Reports 1-1 of 1 Clear search Modify search
AdV-AEI Squeezer Integration (external squeezer table)
De Laurentis, Tacca, Sorrentino - 10:34 Wednesday 21 February 2018 (40645) Print this report
Telescope out beam characterization
To allow the linear translation stage MT2 Mirror to work at full range, we replaced a part of the MT2 holder.

After the replacement, we realigned the telescope and characterized the out beam again.
The results are shown in the attached picture.

wox = 1.34 +/- .02 mm
woy = 1.39 +/- .01 mm

zosx = 7840 +/- 90 mm
zosy = 7104 +/- 70 mm

The beam, according with the input one, seems to be not perfectly gaussian.

Images attached to this report
Search Help
×

Warning

×