Virgo Logbook
UTC--:--:--
GPS-
Reports
AdV-DAQ›Data Acquisition and Global Control #68964

DAQ restart after the computing shutdown


 2026-04-02

The DAQ recovery, after the computing shutdown,  started on 2026-04-02-18h28m45-UTC once the CmNames server and the VPM server were restarted and that all the expected hosts (rtpc, olserver and stol) were alive .

We restarted  fisrt all the storage and data collection parts

  • raw stream on stol01 and stol02  hosts
  • rawfull, rds and trend streams on stol03 host 
  • the data collection parts running  on
  • operations performed between 2026-04-02-18h28m48-UTC and  2026-04-02-18h38m44-UTC 

As everything seems to run correctly , we continued by restarting all the servers involved

  • in the data access part 
  • in the Detector Monitoring System 
  • in the Automation part 
    • The PyHVAC server was unable to retart due to
      • the missing /dev/shm/zFbsIng imput SHM
      • and later the missing  input channels  V1:HVAC_INJ_TE_OUT_SET 
      • server fully recovered the  2026-04-07-08h27m37-UTC
  • in the Image readout 
  • operations performed  between 2026-04-02-18h39m15-UTC and 2026-04-02-19h08m44-UTC

We left all DAQ running during 1 hour to check that everything ran smoothly, thank to the availabilty of the DMS and VIM web pages.

 Then we continued by

We left all the things running during the nigth to perform a more accurate check the next day


 2026-04-03

We found that a lot of Ethernet devices (lnfs, sqz, power suppplies ) not any more recheable .  

For  DAQ/DET ethernet devices

  • the DaqBoxes  were reachable 
  • the SBD power supplies were not reachable.
  • the SDB internal switches were reachable 
  • the SWEB QD  RD482-ETH bridge was not reachable, meaning the B8_QD{1,2}  shutters and Vbias were not anymore remotely driven and monitored

Thanks to the local support, the  SBD power supplies  remote monitoring/driving were recovered . 

To recover remote monitoring/driving B8_QD{1,2},

  • the SWEB_PowerUnit12 was turned off/on and fortunately it was enough to recover this device.
  • as the internal Timing mezzanine was switched OFF/ON to, the SWEB bench DBoxes were reconfigured 
  • to recover the correct running conditions , the SWEB rach DBoxes were reconfigured too and the Acl's SWEB_rtpc servers restarted
  • operations performed between 2026-04-03-09h19m33-UTC  and 2026-04-03-09h37m46-UTC

Easter break

During the Easter break, the olserver115 became unreachable around 2026-04-03-19h34m38-UTC . The MdVim server has been restarted temporaly on the olserver118  at 2026-04-04-04h20m30-UTC.

The olserver115 host has been recovered by the IT department and the MdVim server is now running on its host since  2026-04-07-06h32m25-UTC


2025-04-07

All the Fbs servers were restarted with a new release v8r24p0 

  • operations performed between 2026-04-07-15h03m20-UTC and 2026-04-07-15h08m29-UTC