setup ready, we start 1269420364 28 Mar 2020 08:45:46 UTC (28 Mar 2020 09:45:46 CET) colored 500 980 0.002 1269420781 28 Mar 2020 08:52:43 UTC (28 Mar 2020 09:52:43 CET) 0.001 1269421230 28 Mar 2020 09:00:12 UTC (28 Mar 2020 10:00:12 CET) 0.0005 1269421650 28 Mar 2020 09:07:12 UTC (28 Mar 2020 10:07:12 CET) off 1269421993 28 Mar 2020 09:12:55 UTC (28 Mar 2020 10:12:55 CET) colored 25 50 0.002 1269422424 28 Mar 2020 09:20:06 UTC (28 Mar 2020 10:20:06 CET) colored 25 50 0.005 1269422719 28 Mar 2020 09:25:01 UTC (28 Mar 2020 10:25:01 CET) colored 50 20 0.005 1269423014 28 Mar 2020 09:29:56 UTC (28 Mar 2020 10:29:56 CET) colored 50 5 0.005 1269423509 28 Mar 2020 09:38:11 UTC (28 Mar 2020 10:38:11 CET) quit 1269423720 28 Mar 2020 09:42:00 UTC (28 Mar 2020 10:42:00 CET) M.Vardaro on call set to LN3 no SQZ 1269424008 28 Mar 2020 09:46:30 UTC (28 Mar 2020 10:46:30 CET) SHUTTER closed colored 50 20 0.005 1269424226 28 Mar 2020 09:50:08 UTC (28 Mar 2020 10:50:08 CET) colored 500 980 0.005 1269424529 28 Mar 2020 09:55:11 UTC (28 Mar 2020 10:55:11 CET) peaks 50 and 160Hz are no more excited OFF 1269425000 28 Mar 2020 10:03:02 UTC (28 Mar 2020 11:03:02 CET) take some quiet data with shutter OFF 1269425000 28 Mar 2020 10:03:02 UTC (28 Mar 2020 11:03:02 CET) colored 1000 1980 1269426769 28 Mar 2020 10:32:31 UTC (28 Mar 2020 11:32:31 CET) quit 1269427167 28 Mar 2020 10:39:09 UTC (28 Mar 2020 11:39:09 CET) %%%% loudspeaker moved from SAS DET to close to DT cryoptrap colored 500 980 0.001 1269429804 28 Mar 2020 11:23:06 UTC (28 Mar 2020 12:23:06 CET) colored 150 100 0.002 1269430232 28 Mar 2020 11:30:14 UTC (28 Mar 2020 12:30:14 CET) significant acoustic but accelerometers on DT cryoTrap see little, we cannot excite seismically with this acoustic noise % beatings 180 and 180.02 Hz 1269432699 28 Mar 2020 12:11:21 UTC (28 Mar 2020 13:11:21 CET) 1269433451 28 Mar 2020 12:23:53 UTC (28 Mar 2020 13:23:53 CET) %%% shaker at cryoDet colored 100 150 1e-4 1269433477 28 Mar 2020 12:24:19 UTC (28 Mar 2020 13:24:19 CET) 0.003 1269433991 28 Mar 2020 12:32:53 UTC (28 Mar 2020 13:32:53 CET) 0.03 1269434291 28 Mar 2020 12:37:53 UTC (28 Mar 2020 13:37:53 CET) line 180Hz, 0.05 around 12:44 to 13:47 nothing in DARM, nothing in SR accs, but well visible (x10) in variuos DT accs increase amplitude x4 (0.2) 1269434908 28 Mar 2020 12:48:10 UTC (28 Mar 2020 13:48:10 CET) now see a bit in SR acc (west and est flange) and also in DARM shaker 1080Hz and loudspeker in front of DTcryoTrap 180.02 Hz 1269435197 28 Mar 2020 12:52:59 UTC (28 Mar 2020 13:52:59 CET) 1269435594 28 Mar 2020 12:59:36 UTC (28 Mar 2020 13:59:36 CET) TAPPINGS DT cryotrap: (hammer with rubber tip) LT about 13:12 10 hits at SR big flange SOUTH about 13:13 SR big flange East about 13:14 DT CT flange East about 13:15 DT CT bellow about 13:16 DT flange West about 13:18 DT CT flange West re-engaged SQZ: 1269437713 28 Mar 2020 13:34:55 UTC (28 Mar 2020 14:34:55 CET)