PR_TX gain adjustmen

A few of today's unlocks, after the wind settled down, have been caused by low gain oscillation for PR_TX (Fig.1).

Increasing the gain in CARM_NULL_1F caused an unlock soon after the transition, so we introduced a gain change in ACQUIRE_LOW_NOISE_1 (line 5232 and 5275 in ITF_LOCK.py).

The modifications can easily be reverted or made transparent (by simply setting this gain to the same value in CARM_NULL_1F and LOW_NOISE_1) if need be.

Images attached to this report
Comments to this report:
boldrini - 21:31 Monday 22 April 2024 (64064) Print this report

Yesterday's situation has been restored: PR_TX is reset to 2.2 in CARM_NULL_1F and is set to 2.2 as well in LOW_NOISE_1.

The gain change in LOW_NOISE_1 is kept in Metatron's code, but is currently doing nothing.