DAC output is connected to DAQ BOX ADC channel 9:37 to 9:47 utc dac2adc test (adc= ENV_NEB_MAG_V) Measured TF (ENV_NEB_NOISE / ENV_NEB_MAG_V) has a rotating phase, which might be associated to different filtering --> this could explain (to be chacked) the phase rotation observed last TUESDAY in TF between MAGNETOMETER and ENV_NEB_NOISE 9:53 to 9:58 utc current driving mode - colored noise (0-1000Hz, amplitude 0.1): reached amplifier voltage limit --> TRICK: will have to reduce band of injection but we notice that magnetometers saturate limit for random noise injection is about 100 times above ambient noise (cannot for sure reach 1000 times above ambient noise) colore noise 0-1000 Hz, level 0.1 repeat magnetometers TF measurements (we are now sure that mags are not saturating) ENV_NEB_MAG_N,W are in the refrence location we move ENV_NEB_MAG_V 1) MAG_V is next to chamber, East side, along EW 1327142530 25 Jan 2022 10:41:52 UTC (25 Jan 2022 11:41:52 CET) 1327142832 25 Jan 2022 10:46:54 UTC (25 Jan 2022 11:46:54 CET) reduce level to 0.05 to have more sat margin when we move the magnetometer 2) MAG_V is next to chamber, East side, along NS 1327142985 25 Jan 2022 10:49:27 UTC (25 Jan 2022 11:49:27 CET) 1327143373 25 Jan 2022 10:55:55 UTC (25 Jan 2022 11:55:55 CET) 3) MAG_V is next to chamber, South side, along EW ---> BAD! magnetometer is saturating because of 50Hz 1327143601 25 Jan 2022 10:59:43 UTC (25 Jan 2022 11:59:43 CET) 4) MAG_V is next to chamber, South side, along NS ---> NOT possible to accomodate the magnetometer .... 5) MAG_V is next to chamber, North side, along NS 1327143980 25 Jan 2022 11:06:02 UTC (25 Jan 2022 12:06:02 CET) 1327144326 25 Jan 2022 11:11:48 UTC (25 Jan 2022 12:11:48 CET) 6) MAG_V is next to chamber, North side, along EW 1327144457 25 Jan 2022 11:13:59 UTC (25 Jan 2022 12:13:59 CET) 1327144968 25 Jan 2022 11:22:30 UTC (25 Jan 2022 12:22:30 CET) 7) MAG_V is next to chamber, West side, along NS 1327145434 25 Jan 2022 11:30:16 UTC (25 Jan 2022 12:30:16 CET) 1327145831 25 Jan 2022 11:36:53 UTC (25 Jan 2022 12:36:53 CET) 7) MAG_V is next to chamber, West side, along EW 1327146005 25 Jan 2022 11:39:47 UTC (25 Jan 2022 12:39:47 CET) 1327146515 25 Jan 2022 11:48:17 UTC (25 Jan 2022 12:48:17 CET)