shift of 23rd Feb 2019. Stray light investigation on ESQB. S Chua, L Conti 07:45UTC (about): installed 2 accelerometers on ESQ 1234943232UTC reference 1234943518 gentle shaking of table, parallel to long side 1234943868 (07:57:30) gentle shaking of table, parallel to short side 1234943945 (07:58:47) gentle shaking of table, parallel to short side From now on we refer to: X direction: parallel to short side of ESQB Z direction: parallel to long side of ESQB tests with Mini Acc on different places. Each shaking (either tapping or with impulse hammer) lasts about 30 sec MiniAcc on CamFar, MiniAcc axis parallel to X direction: 1234946660 reference 1234946804 shake X direction 1234947081 hammer, vertical 1234947381 hammer, X direction 1234947666 hammer, Z direction MiniAcc on CamNear, MiniAcc axis parallel to Z direction: 1234948001 hammer, Z direction 1234948178 hammer, vertical 1234948313 hammer, X direction 1234948445 tapping along z direction of CamNear base MiniAcc on Faraday Isolator3 - Polarizer mount, MiniAcc axis parallel to X direction 1234949152 hammer, vertical 1234949295 hammer, X direction 1234949398 hammer, Z direction 1234949510 hammer, X direction 1234949627 tapping X direction 1234949823 tapping X direction MiniAcc on Farady Isolator 3 - Magnet mount, MiniAcc axis parallel to vertical direction 1234950355 hammer, vertical 1234950467 hammer, X direction 1234950570 hammer, Z direction MiniAcc on Faraday Isolator3 - Polarizer mount base, MiniAcc axis parallel to X direction 1234951263 hammer, X direction MiniAcc on Steering mirror mount back - MiniAcc axis horizontal, at about 45degree wrt XY (perpendicular to mirror surface) 1234951595 hammer, vertical 1234951765 hammer, X direction 1234951928 hammer, Z direction MiniAcc on CamFar, MiniAcc axis parallel to X direction: 1234952854 hammer, X direction at about 10:55UTC change config file: remove ENV_SQZ_MINI_ACC channel and restore ENV_SQZ_PIPE_ACC_Y 1234955132 tapping pipe flange parallel to X direction 11:10:08 change orientation of pipe flange accelerometer so that axis is parallel to pipe itself, horizontal. 1234955609 reference 1234955694 tapping pipe flange parallel to X direction then we move the accel on the pipe flange back to its original vertical position