Reports of 2616 Clear search Modify search
Virgo Runs (O4b)
gherardini - 6:58 Thursday 09 May 2024 (64214) Print this report
Operator Report - Night shift
The ITF kept science mode all the shift.

No DMS alerts in the last 8 hours.

- guard tours(UTC):
21:01 --> 21:32
23:20 --> 23:50
1:45 --> 2:15
3:25 --> 3:55
Images attached to this report
Virgo Runs (O4b)
gherardini - 6:56 Wednesday 08 May 2024 (64207) Print this report
Operator Report - Night shift
The ITF kept science mode all the shift.

- guard tours(UTC):
22:01 --> 21:29
23:05 --> 23:34
1:30 --> 2:00
3:35 --> 4:05
Images attached to this report
Virgo Runs (O4b)
gherardini - 22:59 Monday 06 May 2024 (64179) Print this report
Operator Report - Afternoon shift

In this afternoon shift science mode stopped from 15:35UTC to 18:30UTC for daily calibration and commissioning (RIN coupling vs MICH and PRCL offsets), the ITF unlocked at 15:58UTC with a DOWN command from my ITF_LOCK client, I missclicked on the metatron client instead to set DOWN the CALI node I did it for ITF_LOCK without realizing it; the relock was a bit longer with three fails two locking at CARM_NULL_1F and one meanwhile locking the OMC (#64183).

-guard tours(UTC):
17:11 --> 17:39
19:03 --> 19:30

Sub-system reports

Air Conditioning
from 14:50UTC the MC building air conditioning started to malfunction with a little increasing of the hall temperature (see plot); experts aware of the problem, an extraordinary maintenance of the system is foreseen for tomorrow.

Calibration
- 15:36UTC: CALIBRATING_DF_DAILY;

Images attached to this report
Virgo Runs (O4b)
gherardini - 22:59 Sunday 05 May 2024 (64175) Print this report
Operator Report - Afternoon shift
The ITF kept science mode all the shift.

No DMS alerts in the last 8 hours.

- guard tours (UTC):
13:06 --> 13:33
15:09 --> 15:39
17:57 --> 18:32
19:58 --> 20:33
Images attached to this report
Virgo Runs (O4b)
gherardini - 15:01 Saturday 04 May 2024 (64170) Print this report
Operator Report - Morning shift

The ITF kept science mode all the shift.

- guard tours(UTC):
5:11 --> 5:39
6:59 --> 7:25
11:10 --> 11:38

Sub-system reports

Other
FCEM_MotSwitch crashed and restarted at 8:22UTC.

Images attached to this report
Virgo Runs (O4b)
gherardini - 15:00 Friday 03 May 2024 (64161) Print this report
Operator Report - Morning shift

The ITF kept the lock all the shift, from 5:00UTC the sensitivity started to worsening and the BNS range went down to 35Mpc, this is because of at the relock the end green beams was not flipped out, I did it by hand to recover the standard sensitivity, science mode stopped from 5:13UTC to 5:17UTC.

Sub-system reports

Air Conditioning
eurothermServer2 stopped and restarted at 7:58UTC because of missing data from FCEM air conditioning system.

Other
FCEM_MotSwitch crashed and restarted at 8:30UTC.

Images attached to this report
Virgo Runs (O4b)
gherardini - 6:58 Monday 29 April 2024 (64125) Print this report
Operator Report
The ITF kept science mode all the shift.

- guard tours (UTC):
21:08 --> 21:37
23:15 -->23:45
1:30 --> 2:00
3:10 --> 3:40
Images attached to this report
Virgo Runs (O4b)
gherardini - 6:57 Sunday 28 April 2024 (64107) Print this report
Operator Report - Night shift
The ITF kept science mode all the shift.

- guard tours (UTC):
21:40 --> 22:10
23:50 -->0:19
1:55 --> 2:25
3:50 --> 4:20
Images attached to this report
Virgo Runs (O4b)
gherardini - 23:05 Friday 26 April 2024 (64108) Print this report
Operator Report - Afternoon shift

In this afternoon shift science mode stopped from 16:00UTC to 19:02UTC for daily calibration and commissioning (PRCL offset scan and ISC noise injections) and for troubleshooting from 14:45UTC to 14:48UTC to solve the problem with Hrec; the ITF unlocked during the commissioning and it relocked at the first attempt.

- guard tours(UTC):
17:40 --> 18:10
19:40 --> 20:10

Sub-system reports

ISC
- 18:24UTC: LSC injections (inject_lsc.py);
- 18:40UTC: ASC injections (inject_asc_test.py);
because of a lack of time injections on SSFS and PSTAB not done, it will be run tomorrow afternoon;

Other
from 14:07UTC to 14:45UTC we had a strange behavior of Hrec with the range going up and down randomly and the sensitivity too, it was because of a test done by Alain on a test version of Hrec that by mistake was writing in a wrong shared memory.

Images attached to this report
Comments to this report:
masserot - 20:15 Friday 26 April 2024 (64111) Print this report

Offline Hrec test setup

While installing an offline Hrec test setup in the CascinaTest Cm domain,  this afternoon I duplicated the Hrec configuration, updating the FD_IN parameters but forgotten to update the FDOUT ones .As consequence, when I started this offline server on the same host where the online Hrec server is running (olserver52), there were some troubles with the Hrec online  data .I didn’t realize it was creating problems as I was working with offline data and in the CascinaTest Cm domain. When I realized this , I contacted the Control room and I fxed the issue .

This issue started at 2024-04-26-14h08m02-UTC and was fixed at 2024-04-26-14h40m34-UTC

Virgo Runs (O4b)
gherardini - 22:59 Thursday 25 April 2024 (64101) Print this report
Operator Report - Afternoon shift

The ITF kept the lock all the shift, science mode stopped from 16:00UTC to 18:45UTC for calibration.

- guard tours(UTC):
13:01 --> 13:44
15:06 --> 15:34
17:50 --> 18:20
19:51 --> 10:22

Sub-system reports

Calibration
- 16:01UTC: Measurement of checkHrec, NE,WE,BS,PR,SR optical responses, and sensitivity (CALIBRATED_DF_SENSITIVITY);
- 17:48UTC: Measurement of actuators response for NE,WE actuators and NI,WI,BS marionettes (CALIBRATED_DF_PCAL);

DAQ
VPM stopped to work at 15:38UTC, process restarted.

Images attached to this report
Virgo Runs (O4b)
gherardini - 15:00 Wednesday 24 April 2024 (64089) Print this report
Operator Report - Morning shift

The ITF kept science mode all the shift.

Sub-system reports

DAQ
at around 8:33UTC the VPM stopped to work and became unreachable over the net, restarted thanks to Emmanuel (#64088).

Images attached to this report
Detector Operation (Operations Report)
gherardini - 15:01 Tuesday 23 April 2024 (64067) Print this report
Operator Report - Morning shift

The shift was dedicated to maintenance, here a list of the activity reported to the control room:

- standard Vacuum Refill from 6:00UTC to 10:00UTC (VAC Team);
- cleaning of central and mod cleaner buildings (Gargiulo with external firm: from 6:00UTC to 10:00UTC);
- HVAC: weekly checks and extraordinary maintenance fo the DET area UTA (Soldani 6:15UTC to 10:00UTC);
- SUSP: NE local control maintenance (Majorana from 7:55UTC to 9:40UTC);
- INJ: check of IMC working point and position from 6:22UTC to 6:32UTC;
- DET: OMC shutter driver replacement (#64070);
          OMC Lock in single bounce configuration from 6:49UTC to 6:55UTC;
          OMC scan in single bounce configuration from 7:03UTC to 7:24UTC
- TCS: chiller check and refill (Gargiulo 6:45UTC);
          thermal camera reference from 8:13UTC;
          power checks and power adjustment done by Ilaria;

all the activity completed at 10:00UTC, ITF relocked at the first attempt; the work on detection area air conditioning system created a big transient on the temperature (see plot) it prevented to use the squeezing that is suffering of the change of temperature (QNR on-call informed), for the time being we go on without the squeezing injected.

Sub-system reports

Air Conditioning
BACnetServer stopped and restarted at 9:57UTC because of missing data.

Images attached to this report
Virgo Runs (O4b)
gherardini - 6:59 Friday 19 April 2024 (64025) Print this report
Operator Report - Night shift
The ITF kept the lock all the shift, science mode stopped from 2:34UTC to 2:53UTC due to squeezing disengage.

- ALS:
at 21:35UTC the west end green laser switched off.

No DMS alerts in the last 8 hours.

- guard tours (UTC):
21:01 --> 21:28
23:50 --> 0:19
1:05 --> 1:35
3:10 --> 3:40
Images attached to this report
Virgo Runs (ER16)
gherardini - 6:56 Thursday 18 April 2024 (64011) Print this report
Operator Report - Night shift
This night the ITF relock was quite difficult with the problem in DC readout locking as already experienced from yesterday, it finally locked at 2:21UTC without doing anything with the excess noise simply disappeared, science mode started at 3:22UTC.

No DMS alerts in the last 8 hours.

- guard tours (UTC):
3:06 --> 3:32
Images attached to this report
Virgo Runs (ER16)
gherardini - 23:04 Tuesday 16 April 2024 (63987) Print this report
Operator Report - Afternoon shift

This afternoon shift was dedicated to commissioning: MIR/MAR reallocation, the work was carried out by Diego, Manuel and Paolo; during the afternoon we collected several fails in LOCKING_DC_READOUT state while opening the B1 PD1 and PD2 photodiode shutters, we succeeded to pass this state only two times, in the evening we called Victor (DET on-call) to investigate this issue, investigation on locking troubles in progress...

Sub-system reports

SBE
at 17:49UTC the SNEB position loop was opened by the guardian, controls properly closed.

Oncall events

DET
(16-04-2024 19:30 - ) From remote
Status: On-going
Description: unlock at DC_READOUT step

Images attached to this report
Virgo Runs (O4b)
gherardini - 23:00 Monday 15 April 2024 (63975) Print this report
Operator Report - Afternoon shift

The ITF kept the lock all the shift, science mode stopped from 15:46UTC to 15:50UTC due to squeezing disengage and from 18:30UTC to 18:40UTC for calibration (hrec check).

- guard tours(UTC):
16:56 --> 17:36
19:01 --> 19:28

Sub-system reports

Calibration
- 18:30UTC: CALIBRATING_DF_DAILY;

Images attached to this report
Virgo Runs (ER16)
gherardini - 14:59 Sunday 14 April 2024 (63962) Print this report
Operator Report - Morning shift
This morning the ITF unlocked once (10:21UTC) because of PR trip, it not saturated the actuation but the ITF unlocked anyhow, relocked at the first attempt; adjusting mode from 7:18UTC to 7:27UTC to reduce the MC IP corrections.

- guard tours (UTC):
5:01 --> 5:39
7:01 --> 7:30
9:06 --> 9:33
11:01 --> 11:40
Images attached to this report
Virgo Runs (ER16)
gherardini - 15:04 Saturday 13 April 2024 (63956) Print this report
Operator Report - Morning shift

The ITF kept the science mode all the shift.

No DMS alerts in the last 8 hours.


-guard tours (UTC):
4:56 --> 5:34
6:56 --> 7:21
11:01 --> 11:28

Sub-system reports

SBE
the SPRB vertical correction is slightly increasing over its threshold, to be recover at the next unlock.

SUSP
one of MC horizontal actuator (H1) is going to saturation.

Images attached to this report
Virgo Runs (ER16)
gherardini - 6:57 Tuesday 09 April 2024 (63892) Print this report
Operator Report - Night shift
ITF relocked and it kept science mode the whole shift.

- guard tours (UTC):
21:20 --> 21:54
23:47 --> 0:17
1:23 --> 1:54
3:10 --> 3:40
Images attached to this report
Virgo Runs (ER16)
gherardini - 6:54 Monday 08 April 2024 (63875) Print this report
Operator Report - Night shift
This night the ITF unlocked from science twice, both of them because of the PR suspension, at the unlock the ITF mode was not stopped automatically remaining science with the ITF unlocked??? I had to remove it by hand, the ITF relocked without problem.

- guard tours (UTC):
21:11 --> 21:39
23:00 --> 23:30
1:00 --> 1:30
3:15 --> 3:45

No DMS alerts in the last 8 hours.
Images attached to this report
Comments to this report:
carbognani - 9:55 Monday 08 April 2024 (63881) Print this report
The problem of not automatic switching out of SCIENCE mode was a (supposed trivial) issue on the ITF_STATUS.py new code put recently in operation. I should have fixed it now. To be checked at the next unlock while in SCIENCE.
carbognani - 16:18 Tuesday 09 April 2024 (63904) Print this report
Last night we had an event of unlock while in SCIENCE and the ITF Mode was correctly immedialety set to PREPARE_SCIENCE. Below the corresponding logs from ITF_STATUS node and attached the corresponding relevant data plots.

2024-04-09-05h59m04-UTC>WARNING-ITF no more locked
2024-04-09-05h59m04-UTC>WARNING-[SCIENCE.run] ezca: V1:GRD-ITF_STATUS_REQUEST => PREPARE_SCIENCE
2024-04-09-05h59m05-UTC>WARNING-[PREPARE_SCIENCE.main] USERMSG 0: itf_mode set to PrepareScience
Images attached to this comment
Virgo Runs (ER16)
gherardini - 23:05 Saturday 06 April 2024 (63867) Print this report
Operator Report - Afternoon shift

The ISC team worked all the afternoon to recover the lock, the ITF had been relocked at LOW_NOISE_3 at 17:22UTC, science mode started at 17:37UTC.

- guard tours (UTC):

17:55 --> 18:30
19:35 --> 20:05

No DMS alerts in the last 8 hours.

Sub-system reports

SBE
at 20:30UTC the SQB2 position control opened by the guardian.

Images attached to this report
Virgo Runs (ER16)
gherardini - 23:03 Friday 05 April 2024 (63856) Print this report
Operator Report - Afternoon shift

In the first part of the afternoon Valerio and Paolo worked on the PR suspension after that the ITF was relocked and the ISC work on SSFS noise injection started, activity completed at 19:00UTC, then I started with the weekly calibrations:

- 19:000TC: Measurement of the TF between CAL and Sc channels (CALIBRATED_DELAY);
- 19:07UTC: Measurement of actuators response for PR and BS mirrors (CALIBRATED_PRWI);
- 20:37UTC: Measurement of actuators response for NI,WI mirrors (CALIBRATED_DF_INtoEND_LN);

Sub-system reports

DAQ
SWEB_Fb crashed and restarted at 19:31UTC.

ISYS
this afternoon after an ITF unlock the PMC pzt correction jumped slightly over its threshold (see plot).

Images attached to this report
Virgo Runs (ER16)
gherardini - 15:02 Thursday 04 April 2024 (63836) Print this report
Operator Report - Morning shift

During this shift the ITF unlocked from science twice, both of them because of the PR suspension, ITF relocked without problem.

Sub-system reports

Air Conditioning
check of ACS equipment:

from 8:30UTC to 9:00UTC west end
from 9:30UTC to 10:00UTC north end

ISC
new etalon set:

- NI from 20.2 to 20.1
- WI from 19.78 to 19.85

Images attached to this report
Virgo Runs (ER16)
gherardini - 15:05 Wednesday 03 April 2024 (63821) Print this report
Operator Report - Morning shift
During this shift the ITF unlocked from science three times, two of them because of the PR suspension, ITF relocked without problem; at 12:07UTC I manually unlocked and Valerio started to work on the PR suspension.
Images attached to this report
AdV-ISC (Commissioning up to first full interferometer lock)
mantovani, gherardini - 14:24 Wednesday 03 April 2024 (63824) Print this report
Etalon 2D scan started

We have launched again the 2D scan for etalon (doubling the time) using Vpm for NI and cm commands for WI @ 12:20UTC.

Comments to this report:
mantovani - 15:04 Wednesday 03 April 2024 (63825) Print this report

stopped again, work in progress by alain

Search Help
×

Warning

×