we insert a double notch to compensate for the PMC_PZT TF
-> double notch: f=8250 Hz; Qp=2.4; Qz=6.9 / f=20840 Hz; Qp=2.5; Qz=5.0
plot 1 & 2 gives the Bode and Nichols plot
(Rem.: OLTF is measured while PDH = 2,2 V)
# PMC lock with PD_PMC_>2018
The loop has 18 dB margin (use to be 15 db before)
Oscillation starts for PDH_pp >= 6.6 V
-> PDH_Meanvalue ~ 2,34 Vpp
Images attached to this report
Comments to this report:
cleva - 8:25 Thursday 22 March 2018 (40861)
Print this report
this integration has been done on the 6th of March