quiet ref 1421516000 21 Jan 2025 17:33:02 UTC (21 Jan 2025 18:33:02 CET) (anche 1 minuto prima) amplified loudspeaker in POS 1 (in front of CT) colored noise 8 - 2k Hz, level 0.004 using ENV_NOISE_MAG_WEB which is DAC ch 7 (because ENV_NOISE_WEB which is on ch 6 gives the usual spike!) 17:46:41 UTC - 17:56:09 POS 2 colored noise 8 - 2k Hz, level 0.004 18:00:58 - 18:06:01 Similar excitations ( just a bit more ALS_ACC, similar peaks in Hrec and B8 tapping SW holding point HOR - broadband excitation 1421518492 21 Jan 2025 18:14:34 UTC (21 Jan 2025 19:14:34 CET) 1421518564 21 Jan 2025 18:15:46 UTC (21 Jan 2025 19:15:46 CET) NE holding point - 200Hz and harmonics 1421518676 21 Jan 2025 18:17:38 UTC (21 Jan 2025 19:17:38 CET) 1421518738 21 Jan 2025 18:18:40 UTC (21 Jan 2025 19:18:40 CET) NW holding point - 175 Hz 1421518983 21 Jan 2025 18:22:45 UTC (21 Jan 2025 19:22:45 CET) 1421519049 21 Jan 2025 18:23:51 UTC (21 Jan 2025 19:23:51 CET) tapping SWEB flange with bastone soft - broadband in hrec 1421519386 21 Jan 2025 18:29:28 UTC (21 Jan 2025 19:29:28 CET) 60s tapping link pipe, middle, no noise in hrec 1421519730 21 Jan 2025 18:35:12 UTC (21 Jan 2025 19:35:12 CET) 1421519805 21 Jan 2025 18:36:27 UTC (21 Jan 2025 19:36:27 CET) repeat SWEB flange with hammer - no effect 1421519898 21 Jan 2025 18:38:00 UTC (21 Jan 2025 19:38:00 CET) 1421519972 21 Jan 2025 18:39:14 UTC (21 Jan 2025 19:39:14 CET) now with hammer perpendicular to pipe - peak at 165 Hz 1421520018 21 Jan 2025 18:40:00 UTC (21 Jan 2025 19:40:00 CET) 1421520066 21 Jan 2025 18:40:48 UTC (21 Jan 2025 19:40:48 CET) SWEB chamber - nothing in hrec 1421520431 21 Jan 2025 18:46:53 UTC (21 Jan 2025 19:46:53 CET) 1421520536 21 Jan 2025 18:48:38 UTC (21 Jan 2025 19:48:38 CET) Viewport AR side - hrec 90 Hz, B8 large noise at 230Hz - same frequencies excited in ENV_WE_ACC_Z (aslo in quiet) 1421520784 21 Jan 2025 18:52:46 UTC (21 Jan 2025 19:52:46 CET) 1421520865 21 Jan 2025 18:54:07 UTC (21 Jan 2025 19:54:07 CET) SWEB, blind flange SWEB W side - 112 Hz in B8, corresponding peak in ALS_ACC and ACC_Z 1421521294 21 Jan 2025 19:01:16 UTC (21 Jan 2025 20:01:16 CET) 1421521367 21 Jan 2025 19:02:29 UTC (21 Jan 2025 20:02:29 CET) WE tower belly, W side - 90 Hz and 167 peaks in Hrec and B8 photodiode, very similar to tapping viewport 1421521634 21 Jan 2025 19:06:56 UTC (21 Jan 2025 20:06:56 CET) 1421521719 21 Jan 2025 19:08:21 UTC (21 Jan 2025 20:08:21 CET) Beating 123, 123.2 19:23 1421522815 21 Jan 2025 19:26:37 UTC (21 Jan 2025 20:26:37 CET) beating 133, 133.2 1421522919 21 Jan 2025 19:28:21 UTC (21 Jan 2025 20:28:21 CET) beating 123.5 123.7 1421523128 21 Jan 2025 19:31:50 UTC (21 Jan 2025 20:31:50 CET) beating 123.5 123.6 (piu lento) 19:37 UTC to 19:40 beating 95, 95.1 19:41:44 to beating 120, 120.1 Hz 1421523874 21 Jan 2025 19:44:16 UTC (21 Jan 2025 20:44:16 CET) beating 105.8, 105.9 (a peak at 105.8 was excited when doing acoustic injections) 1421524215 21 Jan 2025 19:49:57 UTC (21 Jan 2025 20:49:57 CET) beating 192.9, 193.0 - non modula... 1421524352 21 Jan 2025 19:52:14 UTC (21 Jan 2025 20:52:14 CET) 1421524496 21 Jan 2025 19:54:38 UTC (21 Jan 2025 20:54:38 CET)