WEB quiet ref 1379702998 25 Sep 2023 18:49:40 UTC (25 Sep 2023 20:49:40 CEST) small coil axis EW 18:56:20 UTC start sweep (8-330, 5V, 600s) glitch (usual 30-min glitch) we excited a lot the crossbar mode (48Hz) then (when injecting at around 100hz) a broadband noise 20-60Hz increases, and stays up for some minutes... 19:07:09 UTC stop small coil axis NS 19:11:02 UTC start again we excite a lot the crossbar again we onset some noise 20-30Hz (but less evident) maybe we are disturbing the some control... we see the 48Hz crossbar keeps excited all along the sweep (!) maybe we are disturbng the WE marionette control 19:21:33 UTC stop small coil axis VERT 19:23:27 UTC start initially (up to 30Hz) there is evident non-lin behaviour in the current, means the amplifier is distorting (maybe because now the coil touchs the metal body of the tower and sees a different impedence of the coil) when the injection is above 100Hz, the broadband noise 20-60Hz increases again! the effect of the line in Hrec seems smaller. NOTE: the TF should be computed with respect to the magnetometer (ENV_WE_MAG) and not the current 19:34:33 stop NEB quiet reference 1379706936 25 Sep 2023 19:55:18 UTC (25 Sep 2023 21:55:18 CEST) unplug F7 motor crate 1379707207 25 Sep 2023 19:59:49 UTC (25 Sep 2023 21:59:49 CEST) no visble effect 20:09 UTC we unlocked ITF by moving around NE coil axis EW