Reports 1-1 of 1 Clear search Modify search
Environmental Monitoring (Environmental Monitoring)
fiori - 15:20 Tuesday 19 March 2019 (45318) Print this report
EIB and LB microphones OFF because of failure of conditioning unit

The Nexus conditioning unit powering the LB and EIB microphones is faulty: it does not power on. I removed it in order to be tested in the ELE lab.

DMS action; shelve for 1 WEEK the channels ENV_EIB_MIC and ENV_LB_MIC

Comments to this report:
fiori, paoletti - 16:47 Thursday 21 March 2019 (45338) Print this report

The problem was in the power adaptor that broke. ELE team replaced it. Now the system is back in operation. The ENV_LB_MIC and ENV_EIB_MIC channels can be unshelved in DMS.