Reports 1-1 of 1 Clear search Modify search
Virgo Runs (O3)
Montanari - 23:04 Sunday 14 April 2019 (45639) Print this report
Operator Report - Afternoon Shift Apr 14

ITF in Science Mode until 20:21UTC, when unlocked (see 1st plot).
Left in locking.

Environment
In the afternoon, winds increased a little, reaching 45kmh at 15:15UTC.

Images attached to this report
Comments to this report:
ruggi - 10:52 Monday 15 April 2019 (45641) Print this report

The unlock is due to a failure of NI marionette control, in coincinence with several seconds of data loss from Sc_NI control boards. The same kind of unlock occurred in C11 (see 43070).

Images attached to this comment
masserot, bouedo - 5:35 Tuesday 16 April 2019 (45646) Print this report

The Sc_NI data lost are due to the fact that no data were sent by Sc_NI to the DAQ.

Here the report of the SUSP_Fb server

019-04-14-20h21m37-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1239308514.000000000: Sc_NI: 62 channel(s) filled (added data min: 3228 max: 3228)
2019-04-14-20h21m38-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source Sc_NI (version 7) stopped
2019-04-14-20h21m38-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): Sc_NI - Unexpected source(s): none - Source with all data lost: DAQ_DEMOD_TIMING_1
2019-04-14-20h21m44-UTC>INFO...-[TolmFrameBuilderSource::SetUp] New source Sc_NI (v7) with GPS time: 1239308522.205111980
2019-04-14-20h21m44-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): none - Unexpected source(s): none - Source with all data lost: Sc_NI
2019-04-14-20h21m45-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1239308522.000000000: Sc_NI: 62 channel(s) filled (added data min: 2051 max: 2051)
2019-04-14-20h21m45-UTC>INFO...-CfgReachState> Golden(Golden) Ok



2019-04-15-14h42m08-UTC>WARNING-[TolmFrameBuilder::TryMerging] frame: 1239374545.000000000: merging is done on timeout
2019-04-15-14h42m08-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1239374545.000000000: Sc_NI: 62 channel(s) filled (added data min: 3055 max: 3055)
2019-04-15-14h42m09-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source Sc_NI (version 7) stopped
2019-04-15-14h42m09-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): Sc_NI - Unexpected source(s): none - Source with all data lost: DAQ_DEMOD_TIMING_1, LSCToSUSP
2019-04-15-14h42m15-UTC>INFO...-[TolmFrameBuilderSource::SetUp] New source Sc_NI (v7) with GPS time: 1239374553.387150287
2019-04-15-14h42m15-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): none - Unexpected source(s): none - Source with all data lost: Sc_NI
2019-04-15-14h42m16-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1239374553.000000000: Sc_NI: 62 channel(s) filled (added data min: 3871 max: 3871)

 

Search
×