Reports 1-1 of 1 Clear search Modify search
Injection system (General activities)
casanueva - 11:04 Thursday 22 March 2018 (40867) Print this report
Comment to Extra noise at high frequency readout by the RFC (40862)

Taking a look to the error signals of the north arm, it is clear that the extra noise found is coherent with the error signal of the reference cavity between 500 Hz and 1kHz. Also in the correction of the north arm we see that the rms is dominated by the contribution in this region, which difficults the lock (see Figure 1). The coherence with the RFC points to frequency noise, to be better understood.

Images attached to this comment