Reports of 58442
Virgo Runs (O4b)
Sposito - 9:14 Saturday 20 April 2024 (64038) Print this report
Operator Report - Morning shift
Images attached to this report
AdV-DAQ (Data collection)
masserot - 8:57 Saturday 20 April 2024 (64039) Print this report
DAQ - TolmFrameBuilder unable to send theirs frames

Around  2024-04-20-06h06m28 most of the TolmFrameBuidler servers were unable to transmit theirs frames : it s probably the cause of the ITF unlock

Below the message reported by some TolmFRameBuilder servers

  • ISC_Fb
    • 2024-04-20-06h06m28-UTC>ERROR..-frame 1397628405 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h06m29-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397628407
    • 2024-04-20-06h16m30-UTC>ERROR..-frame 1397629007 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h16m31-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397629009
  • SWEB_Fb
    • 2024-04-20-06h06m28-UTC>ERROR..-frame 1397628405 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h06m29-UTC>INFO...-Memory Used increase, cur. 756764.00(KB), inc. 40.00(KB)
    • 2024-04-20-06h06m30-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397628408
    • 2024-04-20-06h16m30-UTC>ERROR..-frame 1397629007 not send to FbmFFE: sending queue is full
  • SSFS_Fb
    • 2024-04-20-06h06m28-UTC>ERROR..-frame 1397628405 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h06m29-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397628407
    • 2024-04-20-06h16m30-UTC>ERROR..-frame 1397629007 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h16m31-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397629008
  • SUSP_Fb
    • 2024-04-20-06h06m28-UTC>ERROR..-frame 1397628405 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h06m31-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397628409
    • 2024-04-20-06h16m30-UTC>ERROR..-frame 1397629007 not send to FbmFFE: sending queue is full
    • 2024-04-20-06h16m33-UTC>INFO...-output queue to FbmFFE has been flushed; Sending frame 1397629011

The IT departement has been informed to check for a possible network switch issue

Virgo Runs (O4b)
amagazzu - 7:38 Saturday 20 April 2024 (64037) Print this report
Operator Report - Night shift

Upon reaching the site, I found the ITF locked in LOW_NOISE_3 and in Science Mode. It kept the lock for the whole shift.

Guard Tour (UTC):

21:06 - 21:36
22:55 - 23:25
1:33 - 2:02
3:50 - 4:20

Sub-system reports

DAQ
The process ELE_QGBT was not working correctly, it was reported as not working on DMS and in Orange state on VPM. At 1:05 UTC I restarted the process to solve the issue.

Images attached to this report
Vacuum (Cryo Trap)
Vacuum - 1:42 Saturday 20 April 2024 (64036) Print this report
NE cryotrap refilling regulating device

Today at about 14:30 UTC we accessed the NE building to inspect and lubricate the regulator of the pressurized air driving the cryogenic valve #01, that showed signs of malfunctioning. The intervention was concluded within about 10 min  (see also operator's entry). This device will be replaced with a new one next Tuesday .

Virgo Runs (O4b)
menzione - 22:56 Friday 19 April 2024 (64030) Print this report
Operator Report - Afternoon shift

Upon arrival I found ITF stable in Science Mode (LN3_SQZ).
At 13:29 and at 13:33 UTC the SQZ unlocked, relocked at first attempt in both occasions (Science Mode set) but at third failure I contacted SQZ OnCall who checked on it. (Science Mode with ITF in LN3). The issue was related to the humidity level in Det Lab.

DET
13:39 UTC - DetMoni VPM process restarted under request of Gouaty.

At 14:24 UTC I set ADJUSTING in order to allow:
- ACS experts to fix the problem on DET Humidity. Activity concluded at 14:40 UTC. The steam producer was blocked. Soldani pointed out to me that the ENV DMS flag (ENV..SQZ_BOARD_HU) values are not "aligned" with the INF DMS flag (HVAC..DET_HU_IN).
- VAC experts to go at NE to check a CryoTrap valve. Activity concluded at 14:45 UTC.
- ALS Gosselin to reboot green ALS Laser but unfortunately the optic amplifier is not responding anymore. A replacement is planned for tomorrow morning -> AT NEXT UNLOCK WE ARE NOT ABLE TO RELOCK !

15:21 UTC - ITF again in Science Mode

CAL
In order to avoid the risk of ITF unlock, Was asked me to perform "only" 10 times the CALIBRATED_DF_DAILY.
19:00 UTC - ITF set in LN3 (CALIBRATION MODE) Also L1 and H1 DOWN.
- Calibrations started at 19:01 and concluded at 20:54 UTC
LN3_SQZ / Science Mode at 20:55 UTC.

 

Oncall events

SQZ
(19-04-2024 14:00 - 19-04-2024 14:25) From remote
Status: concluded
Description: The result of check of the SQZ failure was due to the humidity in DET area ENV..SQZ_BOARD_HU.

ACS
(19-04-2024 14:25 - 19-04-2024 14:45) On site
Status: concluded
Description: Det Humidity intervention by ACS Expert OnCall, steam producer restarted. Humidity values again in threshold.

ALS
(19-04-2024 13:00 - 19-04-2024 15:20) From remote
Status: concluded
Description: The issue was at level of optic amplifier. Aymeric contacted ISYS OnCall expert (C. DeRossi) who will come on site tomorrow morning to replace the device at WE with a spare one.

TCS
(19-04-2024 16:36 - 19-04-2024 17:00) From remote
Status: concluded
TCS_WI_CO2_PWROUT out of range. Nardecchia asked me to change the DMS thresholds.

Guard Tour (UTC)
17:01 - 17:40
19:01 - 19:28

Images attached to this report
Detector Characterisation (Spectral lines)
direnzo - 18:33 Friday 19 April 2024 (64035) Print this report
Comment to Sideband structure around the 50 Hz mains line (64000)

ERRATA CORRIGE: the sidebands at 44 and 56 Hz are non-physical. These are just an aliasing artefact, consequence of an improper chunk-by-chunk downsampling to produce the resulting spectrogram.

Figure 1: fixed version of the spectrogram in the range 42-58 Hz.

Figure 2: animated GIF that compares the correct spectrogram and the wrong one in the main entry.

Images attached to this comment
Detector Characterisation (Broadband noise)
direnzo - 18:13 Friday 19 April 2024 (64033) Print this report
Comment to yesterday fly-over (64027)

I've checked with some Q-scans if the transit of the helicopter caused glitches in Hrec.

Figure 1: During the first transit at 14:46 UTC no excess noise was visible in Hrec, while in the CEB microphone is clearly visible the sweep caused by the helicopter.

Figure 2: during the transit at 14:59 UTC some barely coincident noise is visible in Hrec and the CEB microphone. The frequency is not exactly the same, so this may have just happened by chance.

Figure 3: some excess noise but no evident correlation at the time of the transit at 15:11 UTC. Nothing evident during all the other passages of the helicopter.

Images attached to this comment
Environmental Monitoring (Environmental Monitoring)
Paoletti, Fiori, Tringali - 18:02 Friday 19 April 2024 (64032) Print this report
Comment to Test of automated injections using ENV_MAIN (63714)

We tested the sensitivity of the top-stage BS accelerometers at three different levels of acoustic injection (nominally 0.03 - 0.04 - 0.05 V).

Noise was filtered from 8 to 2000 Hz, but the actual noise produced was only from 20 Hz and up, as the speaker is unable to go lower.

 

The fourth injection (18:04:40 UTC - (80 -100) Hz, 300 sec, 0.04 V) aimed to produce the same level around the frequency of ~93 Hz (without generating out-of-band noise) where one of the horizontal BS F0 accelerometers (Sa_BS_F0_ACC_H3_500Hz) is usually excited during acoustic injections, in order to check whether the coupling is linear or not.

Unfortunately, the filter was too narrow, and the noise spectral density at 93 Hz was lower than expected.

However, we can say that generating a higher level by a factor of 2 (with no noise at lower frequencies) resulted in an increase of the peak by about a factor of 2 (difficult to estimate accurately). It appears that there is no upconversion and the system is "linear."

 

During this test we also noticed that there is some (unexplained) coherence between the upper stage F0 accelerometers and the lower external magnetometers (this is also the case in other towers besides BS).

At first glance one might think of general coupling due to the external accelerometer cables running not too far from the magnetometers (as indeed they are), but there are high-level signals in the acceleration spectrum that have no coherence. If it were a coupling from the cable, it should be broadband.

Images attached to this comment
AdV-DET (Commissioning)
gouaty, menzione, masserot - 16:47 Friday 19 April 2024 (64031) Print this report
Updated Shutter flag in the DMS

We have updated the Shutter flag in the DMS (configuration of process DetMoni). In case the slow shutter motor remains stuck after step 109 of the lock acquisition, a red flag will be displayed.

We plan to further update the flag logic at the next maintenance to also perform some checks during the lock acquisition after the shutter closure.

Detector Characterisation (Broadband noise)
fiori - 15:18 Friday 19 April 2024 (64029) Print this report
Comment to yesterday fly-over (64027)

Indeed around the time of the unlock (yesterday 15:22 UTC) there has been also an earthquake (M 5.6 - 9 km W of Sulusaray, Turkey, 15:11 UTC)

The unlock was likely due to it, as reported by A.Magazzu in https://logbook.virgo-gw.eu/virgo/?r=64020.

This makes difficult to disentangle if there has been aslo an impact from the helicopter.

Images attached to this comment
Virgo Runs (O4b)
Sposito - 15:01 Friday 19 April 2024 (64028) Print this report
Operator Report - Morning shift

ITF in SCIENCE for the whole shift.

Pending actions

Other
( - ) ALS WE Laser has to be switched back on at the first unlock

Images attached to this report
Detector Characterisation (Broadband noise)
fiori, bersanetti, arnaud - 9:29 Friday 19 April 2024 (64027) Print this report
yesterday fly-over

Yesterday an helicopter was seen flying close to the Virgo buildings. This was in the late morning but the ITF was not locked. And again in the afternoo (14:30 to 15:30) when the ITF was locked.

Some indication of the passages are in the first plot, showing the RMS of some microphones in the band around 50Hz.

Helicopther noise is seen also at NEB and WEB. The sound signal is visible the band up to 200Hz, louder around 30 Hz (this can bee seen in Figure 2).

To a first look no evident glitch is seen in Hrec.

Yet, the unlock (around 15:20) is associated to scattered light arches in hrec and in B8 photodiode. At that time, judgeing from the sound level in microphones, the helicopter was close to WEB.

A correlation of the two events is possible (Figure 3).

But I would advise a better look with more accurate tools.

Images attached to this report
Comments to this report:
fiori - 15:18 Friday 19 April 2024 (64029) Print this report

Indeed around the time of the unlock (yesterday 15:22 UTC) there has been also an earthquake (M 5.6 - 9 km W of Sulusaray, Turkey, 15:11 UTC)

The unlock was likely due to it, as reported by A.Magazzu in https://logbook.virgo-gw.eu/virgo/?r=64020.

This makes difficult to disentangle if there has been aslo an impact from the helicopter.

Images attached to this comment
direnzo - 18:13 Friday 19 April 2024 (64033) Print this report

I've checked with some Q-scans if the transit of the helicopter caused glitches in Hrec.

Figure 1: During the first transit at 14:46 UTC no excess noise was visible in Hrec, while in the CEB microphone is clearly visible the sweep caused by the helicopter.

Figure 2: during the transit at 14:59 UTC some barely coincident noise is visible in Hrec and the CEB microphone. The frequency is not exactly the same, so this may have just happened by chance.

Figure 3: some excess noise but no evident correlation at the time of the transit at 15:11 UTC. Nothing evident during all the other passages of the helicopter.

Images attached to this comment
Detector Characterisation (Glitches)
mwas - 8:16 Friday 19 April 2024 (64026) Print this report
Comment to Scattered light glitches after EIB control improvements (64022)

This is very interesting. My interpretation of to these results is:

  • The work on improving the EIB control has been effective. The scattered light glitches that its motion produces during bad weather is at frequencies below 20Hz, and maybe even 15Hz, which will be more difficult to improve on.
  • The main source of scattered light glitches 30Hz-50Hz during bad weather comes from the west end building. The WE suspension local control signal Sa_WE_F0_X_500Hz, may mean the suspension is moving, or that the ground around the suspension is moving. A more detailed analysis of all the position sensors in the WE building is needed to determine what is the source of scattered light in the WE building, but it is unlikely to be the mirror itself.
Virgo Runs (O4b)
gherardini - 6:59 Friday 19 April 2024 (64025) Print this report
Operator Report - Night shift
The ITF kept the lock all the shift, science mode stopped from 2:34UTC to 2:53UTC due to squeezing disengage.

- ALS:
at 21:35UTC the west end green laser switched off.

No DMS alerts in the last 8 hours.

- guard tours (UTC):
21:01 --> 21:28
23:50 --> 0:19
1:05 --> 1:35
3:10 --> 3:40
Images attached to this report
Virgo Runs (O4b)
amagazzu - 22:57 Thursday 18 April 2024 (64020) Print this report
Operator Report - Afternoon shift

Upon reaching the site I found the ITF relocking. After a brief alignment of the PR/SR Mirrors, LOW_NOISE_3_SQZ was reached at the first attempt at 13:50 UTC, ITF back in Science Mode from 15:32 UTC.
At 15:07 UTC I set the ITF in Commissioning Mode to allow the planned ISC activity, DIFFp set point error signal test, carried out by Mantovani. The work could not be concluded due to an unlock at 15:22 UTC due to an earthquake (M 5.6 - 9 km W of Sulusaray, Turkey, 15:11 UTC). After various attempts we were able to reach LOW_NOISE_3_SQZ at 16:53 UTC, and the second planned activity, ENV Acustic Injection, started (see report #64024).
ENV Activity concluded at 18:11 UTC and ITF back in Science Mode. A quick adjusting period, from 18:16 UTC to 18:17 UTC, was done to allow the switch off the Speaker PDU.
The ITF unlocked at 19:34 UTC, relock in progress.

Guard tour (UTC):
17:06 - 17:44
19:03 - 19:30

Images attached to this report
Detector Characterisation (Glitches)
direnzo, longo - 22:27 Thursday 18 April 2024 (64022) Print this report
Scattered light glitches after EIB control improvements

Prompted by Michal, I verified if the occurrence of Scattered Light glitches from External Injection Bench motion associated with bad weather conditions has changed after the recent intervention and improvement of the EIB ground noise correction: #63763.

I examined the conditions during the last three main events of bad weather and Scattered Light glitches: February 25-26, March 26-27, and April 1-2.

Figure 1: time series of the V1:ENV_CEB_SEIS_W_50Hz_rms_0.1_1Hz during the three examined periods. In all three cases, the level of ground motion in the CEB is comparable.

Figures 2, 3 and 4: glitchgrams for Hrec during the three examined periods. The bottom time series represent the glitch rates for those triggers with frequency at peak between 20 and 2048 Hz, and SNR > 6.5. One interesting thing to notice is the presence of additional, very loud glitches with frequency at peak of about 90-100 Hz, associated with the last period of bad weather. Investigations are ongoing to understand their origin and if they are related or not to the ground motion.

Figures 5, 6 and 7: same as above but for the V1:LSC_SRCL channel, which in previous entries (#63761 and , #63420) was observed with Scattered Light glitches most correlated with the motion of the EIB, represented by the channel V1:SBE_EIB_GEO_H2_200Hz. In the period April 1-2, almost no glitches are present above 20 Hz, while in the other two periods, the rate is very high and correlated with the ground motion. The fact that a similar reduction in the rate of glitches is not visible in Hrec suggests a different origin for them.

Figure 8: a few Scattered Light glitches present in LSC_SRCL and their prediction with the SBE_EIB_GEO_H2_200Hz channel, as described in #63761.

Figure 9: the Scattered Light visible in Hrec is mostly explainable by the motion of the West End mirror. Using the technique described in #63761, the most correlated channel found is Sa_WE_F0_X_500Hz. In the attached text file, the list of all channels with correlation larger than 20%. The reconstruction is not perfect due to the sparseness and irregular shape of the glitches.

Images attached to this report
Non-image files attached to this report
Comments to this report:
mwas - 8:16 Friday 19 April 2024 (64026) Print this report

This is very interesting. My interpretation of to these results is:

  • The work on improving the EIB control has been effective. The scattered light glitches that its motion produces during bad weather is at frequencies below 20Hz, and maybe even 15Hz, which will be more difficult to improve on.
  • The main source of scattered light glitches 30Hz-50Hz during bad weather comes from the west end building. The WE suspension local control signal Sa_WE_F0_X_500Hz, may mean the suspension is moving, or that the ground around the suspension is moving. A more detailed analysis of all the position sensors in the WE building is needed to determine what is the source of scattered light in the WE building, but it is unlikely to be the mirror itself.
Environmental Monitoring (Environmental Monitoring)
Fiori, Paoletti, Tringali - 20:14 Thursday 18 April 2024 (64024) Print this report
Comment to Test of automated injections using ENV_MAIN (63714)

We performed a set of four acoustic injections in CEB with the AcousticInjectionCEB VPM process:

1) 17:07:55 UTC - (8 - 2000) Hz, 600 sec, 0.03 V

2) 17:21:05 UTC - (8 - 2000) Hz, 600 sec, 0.04 V  (25 min glitch at ~17:29:24 UTC)

3) 17:33:48 UTC - (8 - 2000 )Hz, 600 sec, 0.05 V

4) 18:04:40 UTC - (80 -100) Hz, 300 sec, 0.04 V

The directory path of output files is /virgoData/NoiseInjections/AcousticInjectionsO4/output. The list of file injections is reported below:

1) AcousticColored_NOISE_CEB_DetTerrace-1397495261.txt

2) AcousticColored_NOISE_CEB_DetTerrace-1397496052.txt

3) AcousticColored_NOISE_CEB_DetTerrace-1397496814.txt

4) AcousticColored_NOISE_CEB_DetTerrace-1397498666.txt

Detector Characterisation (Spectral lines)
Tringali, Spinicelli, Fiori - 18:11 Thursday 18 April 2024 (64018) Print this report
Comment to Sideband structure around the 50 Hz mains line (64000)

As Piernicola confirmed, the sidebands at 46.7 Hz and 53.3 Hz are the beating between 50 Hz and DIFFp_TX line at 3.3 Hz (purple curve).
Indeed, when the DIFFp_TX line was set to 4.8 Hz, there were two sidebands at 45.2 Hz and 54.8 Hz, respectively (blue curve).

Images attached to this comment
AdV-DET (Commissioning)
gouaty, masserot, mwas - 17:57 Thursday 18 April 2024 (64021) Print this report
OMC shutter opening: new command to avoid getting stuck at the end range

This afternoon we performed a few tests on the OMC shutter with the ITF in NI single bounce in order to find a solution to the problem of OMC shutter getting stuck at the opening.

Fig.1 shows a test when sent a MOVETOLIMIT command via VPM to open the shutter. In this case the shutter motor get stuck, and we stopped it by sending the STOP MOTION command.

We have tested the opening of the shutter by sending some MOVEREL commands with a defined number of steps. We have found that with about 36000 steps the power on B1s reaches a plateau. Adding a bit of margin, we decided to perform 42000 steps to open the shutter. This is tested on Fig.2. We can see that it takes about 65 seconds to accomplish this motion.

We have then replaced the MOVETOLIMIT command by the MOVEREL command for the opening of the shutter in the class SHUTTER_OPENING of DET_MAIN. In the DET_MAIN.ini file, we have added the parameter nominal_open_steps = 42000, and we have updated the opening_duration to 80 seconds.

The opening and then closing of the shutter are tested with the automation on Fig.3. The closing is still performed with the MOVETOLIMIT command in order to be sure that we always start opening the shutter from the same position.

It was then possible to relock the ITF in Low Noise 3 at first trial.

Images attached to this report
Virgo Runs (O4b)
ruggi - 15:10 Thursday 18 April 2024 (64019) Print this report
Comment to Operator Report - Morning shift (64017)

The unlock due to bad weather was not associated to the limited range of the actuators, as happened other times. When the wind increased and reached 50 km/h in a few minutes, WE_MIR_CORR increased, but not enough to stay so close to the saturation (fig 1). The unlock happened during a clear drop of the sidebands, at the end of which some longitudinal loop was not very stable anymore (fig 2). The drop was associated to a misalignment of BS TY (fig 3) and PR_TY (fig 4). It is not clear to me which was the first which began to move, and what was the cause of this motion.

Images attached to this comment
Virgo Runs (O4b)
menzione - 15:00 Thursday 18 April 2024 (64017) Print this report
Operator Report - Morning shift

Upon arrival I found ITF in Science Mode.
ITF stable locked at LN3_SQZ (Science Mode) till 11:31 UTC when it unlocked due to the bad weather conditions. High wind activity.
According with Gouaty I set ITF in SINGLE_BOUNCE_NI in order to allow Romain on his investigation on OMC shutter and B1_PD3 noise.
TROUBLESHOOTING MODE set from 11:33 to 12:56 UTC. Activity concluded. Relock in progress...

NO DMS events Monitor to report
 

Images attached to this report
Comments to this report:
ruggi - 15:10 Thursday 18 April 2024 (64019) Print this report

The unlock due to bad weather was not associated to the limited range of the actuators, as happened other times. When the wind increased and reached 50 km/h in a few minutes, WE_MIR_CORR increased, but not enough to stay so close to the saturation (fig 1). The unlock happened during a clear drop of the sidebands, at the end of which some longitudinal loop was not very stable anymore (fig 2). The drop was associated to a misalignment of BS TY (fig 3) and PR_TY (fig 4). It is not clear to me which was the first which began to move, and what was the cause of this motion.

Images attached to this comment
Detector Characterisation (Spectral lines)
Tringali, Fiori - 14:44 Thursday 18 April 2024 (64013) Print this report
Line at 47.5 Hz

Looking at the spectrogram of Hrec, we observed a peak at 47.5 Hz which arose on April 15th, ~01:00 UTC (between two locks), see Figure 1 and 2.
It could be related to the F7 crossbar mode of the NI tower that we measured by magnetic injections to be at 47.65 Hz (VIR-0300A-24).
In this case, it seems that the line has shifted slightly in frequency.

Images attached to this report
Virgo Runs (O4b)
ruggi - 12:17 Thursday 18 April 2024 (64016) Print this report
Comment to Operator Report - Afternoon shift (64003)

Yesterday at 19:24 UTC the ITF unlocked because of a saturation of WE MIR actuation (fig 1). The correction was progressively increasing in the latest half an hour and it was often very close to 10 V in the latest minutes (fig 2). It was due to an increasing of ground motion between 0.5 and 1 Hz (fig 3), typically due to the weather close to the site (for instance, strong rain or particularly stormy sea). That frequency component was the main responsible of the large correction (fig 4); improving the filters at that frequency has for sure an impact at 1.8 Hz, so any change needs to be tested in terms of stability. There is also the chance that something can be improved at the level of the top stage control, but also in that case, the margin of improvement without worsening other frequency regions is small.

Images attached to this comment
Detector Characterisation (Glitches)
fiori - 12:07 Thursday 18 April 2024 (64015) Print this report
Comment to long transient noises (63998)

Transients are see also in DET B8 DC (Figure 1). Signal SBE_SWEB_F0_z_LVDT_500Hz converted into velocity and low pass filtered (fcut 0.5 Hz, in order to remove large high frequency noise in this signal) seems to reproduce sufficiently well the shape: Figure 2. Also the second order of arches (weakly seen in the photodiode)  is similarly reproduced doubling the velocity, although not plotted.  Maybe there is a better signal to use that measure the bench motion?

Images attached to this comment
AdV-DET (Commissioning)
gouaty - 11:55 Thursday 18 April 2024 (64014) Print this report
Check of OMC shutter functionning in single bounce (data from maintenance)

The attached Figure 1 shows the time when the OMC shutter was opened for the OMC lock and scan during the last maintenance. One can see a glitch on SDB1_OMC1_T1 indicating when the shutter starts to move. The power reaches a plateau on B1s about 16 seconds later. But, as already mentioned by Michal in https://logbook.virgo-gw.eu/virgo/?r=64012 , the line at 1721 Hz on the spectrum of SDB1_OMC1_T1 is present for about 20 minutes indicating that the shutter motor was still working during all this time. The line disappear between 06h39 and 06h40 utc (see Figure 2).

Figure 3 shows the closing of the OMC shutter. In this case we can see a first glitch on SDB1_OMC1_T1 when the shutter starts to move, and a second glitch about 35 seconds later when the shutter stops. The power on B1s reaches zero about 22 seconds after the first glitch. In this case the line at 1721 Hz on SDB1_OMC1_T1 disappear right after the second glitch, meaning that the shutter motor is properly stopped (Fig.4). Thus, it looks like the end limit sensor is still working for the shutter closing. The issue seems to be only for the opening.

Images attached to this report
Search Help
×

Warning

×