Today we have checked the delays between CAL_MIR/MAR_*_Z_CORR and Sc_MIR/MAR_*_Z_CORR for each mirror and marionette which should be consistent with the changes made in the DSPs :
- The marionettes have the same delay ~ 502 µs
- The mirrors have the same delay ~ 453 µs except for PR mirror which has ~ 666 µs
PR has been corrected today for aliasing but there is still an extra-delay of ~ 213 µs which is not seen in the other mirrors...