Reports 1-1 of 1 Clear search Modify search
Injection system (General activities)
casanueva, genin, gosselin, pillant - 19:10 Tuesday 16 October 2018 (43104) Print this report
Comment to Master laser swap (43103)

The AA sensing matrix has been remeasured and the loop in full bandwidth has been restored.

ACL_MATRIX_BEGIN    sensing_matrix    1    MCT_hNORM    FF_ACh    NF_ACh        MCT_vNORM    FF_ACv    NF_ACv
ACL_MATRIX_CH            MC_ty_err    ""        12.37         0.00     -2.28        0            0        0
ACL_MATRIX_CH            IB_ty_err    ""        19.67         0.00     -42.09        0            0        0
ACL_MATRIX_CH            MC_tx_err   ""        0             0         0            7.43        19.22    0.0
ACL_MATRIX_CH            IB_tx_err    ""        0             0         0            26.70           12.19    0.0
ACL_MATRIX_CH            IB_tz_err    ""        0             0         0            2.26        22.12    84.52
ACL_MATRIX_END        sensing_matrix

 

ACL_CONST_CH MC_ty_set    ""    0    LOOP_FREQ    1.4
ACL_CONST_CH IB_ty_set    ""    0    LOOP_FREQ    -2.1 #
ACL_CONST_CH MC_tx_set    ""    0    LOOP_FREQ    -1.5 #
ACL_CONST_CH IB_tx_set    ""    0    LOOP_FREQ    -0.2 #
ACL_CONST_CH IB_tz_set    ""    0    LOOP_FREQ    -14.5 #

Search Help
×