This night/morning we have put in operation large part of the software associated to the VCS-10.0 release. This release is dedicated to the CentOS7 upgrade wrap-up and to the (hopefully coming) Engineering Run at the end of April.
Further below is the provisional list of involved packages all installed in /virgoApp. The baseline of Basic/Core packages is the following (please use it for any not yet aligned software):
- use VirgoPolicy v2r6 (/virgoApp)
- use Fr v8r32p1 (/virgoApp)
- use Frv v4r28p4 (/virgoApp)
- use CSet v2r16 (/virgoApp)
- use Cm v8r12p5 (/virgoApp)
- use Cbf v4r13 (/virgoApp)
- use Cfg v8r06p2 (/virgoApp)
- use Fd v8r20p4 (/virgoApp)
For what concern the Python bindings the new versions now in use wrapping Cm v8r12p5 and Fd v8r20p4 are correspondingly PyCm v5r2 and PyFd v2r2.
PythonVirgoTools version has remained unchanged (v2r0)
Considering Virgo Online subdivisions in VPM, this is the situation in terms of process stop/restart from frozen versions:
Completed
- ADC7674
- Minitowers
- ISC
- Squeezer
- Injection
- TCS
- Suspension
- Data Collection
- Storage - Stol01
- Storage - Stol02
- Storage - Stol03
- Automation
- SMS host
Partially done
- Detector Environment Monitoring
- Vacuum
- Data Access
Not done
- Detector Monitoring
- Control Room
- DetChar
- Calibration-Reconstruction
Hopefully, the remaining processes (which stop/restart is supposed to be less invasive over Commissioning activities) will be dealt in the coming days once aligned versions will be made available.
Updated information over VCS-10.0 Release can be found online at:
https://wiki.virgo-gw.eu/Software_Management/VCS-10-0
-------------------------------------------------------------------------------------------------------------
Provisional VCS-10.0 software baseline
use CanAPI v3r10 (/virgoApp)
use libmodbus v3r1p40 (/virgoApp)
use libusb v0r3 (/virgoApp)
use VISA v0r2 (/virgoApp)
use PackageBuild v0r14 (/virgoApp)
use Glib v2r48p22 (/virgoApp)
use Cairo v1r14p82 (/virgoApp)
use GStreamer v1r10p22 (/virgoApp)
use Aravis v0r4p14 (/virgoApp)
use Comedi v0r8p10 (/virgoApp)
use FFTW v3r3p30 (/virgoApp)
use root v5r34p050 (/virgoApp
use VirgoPolicy v2r6 (/virgoApp)
use Fsm-AdV v1r0 Sa (/virgoApp)
use Filter-AdV v0p1 Sa (/virgoApp)
use Digfilt-AdV v1r6 Sa (/virgoApp)
use Fr v8r32p1 (/virgoApp)
use Frv v4r28p4 (/virgoApp)
use CSet v2r16 (/virgoApp)
use Cm v8r12p5 (/virgoApp)
use Cbf v4r13 (/virgoApp)
use Cll v1r20 (/virgoApp)
use Log v2r8 (/virgoApp)
use Cfg v8r06p2 (/virgoApp)
use AdvancedCommunication v5r10p1 (/virgoApp)
use Bc v5r6p1 (/virgoApp)
use Sb v2r4p1 (/virgoApp)
use ActuatorDrv v5r4 ISYS (/virgoApp)
use ActuatorSrv v4r3 ISYS (/virgoApp)
use ActuatorApp v5r1p1 ISYS (/virgoApp)
use Fm v4r07p1 (/virgoApp)
use Fd v8r20p4 (/virgoApp)
use PythonVirgoTools v2r0 (/virgoApp)
use Rtai v6r8 (/virgoApp)
use TolmDictionary v1r4 (/virgoApp)
use TolmUtilsForSa v1r3 Sa (/virgoApp)
use Damping-AdV v4r3p5 Sa (/virgoApp)
use GxNew v2r15 (/virgoApp)
use TolmBase v13r0 (/virgoStaging)
use Fbs v8r14p13 (/virgoApp)
use TolmFrameBuilder v4r7p13 (/virgoApp)
use DaqBox v13r0 (/virgoApp)
use TolmProcessor v13r0 (/virgoApp)
use Acl v0r52p13 (/virgoApp)
use Imaging v13r0 (/virgoApp)
use TolmComedi v13r0 (/virgoApp)
#Python
use PyCm v5r2 (/virgoApp)
use PyFd v2r2 (/virgoApp)
use PythonVirgoTools v2r0 (/virgoApp)
use TangoDAQSmsBridge v5r2 (/virgoApp)
use PyALP v2r0 (/virgoApp)
use PyRingHeater v1r2 (/virgoApp)
use PyPlc v0r0 (/virgoApp)
use PySbModi v3r1 (/virgoApp)
use PySb v1r1 (/virgoApp)
use PartCount v2r0 (/virgoApp)
use PyArtic v1r1 (/virgoApp)
#SAT Tango
use DspServer v2r8 Sa (/virgoApp)
use MchServer v4r2 Sa (/virgoApp)
use LcuServer v2r4 Sa (/virgoApp)
use PduServer v1r4 Sa (/virgoApp)
use SatServer v1r3 Sa (/virgoApp)
use TangoSrvMtr v5r0 Sa (/virgoApp)
#INJ Tango
use sdt2011 v7r0 (/virgoApp)
use Lnfs100 v7r1 (/virgoApp)
use SL_TempController v7r0 (/virgoApp)