#------------------------------------------------------------------# Server /virgoLog/VirgoOnline/DET_Img_CEB - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m09-UTC - Host rtpc12.virgo.infn.it 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SPRB_B4_Cam1 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SDB2_B1_Cam 2025-01-03-05h03m40-UTC>WARNING-3 incomplete image buffers since the last 10.0 seconds on camera ALS_WE_Cam1 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SDB2_B1s2_Cam 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SPRB_B4_Cam2 2025-01-03-05h03m45-UTC>ERROR..-1 missing images since the last 10 seconds from camera ALS_WE_Cam1 (GPS: 1419915844) DET_Img_CEB: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/DET_Img_End - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-12-10-11h06m26-UTC - Host rtpc14.virgo.infn.it 2025-01-03-05h03m39-UTC>ERROR..-1 missing images since the last 10 seconds from camera SWEB_B8_Cam2 (GPS: 1419915838) 2025-01-03-05h03m44-UTC>WARNING-4 incomplete image buffers since the last 10.0 seconds on camera SWEB_B8_Cam1 2025-01-03-05h03m44-UTC>WARNING-4 incomplete image buffers since the last 10.0 seconds on camera SNEB_B7_Cam2 2025-01-03-05h03m44-UTC>WARNING-3 incomplete image buffers since the last 10.0 seconds on camera SNEB_B7_Cam1 2025-01-03-05h03m44-UTC>WARNING-3 incomplete image buffers since the last 10.0 seconds on camera SWEB_B8_Cam2 DET_Img_End: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FDS_Img - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m10-UTC - Host rtpc7.virgo.infn.it 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SQB1_Cam1 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera FCEB_IR_Cam 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera SQB1_Cam0 2025-01-03-05h03m40-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera EQB2_IR_Cam 2025-01-03-05h03m45-UTC>ERROR..-1 missing images since the last 10 seconds from camera EQB2_IR_Cam (GPS: 1419915844) FDS_Img: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/INJ_Img - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m08-UTC - Host rtpc11.virgo.infn.it 2025-01-03-05h03m41-UTC>WARNING-4 incomplete image buffers since the last 10.0 seconds on camera SIB2_RFC_ref_Cam 2025-01-03-05h03m41-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera INJ_IMC_ref_Cam 2025-01-03-05h03m41-UTC>WARNING-4 incomplete image buffers since the last 10.0 seconds on camera SIB2_B2_Cam 2025-01-03-05h03m43-UTC>ERROR..-1 missing images since the last 10 seconds from camera PSL_PMC_ref_Cam (GPS: 1419915842) INJ_Img: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/PAY_Img - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m07-UTC - Host rtpc14.virgo.infn.it 2025-01-03-05h03m40-UTC>ERROR..-2 missing images since the last 10 seconds from camera NE_Cam (GPS: 1419915839) 2025-01-03-05h03m43-UTC>WARNING-5 incomplete image buffers since the last 10.0 seconds on camera SR_Cam 2025-01-03-05h03m43-UTC>WARNING-2 incomplete image buffers since the last 10.0 seconds on camera NI_CP_Cam 2025-01-03-05h03m43-UTC>WARNING-1 incomplete image buffers since the last 10.0 seconds on camera NE_Cam PAY_Img: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/PAY_Img_50Hz - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m14-UTC - Host rtpc15.virgo.infn.it 2025-01-03-05h03m40-UTC>WARNING-20 incomplete image buffers since the last 10.0 seconds on camera WI_Cam 2025-01-03-05h03m40-UTC>WARNING-21 incomplete image buffers since the last 10.0 seconds on camera WE_Cam PAY_Img_50Hz: from 0.000000 to 0.000000 - total missing second: 0 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/ALS_CEB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m46-UTC - Host rtpc10.virgo.infn.it ALS_CEB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/ALS_NEB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m46-UTC - Host rtpc22.virgo.infn.it ALS_NEB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/ALS_WEB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m46-UTC - Host rtpc24.virgo.infn.it ALS_WEB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FDS_Img_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m44-UTC - Host rtpc7.virgo.infn.it FDS_Img_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/INJ_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc19.virgo.infn.it INJ_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/ISC_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-12-04-10h28m26-UTC - Host rtpc20.virgo.infn.it ISC_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SDB2_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc13.virgo.infn.it SDB2_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SDB_EDB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc1.virgo.infn.it SDB_EDB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SIB2_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc18.virgo.infn.it SIB2_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SNEB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc8.virgo.infn.it SNEB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SPRB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc6.virgo.infn.it SPRB_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SQB1_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc2.virgo.infn.it SQB1_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SQB2_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc3.virgo.infn.it SQB2_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SQZ_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc23.virgo.infn.it SQZ_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SSFS_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc21.virgo.infn.it SSFS_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SUSP_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-12-04-14h19m15-UTC - Host rtpc4.virgo.infn.it SUSP_Fb: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/SWEB_Fb - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m47-UTC - Host rtpc9.virgo.infn.it 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilder::ControlMerging] frame: 1419915862.000000000: merging is triggered on timeout (internal 1419915862.360135050 > max 1419915862.360000000) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Tpro: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Photodiodes_DAQ_10000Hz: 1641/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Quadrants_DAQ_10000Hz: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Quadrants_DAQ_2000Hz: 328/400 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_LC_DAQ_10000Hz: 1641/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_SBE_DAQ_10000Hz: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_PSD_sensing_DAQ_10000Hz: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_SBE_DAQ_10Hz: 1/2 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Photodiodes_DAQ_100Hz: 16/20 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_LC_DAQ_10Hz: 1/2 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_LC_DAQ_1000Hz: 164/200 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_DEMOD_B8_Monitoring: 9/10 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_ADC_PSD_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_MezzPD_B8_Slow: 821/1000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_ADC_SBE0_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_ADC_SBE1_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_ADC_MONI0_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_PCAL2_1: 3284/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Photodiodes_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_Quadrants_DAQ_20000Hz: 3284/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_PSD_sensing_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_LC_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_SBE_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_PCal_fast_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_DEMOD_ENV_Monitoring: 9/10 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_MezzPD_B8_1: 8210/10000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_TIMING_moni_DAQ_20000Hz: 3284/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_TIMING_moni_DAQ_100Hz: 16/20 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_TIMING_moni_DAQ_10Hz: 1/2 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source TCS_HWS_WE_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source TCS_HWS_WE_DAQ_100Hz: 16/20 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_NCAL_TCS_0: 17/20 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_NCal_DAQ_20000Hz: 3283/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI0_0: 165/200 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI0_1: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI1_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI2_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI3_0: 1642/2000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI3_1: 3284/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source WEB_ADC_MONI4_0: 165/200 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TfbSubFrame::Fill] GPS: 1419915862.000000000 - Source SWEB_ADC_MONI0_1: 3284/4000 missing packet(s), 0 data break(s) (missing data are at the end of the vector) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Quadrants_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3284 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Quadrants_DAQ_10000Hz: packet rejected: merging already done (packet: 1419915862.199935060 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_TIMING_moni_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3284 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_MezzPD_B8_1: packet rejected: merging already done (packet: 1419915862.199980010 < frame in construction: 1419915862.400000000) (8210 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_ADC_MONI0_1: packet rejected: merging already done (packet: 1419915862.199950010 < frame in construction: 1419915862.400000000) (3284 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI3_1: packet rejected: merging already done (packet: 1419915862.199954010 < frame in construction: 1419915862.400000000) (3284 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_PCAL2_1: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (3284 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Tpro: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] TCS_HWS_WE_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_PSD_sensing_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_PSD_sensing_DAQ_10000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_NCal_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Photodiodes_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_SBE_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_SBE_DAQ_10000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_PCal_fast_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_LC_DAQ_20000Hz: packet rejected: merging already done (packet: 1419915862.199985060 < frame in construction: 1419915862.400000000) (3283 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_ADC_SBE0_0: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI0_1: packet rejected: merging already done (packet: 1419915862.199949010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_ADC_MONI0_0: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_ADC_SBE1_0: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI1_0: packet rejected: merging already done (packet: 1419915862.199949010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI2_0: packet rejected: merging already done (packet: 1419915862.199949010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_ADC_PSD_0: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI3_0: packet rejected: merging already done (packet: 1419915862.199949010 < frame in construction: 1419915862.400000000) (1642 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Photodiodes_DAQ_10000Hz: packet rejected: merging already done (packet: 1419915862.199935060 < frame in construction: 1419915862.400000000) (1641 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_LC_DAQ_10000Hz: packet rejected: merging already done (packet: 1419915862.199935060 < frame in construction: 1419915862.400000000) (1641 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI4_0: packet rejected: merging already done (packet: 1419915862.199048790 < frame in construction: 1419915862.400000000) (165 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_MezzPD_B8_Slow: packet rejected: merging already done (packet: 1419915862.199980050 < frame in construction: 1419915862.400000000) (821 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_MONI0_0: packet rejected: merging already done (packet: 1419915862.199999010 < frame in construction: 1419915862.400000000) (165 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_LC_DAQ_1000Hz: packet rejected: merging already done (packet: 1419915862.199035080 < frame in construction: 1419915862.400000000) (164 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Quadrants_DAQ_2000Hz: packet rejected: merging already done (packet: 1419915862.199535070 < frame in construction: 1419915862.400000000) (328 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_DEMOD_ENV_Monitoring: packet rejected: merging already done (packet: 1419915862.196820080 < frame in construction: 1419915862.400000000) (9 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_DEMOD_B8_Monitoring: packet rejected: merging already done (packet: 1419915862.199401080 < frame in construction: 1419915862.400000000) (9 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_ADC_NCAL_TCS_0: packet rejected: merging already done (packet: 1419915862.190999010 < frame in construction: 1419915862.400000000) (17 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_Photodiodes_DAQ_100Hz: packet rejected: merging already done (packet: 1419915862.190035080 < frame in construction: 1419915862.400000000) (16 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_TIMING_moni_DAQ_100Hz: packet rejected: merging already done (packet: 1419915862.190035080 < frame in construction: 1419915862.400000000) (16 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] TCS_HWS_WE_DAQ_100Hz: packet rejected: merging already done (packet: 1419915862.190085080 < frame in construction: 1419915862.400000000) (16 times) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_LC_DAQ_10Hz: packet rejected: merging already done (packet: 1419915862.100035110 < frame in construction: 1419915862.400000000) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] WEB_TIMING_moni_DAQ_10Hz: packet rejected: merging already done (packet: 1419915862.100035110 < frame in construction: 1419915862.400000000) 2025-01-03-05h04m04-UTC>WARNING-[TolmFrameBuilderFrontEnd] SWEB_SBE_DAQ_10Hz: packet rejected: merging already done (packet: 1419915862.100085110 < frame in construction: 1419915862.400000000) 2025-01-03-05h04m13-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915860.0) is dropped 2025-01-03-05h04m14-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915860.200000000) is dropped 2025-01-03-05h04m16-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915860.400000000) is dropped 2025-01-03-05h04m16-UTC>ERROR..-[TolmFrameBuilder::FrontEnd] Rtai DAQ FIFO overrun -> acquisition is reset 2025-01-03-05h04m17-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915860.600000000) is dropped 2025-01-03-05h04m17-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915860.800000000) is dropped 2025-01-03-05h04m17-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915861.0) is dropped 2025-01-03-05h04m17-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915861.200000000) is dropped 2025-01-03-05h04m17-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915861.400000000) is dropped 2025-01-03-05h04m18-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915861.600000000) is dropped 2025-01-03-05h04m18-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915861.800000000) is dropped 2025-01-03-05h04m18-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915862.0) is dropped 2025-01-03-05h04m18-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915862.800000000) is dropped 2025-01-03-05h04m18-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915863.800000000) is dropped 2025-01-03-05h04m19-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915864.800000000) is dropped 2025-01-03-05h04m19-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915865.800000000) is dropped 2025-01-03-05h04m19-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915866.800000000) is dropped 2025-01-03-05h04m19-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915867.800000000) is dropped 2025-01-03-05h04m19-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915868.800000000) is dropped 2025-01-03-05h04m20-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915869.800000000) is dropped 2025-01-03-05h04m20-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915870.800000000) is dropped 2025-01-03-05h04m20-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915871.800000000) is dropped 2025-01-03-05h04m20-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915872.800000000) is dropped 2025-01-03-05h04m20-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915873.800000000) is dropped 2025-01-03-05h04m21-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915875.0) is dropped 2025-01-03-05h04m21-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915875.200000000) is dropped 2025-01-03-05h04m21-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915875.400000000) is dropped 2025-01-03-05h04m21-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915875.600000000) is dropped 2025-01-03-05h04m21-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915875.800000000) is dropped 2025-01-03-05h04m22-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915876.0) is dropped 2025-01-03-05h04m22-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915876.200000000) is dropped 2025-01-03-05h04m22-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915876.400000000) is dropped 2025-01-03-05h04m22-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915876.600000000) is dropped 2025-01-03-05h04m22-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915876.800000000) is dropped 2025-01-03-05h04m23-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915877.0) is dropped 2025-01-03-05h04m23-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915877.200000000) is dropped 2025-01-03-05h04m23-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915877.400000000) is dropped 2025-01-03-05h04m23-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915877.600000000) is dropped 2025-01-03-05h04m23-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915877.800000000) is dropped 2025-01-03-05h04m24-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915878.0) is dropped 2025-01-03-05h04m24-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915878.200000000) is dropped 2025-01-03-05h04m24-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915878.400000000) is dropped 2025-01-03-05h04m24-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915878.600000000) is dropped 2025-01-03-05h04m24-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915878.800000000) is dropped 2025-01-03-05h04m25-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915879.0) is dropped 2025-01-03-05h04m25-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915879.200000000) is dropped 2025-01-03-05h04m25-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915879.400000000) is dropped 2025-01-03-05h04m25-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915879.600000000) is dropped 2025-01-03-05h04m25-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915879.800000000) is dropped 2025-01-03-05h04m26-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915880.0) is dropped 2025-01-03-05h04m26-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915880.200000000) is dropped 2025-01-03-05h04m26-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915880.400000000) is dropped 2025-01-03-05h04m26-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915880.600000000) is dropped 2025-01-03-05h04m26-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915880.800000000) is dropped 2025-01-03-05h04m27-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915881.0) is dropped 2025-01-03-05h04m27-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915881.200000000) is dropped 2025-01-03-05h04m27-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915881.400000000) is dropped 2025-01-03-05h04m27-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915881.600000000) is dropped 2025-01-03-05h04m27-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915881.800000000) is dropped 2025-01-03-05h04m28-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915882.0) is dropped 2025-01-03-05h04m28-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915882.200000000) is dropped 2025-01-03-05h04m28-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915882.400000000) is dropped 2025-01-03-05h04m28-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915882.600000000) is dropped 2025-01-03-05h04m28-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915882.800000000) is dropped 2025-01-03-05h04m29-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915883.0) is dropped 2025-01-03-05h04m29-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915883.200000000) is dropped 2025-01-03-05h04m29-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915883.400000000) is dropped 2025-01-03-05h04m29-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915883.600000000) is dropped 2025-01-03-05h04m29-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915883.800000000) is dropped 2025-01-03-05h04m30-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915884.0) is dropped 2025-01-03-05h04m30-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915884.200000000) is dropped 2025-01-03-05h04m30-UTC>WARNING-[TfbOutputFifo::PushFrame] frame output FIFO is full: the oldest frame(1419915884.400000000) is dropped 2025-01-03-05h04m30-UTC>WARNING-FdIOPutFrame: miss 24.6 seconds between 1419915860.0 and 1419915884.6 2025-01-03-05h04m32-UTC>ERROR..-frame 1419915889 not send to FbmFFE: sending queue is full SWEB_Fb: from 1419915860.000000 to 1419915884.600000 - total missing second: 24.600000 - deltaGPS: 24.600000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsAlp - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m15-UTC - Host olserver52.virgo.infn.it FbsAlp: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsDet - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m14-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h03m47-UTC>INFO...-Cm> FillMasksPoll> WARNING name SQB1_MotSwitch - port 28007 - locked 0 - fds_id 34/34 - fd 45 - events 1 2025-01-03-05h03m52-UTC>INFO...-Cm> FillMasksPoll> WARNING name PCal_PowerSupply - port 28005 - locked 0 - fds_id 49/49 - fd 44 - events 1 2025-01-03-05h03m52-UTC>INFO...-Cm> FillMasksPoll> WARNING name TCS_PDU1 - port 28008 - locked 0 - fds_id 39/39 - fd 51 - events 1 2025-01-03-05h03m57-UTC>INFO...-Cm> FillMasksPoll> WARNING name SQB2_MotSwitch - port 28012 - locked 0 - fds_id 46/46 - fd 57 - events 1 2025-01-03-05h03m57-UTC>INFO...-Cm> FillMasksPoll> WARNING name SQB2_MotSwitch - port 28012 - locked 0 - fds_id 46/46 - fd 57 - events 1 2025-01-03-05h04m02-UTC>INFO...-Cm> FillMasksPoll> WARNING name PCal_PowerSupply - port 28005 - locked 0 - fds_id 49/49 - fd 44 - events 1 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsData> GPS:1419915888, sms SWEB_Photodiodes pending during 49 TiIrq 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Photodiodes, GPS:1419915836 too late - curGPS:1419915888 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Photodiodes, GPS:1419915837 too late - curGPS:1419915888 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Photodiodes, GPS:1419915838 too late - curGPS:1419915888 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Photodiodes, GPS:1419915839 too late - curGPS:1419915888 2025-01-03-05h04m33-UTC>WARNING-FbsCmSmsData> GPS:1419915891, sms SWEB_Quadrants pending during 7 TiIrq 2025-01-03-05h04m33-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Quadrants, GPS:1419915840 too late - curGPS:1419915891 2025-01-03-05h04m33-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Quadrants, GPS:1419915845 too late - curGPS:1419915891 2025-01-03-05h04m33-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Quadrants, GPS:1419915850 too late - curGPS:1419915891 2025-01-03-05h04m33-UTC>WARNING-FbsCmSmsCmPrint> sms SWEB_Quadrants, GPS:1419915855 too late - curGPS:1419915891 2025-01-03-05h35m02-UTC>ERROR..-FbsFrameSerFillUnit> smsServer PCal_NE_Ampli - units flags "alarms" 1 - missing value fields - first position 23 FbsDet: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsFDS - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m30-UTC - Host olserver52.virgo.infn.it FbsFDS: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsISC - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m30-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsData> GPS:1419915888, sms WEB_PCal_fast pending during 38 TiIrq 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms WEB_PCal_fast, GPS:1419915847 too late - curGPS:1419915888 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms WEB_PCal_fast, GPS:1419915848 too late - curGPS:1419915888 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms WEB_PCal_fast, GPS:1419915849 too late - curGPS:1419915888 FbsISC: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsMoni - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m30-UTC - Host olserver52.virgo.infn.it FbsMoni: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsPy - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-08-10-17h40m52-UTC - Host olserver53.virgo.infn.it FbsPy: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsStorage - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m09-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsData> GPS:1419915888, sms SMS_rtpc9 pending during 52 TiIrq 2025-01-03-05h04m30-UTC>WARNING-FbsCmSmsCmPrint> sms SMS_rtpc9, GPS:1419915836 too late - curGPS:1419915888 FbsStorage: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbsSusp - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h38m21-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsData> GPS:1419916572, sms CoilsSbNE pending during 5 TiIrq 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNE, GPS:1419916566 too late - curGPS:1419916572 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNE, GPS:1419916567 too late - curGPS:1419916572 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsData> GPS:1419916572, sms CoilsSbBS pending during 5 TiIrq 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbBS, GPS:1419916566 too late - curGPS:1419916572 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbBS, GPS:1419916567 too late - curGPS:1419916572 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsData> GPS:1419916572, sms CoilsSbWI pending during 5 TiIrq 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWI, GPS:1419916566 too late - curGPS:1419916572 2025-01-03-05h15m54-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWI, GPS:1419916567 too late - curGPS:1419916572 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsData> GPS:1419916573, sms CoilsSbNI pending during 6 TiIrq 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNI, GPS:1419916566 too late - curGPS:1419916573 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNI, GPS:1419916567 too late - curGPS:1419916573 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsData> GPS:1419916573, sms CoilsSbWE pending during 6 TiIrq 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWE, GPS:1419916566 too late - curGPS:1419916573 2025-01-03-05h15m55-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWE, GPS:1419916567 too late - curGPS:1419916573 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsData> GPS:1419917988, sms CoilsSbWE pending during 6 TiIrq 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWE, GPS:1419917981 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWE, GPS:1419917982 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsData> GPS:1419917988, sms CoilsSbNE pending during 6 TiIrq 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNE, GPS:1419917981 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNE, GPS:1419917982 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsData> GPS:1419917988, sms CoilsSbWI pending during 6 TiIrq 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWI, GPS:1419917981 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbWI, GPS:1419917982 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsData> GPS:1419917988, sms CoilsSbNI pending during 6 TiIrq 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNI, GPS:1419917981 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbNI, GPS:1419917982 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsData> GPS:1419917988, sms CoilsSbBS pending during 6 TiIrq 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbBS, GPS:1419917981 too late - curGPS:1419917988 2025-01-03-05h39m30-UTC>WARNING-FbsCmSmsCmPrint> sms CoilsSbBS, GPS:1419917982 too late - curGPS:1419917988 FbsSusp: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/Vacuum/FbsVac - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2025-01-07-17h24m20-UTC - Host olserver52.virgo.infn.it Open at 2024-11-22-10h26m03-UTC - Host olserver52.virgo.infn.it FbsVac: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbmFFE - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m32-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h04m10-UTC>WARNING-FdFrMrgr: Could not wait longer for frame parts, output 1419915859.8, nSources=15 first:SSFS_Fb 2025-01-03-05h04m10-UTC>WARNING-FdFrMrgr:1419915859.8 frames from SWEB_Fb start to be missing (isReady) 2025-01-03-05h04m10-UTC>WARNING-FdFrMrgr:1419915859.8 frames from SWEB_Fb start to be missing (out) 2025-01-03-05h04m30-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.8) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m31-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915884.6) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m31-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915884.8) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m31-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915885.0) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m31-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915885.2) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915885.4) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915885.6) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915885.8) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915886.0) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915886.2) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915886.4) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915886.6) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915886.8) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915887.0) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915887.2) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915887.4) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915887.6) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915887.8) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915888.0) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915888.2) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m32-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915888.4) from SWEB_Fb; last produced was 1419915888.4 2025-01-03-05h04m33-UTC>WARNING-FdFrMrgr:1419915889.4 frames from SWEB_Fb start to be missing (out) FbmFFE: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbmFE - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m21-UTC - Host olserver52.virgo.infn.it 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr: Could not wait longer for frame parts, output 1419915859.0, nSources=5 first:FbsFDS 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/ALS_SSFS_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/CAL_ISC_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/ENV_TCS_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/FDS_SQZ_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/INJ_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/INJ1_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/OTHERS_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SDB_EDB_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SIB2_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SDB2_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SNEB_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SPRB_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SUSP_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SUSP1_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SWEB_50Hz start to be missing (isReady) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/ALS_SSFS_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/CAL_ISC_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/ENV_TCS_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/FDS_SQZ_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/INJ_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/INJ1_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/OTHERS_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SDB_EDB_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SIB2_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SDB2_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SNEB_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SPRB_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SUSP_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SUSP1_50Hz start to be missing (out) 2025-01-03-05h04m09-UTC>WARNING-FdFrMrgr:1419915859.0 frames from /dev/shm/VirgoOnline/SWEB_50Hz start to be missing (out) 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915859.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915860.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m11-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915861.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915862.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915863.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m12-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915864.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915865.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915866.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SWEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/ENV_TCS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SUSP1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SUSP_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SPRB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/INJ1_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SNEB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SDB_EDB_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/FDS_SQZ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m13-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/CAL_ISC_50Hz; last produced was 1419915867.0 2025-01-03-05h04m14-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SDB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m14-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/SIB2_50Hz; last produced was 1419915867.0 2025-01-03-05h04m14-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/INJ_50Hz; last produced was 1419915867.0 2025-01-03-05h04m14-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/OTHERS_50Hz; last produced was 1419915867.0 2025-01-03-05h04m14-UTC>WARNING-FdFrMrgrFeed: reject too old frame (1419915867.0) from /dev/shm/VirgoOnline/ALS_SSFS_50Hz; last produced was 1419915867.0 FbmFE: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbmMain - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m12-UTC - Host olserver52.virgo.infn.it FbmMain: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbmAlp - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m05-UTC - Host olserver52.virgo.infn.it FbmAlp: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FbmSt - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-10-22-06h37m01-UTC - Host olserver52.virgo.infn.it FbmSt: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/Stol01IN_1 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-03-19-08h22m38-UTC - Host stol01.virgo.infn.it Stol01IN_1: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/Stol01RawFbm_10 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2025-01-07-07h38m24-UTC - Host stol01.virgo.infn.it Open at 2024-03-22-19h25m57-UTC - Host stol01.virgo.infn.it Stol01RawFbm_10: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FdWRawStol - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-03-19-08h22m48-UTC - Host stol01.virgo.infn.it FdWRawStol: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FmStol01 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-11-12-09h27m15-UTC - Host stol01.virgo.infn.it 2025-01-03-05h06m05-UTC>ERROR..-CHANNEL> At Jan03,25-05:04:22 1419915880, V1:SWEB_B8_DC missing 20, are back #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/Stol02IN_1 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-03-19-08h21m33-UTC - Host stol02.virgo.infn.it Stol02IN_1: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/Stol02RawFbm_10 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2025-01-07-07h37m47-UTC - Host stol02.virgo.infn.it Open at 2024-03-22-19h26m53-UTC - Host stol02.virgo.infn.it Stol02RawFbm_10: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FdWRawBack - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-03-19-08h21m42-UTC - Host stol02.virgo.infn.it FdWRawBack: from 0.000000 to 0.000000 - total missing second: 0.000000 - deltaGPS: 0.000000 #------------------------------------------------------------------# Server /virgoLog/VirgoOnline/FmStol02 - tag "^Open at|WARNING|ERROR" #------------------------------------------------------------------# Open at 2024-11-12-09h27m58-UTC - Host stol02.virgo.infn.it 2025-01-03-05h05m53-UTC>ERROR..-CHANNEL> At Jan03,25-05:04:22 1419915880, V1:SWEB_B8_DC missing 20, are back