This is the logfile for the brute force correlation analysis of target channel Hrec_hoft_20000Hz with 520 auxiliary channels (575 loaded) ['*_SEIS*', '*_ACC*'] from time 12-04 22:23 to time 05 04:38. Total duration of the script: 0 hours, 3 minutes, and 54.45 seconds. Parameters: target: Hrec_hoft_20000Hz gps: 1227997439.0 duration: 22491.0 outfs: 0.04 frequency band(s): [] order: 1 nameSpec_list: ['*_SEIS*', '*_ACC*'] excludedName_spec: ['*_min', '*_Min', '*_Max', '*_max'] The 61 most correlated channels are: Channel name correlation coeff. [%] V1:Sa_BS_F0_Z_ACC_mean -67.457 V1:Sa_SR_F0_ACC_X_mean 66.695 V1:ENV_EIB_SEIS_Y_mean 65.960 V1:ENV_EIB_SEIS_Z_mean -65.365 V1:Sa_SR_F0_ACC_H1_mean 64.804 V1:Sa_IB_F0_ACC_V2_FB_mean 64.759 V1:ENV_SIB2_ACC_Z_rms -64.742 V1:ENV_EIB_SEIS_X_mean 64.483 V1:Sa_IB_F0_ACC_V1_FB_mean 64.164 V1:Sa_BS_F0_ACC_H1_mean 63.713 V1:Sa_WE_F0_ACC_H1_FB_mean 63.504 V1:ENV_CEB_SEIS_V_mean -63.162 V1:Sa_OB_F0_ACC_H3_FB_mean 63.111 V1:ENV_SIB2_ACC_Z_mean 62.518 V1:Sa_MC_F0_ACC_V1_FB_mean -62.215 V1:Sa_MC_F0_ACC_V2_FB_mean 61.783 V1:Sa_SR_F0_ACC_H2_FB_mean 61.358 V1:Sa_SR_BR_ACC_H_FB1_mean 61.358 V1:Sa_BS_F0_TY_ACC_mean -61.298 V1:ENV_SPRB_LINK_ACC_Z_mean 60.563 V1:Sa_NE_F0_ACC_H3_FB_mean -60.557 V1:Sa_PR_F0_ACC_H3_FB_mean -60.147 V1:Sa_NE_F0_ACC_Z_mean -60.048 V1:Sa_WI_F0_ACC_H2_FB_mean 59.988 V1:Sa_SR_BR_ACC_V_mean -59.711 V1:Sa_NE_F0_ACC_H1_FB_mean 59.302 V1:Sa_BS_F0_ACC_H2_mean 59.171 V1:Sa_SR_F0_ACC_TY_mean -59.005 V1:Sa_BS_F0_ACC_H1_FB_mean 58.883 V1:Sa_NI_F0_ACC_H3_FB_mean -58.588 V1:Sa_WE_F0_ACC_H3_FB_mean -58.564 V1:Sa_WI_F0_ACC_H3_FB_mean -58.506 V1:ENV_IB_CT_ACC_X_mean -58.500 V1:Sa_BS_F0_ACC_H2_FB_mean 58.470 V1:ENV_TCS_CO2_NI_SEIS_Y_mean 58.205 V1:Sa_PR_F0_ACC_Z_mean -57.688 V1:Sa_NE_F0_ACC_H2_FB_mean -57.446 V1:ENV_WE_ACC_Z_rms -57.422 V1:Sa_PR_F0_ACC_TY_mean 57.393 V1:ENV_TCS_CO2_WI_SEIS_Y_mean 56.927 V1:Sa_MC_F0_ACC_H2_FB_mean 56.760 V1:Sa_PR_F0_ACC_H2_FB_mean 56.710 V1:Sa_WI_F0_ACC_H1_FB_mean -56.567 V1:Sa_WE_F0_ACC_V1_FB_mean 56.517 V1:Sa_PR_F0_ACC_X_mean 56.304 V1:Sa_SR_F0_ACC_H3_FB_mean -56.303 V1:Sa_SR_BR_ACC_H_FB2_mean -56.303 V1:Sa_WE_F0_ACC_V2_FB_mean 56.013 V1:Sa_PR_F0_ACC_V2_FB_mean -55.918 V1:Sa_NE_F0_ACC_V2_FB_mean 55.880 V1:Sa_NE_F0_ACC_V1_FB_mean 55.653 V1:Sa_MC_F0_ACC_H3_FB_mean 55.542 V1:Sa_IB_F0_ACC_H3_FB_mean -55.441 V1:Sa_NI_F0_ACC_H2_FB_mean 55.379 V1:Sa_PR_F0_ACC_H2_mean 55.302 V1:Sa_PR_F0_ACC_H1_FB_mean 55.253 V1:Sa_WE_F0_ACC_H2_FB_mean 55.146 V1:Sa_SR_F0_ACC_V1_FB_mean -55.073 V1:Sa_SR_BR_ACC_V_FB_mean 55.053 V1:Sa_SR_F0_ACC_H1_FB_mean 55.053