The first lock at 16h00-UTC was luky as the OMC lock noise disappeared just after the OMC lock with B1_PD3_Audio (plot) but not the others ones (ie 21h50m-UTC one)
The first lock at 16h00-UTC was luky as the OMC lock noise disappeared just after the OMC lock with B1_PD3_Audio (plot) but not the others ones (ie 21h50m-UTC one)
Here we report a few more observations concerning the excess noise causing problems to reach DC readout.
The excess noise is visible on the audio channels of several photodiodes (Fig.1 and Fig.2): B1s, B1sP and B1_PD3 (which are on the same service mezzanine) as well as on the B1p_PD1 audio channel (however in this later case, only lines are present, while for B1s and B1_PD3 there is a clear impact on the noise floor).
As reported already by Diego, an extra noise is also present on the SDB1_LC_TX_err and SDB1_LC_TY_err signals at the same time as the noise is present on the photodiodes. This SDB1_LC_TX/TY_err signals are constructed from the SDB1 B5 QD2 H and V signals, which also see the extra noise. This observation concerning the SDB1 local control was already true yesterday (Fig.3)
Both the spectrum of the B1_PD1 audio channel, and those of SDB1_B5_QD2_H/V signals are clean when we are in CARM_NULL_1F (Fig.4).
The extra lines on B1p_PD1 and the extra noise on the B5 QD2 signals show up as soon as the OMC shutter is open (Fig.5). The lines showing up on B1_PD1 are at the same frequency as the lines seen on B1s (Fig.6), although the B1s noise floor changes when the lock of the OMC is acquired.
The following plots shows a 300s FFTTime of the SDB2_B1p_PD1_Audio, SDB2_B1_PD3_Audio and the SDB2_B1s_PD1_Audio channels during the OMC lock acquisition where the purple rectangle highlights the periods with the presence of unexpected lines
Upon reaching the site, I found the ITF in LOW_NOISE_3_SQZ and in Science Mode. The ITF unlocked at 15:03 UTC due to an earthquake (M 6.3 - 17 km WSW of Uwajima, Japan, 14:14 UTC), preventing the lock of the infrared cavities.
From 15:40 UTC the influence of the shaking decreased enough and it was possible to relock.
ITF back in LOW_NOISE_3_SQZ at 16:16 UTC and the planned ISC/INJ activity (see report #64007) started; work concluded at 19:13 UTC.
The ITF unlocked at 19:24 UTC, followed by various unlocks at different steps of the locking acquisition (ACQUIRE_LOW_NOISE_2, LOCKING_CARM_NULL_1F).
Relock in progress.
No DMS alerts received were received during the shift.
Guard tour (UTC)
17:01 - 17:42
19:01 - 19:28
After the earthquake in Japan, we relocked at the first trial and after we arrived LN3_SQZ we started to tune the noise injections for the PSTAB loop (both at LF and HF). After the amplitude of the noise was tuned, we added the corresponding functions into the "injection_SSFS.py" script.
We then proceeded to repeat by hand the two last injections of the SSFS loop, that last shift made the ITF unlock. We decreased slightly their amplitude, while checking that the coherence with Hrec was still high. Now the script launches: CLEAN SSFS_UGF PSTAB_LF PSTAB_HF and then the 4 other SSFS injections at lower frequencies (down to 100 Hz). The operator launched the script and it worked without any problem. Figure 1 shows the injection corresponding to SSFS_UGF, and I think the current UGF is safe enough (I wouldn't push much higher, to ensure robustness, unless the noise injections suggest that it is limiting).
At this point we passed to the DIFFp topic. We started by opening the DIFFp_TX servo loop (which zeros the offset!), and then we started to put back the offset. However this didn't zeroed the new signals and so we continued to increase the offset. During this scan we tried to tune the phase, slightly, even if it was already quite good. Then we repeated the same operation with the TY loop. Figure 2 shows the two scans that we did. For the TY the phases were not clear so we left the deafult ones.
The phases we put are:DIFFp_TX_DCP_HF_mag_B1_phi0 = 0.5; DIFFp_TX_DCP_mag_B1_phi0 =0.5
Today at about 15:30UTC, during the recovery operations of the interferometer, we reactivated the pumping station '200m' on the 'squeezing' vacuum line
Today we had another event of the noise suddenly disappearing, and this happened before the lock of the OMC, at 16:02:59 UTC (Figure 1); the lock of OMC and DC Readout went through fine (Figure 2).
The error signal SDB1_LC_TY_err also shows a similar behaviour to B1_PD3 regarding the 1722 Hz line, but a much more broadband effect as well (Figure 1 and spectra in Figures 3 and 4).
For debugging purposes, the channels Audio and DC related to the B1_PD3 and B1s_PD1 photodiodes acquired at 100KHz are now stored with the "_FS" suffix and available in the RAW_FULL stream .
Below the list of the channels, acquired by the SDB2_DBOX_RightDown - SDB2_MezzPD2 mezzanines at 100KHz and stored with the "_FS" suffix:
V1:SDB2_B1_PD3_Audio_raw_FS nData= 100000 min= -6.11e+03 mean=-4.89e+03 max=-3.56e+03 rate= 100000Hz
V1:SDB2_B1_PD3_DC_raw_FS nData= 100000 min= -3.55e+03 mean=-3.31e+03 max=-3.07e+03 rate= 100000Hz
V1:SDB2_B1sP_PD1_Audio_raw_FS nData= 100000 min= -2.69e+05 mean=-2.67e+05 max=-2.65e+05 rate= 100000Hz
V1:SDB2_B1sP_PD1_DC_raw_FS nData= 100000 min= -3.62e+03 mean=-3.38e+03 max=-3.14e+03 rate= 100000Hz
V1:SDB2_B1s_PD1_Audio_raw_FS nData= 100000 min= 6.12e+04 mean= 6.2e+04 max= 6.28e+04 rate= 100000Hz
V1:SDB2_B1s_PD1_DC_raw_FS nData= 100000 min= 1.54e+04 mean= 1.57e+04 max= 1.6e+04 rate= 100000Hz
Are the transients corresponding to time that where outside of science mode during the same hour due to adjustments?
Yes for the first two, not completely for the third transient -- see attached plot. Are there some guidances to assess when switching back to science after one such adjustment?
Are the transients corresponding to time that where outside of science mode during the same hour due to adjustments? See figure 1.
These should be nice scattered light injections from moving SWEB https://logbook.virgo-gw.eu/virgo/?r=63997. It would be nice if someone could confirm it by looking at the same spectrogram for DET_B8_DC, and also see if the frequency corresponds to the speed of the bench in the Z direction (along the beam).
Continuing the investigation of the spectral noise on the first week of O4b data, we found an interesting structure of "wandering sidebands" around the 50 Hz line. (S
Figure 1 shows the spectrogram in the region 42-58 Hz around the frequency of the electric mains. Two pairs of wandering sidebands are visible at 44 (Figure 2) and 56 Hz, and at 46.7 (Figure 3) and 53.3 Hz (Figure 5).
The oscillations in frequency, especially those of the 44 and 56 Hz lines, are the same as those of the 50 Hz line (Figure 4) but enlarged by many (~20) times: ~0.50 Hz vs ~0.025 Hz
Additionally, taking advantage of a couple of glitches present in the analyzed data period (the vertical lines), we notice that the 44 and 47.3 Hz lines are synchronous with the 50 Hz line. Also, the 53.3 Hz line seems to have the same phase, while the one at 56 Hz is flipped vertically: Figure 5.
The search for bilinear couplings with MONET highlighted that the 46.7 and 53.3 Hz sidebands are produced by the modulation of the mains line (ENV_CEB_UPS_VOLT_R_2000Hz) and the ASC_DIFFp_T{X,Y} angular control channels: Figure 6 and text file.
A barely negligible coherence has been found for the lines at 44 and 56 Hz; just a 0.1 with SDB1_LC_TX at 56 Hz: Figure 7. This could be a consequence of the large variations in the frequency of the line, which dilute the cohere over multiple frequency bins and, averaged gets small.
Of course, the same structure is present around the other harmonics of the 50 Hz line.
Upon arrival I found ITF in Science Mode (LN3_SQZ).
At ~ 08:50 UTC the vertical position loop of SWEB opened. I set Adjusting Mode and closed it but it opened again after few minutes. I tried to act on MotSwitch but it was not working. I contacted SBE OnCall but the issue was related to the old version of MotSwitch VPM config file. I restarted the MotSwitch process and act on MotSwitch Olwin tool to recover the vertical position of the bench. I made a check for all SBE MotSwitch processes are running with the v4r4 version.
Science Mode set again at 09:45 UTC.
No DMS Events Monitor to report
Oncall eventsDET
(16-04-2024 19:30 - 23:15) From remote
Status: On-going
Description: unlock at DC_READOUT step
SBE
(17-04-2024 10:00 - 17-04-2024 10:30) Operator on site with expert from remote
Status: Ended
Description: SWEB vertical loop open.
Problem fixed thanks to Carbognani who investigated on MotSwitch VPM config file process.
This morning, three transient noises, lasting several tens of seconds and limited to the 10-100 Hz frequency band, occured around 9h08 UTC, 9h38 UTC, 9h45 UTC.
Plot1 shows them in the spectrograms of LSC_DARM and Hrec_hoft_raw (on the same plot we can see also two 25' glitches).
Plot2 is a zoom on the third of those transient noises.
Are the transients corresponding to time that where outside of science mode during the same hour due to adjustments? See figure 1.
These should be nice scattered light injections from moving SWEB https://logbook.virgo-gw.eu/virgo/?r=63997. It would be nice if someone could confirm it by looking at the same spectrogram for DET_B8_DC, and also see if the frequency corresponds to the speed of the bench in the Z direction (along the beam).
Are the transients corresponding to time that where outside of science mode during the same hour due to adjustments?
Yes for the first two, not completely for the third transient -- see attached plot. Are there some guidances to assess when switching back to science after one such adjustment?
In the framework of the ongoing investigations for the study of spectral noise, I repeated the analysis done for the mini-Engineering Run, with the estimate of a high-resolution sensitivity curve and the rough identification of the main spectral lines, as described in this logbook entry: #63221. The result can be used as a reference and for comparison with the output of more refined tools, such as NoEMi.
As a remark, the frequency resolution of 1mHz is obtained with 1000 second-long FFTs. This duration is constrained by the 25-minute glitches; estimating the ASD with median averages is robust to these glitches if most of the FFTs are not affected by their presence. This requires using FFTs shorter than 25 minutes (1500 sec).
The data segment to be analyzed was the one with the longest duration in Science mode, weighted by the lowest coefficient of variation. The choice fell on the segment: 2024-04-13 01:53:18 to 2024-04-13 18:30:04 (59806.0 sec).
I attach to this entry the pdf with the details of the various frequency regions of the spectrum and the CSV with the identified lines. I plan to repeat this analysis for the next weeks, and attach the results in this git issue and its sub-tasks, for reference.
I'm adding also the following images:
Figure 1: high-resolution sensitivity curve with red lines corresponding to the identified spectral lines. Refer to the PDF file for the details.
Figure 2: detail of the 970-995 Hz region, showing a comb of lines spaced about ~2.83 Hz (0.35 sec).
Figure 3: spectrogram of the 955-1005 Hz region, showing the wandering line already documented in these logbook entries: #60093, #61873.
As of today online BruCo should run daily on Science segments -- until now it was running on locked segments. The segments processed by online BruCo should thus be more stable, while they may also be more numerous -- as one can leave Science for a short while w/o loosing the lock. I'll monitor the potential increase of running time in the coming days. Another improvement is that loud glitches (defined as having an Omicron SNR greater than 50) should now be excluded from the segments processed by online Bruco. Online BruCo is configured to run of segments lasting at least 15 minutes: thus, the 25-minute glitches should be safely removed w/o rejecting Science segments. I'll keep an eye on that as well to make sure the loud glitch removal doesn't kill all the online BruCo input segments.
After the modification of PR ACC H modulation frequency, we had 3 fast glitches - the usual rate observed recently - but no one triggered a trip. This is a good news: it seems that the problem has been fixed. To be noticed that the trips disappeared also from the vertical loop, but PR ACC V modulation frequency was not touched.
ITF found in Commissioning mode for: Change of logic for the LOW_NOISE_1 and LOW_NOISE_2 to bypass LowNoise1 actuation stage; activity concluded at 21:00 UTC
In parallel, Romain and Victor were investigating the excess noise on B1_PD3 that was preventing to lock the OMC thus at 21:15 I set Troubleshooting.
At 23:14 UTC we could lock the OMC but we unlocked during the transition to LN2; unfortunately the excess noise came back after the previous unlock.
Diego worked up to 1:00 UTC trying to understand the problem but we kept unlocking during the lock of the OMC; for the next lock acquisition we decided to wait more time in CARM_NULL_1F and try to perform the trick of the SR but unfortunately the ITF unlocked again.
The lock of the OMC kept failing for the next two hours; then at, around 3:00 UTC, the OMC locked again but the ITF unlocked LN2.
At the next attempt the ITF reachedn LN3_SQZ thus at 4:01 UTC I could set Science mode.
Guard tous (time in UTC)
21:00-21:30; 23:00 -23:30; 1:00-1:30; 3:!0-3:40
Oncall eventsDET
(16-04-2024 19:30 - 23:15) From remote
Status: On-going
Description: unlock at DC_READOUT step
Unfortunately the excess noise came back already at the following lock acquisition, with the same features (Fig. 1, purple, red and blue are noise, no noise, and noise again respectively).
Looking at the B1_PD3_DC spectrum we can see many big lines (and sidebands) (Fig. 2); the most offending in terms of SNR is the one at ~6885 Hz (Fig. 3), but what is striking at a first glance is that all of them are separated by ~1722 Hz, although the lowest one is not the strongest one, so maybe also some aliasing is involved.
As part of the today's commissioning work on the MIR/MAR reallocation between IMs and EMs, the logic of the two LowNoise configurations has been changed: a new parameter, bypass_ln1, is defined as boolean in the [ITF_LOCK] section of the ITF_LOCK.ini file.
When this parameter is set to True, during the LOW_NOISE_1 transition we will keep using the Input Mirrors to actuate. And obviously nothing will be done on the relays. Also, we will prepare the End Mirrors to use directly their LowNoise configuration, i.e. LowNoise2.
During the LOW_NOISE_2 transition, we will jump directly from HighPower to LowNoise2. The only caveat here is whether we can survive acting on the IM relays when already in LOW_NOISE_2 (we usually do that in LOW_NOISE_1). The other caveat is that with the very high useism we have now, the standard lock acquisition would probably not work anyway given our current problems.
More information on the changes at the level of the actuators are reported in the aforementioned entry.
After the (unfortunately temporary) fix of DC Readout we managed to test the new logic described here; unfortunately, as feared, acting on the IM relays while already in LowNoise2 made the ITF to unlock, at least in the single test that we could make (unlock at 23:19:51 UTC); this is apparently strange, as this kind of action was done in the past for the charge measurements, but it could be that the full switch on both IMs at the same time is too much. We could think of acting on them in series on one IM at a time, to be studied.
After this test, and seeing that the useism is going down (still far from being low, though), we reverted to the standard strategy, which needs a check anyway since it is embedded in the same new logic. Unfortunately we started to have issues again in the OMC/DC Readout phase, so this is still ongoing at the time of writing.
While investigating the problem with the lock in DC readout, we noticed that the B1_PD3 audio channel was much noisier than usual for all frequencies above 100 Hz, and also the OMC PZT correction spectrum was much noisier. We also noticed that the power on the carrier TEM00 was lower than expected for a DARM offset of -0.20.
Then, without doing anything, we observed a sudden transient at 21h40 utc that made this excess noise disappear and the B1_PD3_DC power getting back to normal.
The attached figures are comparing the B1_PD3 and OMC corrections spectrum with the excess noise (in purple) and the situation right after the noise disappeared (blue).
It was then possible to relock in DC readout while keeping the same parameters as usual for the transition to DC readout.
This strange excess noise will be further investigated tomorrow.
Unfortunately the excess noise came back already at the following lock acquisition, with the same features (Fig. 1, purple, red and blue are noise, no noise, and noise again respectively).
Looking at the B1_PD3_DC spectrum we can see many big lines (and sidebands) (Fig. 2); the most offending in terms of SNR is the one at ~6885 Hz (Fig. 3), but what is striking at a first glance is that all of them are separated by ~1722 Hz, although the lowest one is not the strongest one, so maybe also some aliasing is involved.
For debugging purposes, the channels Audio and DC related to the B1_PD3 and B1s_PD1 photodiodes acquired at 100KHz are now stored with the "_FS" suffix and available in the RAW_FULL stream .
Below the list of the channels, acquired by the SDB2_DBOX_RightDown - SDB2_MezzPD2 mezzanines at 100KHz and stored with the "_FS" suffix:
V1:SDB2_B1_PD3_Audio_raw_FS nData= 100000 min= -6.11e+03 mean=-4.89e+03 max=-3.56e+03 rate= 100000Hz
V1:SDB2_B1_PD3_DC_raw_FS nData= 100000 min= -3.55e+03 mean=-3.31e+03 max=-3.07e+03 rate= 100000Hz
V1:SDB2_B1sP_PD1_Audio_raw_FS nData= 100000 min= -2.69e+05 mean=-2.67e+05 max=-2.65e+05 rate= 100000Hz
V1:SDB2_B1sP_PD1_DC_raw_FS nData= 100000 min= -3.62e+03 mean=-3.38e+03 max=-3.14e+03 rate= 100000Hz
V1:SDB2_B1s_PD1_Audio_raw_FS nData= 100000 min= 6.12e+04 mean= 6.2e+04 max= 6.28e+04 rate= 100000Hz
V1:SDB2_B1s_PD1_DC_raw_FS nData= 100000 min= 1.54e+04 mean= 1.57e+04 max= 1.6e+04 rate= 100000Hz
Today we had another event of the noise suddenly disappearing, and this happened before the lock of the OMC, at 16:02:59 UTC (Figure 1); the lock of OMC and DC Readout went through fine (Figure 2).
The error signal SDB1_LC_TY_err also shows a similar behaviour to B1_PD3 regarding the 1722 Hz line, but a much more broadband effect as well (Figure 1 and spectra in Figures 3 and 4).
The following plots shows a 300s FFTTime of the SDB2_B1p_PD1_Audio, SDB2_B1_PD3_Audio and the SDB2_B1s_PD1_Audio channels during the OMC lock acquisition where the purple rectangle highlights the periods with the presence of unexpected lines
Here we report a few more observations concerning the excess noise causing problems to reach DC readout.
The excess noise is visible on the audio channels of several photodiodes (Fig.1 and Fig.2): B1s, B1sP and B1_PD3 (which are on the same service mezzanine) as well as on the B1p_PD1 audio channel (however in this later case, only lines are present, while for B1s and B1_PD3 there is a clear impact on the noise floor).
As reported already by Diego, an extra noise is also present on the SDB1_LC_TX_err and SDB1_LC_TY_err signals at the same time as the noise is present on the photodiodes. This SDB1_LC_TX/TY_err signals are constructed from the SDB1 B5 QD2 H and V signals, which also see the extra noise. This observation concerning the SDB1 local control was already true yesterday (Fig.3)
Both the spectrum of the B1_PD1 audio channel, and those of SDB1_B5_QD2_H/V signals are clean when we are in CARM_NULL_1F (Fig.4).
The extra lines on B1p_PD1 and the extra noise on the B5 QD2 signals show up as soon as the OMC shutter is open (Fig.5). The lines showing up on B1_PD1 are at the same frequency as the lines seen on B1s (Fig.6), although the B1s noise floor changes when the lock of the OMC is acquired.
The first lock at 16h00-UTC was luky as the OMC lock noise disappeared just after the OMC lock with B1_PD3_Audio (plot) but not the others ones (ie 21h50m-UTC one)
This afternoon shift was dedicated to commissioning: MIR/MAR reallocation, the work was carried out by Diego, Manuel and Paolo; during the afternoon we collected several fails in LOCKING_DC_READOUT state while opening the B1 PD1 and PD2 photodiode shutters, we succeeded to pass this state only two times, in the evening we called Victor (DET on-call) to investigate this issue, investigation on locking troubles in progress...
Sub-system reportsSBE
at 17:49UTC the SNEB position loop was opened by the guardian, controls properly closed.
DET
(16-04-2024 19:30 - ) From remote
Status: On-going
Description: unlock at DC_READOUT step
Last night a big worsening of the weather condition arrived (fig 1) and produced the feared increase of correction on NE / WE mirrors, touching some time 10 V (fig 2). There was no need to wait for the strong wind of today, because the microseismic region, between 0.5 and 1 Hz, was enough to create problems (fig. 3).
Today we had in mind to test a filter for the windy condition, so we proceeded like that. In fig 4 we see that a result was achieved for the low frequency (200 mHz and < 100 mHz): a worsening of the sismic signal (first plot) did not produce an equivalent worsening of the correction. Unfortunately, we were again close to the instability at 1.8 Hz.
The next planned test was to move the marionette correction from ITMs to ETMs and see the effect on the 1,8 Hz instability. We started moving the north arm and the 1.8 Hz became quickly unstable, unlocking the ITF (fig 5, fig 6). Probably the right way to do the test would have been to move both the arms at the same time, but we had no opportunity to try.
We developed a new filter, which is supposed to gain less at low frequency, improve a bit between 0.5 and 1 Hz, and behave at 1.8 Hz about like the one which worked well the past days. We are waiting for a successful lock to know if it works.
In order to achieve LN2 in the current weather condition, a change of transition strategy was required, because normally we need to pass through a locking done by only a pair of mirror coils instead of all the four. If the mirror correction often exceeds 5 V like now, very likely it will saturate when 2 coils are used with the double gain. It happened like that the time we tried the normal transition. The new strategy consists in skipping the transition to LN1: setting directly the LN2 state for ETMs actuation and moving form ITMs to ETMs in this condition, we can continue using the four coils. The strategy worked, but it was not totally tested: the final step of disabling the ITMs high power state through the relays was not tested yet. The usual glitch caused by this action could be too large for LN2. The glitch could be eventually reduced because it is due to a DC value present on the high power actuation, which can be better subtracted digitally.
So far we had just one fast gitch on the three PR ACC, not too different from the usual ones, but it was not followed by any trip. Let's wait for the next.