Processing sensilines.C(1387067558,300,"itflines3.txt")... Removing lines in the band 83.6-91.6 Hz gains 0.289937 Mpc (from 44.5039 Mpc to 44.7938 Mpc) Removing lines in the band 94.5-102.5 Hz gains 0.19118 Mpc (from 44.5039 Mpc to 44.6951 Mpc) Removing lines in the band 99.6-107.6 Hz gains 0.104207 Mpc (from 44.5039 Mpc to 44.6081 Mpc) Removing lines in the band 108.5-116.5 Hz gains 0.294093 Mpc (from 44.5039 Mpc to 44.798 Mpc) Removing lines in the band 113.2-121.2 Hz gains 0.221264 Mpc (from 44.5039 Mpc to 44.7252 Mpc) Removing lines in the band 114.8-122.8 Hz gains -0.0347822 Mpc (from 44.5039 Mpc to 44.4691 Mpc) Removing lines in the band 116-124 Hz gains 0.307495 Mpc (from 44.5039 Mpc to 44.8114 Mpc) Removing lines in the band 118.8-126.8 Hz gains 0.169608 Mpc (from 44.5039 Mpc to 44.6735 Mpc) Removing lines in the band 129.4-137.4 Hz gains 0.055548 Mpc (from 44.5039 Mpc to 44.5594 Mpc) Removing lines in the band 153-161 Hz gains 0.13692 Mpc (from 44.5039 Mpc to 44.6408 Mpc) Removing lines in the band 158.7-166.7 Hz gains 0.0055795 Mpc (from 44.5039 Mpc to 44.5095 Mpc) Removing lines in the band 161-169 Hz gains 0.0673701 Mpc (from 44.5039 Mpc to 44.5713 Mpc) Removing lines in the band 166.9-174.9 Hz gains 0.00780675 Mpc (from 44.5039 Mpc to 44.5117 Mpc) Removing lines in the band 168.2-176.2 Hz gains 0.0528675 Mpc (from 44.5039 Mpc to 44.5568 Mpc) Removing lines in the band 177.2-185.2 Hz gains 0.146703 Mpc (from 44.5039 Mpc to 44.6506 Mpc) Removing lines in the band 180.2-188.2 Hz gains 0.0306948 Mpc (from 44.5039 Mpc to 44.5346 Mpc) Removing lines in the band 193-201 Hz gains 0.0951008 Mpc (from 44.5039 Mpc to 44.599 Mpc) Removing lines in the band 198-206 Hz gains 0.0475287 Mpc (from 44.5039 Mpc to 44.5514 Mpc) Removing lines in the band 257.5-265.5 Hz gains 0.0142858 Mpc (from 44.5039 Mpc to 44.5182 Mpc) Removing lines in the band 268-276 Hz gains 0.00150807 Mpc (from 44.5039 Mpc to 44.5054 Mpc) Removing lines in the band 278.7-286.7 Hz gains 0.0245152 Mpc (from 44.5039 Mpc to 44.5284 Mpc) Removing lines in the band 305.6-313.6 Hz gains 0.0195882 Mpc (from 44.5039 Mpc to 44.5235 Mpc) Removing lines in the band 316.9-324.9 Hz gains 0.00458182 Mpc (from 44.5039 Mpc to 44.5085 Mpc) Removing lines in the band 397.2-405.2 Hz gains 0.00466627 Mpc (from 44.5039 Mpc to 44.5086 Mpc) Removing lines in the band 451-459 Hz gains -0.00604717 Mpc (from 44.5039 Mpc to 44.4979 Mpc) Removing lines in the band 500-508 Hz gains -0.000134058 Mpc (from 44.5039 Mpc to 44.5038 Mpc) Removing lines in the band 522.3-530.3 Hz gains 0.00457929 Mpc (from 44.5039 Mpc to 44.5085 Mpc) *** Removing the 27 frequency bands gains 1.69629 Mpc (from 44.5039 Mpc to 46.2002 Mpc) ***