Arm scans: Astigmatism amplitude and orientation with RH off

Motivation for the shift

During this shift, several arm scans are made in order to characterize the optical properties of the North and West cavity. The scan will be used in order to:

-> Measure the astigmatism amplitude. From previous measurement (66835), the astigmatism amplitude appeared to be smaller in the North arm when the ring heater is turned off. No measurement has been made for the West arm since the RH were turned off during the change of the WE mirror. The data from this shift will be used to redo the measurement in both arms.

-> Discrepancy between the characterization made at LMA and from scan (VIR-0562A-25). According to previous measurement, there is a discrepancy between the expected g-factor and what is measured from the scan. The estimation will be done again and for both arms.

-> Most of the scans are made with a misalignment of the end mirrors in order to measure the orientation of astigmatism.

Shift report

Date of the shift : 15th December 2025

The table below shows the tasks performed and their time in UTC. The scans are run with the command CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.), where one iteration corresponds to one descending ramp + one ascending ramp. One iteration produces two scans, each one is 60 seconds long.

Time (UTC) Actions Comments
10h29 LOCK_BEATING_BOOST_ON  
10h42 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
11h03 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.3urad
 
11h13 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
11h34 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TY+=0.3urad
 
11h43 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
12h04 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.29urad
TY+=0.08urad
 
12h13 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Cavity unlocked during scan
at 12h21
12h21 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.29urad
TY+=0.08urad
Same misalgnment as before
12h35 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
12h57 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=-0.08urad
TY+=0.29urad
 
13h05 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Cavity unlocked during scan
at 13h19
13h20 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=-0.08urad
TY+=0.29urad
Same misalignement as before in order to finish the scan
13h31 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
13h53 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.26urad
TY+=0.15urad
 
14h00 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Cavity unlocked during scan
at 14h17
14h18 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.26urad
TY+=0.15urad
Same misalignement as before in order to finish the scan
14h24 Run 2 iterations of scan with
CARM_SET_scan_FSR(numiteration = 2, f_FSR=110000,timescan = 60.)
Only two iterations missing due to the unlock
14h30 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=-0.15urad
TY+=0.26urad
 
14h33 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
14h55 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=0.21urad
TY+=0.21urad
 
14h58 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
15h19 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Misalignement of the end mirrors (NE and WE)
TX+=-0.21urad
TY+=0.21urad
 
15h24 Run 10 iterations of scan with
CARM_SET_scan_FSR(numiteration = 10, f_FSR=110000,timescan = 60.)
Scan ran successfully
15h45 LOCKED_ARM_IR
LOCK_BEATING_BOOST_ON
Run 5 iterations of scan with
CARM_SET_scan_FSR(numiteration = 5, f_FSR=110000,timescan = 120.)
The last scans are a test to see if the uncertainty is smaller with longer scans