// Family of lines moving in frequency seen in LSC_DARM // By inspection seem to be correlated to temperature in CEB around f7 // d/o = direct/opposite i.e. image/mirror image or +/- // f1 = frequency at beginning of ER11/a (gps time = 1181635218) // f2 = frequency at end of ER_11/b (gps time = 1182499218) // note that through ER11 the f1 = 83.3Hz line seems to best represent the family d/o f1 f2 _____________________ d 39.5 39.3 d 41.5 41.4 d 42.9 42.8 d 74.3 74.1 d 77.6 77.5 d 83.3 83.1 d 84.3 84.2 d 124.3 124.1 d 125.5 125.3 d 132.1 131.9 d 211 210.7 d 216.3 216 d 220.8 220.6 d 286.3 286.2 d 287.4 287.3 d 295.2 295 d 321.5 321.4 d 370.6 370.5 o 89.9 90 o 95 95.1 o 104.8 105 o 107.1 107.2 o 109.9 110 o 111.9 112 o 114.5 114.6 o 129.9 130