AdV-SVS (Installation)
montanari, sorrentino - 22:30 Wednesday 21 October 2020 (49714) Print this report
ESQB1 cabling

Today we passed part of the SVS cables, starting with the ones for the AEI squeezer, from EE room to DET lab clean area. The work will be continued tomorrow.

Images attached to this report
Comments to this report:
montanari, vardaro, gherardini, nenci, sorrentino - 13:06 Monday 26 October 2020 (49744) Print this report

The cabling between DET lab and DET electronic room continued over Thursday and Friday. Now the cabling of AEI squeezer and SQB1 multiSAS are completed. We also added the cables for environmental sensing on ESQB1. Cables for the remaining ESQB1 hardware will be completed after the end of the works on AEI squeezer.

Images attached to this comment
tapia, vardaro - 0:24 Thursday 12 November 2020 (49907) Print this report

We continued the cabling work. In particular we are connecting all the passed cable from the DET lab to the Racks in the ESQB1 racks.

Power supplies:

We connected to the DCF (below) the following cables:

  • PS04c.001 - PLL Main PD1 PWR -  +/- 5V bias 5V
  • PS04c.002 - PLL Main PD2 PWR -  +/- 5V bias 5V
  • PS04c.003 - PLL SC PD1 PWR -  +/- 12V bias 5V
  • PS04c.004 - PLL SC PD2 PWR -  +/- 12V bias 5V
  • PS04a.001 - SC EOM Amp.PWR - 12V
  • PS04a.002 - Green EOM Amp.PWR - 5V
  • PS04a004 - Green PD PWR - +/-15V bias 15V
  • PS04a005 - IR Mon PD PWR - +/-15V bias 15V
  • PS04a006 spare

We connected an old cable of FIS PLL (label JPZ PD POWERS 2) Photodiode to the homodyne detector. The power supply is the bottom R&S power supply in the rack FDS2. Homodyne is powered at +/-18V using the channels 3 and 4 *current consumption ~125mA). The cable is connected to the rear side of the R&S Generator (photos 2 and 3) . 

DAQ:

We connected the following cables to the mezzanine (figure 4):

  • DAQ BOX 90 - mADC105 - CH0: SDC01a.011 - HD PD1 DC
  • DAQ BOX 90 - mADC105 - CH1: SDC01a.013- HD PD2 DC
  • DAQ BOX 90 - mADC105 - CH2:  SDC01a.009- HD AC SUM
  • DAQ BOX 90 - mADC105 - CH3: SDC01a.010 - HD AC DIFF
  • DAQ BOX 90 - mADC105 - CH4: SDC01a.008 - HD AC RF DIFF
  • DAQ BOX 90 - mADC105 - CH5:  HD CC Fast DRV
  • DAQ BOX 90 - mADC105 - CH6:  HD CC Fast Copy DRV

 

  • DAQ BOX 90 - mADC113 - CH6:  SDC01a.004 - Green PD DC
  • DAQ BOX 90 - mADC113 - CH6:  SDC01a.005 - IR Mon PD DC
Images attached to this comment
tapia, vardaro - 0:59 Saturday 14 November 2020 (49927) Print this report

On thursday 13th October we continued the cabling of the rack 5 and the FDS rack 2. The situation at the beginning of the week is shown in figure 1 and the situation after the end of the work is shown in figure 2 and 3. Now on the floor are lying only the spare cables used in O3. The new spare cables and some unused cables are placed between the rack 5 and the phase camera rack.

DAQ (figure 4):

  • DAQ BOX 090 - mADC 111 - CH2: SDC01a.001 PLL Main Ph.Noise.Mon
  • DAQ BOX 001 - mDemod 57 - CH0: SRF02a.008 Green.PD.RF
  • DAQ BOX 001 - mDemod 57 - CH1: SRF02a.009 HF.RF.LO

Line Driver/Receiver

  • Driver1 CH1:  SRF01a.001 PLL.SC.PD1.PWR
  • Driver1 CH2:  SRF01a.001 PLL.SC.PD2.PWR
  • Receiver1 CH1: SRF01a.004 HD.CC.Fast.DRV
  • Receiver1 CH2: SRF01a.005 HD.CC.Fast.Copy DRV

RF (DDS 2nd module from the top):

  • CH1 SRF02a.003 SC.EOM.Amp.RF
  • CH2 SRF02a.004 Green.EOM.Amp.RF
  • CH3SRF02a.005 SC.EOL.Amp.RF
  • CH4 SRF02a.006 Green.AOM.Amp.RF
Images attached to this comment