Data from Sa_WE DSP have some holes since 6th (both in online and offline streams), as reported in figure. These holes are usually 4 to 6 seconds long: their frequency is increasing and now occurs randomly every about 30 minutes, as you can see from the VIM "Long susp" tab.
Events are accomplished by the following information in the SUSP_Fb log:
2017-07-25-07h05m32-UTC>WARNING-[TolmFrameBuilder::TryMerging] frame: 1185001548.000000000: merging is done on timeout
2017-07-25-07h05m32-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1185001548.000000000: Sa_WE: 39 channel(s) filled (added data min: 9675 max: 9675)
2017-07-25-07h05m32-UTC>INFO...-[TolmFrameBuilderSourceManager::Clean] Source Sa_WE (version 4) stopped
2017-07-25-07h05m32-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): Sa_WE - Unexpected source(s): none - Source with all data lost: none
2017-07-25-07h05m33-UTC>INFO...-CfgReachState> Active(Active) Ok
2017-07-25-07h05m38-UTC>INFO...-[TolmFrameBuilderSource::SetUp] New source Sa_WE (v4) with GPS time: 1185001555.669704675
2017-07-25-07h05m38-UTC>INFO...-[TolmFrameBuilderSourceManager::PrintLog] Missing source(s): none - Unexpected source(s): none - Source with all data lost: Sa_WE
2017-07-25-07h05m38-UTC>WARNING-[TolmFrameBuilderSubFrame::FillChannels] frame: 1185001555.000000000: Sa_WE: 39 channel(s) filled (added data min: 6697 max: 6697)
2017-07-25-07h05m38-UTC>INFO...-CfgReachState> Golden(Golden) Ok
Two channels from Sa_WE are sent via TOLM also to Sa_NE. They are used for the GPIC control, and do not have any missing data.