quiet ref (also 1/2 before) 1367390422 06 May 2023 06:40:04 UTC (06 May 2023 08:40:04 CEST) DET EEroom coil base DT, axis EW lines 6:49:40 UTC to 7:02:01 ACL_SINEWAVE_CH noise_line11 "V" 0 SAMP_FREQ 0.5 103 0 0 ACL_SINEWAVE_CH noise_line31 "V" 0 SAMP_FREQ 0.5 203 0 0 ACL_SINEWAVE_CH noise_line81 "V" 0 SAMP_FREQ 0.5 303 0 0 ACL_SINEWAVE_CH noise_line41 "V" 0 SAMP_FREQ 0.5 403 0 0 ACL_SINEWAVE_CH noise_line91 "V" 0 SAMP_FREQ 0.5 503 0 0 ACL_SINEWAVE_CH noise_line51 "V" 0 SAMP_FREQ 0.5 603 0 0 ACL_SINEWAVE_CH noise_line21 "V" 0 SAMP_FREQ 0.5 653 0 0 ACL_SINEWAVE_CH noise_line101 "V" 0 SAMP_FREQ 0.5 703 0 0 ACL_SINEWAVE_CH noise_line61 "V" 0 SAMP_FREQ 0.5 753 0 0 ACL_SINEWAVE_CH noise_line71 "V" 0 SAMP_FREQ 0.5 803 0 0 next we will move 503 Hz to 553 Hz because 503 Hz falls right in the hrec big peak (WI magnet) reason is that we have increased distance from SDB2 ... coil in the SDB1 N-W corner (close to EQB1) axis EW 07:14:52 UTC to 07:46:08 sweep 1800s 5V from 10 to 1000 Hz lines from 07:46:08 to 07:58:00 coil axis NS sweep 1800s 5V from 10 to 1000 Hz from 08:01:48 to 08:32:55 coil axis VERT sweep 1800s 5V from 10 to 1000 Hz from 8:35:52 to 9:06:27 moved to TCS room ENV_TCS_MAG_COIL_CURR_MON -----IMPORTANT NOTE: we inserted the wron calibration: 10000 instead of 10, (!!!) remember to scale by 1000 during analisys NI tower small coil at NI MAG position, we unlocked while positioning the coil !!! r10:19 UTC - ITF locked quiet, good sensitivity 10:28:00 to 10:34 coil axis EW sweep 1800s 5V from 10 to 1000 Hz 10:34:08 to 11:09:28 coil axis NS 11:16:37 to 11:54:07 sweep 1800s 5V from 10 to 1000 Hz coil axis VERT sweep 600s 5V from 8 to 330 Hz 11:59:15 to 12:20:27 unlock at 12:06:30 (earthquake?) when the sweep was around 150Hz (that is enough for us, so we move to WI) WI tower note: severat glitches in DARM maily around 15Hz.... seems not related to us coil axis EW sweep 1800s 5V from 10 to 1000 Hz 13:23:08 13:48:41 (we stop the sweep at about 850Hz to gain time, because after 150Hz we see nothing in Hrec) coil axis NS sweep 8 Hz, 330 Hz, 5V, 600s 13:57:36 to 14:07:57 coil axis VERT sweep 8 Hz, 330 Hz, 5V, 600s 14:09:22 to 14:20:30 BS tower coli axis EW unlock because of Earthquake The shift ends here. we leave the equipment in TCS room and small coil at BS.