In view of the opening of the SR tower, I setup the automation in the following way:

  • DET_MAIN in SHUTTER_CLOSED, then paused;
  • SUS_SR in MISALIGNED, then paused;
  • DRMI_LOCK in MISALIGNED_PR_SR, then paused;
  • ITF_LOCK in DOWN, then paused;
  • SUS_PR in MISALIGNED, then manual;
  • OMC_LOCK in TEMP_CONTROLLED, then manual;
  • INJ_MAIN in IMC_RESTORED, then manual;
  • ARMS_LOCK in LOCKED_ARMS_IR, then manual;
  • all other nodes unchanged.

As a consequence, the DMS and in general the webpages will not reflect the status of the interferometer anymore, as it is desumed from the state of ITF_LOCK.

For the following weeks, the nodes INJ_MAIN and ARMS_LOCK should be (almost) the only ones to be operated manually; they will not talk with one another, so people should take care of both:

  • INJ_MAIN: unless the FmodErr tuning is really needed, IMC_RESTORED is the target state

  • ARMS_LOCK: nothing above LOCKED_BEATING_BOOST_ON should be requested

2 comments

bersanetti · 30 Jan 2026 · 18:05 #68611

This afternoon I set the same configuration for the automation as last month, in view of the opening of the SR tower. The arms have been relocked from the ARMS_LOCK node.

berni, bersanetti, gouaty, menzione · 15 Oct 2026 · 15:03 #69933

WIth the SR tower under venting, we setup the automation in the following way:

  • DET_MAIN in SHUTTER_CLOSED, then paused;
  • SUS_PR in MISALIGNED, then paused;
  • SUS_SR in MISALIGNED, then paused;
  • DRMI_LOCK in MISALIGNED_PR_SR, then paused;
  • ITF_LOCK in DOWN, then paused;
  • OMC_LOCK in TEMP_CONTROLLED, then manual;
  • INJ_MAIN in IMC_RESTORED, then manual;
  • ARMS_LOCK in LOCKED_ARMS_IR, then manual;
  • all other nodes unchanged.