Excess noise on all LSC channels

Figure 1. Comparing the spectrum of yesterday to the beginning of the year, the noise level of SRCL, PRCL, MICH is a factor few higher than before. Especially on PRCL. This is also the case of noise on the SSFS quadrature. 

The question is what it is and where it comes from. The noise is likely to be present on the laser frequency, and then polluting all LSC channels. It may be related to the higher noise level of the LNFS.

Figure 2 The more structured noise that is visible in SRCL between 300Hz and 3kHz is very coherent with the excess noise in the LNFS. So that part is clearly due to the more noisy LNFS. For the excess noise in PRCL, and the excess noise in SRCL below 300Hz it is less plausiable. As there is no coherence with the LNFS phase noise, and the LNFS broaband noise below 300Hz is the same as it was at the beginning of the year.

Figure 3 shows yesterday in purple, Friday last week in red, and the beginning of the year in blue. Some version of the pole at 500Hz noise is back, it is clearly visible on SIB2 RFC 8MHz I, the level doesn't appear to be stable as it is different on Friday last week and yesterday, and the changes in noise level of PRCL and SSFS quadrature are correlated with those pole at 500Hz noise changes visible on RFC 8MHz I. 

Figure 4 Looking at data of various nights with arms locked, the pole at 500Hz noise seems to have appeared on October 7. It would be important to look at that more precisely to see at what time the extra noise appeared. One hardware activity on that day was the realignment of the phase camera, and maybe a change in the splitters for the local oscillator of the phase camera https://logbook.virgo-gw.eu/virgo/?r=69877

Figure 5. Searching more precisely it looks like the problem started around 19:00 UTC, there was an interferometer unlock from LN2 at that time.

7 comments

mwas · 16 Oct 2026 · 10:41 #69939

The pole at 500Hz noise that appeared on Oct 7 around 19:00 UTC is also visible in other channels earlier in the INJ chain.

Figure 1 and 2 compare the time before the issue started (purple) with a time after (blue) respectively on Oct 8 and Oct 14. All the times are with the interferometer in LN2 or LN3. The additional noise is visible clearly also on the Audio band monitoring of the EOM transmission, on the EOM correction, and much less clearly on the PMC transmission.

If the extra noise is visible on the EOM transmission (INJ_EAB_EOM_TRA_AUDIO) both with the IMC locked and unlocked, then it should make it easier to find. As the IMC can be excluded from the investigation, but most likely the problem becomes invisible in that case, as the laser amplitude noise will dominate everything with the PSTAB loop open.

fiori, mantovani · 16 Oct 2026 · 11:42 #69940

We run a BruCo, coherences are computed up to 1kHz:
https://scientists.virgo-gw.eu/DataAnalysis/DetCharDev/users/fiori/bruco/Hrec_hoft_1475998223/bruco.html

 

fiori, mantovani · 16 Oct 2026 · 16:40 #69943

here the BruCo using as target LSC_PRCL: https://scientists.virgo-gw.eu/DataAnalysis/DetCharDev/users/fiori/bruco/LSC_PRCL_1475998223/bruco.html

 

gosselin, melo · 19 Oct 2026 · 16:42 #69956

This morning we did some tests to try to understand the excess of noise
Here are the GPS :

09:38 UTC - INJ AA loop open (from DSP card)
09: 59 UTC - IMC unlock (from VPM)
13:18 UTC - PSTAB open

Surprisingly the cycle IMC unlocked / locked arounf 10 am made the noise as seen on RFC_8MHz disappear. This might go in favour of some saturation in the frequency loop actuators. 
However, I checked some IMC unlocks of the previous days and the noise was present both before and after the unlock. 
I checked if there was other changes in the INJ parameters but could not spot anything obvious. 

gosselin · 21 Oct 2026 · 08:54 #69964

The noise reappeared after the unlock of yesterday 20/10 at 8:17 UTC (plot 1, RFC_8MHz has been band pass filter in the 10-40Hz band).

The noise appeared during the unlock of the 07/10, on the operator report it is said that the ITF unlocked because of the thunder around 18:51 UTC. 
I could not find anything that makes those two unlocks different from other unlocks in which the noise did not appear. (signals checked : IMC alignment, MC_Z, PMC_PZT, ML_TH, EOM_CORR_max...) 

This morning I tried to make a cycle of IMC unlock/lock but it did not make the noise disappear. 


EDIT : I added a channel to have an easy access to this addiotnal noise. The RMS of the RFC_8MHz signal betwenn 15Hz and 45Hz 
V1:DQ_BRMSMon_BRMS_INJ_RFC8MHZ_15Hz_45Hz_SIB2_RFC_8MHz_I 

mwas · 21 Oct 2026 · 15:39 #69965

Figure 1. When the noise increase the 6MHz sideband on the RFC photodiode gets two additional sidebands at +/-1.05 MHz around it. That is the IMC free spectral range. This would indicate that the noise has a bandwidth of several MHz, that we see it at +/-1MHz away directly in the photodiode sample data, and at +/-2MHz less directly on the demodulated 8MHz signal. 

Most INJ/PSL loop have an UGF of ~100kHz or less, so it cannot be a photodiode that saturates and propagate noise in a loop to create this noise. As the loops will have some kind of low pass filtering to keep the UGF at 100kHz or less. It could be a fast actuator having saturations, as that is after the filtering. 

There are several actuators that are able to act with a MHz bandwidth:

  • Master laser noise eater loop, that is fully analogic and embedded in the master laser acting on the current of the pumping diodes
  • The fibered EOM, the Op Amp of the fibered EOM electronics have a bandwidth of 70MHz. There should be a monitoring output for the fibered EOM electronics, but I don't know if that is acquired somewhere
  • The solid state EOM, which should have a resonant circuit for the PMC sideband generation, but also be able to have a broadband feedback to act on the laser light, as it was used for laser frequency control before the installation of the fibered EOM

The fibered EOM electronics seems to be most likely issue, as they were modified to lower their output noise but increase their risk of saturation. Maybe there is a way of understanding that by acquiring the monitoring EOM corr output. The alternative is to reduce the RMS of the signal at the input of that electronics, while keeping the same gain, which means locking the IMC with a lower gain in the loop. Either by adding a passive attenuator at the input of the fibered EOM electronics, or by adjusting the IMC ramp auto.

Figure 2 During the night there have been small fluctuations in the level of the pole at 500Hz noise while the RFC/IMC remained lock. Maybe this can give us further ideas on where the issue is.

craighero, gosselin, spinicelli · 22 Oct 2026 · 16:49 #69972

This morning we went in the Atrium of the Laser lab to investigate on this additional noise, in particular concentrating on the fiber EOM electronics. 

We thus looked at the spectrum of the EOM corr directly at the output of the amplifier (see fig. 1).  The spectral noise level in the MHz band showed a lot of spikes, where we normally should only have flat noise of the order few tens of nV/sqrt(Hz).

However, we noticed that, manipulating around the electronics box, we were able to remove or make appearing this noise (see fig.1 between 9h30 and 10h UTC). We reconducted this to a grounding problem, which probably appeared after the lightning that caused an unlock of IMC.

To solve the problem, we switched off the (homemade) power supply of the electronics, plugged on a different UPS wall plug, and restarted everything. As a result, the noise disappeared. Moreover, we were not anymore able to induce it by manipulating the box.

For the time being, the noise is not visibile on the RFC_I_8MHz.