Processing sensilines.C(1387076918,300,"itflines3.txt")... Removing lines in the band 83.6-91.6 Hz gains 0.189168 Mpc (from 48.8106 Mpc to 48.9997 Mpc) Removing lines in the band 94.5-102.5 Hz gains 0.335567 Mpc (from 48.8106 Mpc to 49.1461 Mpc) Removing lines in the band 99.6-107.6 Hz gains 0.102485 Mpc (from 48.8106 Mpc to 48.913 Mpc) Removing lines in the band 108.5-116.5 Hz gains 0.14573 Mpc (from 48.8106 Mpc to 48.9563 Mpc) Removing lines in the band 113.2-121.2 Hz gains 0.131936 Mpc (from 48.8106 Mpc to 48.9425 Mpc) Removing lines in the band 114.8-122.8 Hz gains 0.0509125 Mpc (from 48.8106 Mpc to 48.8615 Mpc) Removing lines in the band 116-124 Hz gains 0.124087 Mpc (from 48.8106 Mpc to 48.9347 Mpc) Removing lines in the band 118.8-126.8 Hz gains 0.11949 Mpc (from 48.8106 Mpc to 48.9301 Mpc) Removing lines in the band 129.4-137.4 Hz gains 0.044827 Mpc (from 48.8106 Mpc to 48.8554 Mpc) Removing lines in the band 153-161 Hz gains 0.0647247 Mpc (from 48.8106 Mpc to 48.8753 Mpc) Removing lines in the band 158.7-166.7 Hz gains 0.0285237 Mpc (from 48.8106 Mpc to 48.8391 Mpc) Removing lines in the band 161-169 Hz gains 0.0416108 Mpc (from 48.8106 Mpc to 48.8522 Mpc) Removing lines in the band 166.9-174.9 Hz gains 0.104156 Mpc (from 48.8106 Mpc to 48.9147 Mpc) Removing lines in the band 168.2-176.2 Hz gains 0.043177 Mpc (from 48.8106 Mpc to 48.8537 Mpc) Removing lines in the band 177.2-185.2 Hz gains 0.0533285 Mpc (from 48.8106 Mpc to 48.8639 Mpc) Removing lines in the band 180.2-188.2 Hz gains 0.0601463 Mpc (from 48.8106 Mpc to 48.8707 Mpc) Removing lines in the band 193-201 Hz gains 0.0959196 Mpc (from 48.8106 Mpc to 48.9065 Mpc) Removing lines in the band 198-206 Hz gains 0.0182267 Mpc (from 48.8106 Mpc to 48.8288 Mpc) Removing lines in the band 257.5-265.5 Hz gains 0.0210552 Mpc (from 48.8106 Mpc to 48.8316 Mpc) Removing lines in the band 268-276 Hz gains 0.0173179 Mpc (from 48.8106 Mpc to 48.8279 Mpc) Removing lines in the band 278.7-286.7 Hz gains 0.0263689 Mpc (from 48.8106 Mpc to 48.8369 Mpc) Removing lines in the band 305.6-313.6 Hz gains 0.00608125 Mpc (from 48.8106 Mpc to 48.8166 Mpc) Removing lines in the band 316.9-324.9 Hz gains 0.00935424 Mpc (from 48.8106 Mpc to 48.8199 Mpc) Removing lines in the band 397.2-405.2 Hz gains 0.0147242 Mpc (from 48.8106 Mpc to 48.8253 Mpc) Removing lines in the band 451-459 Hz gains -0.00575658 Mpc (from 48.8106 Mpc to 48.8048 Mpc) Removing lines in the band 500-508 Hz gains -5.42303e-05 Mpc (from 48.8106 Mpc to 48.8105 Mpc) Removing lines in the band 522.3-530.3 Hz gains 0.00405827 Mpc (from 48.8106 Mpc to 48.8146 Mpc) *** Removing the 27 frequency bands gains 1.30693 Mpc (from 48.8106 Mpc to 50.1175 Mpc) ***