Allocca, Swinkels - 0:03 Wednesday 09 October 2019 (47159) Print this report
Work on the etalon loop

Today we worked a bit on the etalon loop. In particular, we changed the code in order not to send negative correction to the power supply. Secondly, we added few lines in order to keep memory of the correction working point after the loop is dis-engaged. The loop is left on. 

Comments to this report:
mantovani - 8:22 Wednesday 09 October 2019 (47160) Print this report

The corrections are already clipped at the DAC level from 0 to 20 V. And I also restored the correct set point 19.57 for NI and 19.88 for WI

 