quieto 1225622466 Nov07,18-10:41:06 UTC (Nov07,18-11:41:06 CET) 0.884V 15Hz, DR 1225622616 Nov07,18-10:43:36 UTC (Nov07,18-11:43:36 CET) DARM vede 15 1E-5 e 30 1E-7 0.387V 15Hz, DR (onda visibilmente distorta) 1225622813 Nov07,18-10:46:53 UTC (Nov07,18-11:46:53 CET) 15 riduce di 2, 30 riduce di 5 0.871V 15Hz, DR 1225623061 Nov07,18-10:51:01 UTC (Nov07,18-11:51:01 CET) OFF 1225623172 Nov07,18-10:52:52 UTC (Nov07,18-11:52:52 CET) stessa linea su UR 1225623242 Nov07,18-10:54:02 UTC (Nov07,18-11:54:02 CET) 15Hz 7E-5, 30 1E-7 (tutte le armoniche dispari sono piu' alte) OFF 1225623471 Nov07,18-10:57:51 UTC (Nov07,18-11:57:51 CET) attacco linea su DL 1225623559 Nov07,18-10:59:19 UTC (Nov07,18-11:59:19 CET) 15 7E-7, 30 1E-7 OFF 1225623799 Nov07,18-11:03:19 UTC (Nov07,18-12:03:19 CET) attacco linea su UL 1225623811 Nov07,18-11:03:31 UTC (Nov07,18-12:03:31 CET) 15 4E-6 30 1E-7 OFF (no GPS timing) ---- test of increasing the Amplitude of the excitation line ------ linea su DL, stessa ampiezza 1225624030 Nov07,18-11:07:10 UTC (Nov07,18-12:07:10 CET) 15 8E-7, 30 1E-7 raddoppio a 2V 1225624151 Nov07,18-11:09:11 UTC (Nov07,18-12:09:11 CET) 15 1.7E-6, 30 4.5E-7 raddoppio, a 4V 1225624328 Nov07,18-11:12:08 UTC (Nov07,18-12:12:08 CET) 15 3.5E-6, 30 1.7E-6 OFF (no GPS timing) ------------------- Paolo displaces the cage, ma dalla parte sbagliata e tocca, unlock cage NE spostata dalla parte opposta relock (linea sempre accesa a 4V su DL ...) 1225631584 Nov07,18-13:13:04 UTC (Nov07,18-14:13:04 CET) anche 600s prima %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% %%% NOTA: "1V" means 0.877 V %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% ------ AFTERNOON: NE, cage still displaced OFF DL 1225631606 Nov07,18-13:13:26 UTC (Nov07,18-14:13:26 CET) ************************ 15Hz 1V a DR 1225631639 Nov07,18-13:13:59 UTC (Nov07,18-14:13:59 CET) 15 1E-5, 30 8E-8 15Hz 1V a UR 1225632568 Nov07,18-13:29:28 UTC (Nov07,18-14:29:28 CET) 15 2E-5, 30 7E-8 Unlock relock (again 15Hz 1V a UR) 1225634751 Nov07,18-14:05:51 UTC (Nov07,18-15:05:51 CET) 15 2.4E-5, 30 6.6E-8 15Hz 1V a DL 1225634865 Nov07,18-14:07:45 UTC (Nov07,18-15:07:45 CET) 15 1E-8, 30 7E-8 15Hz 1V a UL 1225635095 Nov07,18-14:11:35 UTC (Nov07,18-15:11:35 CET) 15Hz, 1V 15 1.7E-6, 30 5.4E-8 OFF 1225635346 Nov07,18-14:15:46 UTC (Nov07,18-15:15:46 CET) %%%%%% test of changing frequency (on UR) (15) 27Hz, 45Hz 15Hz 1V su UR 1225635390 Nov07,18-14:16:30 UTC (Nov07,18-15:16:30 CET) 15 2E-5, 30 7E-8 27Hz, 1V su UR 1225635718 Nov07,18-14:21:58 UTC (Nov07,18-15:21:58 CET) 27 2.4E-5, 54 2.7E-8 45Hz, 1V su UR 1225635865 Nov07,18-14:24:25 UTC (Nov07,18-15:24:25 CET) but unlocked immediately reconnect all coils NE ------------------------------ %%%%%% WE gps QUIET: 1225637892 Nov07,18-14:58:12 UTC (Nov07,18-15:58:12 CET) DR, 15Hz, 1V 1225639862 Nov07,18-15:31:02 UTC (Nov07,18-16:31:02 CET) 15 3E-6, 30 7E-8 DL, 15Hz, 1V 1225640033 Nov07,18-15:33:53 UTC (Nov07,18-16:33:53 CET) 15 6E-5, 30 7E-8 noise floor 20-40Hz is lower....!! UR, 15Hz, 1V 1225640446 Nov07,18-15:40:46 UTC (Nov07,18-16:40:46 CET) 15 3E-5., 30 7E-8 UL, 15Hz, 1V 1225640859 Nov07,18-15:47:39 UTC (Nov07,18-16:47:39 CET) 15 2.4E-5, 30 7E-8 back to 4 coils connected 1225640973 Nov07,18-15:49:33 UTC (Nov07,18-16:49:33 CET) DL floating 1225641075 Nov07,18-15:51:15 UTC (Nov07,18-16:51:15 CET) noise lower 20-40Hz, but bump around 50Hz! short-circuit DL coil, floating 1225641183 Nov07,18-15:53:03 UTC (Nov07,18-16:53:03 CET) unlocked 1225643959 Nov07,18-16:39:19 UTC (Nov07,18-17:39:19 CET) we leave all WE coils disconnected