DeRossi Tringali Fiori quiet reference 1407074648 07 Aug 2024 14:03:50 UTC (07 Aug 2024 16:03:50 CEST) injection 63 Hz line with Vibe-tribe start 16:08:50 volume is (too) large: seismic line at 63Hz is >100 the quiet reference and there are harmonics however nothing seen in Hrec bump shows up in B4, but that B4 signal becomes very noisy at low frequency 10s of good data: 14:08:53 to 14:09:03 ITF unlocks at about 14:10:13 new lock quiet reference 1407079820 07 Aug 2024 15:30:02 UTC (07 Aug 2024 17:30:02 CEST) injecting colored 50-70 volume 1407080550 07 Aug 2024 15:42:12 UTC (07 Aug 2024 17:42:12 CEST) 300s 15:55 UTC Camilla finished the first intervention: placed filter 3 (reduces transmitted light by factor 1000) in front of razor blade which blocks the beam from the scanning fabry perot closed a bit two irises on the beam to the phase camera moved shaker position on EPRB repeat the same injection, same volume 1407081530 07 Aug 2024 15:58:32 UTC (07 Aug 2024 17:58:32 CEST) 1407081917 07 Aug 2024 16:04:59 UTC (07 Aug 2024 18:04:59 CEST) no sensible reduction of B4 bump during injection. 16:20 UTC Camilla finished the second intervention: added filter 0.5 (transmits 30% of the light) on the phase camera path repeat again the same injection, same volume 1407082939 07 Aug 2024 16:22:01 UTC (07 Aug 2024 18:22:01 CEST) switched off lights under the platform ... and continue the shaking 1407083303 07 Aug 2024 16:28:05 UTC (07 Aug 2024 18:28:05 CEST) 1407083636 07 Aug 2024 16:33:38 UTC (07 Aug 2024 18:33:38 CEST) shaker on PR tower base, W side 70Hz line 1407084293 07 Aug 2024 16:44:35 UTC (07 Aug 2024 18:44:35 CEST) something in B4 but no in Hrec.... 60Hz line 1407084522 07 Aug 2024 16:48:24 UTC (07 Aug 2024 18:48:24 CEST) 1407084729 07 Aug 2024 16:51:51 UTC (07 Aug 2024 18:51:51 CEST) seen also in Hrec 65Hz line 1407084802 07 Aug 2024 16:53:04 UTC (07 Aug 2024 18:53:04 CEST) seen a bit in B4 64Hz 1407084935 07 Aug 2024 16:55:17 UTC (07 Aug 2024 18:55:17 CEST) seen in B4 a bit in Hrec as well ITF unlocked