In order to understand the structures related to the SSFS we have lowered the SSFS gain at the final lock acquisition step from 400 to 300 to 200, see Figure 1 (brown = 400, purple = 300 and blue = 200).
there are several structures that shows a worsening of the corresponding factor in h.
the gps times are:
1195380434 for Gain 400 for 200 sec
1195380742 for Gain 300 for 200 sec
1195381031 for Gain 200 for 200 sec