as of last today: TX == length, TY == pitch all damped using length ++++++++++++++ NE_VIOLIN1 445.84 Hz 100k gain, flt1 @ 18:58 UTC NE_VIOLIN2 446.27 Hz 10k gain, flt1 @ 17:51 UTC NE_VIOLIN3 448.90 Hz 100k gain, flt1 @ 17:44 UTC NE_VIOLIN4 449.30 Hz -1k gain, flt1 @ 20:30 UTC NE_VIOLIN5 449.33 Hz NE_VIOLIN6 449.71 Hz 20k gain, flt1 @ 20:25 UTC NE_VIOLIN7 452.10 Hz 10k gain, flt1 @ 20:55 UTC NE_VIOLIN8 452.50 Hz 10k gain, flt1 @ 20:58 UTC WE_VIOLIN1 447.34 Hz 10k gain, flt1 @ 20:10 UTC WE_VIOLIN2 447.81 Hz 10k gain, flt1 @ 20:12 UTC WE_VIOLIN3 449.36 Hz WE_VIOLIN4 449.72 Hz 30k gain, flt1 @ 22:00 UTC WE_VIOLIN5 451.78 Hz 10k gain, flt1 @ 19:47 UTC WE_VIOLIN6 452.30 Hz 10k gain, flt1 @ 19:35 UTC WE_VIOLIN7 452.81 Hz 100k gain, flt1 @ 19:38 UTC WE_VIOLIN8 453.14 Hz 10k gain, flt1 @ 19:42 UTC NI_VIOLIN1 443.67 Hz 10k gain, flt1 @ 21:38 UTC NI_VIOLIN2 444.06 Hz 5k gain, flt1 @ 19:27 UTC NI_VIOLIN3 445.15 Hz 100k gain, flt1 @ 20:24 UTC NI_VIOLIN4 445.54 Hz 5k gain, flt1 @ 19:34 UTC NI_VIOLIN5 449.23 Hz NI_VIOLIN6 449.61 Hz NI_VIOLIN7 450.18 Hz 20k gain, flt1 @ 19:43 UTC NI_VIOLIN8 450.56 Hz 10k gain, flt1 @ 19:45 UTC WI_VIOLIN1 444.73 Hz 30k gain, flt1 @ 18:14 UTC WI_VIOLIN2 445.11 Hz 5k gain, flt1 @ 17:58 UTC WI_VIOLIN3 446.89 Hz 10k gain, flt1 @ 19:02 UTC WI_VIOLIN4 447.29 Hz 10k gain, flt1 @ 19:06 UTC WI_VIOLIN5 449.15 Hz 50k gain, flt1 @ 17:39 UTC WI_VIOLIN6 449.56 Hz (didn't damp with filter1,2) WI_VIOLIN7 453.36 Hz 10k gain, flt1 @ 16:20 UTC WI_VIOLIN8 453.78 Hz 10k gain, flt1 @ 15:55 UTC