Reports 1-1 of 1 Clear search Modify search
AdV-DAQ (Data collection)
masserot - 7:17 Thursday 22 March 2018 (40859) Print this report
Sa_NE,Sc_NE , NEB_ADC_Moni0 and NEB_ADC_Moni1 data lost

This morning at  2018-03-22-04h58m08-UTC, the data sent by

  • the suspension Sa_NE and Sc_NE DSPs
    • 2018-03-22-04h58m09-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source Sa_NE (version 1) stopped
    • 2018-03-22-04h58m09-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source Sc_NE (version 5) stopped
       
  • the NEB_ADC_Moni0 and NEB_ADC_Moni1 ADC7674 boards
    • 2018-03-22-04h58m09-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source NEB_ADC_Moni0_0 (version 7) stopped
    • 2018-03-22-04h58m09-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source NEB_ADC_Moni1_0 (version 2) stopped
       

are not more received  by their framebuilders(SUSP_Fb and SNEB_Fb) while the data sent by the DaqBoxes are still present.

The ADC7674 SN17 and SN12  boards are VME boards located in the same crate as the VME Mux/Demux one, used to collect the NE suspension data .

One may suspect a trouble with the VMEcrate.

Comments to this report:
berni, carbognani - 10:20 Thursday 22 March 2018 (40866) Print this report
We went a NE and we discovered that both fuses of the VME Crate C79 were burned; we tried to substitute the fuses but they burned again.

We decided to change the VME Crate C79 with a spare one C56.

All the cables were reconnected and Alain from remote reconfigured the ADCs; everything was ok.