0.52806027 125.00 1.28318727e+01 -5.17255077e+00 1.38351812e+01 -0.38317747 0.78602635 125.25 1.19934368e+01 -3.24479107e+00 1.24246205e+01 -0.26422181 0.84477300 125.50 1.15779936e+01 -1.85325723e+00 1.17253784e+01 -0.15872080 0.91570063 125.75 1.16685612e+01 -6.78355252e-01 1.16882628e+01 -0.05806993 0.92443304 126.00 1.09077761e+01 2.26745302e-01 1.09101325e+01 0.02078450 0.93920288 126.25 1.01422581e+01 9.31390406e-01 1.01849343e+01 0.09157580 0.93866503 126.50 9.51043790e+00 1.50231936e+00 9.62836396e+00 0.15667074 0.93941268 126.75 8.72609610e+00 2.61655695e+00 9.10994640e+00 0.29132307 0.89085296 127.00 8.66880185e+00 3.25429326e+00 9.25951133e+00 0.35912384 0.90901362 127.25 7.69104254e+00 3.99951229e+00 8.66880811e+00 0.47953671 0.89863833 127.50 7.55880703e+00 4.26266508e+00 8.67789590e+00 0.51347780 0.90455992 127.75 7.32460018e+00 4.08053889e+00 8.38454325e+00 0.50827835 0.90035741 128.00 7.41206319e+00 4.23145357e+00 8.53486263e+00 0.51873807 0.89364566 128.25 6.41573015e+00 4.36335570e+00 7.75889595e+00 0.59724691 0.85428504 128.50 6.00152779e+00 4.83390831e+00 7.70616671e+00 0.67805304 0.86345718 128.75 4.85078595e+00 5.57874766e+00 7.39273629e+00 0.85508325 0.82309968 129.00 4.42953808e+00 6.36530626e+00 7.75486502e+00 0.96283566 0.81740118 129.25 4.49515849e+00 6.72664226e+00 8.09037490e+00 0.98169017 0.81485445 129.50 4.10948654e+00 7.15165443e+00 8.24827501e+00 1.04924737 0.79701374 129.75 1.55923196e+00 8.41454997e+00 8.55779501e+00 1.38757268 0.76489491 130.00 6.47011686e-01 9.65006548e+00 9.67173138e+00 1.50384914 0.77152570 130.25 1.98686781e+00 1.35573783e+01 1.37021951e+01 1.42527970 0.84415074 130.50 3.64251239e+00 1.52644521e+01 1.56930365e+01 1.33654985 0.80764709 130.75 9.43622424e+00 1.84688594e+01 2.07398432e+01 1.09844601 0.87362592 131.00 1.01013677e+01 1.98595331e+01 2.22809041e+01 1.10026004 0.89949968 131.25 1.12059996e+01 2.03322713e+01 2.32158499e+01 1.06707560 0.80311185 131.50 1.57755537e+01 1.95033109e+01 2.50848008e+01 0.89067297 0.74385894 131.75 1.96646826e+01 1.50067843e+01 2.47366796e+01 0.65185390 0.69672676 132.00 2.13701108e+01 7.64851037e+00 2.26976067e+01 0.34370140 0.61521690 132.25 1.66763342e+01 -2.42111564e+00 1.68511698e+01 -0.14417538 0.69386455 132.50 1.50834066e+01 -4.31545297e-01 1.50895788e+01 -0.02860280 0.81008856 132.75 1.32201768e+01 3.14568359e+00 1.35892751e+01 0.23360162 0.81472372 133.00 1.15103180e+01 7.45779029e+00 1.37151761e+01 0.57491315 0.67210416 133.25 1.58246126e+01 1.41280776e+01 2.12136970e+01 0.72881813 0.82073449 133.50 1.90042602e+01 1.14576337e+01 2.21909728e+01 0.54254778 0.77250004 133.75 2.55228897e+01 7.23399603e+00 2.65282604e+01 0.27618807 0.84300876 134.00 2.46750316e+01 4.59944984e+00 2.51000423e+01 0.18428604 0.80046112 134.25 2.17736066e+01 -3.41737898e-01 2.17762882e+01 -0.01569376 0.77323283 134.50 2.11969943e+01 3.31130874e-01 2.11995805e+01 0.01562033 0.74725265 134.75 2.09669254e+01 1.04721997e+00 2.09930615e+01 0.04990481 0.75870321 135.00 1.90343052e+01 -3.11955956e-01 1.90368614e+01 -0.01638768 0.69535673 135.25 1.76370224e+01 7.35390604e-01 1.76523471e+01 0.04167171 0.64535723 135.50 1.69843807e+01 9.10504744e-01 1.70087685e+01 0.05355709 0.59257623 135.75 1.60989949e+01 -3.98528621e-01 1.61039270e+01 -0.02474982 0.50375200 136.00 1.33541065e+01 -2.79448364e+00 1.36433610e+01 -0.20628358 0.27397150 136.25 6.18347119e+00 -1.07020282e+01 1.23599645e+01 -1.04687157 0.16379476 136.50 -1.36770808e+01 -8.52917023e+00 1.61186006e+01 -2.58399321 0.16675082 136.75 -3.28258247e+01 -4.10600041e+00 3.30816264e+01 -3.01715450 0.34009878 137.00 -3.32443514e+01 -1.07976356e+00 3.32618820e+01 -3.10912446 0.26133412 137.25 -4.27219715e+01 2.14022642e+00 4.27755470e+01 3.09153788 0.33439090 137.50 -3.75175858e+01 2.11894512e+01 4.30878415e+01 2.62746746 0.40249934 137.75 -3.57160358e+01 1.96367480e+01 4.07582763e+01 2.63890147 0.48242713 138.00 -3.10997495e+01 1.33923184e+01 3.38607237e+01 2.73496755 0.53624795 138.25 -2.82262886e+01 1.12433417e+01 3.03831549e+01 2.76252786 0.55401088 138.50 -2.38136290e+01 3.77327511e+00 2.41107141e+01 2.98444884 0.70860405 138.75 -2.48393965e+01 -9.79430850e-01 2.48586987e+01 -3.10218253 0.83315811 139.00 -2.14157230e+01 -1.07937381e+00 2.14429065e+01 -3.09123427 0.84541502 139.25 -1.98293512e+01 -1.39333582e+00 1.98782432e+01 -3.07144162 0.84240792 139.50 -1.75265989e+01 -3.61661645e+00 1.78958538e+01 -2.93809870 0.83483926 139.75 -1.64914174e+01 -3.92432312e+00 1.69519073e+01 -2.90797600 0.81822295 140.00 -1.53418757e+01 -3.80625682e+00 1.58069840e+01 -2.89840686 0.78720052 140.25 -1.47811740e+01 -4.08850638e+00 1.53361987e+01 -2.87173743 0.74559756 140.50 -1.32556874e+01 -4.64337264e+00 1.40454319e+01 -2.80465696 0.70987162 140.75 -1.15490397e+01 -3.55588951e+00 1.20840667e+01 -2.84290873 0.66941270 141.00 -1.01157511e+01 -3.77553007e+00 1.07973630e+01 -2.78437221 0.59012936 141.25 -8.40469406e+00 -3.89164036e+00 9.26195158e+00 -2.70795451 0.47243024 141.50 -7.31393739e+00 -3.11611641e+00 7.95008564e+00 -2.73883143 0.36250918 141.75 -6.48433794e+00 -1.50421193e+00 6.65652252e+00 -2.91364819 0.27557663 142.00 -2.37084345e+00 -1.38678543e+00 2.74664751e+00 -2.61232523 0.05277977 142.25 -9.00768571e-01 -2.03894210e+00 2.22905112e+00 -1.98679545 0.03914887 142.50 2.87089163e+00 -3.68079578e+00 4.66800560e+00 -0.90839184 0.11259587 142.75 4.58641099e+00 -5.11569191e+00 6.87062366e+00 -0.83989736 0.16475485 143.00 5.11067639e+00 -1.14722758e+01 1.25591451e+01 -1.15170708 0.31874982 143.25 1.63795978e+00 -1.12981188e+01 1.14162341e+01 -1.42682309 0.21080141 143.50 -1.54913309e+00 -9.42708444e+00 9.55351947e+00 -1.73366860 0.09707491 143.75 1.24954797e-01 -8.91278927e+00 8.91366514e+00 -1.55677753 0.06532021 144.00 -5.25801700e+00 -1.09595553e+01 1.21555993e+01 -2.01812573 0.10597331 144.25 -3.73366759e+00 -7.09236306e+00 8.01510371e+00 -2.05536754 0.05136258 144.50 -3.35907075e+00 -2.47010848e+00 4.16950743e+00 -2.50753061 0.01565572 144.75 -5.50677954e+00 -2.77443249e-01 5.51376420e+00 -3.09125309 0.04239328 145.00 -1.95914669e+01 -1.73385537e+00 1.96680409e+01 -3.05332209 0.32012978 145.25 -2.13080661e+01 -1.34715235e+00 2.13506089e+01 -3.07845404 0.31706519 145.50 -2.49721157e+01 1.69054575e+00 2.50292730e+01 3.07399845 0.40865493 145.75 -2.78274387e+01 5.54084862e+00 2.83737087e+01 2.94504861 0.50685330 146.00 -2.79428892e+01 7.30054138e+00 2.88808407e+01 2.88603864 0.57290596 146.25 -2.53367039e+01 4.24199562e+00 2.56893575e+01 2.97570631 0.48007553 146.50 -2.30503795e+01 -2.57653766e+00 2.31939333e+01 -3.03027620 0.35704440 146.75 -1.65520133e+01 -6.47659079e-01 1.65646795e+01 -3.10248389 0.22659499 147.00 -1.81492359e+01 3.83715926e+00 1.85504327e+01 2.93323830 0.30920213 147.25 -1.30078774e+01 1.52528642e+00 1.30969986e+01 3.02486701 0.23340683 147.50 -9.52612721e+00 4.18529290e+00 1.04049880e+01 2.72763146 0.14979895 147.75 -1.07972787e+01 4.37438009e+00 1.16497394e+01 2.75666545 0.23538444 148.00 -1.11877004e+01 2.57422672e+00 1.14800385e+01 2.91543465 0.25072342 148.25 -1.57525149e+01 1.71824208e+00 1.58459485e+01 3.03294487 0.35457240 148.50 -1.98764154e+01 5.12830430e+00 2.05273328e+01 2.88908995 0.41492194 148.75 -1.88576690e+01 5.97049865e+00 1.97802562e+01 2.83496918 0.38491305 149.00 -1.82952598e+01 3.48541914e+00 1.86243034e+01 2.95333909 0.29275484 149.25 -1.59555296e+01 -4.52798572e+00 1.65855835e+01 -2.86507493 0.28058659 149.50 -1.27768811e+01 -4.17281385e+00 1.34410217e+01 -2.82592246 0.29402383 149.75 -9.63358008e+00 -3.39605854e+00 1.02146502e+01 -2.80267194 0.21220446 150.00 -8.45003962e+00 -3.12690365e+00 9.01003307e+00 -2.78717224 0.19286019 150.25 -5.50942459e+00 -1.97253775e-01 5.51295460e+00 -3.10580497 0.09891918 150.50 -5.56538914e+00 1.37011557e+00 5.73155939e+00 2.90020775 0.09591205 150.75 -5.42435100e-01 3.68031889e-01 6.55502333e-01 2.54545546 0.00194525 151.00 2.63186288e-01 2.79080114e-01 3.83604917e-01 0.81469977 0.00081118 151.25 5.18790492e-01 6.14756688e-01 8.04406216e-01 0.86985685 0.00515255 151.50 1.89105030e+00 6.12482818e-01 1.98776418e+00 0.31322309 0.03123402 151.75 -2.19569398e-01 1.02712815e+00 1.05033468e+00 1.78139673 0.00947244 152.00 4.33614944e-01 1.18552466e+00 1.26233539e+00 1.22015289 0.01337770 152.25 4.24504897e-01 7.93510385e-02 4.31857609e-01 0.18479347 0.00165709 152.50 2.93287799e-01 3.33273824e-01 4.43947266e-01 0.84912992 0.00173323 152.75 1.38648967e+00 2.33342041e-01 1.40598795e+00 0.16673452 0.01691609 153.00 3.01284018e+00 2.36727027e-01 3.02212601e+00 0.07841162 0.10389717 153.25 2.27689455e+00 2.88506679e-01 2.29510019e+00 0.12603892 0.06103280 153.50 1.47037051e+00 6.12555510e-01 1.59286336e+00 0.39473382 0.03181335 153.75 1.57844575e+00 1.05087720e+00 1.89626841e+00 0.58737955 0.04090716 154.00 4.72477006e-01 9.28300554e-01 1.04162202e+00 1.09999860 0.01563126 154.25 2.92590355e-01 -8.03794220e-01 8.55391293e-01 -1.22169402 0.01113983 154.50 -6.51810354e-01 -5.95913865e-01 8.83159144e-01 -2.40096331 0.01147042 154.75 -8.14752460e-01 3.58674429e-01 8.90207233e-01 2.72689726 0.01080496 155.00 -2.42088516e+00 -6.17999055e-02 2.42167384e+00 -3.11607038 0.05612323 155.25 -3.75047933e+00 -4.24557034e-01 3.77443292e+00 -3.02887176 0.10855494 155.50 -2.67630238e+00 4.12069972e-02 2.67661960e+00 3.12619688 0.06946750 155.75 -2.51690281e+00 -7.04940806e-01 2.61375999e+00 -2.86850731 0.06439095 156.00 -2.17156719e+00 -4.88012856e-01 2.22572699e+00 -2.92053672 0.06346763 156.25 -1.68508529e+00 2.94302592e-01 1.71059242e+00 2.96868520 0.03612735 156.50 -3.81122370e-01 9.70108189e-01 1.04228794e+00 1.94513748 0.01810172 156.75 2.15199710e-01 1.41913632e+00 1.43536017e+00 1.42030156 0.03600363 157.00 -2.31445780e-01 1.65833053e+00 1.67440357e+00 1.70946613 0.03357349 157.25 8.81783231e-02 2.39018779e+00 2.39181377e+00 1.53392125 0.07116789 157.50 3.75261584e-02 1.45534865e+00 1.45583238e+00 1.54501704 0.02527776 157.75 -2.10175501e-01 6.59404098e-01 6.92089233e-01 1.87935182 0.00566590 158.00 2.72569293e-01 7.52383847e-01 8.00234636e-01 1.22322889 0.01007720 158.25 4.36175668e-01 1.35359272e+00 1.42213307e+00 1.25906683 0.03434174 158.50 1.58165112e+00 2.04669310e+00 2.58661418e+00 0.91287238 0.09648381 158.75 2.64042546e+00 2.26258238e+00 3.47722959e+00 0.70848665 0.14027643 159.00 2.15485130e+00 3.87986252e+00 4.43809839e+00 1.06382149 0.17823855 159.25 1.70731676e+00 4.24877451e+00 4.57897536e+00 1.18870694 0.18697690 159.50 3.21470085e+00 3.35651799e+00 4.64763537e+00 0.80697637 0.16194537 159.75 4.11698805e+00 3.94459699e+00 5.70170465e+00 0.76401716 0.20455044 160.00 5.09433313e+00 4.08890221e+00 6.53233123e+00 0.67634704 0.23150389 160.25 5.83512030e+00 4.17207764e+00 7.17320436e+00 0.62071851 0.30238427 160.50 4.88671398e+00 5.71934617e+00 7.52269195e+00 0.86374280 0.37263347 160.75 5.25283555e+00 5.51635487e+00 7.61724703e+00 0.80986302 0.40644020 161.00 4.76127877e+00 4.38766401e+00 6.47467150e+00 0.74458391 0.49825172 161.25 4.22444545e+00 4.54067979e+00 6.20191199e+00 0.82146122 0.52826560 161.50 2.82904379e+00 4.61428262e+00 5.41249415e+00 1.02079584 0.53394312 161.75 2.27861484e+00 4.25040034e+00 4.82265370e+00 1.07869202 0.49504136 162.00 1.29794884e+00 3.77035147e+00 3.98750817e+00 1.23925189 0.50852438 162.25 1.16486614e-01 3.68192552e+00 3.68376772e+00 1.53916946 0.47017015 162.50 -2.40544356e+00 3.69134120e+00 4.40592312e+00 2.14832700 0.67353106 162.75 -2.59990111e+00 3.45002381e+00 4.31997107e+00 2.21659065 0.60695524 163.00 -2.41356258e+00 2.87026368e+00 3.75015972e+00 2.26997499 0.35145640 163.25 -2.24981679e+00 3.06048915e+00 3.79845619e+00 2.20470390 0.27143348 163.50 -1.90663066e+00 4.59695120e+00 4.97666563e+00 1.96396158 0.37458947 163.75 -3.13246187e-01 5.53002881e+00 5.53889355e+00 1.62738044 0.48608056 164.00 7.26797087e-01 5.68466769e+00 5.73094065e+00 1.44363404 0.67646423 164.25 3.56941395e-01 4.86061878e+00 4.87370722e+00 1.49749253 0.61602897 164.50 -8.39372808e-01 4.01503292e+00 4.10183325e+00 1.77688567 0.56014451 164.75 -1.65437077e+00 4.24969486e+00 4.56035624e+00 1.94203743 0.57122401 165.00 -2.16895099e+00 4.36297959e+00 4.87236485e+00 2.03214217 0.51598721 165.25 -1.65104760e+00 3.51414495e+00 3.88267600e+00 2.01001724 0.37156332 165.50 -1.63523687e+00 3.26109200e+00 3.64811193e+00 2.03559402 0.40947335 165.75 -7.99614288e-01 2.55988724e+00 2.68186609e+00 1.87355646 0.22481744 166.00 7.97062528e-02 2.43222893e+00 2.43353460e+00 1.53803718 0.17401692 166.25 6.20714703e-01 2.93230937e+00 2.99728627e+00 1.36219451 0.29862189 166.50 1.78370717e-01 3.34335417e+00 3.34810890e+00 1.51749603 0.41399892 166.75 8.62950744e-02 3.03411143e+00 3.03533837e+00 1.54236236 0.39312483 167.00 4.58193703e-01 2.96202846e+00 2.99725776e+00 1.41732359 0.50499011 167.25 1.63630274e-01 2.85140208e+00 2.85609325e+00 1.51347330 0.57156560 167.50 4.27831720e-02 2.53796529e+00 2.53832586e+00 1.55394065 0.60191211 167.75 -5.97796362e-01 2.27252524e+00 2.34983647e+00 1.82802267 0.55732790 168.00 -7.54937091e-01 2.26029915e+00 2.38304055e+00 1.89314564 0.64363202 168.25 -8.27913340e-01 1.83638891e+00 2.01438941e+00 1.99434666 0.53722960 168.50 -9.57302961e-01 1.53507755e+00 1.80911361e+00 2.12840168 0.51870635 168.75 -1.23500810e+00 1.22275492e+00 1.73792249e+00 2.36117995 0.42253760 169.00 -1.45305559e+00 1.37643297e+00 2.00148402e+00 2.38326790 0.47986962 169.25 -1.17679731e+00 1.24907470e+00 1.71611175e+00 2.32640890 0.43192301 169.50 -9.82725062e-01 1.11478647e+00 1.48610142e+00 2.29331649 0.44225331 169.75 -1.27209441e+00 8.53123820e-01 1.53168027e+00 2.55084084 0.47805390 170.00 -1.35206481e+00 6.97296477e-01 1.52128289e+00 2.66544266 0.51439096 170.25 -1.98900336e+00 6.84935516e-01 2.10363281e+00 2.80995010 0.64757077 170.50 -2.10123048e+00 5.43149510e-01 2.17029513e+00 2.88863841 0.68671273 170.75 -2.69905612e+00 4.65997915e-01 2.73898850e+00 2.97062595 0.70425658 171.00 -3.04562634e+00 3.34654639e-01 3.06395717e+00 3.03215130 0.75072060 171.25 -3.78532747e+00 4.91378645e-01 3.81708751e+00 3.01250312 0.76897950 171.50 -3.88792802e+00 9.59825008e-01 4.00465333e+00 2.89955907 0.75833684 171.75 -3.83736570e+00 1.41654433e+00 4.09047349e+00 2.78796500 0.67132317 172.00 -4.19442223e+00 1.96530896e+00 4.63202085e+00 2.70341765 0.62702557 172.25 -3.02305737e+00 4.52470192e+00 5.44167284e+00 2.15980648 0.54857703 172.50 -2.01988970e+00 5.63852444e+00 5.98939999e+00 1.91478427 0.57934239 172.75 -1.28942239e-01 4.34625614e+00 4.34816841e+00 1.60045505 0.41560672 173.00 2.37580987e-01 3.13173278e+00 3.14073159e+00 1.49507889 0.39333900 173.25 1.22164326e-01 1.97419875e+00 1.97797493e+00 1.50899467 0.43376169 173.50 7.32300635e-02 1.57755490e+00 1.57925365e+00 1.52440965 0.38939930 173.75 -7.42355668e-02 1.10114281e+00 1.10364233e+00 1.63811131 0.34815833 174.00 -2.41814648e-01 1.16202515e+00 1.18691903e+00 1.77596578 0.35372353 174.25 -3.97747916e-01 1.25991129e+00 1.32120395e+00 1.87658945 0.47010165 174.50 -2.76037336e-01 1.06966981e+00 1.10471268e+00 1.82334492 0.34045378 174.75 -8.26717461e-02 5.14754604e-01 5.21351053e-01 1.73004064 0.08555157 175.00 -2.37835993e-01 5.24789791e-01 5.76168625e-01 1.99631018 0.08116912 175.25 -3.73826323e-01 4.27640891e-01 5.67998989e-01 2.28915006 0.09521799 175.50 -3.27358642e-01 1.32766958e-01 3.53257337e-01 2.75629350 0.02280321 175.75 -9.46599081e-01 7.10848745e-02 9.49264389e-01 3.06663832 0.08877082 176.00 -1.11999819e+00 9.37401310e-01 1.46051948e+00 2.44471386 0.23127200 176.25 -1.03263484e+00 1.03839419e+00 1.46444433e+00 2.35341359 0.42280286 176.50 -8.95191130e-01 6.31058127e-01 1.09526322e+00 2.52755738 0.27087809 176.75 -7.75162905e-01 2.61038054e-01 8.17935446e-01 2.81676800 0.20171046 177.00 -8.18173333e-01 3.94395156e-01 9.08270412e-01 2.69241314 0.21317218 177.25 -6.80177997e-01 5.44570976e-01 8.71320638e-01 2.46646762 0.22356339 177.50 -9.62296729e-01 5.43201929e-02 9.63828656e-01 3.08520401 0.23582079 177.75 -1.05019810e+00 -3.24061079e-02 1.05069796e+00 -3.11074530 0.35420659 178.00 -1.22299764e+00 9.10981336e-04 1.22299798e+00 3.14084778 0.38276308 178.25 -1.38840248e+00 2.32600951e-02 1.38859731e+00 3.12484108 0.51054795 178.50 -1.22759541e+00 -3.08906444e-01 1.26586480e+00 -2.89507540 0.38772039 178.75 -1.14536698e+00 -4.21740815e-01 1.22054530e+00 -2.78878408 0.43013204 179.00 -1.25795972e+00 -2.01527604e-01 1.27400002e+00 -2.98274049 0.45795115 179.25 -1.19058435e+00 -2.83752645e-01 1.22393082e+00 -2.90762678 0.52479136 179.50 -1.28344415e+00 -5.66255682e-01 1.40280946e+00 -2.72608078 0.49267549 179.75 -1.33721214e+00 -5.50146164e-01 1.44595889e+00 -2.75128655 0.51309544 180.00 -1.22380073e+00 -4.18958110e-01 1.29352779e+00 -2.81175653 0.42473372 180.25 -1.31748181e+00 -3.95020118e-01 1.37542692e+00 -2.85029215 0.48569501 180.50 -1.31043586e+00 -5.24494385e-01 1.41150151e+00 -2.76087576 0.44772597 180.75 -1.41495864e+00 -6.59620145e-01 1.56115556e+00 -2.70536826 0.48114634 181.00 -1.27447991e+00 -1.24112742e+00 1.77895934e+00 -2.36945194 0.46153582 181.25 -1.25439383e+00 -1.26003270e+00 1.77797252e+00 -2.35395189 0.46645624 181.50 -1.56346680e+00 -1.48543473e+00 2.15660492e+00 -2.38178241 0.42788327 181.75 -1.59560569e+00 -1.64643893e+00 2.29275352e+00 -2.34051640 0.43569877 182.00 -2.04737356e+00 -1.29100854e+00 2.42042177e+00 -2.57899930 0.46401776 182.25 -1.82159515e+00 -1.35227326e+00 2.26866742e+00 -2.50300127 0.43250178 182.50 -1.60655195e+00 -1.73369549e+00 2.36362206e+00 -2.31814875 0.36421654 182.75 -1.24040928e+00 -1.89823935e+00 2.26758193e+00 -2.14959479 0.28188873 183.00 -1.43615342e+00 -1.94424745e+00 2.41715428e+00 -2.20700544 0.28754677 183.25 -1.65054256e+00 -1.46055447e+00 2.20397598e+00 -2.41718662 0.19711048 183.50 -9.40311577e-01 -1.47887004e+00 1.75249606e+00 -2.13714642 0.08620179 183.75 -2.09013275e-01 -1.42694270e+00 1.44216921e+00 -1.71623834 0.06297687 184.00 1.10008924e-01 -1.86384360e+00 1.86708729e+00 -1.51184211 0.13288097 184.25 3.00273893e-01 -1.48038021e+00 1.51052639e+00 -1.37067567 0.09071590 184.50 6.40508019e-01 -2.61505894e-01 6.91835135e-01 -0.38762290 0.03299745 184.75 6.08174134e-01 5.79101322e-02 6.10925004e-01 0.09493343 0.03422250 185.00 7.19996179e-01 9.75561312e-01 1.21248273e+00 0.93499837 0.16838200 185.25 1.89527413e-01 1.32160630e+00 1.33512690e+00 1.42836059 0.22773596 185.50 1.10050129e-01 1.81100584e+00 1.81434649e+00 1.51010355 0.56266433 185.75 -1.92805480e-01 1.92213173e+00 1.93177751e+00 1.67077007 0.56092768 186.00 -4.36381828e-01 2.36002515e+00 2.40003079e+00 1.75363680 0.69987720 186.25 -2.95218946e-01 2.24997483e+00 2.26926000e+00 1.70126093 0.70163257 186.50 -1.97944693e-01 2.08002008e+00 2.08941753e+00 1.66567540 0.76664077 186.75 -3.27736530e-01 1.88477399e+00 1.91305626e+00 1.74296126 0.74097752 187.00 -4.56839056e-01 1.65208522e+00 1.71408503e+00 1.84057762 0.75108678 187.25 -3.18976657e-01 1.44207691e+00 1.47693328e+00 1.78848383 0.59210885 187.50 -3.80648201e-01 1.29498359e+00 1.34976870e+00 1.85668477 0.63447883 187.75 -6.73943879e-01 1.30962890e+00 1.47286395e+00 2.04606094 0.58093462 188.00 -8.49004738e-01 1.47445051e+00 1.70141511e+00 2.09323984 0.71313497 188.25 -1.02528963e+00 1.37221039e+00 1.71294488e+00 2.21249088 0.55829430 188.50 -1.48316666e+00 1.53937157e+00 2.13762676e+00 2.33760136 0.60362148 188.75 -1.34800806e+00 1.80201512e+00 2.25041868e+00 2.21305206 0.46279709 189.00 -1.14379517e+00 2.12918946e+00 2.41696404e+00 2.06375723 0.49920045 189.25 -5.83900133e-01 2.52273850e+00 2.58943022e+00 1.79824606 0.55260590 189.50 -4.63594041e-01 2.54020327e+00 2.58216035e+00 1.75131239 0.61267245 189.75 2.56605914e-01 2.18237661e+00 2.19741081e+00 1.45375279 0.50906908 190.00 4.23565413e-01 2.04648201e+00 2.08985556e+00 1.36670556 0.61616842 190.25 3.38610838e-01 1.63681060e+00 1.67146829e+00 1.36680157 0.48985774 190.50 3.76167396e-01 1.46352051e+00 1.51109040e+00 1.31921304 0.50150144 190.75 1.27047652e-01 1.56121934e+00 1.56638020e+00 1.48959805 0.48577453 191.00 1.52035848e-01 1.42045244e+00 1.42856573e+00 1.46416888 0.47838457 191.25 1.60516092e-01 1.11269247e+00 1.12421081e+00 1.42752556 0.41691895 191.50 1.94109806e-01 1.13113290e+00 1.14766731e+00 1.40084517 0.44313068 191.75 2.37995471e-01 1.14487057e+00 1.16934617e+00 1.36583564 0.42253558 192.00 2.45920403e-01 9.71415753e-01 1.00206058e+00 1.32284887 0.36043610 192.25 6.00644678e-01 1.01768290e+00 1.18171592e+00 1.03760787 0.45044336 192.50 5.75964761e-01 8.24678495e-01 1.00589762e+00 0.96113742 0.38590859 192.75 3.35319571e-01 5.65107163e-01 6.57103737e-01 1.03526356 0.20863414 193.00 2.93294486e-01 4.41765111e-01 5.30262265e-01 0.98470114 0.14478795 193.25 5.18576096e-01 3.47883011e-01 6.24454767e-01 0.59088816 0.17717564 193.50 4.90020514e-01 1.35618053e-01 5.08441108e-01 0.27000168 0.11635200 193.75 5.01356633e-01 9.39963880e-03 5.01444740e-01 0.01874621 0.13543027 194.00 4.02242261e-01 -1.34977717e-01 4.24285070e-01 -0.32375613 0.08059903 194.25 1.24123402e-01 -6.36073899e-01 6.48071465e-01 -1.37807827 0.20438115 194.50 1.40774937e-01 -7.57294039e-01 7.70267385e-01 -1.38700217 0.20826152 194.75 -1.73818941e-01 -9.34515913e-01 9.50543537e-01 -1.75469377 0.26988402 195.00 -2.95443653e-01 -1.00849934e+00 1.05088433e+00 -1.85577619 0.30685127 195.25 -8.72378959e-01 -1.17766273e+00 1.46558335e+00 -2.20836497 0.52930010 195.50 -1.03937144e+00 -1.22464033e+00 1.60624933e+00 -2.27454430 0.50130628 195.75 -1.40507753e+00 -1.35627414e+00 1.95287542e+00 -2.37386638 0.57506901 196.00 -1.72298779e+00 -1.17711190e+00 2.08669100e+00 -2.54224427 0.48855930 196.25 -1.99475126e+00 -8.78058707e-01 2.17945399e+00 -2.72693116 0.46523606 196.50 -1.72094583e+00 -1.22749883e-01 1.72531797e+00 -3.07038626 0.46748654 196.75 -1.54470456e+00 -2.31314934e-01 1.56192790e+00 -2.99295011 0.72454192 197.00 -1.48061224e+00 -4.18311465e-01 1.53856982e+00 -2.86624312 0.60638500 197.25 -1.11031706e+00 -5.99915473e-01 1.26202320e+00 -2.64621937 0.30914912 197.50 -1.03315287e+00 -1.83309745e-01 1.04928895e+00 -2.96599258 0.27727381 197.75 -1.24469662e+00 -6.52538360e-02 1.24640592e+00 -3.08921511 0.62730386 198.00 -1.57191676e+00 -1.38397927e-01 1.57799755e+00 -3.05377504 0.75489962 198.25 -1.75707236e+00 -2.94283231e-01 1.78154593e+00 -2.97564788 0.86958312 198.50 -1.93827714e+00 -4.04505539e-01 1.98003611e+00 -2.93585225 0.82790267 198.75 -2.14245206e+00 -4.64725468e-01 2.19227521e+00 -2.92798884 0.86037140 199.00 -2.51916229e+00 -4.98358099e-01 2.56798354e+00 -2.94628747 0.83938939 199.25 -2.88398480e+00 -3.40549560e-01 2.90402175e+00 -3.02405395 0.86558270 199.50 -3.09592884e+00 2.23922488e-01 3.10401621e+00 3.06939034 0.83992984 199.75 -3.00739169e+00 4.43321626e-01 3.03989126e+00 2.99523601 0.88761883 200.00 -3.00178907e+00 5.54414270e-01 3.05255840e+00 2.95895618 0.85396420 200.25 -3.40665946e+00 6.24507501e-01 3.46342869e+00 2.96028615 0.86576567 200.50 -3.71137084e+00 6.22428168e-01 3.76320214e+00 2.97543054 0.78655224 200.75 -3.83758197e+00 1.13410315e+00 4.00165283e+00 2.85424599 0.75456394 201.00 -3.62432539e+00 2.05787595e+00 4.16780373e+00 2.62518954 0.71746571 201.25 -3.21023597e+00 2.70546820e+00 4.19823453e+00 2.44131505 0.72809903 201.50 -2.61941635e+00 3.02072534e+00 3.99826507e+00 2.28516191 0.69365086 201.75 -2.22048106e+00 3.13453534e+00 3.84133414e+00 2.18713261 0.68154896 202.00 -1.57533853e+00 2.98651299e+00 3.37652947e+00 2.05618880 0.59347671 202.25 -1.43518468e+00 3.05002037e+00 3.37081286e+00 2.01060696 0.60765672 202.50 -1.06509679e+00 2.92900918e+00 3.11665301e+00 1.91956810 0.58546086 202.75 -9.23307755e-01 2.48833854e+00 2.65411490e+00 1.92610294 0.50038171 203.00 -6.53276458e-01 1.67244618e+00 1.79550727e+00 1.94318293 0.25856710 203.25 -7.96164330e-01 1.95082257e+00 2.10703259e+00 1.95828068 0.34202825 203.50 -8.57484583e-01 2.07157722e+00 2.24203300e+00 1.96325196 0.34838652 203.75 -7.02640766e-01 2.27262163e+00 2.37876294e+00 1.87065035 0.34623147 204.00 -3.73539312e-01 2.10782073e+00 2.14066341e+00 1.74619122 0.25047960 204.25 -5.27126259e-01 1.88500564e+00 1.95732173e+00 1.84347278 0.19822421 204.50 1.11318575e-01 1.42609931e+00 1.43043737e+00 1.49289621 0.11292804 204.75 5.91933023e-01 1.23128150e+00 1.36617672e+00 1.12267064 0.09552619 205.00 9.51395606e-01 1.27537273e+00 1.59114085e+00 0.92987648 0.13487660 205.25 2.14157967e-01 5.97331333e-01 6.34561547e-01 1.22654750 0.02114270 205.50 -4.01575072e-01 -1.73544001e-01 4.37470066e-01 -2.73367452 0.01154908 205.75 -9.83327287e-01 3.64416449e-01 1.04868103e+00 2.78668924 0.05574870 206.00 -1.53835825e+00 1.46758732e+00 2.12611351e+00 2.37973379 0.20236578 206.25 -1.19567537e+00 1.74030146e+00 2.11146602e+00 2.17277853 0.19131869 206.50 -1.20183561e+00 1.71384441e+00 2.09324425e+00 2.18236159 0.21370532 206.75 -1.14704301e+00 1.98687147e+00 2.29420268e+00 2.09436575 0.22982127 207.00 -1.12373491e+00 2.19820734e+00 2.46878425e+00 2.04336782 0.30241458 207.25 -8.28550967e-01 2.14259233e+00 2.29721540e+00 1.93978914 0.24828875 207.50 -8.60741789e-01 2.12015066e+00 2.28821224e+00 1.95644845 0.24265144 207.75 -5.10468906e-01 2.30799485e+00 2.36377214e+00 1.78846634 0.18111612 208.00 4.39517984e-01 2.05368694e+00 2.10019192e+00 1.35996269 0.14621789 208.25 6.15796123e-01 1.65942396e+00 1.76999795e+00 1.21545774 0.12545340 208.50 5.30452738e-01 1.74469277e+00 1.82354955e+00 1.27563916 0.17346000 208.75 2.20766014e-01 1.62149295e+00 1.63645257e+00 1.43547851 0.11606844 209.00 1.72354348e-01 9.64433709e-01 9.79713428e-01 1.39395278 0.06504152 209.25 -2.05794931e-01 1.22317323e+00 1.24036459e+00 1.73748200 0.08016308 209.50 -2.65238273e-01 1.52642484e+00 1.54929794e+00 1.74284284 0.14292355 209.75 -6.46644225e-01 1.91438138e+00 2.02064466e+00 1.89654563 0.16162934 210.00 -1.10341243e+00 2.80896317e+00 3.01791204e+00 1.94509638 0.23497044 210.25 -1.86057030e+00 5.51357560e-01 1.94054554e+00 2.85349893 0.06034069 210.50 -1.11732831e+00 -1.69498342e+00 2.03012102e+00 -2.15360991 0.06197523 210.75 -1.43185935e+00 -1.90865014e+00 2.38603574e+00 -2.21442208 0.11781702 211.00 -1.85118630e+00 -2.28839646e+00 2.94340773e+00 -2.25096764 0.23979995 211.25 -2.58131598e+00 -9.51370786e-01 2.75105408e+00 -2.78847960 0.26027246 211.50 -2.53589324e+00 -2.28426874e-01 2.54616051e+00 -3.05175762 0.25965903 211.75 -2.20064610e+00 8.61491081e-01 2.36326261e+00 2.76845965 0.26943343 212.00 -1.93433349e+00 1.05394095e+00 2.20282491e+00 2.64270426 0.26757119 212.25 -1.72311114e+00 1.28523136e+00 2.14963523e+00 2.50073460 0.29116460 212.50 -1.51486417e+00 1.17120942e+00 1.91482244e+00 2.48344265 0.24975800 212.75 -1.11940843e+00 1.30928252e+00 1.72258409e+00 2.27817358 0.20740820 213.00 -1.16061679e+00 1.62727124e+00 1.99876038e+00 2.19034565 0.28535361 213.25 -6.64176124e-01 1.13618624e+00 1.31607337e+00 2.09979017 0.14476245 213.50 -5.17791314e-01 1.57848590e+00 1.66124218e+00 1.88776665 0.21189409 213.75 -6.27253659e-01 1.01308919e+00 1.19155229e+00 2.12517747 0.21696609 214.00 -8.59133713e-01 1.03088888e+00 1.34195478e+00 2.26556875 0.31009138 214.25 -8.76972496e-01 1.70020194e+00 1.91305185e+00 2.04700777 0.42237007 214.50 -7.71495983e-01 2.15955432e+00 2.29322500e+00 1.91391332 0.44621234 214.75 -7.40947855e-01 2.81256981e+00 2.90853102e+00 1.82838534 0.57282737 215.00 -5.03206575e-01 2.82713494e+00 2.87156905e+00 1.74694332 0.50912385 215.25 -2.05560168e-01 2.76740449e+00 2.77502840e+00 1.64493922 0.32822616 215.50 -2.37387128e-01 2.54561455e+00 2.55665917e+00 1.66378078 0.19655584 215.75 4.90538665e-01 1.22038632e+00 1.31528361e+00 1.18860696 0.03559514 216.00 4.51905941e-01 5.04308457e-01 6.77160247e-01 0.84014546 0.00904456 216.25 -6.31561761e-01 -9.93889717e-01 1.17757676e+00 -2.13687107 0.03139409 216.50 -8.82283158e-01 -3.60785676e-01 9.53199808e-01 -2.75341797 0.03249814 216.75 -1.43591065e+00 -5.27149971e-01 1.52961645e+00 -2.78974926 0.17005278 217.00 -1.30757465e+00 -3.32591084e-01 1.34921025e+00 -2.89251728 0.16729464 217.25 -1.21577857e+00 -4.46409386e-01 1.29514434e+00 -2.78969557 0.25739724 217.50 -1.58728326e+00 -7.24742163e-01 1.74491242e+00 -2.71326967 0.39409231 217.75 -1.75480678e+00 -8.06742748e-01 1.93136757e+00 -2.71067423 0.59635606 218.00 -1.86637946e+00 -2.68294873e-01 1.88556475e+00 -2.99881923 0.46723483 218.25 -1.85384292e+00 2.51761671e-01 1.87086010e+00 3.00661314 0.46672943 218.50 -1.53279185e+00 6.41639223e-01 1.66167137e+00 2.74514836 0.35620463 218.75 -1.30831789e+00 6.07341831e-01 1.44241457e+00 2.70697996 0.38934188 219.00 -1.54236116e+00 6.03767467e-01 1.65632518e+00 2.76847290 0.37942129 219.25 -1.52697325e+00 1.00051316e+00 1.82556126e+00 2.56155212 0.48563715 219.50 -1.40819872e+00 1.07097979e+00 1.76918664e+00 2.49138525 0.35870266 219.75 -1.22424253e+00 9.91234272e-01 1.57521908e+00 2.46098222 0.26106871 220.00 -7.11582699e-01 1.02014087e+00 1.24379955e+00 2.17986518 0.18130137 220.25 -4.41958041e-01 9.31066742e-01 1.03063679e+00 2.01398291 0.15866215 220.50 -1.24081606e+00 1.11479950e+00 1.66805348e+00 2.40963978 0.28716781 220.75 -1.56504447e+00 1.39497777e+00 2.09650356e+00 2.41358593 0.48559371 221.00 -1.15348706e+00 1.74276191e+00 2.08991662e+00 2.15547290 0.39015723 221.25 -1.11017391e+00 2.02480335e+00 2.30918053e+00 2.07232364 0.47131631 221.50 -8.36033862e-01 1.69809115e+00 1.89274039e+00 2.02829512 0.34592092 221.75 -7.03837515e-01 1.94674674e+00 2.07007491e+00 1.91771941 0.44164775 222.00 -1.61449604e-01 2.40023510e+00 2.40565885e+00 1.63795924 0.51308147 222.25 2.96197906e-01 2.63737148e+00 2.65395206e+00 1.45895697 0.58549652 222.50 9.47920291e-01 3.06770158e+00 3.21081701e+00 1.27110309 0.64524287 222.75 1.32190016e+00 2.87300511e+00 3.16252722e+00 1.13956629 0.65074954 223.00 1.87426915e+00 1.45118188e+00 2.37040370e+00 0.65885100 0.42537996 223.25 1.95002292e+00 6.01425169e-01 2.04066206e+00 0.29916313 0.34071885 223.50 1.15237514e+00 -2.08006885e-02 1.15256286e+00 -0.01804832 0.12344870 223.75 3.86327573e-01 1.70948763e-01 4.22460025e-01 0.41659688 0.02164518 224.00 -2.96770072e-01 4.22723026e-01 5.16495142e-01 2.18289264 0.03125170 224.25 -6.27334084e-01 7.68303355e-01 9.91886132e-01 2.25552882 0.09529378 224.50 -3.13880751e-02 1.57071667e+00 1.57103026e+00 1.59077695 0.25789672 224.75 4.17907445e-01 1.65803249e+00 1.70988841e+00 1.32388898 0.26389644 225.00 1.04163964e+00 1.58286371e+00 1.89485373e+00 0.98876691 0.34332325 225.25 8.58226841e-01 1.41649154e+00 1.65620095e+00 1.02606299 0.25559716 225.50 1.22474610e+00 1.78911818e+00 2.16816671e+00 0.97051293 0.38189301 225.75 1.07572744e+00 1.70750059e+00 2.01810500e+00 1.00860871 0.36989974 226.00 8.18380475e-01 1.58536071e+00 1.78412869e+00 1.09426426 0.42350016 226.25 9.62135314e-01 1.84866837e+00 2.08405353e+00 1.09092464 0.48283729 226.50 1.20870406e+00 2.51345482e+00 2.78898200e+00 1.12255043 0.62892808 226.75 1.80346927e+00 2.43743109e+00 3.03209032e+00 0.93378690 0.60044423 227.00 3.20694154e+00 2.37334811e+00 3.98964350e+00 0.63711292 0.72685214 227.25 3.54084901e+00 2.18513835e+00 4.16082219e+00 0.55291468 0.66710275 227.50 3.60004905e+00 2.04313222e+00 4.13941330e+00 0.51620150 0.71587016 227.75 4.26829196e+00 1.56713657e+00 4.54689271e+00 0.35187763 0.61159577 228.00 5.40096026e+00 5.27251668e-01 5.42663488e+00 0.09731349 0.67760125 228.25 4.78402420e+00 -4.89479089e-01 4.80899962e+00 -0.10196054 0.58821141 228.50 4.63504874e+00 -1.69286480e+00 4.93451801e+00 -0.35017893 0.70673623 228.75 3.93461586e+00 -2.31315234e+00 4.56419496e+00 -0.53147336 0.63934425 229.00 3.38897713e+00 -3.11725443e+00 4.60461086e+00 -0.74365897 0.70228609 229.25 2.77035717e+00 -2.91470170e+00 4.02123921e+00 -0.81078286 0.64874056 229.50 2.70051293e+00 -2.79536074e+00 3.88674823e+00 -0.80265445 0.68767314 229.75 2.55670800e+00 -2.99649131e+00 3.93899936e+00 -0.86442780 0.62411434 230.00 2.45226001e+00 -3.57075420e+00 4.33172768e+00 -0.96900996 0.71142939 230.25 1.61089797e+00 -3.35951538e+00 3.72576648e+00 -1.12368030 0.56647334 230.50 9.18680370e-01 -3.12044142e+00 3.25286463e+00 -1.28447842 0.54844958 230.75 8.31015382e-01 -3.35470725e+00 3.45610291e+00 -1.32796826 0.53219221 231.00 6.29475208e-01 -3.63917596e+00 3.69321549e+00 -1.39951916 0.57736908 231.25 -3.03075759e-01 -2.97065717e+00 2.98607752e+00 -1.67246768 0.39131492 231.50 -3.99863076e-01 -3.08309979e+00 3.10892181e+00 -1.69977153 0.46556965 231.75 -3.71180207e-01 -2.44997535e+00 2.47793340e+00 -1.72115651 0.36900986 232.00 -2.29331835e-01 -2.35577237e+00 2.36690865e+00 -1.66783944 0.40664790 232.25 -1.78435404e-01 -2.09272436e+00 2.10031770e+00 -1.65585524 0.29260647 232.50 1.18066232e-01 -2.10449649e+00 2.10780576e+00 -1.51475318 0.28511282 232.75 -1.12851975e-01 -1.88003871e+00 1.88342271e+00 -1.63075080 0.26334159 233.00 -3.83387372e-01 -2.09471623e+00 2.12951214e+00 -1.75181867 0.34684911 233.25 -6.96538773e-01 -2.11931040e+00 2.23083904e+00 -1.88833765 0.28919222 233.50 -7.08551513e-01 -1.84584643e+00 1.97716825e+00 -1.93731427 0.28727037 233.75 -8.52733838e-01 -2.16322449e+00 2.32523014e+00 -1.94628902 0.37661733 234.00 -9.42537326e-01 -2.04221811e+00 2.24922907e+00 -2.00319406 0.38503574 234.25 -1.32799726e+00 -1.25960335e+00 1.83034896e+00 -2.38261974 0.24696335 234.50 -1.46456274e+00 -1.56343258e+00 2.14225709e+00 -2.32355417 0.29558890 234.75 -1.30948458e+00 -1.63489617e+00 2.09466832e+00 -2.24612167 0.26470912 235.00 -1.59298653e+00 -1.36547109e+00 2.09812234e+00 -2.43294682 0.24503288 235.25 -1.02642811e+00 -1.32110779e+00 1.67298549e+00 -2.23132041 0.20767452 235.50 -9.43784133e-01 -1.14957099e+00 1.48736073e+00 -2.25820453 0.17853295 235.75 -9.98317257e-01 -1.48894527e+00 1.79265037e+00 -2.16143856 0.27175573 236.00 -1.03641291e+00 -1.58009567e+00 1.88967035e+00 -2.15132046 0.28743149 236.25 -1.18398717e+00 -1.93416120e+00 2.26777538e+00 -2.12009817 0.38975476 236.50 -1.24804302e+00 -1.84340430e+00 2.22615157e+00 -2.16594039 0.32973245 236.75 -1.47047016e+00 -1.72221999e+00 2.26458036e+00 -2.27750536 0.38675816 237.00 -1.83108648e+00 -1.55075503e+00 2.39952471e+00 -2.43889855 0.44503203 237.25 -2.14315472e+00 -1.34829190e+00 2.53199589e+00 -2.58003933 0.55985715 237.50 -2.19888589e+00 -1.10233396e+00 2.45972342e+00 -2.67689379 0.46744292 237.75 -2.50894915e+00 -9.99799249e-01 2.70081920e+00 -2.76238589 0.56510420 238.00 -2.13544131e+00 -9.73566808e-01 2.34690049e+00 -2.71383572 0.49397593 238.25 -1.64294105e+00 -1.10576407e+00 1.98039630e+00 -2.54919112 0.53648650 238.50 -1.60363267e+00 -1.12637848e+00 1.95968524e+00 -2.52926324 0.42146465 238.75 -1.83164802e+00 -1.38334199e+00 2.29533647e+00 -2.49474354 0.53174922 239.00 -1.93709503e+00 -1.27644519e+00 2.31983824e+00 -2.55895269 0.49133338 239.25 -2.07048770e+00 -1.26238304e+00 2.42498047e+00 -2.59406896 0.54270627 239.50 -2.44741865e+00 -8.04923046e-01 2.57638491e+00 -2.82384954 0.51004415 239.75 -2.76761558e+00 -4.59292016e-01 2.80546701e+00 -2.97713917 0.61074271 240.00 -2.49196289e+00 -1.07969518e-01 2.49430079e+00 -3.09829264 0.44921702 240.25 -2.11267071e+00 4.75858544e-02 2.11320655e+00 3.11907243 0.44248828 240.50 -1.71777116e+00 3.66834640e-01 1.75650375e+00 2.93120028 0.26892404 240.75 -1.37473256e+00 6.26128791e-01 1.51060480e+00 2.71421163 0.30010699 241.00 -1.30080382e+00 1.15426513e+00 1.73908556e+00 2.41581197 0.28853104 241.25 -1.09324453e+00 1.20157956e+00 1.62449286e+00 2.30902109 0.30322191 241.50 -8.87880570e-01 9.11651108e-01 1.27257206e+00 2.34298597 0.22964756 241.75 -8.47561275e-01 8.15712461e-01 1.17632773e+00 2.37534042 0.27294062 242.00 -5.44883040e-01 6.90532323e-01 8.79620609e-01 2.23884121 0.15892710 242.25 -5.31464570e-01 6.58188465e-01 8.45970830e-01 2.25007294 0.20080581 242.50 -3.02855163e-01 2.55214261e-01 3.96049957e-01 2.44135536 0.04618235 242.75 -2.00210820e-01 1.79036560e-01 2.68586042e-01 2.41196890 0.02608377 243.00 -6.07733421e-02 7.22978746e-01 7.25528543e-01 1.65465883 0.15123457 243.25 1.17633154e-01 7.83984005e-01 7.92760038e-01 1.42186203 0.17251173 243.50 5.05018087e-02 6.69665072e-02 8.38745836e-02 0.92465386 0.00085328 243.75 4.94156058e-02 -1.65691482e-01 1.72903352e-01 -1.28095622 0.00238264 244.00 -5.96047035e-01 6.87500119e-01 9.09905754e-01 2.28506442 0.04065132 244.25 -4.08946686e-01 1.00844914e+00 1.08821278e+00 1.95605258 0.06434460 244.50 -6.44001166e-01 8.36644117e-01 1.05579869e+00 2.22681384 0.06874845 244.75 -2.75725332e-01 7.84370517e-01 8.31421413e-01 1.90882849 0.04870846 245.00 7.67244334e-02 8.29207240e-02 1.12971170e-01 0.82419159 0.00131098 245.25 3.46146634e-01 -4.77842894e-02 3.49429293e-01 -0.13717936 0.01337569 245.50 -3.06556364e-01 3.03703230e-02 3.08057074e-01 3.04284558 0.01460025 245.75 -1.52259041e-01 -1.51339643e-01 2.14677672e-01 -2.35922281 0.00642717 246.00 -3.25880933e-02 -6.40190735e-01 6.41019626e-01 -1.62165615 0.06574720 246.25 5.57977647e-02 -7.02749367e-01 7.04961037e-01 -1.49156331 0.07838041 246.50 4.88047926e-02 -7.71287685e-01 7.72830254e-01 -1.50760355 0.10793763 246.75 -2.21501742e-01 -9.27685130e-01 9.53762404e-01 -1.80517630 0.14020153 247.00 -4.46456876e-01 -6.53452363e-01 7.91406175e-01 -2.17017693 0.12550516 247.25 -4.25409314e-01 -7.42634174e-01 8.55849637e-01 -2.09100453 0.15674711 247.50 -1.12456129e-01 -8.12164818e-01 8.19913454e-01 -1.70838613 0.21190402 247.75 -3.39385789e-01 -7.91454562e-01 8.61152157e-01 -1.97589195 0.21771659 248.00 -4.10787692e-01 -5.53076507e-01 6.88941326e-01 -2.20962975 0.23791833 248.25 -4.40935972e-01 -4.94089964e-01 6.62230643e-01 -2.29940800 0.18076206 248.50 -4.83938464e-01 -3.55006612e-01 6.00188413e-01 -2.50868473 0.17213524 248.75 -4.19242010e-01 -3.25308387e-01 5.30649988e-01 -2.48169299 0.10191540 249.00 -3.43167700e-01 -1.99200907e-02 3.43745372e-01 -3.08361003 0.05018764 249.25 -4.93288094e-01 -7.08148713e-02 4.98345151e-01 -2.99900998 0.06221087 249.50 -2.85529497e-01 -2.43228118e-01 3.75082672e-01 -2.43602592 0.02583594 249.75 6.41937924e-02 -2.65343978e-01 2.72998662e-01 -1.33343038 0.00718027 250.00 2.87123939e-01 -7.20303380e-01 7.75420605e-01 -1.19148424 0.04268754 250.25 2.24588547e-01 -3.94616524e-01 4.54050896e-01 -1.05338385 0.00766250 250.50 -8.06611562e-01 -1.12190706e+00 1.38177338e+00 -2.19413720 0.06795757 250.75 -8.88788903e-01 -6.26971680e-01 1.08767606e+00 -2.52723670 0.05606771 251.00 -8.26257750e-01 -9.99922176e-01 1.29713000e+00 -2.26138251 0.13997646 251.25 -7.13172636e-01 -8.62896378e-01 1.11946655e+00 -2.26148051 0.10791801 251.50 -6.20705408e-01 -9.01243240e-01 1.09431009e+00 -2.17391251 0.15414186 251.75 -8.91690263e-01 -5.57950383e-01 1.05186508e+00 -2.58247418 0.14859702 252.00 -8.42578232e-01 -5.52793377e-01 1.00772943e+00 -2.56095957 0.14595613 252.25 -9.29220634e-01 -6.49534780e-01 1.13373119e+00 -2.53153124 0.23133505 252.50 -1.04054151e+00 -6.74251677e-01 1.23989595e+00 -2.56663770 0.37061523 252.75 -8.77425389e-01 -3.71257437e-01 9.52736793e-01 -2.74131429 0.25371317 253.00 -8.61026501e-01 -3.22798773e-01 9.19546455e-01 -2.78290972 0.28400154 253.25 -8.33900079e-01 -3.46085585e-01 9.02864649e-01 -2.74820505 0.21515273 253.50 -8.41106382e-01 -1.75653115e-01 8.59251978e-01 -2.93571576 0.21162476 253.75 -5.85769414e-01 -2.17853524e-01 6.24968770e-01 -2.78553374 0.09607065 254.00 -3.06771858e-01 -4.37173279e-01 5.34068768e-01 -2.18267361 0.08286406 254.25 -3.21904876e-01 -3.28394514e-01 4.59854005e-01 -2.34621536 0.05177306 254.50 -4.97146446e-01 -4.41913054e-01 6.65162939e-01 -2.41494458 0.12466438 254.75 -2.58573857e-01 -2.12247749e-01 3.34528843e-01 -2.45427297 0.03206499 255.00 -7.59903828e-02 -5.79361421e-01 5.84323707e-01 -1.70121415 0.08469835 255.25 -1.53018638e-01 -9.10878355e-01 9.23641750e-01 -1.73723249 0.23521194 255.50 -2.27434788e-01 -9.35603092e-01 9.62849796e-01 -1.80925999 0.26495934 255.75 -6.02396397e-01 -5.45735061e-01 8.12839576e-01 -2.40550540 0.20683679 256.00 -6.56549596e-01 -4.27132765e-01 7.83262262e-01 -2.56481545 0.16570120 256.25 -4.69655300e-01 -9.70672282e-02 4.79581221e-01 -2.93778465 0.08033788 256.50 -5.93554804e-01 -1.38134228e-01 6.09416418e-01 -2.91293902 0.13247103 256.75 -7.69538464e-01 -1.78192377e-01 7.89899976e-01 -2.91404555 0.21392721 257.00 -6.97459732e-01 -6.11236015e-02 7.00132967e-01 -3.05417852 0.15232719 257.25 -1.41878802e-01 5.66980989e-02 1.52788314e-01 2.76141092 0.01035150 257.50 -1.94195258e-01 -6.26199264e-02 2.04041794e-01 -2.82966110 0.01503909 257.75 -2.51427968e-01 1.62625928e-01 2.99438166e-01 2.56746378 0.03547053 258.00 -1.00308256e-01 2.43020642e-01 2.62908309e-01 1.96225076 0.02406611 258.25 5.92443143e-02 2.65271801e-01 2.71806948e-01 1.35106781 0.04179966 258.50 1.22195490e-01 2.59401409e-01 2.86741746e-01 1.13056171 0.03658472 258.75 3.44884483e-01 1.85414066e-01 3.91565681e-01 0.49328261 0.08003733 259.00 4.21007104e-01 2.02271381e-01 4.67076753e-01 0.44788279 0.10650001 259.25 4.61160912e-01 1.22101125e-01 4.77051435e-01 0.25882990 0.19982148 259.50 6.31147092e-01 1.54817540e-01 6.49857771e-01 0.24054602 0.28121533 259.75 7.74630250e-01 1.52845256e-01 7.89565511e-01 0.19481137 0.43506294 260.00 7.05576017e-01 2.30111265e-01 7.42151407e-01 0.31525586 0.29475648 260.25 7.12194128e-01 1.45397057e-01 7.26884296e-01 0.20138628 0.28833410 260.50 8.42967674e-01 1.61723550e-01 8.58340845e-01 0.18954711 0.32751260 260.75 9.14865944e-01 1.77076925e-01 9.31845445e-01 0.19119088 0.45285895 261.00 9.42423683e-01 3.14386434e-01 9.93479354e-01 0.32198470 0.40258253 261.25 1.02091246e+00 3.87577127e-01 1.09200654e+00 0.36283062 0.50638982 261.50 1.03603487e+00 4.47868264e-01 1.12869581e+00 0.40802971 0.48257038 261.75 1.08802930e+00 6.30663014e-01 1.25759437e+00 0.52531280 0.56290612 262.00 9.85614737e-01 9.15710344e-01 1.34534822e+00 0.74864857 0.46229565 262.25 1.13805054e+00 1.14279855e+00 1.61280735e+00 0.78747985 0.54151251 262.50 7.83901303e-01 1.28604659e+00 1.50612652e+00 1.02338910 0.35008624 262.75 3.92426401e-01 1.71035795e+00 1.75479993e+00 1.34525883 0.39108838 263.00 4.35740573e-01 2.06640812e+00 2.11185046e+00 1.36297237 0.39639239 263.25 2.89951216e-01 2.17906523e+00 2.19827136e+00 1.43851120 0.41105998 263.50 -1.00820044e+00 1.15748975e+00 1.53500836e+00 2.28736954 0.17898783 263.75 -1.13500877e+00 2.00636329e-01 1.15260567e+00 2.96662939 0.09153613 264.00 -9.15591635e-01 -1.32074710e+00 1.60707216e+00 -2.17696938 0.16133718 264.25 -1.31287119e+00 -1.41427850e+00 1.92971875e+00 -2.31902726 0.25271988 264.50 -1.71633616e+00 -8.46373848e-01 1.91367670e+00 -2.68345754 0.19113712 264.75 -1.81330650e+00 -1.57083516e-01 1.82009771e+00 -3.05518016 0.19532508 265.00 -1.97240961e+00 3.85260069e-03 1.97241337e+00 3.13963941 0.27681089 265.25 -1.86921290e+00 -1.71000652e-01 1.87701840e+00 -3.05036388 0.30006658 265.50 -1.95639553e+00 -7.40412807e-01 2.09181610e+00 -2.77979409 0.32208706 265.75 -2.03066290e+00 -8.59005653e-01 2.20487699e+00 -2.74140252 0.35998491 266.00 -1.93283223e+00 -8.15773280e-01 2.09793386e+00 -2.74221392 0.44425293 266.25 -1.85861740e+00 -8.45680576e-01 2.04196824e+00 -2.71458421 0.44461652 266.50 -1.77943635e+00 -8.48528121e-01 1.97139384e+00 -2.69663418 0.46644306 266.75 -1.65331082e+00 -9.07006909e-01 1.88576197e+00 -2.63982466 0.44469647 267.00 -1.70653927e+00 -4.75682724e-01 1.77159542e+00 -2.86975166 0.43693434 267.25 -1.50987975e+00 -4.23019446e-01 1.56801859e+00 -2.86842850 0.36031184 267.50 -1.30943365e+00 -8.60266271e-01 1.56674010e+00 -2.56032912 0.39701986 267.75 -1.11584946e+00 -7.37450569e-01 1.33751761e+00 -2.55760194 0.29943280 268.00 -6.62429197e-01 -8.35463034e-01 1.06621336e+00 -2.24118604 0.27721000 268.25 -6.16211513e-01 -1.02428551e+00 1.19535662e+00 -2.11239243 0.26892724 268.50 -9.68457091e-01 -1.07395801e+00 1.44613103e+00 -2.30458537 0.40125721 268.75 -7.90656549e-01 -8.62375956e-01 1.16997011e+00 -2.31283512 0.25095733 269.00 -1.86475439e-01 -8.61321564e-01 8.81276305e-01 -1.78400502 0.15343375 269.25 -2.28998040e-01 -9.76368873e-01 1.00286404e+00 -1.80117279 0.16317901 269.50 -8.63857573e-02 -1.52285975e+00 1.52530794e+00 -1.62746161 0.37868735 269.75 -4.47792379e-02 -1.52761848e+00 1.52827465e+00 -1.60010104 0.31105924 270.00 1.03195552e-01 -1.34233228e+00 1.34629316e+00 -1.49406945 0.29979428 270.25 1.79205039e-01 -1.13444807e+00 1.14851507e+00 -1.41412422 0.15822088 270.50 5.71039118e-01 -9.81249379e-01 1.13531318e+00 -1.04375383 0.16409772 270.75 1.00335689e+00 -1.23846275e+00 1.59389932e+00 -0.88988899 0.19786037 271.00 1.58872188e+00 -1.46624001e+00 2.16191974e+00 -0.74532686 0.31517245 271.25 1.78166521e+00 -1.56947756e+00 2.37436112e+00 -0.72216458 0.24533616 271.50 2.48662061e+00 -1.76263504e+00 3.04797709e+00 -0.61663930 0.27662269 271.75 1.76087015e+00 -9.01478549e-01 1.97821315e+00 -0.47316233 0.11306620 272.00 1.61272465e+00 -1.55396424e+00 2.23957265e+00 -0.76684450 0.17083498 272.25 1.39036878e+00 -1.74199269e+00 2.22882567e+00 -0.89718539 0.10358664 272.50 2.83754110e+00 -1.87523493e+00 3.40119767e+00 -0.58397612 0.25104885 272.75 2.63055997e+00 -1.25725920e+00 2.91556966e+00 -0.44584727 0.14245784 273.00 2.85937913e+00 -3.44443915e-01 2.88005046e+00 -0.11988344 0.12933140 273.25 2.02293026e+00 1.04985620e+00 2.27913249e+00 0.47871445 0.07863552 273.50 3.06244629e+00 1.06185871e+00 3.24131474e+00 0.33376359 0.14159089 273.75 7.94380836e-01 2.56197152e+00 2.68230107e+00 1.27013024 0.08094157 274.00 6.36921542e-01 4.75501241e+00 4.79747977e+00 1.43764150 0.21885274 274.25 -8.85079564e-01 4.91824255e+00 4.99724680e+00 1.74884907 0.38488462 274.50 -1.18098058e+00 4.53913009e+00 4.69024702e+00 1.82533086 0.42392377 274.75 -1.06581595e+00 4.12262557e+00 4.25816924e+00 1.82378551 0.45879521 275.00 -1.38506614e+00 4.22980249e+00 4.45080188e+00 1.88724626 0.55461512 275.25 -1.87602864e+00 2.93904596e+00 3.48675703e+00 2.13891118 0.51875353 275.50 -1.74800759e+00 2.76216741e+00 3.26880702e+00 2.13501291 0.57747616 275.75 -2.47642156e+00 2.68996538e+00 3.65630654e+00 2.31488470 0.72174435 276.00 -2.34434101e+00 2.39604872e+00 3.35216113e+00 2.34528702 0.68158521 276.25 -1.62709115e+00 1.81368684e+00 2.43657250e+00 2.30201689 0.59832305 276.50 -1.74424089e+00 1.53846119e+00 2.32577710e+00 2.41879865 0.64448044 276.75 -1.84180360e+00 1.39298766e+00 2.30925424e+00 2.49406081 0.71773720 277.00 -1.81177390e+00 1.28501382e+00 2.22121255e+00 2.52468073 0.67499950 277.25 -2.05035711e+00 1.15938324e+00 2.35544768e+00 2.62696181 0.69092452 277.50 -2.09389628e+00 1.28663320e+00 2.45760587e+00 2.59060246 0.72031946 277.75 -2.01865602e+00 9.14193377e-01 2.21601481e+00 2.71635270 0.76448856 278.00 -1.88593382e+00 9.17415483e-01 2.09723569e+00 2.68884241 0.73488021 278.25 -1.78163361e+00 7.17694897e-01 1.92075618e+00 2.75864928 0.74796218 278.50 -1.73974361e+00 6.72156578e-01 1.86507434e+00 2.77290530 0.71573617 278.75 -1.63862117e+00 5.01102306e-01 1.71352936e+00 2.84481662 0.73051990 279.00 -1.66344479e+00 3.52628575e-01 1.70041039e+00 2.93269820 0.69276287 279.25 -1.75046109e+00 2.30149835e-01 1.76552626e+00 3.01086297 0.78251501 279.50 -1.80018929e+00 3.01460389e-01 1.82525611e+00 2.97567181 0.73274600 279.75 -1.71326610e+00 4.22323387e-01 1.76455030e+00 2.89990900 0.77237137 280.00 -1.72679868e+00 3.91747578e-01 1.77067779e+00 2.91850522 0.74616683 280.25 -1.80248584e+00 3.27235390e-01 1.83194929e+00 2.96200194 0.77812146 280.50 -1.76410834e+00 2.86236586e-01 1.78717923e+00 2.98073880 0.67771388 280.75 -1.79266669e+00 4.08796208e-01 1.83868654e+00 2.91738844 0.73091345 281.00 -1.70949287e+00 4.81466820e-01 1.77600005e+00 2.86706098 0.57863772 281.25 -1.43072269e+00 2.07483244e-01 1.44568901e+00 2.99757675 0.50987660 281.50 -1.35222327e+00 4.06240687e-01 1.41192750e+00 2.84974667 0.38567125 281.75 -1.30826541e+00 5.47711501e-01 1.41828991e+00 2.74510876 0.38489394 282.00 -1.19521844e+00 2.92740602e-01 1.23054629e+00 2.90139477 0.33576975 282.25 -1.12211225e+00 1.44338244e-01 1.13135734e+00 3.01366429 0.44770438 282.50 -1.05657501e+00 2.34838936e-01 1.08235857e+00 2.92288358 0.45106544 282.75 -9.41247779e-01 2.03217837e-01 9.62935549e-01 2.92895394 0.46573561 283.00 -1.01640287e+00 -1.11002408e-01 1.02244624e+00 -3.03281273 0.51494607 283.25 -1.04146924e+00 -2.40057592e-01 1.06877772e+00 -2.91505041 0.62801133 283.50 -9.53035666e-01 -3.03584397e-01 1.00022021e+00 -2.83321045 0.49622662 283.75 -9.62151219e-01 -3.88101973e-01 1.03747680e+00 -2.75818535 0.61217592 284.00 -9.94622922e-01 -4.30264697e-01 1.08369851e+00 -2.73331016 0.58659307 284.25 -1.09720434e+00 -4.65603809e-01 1.19190783e+00 -2.74026871 0.68048034 284.50 -1.07265316e+00 -4.98282517e-01 1.18273846e+00 -2.70671923 0.61219872 284.75 -1.17649992e+00 -4.97358225e-01 1.27730860e+00 -2.74163445 0.67961916 285.00 -1.05041821e+00 -3.58128004e-01 1.10979011e+00 -2.81301314 0.59098224 285.25 -1.02697924e+00 -3.65751213e-01 1.09016526e+00 -2.79945596 0.63503591 285.50 -1.05116274e+00 -4.94829996e-01 1.16180886e+00 -2.70162143 0.69984812 285.75 -1.06991981e+00 -4.95084401e-01 1.17891347e+00 -2.70820272 0.73523202 286.00 -1.03550969e+00 -5.05547941e-01 1.15232766e+00 -2.68742008 0.69696681 286.25 -1.00544242e+00 -5.69335215e-01 1.15544669e+00 -2.62635650 0.70714504 286.50 -1.05794543e+00 -5.69845371e-01 1.20165398e+00 -2.64751760 0.74917248 286.75 -1.07291801e+00 -5.46971449e-01 1.20429681e+00 -2.67013741 0.75883725 287.00 -1.17298029e+00 -6.45859325e-01 1.33903585e+00 -2.63827819 0.70633891 287.25 -1.26396538e+00 -5.31627034e-01 1.37121690e+00 -2.74345259 0.68217083 287.50 -1.06561248e+00 -3.59658759e-01 1.12467079e+00 -2.81608454 0.62196467 287.75 -9.46690771e-01 -2.55413755e-01 9.80540465e-01 -2.87807060 0.53808064 288.00 -7.76024797e-01 -2.78484901e-01 8.24480640e-01 -2.79704591 0.53837227 288.25 -7.05949464e-01 -2.89956350e-01 7.63177130e-01 -2.75186854 0.47529126 288.50 -6.38388190e-01 -4.82131744e-01 7.99994063e-01 -2.49475091 0.57357013 288.75 -6.49605230e-01 -5.57483347e-01 8.56022568e-01 -2.43236426 0.54951030 289.00 -6.10030985e-01 -8.14312262e-01 1.01746856e+00 -2.21374452 0.68780943 289.25 -5.92423426e-01 -8.62459521e-01 1.04632784e+00 -2.17267612 0.67980969 289.50 -5.84893665e-01 -8.38237340e-01 1.02212643e+00 -2.18002151 0.70366505 289.75 -6.40407528e-01 -8.38668394e-01 1.05521869e+00 -2.22294503 0.69872565 290.00 -6.11140164e-01 -8.20093257e-01 1.02276354e+00 -2.21122358 0.74689683 290.25 -6.56145639e-01 -8.55119891e-01 1.07784838e+00 -2.22528675 0.65543373 290.50 -7.50367521e-01 -9.66922366e-01 1.22392413e+00 -2.23075393 0.77188822 290.75 -7.77121376e-01 -9.32237719e-01 1.21366585e+00 -2.26569703 0.74572481 291.00 -8.09388242e-01 -8.77239362e-01 1.19359048e+00 -2.31598730 0.81756813 291.25 -7.76629470e-01 -8.98664591e-01 1.18775055e+00 -2.28347892 0.78464806 291.50 -7.31023160e-01 -9.17570294e-01 1.17317096e+00 -2.24351844 0.80465016 291.75 -8.32794381e-01 -9.49296630e-01 1.26281850e+00 -2.29091348 0.76890876 292.00 -9.10569131e-01 -9.54825007e-01 1.31940401e+00 -2.33247426 0.85864173 292.25 -9.96245811e-01 -8.94640851e-01 1.33898767e+00 -2.40987689 0.73522746 292.50 -1.13725550e+00 -8.11889973e-01 1.39732437e+00 -2.52159671 0.76478934 292.75 -1.21446318e+00 -6.42668425e-01 1.37402457e+00 -2.65487524 0.61949147 293.00 -1.38970539e+00 -3.19590335e-01 1.42598003e+00 -2.91555290 0.63430688 293.25 -1.33664750e+00 2.86973942e-01 1.36710665e+00 2.93010632 0.51819804 293.50 -1.32571377e+00 8.18240309e-01 1.55789416e+00 2.58861666 0.58710224 293.75 -7.03141834e-01 1.30668625e+00 1.48385896e+00 2.06446566 0.47448295 294.00 -1.08314955e-01 1.64523822e+00 1.64879984e+00 1.63653688 0.59104039 294.25 1.51259824e+00 2.02556471e+00 2.52801619e+00 0.92937600 0.62532619 294.50 2.74016799e+00 1.62299891e+00 3.18475212e+00 0.53473780 0.73165349 294.75 3.59818302e+00 5.43781495e-01 3.63904100e+00 0.14999166 0.67169094 295.00 3.97333036e+00 -1.05078629e+00 4.10992774e+00 -0.25854094 0.68368456 295.25 2.99986829e+00 -3.51748519e+00 4.62297651e+00 -0.86465314 0.81836734 295.50 2.40334556e+00 -4.18587050e+00 4.82675686e+00 -1.04959605 0.84857361 295.75 6.27249926e-01 -4.09655834e+00 4.14430123e+00 -1.41886004 0.78485202 296.00 -2.13881231e-01 -3.96591112e+00 3.97167423e+00 -1.62467404 0.84006661 296.25 -1.12905801e+00 -3.31231069e+00 3.49945340e+00 -1.89931195 0.87120027 296.50 -1.26376511e+00 -2.84088321e+00 3.10929568e+00 -1.98935874 0.85724209 296.75 -1.17425554e+00 -1.87402557e+00 2.21152615e+00 -2.13054197 0.79097879 297.00 -1.12432957e+00 -1.62333446e+00 1.97467256e+00 -2.17654195 0.81211900 297.25 -8.62730902e-01 -1.30036157e+00 1.56052709e+00 -2.15657191 0.79921196 297.50 -7.00820120e-01 -1.12722365e+00 1.32732136e+00 -2.12703520 0.77276381 297.75 -4.28600112e-01 -1.08491643e+00 1.16650835e+00 -1.94703128 0.74116799 298.00 -3.34132897e-01 -9.83457754e-01 1.03866932e+00 -1.89831357 0.68301336 298.25 -1.71337271e-01 -8.39134174e-01 8.56447676e-01 -1.77221113 0.68332851 298.50 -2.34859365e-02 -8.14852937e-01 8.15191326e-01 -1.59961065 0.65709951 298.75 1.78024469e-01 -7.40838219e-01 7.61927804e-01 -1.33496637 0.77213687 299.00 2.21900834e-01 -7.14052308e-01 7.47737038e-01 -1.26949496 0.75375346 299.25 3.66245155e-01 -6.72770008e-01 7.65999346e-01 -1.07227513 0.78895991 299.50 4.62041880e-01 -6.64301552e-01 8.09184312e-01 -0.96307644 0.76132872 299.75 6.29172980e-01 -6.46772257e-01 9.02315350e-01 -0.79919042 0.77232131 300.00 6.81145402e-01 -6.68703399e-01 9.54527786e-01 -0.77618109 0.73399022 300.25 7.73092154e-01 -7.45323883e-01 1.07386180e+00 -0.76711255 0.77912871 300.50 8.79614105e-01 -7.59845445e-01 1.16236228e+00 -0.71247396 0.77350093 300.75 9.92697634e-01 -7.60930960e-01 1.25078556e+00 -0.65399566 0.84968467 301.00 9.23287974e-01 -7.94811226e-01 1.21827155e+00 -0.71075866 0.76588495 301.25 9.63116726e-01 -7.38509520e-01 1.21366805e+00 -0.65416121 0.82544088 301.50 9.93978165e-01 -6.56982601e-01 1.19147754e+00 -0.58404338 0.76215664 301.75 1.02887047e+00 -5.45878989e-01 1.16471384e+00 -0.48779679 0.78034363 302.00 1.07497722e+00 -5.19282199e-01 1.19382998e+00 -0.45000679 0.77647879 302.25 1.12539538e+00 -4.44850258e-01 1.21012665e+00 -0.37643385 0.82717115 302.50 1.11554305e+00 -4.29062423e-01 1.19521164e+00 -0.36717961 0.77227118 302.75 1.22128490e+00 -3.70885024e-01 1.27635909e+00 -0.29483343 0.82144295 303.00 1.25428538e+00 -2.76361512e-01 1.28437047e+00 -0.21686871 0.80049845 303.25 1.29670535e+00 -2.16125721e-01 1.31459313e+00 -0.16515480 0.83859099 303.50 1.36381995e+00 -1.62215469e-02 1.36391642e+00 -0.01189364 0.74727605 303.75 1.41051558e+00 1.77877497e-01 1.42168723e+00 0.12544594 0.80448174 304.00 1.32622953e+00 1.88671729e-01 1.33958269e+00 0.14131352 0.76626391 304.25 1.28934877e+00 2.45698664e-01 1.31255022e+00 0.18830265 0.75458571 304.50 1.34042485e+00 4.12922043e-01 1.40258454e+00 0.29882850 0.77011816 304.75 1.32685390e+00 5.63726906e-01 1.44164118e+00 0.40175190 0.78692528 305.00 1.32862716e+00 6.39242039e-01 1.47440853e+00 0.44843776 0.75366483 305.25 1.30171078e+00 6.78457922e-01 1.46790875e+00 0.48046720 0.77192068 305.50 1.13437264e+00 8.99322455e-01 1.44761257e+00 0.67033083 0.82251251 305.75 1.08311042e+00 9.59475039e-01 1.44696943e+00 0.72494306 0.84055823 306.00 1.12247349e+00 1.31633345e+00 1.72993656e+00 0.86472104 0.82666211 306.25 1.09362885e+00 1.46071773e+00 1.82475213e+00 0.92813235 0.86353542 306.50 1.02158563e+00 1.55810830e+00 1.86315289e+00 0.99045412 0.81199088 306.75 9.61010191e-01 1.67262154e+00 1.92904209e+00 1.04929783 0.78512994 307.00 8.49064428e-01 2.17227122e+00 2.33231058e+00 1.19818981 0.79305746 307.25 7.38441580e-01 2.32253935e+00 2.43710587e+00 1.26295790 0.78498549 307.50 3.64812172e-01 2.55479162e+00 2.58070690e+00 1.42895990 0.79714620 307.75 -1.46792408e-02 2.48994951e+00 2.48999278e+00 1.57669166 0.66376734 308.00 -1.14593483e+00 3.04531573e+00 3.25378464e+00 1.93070121 0.44093963 308.25 -1.40716428e+00 2.35768439e+00 2.74568516e+00 2.10889028 0.21236004 308.50 -3.44706624e-01 -1.07998658e+00 1.13366383e+00 -1.87975233 0.01826946 308.75 1.71706906e+00 -2.02780097e+00 2.65712306e+00 -0.86818387 0.19783884 309.00 2.25389383e+00 -1.59100692e+00 2.75886578e+00 -0.61466977 0.55903612 309.25 2.00969576e+00 -1.52483808e+00 2.52269860e+00 -0.64907176 0.56248767 309.50 1.67922376e+00 -1.16045938e+00 2.04119044e+00 -0.60470678 0.56675508 309.75 1.42338096e+00 -7.05956431e-01 1.58883222e+00 -0.46041964 0.51069380 310.00 1.36395890e+00 -2.65935163e-01 1.38964218e+00 -0.19255727 0.53857253 310.25 1.11792393e+00 3.39509975e-02 1.11843935e+00 0.03036035 0.41945857 310.50 1.05357369e+00 7.14092280e-02 1.05599091e+00 0.06767460 0.48728060 310.75 8.48228534e-01 1.27454878e-01 8.57750775e-01 0.14914428 0.30706626 311.00 3.75466855e-01 1.49683232e-01 4.04203450e-01 0.37934979 0.13903079 311.25 3.96591047e-02 3.76704071e-01 3.78785957e-01 1.46590352 0.13777274 311.50 -1.83630845e-01 5.79492725e-01 6.07891524e-01 1.87766839 0.39632349 311.75 -3.38957119e-01 8.37165583e-01 9.03182231e-01 1.95550817 0.54725414 312.00 -5.15929643e-01 1.18999461e+00 1.29702374e+00 1.97989185 0.72740388 312.25 -5.69152432e-01 1.77151748e+00 1.86070113e+00 1.88165958 0.75009413 312.50 -4.12686257e-01 2.14105317e+00 2.18046294e+00 1.76121033 0.87615779 312.75 -3.88631217e-01 2.10352019e+00 2.13911931e+00 1.75348905 0.89283859 313.00 -3.54675308e-01 2.09422941e+00 2.12405070e+00 1.73856282 0.92822004 313.25 -6.11707635e-01 2.17325016e+00 2.25769849e+00 1.84516888 0.94211815 313.50 -8.04469192e-01 2.23786876e+00 2.37807217e+00 1.91589154 0.96311938 313.75 -1.06733792e+00 2.72326140e+00 2.92495520e+00 1.94432972 0.94439471 314.00 -1.31388189e+00 3.17112287e+00 3.43253636e+00 1.96359225 0.95597580 314.25 -1.64209007e+00 3.65830721e+00 4.00994656e+00 1.99270690 0.91006325 314.50 -1.90474521e+00 4.30063604e+00 4.70356510e+00 1.98772897 0.88298943 314.75 -5.08001318e-01 5.67583081e+00 5.69851917e+00 1.66006102 0.68185456 315.00 3.52417811e+00 6.48016387e+00 7.37647308e+00 1.07269409 0.61705973 315.25 5.83717994e+00 2.60586014e+00 6.39243120e+00 0.41987656 0.65214878 315.50 5.13651685e+00 1.19351586e+00 5.27335619e+00 0.22830770 0.72943976 315.75 3.28636147e+00 -1.33681587e-01 3.28907928e+00 -0.04065527 0.72035421 316.00 2.84952858e+00 -4.94327987e-01 2.89208805e+00 -0.17176765 0.84208798 316.25 2.16061602e+00 -2.45929724e-01 2.17456732e+00 -0.11333612 0.81490999 316.50 1.81095731e+00 -1.07689674e-01 1.81415640e+00 -0.05939566 0.82379729 316.75 1.33297853e+00 -4.12952321e-02 1.33361803e+00 -0.03096976 0.82086801 317.00 1.17104214e+00 2.07886162e-02 1.17122665e+00 0.01775037 0.82173815 317.25 9.67692060e-01 2.17253397e-01 9.91779694e-01 0.22084491 0.79963096 317.50 8.17430858e-01 3.03182756e-01 8.71844591e-01 0.35516879 0.80015739 317.75 7.47019514e-01 3.27359733e-01 8.15599503e-01 0.41301555 0.80165148 318.00 7.00961989e-01 3.44576736e-01 7.81076717e-01 0.45688647 0.76656706 318.25 5.48400897e-01 3.54416409e-01 6.52958295e-01 0.57375036 0.74514575 318.50 5.22944182e-01 3.80966177e-01 6.46997562e-01 0.62960020 0.75322289 318.75 4.36820123e-01 3.66161984e-01 5.69988086e-01 0.69762957 0.65217138 319.00 4.02117602e-01 3.86867130e-01 5.58000665e-01 0.76607133 0.61130167 319.25 3.99118109e-01 3.07098694e-01 5.03591971e-01 0.65582904 0.57984338 319.50 3.94246259e-01 3.06267521e-01 4.99229314e-01 0.66046058 0.50758437 319.75 3.00880493e-01 2.11961544e-01 3.68044518e-01 0.61372025 0.36572016 320.00 2.72519252e-01 1.15801746e-01 2.96102663e-01 0.40181179 0.21778840 320.25 2.33606067e-01 9.97343569e-02 2.54005387e-01 0.40350756 0.18538178 320.50 1.30270768e-01 3.89079729e-02 1.35956991e-01 0.29023618 0.03917033 320.75 -3.43959669e-02 -1.09112031e-01 1.14405061e-01 -1.87617122 0.02959002 321.00 -2.22496244e-01 -1.81429222e-01 2.87090824e-01 -2.45751614 0.13784398 321.25 -3.48997102e-01 -1.70924214e-01 3.88605281e-01 -2.68617195 0.30567882 321.50 -4.25448460e-01 -2.22476607e-01 4.80106480e-01 -2.65977559 0.39059274 321.75 -5.03788879e-01 -2.58785878e-01 5.66368577e-01 -2.66706165 0.62449500 322.00 -5.86077035e-01 -3.20150156e-01 6.67819147e-01 -2.64162575 0.60905267 322.25 -8.25661498e-01 -3.90119509e-01 9.13186805e-01 -2.70019156 0.70943930 322.50 -9.47260052e-01 -3.47738109e-01 1.00907056e+00 -2.78976692 0.67599340 322.75 -9.67042257e-01 -3.06821272e-01 1.01454917e+00 -2.83436078 0.72463936 323.00 -1.07714985e+00 -2.13176313e-01 1.09804187e+00 -2.94620967 0.70920625 323.25 -1.15759749e+00 -1.73636692e-01 1.17054759e+00 -2.99270518 0.83651301 323.50 -1.23225517e+00 -1.51881179e-01 1.24157992e+00 -3.01895653 0.82672097 323.75 -1.26461256e+00 -1.17966048e-01 1.27010272e+00 -3.04857946 0.86505370 324.00 -1.45574795e+00 -6.30878584e-02 1.45711433e+00 -3.09828268 0.85313718 324.25 -1.47135332e+00 -9.14019137e-02 1.47418958e+00 -3.07955140 0.90733340 324.50 -1.58423936e+00 -8.98362536e-02 1.58678445e+00 -3.08494708 0.86250292 324.75 -1.70310363e+00 -1.25364704e-01 1.70771142e+00 -3.06811561 0.90171906 325.00 -1.78251867e+00 -1.78346203e-01 1.79141848e+00 -3.04187160 0.88784567 325.25 -1.98366627e+00 -1.81445348e-01 1.99194736e+00 -3.05037679 0.92883675 325.50 -2.21382188e+00 -6.00928950e-02 2.21463732e+00 -3.11445490 0.93683597 325.75 -2.24419245e+00 -6.50249830e-02 2.24513430e+00 -3.11262598 0.93836348 326.00 -2.57137166e+00 -9.79626281e-02 2.57323704e+00 -3.10351365 0.93020082 326.25 -2.77719139e+00 -1.36169224e-02 2.77722477e+00 -3.13668957 0.95126923 326.50 -3.21704927e+00 1.28392853e-01 3.21961034e+00 3.10170369 0.92664685 326.75 -3.57808350e+00 3.71302881e-01 3.59729723e+00 3.03819131 0.94607075 327.00 -3.91160855e+00 8.22725563e-01 3.99719387e+00 2.93428517 0.94432798 327.25 -4.02064915e+00 1.14500946e+00 4.18051029e+00 2.86415491 0.95049600 327.50 -4.01385014e+00 1.93643294e+00 4.45654187e+00 2.69209328 0.93108374 327.75 -4.19917934e+00 2.44522243e+00 4.85924066e+00 2.61428237 0.92594027 328.00 -3.89850146e+00 3.80146503e+00 5.44513085e+00 2.36879601 0.93935105 328.25 -3.58731297e+00 4.48085816e+00 5.73993938e+00 2.24589457 0.93802105 328.50 -2.69222421e+00 5.59045248e+00 6.20493595e+00 2.01959589 0.91268313 328.75 -1.53404388e+00 5.76544221e+00 5.96603842e+00 1.83084687 0.87289831 329.00 7.00620127e-01 4.98787556e+00 5.03684139e+00 1.43124471 0.84123577 329.25 1.35245632e+00 4.22755458e+00 4.43862094e+00 1.26117088 0.81472545 329.50 1.52733547e+00 2.39218191e+00 2.83818391e+00 1.00256958 0.77956985 329.75 1.35640143e+00 1.80110692e+00 2.25473080e+00 0.92531849 0.75134505 330.00 1.24105361e+00 1.34571940e+00 1.83062141e+00 0.82583802 0.75221360 330.25 9.08951441e-01 1.19028793e+00 1.49765753e+00 0.91862264 0.67314666 330.50 6.40579271e-01 9.13299331e-01 1.11555254e+00 0.95913790 0.61282796 330.75 4.56310842e-01 9.78376308e-01 1.07955536e+00 1.13439141 0.49889623 331.00 4.04009224e-02 1.06294355e+00 1.06371107e+00 1.53280608 0.58257862 331.25 1.37424577e-01 1.02994170e+00 1.03906950e+00 1.43815034 0.59284032 331.50 4.23908673e-01 1.10211742e+00 1.18083080e+00 1.20360877 0.72693619 331.75 5.70176890e-01 1.00525148e+00 1.15569556e+00 1.05484503 0.64264862 332.00 7.89760987e-01 7.76232352e-01 1.10736583e+00 0.77675937 0.65763506 332.25 9.02636407e-01 6.22180261e-01 1.09629410e+00 0.60350333 0.51146221 332.50 9.26866860e-01 3.84273855e-01 1.00336861e+00 0.39302414 0.53302790 332.75 7.60889404e-01 1.24097240e-01 7.70942806e-01 0.16167152 0.35790891 333.00 6.58116013e-01 -1.91031197e-01 6.85280676e-01 -0.28250626 0.33689762 333.25 7.77600449e-01 -5.62597700e-01 9.59780511e-01 -0.62632747 0.37730874 333.50 1.05455836e+00 -9.12493950e-01 1.39453883e+00 -0.71330137 0.68227280 333.75 8.78580606e-01 -1.33662612e+00 1.59952283e+00 -0.98929791 0.64389697 334.00 6.69632871e-01 -1.77011004e+00 1.89253738e+00 -1.20913553 0.75729893 334.25 2.28601218e-01 -2.09203532e+00 2.10448813e+00 -1.46195600 0.75925231 334.50 -1.22367924e-01 -2.25574663e+00 2.25906325e+00 -1.62499040 0.84311082 334.75 -6.59585766e-01 -2.38297944e+00 2.47257849e+00 -1.84082627 0.84305015 335.00 -9.32385755e-01 -2.49959446e+00 2.66782977e+00 -1.92782542 0.88342437 335.25 -1.16205983e+00 -2.77331854e+00 3.00693843e+00 -1.96758604 0.87711362 335.50 -1.46001811e+00 -3.07795850e+00 3.40668188e+00 -2.01371114 0.87991604 335.75 -2.35492095e+00 -3.62922698e+00 4.32630803e+00 -2.14638150 0.89632866 336.00 -3.18598653e+00 -3.73916298e+00 4.91241793e+00 -2.27648439 0.92285053 336.25 -4.37554308e+00 -3.42940478e+00 5.55933399e+00 -2.47682877 0.90925987 336.50 -5.41145888e+00 -2.69200765e+00 6.04407085e+00 -2.67997565 0.91539049 336.75 -6.10924958e+00 -1.38274136e+00 6.26377714e+00 -2.91900722 0.94501790 337.00 -6.09353083e+00 -8.24850846e-01 6.14910537e+00 -3.00704547 0.96032880 337.25 -6.27299172e+00 -7.05911239e-01 6.31258550e+00 -3.02953226 0.96089993 337.50 -6.73451408e+00 -2.98933456e-01 6.74114539e+00 -3.09723350 0.96155713 337.75 -7.47232591e+00 6.16826272e-01 7.49774161e+00 3.05923129 0.97365379 338.00 -7.79777762e+00 1.17467408e+00 7.88575900e+00 2.99207473 0.96449239 338.25 -8.06222858e+00 3.00243685e+00 8.60314807e+00 2.78509653 0.96698516 338.50 -7.88344490e+00 3.89780908e+00 8.79440841e+00 2.68241123 0.97305966 338.75 -7.37793825e+00 5.75635530e+00 9.35786296e+00 2.47903462 0.97630077 339.00 -7.15198034e+00 6.47788769e+00 9.64955189e+00 2.40561125 0.97146297 339.25 -6.37894850e+00 8.43009298e+00 1.05715397e+01 2.21856391 0.97065757 339.50 -5.81451229e+00 9.23526627e+00 1.09132349e+01 2.13269579 0.96362319 339.75 -3.71752179e+00 1.13418547e+01 1.19355618e+01 1.88753172 0.96124177 340.00 -2.36859720e+00 1.21256201e+01 1.23547932e+01 1.76370543 0.95366198 340.25 1.36812720e+00 1.23679942e+01 1.24434341e+01 1.46062588 0.94988925 340.50 3.14123781e+00 1.21304670e+01 1.25305867e+01 1.31740791 0.91895821 340.75 6.43170904e+00 1.01768296e+01 1.20388846e+01 1.00718245 0.92685182 341.00 7.43863553e+00 8.75177105e+00 1.14859390e+01 0.86632680 0.91421057 341.25 8.18105315e+00 6.62170611e+00 1.05250474e+01 0.68044360 0.92423417 341.50 8.06044885e+00 4.94241897e+00 9.45506959e+00 0.55004650 0.86271700 341.75 7.78576078e+00 2.35724298e+00 8.13478121e+00 0.29399004 0.79073365 342.00 7.01253145e+00 1.35386570e+00 7.14202700e+00 0.19071729 0.75580068 342.25 6.96171691e+00 1.52207008e-01 6.96338060e+00 0.02185995 0.81336155 342.50 5.35089408e+00 -7.96221029e-02 5.35148644e+00 -0.01487905 0.66150609 342.75 3.05683330e+00 -3.08696384e-01 3.07238072e+00 -0.10064448 0.56840061 343.00 2.59705017e+00 -5.93611751e-02 2.59772850e+00 -0.02285317 0.44632460 343.25 2.39065137e+00 3.25030486e-01 2.41264560e+00 0.13513041 0.44410918 343.50 1.58608046e+00 1.15443703e+00 1.96172783e+00 0.62917720 0.27452108 343.75 8.20086958e-01 2.21026972e+00 2.35750606e+00 1.21550653 0.40709906 344.00 1.32240739e-01 3.14973735e+00 3.15251217e+00 1.52883628 0.57766989 344.25 -3.24917647e-01 4.02943401e+00 4.04251283e+00 1.65125829 0.71445177 344.50 -1.31412780e+00 5.20536140e+00 5.36867946e+00 1.81808574 0.70461804 344.75 -2.49597513e+00 6.86424400e+00 7.30395355e+00 1.91955271 0.82190627 345.00 -5.46281819e+00 8.62180605e+00 1.02067587e+01 2.13555949 0.81507597 345.25 -8.56489037e+00 1.06696961e+01 1.36820964e+01 2.24719998 0.86307697 345.50 -1.50813391e+01 1.38742490e+01 2.04924761e+01 2.39785801 0.77011760 345.75 -2.22696266e+01 1.62772887e+01 2.75841693e+01 2.51041577 0.68721021 346.00 -9.37623459e+00 9.27937015e+00 1.31916824e+01 2.36138669 0.12598730 346.25 7.67662014e+00 -5.78099075e-01 7.69835667e+00 -0.07516458 0.04439707 346.50 6.65444688e+00 3.80370706e+00 7.66484512e+00 0.51927819 0.11509958 346.75 4.61001034e+00 4.81772325e+00 6.66803214e+00 0.80742671 0.10851489 347.00 4.09480610e+00 1.43602879e+00 4.33931051e+00 0.33729401 0.05503021 347.25 6.26851765e+00 -2.95475058e+00 6.92999743e+00 -0.44047712 0.15726384 347.50 1.28778124e+01 -3.46697118e+00 1.33363391e+01 -0.26298516 0.61422598 347.75 1.50411822e+01 -3.45910629e+00 1.54338129e+01 -0.22604530 0.74946763 348.00 1.68109570e+01 -1.60589155e+00 1.68874854e+01 -0.09523749 0.85224190 348.25 1.69241962e+01 -1.91797835e-01 1.69252830e+01 -0.01133227 0.87292217 348.50 1.72398472e+01 2.86009546e+00 1.74754822e+01 0.16440291 0.87649779 348.75 1.74821541e+01 4.47906460e+00 1.80468205e+01 0.25081273 0.89914581 349.00 1.89397022e+01 6.30819144e+00 1.99626050e+01 0.32151091 0.92902628 349.25 1.94728142e+01 6.41634998e+00 2.05026837e+01 0.31829927 0.92970654 349.50 1.85285735e+01 7.16077486e+00 1.98641570e+01 0.36879019 0.93307251 349.75 1.83760165e+01 6.98947014e+00 1.96603834e+01 0.36346005 0.93023087 350.00 1.99325232e+01 5.77476666e+00 2.07521905e+01 0.28199524 0.93177073 350.25 1.93915791e+01 5.21193550e+00 2.00797812e+01 0.26256798 0.92492215 350.50 1.78464270e+01 4.31713948e+00 1.83611723e+01 0.23734543 0.94238715 350.75 1.68015223e+01 3.66329103e+00 1.71962453e+01 0.21467361 0.94773484 351.00 1.55133294e+01 2.64563167e+00 1.57373046e+01 0.16891422 0.94986572 351.25 1.46593834e+01 2.37705859e+00 1.48508562e+01 0.16075352 0.96201704 351.50 1.38971143e+01 2.00368783e+00 1.40408173e+01 0.14319335 0.97658334 351.75 1.32523776e+01 1.69136377e+00 1.33598737e+01 0.12694093 0.97133000 352.00 1.23540395e+01 1.38586368e+00 1.24315289e+01 0.11171195 0.95828692 352.25 1.14711855e+01 1.26236066e+00 1.15404355e+01 0.10960520 0.95474468 352.50 1.08805524e+01 8.28908055e-01 1.09120809e+01 0.07603566 0.96521614 352.75 9.90837756e+00 4.40448813e-01 9.91816218e+00 0.04442292 0.95853200 353.00 8.84296221e+00 4.91322354e-01 8.85660084e+00 0.05550377 0.95940571 353.25 7.95170574e+00 5.67685400e-01 7.97194399e+00 0.07127073 0.95013725 353.50 7.07555838e+00 4.34641011e-01 7.08889549e+00 0.06135142 0.96589234 353.75 6.66520703e+00 5.05289094e-01 6.68433256e+00 0.07566523 0.97018404 354.00 6.12005940e+00 7.78013353e-01 6.16931373e+00 0.12644688 0.97190922 354.25 5.58043246e+00 9.82147772e-01 5.66620161e+00 0.17421434 0.96489950 354.50 5.18702460e+00 9.67571923e-01 5.27649691e+00 0.18441748 0.97001171 354.75 4.99088958e+00 7.97784370e-01 5.05424957e+00 0.15850718 0.96006254 355.00 4.57493347e+00 7.03889855e-01 4.62876627e+00 0.15266085 0.95593102 355.25 4.17648245e+00 7.12879381e-01 4.23688596e+00 0.16905967 0.91827824 355.50 3.79358462e+00 5.33170625e-01 3.83086873e+00 0.13963075 0.91669737 355.75 3.43330385e+00 6.35428131e-01 3.49161055e+00 0.18300694 0.91153672 356.00 3.09194309e+00 8.33819582e-01 3.20240022e+00 0.26340884 0.91245127 356.25 2.87915318e+00 1.14245372e+00 3.09753507e+00 0.37774644 0.90739116 356.50 2.77378902e+00 1.12809520e+00 2.99441218e+00 0.38626738 0.94013771 356.75 2.63090842e+00 9.07432191e-01 2.78300419e+00 0.33213501 0.93087360 357.00 2.39034634e+00 8.35624992e-01 2.53219761e+00 0.33630348 0.92148624 357.25 2.02588217e+00 9.49434493e-01 2.23732528e+00 0.43825652 0.89959424 357.50 1.87888700e+00 1.06911450e+00 2.16176367e+00 0.51732461 0.91177476 357.75 1.41780639e+00 1.14556655e+00 1.82277198e+00 0.67959102 0.85887889 358.00 1.29671343e+00 1.14018435e+00 1.72669802e+00 0.72125336 0.85619044 358.25 1.14506267e+00 1.37091648e+00 1.78621961e+00 0.87492596 0.86799459 358.50 1.00505621e+00 1.44736113e+00 1.76209881e+00 0.96383462 0.86560858 358.75 6.43887548e-01 1.38900309e+00 1.53098686e+00 1.13672254 0.74724440 359.00 3.95402996e-01 1.73759880e+00 1.78201939e+00 1.34704931 0.75521086 359.25 2.24853816e-01 2.61817740e+00 2.62781509e+00 1.48512473 0.87521114 359.50 5.08975001e-01 2.81647981e+00 2.86209959e+00 1.39201268 0.87828788 359.75 1.41473303e+00 2.72158206e+00 3.06732431e+00 1.09141866 0.89287442 360.00 1.39191965e+00 2.32666400e+00 2.71123693e+00 1.03166683 0.89353409 360.25 1.25604584e+00 1.64179872e+00 2.06716090e+00 0.91773731 0.84982308 360.50 9.68582421e-01 1.55537240e+00 1.83230325e+00 1.01382855 0.82178458 360.75 3.04620399e-01 1.49625266e+00 1.52694650e+00 1.36995232 0.79357566 361.00 8.28398712e-02 1.52785116e+00 1.53009529e+00 1.51662951 0.77948966 361.25 -5.91804449e-01 1.60327541e+00 1.70901274e+00 1.92440387 0.75101334 361.50 -1.12392163e+00 1.66317335e+00 2.00732295e+00 2.16507436 0.68948312 361.75 -2.50046124e+00 2.04468874e+00 3.23002453e+00 2.45613707 0.71931959 362.00 -3.12693011e+00 2.01578818e+00 3.72036207e+00 2.56898475 0.55531614 362.25 -3.99627663e+00 3.95531718e+00 5.62270050e+00 2.36134554 0.29856470 362.50 -3.62150777e-01 5.84257059e+00 5.85378376e+00 1.63270196 0.15672746 362.75 8.08650628e+00 7.80070774e+00 1.12357743e+01 0.76741089 0.53560429 363.00 9.01457078e+00 7.49774706e+00 1.17251310e+01 0.69379511 0.71754670 363.25 1.15807660e+01 5.95910690e+00 1.30240199e+01 0.47523502 0.80559622 363.50 1.16762961e+01 2.16272100e+00 1.18749002e+01 0.18314758 0.78778593 363.75 1.07440203e+01 -7.37511621e-01 1.07693034e+01 -0.06853640 0.88584646 364.00 9.16677556e+00 -1.66717891e+00 9.31714869e+00 -0.17990550 0.89795726 364.25 8.68484191e+00 -2.14441262e+00 8.94566848e+00 -0.24207248 0.93010300 364.50 7.89185013e+00 -3.20996134e+00 8.51969191e+00 -0.38630647 0.91771952 364.75 7.35715784e+00 -4.37403987e+00 8.55920536e+00 -0.53638661 0.95671233 365.00 6.54072871e+00 -5.08374118e+00 8.28405435e+00 -0.66071041 0.95046121 365.25 6.06333612e+00 -5.55844646e+00 8.22559250e+00 -0.74198207 0.96448347 365.50 5.66660579e+00 -6.60587364e+00 8.70333199e+00 -0.86178373 0.94639922 365.75 4.98607541e+00 -7.92406324e+00 9.36225006e+00 -1.00915945 0.94760840 366.00 2.62327443e+00 -9.10154595e+00 9.47204875e+00 -1.29017888 0.90794332 366.25 6.04288475e-01 -9.61961817e+00 9.63857968e+00 -1.50806042 0.92813956 366.50 -2.46451168e+00 -8.38758858e+00 8.74216564e+00 -1.85658152 0.87107428 366.75 -4.19804937e+00 -6.85687040e+00 8.03991854e+00 -2.12016715 0.89043911 367.00 -5.04747106e+00 -4.01679539e+00 6.45070611e+00 -2.46941576 0.82758679 367.25 -4.49967109e+00 -2.37784381e+00 5.08932030e+00 -2.65544622 0.87707074 367.50 -3.66321023e+00 -1.48051295e+00 3.95107932e+00 -2.75750759 0.86678461 367.75 -3.19636963e+00 -1.04563883e+00 3.36305507e+00 -2.82543250 0.84729894 368.00 -2.53316879e+00 -5.95250612e-01 2.60216590e+00 -2.91079717 0.74199520 368.25 -2.15239835e+00 -4.24485875e-01 2.19385663e+00 -2.94687612 0.67327873 368.50 -1.68482306e+00 -4.87558555e-01 1.75395042e+00 -2.85990479 0.47860699 368.75 -1.13528720e+00 -6.03287458e-01 1.28562544e+00 -2.65314458 0.27753336 369.00 -2.08867948e-01 -1.34505931e+00 1.36117977e+00 -1.72485123 0.29803152 369.25 -2.26314848e-01 -1.99894603e+00 2.01171659e+00 -1.68353336 0.50544716 369.50 -6.46546748e-01 -3.31321568e+00 3.37571042e+00 -1.76351617 0.70322468 369.75 -1.68186783e+00 -4.01284912e+00 4.35105016e+00 -1.96767657 0.73220388 370.00 -3.70560360e+00 -4.48378028e+00 5.81685341e+00 -2.26145633 0.85622395 370.25 -4.36350595e+00 -3.60259150e+00 5.65852009e+00 -2.45142467 0.88684562 370.50 -5.07261286e+00 -2.39354596e+00 5.60896278e+00 -2.70071216 0.92592997 370.75 -5.29612907e+00 -1.94098097e+00 5.64060194e+00 -2.79030316 0.91506821 371.00 -5.83125768e+00 -7.48477013e-01 5.87909721e+00 -3.01393465 0.92195379 371.25 -5.63943980e+00 -1.62504738e-01 5.64178066e+00 -3.11278487 0.92148370 371.50 -5.26216587e+00 7.73885091e-01 5.31876751e+00 2.99557348 0.94415165 371.75 -5.06784018e+00 1.16456236e+00 5.19992400e+00 2.91571934 0.93202595 372.00 -4.33776226e+00 2.10906125e+00 4.82331015e+00 2.68903818 0.94105974 372.25 -3.73036739e+00 2.19359232e+00 4.32752679e+00 2.61001626 0.92369916 372.50 -2.31784507e+00 2.08109080e+00 3.11501921e+00 2.40996342 0.80018169 372.75 -1.38602489e+00 1.71528881e+00 2.20528472e+00 2.25042155 0.57438773 373.00 -3.63156697e-01 3.29804951e-02 3.64651203e-01 3.05102494 0.01378354 373.25 -4.03034258e-01 -2.51211258e+00 2.54423785e+00 -1.72987705 0.29452772 373.50 -2.92982956e+00 -5.23974948e+00 6.00323878e+00 -2.08064077 0.62266742 373.75 -5.70979881e+00 -4.65916035e+00 7.36950321e+00 -2.45717520 0.77532607 374.00 -7.12657101e+00 -2.92952515e+00 7.70520162e+00 -2.75157908 0.85646808 374.25 -7.60798062e+00 -4.55767097e-01 7.62162008e+00 -3.08175772 0.83378952 374.50 -8.32914352e+00 1.54505554e+00 8.47123536e+00 2.95817754 0.92824757 374.75 -7.70556433e+00 2.43671856e+00 8.08166561e+00 2.83531467 0.93890223 375.00 -7.15217691e+00 2.95795114e+00 7.73970991e+00 2.74943999 0.96274844 375.25 -6.78031620e+00 3.28007689e+00 7.53203771e+00 2.69101753 0.95460980 375.50 -6.40284562e+00 3.41284759e+00 7.25561580e+00 2.65187896 0.95800885 375.75 -5.88832541e+00 3.93465872e+00 7.08194290e+00 2.55251991 0.96013429 376.00 -5.45126681e+00 4.08029822e+00 6.80919550e+00 2.49904930 0.97114639 376.25 -5.32659352e+00 3.61426845e+00 6.43704396e+00 2.54541996 0.96609903 376.50 -5.32403715e+00 3.32606185e+00 6.27758385e+00 2.58319074 0.97457919 376.75 -5.55959191e+00 3.37274808e+00 6.50265268e+00 2.59629494 0.97170454 377.00 -5.89611753e+00 3.53399835e+00 6.87410694e+00 2.60163123 0.97986160 377.25 -6.25038905e+00 4.09869020e+00 7.47439795e+00 2.56118614 0.97574134 377.50 -6.27924479e+00 4.48023261e+00 7.71371501e+00 2.52186453 0.97459292 377.75 -6.02100648e+00 5.37847443e+00 8.07344451e+00 2.41249994 0.96346966 378.00 -5.76692320e+00 6.02219456e+00 8.33811912e+00 2.33454474 0.96734564 378.25 -5.15159320e+00 6.33908556e+00 8.16840977e+00 2.25321608 0.96548193 378.50 -4.72633651e+00 6.62299558e+00 8.13648126e+00 2.19060830 0.96190034 378.75 -4.02015552e+00 6.67710061e+00 7.79392860e+00 2.11274458 0.96692574 379.00 -3.71971820e+00 6.50450117e+00 7.49298599e+00 2.09027389 0.97018192 379.25 -3.29875820e+00 6.21335394e+00 7.03474042e+00 2.05886840 0.95970746 379.50 -3.18985060e+00 5.90526734e+00 6.71173071e+00 2.06606151 0.95195883 379.75 -3.36270977e+00 5.00324459e+00 6.02828943e+00 2.16255505 0.90079885 380.00 -3.98767148e+00 4.88051879e+00 6.30245885e+00 2.25585285 0.86142340 380.25 -4.38768304e+00 6.77682013e+00 8.07323068e+00 2.14538005 0.89509447 380.50 -3.89442041e+00 7.00170073e+00 8.01188638e+00 2.07839527 0.91827255 380.75 -3.60583005e+00 6.14805977e+00 7.12745742e+00 2.10122937 0.92654432 381.00 -3.96037995e+00 6.19612784e+00 7.35368001e+00 2.13952058 0.91403270 381.25 -4.34057263e+00 8.32170393e+00 9.38569801e+00 2.05157158 0.93386161 381.50 -3.64045816e+00 8.81450406e+00 9.53668797e+00 1.96246571 0.92473670 381.75 -1.92304380e+00 8.80212984e+00 9.00974956e+00 1.78589141 0.94458600 382.00 -1.28070535e+00 8.30760884e+00 8.40574629e+00 1.72375274 0.94057063 382.25 -3.81786892e-01 7.42596303e+00 7.43577085e+00 1.62216354 0.95629952 382.50 -3.49572562e-01 6.90461699e+00 6.91346055e+00 1.62138195 0.94107143 382.75 -8.64185687e-01 6.24902139e+00 6.30849311e+00 1.70821609 0.94641441 383.00 -1.02136887e+00 6.10294134e+00 6.18781766e+00 1.73661643 0.95300735 383.25 -1.32567733e+00 5.53679005e+00 5.69328240e+00 1.80580291 0.93796463 383.50 -1.67406360e+00 5.19623963e+00 5.45924860e+00 1.88246491 0.91500298 383.75 -2.12376799e+00 4.92077814e+00 5.35951938e+00 1.97823710 0.95442349 384.00 -2.61474895e+00 4.77462293e+00 5.44370611e+00 2.07182171 0.93550951 384.25 -3.60675122e+00 4.50881285e+00 5.77391095e+00 2.24549682 0.93896410 384.50 -4.06284610e+00 4.30718640e+00 5.92102804e+00 2.32701050 0.90633113 384.75 -4.99492870e+00 4.04036635e+00 6.42447452e+00 2.46145220 0.90410433 385.00 -5.77781548e+00 3.86668721e+00 6.95229615e+00 2.55181756 0.88917409 385.25 -6.75910440e+00 3.83000795e+00 7.76881286e+00 2.62606058 0.90062561 385.50 -7.53568970e+00 3.16387886e+00 8.17292779e+00 2.74408997 0.82880150 385.75 -8.89410660e+00 1.25150171e+00 8.98172526e+00 3.00179911 0.81649818 386.00 -1.08060905e+01 -1.39579527e+00 1.08958633e+01 -3.01313644 0.77921443 386.25 -1.37222113e+01 -2.68847413e+00 1.39830961e+01 -2.94812193 0.81295323 386.50 -1.39346334e+01 -2.27748838e+00 1.41195241e+01 -2.97958424 0.69347660 386.75 -1.56034179e+01 -3.94076928e+00 1.60933624e+01 -2.89420784 0.75163682 387.00 -1.20631705e+01 -5.86049796e+00 1.34113951e+01 -2.68935538 0.70733720 387.25 -9.26286541e+00 -8.15773017e+00 1.23429833e+01 -2.41954802 0.74199977 387.50 -5.47604052e+00 -7.43603407e+00 9.23480495e+00 -2.20554911 0.68239741 387.75 -3.21210613e+00 -7.16831641e+00 7.85508663e+00 -1.99206718 0.73389981 388.00 8.49192954e-01 -5.93746815e+00 5.99788769e+00 -1.42873699 0.73466861 388.25 2.11912584e+00 -5.43518015e+00 5.83368473e+00 -1.19903518 0.88001846 388.50 3.67900852e+00 -4.85570073e+00 6.09203851e+00 -0.92240581 0.89976677 388.75 4.30364843e+00 -4.38760356e+00 6.14592993e+00 -0.79505759 0.91304570 389.00 5.12095530e+00 -3.62211372e+00 6.27247088e+00 -0.61561658 0.91086555 389.25 5.27227881e+00 -3.33121706e+00 6.23649990e+00 -0.56350020 0.92374652 389.50 5.51505624e+00 -3.02406732e+00 6.28973994e+00 -0.50155967 0.93572846 389.75 5.62032060e+00 -2.79969251e+00 6.27903510e+00 -0.46215651 0.94442860 390.00 5.19682148e+00 -2.56004469e+00 5.79316686e+00 -0.45772411 0.95597197 390.25 5.37168457e+00 -2.29095509e+00 5.83981766e+00 -0.40312970 0.96163393 390.50 5.25124849e+00 -2.04812704e+00 5.63652687e+00 -0.37187924 0.96561443 390.75 5.14479718e+00 -2.01582880e+00 5.52562248e+00 -0.37343388 0.97276848 391.00 4.89524521e+00 -2.02780180e+00 5.29862301e+00 -0.39272085 0.97701422 391.25 4.71834215e+00 -1.98841805e+00 5.12021084e+00 -0.39883703 0.96997627 391.50 4.19752644e+00 -1.59536586e+00 4.49048110e+00 -0.36321067 0.95220390 391.75 4.28616914e+00 -1.20799857e+00 4.45314568e+00 -0.27471080 0.95831487 392.00 4.69945446e+00 -1.11203128e+00 4.82923243e+00 -0.23235597 0.98174325 392.25 4.71312623e+00 -1.17941830e+00 4.85845514e+00 -0.24520565 0.98043116 392.50 4.59541667e+00 -1.21680729e+00 4.75378526e+00 -0.25884684 0.98597381 392.75 4.50834444e+00 -1.18495126e+00 4.66146748e+00 -0.25702182 0.98209050 393.00 4.22123127e+00 -1.22888139e+00 4.39646937e+00 -0.28328947 0.98282378 393.25 4.08671635e+00 -1.20407252e+00 4.26040387e+00 -0.28652368 0.98733870 393.50 4.01770392e+00 -1.18455186e+00 4.18868809e+00 -0.28670975 0.98476849 393.75 3.87484626e+00 -1.13204673e+00 4.03682590e+00 -0.28424196 0.97853398 394.00 3.64456790e+00 -1.04414819e+00 3.79118987e+00 -0.27902072 0.97356166 394.25 3.48261108e+00 -9.43137419e-01 3.60805877e+00 -0.26446972 0.95998657 394.50 3.32060451e+00 -8.24778204e-01 3.42150163e+00 -0.24345521 0.95832383 394.75 3.19840535e+00 -6.65812774e-01 3.26697160e+00 -0.20523906 0.94608414 395.00 3.08037341e+00 -3.36046233e-01 3.09864929e+00 -0.10866298 0.93900992 395.25 3.01250742e+00 -1.07375828e-01 3.01442043e+00 -0.03562826 0.86847697 395.50 3.07785457e+00 4.64702979e-01 3.11273796e+00 0.14985094 0.83925207 395.75 3.47177058e+00 8.24120117e-01 3.56824395e+00 0.23306381 0.82352338 396.00 3.98263824e+00 7.05392267e-01 4.04462428e+00 0.17529886 0.83086725 396.25 4.14736345e+00 5.75132467e-01 4.18705158e+00 0.13779543 0.81738926 396.50 4.44503081e+00 2.44577940e-01 4.45175441e+00 0.05496735 0.86860315 396.75 4.76771451e+00 -1.10896605e-01 4.76900406e+00 -0.02325572 0.90006144 397.00 5.08025616e+00 -2.42005902e-01 5.08601705e+00 -0.04760057 0.92471573 397.25 4.73812703e+00 -8.58559465e-01 4.81528526e+00 -0.17925725 0.90735791 397.50 4.57562298e+00 -1.24728066e+00 4.74257679e+00 -0.26612663 0.91321190 397.75 3.59198452e+00 -1.19538111e+00 3.78566887e+00 -0.32126262 0.86488636 398.00 3.21255920e+00 -9.17621132e-01 3.34104252e+00 -0.27822687 0.86942915 398.25 2.98163844e+00 -4.33392293e-01 3.01297140e+00 -0.14434286 0.82753579 398.50 2.82756551e+00 -1.19032601e-03 2.82756577e+00 -0.00042097 0.78559237 398.75 2.71159527e+00 7.17682984e-01 2.80496306e+00 0.25873910 0.71999981 399.00 2.62429207e+00 1.31599953e+00 2.93577309e+00 0.46482163 0.70933343 399.25 2.02808151e+00 2.14965716e+00 2.95535794e+00 0.81449078 0.34315073 399.50 4.81400175e-01 2.45919714e+00 2.50587245e+00 1.37748579 0.16538294 399.75 -3.91488889e-01 1.18137357e+00 1.24455095e+00 1.89079191 0.02992918 400.00 -1.01008621e+00 -5.98427263e-01 1.17404827e+00 -2.60674188 0.02178954 400.25 -1.12178280e+00 -3.52603564e+00 3.70017891e+00 -1.87881366 0.24483594 400.50 -1.14632362e+00 -3.93360766e+00 4.09723408e+00 -1.85436114 0.45927836 400.75 -4.51593422e-01 -3.32430021e+00 3.35483360e+00 -1.70581598 0.71560866 401.00 5.12760906e-02 -2.94604613e+00 2.94649233e+00 -1.55339303 0.79391678 401.25 9.54179553e-01 -2.66671839e+00 2.83228628e+00 -1.22718049 0.85452399 401.50 1.18296909e+00 -2.52707483e+00 2.79025501e+00 -1.13297808 0.85697345 401.75 1.44679162e+00 -2.59876180e+00 2.97435184e+00 -1.06280582 0.86632382 402.00 1.51328216e+00 -2.44409175e+00 2.87464908e+00 -1.01640809 0.84632455 402.25 1.79468846e+00 -2.39230857e+00 2.99065995e+00 -0.92717296 0.91648407 402.50 1.77243322e+00 -2.47593232e+00 3.04495654e+00 -0.94950190 0.91954015 402.75 1.83071523e+00 -2.34843215e+00 2.97769236e+00 -0.90865121 0.88614721 403.00 1.81456990e+00 -2.29375782e+00 2.92472030e+00 -0.90151170 0.85595242 403.25 1.64160110e+00 -2.02615214e+00 2.60770908e+00 -0.88986298 0.80444098 403.50 1.57129642e+00 -1.93415135e+00 2.49196988e+00 -0.88854254 0.69982433 403.75 1.51264021e+00 -1.70132029e+00 2.27652611e+00 -0.84403727 0.56940792 404.00 1.13486463e+00 -1.16687490e+00 1.62773301e+00 -0.79930426 0.25832279 404.25 1.68979002e-01 -1.94086052e-01 2.57338879e-01 -0.85444128 0.00633256 404.50 1.02409338e-01 -4.88982692e-01 4.99591579e-01 -1.36434680 0.03433235 404.75 2.99301337e-01 -1.08831243e+00 1.12871840e+00 -1.30241694 0.23874614 405.00 1.30817592e-01 -9.75217332e-01 9.83952279e-01 -1.43745035 0.23810408 405.25 -2.05488959e-01 -8.64904334e-01 8.88979876e-01 -1.80405731 0.32474843 405.50 -3.09963665e-01 -4.29824001e-01 5.29930321e-01 -2.19557035 0.12038500 405.75 -2.64379280e-01 -8.04950722e-02 2.76361829e-01 -2.84604169 0.07033638 406.00 5.09866476e-03 -1.12131691e-02 1.23179359e-02 -1.14403804 0.00016099 406.25 7.85084837e-02 -7.41984355e-02 1.08023099e-01 -0.75718134 0.01734453 406.50 1.36752782e-01 -2.98221160e-01 3.28081063e-01 -1.14084540 0.11410889 406.75 1.93087827e-02 -5.40794646e-01 5.41139242e-01 -1.53510702 0.28415500 407.00 -2.65547646e-01 -6.33326923e-01 6.86744890e-01 -1.96782063 0.17318029 407.25 -8.04907932e-01 -2.08545192e-01 8.31485343e-01 -2.88807530 0.16090571 407.50 -1.51286615e+00 6.29906234e-01 1.63876351e+00 2.74705763 0.36836543 407.75 -1.85683658e+00 1.23092334e+00 2.22778239e+00 2.55619241 0.52550527 408.00 -1.04485837e+00 2.07551265e+00 2.32367850e+00 2.03717765 0.33977395 408.25 -6.32195925e-01 2.28947750e+00 2.37515871e+00 1.84021380 0.29167832 408.50 -1.18204913e+00 2.20420345e+00 2.50115033e+00 2.06303753 0.27757832 408.75 -1.42812810e+00 2.53165443e+00 2.90668609e+00 2.08440693 0.45977910 409.00 -1.04190420e+00 3.69457610e+00 3.83867906e+00 1.84566712 0.63392852 409.25 -1.06982703e+00 4.19862486e+00 4.33277977e+00 1.82029140 0.71073777 409.50 -9.36600887e-01 4.53424230e+00 4.62996485e+00 1.77449320 0.61313201 409.75 -7.37068200e-01 5.02769789e+00 5.08143834e+00 1.71636094 0.61112241 410.00 -1.91344085e-01 6.55960298e+00 6.56239315e+00 1.59995813 0.77150426 410.25 1.90771186e-01 7.35101031e+00 7.35348531e+00 1.54485045 0.79693624 410.50 2.01914890e+00 8.62769816e+00 8.86082038e+00 1.34090284 0.79729425 410.75 3.15426775e+00 8.78623411e+00 9.33527261e+00 1.22612532 0.79528764 411.00 5.13269938e+00 8.37689428e+00 9.82430459e+00 1.02107559 0.82826233 411.25 6.14439790e+00 7.70867678e+00 9.85785592e+00 0.89784112 0.84451944 411.50 7.42404699e+00 6.73232263e+00 1.00220079e+01 0.73657388 0.85754571 411.75 7.83301514e+00 6.55897345e+00 1.02164700e+01 0.69710396 0.84534899 412.00 9.26180803e+00 6.29820285e+00 1.12003771e+01 0.59718946 0.88191776 412.25 9.42743158e+00 6.39765995e+00 1.13932664e+01 0.59623358 0.88135540 412.50 1.05760089e+01 5.51537980e+00 1.19277567e+01 0.48069864 0.89894661 412.75 1.07683683e+01 4.87733759e+00 1.18214288e+01 0.42528942 0.89598025 413.00 1.08846444e+01 2.88664769e+00 1.12609155e+01 0.25923603 0.90257595 413.25 1.11444278e+01 2.11174868e+00 1.13427401e+01 0.18726890 0.92461368 413.50 1.09802707e+01 1.36624975e+00 1.10649438e+01 0.12379145 0.94705595 413.75 1.07678621e+01 1.06328773e+00 1.08202327e+01 0.09842732 0.95151615 414.00 1.09454096e+01 4.80102075e-01 1.09559340e+01 0.04383523 0.96835406 414.25 1.11005020e+01 3.82844935e-01 1.11071020e+01 0.03447531 0.96187946 414.50 1.14436771e+01 6.81901974e-01 1.14639756e+01 0.05951729 0.96980803 414.75 1.12456937e+01 3.63049917e-01 1.12515525e+01 0.03227225 0.96498357 415.00 1.07671563e+01 -7.45294218e-02 1.07674143e+01 -0.00692181 0.96656105 415.25 1.08122994e+01 -5.92019254e-01 1.08284950e+01 -0.05469962 0.96594626 415.50 1.10594426e+01 -1.38318064e+00 1.11456027e+01 -0.12442179 0.97296679 415.75 1.11845942e+01 -1.60576844e+00 1.12992760e+01 -0.14259526 0.97053522 416.00 1.11846756e+01 -1.81476322e+00 1.13309459e+01 -0.16085265 0.96341738 416.25 1.06491339e+01 -2.40048998e+00 1.09163366e+01 -0.22171079 0.95172164 416.50 1.01675499e+01 -2.39882234e+00 1.04466942e+01 -0.23169239 0.95764454 416.75 9.55611449e+00 -2.25427805e+00 9.81840586e+00 -0.23166376 0.95841736 417.00 9.37864373e+00 -2.10658215e+00 9.61231744e+00 -0.22094777 0.95333015 417.25 9.43703066e+00 -1.73753270e+00 9.59565358e+00 -0.18207938 0.94945120 417.50 9.46724207e+00 -1.56075425e+00 9.59503133e+00 -0.16338875 0.95612619 417.75 9.83906223e+00 -1.61101938e+00 9.97008170e+00 -0.16229693 0.96594906 418.00 9.98055430e+00 -1.87342271e+00 1.01548598e+01 -0.18554818 0.96677418 418.25 9.97140479e+00 -2.14020519e+00 1.01984995e+01 -0.21142656 0.95403080 418.50 1.01084784e+01 -2.42364008e+00 1.03949684e+01 -0.23532097 0.95468523 418.75 9.91696701e+00 -2.33943298e+00 1.01891698e+01 -0.23166664 0.94488068 419.00 9.98118477e+00 -2.39044322e+00 1.02634433e+01 -0.23506737 0.96258198 419.25 9.53895935e+00 -2.20228136e+00 9.78988195e+00 -0.22689669 0.96206980 419.50 9.50723635e+00 -2.16640326e+00 9.75094078e+00 -0.22404340 0.96003179 419.75 9.81991914e+00 -1.98976795e+00 1.00194805e+01 -0.19991899 0.94756856 420.00 1.02482637e+01 -1.61748138e+00 1.03751219e+01 -0.15653852 0.96095653 420.25 1.03248133e+01 -1.19130924e+00 1.03933145e+01 -0.11487514 0.95883520 420.50 1.02911749e+01 -1.25905258e+00 1.03679070e+01 -0.12173796 0.95745709 420.75 1.09063412e+01 -1.91461718e+00 1.10731223e+01 -0.17378007 0.91875930 421.00 1.11040792e+01 -2.17042649e+00 1.13142090e+01 -0.19302840 0.91328439 421.25 1.12658513e+01 -2.20446592e+00 1.14795068e+01 -0.19323522 0.93677712 421.50 1.14615581e+01 -2.18501944e+00 1.16679743e+01 -0.18837857 0.93281860 421.75 1.14930415e+01 -3.40588465e+00 1.19870786e+01 -0.28809856 0.92546936 422.00 1.09078933e+01 -3.97110814e+00 1.16082659e+01 -0.34914353 0.92847028 422.25 1.03457276e+01 -3.87940274e+00 1.10491559e+01 -0.35874990 0.94510913 422.50 9.67300895e+00 -3.55973793e+00 1.03072225e+01 -0.35262604 0.94229718 422.75 9.27139096e+00 -1.61119748e+00 9.41034790e+00 -0.17206326 0.91645508 423.00 9.71796701e+00 -2.85307694e-01 9.72215425e+00 -0.02935035 0.91968964 423.25 1.14162866e+01 2.38368574e-01 1.14187749e+01 0.02087666 0.95503373 423.50 1.17208587e+01 2.31347811e-01 1.17231417e+01 0.01973557 0.95394900 423.75 1.17421188e+01 9.18678989e-01 1.17780017e+01 0.07807887 0.95594437 424.00 1.21064751e+01 1.44526803e+00 1.21924378e+01 0.11881744 0.94982612 424.25 1.26433154e+01 1.86945982e+00 1.27807787e+01 0.14679787 0.93943186 424.50 1.34457797e+01 2.22310918e+00 1.36283236e+01 0.16385643 0.92929124 424.75 1.40829612e+01 3.10129756e+00 1.44203967e+01 0.21675661 0.94848186 425.00 1.47554197e+01 3.63733731e+00 1.51971258e+01 0.24168992 0.94974396 425.25 1.60812235e+01 4.49702048e+00 1.66981718e+01 0.27267872 0.95744127 425.50 1.69189254e+01 4.89379633e+00 1.76124751e+01 0.28156531 0.93733237 425.75 1.85564399e+01 6.27423522e+00 1.95884530e+01 0.32604905 0.91878025 426.00 1.99324472e+01 6.00808705e+00 2.08182507e+01 0.29276128 0.92353253 426.25 2.18549770e+01 5.17953638e+00 2.24603565e+01 0.23270241 0.93099231 426.50 2.26814929e+01 4.55279582e+00 2.31339160e+01 0.19809483 0.91338910 426.75 2.39784538e+01 3.81128177e+00 2.42794587e+01 0.15762750 0.92906900 427.00 2.33980531e+01 3.83211403e+00 2.37097867e+01 0.16233793 0.87712665 427.25 2.43777586e+01 4.07963373e+00 2.47167661e+01 0.16581410 0.90418747 427.50 2.49688379e+01 2.41151531e+00 2.50850208e+01 0.09628237 0.88093178 427.75 2.70213010e+01 1.10545602e+00 2.70439039e+01 0.04088774 0.90139492 428.00 2.73365726e+01 8.36184559e-01 2.73493584e+01 0.03057896 0.89281360 428.25 2.81384557e+01 9.05331542e-01 2.81530161e+01 0.03216308 0.89845404 428.50 2.53951969e+01 4.10198226e-01 2.53985095e+01 0.01615119 0.82837112 428.75 2.84675084e+01 -6.19654343e-02 2.84675759e+01 -0.00217670 0.86409123 429.00 2.76771785e+01 6.89311551e-01 2.76857610e+01 0.02490027 0.82136958 429.25 3.00135836e+01 -1.31149354e+00 3.00422239e+01 -0.04366889 0.86429828 429.50 2.98933249e+01 -1.39665091e+00 2.99259337e+01 -0.04668721 0.86497776 429.75 2.87356743e+01 -1.04829085e+00 2.87547890e+01 -0.03646430 0.88316980 430.00 2.61739672e+01 -6.84161649e-01 2.61829073e+01 -0.02613306 0.86348766 430.25 2.57224914e+01 -1.06116715e+00 2.57443710e+01 -0.04123107 0.85669388 430.50 2.55685188e+01 -1.12996195e+00 2.55934751e+01 -0.04416475 0.88705757 430.75 2.58326141e+01 -2.31178947e-01 2.58336485e+01 -0.00894887 0.90221386 431.00 2.37710970e+01 -6.81375915e-02 2.37711946e+01 -0.00286640 0.91294354 431.25 2.28130277e+01 7.99227838e-01 2.28270234e+01 0.03501951 0.92453806 431.50 2.29917465e+01 3.75900723e+00 2.32970071e+01 0.16205995 0.91037202 431.75 2.31750176e+01 4.83224399e+00 2.36734455e+01 0.20556557 0.92601647 432.00 2.27098782e+01 4.35429946e+00 2.31235484e+01 0.18943685 0.93894845 432.25 2.19158287e+01 5.27851350e+00 2.25425431e+01 0.23635225 0.93655812 432.50 2.03935740e+01 7.96520964e+00 2.18938902e+01 0.37235462 0.94804049 432.75 1.96261238e+01 9.21538809e+00 2.16819766e+01 0.43898981 0.94339483 433.00 2.04186478e+01 1.20051143e+01 2.36863663e+01 0.53151101 0.96276143 433.25 2.09904460e+01 1.23466497e+01 2.43523835e+01 0.53170030 0.96425170 433.50 2.09411875e+01 1.11788360e+01 2.37381489e+01 0.49033656 0.96878921 433.75 2.04830168e+01 1.11169413e+01 2.33053719e+01 0.49725181 0.96339581 434.00 1.94660905e+01 1.11106642e+01 2.24137355e+01 0.51864965 0.96219586 434.25 1.99932778e+01 1.06069748e+01 2.26326992e+01 0.48776996 0.95542080 434.50 2.10802053e+01 8.53012181e+00 2.27406692e+01 0.38450924 0.94527950 434.75 2.00182635e+01 6.89826795e+00 2.11734970e+01 0.33185491 0.94186813 435.00 1.83035952e+01 6.69943137e+00 1.94911257e+01 0.35087221 0.95688918 435.25 1.67124939e+01 5.70906880e+00 1.76607169e+01 0.32917635 0.93493348 435.50 1.46161534e+01 3.79559115e+00 1.51009421e+01 0.25407268 0.93575720 435.75 1.25909261e+01 3.47441433e+00 1.30615074e+01 0.26924539 0.92600635 436.00 9.56729712e+00 2.69364747e+00 9.93926108e+00 0.27444301 0.93949014 436.25 7.53417792e+00 2.96586388e+00 8.09692444e+00 0.37502427 0.91431462 436.50 6.09060749e+00 3.53825227e+00 7.04377234e+00 0.52628379 0.94753791 436.75 5.03202780e+00 4.33794676e+00 6.64372531e+00 0.71145819 0.93264297 437.00 3.94733190e+00 5.23625345e+00 6.55742170e+00 0.92483793 0.95136091 437.25 2.89820647e+00 5.79325157e+00 6.47775922e+00 1.10693046 0.92936620 437.50 2.15048248e+00 6.39749011e+00 6.74925586e+00 1.24651767 0.95860528 437.75 1.72761489e+00 6.98422387e+00 7.19472281e+00 1.32830428 0.96039614 438.00 1.65009269e+00 7.33178902e+00 7.51518038e+00 1.34942474 0.97098062 438.25 1.45960795e+00 7.62138598e+00 7.75989560e+00 1.38157280 0.96063264 438.50 1.23493648e+00 7.55260107e+00 7.65289821e+00 1.40871919 0.96424354 438.75 1.08218975e+00 7.48267468e+00 7.56052611e+00 1.42716617 0.95480511 439.00 7.24430880e-01 7.49407384e+00 7.52900677e+00 1.47442859 0.96433742 439.25 5.06762284e-01 7.42727304e+00 7.44454114e+00 1.50267198 0.96892356 439.50 3.12374036e-01 7.35311939e+00 7.35975151e+00 1.52834002 0.97897999 439.75 1.49640823e-01 7.44201324e+00 7.44351755e+00 1.55069146 0.97301615 440.00 1.50658875e-02 7.61240064e+00 7.61241555e+00 1.56881721 0.97549019 440.25 -1.04756226e-01 7.21063726e+00 7.21139817e+00 1.58532332 0.95379573 440.50 -2.15987606e-01 6.88384428e+00 6.88723187e+00 1.60216205 0.94956817 440.75 -7.02248448e-01 6.97171783e+00 7.00699667e+00 1.67118590 0.95734450 441.00 -1.01620863e+00 7.03548466e+00 7.10849663e+00 1.71424469 0.96299054 441.25 -1.71035997e+00 6.86918844e+00 7.07891807e+00 1.81482428 0.95575857 441.50 -1.91122533e+00 7.02379770e+00 7.27918377e+00 1.83647106 0.95374761 441.75 -2.08301963e+00 7.28457904e+00 7.57654687e+00 1.84931317 0.93847905 442.00 -1.91644064e+00 7.39933662e+00 7.64348920e+00 1.82422905 0.94051964 442.25 -1.70467788e+00 7.59932116e+00 7.78817108e+00 1.79146321 0.95567941 442.50 -1.96743066e+00 7.60091200e+00 7.85141048e+00 1.82407884 0.95403765 442.75 -1.90513174e+00 8.09064815e+00 8.31192604e+00 1.80205678 0.94323989 443.00 -1.56442151e+00 8.60927354e+00 8.75025745e+00 1.75054853 0.95939239 443.25 -7.59789606e-01 8.86649741e+00 8.89899189e+00 1.65627969 0.96310876 443.50 -3.39947483e-01 8.75497168e+00 8.76156912e+00 1.60960591 0.95878895 443.75 2.35939629e-01 8.19991618e+00 8.20330987e+00 1.54203084 0.94753239 444.00 6.24428327e-01 7.67543577e+00 7.70079379e+00 1.48962098 0.94958750 444.25 8.86370138e-01 6.90130728e+00 6.95799498e+00 1.44306052 0.94131081 444.50 6.52657006e-01 6.03337262e+00 6.06857037e+00 1.46304084 0.91314688 444.75 -2.78764705e-01 5.54604885e+00 5.55305029e+00 1.62101772 0.91414766 445.00 -7.15344944e-01 5.50768608e+00 5.55394673e+00 1.69995452 0.89134702 445.25 -1.27928750e+00 5.93519556e+00 6.07150088e+00 1.78309106 0.89880614 445.50 -1.62503146e+00 6.36753449e+00 6.57162253e+00 1.82066849 0.91805322 445.75 -1.76395281e+00 7.13803671e+00 7.35276122e+00 1.81306273 0.92205818 446.00 -1.61877695e+00 7.90472045e+00 8.06876968e+00 1.77278965 0.90914479 446.25 -5.38774180e-01 8.46082753e+00 8.47796439e+00 1.63438913 0.91173781 446.50 2.98848854e-01 8.51339132e+00 8.51863500e+00 1.53570735 0.89505117 446.75 1.86537346e+00 8.52910454e+00 8.73070687e+00 1.35547982 0.86273551 447.00 3.24369679e+00 7.93756929e+00 8.57476385e+00 1.18285438 0.87983848 447.25 4.23564807e+00 7.18837595e+00 8.34346831e+00 1.03832932 0.91678148 447.50 4.11762239e+00 5.42808008e+00 6.81313933e+00 0.92182783 0.85651801 447.75 4.00105007e+00 3.89205537e+00 5.58180049e+00 0.77159019 0.89978414 448.00 3.53484080e+00 2.85749375e+00 4.54536798e+00 0.67982971 0.86574666 448.25 3.19987912e+00 2.06560380e+00 3.80866714e+00 0.57322332 0.86308328 448.50 1.86364731e+00 1.43755361e+00 2.35366558e+00 0.65703552 0.68374949 448.75 1.38228485e+00 1.31078674e+00 1.90496018e+00 0.75885549 0.71311988 449.00 7.77226719e-01 1.51273453e+00 1.70071959e+00 1.09617828 0.57322960 449.25 4.91490538e-01 1.52766427e+00 1.60478069e+00 1.25952777 0.62642072 449.50 3.72513972e-01 1.58939340e+00 1.63246380e+00 1.34057680 0.54354421 449.75 4.58219525e-01 1.59337722e+00 1.65795539e+00 1.29077487 0.52371320 450.00 3.95388520e-01 1.29276836e+00 1.35188096e+00 1.27398455 0.33285762 450.25 4.90385113e-01 7.68899749e-01 9.11967314e-01 1.00306312 0.17447432 450.50 1.50926829e-01 3.45122811e-01 3.76681115e-01 1.15854252 0.04108626 450.75 -1.89785277e-01 3.97866465e-01 4.40813084e-01 2.01588131 0.08453905 451.00 -9.46217420e-01 5.90339572e-02 9.48057179e-01 3.07928399 0.21586408 451.25 -1.68889273e+00 1.45608942e-01 1.69515800e+00 3.05558970 0.46592275 451.50 -2.63669502e+00 5.65328115e-01 2.69661946e+00 2.93038255 0.70445727 451.75 -3.04799359e+00 8.74233002e-01 3.17089077e+00 2.86226876 0.82402465 452.00 -2.94084349e+00 1.92247524e+00 3.51347000e+00 2.56260985 0.87145607 452.25 -2.57735465e+00 2.27748797e+00 3.43943432e+00 2.41788263 0.89411815 452.50 -2.28301558e+00 2.49056552e+00 3.37862054e+00 2.31274298 0.92913606 452.75 -2.09321489e+00 2.56038523e+00 3.30713186e+00 2.25614069 0.93247212 453.00 -1.42146907e+00 2.61999031e+00 2.98075889e+00 2.06789981 0.91387873 453.25 -1.24346051e+00 2.55059283e+00 2.83755490e+00 2.02440876 0.92861233 453.50 -1.25370146e+00 2.33601595e+00 2.65117670e+00 2.06335836 0.91420151 453.75 -1.16805338e+00 2.14862663e+00 2.44559709e+00 2.06873417 0.90309338 454.00 -1.05351676e+00 1.86066288e+00 2.13821513e+00 2.08599587 0.89987992 454.25 -9.62725176e-01 1.77999964e+00 2.02366956e+00 2.06659283 0.90542700 454.50 -7.65799565e-01 1.71799362e+00 1.88094419e+00 1.99011223 0.91435569 454.75 -7.14916499e-01 1.67586269e+00 1.82198281e+00 1.97401811 0.91125138 455.00 -6.41313310e-01 1.72939821e+00 1.84447850e+00 1.92590639 0.91204922 455.25 -4.31419717e-01 1.51079957e+00 1.57119010e+00 1.84895076 0.82587718 455.50 -2.64920939e-01 1.13065330e+00 1.16127515e+00 1.80095226 0.80154970 455.75 -2.66768749e-01 8.14905129e-01 8.57458999e-01 1.88716284 0.57716615 456.00 -4.95660626e-02 2.64483481e-01 2.69087916e-01 1.75605446 0.14288530 456.25 -1.14171730e-01 -1.57314634e-02 1.15250435e-01 -3.00466711 0.02070775 456.50 -2.97389716e-01 -5.56633099e-01 6.31095120e-01 -2.06147891 0.32635019 456.75 -4.90942402e-01 -9.10166284e-01 1.03413109e+00 -2.06546383 0.49736557 457.00 -8.26053885e-01 -1.13469589e+00 1.40353118e+00 -2.20006541 0.60451577 457.25 -1.56091525e+00 -1.53574724e+00 2.18974336e+00 -2.36432177 0.72157459 457.50 -2.22449727e+00 -1.85640513e+00 2.89734846e+00 -2.44614978 0.86172054 457.75 -2.64422567e+00 -1.70965335e+00 3.14878452e+00 -2.56763877 0.81861265 458.00 -3.30019633e+00 -1.32392946e+00 3.55585222e+00 -2.76008075 0.84367054 458.25 -3.48217141e+00 -2.82637447e-01 3.49362300e+00 -3.06060319 0.85082927 458.50 -3.63046194e+00 4.55952533e-01 3.65898163e+00 3.01665601 0.89637544 458.75 -3.32181217e+00 9.25690286e-01 3.44838203e+00 2.86981744 0.83970147 459.00 -2.85401120e+00 1.49277948e+00 3.22083382e+00 2.65967859 0.82048729 459.25 -1.94389145e+00 1.46700377e+00 2.43532627e+00 2.49510708 0.75750609 459.50 -1.32060218e+00 1.28996607e+00 1.84607762e+00 2.36792937 0.71038084 459.75 -8.51764926e-01 8.57326171e-01 1.20851630e+00 2.35294058 0.38681911 460.00 -5.20002480e-01 4.36680165e-01 6.79037661e-01 2.44307031 0.20383889 460.25 -3.61962860e-01 -2.01499612e-01 4.14269485e-01 -2.63363083 0.07505801 460.50 -5.30774434e-01 -5.64195055e-01 7.74620914e-01 -2.32568200 0.23594895 460.75 -3.29359666e-01 -8.54524425e-01 9.15800078e-01 -1.93867993 0.26229617 461.00 5.66056361e-02 -1.23333228e+00 1.23463059e+00 -1.52493201 0.42602301 461.25 1.49472381e-01 -1.88100595e+00 1.88693544e+00 -1.49149889 0.56166489 461.50 3.86103379e-01 -2.23414127e+00 2.26725892e+00 -1.39966706 0.62460907 461.75 2.97843628e-01 -3.11806069e+00 3.13225370e+00 -1.47556320 0.69753108 462.00 5.38945491e-01 -3.55352967e+00 3.59416685e+00 -1.42027858 0.76765763 462.25 2.49940941e-01 -4.31292076e+00 4.32015694e+00 -1.51290941 0.77993820 462.50 -1.48361667e-01 -5.42084323e+00 5.42287309e+00 -1.59815824 0.82570534 462.75 -8.89331690e-01 -6.51773946e+00 6.57813337e+00 -1.70640674 0.85908579 463.00 -1.40234234e+00 -7.57930732e+00 7.70794807e+00 -1.75374984 0.87903479 463.25 -3.19537942e+00 -9.40439016e+00 9.93242185e+00 -1.89833340 0.87660225 463.50 -5.06109375e+00 -9.57713637e+00 1.08321840e+01 -2.05694862 0.87895979 463.75 -7.39934764e+00 -8.23718326e+00 1.10725577e+01 -2.30266374 0.88586640 464.00 -7.94779811e+00 -7.36431084e+00 1.08351543e+01 -2.39428233 0.90096182 464.25 -7.93330926e+00 -6.69807874e+00 1.03827576e+01 -2.44041811 0.91516455 464.50 -7.86791595e+00 -6.50950883e+00 1.02116505e+01 -2.45039679 0.91014676 464.75 -7.90642064e+00 -5.17067903e+00 9.44708468e+00 -2.56242126 0.89693968 465.00 -8.20624885e+00 -5.08529404e+00 9.65415639e+00 -2.58682408 0.91322584 465.25 -8.59011554e+00 -4.84874357e+00 9.86409646e+00 -2.62771846 0.95388910 465.50 -8.41139682e+00 -4.75531269e+00 9.66253565e+00 -2.62704720 0.94939039 465.75 -8.17075244e+00 -4.39264701e+00 9.27666660e+00 -2.64831462 0.93397762 466.00 -8.06471848e+00 -4.52331794e+00 9.24662584e+00 -2.63043668 0.89812215 466.25 -7.17536295e+00 -5.00580372e+00 8.74893733e+00 -2.53245388 0.90109833 466.50 -7.08552963e+00 -5.56253421e+00 9.00813616e+00 -2.47603085 0.86965789 466.75 -7.06920754e+00 -7.50678905e+00 1.03114294e+01 -2.32618281 0.87697355 467.00 -7.35169975e+00 -9.94396529e+00 1.23664843e+01 -2.20742240 0.89932079 467.25 -7.97617495e+00 -1.22765310e+01 1.46401018e+01 -2.14696708 0.93752646 467.50 -9.60495883e+00 -1.42817283e+01 1.72111300e+01 -2.16285047 0.91363300 467.75 -1.35770919e+01 -1.60948698e+01 2.10566441e+01 -2.27154349 0.93082599 468.00 -1.77597665e+01 -1.70051171e+01 2.45882759e+01 -2.37789831 0.90527970 468.25 -2.30369873e+01 -1.74672464e+01 2.89103352e+01 -2.49284756 0.93392201 468.50 -2.87472283e+01 -1.48420706e+01 3.23525918e+01 -2.66499363 0.90169149 468.75 -3.45514119e+01 -1.01122230e+01 3.60007933e+01 -2.85687249 0.93022556 469.00 -3.83390519e+01 -3.70150691e+00 3.85173215e+01 -3.04534432 0.92595633 469.25 -3.92799657e+01 2.33797873e+00 3.93494835e+01 3.08214190 0.94291164 469.50 -3.72327869e+01 1.10258379e+01 3.88310381e+01 2.85368780 0.91420005 469.75 -3.40991298e+01 1.53621608e+01 3.73998214e+01 2.71831075 0.94846832 470.00 -3.04785892e+01 1.78872073e+01 3.53397310e+01 2.61087771 0.91247620 470.25 -2.85812723e+01 2.05137364e+01 3.51809964e+01 2.51906390 0.90560159 470.50 -2.49642479e+01 2.17697173e+01 3.31230172e+01 2.42444397 0.87517396 470.75 -2.28456148e+01 2.44439672e+01 3.34578787e+01 2.32240810 0.88493249 471.00 -1.84456991e+01 2.69712020e+01 3.26755192e+01 2.17063738 0.74619958 471.25 -1.63506713e+01 3.08601689e+01 3.49241246e+01 2.05802289 0.74705744 471.50 -8.67148999e+00 3.05866699e+01 3.17921235e+01 1.84705274 0.68543533 471.75 -2.59089853e+00 2.81318683e+01 2.82509251e+01 1.66263559 0.64759219 472.00 7.58445521e+00 2.19162267e+01 2.31914845e+01 1.23763071 0.60107287 472.25 1.21539236e+01 2.02901431e+01 2.36518026e+01 1.03110781 0.67458831 472.50 1.21751552e+01 1.31178447e+01 1.78972694e+01 0.82265169 0.68573009 472.75 1.11087058e+01 9.61625475e+00 1.46927091e+01 0.71351000 0.72191650 473.00 8.27693770e+00 5.20841046e+00 9.77932703e+00 0.56166242 0.77660955 473.25 6.16609911e+00 4.02406107e+00 7.36300521e+00 0.57820819 0.73372468 473.50 2.85019708e+00 3.12081921e+00 4.22648032e+00 0.83068979 0.65322363 473.75 1.31856855e+00 3.34581852e+00 3.59626537e+00 1.19539128 0.66644260 474.00 -2.99121308e-01 4.12389684e+00 4.13473079e+00 1.64320318 0.81064418 474.25 -8.21036228e-01 4.56780085e+00 4.64100260e+00 1.74864159 0.85896544 474.50 -2.01526614e+00 5.08026429e+00 5.46538040e+00 1.94844194 0.92782462 474.75 -2.22566698e+00 5.43929530e+00 5.87703385e+00 1.95919390 0.94186425 475.00 -2.53183815e+00 6.26511461e+00 6.75735640e+00 1.95484663 0.95381900 475.25 -2.36272299e+00 6.62435624e+00 7.03310426e+00 1.91340269 0.95499587 475.50 -1.74323603e+00 6.63695526e+00 6.86207308e+00 1.82765058 0.95890642 475.75 -1.41975899e+00 6.82664299e+00 6.97271612e+00 1.77584657 0.94739423 476.00 -3.63210332e-01 7.08039479e+00 7.08970466e+00 1.62204943 0.93124786 476.25 1.35989537e-01 6.25366276e+00 6.25514117e+00 1.54905417 0.88454620 476.50 3.92727861e-01 5.06280346e+00 5.07801280e+00 1.49338013 0.84940786 476.75 1.06821147e-01 4.14242042e+00 4.14379750e+00 1.54501491 0.77499535 477.00 -5.24345578e-01 2.80502893e+00 2.85361623e+00 1.75559410 0.60460948 477.25 -9.33806404e-01 2.18624360e+00 2.37732107e+00 1.97446824 0.40643833 477.50 -1.77031162e+00 1.07165729e+00 2.06940875e+00 2.59724897 0.36352248 477.75 -2.35351726e+00 2.83084675e-01 2.37048105e+00 3.02188620 0.33100935 478.00 -3.37272379e+00 -1.36240695e+00 3.63750168e+00 -2.75768698 0.55951790 478.25 -4.32639494e+00 -1.69541518e+00 4.64673281e+00 -2.76810831 0.45607370 478.50 -7.18087812e+00 -4.42525642e+00 8.43492175e+00 -2.58930617 0.45972960 478.75 -8.55321345e+00 2.57797639e+00 8.93327613e+00 2.84884789 0.18589696 479.00 -8.11080856e+00 1.89043094e+01 2.05708077e+01 1.97608854 0.70210180 479.25 -5.41274565e+00 1.75497895e+01 1.83655364e+01 1.86996194 0.82997872 479.50 -4.87658522e+00 1.69225714e+01 1.76112040e+01 1.85136532 0.91596090 479.75 -3.21868696e+00 1.55631110e+01 1.58924626e+01 1.77473623 0.91844200 480.00 -2.55301914e+00 1.52546454e+01 1.54668068e+01 1.73661963 0.95260392 480.25 -2.16083861e+00 1.44533297e+01 1.46139647e+01 1.71920170 0.96004541 480.50 -1.69811322e+00 1.40813582e+01 1.41833789e+01 1.69080979 0.96999556 480.75 -1.10831266e+00 1.45314322e+01 1.45736364e+01 1.64691897 0.96068146 481.00 -7.98465149e-01 1.51141578e+01 1.51352341e+01 1.62357622 0.96114101 481.25 6.89144355e-01 1.48894365e+01 1.49053762e+01 1.52454522 0.92290490 481.50 1.76949884e+00 1.55414811e+01 1.56418913e+01 1.45742801 0.90624000 481.75 5.35266941e+00 1.40633056e+01 1.50475125e+01 1.20711424 0.72867707 482.00 8.43297518e+00 1.07260979e+01 1.36442019e+01 0.90452010 0.63636261 482.25 5.29149118e+00 4.71125719e+00 7.08490107e+00 0.72745564 0.54821071 482.50 4.43311878e+00 3.39797826e+00 5.58558845e+00 0.65397671 0.64376458 482.75 3.56794629e+00 3.53329646e+00 5.02139668e+00 0.78051880 0.75424830 483.00 2.79142447e+00 3.55410377e+00 4.51925925e+00 0.90501598 0.79713441 483.25 1.71699265e+00 3.51781558e+00 3.91447190e+00 1.11672616 0.75851110 483.50 1.15951403e+00 3.88128457e+00 4.05078297e+00 1.28049138 0.78357382 483.75 6.30477866e-01 4.40054001e+00 4.44547576e+00 1.42849191 0.79894024 484.00 7.39795636e-01 4.78157611e+00 4.83846749e+00 1.41729547 0.83032210 484.25 1.19760228e+00 4.51622290e+00 4.67231425e+00 1.31158442 0.85820781 484.50 1.19388208e+00 3.98085566e+00 4.15602770e+00 1.27942587 0.81686666 484.75 7.02582757e-01 3.16593159e+00 3.24295318e+00 1.35241563 0.76055162 485.00 8.28976359e-02 2.88132731e+00 2.88251958e+00 1.54203362 0.66561458 485.25 -1.26356116e+00 3.07387684e+00 3.32344785e+00 1.96080439 0.79629643 485.50 -1.78770408e+00 3.37522371e+00 3.81942679e+00 2.05788552 0.82982855 485.75 -2.65926341e+00 3.85704281e+00 4.68491848e+00 2.17441104 0.92104577 486.00 -2.91319879e+00 4.17465126e+00 5.09062278e+00 2.18006474 0.92502980 486.25 -3.19753380e+00 4.93282423e+00 5.87851829e+00 2.14591614 0.97120392 486.50 -3.40813781e+00 5.44624147e+00 6.42471396e+00 2.12995487 0.96861256 486.75 -3.52694934e+00 6.41990679e+00 7.32492832e+00 2.07316113 0.98096585 487.00 -3.46350469e+00 7.10071531e+00 7.90038117e+00 2.02461088 0.97985435 487.25 -3.09336566e+00 7.92066964e+00 8.50328869e+00 1.94312402 0.99004186 487.50 -2.56490550e+00 8.38795097e+00 8.77134320e+00 1.86755153 0.98611243 487.75 -1.94863941e+00 8.87671522e+00 9.08808389e+00 1.78689120 0.98964289 488.00 -1.39470498e+00 9.13143606e+00 9.23733330e+00 1.72236163 0.98733202 488.25 -7.75715608e-01 9.35687095e+00 9.38897059e+00 1.65351049 0.99080971 488.50 -2.78270880e-01 9.55733520e+00 9.56138540e+00 1.59990405 0.99048108 488.75 2.67384714e-01 9.56699814e+00 9.57073393e+00 1.54285495 0.99416199 489.00 8.97138980e-01 9.33864422e+00 9.38163814e+00 1.47502287 0.99111140 489.25 1.50797266e+00 9.11105887e+00 9.23500814e+00 1.40677313 0.99399267 489.50 1.67613314e+00 8.72261150e+00 8.88219420e+00 1.38095090 0.99306708 489.75 1.79123002e+00 8.24095315e+00 8.43337499e+00 1.35676827 0.99393493 490.00 1.70273388e+00 8.24739226e+00 8.42132898e+00 1.36719966 0.99159131 490.25 1.75957143e+00 8.54267516e+00 8.72200610e+00 1.36766291 0.99294508 490.50 2.21299751e+00 8.52911502e+00 8.81153568e+00 1.31693048 0.99025835 490.75 2.65727813e+00 8.29238658e+00 8.70774380e+00 1.26068711 0.99115165 491.00 2.64910699e+00 7.85118051e+00 8.28606078e+00 1.24537668 0.99038887 491.25 2.65263551e+00 7.59297116e+00 8.04298988e+00 1.23469705 0.99398845 491.50 2.58902074e+00 7.71016517e+00 8.13324507e+00 1.24683356 0.99283223 491.75 2.76595090e+00 7.84566318e+00 8.31894915e+00 1.23185587 0.99394695 492.00 2.91068955e+00 7.58350988e+00 8.12291424e+00 1.20431708 0.99171804 492.25 2.80734881e+00 7.46660580e+00 7.97692983e+00 1.21116038 0.99156154 492.50 2.58545999e+00 7.52306135e+00 7.95493906e+00 1.23977067 0.98928230 492.75 2.43757615e+00 7.65932484e+00 8.03785011e+00 1.26268211 0.98815991 493.00 2.42504669e+00 8.29401493e+00 8.64126930e+00 1.28634020 0.97533678 493.25 2.41589790e+00 9.00264599e+00 9.32116932e+00 1.30861910 0.97035706 493.50 2.81901384e+00 9.89087092e+00 1.02847541e+01 1.29314636 0.96340665 493.75 3.39752599e+00 1.05690206e+01 1.11016836e+01 1.25976882 0.96471646 494.00 4.68991949e+00 1.21525903e+01 1.30261582e+01 1.20248708 0.96065960 494.25 5.58236175e+00 1.27875433e+01 1.39529218e+01 1.15918619 0.95546940 494.50 7.85810151e+00 1.35332430e+01 1.56492308e+01 1.04472496 0.93956574 494.75 9.17848601e+00 1.35409257e+01 1.63585230e+01 0.97510299 0.92817804 495.00 1.20112360e+01 1.28226268e+01 1.75695631e+01 0.81805930 0.94204551 495.25 1.34756244e+01 1.25210275e+01 1.83947977e+01 0.74869466 0.94277580 495.50 1.74346251e+01 1.14485764e+01 2.08575179e+01 0.58104110 0.94430341 495.75 1.93708717e+01 9.91619379e+00 2.17614699e+01 0.47313223 0.92435778 496.00 2.22274980e+01 5.06424061e+00 2.27971095e+01 0.22401284 0.89700915 496.25 2.23072601e+01 1.39615693e+00 2.23509084e+01 0.06250603 0.89874670 496.50 1.92404875e+01 -3.07197616e+00 1.94841832e+01 -0.15832575 0.89971485 496.75 1.65348522e+01 -4.52779527e+00 1.71435780e+01 -0.26728134 0.89460055 497.00 1.50210992e+01 -5.40039983e+00 1.59623851e+01 -0.34513143 0.95396938 497.25 1.48475932e+01 -5.53242577e+00 1.58448338e+01 -0.35667747 0.96494867 497.50 1.47952845e+01 -6.40978458e+00 1.61240746e+01 -0.40882217 0.97562157 497.75 1.43477419e+01 -6.95518400e+00 1.59446631e+01 -0.45137990 0.96527445 498.00 1.36042821e+01 -7.83746662e+00 1.57003941e+01 -0.52266276 0.96923750 498.25 1.28903777e+01 -8.61706769e+00 1.55053440e+01 -0.58926273 0.93848480 498.50 1.15687232e+01 -1.05790958e+01 1.56764991e+01 -0.74074503 0.93154692 498.75 9.91648900e+00 -1.16666247e+01 1.53116585e+01 -0.86630933 0.92237786 499.00 7.93092379e+00 -1.18032351e+01 1.42202641e+01 -0.97916012 0.94295109 499.25 6.63619945e+00 -1.21145840e+01 1.38131201e+01 -1.06965452 0.93233536 499.50 4.90970427e+00 -1.18393990e+01 1.28170419e+01 -1.17768893 0.92481230 499.75 3.59671203e+00 -1.14531051e+01 1.20045806e+01 -1.26651076 0.90357248 500.00 2.29605421e+00 -1.13238478e+01 1.15542803e+01 -1.37074572 0.90080223 500.25 1.76498443e+00 -1.01615329e+01 1.03136764e+01 -1.39881936 0.86273045 500.50 1.23835422e+00 -8.75721025e+00 8.84433449e+00 -1.43031808 0.86919489 500.75 2.42452816e+00 -7.59333548e+00 7.97101502e+00 -1.26173134 0.82786945 501.00 3.66267600e+00 -6.98416639e+00 7.88630304e+00 -1.08779968 0.84216971 501.25 5.31446252e+00 -7.51534556e+00 9.20456033e+00 -0.95528906 0.81163412 501.50 6.38626143e+00 -8.27645871e+00 1.04539038e+01 -0.91360288 0.78138147 501.75 7.91883646e+00 -6.58055574e+00 1.02961976e+01 -0.69335984 0.57672526 502.00 1.00844784e+01 -5.05909099e+00 1.12823360e+01 -0.46498357 0.49770630 502.25 7.18850749e+00 2.13973270e-01 7.19169135e+00 0.02975724 0.22657301 502.50 4.36651176e+00 1.83101273e+00 4.73487408e+00 0.39705897 0.12330308 502.75 2.84448541e+00 2.63888180e+00 3.88005083e+00 0.74791985 0.09208023 503.00 2.88265811e+00 3.52544126e+00 4.55394926e+00 0.88537168 0.16086542 503.25 2.64433090e+00 2.39098472e+00 3.56500965e+00 0.73512669 0.18306614 503.50 2.75116982e+00 2.28930496e+00 3.57908544e+00 0.69402211 0.24067397 503.75 2.64559084e+00 1.21359241e+00 2.91066272e+00 0.43008395 0.29346489 504.00 2.13334781e+00 7.64750463e-01 2.26627804e+00 0.34420431 0.26038332 504.25 2.17488596e+00 2.63597422e-01 2.19080181e+00 0.12061229 0.25087609 504.50 2.30315535e+00 6.47884366e-02 2.30406643e+00 0.02812288 0.32724462 504.75 4.16354077e+00 -6.68604337e-02 4.16407758e+00 -0.01605717 0.54379518 505.00 5.47360541e+00 -3.92493064e-01 5.48765952e+00 -0.07158397 0.65471192 505.25 4.82483811e+00 -2.42090203e+00 5.39813204e+00 -0.46505317 0.66543474 505.50 5.28661854e+00 -3.60210643e+00 6.39714830e+00 -0.59810812 0.77820600 505.75 5.89662587e+00 -5.01809410e+00 7.74283314e+00 -0.70508077 0.89602479 506.00 5.77695352e+00 -5.54838328e+00 8.00985324e+00 -0.76521870 0.90491564 506.25 5.01746332e+00 -7.31158782e+00 8.86759576e+00 -0.96936887 0.92088113 506.50 4.43845317e+00 -7.71521180e+00 8.90080669e+00 -1.04874715 0.94728561 506.75 3.50888335e+00 -7.88690275e+00 8.63223594e+00 -1.15219162 0.92403706 507.00 3.39764854e+00 -7.72324343e+00 8.43756510e+00 -1.15635222 0.91563451 507.25 4.25451713e+00 -8.31088555e+00 9.33658046e+00 -1.09765743 0.94033135 507.50 4.32682580e+00 -9.12152486e+00 1.00957237e+01 -1.12787574 0.93709059 507.75 4.38630550e+00 -1.09652596e+01 1.18100209e+01 -1.19027410 0.92662803 508.00 3.45862378e+00 -1.23156531e+01 1.27920831e+01 -1.29701671 0.90689311 508.25 1.26122583e+00 -1.51162042e+01 1.51687283e+01 -1.48755378 0.92822635 508.50 -8.54080958e-01 -1.54241647e+01 1.54477931e+01 -1.62611275 0.92203749 508.75 -3.26848350e+00 -1.49688127e+01 1.53214992e+01 -1.78577502 0.95671527 509.00 -4.60669539e+00 -1.41369607e+01 1.48686012e+01 -1.88580749 0.95057853 509.25 -5.88838153e+00 -1.35568996e+01 1.47804791e+01 -1.98055619 0.96743011 509.50 -6.40796057e+00 -1.23353609e+01 1.39004708e+01 -2.04990540 0.95419940 509.75 -7.36083587e+00 -1.12346154e+01 1.34312504e+01 -2.15081316 0.96550783 510.00 -7.50967665e+00 -1.07802805e+01 1.31381008e+01 -2.17924509 0.96500255 510.25 -7.92207555e+00 -1.05243278e+01 1.31727278e+01 -2.21604831 0.97706502 510.50 -8.29634860e+00 -1.01166433e+01 1.30834197e+01 -2.25765541 0.97238478 510.75 -8.96047493e+00 -9.71791116e+00 1.32184685e+01 -2.31566521 0.97754963 511.00 -9.42894431e+00 -9.00263221e+00 1.30365784e+01 -2.37931981 0.98036878 511.25 -9.53938748e+00 -8.47269982e+00 1.27587835e+01 -2.41534606 0.98348976 511.50 -9.58996252e+00 -7.66498047e+00 1.22767792e+01 -2.46729628 0.97520185 511.75 -9.69848411e+00 -7.08481719e+00 1.20106298e+01 -2.51068378 0.97796366 512.00 -9.27352864e+00 -6.72978996e+00 1.14581153e+01 -2.51382648 0.97937669 512.25 -8.92797828e+00 -6.93719225e+00 1.13063448e+01 -2.48102359 0.98690971 512.50 -9.05638485e+00 -7.40139028e+00 1.16960970e+01 -2.45641761 0.98621056 512.75 -9.30379925e+00 -7.75149257e+00 1.21097613e+01 -2.44696054 0.98596531 513.00 -9.99295198e+00 -7.23578908e+00 1.23375740e+01 -2.51488169 0.98515312 513.25 -1.02008968e+01 -7.07701615e+00 1.24154119e+01 -2.53506412 0.98811191 513.50 -1.09946258e+01 -7.41328859e+00 1.32604164e+01 -2.54834827 0.97934036 513.75 -1.12579484e+01 -7.51762601e+00 1.35372118e+01 -2.55283238 0.97568222 514.00 -1.16792605e+01 -6.66536751e+00 1.34473882e+01 -2.62299507 0.96125391 514.25 -1.21046743e+01 -6.48561300e+00 1.37326733e+01 -2.64972147 0.96825001 514.50 -1.31032706e+01 -6.38197042e+00 1.45748155e+01 -2.68835723 0.97395363 514.75 -1.37807790e+01 -6.01891857e+00 1.50378606e+01 -2.72980194 0.97897633 515.00 -1.49034898e+01 -5.34975579e+00 1.58345791e+01 -2.79695811 0.96196740 515.25 -1.54057430e+01 -4.91234620e+00 1.61699741e+01 -2.83291998 0.94869056 515.50 -1.60626086e+01 -3.19399586e+00 1.63770878e+01 -2.94530633 0.92888206 515.75 -1.65020044e+01 -2.84645681e+00 1.67457000e+01 -2.97078190 0.90455673 516.00 -1.77344419e+01 -1.87885758e+00 1.78336910e+01 -3.03604239 0.81838083 516.25 -1.92541207e+01 -1.61311193e+00 1.93215758e+01 -3.05800776 0.79336931 516.50 -1.50796603e+01 -3.51155024e+00 1.54831243e+01 -2.91280334 0.49590585 516.75 -9.02615532e+00 -6.12625897e+00 1.09088280e+01 -2.54528976 0.24541474 517.00 -4.36681385e+00 -2.98372805e+00 5.28882750e+00 -2.54218098 0.14282301 517.25 -4.02339765e+00 -1.43454149e+00 4.27149130e+00 -2.79909481 0.13914850 517.50 -6.37264982e+00 9.00232368e-01 6.43592138e+00 3.00125625 0.36647736 517.75 -6.81017867e+00 2.53409826e+00 7.26637375e+00 2.78536290 0.45998740 518.00 -4.23643881e+00 6.62393525e+00 7.86281960e+00 2.13980104 0.49129547 518.25 1.07120306e+00 7.00300267e+00 7.08445639e+00 1.41900946 0.38749009 518.50 9.51884140e+00 5.64540439e+00 1.10670200e+01 0.53531339 0.59576376 518.75 9.78318611e+00 3.42431423e-01 9.78917717e+00 0.03498775 0.49943866 519.00 7.26274449e+00 -7.71571090e+00 1.05962093e+01 -0.81563015 0.67978676 519.25 5.61372781e+00 -8.55731703e+00 1.02343351e+01 -0.99020429 0.68633840 519.50 3.27520131e+00 -1.00380867e+01 1.05588885e+01 -1.25540945 0.80732808 519.75 2.43985199e+00 -9.70320506e+00 1.00052519e+01 -1.32445526 0.83445658 520.00 2.16508731e+00 -9.96444400e+00 1.01969479e+01 -1.35684069 0.90181731 520.25 2.13344762e+00 -1.01737260e+01 1.03950132e+01 -1.36408985 0.86239036 520.50 1.32555054e+00 -1.02476949e+01 1.03330700e+01 -1.44215950 0.88268537 520.75 1.18135915e+00 -9.08308147e+00 9.15958396e+00 -1.44146085 0.85384748 521.00 1.39425925e+00 -8.26752457e+00 8.38426630e+00 -1.40372545 0.87871060 521.25 1.81381134e+00 -6.51474704e+00 6.76253211e+00 -1.29925685 0.80961840 521.50 1.68282715e+00 -5.43679803e+00 5.69128105e+00 -1.27062369 0.83511765 521.75 2.54535535e+00 -4.23933532e+00 4.94477480e+00 -1.03007263 0.77376377 522.00 3.14526161e+00 -3.37508770e+00 4.61344639e+00 -0.82063109 0.81472147 522.25 3.37440279e+00 -2.34108051e+00 4.10697603e+00 -0.60653673 0.72766464 522.50 3.82382983e+00 -1.88056533e+00 4.26124402e+00 -0.45706734 0.82125274 522.75 4.24289052e+00 -9.79940319e-01 4.35458413e+00 -0.22698048 0.79232761 523.00 4.49390860e+00 -6.55705030e-01 4.54149354e+00 -0.14488731 0.85460274 523.25 4.47687300e+00 -2.94238000e-01 4.48653183e+00 -0.06562961 0.83503465 523.50 4.42191201e+00 -8.40922604e-02 4.42271154e+00 -0.01901488 0.78939644 523.75 3.95518778e+00 9.07462009e-01 4.05795486e+00 0.22553255 0.87102899 524.00 4.12541343e+00 1.27320166e+00 4.31741571e+00 0.29934984 0.90531339 524.25 4.37034000e+00 1.94611647e+00 4.78406115e+00 0.41893931 0.93709159 524.50 4.53417223e+00 2.22807886e+00 5.05203456e+00 0.45674159 0.94498905 524.75 5.01552852e+00 2.51043937e+00 5.60872821e+00 0.46407421 0.92674426 525.00 5.58980048e+00 2.71328902e+00 6.21351806e+00 0.45189952 0.92679801 525.25 6.24199651e+00 1.68527976e+00 6.46549985e+00 0.26370298 0.93329997 525.50 6.00154093e+00 9.78179343e-01 6.08073419e+00 0.16156734 0.92461500 525.75 5.37723841e+00 -1.02769528e-01 5.37822039e+00 -0.01910963 0.92161349 526.00 5.07153215e+00 -3.88825456e-01 5.08641559e+00 -0.07651855 0.91655721 526.25 4.52201575e+00 -1.23971836e+00 4.68887279e+00 -0.26757739 0.89718666 526.50 4.08104359e+00 -1.78059959e+00 4.45257810e+00 -0.41141107 0.91581477 526.75 3.49903103e+00 -1.76051747e+00 3.91696821e+00 -0.46615987 0.91439383 527.00 3.05879058e+00 -1.83130070e+00 3.56508935e+00 -0.53946374 0.87755854 527.25 2.32501417e+00 -2.29108784e+00 3.26416519e+00 -0.77804873 0.84914926 527.50 1.94118604e+00 -2.34680542e+00 3.04560321e+00 -0.87971178 0.76772805 527.75 8.03869710e-01 -2.82961856e+00 2.94158932e+00 -1.29399791 0.72507972 528.00 1.13764654e-01 -2.98680519e+00 2.98897100e+00 -1.53272565 0.72010912 528.25 -1.21170437e+00 -3.13149483e+00 3.35775034e+00 -1.93999468 0.79959346 528.50 -2.00562187e+00 -3.08544628e+00 3.68001329e+00 -2.14719018 0.82696734 528.75 -2.75846456e+00 -2.49240327e+00 3.71768756e+00 -2.40682116 0.87941371 529.00 -3.24038968e+00 -1.88943306e+00 3.75101088e+00 -2.61370111 0.85098898 529.25 -3.32928536e+00 -1.14067287e+00 3.51927203e+00 -2.81150936 0.89092078 529.50 -3.27406190e+00 -1.03324336e+00 3.43323072e+00 -2.83590013 0.89368364 529.75 -3.23277088e+00 -1.02486116e+00 3.39133424e+00 -2.83459295 0.92071595 530.00 -3.50803091e+00 -1.07742336e+00 3.66975776e+00 -2.84360700 0.89372906 530.25 -4.38663787e+00 -1.10012253e+00 4.52248398e+00 -2.89587111 0.92102823 530.50 -4.87005744e+00 -1.03197909e+00 4.97819649e+00 -2.93277867 0.91084316 530.75 -5.47697577e+00 -5.49252231e-01 5.50444743e+00 -3.04164297 0.92535608 531.00 -5.70221938e+00 1.07418571e-02 5.70222949e+00 3.13970885 0.91358575 531.25 -6.25788483e+00 8.67686040e-01 6.31775289e+00 3.00381625 0.93571508 531.50 -6.48504213e+00 9.91587845e-01 6.56041293e+00 2.98986398 0.94037463 531.75 -6.92748411e+00 1.27341246e+00 7.04355133e+00 2.95980175 0.93122772 532.00 -7.17686443e+00 2.20407394e+00 7.50768439e+00 2.84362740 0.91333716 532.25 -7.03807087e+00 3.03247774e+00 7.66357376e+00 2.73476249 0.91523612 532.50 -6.50946709e+00 3.77012182e+00 7.52243181e+00 2.61662627 0.86889785 532.75 -6.05921086e+00 4.51189391e+00 7.55454982e+00 2.50153469 0.88462057 533.00 -5.51463792e+00 5.00474328e+00 7.44705893e+00 2.40462850 0.86893197 533.25 -5.55372830e+00 5.30405278e+00 7.67964022e+00 2.37918552 0.89083460 533.50 -4.60951131e+00 4.72811240e+00 6.60322961e+00 2.34349375 0.84974370 533.75 -4.08476735e+00 4.64731206e+00 6.18731231e+00 2.29186063 0.86012187 534.00 -3.06026023e+00 4.11463788e+00 5.12790772e+00 2.21028516 0.77530102 534.25 -2.42251058e+00 3.73942274e+00 4.45554036e+00 2.14564462 0.80073394 534.50 -2.64309147e+00 3.14631454e+00 4.10916387e+00 2.26949105 0.68610312 534.75 -2.85687122e+00 2.94118422e+00 4.10027777e+00 2.34165391 0.69388609 535.00 -2.67264057e+00 1.69392145e+00 3.16423411e+00 2.57668977 0.52147238 535.25 -2.58272073e+00 1.05120926e+00 2.78845607e+00 2.75505247 0.44822573 535.50 -3.42318440e+00 7.07550607e-01 3.49554277e+00 2.93776922 0.56374737 535.75 -3.53467014e+00 2.98669055e-02 3.53479632e+00 3.13314315 0.56527748 536.00 -4.09730240e+00 -5.42846550e-01 4.13310650e+00 -3.00987103 0.47116503 536.25 -4.86898050e+00 -1.58321964e+00 5.11991753e+00 -2.82721197 0.57729462 536.50 -5.66056043e+00 -2.76754002e+00 6.30089059e+00 -2.68685129 0.63777015 536.75 -6.85916198e+00 -3.91645917e+00 7.89852869e+00 -2.62278312 0.66679338 537.00 -8.29555074e+00 -4.71902868e+00 9.54386682e+00 -2.62438301 0.57448317 537.25 -1.02396092e+01 -6.60476526e+00 1.21849300e+01 -2.56872542 0.43218128 537.50 -1.57579161e+01 1.37614216e+00 1.58178914e+01 3.05448344 0.39832139 537.75 -1.60920476e+01 7.41653689e+00 1.77188886e+01 2.70972610 0.50662050 538.00 -1.07038409e+01 1.16311865e+01 1.58068564e+01 2.31469853 0.54129780 538.25 -8.22647536e+00 1.07346858e+01 1.35243623e+01 2.22467658 0.48621413 538.50 -8.81244164e+00 9.52007433e+00 1.29726999e+01 2.31761378 0.43103135 538.75 -6.95866442e+00 7.96768709e+00 1.05786128e+01 2.28869709 0.30834711 539.00 -4.55643040e-01 8.64993690e+00 8.66192929e+00 1.62342357 0.13007714 539.25 5.10785224e+00 8.55983497e+00 9.96799524e+00 1.03278971 0.20216208 539.50 6.21332117e+00 8.39420401e+00 1.04435636e+01 0.93360206 0.44735753 539.75 4.63979110e+00 8.49769330e+00 9.68186205e+00 1.07102474 0.60063843 540.00 3.42703275e+00 7.73572004e+00 8.46084617e+00 1.15376707 0.76957813 540.25 2.04906271e+00 7.18518383e+00 7.47164805e+00 1.29299173 0.75915737 540.50 1.11172894e+00 7.45783815e+00 7.54024477e+00 1.42281748 0.81425796 540.75 -3.30740277e-01 7.62767181e+00 7.63483898e+00 1.61412976 0.80478497 541.00 -1.78789758e+00 7.84896517e+00 8.05002062e+00 1.79476254 0.86592393 541.25 -2.18858253e+00 7.84770384e+00 8.14716816e+00 1.84276791 0.86748404 541.50 -2.77382367e+00 8.05528274e+00 8.51948812e+00 1.90242746 0.89337878 541.75 -4.01287863e+00 7.76010503e+00 8.73627065e+00 2.04804321 0.85190290 542.00 -5.28672068e+00 8.57742014e+00 1.00757904e+01 2.12315357 0.88969718 542.25 -5.75244366e+00 1.02752826e+01 1.17759093e+01 2.08115761 0.88037028 542.50 -5.61302937e+00 1.31133939e+01 1.42641928e+01 1.97523727 0.86171283 542.75 -3.13144618e+00 1.70405106e+01 1.73258465e+01 1.75253351 0.89172391 543.00 -2.67017147e-01 1.77684851e+01 1.77704913e+01 1.58582277 0.90917278 543.25 4.38647497e+00 1.45083810e+01 1.51569879e+01 1.27719343 0.82884508 543.50 6.12197243e+00 1.15018441e+01 1.30296187e+01 1.08167495 0.86500628 543.75 4.48085735e+00 8.64479812e+00 9.73707436e+00 1.09259256 0.86914750 544.00 3.89948511e+00 7.41462034e+00 8.37750434e+00 1.08662965 0.91472432 544.25 3.48632273e+00 6.85465807e+00 7.69030451e+00 1.10028735 0.89688323 544.50 3.10783948e+00 6.54607381e+00 7.24636106e+00 1.12754065 0.86816724 544.75 2.56054998e+00 5.13465271e+00 5.73768897e+00 1.10820506 0.82970963 545.00 1.91487737e+00 4.92923944e+00 5.28811467e+00 1.20026618 0.86558818 545.25 5.50908276e-01 4.61819846e+00 4.65094151e+00 1.45206666 0.84509613 545.50 -7.72287742e-02 4.78209300e+00 4.78271657e+00 1.58694450 0.86027875 545.75 -3.41590467e-01 5.09996184e+00 5.11138874e+00 1.63767546 0.89390399 546.00 -4.15582063e-01 5.30723292e+00 5.32347910e+00 1.64894171 0.91377104 546.25 -2.04474340e-01 5.11872922e+00 5.12281159e+00 1.61072141 0.87735697 546.50 -1.09646562e-01 4.81253998e+00 4.81378888e+00 1.59357590 0.87091682 546.75 1.69121696e-01 4.26801268e+00 4.27136212e+00 1.53119165 0.72326843 547.00 4.33896532e-01 4.26241875e+00 4.28444626e+00 1.46934992 0.79858477 547.25 5.37604566e-01 3.99342709e+00 4.02945140e+00 1.43697850 0.84814950 547.50 6.19423678e-01 3.31603947e+00 3.37339642e+00 1.38612833 0.75010359 547.75 4.28211421e-01 1.93886120e+00 1.98558500e+00 1.35342856 0.62913269 548.00 1.46136699e-01 1.49936497e+00 1.50646980e+00 1.47363748 0.55515832 548.25 -4.60934800e-01 8.17761167e-01 9.38719456e-01 2.08406240 0.38476315 548.50 -7.41344089e-01 4.08857790e-01 8.46614287e-01 2.63759179 0.33119832 548.75 -1.37194026e+00 8.75867614e-03 1.37196822e+00 3.13520859 0.59573894 549.00 -1.74732693e+00 -2.79783308e-01 1.76958473e+00 -2.98281965 0.68186804 549.25 -2.20402576e+00 -4.58973567e-01 2.25130768e+00 -2.93628357 0.83176368 549.50 -2.36958060e+00 -4.18646745e-01 2.40627873e+00 -2.96672178 0.86289142 549.75 -2.43212873e+00 -4.29922410e-01 2.46983470e+00 -2.96663209 0.87705387 550.00 -2.48267442e+00 -4.60937206e-01 2.52510106e+00 -2.95802130 0.81484650 550.25 -2.39875325e+00 -8.05034377e-01 2.53023665e+00 -2.81779870 0.80961731 550.50 -2.28817370e+00 -1.00849301e+00 2.50055935e+00 -2.72646476 0.79465582 550.75 -2.17150776e+00 -1.56609906e+00 2.67733304e+00 -2.51677742 0.77679919 551.00 -2.22912164e+00 -1.91587516e+00 2.93931300e+00 -2.43162330 0.78219847 551.25 -2.40597145e+00 -1.91514966e+00 3.07514176e+00 -2.46929642 0.81859825 551.50 -2.47843749e+00 -2.10305039e+00 3.25045741e+00 -2.43794750 0.74905735 551.75 -2.45119187e+00 -2.57736643e+00 3.55684682e+00 -2.33110816 0.71888027 552.00 -2.46111189e+00 -2.69650412e+00 3.65078159e+00 -2.31058640 0.70881520 552.25 -2.78619520e+00 -2.71312208e+00 3.88894781e+00 -2.36948138 0.77398683 552.50 -2.73651873e+00 -2.42825511e+00 3.65854583e+00 -2.41580956 0.61106230 552.75 -2.75430324e+00 -2.60611719e+00 3.79183771e+00 -2.38383193 0.61585911 553.00 -2.25229333e+00 -2.68365794e+00 3.50354751e+00 -2.26902357 0.53207975 553.25 -1.88832989e+00 -2.77788331e+00 3.35893219e+00 -2.16781770 0.49730133 553.50 -2.05349428e+00 -2.30129013e+00 3.08427869e+00 -2.29935380 0.37709363 553.75 -2.19721447e+00 -2.18264010e+00 3.09704201e+00 -2.35952207 0.42657202 554.00 -1.10527440e+00 -1.07684905e+00 1.54312520e+00 -2.36922022 0.16707793 554.25 -8.48429689e-01 -6.68411131e-01 1.08009554e+00 -2.47432188 0.10321912 554.50 -4.51790187e-01 -4.14432817e-02 4.53687027e-01 -3.05011740 0.01286967 554.75 1.12194423e-01 -4.27457158e-01 4.41935754e-01 -1.31411663 0.00967231 555.00 6.54306383e-01 -4.76024892e-01 8.09145562e-01 -0.62896191 0.02792235 555.25 1.21745102e+00 6.51848587e-02 1.21919484e+00 0.05349100 0.05921619 555.50 2.30393470e+00 4.16397853e-01 2.34126083e+00 0.17880319 0.12197157 555.75 1.76283162e+00 5.59960732e-01 1.84963006e+00 0.30756837 0.06041391 556.00 1.40550505e+00 2.68256890e+00 3.02846831e+00 1.08818068 0.11876711 556.25 7.31194486e-01 3.47330603e+00 3.54943659e+00 1.36330777 0.16585087 556.50 -1.05455034e+00 3.41841134e+00 3.57737509e+00 1.87002503 0.22593296 556.75 -1.40277361e+00 3.00213768e+00 3.31369951e+00 2.00790917 0.24482115 557.00 -1.60164267e+00 1.65851093e+00 2.30562741e+00 2.33875283 0.23967722 557.25 -1.59382508e+00 7.81181807e-01 1.77497138e+00 2.68587201 0.24081843 557.50 -1.98496379e+00 -4.81017122e-01 2.04241493e+00 -2.90384534 0.37560601 557.75 -1.70710349e+00 -7.15576961e-01 1.85101397e+00 -2.74466524 0.37556838 558.00 -1.15883565e+00 -7.15802721e-01 1.36208429e+00 -2.58826629 0.34961564 558.25 -9.05529135e-01 -6.91457381e-01 1.13934030e+00 -2.48944747 0.26200344 558.50 -2.28650027e-01 -1.39579996e+00 1.41440389e+00 -1.73316708 0.41466163 558.75 2.52089051e-01 -1.58487035e+00 1.60479373e+00 -1.41305800 0.48745151 559.00 8.13231090e-01 -1.59579102e+00 1.79105940e+00 -1.09949029 0.51038968 559.25 7.74820499e-01 -1.54754763e+00 1.73067919e+00 -1.10660778 0.42054891 559.50 7.11091298e-01 -1.97595152e+00 2.10000839e+00 -1.22535332 0.58035944 559.75 7.96252150e-01 -2.04098772e+00 2.19080998e+00 -1.19882674 0.58860665 560.00 9.96816943e-01 -1.99581891e+00 2.23090500e+00 -1.10758673 0.58182652 560.25 1.22300371e+00 -2.14993447e+00 2.47345028e+00 -1.05359148 0.60641413 560.50 1.19549777e+00 -2.86617476e+00 3.10550683e+00 -1.17563120 0.69048379 560.75 1.17515668e+00 -3.00925236e+00 3.23057162e+00 -1.19849375 0.66888859 561.00 8.38308400e-01 -3.29806857e+00 3.40294244e+00 -1.32188591 0.78334872 561.25 2.79434128e-01 -3.10148750e+00 3.11405012e+00 -1.48094212 0.66997759 561.50 -5.13809943e-01 -2.81685461e+00 2.86333207e+00 -1.75121835 0.68868519 561.75 -8.85440794e-01 -2.11074046e+00 2.28893658e+00 -1.96799324 0.60391035 562.00 -1.37461819e+00 -1.74161183e+00 2.21873543e+00 -2.23896599 0.71405402 562.25 -1.34111853e+00 -8.97079914e-01 1.61349041e+00 -2.55204254 0.51483542 562.50 -1.06615949e+00 -1.01231813e-01 1.07095468e+00 -3.04692649 0.45383518 562.75 -9.25176294e-01 4.03230826e-01 1.00923054e+00 2.73057457 0.39783404 563.00 -7.57974380e-01 6.98184383e-01 1.03052734e+00 2.39723152 0.48661545 563.25 -5.25845804e-01 9.02837954e-01 1.04481107e+00 2.09820140 0.49598528 563.50 -5.05001323e-01 1.07786481e+00 1.19030201e+00 2.00894438 0.62337758 563.75 -5.72850262e-01 1.57760138e+00 1.67838718e+00 1.91910652 0.73882416 564.00 -5.70038840e-01 1.88009955e+00 1.96461666e+00 1.86518273 0.86204692 564.25 -3.82530432e-01 2.30626551e+00 2.33777461e+00 1.73516562 0.86567921 564.50 -2.32357103e-01 2.63692390e+00 2.64714138e+00 1.65868605 0.89867675 564.75 2.15435067e-01 2.92058949e+00 2.92852442e+00 1.49716544 0.90976539 565.00 5.35082692e-01 3.13475960e+00 3.18009925e+00 1.40173235 0.92373856 565.25 1.05763395e+00 3.45008833e+00 3.60855914e+00 1.27333876 0.93896609 565.50 1.38682755e+00 3.47217444e+00 3.73888834e+00 1.19079709 0.95158067 565.75 1.85457328e+00 3.19942645e+00 3.69807675e+00 1.04546845 0.94070385 566.00 2.13849383e+00 2.81552353e+00 3.53558038e+00 0.92121953 0.93584018 566.25 2.44190449e+00 2.11944332e+00 3.23340958e+00 0.71482131 0.92857172 566.50 2.30900688e+00 1.67317399e+00 2.85149504e+00 0.62706515 0.93035323 566.75 1.97504516e+00 1.39934315e+00 2.42052983e+00 0.61641589 0.92954502 567.00 1.73462945e+00 1.30057838e+00 2.16805061e+00 0.64335583 0.91105593 567.25 1.32977384e+00 1.22561305e+00 1.80843186e+00 0.74465946 0.85936559 567.50 1.05369575e+00 1.10315477e+00 1.52552456e+00 0.80832528 0.81116056 567.75 5.12838150e-01 1.40405550e+00 1.49478253e+00 1.22059656 0.77319197 568.00 3.03329840e-01 1.59627070e+00 1.62483511e+00 1.38301116 0.76999768 568.25 5.22308574e-02 1.90682892e+00 1.90754412e+00 1.54341170 0.76408757 568.50 1.64240205e-01 2.30068939e+00 2.30654428e+00 1.49952984 0.78880329 568.75 7.23514138e-01 2.60287693e+00 2.70156270e+00 1.29967373 0.84765660 569.00 1.05650632e+00 2.57930120e+00 2.78729264e+00 1.18203343 0.88559701 569.25 1.28642916e+00 2.32411633e+00 2.65639167e+00 1.06525981 0.88173508 569.50 1.25616445e+00 2.26426235e+00 2.58936925e+00 1.06429168 0.86446141 569.75 1.17467773e+00 2.26069586e+00 2.54766825e+00 1.09158493 0.90803586 570.00 1.13404681e+00 2.23523234e+00 2.50645682e+00 1.10128542 0.87449578 570.25 8.09497121e-01 2.34583833e+00 2.48158076e+00 1.23851310 0.83870560 570.50 7.11440300e-01 2.51554795e+00 2.61421667e+00 1.29517712 0.77296279 570.75 9.40898062e-01 2.95978275e+00 3.10573713e+00 1.26300465 0.75390784 571.00 1.46989729e+00 3.01712999e+00 3.35613936e+00 1.11745403 0.70974878 571.25 2.36158366e+00 3.46058304e+00 4.18959573e+00 0.97196424 0.75353942 571.50 2.85934106e+00 2.94531329e+00 4.10496062e+00 0.80020799 0.67093132 571.75 3.80742144e+00 1.89168570e+00 4.25146243e+00 0.46111777 0.71224536 572.00 3.94693532e+00 8.14878486e-01 4.03017684e+00 0.20359791 0.75611074 572.25 3.65405930e+00 -1.92693071e-01 3.65913651e+00 -0.05268517 0.78427042 572.50 2.67346199e+00 -6.12170530e-01 2.74265415e+00 -0.22509985 0.61382422 572.75 1.94711966e+00 -9.45620006e-01 2.16459515e+00 -0.45210240 0.59732940 573.00 9.11209105e-01 -6.93093840e-01 1.14484982e+00 -0.65027027 0.30595125 573.25 2.40563007e-01 -1.34998658e-01 2.75853580e-01 -0.51138461 0.04140937 573.50 5.29050982e-01 4.78471170e-01 7.13322929e-01 0.73523809 0.29776340 573.75 7.86684013e-01 7.75944969e-01 1.10497164e+00 0.77852585 0.66411364 574.00 8.71466058e-01 7.27374606e-01 1.13513299e+00 0.69551852 0.62039648 574.25 8.00150488e-01 6.46116567e-01 1.02844904e+00 0.67929366 0.63197356 574.50 5.36166166e-01 7.96079806e-01 9.59800612e-01 0.97807232 0.44654483 574.75 2.99344741e-01 9.63650330e-01 1.00907345e+00 1.26961028 0.48484300 575.00 5.93490278e-01 1.09966827e+00 1.24960034e+00 1.07589584 0.60178595 575.25 7.79020061e-01 9.70891083e-01 1.24478984e+00 0.89460806 0.57340291 575.50 6.38432049e-01 2.47769505e-01 6.84824948e-01 0.37019772 0.17226382 575.75 5.13096816e-01 -2.71508956e-01 5.80504484e-01 -0.48670050 0.08399034 576.00 1.22419431e+00 -9.72041738e-01 1.56317524e+00 -0.67108744 0.14169316 576.25 1.70684577e+00 -4.37646046e-01 1.76206031e+00 -0.25099900 0.08972904 576.50 4.09641372e+00 1.15778975e+00 4.25688647e+00 0.27545043 0.48553291 576.75 4.62230646e+00 1.48866377e+00 4.85611334e+00 0.31157121 0.70162599 577.00 4.24244058e+00 1.27908850e+00 4.43106866e+00 0.29283079 0.83978748 577.25 4.07265954e+00 1.16039296e+00 4.23474528e+00 0.27756762 0.88812214 577.50 3.22473613e+00 1.02264300e+00 3.38300485e+00 0.30709242 0.88970522 577.75 2.98369397e+00 9.96273061e-01 3.14563026e+00 0.32226579 0.91757145 578.00 2.90558179e+00 1.15823288e+00 3.12792406e+00 0.37931909 0.94315030 578.25 2.93629689e+00 1.34920827e+00 3.23143968e+00 0.43072032 0.93775646 578.50 3.15114467e+00 1.28003713e+00 3.40120681e+00 0.38585124 0.93028837 578.75 2.97995631e+00 1.13418278e+00 3.18849654e+00 0.36367454 0.94077238 579.00 2.74013606e+00 1.13037027e+00 2.96413268e+00 0.39125558 0.94748024 579.25 2.74272806e+00 1.17977520e+00 2.98570372e+00 0.40622179 0.95328110 579.50 2.80947956e+00 1.32746761e+00 3.10730521e+00 0.44140325 0.96942027 579.75 2.85114045e+00 1.24558080e+00 3.11134591e+00 0.41188244 0.97173583 580.00 2.87513373e+00 1.12901963e+00 3.08886375e+00 0.37418380 0.97137293 580.25 2.88536273e+00 1.08460286e+00 3.08247976e+00 0.35955796 0.96984046 580.50 2.89968549e+00 1.16296932e+00 3.12420767e+00 0.38142621 0.95670342 580.75 2.96326528e+00 1.15109485e+00 3.17898734e+00 0.37051424 0.96148763 581.00 3.09671444e+00 9.57334279e-01 3.24131597e+00 0.29982559 0.97244301 581.25 3.22101868e+00 9.66102499e-01 3.36278387e+00 0.29139894 0.96960368 581.50 3.37908744e+00 8.47229502e-01 3.48368049e+00 0.24566307 0.96352726 581.75 3.46476751e+00 6.69254353e-01 3.52881217e+00 0.19081003 0.96026228 582.00 3.58722459e+00 4.53212619e-01 3.61574086e+00 0.12567489 0.95799851 582.25 3.48608128e+00 6.94061715e-02 3.48677213e+00 0.01990688 0.94671974 582.50 3.43123621e+00 -2.67633799e-01 3.44165799e+00 -0.07784163 0.95271340 582.75 3.16169956e+00 -2.86123581e-01 3.17461979e+00 -0.09025093 0.94951423 583.00 2.98974099e+00 -2.98679915e-01 3.00462325e+00 -0.09957123 0.96013201 583.25 2.88234606e+00 -2.87658748e-01 2.89666470e+00 -0.09947084 0.95054486 583.50 2.80947073e+00 -3.94049480e-01 2.83697035e+00 -0.13934853 0.95548577 583.75 2.83319041e+00 -4.36267964e-01 2.86658292e+00 -0.15278466 0.94358784 584.00 2.91865085e+00 -4.79141912e-01 2.95771867e+00 -0.16271417 0.95435831 584.25 2.76179381e+00 -4.66481883e-01 2.80091242e+00 -0.16732611 0.93440776 584.50 2.76777266e+00 -5.37961283e-01 2.81956873e+00 -0.19197256 0.93470727 584.75 3.00577584e+00 -6.39807084e-01 3.07311593e+00 -0.20972906 0.94109665 585.00 3.07893642e+00 -8.98451538e-01 3.20734542e+00 -0.28392234 0.94834817 585.25 2.72730297e+00 -1.44698906e+00 3.08738705e+00 -0.48779315 0.93497555 585.50 2.63948215e+00 -1.71954683e+00 3.15019163e+00 -0.57740882 0.93365188 585.75 2.19644538e+00 -1.97631849e+00 2.95469238e+00 -0.73269376 0.85087066 586.00 1.70424801e+00 -2.24776398e+00 2.82079850e+00 -0.92206972 0.83697390 586.25 9.67345850e-01 -2.38117812e+00 2.57016871e+00 -1.18491645 0.76296085 586.50 3.13979883e-01 -2.45865115e+00 2.47861834e+00 -1.44377971 0.75140563 586.75 -6.94879433e-01 -1.72684780e+00 1.86141364e+00 -1.95336790 0.42962642 587.00 -1.46293185e+00 -1.19735093e+00 1.89045466e+00 -2.45569664 0.44073600 587.25 -1.44684376e+00 2.56977104e-01 1.46948770e+00 2.96581354 0.30244258 587.50 -7.65770547e-01 1.71691732e+00 1.87994936e+00 1.99033123 0.40209306 587.75 4.51032337e-01 2.91404760e+00 2.94874610e+00 1.41723620 0.74951712 588.00 1.05766103e+00 2.77414554e+00 2.96892748e+00 1.20655182 0.80727514 588.25 2.00162395e+00 2.15838736e+00 2.94366004e+00 0.82306375 0.86977145 588.50 2.32114585e+00 1.78839330e+00 2.93019942e+00 0.65647913 0.91098464 588.75 2.35854612e+00 1.38340275e+00 2.73432678e+00 0.53047031 0.94119509 589.00 2.34995617e+00 1.31839806e+00 2.69452546e+00 0.51127278 0.94760938 589.25 2.41892243e+00 1.19074070e+00 2.69611742e+00 0.45743711 0.95942980 589.50 2.43580483e+00 1.07465482e+00 2.66233510e+00 0.41550414 0.96364865 589.75 2.64276993e+00 9.86210701e-01 2.82078791e+00 0.35716806 0.97253475 590.00 2.69337802e+00 8.31861578e-01 2.81891448e+00 0.29956015 0.96372145 590.25 2.71603780e+00 4.67592160e-01 2.75599415e+00 0.17048841 0.96088174 590.50 2.64688088e+00 3.17103637e-01 2.66580815e+00 0.11923448 0.95759598 590.75 2.39227640e+00 1.45464388e-01 2.39669486e+00 0.06073107 0.95991976 591.00 2.27164424e+00 -1.26221828e-03 2.27164459e+00 -0.00055564 0.95381149 591.25 2.05326153e+00 -1.20102954e-01 2.05677117e+00 -0.05842717 0.94388996 591.50 1.89680493e+00 -3.94421096e-02 1.89721496e+00 -0.02079098 0.91003328 591.75 1.62866775e+00 1.68895468e-01 1.63740169e+00 0.10333225 0.89935275 592.00 1.63671116e+00 3.60852450e-01 1.67601847e+00 0.21700249 0.91571187 592.25 1.67750271e+00 5.86864906e-01 1.77719604e+00 0.33653618 0.95708177 592.50 1.82351520e+00 6.74808424e-01 1.94436984e+00 0.35443192 0.93375484 592.75 2.11346773e+00 7.24850861e-01 2.23431301e+00 0.33039615 0.95001994 593.00 2.37088836e+00 6.01284928e-01 2.44594668e+00 0.24837497 0.95026564 593.25 2.56607712e+00 4.07539419e-01 2.59823790e+00 0.15750262 0.96166039 593.50 2.47004418e+00 1.87750672e-01 2.47716947e+00 0.07586517 0.92821267 593.75 2.39940264e+00 -2.02431510e-02 2.39948803e+00 -0.00843655 0.91833592 594.00 2.25401147e+00 -3.52079154e-01 2.28134334e+00 -0.15494904 0.88797070 594.25 2.13858398e+00 -6.06693664e-01 2.22297518e+00 -0.27642662 0.91397715 594.50 1.80258740e+00 -7.30216644e-01 1.94487472e+00 -0.38488970 0.84724714 594.75 1.55558717e+00 -9.32664800e-01 1.81375717e+00 -0.54009447 0.85727551 595.00 1.05519498e+00 -8.83121431e-01 1.37598689e+00 -0.69685553 0.73122654 595.25 6.52447975e-01 -7.50630869e-01 9.94552694e-01 -0.85526103 0.70372714 595.50 4.09733833e-01 -5.01862800e-01 6.47879683e-01 -0.88611948 0.46115609 595.75 2.19372830e-01 -2.25787822e-01 3.14808797e-01 -0.79980768 0.16563326 596.00 2.68971609e-01 9.52374349e-02 2.85334707e-01 0.34030482 0.13995684 596.25 4.45989275e-01 2.15058786e-01 4.95133027e-01 0.44931149 0.36981749 596.50 4.56500398e-01 1.65406645e-01 4.85542965e-01 0.34762225 0.27470083 596.75 3.12786962e-01 1.05428521e-01 3.30077046e-01 0.32510237 0.13904243 597.00 2.41120438e-01 -5.77444746e-02 2.47938480e-01 -0.23505698 0.06684736 597.25 1.86853107e-01 -2.54406872e-01 3.15653196e-01 -0.93731156 0.09203854 597.50 1.24310319e-01 -4.50330077e-01 4.67172595e-01 -1.30146101 0.12760695 597.75 -2.06562118e-01 -8.89683096e-01 9.13347645e-01 -1.79892940 0.31516513 598.00 -1.10934556e+00 -1.47995972e+00 1.84957518e+00 -2.21402744 0.51553550 598.25 -1.95180498e+00 -2.07621622e+00 2.84959936e+00 -2.32531787 0.63952774 598.50 -3.53963892e+00 -2.90680613e+00 4.58023640e+00 -2.45404867 0.76353464 598.75 -4.71097844e+00 -2.77124015e+00 5.46562803e+00 -2.60985654 0.71558856 599.00 -8.22384633e+00 -1.64691955e+00 8.38713255e+00 -2.94394569 0.73631191 599.25 -9.97569134e+00 -9.96623437e-02 9.97618917e+00 -3.13160247 0.74218295 599.50 -1.24667689e+01 4.73192363e+00 1.33345952e+01 2.77882760 0.74716934 599.75 -1.29433705e+01 8.21094825e+00 1.53280955e+01 2.57628029 0.77134280 600.00 -1.25140994e+01 1.12047804e+01 1.67973149e+01 2.41134007 0.79656099 600.25 -1.23240841e+01 1.21647498e+01 1.73165871e+01 2.36270081 0.77744968 600.50 -1.18479895e+01 1.82214071e+01 2.17346390e+01 2.14732874 0.78451902 600.75 -1.04701164e+01 2.12899995e+01 2.37252486e+01 2.02785089 0.78004111 601.00 -4.67112414e+00 2.92318475e+01 2.96027078e+01 1.72925240 0.80345644 601.25 1.19626695e+00 2.93531835e+01 2.93775499e+01 1.53006462 0.79594528 601.50 9.09485670e+00 2.85652832e+01 2.99781891e+01 1.26255591 0.83538156 601.75 1.27323250e+01 2.81125639e+01 3.08614379e+01 1.14552910 0.82289844 602.00 2.11367890e+01 2.60040974e+01 3.35108480e+01 0.88828384 0.86294553 602.25 2.57888905e+01 2.20797515e+01 3.39497025e+01 0.70806690 0.88488094 602.50 2.86981255e+01 1.56121150e+01 3.26698721e+01 0.49823402 0.93847296 602.75 2.61345040e+01 1.08989863e+01 2.83160767e+01 0.39510438 0.93821870 603.00 2.51395639e+01 8.21087992e+00 2.64464784e+01 0.31568909 0.97457331 603.25 2.38283230e+01 7.34762531e+00 2.49354481e+01 0.29910584 0.97036464 603.50 2.16657542e+01 6.49775658e+00 2.26191455e+01 0.29137339 0.97535504 603.75 2.12754700e+01 5.67829935e+00 2.20201886e+01 0.26081480 0.97675263 604.00 2.15547950e+01 5.24527333e+00 2.21838247e+01 0.23870635 0.97893014 604.25 2.09227502e+01 4.62333859e+00 2.14274762e+01 0.21747709 0.97956895 604.50 2.01541561e+01 4.59264216e+00 2.06708096e+01 0.22404987 0.98720254 604.75 2.00907834e+01 4.34906192e+00 2.05561163e+01 0.21318126 0.98836518 605.00 2.02185625e+01 4.29103343e+00 2.06688954e+01 0.20912931 0.99178404 605.25 2.06176166e+01 3.88607904e+00 2.09806511e+01 0.18629781 0.98984893 605.50 2.09569342e+01 3.67490950e+00 2.12767021e+01 0.17359039 0.98841876 605.75 2.19978256e+01 3.76982496e+00 2.23185105e+01 0.16972392 0.97919547 606.00 2.32081749e+01 3.79199809e+00 2.35159229e+01 0.16195949 0.98075918 606.25 2.39191675e+01 2.78776332e+00 2.40810755e+01 0.11602588 0.97402802 606.50 2.46043237e+01 1.44098560e+00 2.46464842e+01 0.05849953 0.97130771 606.75 2.53703338e+01 -1.92598793e-01 2.53710649e+01 -0.00759135 0.96567513 607.00 2.56996265e+01 -1.39747773e+00 2.57375941e+01 -0.05432385 0.96576418 607.25 2.49678492e+01 -3.81020591e+00 2.52569033e+01 -0.15143615 0.96426705 607.50 2.49706081e+01 -4.23493655e+00 2.53271782e+01 -0.16799831 0.97120392 607.75 2.51537601e+01 -6.05876072e+00 2.58731566e+01 -0.23636648 0.97268493 608.00 2.46299751e+01 -7.50952310e+00 2.57493420e+01 -0.29594032 0.97592395 608.25 2.38659471e+01 -9.14665506e+00 2.55586527e+01 -0.36598498 0.97170083 608.50 2.33170214e+01 -1.03414250e+01 2.55074217e+01 -0.41744708 0.97342663 608.75 2.14208439e+01 -1.06759064e+01 2.39338156e+01 -0.46235773 0.97786383 609.00 2.05892811e+01 -1.05437206e+01 2.31319809e+01 -0.47327875 0.97665931 609.25 1.92867343e+01 -9.45715325e+00 2.14805928e+01 -0.45589380 0.96032933 609.50 1.90479423e+01 -8.56124732e+00 2.08834639e+01 -0.42240299 0.94983264 609.75 2.18654454e+01 -6.35665465e+00 2.27706996e+01 -0.28291859 0.94812526 610.00 2.33069980e+01 -6.61558207e+00 2.42277131e+01 -0.27657089 0.93759617 610.25 2.52915616e+01 -9.49829563e+00 2.70163045e+01 -0.35925450 0.92539066 610.50 2.68486084e+01 -1.14608442e+01 2.91924429e+01 -0.40345282 0.91640896 610.75 2.77727209e+01 -1.79234179e+01 3.30540910e+01 -0.57310681 0.93314630 611.00 2.61293724e+01 -2.13745599e+01 3.37581977e+01 -0.68563740 0.91916600 611.25 2.35985645e+01 -2.54531393e+01 3.47095743e+01 -0.82318873 0.90605410 611.50 1.96938114e+01 -2.65079821e+01 3.30230120e+01 -0.93182965 0.85681448 611.75 1.03624023e+01 -2.47101231e+01 2.67949541e+01 -1.17371369 0.88073844 612.00 8.16210698e+00 -2.26359160e+01 2.40625161e+01 -1.22472549 0.88303142 612.25 7.80662928e+00 -1.81478901e+01 1.97557428e+01 -1.16455706 0.86623651 612.50 8.58775868e+00 -1.52386536e+01 1.74918885e+01 -1.05760883 0.83826247 612.75 1.05479045e+01 -1.28320678e+01 1.66108475e+01 -0.88278653 0.84309688 613.00 1.04867932e+01 -1.27607897e+01 1.65169787e+01 -0.88290444 0.80076559 613.25 1.10528608e+01 -1.43736610e+01 1.81319570e+01 -0.91526688 0.82182062 613.50 1.21677708e+01 -1.71058518e+01 2.09920178e+01 -0.95251197 0.86461952 613.75 1.13787373e+01 -2.06230878e+01 2.35539256e+01 -1.06661245 0.90038704 614.00 8.72321114e+00 -2.13672247e+01 2.30792700e+01 -1.18319650 0.89270333 614.25 6.02379120e+00 -2.26150871e+01 2.34035943e+01 -1.31047875 0.94201940 614.50 3.57930363e+00 -2.20729572e+01 2.23612803e+01 -1.41003777 0.93428982 614.75 1.82338428e+00 -2.15046003e+01 2.15817646e+01 -1.48620822 0.92886758 615.00 4.44400784e-01 -1.96169319e+01 1.96219650e+01 -1.54814626 0.91951371 615.25 -3.89077020e-01 -1.88115604e+01 1.88155836e+01 -1.59147625 0.94609384 615.50 -1.72313865e+00 -1.69755924e+01 1.70628234e+01 -1.67195667 0.91599512 615.75 -3.03103447e+00 -1.63293524e+01 1.66082787e+01 -1.75432633 0.93921724 616.00 -3.66886208e+00 -1.55229663e+01 1.59506436e+01 -1.80288780 0.94302274 616.25 -4.53474858e+00 -1.49518573e+01 1.56244034e+01 -1.86526872 0.95541522 616.50 -4.38647291e+00 -1.32632908e+01 1.39698256e+01 -1.89019558 0.92367907 616.75 -4.64076087e+00 -1.20300313e+01 1.28941194e+01 -1.93897094 0.92209595 617.00 -4.88720192e+00 -1.05613549e+01 1.16373090e+01 -2.00419735 0.92726756 617.25 -4.57188270e+00 -9.68635267e+00 1.07110942e+01 -2.01178769 0.92926751 617.50 -3.54060593e+00 -8.84900055e+00 9.53103882e+00 -1.95140068 0.87171036 617.75 -3.60895694e+00 -8.63900407e+00 9.36252966e+00 -1.96651145 0.86212348 618.00 -5.45897221e+00 -7.71062330e+00 9.44743824e+00 -2.18685838 0.86119937 618.25 -6.08547808e+00 -6.50386882e+00 8.90692726e+00 -2.32297300 0.88272155 618.50 -5.90985601e+00 -5.10261425e+00 7.80788513e+00 -2.42936614 0.88574505 618.75 -5.86374295e+00 -4.28373956e+00 7.26181148e+00 -2.51065818 0.88704051 619.00 -5.61854605e+00 -3.40306869e+00 6.56878499e+00 -2.59700354 0.87287871 619.25 -5.40106015e+00 -2.68779989e+00 6.03288645e+00 -2.67983241 0.87672332 619.50 -5.04055599e+00 -1.29647013e+00 5.20461713e+00 -2.88984180 0.87523392 619.75 -4.47121372e+00 -7.23017337e-01 4.52929423e+00 -2.98127545 0.86674285 620.00 -3.42483630e+00 -2.73626403e-01 3.43574957e+00 -3.06186726 0.88731974 620.25 -3.11080312e+00 7.88340075e-02 3.11180187e+00 3.11625607 0.84137340 620.50 -2.04859839e+00 4.63660186e-01 2.10041333e+00 2.91901224 0.78785566 620.75 -1.63584737e+00 5.15979276e-01 1.71529334e+00 2.83604962 0.72690134 621.00 -9.39334442e-01 4.25400121e-01 1.03117140e+00 2.71635130 0.50205280 621.25 -7.07046942e-01 2.67192120e-01 7.55848534e-01 2.78028308 0.27528807 621.50 -3.91534051e-01 -2.60512320e-01 4.70282449e-01 -2.55449304 0.16368063 621.75 -2.40140160e-01 -5.64606427e-01 6.13553350e-01 -1.97294062 0.23145821 622.00 6.17403485e-02 -1.12353804e+00 1.12523313e+00 -1.51589982 0.42873636 622.25 6.04467425e-02 -1.64042217e+00 1.64153547e+00 -1.53396471 0.49456183 622.50 -3.04740822e-01 -2.75175546e+00 2.76857817e+00 -1.68109105 0.69670280 622.75 -1.03054753e+00 -2.93553731e+00 3.11117462e+00 -1.90841449 0.72952972 623.00 -2.20438915e+00 -2.97783924e+00 3.70497747e+00 -2.20803765 0.78775202 623.25 -3.21958099e+00 -2.74483988e+00 4.23082117e+00 -2.43562254 0.75510575 623.50 -5.06565359e+00 -2.94094052e+00 5.85747193e+00 -2.61558628 0.79997746 623.75 -6.19030194e+00 -1.26994026e+00 6.31922356e+00 -2.93925014 0.73273608 624.00 -8.15943809e+00 4.06228135e-01 8.16954413e+00 3.09184744 0.89392312 624.25 -8.15276619e+00 2.25406477e+00 8.45862899e+00 2.87185239 0.84397208 624.50 -7.83673853e+00 5.36644163e+00 9.49806120e+00 2.54115467 0.89367780 624.75 -6.92594270e+00 7.01484264e+00 9.85782428e+00 2.34981761 0.91371203 625.00 -5.59737687e+00 7.89298069e+00 9.67624782e+00 2.18764274 0.93621211 625.25 -3.83901764e+00 8.57742331e+00 9.39735319e+00 1.99162960 0.92393660 625.50 -2.59779498e+00 9.00163459e+00 9.36898948e+00 1.85175400 0.95572882 625.75 -1.95825636e+00 8.69104221e+00 8.90892713e+00 1.79241431 0.96197251 626.00 -1.40305362e+00 8.51889232e+00 8.63366005e+00 1.73402998 0.96886727 626.25 -7.49358358e-01 8.62964808e+00 8.66212237e+00 1.65741438 0.94395605 626.50 -1.74731734e-01 9.19071423e+00 9.19237505e+00 1.58980581 0.95114899 626.75 5.97758231e-01 9.65200839e+00 9.67050055e+00 1.50894435 0.94613753 627.00 1.27565787e+00 9.68617080e+00 9.76981104e+00 1.43985104 0.94240647 627.25 2.91040785e+00 1.00288419e+01 1.04426120e+01 1.28835094 0.91654243 627.50 4.20182626e+00 1.04602547e+01 1.12726338e+01 1.18883007 0.94046136 627.75 5.80714858e+00 1.01200223e+01 1.16678115e+01 1.04984355 0.93084393 628.00 6.32200699e+00 8.73659979e+00 1.07840599e+01 0.94439112 0.89494893 628.25 7.41146839e+00 5.79234222e+00 9.40643886e+00 0.66338165 0.86278031 628.50 7.61150824e+00 4.70500151e+00 8.94830134e+00 0.55365333 0.88124949 628.75 6.31159119e+00 3.72482609e+00 7.32874564e+00 0.53315014 0.84972497 629.00 6.23734697e+00 2.95908523e+00 6.90367168e+00 0.44297017 0.81790359 629.25 5.53028382e+00 2.42876699e+00 6.04011161e+00 0.41381617 0.80863836 629.50 5.11446939e+00 2.46300681e+00 5.67663630e+00 0.44880025 0.83191417 629.75 4.58541405e+00 2.18838933e+00 5.08085327e+00 0.44528262 0.84415750 630.00 4.80650346e+00 1.91290701e+00 5.17317009e+00 0.37876644 0.85108085 630.25 4.52183934e+00 1.95074527e+00 4.92467644e+00 0.40728343 0.85672089 630.50 4.26150326e+00 1.98856008e+00 4.70263556e+00 0.43659990 0.84127670 630.75 4.35614585e+00 2.06894968e+00 4.82250551e+00 0.44340721 0.87949289 631.00 4.41065324e+00 1.68305078e+00 4.72086029e+00 0.36453359 0.86930397 631.25 4.06992453e+00 1.53686304e+00 4.35042914e+00 0.36106097 0.87874175 631.50 3.89518680e+00 1.50913557e+00 4.17731617e+00 0.36962864 0.86972708 631.75 3.60401740e+00 1.10673930e+00 3.77012112e+00 0.29794396 0.85858652 632.00 3.50531649e+00 1.20119416e+00 3.70541645e+00 0.33013687 0.89921756 632.25 3.26678830e+00 1.52021243e+00 3.60318631e+00 0.43554855 0.92517044 632.50 3.11430130e+00 1.68550107e+00 3.54115609e+00 0.49607211 0.92373216 632.75 3.10965500e+00 1.92331321e+00 3.65637634e+00 0.55390954 0.95326805 633.00 3.29801247e+00 2.06201668e+00 3.88957568e+00 0.55876477 0.96796637 633.25 3.55727892e+00 2.13493139e+00 4.14875467e+00 0.54053608 0.98134582 633.50 3.70513823e+00 2.27757180e+00 4.34918183e+00 0.55116283 0.97516317 633.75 3.87425562e+00 2.49913123e+00 4.61037021e+00 0.57289533 0.98068835 634.00 4.09514522e+00 2.44681604e+00 4.77044265e+00 0.53857326 0.98086019 634.25 4.47278372e+00 2.47954627e+00 5.11409268e+00 0.50618683 0.98858938 634.50 4.71460920e+00 2.29753297e+00 5.24463514e+00 0.45345390 0.98683117 634.75 4.94251441e+00 2.16158709e+00 5.39452569e+00 0.41228087 0.99096149 635.00 5.18162896e+00 1.94914884e+00 5.53610512e+00 0.35979188 0.98519372 635.25 5.37090107e+00 1.65436023e+00 5.61991868e+00 0.29880085 0.98889075 635.50 5.43175687e+00 1.40263181e+00 5.60993393e+00 0.25270756 0.98495006 635.75 5.55985869e+00 1.02346820e+00 5.65327479e+00 0.18204370 0.98790762 636.00 5.35313252e+00 8.50491155e-01 5.42027333e+00 0.15756038 0.97355497 636.25 5.07549511e+00 8.81580883e-01 5.15148867e+00 0.17197778 0.96677719 636.50 5.11102794e+00 1.26681122e+00 5.26568298e+00 0.24296203 0.95469325 636.75 5.44407910e+00 1.49041102e+00 5.64440628e+00 0.26721985 0.96273719 637.00 5.84433477e+00 1.75344394e+00 6.10170587e+00 0.29147932 0.95366244 637.25 6.29368108e+00 1.81763917e+00 6.55089564e+00 0.28115369 0.95389099 637.50 7.29883839e+00 1.39238421e+00 7.43046268e+00 0.18850300 0.91878034 637.75 8.32517050e+00 6.75924929e-01 8.35256478e+00 0.08101282 0.92200358 638.00 8.44563134e+00 -5.74228548e-01 8.46513007e+00 -0.06788671 0.89818120 638.25 8.74540918e+00 -1.53814880e+00 8.87964434e+00 -0.17410008 0.89510477 638.50 7.61679314e+00 -3.67987082e+00 8.45913630e+00 -0.45005751 0.91013520 638.75 7.10808333e+00 -4.16637864e+00 8.23914799e+00 -0.53017087 0.92700212 639.00 6.12697066e+00 -4.09917296e+00 7.37176969e+00 -0.58964213 0.88487438 639.25 5.97974796e+00 -4.40372310e+00 7.42631556e+00 -0.63476581 0.91000738 639.50 5.57216549e+00 -5.18827888e+00 7.61362371e+00 -0.74973757 0.87965824 639.75 5.42452306e+00 -5.49462286e+00 7.72116123e+00 -0.79181797 0.85312413 640.00 5.00480313e+00 -6.21943822e+00 7.98307373e+00 -0.89319403 0.70045348 640.25 4.28876651e+00 -7.22047834e+00 8.39814417e+00 -1.03482050 0.60287497 640.50 8.00609541e-01 -7.26953098e+00 7.31348455e+00 -1.46110617 0.41453505 640.75 -1.82929238e+00 -5.79694500e+00 6.07872371e+00 -1.87646784 0.39709388 641.00 -3.10704683e+00 -3.43700699e+00 4.63322318e+00 -2.30581578 0.54436012 641.25 -2.92761103e+00 -2.42349380e+00 3.80055634e+00 -2.45012532 0.55583592 641.50 -2.19487281e+00 -1.36488553e+00 2.58464295e+00 -2.58526044 0.63900760 641.75 -1.70627084e+00 -1.15029180e+00 2.05779771e+00 -2.54842341 0.66180033 642.00 -9.03267843e-01 -8.93091810e-01 1.27023847e+00 -2.36185924 0.54223082 642.25 -4.18032726e-01 -5.61414203e-01 6.99955190e-01 -2.21083672 0.32130204 642.50 1.98032929e-01 -4.57511548e-01 4.98531702e-01 -1.16229723 0.29097346 642.75 5.33716242e-01 -6.35394858e-01 8.29806997e-01 -0.87215075 0.49896993 643.00 9.27847098e-01 -8.65865267e-01 1.26910319e+00 -0.75085685 0.82074673 643.25 1.06010756e+00 -9.04205845e-01 1.39334714e+00 -0.70619716 0.85287734 643.50 1.19782540e+00 -9.65147771e-01 1.53827693e+00 -0.67823720 0.87980859 643.75 1.27368832e+00 -1.01960923e+00 1.63152840e+00 -0.67505614 0.88018856 644.00 1.51372706e+00 -1.10461399e+00 1.87391080e+00 -0.63040244 0.90043912 644.25 1.80346984e+00 -1.23710478e+00 2.18699147e+00 -0.60123958 0.89600330 644.50 1.97017191e+00 -1.51446754e+00 2.48499281e+00 -0.65536093 0.92275372 644.75 2.02039372e+00 -1.70498898e+00 2.64366757e+00 -0.70093587 0.93195675 645.00 2.00451937e+00 -1.89932799e+00 2.76143889e+00 -0.75845912 0.94639300 645.25 1.84705207e+00 -2.15141047e+00 2.83551906e+00 -0.86137052 0.95829040 645.50 1.84962434e+00 -2.36791874e+00 3.00468790e+00 -0.90767521 0.97572852 645.75 1.80619574e+00 -2.52425456e+00 3.10390143e+00 -0.94971925 0.96643891 646.00 1.64752349e+00 -2.75504655e+00 3.21008024e+00 -1.03184720 0.97181724 646.25 1.40025479e+00 -2.92664121e+00 3.24437086e+00 -1.12453595 0.96340036 646.50 1.03647748e+00 -3.14747149e+00 3.31373842e+00 -1.25267582 0.96054616 646.75 5.56480981e-01 -3.11184862e+00 3.16121384e+00 -1.39384030 0.96388184 647.00 4.15871864e-01 -2.98243881e+00 3.01129386e+00 -1.43224947 0.97955086 647.25 2.01626375e-01 -2.72068805e+00 2.72814895e+00 -1.49682295 0.97025679 647.50 6.32491807e-02 -2.55862673e+00 2.55940837e+00 -1.54608139 0.97544002 647.75 -5.98476736e-04 -2.22756595e+00 2.22756603e+00 -1.57106500 0.96745340 648.00 -8.68951049e-04 -2.05358026e+00 2.05358045e+00 -1.57121947 0.97419146 648.25 9.03377231e-02 -1.78430794e+00 1.78659333e+00 -1.52021052 0.95838504 648.50 1.80909555e-01 -1.60431206e+00 1.61447993e+00 -1.45850611 0.96391511 648.75 4.38875693e-01 -1.51818856e+00 1.58035071e+00 -1.28938911 0.95585962 649.00 6.14912841e-01 -1.42366355e+00 1.55078551e+00 -1.16307659 0.96958202 649.25 8.18714489e-01 -1.40747935e+00 1.62827871e+00 -1.04395002 0.97211410 649.50 9.76785265e-01 -1.40799786e+00 1.71364157e+00 -0.96428367 0.97493861 649.75 1.23315447e+00 -1.53562564e+00 1.96947101e+00 -0.89421015 0.97664618 650.00 1.38203869e+00 -1.60900282e+00 2.12106601e+00 -0.86113433 0.98256732 650.25 1.52964894e+00 -1.83456346e+00 2.38860817e+00 -0.87578594 0.98006797 650.50 1.58158479e+00 -2.04637007e+00 2.58631802e+00 -0.91281629 0.98284432 650.75 1.62219268e+00 -2.31632184e+00 2.82787128e+00 -0.95984805 0.98640412 651.00 1.60821260e+00 -2.46318329e+00 2.94170353e+00 -0.99238508 0.98487722 651.25 1.45798330e+00 -2.68959188e+00 3.05934956e+00 -1.07405138 0.98438107 651.50 1.36995633e+00 -2.82508969e+00 3.13973121e+00 -1.11928137 0.98557419 651.75 1.17381205e+00 -2.99202375e+00 3.21403809e+00 -1.19693354 0.98052460 652.00 9.56257614e-01 -2.97146139e+00 3.12153991e+00 -1.25944883 0.97493264 652.25 8.73310882e-01 -2.84008769e+00 2.97132462e+00 -1.27247825 0.98439955 652.50 8.69584307e-01 -2.79155956e+00 2.92386417e+00 -1.26881834 0.97979747 652.75 9.28073859e-01 -2.78507011e+00 2.93563224e+00 -1.24913718 0.97850942 653.00 9.46087814e-01 -2.89578115e+00 3.04641274e+00 -1.25501634 0.97474147 653.25 8.59154448e-01 -3.06522879e+00 3.18335890e+00 -1.29751828 0.98216757 653.50 6.97634398e-01 -3.16218225e+00 3.23822333e+00 -1.35365661 0.97139111 653.75 4.05573758e-01 -3.29981471e+00 3.32464542e+00 -1.44850164 0.96694393 654.00 1.73143646e-01 -3.11579779e+00 3.12060484e+00 -1.51528382 0.95589972 654.25 -1.29136982e-01 -2.82600011e+00 2.82894909e+00 -1.61646059 0.95149795 654.50 -1.92013886e-01 -2.53959235e+00 2.54684092e+00 -1.64626090 0.93699623 654.75 -1.83164572e-01 -2.26159470e+00 2.26899975e+00 -1.65160907 0.95500145 655.00 -6.60936538e-02 -2.08660999e+00 2.08765649e+00 -1.60246088 0.91965998 655.25 1.82142316e-01 -1.89496910e+00 1.90370264e+00 -1.47497182 0.91535426 655.50 3.22274459e-01 -1.92471117e+00 1.95150556e+00 -1.40489490 0.91279180 655.75 3.98295678e-01 -1.99687417e+00 2.03620870e+00 -1.37392046 0.95085158 656.00 3.05091899e-01 -1.98806018e+00 2.01133397e+00 -1.41852219 0.94629907 656.25 1.66297101e-01 -1.95108087e+00 1.95815507e+00 -1.48576851 0.94924283 656.50 4.40179001e-02 -1.76332138e+00 1.76387070e+00 -1.54583845 0.90996204 656.75 -5.76466496e-02 -1.57799094e+00 1.57904356e+00 -1.60731176 0.90069416 657.00 -7.59947951e-02 -1.19989071e+00 1.20229486e+00 -1.63404661 0.72370262 657.25 -9.95555593e-02 -7.84985403e-01 7.91273273e-01 -1.69694757 0.61454560 657.50 1.68081766e-01 -4.35249367e-01 4.66576352e-01 -1.20226589 0.38284289 657.75 3.85224615e-01 -2.39110893e-01 4.53400511e-01 -0.55550490 0.44402936 658.00 8.02168226e-01 -1.43854970e-01 8.14965101e-01 -0.17744648 0.71261335 658.25 1.04304521e+00 -1.32405354e-01 1.05141547e+00 -0.12626582 0.82315960 658.50 1.33751000e+00 -2.57843135e-01 1.36213659e+00 -0.19044224 0.86800232 658.75 1.48023169e+00 -4.00548525e-01 1.53346828e+00 -0.26426962 0.91484910 659.00 1.42628457e+00 -6.35812743e-01 1.56158430e+00 -0.41934114 0.88339082 659.25 1.37072722e+00 -7.08271349e-01 1.54290033e+00 -0.47692773 0.89027655 659.50 1.16305585e+00 -7.03235977e-01 1.35913198e+00 -0.54382799 0.79243411 659.75 9.64539936e-01 -6.57748328e-01 1.16746313e+00 -0.59849495 0.66074889 660.00 1.00294200e+00 -7.46267676e-02 1.00571458e+00 -0.07427099 0.51138820 660.25 1.05127173e+00 2.65577567e-01 1.08429871e+00 0.24744776 0.60766099 660.50 1.34833058e+00 6.24052085e-01 1.48574438e+00 0.43347457 0.79305282 660.75 1.56100265e+00 6.83925088e-01 1.70425432e+00 0.41294072 0.88233453 661.00 1.80399589e+00 8.41208124e-01 1.99048544e+00 0.43632823 0.91477062 661.25 1.99680162e+00 7.92575698e-01 2.14834656e+00 0.37785064 0.92060645 661.50 2.20056805e+00 6.18491583e-01 2.28583279e+00 0.27399134 0.94924352 661.75 2.30053466e+00 4.95634093e-01 2.35331955e+00 0.21219955 0.95336200 662.00 2.44097046e+00 2.30216879e-01 2.45180272e+00 0.09403551 0.95871405 662.25 2.52743007e+00 1.12853236e-01 2.52994834e+00 0.04462174 0.96636112 662.50 2.45912284e+00 -1.56124720e-01 2.46407388e+00 -0.06340288 0.97185085 662.75 2.39561231e+00 -2.34993858e-01 2.40711039e+00 -0.09778062 0.96901030 663.00 2.18078151e+00 -3.92534440e-01 2.21582745e+00 -0.17809017 0.96961644 663.25 2.15212066e+00 -4.20395950e-01 2.19279641e+00 -0.19291112 0.97338349 663.50 2.04827791e+00 -5.59417560e-01 2.12329706e+00 -0.26661387 0.97356474 663.75 2.00027860e+00 -5.93316115e-01 2.08641762e+00 -0.28835000 0.96687165 664.00 1.85839756e+00 -6.32823790e-01 1.96318808e+00 -0.32820564 0.96379759 664.25 1.77750416e+00 -6.78535494e-01 1.90261174e+00 -0.36466219 0.94942122 664.50 1.59805708e+00 -6.88357627e-01 1.74000651e+00 -0.40672797 0.93372274 664.75 1.52037486e+00 -6.12696890e-01 1.63918797e+00 -0.38308188 0.90314804 665.00 1.38461875e+00 -5.22145642e-01 1.47979903e+00 -0.36061423 0.88640853 665.25 1.36220426e+00 -4.88016991e-01 1.44698343e+00 -0.34401025 0.86446946 665.50 1.37331823e+00 -4.99872143e-01 1.46146335e+00 -0.34908204 0.85553301 665.75 1.31791803e+00 -5.37400435e-01 1.42327339e+00 -0.38718210 0.81417144 666.00 1.35317339e+00 -6.76348367e-01 1.51278728e+00 -0.46350670 0.90039536 666.25 1.34697626e+00 -7.14096624e-01 1.52455863e+00 -0.48747403 0.87694210 666.50 1.20467151e+00 -7.96808628e-01 1.44434671e+00 -0.58437004 0.89280981 666.75 9.74903563e-01 -8.43816954e-01 1.28936574e+00 -0.71344631 0.81799869 667.00 7.06712574e-01 -8.10086358e-01 1.07502678e+00 -0.85344553 0.81804616 667.25 4.94071947e-01 -6.23775187e-01 7.95740267e-01 -0.90091113 0.67492756 667.50 3.56544677e-01 -4.11927979e-01 5.44801585e-01 -0.85734309 0.54576718 667.75 4.57975297e-01 -1.11639534e-01 4.71385997e-01 -0.23910432 0.35057942 668.00 5.52228259e-01 2.02927363e-01 5.88332869e-01 0.35215281 0.48207529 668.25 8.40802943e-01 4.99648645e-01 9.78058463e-01 0.53618215 0.68051187 668.50 1.09261527e+00 6.12336838e-01 1.25250331e+00 0.51081732 0.82868340 668.75 1.51796494e+00 4.38823812e-01 1.58012148e+00 0.28141497 0.82163783 669.00 1.86899142e+00 2.87122593e-01 1.89091732e+00 0.15243265 0.88533644 669.25 2.27840342e+00 -1.07872321e-01 2.28095563e+00 -0.04731025 0.87069905 669.50 2.23683799e+00 -6.10550664e-01 2.31866692e+00 -0.26646173 0.89404244 669.75 2.17241859e+00 -1.47761704e+00 2.62730940e+00 -0.59729387 0.88137871 670.00 1.89146334e+00 -1.96746247e+00 2.72920173e+00 -0.80508999 0.84531781 670.25 7.59006763e-01 -2.13633266e+00 2.26715869e+00 -1.22942113 0.73647789 670.50 2.12295813e-01 -1.79656790e+00 1.80906764e+00 -1.45317435 0.63813518 670.75 -2.13583717e-01 -1.11140397e+00 1.13174060e+00 -1.76065636 0.42789631 671.00 -2.63705749e-01 -7.02056318e-01 7.49949196e-01 -1.93010964 0.26716900 671.25 -1.36250120e-01 -8.08948519e-02 1.58455269e-01 -2.60580126 0.02019390 671.50 2.24431129e-03 2.45127685e-01 2.45137959e-01 1.56164090 0.05783332 671.75 3.77977253e-01 3.46102714e-01 5.12497700e-01 0.74140582 0.24807521 672.00 5.84912144e-01 3.31540793e-01 6.72340325e-01 0.51566622 0.33233447 672.25 9.76722158e-01 3.00976050e-01 1.02204342e+00 0.29891616 0.57051929 672.50 1.02886614e+00 3.53416867e-01 1.08787362e+00 0.33087365 0.58084402 672.75 1.16885184e+00 3.46928717e-01 1.21925147e+00 0.28852904 0.66800156 673.00 1.34384990e+00 2.67211481e-01 1.37015857e+00 0.19628019 0.71680646 673.25 1.67333821e+00 4.86127692e-02 1.67404419e+00 0.02904320 0.80029771 673.50 1.83299680e+00 -6.56382706e-02 1.83417165e+00 -0.03579397 0.86279917 673.75 1.99760993e+00 -2.52983079e-01 2.01356547e+00 -0.12597227 0.92564857 674.00 2.06279943e+00 -4.96141395e-01 2.12162621e+00 -0.23603517 0.93086680 674.25 2.05961039e+00 -8.90265447e-01 2.24378420e+00 -0.40799493 0.94992859 674.50 1.93684448e+00 -1.00224730e+00 2.18079485e+00 -0.47752100 0.93565518 674.75 1.76762095e+00 -1.20084771e+00 2.13694151e+00 -0.59673763 0.96538692 675.00 1.69939904e+00 -1.27412651e+00 2.12399516e+00 -0.64334187 0.96567353 675.25 1.54189704e+00 -1.43135380e+00 2.10385840e+00 -0.74823603 0.96965304 675.50 1.51039783e+00 -1.51785608e+00 2.14130537e+00 -0.78786105 0.96933127 675.75 1.49131415e+00 -1.55948189e+00 2.15777701e+00 -0.80773869 0.97346006 676.00 1.42166930e+00 -1.65627711e+00 2.18274997e+00 -0.86147325 0.96348677 676.25 1.23981191e+00 -1.77239972e+00 2.16299199e+00 -0.96039908 0.95722466 676.50 1.18058326e+00 -1.79693857e+00 2.15006164e+00 -0.98951801 0.94912514 676.75 1.09608133e+00 -1.76626612e+00 2.07872323e+00 -1.01539324 0.96843899 677.00 1.06678530e+00 -1.83514922e+00 2.12268781e+00 -1.04423500 0.95950427 677.25 1.09146941e+00 -1.95377658e+00 2.23797864e+00 -1.06133938 0.96440287 677.50 1.09266824e+00 -2.04267990e+00 2.31656320e+00 -1.07960532 0.93679901 677.75 9.78029393e-01 -2.20220540e+00 2.40961617e+00 -1.15284829 0.92746248 678.00 8.87008589e-01 -2.21886431e+00 2.38959056e+00 -1.19049865 0.89711504 678.25 8.85117359e-01 -2.28030585e+00 2.44606368e+00 -1.20054068 0.91250873 678.50 7.63736396e-01 -2.32945040e+00 2.45145517e+00 -1.25397875 0.85985594 678.75 7.27668165e-01 -2.40238550e+00 2.51017072e+00 -1.27668660 0.82989017 679.00 9.34012214e-01 -2.37162460e+00 2.54891782e+00 -1.19562192 0.80018255 679.25 1.05141587e+00 -2.36124982e+00 2.58475841e+00 -1.15187499 0.79422810 679.50 9.67678628e-01 -2.24536412e+00 2.44500756e+00 -1.16388216 0.61691257 679.75 8.46208362e-01 -2.08856008e+00 2.25347549e+00 -1.18584658 0.43227993 680.00 2.15141470e-01 -1.88212272e+00 1.89437900e+00 -1.45698243 0.25329507 680.25 -6.37905716e-01 -1.80350292e+00 1.91299411e+00 -1.91076687 0.22749366 680.50 -1.97458514e+00 -1.90201472e+00 2.74165032e+00 -2.37491242 0.37535507 680.75 -2.38537089e+00 -1.90843013e+00 3.05484858e+00 -2.46681761 0.44171628 681.00 -1.98445980e+00 -1.74564609e+00 2.64298335e+00 -2.42013054 0.36284668 681.25 -2.31265833e+00 -1.74363500e+00 2.89631690e+00 -2.49556661 0.44316403 681.50 -2.61927925e+00 -7.69028920e-01 2.72984052e+00 -2.85601471 0.38727944 681.75 -2.86178406e+00 -2.94333230e-01 2.87688027e+00 -3.03910346 0.41405248 682.00 -2.44591648e+00 -2.33465980e-01 2.45703354e+00 -3.04642963 0.34584667 682.25 -2.62253425e+00 -2.43858954e-01 2.63384759e+00 -3.04887328 0.43720686 682.50 -2.61576113e+00 3.46928186e-01 2.63866737e+00 3.00973231 0.41916767 682.75 -3.06403418e+00 6.43512924e-01 3.13088076e+00 2.93457991 0.50706781 683.00 -2.97351616e+00 1.82562468e+00 3.48922683e+00 2.59097048 0.41631060 683.25 -2.27531542e+00 2.68185631e+00 3.51701770e+00 2.27436696 0.41108879 683.50 -1.86789200e+00 2.95880658e+00 3.49907943e+00 2.13391253 0.47388357 683.75 -1.06962393e+00 2.32268040e+00 2.55713504e+00 2.00235818 0.33374078 684.00 5.46040720e-01 2.08987556e+00 2.16003248e+00 1.31523057 0.35082202 684.25 1.25724887e+00 1.48656979e+00 1.94693720e+00 0.86878166 0.39222917 684.50 1.35541223e+00 1.44170885e+00 1.97880437e+00 0.81624032 0.52858981 684.75 1.19388256e+00 6.54018217e-01 1.36128447e+00 0.50115861 0.39419661 685.00 9.25069988e-01 -5.37377323e-02 9.26629498e-01 -0.05802524 0.40893700 685.25 9.41417753e-01 -1.56777587e-01 9.54382836e-01 -0.16501910 0.43791065 685.50 6.81643752e-01 -3.59171013e-01 7.70481682e-01 -0.48495014 0.37699966 685.75 5.09229503e-01 -5.34707801e-01 7.38394962e-01 -0.80979929 0.37381984 686.00 4.51421585e-01 -8.47376691e-01 9.60119109e-01 -1.08131013 0.55637697 686.25 3.98635548e-01 -1.13383071e+00 1.20186620e+00 -1.23271200 0.63300901 686.50 1.35947769e-01 -1.40344355e+00 1.41001262e+00 -1.47423032 0.73438324 686.75 -1.74473616e-01 -1.42207584e+00 1.43273890e+00 -1.69287561 0.76742313 687.00 -4.53297363e-01 -1.48188768e+00 1.54966757e+00 -1.86764968 0.80472566 687.25 -8.37723982e-01 -1.42758818e+00 1.65523095e+00 -2.10146134 0.80521355 687.50 -1.05522874e+00 -1.31990268e+00 1.68986709e+00 -2.24521685 0.84025677 687.75 -1.26125660e+00 -1.09672431e+00 1.67139835e+00 -2.42585835 0.82945221 688.00 -1.42874861e+00 -8.87260634e-01 1.68183056e+00 -2.58587100 0.90107602 688.25 -1.42849353e+00 -6.77185911e-01 1.58087777e+00 -2.69891483 0.87597693 688.50 -1.41106945e+00 -4.20877343e-01 1.47249948e+00 -2.85172529 0.88768851 688.75 -1.39076677e+00 -3.35392205e-01 1.43063627e+00 -2.90495461 0.91366477 689.00 -1.36868528e+00 -2.79865637e-01 1.39700543e+00 -2.93989533 0.92526808 689.25 -1.31101115e+00 -8.70042797e-02 1.31389497e+00 -3.07532557 0.89546072 689.50 -1.27084818e+00 -5.24955691e-02 1.27193194e+00 -3.10030862 0.91750078 689.75 -1.15988390e+00 -9.19254448e-02 1.16352092e+00 -3.06250396 0.89950366 690.00 -1.08192202e+00 -1.14526385e-01 1.08796670e+00 -3.03613082 0.93186471 690.25 -1.05471456e+00 -2.24310543e-01 1.07830331e+00 -2.93204062 0.92857436 690.50 -1.05194955e+00 -2.57475597e-01 1.08300117e+00 -2.90155142 0.92652345 690.75 -1.08069525e+00 -2.54167725e-01 1.11018172e+00 -2.91060151 0.91479364 691.00 -1.11761826e+00 -2.13457530e-01 1.13782015e+00 -2.95287225 0.91187774 691.25 -1.13417841e+00 -2.06409236e-01 1.15280763e+00 -2.96157275 0.94945084 691.50 -1.18734544e+00 -2.21560239e-01 1.20784028e+00 -2.95711299 0.94988512 691.75 -1.22687814e+00 -1.91386513e-01 1.24171606e+00 -2.98684512 0.93661736 692.00 -1.26872697e+00 -1.50541549e-01 1.27762705e+00 -3.02348926 0.95366757 692.25 -1.29601955e+00 -1.03458106e-01 1.30014239e+00 -3.06193399 0.97299356 692.50 -1.32754521e+00 -7.58000779e-02 1.32970746e+00 -3.08455666 0.97925891 692.75 -1.33601989e+00 2.78292224e-02 1.33630970e+00 3.12076572 0.97868298 693.00 -1.32129313e+00 9.20400699e-02 1.32449497e+00 3.07204591 0.97565603 693.25 -1.29657132e+00 1.79700493e-01 1.30896503e+00 3.00387331 0.98432646 693.50 -1.27174886e+00 2.13347395e-01 1.28952017e+00 2.97538129 0.98207555 693.75 -1.18030926e+00 3.00475787e-01 1.21795552e+00 2.89231391 0.98459757 694.00 -1.13785303e+00 2.93523604e-01 1.17510239e+00 2.88913387 0.98403437 694.25 -1.04471750e+00 2.83517313e-01 1.08250483e+00 2.87659336 0.98278014 694.50 -1.01700162e+00 2.68362625e-01 1.05181310e+00 2.88359718 0.97993697 694.75 -9.94028603e-01 1.99643645e-01 1.01387891e+00 2.94338669 0.97998586 695.00 -1.00805753e+00 1.80180741e-01 1.02403373e+00 2.96471992 0.98219395 695.25 -1.04918056e+00 1.50929217e-01 1.05998089e+00 2.99871845 0.98727645 695.50 -1.07653214e+00 1.41957008e-01 1.08585139e+00 3.01048399 0.97863094 695.75 -1.19889583e+00 1.61777022e-01 1.20976156e+00 3.00746448 0.97700756 696.00 -1.22704343e+00 2.43879923e-01 1.25104476e+00 2.94539535 0.97358881 696.25 -1.27353904e+00 4.05106382e-01 1.33641792e+00 2.83361872 0.97645889 696.50 -1.26243049e+00 5.33408552e-01 1.37049459e+00 2.74182015 0.96861141 696.75 -1.20321606e+00 6.65517616e-01 1.37500640e+00 2.63636055 0.96380815 697.00 -1.08372540e+00 7.28840508e-01 1.30601272e+00 2.54954010 0.94563329 697.25 -8.68135317e-01 7.86668937e-01 1.17154042e+00 2.40538500 0.93353001 697.50 -7.17982796e-01 7.45522521e-01 1.03503774e+00 2.33737907 0.90844433 697.75 -5.80861058e-01 6.51308885e-01 8.72698592e-01 2.29908287 0.87114800 698.00 -5.08931269e-01 5.58224002e-01 7.55397295e-01 2.31003652 0.83735478 698.25 -4.51386951e-01 4.17638755e-01 6.14957160e-01 2.39500951 0.83602102 698.50 -5.01292841e-01 2.49187827e-01 5.59811652e-01 2.68027548 0.78710684 698.75 -5.79457868e-01 1.49048278e-01 5.98319990e-01 2.88983012 0.80542012 699.00 -7.06963315e-01 1.61536465e-01 7.25183534e-01 2.91695562 0.81922365 699.25 -7.96310312e-01 1.43987485e-01 8.09223398e-01 2.96270720 0.87466555 699.50 -9.69492859e-01 1.77511669e-01 9.85609860e-01 2.96050110 0.88979286 699.75 -1.05596596e+00 2.28060579e-01 1.08031280e+00 2.92888627 0.91388568 700.00 -1.13033370e+00 4.80782238e-01 1.22833458e+00 2.73942949 0.89251532 700.25 -1.10380166e+00 6.46121526e-01 1.27900396e+00 2.61200729 0.92713861 700.50 -9.61073844e-01 7.49644594e-01 1.21886421e+00 2.47916183 0.94130486 700.75 -8.48180814e-01 8.28855371e-01 1.18592239e+00 2.36771755 0.94570835 701.00 -6.84184974e-01 8.72291150e-01 1.10860314e+00 2.23592389 0.96035231 701.25 -6.22907468e-01 8.64856224e-01 1.06582832e+00 2.19498003 0.96677567 701.50 -4.83491101e-01 8.19031817e-01 9.51092405e-01 2.10406799 0.96232857 701.75 -4.60969703e-01 7.82556133e-01 9.08232992e-01 2.10313020 0.97421718 702.00 -4.21727650e-01 7.50426297e-01 8.60809990e-01 2.08279380 0.97060045 702.25 -3.84891357e-01 7.42904688e-01 8.36689149e-01 2.04881084 0.97222875 702.50 -2.76606593e-01 7.25049573e-01 7.76020677e-01 1.93525363 0.96223227 702.75 -2.11785600e-01 6.91741840e-01 7.23436185e-01 1.86789741 0.95819014 703.00 -1.04046146e-01 6.07293034e-01 6.16141567e-01 1.74047665 0.95609540 703.25 -7.60473717e-02 5.56295873e-01 5.61469768e-01 1.70665729 0.94206497 703.50 -9.26386550e-02 4.56640567e-01 4.65942623e-01 1.77094994 0.91246321 703.75 -1.03317077e-01 4.08204347e-01 4.21076249e-01 1.81869178 0.90801383 704.00 -1.13174921e-01 3.36332562e-01 3.54863573e-01 1.89539153 0.88595662 704.25 -9.22140101e-02 3.29844502e-01 3.42492072e-01 1.84340451 0.82898810 704.50 -3.83379132e-02 2.83936269e-01 2.86512828e-01 1.70500760 0.80383096 704.75 -3.63936979e-02 2.56436537e-01 2.59006175e-01 1.71177572 0.73017230 705.00 -7.27346238e-02 1.59327295e-01 1.75144262e-01 1.99905139 0.51196855 705.25 -7.96117351e-02 9.32901340e-02 1.22642071e-01 2.27724815 0.30067191 705.50 -5.44277046e-02 -8.74107606e-03 5.51251434e-02 -2.98235266 0.09055071 705.75 -7.34222626e-02 -7.83603169e-02 1.07383276e-01 -2.32367223 0.23625561 706.00 -1.24960862e-01 -1.83170360e-01 2.21735423e-01 -2.16948343 0.55832812 706.25 -1.73763094e-01 -2.59507175e-01 3.12310081e-01 -2.16081921 0.71347863 706.50 -2.84607407e-01 -3.05665127e-01 4.17651225e-01 -2.32053504 0.81838648 706.75 -3.70768383e-01 -3.22073166e-01 4.91121490e-01 -2.42636244 0.78156961 707.00 -4.83780482e-01 -2.61954099e-01 5.50148621e-01 -2.64531960 0.74984911 707.25 -5.92444813e-01 -2.40430258e-01 6.39372790e-01 -2.75607289 0.76459392 707.50 -6.87838057e-01 -2.76515081e-01 7.41337833e-01 -2.75935809 0.84759534 707.75 -7.35946727e-01 -2.21753259e-01 7.68630010e-01 -2.84892804 0.84959560 708.00 -7.78728126e-01 -1.88893739e-01 8.01310388e-01 -2.90362190 0.78695524 708.25 -8.80972455e-01 -1.27132890e-01 8.90098443e-01 -2.99827236 0.76256572 708.50 -1.02436888e+00 -3.47260382e-02 1.02495732e+00 -3.10770570 0.83171473 708.75 -9.15606898e-01 2.77453924e-02 9.16027182e-01 3.11129919 0.74717177 709.00 -9.46349246e-01 1.61600968e-01 9.60047795e-01 2.97246150 0.80622678 709.25 -9.20216488e-01 3.82785180e-01 9.96655848e-01 2.74739276 0.82839328 709.50 -8.37751218e-01 4.16324913e-01 9.35496412e-01 2.68038376 0.83064916 709.75 -7.20790296e-01 4.99924613e-01 8.77190555e-01 2.53518947 0.76814680 710.00 -6.24059185e-01 5.44965269e-01 8.28514943e-01 2.42374959 0.78545760 710.25 -6.41607695e-01 4.64616503e-01 7.92167235e-01 2.51484563 0.78101186 710.50 -6.87094186e-01 4.86312912e-01 8.41783030e-01 2.52566293 0.79762625 710.75 -6.87178071e-01 5.79332982e-01 8.98799425e-01 2.44114090 0.83825680 711.00 -6.12953201e-01 6.30638552e-01 8.79441078e-01 2.34197426 0.85017367 711.25 -5.24528050e-01 7.96866608e-01 9.54005275e-01 2.15294112 0.88966752 711.50 -4.89098034e-01 9.09195305e-01 1.03240156e+00 2.06433800 0.90335624 711.75 -2.20327904e-01 9.76762608e-01 1.00130394e+00 1.79265281 0.90437270 712.00 -6.04443789e-02 9.21940631e-01 9.23919937e-01 1.63626475 0.89516254 712.25 1.05736727e-01 8.31507735e-01 8.38203656e-01 1.44431252 0.90328672 712.50 1.81936692e-01 7.69530310e-01 7.90745128e-01 1.33863377 0.88096232 712.75 2.72957537e-01 6.35370519e-01 6.91521159e-01 1.16503276 0.90479596 713.00 3.16563865e-01 5.64746310e-01 6.47418779e-01 1.05989571 0.88674088 713.25 4.55903539e-01 4.02154985e-01 6.07928177e-01 0.72284017 0.81960370 713.50 4.62159433e-01 3.11378111e-01 5.57268041e-01 0.59288774 0.79057576 713.75 4.50098920e-01 1.50408854e-01 4.74564918e-01 0.32250196 0.72208529 714.00 4.61839531e-01 9.74126872e-02 4.72001042e-01 0.20787627 0.75568451 714.25 4.56078149e-01 -1.36956010e-01 4.76197676e-01 -0.29172344 0.71610680 714.50 3.98557384e-01 -2.49256908e-01 4.70081901e-01 -0.55888532 0.73996729 714.75 2.84704478e-01 -3.24423135e-01 4.31632958e-01 -0.85051179 0.80166973 715.00 2.05946232e-01 -3.36590807e-01 3.94597544e-01 -1.02170232 0.74702892 715.25 5.90268020e-02 -3.74887699e-01 3.79506193e-01 -1.41462649 0.78967083 715.50 4.89561134e-02 -3.78204772e-01 3.81360133e-01 -1.44206871 0.74792056 715.75 -3.15504454e-03 -3.62182564e-01 3.62196306e-01 -1.57950731 0.63981294 716.00 -1.08253624e-02 -3.26064035e-01 3.26243687e-01 -1.60398425 0.58373901 716.25 -1.18459597e-02 -2.67357919e-01 2.67620222e-01 -1.61507486 0.47016129 716.50 -8.99645383e-03 -2.77296994e-01 2.77442893e-01 -1.60322834 0.45829970 716.75 7.79305610e-03 -3.15554767e-01 3.15650983e-01 -1.54610498 0.49572426 717.00 -8.79338563e-03 -4.78942889e-01 4.79023606e-01 -1.58915425 0.60926082 717.25 -1.00483804e-01 -6.27941805e-01 6.35930739e-01 -1.72947195 0.66254011 717.50 -2.76696728e-01 -6.64314415e-01 7.19635130e-01 -1.96545796 0.70281995 717.75 -2.96085597e-01 -5.05083008e-01 5.85470345e-01 -2.10101572 0.64608592 718.00 -2.82841028e-01 -4.06317525e-01 4.95068660e-01 -2.17890568 0.62937580 718.25 -3.08050782e-01 -3.82032640e-01 4.90758823e-01 -2.24939528 0.64252627 718.50 -2.85696797e-01 -4.33404413e-01 5.19097337e-01 -2.15360642 0.61316319 718.75 -3.52177244e-01 -4.25065486e-01 5.52004962e-01 -2.26268999 0.60791678 719.00 -3.85458796e-01 -2.69848012e-01 4.70527824e-01 -2.53081993 0.52769176 719.25 -3.46759720e-01 -2.97888909e-01 4.57143419e-01 -2.43185976 0.47435723 719.50 -3.56518467e-01 -3.23655059e-01 4.81516369e-01 -2.40447316 0.48671359 719.75 -3.78141702e-01 -2.90438724e-01 4.76807927e-01 -2.48662765 0.61729777 720.00 -4.40422986e-01 -1.38601759e-01 4.61717288e-01 -2.83670344 0.70155327 720.25 -3.64998246e-01 -4.13617748e-02 3.67334338e-01 -3.02875354 0.61012058 720.50 -2.75914373e-01 -4.04536705e-02 2.78864197e-01 -2.99601313 0.42237487 720.75 -1.86392031e-01 -5.21483675e-02 1.93549584e-01 -2.86878993 0.28875722 721.00 -1.69866539e-01 -6.08251437e-02 1.80428211e-01 -2.79774131 0.21979968 721.25 -1.35210363e-01 -6.31257088e-02 1.49220298e-01 -2.70479825 0.16097458 721.50 7.66378392e-03 2.25817751e-02 2.38468059e-02 1.24361443 0.00550110 721.75 4.35162245e-02 9.40953989e-02 1.03670661e-01 1.13762153 0.11912581 722.00 9.36369146e-02 1.62807385e-01 1.87814047e-01 1.04885742 0.20875899 722.25 1.33829866e-01 3.05951550e-01 3.33941288e-01 1.15845156 0.29663943 722.50 3.29356364e-01 6.49262185e-01 7.28022664e-01 1.10134336 0.41941933 722.75 3.41479138e-01 9.09163107e-01 9.71177408e-01 1.21150217 0.39039689 723.00 -3.71564647e-01 1.47940480e+00 1.52535204e+00 1.81686476 0.30128611 723.25 -1.13949436e+00 1.48073923e+00 1.86843144e+00 2.22668887 0.19519283 723.50 -3.64684670e+00 -6.62798050e-01 3.70658766e+00 -2.96180949 0.47764369 723.75 -3.90834752e+00 -1.25129612e+00 4.10376928e+00 -2.83174468 0.63706716 724.00 -3.31436172e+00 -1.78575624e+00 3.76482655e+00 -2.64739405 0.79358290 724.25 -3.07816407e+00 -1.79109283e+00 3.56133509e+00 -2.61461035 0.83663028 724.50 -2.76851126e+00 -1.77257376e+00 3.28735035e+00 -2.57209331 0.91282423 724.75 -2.73799698e+00 -1.72887942e+00 3.23815557e+00 -2.57837609 0.93627618 725.00 -2.62834799e+00 -1.75419397e+00 3.15996988e+00 -2.55307344 0.95592769 725.25 -2.53691560e+00 -1.64791338e+00 3.02515442e+00 -2.56551725 0.95727659 725.50 -2.64406526e+00 -1.56982203e+00 3.07496704e+00 -2.60580706 0.97386341 725.75 -2.62387112e+00 -1.55748280e+00 3.05130338e+00 -2.60590560 0.97225588 726.00 -2.68152900e+00 -1.50507673e+00 3.07503719e+00 -2.63013381 0.97429355 726.25 -2.72452338e+00 -1.48427582e+00 3.10259606e+00 -2.64276313 0.97255896 726.50 -2.73029170e+00 -1.39522290e+00 3.06612780e+00 -2.66917109 0.97536523 726.75 -2.79907357e+00 -1.26485339e+00 3.07159030e+00 -2.71717404 0.97542539 727.00 -2.84672873e+00 -1.04368526e+00 3.03201969e+00 -2.79018355 0.97532266 727.25 -2.80159330e+00 -9.33663088e-01 2.95307497e+00 -2.81990678 0.96849866 727.50 -2.77689519e+00 -7.32951874e-01 2.87199675e+00 -2.88353152 0.97814161 727.75 -2.84170761e+00 -7.18420931e-01 2.93111426e+00 -2.89396812 0.97168606 728.00 -3.08128776e+00 -6.83842611e-01 3.15625965e+00 -2.92319835 0.96461599 728.25 -3.10564772e+00 -5.84924315e-01 3.16025066e+00 -2.95543130 0.95081403 728.50 -3.13403759e+00 -3.92242337e-01 3.15848788e+00 -3.01708446 0.95909246 728.75 -3.07700101e+00 -1.19100825e-01 3.07930515e+00 -3.10290518 0.92909876 729.00 -2.96290175e+00 2.66793216e-01 2.97488914e+00 3.05179027 0.89562941 729.25 -2.68970783e+00 4.23441624e-01 2.72283511e+00 2.98544391 0.91777834 729.50 -2.51082886e+00 5.52041246e-01 2.57079970e+00 2.92517193 0.91780615 729.75 -2.26567678e+00 5.10817758e-01 2.32254732e+00 2.91984115 0.86154698 730.00 -2.07901990e+00 5.82289634e-01 2.15902408e+00 2.86851078 0.82625025 730.25 -1.89990716e+00 3.88399354e-01 1.93920119e+00 2.93994046 0.82744034 730.50 -1.81235581e+00 2.28377097e-01 1.82668817e+00 3.01624216 0.85773077 730.75 -1.79878988e+00 1.38099894e-01 1.80408332e+00 3.06496919 0.91854775 731.00 -1.79987738e+00 1.94447735e-01 1.81035038e+00 3.03397615 0.94448926 731.25 -1.82857240e+00 8.56514437e-02 1.83057728e+00 3.09478626 0.95486017 731.50 -1.82485851e+00 8.27269164e-02 1.82673270e+00 3.09629034 0.95050043 731.75 -1.78756677e+00 1.14952480e-01 1.79125906e+00 3.07737440 0.96209489 732.00 -1.78756945e+00 1.25470987e-01 1.79196750e+00 3.07151675 0.98164641 732.25 -1.84628132e+00 6.88115546e-02 1.84756319e+00 3.10433954 0.98946411 732.50 -1.86161377e+00 6.14438660e-02 1.86262750e+00 3.10859893 0.99034474 732.75 -1.94050433e+00 1.16917451e-01 1.94402334e+00 3.08141434 0.98728780 733.00 -2.00638495e+00 1.14783704e-01 2.00966561e+00 3.08444573 0.98956390 733.25 -2.04148961e+00 1.47348098e-01 2.04680026e+00 3.06954084 0.98946423 733.50 -2.05172513e+00 1.72929709e-01 2.05899992e+00 3.05750637 0.99033918 733.75 -2.09636185e+00 2.34214541e-01 2.10940500e+00 3.03032977 0.99038165 734.00 -2.12428400e+00 2.48577852e-01 2.13877850e+00 3.02510517 0.99064183 734.25 -2.12615382e+00 3.37649989e-01 2.15279762e+00 2.98409997 0.98895229 734.50 -2.09380415e+00 3.46698994e-01 2.12231383e+00 2.97749825 0.98743061 734.75 -2.08946194e+00 3.99063585e-01 2.12722893e+00 2.95287664 0.98784166 735.00 -2.08013446e+00 4.30052854e-01 2.12412449e+00 2.93772210 0.98510933 735.25 -2.02189171e+00 4.67458364e-01 2.07522611e+00 2.91438626 0.98383347 735.50 -1.97127992e+00 4.39501170e-01 2.01967963e+00 2.92222820 0.98210474 735.75 -1.94400299e+00 3.58282397e-01 1.97674326e+00 2.95933649 0.98220549 736.00 -1.92653173e+00 3.35368691e-01 1.95550420e+00 2.96924077 0.98116180 736.25 -1.89119574e+00 2.93574090e-01 1.91384615e+00 2.98758981 0.97602222 736.50 -1.80852570e+00 2.62351165e-01 1.82745543e+00 2.99753399 0.95224048 736.75 -1.73975483e+00 -3.25833114e-02 1.74005992e+00 -3.12286616 0.93967672 737.00 -1.74802840e+00 -1.01263050e-01 1.75095902e+00 -3.08372746 0.92010068 737.25 -1.70157459e+00 -1.84910234e-01 1.71159221e+00 -3.03334734 0.84486328 737.50 -1.79042841e+00 -2.23534769e-01 1.80432860e+00 -3.01738547 0.81548901 737.75 -1.68825660e+00 -4.32185459e-01 1.74269752e+00 -2.89097953 0.78007704 738.00 -1.70529536e+00 -4.83333998e-01 1.77246834e+00 -2.86540500 0.68460983 738.25 -1.61199479e+00 -7.62801179e-01 1.78336560e+00 -2.69961132 0.67448973 738.50 -1.37529223e+00 -7.91500067e-01 1.58678955e+00 -2.61937210 0.42538008 738.75 -1.48515011e+00 -5.55739027e-01 1.58572278e+00 -2.78352599 0.27720546 739.00 -1.17726610e+00 -2.15551715e-01 1.19683667e+00 -2.96050333 0.15288393 739.25 -1.09379705e+00 2.47045425e-01 1.12134894e+00 2.91945943 0.16703824 739.50 -9.23062961e-01 2.25639076e-01 9.50241139e-01 2.90184805 0.16940693 739.75 -9.05753596e-01 2.46020956e-01 9.38571194e-01 2.87637134 0.16533131 740.00 -7.31985959e-01 6.82905363e-01 1.00108100e+00 2.39086918 0.15520056 740.25 -1.26923610e-01 8.38241013e-01 8.47795729e-01 1.72107142 0.13384652 740.50 2.32894000e-01 8.40599824e-01 8.72265831e-01 1.30051882 0.13602416 740.75 3.57588526e-01 8.75759308e-01 9.45951331e-01 1.18313966 0.14010740 741.00 1.44330300e-01 9.76013023e-01 9.86626908e-01 1.42398288 0.15986992 741.25 1.21929768e-01 1.24815935e+00 1.25410072e+00 1.47341764 0.23412350 741.50 1.79488975e-01 1.93316183e+00 1.94147649e+00 1.47821440 0.43952965 741.75 3.30536305e-01 2.15249997e+00 2.17773056e+00 1.41842727 0.51381675 742.00 1.24510478e-01 2.41198162e+00 2.41519320e+00 1.51922045 0.49449084 742.25 2.08182393e-01 2.46532948e+00 2.47410375e+00 1.48655215 0.57136456 742.50 3.51203446e-01 2.26130035e+00 2.28841062e+00 1.41671693 0.44813441 742.75 4.62865166e-01 2.28167706e+00 2.32815257e+00 1.37065054 0.44587800 743.00 5.10001412e-01 1.92401234e+00 1.99045847e+00 1.31168351 0.45901819 743.25 9.67893979e-01 1.96422692e+00 2.18975025e+00 1.11295685 0.54462917 743.50 1.19285606e+00 2.68790674e+00 2.94070540e+00 1.15312175 0.69156450 743.75 1.09078311e+00 2.77762261e+00 2.98412385e+00 1.19659551 0.67375335 744.00 1.03824026e+00 2.55349524e+00 2.75649792e+00 1.18461694 0.65403076 744.25 1.19132203e+00 2.69991235e+00 2.95106335e+00 1.15524711 0.70130978 744.50 1.52192357e+00 2.96929800e+00 3.33661235e+00 1.09715656 0.74031080 744.75 1.65598490e+00 3.21433932e+00 3.61583507e+00 1.09507330 0.75114614 745.00 2.23843414e+00 3.23927144e+00 3.93744420e+00 0.96611582 0.71236670 745.25 2.89765065e+00 2.79847717e+00 4.02838104e+00 0.76798924 0.71692308 745.50 3.46659725e+00 1.71527819e+00 3.86774815e+00 0.45948032 0.78715048 745.75 3.42742688e+00 1.84626288e+00 3.89306327e+00 0.49410541 0.80713816 746.00 3.83706349e+00 2.33832939e+00 4.49342192e+00 0.54730696 0.85508680 746.25 3.96001547e+00 2.05463229e+00 4.46130433e+00 0.47860931 0.80947254 746.50 4.91993397e+00 9.00992032e-01 5.00175339e+00 0.18112394 0.81201952 746.75 5.03586967e+00 -1.26385790e-02 5.03588553e+00 -0.00250971 0.82444795 747.00 4.41376564e+00 -2.32308146e+00 4.98778854e+00 -0.48448625 0.80374631 747.25 3.35532336e+00 -3.33997025e+00 4.73429996e+00 -0.78310505 0.83893474 747.50 1.32435152e+00 -3.05072155e+00 3.32577945e+00 -1.16123403 0.84548132 747.75 8.94034567e-01 -2.38475559e+00 2.54683275e+00 -1.21211712 0.88817481 748.00 1.08641102e+00 -2.01492557e+00 2.28915136e+00 -1.07629683 0.93872618 748.25 1.10412450e+00 -1.96974056e+00 2.25808963e+00 -1.05989465 0.90919610 748.50 1.00090309e+00 -2.02837579e+00 2.26188314e+00 -1.11240201 0.89762896 748.75 8.40460360e-01 -1.97357844e+00 2.14508403e+00 -1.16820080 0.88363291 749.00 8.73697718e-01 -2.00398365e+00 2.18616060e+00 -1.15966201 0.85196210 749.25 6.50778859e-01 -2.54130041e+00 2.62330343e+00 -1.32010257 0.84375526 749.50 2.34173047e-01 -2.83160403e+00 2.84127056e+00 -1.48828431 0.90715272 749.75 -1.16394849e-01 -2.78212914e+00 2.78456286e+00 -1.61260855 0.88936754 750.00 -7.20621037e-01 -2.64577322e+00 2.74215437e+00 -1.83671292 0.89820939 750.25 -1.09289722e+00 -2.40669094e+00 2.64321501e+00 -1.99706108 0.88172636 750.50 -1.26638201e+00 -2.15048136e+00 2.49565492e+00 -2.10300149 0.90616394 750.75 -1.13773285e+00 -1.97040904e+00 2.27529071e+00 -2.09443951 0.77941934 751.00 -1.09714357e+00 -1.70815394e+00 2.03015119e+00 -2.14173795 0.65245700 751.25 -1.25182511e+00 -1.67098490e+00 2.08788329e+00 -2.21375581 0.43158673 751.50 -1.53220040e+00 -1.19635607e+00 1.94394082e+00 -2.47866349 0.26439800 751.75 -2.45607529e+00 -9.47274584e-01 2.63241999e+00 -2.77348625 0.45447399 752.00 -3.01627707e+00 -4.53287086e-01 3.05014697e+00 -2.99242856 0.54676852 752.25 -2.50064767e+00 5.39628553e-01 2.55820987e+00 2.92905625 0.39848498 752.50 -2.05658388e+00 1.28755681e+00 2.42638410e+00 2.58222730 0.41405803 752.75 -1.22648563e+00 1.53382044e+00 1.96389209e+00 2.24531034 0.34759714 753.00 -8.77529145e-01 1.14849543e+00 1.44537163e+00 2.22324063 0.31560096 753.25 -1.28063327e+00 7.13560055e-01 1.46601143e+00 2.63324367 0.45331359 753.50 -1.47035550e+00 7.90806543e-01 1.66952697e+00 2.64813824 0.63490516 753.75 -1.52209783e+00 8.33456282e-01 1.73534757e+00 2.64061641 0.71416444 754.00 -1.61608555e+00 9.24634892e-01 1.86190284e+00 2.62190680 0.70577859 754.25 -1.77965719e+00 1.15514826e+00 2.12168500e+00 2.56586114 0.63107761 754.50 -1.85550474e+00 1.10719827e+00 2.16073734e+00 2.60359577 0.59465820 754.75 -1.87083267e+00 8.15866343e-01 2.04099309e+00 2.73035960 0.55580859 755.00 -1.84785783e+00 8.77342041e-01 2.04555802e+00 2.69831672 0.47985057 755.25 -1.79932263e+00 1.45719839e+00 2.31538098e+00 2.46086871 0.41437391 755.50 -1.67380709e+00 1.08171356e+00 1.99292107e+00 2.56785153 0.31376001 755.75 -1.50826380e+00 7.31784150e-01 1.67641515e+00 2.68986865 0.21270158 756.00 -1.70765171e+00 7.51534289e-01 1.86571116e+00 2.72700359 0.24262977 756.25 -1.65825909e+00 7.55325524e-01 1.82217997e+00 2.71418009 0.20593487 756.50 -1.47965142e+00 1.55613445e-02 1.47973325e+00 3.13107614 0.16608108 756.75 -1.32114042e+00 -4.03559519e-03 1.32114659e+00 -3.13853803 0.11795129 757.00 -1.19207988e+00 3.66275656e-01 1.24708151e+00 2.84349084 0.10267375 757.25 -2.25030636e-01 6.46799179e-01 6.84826960e-01 1.90561179 0.03668022 757.50 -7.92069116e-02 6.08135750e-01 6.13272228e-01 1.70031269 0.03571119 757.75 3.05245234e-01 3.65469851e-01 4.76175246e-01 0.87494966 0.02161524 758.00 2.68105567e-01 5.51376341e-01 6.13103959e-01 1.11821083 0.03186683 758.25 2.37718512e-01 -3.01909177e-01 3.84264548e-01 -0.90379543 0.01672326 758.50 4.83778636e-01 -7.68522243e-01 9.08112441e-01 -1.00897330 0.12023733 758.75 6.10989985e-01 -6.93921750e-01 9.24573500e-01 -0.84886635 0.17849509 759.00 2.40099850e-01 -7.82739118e-01 8.18735895e-01 -1.27316471 0.16456739 759.25 -8.92538318e-02 -7.41619779e-01 7.46971313e-01 -1.69057013 0.18415570 759.50 -2.66625358e-02 -3.13875231e-01 3.15005638e-01 -1.65553917 0.06566265 759.75 1.52178076e-02 -3.93619062e-01 3.93913122e-01 -1.53215432 0.14449638 760.00 -8.02643449e-02 -2.70212238e-01 2.81881214e-01 -1.85953702 0.08277357 760.25 -1.00581214e-01 -6.13053267e-02 1.17791866e-01 -2.59420932 0.01297397 760.50 -7.49529940e-02 5.17147904e-02 9.10624558e-02 2.53763476 0.00696750 760.75 -1.71148782e-02 -1.00069741e-01 1.01522766e-01 -1.74018690 0.01117469 761.00 -2.77372141e-01 -7.25195997e-02 2.86695652e-01 -2.88586468 0.08948629 761.25 -2.16219794e-01 1.80759039e-01 2.81824111e-01 2.44528460 0.07816344 761.50 -2.17019066e-01 4.02799055e-01 4.57541641e-01 2.06498260 0.19493621 761.75 -2.01846302e-01 5.78302920e-01 6.12516283e-01 1.90660864 0.38622185 762.00 -1.74758682e-01 8.44410800e-01 8.62305164e-01 1.77487449 0.54018977 762.25 -1.69274908e-01 1.15960982e+00 1.17189971e+00 1.71574827 0.68169359 762.50 -5.28212464e-02 1.64289425e+00 1.64374316e+00 1.60293659 0.75408319 762.75 5.58947437e-02 1.83599992e+00 1.83685054e+00 1.54036197 0.76121263 763.00 7.10807266e-01 1.70215919e+00 1.84461185e+00 1.17521741 0.61582442 763.25 1.15210761e+00 1.79102932e+00 2.12958634e+00 0.99916986 0.58325752 763.50 1.90482172e+00 1.24690818e+00 2.27664793e+00 0.57960654 0.60181922 763.75 2.29735498e+00 9.16892045e-01 2.47356644e+00 0.37973691 0.73873036 764.00 2.38426968e+00 6.81658583e-01 2.47979844e+00 0.27846975 0.77578173 764.25 2.26290937e+00 5.12836488e-01 2.32029310e+00 0.22286256 0.76178316 764.50 2.16705980e+00 3.82587098e-01 2.20057290e+00 0.17474594 0.86063109 764.75 2.30336873e+00 4.85593703e-01 2.35399846e+00 0.20777639 0.91048961 765.00 2.41941371e+00 3.49518652e-01 2.44452981e+00 0.14347161 0.94650748 765.25 2.45440591e+00 3.60116525e-01 2.48068383e+00 0.14568302 0.95764841 765.50 2.71802549e+00 5.15011900e-01 2.76638751e+00 0.18726017 0.95462763 765.75 2.87083899e+00 7.03534771e-01 2.95578716e+00 0.24032616 0.95288082 766.00 3.26404021e+00 6.36555793e-01 3.32553181e+00 0.19260333 0.95901095 766.25 3.48382700e+00 5.44345036e-01 3.52609729e+00 0.15499592 0.95099421 766.50 4.18152399e+00 3.04632478e-01 4.19260585e+00 0.07272355 0.94396998 766.75 4.39607647e+00 8.29263392e-02 4.39685855e+00 0.01886148 0.94236029 767.00 4.96677466e+00 -6.00947299e-01 5.00299792e+00 -0.12040818 0.92122528 767.25 4.91022915e+00 -1.36430030e+00 5.09624034e+00 -0.27101260 0.92318597 767.50 4.45607542e+00 -2.49590359e+00 5.10745954e+00 -0.51057397 0.93759625 767.75 3.98476072e+00 -2.83295543e+00 4.88916706e+00 -0.61803551 0.92074244 768.00 3.02163432e+00 -3.07088632e+00 4.30820343e+00 -0.79348200 0.90538656 768.25 2.41648162e+00 -2.96259723e+00 3.82313560e+00 -0.88657734 0.89173542 768.50 1.93074623e+00 -2.71009398e+00 3.32752015e+00 -0.95177818 0.90297345 768.75 1.80002717e+00 -2.38447058e+00 2.98760736e+00 -0.92416917 0.91515753 769.00 1.64550437e+00 -1.95486710e+00 2.55522798e+00 -0.87111285 0.90836358 769.25 1.65112579e+00 -1.68368096e+00 2.35817682e+00 -0.79516009 0.90009332 769.50 1.77550944e+00 -1.57277817e+00 2.37193274e+00 -0.72492424 0.91032419 769.75 1.86177700e+00 -1.52499268e+00 2.40661926e+00 -0.68628284 0.88868784 770.00 1.93745092e+00 -1.54265887e+00 2.47659291e+00 -0.67243866 0.88225332 770.25 1.92672386e+00 -1.57767720e+00 2.49024701e+00 -0.68612322 0.86311209 770.50 2.01990141e+00 -1.70570081e+00 2.64375055e+00 -0.70126174 0.87175237 770.75 2.08404885e+00 -1.82620835e+00 2.77097394e+00 -0.71955396 0.82208520 771.00 2.06137501e+00 -1.94392425e+00 2.83339168e+00 -0.75608272 0.78824399 771.25 2.10461605e+00 -2.04271300e+00 2.93293115e+00 -0.77047327 0.76109641 771.50 2.12410352e+00 -2.11881535e+00 3.00019903e+00 -0.78415181 0.74477509 771.75 2.13602314e+00 -2.09019706e+00 2.98856464e+00 -0.77455531 0.72645727 772.00 2.11871634e+00 -2.26615002e+00 3.10232089e+00 -0.81900880 0.65065707 772.25 1.14467045e+00 -2.42926620e+00 2.68544311e+00 -1.13045294 0.44892446 772.50 6.92918950e-01 -3.14415462e+00 3.21960323e+00 -1.35388051 0.51591986 772.75 -2.00627787e-01 -3.15475695e+00 3.16113001e+00 -1.63430612 0.48692915 773.00 -8.87183372e-01 -3.19811175e+00 3.31888733e+00 -1.84140032 0.55484949 773.25 -1.75735993e+00 -1.89446651e+00 2.58405056e+00 -2.31866746 0.53387189 773.50 -1.95249451e+00 -1.34176571e+00 2.36908632e+00 -2.53950506 0.58383721 773.75 -1.38017811e+00 -1.19006035e+00 1.82239821e+00 -2.43002895 0.52716656 774.00 -1.16806804e+00 -9.52864085e-01 1.50742592e+00 -2.45731509 0.44652504 774.25 -6.55587403e-01 -8.09383152e-01 1.04158338e+00 -2.25159549 0.27903702 774.50 -8.08115320e-01 -8.18549397e-01 1.15024931e+00 -2.34978018 0.33540960 774.75 -1.20145495e+00 -7.14034256e-01 1.39761902e+00 -2.60536898 0.48869645 775.00 -1.21242620e+00 -5.39331542e-01 1.32697242e+00 -2.72304091 0.46723566 775.25 -1.39392437e+00 -1.86457920e-01 1.40633983e+00 -3.00861728 0.36398654 775.50 -1.59464761e+00 1.17813626e-01 1.59899377e+00 3.06784597 0.46136123 775.75 -1.20466271e+00 3.48546003e-01 1.25407199e+00 2.85995265 0.43324044 776.00 -8.91792299e-01 3.89065622e-01 9.72967401e-01 2.73021187 0.34308334 776.25 -6.77193735e-01 6.98634607e-01 9.72975678e-01 2.34061178 0.53204415 776.50 -7.83620132e-01 7.71022910e-01 1.09933473e+00 2.36429728 0.59391562 776.75 -8.43973737e-01 1.13713960e+00 1.41611374e+00 2.20928033 0.60880054 777.00 -7.16318856e-01 1.51770792e+00 1.67825803e+00 2.01177292 0.69726455 777.25 -4.54145697e-01 1.90056402e+00 1.95407060e+00 1.80535121 0.75238504 777.50 -1.87893813e-01 2.00075696e+00 2.00956027e+00 1.66443306 0.73071184 777.75 5.31040706e-01 2.06288810e+00 2.13014355e+00 1.31884094 0.78361356 778.00 9.27249673e-01 1.90593632e+00 2.11952476e+00 1.11800198 0.77350968 778.25 1.56400859e+00 1.78877519e+00 2.37609755e+00 0.85233680 0.83148132 778.50 1.67813065e+00 1.61807726e+00 2.33115776e+00 0.76718124 0.76063050 778.75 2.14639232e+00 1.02166445e+00 2.37714077e+00 0.44425698 0.72258240 779.00 2.38877900e+00 7.06673847e-01 2.49111481e+00 0.28762725 0.72995533 779.25 2.69798899e+00 -1.16429615e-01 2.70050004e+00 -0.04312746 0.78339928 779.50 2.37233157e+00 -4.49229394e-01 2.41449045e+00 -0.18714608 0.73840527 779.75 2.49211151e+00 -1.12977757e+00 2.73624143e+00 -0.42562924 0.74425002 780.00 2.17237365e+00 -2.02153122e+00 2.96745611e+00 -0.74944660 0.64749450 780.25 6.02901327e-01 -2.94521173e+00 3.00628711e+00 -1.36888028 0.66455049 780.50 -3.49883422e-01 -2.77347626e+00 2.79545863e+00 -1.69628680 0.71666892 780.75 -1.00220126e+00 -2.62455979e+00 2.80939877e+00 -1.93556327 0.77407534 781.00 -1.34489898e+00 -1.79801289e+00 2.24535156e+00 -2.21301098 0.64448884 781.25 -1.94717164e+00 -8.54093402e-01 2.12625326e+00 -2.72823178 0.72581961 781.50 -1.98167199e+00 -3.51335859e-01 2.01257565e+00 -2.96612334 0.72027802 781.75 -2.00589608e+00 1.23316747e-01 2.00968309e+00 3.08019279 0.80635974 782.00 -1.71483513e+00 4.63951976e-01 1.77648838e+00 2.87736645 0.70634400 782.25 -1.52107918e+00 9.53365521e-01 1.79515673e+00 2.58172214 0.72847328 782.50 -1.14071723e+00 1.27092248e+00 1.70777041e+00 2.30225652 0.67348795 782.75 -7.39638771e-01 1.49091665e+00 1.66430104e+00 2.03131639 0.70253978 783.00 -4.65547322e-01 1.52580789e+00 1.59525046e+00 1.86693942 0.77123543 783.25 -2.27717787e-01 1.39847765e+00 1.41689630e+00 1.73221228 0.78436012 783.50 1.27591128e-01 1.09944147e+00 1.10682024e+00 1.45526228 0.69150083 783.75 2.62617453e-01 1.10624335e+00 1.13698825e+00 1.33771523 0.76570116 784.00 4.19891705e-01 7.88099457e-01 8.92978051e-01 1.08126191 0.66521694 784.25 3.73480061e-01 6.05757238e-01 7.11638383e-01 1.01829598 0.59610176 784.50 1.07089925e-01 3.73203312e-01 3.88264039e-01 1.29135648 0.27052625 784.75 1.70921115e-02 2.70391586e-01 2.70931264e-01 1.50766788 0.18411434 785.00 -1.65059522e-01 1.28126467e-01 2.08952237e-01 2.48150584 0.09563536 785.25 -3.63746718e-01 1.13962791e-01 3.81181312e-01 2.83797676 0.25414220 785.50 -7.55936264e-01 2.31682246e-01 7.90642965e-01 2.84419805 0.61744798 785.75 -9.72294380e-01 3.36691601e-01 1.02894003e+00 2.80823065 0.73193759 786.00 -1.01394403e+00 7.91839480e-01 1.28650389e+00 2.47857605 0.79802179 786.25 -9.29599742e-01 9.86728844e-01 1.35565095e+00 2.32639157 0.87162477 786.50 -9.61944751e-01 1.35398166e+00 1.66090458e+00 2.18850550 0.90968016 786.75 -9.48160096e-01 1.49272733e+00 1.76840110e+00 2.13668718 0.89754984 787.00 -5.04837392e-01 1.76264973e+00 1.83351981e+00 1.84973744 0.81467410 787.25 -3.73609306e-01 1.76758598e+00 1.80663890e+00 1.77909740 0.84128951 787.50 -6.16315358e-02 1.62683624e+00 1.62800326e+00 1.60866251 0.87929970 787.75 -2.88009167e-02 1.67854821e+00 1.67879528e+00 1.58795287 0.88239302 788.00 6.23507590e-02 1.92083476e+00 1.92184645e+00 1.53834748 0.90498324 788.25 9.17635887e-02 2.00703792e+00 2.00913458e+00 1.52510724 0.88736767 788.50 1.26877254e-01 2.17265498e+00 2.17635648e+00 1.51246524 0.89358821 788.75 2.93863445e-01 2.29540383e+00 2.31413796e+00 1.44346640 0.90873695 789.00 5.81520549e-01 2.38440121e+00 2.45428916e+00 1.33158085 0.92126780 789.25 9.76518230e-01 2.33629088e+00 2.53216171e+00 1.17488836 0.91605001 789.50 1.45923160e+00 2.32735965e+00 2.74699104e+00 1.01076716 0.96013994 789.75 1.70786508e+00 2.18885711e+00 2.77631024e+00 0.90821197 0.95613983 790.00 1.98209575e+00 1.84549538e+00 2.70823868e+00 0.74972496 0.95186422 790.25 2.07323223e+00 1.50721543e+00 2.56319922e+00 0.62861019 0.95343582 790.50 2.05049732e+00 1.22007594e+00 2.38602694e+00 0.53674574 0.95076999 790.75 1.99942399e+00 1.11390184e+00 2.28877120e+00 0.50828660 0.95980352 791.00 1.99550214e+00 9.57184324e-01 2.21319467e+00 0.44725247 0.96323093 791.25 2.02643942e+00 7.91409271e-01 2.17549658e+00 0.37232625 0.95701964 791.50 2.11416258e+00 6.88918033e-01 2.22357628e+00 0.31500827 0.96510410 791.75 1.99319714e+00 4.32000634e-01 2.03947527e+00 0.21343633 0.94662195 792.00 1.94431299e+00 1.61856482e-01 1.95103832e+00 0.08305460 0.94633731 792.25 1.74597316e+00 2.22631048e-02 1.74611510e+00 0.01275042 0.93512063 792.50 1.53918053e+00 -8.61462365e-02 1.54158940e+00 -0.05591057 0.95308344 792.75 1.28346839e+00 -7.34187673e-02 1.28556658e+00 -0.05714114 0.90678725 793.00 1.05002969e+00 -7.01884285e-02 1.05237292e+00 -0.06674494 0.90804216 793.25 1.11370325e+00 3.22240721e-02 1.11416934e+00 0.02892609 0.86281036 793.50 1.29163131e+00 8.73880255e-02 1.29458414e+00 0.06755415 0.91025980 793.75 1.27188772e+00 -2.05975515e-02 1.27205450e+00 -0.01619306 0.93405379 794.00 1.36877309e+00 -7.77309309e-02 1.37097843e+00 -0.05672783 0.94610647 794.25 1.36189538e+00 -2.53473997e-01 1.38528267e+00 -0.18401309 0.95510809 794.50 1.27225725e+00 -3.84577353e-01 1.32911183e+00 -0.29354681 0.96395213 794.75 1.07347754e+00 -5.36608381e-01 1.20012607e+00 -0.46355043 0.94371806 795.00 9.11963919e-01 -6.13706265e-01 1.09923317e+00 -0.59234011 0.94233108 795.25 6.31329186e-01 -5.61838444e-01 8.45126605e-01 -0.72722333 0.89666530 795.50 4.98854369e-01 -4.71525760e-01 6.86434428e-01 -0.75724282 0.86102445 795.75 4.09853429e-01 -3.03969678e-01 5.10271887e-01 -0.63813862 0.81050986 796.00 3.93770456e-01 -2.37849050e-01 4.60029720e-01 -0.54337725 0.81883925 796.25 3.77798305e-01 -2.52977040e-02 3.78644336e-01 -0.06686106 0.67303201 796.50 4.06597373e-01 4.31846322e-02 4.08884258e-01 0.10581313 0.69470934 796.75 5.34332679e-01 2.10841484e-01 5.74426273e-01 0.37583253 0.81127383 797.00 6.42780944e-01 2.58143833e-01 6.92679998e-01 0.38188895 0.82672786 797.25 9.86099861e-01 1.41418078e-01 9.96188741e-01 0.14244030 0.87778979 797.50 1.10460194e+00 -2.93615555e-02 1.10499210e+00 -0.02657486 0.89745062 797.75 1.18150333e+00 -4.21822342e-01 1.25454542e+00 -0.34291650 0.91448967 798.00 1.10538621e+00 -5.85982679e-01 1.25110126e+00 -0.48744897 0.90580890 798.25 8.19976823e-01 -9.02825604e-01 1.21961308e+00 -0.83345069 0.88074541 798.50 6.98845225e-01 -9.86554646e-01 1.20899740e+00 -0.95447530 0.88968937 798.75 5.48390815e-01 -1.11605657e+00 1.24350905e+00 -1.11408078 0.89005685 799.00 4.49825939e-01 -1.18654767e+00 1.26895183e+00 -1.20843178 0.83861777 799.25 1.89736562e-01 -1.37911036e+00 1.39210105e+00 -1.43407568 0.83398624 799.50 1.87188059e-02 -1.38058680e+00 1.38071370e+00 -1.55723857 0.75525120 799.75 -4.48464305e-01 -1.39992777e+00 1.47000612e+00 -1.88081507 0.75238011 800.00 -6.91409441e-01 -1.35387053e+00 1.52020144e+00 -2.04296008 0.62021488 800.25 -1.05428958e+00 -1.52654167e+00 1.85522398e+00 -2.17521224 0.50347724 800.50 -1.26625733e+00 -8.84163256e-01 1.54439382e+00 -2.53204264 0.24518019 800.75 -1.60275339e+00 8.14111528e-01 1.79766404e+00 2.67160879 0.21610708 801.00 -9.64248087e-01 1.72291026e+00 1.97438449e+00 2.08102761 0.30686357 801.25 3.28135223e-01 2.01148682e+00 2.03807555e+00 1.40909002 0.47246942 801.50 9.65598584e-01 1.44320038e+00 1.73643542e+00 0.98113340 0.61932395 801.75 1.07912454e+00 1.19960474e+00 1.61355548e+00 0.83822064 0.76252939 802.00 9.82076433e-01 9.85248912e-01 1.39111090e+00 0.78701075 0.82143443 802.25 8.82147385e-01 6.93936346e-01 1.12237768e+00 0.66654410 0.84878307 802.50 7.03985209e-01 4.45547006e-01 8.33131028e-01 0.56425475 0.84554348 802.75 6.15607798e-01 3.65555012e-01 7.15963287e-01 0.53585673 0.88759012 803.00 4.53530948e-01 2.51423985e-01 5.18559872e-01 0.50619216 0.80178371 803.25 3.31420666e-01 1.90794227e-01 3.82416128e-01 0.52234965 0.82725303 803.50 2.12893127e-01 1.76003406e-01 2.76225782e-01 0.69082373 0.78147578 803.75 1.47017851e-01 1.58475056e-01 2.16167972e-01 0.82288459 0.72728134 804.00 4.06218867e-02 1.36175308e-01 1.42105075e-01 1.28089455 0.47272478 804.25 -3.53129017e-02 1.25610867e-01 1.30480232e-01 1.84485197 0.46140817 804.50 -2.04251617e-01 1.72185328e-01 2.67145111e-01 2.44117304 0.76998204 804.75 -2.76256800e-01 1.91924221e-01 3.36381816e-01 2.53441155 0.88165959 805.00 -4.07440572e-01 2.68202806e-01 4.87791518e-01 2.55943098 0.93288632 805.25 -4.44158254e-01 3.31258283e-01 5.54083572e-01 2.50077765 0.96459066 805.50 -4.99788993e-01 4.70447357e-01 6.86374354e-01 2.38642702 0.96915370 805.75 -5.07154454e-01 5.32961196e-01 7.35699175e-01 2.33138816 0.98472115 806.00 -5.07615436e-01 6.28783194e-01 8.08109978e-01 2.24997147 0.98876083 806.25 -5.06833736e-01 6.69938477e-01 8.40058330e-01 2.21846847 0.99167044 806.50 -4.91667716e-01 7.39147381e-01 8.87736444e-01 2.15777055 0.99094813 806.75 -4.79812182e-01 7.82116377e-01 9.17565124e-01 2.12106814 0.99081257 807.00 -4.68939231e-01 8.45364688e-01 9.66718914e-01 2.07725479 0.99218787 807.25 -4.66551027e-01 8.73128376e-01 9.89961121e-01 2.06154028 0.99250867 807.50 -4.56123704e-01 9.84352521e-01 1.08489572e+00 2.00471653 0.98816068 807.75 -4.25326579e-01 1.04006373e+00 1.12367044e+00 1.95898817 0.99056395 808.00 -3.44281509e-01 1.09978198e+00 1.15241058e+00 1.87417785 0.99318158 808.25 -3.08424682e-01 1.11241671e+00 1.15438153e+00 1.84125911 0.99443770 808.50 -2.71614380e-01 1.12479518e+00 1.15712514e+00 1.80773926 0.99524198 808.75 -2.57720651e-01 1.14308552e+00 1.17177832e+00 1.79254905 0.99479506 809.00 -2.21799828e-01 1.19516958e+00 1.21557619e+00 1.75428905 0.99567503 809.25 -1.88190399e-01 1.23215181e+00 1.24644042e+00 1.72235818 0.99389123 809.50 -9.48160337e-02 1.29380194e+00 1.29727158e+00 1.64395037 0.99447150 809.75 -5.06196418e-02 1.29586651e+00 1.29685479e+00 1.60983887 0.99240946 810.00 7.72507333e-02 1.30089257e+00 1.30318423e+00 1.51148311 0.99130318 810.25 1.48869665e-01 1.28391681e+00 1.29251869e+00 1.45536218 0.98893924 810.50 2.58238547e-01 1.20736284e+00 1.23467088e+00 1.36008476 0.98776960 810.75 2.92716485e-01 1.09115717e+00 1.12973754e+00 1.30870470 0.97097841 811.00 2.93844480e-01 9.17290103e-01 9.63205955e-01 1.26078522 0.97126079 811.25 2.20145789e-01 8.20859380e-01 8.49867219e-01 1.30877283 0.95618851 811.50 5.75080191e-02 7.47143304e-01 7.49353247e-01 1.49397726 0.96212836 811.75 -2.72216539e-02 7.45015924e-01 7.45513075e-01 1.60731843 0.94033870 812.00 -1.93215409e-01 7.92738154e-01 8.15944836e-01 1.80986676 0.92704913 812.25 -2.98677652e-01 8.46830928e-01 8.97959331e-01 1.90987487 0.90321202 812.50 -4.47548174e-01 9.57573467e-01 1.05699873e+00 2.00800694 0.93348514 812.75 -5.35184543e-01 1.07535513e+00 1.20117074e+00 2.03258756 0.89678111 813.00 -6.26482763e-01 1.19248579e+00 1.34703490e+00 2.05452447 0.85266019 813.25 -6.78325192e-01 1.50904239e+00 1.65448904e+00 1.99324024 0.72201831 813.50 -5.53235487e-01 2.26244450e+00 2.32910383e+00 1.81062014 0.71719981 813.75 9.36960484e-01 1.91114570e+00 2.12846725e+00 1.11497011 0.63113514 814.00 1.47340261e+00 1.31475747e+00 1.97471579e+00 0.72855987 0.84622729 814.25 1.19035974e+00 9.58066183e-01 1.52802066e+00 0.67769389 0.92905967 814.50 9.42717757e-01 8.73470507e-01 1.28517217e+00 0.74728883 0.92646675 814.75 5.77700232e-01 8.66903009e-01 1.04175735e+00 0.98298150 0.92001631 815.00 4.68780341e-01 9.11659626e-01 1.02512354e+00 1.09584905 0.95734425 815.25 3.58800562e-01 9.47736262e-01 1.01338140e+00 1.20888466 0.95927416 815.50 2.91950939e-01 9.67823101e-01 1.01089906e+00 1.27781973 0.96537348 815.75 2.30534261e-01 1.07363447e+00 1.09810611e+00 1.35928472 0.95357433 816.00 2.03984144e-01 1.17488984e+00 1.19246621e+00 1.39889016 0.96386692 816.25 1.59612187e-01 1.31896758e+00 1.32859006e+00 1.45036893 0.96349195 816.50 1.84665744e-01 1.42377309e+00 1.43569887e+00 1.44181471 0.97219199 816.75 3.08338192e-01 1.48496276e+00 1.51663669e+00 1.36606518 0.97534194 817.00 3.96964067e-01 1.53289516e+00 1.58346078e+00 1.31739928 0.97139503 817.25 4.93224243e-01 1.55590458e+00 1.63220992e+00 1.26381563 0.96674199 817.50 5.53140752e-01 1.53723048e+00 1.63372037e+00 1.22539176 0.96785285 817.75 6.45311716e-01 1.43342392e+00 1.57198325e+00 1.14778522 0.96647964 818.00 6.83309298e-01 1.39314682e+00 1.55169896e+00 1.11479447 0.96464522 818.25 6.66562299e-01 1.34896088e+00 1.50465968e+00 1.11185558 0.96435728 818.50 6.31052409e-01 1.29586429e+00 1.44135054e+00 1.11762359 0.96031200 818.75 5.38969670e-01 1.27759480e+00 1.38662785e+00 1.17158595 0.95462171 819.00 4.58313208e-01 1.26405190e+00 1.34457361e+00 1.22296334 0.95232889 819.25 2.06992386e-01 1.23569925e+00 1.25291600e+00 1.40482690 0.93722683 819.50 8.20089989e-02 1.26276928e+00 1.26542946e+00 1.50594363 0.90792261 819.75 -2.83997005e-01 1.41126458e+00 1.43955619e+00 1.76937991 0.81870037 820.00 -5.52932822e-01 1.45691959e+00 1.55831621e+00 1.93352545 0.73154069 820.25 -1.21984730e+00 1.12543266e+00 1.65970663e+00 2.39643006 0.49740510 820.50 -8.99414887e-01 6.43929988e-01 1.10616137e+00 2.52024649 0.21293538 820.75 -6.46201988e-01 -3.93415925e-01 7.56540217e-01 -2.59471847 0.11318327 821.00 -2.70938534e-01 -1.74575452e-01 3.22310840e-01 -2.56920947 0.03122440 821.25 2.99993983e-01 -1.72701430e-01 3.46153397e-01 -0.52234741 0.04025226 821.50 3.57745371e-01 -1.29861507e-01 3.80586076e-01 -0.34820869 0.07571784 821.75 4.56652221e-01 -1.14641175e-01 4.70822525e-01 -0.24596384 0.13863136 822.00 4.07152902e-01 6.77892175e-03 4.07209331e-01 0.01664803 0.09574658 822.25 3.97477046e-01 -7.91882233e-02 4.05288511e-01 -0.19665233 0.10179555 822.50 3.80905932e-01 -1.06164931e-01 3.95424230e-01 -0.27181851 0.16647255 822.75 3.22778905e-01 -1.48314359e-01 3.55222987e-01 -0.43071947 0.25248902 823.00 4.32397416e-01 -3.37745230e-02 4.33714472e-01 -0.07795163 0.43753754 823.25 4.52161665e-01 1.34721966e-02 4.52362323e-01 0.02978628 0.64532150 823.50 4.98932134e-01 1.00127479e-02 4.99032593e-01 0.02006566 0.76445270 823.75 5.23085548e-01 -1.10385844e-03 5.23086712e-01 -0.00211028 0.84577748 824.00 4.50431161e-01 7.17973390e-02 4.56117407e-01 0.15806718 0.78408245 824.25 4.01782805e-01 1.33116800e-01 4.23260564e-01 0.31993325 0.82000573 824.50 3.58349198e-01 1.99357775e-01 4.10070324e-01 0.50768449 0.81578045 824.75 3.18677992e-01 2.26704359e-01 3.91088901e-01 0.61832947 0.84832085 825.00 2.89853242e-01 3.49616184e-01 4.54143565e-01 0.87858456 0.82239101 825.25 2.74614124e-01 4.61955688e-01 5.37416017e-01 1.03446040 0.89463348 825.50 2.99548941e-01 6.38963600e-01 7.05694020e-01 1.13241518 0.91285051 825.75 3.37622765e-01 7.79370216e-01 8.49356854e-01 1.16200120 0.91359393 826.00 5.33503604e-01 1.11350987e+00 1.23471873e+00 1.12399272 0.89885383 826.25 7.29439095e-01 1.26791147e+00 1.46276481e+00 1.04873091 0.90709538 826.50 1.25688744e+00 1.10672105e+00 1.67469326e+00 0.72195076 0.80044886 826.75 1.47456188e+00 5.91194519e-01 1.58866098e+00 0.38130692 0.77350066 827.00 1.35858334e+00 4.08153440e-02 1.35919630e+00 0.03003354 0.88523032 827.25 1.27511342e+00 -3.91553724e-02 1.27571446e+00 -0.03069772 0.92702483 827.50 1.06249519e+00 -3.31459423e-02 1.06301208e+00 -0.03118621 0.96481036 827.75 9.88006684e-01 -2.93220799e-03 9.88011035e-01 -0.00296779 0.97180084 828.00 8.55728162e-01 4.33385337e-02 8.56824904e-01 0.05060198 0.98304781 828.25 8.15390777e-01 6.23990264e-02 8.17774882e-01 0.07637766 0.98144993 828.50 7.68000275e-01 1.36403225e-01 7.80019399e-01 0.17577534 0.97076246 828.75 7.43514586e-01 2.13070749e-01 7.73442360e-01 0.27909282 0.97262595 829.00 7.15411014e-01 3.07916775e-01 7.78861772e-01 0.40644016 0.98459147 829.25 7.39138478e-01 3.46146145e-01 8.16175743e-01 0.43797599 0.98242390 829.50 8.27388789e-01 4.08468345e-01 9.22723467e-01 0.45858180 0.98107772 829.75 8.82555946e-01 4.48993488e-01 9.90202075e-01 0.47061692 0.97532249 830.00 9.70667136e-01 4.92561199e-01 1.08849034e+00 0.46958669 0.98713886 830.25 1.02130565e+00 4.87560721e-01 1.13171582e+00 0.44539625 0.98674556 830.50 1.11568916e+00 4.73720071e-01 1.21209447e+00 0.40153062 0.98968811 830.75 1.18626924e+00 4.49346957e-01 1.26852174e+00 0.36208929 0.98890645 831.00 1.27271495e+00 4.20952441e-01 1.34052389e+00 0.31942515 0.99118340 831.25 1.31922575e+00 4.06429150e-01 1.38041343e+00 0.29885450 0.98893552 831.50 1.38141747e+00 3.96071406e-01 1.43707578e+00 0.27922346 0.99153178 831.75 1.42835551e+00 3.81570506e-01 1.47844361e+00 0.26104400 0.98717838 832.00 1.53200685e+00 3.49829851e-01 1.57144071e+00 0.22449830 0.98957491 832.25 1.59485263e+00 3.40319435e-01 1.63075818e+00 0.21023309 0.98280083 832.50 1.70681976e+00 3.52687078e-01 1.74287747e+00 0.20376624 0.98046498 832.75 1.82222562e+00 3.39143638e-01 1.85351682e+00 0.18400971 0.97242307 833.00 1.99949540e+00 3.64367056e-01 2.03242348e+00 0.18025163 0.97901884 833.25 2.12078273e+00 4.07205360e-01 2.15952208e+00 0.18969841 0.95930574 833.50 2.41814202e+00 5.35028576e-01 2.47662400e+00 0.21774806 0.93621069 833.75 2.62267525e+00 9.00228398e-01 2.77287516e+00 0.33064718 0.81230120 834.00 2.92385181e+00 1.49200816e+00 3.28252917e+00 0.47184455 0.81274042 834.25 2.39889258e+00 2.22459064e+00 3.27161873e+00 0.74771674 0.59725678 834.50 9.85899316e-01 2.89466260e+00 3.05795177e+00 1.24252714 0.35720013 834.75 -1.02925950e+00 1.65272423e+00 1.94701631e+00 2.12778714 0.25756333 835.00 -1.70212427e+00 1.15930689e+00 2.05942212e+00 2.54366818 0.47048183 835.25 -1.35106056e+00 5.57555564e-01 1.46158573e+00 2.75020333 0.46533089 835.50 -1.43488300e+00 3.97820086e-01 1.48900975e+00 2.87113663 0.65604497 835.75 -1.08226227e+00 5.29135707e-02 1.08355501e+00 3.09273992 0.66176066 836.00 -9.35495185e-01 -4.39459589e-02 9.36526822e-01 -3.09465102 0.74669530 836.25 -7.98893320e-01 -2.11490678e-01 8.26413240e-01 -2.88279963 0.76977770 836.50 -7.76064106e-01 -2.66228837e-01 8.20459195e-01 -2.81112269 0.80629548 836.75 -7.03653379e-01 -3.49503156e-01 7.85672027e-01 -2.68059021 0.74746625 837.00 -7.48146102e-01 -3.73174305e-01 8.36051226e-01 -2.67890654 0.77537812 837.25 -8.76783511e-01 -3.43458610e-01 9.41654470e-01 -2.76823961 0.75809274 837.50 -9.72010624e-01 -2.93854672e-01 1.01545813e+00 -2.84801215 0.79272571 837.75 -1.08939391e+00 -1.93619429e-01 1.10646626e+00 -2.96569805 0.84346592 838.00 -9.60920104e-01 -1.05771260e-01 9.66723852e-01 -3.03196110 0.82591500 838.25 -8.41772665e-01 1.09507424e-01 8.48865770e-01 3.01222772 0.80421122 838.50 -8.06625194e-01 1.64964464e-01 8.23321005e-01 2.93986250 0.81113029 838.75 -7.89044584e-01 1.80868995e-01 8.09509079e-01 2.91626015 0.81319318 839.00 -7.38774756e-01 2.43052125e-01 7.77729050e-01 2.82375298 0.81722567 839.25 -6.34305635e-01 1.74728614e-01 6.57931400e-01 2.87279475 0.77836344 839.50 -6.39143743e-01 1.65314442e-01 6.60176937e-01 2.88848966 0.73349914 839.75 -7.85447793e-01 1.60242426e-01 8.01627015e-01 2.94034038 0.77105919 840.00 -8.21976077e-01 1.53357558e-01 8.36159800e-01 2.95714153 0.76678694 840.25 -7.53597384e-01 2.72046697e-01 8.01198117e-01 2.79515439 0.84672764 840.50 -7.54246384e-01 3.79425374e-01 8.44305171e-01 2.67550619 0.87589074 840.75 -6.98481774e-01 5.03388554e-01 8.60974346e-01 2.51711558 0.86340332 841.00 -6.65969881e-01 5.63310955e-01 8.72258628e-01 2.43951253 0.88290248 841.25 -6.83925771e-01 6.65028718e-01 9.53948456e-01 2.37020224 0.93244055 841.50 -6.25923952e-01 7.00974071e-01 9.39758182e-01 2.29969411 0.92308490 841.75 -5.34867402e-01 6.88338982e-01 8.71718815e-01 2.23138007 0.91921805 842.00 -4.80066969e-01 6.96302455e-01 8.45754931e-01 2.17440781 0.91835197 842.25 -4.08782421e-01 7.56534478e-01 8.59911323e-01 2.06618929 0.94771667 842.50 -3.74053418e-01 7.68718056e-01 8.54893800e-01 2.02366155 0.94286521 842.75 -3.28088400e-01 7.80160741e-01 8.46340818e-01 1.96888282 0.94141360 843.00 -2.65750309e-01 7.50726313e-01 7.96375052e-01 1.91102211 0.92790863 843.25 -2.22087789e-01 7.27917820e-01 7.61043586e-01 1.86692551 0.92869736 843.50 -2.35101869e-01 7.09244127e-01 7.47194834e-01 1.89088002 0.91583153 843.75 -2.29920585e-01 6.95087683e-01 7.32127286e-01 1.89024645 0.92372271 844.00 -2.01898946e-01 6.85880368e-01 7.14979065e-01 1.85707511 0.91459394 844.25 -1.84847293e-01 6.93475285e-01 7.17688298e-01 1.83129175 0.90193586 844.50 -2.14392052e-01 6.79445894e-01 7.12468016e-01 1.87644792 0.88170275 844.75 -2.29598426e-01 7.24505333e-01 7.60015404e-01 1.87768807 0.89868929 845.00 -1.87803358e-01 7.81901585e-01 8.04139410e-01 1.80651904 0.90219504 845.25 -1.43324699e-01 8.19404327e-01 8.31844589e-01 1.74395785 0.91412615 845.50 -3.62887524e-02 7.76488234e-01 7.77335739e-01 1.61749680 0.90177035 845.75 -5.50578351e-04 7.02576929e-01 7.02577144e-01 1.57157998 0.89901512 846.00 3.94081120e-02 6.88991453e-01 6.90117542e-01 1.51366177 0.86271754 846.25 2.90123090e-02 6.70386437e-01 6.71013926e-01 1.52754632 0.88283427 846.50 3.59228051e-02 6.64382612e-01 6.65353066e-01 1.51677947 0.91001545 846.75 2.59801541e-02 6.42993914e-01 6.43518564e-01 1.53041332 0.93194633 847.00 -1.85859816e-02 6.02564477e-01 6.02851050e-01 1.60163135 0.91717328 847.25 -3.27077170e-02 5.73196370e-01 5.74128795e-01 1.62779649 0.89840157 847.50 -6.00279176e-02 5.80176665e-01 5.83273790e-01 1.67389438 0.90032612 847.75 -6.27053115e-02 5.89278045e-01 5.92604902e-01 1.67680780 0.90636736 848.00 -8.80336935e-02 5.63450925e-01 5.70286662e-01 1.72578352 0.90937549 848.25 -1.00566384e-01 5.65663880e-01 5.74533918e-01 1.74674266 0.93037358 848.50 -1.33868787e-01 5.86798888e-01 6.01875225e-01 1.79509176 0.91043287 848.75 -1.72356174e-01 5.79516834e-01 6.04604343e-01 1.85987857 0.87670642 849.00 -2.42122338e-01 5.20486446e-01 5.74046485e-01 2.00620586 0.88518140 849.25 -2.87818625e-01 5.21954478e-01 5.96050365e-01 2.07473275 0.89010234 849.50 -3.62836234e-01 5.24896467e-01 6.38095944e-01 2.17562764 0.86573492 849.75 -4.12274658e-01 5.24032574e-01 6.66768725e-01 2.23739623 0.84855365 850.00 -4.81845383e-01 5.71990529e-01 7.47895807e-01 2.27086219 0.86606289 850.25 -5.33699809e-01 5.94339667e-01 7.98796048e-01 2.30248933 0.85216587 850.50 -6.30017745e-01 7.13359835e-01 9.51737681e-01 2.29423469 0.88995926 850.75 -6.70791826e-01 7.33796533e-01 9.94192650e-01 2.31136819 0.89697238 851.00 -7.81530739e-01 7.49736717e-01 1.08300297e+00 2.37695471 0.91511925 851.25 -8.41450593e-01 8.16407044e-01 1.17241612e+00 2.37129931 0.90869635 851.50 -1.03235383e+00 8.55923344e-01 1.34102916e+00 2.44935864 0.91526814 851.75 -1.01278001e+00 8.45831838e-01 1.31952827e+00 2.44577819 0.89564706 852.00 -1.12828881e+00 9.76351143e-01 1.49207815e+00 2.42826123 0.92307885 852.25 -1.26250149e+00 9.76497324e-01 1.59607551e+00 2.48324398 0.92537244 852.50 -1.29243399e+00 9.46520857e-01 1.60196360e+00 2.50948013 0.92896939 852.75 -1.33994285e+00 8.50077974e-01 1.58684574e+00 2.57625262 0.90932862 853.00 -1.51233103e+00 8.09395556e-01 1.71530356e+00 2.65018523 0.90706499 853.25 -1.63880558e+00 6.88274707e-01 1.77747175e+00 2.74397692 0.87195329 853.50 -1.86699920e+00 4.42987120e-01 1.91883392e+00 2.90862844 0.89253592 853.75 -2.02936402e+00 2.49665883e-01 2.04466413e+00 3.01918111 0.86475823 854.00 -2.09243592e+00 -1.87733099e-03 2.09243676e+00 -3.14069546 0.86220003 854.25 -2.21770020e+00 -4.61674381e-01 2.26524555e+00 -2.93634701 0.78648047 854.50 -2.53450097e+00 -1.25019164e+00 2.82607047e+00 -2.68334405 0.85379637 854.75 -2.58262241e+00 -1.60979280e+00 3.04325014e+00 -2.58420440 0.81247563 855.00 -2.65810324e+00 -2.09753837e+00 3.38602717e+00 -2.47352673 0.83927571 855.25 -2.68790394e+00 -2.30672702e+00 3.54200750e+00 -2.43236418 0.80543228 855.50 -2.68246653e+00 -2.69013682e+00 3.79900814e+00 -2.35476682 0.82110852 855.75 -2.20554777e+00 -2.85647064e+00 3.60885930e+00 -2.22830671 0.74695462 856.00 -1.67401702e+00 -3.09569631e+00 3.51932786e+00 -2.06651489 0.77320307 856.25 -1.59438342e+00 -3.14820574e+00 3.52891738e+00 -2.03958420 0.85659184 856.50 -1.35352780e+00 -3.26114823e+00 3.53088166e+00 -1.96420606 0.89846043 856.75 -1.01053720e+00 -3.05271258e+00 3.21562429e+00 -1.89047179 0.87449741 857.00 -1.09068328e+00 -3.10472892e+00 3.29073421e+00 -1.90862651 0.87503413 857.25 -5.11217903e-01 -3.11330723e+00 3.15500010e+00 -1.73354807 0.76883273 857.50 -2.60370659e-01 -3.10334594e+00 3.11424933e+00 -1.65450027 0.75535237 857.75 -2.37292570e-01 -3.09027701e+00 3.09937409e+00 -1.64743277 0.75289673 858.00 -3.77308143e-02 -2.75543359e+00 2.75569191e+00 -1.58448871 0.70022676 858.25 -3.20295075e-01 -2.55954214e+00 2.57950478e+00 -1.69528685 0.69928599 858.50 -2.95517471e-01 -2.59364832e+00 2.61042950e+00 -1.68424599 0.73243057 858.75 1.25077800e-01 -2.38825114e+00 2.39152419e+00 -1.51847200 0.74602653 859.00 1.76563150e-02 -2.21028112e+00 2.21035164e+00 -1.56280823 0.61149905 859.25 2.66288288e-01 -2.23759061e+00 2.25337995e+00 -1.45234671 0.59587355 859.50 4.41360034e-01 -2.29367898e+00 2.33575725e+00 -1.38069540 0.61498293 859.75 5.12559789e-01 -2.27882636e+00 2.33575836e+00 -1.34955546 0.52434685 860.00 5.77377960e-01 -2.01275047e+00 2.09392687e+00 -1.29143758 0.46732775 860.25 5.45330170e-01 -1.31979766e+00 1.42802341e+00 -1.17896930 0.26782703 860.50 6.56754225e-01 -9.39494345e-01 1.14628781e+00 -0.96070773 0.18627513 860.75 1.07186275e+00 -1.33398863e+00 1.71126135e+00 -0.89392356 0.25894051 861.00 7.50975954e-01 -1.12322463e+00 1.35114709e+00 -0.98146386 0.13334504 861.25 7.55008876e-01 -1.73605084e+00 1.89312200e+00 -1.16057008 0.21379668 861.50 5.66015698e-01 -1.10381976e+00 1.24048048e+00 -1.09697778 0.07740069 861.75 -3.80718188e-01 8.63581487e-01 9.43779277e-01 1.98602315 0.05273495 862.00 -1.37794262e+00 8.54986005e-01 1.62164328e+00 2.58625019 0.15907049 862.25 -1.83638628e+00 6.95814403e-01 1.96379028e+00 2.77940356 0.24835496 862.50 -1.73571249e+00 4.59229760e-01 1.79543583e+00 2.88294212 0.23693411 862.75 -1.67297469e+00 -2.36496021e-01 1.68960785e+00 -3.00116058 0.22717801 863.00 -2.21946295e+00 -7.29479591e-01 2.33626973e+00 -2.82404142 0.44500550 863.25 -2.59045068e+00 -7.98808127e-01 2.71081707e+00 -2.84247798 0.58163843 863.50 -2.21102654e+00 -9.60717238e-01 2.41072935e+00 -2.73169305 0.49911083 863.75 -2.07144881e+00 -1.15631012e+00 2.37233077e+00 -2.63246558 0.63528509 864.00 -1.89032954e+00 -9.28540608e-01 2.10607061e+00 -2.68500522 0.55160865 864.25 -1.76955255e+00 -6.10677253e-01 1.87196232e+00 -2.80928739 0.44367954 864.50 -1.66509717e+00 -1.00619390e+00 1.94550116e+00 -2.59802808 0.49655204 864.75 -1.92860665e+00 -1.00901896e+00 2.17661270e+00 -2.65956918 0.64931604 865.00 -1.97031958e+00 -6.80067490e-01 2.08438266e+00 -2.80923976 0.59570303 865.25 -1.85086634e+00 -6.09543705e-01 1.94865332e+00 -2.82345044 0.49253343 865.50 -1.43999660e+00 -8.70757542e-01 1.68279794e+00 -2.59772871 0.47402675 865.75 -1.66777368e+00 -9.54382578e-01 1.92153979e+00 -2.62182794 0.56583622 866.00 -1.63700911e+00 -8.89903995e-01 1.86325735e+00 -2.64366416 0.51804783 866.25 -1.68185082e+00 -1.02739097e+00 1.97082582e+00 -2.59321936 0.58330251 866.50 -1.82556332e+00 -1.21706225e+00 2.19406516e+00 -2.55358245 0.60242251 866.75 -1.80840843e+00 -1.20821988e+00 2.17488766e+00 -2.55258991 0.55587289 867.00 -1.38408697e+00 -1.17471178e+00 1.81539101e+00 -2.43783818 0.40614968 867.25 -1.03005612e+00 -1.07263590e+00 1.48713260e+00 -2.33594713 0.29017876 867.50 -1.41391109e+00 -1.85852670e-01 1.42607355e+00 -3.01089614 0.28039073 867.75 -1.56131321e+00 -1.01912824e-01 1.56463579e+00 -3.07641133 0.41389155 868.00 -1.94643491e+00 3.97708271e-02 1.94684118e+00 3.12116284 0.60822323 868.25 -1.90335917e+00 1.26274141e-01 1.90754326e+00 3.07534695 0.60919461 868.50 -1.89410911e+00 3.46653028e-01 1.92556943e+00 2.96057952 0.60669297 868.75 -1.91979581e+00 2.58772910e-01 1.93715755e+00 3.00760831 0.64323818 869.00 -1.83004292e+00 4.81335003e-01 1.89228446e+00 2.88439938 0.70070296 869.25 -1.74499976e+00 4.97888902e-01 1.81463978e+00 2.86365461 0.68635773 869.50 -1.77680886e+00 4.84701951e-01 1.84173443e+00 2.87527894 0.69711217 869.75 -1.89381065e+00 5.93356734e-01 1.98458837e+00 2.83796669 0.79993075 870.00 -1.82791262e+00 6.65658769e-01 1.94534474e+00 2.79235629 0.82830000 870.25 -1.66990192e+00 5.98676245e-01 1.77397454e+00 2.79735691 0.78916706 870.50 -1.40635141e+00 5.81148644e-01 1.52169577e+00 2.74973214 0.80794169 870.75 -1.30630504e+00 5.37701064e-01 1.41264125e+00 2.75110949 0.81699649 871.00 -1.30862315e+00 3.34281486e-01 1.35064379e+00 2.89149571 0.81391204 871.25 -1.30902095e+00 1.48720358e-01 1.31744206e+00 3.02846582 0.82689422 871.50 -1.30183799e+00 1.45212628e-01 1.30991177e+00 3.03050753 0.84590213 871.75 -1.22762698e+00 2.01242062e-01 1.24401221e+00 2.97911010 0.84388824 872.00 -1.17859282e+00 1.01848939e-01 1.18298531e+00 3.05539109 0.87013522 872.25 -1.15666578e+00 3.51667319e-02 1.15720025e+00 3.11119848 0.86933175 872.50 -1.19646697e+00 -7.13735002e-02 1.19859392e+00 -3.08200971 0.86171417 872.75 -1.22559686e+00 -8.48938733e-02 1.22853353e+00 -3.07243575 0.81738304 873.00 -1.12687542e+00 -1.06055536e-01 1.13185511e+00 -3.04775437 0.78947373 873.25 -1.20625590e+00 -1.32653594e-01 1.21352802e+00 -3.03206143 0.80193371 873.50 -1.19270415e+00 -1.93585296e-01 1.20831223e+00 -2.98068792 0.78423831 873.75 -1.18925076e+00 -2.65437257e-01 1.21851315e+00 -2.92199495 0.75264995 874.00 -1.27642724e+00 -3.68439858e-01 1.32853845e+00 -2.86058158 0.82295359 874.25 -1.37063675e+00 -5.34757115e-01 1.47126145e+00 -2.76960437 0.84827972 874.50 -1.49670554e+00 -6.24982007e-01 1.62195253e+00 -2.74603056 0.85504433 874.75 -1.65769506e+00 -5.69401741e-01 1.75276104e+00 -2.81072909 0.88347347 875.00 -1.81575908e+00 -4.27236400e-01 1.86534500e+00 -2.91050252 0.88092374 875.25 -1.94844453e+00 -5.42062544e-01 2.02244107e+00 -2.87025136 0.84100810 875.50 -2.04387562e+00 -7.17232898e-01 2.16606800e+00 -2.80410018 0.75441341 875.75 -2.03862397e+00 -8.81689081e-01 2.22111759e+00 -2.73339315 0.71977017 876.00 -2.02772414e+00 -9.01380399e-01 2.21904299e+00 -2.72329845 0.74229458 876.25 -2.04356268e+00 -6.32208494e-01 2.13912038e+00 -2.84156564 0.73469146 876.50 -2.22284403e+00 -5.69586251e-01 2.29465991e+00 -2.89074774 0.73896439 876.75 -2.55928782e+00 -7.80576326e-01 2.67567815e+00 -2.84555735 0.71089864 877.00 -2.67291280e+00 -9.00828066e-01 2.82063007e+00 -2.81652677 0.69261386 877.25 -2.87426023e+00 -8.05438021e-01 2.98497944e+00 -2.86837582 0.66183065 877.50 -2.89041755e+00 -6.62272292e-01 2.96531924e+00 -2.91635370 0.63425357 877.75 -3.28679364e+00 8.53718333e-03 3.28680473e+00 3.13899524 0.49400242 878.00 -3.17996595e+00 7.22301639e-01 3.26096659e+00 2.91824102 0.49793100 878.25 -3.30829975e+00 1.49334957e+00 3.62973004e+00 2.71757935 0.48958190 878.50 -3.23317249e+00 2.02109361e+00 3.81290228e+00 2.58291309 0.50214469 878.75 -2.31599432e+00 2.25405085e+00 3.23180676e+00 2.36974790 0.45615331 879.00 -2.01036296e+00 2.12630683e+00 2.92621598e+00 2.32817352 0.48088917 879.25 -1.87956968e+00 1.37288377e+00 2.32757213e+00 2.51073802 0.47446617 879.50 -1.27540570e+00 1.21311536e+00 1.76020129e+00 2.38122033 0.40496240 879.75 -1.14373378e+00 1.01409355e+00 1.52856557e+00 2.41620142 0.44769196 880.00 -1.18697113e+00 1.01300242e+00 1.56047248e+00 2.43510791 0.44674000 880.25 -1.36718412e+00 8.34958295e-01 1.60198245e+00 2.59333253 0.55070959 880.50 -1.52797489e+00 6.83973003e-01 1.67407477e+00 2.72070831 0.68202155 880.75 -1.51166235e+00 5.94491349e-01 1.62435926e+00 2.76690149 0.64967670 881.00 -1.66311738e+00 5.47449696e-01 1.75090279e+00 2.82359304 0.68400118 881.25 -1.89195204e+00 1.81055761e-01 1.90059562e+00 3.04618534 0.77417629 881.50 -1.77313808e+00 1.18815051e-01 1.77711442e+00 3.07468433 0.72540575 881.75 -1.56652376e+00 -4.25122482e-02 1.56710050e+00 -3.11446136 0.51285035 882.00 -1.45594543e+00 -2.42804786e-01 1.47605260e+00 -2.97634560 0.39617514 882.25 -1.00161395e+00 -5.18490830e-01 1.12785781e+00 -2.66392072 0.29179744 882.50 -7.56450311e-01 -5.31428909e-01 9.24464039e-01 -2.52917083 0.16801622 882.75 3.47018287e-01 -2.94510037e-01 4.55145969e-01 -0.70373152 0.01996631 883.00 5.85908461e-01 4.13479462e-01 7.17115047e-01 0.61454563 0.04878207 883.25 9.14743744e-02 1.34694753e+00 1.35005008e+00 1.50298809 0.26856089 883.50 1.55062093e-01 1.58015896e+00 1.58774891e+00 1.47297881 0.44996299 883.75 4.00472558e-01 1.55757788e+00 1.60823727e+00 1.31913494 0.54410746 884.00 9.90034274e-02 1.58737508e+00 1.59045947e+00 1.50850774 0.66699025 884.25 1.65376373e-02 1.52749828e+00 1.52758780e+00 1.55997013 0.69893164 884.50 -1.82044430e-01 1.45677449e+00 1.46810493e+00 1.69511592 0.73404870 884.75 -4.31366118e-01 1.47652947e+00 1.53825095e+00 1.85503459 0.79245645 885.00 -4.25479548e-01 1.53702192e+00 1.59482576e+00 1.84085448 0.79131263 885.25 -4.04794707e-01 1.42472463e+00 1.48111412e+00 1.84762267 0.80572662 885.50 -3.93850199e-01 1.42338965e+00 1.47687375e+00 1.84074121 0.82638016 885.75 -3.81588404e-01 1.50737180e+00 1.55492104e+00 1.81873577 0.89227404 886.00 -3.64169366e-01 1.38669200e+00 1.43371337e+00 1.82761443 0.86137396 886.25 -3.60396352e-01 1.28914239e+00 1.33857149e+00 1.84339964 0.86386946 886.50 -3.38038305e-01 1.22210023e+00 1.26799009e+00 1.84065353 0.89259383 886.75 -3.58304863e-01 1.17050823e+00 1.22412087e+00 1.86784962 0.89615291 887.00 -3.71753514e-01 1.07801648e+00 1.14031584e+00 1.90287544 0.89292694 887.25 -4.33234251e-01 1.02044596e+00 1.10860357e+00 1.97228901 0.90909487 887.50 -4.81193612e-01 9.55408719e-01 1.06974441e+00 2.03736135 0.87894601 887.75 -5.36710172e-01 8.61799087e-01 1.01526128e+00 2.12779676 0.86345915 888.00 -6.36454961e-01 7.52121748e-01 9.85272572e-01 2.27308754 0.89601297 888.25 -6.55636729e-01 7.62453365e-01 1.00558175e+00 2.28101217 0.90216086 888.50 -8.31112380e-01 8.87178651e-01 1.21566186e+00 2.32357697 0.91807080 888.75 -8.69814975e-01 9.13852836e-01 1.26162795e+00 2.33151001 0.92399816 889.00 -7.93058430e-01 9.13635131e-01 1.20982264e+00 2.28566239 0.91947281 889.25 -7.19152105e-01 9.00736176e-01 1.15260809e+00 2.24456384 0.93000290 889.50 -6.72614299e-01 8.83679905e-01 1.11054049e+00 2.22139629 0.91433493 889.75 -6.73200023e-01 8.62068715e-01 1.09378277e+00 2.23378955 0.90552815 890.00 -7.69347059e-01 7.75696101e-01 1.09251972e+00 2.35208522 0.91242620 890.25 -7.62871630e-01 7.56832959e-01 1.07460190e+00 2.36016805 0.91078434 890.50 -7.96631750e-01 7.19105612e-01 1.07318918e+00 2.40729743 0.84949422 890.75 -8.21091388e-01 7.24092776e-01 1.09476089e+00 2.41888702 0.85172919 891.00 -8.98276145e-01 7.50450371e-01 1.17050237e+00 2.44561596 0.92537091 891.25 -9.50773746e-01 7.24669657e-01 1.19545674e+00 2.49033587 0.92222570 891.50 -8.70090962e-01 7.66499007e-01 1.15955983e+00 2.41940760 0.90829428 891.75 -8.04627989e-01 7.42237865e-01 1.09468865e+00 2.39650589 0.91842910 892.00 -7.66205438e-01 7.57251330e-01 1.07726522e+00 2.36207192 0.93508419 892.25 -8.06330176e-01 7.53502501e-01 1.10360064e+00 2.39004908 0.93801242 892.50 -7.35071087e-01 6.53264737e-01 9.83404454e-01 2.41505047 0.91693100 892.75 -7.13017182e-01 6.33030846e-01 9.53478660e-01 2.41554779 0.91662844 893.00 -7.27033259e-01 5.86718142e-01 9.34245973e-01 2.46259605 0.92558600 893.25 -7.43375962e-01 5.49212942e-01 9.24252497e-01 2.50529226 0.92259639 893.50 -7.39549316e-01 5.12544609e-01 8.99797292e-01 2.53554640 0.91881733 893.75 -7.89617922e-01 4.69194803e-01 9.18498898e-01 2.60544519 0.94257593 894.00 -8.36811171e-01 4.45901150e-01 9.48198699e-01 2.65200582 0.96361754 894.25 -8.38698840e-01 4.60760963e-01 9.56930723e-01 2.63922869 0.95997841 894.50 -8.39118787e-01 4.64472961e-01 9.59090960e-01 2.63604738 0.95871230 894.75 -8.47713651e-01 4.20073204e-01 9.46086640e-01 2.68152208 0.95817806 895.00 -8.68486970e-01 4.28968001e-01 9.68650176e-01 2.68281631 0.95744408 895.25 -8.60844333e-01 3.98843685e-01 9.48751416e-01 2.70771978 0.94722024 895.50 -8.78962032e-01 4.05015458e-01 9.67787050e-01 2.70980345 0.95641031 895.75 -9.25927039e-01 4.09721477e-01 1.01252781e+00 2.72499432 0.95833729 896.00 -9.30579653e-01 3.96256457e-01 1.01143347e+00 2.73903037 0.96913100 896.25 -9.32078826e-01 3.65603245e-01 1.00121759e+00 2.76778946 0.95625306 896.50 -9.13051509e-01 3.75661948e-01 9.87311986e-01 2.75126699 0.94323579 896.75 -9.23743798e-01 3.40060425e-01 9.84349377e-01 2.78885606 0.93426833 897.00 -9.59547999e-01 3.16660002e-01 1.01044837e+00 2.82283648 0.94500950 897.25 -9.33882877e-01 2.68458151e-01 9.71703147e-01 2.86167564 0.93740473 897.50 -9.49379967e-01 2.46506262e-01 9.80860673e-01 2.88755270 0.93900720 897.75 -9.81781990e-01 2.57957527e-01 1.01510490e+00 2.88465588 0.94848838 898.00 -9.79763163e-01 2.40249872e-01 1.00878930e+00 2.90112521 0.95048200 898.25 -9.64569412e-01 2.40205373e-01 9.94028557e-01 2.89752845 0.92863851 898.50 -9.67211945e-01 2.25346231e-01 9.93116242e-01 2.91269074 0.93666465 898.75 -1.01239115e+00 2.09581233e-01 1.03385692e+00 2.93746007 0.94399782 899.00 -1.04173296e+00 1.88971337e-01 1.05873402e+00 2.96214308 0.95061444 899.25 -1.07774102e+00 1.16662033e-01 1.08403678e+00 3.03376568 0.94709371 899.50 -1.10844174e+00 5.98167888e-02 1.11005456e+00 3.08768019 0.93912984 899.75 -1.14555672e+00 1.54766260e-02 1.14566126e+00 3.12808334 0.94330333 900.00 -1.16112283e+00 -1.85574950e-02 1.16127111e+00 -3.12561164 0.93762998 900.25 -1.28673974e+00 2.86712944e-02 1.28705913e+00 3.11931422 0.92791889 900.50 -1.30573162e+00 8.32226668e-02 1.30838109e+00 3.07794232 0.91839442 900.75 -1.25943922e+00 1.04349486e-01 1.26375471e+00 3.05892754 0.88450448 901.00 -1.27029216e+00 1.30866590e-01 1.27701536e+00 3.03893395 0.91000358 901.25 -1.30658480e+00 2.36413097e-01 1.32780081e+00 2.96258963 0.93317995 901.50 -1.35356644e+00 2.59200723e-01 1.37816078e+00 2.95238854 0.93692558 901.75 -1.46551899e+00 2.28997791e-01 1.48330236e+00 2.98658895 0.90523262 902.00 -1.38584162e+00 2.91298580e-01 1.41612565e+00 2.93441260 0.89586556 902.25 -1.31957750e+00 3.28305643e-01 1.35980490e+00 2.89774746 0.95065888 902.50 -1.29520062e+00 3.25788481e-01 1.33554588e+00 2.89516967 0.95568008 902.75 -1.29006766e+00 3.17634635e-01 1.32859563e+00 2.90017905 0.96031795 903.00 -1.33831942e+00 3.18111227e-01 1.37560664e+00 2.90822870 0.95897671 903.25 -1.32321917e+00 3.50196921e-01 1.36877568e+00 2.88286906 0.96428877 903.50 -1.29903260e+00 3.35262114e-01 1.34159844e+00 2.88901825 0.96713767 903.75 -1.31556982e+00 2.95060505e-01 1.34825244e+00 2.92096036 0.97125230 904.00 -1.27813959e+00 2.77534249e-01 1.30792434e+00 2.92777268 0.97047492 904.25 -1.31582892e+00 2.47825009e-01 1.33896340e+00 2.95543204 0.96706829 904.50 -1.34284455e+00 2.82911471e-01 1.37232299e+00 2.93394857 0.95827547 904.75 -1.32990008e+00 3.10265232e-01 1.36561296e+00 2.91239266 0.95990425 905.00 -1.35074995e+00 2.81056213e-01 1.37968041e+00 2.93644563 0.96938297 905.25 -1.35741602e+00 2.65318068e-01 1.38310228e+00 2.94856802 0.97656489 905.50 -1.34479804e+00 2.47623104e-01 1.36740593e+00 2.95949831 0.97104902 905.75 -1.37697211e+00 2.16090146e-01 1.39382465e+00 2.98593083 0.98083512 906.00 -1.36803277e+00 1.86962486e-01 1.38074930e+00 3.00576888 0.97759682 906.25 -1.43931139e+00 1.47862702e-01 1.44688654e+00 3.03922023 0.96990247 906.50 -1.55279643e+00 2.07563090e-01 1.56660754e+00 3.00870985 0.96792618 906.75 -1.59911399e+00 2.57708148e-01 1.61974660e+00 2.98180964 0.97863842 907.00 -1.60025952e+00 2.82329864e-01 1.62497406e+00 2.96696219 0.97612972 907.25 -1.62090974e+00 2.70677579e-01 1.64335472e+00 2.97612828 0.96956509 907.50 -1.71908773e+00 2.93468066e-01 1.74395703e+00 2.97251105 0.96227723 907.75 -1.80280823e+00 3.63000930e-01 1.83899081e+00 2.94289643 0.97280128 908.00 -1.76635954e+00 4.18430452e-01 1.81524380e+00 2.90899168 0.96441195 908.25 -1.72612984e+00 4.69578476e-01 1.78886225e+00 2.87597927 0.96701302 908.50 -1.74433995e+00 5.34058569e-01 1.82426435e+00 2.84448811 0.94962682 908.75 -1.80107471e+00 6.61334917e-01 1.91865421e+00 2.78968746 0.94575105 909.00 -1.73768717e+00 7.42874035e-01 1.88981971e+00 2.73760018 0.93300978 909.25 -1.64351467e+00 8.41689786e-01 1.84650539e+00 2.66828983 0.91918344 909.50 -1.44488030e+00 8.86650683e-01 1.69523701e+00 2.59119686 0.91848362 909.75 -1.44026489e+00 8.84801615e-01 1.69033632e+00 2.59070111 0.92243968 910.00 -1.39651075e+00 7.96729634e-01 1.60779985e+00 2.62313588 0.93805847 910.25 -1.37824032e+00 8.38361012e-01 1.61319421e+00 2.59510451 0.93728919 910.50 -1.39647767e+00 9.42737901e-01 1.68490493e+00 2.54778618 0.94894261 910.75 -1.38762826e+00 1.07727792e+00 1.75671281e+00 2.48144299 0.95109318 911.00 -1.23642275e+00 1.18881476e+00 1.71523228e+00 2.37582221 0.95269298 911.25 -1.16851035e+00 1.22558442e+00 1.69336163e+00 2.33235949 0.94600472 911.50 -9.36297056e-01 1.28593119e+00 1.59068262e+00 2.20013885 0.92024195 911.75 -8.84619644e-01 1.29729993e+00 1.57020350e+00 2.16926624 0.93104025 912.00 -8.26398008e-01 1.22935862e+00 1.48130222e+00 2.16263289 0.91865834 912.25 -7.19631871e-01 1.16695461e+00 1.37100441e+00 2.12338680 0.88831716 912.50 -6.18037543e-01 1.06882586e+00 1.23464939e+00 2.09506192 0.82791007 912.75 -4.74427319e-01 1.02467695e+00 1.12917852e+00 2.00440983 0.74206062 913.00 -4.31653566e-01 8.38806770e-01 9.43356560e-01 2.04605899 0.68875693 913.25 -4.58899264e-01 8.21810407e-01 9.41254950e-01 2.08006610 0.68907266 913.50 -6.28485015e-01 8.33264157e-01 1.04370617e+00 2.21700847 0.70433062 913.75 -6.87375787e-01 7.67085946e-01 1.03000307e+00 2.30144537 0.71660990 914.00 -6.32042064e-01 5.37469216e-01 8.29668806e-01 2.43688419 0.59981745 914.25 -6.25443449e-01 5.87519764e-01 8.58113618e-01 2.38744963 0.64293661 914.50 -6.09452649e-01 6.96327417e-01 9.25367171e-01 2.28976146 0.70738550 914.75 -5.57214540e-01 6.75742228e-01 8.75851359e-01 2.26035611 0.70668298 915.00 -4.36636704e-01 5.88455395e-01 7.32756005e-01 2.20916081 0.62058825 915.25 -4.01822096e-01 5.23398113e-01 6.59853455e-01 2.22554079 0.56299957 915.50 -3.28688921e-01 4.42937162e-01 5.51570246e-01 2.20920076 0.47141881 915.75 -3.53837663e-01 3.81969016e-01 5.20674006e-01 2.31798111 0.48119166 916.00 -2.50864111e-01 2.65985587e-01 3.65624308e-01 2.32694582 0.35166567 916.25 -1.72783576e-01 1.87635208e-01 2.55070844e-01 2.31501119 0.22386183 916.50 -1.23154256e-01 1.24066786e-01 1.74812867e-01 2.35250336 0.15673779 916.75 -9.89939465e-02 1.65395123e-01 1.92757226e-01 2.11013426 0.22155010 917.00 -5.07255956e-02 1.75511094e-01 1.82694363e-01 1.85214627 0.24021346 917.25 2.06244489e-02 1.21515104e-01 1.23252945e-01 1.40267107 0.13699368 917.50 9.10929296e-02 6.37431113e-02 1.11180511e-01 0.61056430 0.13204277 917.75 1.91863582e-02 3.25504852e-02 3.77842617e-02 1.03818227 0.02133007 918.00 -1.58823336e-02 3.26802709e-02 3.63352257e-02 2.02317446 0.03036214 918.25 -8.22542458e-02 6.72897922e-02 1.06271713e-01 2.45592968 0.21014285 918.50 -1.53884568e-01 6.59420375e-02 1.67418077e-01 2.73674749 0.53665460 918.75 -2.01009030e-01 1.01054542e-01 2.24981445e-01 2.67575838 0.68943667 919.00 -2.37733813e-01 1.20105524e-01 2.66350714e-01 2.67378566 0.78961508 919.25 -2.87010268e-01 1.59144520e-01 3.28179634e-01 2.63530824 0.85124696 919.50 -3.13630272e-01 1.69327290e-01 3.56420649e-01 2.64654100 0.89836762 919.75 -3.35160189e-01 1.96141366e-01 3.88334634e-01 2.61211409 0.90044775 920.00 -3.41826156e-01 1.98984808e-01 3.95525062e-01 2.61442186 0.93129470 920.25 -3.54674318e-01 1.96187306e-01 4.05318802e-01 2.63633595 0.94709207 920.50 -3.65116086e-01 1.95823751e-01 4.14314733e-01 2.64930297 0.95551468 920.75 -3.89311555e-01 2.04045160e-01 4.39542846e-01 2.65883740 0.95101772 921.00 -4.05604956e-01 2.16379372e-01 4.59712316e-01 2.65152644 0.95118712 921.25 -4.52002385e-01 2.58737045e-01 5.20817640e-01 2.62169641 0.96292908 921.50 -4.61390895e-01 2.72332351e-01 5.35767177e-01 2.60837894 0.95803396 921.75 -4.56185406e-01 3.06154551e-01 5.49395789e-01 2.55051421 0.94003364 922.00 -4.55331857e-01 3.19936927e-01 5.56495047e-01 2.52909332 0.95179127 922.25 -4.49993882e-01 3.49485628e-01 5.69767232e-01 2.48125550 0.96750191 922.50 -4.46767131e-01 3.58079899e-01 5.72557493e-01 2.46594314 0.94605535 922.75 -3.64697205e-01 3.85781257e-01 5.30877791e-01 2.32810773 0.92013899 923.00 -3.37659681e-01 3.82786767e-01 5.10430964e-01 2.29363855 0.92710288 923.25 -3.46825675e-01 3.56737118e-01 4.97543385e-01 2.34210792 0.92186407 923.50 -3.16944148e-01 3.58762358e-01 4.78710792e-01 2.29438520 0.93206237 923.75 -3.07327696e-01 3.52092809e-01 4.67353891e-01 2.28841295 0.94867935 924.00 -3.21710993e-01 3.36614803e-01 4.65625910e-01 2.33355940 0.93912582 924.25 -3.22016185e-01 2.97672234e-01 4.38523867e-01 2.39545848 0.94883354 924.50 -3.23320693e-01 2.96736701e-01 4.38849565e-01 2.39904169 0.93015986 924.75 -3.53115695e-01 3.03534480e-01 4.65643506e-01 2.43155777 0.92417734 925.00 -3.62313425e-01 3.13195857e-01 4.78918221e-01 2.42877866 0.91576939 925.25 -3.52155347e-01 3.67975503e-01 5.09332268e-01 2.33422958 0.87921731 925.50 -3.17266186e-01 4.29676513e-01 5.34115848e-01 2.20682154 0.85193539 925.75 -2.22943866e-01 4.59545110e-01 5.10769690e-01 2.02248569 0.80347871 926.00 -1.70403416e-01 4.16880088e-01 4.50362445e-01 1.95883054 0.77574741 926.25 -1.24658930e-01 3.51305755e-01 3.72767464e-01 1.91178046 0.82057536 926.50 -1.46194681e-01 3.05562099e-01 3.38734529e-01 2.01705178 0.84458143 926.75 -1.73355752e-01 3.04705852e-01 3.50567929e-01 2.08805552 0.86858666 927.00 -1.77257240e-01 3.12534436e-01 3.59301966e-01 2.08671919 0.90476452 927.25 -1.93049480e-01 3.24020706e-01 3.77170412e-01 2.10811718 0.92231994 927.50 -2.09412665e-01 3.53066336e-01 4.10499089e-01 2.10614575 0.92191614 927.75 -2.22062916e-01 3.46070552e-01 4.11189452e-01 2.14129299 0.88199324 928.00 -2.41136929e-01 4.20885025e-01 4.85068266e-01 2.09107225 0.88028806 928.25 -2.43830963e-01 4.61293969e-01 5.21771659e-01 2.05704599 0.91307336 928.50 -2.42861270e-01 5.25863387e-01 5.79235616e-01 2.00344721 0.86367825 928.75 -2.52774362e-01 6.03584394e-01 6.54376801e-01 1.96739426 0.86036275 929.00 -2.16719387e-01 6.90731104e-01 7.23931455e-01 1.87482288 0.85366942 929.25 -2.19463042e-01 7.93567692e-01 8.23355153e-01 1.84060521 0.84816202 929.50 -3.88883517e-02 8.73860464e-01 8.74725336e-01 1.61526877 0.81688852 929.75 6.21670976e-02 9.52916499e-01 9.54942198e-01 1.50564988 0.82246008 930.00 1.84336774e-01 1.02900891e+00 1.04538959e+00 1.39353641 0.76180580 930.25 5.14938806e-01 9.80263458e-01 1.10728425e+00 1.08710905 0.72551418 930.50 8.51525576e-01 8.14156116e-01 1.17811120e+00 0.76296699 0.75405941 930.75 9.57272151e-01 6.79052143e-01 1.17366170e+00 0.61698135 0.79111399 931.00 9.14612224e-01 5.70405236e-01 1.07790429e+00 0.55763370 0.86220410 931.25 8.58571455e-01 5.57234732e-01 1.02355043e+00 0.57568982 0.85402997 931.50 8.88287751e-01 7.08549771e-01 1.13626489e+00 0.67331122 0.84102966 931.75 9.74944390e-01 8.70389067e-01 1.30694058e+00 0.72879937 0.87988718 932.00 1.36413001e+00 1.00917781e+00 1.69684723e+00 0.63693844 0.88393673 932.25 1.66137256e+00 9.09953122e-01 1.89424747e+00 0.50108463 0.85405793 932.50 1.77920366e+00 1.93865461e-01 1.78973447e+00 0.10853375 0.81283134 932.75 1.71986186e+00 -1.94438285e-01 1.73081804e+00 -0.11257659 0.83428513 933.00 1.64270859e+00 -4.92528558e-01 1.71495653e+00 -0.29129817 0.83848301 933.25 1.43267998e+00 -4.98415268e-01 1.51690135e+00 -0.33479399 0.79585114 933.50 1.23826123e+00 -5.08093899e-01 1.33845070e+00 -0.38937844 0.84514084 933.75 1.13152551e+00 -4.44059296e-01 1.21554047e+00 -0.37397482 0.86435634 934.00 1.03596442e+00 -3.69333135e-01 1.09983146e+00 -0.34246381 0.84116506 934.25 1.07580808e+00 -3.10333020e-01 1.11967389e+00 -0.28084096 0.83031379 934.50 1.13889872e+00 -3.02457283e-01 1.17837630e+00 -0.25957821 0.83925788 934.75 1.17034687e+00 -3.65103817e-01 1.22597414e+00 -0.30239471 0.83643880 935.00 1.21195838e+00 -3.74860297e-01 1.26860686e+00 -0.29996810 0.88142935 935.25 1.17023634e+00 -3.57664894e-01 1.22367368e+00 -0.29661824 0.86161841 935.50 1.21061522e+00 -4.59066693e-01 1.29473219e+00 -0.36244878 0.84031570 935.75 1.32514119e+00 -3.68037283e-01 1.37530019e+00 -0.27090657 0.84866924 936.00 1.36470792e+00 -3.48086603e-01 1.40840051e+00 -0.24973821 0.89894827 936.25 1.48026801e+00 -3.04088513e-01 1.51117941e+00 -0.20260931 0.86428475 936.50 1.70172287e+00 -3.39882956e-01 1.73533315e+00 -0.19713471 0.84278900 936.75 1.64020895e+00 -5.89780889e-01 1.74302235e+00 -0.34518078 0.80810467 937.00 1.54032496e+00 -9.90832242e-01 1.83148833e+00 -0.57162377 0.76400976 937.25 1.46014873e+00 -1.10148628e+00 1.82901786e+00 -0.64628938 0.74974785 937.50 1.22226929e+00 -1.06005670e+00 1.61791917e+00 -0.71444411 0.71004155 937.75 1.20319143e+00 -1.13701739e+00 1.65543896e+00 -0.75712871 0.72345944 938.00 1.25840503e+00 -1.45046531e+00 1.92026895e+00 -0.85618022 0.74537895 938.25 7.59691224e-01 -1.67147146e+00 1.83601405e+00 -1.14420281 0.72556640 938.50 3.98326125e-01 -1.67633571e+00 1.72301048e+00 -1.33750563 0.79136051 938.75 1.79732822e-01 -1.62946916e+00 1.63935159e+00 -1.46093896 0.76795403 939.00 -5.24604096e-02 -1.39698330e+00 1.39796797e+00 -1.60833133 0.65824910 939.25 -1.56313856e-01 -1.12376878e+00 1.13458816e+00 -1.70900738 0.68955375 939.50 -2.41648712e-01 -8.59907090e-01 8.93215709e-01 -1.84474806 0.65933255 939.75 -3.09857441e-01 -6.40728604e-01 7.11719592e-01 -2.02123944 0.57015849 940.00 -2.68468843e-01 -5.33076652e-01 5.96863667e-01 -2.03733691 0.51191725 940.25 -9.14744782e-02 -2.64277794e-01 2.79661103e-01 -1.90401935 0.16091325 940.50 5.07640934e-02 -1.36980986e-01 1.46084851e-01 -1.21589556 0.03587157 940.75 3.06111352e-01 3.05915437e-01 4.32768315e-01 0.78507805 0.22827302 941.00 4.86545580e-01 4.63504770e-01 6.71984578e-01 0.76115072 0.49213917 941.25 4.67041413e-01 4.35448368e-01 6.38547541e-01 0.75040591 0.46021271 941.50 5.37631536e-01 4.72461323e-01 7.15728559e-01 0.72096843 0.45630906 941.75 7.50182952e-01 5.69709724e-01 9.41989189e-01 0.64950759 0.50645290 942.00 8.14019460e-01 5.30820254e-01 9.71801329e-01 0.57784850 0.53828052 942.25 1.01176346e+00 3.68564477e-01 1.07680317e+00 0.34933873 0.54650406 942.50 1.11176144e+00 4.46508353e-01 1.19807479e+00 0.38190426 0.56271860 942.75 1.21087364e+00 6.19657641e-01 1.36021710e+00 0.47299882 0.59750997 943.00 1.24183280e+00 7.88282969e-01 1.47089726e+00 0.56559684 0.57429416 943.25 1.22789301e+00 9.17643674e-01 1.53290285e+00 0.64179137 0.66823775 943.50 1.19086997e+00 8.18528440e-01 1.44504674e+00 0.60217634 0.64065872 943.75 1.20726880e+00 7.11710575e-01 1.40143851e+00 0.53267888 0.68805140 944.00 1.23883008e+00 8.33100774e-01 1.49290216e+00 0.59202328 0.73004141 944.25 1.37324348e+00 8.72809098e-01 1.62714271e+00 0.56617281 0.71823403 944.50 1.33872007e+00 7.34847792e-01 1.52714528e+00 0.50201226 0.71727946 944.75 1.29566953e+00 8.34831880e-01 1.54133183e+00 0.57237520 0.67671944 945.00 1.33954289e+00 9.79250167e-01 1.65930891e+00 0.63125136 0.67558262 945.25 1.29678158e+00 7.69528863e-01 1.50791814e+00 0.53556308 0.66926534 945.50 1.11277093e+00 6.82875617e-01 1.30559498e+00 0.55041135 0.61743307 945.75 1.13659108e+00 9.15193060e-01 1.45925242e+00 0.67790894 0.67953850 946.00 1.08400367e+00 1.04507705e+00 1.50573902e+00 0.76711690 0.72692930 946.25 1.09177826e+00 1.16635188e+00 1.59760962e+00 0.81841067 0.82264014 946.50 1.14884019e+00 1.18421112e+00 1.64990598e+00 0.80055780 0.86904375 946.75 1.04337098e+00 9.95733877e-01 1.44225829e+00 0.76204064 0.83497999 947.00 8.92747970e-01 1.02920716e+00 1.36244865e+00 0.85627942 0.82671388 947.25 7.85263531e-01 9.48200780e-01 1.23114724e+00 0.87911796 0.85627226 947.50 6.53880549e-01 9.05333908e-01 1.11677628e+00 0.94529076 0.81504322 947.75 4.93649515e-01 1.01102815e+00 1.12510789e+00 1.11658083 0.82760286 948.00 4.02778179e-01 1.01325588e+00 1.09037505e+00 1.19243934 0.82595474 948.25 3.56931675e-01 9.09528970e-01 9.77058426e-01 1.19682782 0.82565745 948.50 3.29445253e-01 9.67370886e-01 1.02192984e+00 1.24255832 0.79074299 948.75 2.80398834e-01 8.77775434e-01 9.21473396e-01 1.26159912 0.75232886 949.00 1.75305241e-01 7.63261779e-01 7.83135027e-01 1.34503278 0.75843392 949.25 5.49369825e-02 7.22032632e-01 7.24119599e-01 1.49485608 0.68033878 949.50 -1.39403923e-01 7.62456911e-01 7.75096120e-01 1.75163408 0.56752814 949.75 -3.25613457e-01 9.10787248e-01 9.67242232e-01 1.91414380 0.66596460 950.00 -2.89918343e-01 9.86896051e-01 1.02859927e+00 1.85652580 0.62211062 950.25 -2.65372089e-01 9.51349098e-01 9.87667683e-01 1.84282452 0.54677192 950.50 -5.48894145e-01 8.92147995e-01 1.04747927e+00 2.12235374 0.55372713 950.75 -5.82411162e-01 9.50630954e-01 1.11485514e+00 2.12047085 0.57613882 951.00 -7.06674347e-01 9.58150962e-01 1.19056369e+00 2.20627502 0.67111783 951.25 -7.63228736e-01 1.08600075e+00 1.32737174e+00 2.18339125 0.67360461 951.50 -8.20429321e-01 1.33893322e+00 1.57030138e+00 2.12053703 0.71493118 951.75 -9.97747748e-01 1.37914623e+00 1.70221764e+00 2.19708989 0.74906282 952.00 -1.13022391e+00 1.67616812e+00 2.02161956e+00 2.16405828 0.73182367 952.25 -1.09640712e+00 1.99961995e+00 2.28047989e+00 2.07233938 0.76834140 952.50 -1.21641954e+00 1.89697164e+00 2.25348128e+00 2.14099074 0.73585347 952.75 -9.19760171e-01 2.10927627e+00 2.30108782e+00 1.98199316 0.74097184 953.00 -3.67999639e-01 2.37978502e+00 2.40806987e+00 1.72421682 0.79259467 953.25 -2.27952636e-01 2.27374217e+00 2.28514023e+00 1.67071685 0.79536323 953.50 -1.37984888e-01 1.99817621e+00 2.00293484e+00 1.63974229 0.79312303 953.75 -1.74704258e-01 1.86970154e+00 1.87784595e+00 1.66396545 0.78848479 954.00 -3.59103271e-01 1.79020186e+00 1.82586359e+00 1.76876272 0.77818732 954.25 -4.94081229e-01 1.87626993e+00 1.94023326e+00 1.82828252 0.81253179 954.50 -7.38331939e-01 2.00477847e+00 2.13641540e+00 1.92366784 0.82488605 954.75 -7.65561860e-01 2.13645162e+00 2.26947362e+00 1.91487569 0.82686592 955.00 -9.23854670e-01 2.15459695e+00 2.34431130e+00 1.97586689 0.77369898 955.25 -9.84259164e-01 2.61252544e+00 2.79178353e+00 1.93109708 0.80204132 955.50 -1.11560831e+00 3.34783619e+00 3.52882261e+00 1.89245626 0.85528498 955.75 -1.07235729e+00 3.42954444e+00 3.59328892e+00 1.87384712 0.79644851 956.00 -7.26750959e-01 3.60556214e+00 3.67807631e+00 1.76969513 0.70237008 956.25 -5.38673838e-01 3.66864078e+00 3.70797717e+00 1.71658655 0.70315539 956.50 -2.92257113e-01 4.15817016e+00 4.16842816e+00 1.64096596 0.77071655 956.75 -3.98393519e-01 4.28462171e+00 4.30310360e+00 1.66351194 0.76454033 957.00 -3.19204490e-01 4.59743961e+00 4.60850762e+00 1.64011601 0.75719670 957.25 3.16399217e-01 3.94436549e+00 3.95703521e+00 1.49075222 0.62092333 957.50 2.14430664e+00 3.67755619e+00 4.25704950e+00 1.04291149 0.65715131 957.75 2.54825280e+00 3.57169374e+00 4.38754926e+00 0.95109526 0.68803772 958.00 2.27456301e+00 3.11283609e+00 3.85530614e+00 0.93975921 0.57317780 958.25 2.41010399e+00 2.82992294e+00 3.71713130e+00 0.86534511 0.56794894 958.50 2.35480962e+00 2.43301368e+00 3.38595391e+00 0.80173066 0.58444644 958.75 1.97564025e+00 2.39109099e+00 3.10168834e+00 0.88025264 0.55719352 959.00 1.75329443e+00 2.27963375e+00 2.87589489e+00 0.91517511 0.52371160 959.25 1.49708904e+00 2.51014633e+00 2.92268886e+00 1.03301699 0.57657427 959.50 1.68510634e+00 2.81999292e+00 3.28510935e+00 1.03217513 0.65535959 959.75 1.40946517e+00 2.69382155e+00 3.04027410e+00 1.08874462 0.63818390 960.00 1.27005143e+00 2.72946043e+00 3.01047918e+00 1.13528193 0.64572484 960.25 1.39492683e+00 2.82573836e+00 3.15128833e+00 1.11224130 0.58686436 960.50 1.42333140e+00 2.90630677e+00 3.23612288e+00 1.11539127 0.58476983 960.75 1.43934928e+00 2.40507995e+00 2.80287993e+00 1.03150838 0.45930323 961.00 1.56444972e+00 1.93303675e+00 2.48679191e+00 0.89039686 0.38019740 961.25 1.61324176e+00 1.90319975e+00 2.49493853e+00 0.86766983 0.44763766 961.50 1.33628909e+00 1.49262197e+00 2.00339434e+00 0.84060458 0.34581384 961.75 1.36548037e+00 1.09634235e+00 1.75114339e+00 0.67650592 0.24683617 962.00 1.40633827e+00 1.63566144e+00 2.15712208e+00 0.86064151 0.31956297 962.25 1.00027677e+00 1.05678645e+00 1.45511210e+00 0.81286230 0.20311096 962.50 8.16929683e-01 8.51248303e-01 1.17982956e+00 0.80596778 0.12881496 962.75 5.50079921e-01 8.01777443e-01 9.72334813e-01 0.96947687 0.13974613 963.00 7.11211616e-01 6.40634346e-01 9.57201299e-01 0.73323745 0.17518911 963.25 7.77512530e-01 1.30521160e-01 7.88391722e-01 0.16631942 0.14993716 963.50 7.43358349e-01 -2.69265539e-02 7.43845867e-01 -0.03620701 0.12079858 963.75 6.68265229e-01 3.00022545e-02 6.68938377e-01 0.04486560 0.08127121 964.00 5.04477348e-01 -1.34233388e-01 5.22030648e-01 -0.26005840 0.06494665 964.25 5.60745485e-01 -5.30125423e-02 5.63245798e-01 -0.09425925 0.08093934 964.50 4.84215281e-01 8.38096794e-02 4.91414795e-01 0.17138552 0.05324246 964.75 2.35691078e-01 2.99164682e-01 3.80854029e-01 0.90351995 0.04004224 965.00 1.92301240e-01 2.28094343e-01 2.98340068e-01 0.87033480 0.03170304 965.25 1.43870401e-02 4.65944906e-01 4.66166969e-01 1.53992901 0.06493074 965.50 -2.13466259e-02 5.66655236e-01 5.67057170e-01 1.60844980 0.12479041 965.75 8.80629090e-02 6.39068992e-01 6.45107939e-01 1.43385997 0.19457012 966.00 1.04000887e-01 9.06348477e-01 9.12295866e-01 1.45654888 0.28060729 966.25 2.52369192e-01 8.98704079e-01 9.33466245e-01 1.29703244 0.27985222 966.50 2.74391256e-01 6.09721401e-01 6.68618537e-01 1.14791973 0.14159665 966.75 2.59740851e-02 5.55174684e-01 5.55781957e-01 1.52404499 0.07484154 967.00 9.77356451e-02 6.11836074e-01 6.19593123e-01 1.41239307 0.07911747 967.25 1.44649208e-01 7.76806064e-01 7.90158879e-01 1.38669467 0.14535348 967.50 8.16454311e-02 3.38379069e-01 3.48089601e-01 1.33403770 0.04096540 967.75 3.81535506e-01 3.20930896e-01 4.98563920e-01 0.69933723 0.10351500 968.00 2.61172814e-01 6.22092301e-01 6.74692574e-01 1.17331312 0.17009886 968.25 1.37928239e-01 9.41867217e-01 9.51912839e-01 1.42538860 0.33877684 968.50 3.04019317e-01 1.13802524e+00 1.17793429e+00 1.30974613 0.50101629 968.75 3.63715954e-01 1.09830484e+00 1.15696275e+00 1.25100196 0.55743877 969.00 2.54456316e-01 1.02281597e+00 1.05399266e+00 1.32696608 0.53811603 969.25 4.48022960e-01 1.12272872e+00 1.20881941e+00 1.19111067 0.55498042 969.50 8.11312846e-01 1.16620866e+00 1.42065871e+00 0.96297280 0.62909349 969.75 9.04647809e-01 1.00960941e+00 1.35561751e+00 0.84017482 0.52870203 970.00 7.16876275e-01 6.91868886e-01 9.96290193e-01 0.76764849 0.35514841 970.25 7.06264163e-01 8.36556708e-01 1.09482245e+00 0.86964911 0.41378846 970.50 8.13139883e-01 7.27458430e-01 1.09105098e+00 0.72983970 0.35060185 970.75 8.70427561e-01 7.06032759e-01 1.12077045e+00 0.68149275 0.40022914 971.00 1.09451895e+00 5.34648181e-01 1.21812167e+00 0.45438741 0.39883049 971.25 1.09639722e+00 -8.99571685e-02 1.10008143e+00 -0.08186460 0.30689494 971.50 8.27704579e-01 -2.28348862e-01 8.58625689e-01 -0.26918609 0.22774434 971.75 4.59315785e-01 -1.70372591e-01 4.89895713e-01 -0.35519498 0.10760903 972.00 3.91421511e-01 -2.65194838e-01 4.72799219e-01 -0.59547700 0.11716291 972.25 3.96315434e-01 -4.85790209e-01 6.26943419e-01 -0.88648560 0.21966723 972.50 1.64222907e-01 -5.17297767e-01 5.42739480e-01 -1.26339641 0.19181901 972.75 8.64237220e-03 -4.16467878e-01 4.16557540e-01 -1.55004771 0.12196846 973.00 6.49857837e-02 -2.83604094e-01 2.90954351e-01 -1.34554240 0.09378971 973.25 -5.24036204e-02 -1.75790108e-01 1.83434734e-01 -1.86051217 0.04223306 973.50 1.43147407e-01 1.07525733e-01 1.79033414e-01 0.64423920 0.03503402 973.75 6.39956422e-04 1.53309286e-01 1.53310622e-01 1.56662207 0.02724434 974.00 -7.68378697e-02 3.32558071e-01 3.41319394e-01 1.79786267 0.10961750 974.25 -1.13558472e-01 4.11227974e-01 4.26619236e-01 1.84022655 0.16205318 974.50 -1.32613148e-01 6.47426602e-01 6.60868711e-01 1.77283290 0.31578762 974.75 -2.38956141e-01 7.28100371e-01 7.66309459e-01 1.88791185 0.35129908 975.00 -4.16133176e-01 8.47083205e-01 9.43777927e-01 2.02742284 0.35609268 975.25 -4.43525948e-01 9.18391614e-01 1.01988157e+00 2.02070117 0.36305124 975.50 -3.59926076e-01 1.01497134e+00 1.07690000e+00 1.91157834 0.36783978 975.75 -2.74511620e-01 1.09059267e+00 1.12461060e+00 1.81738249 0.42571655 976.00 -3.62296083e-01 1.01577058e+00 1.07844718e+00 1.91340188 0.50633535 976.25 -2.81212313e-01 9.45095962e-01 9.86046014e-01 1.86000294 0.43247608 976.50 -2.68861234e-01 1.20874562e+00 1.23828605e+00 1.78966322 0.56363625 976.75 -2.18057602e-01 1.13034896e+00 1.15118978e+00 1.76136707 0.48032202 977.00 -1.80044247e-01 9.77155735e-01 9.93604178e-01 1.75300608 0.43328575 977.25 -2.84669645e-01 9.80168869e-01 1.02067028e+00 1.85344959 0.51128076 977.50 -2.72878264e-01 9.29363251e-01 9.68596200e-01 1.85638832 0.52476318 977.75 -2.86638331e-01 8.12043800e-01 8.61148458e-01 1.91012687 0.38918245 978.00 -3.75894770e-01 6.89120257e-01 7.84973635e-01 2.07015534 0.33584745 978.25 -4.18599793e-01 5.77058400e-01 7.12897036e-01 2.19836851 0.36405818 978.50 -4.45295127e-01 4.91515633e-01 6.63231007e-01 2.30689632 0.39688795 978.75 -3.64712362e-01 5.17041646e-01 6.32729934e-01 2.18512588 0.38953932 979.00 -2.83789011e-01 6.42672602e-01 7.02541298e-01 1.98662309 0.46648522 979.25 -2.61411639e-01 5.71584109e-01 6.28525607e-01 1.99974227 0.33537589 979.50 -3.44685964e-01 4.77008939e-01 5.88511633e-01 2.19652864 0.28713394 979.75 -3.35486791e-01 4.12503287e-01 5.31705134e-01 2.25359146 0.26330556 980.00 -2.77849603e-01 3.26011752e-01 4.28350400e-01 2.27660600 0.21826506 980.25 -4.61049298e-02 2.68414207e-01 2.72345096e-01 1.74090417 0.10212908 980.50 -3.34739104e-02 1.23225954e-01 1.27691575e-01 1.83604224 0.02475955 980.75 3.35588678e-02 -1.43157350e-01 1.47038174e-01 -1.34053460 0.01653562 981.00 2.88959004e-01 -2.58839268e-01 3.87936944e-01 -0.73047021 0.08720045 981.25 4.07198072e-01 -5.57586542e-01 6.90444076e-01 -0.94003152 0.15083435 981.50 4.74391787e-01 -6.76634433e-01 8.26366580e-01 -0.95932913 0.17839063 981.75 3.98004910e-01 -8.62870851e-01 9.50238924e-01 -1.13862091 0.29701460 982.00 4.35665555e-01 -9.40550071e-01 1.03655145e+00 -1.13701724 0.33061543 982.25 6.60584698e-01 -9.73812167e-01 1.17672524e+00 -0.97474937 0.30449269 982.50 6.57618913e-01 -8.82655020e-01 1.10070092e+00 -0.93047309 0.27141050 982.75 7.18895699e-02 -8.57545945e-01 8.60553983e-01 -1.48716014 0.16500971 983.00 -7.37740209e-02 -9.68949910e-01 9.71754359e-01 -1.64678783 0.20211301 983.25 2.77194200e-01 -4.37625809e-01 5.18027965e-01 -1.00617607 0.06536853 983.50 2.21836698e-01 -6.13038736e-02 2.30151441e-01 -0.26961794 0.01338992 983.75 1.38157061e-01 -2.77568238e-01 3.10050802e-01 -1.10895764 0.03481600 984.00 1.29825483e-01 -1.65075499e-01 2.10010896e-01 -0.90436541 0.02394047 984.25 -4.19611892e-02 1.19275048e-01 1.26440810e-01 1.90907550 0.01044437 984.50 -3.05201605e-01 1.85674103e-01 3.57243464e-01 2.59504480 0.06639188 984.75 -3.92679686e-01 2.29649526e-01 4.54902452e-01 2.61240478 0.10383463 985.00 -4.61454348e-01 1.16646544e-01 4.75969044e-01 2.89399900 0.11816646 985.25 -5.02599525e-01 6.88173243e-02 5.07288978e-01 3.00551604 0.16137271 985.50 -6.35329178e-01 1.70482178e-02 6.35557870e-01 3.11476541 0.26344327 985.75 -8.91924696e-01 -1.46983604e-01 9.03954558e-01 -2.97826684 0.48243615 986.00 -9.74654180e-01 -2.44687274e-01 1.00489931e+00 -2.89562567 0.55928747 986.25 -9.24213863e-01 -1.61773048e-01 9.38265306e-01 -2.96830959 0.63658220 986.50 -9.56988241e-01 -2.13920619e-01 9.80606203e-01 -2.92167280 0.71892752 986.75 -1.01638836e+00 -2.54310168e-01 1.04772084e+00 -2.89641669 0.82819595 987.00 -1.03118452e+00 -1.95825000e-01 1.04961371e+00 -2.95392436 0.86307345 987.25 -1.13745338e+00 -2.34287217e-01 1.16133143e+00 -2.93845834 0.93001299 987.50 -1.12852156e+00 -2.67478844e-01 1.15978698e+00 -2.90887007 0.88732785 987.75 -1.17698263e+00 -3.06737909e-01 1.21629612e+00 -2.88664975 0.79565756 988.00 -1.32152762e+00 -3.35081188e-01 1.36334685e+00 -2.89327003 0.76634848 988.25 -1.19602778e+00 -2.36221223e-01 1.21913203e+00 -2.94659747 0.70907569 988.50 -1.26533527e+00 -2.00993442e-01 1.28119932e+00 -2.98406279 0.71069878 988.75 -1.23263501e+00 -1.27110430e-01 1.23917154e+00 -3.03883497 0.62280705 989.00 -1.33604576e+00 3.59959424e-02 1.33653058e+00 3.11465702 0.64076561 989.25 -1.23911181e+00 1.18373833e-02 1.23916835e+00 3.13203982 0.58034768 989.50 -1.08212420e+00 1.90201607e-01 1.09871263e+00 2.96760298 0.54080692 989.75 -8.17534021e-01 2.62066381e-01 8.58510725e-01 2.83138439 0.46080750 990.00 -7.93611472e-01 2.53937597e-01 8.33248745e-01 2.83191037 0.44350126 990.25 -8.84053378e-01 3.33100596e-01 9.44725559e-01 2.78125545 0.56979708 990.50 -8.32768221e-01 4.80887445e-01 9.61642161e-01 2.61791419 0.56223626 990.75 -7.36078331e-01 3.35434206e-01 8.08905072e-01 2.71400500 0.52168270 991.00 -6.29775203e-01 1.99633424e-01 6.60658997e-01 2.83462108 0.41387962 991.25 -6.02221981e-01 3.14967777e-01 6.79614607e-01 2.65970739 0.43680585 991.50 -4.57904745e-01 3.55134170e-01 5.79479969e-01 2.48193068 0.37364423 991.75 -4.41960320e-01 3.20935907e-01 5.46194820e-01 2.51352157 0.41421887 992.00 -5.80631757e-01 3.75125451e-01 6.91268646e-01 2.56798916 0.61202262 992.25 -6.08734730e-01 3.96838532e-01 7.26662777e-01 2.56387789 0.69605486 992.50 -5.07880362e-01 3.13051025e-01 5.96609928e-01 2.58921070 0.60003443 992.75 -4.73980933e-01 3.55238573e-01 5.92327924e-01 2.49842531 0.54705886 993.00 -3.44404645e-01 3.67680079e-01 5.03788845e-01 2.32351980 0.50956293 993.25 -2.46915245e-01 3.17182391e-01 4.01959957e-01 2.23226726 0.44849244 993.50 -1.55874831e-01 2.85626765e-01 3.25391475e-01 2.07035461 0.29034568 993.75 -1.16900399e-01 3.13102401e-01 3.34213729e-01 1.92812978 0.34376262 994.00 -1.00116043e-01 2.67272475e-01 2.85408125e-01 1.92920240 0.40331324 994.25 -8.58493904e-02 2.79280719e-01 2.92177750e-01 1.86902329 0.40399901 994.50 -1.73593881e-02 3.01998486e-01 3.02496999e-01 1.62821485 0.36527018 994.75 2.34363567e-02 3.39356863e-01 3.40165170e-01 1.50184471 0.44468322 995.00 6.98233217e-03 3.04613411e-01 3.04693425e-01 1.54787839 0.32246095 995.25 2.08976221e-02 2.87952723e-01 2.88710030e-01 1.49835024 0.26679356 995.50 3.89196673e-02 3.07759340e-01 3.10210496e-01 1.44500271 0.31127870 995.75 -4.46466569e-02 3.06093733e-01 3.09332665e-01 1.71563438 0.33207720 996.00 -1.52216472e-01 3.14011864e-01 3.48960320e-01 2.02216767 0.40867511 996.25 -1.58821292e-01 3.92024518e-01 4.22974497e-01 1.95571815 0.43901666 996.50 -2.12899376e-01 4.13284927e-01 4.64898457e-01 2.04648202 0.48197436 996.75 -2.52645821e-01 4.11325985e-01 4.82720392e-01 2.12160822 0.48897727 997.00 -1.81117200e-01 4.84721083e-01 5.17453349e-01 1.92838502 0.64329542 997.25 -1.60911881e-01 4.89249209e-01 5.15031477e-01 1.88854756 0.71073962 997.50 -1.63706078e-01 5.13578097e-01 5.39038164e-01 1.87937038 0.68345614 997.75 -1.09326164e-01 4.79384632e-01 4.91692826e-01 1.79501685 0.55237049 998.00 -4.52360231e-02 4.58671977e-01 4.60897256e-01 1.66910233 0.55517347 998.25 1.96209568e-02 4.56269159e-01 4.56690845e-01 1.52781977 0.54626055 998.50 1.77248826e-01 3.88770450e-01 4.27269949e-01 1.14302896 0.56216066 998.75 2.20509373e-01 2.72953682e-01 3.50896133e-01 0.89127880 0.39879378 999.00 1.81049324e-01 2.10192566e-01 2.77416244e-01 0.85974991 0.28833104 999.25 1.71343846e-01 1.21076719e-01 2.09805352e-01 0.61516185 0.14791855 999.50 2.19175302e-01 6.71074140e-02 2.29218712e-01 0.29711817 0.17639532 999.75 1.67839575e-01 5.07000734e-02 1.75330033e-01 0.29335901 0.13505983 1000.00 1.58167697e-01 0.00000000e+00 1.58167697e-01 0.00000000 0.16204276