Reports 1-1 of 1 Clear search Modify search
Injection system (General activities)
derossi, spinicelli, gherardini, melo, francescon - 15:33 Tuesday 03 December 2024 (65698) Print this report
Comment to Increased NEOVAN head temp and PSTAB instability (65661)

To lower the Neovan head temperature we plugged it on a dedicated circuit and chiller (which is also located in the chiller room, borrowed from W. Chaibi).

The Neovan head is shown in photo 1. We closed the two valves connected to the main chiller (photo 2) and connected the Neovan head to the to yellow and green coming from walid's chiller (photo 3 and 4).

The temperature is now stabilized around 26-27 C : the beam is better matched on the PMC (1,5% increase of transmission from the neovan and 5% more in transmission in the PMC) and the rms of the PSTAB has lowered (plot 5)

 

Images attached to this comment
Search Help
×

Warning

Error

The present report has been modified outside this window. Please check for its integrity in the main page.

Refreshing this page will move this report into drafts.

×